DETAILS OF ONGOING LINES UNDER TRANSMISSION WEST S Tend. Length Est. cost

Size: px
Start display at page:

Download "DETAILS OF ONGOING LINES UNDER TRANSMISSION WEST S Tend. Length Est. cost"

Transcription

1 DETAILS OF ONGOING LINES UNDER TRANSMISSION WEST S Tend. Length Est. cost Loan (in Work Progress Name of work TWC BOD ETF no No. km crores Cr.) Agency LOI Sch comp Survey Found. Erection Stringing 765 kv s/s Hapur 1 (PPP II) ED %age Prog. Plan /Remarks 220 kv dc Hapur- Dadri Archon/Sa lasar to M/s Salasar on ,firm is in 220 kv dc Hapur- Simbhauli Archon/Sa lasar to M/s Salasar on ,firm is in kv DC line 765KV S/s Gr. Noida - 400KV Gr.Noida (on Quard Conductor) (UP- TD-TRM dtd ) Unitech & R S Infra / 44 86/140 37/140 0/ Foundation & Erection work is in progress. 2. ROW in foundation at loc no (Greator Noida auth.), 23,24,34-42(Yamuna exp. auth.) & 70-75,82,84,86,87,88,8 9 by local farmers *400 kv bays 400 kv s/s Sikandrabad (PPP II) Interconnector of 220 kv dc Sikandaabad 400- Sikandaabad kv s/s Ataur (PPP II) 220 kv LILO Muradnagar- Loni@Ataur 400 kv s/s Dasna GIS (PPP II) 30 TD (along with bay) / ECI /25 28/91 0/91 0/ RS Infra/ Archon /91 0/91 Foundation WIP, firm to immediately take action for starting erection work.the proposed kv Dasna400- Dasna132kV to interconnector DC TD RS Infra / /Archon/S alasar / to M/s Salasar on kv s/s Muradnagar II 400 kv Agra- Muradnagar (Shifting) 400 kv Dadri - Muradnagar (Shifting) Shifting of 220 kv Muradnagar-Loni (II Ckt) line Shifting of 220 kv Muradnagar- Baraut line Shifting of 220 kv Muradnagar- Shamli line 132KV Muradnagar- Muradnagar Railway 2.0 Km on Cable / / / M/s. Ravin Cable, Mumbai (Local) To be constructed Locally. WORK NOT STARTED WORK NOT STARTED WORK NOT STARTED Comp Comp Comp Comp Completed kv s/s Noida sector 123 (GIS)

2 400 KV dc(on monopole) sec 148 Noida to sec123 Noida 132 KV sector 123 (400 KV) Noida to Sec 115 Noida th th 132 KV sector 123 (400 KV) Noida to Sec 66 Noida th 132 KV sector 123 (400 KV) Noida to two unidentified S/S th kv s/s Nehtaur (PPP II) 132KV SC Nehtaur (400)-Chandpur line (On DC Tower) 132KV SC Nehtaur (400)-Bijnaur line (On DC Tower) 132KV SC Nehtaur (400)-Nazibabad line (On DC Tower) 220 kv s/s Dadri (Energised) 132 kv LILO Ghaziabad(IA) - Ghaziabad BS Road@ 220kV Dadri 220 kv s/s Baghpat Archon/Sa lasar Archon/Sa lasar Archon/Sa lasar TD Scantec Comp 22/64 0/64 0/ Field officers requested inumerable time to ascertained feasibility of construction of line in view of severe ROWs without any feedback, matter also reffered to Dir(O) LILO of 220 kv Muradnagar- Shamli TD Trading Comp 15/20 12/20 0/ It was decided by DM to make payment to farmers on pro rata basis of PGCIL compensation which is not tenable, matter taken up by MD, UPPTCL with DM, Bagpat fro resolving.the proposed date of complition kv Baghpat400PG - Baghpat220 (SC on DC towers) TD Trading Comp 45/49 32/49 0/ It was decided by DM to make payment to farmers on pro rata basis of PGCIL compensation which is not tenable, matter taken up by MD, UPPTCL with DM, Bagpat fro resolving.the proposed date of complition kv s/s RC Green 220 Kv DC Gr. Noida- RC Green 4.5 UPPTCL

3 5 220 kv s/s Faridnagar (RNN III) 220 kv SC Dasna400- Faridnagar line on DC tower TD RS Infra/ Archon/ Salasar / / Comp to M/s Salasar on kv s/s Charla (RNN) 220 kv II ckt strg Muzaffarngr400- Modipuram 132 kv sc Charla- Mawana CM M/s. East India [Local Line] TD PNC Comp 45/46 45/ / / Row at Location No 9 (court stay), Advocate changed Line charged from Charla end upto loc 10 on The proposed date of complition is kv s/s Rampur (RNNSAS) 8 LILO of 132 kv Rampur - Bilaspur at 220 kv Rampur 132 kv LILO Moradabad- Rampur@Rampur 132 kv sc Rampur220-Rampur Rly 220 kv s/s Nanauta (Dept) 132 kv sc Nanauta(220)- Gangoh TD ECI Comp 39/40 28/40 0/ Deptt Deptt. TD ECI / (resch) 2/1/08 Comp 67/72 66/72 1/ There is ROW at 1 location(loc no.-1). 2. Field officers are trying to resolve the ROW no. erection gang is working 4. Tree cutting is to be arranged by ETD Rampur. The proposed date of complition is To be Constructed at field Level. 1. Severe ROW at loc 63 & 64, court stay at loc. No Gang reached the site yesterday but no work could be done, effort are being made at field level to resolve ROW. Held up kv s/s Behat (RNNSAS) 220 kv dc Saharanpur PG400- Behat TD PNC Comp 0/10 Profile Submitted. 132 kv sc Behat 220-Pilkhani TD PNC Comp 23/83 3/83 0/ Mass resistance from former forum, No breakthrough despite all out efforts. Revised profile & tower schedule submitted. Low laying area, work shall start after rain. The proposed date of complition kv S/s Hapur 220 KV SC line from 765 KV Hapur KV S/S Hapur on dc tower Archon/Sa lasar

4 LILO of 220 KV Simbhaoli Shatabdi Nagar DC line at 220 kv Hapur ,firm is in 132 kv SC Hapur( 220 KV)- Hapur(132KV) line on DC Tower ,firm is in 132 KV SC Line Babugarh -220kV Hapur on DC Tower ,firm is in 132 kv SC Pilakhuwa - 220kV Hapur on DC Tower ,firm is in kv s/s Madhuvan 220 kv sc Dasna- Madhuvan (on dc tower) / Archon/Sa lasar 220 kv sc Ataur- Madhuvan (on dc tower) / Archon/Sa lasar KV S/S Amroha LILO of 220 KV MBD(220) - Nehtaur(220) SC Amroha / KV DC line Amroha(220)- Agwanpur / kv SC line Amroha(220)-Kothi Khidmatpur on DC Tower /

