1 ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA Illuminator Series LV Single Phase
2 ILLUMINATOR SERIES LV The Illuminator Series LV is a 175VA-750VA fast transfer Emergency Lighting Inverter utilizing Myers Power Products advanced technology. The Illuminator LV is designed to support the needs of smaller facilities and those now utilizing LED lighting technology. This system meets all requirements of UL924 including self-testing and is listed by UL (Underwriters Laboratories). In addition, the optional meter panel feature of this system will allow the end user to meet the advanced testing & logging requirements as defi ned by NFPA101. The ability to support any lighting source including, but not limited to LED, Fluorescent, and HID enhances the ability of the end user to design the space for the fi t, form, and function they desire. The Illuminator LV (as well as all of the Myers Power Products family of Emergency Lighting Inverters) is designed so that any light fi xture that is appropriate for your facility can be chosen and used for both normal and emergency lighting. This means that the architectural features and design of a space do not have to be compromised by the use of additional types of fi xtures added solely to meet the emergency lighting requirements. The Illuminator Series LV design is highly effi cient, minimizing the overall operating costs of your emergency lighting system. The design utilizes fast transfer technology which is an offl ine 2mS transfer system; able to support all lamp sources, the offl ine system is extremely reliable and effi cient making it exceptionally economical to own and operate. With a substantially smaller footprint, this unit is available in 4 distinct capacities (175W, 350W, 550W, and 750W) and can be either wall or fl oor mounted. In addition, the 175 watt system is available in an optional ceiling grid mounted version where it is designed to be plenum rated. See page 5 for dimensions or visit our website at STANDARD VERSUS ADVANCED SYSTEM CODE COMPLIANCE Photos 2 Advanced Systems: The advanced (Model Type 2 and 3) LV Series inverter is compliant with UL924 self-testing standards as well as NFPA101 self-testing standards. This system comes complete with a programmable meter panel (system mounted, remote mounted or handheld). This system performs a 5 minute runtime test 11 times a year and, a 90 minute runtime test 1 time a year. The dates and times of these tests are fully programmable by the end user. This system captures the last 25 tests in its internal test log. In addition to the advanced testing functions, this system allows complete access to a wide variety of data regarding the status of the system through the meter panel. Standard Systems: Myers standard (Model Type 1) LV Series inverter is compliant with UL924 self-testing standards. It is provided with a self-test feature that runs a test every 28 days and one extended yearly runtime test. This test is not programmable and is controlled by an internal clock embedded in the system electronics. After a successful completion of either of these tests the systems will indicate as such by illuminating the Ready LED indicator light. If a failure of either of these tests occurs, the Ready LED indicator will fl ash. There is no record or log of these tests. A complete list of functions is available in the Metering Manual on Myers website at Standard Model Type 1 Advanced Model Type 2 and 3 Testing Metering Data Logging Alarms UL924 Self-Testing/ not available not available Visual Self-Diagnostic UL924 Self-Testing/ Self-Diagnostic NFPA101 Self-Testing/ Self-Diagnostic System mounted, remote mounted, or hand-held Alarm log, event log, test log Audible and Visual 1
