Controllable Lighting

Size: px
Start display at page:

Download "Controllable Lighting"

Transcription

1 Controllable ighting Fluorescent Energy Management / Dimming s and Controls The effective dimming of fluorescent lights delivers a wide range of benefits: greater control of workspace lighting, ability to create a mood, energy savings, and more. Universal ighting Technologies ( Universal ) line of electronic dimming ballasts and controls lets you accomplish these goals with a variety of products to suit your dimming needs. From light level switching and analog dimming to digital dimming and controls, Universal has the products and technologies to meet today s dimming requirements for energy savings and controllable lighting.

2 Product Overview Universal offers five different families of dimming products that can be used for today s dimming requirements for architectural lighting control and energy management applications: BallaStar: Step-dimming SuperDim: Analog (0 to 10 volt) dimming DaliPRO: Digital dimming with the I protocol VariPRO: Parallel-lamp analog dimming evelpro: Parallel-lamp step dimming BallaStar ight evel Switching (S30 & S50) Our ar line offers two options of light level switching (either 100/50% or 100/60/30%). That makes BallaStar a cost-effective solution for both new construction and retrofits. Universal BallaStar ballasts are designed to ensure optimum lamp performance. Their amp Current Crest Factors are well below the maximum 1.7 ASI standard and they start the lamps according to ASI recommendations at all dimming levels. Both of these important design parameters ensure optimum lamp performance. In addition, BallaStar ballasts actually increase cathode heating when dimming to maintain the cathode s proper temperature, which enhances lamp life and performance stability. 1, 2, & 3 lamp models for & volt Switches to preset light levels, keeping all lamps illuminated Eliminates the dark spots associated with inboard/outboard configurations Connects with two line voltage power leads Wires the same as an inboard/outboard fixture o special controls required; uses two wall switches Meets all ASHRAE 90.1 and California Title 24 requirements for lighting control THD <10% ower installed costs; less wiring and equipment required ar ight evel Switching for ultimate control. PAGE 2-10 FOR MORE IFORMATIO CA

3 Product Overview SuperDim Analog Dimming s Universal ighting s new SuperDim analog dimming ballasts are a cost-effective choice for large scale dimming applications. SuperDim ballasts are designed for T8 and T5 linear fluorescent lamps and T4 4-pin quad and triple compact fluorescent lamps. SuperDim ballasts are compatible with a wide range of 0 10 volt controls and can be connected to photocells for daylight harvesting. The resulting energy savings makes it easy to adhere to even the strictest energy requirements, including California Title 24 and ASHRAE These versatile ballasts offer programmed rapid start technology for longer lamp life. They also incorporate end-of-lamp-life shutdown circuits, low profile designs and < 10% THD at full bright. Features and Benefits Ideal for T8 and T5 linear fluorescent lamps and T4 4-pin quad and triple compact fluorescent lamps Compatible with most 0 10 volt manufactured controls Daylight harvesting options with photocells for maximum energy savings Programmed rapid start technology maximizes lamp life ow profile design for fixture design flexibility End-of-lamp-life shutdown circuitry ensures safe operation < 10% THD at full bright Universal input voltage ( volts) for installation flexibility PAGE 2-11 FOR MORE IFORMATIO CA

4 Product Overview DaliPRO TM Digital Dimming s for I DaliPRO TM ballasts from Universal ighting let you take full advantage of the Digital Addressable ighting Interface (I) standard...and that means greater flexibility, greater savings. The I Advantage The I protocol uses a 2-wire control loop to communicate with up to 64 ballasts. Broadcast, group and individual addressing is used to control light levels, recall scenes and poll ballast status. Many I-compatible controls are now available from established manufacturers; and new varieties are being developed daily. DaliPRO Features and Benefits Available for T8, T5, T5HO and compact fluorescent lamps Offers status/performance data, including lamp status ow profile designs for easy installation in a wide variety of fixtures Universal input voltage ( volts) Installer-friendly; ensures you have the right ballast every time uces inventory costs and requirements End-of-amp ife Shutdown with auto reset circuitry for safe operation Programmed Rapid Start for long lamp life PAGE 2-12 FOR MORE IFORMATIO CA

5 Product Overview VariPRO & evelpro Parallel-amp Dimming s Universal ighting Technologies parallel-lamp dimming families combine new performance features with maximum energy savings. These ballasts provide parallel-lamp operation when one lamp fails the other remains lit. This prevents fixture from going dark and simplifies troubleshooting and maintenance operations. Performance Total Harmonic Distortion (THD) < 10% Power Factor (PF) > 10% EMA Premium RoHS Compliant General Features and Benefits Quick Programmed Start Technology Start time less than 700ms Maintains long lamp life in frequently switched applications High Efficiency Operation Complies with CEE Incorporates Anti-Striation circuitry Designed for use with 30, 28, and 25 Watt energy saving lamps True Parallel-amp Operation When one lamp fails, other lamps continue to operate normally Simplifies fixture troubleshooting Universal Input Voltage and 347 Models VariPRO Features and Benefits Analog (0-10V) Dimming Control Compatible with industry standard 0-10V controls and photocells Ideal for daylight harvesting evelpro Features and Benefits ine Voltage Step Dimming Control Uses standard wall switches Provides even fixture illumination TM PAGE 2-13 FOR MORE IFORMATIO CA

6 Application And Operating Information Although dimming ballasts follow similar installation and operating guidelines as electronic ballasts, application notes and other training materials, written specifically for dimming ballasts, are provided on website. SAFETY Analog dimming ballasts are controlled by using a low voltage 0-10VDC control circuit. Care should be taken to insure that the line voltage (AC) wires are not connected to the low voltage DC wires. SuperDim Electronic dimming ballasts have a protection circuit that will sense if the ballast has been connected in this manner and not harm the ballast. ight evel Switching Installation ote The two power leads for the light level switching ballasts must be connected to the same power circuit. The leads should connect to separate switches or relays for control of the light level switching operation. Connection of the input leads to separate power circuits can damage the ballasts. ote: Do not connect any other ballast to the load side of the switches controlling the switched dimming ballast. Compatible Dimming Controls For a listing of compatible controls for universal analog ballasts, please consult catalog page 2-15, or call or check out the Dimming and Controls section of our home page at Fusing Class P ballasts do not require fusing. Fusing can be used when a single circuit has a large number of fixtures/ballasts. For a comprehensive list of appropriate fuses, contact our Technical Engineering Services (TES) Department at. Detailed Operating Instructions For additional information on all of Universal s dimming products, consult our website at Application notes, dimming brochures and online training is available PAGE 2-14 FOR MORE IFORMATIO CA

