List of A/T Issued During Year

Size: px
Start display at page:

Download "List of A/T Issued During Year"

Transcription

1 List of A/T Issued During Year 0-0 Sr. Name of Items Name of the Firm A/T. & Date KV VCB 50A Capacitor Bank Panel Stelmec E 5/5,.0. KV VCB 50 A Feeder Panels Stelmec E 5/5,.0. KV 00A VCB Bus Coupler Panels Stelmec E 5/5,.0. KV VCB 00A Incomer panels Stelmec E 5/5,.0. KV VCB 50 A Incomer panels Jyoti E 5/55,.0. KV VCB 50 A 7 Panel Board Jyoti E 5/55,.0. KV VCB 50 A Feeder Panels Jyoti E 5/55,.0. KV VCB 50A Capacitor Bank Panel CGL E 5/5,.0. KV 00A VCB Bus Coupler Panels CGL E 5/5,.0. KV VCB 00A Incomer panels CGL E 5/5,.0. KV VCB 50A Capacitor Bank Panel Megawin E 5/57,.0. KV VCB 50 A Incomer panels Megawin E 5/57,.0. KV VCB 50 A 7 Panel Board Megawin E 5/57,.0. KV VCB 50 A Feeder Panels Megawin E 5/57,.0. 5 KV CT /A, C (w/o Structure) Mehru E /0, KV CT /A, C (w/o Structure) Mehru E /0, KV CT /A, C (w/o Structure) Victrans E /07, KV CT /A, C (w/o Structure) Victrans E /07, KV PT (w/o Structure) Kapco E /0, KV CT /A, C (w/o Structure) JSL E /09, KV PT (w/o Structure) JSL E /09, KV CT /A, C (w/o Structure) JSL E /09, KV C&R Panel for Transformer with Diff. Protn. ABB E 5/, 0V DC - Bus KV C&R Panel for Transformer with Diff. Protn. ABB E 5/, 0V DC - Bus KV C&R Panel for line, 0 V DC, Bus. ABB E 5/, KV C&R Panel for line, 0 V DC, Bus. ABB E 5/, KV C&R Panel for Transformer with Diff. Protn. ABB E 5/, 0V DC - Bus KV C&R Panel for Transformer with Diff. Protn. ABB E 5/, 0V DC - Bus KV C& R Panel for line, 0 KV DC - Bus ABB E 5/, KV C&R Panels for Line - 0 V DC, Bus Popular E 5/, KV C& R Panel for Line - 0 V DC Bus. Popular E 5/, KV C&R Panel for transformer with Diff. Protn. Popular E 5/, 0V DC Bus KV C&R Panel for transformer with Diff. Protn. Popular E 5/, 0V DC Bus KV C&R Panel for transformer without Diff. Protn. Popular E 5/, 0V DC Bus KV C&R Panel for Line with reactor - 0 V DC, Areva E 5/, Bus.05. KV OD VCB (Without Structures) Areva 7/,.0. KV LA with Clampp connecotr suitable for single Lamco E 9/, Zebra (with Structures).0. 0 KV LA with Clamp connector suitable for single Lamco E 9/, moose (With Structures).0. KV LA w/o Structures with clamp connector Lamco E 9/, suitable for panther.0. KV LA w/o Structures with clamp connector Lamco E 9/, suitable for single moose..0. KV VCB ( Of 00A Inc., + of 50A Stelmec E 9/, Feeder Pnls.) Panels board.0. KV VCB 50 A 7 Panel Board Stelmec E 9/,.0. 5 KV VCB 50 A 7 Panel Board Jyoti E 9/7,.0. KV 00A CB Isolator with EB, Structure, GR Power E-55/9, 0.0. KV 00 A CB Isolator without EB with Structure, GR Power insulators KV DB Isolator with EB, structure, insulators & GR Power Clamp Connectors suitable for twin Zebra Order 0-.xls : ORDER ISSUED -05- of

2 Name of Items Name of the Firm KV DB Isolator without EB, structure, insulators & GR Power Clamp Connectors suitable for twin Zebra A/T. & Date 0 0 KV 00 A CB Isolator with EB, with structure, GR Power insulators 0 KV 00 A CB Isolator without EB, with structure, GR Power insulators KV 00 A DB Isolator with EB, Structure & Sterling E-55/9, insulators KV 00 A DB Tandem Isolator w/o EB with Sterling structure & insulators KV 00A CB Isolator with EB, Insulator & Danke E-55/95, Structure KV 00 A DB Isolator w/o EB with Structure & Danke insulators 0 KV 00 A DB Tandem Isolator w/o EB with Danke structure & insulators KV CT /--A Kapco /09, 50 9 KV CT /--A Kapco 9 KV O/D PT Kapco 0 KV CT /--A JSL /0, 9 0 KV CT /--A JSL 7 0 KV O/D PT JSL 0 00 KV CT /A C w/o structure. Areva E-7/99, KV CT /A C w/o structure. CGL E-7/9, KV CT /A 5C w/o structure. CGL 9 0 KV CT /A, 5C w/o structure CGL 7 0 KV CT /A, 5C w/o Structure CGL 0 KV PT w/o structure CGL 0 KV CT /A, C w/o structure Hivoltrans E-7/97, KV CT /A, C w/o structure Mehru E-7/99, 0.0. KV CT /A, 5C w/o Structure Mehru 9 KV CT 00-00/A, 5C, w/o Structure Mehru 5 KV PT w/o Structure Mehru KV CT /A, 5C w/o structure Mehru 9 KV CT /A, C w/o structure Mehru 5 KV CT /A, 5C w/o Structure Universal E-7/00, Magnoflux KV CT 00-00/A, 5C, w/o Structure Universal Magnoflux 5 KV NCT w/o Structure Universal Magnoflux 5 KV CT /A, 5C w/o structure Universal Magnoflux 0 5 KV CT /A, C w/o structure Universal Magnoflux 5 KV Feeder C&R Panels (0V DC, Bus) Maktel E-7/, KV Transformer C&R Panel with Differential Maktel Protection, (0V DC, Bus) 7 7 KV Transformer C&R Panel with Differential Hertz E-7/0, Protection, (0V DC, Bus) KV Feeder C&R Panels (0V DC, Bus) Popular E-7/, KV Transformer C&R Panel with Differential Popular Protection, (0V DC, Bus) 9 KV 50 A, Motor operated HDB Isolators w/o E/B, with Structure. Danke E-95/75, KV 50 A, Motor operated HDB Isolators w/o E/B, Danke without Structure. 9 KV 0A, Motor operated HDB Isolators w/o E/B, Danke without Structure... 9 KV 0A, Motor operated HDB Isolators with E/B, with Structure as per spe. but with clamp connectors suitable for Single Moose. 9 KV, 0A, MOTOR OPERATED ISOLATOR WITH E/B, W/O STRUCTURE. 9 KV, 0A, MOTOR OPERATED ISOLATOR, W/O EB, WITH STRUCTURE. 0 KV 0A, Motor Operated HDB Isolator w/o E/B, with str. but with clamp connectors suitable for single moose. Danke Danke Danke Sterling E-95/7, KV 0 A Motro operated Isolator with E/B w/o Str. Sterling. 0 KV, 0A, MOTOR OPERATED ISOLATOR, W/O Sterling. EB, WITH STRUCTURE. 95 KV 50A, Motor Operated HDB Isolator w/o E/B Universal E-95/77, w/o Structure Isolators 0.0. KV 0 A Motor operated HDB Isolator w/o E/B Universal w/o Structure. Isolators KV 0 A Motor operated HDB Isolator with E/B Universal w/o Structure. Isolators 75 KV VCB 50A Capacitor Bank Panel Stelmec E 5- RO/7, KV VCB 50 A Feeder Panels Stelmec KV 00A VCB Bus Coupler Panels Stelmec KV VCB 00A Incomer panels Stelmec KV VCB 50 A Incomer panels Jyoti E 5-RO/ 7, Order 0-.xls : ORDER ISSUED -05- of