3 ADVANCED SYSTEM DESIGN FEATURES NFPA 101 self-testing, self-diagnostic, and logging OLED display system mounted meter panel provides access to systems logs and programming (Remote and handheld options available). See page 4 of the ordering guide Control panel has an easy to use 4-button keypad which is used to access all information Metering function and system status allows access to a multitude of data regarding the electrical characteristics of the system including input voltage, input current, input frequency, output voltage, output current, output power, battery voltage, battery current, battery temperature, battery power, internal ambient temperature, heat sink temperature, UPS events, UPS time and system days online System setup allows the user to set parameters and customize settings that can indicate out of tolerance conditions Monthly and yearly tests can be programmed by the user to meet the date and time requirements of the facility In addition to basic alarms, advanced alarms include: input frequency low, input frequency high, input voltage low, input voltage high, output voltage low, output voltage high, battery voltage low, battery voltage high, battery temp low, battery temp high, ambient temp low, ambient temp high, and on inverter timer STANDARD SYSTEM DESIGN FEATURES PWM/MOSFET pure sine wave inverter technology Microprocessor controlled 90 minute runtime High effi ciency; no fans required UL 924 listed UL 924 self-testing and self-diagnostic Field selectable voltage; 120 volt input/output or 277 volt input/output Compatible with all light sources including LED, HID, Fluorescent, Incandescent, Quartz and Electronic Low Voltage Lighting High Crest Factor inrush capabilities Red Wall Mounted cabinet (other mounting options and colors available; see ordering guide page 4) Maintenance free VRLA batteries System Status indicators and momentary test switch Input fuse and battery fuse protection Summary Alarm Form C dry contacts Available outputs: normally on and 1 normally off or switched output Normally off has an available 15 minute time delay Output circuit breakers are available for 350, 550 and 750W models Alarms include monthly test fault, yearly test fault, charger fault, load reduction fault, output voltage low, output voltage high, overload fault, low voltage disconnect, heatsink over temp and input fuse failure 2
4 ADVANCED SYSTEM OPTIONS VARIABLE TIME DELAY Allows for programmable delay of inverter retransfer to continue supplying emergency power to the normally off output for up to 15 minutes after the return of power OUTPUT CIRCUIT BREAKERS Maximum output breakers available: 750 watt system 6 total, 350/550 watt system 3 total, 175 watt system 0 available. Normally on, normally off, and switched options available BACNET Allows for communications of data from the inverter using BACnet protocol. Myers user configurable system is a full MS/ TP master slave device USB MASS STORAGE Provides additional storage capabilities for up to 3000 alarms and 60 test logs. USB option allows for system logs to be copied to USB flash drive for import to data management program (software included). This option expands the capabilities of internal data and alarm logging METERING PANELS Available in three configurations: System mounted, Remote mounted, and Handheld FAST CHARGE A battery charger upgrade which decreases the time to recharge a fully discharged battery bank to a full charge. The recharge time is decreased from the standard 24-hour period to a 12-hour period MOUNTING Wall mount (standard); optional recessed wall mount and plenum rated grid mount (175 watt only) and floor mount (350/550/750) PROGRAMMABLE INPUT / OUTPUT OPTIONS STATUS MONITORING CONTACTS (FACTORY PRESET TO LISTED ALARMS (Option C )) AC Present, Inverter On/Off, Test Failure, System Overload, Near Low Batery, Blown Fuse Indicator AVAILABLE STATUS MONITORING CONTACTS (6 MAXIMUM IN SYSTEM WITHOUT SWITCHED OUTPUT) On Battery, Charger Failure, Overcurrent, AC Present, Monthly/Yearly test failure, Load reduction alarm, System overload, Input voltage high/low, Output current, High ambient temperature, High battery temperature, Inverter ON/OFF, Near low battery, Blown fuse indicator SWITCHED OUTPUT CIRCUIT BREAKERS Up to 3 separate switched 10 amp output circuit breakers. The number of switched outputs will reduce available contact relays (see chart on page 4) ZONE MONITORING (Option Z ) Monitors AC power presence in a specific zone (area, distribution panel, etc.). Upon loss of power in the zone(s), the inverter will turn on, activating all normally off (emergency only) circuits. All normally on loads will remain on. When primary power returns in the zone(s), inverter will turn off after its preset delay and normally off loads will turn off. Consult factory for quantity limits per application. 3