7 Controls For Analog Dimming s Manual Controls, Photo-Sensors, Wall Stations & Hand Held Remotes Manufacturer Website Telephone Cooper Controls (800) DimOnOff (418) Douglas ighting Controls, Inc (604) HUT Dimming (970) ehigh Electric Products Co. (610) eviton utron (888) UTRO1 - Sales (800) Technical Support exight (218) The Watt Stopper, Inc (800) Marlin Controls (800) Sensor Switch, Inc. (800) (800) PASSIVE Touch-Plate ighting Controls (260) Occupancy Sensors Manufacturer Website Telephone Cooper Controls (800) DimOnOff (418) Douglas ighting Controls, Inc (604) ehigh Electric Products Co. (610) utron (888) UTRO1 - Sales (800) Technical Support exight (218) Marlin Controls (800) Sensor Switch, Inc. (800) (800) PASSIVE Touch-Plate ighting Controls (260) Systems: Control Panels, Building Management Systems, etc Manufacturer Website Telephone DimOnOff (418) Douglas ighting Controls, Inc (604) Cooper Controls (800) HUT Dimming (970) ehigh Electric Products Co. (610) eviton utron (888) UTRO1 - Sales (800) Technical Support exight (218) The Watt Stopper, Inc (800) Marlin Controls (800) Touch-Plate ighting Controls (260) The information listed above is provided by Universal ighting Technologies to facilitate development of dimming systems. All information has been provided by the controls manufacturers, and Universal ighting Technologies makes no guarantee regarding its accuracy. The reader is advised to contact these, and other manufacturers of analog dimming systems, to obtain application advice, to determine availability of the controls listed above, and to learn about other controls that may be offered. Data is subject to change without notice. PAGE 2-15 FOR MORE IFORMATIO CA

8 DaliPRO DaliPRO DIMMIG BAASTS amp Qty. Starting Method F1728 F32T8 * F14T5 F21T5 ine Volts STARTIG METHOD EGED PAR-PRS = Parallel Programmed Start Catalog umber Input Current (Amps) Input Power (Watts) B132PUVDV3-A B232PUVDV3-A B132PUVDV3-A B232PUVDV3-A B114PUVDV3-D B214PUVDV3-D B128PUVDV3-D B228PUVDV3-D Power Factor (PF) Factor (BF) Efficacy Factor (BEF) THD % Min. F/C Start Temp Wiring Diag Dim. > <10% 32/0 1 -A > <10% 32/0 2 -A > <10% 32/0 1 -A > <10% 32/0 2 -A > <10% 50/10 1 -D > <10% 50/10 2 -D > <10% 50/10 1 -D > <10% 50/10 2 -D F28T5 * B128PUVDV3-D > <10% 50/10 1 -D B228PUVDV3-D > <10% 50/10 2 -D F54T5HO* B254PUDV3PD B254PUDV3PD > < 10% 32/0 32/ D -D B254PUDV3PD B254PUDV3PD > < 10% 32/0 32/ D -D CFQ13W/G24q C213UVDV3ME > <15% 32/0 3 -ME C213UVDV3ME > <15% 32/0 4 -ME CFQ18W/G24q C218UVDV3ME > <10% 32/0 3 -ME C218UVDV3ME > <10% 32/0 4 -ME CFQ26W/G24q C226UVDV3ME > <10% 32/0 3 -ME C226UVDV3ME > <10% 32/0 4 -ME CFTR32W/G24q C226UVDV3ME > <10% 32/0 3 -ME CFTR42W/G24q C226UVDV3ME > <10% 0/-18 3 DP2 * Consult Specification Sheets at for additional lamp applications See page 2-22 for Dimensions and Wiring Diagrams PAGE 2-16 FOR MORE IFORMATIO CA

9 SuperDim 0-10V DIMMIG BAASTS Please visit for the most up to date status and recent changes to the SuperDim product family. SuperDim 0-10V DIMMIG STARTIG METHOD EGED PRS = Programmed Rapid Start amp ine Input Power Min. F/C Starting ine Catalog Current Power Factor Factor THD Start Wiring Qty. Method Volts umber (Amps) (Watts) (PF) (BF) % Temp Diag. Dim. F17T B132PUVSV3-A > <10 50/10 7 -A B232PUVSV3-A > <10 50/10 8 -A F25T B132PUVSV3-A > <10 50/10 7 -A B232PUVSV3-A > <10 50/10 8 -A F32T B132PUVSV3-A > <10 50/10 7 -A B232PUVSV3-A > <10 50/10 8 -A F14T B114PUVSV3-D > <10 32/0 7 -D B214PUVSV3-D > <10 32/0 8 -D F21T B128PUVSV3-D > <10 50/10 7 -D B228PUVSV3-D > <10 50/10 8 -D F28T B128PUVSV3-D > <10 50/10 7 -D B228PUVSV3-D > <10 50/10 8 -D F35T B135PUVSV3-D > <10 50/10 7 -D CFQ13W/G24q & CFTR13W/Gx24q C213UVSV3ME > <15 32/0 9 C C213UVSV3ME > <10 32/0 10 C11 CFQ18W/G24q & CFTR18W/Gx24q C218UVSV3ME > <10 32/0 9 C C218UVSV3ME > <10 32/0 10 C11 CFQ26W/G24q & CFTR26W/Gx24q C226UVSV3ME > <10 32/0 9 C C226UVSV3ME > <10 32/0 10 C11 CFTR32W/Gx24q C226UVSV3ME > <10 32/0 9 C11 CFTR42W/Gx24q C226UVSV3ME > <10 32/0 9 C11 See page 2-22 for Dimensions and Wiring Diagrams PAGE 2-17 FOR MORE IFORMATIO CA

10 BallaStar 0-10V DIMMIG BallaSTAR 0-10 VOT DIMMIG BAASTS FOR (1), (2), (3) & (4) T8 AMPS Please visit for the most up to date status and recent changes to the ar 0-10V product family. Analog Dimming Rapid Start 1, 2, 3 & 4 amp Applications amp ine Input Power Min. F/C Starting ine Catalog Current Power Factor Factor Efficacy THD Start Wiring Qty. Method Volts umber (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. F25T8 - One amp Applications % > < 10 50/10 7 ST 5% > < 30 50/10 7 ST F32T8 - One amp Applications % > < 10 50/10 7 ST 5% > < 20 50/10 7 ST F32T8 - Two amp Applications 2 RS % > < 10 50/10 8 ST 5% > < 15 50/10 8 ST F32T8 - Three amp Applications 3 SER-RS 100% > < 10 50/10 17 ST 5% > < 10 50/10 17 ST 100% > < 10 50/10 17 ST 5% > < 15 50/10 17 ST F32T8 - Four amp Applications 4 SER/PAR-RS All models except B232SR347V5 are cuus isted B232SR347V5 is CSA Certified 100% > < 10 50/ ZZ 5% > < 15 50/ ZZ See page 2-22 for Dimensions and Wiring Diagrams IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start STARTIG METHOD EGED PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start PAGE 2-18 FOR MORE IFORMATIO CA