3 Name of Items Name of A/T. & KV VCB 50 A Panel Board Jyoti KV VCB 50 A Feeder Panels Jyoti KV VCB ( Of 00A Inc., + of 50A Stelmec E 9-RO/ Feeder Pnls.) Panels board 7, 0.0. KV VCB 50 A 7 Panel Board Stelmec 5 KV VCB 50 A 7 Panel Board Jyoti E 9-RO/ 7, KV CT /A, 5C w/o structure CGL E-7-Addl KV CT /A, 5C w/o Structure CGL 5 0 KV PT w/o structure CGL 7 KV VCB 50A Feeder Panels Stelmec E-/5, KV 00 A VCB Incomer Panels Stelmec 7 KV 50 A VCB Incomer Panels Jyoti E-/, KV 50 A VCB (+) 7 Panel Boards Jyoti 7 9 KV VCB 50 A Feeder Panels Megawin E-/, KV VCB 50 A Incomer panels Megawin 9 KV 50 A VCB (+ 5) Panel Boards Megawin 9 KV 50 A VCB (+) 7 Panel Boards Megawin KV CB Isolator with structure, with E/B GR Power E-5/5, KV CB Isolator with structure, w/o E/B GR Power 00 KV Pentograph isolator with Structure, with E/B Siemens E-5/5, KV Pentograph isolator with Structure, w/o E/B Siemens 00 KV Single Ph. E/S for 00 KV Bus with PI & Siemens structure. 9 KV CT /A, C, with structure. JSL E-/5, KV CT /A, C, with structure. JSL 5 KV CT /A, C, w/o structure. JSL 5 KV CT /A, C, w/o structure. JSL 9 KV CT /A, C, with structure & Clamp JSL connector for single Moose. KV PT with Structure and Clamp connector JSL suitable for single moose. KV CT /A, C, with structure. JSL KV CT /A, C, w/o structure. JSL 577 KV 0.S Metering CT /A, with structure Victrans E-/ 5,.09. KV CT /A, C, with structure. Victrans 7 KV CT /A, C, with structure & Clamp Victrans connector for single Moose. KV CT /A, C, with structure. Victrans 55 KV CT /A, C, w/o structure. Victrans KV CT /A, C, w/o structure. Victrans 9 KV PT with Structure and Clamp connector Victrans suitable for single moose. KV CT /A, C, with structure. Victrans KV CT /A, C, with structure & Clamp Mehru E-/5, connector for single Moose KV CT /A, C, w/o structure. Mehru 5 KV CT /A, C, w/o structure. Universal E-/5, Magnoflux KV CT /A, C, with structure & Clamp Universal connector for single Moose. Magnoflux 5 KV CT /A, C, w/o structure. Universal Magnoflux 5 KV CT /A, C, with structure & Clamp Hivoltrans E-/ 57, connector for single Moose KV 0. Cl. Metering PT with structure. Hivoltrans 7 Pilot Installation of Digital Instrument Trasnformers at Areva DIT/955, 0 KV Jambuva S/S:.09. Ph., Wire DAS Meter /A Secondary L&T E-_R/ 7,.. 7 Ph., Wire DAS Meter /5A Secondary L&T 5 9 KV & 0KV Isolators. GR Power E-55/00, KV LA with Structure. Lamco E-/0, KV LA w/o Structure. Lamco E-/0,.. 5 KV LA with structure CGL E-/0, 5 KV LA w/o Structure CGL KV LA with structure CGL 5 KV LA with structure CGL KV PT without Structure CGL E-7/, KV PT's. JSL E-/0, KV PT with Structure Victrans E-09/9, KV PT w/o Structure Victrans E-09/9, KV CT /A, C (metering + PS) Universal E-09/5, w/o Str Magnoflux KV CT /A,C with Str. Universal E-09/9, Magnoflux KV CT /A c (metering + PS) Mehru E-09/, with Str Order 0-.xls : ORDER ISSUED -05- of

4 Name of Items Name of A/T. & 5 KV CT /A c (metering + PS) Mehru E-09/, w/o Str KV CT /A C w/o Str. Mehru E-09/, KV CT /A,C with Str. Mehru E-09/, KV CT /A C W/o Str. Mehru E-09/, KV CT /A C (metering + PS Mehru E-09/, Class Cores) W/o Str KV CT /A C w/o Str. Areva E-09/7, KV PT with Str. CGL E-09/, KV X'mer C&R Panel w/o diff. Protection. (0V DC Popular E-7/55, - Bus) KV X'mer C&R Panel w/o diff. Protection. (0V DC Maktel E-7/, - Bus).0. 7 Global Positioning System (GPS) based time Masibus E-/5, synchronization Equi..0. KV Feeder CRP (0V DC, Bus) PSPL E-/59, KV Trf. CRP (0V DC, Bus) PSPL KV Trf. CRP without Differential (0V DC, Bus) PSPL KV Trf. CRP without Differential (0V DC, Bus) PSPL KV Trf. CRP without Differential (0V DC, Bus) PSPL 0 KV BB CRP 0 V DC, Bus, Bays (0 KV Chandrapura S/S) Areva E-5/5, KV BB CRP 0 V DC, Bus, Bays (0 KV Areva Vijapur S/S) 0 KV BB CRP 0 V DC, Bus, 9 Bays (0 KV Areva Chhatral S/S) 0 KV BB CRP 0 V DC, Bus, 9 Bays (0 KV Areva Jetpur S/S) 0 KV BB CRP 0 V DC, Bus, 0 Bays (0 KV Areva Asoj S/S) 0 KV BB CRP 0 V DC, Bus, Bays (0 KV Areva Soja S/S) 00 KV BB CRP 0 V DC, Bus, 7 Bays (00 KV Areva Asoj S/S) 00 KV BB CRP 0 V DC, Bus, 7 Bays (00 KV Areva Soja S/S) KV 50 A, VCB Panel Board under buyback Jyoti E-5/,.0. KV 50 A, VCB Feeder Panel under Buyback Jyoti KV 50 A, VCB Incomer Panel under Buyback Jyoti 5 KV 50 A, VCB Panel Board under buyback Megawin E-5/,.0. 5 KV 50 A, VCB Feeder Panel under Buyback Megawin 5 KV 50 A, VCB Incomer Panel under Buyback Megawin KV 50 A, VCB Panel Board under buyback Stelmec E-5/,.0. KV 50 A, VCB Capacitor Bank Panel under Stelmec Buyback (RVT) KV 50 A, VCB Feeder Panel under Buyback Stelmec KV 50 A, VCB Incomer Panel under Buyback Stelmec KV 50 A, VCB Bus Coupler Panel along with bus trunking Panel under Buyback Stelmec 7 KV SF Breakers CGL E/77, MVA /.55KV Power Transformers T&R E-/0, MVA /.55KV Power Transformers IMP E-/09, KV BPI, Clamp connector for single moose w/o Aditya Birla E9/e 577, Structure KV BPI clamp connector for panther w/o Structure Aditya Birla 0 KV BPI clamp connector for twin moose w/o Structure 7 KV BPI clamp connector for twin Zebra w/o Structure Aditya Birla WS Ind. E9/e 5777, KV, 90KN Susp. type SRI BHEL E-0/79, KV, 0KN Ten. type SRI BHEL 7 KV, 0KN Ten. type SRI Lumino Ind E-0/770, KV, 90KN Susp. type SRI G.K.Xianghe E-0/77, KV, 90KN Ten. type SRI G.K.Xianghe 7 KV, 0KN Ten. type SRI G.K.Xianghe 7 KV, 90KN Susp. type SRI G.K.Xianghe 0 7 KV, 0KN Ten. type SRI G.K.Xianghe KV, 90KN Susp. type SRI G.K.Xianghe 9 Order 0-.xls : ORDER ISSUED -05- of