5 KV SC line Amroha(220)- Bachraun on DC Tower 220 KV S/S Partapur / kV DC Partapur (Jagriti- Vihar)- Hapur(765) Line at 220kV Partapur S/s / Archon No work done, final notice issued to firm 220 KV SC Partapur (Jagriti Vihar) - Meerut(400) PGCIL line on DC Tower Archon/Sa lasar LILO of 132 KV SC Nagli Kithor - Mundali Partapur (Jagriti Vihar) 96 (along 15 with S/s) Engicon and allotted to M/s E on , firm is in process of taking up work. The proposed date of complition is KV DC Partapur(Jagriti Vihar) - Lohiya nagar(hapur road) line 220 KV S/S Chandausi LILO of 220 kv SC Badaun - Sambhal line at 220 KV S/s Chandausi 220 kv s/s Pratap Vihar 220 kv dc Indirapuram-Pratap Vihar Archon/Sa lasar Engicon and allotted to M/s E on , firm is in process of taking up work. The proposed date of complition is kv dc Morti- Pratap Vihar RS Infra Land not finalised. 220 kv sc G Noida400-JPSK sports o/h kv s/s Morti kv sc Morti- Ataur 220 kv Morti- Pratapvihar 132 kv s/s Kirthal (RNN III) Archon/Sa lasar

6 132 kv sc Baraut- Kirthal TD Trading Comp 75/75 75/ / It was decided by DM to make payment to farmers on pro rata basis of PGCIL compensation which is not tenable, matter taken up by MD, UPPTCL with DM, Bagpat fro resolving kv s/s Jehangirpur (RNN III) 132 kv sc Sikandra220- Jahanghirpur TD Trading Comp 111/ / / Row at 11 nos.loc in Chitti Village. However EE, ETD informed that there are only 6-7 ROW which is likely to resolved if gang is deployed. 2.Erection and stringing work stopped due to rain and water logging and standing crop EE ETD informed that Firm has intimated to start work in Oct, kv s/s Noida sec 115 (RNN III) 132 kv lilo Noida 45- Noida Noida kv s/s UPSIDC Masuri (TKSAS) 132 kv sc Dadri- Masuri (UPSIDC) LILO of 132 kv Dasna400- Dasna132@UPSIDC 132 kv s/s Govindpuram (RNN III) 132 kv sc Bapudham- Govindpur TD UPPTCL A.K. Power Trans. Tech. Archon/Sa lasar Comp 26+0/ 47 0/47 0/ TD RS Infra Work hand over to M/s. A K. Power on dated kv sc Madhuvan- Govindpur TD RS Infra kv s/s Tex Centre Pilkhuwa 132 kv sc Faridnagar- Tex Centre Pilkhuwa TD RS Infra Comp 32/43 0/43 0/ ROW being resolved at Local level, Foundation work on gantry complete, Rly Xing case between loc no 5-6 submitted, as intimated by EE, ETD, Ghaziabad because of dispute at loc 7 & 8, work on other locations is stalled. The proposed date of complition is kv Gajraula 132 kv s/s Kothi Khidmatpur 132 kv sc Chajlait220-Kothi Khidmatpur 132 kv s/s Moradabad New (RNNIII) TD RS Infra

7 kv LILO Moradabad- N 132 kv s/s Ramraj (Dept) 132 kv sc Jansath220- Ramraj TD Trading Comp 10 TD Trading Comp 55/63 50/ / ROW on 7 loc no- (8,33,36,37,38,39 &44), being resolved at local level. The proposed kv s/s Poora (TK NKG) 132 sc Khatauli- Poora TD Trading Comp 50/55 40/ / Work held up due to rain and water logging as balance location is parallel to Ganga Canal so water table is high no Foundation & Erection gang each to be deployed by *132 kv bayas@nara&khata uli 132 kv s/s Shamli Shyamla 132 sc Nanauta220- Shamli Shyamla 132 kv Nanauta kv s/s Rampur Maniharan (Dept) 1.67 TD RS Infra Comp 17/88 0/88 0/ Resurvey by firm is U/p due to ROW in original route, survey work is new held up due to sugarcane crop. The proposed date of complition is kv sc Nanauta220- Rampur TD PNC Comp 38/40 38/40 0/ WIP Maniharan 132 bay@nanauta Kv 2 Phase Kota- Tapri Rly Line 132 kv S/S 15 Gangoh 132KV LILO of Roorkee- Saharanpur kv s/s Morna 132kV DC Nehtaur(400) - Morna Line at 132kV S/s Morna (132kV SC on DC Tower Nehtaur (400 kv) Morna Line ) kv S/s Harsia Trading /39 39/39 8.5/ M/s. PSH Archon/Sa lasar Survey Complete d SE & EE has requested DM to provide police force, Local Administration will visit the site today, 'TAHRIR' has been against the farmers creating ROW at local thana (SO Nagal Thana), stringing upto Loc 1 to 26 complete, Loc26-35 under ROW & Loc 35 to Tapri switchyard complete.

8 132kV SC Harsia(Ukawali)- Baghpat(220) Line on DC tower 132kV SC Shingwali- Harsia(Ukawali) Line on DC tower / , firm in in work.the proposed , firm in in work.the proposed kV S/s Mawana Road 132kV DC Charla(220) - Mawana Road Line at 132kV S/s Mawana Road 132kV S/s Kankankhera II 132kV DC Partapur(220) - Kankankhera (II) Line at 132kV S/s kankankhera kv s/s Shahbad 132 kv (sc on dc Towers) Shahbad- Rampur kv s/s Kaniyan LILO of 132 kv Jasala - Nirpura Kaniyan 132kV S/s Hapur By Pass 132kV DC Partapur(220) - Hapur By Pass Line at 132kV S/s Hapur By Pass 132kV S/s Asmoli (Sambhal) Archon Archon Trading /101 0/101 0/ Trading /41 0/41 0/ Archon No work done, final notice issued to firm.the proposed No work done, final notice issued to firm.the proposed Survey complete, and approved 2. FDN WIP (1 gang working, 3 gangs to be deployed in Oct,2015).The proposed date of completion is Survey complete, and approved 2. FDN WIP (1 gang working, 3 gangs to be deployed in Oct,2015).The proposed date of completion is No work done, final notice issued to firm. The proposed Sambhal(220)- Asmoli 132kv DC line World Bank (Expected) firm is in Chandausi(220)- Asmoli 132kv DC line World Bank (Expected) Engicon and allotted to M/s E on firm is in process of taking up work. The proposed date of complition is

9 7 132kV S/s Bhopa kV DC Badaikala - Muzaffarnagar (220) - Bhopa line 220 kv sc G noida400- IT City Gharbara 220 kv sc Badaun- Sambhal 132 sc Moradabad-Bilari 132 sc Bilari- Chandausi 132 kv sc Jehangirabad- Dibai 132 kv sc bet Jehangirabad220 & Jehangirabad- Lakhauti line 132 kv sc Rampur220- Shahjadngr Rly Replacement by ACCC 132 kv sc Muradnagar- Bulandshar Road Replacement by ACCC 132 kv Noida sector 62(220) - Sector 62 (132 KV) 132 kv sc Muzaffarnagar400- Jaroda/ Nara RLY World Bank (Expected) TD MPTL Comp 64/64 64/ / TD Archon Comp 250/ / 250 TD PNC Comp 83/83 78/ / TD PNC Comp 60/60 45/60 6.6/ / Engicon and allotted to M/s E on firm is in process of taking up work. The proposed date of complition is One ckt charged from 220kv RC Green S/s. Balance work held up due to ROW between loc1-18. WIP. Work complete except 12 km. OPGW stringing. WIP Line upto Kundarki LILO point is charge on no Erection gang at site. WIP.The proposed date of complition Er (1gang) & Str (1 gang) WIP loc The proposed date of complition UPPTCL Line not required TD Turn Key TD UPPTCL Comp M/s. PSH (Field Level) Sterlite To be constructed at field Level Comp 25/25 25/ / WIP. Comp (18 km) Apar Comp NA 4.55/ Stringing completed on Shut down to be finalized. Target