11 BallaSTAR STEP DIMMIG BAASTS FOR (1), (2) & (3) T8 AMPS Step Dimming Rapid Start 1-3 amp Applications BAASTAR IGHT EVE SWITCHIG amp ine Input Power Min. F/C Starting ine Catalog Current Power Factor Factor Efficacy THD Start Wiring Qty. Method Volts umber (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. F17T8 - One amp Applications 100% > < 15 32/0 11 -A 50% > < 15 32/0 11 -A 100% > < 15 32/0 11 -A 50% > < 15 32/0 11 -A F17T8 - Two amp Applications 100% > < 10 32/0 12 -A 50% > < 15 32/0 12 -A 100% > < 10 32/0 12 -A 50% > < 15 32/0 12 -A F25T8 - One amp Applications 1 RS 100% > < 10 32/0 11 -A 50% > < 10 32/0 11 -A 100% > < 10 32/0 11 -A 50% > < 10 32/0 11 -A F25T8 - Two amp Applications 2 SER-RS 100% > < 10 32/0 12 -A 50% > < 10 32/0 12 -A 100% > < 10 32/0 12 -A 50% > < 10 32/0 12 -A F32T8 - One amp Applications 1 RS 100% > < 10 32/0 11 -A 50% > < 10 32/0 11 -A 100% > < 10 32/0 11 -A 50% > < 20 32/0 11 -A F32T8 - Two amp Applicationswa 100% > < 10 50/10 12 ST 60% > < 10 50/10 12 ST 30% > < 10 50/10 12 ST 100% > < 10 50/10 12 ST 2 SER-RS 60% > < 10 50/10 12 ST 30% > < 10 50/10 12 ST 100% > < 10 32/0 12 -A All models are cuus isted 50% > < 10 32/0 12 -A 100% > < 10 32/0 12 -A 50% > < 10 32/0 12 -A F32T8 - Three amp Applications 100% > < 10 50/10 15 ST 60% > < 10 50/10 15 ST 3 SER-RS 30% > < 10 50/10 15 ST 100% > < 10 50/10 15 ST 60% > < 10 50/10 15 ST 30% > < 10 50/10 15 ST See page 2-22 for Dimensions and Wiring Diagrams PAGE 2-19 FOR MORE IFORMATIO CA

12 BAASTAR IGHT EVE SWITCHIG BallaSTAR STEP DIMMIG BAASTS FOR T5 AMPS Step Dimming Programmed Rapid Start 2 amp Applications amp ine Input Power Min. F/C Starting ine Catalog Current Power Factor Factor Efficacy THD Start Wiring Qty. Method Volts umber (Amps) (Watts) (PF) (BF) Factor (BEF) % Temp Diag. Dim. F14T5 - amp Applications 100% > < 15 50/ A 50% > < 15 50/ A 100% > < 15 50/ A 50% > < 15 50/ A 100% > < 10 50/ A 50% > < 15 50/ A 100% > < 10 50/ A 50% > < 15 50/ A 100% > < 10 50/ D 50% > < 10 50/ D 100% > < 10 50/ D 50% > < 10 50/ D F21T5 - amp Applications 100% > < 10 50/ A 50% > < 15 50/ A 100% > < 15 50/ A 50% > < 15 50/ A 100% > < 10 50/ D 50% > < 10 50/ D 100% > < 10 50/ D 50% > < 10 50/ D F28T5 - amp Applications 100% > < 10 50% > < 15 50/ A 100% > < 10 50% > < 15 50/ A > < > < 20 50/ D > < > < 20 50/ D > < > < 10 50/ D > < > < 15 50/ D º Preliminary Data All models are cuus isted See page 2-22 for Dimensions and Wiring Diagrams IS = Instant Start PRS = Programmed Rapid Start RS = Rapid Start STARTIG METHOD EGED PAR-IS = Parallel Instant Start PAR-PRS = Parallel Programmed Rapid Start PAR-RS = Parallel Rapid Start SER-RS = Series Rapid Start PAGE 2-20 FOR MORE IFORMATIO CA

13 DIMESIOS AD WIRIG DIAGRAMS Overall Dimensions Mounting Dimensions Draw # W H M X -A D C ST ZZ DP DP ote: ominal dimensions provided above Contact Universal for drawings and/or tolerances WIRIG DIAGRAMS -D, DP1 -A, ST, -ZZ case must be grounded. A star washer or other paint penetrating device is required DIAGRAM 1 DIAGRAM 2 DIAGRAM 3 DIAGRAM 4 9 C11, DP2 ine S1 eutral ine S1 ine (neutral) S1 eutral eutral 5 Blk/Wht Blk/Wht ine S1 Blk/Wht Violet ine S1 (control) eutral Blk/Wht eutral Blk/Wht (neutral) PAGE 2-21 ine eutral /Wht ine eutral 10 /Wht (hot) (neutral) Gray (control -) Violet (neutral) (control +) Violet Gray (control (control -) -) ine S1 eutral ine S1 eutral ine S1 ine S1 eutral eutral ine S1 eutral ine S1 eutral ine S1 eutral ine S1 ine S1 eutral eutral Blk/Wht Blk/Wht Blk/Wht Blk/Wht Blk/Wht Blk/Wht Blk/Wht Blk/Wht Blk/Wht ine S1 Blk/Wht /Wht eutral ine S1 Blk/Wht /Wht eutral 8 ine S1 DIAGRAM 7 15 DIAGRAM 15 Blk/Wht /Wht eutral ine S1 ine Blk/Wht eutral ine S1 (hot) /Wht eutral ine (neutral) Blk/Wht eutral 7 /Wht eutral /Wht /Blk Gray /Wht (control (hot)-) /Wht /Blk /Wht DIAGRAM 8 7 ine Gray (control -) DIAGRAM 16 eutral /Wht ine eutral Violet (control +) /Wht 18 Violet +) DIAGRAM 5 DIAGRAM 6 DIAGRAM DIAGRAM 11 9 (neutral) (hot) Violet Gray (control (control +) -) ine S1 Blk/Wht eutral DIMESIOS & WIRIGine S FOR MORE IFORMATIO CA DIAGRAM 9 DIAGRAM 17 DIAGRAM 10 DIAGRAM DIAGRAM 18 DIAGRAM Violet (hot) (control -) DIAGRAM 20 eutral ine S1 eutral ine S1 eutral ine S1 eutral ine eutral ine B B Bla Blk/W Wh Bla Blk/W Wh Bla Wh Bla eutral Violet (control Wh Gray (contro Violet (contro Gray (contro (neu Violet (contr ine Gray S1 (cont B eutral ine eutral (neu Violet (contr Gray (cont S1 Blk W B Blk W W Vio Gr W Vio Gr 20

14 VariPRO 0-10V DIMMIG T8 VariPRO DIMMIG BAASTS PARAE AMP amp ine Input Power Min. F/C Starting ine Catalog Current Power Factor THD Start Wiring Qty. Method Volts umber (Amps) (Watts) (PF) Factor (BF) % Temp 1 Diag. Dim. F17T8 B232PUSV3PA B232PUSV3PA < 19 32/0 18 -A 347 B232P3SV3PA B232PUSV3PA B232PUSV3PA < 12 32/0 8 -A 347 B232P3SV3PA F25T8 B232PUSV3PA B232PUSV3PA < 15 32/0 18 -A 347 B232P3SV3PA B232PUSV3PA B232PUSV3PA < 10 32/0 8 -A 347 B232P3SV3PA F32T8 B232PUSV3PA B232PUSV3PA < 12 32/0 18 -A 347 B232P3SV3PA B232PUSV3PA B232PUSV3PA < 10 32/0 8 -A 347 B232P3SV3PA F40T8 B232PUSV3PA B232PUSV3PA < 10 32/0 18 -A 347 B232P3SV3PA B232PUSV3PA B232PUSV3PA < 10 32/0 8 -A 347 B232P3SV3PA F32T8 (30W) B232PUSV3PA B232PUSV3PA < 12 60/ A 347 B232P3SV3PA B232PUSV3PA B232PUSV3PA < 10 60/15 8 -A 347 B232P3SV3PA F28T8 B232PUSV3PA B232PUSV3PA < 14 60/ A 347 B232P3SV3PA B232PUSV3PA B232PUSV3PA < 10 60/15 8 -A 347 B232P3SV3PA F30T8 (25W) B232PUSV3PA B232PUSV3PA < 15 60/ A 347 B232P3SV3PA B232PUSV3PA B232PUSV3PA < 10 60/15 8 -A 347 B232P3SV3PA A short stabilization period may be needed for temperatures below 10C See page 2-22 for Dimensions and Wiring Diagrams PAGE 2-22 FOR MORE IFORMATIO CA