5 Name of Items Name of A/T. & 7 0 KV, 0KN Ten. type SRI G.K.Xianghe 75 KV, 90KN Susp. type SRI Deccan E-0/77, KV, 90KN Ten. type SRI Deccan KV, 0KN Ten. type SRI Deccan 0 75 KV, 90KN Susp. type SRI Deccan KV, 0KN Ten. type SRI Deccan 95 7 AL 59 conductor having weight equivalent to JSK Ind. e-07/77, KM. ACSR Zebra AL 59 conductor having weight equivalent to Apar Ind E-07/775, Km. ACSR Zebra KV SF Breaker & buy back ABB E-/7, KV SF Breaker & buy back Areva E-/,.0. 0 KV SF Breaker & buy back CGL E-/9, KV SF Breaker & buy back CGL 5 /.55KV, 5MVA Power ntransformer with Shilchar E-0/9, SCADA compatibility.0. 7 KV SF Breakers CGL E-/ Addnl/ 0,.0. KV SF Breakers CGL E-/,.0.0 0KV SF Breaker Siemens E /, KN Antifog Allied Ceramics E /, KN Antifog India Potteries E 7, 500 0KN Antifog India Potteries KN Antifog Aditya Birla E /,.0. 7 KV, 90KN Susp. type SRI BHEL E 0/5, 700 KV, 90KN Ten. type SRI BHEL 00 0 KV, 90KN Susp. type SRI BHEL KV, 0KN Ten. type SRI BHEL KV, 90KN Susp. type SRI G.K.Xianghe E 0/5, 00 KV, 90KN Ten. type SRI G.K.Xianghe 0 KV, 0KN Ten. type SRI G.K.Xianghe KV, 90KN Ten. type SRI Lumino Ind E 0/5, 00 0 KV, 90KN Susp. type SRI Lumino Ind KV, 0KN Ten. type SRI Lumino Ind 50 9 KV, 90KN Susp. type SRI Deccan E 0/55, 970 KV, 90KN Ten. type SRI Deccan 50 KV, 0KN Ten. type SRI Deccan 50 KV, 90KN Susp. type SRI Deccan 00 KV, 0KN Ten. type SRI Deccan 00 0 KV, 90KN Susp. type SRI Deccan ACSR Dog Conductor Gupta Power E 0/559, KM ACSR Dog Conductor Prem Cables E 0/50, KM. 700 ACSR Panther Conductor Prem Cables KM..5 ACSR Zebra Conductor Prem Cables KM. 9 ACSR Panther Conductor Bharat Al'sing E 0/5, KM. 0 ACSR Zebra Conductor Bharat Al'sing KM ACSR Panther Conductor North Eastern E 0/5, KM ACSR Panther Conductor Venkateshwara E 0/5, KM ACSR Zebra Conductor JSK Ind. E 0/5, KM. 7 ACSR Moose Conductor JSK Ind. KM. 9 KV SF Breakers CGL E/75, set KV MVAr (Phase) Line Reactor with oil CGL E Erection, testing & commi. of all the acc. of 00 KV CGL E MVAr (Phase) line Reactor 00 KV 50 MVAr (Phase) Line Reactor CGL Erection, testing & commissioning CGL 00 5MVA,00/0/ KV Auto X'mer with oil, with Air EMCO E cell Erection, testing & comm. of all the acc. of EMCO E 5MVA,00/ 0/ KV Auto X'mer 0 / kv, 50 MVA Auto Transformer with air cell T&R E Erection, testing & comm. of all the acc. of / T&R E kv, 50 MVA Auto X'mer 0 Supply of 00MVA, 0/ KV Power X'mer, with oil, T&R E- Addl air cell Erection, testing & comm. of all the equip. of 00MVA, 0/ KV Power X'mer T&R E- Addl Supply of 00 MVA, 0/ KV Auto transformer with oil T&R E- Addl Erection, testing & comm. of all the equip. of 00 T&R E- Addl MVA, 0/ KV Auto X'mer 0 ACSR Panther Conductor Prem Conductors E-9/, Km ACSR Panther Conductor North Eastern E-9/5, KM ACSR Dog Conductor JSK Ind. E-9/, KM ACSR Panther Conductor Venkateshwara E-9/7, KM Order 0-.xls : ORDER ISSUED of

6 Name of Items Name of A/T. & 07 ACSR Dog Conductor Aravali E-9/, KM. Infrapower KV SF Breaker & buy back Areva E-/75, KV SF Breaker & buy back CGL E-/759, KN Antifog Aditya Birla E-9/79, 07 0KN Antifog Aditya Birla KN Antifog WS Ind. E-9/79, 590 0KN Antifog WS Ind KN Antifog BHEL E-9/79, /KV 5 MVA Power transformer & buy back Shilchar E-05/05, N erection testing & commissioning of 5MVA Shilchar transformer 00KV MVAr Bus Reactor T&R E-/0, /KV 5 MVA Power transformer Technical E-5/0, Associates MVA, 0/ KV Power Transformer T&R E-/, Erection, testing & commissioning T&R 00MVA, 0/ KV Auto Transformer T&R Erection, testing & commissioning T&R 7 00MVA, 0/ KV Power Transformer Bharat Bijlee E-, Erection, testing & commissioning Bharat Bijlee 00MVA, 0/ KV Power Transformer EMCO E-/5, Erection, testing & commissioning EMCO 9 /KV 0 MVA Power transformer & buy back IMP E-05/, erection testing & commissioning of 0MVA IMP transformer /KV 5 MVA Power transformer & buy back IMP 9 erection testing & commissioning of 5MVA IMP transformer 9 0 /KV 0 MVA Power transformer & buy back T&R E-05/, erection testing & commissioning of 0MVA T&R transformer 5 /KV 5 MVA Power transformer & buy back T&R 5 erection testing & commissioning of 5MVA T&R transformer 5 00MVA, 0/ KV Auto Transformer IMP E-/, Erection, testing & commissioning IMP KV SF Breakers CGL E-- RO/5,.09. 0KV SF Breakers Siemens E- RO/50, KV SF Breakers ABB E-/5, KV SF Breakers ABB 5 KV SF Breakers Areva E-/5, 00KV SF Breakers w/o PIR Areva KV SF Breakers CGL E /97, KV SF Breakers CGL E /9, \.09. ACSR Dog Conductor JSK Ind. E0/9, KM. 5 ACSR Zebra Conductor JSK Ind. KM. ACSR Moose Conductor JSK Ind. KM. 7 9 ACSR Dog Conductor NECCON E- KM. 0/95, KV-Sus-long rod Insulator-90KN Modern E-9/97, KV-Ten-long rod Insulator-90KN Modern 770 KV-Ten-long rod Insulator-0KN Modern 00 KV-Sus-long rod Insulator-90KN Modern KV-Ten-long rod Insulator-0KN Modern 5 /KV 0MVA Power Transformer Atlanta E-0/505, /KV 5MVA Power Transformer Atlanta 5 /KV 0MVA Power Transformer Atlanta /KV 5MVA Power Transformer IMP E- /Addnl/5 0,.09. /KV 5MVA Power Transformer T&R E- /Addnl/50,.09. /KV 0MVA Power Transformer IMP E-0/Addnl/ 509, /KV 0MVA Power Transformer Atlanta E-5/5,.09. /KV 0MVA Power Transformer Atlanta 90KN Antifog Bikaner Cermics E-/5500, 500 Order 0-.xls : ORDER ISSUED -05- of