5 ORDERING GUIDE Example Model Number LV-2-R-2-B2003-F-HH LV 2 R 2 B F HH SYSTEM TYPE 1 LV - Illuminator Series LV VA/W MODEL TYPE ENCLOSURE COLOR 8 R - Red (Standard) W - White G - Grey B - Black 1 - Standard (UL924) Internal Meter Panel and Advanced Testing & Logging (UL924 & NFPA101) 3 - Advanced Testing & Logging (UL924 & NFPA101) 5, 7 Wall Mounted Unit is Standard VA=W Normally off not available when using switched output Requires Model Type 3 Requires HH or RMP option to retrieve data 175W OCB s not available, 350/550W 3 OCB s max, 750W 6 OCB s max No meter panel included Grid mounted system standard color is white All other models, standard color is red Optional colors available Internal meter panel is not available with grid mount cabinet Maximum of 3 switched outputs, each with 10 amp circuit breaker on Type 2 & 3 systems, only 1 switched output is available on Type1 system Multiple switched outputs limit available alarm contacts (see chart below) Requires Model Type 2 or 3 Options Not available with options "C","Z" or systems with more than 1 switched output Not available with options "H","Z" or systems with more than 1 switched output 9 OUTPUT OUTPUT BREAKERS Example: B X - None B - Normally On N - Normally Off S - Switched AMP RATING 5, 10, 15, 20 QUANTITY , 10 3 ACCESSORIES HH - Handheld Meter Panel (one HH can be used for multiple units) RMP - Remote Meter Panel (1 per system) (requires model type 3) 6 4 OPTIONS B - Floor Mount (not available on 175 watt) C - Status Monitoring Contacts (see chart below) 12, 14 D - NEMA 2R Drip Top F - Fast Charge Option 12 8, 9 G - Grid Mount (175 watt only) H - BACnet 12, 13 R - Infrared Remote Test S - Battery Strapping U - USB Mass storage 12 W - Recessed wall mount (175 watt only) Z - Zone Monitoring 12 AVAILABLE OUTPUT CIRCUIT BREAKER AND OPTIONS CONFIGURATIONS Output Circuit Breaker Available Configurations for 350/550/750 VA systems Quantity of available Form C contacts Zone Monitor inputs available Status Monitoring Option "C" BXX Available BXX Not Available BXX Available BXX Not Available BXX Available BXX Not Available S Not Available S Available S1001-BXX Not Available S1001-BXX Available S1001-BXX Not Available S1001-BXX Available S Not Available S1002-BXX Not Available S Not Available XX = Breaker amperage (5,10,15 or 20A Available) B = Normally On breaker S= Switched Output circuit breaker(s) (10A Breaker only available). 750 VA system, 3 additional Normally On Output Circuit Breakers are available If Normally Off Breakers are required contact factory for assistance 4
6 SYSTEM SPECIFICATIONS ILLUMINATOR LV ILLUMINATOR LV-2 & LV Height ILLUMINATOR LV-1G ILLUMINATOR LV-4 ELECTRONICS MODULE Base Model BATTERIES (90 Full Load) Power Rating (VA/W) Efficiency (@ full load) Audible Noise (db Heat Loss (BTU)/HR Number of Batteries Voltage (VDC) Current (amps) Cabinet Dimensions Width in/cm Depth in/cm Height in/cm LV % / / / / / /24.97 LV1G % / / / / / /24.97 LV % / / / / / /45.4 LV % / / / / / /59.02 LV % / / / / / /81.72 Weight lbs/kg 90 Minute Batteries lbs/kg Total System Weight lbs/kg 5
7 SYSTEM SPECIFICATIONS Input Output Voltage Input Frequency Synchronizing Slew Rate Protection Harmonic Distortion Voltage Static Voltage Dynamic Voltage Harmonic Distortion Overload Output Frequency Load Power Factor Inverter Overload Output Types Protection Crest Factor 120 or 277Vac 1-phase 2-wire +10% -15% 60Hz, +/-3% 1 Hz per second nominal Fuse < 10% (For Resistive Load) 120 or 277Vac 1-phase 2-wire Load current change +/- 2%, battery discharge +/- 12.5% +/- 10% for load step change, recovery within 5 cycles < 3% THD for linear load Circuit Breaker protected (Optional) 60Hz +/-.05 Hz during emergency mode.5 lag to.5 lead 250% for 16 Cycles, 110% continuously Normally On, Normally Off or Switched Optional Distribution Circuit