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

DETAILS OF ONGOING LINES IN TRANSMISSION SOUTH

DETAILS OF ONGOING LINES IN TRANSMISSION SOUTH Sl. Length Est. cost Work Progress Loan Name of work Tend. No. TWC BOD ETF no km crores (in Cr.) Agency LOI Sch comp Survey Foundation Erection Stringing 1 00 kv s/s Aligarh DETAILS OF ONGOING LINES IN

More information

DETAILS OF ONGOING LINES UNDER TRANSMISSION CENTRAL

DETAILS OF ONGOING LINES UNDER TRANSMISSION CENTRAL DETAILS OF ONGOING LINES UNDER TRANSMISSION CENTRAL 1 400 kv s/s Gonda (PPP I) 220 kv dc Gonda400- Gonda220 DC interconnector 13.45 11.17 Trading Engineers 13.45 03/46 0/46 0/13.45 11.6 1. Stubs & Templates

More information

STUDY OF MOBILITY PLAN IN LIGHT OF UPCOMING METRO RAILWAY IN MEERUT CITY REROUTINGOF CITYBUSROUTES ALLOCATIONOFDEPOTSOFUPSRTCANDMCTSL

STUDY OF MOBILITY PLAN IN LIGHT OF UPCOMING METRO RAILWAY IN MEERUT CITY REROUTINGOF CITYBUSROUTES ALLOCATIONOFDEPOTSOFUPSRTCANDMCTSL Leaders-5 Mid Term Review STUDY OF MOBILITY PLAN IN LIGHT OF UPCOMING METRO RAILWAY IN MEERUT CITY REROUTINGOF CITYBUSROUTES ALLOCATIONOFDEPOTSOFUPSRTCANDMCTSL Authors: SANDEEP LAHA & PARVEZ BASHIR Introduction

More information

Annexure. Technical Details Package 1

Annexure. Technical Details Package 1 Annexure Technical Details Package 1 PACKAGE-1 765 kv S/C Mainpuri-Bara Line with 765 kv/4 kv AIS at Mainpuri and Associated Schemes/Work Scope of work in Substation Sl.No. 1 Name of Substation Type Rating

More information

Presentation on URBAN TRANSPORTATION PLAN FOR MEERUT CITY. Presentation by: Meerut Development Authority

Presentation on URBAN TRANSPORTATION PLAN FOR MEERUT CITY. Presentation by: Meerut Development Authority Presentation on URBAN TRANSPORTATION PLAN FOR MEERUT CITY Presentation by: Meerut Development Authority Meerut City An Overview Historical city - dating back to Ramayana and Mahabharata. In 1806 the cantonment

More information

Draw your kind attention towards the hoarding / unipole list with other detail that s as follow :- WESTERN UTTAR PRADESH REGION

Draw your kind attention towards the hoarding / unipole list with other detail that s as follow :- WESTERN UTTAR PRADESH REGION Draw your kind attention towards the hoarding / unipole list with other detail that s as follow :- WESTERN UTTAR PRADESH REGION 1 )- -: WESTERN U.P. REGION :- ( A )- ( Meerut Khatuali- Muzaffarnagar Devband

More information

Transmission System Bottlenecks & Planning for Mumbai Metropolitan Region

Transmission System Bottlenecks & Planning for Mumbai Metropolitan Region Transmission System Bottlenecks & Planning for Mumbai Metropolitan Region TRANSMISSION GROUP MERC 5 th August 2011 2 Actual Flows for Mumbai Peak FY12 ( 3209 MW) Tie Line Flows (Amp & MW) during Mumbai

More information

Minutes of the 19 th meeting of the Standing committee on transmission system of Northern Region held at Amritsar on 01/10/05.

Minutes of the 19 th meeting of the Standing committee on transmission system of Northern Region held at Amritsar on 01/10/05. Minutes of the 19 th meeting of the Standing committee on transmission system of Northern Region held at Amritsar on 01/10/05. 1. List of the participants is enclosed at Annex - I. Member (PS) CEA welcomed

More information

Additional Agenda for 31 st Standing Committee Meeting of Power System Planning for Northern Region

Additional Agenda for 31 st Standing Committee Meeting of Power System Planning for Northern Region Additional Agenda for 31 st Standing Committee Meeting of Power System Planning for Northern Region a) Power Supply to M/s Noida Power Company Limited (NPCIL) NPCL has applied to CTU for connectivity for

More information

Sl.No. ECONOMIC ACTIVITY Saharanpur Muzaffarnagar Shamli Bijnor Moradabad Sambhal

Sl.No. ECONOMIC ACTIVITY Saharanpur Muzaffarnagar Shamli Bijnor Moradabad Sambhal BY EONOMI TIVITY -202-3 Sl.No. EONOMI TIVITY Saharanpur Muzaffarnagar Shamli Bijnor Moradabad Sambhal 2 3 4 5 6 9 0 2 3 rorers. 26.66 26.99 49.0 53.36 0.0 0.56 0.24 04. 206.45 49.94.6 29.2.66 34.9.4 93.2

More information

MOSDORFER INDIA. Fittings and damping systems for overhead transmission lines

MOSDORFER INDIA. Fittings and damping systems for overhead transmission lines MOSDORFER INDIA Fittings and damping systems for overhead transmission lines Mosdorfer Your first choice in all your transmission line projects! Over 200,000 km overhead transmission lines today is equipped

More information

Sewa Bhawan, R. K. Puram, New Delhi As per List Enclosed-

Sewa Bhawan, R. K. Puram, New Delhi As per List Enclosed- भ रत सरक र / Government of India व य त म लय / Ministry of Power क य व य त धकरण / Central Electricity Authority स व भवन, आर. क. प रम, नई द ल -110066 Sewa Bhawan, R.. Puram, Delhi-110066 ISO: 9001:2008 No.