7 Name of Items Name of A/T. & 0KN Antifog Bikaner Cermics ACSR Panther Conductor NECCON E 0/RO/ KM. 55,.0. 5 ACSR Dog Conductor JSK Ind. E 0/RO/ KM. 55, ACSR Dog Conductor Gupta Power E 0//RO/ KM. 555, ACSR Panther Conductor Venkateshwara E 0/RO/ KM. 55, ACSR Panther Conductor Bharat Al'sing E 0//RO/ KM. 557, MVA, 0/ KV Power Transformer Atlanta E-/575, 7.0. KV BPI Modern e-7/59, KV BPI Modern 00KV BPI Modern 0 0KV BPI WS Ind. e-7/0, KV BPI Aditya Birla e-7/, 0KV BPI Aditya Birla 00KV 5MVAr Bus Reactor CGL E-050/77, Erection, testing & commissioning CGL 7 00KV 0MVAr Bus Reactor ABB E-050/7, Erection, testing & commissioning ABB. KV XLPE Cable Polycab. E-/7, Kms Oracle Database Server Accel Fronline 70/57 Nos - 50 Vaccume Circuit breaker Tester Technology E-/, Nos Products Control Cable Ravi Cable E-9/95, kms - c x sq mm Ravi Cable 9.00 c x sq mm Ravi Cable.00 c x.5 sq mm Ravi Cable.00 5 Control Cable Laxmi Power E-9/95, c x.5 sq mm Laxmi Power c x.5 sq mm Laxmi Power.00 c x.5 sq mm Laxmi Power c x.5 sq mm Laxmi Power.00 7c x.5 sq mm Laxmi Power 0.00 c x 0 sq mm Laxmi Power.00 5 Thermovision Camera Automation E-/7, LT Panel 00 A Hertz e-0/ LT Panel for 00 A (SCADA) Maktel E-0/7, V DCDB with 5 Feeder (SCADA) Maktel.00 5 LT Panel 00 A Bharat Electricals E-0/ GI Stay Wire Sona Wires E-5, MT Turn Ratio Meter Madhav E-/0,.0. Nos 59 Dist. Transformer /.KV, KVA Powerkraft Inc. E-9/ Circuit Breaker Analyser with Channel DCRM M Tekpro Engg E-/55, 0.0. Nos 7 LT Panel for 00 KV (SCADA) Popular Eurja 595/ 75, V, DCDB with 0 Feeder Taj e urja 595/ 7, cx0 sq mm XLPE Cable Havells India E-00/59, Kms.07. KV cx5 sq mm XLPE Cable Hindusthan E-00/5, kms Vidyut XLPE Cable Diamond Power E-00/5, Kms Cx0 sq mm Diamond Power.00 cx5 sq mm Diamond Power.00 Control Cable Laxmi Power E-9/77, Kms Cx.5 sq mm Laxmi Power.00 9c x.5 sq mm Laxmi Power.00 7c x.5 sq mm Laxmi Power c x.5 sq mm Laxmi Power Control Cable Ravi Cable E-9/779, Kms c x.5 sq mm Ravi Cable 5.00 c x.5 sq mm Ravi Cable 9.00 cx sq mm Ravi Cable.00 c x sq mm Ravi Cable 5.00 Online Partial Discharge Utility Power E-/59, Nos mesaurement Kit Battery Impedance Kit Systematic E-/0, No GI Earth Wire Himachal wire E-79/00, Kms 9 GI Stay Wire Himachal wire MT 5 7 LT Panel 00 A Hertz eurja0505/99 7,.0. 7 LT Panel 00 A Taj eurja05/7 7,.0. 7 Dist. Transformer /.5 KV, 500 KVA Danke E-9 Nos 9 7 KVA,.55KV/00-0 V, Ph. Distribution Mihir E-/7, Nos Transformers Eelectrotrans KV XLPE Cable cx 0 sq mm Torrent cables Ltd E-R/ Kms 7. Order 0-.xls : ORDER ISSUED of

8 Name of Items Name of A/T. & 7 KV XLPE Cable cx 0 sq mm Universal Cables. E-R/, Kms 5.9 Ltd Control Cable - c x.5 sq mm Ravi Cable E-9 Kms 5 Addl/55, - c x.5 sq mm Ravi Cable 9 - cx sq mm Ravi Cable - c x sq mm Ravi Cable 7 Control Cable - c x.5 sq mm Ravi Cable E-9R/ 59, Kms c x.5 sq mm Ravi Cable 0 79 Control Cable - 7c x.5 sq mm Laxmi Power E-9 Kms 5 Addl/550, - Cx.5 sq mm Laxmi Power 7-9c x.5 sq mm Laxmi Power - 7c x.5 sq mm Laxmi Power 0 Control Cable - 7c x.5 sq mm Laxmi Power E-9R/ 55, Kms Cx.5 sq mm Laxmi Power - 9c x.5 sq mm Laxmi Power - 7c x.5 sq mm Laxmi Power Control Cable - c x.5 sq mm Ravi Cable E-9R/ 90, Kms 7 - c x sq mm Ravi Cable Control Cable - c x.5 sq mm Laxmi Power E-9R/ 959, Kms - 7c x.5 sq mm Laxmi Power - c x.5 sq mm Laxmi Power 7-9c x.5 sq mm Laxmi Power - 7c x.5 sq mm Laxmi Power Cable Height Meter Balaji 77/55 Nos 0.0. Arc Retardant Suit Madhav 7/55 Nos GI Earth Wire UIC Udyog Ltd E-5/5 Kms.0. Oracle Server System Hardware HCL E-/ Nos Server for Oracle HCL Storage Array HCL KVM switch with LCD, Keyboard & Mouse HCL Tap Drive HCL Rack HCL Intel CPU Based server for web based applications HCL Installation & Commissioning of Oracle Server HCL Hardware Equipments 7 Radio Link with Associated Equipments Midaas E-/7 dtd.. Puncture Insulator Detector Madhav 9/9, 5.. RO 9 Contact Type Voltage Detector Motwane E-5/07 No 50 Manufacturing dtd Contact Type Voltage Detector Madhav E-5/ 9 No 50 Hand Held Dew Point Meter Madhav No 90 DC IR Tester (0KV) Motwane E-/ No 0 Manufacturing dtd Voice Logger (SLDC) Intellicon Pvt Ltd Voice No Logger/7, DC IR Tester (KV) Balaji E-/ No Digital Earth Tester Balaji No 7 9 Supply of Digi C/CON ( port, RS, RJ-5 U, 9 Honeywell SLDC?50 dtd No Installation and comm. of relevant H/W Honeywell No 9 Control Cable - c x.5 sq mm Laxmi Power E-5/, Kms - c x.5 sq mm Laxmi Power 0 95 Control Cable - 7c x.5 sq mm Suyog Electricals E-5/7, Kms 9 - c x.5 sq mm Suyog Electricals c x.5 sq mm Suyog Electricals - 7c x.5 sq mm Suyog Electricals 0 - c x sq mm Suyog Electricals - c x sq mm Suyog Electricals 9 75OHM,UNBALANCEDARMOUREDCO-AXIAL Alpha E-R/ 9, Kms. CABLE Communication KV XLPE Cable cx 00 sq mm Diamond Power E-/ 07, Kms KV XLPE Cable cx 0 sq mm Diamond Power Kms 0 9 KV XLPE Cable cx 0 sq mm Torrent cables E-R/, Kms.5 Ltd KV XLPE Cable cx 0 sq mm Universal Cables. E-R/ 90, Kms 0.7 Ltd KV XLPE Cable cx 00 sq mm M/s Hindustan E-VD/, Kms KV XLPE Cable cx 0 sq mm Vidyut.0. Kms 0 75OHM,UNBALANCEDARMOUREDCO-AXIAL M/s Alpha E-R/ 5, Kms. CABLE Communication Ltd Control Cable - c x.5 sq mm Laxmi Power Cable Pvt. Ltd E-5R/ 0,.0. Kms 5 0 Control Cable - 7c x.5 sq mm Suyog Electricals E-5R/, Kms.5 - c x.5 sq mm Limited KV PVC Copper Cx50 sq mm Earthing Cable Uniflex Cables Ltd. E-/,.0. Kms Order 0-.xls : ORDER ISSUED -05- of