Breaker(s) (350, 550 and 750W) 3.5 Battery Type Charger Protection Disconnect Valve-regulated sealed lead-calcium Microcontroller, 3-stage charger (recharge per UL-924 Specifications) Automatic low battery disconnect; automatic restart upon utility return Fuse Environmental General Altitude Operating Temperature Storage Temperature Relative Humidity Design Generator Input Indicator Lights & Switch Optional Control Panel Optional Metering Standard Alarms Optional Alarms Alarm Contacts Warranty Optional Warranties < 10,000 feel (above sea level) without derating Inverter: 0 to 40 C (32 to 104 F) Battery: 20 to 30 C (68 to 86 F) per UL to 70 C (-40 to 158 F) (electronics only) < 95% (non-condensing) Line interactive PWM inverter type utilizing MOSFET technology with 2mS transfer time Compatible with generators. (25KVA or larger) Charging. Ready, Inverter and Test switch OLED display with key pad controls/functions & scrolling system status Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Input Current, Inverter Wattage Ambient/Battery/Heatsink Temperature, Input Frequency, UPS Time & Events, Days of Operation Monthly Test Fault, Yearly Test fault, Charger Fault, Load Reduction Fault, Output Voltage Low, Output Voltage High, Overload Fault, Low Voltage Disconnect, Heatsink Overtemp and Input Fuse Failure Input Frequency Low, Input Frequency High, Input Voltage Low, Input Voltage High, Output Voltage Low, Output Voltage High, Battery Voltage Low, Battery Voltage High, Battery Temp Low, Battery Temp High, Ambient Temp Low, Ambient Temp High and On Iinverter Timer Summary Fault Form C 3 year standard warranty includes all parts; 10 years prorated warranty on batteries Extended warranties, Preventative Maintenance and/or Customized Service Plans. Physical Cabinet Cooling Cable Entry Access Wall Mount; Recess or T-Grid available only on 175W system Convection Cooled Top or Side Front 6
8 Illuminator Series E/IE Single Phase 1.5KVA to 16.7KVA Illuminator Series CIII Three Phase 4.8KVA to 50KVA Illuminator Series EM Single Phase 1KVA to 2.8KVA Illuminator Series CR/DR Single and Three Phase Outdoor System 3KVA to 8KVA 44 South Commerce Way Bethlehem, PA Tel: (800) Fax: (610)
Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System
Illuminator Series CM GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System This description contains all the necessary functional and technical
More informationIlluminator Series CR NEMA 3R
Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the
More informationGLX. Series. 1kW to 16kW Central System
GLX Series 1kW to 16kW Central System GLX Series Sine Wave RATINGS TABLE Size Input Current @120V Output Current @120V Input Current @277 Output Current @277 Output Watts Battery (DC) Voltage 1kW 16 8
More informationSTL. Series. Emergency Lighting Inverter 3kW to 160kW Central System
STL Series Emergency Lighting Inverter 3kW to 160kW Central System STL Series Sine Wave APPLICATIONS: The STL Series Inverter will operate incandescent, fluorescent, HID and LED lamps. *Depending on the
More informationTechnical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality
GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino
More informationLumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:
APPLICATIONS LLMPS Series inverter systems are designed to provide sinusoidal AC emergency power to incandescent, flourescent, or LED fixtures of between 20 and 55 watts. Surface, recessed or ceiling T-Grid
More informationEMEX. Central Battery Systems Emergency Lighting
EMEX Central Battery Systems Emergency Lighting 2 Table of Content General Presentation 3 & 4 Single Phase Systems 5 & 6 Three Phase Systems 7 & 8 Optional Features 9 User Interface and Display 10 What
More informationDefender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications
Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting
More informationCobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications
Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System
More informationsystems Systems Emergency Lighting Inverter 120 or 277V 60 Hz Power