15 VariPRO DIMMIG BAASTS PARAE AMP VariPRO 0-10V DIMMIG T5 amp ine Input Power Min. F/C Starting ine Catalog Current Power Factor THD Start Wiring Qty. Method Volts umber (Amps) (Watts) (PF) Factor (BF) % Temp 1 Diag. Dim. F14T5 B228PUSV3PA B228PUSV3PA < 17 50/ A 347 B228P3SV3PA B228PUSV3PA B228PUSV3PA < 10 50/10 8 -A 347 B228P3SV3PA F21T5 B228PUSV3PA B228PUSV3PA < 13 50/ A 347 B228P3SV3PA B228PUSV3PA B228PUSV3PA < 10 50/10 8 -A 347 B228P3SV3PA F28T5 B228PUSV3PA B228PUSV3PA < 10 50/ A 347 B228P3SV3PA B228PUSV3PA B228PUSV3PA < 10 50/10 8 -A 347 B228P3SV3PA F28T5ES (25W) B228PUSV3PA B228PUSV3PA < 12 60/ A 347 B228P3SV3PA B228PUSV3PA B228PUSV3PA < 10 60/15 8 -A 347 B228P3SV3PA A short stabilization period may be needed for temperatures below 10C See page 2-22 for Dimensions and Wiring Diagrams PAGE 2-23 FOR MORE IFORMATIO CA

16 VariPRO 0-10V DIMMIG T5HO VariPRO DIMMIG BAASTS PARAE AMP amp ine Input Power Min. F/C Starting ine Catalog Current Power Factor THD Start Wiring Qty. Method Volts umber (Amps) (Watts) (PF) Factor (BF) % Temp 1 Diag. Dim. F54T5HO B254PUSV3PD B254PUSV3PD < 10 32/0 18 -D 347 B254P3SV3PD B254PUSV3PD B254PUSV3PD < 10 32/0 8 -D 347 B254P3SV3PD F54T5HOES (49W) B254PUSV3PD B254PUSV3PD < 10 60/ D 347 B254P3SV3PD B254PUSV3PD B254PUSV3PD < 10 60/15 8 -D 347 B254P3SV3PD FT55W/2G11 B254PUSV3PD B254PUSV3PD < 10 60/ D 347 B254P3SV3PD B254PUSV3PD B254PUSV3PD < 10 60/15 8 -D 347 B254P3SV3PD FC55T5HO B254PUSV3PD B254PUSV3PD < 10 60/ D 347 B254P3SV3PD B254PUSV3PD B254PUSV3PD < 10 60/15 8 -D 347 B254P3SV3PD A short stabilization period may be needed for temperatures below 10C See page 2-22 for Dimensions and Wiring Diagrams PAGE 2-24 FOR MORE IFORMATIO CA

17 evelpro DIMMIG BAASTS PARAE AMP evelpro STEP-DIMMIG HIGH BAAST FACTOR amp ine Input Power Min. F/C Starting ine Catalog Current Power Factor THD Start Wiring Qty. Method Volts umber (Amps) (Watts) (PF) Factor (BF) % Temp 1 Diag. Dim. F17T8 B232PUS50PHA B232PUS50PHA < 15 32/0 19 -A 347 B232P3S50PHA B232PUS50PHA B232PUS50PHA < 10 32/0 12 -A 347 B232P3S50PHA F25T8 B232PUS50PHA B232PUS50PHA < 10 32/0 19 -A 347 B232P3S50PHA B232PUS50PHA B232PUS50PHA < 10 32/0 12 -A 347 B232P3S50PHA F32T8 B232PUS50PHA B232PUS50PHA < 10 32/0 19 -A 347 B232P3S50PHA B232PUS50PHA B232PUS50PHA < 10 32/0 12 -A 347 B232P3S50PHA F32T8 (30W) B232PUS50PHA B232PUS50PHA < 10 60/ A 347 B232P3S50PHA B232PUS50PHA B232PUS50PHA < 10 60/ A 347 B232P3S50PHA F28T8 B232PUS50PHA B232PUS50PHA < 10 60/ A 347 B232P3S50PHA B232PUS50PHA B232PUS50PHA < 10 60/ A 347 B232P3S50PHA F30T8 (25W) B232PUS50PHA B232PUS50PHA < 10 60/ A 347 B232P3S50PHA B232PUS50PHA B232PUS50PHA < 10 60/ A 347 B232P3S50PHA A short stabilization period may be needed for temperatures below 10C See page 2-22 for Dimensions and Wiring Diagrams PAGE 2-25 FOR MORE IFORMATIO CA

18 evelpro STEP-DIMMIG ORMA BAAST FACTOR evelpro DIMMIG BAASTS IGHT-EVE SWITCHIG PARAE AMP amp ine Input Power Min. F/C Starting ine Catalog Current Power Factor THD Start Wiring Qty. Method Volts umber (Amps) (Watts) (PF) Factor (BF) % Temp 1 Diag. Dim. F17T8 B232PUS50PA B232PUS50PA < 19 32/0 19 -A 347 B232P3S50PA B232PUS50PA B232PUS50PA < 10 32/0 12 -A 347 B232P3S50PA F25T8 B232PUS50PA B232PUS50PA < 14 32/0 19 -A 347 B232P3S50PA B232PUS50PA B232PUS50PA < 10 32/0 12 -A 347 B232P3S50PA F32T8 B232PUS50PA B232PUS50PA < 11 32/0 19 -A 347 B232P3S50PA B232PUS50PA B232PUS50PA < 10 32/0 12 -A 347 B232P3S50PA F40T8 B232PUS50PA B232PUS50PA < 10 32/0 19 -A 347 B232P3S50PA B232PUS50PA B232PUS50PA < 10 32/0 12 -A 347 B232P3S50PA F32T8 (30W) B232PUS50PA B232PUS50PA < 12 60/ A 347 B232P3S50PA B232PUS50PA B232PUS50PA < 10 60/ A 347 B232P3S50PA F28T8 B232PUS50PA B232PUS50PA < 14 60/ A 347 B232P3S50PA B232PUS50PA B232PUS50PA < 10 60/ A 347 B232P3S50PA A short stabilization period may be needed for temperatures below 10C See page 2-22 for Dimensions and Wiring Diagrams See page 2-20 for Dimensions and Wiring Diagrams PAGE 2-26 FOR MORE IFORMATIO CA

19 evelpro DIMMIG BAASTS IGHT-EVE SWITCHIG PARAE AMP evelpro STEP-DIMMIG ORMA BAAST FACTOR amp ine Input Power Min. F/C Starting ine Catalog Current Power Factor THD Start Wiring Qty. Method Volts umber (Amps) (Watts) (PF) Factor (BF) % Temp 1 Diag. Dim. F30T8 (25W) B232PUS50PA B232PUS50PA < 14 60/ A 347 B232P3S50PA B232PUS50PA B232PUS50PA < 10 60/ A 347 B232P3S50PA F14T5 B232PUS50PA B232PUS50PA < 17 50/ A 347 B232P3S50PA B232PUS50PA B232PUS50PA < 10 50/ A 347 B232P3S50PA F21T5 B232PUS50PA B232PUS50PA < 12 50/ A 347 B232P3S50PA B232PUS50PA B232PUS50PA < 10 50/ A 347 B232P3S50PA F28T5 B232PUS50PA B232PUS50PA < 10 50/ A 347 B232P3S50PA B232PUS50PA B232PUS50PA < 10 50/ A 347 B232P3S50PA F28T5ES (25W) B232PUS50PA B232PUS50PA < 12 60/ A 347 B232P3S50PA B232PUS50PA B232PUS50PA < 10 60/ A 347 B232P3S50PA A short stabilization period may be neede See page 2-22 for Dimensions and Wiring Diagrams PAGE 2-27 FOR MORE IFORMATIO CA