9 Name of Items Name of the Firm A/T. & Date 05 0 V, 00AH Lead acid Battery with FRP stand HBL E-/59, and acce. First charging and Comm V, 50AH Lead acid Battery sets with FRP stand Autobat E-/, and acce. under B/B with Ere. & Comm.'.0. 0V, 50AH Lead acid Battery sets with FRP stand Autobat and acce. under B/B with Ere. & Comm. 07 0V, 0AMP, -Ph BATTERY CHARGER Servilink E-/0, No V, 50 AH Battery sets with FRP Stand and Acce. Servilink with Ere. & Comm. 5 0V, 50 AH Battery set with FRP Stand and Servilink Accessories with Ere. & Comm. 0V, 50AMP, -PH Battery Charter. Servilink No 7 0V, 50A, -PH Battery Charter. Servilink No 0 0V, 50AMP, -PH Battery Charter for 50AH Hertz E-/, No Battery V, 0AMP, -ph Battery Charger for 00A/H Hertz No battery 0V, 50A, -PH, Battery Charer, for 50 AH Battery Hertz No. 09 Copper Earth Bonds Tinned Braided Eeteel E-0/09, No EW Suspension Clamp for 7/0 SWG 7/.5 mm Eeteel No 55 TENSION CLAMP FOR Eeteel No 57 7/0 SWG 7/.5 MM Midspan Compression Joint for Pnather 0 SQMM Eeteel No 9 Repair Sleeves for Dog 5 SQMM Eeteel No 0 Single Suspension H/W normal for Panther Eeteel No 09 0 Armour Rods Preformed for Dog Aumni E-0/05, No.05. Armour Rods Preformed for Panther Aumni No 7 Double Suspension H/W normal for Zebra Aumni No 5 Midspan Compression Joint for DOG 5 SQMM Aumni No Midspan Compression Joint for Panther 0 SQMM Aumni No 7 Repair Sleeves for Dog 5 SQMM Aumni No Single Suspension H/W normal for Panther Aumni No 9 Single Tension H/W normal for Dog Aumni No Single Tension H/W normal for Zebra Aumni No Fire Wage connector for Zebra to Moose Conductor Ahura E-0/07, No.05. Double Suspension H/W normal for Panther Krsna E-0/09, No Single Tension H/W normal for Panther Krsna No 9 Stock Bridge vibration damper for Panther Cond. Krsna No 70 Cross by Clip for 7/0 E/W Gayatri E-0/0, No Double Tension H/W for Twin Moose Cond. Gayatri No IPS ALLU. TUBULAR BUSBAR PIPE- INCH Gayatri No 5 Spacer for Twin Moose Gayatri No 00 Armour Roads Preformed for Panther Rumika E-0/0, set Double suspension H/W normal for Dog Rumika set 0 Double Suspension H/W Normal for Moose. Rumika set Double Suspenson H/W normal for Twin Zebra Rumika set 9 Double suspension H/W normal for Zebra Rumika set Double Tension H/W for Twin Moose Cond. Rumika set 0 Double Tension H/W normal for Moose. Rumika set Double Tension H/W normal for Twin Zebra Rumika set 5 Single Suspension H/W for Single Moose. Rumika set 9 Single Suspension H/W normal for Zebra. Rumika set Single Tension H/W for Single Moose. Rumika set 5 Single Tension H/W normal for Dog. Rumika set 900 Single Tension H/W normal for Zebra Cond. Rumika set 5 Double Tension H/W normal for Dog, Milap E-0/090, No Double Tension H/W normal for Panther. Milap No 55 Midspan Compression Joint for Dog 5 SQMM Milap No 57 Single Suspension H/W normal for Dog. Milap No 5 Stock Bridge Vibration Damper for Dog Cond. Milap No Fire Wage Connector for Moose to Moose Cond. Marc E-0/0, MT Fire Wage Connector for Zebra to Moose Cond. Marc MT 0 7 Repari Sleeve for Panther 0 SQMM Century E-0/0, No KV D/C G.I. Tower Materials suitable for ACSR Varsana Ispat E-77/, MT Panther Cond G.I. Bolt & Nuts for KV D/C GI Tower Materials Varsana Ispat MT suitable for ACSR Panther KV S/S Structure material. Varsana Ispat E-7/5, MT KV S/S Structure material. Varsana Ispat MT 5 KV S/S Structure material. Varsana Ispat MT G.I. Bolt & Nuts for KV S/S Structure. Varsana Ispat MT G.I. Bolt & Nuts for 0KV S/S Structure. Varsana Ispat MT G.I. Bolt & Nuts for KV S/S Structure. Varsana Ispat MT KV GI S/S Structure Material. Associated E-7/, MT Power G.I. Bolt & Nut for 00KV S/S Structure. Associated MT Power 5 G I Eearthing Strip 75MM X 0MM Akshar E-7/, No Order 0-.xls : ORDER ISSUED of