systems Systems Emergency Lighting Inverter 120 or 277V 60 Hz Power RATINGS TABLE Size Batteries Volts S = Series SP = Series Parallel Total Weight 525 2 24 V S 153 700 4 48 V S 193 1000 4 48 V S 444 1250
More informationEON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems
EON Model EL3 Three Phase Centralized Emergency Lighting Inverter General Specification 10KW 33KW Systems 1.0 GENERAL This specification defines the electrical and mechanical characteristics and requirements
More informationPOWER kva
TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power
More informationEON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems
EON Model EL3 Three Phase Centralized Emergency Lighting Inverter General Specification 40KW 55KW Systems 1.0 GENERAL This specification defines the electrical and mechanical characteristics and requirements
More informationLiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible
LiteMinder Fast Transfer System 1.0 to 18.75KVA LED Compatible Series Inverter Pure Sine Wave Modular Inverter Technology Modular AC System Evenlite s LiteMinder Central Inverter System provides an innovative
More informationPOWER kva
+44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw
More informationFortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications
Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state
More informationPower Lynx 3 Uninterruptible Power System (UPS) Technical Specifications
Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible
More informationIlluminator System Series CIII
Illuminator System Series CIII 6.7 kw (hr Run) 50 kw Users Manual South Commerce Way, Bethlehem, PA 807-800-56-5088 (60) 868-500 Fax: (60) 868-8686 Service: (60) 868-500 www.myerspowerproducts.com C A
More informationAurora Single Phase Emergency Lighting Inverters
Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available
More informationTECHNICAL DATA SHEET KVA UPS Systemss
Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800
More informationAPC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply
APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous
More informationTECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)
TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5
More informationPOWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)
TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)
More informationSola 3000 Guide Specifications
Sola 3000 Guide Specifications CSI 16610 - Static Uninterruptible Power Supply Systems - Sola 3000 Guide Specifications for a 700 to 2200 VA Single - Phase Uninterruptible Power Supply System 1.0 GENERAL
More informationEFFEKTA Power Supplies
EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power
More informationUniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model
UniStar III Series 1, 2, & 3kVA Tower Model On-line, Single-phase UPS System The UniStar III is a sophisticated yet affordable single phase, double conversion UPS system. It offers on-line technology and
More informationFortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications
Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting
More informationTECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)
TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5
More informationSmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9
SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 MODEL NUMBER: AL-84111 Specifications OUTPUT Output Volt Amp Capacity (VA) 2200 Output kva Capacity
More informationPOWERTRONIX QUASAR 5-40 KVA
POWERTRONIX QUASAR 5-40 KVA DT 0251 E00 TECHNICAL DATA Rev. Description Date Checked Released Date Type of doc. Page n Pag. Tot. ISSUED 07.03.2000 E.Borsa 07.03.2000 Approved A.Gorlani Pag.1/6 Cod. DT251
More informationEaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC
Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0
More informationOff-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER
Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS REMOTE LOCATIONS COMMERCIAL VEHICLES RV/MARINE BACKUP POWER Do you need reliable AC power in a vehicle, remote location or for emergency backup?
More informationPOWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting
POWER+ PREMIUM CBS CENTRALIZED Battery System BS-EN-50171 Emergency electrical installations Electric power systems Emergency lighting Escape lighting POWER+ PREMIUM CBS 10KVA-40KVA The systems running
More informationTechnical data sheets
GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company
More informationgimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy
GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,
More informationTECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III
TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III 1. SCOPE A. The Central Lighting Inverter shall be a solid-state three phase system designed to provide
More informationSURE-LITES LIFEWAY II SERIES
SURE-LITES LIFEWAY II SERIES MICRO MODULAR INVERTER SERIES 500W,000W Users Manual C A U T I O N READ ENTIRE MANUAL AND REVIEW ALL DOCUMENTATION BEFORE ATTEMPTING SYSTEM INSTALLATION FOR SERVICE OR INSTALLATION
More informationSmart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass
Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass APC Smart-UPS VT, 24 kw / 30 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9
More informationINVERTER/CHARGERS Off-Grid Power Solutions
EVOLUTION SERIES INVERTER/CHARGERS Off-Grid Power Solutions REMOTE LOCATIONS RV/MARINE COMMERCIAL VEHICLES BACKUP POWER www.samlexamerica.com Do you need reliable AC power in a vehicle, remote location
More informationCEPS Series UL924 Emergency Lighting Inverters
UL924 Emergency Lighting Inverters CEPS lighting inverters are a powerful, reliable, and cost effective way to meet emergency lighting and life safety requirements for a wide range of applications. Turn
More information3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:
TECHNICAL GUIDE SPECIFICATIONS Power-Lite Single Phase, (200 to 490 Watts) UL924 Central Lighting Inverter 1. SCOPE The Emergency Lighting Power System shall be a solid-state single phase unit designed
More informationDPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE
DPP/DPP Digital Process INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE PROVIDING CONTINUITY OF ELECTRICAL POWER DPP/DPP DIGITAL PROCESS POWER Industrial Pulse Width Modulated
More informationATevo SERIES BATTERY CHARGER
PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative
More informationSURE-LITES LIFEWAY II Series C & IPS
SURE-LITES LIFEWAY II Series C & IPS.5 kw 6.7 kw Users Manual C A U T I O N READ ENTIRE MANUAL AND REVIEW ALL DOCUMENTATION BEFORE ATTEMPTING SYSTEM INSTALLATION FOR SERVICE OR INSTALLATION INFORMATION:
More informationAT EVO SERIES BATTERY CHARGER
STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation
More informationTLE Series UPS 400/500 kw With eboost Technology
TLE Series UPS 400/500 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical power
More informationSola/Hevi-Duty S3K Series Mini-Tower UPS
Sola/Hevi-Duty S3K Series Mini-Tower UPS GUIDE SPECIFICATIONS 700VA to 1600VA 120V models Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical
More informationEVO AT SERIES BATTERY CHARGER
EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T PATENT PENDING hindlepowerinc.com 610-330-9000 Evo AT Series battery charger designed with YOU in mind. Evo AT Series battery charger
More informationSmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS
SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS MODEL NUMBER: S3M60KX Highlights Best-in-class footprint and power density minimize space requirements for up to 60kVA
More informationModel ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase
Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible
More informationLiebert PowerSure PSI UPS
Liebert UPS GUIDE SPECIFICATIONS 1000VA to 3000VA Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical and mechanical characteristics and
More informationINTRODUCING THE NEW MINI INVERTERS BY READY-LITE
INTRODUCING THE NEW MINI INVERTERS BY READY-LITE RELIABILITY THROUGH TECHNOLOGY FOR ECONOMICAL, RELIABLE POWER IN AN EMERGENCY, DEPEND ON MINI INVERTERS LED technology in emergency lighting systems has
More informationSmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option
SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SVT20KX Highlights On-line double-conversion topology, VFI operation
More informationTechnical Data Sheets
GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01
More informationTECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT
TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT 1.0 PURPOSE: 1. To charge the battery bank through Solar PV source and AC supply. 2. To invert and produce utility quality sine wave. 3. Inverters
More informationTLE Series UPS 160/200/225/250 kw with eboost Technology
TLE Series UPS 160/200/225/250 kw with eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical
More informationSmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired
SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired MODEL NUMBER: SU20K3/3 Description Tripp Lite's SU20K3/3 20kVA SmartOnline
More informationSeries. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM
Series 6 and 10 kva Tower On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set user
More informationRELIABILITY THROUGH TECHNOLOGY
INTRODUCING THE NEW MINI INVERTERS BY LUMACELL RELIABILITY THROUGH TECHNOLOGY MAXIMIZE EFFICIENCY AND RELIABILITY WITH MINI INVERTER EMERGENCY POWER As LED technology increases the efficacy of emergency
More informationEVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER
EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER Evo Series battery charger designed with YOU in mind. Evo Series battery charger is a next generation SCR-based utility battery charger. This evolutionary
More informationSeries. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM
Series 6 and 10 kva Rack Mount On-line, Single-phase Parallel Redundant UPS System n Power range and runtime scalability n Full-time Digital Signal Processor Control n LCD/LED mimic panel n Easy-to-set
More informationThree Phase UPS Systems Range: 10 to 500kVA
Three Phase UPS Systems Range: 10 to 500kVA Three Phase UPS Systems Hitachi Hi-Rel Power Electronics Pvt. Ltd. is in the business of Industrial UPS Systems since 1987 and has rich experience in supplying
More informationLiebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL
1.1 SUMMARY Liebert GXT3 8000 & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL This specification shall define the electrical and mechanical characteristics and requirements
More informationAT SERIES EVO BATTERY CHARGER
AT SERIES EVO BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T hindlepowerinc.com 610-330-9000 AT Series evo. A battery charger designed with YOU in mind. AT Series evo is HindlePower s next generation
More informationTECHNICAL SPECIFICATIONS for. Telecommunication Battery Backup Systems (TBS)
TECHNICAL SPECIFICATIONS for Single Phase, Outdoor, 400 Watt to 1600 Watt Uninterruptible Power System and Power Conditioner NEMA 3R & NEMA 4 Cabinet Telecommunication Battery Backup Systems (TBS) TBS6507A
More informationPOWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division
POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com
More informationPOWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division
POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES GAMATRONIC, A SolarEdge Division 47505 Seabridge Drive, Fremont, CA, 94538 USA Tel: 1-800-277-5496 SalesNA.Gama@solaredge.com www.gamatronicna.com
More informationSpecial Specification 6058 Battery Back-Up System for Signal Cabinets
Special Specification Battery Back-Up System for Signal Cabinets 1. DESCRIPTION 2. DEFINITIONS Install a Battery Back-Up System (BBU System) for traffic signals that will provide reliable emergency power
More informationPower+ CLASSIC. 20/30 kva, 3x208 Vac
Power+ CLASSIC 20/30 kva, 3x208 Vac with internal batteries Power+ CLASSIC 20/30 kva, 3x208 Vac Power+ is a family of modular, parallel, redundant UPS systems from Gamatronic one of the leading companies
More informationTLE Series UPS 750/1000 kw With eboost Technology
TLE Series UPS 750/1000 kw With eboost Technology The new TLE Series Uninterruptible Power Supply (UPS) is a three-phase high power product with best-in-class multi-mode efficiency for global critical
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 150 200 250 300 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationEATON 9315 UPS 200 TO 300 KVA Specifications
EATON 9315 UPS 200 TO 300 KVA Specifications Input Voltage Range See table below Frequency Range (60Hz) 57-64 Hz (50Hz) 47-53 Hz Surge Protection Meets ANSI C62.41, Category A & B EN 50091-2 and EN50082-2
More informationUninterruptible Power Supplies
S5KC Modular Series On-ine Uninterruptible Power Systems (UPS) The S5KC Modular UPS is scalable from 5 to 20 kva, offering many flexible options by adding a few standard modules. Designed to be fully configured,
More informationD Series: UPS UPTO - 300KVA - Three / Three Phase
D Series: UPS UPTO - 300KVA - Three / Three Phase All in one D Series UPS High Power UPS Systems, Now in India Properties : Standard Properties 1GBT rectifier inverter technology Input power factor correction
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
REC EPO STATUS BAT OUTPUT MUTE Critical Power Technical Data Sheet Uninterruptible Power Supply TLESM_UL_015-090_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationLiebert GXT-MT 1-3kVA UPS. Power Protection for Business Critical Continuity
Liebert GXT-MT 1-3kVA UPS Power Protection for Business Critical Continuity Trouble is Coming Down The Line And You Must Be Prepared Every operation in your business depends upon the instant, around-the
More informationTechnical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER
Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...