20 It s EASY to REACH US... UIVERSA IGHTIG TECHOOGIES, IC. 51 Century Blvd., Suite 230 ashville, T GEERA IFO: (615) For Technical Engineering Services (TES), application support and warranty information, call WEBSITE: unvlt.com EMAI: webmaster@unvlt.com IT#: BC A member of the Panasonic Group

Electronic Fluorescent Ballasts

Electronic Fluorescent Ballasts Electronic Fluorescent Ballasts A Complete Range of Solutions From The Name You Trust For more than 30 years, the lighting industry has relied on our TRIAD brand for the most specified, most installed,

More information

SuperDim Analog Dimming

SuperDim Analog Dimming SuperDim Analog Dimming Technical Product Information SuperDim System Features Universal ighting s SuperDim analog ballasts offer the most cost-effective solution for energy-saving requirements. Universal

More information

SuperDim Analog Dimming Technical Product Information

SuperDim Analog Dimming Technical Product Information Universal ighting Technologies is a subsidiary of Panasonic ighting Americas, a member of the Panasonic Corporation Eco Solutions Company SuperDim Analog Dimming Technical Product Information SuperDim

More information

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps

T5 versus T8 Fluorescent Lamps. The good, the bad, & the ugly about T8 and T5 lamps T5 versus T8 Fluorescent Lamps The good, the bad, & the ugly about T8 and T5 lamps Association of Energy Engineers- Cleveland Chapter Tuesday, February 22, 2005 Presented by: Lewis S. Sternberg, LC Consultants

More information

Performance and Efficiency

Performance and Efficiency Electronic Fluorescent Quick Guide 347V Applications Fluorescent Solutions Performance and Efficiency Electronic Fluorescent Ballasts for 347V Applications Quick Guide Contents Electronic Fluorescent Ballasts

More information

Reduce Maintenance Costs *

Reduce Maintenance Costs * Reduce Maintenance Costs * Philips Advance programmed start parallel Optanium ballasts for T8 lamps helps lower maintenance costs with independent lamp operation. Philips Advance Optanium high-efficiency

More information

Ballast Selector Guide

Ballast Selector Guide Selector Guide T8 Lamp Input Volts Catalog Nbr Family Start Type Also Operates F25T8 F17T8 F40T8 F32T8ES F28T8 F32T8 & F32T8/U 1 2 3 F32T8 & F32T8/U F32T8 & F32T8/U F32T8 & F32T8/U B132IRH-A Std Electronic

More information

Ballast Selector Guide

Ballast Selector Guide 840 0 Selector Guide Lamp Type Page T8... 0 T8 and T8HO... 03 T... 04 T: HO and VHO... 05 T: Slimline... 06 T5: Long Twin... 07 T5: Standard and HO... 07 Preheat... 08 Circline... 08 Compact... 09 CFL

More information

High performance for high ceilings

High performance for high ceilings High performance for high ceilings Philips Advance Optanium programmed start parallel ballasts for T5HO and T8 lamps offers improved efficiency-saving on both energy and maintenance costs. Our new addition

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-2S26-M5-BS@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor CFQ13W/G24Q 1

More information

Section 3- Page --DCL With DEMANDflex Product Overview DemandFlex T DemandFlex T5, T5HO & TT DemandFlex T8 Wiring Diagram...

Section 3- Page --DCL With DEMANDflex Product Overview DemandFlex T DemandFlex T5, T5HO & TT DemandFlex T8 Wiring Diagram... Table of Contents Fluorescent Electromagnetic Ballasts Section 1- Page Product Overview...1-2 Application Operation Information...1-4 Typical Specifications...1-8 Lead Lengths...1-9 T8 (265 ma)...1-10

More information

ICN2S40N35I Ele Ballast (2) F40T V

ICN2S40N35I Ele Ballast (2) F40T V 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ICN2S40N35I Ele Ballast (2) F40T12 120-277V Philips Advance Catalog Number Manufacturer Description Weight per unit Product

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-2T42-M5-BS@120 Lamp Type Num. of Lamps Rated Lamp Watts M Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor CFTR32W/GX24Q 2

More information

Lighting The Way. Ballast Specification Guide

Lighting The Way. Ballast Specification Guide Lighting The Way To Energy Savings Ballast Specification Guide Ballast Specification Guide Welcome to the American Ballast family of products and services In six short years, American Ballast has built

More information

4/2/2014. Universal Overview. Presented by your Universal Agent Rep. ULT Marketing

4/2/2014. Universal Overview. Presented by your Universal Agent Rep. ULT Marketing Universal Lighting Capabilities Capabilities i Presentation Presented by your Universal Agent Rep. On behalf of the Universal sales/marketing team we appreciate the opportunity for a mutually beneficial

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT3PSP32SC@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor F17T8 3 17 50/10

More information

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts) ICF-2S42-M2-BS@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (ANSI Watts) Ballast MAX THD % Power MAX Lamp Current Crest * CFQ26W/G24Q 2 26 0/-18

More information

RZT2S54 Electr DMMG Ballast

RZT2S54 Electr DMMG Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 RZT2S54 Electr DMMG Ballast Philips Advance Catalog Number Manufacturer Description Weight per unit Product Category Features

More information

RELB2S40N35I (2)F40T12 120V Ele BLST

RELB2S40N35I (2)F40T12 120V Ele BLST 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 RELB2S40N35I (2)F40T12 120V Ele BLST Philips Advance Catalog Number Manufacturer Description Weight per unit Product Category

More information

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts) ICN-2S54-90C-T@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (ANSI Watts) Ballast MAX THD % Power MAX Lamp Current Crest F54T5/HO 1 54-20/-29 0.53

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Multiple Control s Eco s 1 06.25.10 Digital electronic dimming ballasts maximize the benefi ts of a lighting management system. Eco s offer 100% to 10% dimming; ideal for use where saving energy, increasing

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-128-D@120V Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor F14T5 1 14 50/10

More information

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts) Electrical Specifications HCN4S5490C2LSG@347 Brand Name CENTIUM T5 Ballast Type Electronic Starting Method Programmed Start Lamp Connection Series/Parallel Input Voltage 347 Input Frequency 50/60 HZ Status

More information

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts) Electrical Specifications ICN4S5490C2LSG@120 Brand Name CENTIUM T5 Ballast Type Electronic Starting Method Programmed Start Lamp Connection Series/Parallel Input Voltage 120-277 Input Frequency 50/60 HZ

More information

Everline LED Fixtures & Retrofit Kits

Everline LED Fixtures & Retrofit Kits Everline LED Fixtures & Retrofit Kits Making It Easy to Upgrade to LED Technology Upgrading from a traditional lighting system to LED lighting just makes sense (e.g. more energy savings, less spent on