10 Name of Items Name of A/T. & REPAIR SLEEVE FOR Century E-0/, No PANTHER 0 SQMM (Addl order) 75 M S ANGLE 50 MM X Agrawal E-70/7, MT 50 MM X MM MS CHANNEL 00X50X MM Agrawal MT.5 MS CHANNEL Sanvijay E-70/, MT 5X5X MM SHORT ARMOUR RODS Aumni E-0/ PREFORMED FOR 97 DOG MS FLAT 75X0 MM Unique E-70 MT 0 MS ROUND BARS 0 Unique MT MM V, 00 AH Tubular type Lead Acid Battery Autobat E-7 with FRP stand & Accessories 0V, 50 AH Tubular type Lead Acid Battery Autobat E-7 with FRP stand & Accessories 50V, 50AH Lead Acid Battery with FRP Stand & Autobat E-7 Accessories 50V, 50AH Lead Acid Battery with FRP Stand & Autobat E-7 Accessories 50V, 00AH Lead Acid Battery with FRP Stand & Autobat E-7 Accessories ERECTION AND COMMISSIONING FOR Autobat E-7 0V/00AH BATTERY SETS ERECTION AND COMMISSIONING OF 0V/50AH Autobat E-7 BATTERY SET ERECTION AND COMMISSIONING OF 50V /50AH Autobat E-7 BATTERY SET ERECTION AND COMMISSIONING OF 50V/00AH Autobat E-7 BATTERY SET ERECTION AND COMMISSIONING OF50V /50AH Autobat E-7 BATTERY SET.00 0 V, 00AH Lead acid Battery with FRP stand HBL E- Addl. and accessories V, 0/5A -ph Battery Charger (With SCADA Panva E-7 Compatibility) V, 00 AH Tubular type Lead Acid Battery SERVILINK E-7 with FRP stand & Accessories.00 0V 50AH Plante type Battery with FRP Stand SERVILINK E-7 and Accessories V 50AH Plante type Battery with FRP Stand SERVILINK E-7 and Accessories.00 0V, 0/50A -ph Battery Charger(with SCADA SERVILINK E-7 compatibility) V, 0/0A -ph Battery Charger (withscada SERVILINK E-7 compatibility).00 50V, 00/0A -ph Battery Charger(with SCADA SERVILINK E-7 compatibility).00 50V, 50AH Lead Acid Battery with FRP Stand & SERVILINK E-7 Accessories.00 50V, 0/5A -ph SERVILINK E-7 Battery Charger (With.00 SCADA Compatibility) 50V, 0/5A -ph Battery Charger (Without SCADA SERVILINK E-7 Compatibility).00 ERECTION AND COMMISSIONING FOR SERVILINK E-7 0V/00AH BATTERY SETS.00 ERECTION AND OMMISSIONING OF 0V,50AH SERVILINK E-7 PLANTE TYPE BATTERY SET 0.00 ERECTION AND COMMISSIONING OF 0V,50AH SERVILINK E-7 PLANTE TYPE BATTERY SET.00 ERECTION AND COMMISSIONING OF 50V,50AH SERVILINK E-7 TUBULAR TYPE BATTERY SET.00 MS Rail 0KG IU quality as STANDARD E-70 MT per IRS, 0 Mtr. Long ENGG.00 MS FLAT 75X0 MM Sanvijay E 7/7, MT 57 MS RAIL 90/05 LBS Sanvijay MT M S ROUNDBAR 0MM Prakash Re- E 7/, MT Rollers MS ANGLE 50 X 50 X MM BHUWALKA E 7/5, MT 97 MS Beam X00 mm ( Mtrs) BHUWALKA MT 9 MS Beam 50 X50 mm Mtrs (+/- 50 mm) BHUWALKA MT 55 MS CHANNEL 00X50X MM BHUWALKA MT 5 MS CHANNEL 5X5X MM BHUWALKA MT 90 5 M S ROUNDBAR 0 MM Agrawal E 7/, MT MS FLAT 75X0 MM Orange City Steel E 7/, MT MS ANGLE 50 X 50 X Shree Vaishnav E 7/, MT MM G.I. BOLT & NUT FOR Associated E /7, MT //0 KV S/S STRUCTURE Power G.I. Structures for Associated MT //0/00 KV Sub Power Stations and Anchor Bolts & Lightning Mast 9 G.I. Bolt & Nut for //0 KV S/S Structure Vijay E /7, MT Transmission G.I. Structures for //0/00 KV S/S and Anchor Bolts & Lightning Mast Vijay Transmission MT 99 Order 0-.xls : ORDER ISSUED of

11 Name of Items Name of A/T. & 0 G I EARTHING STRIP JHT POWER E-99 MT 75MM X 0MM.00 GI EARTHING STRIPS JHT POWER E-99 MT 50MM X MM,.00 0V, 00 AH Tubular type Lead Acid Battery Autobat E-9/, with FRP stand & Accessories First charging and Commissioning V, 00AH Lead Acid Battery with FRP stand & Autobat Accessories First charging and Commissioning 7 50V, 50AH Lead Acid Battery with FRP stand & Accessories First charging and Commissioning Autobat 50V, 50AH Lead Acid Battery with FRP stand & Accessories First charging and Commissioning Autobat 0V, 00 AH Tubular type Lead Acid Battery with FRP stand & Accessories First charging and Commissioning 0V, 00 AH Tubular type Lead Acid Battery with FRP stand & Accessories First charging and Commissioning 50V, 50AH Lead Acid Battery with FRP Stand & Accessories + Erection and Commissioning Aaj Accumulators HBL E-9/9, 5.0. E-9/0, 5.0. Autobat E-7R/ 707, V, 0/5A -ph Battery Charger (With SCADA Panva E-7R/ 707, No Compatibility) 0.. Armour Rods Preformed for Dog Aumni E-0R/7, 97.. Armour Rods Preformed for Panther Aumni Midspan Compression Joint for Dog 5 SQMM Aumni No Single Suspension Hardware Normal for Dog Aumni No 7 Single Suspension Hardware Normal for Panther Aumni No 7 Single Tension Hardware Normal for Dog Aumni No 5 7 Midspan Compression Joint for Dog 5 SQMM Milap E-0R/7, No 57.. Single Suspension Hardware Normal for Dog Milap No 5 Armour Rods Preformed for Panther Rumika E-0R/7, set 5.. Single Tension Hardware Normal for Dog Rumika set Earthwire Suspension Clamp for 7/0 SWG 7/.5 EETEEL E-0R/75, No 55 MM.. Earthwire Tension Clamp for 7/0 SWG 7/.5 MM EETEEL No 57 Single Suspension Hardware Normal for Panther EETEEL No Cross by Clip for 7/0 Earth Wire Gayatri E-0R/7, No Single Tension Hardware Normal for Panther Krsna E-0R/7, No 9.. Stock Bridge Vibration Damper for Panther Cond. Krsna No V, 50AH Lead Acid Battery with FRP Stand & Accessories + Erection and Commissioning Servilink E-7R/057,.. 50V, 0/5A -ph Battery Charger (With SCADA Compatibility) 5 0V, 50AH Plante type Lead Acid Battery set with FRP Stand & Accessories + Erection and Commissioning 50V, 50AH Lead Acid Battery with FRP Stand & Accessories + Erection and Commissioning 50V, 50AH Lead Acid Battery with FRP Stand & Accessories + Erection and Commissioning Servilink No Servilink E-9/, 0.0. Amendment- Servilink Servilink 0V, 0A -ph Battery Charger (without SCADA) Servilink No 00 AH Battery 0V, 0/50A -ph Battery Charger(with SCADA) Servilink No 50V, 0/5A -ph Battery Charger (without SCADA) Servilink No 7 5 Fire Wage Connector for Panther to Panther Conductor Marc E-9/9, No 05 Fire Wage Connector for Zebra to Panther Conductor Marc No 77 Fire Wage Connector for Dog to Panther Conductor Marc No Fire Wage Connector for Zebra to Panther Conductor Ahura E-9/9, No 5 Copper Earth Bonds Tinned Braided Gayatri E-9/9, No Double Tension Hardware Normal for Panther Gayatri 70 Single Suspension Hardware Normal for Dog Gayatri 7 Single Tension Hardware without turn buckle for Gayatri 7 Zebra conductor 57 Double Suspension Hardware Normal for Dog Rumika E-9/9, Single Suspension Hardware Normal for Panther Rumika Single Tension Hardware Normal for Dog Rumika 97 Single Tension Hardware with turn buckle for Zebra Rumika conductor 5 Armour Rods Preformed for Panther Milap E-9/95, set Double Suspension Hardware Normal for Dog Milap set 000 Double Suspension Hardware Normal for Panther Milap set 0 Double Tension Hardware Normal for Dog Milap set 0 Order 0-.xls : ORDER ISSUED -05- of