More information

RFP Corrigendum No. 01

RFP Corrigendum No. 01 RFP Corrigendum 01 The RFP document for selection of Transmission Service provider for the Package- 1 against tender specification ESD-765/4 has been modified to the extent below: S. Clause / Page 1. Definition

More information

Bangladesh s Power Sector : At a Glance

Bangladesh s Power Sector : At a Glance Bangladesh s Power Sector : At a Glance December, 2014 Installed Capacity (MW) : 10,709 De-rated Capacity (MW) : 10,130 Maximum Generation (MW) : 7,418 Total Consumers (in Million) : 15.4 Transmission

More information

CONFERENCE ON TRANSMISSION & DISTRIBUTON MR N C VENUGOPAL TRANSMISSION SECTOR GROWTH & CHALLENGES. DATE 2 ND NOVEMBER 2012

CONFERENCE ON TRANSMISSION & DISTRIBUTON MR N C VENUGOPAL TRANSMISSION SECTOR GROWTH & CHALLENGES. DATE 2 ND NOVEMBER 2012 CONFERENCE ON TRANSMISSION & DISTRIBUTON MR N C VENUGOPAL TRANSMISSION SECTOR GROWTH & CHALLENGES. DATE 2 ND NOVEMBER 2012 TRANSMISSION SECTOR GROWTH HIGHLIGHTS Source - POWERLINE Transmission line length

More information

2. Director (W &P) UPPTCL, Shakti Bhawan Extn,3rd floor, 14, Ashok Marg, Lucknow (Fax: )

2. Director (W &P) UPPTCL, Shakti Bhawan Extn,3rd floor, 14, Ashok Marg, Lucknow (Fax: ) . Member, Secretary, NRPC, 8-A Shajeed Jeet Singh Sansanwal Marg, Katwaria Sarai, New Delhi - 006 (Fax-0-26865206) 4. Director (Technical), Punjab State Transmission Corperation Ltd. (PSTCL) Head Office

More information

Report. the feasibility of

Report. the feasibility of Report on the feasibility of Additional Interconnection between India and Bangladesh Joint Technical Team (JTT) of India and Bangladesh July 2016 Contents 1.0 Background 1 2.0 Additional power export to

More information

Hosur Krishnagiri Project Of NH-7

Hosur Krishnagiri Project Of NH-7 . INSPECTION AND MONITORING OF THE CONSTRUCTION WORKS. PROGRESS UP TO 31st October 2014.1. a. HIGHWAYS - MCW & Service Road Sl Description Unit Total Scope (Km) Completed Percentage achieved % 1 Clearing

More information

2. Director (W &P) UPPTCL, Shakti Bhawan Extn,3rd floor, 14, Ashok Marg, Lucknow (Fax: )

2. Director (W &P) UPPTCL, Shakti Bhawan Extn,3rd floor, 14, Ashok Marg, Lucknow (Fax: ) 1 1. Member, Secretary, NRPC, 18-A Shajeed Jeet Singh Sansanwal Marg, Katwaria Sarai, New Delhi - 110016 (Fax-011-26865206) 4. Director (Technical), Punjab State Transmission Corporation Ltd. (PSTCL) Head

More information

Hosur Krishnagiri Project Of NH-7

Hosur Krishnagiri Project Of NH-7 9. INSPECTION AND MONITORING OF THE CONSTRUCTION WORKS. PROGRESS UP TO 31 May 2015 1a. HIGHWAYS - MCW & Service Road Sl Description Unit Total Scope (Km) Completed Percentage achieved % 1 Clearing & Grubbing

More information

List of the participants is enclosed at Annexure I.

List of the participants is enclosed at Annexure I. Minutes of the 37 th Standing Committee Meeting (SCM) on Power System Planning of Northern Region held on 20 th January, 2016 (Wednesday) at NRPC, New Delhi List of the participants is enclosed at Annexure

More information

-As per List enclosed- 27 th meeting of the Standing Committee on Power System Planning of

-As per List enclosed- 27 th meeting of the Standing Committee on Power System Planning of स खय /No. 1/9/08-SP&PA/ भ रत सरक र/Government of India क य वध त धकरनण/Central Electricity Authority णल आय जन एव पर य जन म य कनण भ ग/SP&PA Division आर क प रम/R.K. Puram नई द ल /New Delhi -110606 [आई आई.एस

More information

HVDC Systems in India

HVDC Systems in India HVDC Systems in India Outline Introduction HVDC Systems presently in operation Main Data/Salient Features Upcoming Projects Future Challenges Transmission Network - Present 765kV/400kV lines: about 1,03,000

More information

Line using HTLS Conductors to increase

Line using HTLS Conductors to increase Upgradation of 132kV Transmission Line using HTLS Conductors to increase the load transfer capacity. By Srikrushna S. Navlakhe Executive Engineer, EHV Construction cum Operation and Maintenance Zone, MSETCL,

More information

SAUDAMINI, Plot No.2, Sector-29, Gurgaon, Haryana Powergrid Corporation of India Ltd., SAUDAMINI, Plot No.2, Sector-29, Gurgaon

SAUDAMINI, Plot No.2, Sector-29, Gurgaon, Haryana Powergrid Corporation of India Ltd., SAUDAMINI, Plot No.2, Sector-29, Gurgaon पत क स च : Sl. Organization Address Tele/Fax No./email No. 1 PGCIL Sh. I S Jha, Chairman & Managing Director, Powergrid Corporation of India Ltd., SAUDAMINI, Plot No.2, Sector-29, Gurgaon, Haryana-122001.

More information

LAYOUT REPORT OF ROOFTOP PROJECT. For 115 kwp. Order No. # Date 13 October, Name of Place California.

LAYOUT REPORT OF ROOFTOP PROJECT. For 115 kwp. Order No. # Date 13 October, Name of Place California. LAYOUT REPORT OF ROOFTOP PROJECT For 115 kwp Name of Place California Client abc Date 13 October, 2014 Email ezysolare@gmail.com Order No. #1410130001 Address xyz Mumbai, Maharashtra, India 000000 INDEX

More information

BRIEF ACHIEVEMENTS AND INITIATIVES OF SIKKIM NATIONALISED TRANSPORT (SNT) (TILL DECEMEBR 2015)

BRIEF ACHIEVEMENTS AND INITIATIVES OF SIKKIM NATIONALISED TRANSPORT (SNT) (TILL DECEMEBR 2015) TRANSPORT DEPARTMENT GOVERNMENT OF SIKKIM YATAYAT BHAWAN, DEVELOPMENT AREA GANGTOK 737101 Ph. No.: 03592-202483(O), 03592-203483(R), Fax No. 03592-203418 Email: secytransport@gmail.com BRIEF ACHIEVEMENTS

More information

Steel In The News. A compilation of leading news items on Indian steel industry as reported in major national dailies. Highlight of the Week 2

Steel In The News. A compilation of leading news items on Indian steel industry as reported in major national dailies. Highlight of the Week 2 Steel In The News A compilation of leading news items on Indian steel industry as reported in major national dailies CONTENTS Page Highlight of the Week 2 Raw Material 2 Company News 3 Projects 4 Steel

More information

Power evacuation system for RAPP Generating Units No. 5,6 (2x220 MW) and 7,8 (2x700 MW).