More information

High Bay Lighting Solutions. Energy Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting

High Bay Lighting Solutions. Energy Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting Efficient Instant On Quiet Operation Excellent Lumen Maintenance High Quality CRI Lighting High Bay Lighting Solutions WORKING INSTANTLY, QUIETLY FOR REMARKABLE ENERGY SAVINGS Universal Lighting Technologies

More information

Lighting Tables for New Equipment 3/9/2016

Lighting Tables for New Equipment 3/9/2016 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts (Fixtures or lamps with integrated occupancy sensors may be eligible for an additional sensor rebate - see page 7) LENGTH DESCRIPTION

More information

QUICKTRONIC ICE Universal Voltage Systems

QUICKTRONIC ICE Universal Voltage Systems QUICKTRONIC ICE Universal Voltage Systems Electrodeless Fluorescent Systems Lamp / Ballast Guide lamp: ICE 40W QT1x40ICE/UNV lamp: ICE 70W QT1x100ICE/UNV lamps: ICE 100W QT1x100ICE/UNV QT1x150ICE/UNV lamp:

More information

Ballast Selector Guide

Ballast Selector Guide Selector Guide Universal Lighting Technologies is a member of the Panasonic Group. T8 s F32T8 & F32T8/U 1 2 3 4 F32T8 & F32T8/U F32T8 & F32T8/U F32T8 & F32T8/U F32T8 & F32T8/U Volts Catalog Nbr Family

More information

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts

TVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts TVE Overview Eco-0TM TVETM 0% TVE () 02.9.04 The (Eco-0) TVE is a 0% fluorescent dimming ballast for applications using a 0-0V control. TVE ballasts are also designed to work seamlessly with 0-0V lighting

More information

Electromagnetic Fluorescent Ballasts

Electromagnetic Fluorescent Ballasts Ballasts alco ighting Technologies offers Proume Ballasts for standard T1 applications, including Preheat, Rapid Start, Rapid Start igh Output and Instant Start ballasts. inimum Starting Temperature Proume

More information

LED LINEAR TUBE AFFORDABLE

LED LINEAR TUBE AFFORDABLE LED LINEAR TUBE AFFORDABLE The average commercial building contains over 300 linear fluorescent lamps. Now, imagine you replace the older fluorescent technology with newer LED technology for immediate

More information

Lighting Tables for New Equipment 2/24/2015

Lighting Tables for New Equipment 2/24/2015 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00 --- --- 2 32 207 11.00 --- --- 3 48 208 18.00 --- --- 4 57 209 18.00 --- ---

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-4PSP32-G@120V Input Voltage 120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT ALLASTS Fluorescent allasts AmbiStar SmartMate Standard T5HO PureVOLT 1 Lighting s Atlas -11 ELECTRONIC FLUORESCENT ALLASTS Fluorescent allasts Fluorescent allasts - - High-efficiency

More information

EcoSystem Multiple Control Input Ballasts

EcoSystem Multiple Control Input Ballasts Eco Five Control Digital Dimming s Eco Multiple Control s 369454l 1 09.02.16 Digital electronic dimming ballasts maximize the benefits of a lighting management system. Eco s offer 100% to 10% dimming;

More information

Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies

Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies Philips-Advance High Efficiency Ballasts & Energy-Saving Ballast Strategies Bob Trate - CPMR Philips/Advance Ballasts April 20, 2010 Fluorescent Ballast Overview There are several generations and design

More information

EcoSystemR Multiple Control Input Ballasts

EcoSystemR Multiple Control Input Ballasts EcoR Multiple Control s 369454h 1 09.15.14 Digital electronic dimming ballasts maximize the benefits of a lighting management system. EcoR s offer 100% to 10% dimming; ideal for use where saving energy,

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-4PSP32-G@120V Input Voltage 120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

Input Power (Watts) (min/max)

Input Power (Watts) (min/max) IZT-2S32-SC@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (Watts) Ballast Factor MAX THD % Power Factor Lamp Current Crest Factor F17T8 2 17 50/10

More information

VEL2S40SC35I 2 F34T12 277V Electronic Ballast

VEL2S40SC35I 2 F34T12 277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2S40SC35I 2 F34T12 277V Electronic Ballast Philips Advance Catalog VEL2S40SC35I Manufacturer Philips Advance Description

More information

Lighting Tables for New Equipment 1/1/2018

Lighting Tables for New Equipment 1/1/2018 T8 and SUPER T8 Fluorescent Lamps and Fixtures with Electronic Ballasts - REBATES are 50% of fixture/lamp cost, up to maximum amounts shown below LAMP LENGTH DESCRIPTION OF WATTS 2' F17T8 1 18 206 11.00

More information

VEL2P75S35I 2-F96T12 277V Electronic Ballast

VEL2P75S35I 2-F96T12 277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEL2P75S35I 2-F96T12 277V Electronic Ballast Philips Advance Catalog Number VEL2P75S35I Manufacturer Philips Advance Description

More information

Optanium. High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps DESIGN HIGHLIGHTS: APPLICATIONS:

Optanium. High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps DESIGN HIGHLIGHTS: APPLICATIONS: Optanium High Efficiency IntelliVolt Instant Start Ballasts for High Efficiency T8 Lamps P R O D U C T O V E R V I E W : Advance expands a new family of Smart Solutions for T8 lighting systems Optanium.

More information

Input Current (Amps) Input Power (ANSI Watts)

Input Current (Amps) Input Power (ANSI Watts) ICN-2S28-T@120 Lamp Type Num. of Lamps Rated Lamp Watts Min. Start Temp ( F/C) Input Current (Amps) Input Power (ANSI Watts) Ballast MAX THD % Power MAX Lamp Current Crest F14T5 1 14 0/-18 0.14 17 1.07

More information

Emergency lighting units EM Inverter

Emergency lighting units EM Inverter T, 0 0 V 0/0 Hz BASIC version Product description Emergency lighting supply unit for manual testing For T fluorescent lamps ow-profile casing ( x 0 mm cross-section) -year guarantee Properties or h rated

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Optanium mbistar SmartMate Standard T5HO PureVOLT 1 ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Fluorescent allasts - - Optanium High-efficiency electronic

More information

ELECTRONIC HID BALLASTS

ELECTRONIC HID BALLASTS Overview Just as electronic ballast technology enhanced fluorescent lighting systems, electronic HID ballasts bring significant performance improvements to HID lighting systems: Higher efficiency Greater

More information

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Emergency lighting units EM series. EM PRO EZ-3, V PRO version T T TC-DE TC-SE TC-TE TC-F TC- TC-DD Tc EM, 0 40 V PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent lamps

More information

Lighting Tables for Existing/Base Equipment 1/1/2014

Lighting Tables for Existing/Base Equipment 1/1/2014 T12 Fluorescent Lamps and Fixtures LENGTH Lighting Tables for Existing/Base Equipment OF CODE WATTS LENGTH OF CODE WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO

More information

Lighting Tables for Existing/Base Equipment 4/15/2011

Lighting Tables for Existing/Base Equipment 4/15/2011 T12 Fluorescent Lamps and Fixtures Lighting Tables for Existing/Base Equipment 4/15/2011 LENGTH WATTS LENGTH WATTS 2' F20T12 1 8000 28 5 F60T12 1 8029 100 2 8001 46 2 8030 135 3 8002 68 F60T12 HO 1 8031