12 Name of Items Name of A/T. & Single Suspension Hardware Normal for Panther Milap set 900 Single Tension Hardware Normal for Dog Milap set 000 Single Tension Hardware Normal for Panther Milap set 07 Stock Bridge Vibration Damper for Dog Cond. Milap No Midspan Compression Joint for Panther 0 SQMM Aumni E-9/9, No Single Suspension Hardware Normal for Panther Aumni set 70 Single Tension Hardware Normal for Dog Aumni set 00 0 Double Suspension Hardware Normal for Dog Milap E-7/0, set.0. Double Tension Hardware Normal for Dog Milap set 9 Single Suspension Hardware Normal for Dog Milap set 5 Single Suspension Hardware Normal for Panther Milap set 0 Armour Rods Preformed for Dog Aumni E-7/97, set Copper Earth Bonds Tinned Braided Aumni No 0 Earthwire Suspension Clamp for 7/0 SWG 7/.5 Aumni No MM Earthwire Tension Clamp for 7/0 SWG 7/.5 MM Aumni No 0 Midspan Compression Joint for Dog 5 SQMM Aumni No 7 Single Tension Hardware Normal for Panther Aumni set 09 Armour Rods Preformed for Panther Krsna E-7/50, set Copper Earth Bonds Tinned Braided Krsna No Cross by Clip for 7/0 Earth Wire Krsna No 0 Midspan Compression Joint for Panther 0 SQMM Krsna No 570 Stock Bridge Vibration Damper for Dog Cond. Krsna No 50 Stock Bridge Vibration Damper for Panther Cond. Krsna No 570 Repair Sleeve for Panther 0 SQMM EETEEL E-7/57, No Repair Sleeve for Dog 5 SQMM EETEEL No 70 Single Tension Hardware Normal for Dog EETEEL set 0 Double Suspension Hardware Normal for Panther Rumika E-7/509 set Double Suspension Hardware Normal for Zebra Rumika set Double Tension Hardware Normal for Panther Rumika set 90 Single Tension Hardware Normal for Zebra Cond Rumika set 00 5 Armour Rods Preformed for Dog Krsna E-9/ Double Tension Hardware Normal for Zebra Cond Krsna 50 Earthwire Suspension Clamp for 7/0 SWG 7/.5 Krsna No MM Earthwire Tension Clamp for 7/0 SWG 7/.5 MM Krsna No 90 Midspan Compression Joint 7/0 SWG 7/.5 MM Krsna No 5 Earthwire Single Tension Hardware Normal for Panther Krsna 900 Stock Bridge Vibration Damper for Dog Cond. Krsna No 000 Stock Bridge Vibration Damper for Panther Cond. Krsna No 700 Armour Rods Preformed for Dog Century E-9/ Midspan Compression Joint for Dog 5 SQMM Century No 5 Midspan Compression Joint 7/0 SWG 7/.5 MM Century No 5 Earthwire Repair Sleeve for Panther 0 SQMM Century No 5 Repair Sleeve for Dog 5 SQMM Century No 0 7 Armour Rods Preformed for Panther EETEEL E-9/ Cross by Clip for 7/0 Earth Wire EETEEL No Earthwire Suspension Clamp for 7/0 SWG 7/.5 EETEEL No 500 MM Earthwire Tension Clamp for 7/0 SWG 7/.5 MM EETEEL No Midspan Compression Joint for Dog 5 SQMM EETEEL No 7 Midspan Compression Joint for Panther 0 SQMM EETEEL No 0 Single Suspension Hardware Normal for Dog EETEEL 0000 Armour Rods Preformed for Dog Krsna E Addl/90, Repair Sleeve for Panther 0 SQMM Krsna No 5 Repair Sleeve for Dog 5 SQMM Krsna No 55 9 Shirting for Admn & Technical. Staff S. Kumars CE(P)/Proc/7 Pack (.0 Mtr/Pack) /e- 7/Uniform Cloth/S.Kumar/ 777 Shirting for Technical Staff (.0 Mtr/Pack) Date:7.0. S. Kumars Pack 0 Retro reflecting piping (0 Mtr Piping/Pack) 70 PC Trouser for All Male Staff (5.00 Mtr/Pack) Kurta for all female staff (.00 Mtr/Pack) S. Kumars Pack ALOK ALOK CE(P)/Proc/7 /e- 7/Uniform Cloth/Alok/775 Date: 7.0. Pack Pack 0 79 Order 0-.xls : ORDER ISSUED -05- of

13 Name of Items Name of A/T. & Salwar for all female staff ALOK Date: 7.0. Pack (.00 Mtr/Pack) Dupatta for all female staff ALOK Pack (.50 Mtr/Pack) Saree for all female staff ALOK Pack (5.50 Mtr/Pack) 5 Blouse for all female staff ALOK Pack (.00 Mtr/Pack) 5 7 Liberty make warrior Brand safety shoes Black sole ANMOL SAFTY 7/995, Pair : GP Antenna Midaas E-/577, V SMPS Power supply unit Midaas 0 RG- RF Cable Midaas 0 VHF Trans receiver set Midaas KV Line-CVT(00pf) with structure CGL E- 9/,dtd. 0 KV CVT (00pf) with structure CGL KV CVT (00pf) w/o structure CGL KV CVT (00pf) w/o structure CGL KV CC (00pf) w/o structure CGL KV CC (00pf) with structure CGL 7 KV CC (00pf) with structure ABB E- 9/,dtd KV Wave trap Areva E-/75,dtd RTU Panel Honeywell E-/0, dtd KV Wave trap (RO) Areva E-/, 9 0KV Wave trap (RO) Areva KV Wave trap (RO) Areva E-/7555, dtd DC IR Tester (0KV) M/s M Tekpro E-R/, Engg. Ltd Radio Link with Associated Equipments Midaas E-57/9,.0. Order 0-.xls : ORDER ISSUED -05- of

Name of Items Name of the Firm. 14, 1 Bus.

Name of Items Name of the Firm. 14, 1 Bus. A/T. & KV C&R Panels for line - 0V DC-Bus 0 KV C&R Panels for Transformer with differential Protection, 0 V DC Danish Private Limited, 4, Bus. E-05/575, Jaipur (Rajasthan) KV C&R Panel for Railway Line

More information

TECHNICAL SPECIFICATION (MAKER S LIST)

TECHNICAL SPECIFICATION (MAKER S LIST) TECHNICAL SPECIFICATION (MAKER S LIST) ENGINEERING DEPARTMENT WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Page 1 of 8 Maker s List MAKERS' LIST OF EQUIPMENT AND MATERIALS Note : 1. Equipment

More information

TECHNICAL SPECIFICATION MAKERS LIST 2016 (SUB-STATION)

TECHNICAL SPECIFICATION MAKERS LIST 2016 (SUB-STATION) TECHNICAL SPECIFICATION MAKERS LIST 2016 (SUB-STATION) CHIEF ENGINEER (ENGINEERING) WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED WBSETCL/ TECH SPEC / July 2016 Page 1 of 9 Makers List MAKERS'

More information

Larsen & Toubro Ltd. Power Transmission & Distribution - IC Project Name: RGGVY PH - II, Jaunpur. Vendor & GTP Approval Submission Vs Approval Status.