Power evacuation system for RAPP Generating Units No. 5,6 (2x220 MW) and 7,8 (2x700 MW). Agenda Note For 13 th Standing Committee Meeting of Northern Region Item-I Power evacuation system for RAPP Generating Units No. 5,6 (2x220 MW) and 7,8 (2x700 MW). 1 Introduction 1.1 The following existing

More information

welcome to the BC Hydro community open house

welcome to the BC Hydro community open house welcome to the BC Hydro community open house Dawson Creek/ Chetwynd Area Transmission ProjecT Open House welcome Dawson Creek/Chetwynd Area Transmission Project (DCAT) The purpose of this open house is

More information

TRANSMISSION CAPACITY ADDITION PROGRAMME DURING No. 1 Introduction 1

TRANSMISSION CAPACITY ADDITION PROGRAMME DURING No. 1 Introduction 1 TRANSMISSION CAPACITY ADDITION PROGRAMME DURING 2006-07 Sl. No. Contents Page No. 1 Introduction 1 2 Chapter 1 Transmission Capacity Additions During 2005-06 of 10 th plan period 3 Chapter 2 Construction

More information

Land requirement for depots for augmentation of bus fleet in NCT

Land requirement for depots for augmentation of bus fleet in NCT Land requirement for depots for augmentation of bus fleet in NCT Environment Pollution (Prevention & Control) Authority for Delhi and NCR May 17, 2016 Delhi needs to augment its fleet of buses for public

More information

Dairy Cum Powder Plant

Dairy Cum Powder Plant Profile of Dairy Cum Powder Plant ( a unit of TCMPF Ltd ) Ammapalayam (An ISO 22000 : 2005 FSMS Certified Dairy) The Tamil Nadu Co-Operative Milk Producers Federation Ltd., Chennai - 98 (Regn. No.: MD

More information

SUBSTATION DESIGN TRAINING

SUBSTATION DESIGN TRAINING 2017 SUBSTATION DESIGN TRAINING ADVANCE ELECTRICAL DESIGN & ENGINEERING INSITUTE (Registered under MSME& An ISO 9001:2008 CERTIFIED) Training Centre: Advance Group of Institutions C-1, Second Floor Near

More information

PCDO. Jan Launched portion of Viaduct Deck Structure from S-180 (KATRA- BANIHAL SECTION) Udhampur-Srinagar-Baramulla Rail Link Project

PCDO. Jan Launched portion of Viaduct Deck Structure from S-180 (KATRA- BANIHAL SECTION) Udhampur-Srinagar-Baramulla Rail Link Project PCDO Jan-2018 Launched portion of Viaduct Deck Structure from S-180 (KATRA- BANIHAL SECTION) Udhampur-Srinagar-Baramulla Rail Link Project Northern Railway vuqjkx dqekj lpku vkbzvkj,lb Anurag Kumar Sachan

More information

Inter State Bus Terminal

Inter State Bus Terminal Inter State Bus Terminal Sector 22, Dwarka New Delhi 12 th June, 2008 1 Contents 1. Project Location 2. Location Analysis 3. Traffic Analysis 4. Interpretation of MPD- 2021 5. Conceptual Planning/ Design

More information

RESTRUCTURING PAPER ON A. PROPOSED PROJECT RESTRUCTURING OF MUMBAI URBAN TRANSPORT PROJECT 2A Loan No IN June 29, 2010 TO THE REPUBLIC OF INDIA

RESTRUCTURING PAPER ON A. PROPOSED PROJECT RESTRUCTURING OF MUMBAI URBAN TRANSPORT PROJECT 2A Loan No IN June 29, 2010 TO THE REPUBLIC OF INDIA Public Disclosure Authorized Document of The World Bank Report No: 63374-IN Public Disclosure Authorized Public Disclosure Authorized RESTRUCTURING PAPER ON A PROPOSED PROJECT RESTRUCTURING OF MUMBAI URBAN

More information

(i) Establishment of 400kV Pooling Station at Fatehgarh (with a provision to upgrade at 765kV level)

(i) Establishment of 400kV Pooling Station at Fatehgarh (with a provision to upgrade at 765kV level) Annex-I Corrigendum to Minutes of the 36 th meeting of the Empowered Committee on Transmission held on 26 th July, 2016 at 3:30 PM at Conference Room of CEA, 2 nd Floor, Sewa Bhawan, R.K. Puram, New Delhi

More information

1. Confirmation of the minutes of 19th meeting of the Standing Committee on Transmission system Planning held on at Amritsar, Punjab.

1. Confirmation of the minutes of 19th meeting of the Standing Committee on Transmission system Planning held on at Amritsar, Punjab. Agenda note for 20 th Standing Committee Meeting for planning of transmission system of Northern Region 1. Confirmation of the minutes of 19th meeting of the Standing Committee on Transmission system Planning

More information

Type of Containment Systems in select 30 cities

Type of Containment Systems in select 30 cities Type of Containment Systems in select 30 cities Break up of containment systems 8% 5% 3%2% 1%0% 45% Septic Tank connected to open drain Fully Lined Tank connected to open drain Lined Pit with semi-permeable

More information

:Tamil Nadu Generation and Distribution Corporation Limited: Delegation of powers of sanction to officers (TNEB Volume-II) - revised Communicated Reg

:Tamil Nadu Generation and Distribution Corporation Limited: Delegation of powers of sanction to officers (TNEB Volume-II) - revised Communicated Reg :Tamil Nadu Generation and Distribution Corporation Limited: Delegation of powers of sanction to officers (TNEB Volume-II) - revised Communicated Reg Technical Branch (Per) TANGEDCO Proceedings. (FB) No.

More information

The imperative of controlling vehicle numbers and increasing access: Report on public transport projects in Delhi

The imperative of controlling vehicle numbers and increasing access: Report on public transport projects in Delhi The imperative of controlling vehicle numbers and increasing access: Report on public transport projects in Delhi In Response to the Hon ble Supreme Court Order Dated January 23, 2004 (In the matter of

More information

Sano Milti Khola Hydropower Project, Fulasi VDC, Ramechhap (3 MW)

Sano Milti Khola Hydropower Project, Fulasi VDC, Ramechhap (3 MW) Sano Milti Khola Hydropower Project, Fulasi VDC, Ramechhap (3 MW) Monthly Progress Report Prepared by : Sano Milti Khola Hydropower Limited www.smi.com.np smi.investment.limited@gmail.com Date : June,

More information

UP Electricity Regulatory Commission Vidyut Niyamak Bhawan, Vibhuti Khand, Gomti Nagar, Lucknow. Public Notice

UP Electricity Regulatory Commission Vidyut Niyamak Bhawan, Vibhuti Khand, Gomti Nagar, Lucknow. Public Notice UP Electricity Regulatory Commission Vidyut Niyamak Bhawan, Vibhuti Khand, Gomti Nagar, Lucknow No.UPERC/ Secy/JD(G)/2018/ dated : 20 th August, 2018 Public Notice The Commission is in process of reviewing

More information

Proposed Dounreay - Mybster 275 kv / 132 kv

Proposed Dounreay - Mybster 275 kv / 132 kv Background Scottish Hydro-Electric Transmission Ltd (SHETL) is proposing a new 275 kilovolt (kv) (1 kilovolt = 1000volts) double circuit overhead line (OHL) between the Dounreay sub station and the new

More information

Wessel Bakker Business Line Director ETD BMEA DNV KEMA The Netherlands

Wessel Bakker Business Line Director ETD BMEA DNV KEMA The Netherlands Transmission grid extension for Lake Turkana Wind Farm Wessel Bakker Business Line Director ETD BMEA DNV KEMA The Netherlands wessel.bakker@dnvkema.com Contents Drivers for grid expansion Suswa and Loyangalani

More information

Mohammad Alauddin Deputy Secretary Power Division Ministry of Power, Energy & Mineral Resources Govt. of the People s Republic of Bangladesh

Mohammad Alauddin Deputy Secretary Power Division Ministry of Power, Energy & Mineral Resources Govt. of the People s Republic of Bangladesh Mohammad Alauddin Deputy Secretary Power Division Ministry of Power, Energy & Mineral Resources Govt. of the People s Republic of Bangladesh mohammad_alauddin4124@yahoo.com December 19, 2013 Total area