More information

HIGH FREQUENCY ELECTRONIC BALLASTS

HIGH FREQUENCY ELECTRONIC BALLASTS HIGH FREQUENCY S Introduction High efficiency, high frequency electronic ballasts offer enhanced lighting performance and energy savings. The Electric Research Institute estimates that lighting consumes

More information

Maximum dimming versatility

Maximum dimming versatility Lighting Maximum dimming versatility The Mark 7 0 10V series of dimmable electronic ballasts offer maximum versatility by incorporating separate control leads for use with a wide array of controllers,

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Optanium mbistar SmartMate Standard T5HO PureVOLT 1 ELECTRONIC FLUORESCENT LLSTS Fluorescent allasts Fluorescent allasts - - Optanium High-efficiency electronic

More information

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number

Emergency lighting units EM series. EM BASIC lp-2, V BASIC version. Technical data. Ordering data. Article number Product description Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps ow-profile casing ( x 0 mm cross-section) Properties or h rated duration Compatible with all

More information

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast

IZT2S32SC 2 Lamp 32/T8 Dimmable Ballast IZT2S32SC 2 Lamp 32/T8 immable Ballast Philips Advance Catalog Number Manufacturer escription Weight per unit Product Category IZT2S32SC Philips Advance Electronic Ballast, High Frequency; Programmed Start;

More information

Compact SE Overview. High-Performance Dimming. Ballast

Compact SE Overview. High-Performance Dimming. Ballast Compact SE Overview CompactSE 01.10.10 For designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your solution.

More information

BALLAST SELECTOR GUIDE

BALLAST SELECTOR GUIDE BALLAST SELECTOR GUIDE Universal Lighting Technologies is a member of the Panasonic Group. T8 s F32T8 & F32T8/U 2 3 F32T8 & F32T8/U F32T8 & F32T8/U F32T8 & F32T8/U Volts Catalog Nbr Family 20 347 F32T8ES

More information

The New York University Concourse Project. New York City. Existing Electrical Conditions

The New York University Concourse Project. New York City. Existing Electrical Conditions The New York University Concourse Project New York City Technical Report TWO Existing Electrical Conditions Kevin Hsia Lighting/Electrical Option Advisor: Professor T. Dannerth November 4, 2008 Executive

More information

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming S HINE V ENTURE L IGHTING S LED LAMPS Quality retrofit LED lighting products from a leader in the lighting industry Full range dimming Longer life and up to 90% energy savings Long product life and improved

More information

ICN3P32SC35I 3-F32T8 120/277V Electronic Ballast

ICN3P32SC35I 3-F32T8 120/277V Electronic Ballast 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ICN3P32SC35I 3-F32T8 120/277V Electronic Philips Advance Manufacturer Description Weight per unit Product Category Features

More information

As easy as 1, 2, 3. Mark 10 Powerline. Benefits. Features. Application

As easy as 1, 2, 3. Mark 10 Powerline. Benefits. Features. Application Lighting As easy as 1, 2, 3 For companies looking to make their fixed-output linear T8, 4-pin CFL, and T5/HO fluorescent systems more cost effective and sustainable, ballasts provide an easy solution without

More information

FDBT S 32W120V DM Bal

FDBT S 32W120V DM Bal 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-794 ax: 936-560-4685 llenwatson@elliottelectric.com DT430S 3W0V DM al Catalog Number Manufacturer Description Weight per unit Product Category

More information

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W

Ecosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 EC3DT4MWKU1S 26/32W T4 1LMP Ba Lutron Catalog Number Manufacturer Description Weight per unit Product Category EC3DT4MWKU1S

More information

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps 3-Wire Control, 220/240 Volt T-8 Linear, rev hi-220-240-1b 1.10.02 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) HOT DIMMED HOT NEUTRAL Hi-lume Power Control Dimming Ballast Lamps DESCRIPTION Continuous,

More information

Compact SE Overview. High-Performance Dimming. Ballast

Compact SE Overview. High-Performance Dimming. Ballast allast Compact SE Overview CompactSE- 03.08.04 or designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your

More information

Table of Contents T8 Instant Start Ballasts

Table of Contents T8 Instant Start Ballasts Table of Contents T8 Instant Start Ballasts gelighting.com Ballasts Understanding T8 Fluorescent Ballasts...10-2 Understanding Fluorescent Systems...10-3 Fluorescent Ballast Application Notes...10-5 UltraMax

More information

Compact Fluorescent lighti

Compact Fluorescent lighti LED 12 20 Fluorescent 21 51 Compact Fluorescent 52 69 High Intensity Discharge 70 99 Compact Fluorescent lighti 62 Short Lamps 62 PL-C Cluster 2-Pin Lamps 63 PL-C Cluster 4-Pin Lamps 64 PL-T Triple 4-Pin

More information

Linear Line Voltage LED Engine

Linear Line Voltage LED Engine Linear Line Voltage LED Engine Product Specification Introduction The TERRALUX Linear LED Engine is a fully integrated, self-contained, plug-and-play LED solution for lighting fixture manufacturers and

More information

The smart choice for maximum flexibility

The smart choice for maximum flexibility The smart choice for maximum flexibility Philips Advance SmartMate ballasts for CFL lamps are the smart choice for maximizing flexibility while minimizing inventory Offering maximum versatility, the Philips

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS ENVIRONMENTALLY FRIENDLY, ENERGY EFFICIENT One fixture converts nearly any manufacturers incandescent, CFL or H.I.D. fixtures with a rough-in inner diameter of 7-5 /8 to 8-1 /8 diameter to high efficiency

More information

work 2013 Lighting Rebate New equipment & construction Instructions for completing the NE&C LIGHTING Rebate Worksheet General Note:

work 2013 Lighting Rebate New equipment & construction Instructions for completing the NE&C LIGHTING Rebate Worksheet General Note: Instructions for completing the NE&C LIGHTING Rebate Worksheet General Note: 1. This application is for new high efficiency lighting fixtures, systems and controls. 2. Cut sheets/specifications including

More information

Lighting Rebate 2016 Rebate Application Nobles Cooperative Electric, P.O. Box 788, Worthington, MN Ph:

Lighting Rebate 2016 Rebate Application Nobles Cooperative Electric, P.O. Box 788, Worthington, MN Ph: Lighting Rebate 2016 Rebate Application Nobles Cooperative Electric, P.O. Box 788, Worthington, MN 56187 Ph: 5073727331 Business Member Information Company name Billing address Phone Installation address

More information

Hi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming

Hi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming cosystem Hi-lume % rchitectural imming Hi-lume Overview 369-398c 06.04. Hi-lume architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements. y providing industry

More information

800 TO 9000 LUMEN 8 LED SILENT CEILING DOWNLIGHT HYPERBOLIC OPEN APERTURE L8 SERIES

800 TO 9000 LUMEN 8 LED SILENT CEILING DOWNLIGHT HYPERBOLIC OPEN APERTURE L8 SERIES ENVIRONMENTALLY FRIENDLY, ENERGY EFFICIENT Lumen packages suitable for ceiling heights ranging from 8 to over 100 Efficacies up to 109 lm/w Superior-quality white LED light output using Chip on Board technology

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

style with efficiency

style with efficiency Architectural style with efficiency and visual comfort DUALED PHILIPS DAY-BRITE / PHILIPS CFI DUALED RECESSED LED 2x2 WITH SPACEWISE TECHNOLOGY OPTION DuaLED is a highly efficient, visually comfortable,

More information

Scottsdale Vertex - SCV Petroleum Canopy LED Luminaire

Scottsdale Vertex - SCV Petroleum Canopy LED Luminaire Catalog # : Project : Prepared By : Date : Scottsdale Vertex - SCV The Scottsdale Vertex is the most feature-rich canopy fixture in the marketplace. Innovations such as combined optical distributions,

More information

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version T5 T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD T5c EM SEFTE, 220 240 V SEFTEST version Product description Emergency lighting supply unit with self-test function For linear and compact fluorescent lamps ow-profile

More information

Business Member Information Company name Billing address. City State ZIP. Installation address (if different from above) Account number.