More informationUninterruptible Power System
USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible
More informationDELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw
DELPHYS GP Green Power 2.0 range 160 to 1000 kva/kw OBJECTIVES The aim of these specifications is to provide: the information required to choose the right uninterruptible power supply for a specific application.
More informationOFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility
OFF-GRID PV IVERTERS EssenSolar & Expert series Solution on Unstable or Remote Area without 1kW-5kW FSP Off-Gird Inverters: EssenSolar & Expert series An ideal Off-Grid inverter for households, FSP Off-Grid
More informationPowerValue 11/31 T kva
Technical Datasheet PowerValue 11/31 T 10-20 kva Classification IEC/EN 62040-3 VFI-SS-111 Working mode on-line double conversion Power rating 10-20 kva Paralleling up to 4 units (up to 80 kva) Output power
More informationSmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option
SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT20K Highlights On-line double-conversion topology, VFI operation
More informationLiebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS
1.1 SUMMARY Liebert GXT4 8000 & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL This specification shall define the electrical and mechanical characteristics and requirements
More informationTechnical Specification SENTINEL PRO
Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES
More informationTechnical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work
Technical Data Sheet Uninterruptible Power Supply TLES_040-120_S1_UPS_GE_Floor_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41
More informationGUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY
CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 TOSHIBA 4400 15/20/25/30/50/80kVA Internal Transformers GUIDE SPECIFICATION
More informationStandard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA
V Series 120/120VAC Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven
More informationMaster DIALOG INDUSTRY RANGE
Local Area Networks (LAN) Servers Data centers Internet centers (ISP/ASP/POP) Industrial PLCs Emergency devices (lights/alarms) Electro-medical devices Telecommunication devices Industrial applications
More informationTOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY
CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 TOSHIBA 4400 15/20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE
More informationLiebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL
1.1 SUMMARY Liebert GXT3 10000VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL This specification shall define the electrical and mechanical characteristics and requirements for a continuousduty,
More informationLiebert GXT & 6000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL
1.1 SUMMARY Liebert GXT4 5000 & 6000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL This specification shall define the electrical and mechanical characteristics and requirements
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33U Series / 10 20 30 40 50 60 kva 208 VAC UL Series 1 Date of issue: 11/05/2008 LPS33U_030-040_S1 GE_01
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH
More informationCONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9
USER MANUAL 1 CONTENTS 1. INTRODUCTION... 1 2. SAFTY INSTRUCTION... 3 3. CABLE CONNECTION... 4 4. SYSTEM DESCRIPTION... 5 5. OPERATION... 9 6. TROUBLE SHOOTING GUIDE... 25 7. OPERATION MODES..... 27 8.
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series
More informationOn-line, Single Phase, Double Conversion UPS
V Series Standard Universal Tower/Rack Mount 1, 2, 3 kva On-line, Single Phase, Double Conversion UPS The UniStar V features a field-proven Digital Signal Processor (DSP) achieving high reliability, while
More information1.1 GENERAL CHARACTERISTICS
1.1 GENERAL CHARACTERISTICS General characteristics - Frame Values Unit Model: Conceptpower DPA 500, UL Series Power, rated: Apparent 500 kva Active 500 kw Power, range 100-3000 kw UPS type: online, transformerless,
More informationUninterruptible Power Systems
Sola 4K Industrial On-Line Uninterruptible Power Systems (UPS) The true on-line (double conversion) protection offered by the S4K Industrial UPS series eliminates a wider range of potential power problems
More informationSeries 120/120VAC Universal Tower/Rack Mount
V Series 120/120VAC Universal Tower/Rack Mount Standard 1000VA, 1500VA, 2000VA & 3000VA LB Extended Models 900VA, 1250VA, 1700VA & 2500VA On-line, Single Phase, Double Conversion UPS The UniStar V features
More information