More information

S P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836

S P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836 FOR OFFICIAL USE ONLY NOT FOR PUBLICATION TENDERER S COPY ORIGINAL COPY T E N D E R S P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836 FOR ERECTION, TESTING, COMMISSIONING TRIAL OPERATION

More information

MINUTES OF THE 47 th SLCF MEETING HELD ON

MINUTES OF THE 47 th SLCF MEETING HELD ON MINUTES OF THE 47 th SLCF MEETING HELD ON 23.11.2016 Shri. Rafikul Islam, Chief Engineer (SLDC), WBSETCL & Chairperson, SLCF welcomed all the participant members to the 47 th SLCF meeting.. ITEM-1: CONFIRMATION

More information

Application for release of capital subsidy on installation of Grid Connected Solar Power Plant

Application for release of capital subsidy on installation of Grid Connected Solar Power Plant Chandigarh Renewal Energy, Science & Technology Promotion Society (CREST) Under the Aegis of Department of Science & Technology, Chandigarh Administration), Paryavaran Bhawan, First Floor, Sec-19B, Madhya

More information

LATEST DEVELOPMENTS IN NEPAL POWER SECTOR INCLUDING THE STATUS OF D-M 400 KV CBTL

LATEST DEVELOPMENTS IN NEPAL POWER SECTOR INCLUDING THE STATUS OF D-M 400 KV CBTL Third Meeting of Taskforce 2, February 25-26, 2015; Colombo, Sri Lanka LATEST DEVELOPMENTS IN NEPAL POWER SECTOR INCLUDING THE STATUS OF D-M 400 KV CBTL Surendra Rajbhandari Chief, Project Management Directorate,

More information

THE PROTEAN AND POC-MAST DESIGN

THE PROTEAN AND POC-MAST DESIGN THE PROTEAN AND POC-MAST DESIGN Contents 1. The changing landscape of generation for power transmission and distribution. 2. The Holford rules and recommendations for OHL routing and design. 3. The current

More information

HT, LT U.G. cables & PVC insulated Al wire

HT, LT U.G. cables & PVC insulated Al wire HT, LT U.G. cables & PVC insulated Al wire Sl.No Name of the firm s particulars Valid upto 1 M/s. Gloster s Ltd., Kallakal(Vi), Toopran(MN), Medak district, Andra Pradesh ( Ph No: 91-80-2372 2274,2837

More information

Thereafter, the agenda items were taken up.

Thereafter, the agenda items were taken up. The Summary record of the 21 st meeting of Standing Committee held at NRPC Conference Room, Katwaria Sarai, Delhi on 03 rd November 2006. (1) List of the participants is annexed. CE SP&PA, CEA welcomed

More information

Total Ex. Tax/VAT. (Rs.) (if any) in Rs. (Bought out/direct) length 587M 226M

Total Ex. Tax/VAT. (Rs.) (if any) in Rs. (Bought out/direct) length 587M 226M ORISSA POWER TRANSMISSION CORPORATION LIMITED Supply & Laying of 132 KV XLPE Double Circuit (4 cable per Circuit including one spare) underground 1000 Sq. mm annealed Copper XLPE EHV Cable with Associated

More information

SUBMISSION TO METROLINK PUBLIC CONSULTATION. From: Eamon Ryan TD Dáil Éireann, Kildare Street, Dublin 2 Date: 8th May 2018

SUBMISSION TO METROLINK PUBLIC CONSULTATION. From: Eamon Ryan TD Dáil Éireann, Kildare Street, Dublin 2 Date: 8th May 2018 SUBMISSION TO METROLINK PUBLIC CONSULTATION From: Eamon Ryan TD Dáil Éireann, Kildare Street, Dublin 2 Date: 8th May 2018 Suggested Route Map including stations Rathmines, Terenure, Rathfarnham INTRODUCTION

More information

Valmont India - Utility UTILITY POLES

Valmont India - Utility UTILITY POLES Valmont India - Utility 1 UTILITY POLES Introduction to Utility Poles 2 Traditionally lattice towers common for high voltage transmission lines. Use of steel poles started in late 1960s in US with extensive

More information

I. Operational Feedback from NLDC:

I. Operational Feedback from NLDC: Additional Agenda of the 37 th Standing Committee Meeting (SCM) on Power System Planning of Northern Region to be held on 20.1.2016 (Wednesday) at 10:30 A.M. at NRPC conference Room, NRPC Katwaria Sarai,

More information

Need Assessment Document (NAD) DDUGJY

Need Assessment Document (NAD) DDUGJY Need Assessment Document (NAD) DDUGJY Index SNo. Details Page No. 1.0 General Instruction 3 2.0 Objectives of DDUGJY 5 3.0 Scope of works 7 4.0 General information of project area 10 5.0 Details of existing

More information

T&D EQUIPMENT MARKET IN INDIA 2017

T&D EQUIPMENT MARKET IN INDIA 2017 New Research Report T&D EQUIPMENT MARKET IN INDIA 2017 Demand Outlook and Projections (till 2021-22) Report (PDF) Data-set (Excel) India Infrastructure Research T&D Equipment Market in India 2017 Table

More information

Procurement Plan. Eskom Holdings SOC Limited. Eskom Investment Support Project

Procurement Plan. Eskom Holdings SOC Limited. Eskom Investment Support Project Public Disclosure Authorized Public Disclosure Authorized Public Disclosure Authorized Public Disclosure Authorized General. Project information Country: Borrower: Loan number: Project Implementation Agency

More information

Evacuation system from Chamera III HEP (231 MW).

Evacuation system from Chamera III HEP (231 MW). Agenda for 16 th Meeting of the Standing Committee on Transmission System Planning in Northern Region Item I Evacuation system from Chamera III HEP (231 MW). The Chamera III project would be located in

More information

DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED. (A Govt of West Bengal Enterprise)

DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED. (A Govt of West Bengal Enterprise) DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED (A Govt of West Bengal Enterprise) CHIEF ENGINEER (PROCUREMENT), VIDYUT BHAVAN NOTICE INVITING TENDERS For CONSTRUCTION

More information

Babcock International Group

Babcock International Group P10101 400kV TD Beauly Denny Route New Overhead Line Bird Flight Diverter Schedule 48 Fibre OPGW (Keziah) Earthwire Drawing No. P10101/3105 Pages 1 13 inclusive Document Author: P. Ransome Signature: P.