Business Member Information Company name Billing address. City State ZIP. Installation address (if different from above) Account number. Lighting Rebate 125 Minnesota Valley Electric Dr. Jordan, MN 55352 Ph: 952.492.2313 Fax 952.492.8281 Business Member Information Company name Billing address Phone Installation address (if different from

More information

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming

Hi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming Hi-lume LED Overview Hi-lume LED 1 12.11.9 Hi-lume LED is a high-performance, constant current driver that provides energy-efficient dimming for LED lighting. With industry-leading full-range % to 1% dimming,

More information

1,2,3... As easy as. Mark 10 Powerline. For Compact Fluorescent Lamps

1,2,3... As easy as. Mark 10 Powerline. For Compact Fluorescent Lamps s easy as 1,2,3... Mark 10 Powerline immable allasts Listed 704G Philips dvance Mark 10 Powerline immable allasts make converting your existing fixtures easy. For companies looking to make their fixed-output

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS ELECTRONC FLUORESCENT S Ballast Life Philips Advance fluorescent electronic and magnetic ballasts are designed and manufactured to engineering standards correlating to an average life expectancy of 50,000

More information

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube

3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube 3-Wire Control, 120, 277 Volt, T4 Quad Tube and T4 Triple Tube rev hi-compact-1a 3.7.01 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) T4 - One Lamp 3.00 w (76mm) x 1.00 h (25mm) x4.90 l (124mm) T4 - Two

More information

LIGHTPLANE 11 RECESSED

LIGHTPLANE 11 RECESSED LIGHTPLANE 11 RECESSED SPECIFICATION GUIDE Architectural Lighting Works reserves the right to make changes to fixture design finish and engineering at any time. www alwusa.com Page 1 of 4 Specification

More information

INSTANT START BALLASTS

INSTANT START BALLASTS ULTRAMAX INSTANT START BALLASTS GE Consumer & Industrial TRANSFORMING THE POWER OF LIGHT Take Energy Savings to the MAX with Take Energy Savings to the MAX with High Efficiency Electronic Ballasts NEW

More information

Idaho Profile System - Surface

Idaho Profile System - Surface Direct Asymmetric L3ID-SUR-SYS Article # Mounting Distribution Diffuser Length Angle Voltage Linear Spot x Qty Electrical Finishes Accessories Lighting Type Couplers Control Product Mounting Distribution

More information

Steve Sindoni Commercial Engineer OSRAM Sylvania

Steve Sindoni Commercial Engineer OSRAM Sylvania Steve Sindoni Commercial Engineer OSRAM Sylvania Lighting Energy Efficient Product & Industry Update A Brief Overview of Energy Efficient Lighting Systems -T8 & T5 systems -Energy management ballasts

More information

J TO 4000 LUMEN 8 LED CYLINDER HYPERBOLIC/PARABOLIC/WALLWASH OPEN APERTURE LC8 SERIES DIMENSIONS 1-1/4

J TO 4000 LUMEN 8 LED CYLINDER HYPERBOLIC/PARABOLIC/WALLWASH OPEN APERTURE LC8 SERIES DIMENSIONS 1-1/4 ENVIRONMENTALLY FRIENDLY, ENERGY EFFICIENT Lumen packages suitable for ceiling heights ranging from 8 to over 50 Efficacies up to 80 lm/w Superior-quality white LED light output using Chip on Board technology

More information

Idaho Profile System - Trimless

Idaho Profile System - Trimless 3 4/16 82mm DIRECT 3 9/16 90mm 3 6/16 85mm L3ID-TRI-SYS DR OP Article # Distribution Diffuser Length Voltage Linear Electrical Mounting Brackets Lighting Control Product Distribution Diffuser Length Voltage

More information

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA Illuminator Series LV Single Phase ILLUMINATOR SERIES LV The Illuminator Series LV is a 175VA-750VA fast transfer Emergency Lighting

More information

The right components for your application

The right components for your application Product Catalog The right components for your application 08-09 Atlas full line guide to conventional lighting Table of contents - TLED Drivers - Electronic Fluorescent allasts 3- Fluorescent Controllable

More information

ELECTRONIC FLUORESCENT BALLASTS

ELECTRONIC FLUORESCENT BALLASTS Ballast Life Philips Advance fluorescent electronic and magnetic ballasts are designed and manufactured to engineering standards correlating to an average life expectancy of 50,000 hours of operation at

More information

Recessed. EvoKit LED Retrofit Kits Gen 3

Recessed. EvoKit LED Retrofit Kits Gen 3 Project: Recessed Location: Cat.No: Type: Lamps: Qty: EvoKit LED Retrofit Kits Gen 3 2'x2' Notes: Philips EvoKit LED Retrofit Kit is an energy efficient LED alternative to traditional linear fluorescent

More information

LUFOHB IP65. Premium Round LED High Bay, 14,000 32,000 Lumens ( W) WARRANTY & LISTINGS FEATURES MOUNTING OPTIONS DIMENSIONS

LUFOHB IP65. Premium Round LED High Bay, 14,000 32,000 Lumens ( W) WARRANTY & LISTINGS FEATURES MOUNTING OPTIONS DIMENSIONS Catalog Number Project Type LUFOHB 14,000 32,000 ( 240W) STANDARD The LUFOHB is a premium round LED high bay luminaire It is designed to illuminate a wide variety of settings including commercial, industrial

More information

Idaho Profile System - Suspension

Idaho Profile System - Suspension INDIRECT DIRECT ASY 3 1/8 80mm 2 15/16 75mm L3ID-SUS-SYS Article # Distribution Diffuser Length Angle Voltage Linear Spot x Qty Electrical Power Suspension Finishes Lighting Couplers Feed Cable Controls

More information

Scottsdale Vertex - SCV Petroleum Canopy LED Luminaire

Scottsdale Vertex - SCV Petroleum Canopy LED Luminaire Catalog # : Project : Prepared By : Date : Scottsdale Vertex - SCV The Scottsdale Vertex is the most feature-rich canopy fixture in the marketplace. Innovations such as combined optical distributions,

More information

Controls. CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES

Controls.   CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES SPECIFICATION SUBMITTAL s The contractor s choice in rugged, linear slide dimmers. www.lutron.com/nova CONTROLS AND ACCESSORIES Slide-to-Off s Preset s Select light level with slider; slide down to off

More information

Installation Instructions

Installation Instructions SPECIFICATIONS v2 Fixture Mount Power Pack Model: Fixture Sensor Power Pack V2 120/277/347VAC, 60Hz @347VAC 3.4A () 2A () Power...120/277/347VAC, 60Hz Relay Type... Form C with Zero Crossing on N.O. only

More information