More information

HVDC MATIARI -LAHORE TRANSMISSION PROJECT ABDUR RAZZAQ CHEEMA, EX-GENERAL MANGER (GRID SYSTEM CONSTRUCTION PROJECTS) NTDC

HVDC MATIARI -LAHORE TRANSMISSION PROJECT ABDUR RAZZAQ CHEEMA, EX-GENERAL MANGER (GRID SYSTEM CONSTRUCTION PROJECTS) NTDC HVDC MATIARI -LAHORE TRANSMISSION PROJECT ABDUR RAZZAQ CHEEMA, EX-GENERAL MANGER (GRID SYSTEM CONSTRUCTION PROJECTS) NTDC SEQUENCE OF PRESENTATION OVERVIEW GENERATION PROPOSED IN SOUTH (2011) EVACUATION

More information

APPENDIX C FACILITY ILLUSTRATION

APPENDIX C FACILITY ILLUSTRATION APPENDIX C FACILITY ILLUSTRATION 21m 21m 21m 0m 5.4m 3.5m access road (allow for water management on sides) Future Expansion 20m 24.5m 61m 49m 69m 20m Future Expansion 5m 100m 4.3m 9m 100m Space for MV

More information

TABLE OF CONTENTS FIGURES: MAP EXHIBITS: TABLES:

TABLE OF CONTENTS FIGURES: MAP EXHIBITS: TABLES: TransWest Express Transmission Project TABLE OF CONTENTS 7.0 DESIGN OPTIONS... 7-1 7.1 OVERVIEW OF DESIGN OPTIONS... 7-1 7.2 DESIGN OPTIONS PURPOSE AND NEED AND DESIGN CHARACTERISTICS... 7-4 7.2.1 Design

More information

HARYANA POWER GENERATION CORPORATION LIMITED Regd. Office C-7, Urja Bhawan, Sector-6, Panchkula Corporate Identity Number: U45207HR1997SGC033517

HARYANA POWER GENERATION CORPORATION LIMITED Regd. Office C-7, Urja Bhawan, Sector-6, Panchkula Corporate Identity Number: U45207HR1997SGC033517 HARYANA POWER GENERATION CORPORATION LIMITED Regd. Office C-7, Urja Bhawan, Sector-6, Panchkula Corporate Identity Number: U45207HR1997SGC033517 Website: www.hpgcl.org.in E-mail- ceplg@hpgcl.org.in EXPRESSION

More information

FINANCIAL HIGHLIGHTS AND BUDGET ESTIMATES

FINANCIAL HIGHLIGHTS AND BUDGET ESTIMATES FINANCIAL HIGHLIGHTS AND BUDGET ESTIMATES A) The summarized actual income and expenditure for the financial year 2014-2015 are as under :- (Rs. in Crores) *Electric Supply *Transport Whole Undertaking

More information

भ त क Government of India ववद य त म त र लय Ministry of Power उत त क ष त र य ववद य त वमवत Northern Regional Power Committee. -sd-

भ त क Government of India ववद य त म त र लय Ministry of Power उत त क ष त र य ववद य त वमवत Northern Regional Power Committee. -sd- भ त क Government of India ववद य त म त र लय Ministry of Power उत त क ष त र य ववद य त वमवत Northern Regional Power Committee.-उक ष वव /प रच लन/106/01/2017/13783-823 ददन क: 13.12.2017 ववषय: प रच लन मन वय

More information

BaartaIya iva&aana isaxaa EvaM AnausaMDaana samstaana paunao

BaartaIya iva&aana isaxaa EvaM AnausaMDaana samstaana paunao BaartaIya iva&aana isaxaa EvaM AnausaMDaana samstaana paunao INDIAN INSTITUTE OF SCIENCE EDUCATION AND RESEARCH PUNE Dr. Homi Bhabha Road, Pune : 411 008 Date: December 21, 2015 TENDER FOR TRANSPORT SERVICES

More information

CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR.

CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR. AMENDMENT-02 TO TECHNICAL SPECIFICATION FOR ELEVATOR (SPEC NO. PE-TS-408-502-A001) 1x800 MW WANAKBORI STPP. CORRIGENDUM/ ADDENDUM 09 ADDITIONAL REQUIREMENT OF ELEVATOR. CL. NO. 2.0 Scope of equipment supply

More information

Intra-State Availability Based Tariff (ABT)

Intra-State Availability Based Tariff (ABT) Intra-State Availability Based Tariff (ABT) What is ABT? 1. In Year 2000, the CERC revised the tariff structures of inter- state generators from drawal-based tariffs to ABT to discipline grid operations.

More information

Tackling Power Theft through Meter Data Management and Quality Analysis. Results from NPCL s AMR roll out and AMI trial

Tackling Power Theft through Meter Data Management and Quality Analysis. Results from NPCL s AMR roll out and AMI trial Tackling Power Theft through Meter Data Management and Quality Analysis Results from NPCL s AMR roll out and AMI trial R. C. Agarwala 23 rd May 2013 NOIDA POWER COMPANY LIMITED Greater Noida, India 1 NPCL:

More information

IGI AIRPORT (T-3)-INTER STATE (NON-AC TAXI)

IGI AIRPORT (T-3)-INTER STATE (NON-AC TAXI) NOTE:- IGI AIRPORT (T-3)-INTER STATE (NON-AC TAXI) 1. Fare Rs.14/- per kilometer. 2. Night charge 25% of the fare (11.00 PM to 5.00 AM) 3. Baggage Rs.10/- per piece (except shopping bag and small briefcase)

More information

POWERING THE NEW WORLD WITH THE INDIA POWER FACTOR

POWERING THE NEW WORLD WITH THE INDIA POWER FACTOR POWERING THE NEW WORLD WITH THE INDIA POWER FACTOR WELCOME GRID EXPANSION AND CONFIGURATION amrehba sisswène Woezor Ahlan Wa Sahlan Akwaba boyeyi bolamu Karibu Dalal ak diam welkom NAMASTE Presentation

More information

PUNJAB STATE POWER CORPORATION LIMITED REPORT ON OUTCOMEOF THE MOCK TRIALSFOR DESIGN OF TWO PART TARIFF

PUNJAB STATE POWER CORPORATION LIMITED REPORT ON OUTCOMEOF THE MOCK TRIALSFOR DESIGN OF TWO PART TARIFF PUNJAB STATE POWER CORPORATION LIMITED REPORT ON OUTCOMEOF THE MOCK TRIALSFOR DESIGN OF TWO PART TARIFF JANURAY, 2014 TABLE OF CONTENTS A1: APPROACH OF TWO PART TARIFF PROPOSAL 3 A2: APPROACH AND METHODOLOGY

More information

Transmission Lines Completed During FY As on 31-Jan-2018

Transmission Lines Completed During FY As on 31-Jan-2018 Transmission Lines Completed During FY- 2017-18 As on 31-Jan-2018 Voltage Level (kv) Name of Transmission Lines Circuit Type Executing Agency Line Length (ckm) Month of Completion 1. 2. 3. 4. 5. 6. 765

More information

+91-8048571184 UB Exim Private Limited http://www.ubexim.in/ We are amongst the leading exporters, manufacturers, suppliers and traders, of this highly commendable and diverse range of Electrical Spares

More information

DETAILS OF THE EXPRESSION OF INTEREST(EOI) NO.: PL.G03.EOI

DETAILS OF THE EXPRESSION OF INTEREST(EOI) NO.: PL.G03.EOI DETAILS OF THE EXPRESSION OF INTEREST(EOI) NO.: PL.G03.EOI.09.001 Date: 29/05/2009 For Annual Operation and Maintenance Service Contract of HT/LT Panels,Motors,Transformers,UPS,Air Conditiners,Lightings

More information

Appendix Item Addendum

Appendix Item Addendum Addendum to ESAH Version 3 Supply Application Appendix Item Addendum 1 Electrical System Item 1.4.5 Short Circuit Ratings Addendum for type of short circuit rating for system voltage of 275kV. 2 Types

More information

WOLVERINE TO BHP JANSEN NEW TRANSMISSION LINE PROJECT FALL 2017

WOLVERINE TO BHP JANSEN NEW TRANSMISSION LINE PROJECT FALL 2017 WOLVERINE TO BHP JANSEN NEW TRANSMISSION LINE PROJECT FALL 2017 TODAY WE LL TALK ABOUT Our challenges and how we re meeting them Why we re building this project Our planning process and considerations

More information

System Improvement Scheme(R&M) : FY

System Improvement Scheme(R&M) : FY GUJARAT ENERGY TRANSMISSION CORPORATION LTD System Improvement Scheme(R&M) : FY 2012-13 In GETCO network, large number of substations and lines are quite old, some of its equipments viz. CT s, PT s, Breakers,

More information

PROPINSIGHT A Detailed Property Analysis Report

PROPINSIGHT A Detailed Property Analysis Report PROPINSIGHT A Detailed Property Analysis Report 40,000+ Projects 10,000+ Builders 1,200+ Localities Report Created On - 7 Oct, 2015 Price Insight This section aims to show the detailed price of a project

More information

Welcome. Green Line in Your Community

Welcome. Green Line in Your Community Welcome Green Line in Your Community Today's session will provide you with information about Administration's recommendation for connecting the Green Line in the Beltline to Victoria Park and Inglewood/Ramsay

More information

TRIANGULO ALIMENTOS LTDA

TRIANGULO ALIMENTOS LTDA Particulars About Your Organisation Organisation Name TRIANGULO ALIMENTOS LTDA Corporate Website Address www.trianguloalimentos.com.br Primary Activity or Product Processor and/or Trader Related Company(ies)

More information

Supplemental Report on the NCTPC Collaborative Transmission Plan

Supplemental Report on the NCTPC Collaborative Transmission Plan Supplemental Report on the NCTPC 2007-2017 Collaborative Transmission Plan May 16, 2008 1 Table of Contents I. Executive Summary...1 II. Richmond-Fort Bragg Woodruff Street 230 kv Line...2 II.A. Need for

More information

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA - 390 007 TENDER FOR Design,Engineering, manufacturing, supply, erection, testing & commissioning of 66

More information

Comidas Holdings 5 B.V.

Comidas Holdings 5 B.V. Particulars About Your Organisation 1.1 Name of your organization Comidas Holdings 5 B.V. 1.2 What is/are the primary activity(ies) or product(s) of your organization? Oil Palm Growers Palm Oil Processors

More information

Seventh Regional Environmentally Sustainable Transport (EST) Forum (23-25 April 2013, Bali,Indonesia)

Seventh Regional Environmentally Sustainable Transport (EST) Forum (23-25 April 2013, Bali,Indonesia) Seventh Regional Environmentally Sustainable Transport (EST) Forum (23-25 April 2013, Bali,Indonesia) Country Report : NEPAL 5/1/2013 1 Initiation in better maintenance of vehicles Systematic Air Quality

More information

IFFCO Pakistan Pvt. Ltd.

IFFCO Pakistan Pvt. Ltd. Particulars About Your Organisation Organisation Name IFFCO Pakistan Pvt. Ltd. Corporate Website Address http://www.iffco.com Primary Activity or Product Manufacturer Related Company(ies) Membership Membership

More information

National Conference on Latest Trends in Design & Testing of Transmission Line Components

National Conference on Latest Trends in Design & Testing of Transmission Line Components Book-Post National Conference on Latest Trends in Design & Testing of Transmission Line Components 22-23 November 2010 To, Mr. M. Selvaraj Engineering Officer / Co-ordinator Mechanical Engineering Division

More information

2681-IND: Bihar Power System Improvement Project

2681-IND: Bihar Power System Improvement Project Invitation for Bids (Please refer to Corrigendum 1 IFB, published on 20 October 2015) Date: 22 September 2015 Loan No. and Title: 2681-IND: Bihar Power System Improvement Project Contract Nos. Deadline

More information

NATIONAL CAPITAL REGION (NCR) 3 To Alwar Bahadurgarh New Delhi Railway Station Jhajjar KMP Expressway Indira Gandhi International Airport ISBT Kashmere Gate NH8 Delhi CBD New Delhi ISBT Sarai Kale Khan

More information

MD, PTCUL welcomed the participants and expressed his happiness for the opportunity of holding the meeting of the Standing Committee in Uttrakhand.

MD, PTCUL welcomed the participants and expressed his happiness for the opportunity of holding the meeting of the Standing Committee in Uttrakhand. Minutes of the Meeting of the 26 th Standing Committee on power system planning of Northern Region held on 13 th October 2008 at Chamba, Uttrakhand List of the participants is at Annex-I. (i) MD, PTCUL

More information

Rail Safety and Standards Board

Rail Safety and Standards Board Rail Safety and Standards Board Certificate of Derogation from a Railway Group Standard (under 8.3 of the Railway Group Standards Code) Derogation Number: Applicant: Subject Matter of Derogation: RGS Number:

More information

INTERCONNECTION REQUIREMENTS INVERTER-BASED DISTRIBUTED GENERATION SOURCES FOR SINGLE-PHASE CUSTOMER SERVICES

INTERCONNECTION REQUIREMENTS INVERTER-BASED DISTRIBUTED GENERATION SOURCES FOR SINGLE-PHASE CUSTOMER SERVICES INTERCONNECTION REQUIREMENTS INVERTER-BASED DISTRIBUTED GENERATION SOURCES FOR SINGLE-PHASE CUSTOMER SERVICES 3. Definitions ( cont'd) Parallel System: A generating facility that is electrically interconnected

More information

GOVERNMENT OF INDIA MINISTRY OF ROAD TRANSPORT & HIGHWA YS

GOVERNMENT OF INDIA MINISTRY OF ROAD TRANSPORT & HIGHWA YS GOVERNMENT OF INDIA MINISTRY OF ROAD TRANSPORT & HIGHWA YS Parivahan Bhavan, 1, Parliament Street, New Delhi-11 0001 RW-NH-350721112010-S&R(B) Dated: 2dh May, 2014 1. The Chief Secretaries of all State

More information

1. Operational Feedback on Transmission Constraint: January 2015 & October Description of the. Antecedent constraints Conditions

1. Operational Feedback on Transmission Constraint: January 2015 & October Description of the. Antecedent constraints Conditions Additional Agenda note for 36 th Standing Committee Meeting on Power System Planning in Northern Region. 1. Operational Feedback on Transmission Constraint: January 2015 & October 2014 S. Corridor Season/

More information

SELECTION OF TRACTION SYSTEMS & ENERGY CONSERVATION IN METRO SYSTEMS. BY BRIJESH DIXIT MANAGING DIRECTOR Nagpur Metro Rail Corporation Ltd.

SELECTION OF TRACTION SYSTEMS & ENERGY CONSERVATION IN METRO SYSTEMS. BY BRIJESH DIXIT MANAGING DIRECTOR Nagpur Metro Rail Corporation Ltd. SELECTION OF TRACTION SYSTEMS & ENERGY CONSERVATION IN METRO SYSTEMS BY BRIJESH DIXIT MANAGING DIRECTOR Nagpur Metro Rail Corporation Ltd. ALTERNATIVES TRACTION SYSTEMS AC Traction DC Traction 25 KV 50