Larsen & Toubro Ltd. Power Transmission & Distribution - IC Project Name: RGGVY PH - II, Jaunpur. Vendor & GTP Approval Submission Vs Approval Status. Larsen & Toubro Ltd. Power Transmission & Distribution - IC Project Name: RGGVY PH - II, Jaunpur Vendor & GTP Approval Submission Vs Approval Status. S.No Material Name Sidhmukh Industries - Jhansi 29-Nov-13

More information

Material Base Rate DISTRIBUTION TRANSFORMER MSEDCL. Three Phase Dist. Transformer 16 KVA, 11/0.43 KV No

Material Base Rate DISTRIBUTION TRANSFORMER MSEDCL. Three Phase Dist. Transformer 16 KVA, 11/0.43 KV No POWER TRANSFORMER 1 2 3 1 Power Transformer 33/11 KV, 5 MVA. 3129000 2 Power Transformer 33/11 KV, 10 MVA. 5233333 3 Power Transformer 22/11 KV, 5 MVA (DY-11) 3095000 4 Power Transformer 22/11 KV, 10 MVA

More information

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS

PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS PROPOSED COST SCHEDULE OF MATERIALS FOR CONSUMER JOB AND OTHER JOBS Sl. 1 260200003A STEEL TUBULAR POLE SWAGED 11 MTR. LONG WITH BASE 7651.62 8034.20 8435.91 PLATE & CAP (IS2713/1980) BTM: 165.1X4.5MM-5.6MTR,

More information

List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole

List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole List of materials for 1Km. Of L.T line 1-Ph., 2-Wire AB cable (1 X 25+1X16) sq.mm using 8M X 200 KG. PSC Pole 1 L.T Stay set Complete Set 5 2 7/12 GI stay wire kg 50 3 Concreting of stay NO 5 4 Stay clamp

More information

S. K. Industrial Corporation

S. K. Industrial Corporation +91-8048763042 S. K. Industrial Corporation https://www.indiamart.com/skindlcorpn/ We are an ISO 9001 : 2008 certified company. We are manufacturing, exporting and supplying HT and LT transmission line,

More information

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA - 390 007 TENDER FOR Design,Engineering, manufacturing, supply, erection, testing & commissioning of 66

More information

TENDER SPECIFICATION. Rayalaseema Thermal Power Project (Muddanur) V.V.Reddy Nagar, Kalamalla Post,Cuddapah Dt, AP

TENDER SPECIFICATION. Rayalaseema Thermal Power Project (Muddanur) V.V.Reddy Nagar, Kalamalla Post,Cuddapah Dt, AP TENDER SPECIFICATION BHEL: PSSR: SCT: 1336 FOR Handling at Site Stores / Storage yard, Transportation to Site of Work, Erection, Testing and Commissioning of HT and LT Electrical Package for Unit 5-1x

More information

System Improvement Scheme(R&M) : FY

System Improvement Scheme(R&M) : FY GUJARAT ENERGY TRANSMISSION CORPORATION LTD System Improvement Scheme(R&M) : FY 2012-13 In GETCO network, large number of substations and lines are quite old, some of its equipments viz. CT s, PT s, Breakers,

More information

S P E C I F I C A T I O N

S P E C I F I C A T I O N T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/KKT-ELE/627 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING

More information

Item Code Description Unit Qty Total

Item Code Description Unit Qty Total UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories

More information

S P E C I F I C A T I O N

S P E C I F I C A T I O N T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/BHT-ELE/647 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING

More information

2 Unit Petrol Engine Spare parts kits for 4 WD Nissan Patrol

2 Unit Petrol Engine Spare parts kits for 4 WD Nissan Patrol 04-62-70001 4 WD NISSAN PATROL STATION WAGON SGL, 4500 cc 2 Unit Petrol Engine 04-62-70002 Spare parts kits for 4 WD Nissan Patrol 4 Set Station Wagon 04-62-70003 Belt-Fan 11720-03J00 4 Each 04-62-70004

More information

Set /

Set / BOQ and estimated Cost of Smart City Project, DHBVN, Gurgaon(prepared by DHBVN) Sr. NO. Description Unit Qty. Unit Supply Rate ref Total Supply cost Unit Erection Cost Total Erection Total Cost Rates Cost

More information

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal)

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) TRANSMISSION DIRECTORATE (A component of Power Transmission and Distribution Efficiency Enhancement Project BIDDING DOCUMENT FOR Procurement

More information

MAIN INCOMER -1 (500 KVA TRF.)

MAIN INCOMER -1 (500 KVA TRF.) Sr.No. DESCRIPTION MAKE QTY 1 MAIN L.T.PANEL Design, fabrication assembling, supply, installation, testing and commissioning of cubicale type LT panels floor mounted free standing suitable for 415 V 3

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender Notice No. 40/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Electrical work for the Clean Room at NCFlexE IIT Kanpur. Name of the Contractor S. No Description

More information

TENDER DOCUMENT PART-II

TENDER DOCUMENT PART-II 1 NATIONAL BANK FOR AGRICULTURE AND RURAL DEVELOPMENT TAMILNADU REGIONAL OFFICE TENDER DOCUMENT PART-II (PRICE BID) Supply, Installation, Testing and Commissioning of 25 kva DG Sets with Acoustic Enclosure

More information

T&D EQUIPMENT MARKET IN INDIA 2017

T&D EQUIPMENT MARKET IN INDIA 2017 New Research Report T&D EQUIPMENT MARKET IN INDIA 2017 Demand Outlook and Projections (till 2021-22) Report (PDF) Data-set (Excel) India Infrastructure Research T&D Equipment Market in India 2017 Table

More information

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal)

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) TRANSMISSION DIRECTORATE HETAUDA-DHALKEBAR-INARUWA 400KV SUBSTATION EXPANSION PROJECT BIDDING DOCUMENT FOR Procurement of Plant Design,

More information

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID S.NO. HEAD DESCRIPTION AMOUNT (Rs.) 1 A DG SETS & ACCESSORIES

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY Phone: +91 431 257 79 38 Fax

More information

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH

BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH SL NO. DESCRIPTION OF ITEM / WORK UNIT QTY PART - A : ELECTRICAL WORKS 1 1 Energy Meter Cubicle : a Fabrication, Supply, Installation, testing

More information

S P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836

S P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836 FOR OFFICIAL USE ONLY NOT FOR PUBLICATION TENDERER S COPY ORIGINAL COPY T E N D E R S P E C I F I C A T I O N TENDER NO. BHEL/ NR/SCT/ KOSTI /ELEC/ 836 FOR ERECTION, TESTING, COMMISSIONING TRIAL OPERATION

More information

Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu.

Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu. Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu. S.No Particulars Qty Unit Rate Rs Amount Rs Service Connection

More information

to UPS outgoing DB. c With 2 nos. 6 Sq.mm + 1 no. 2.5 Sq.mm. PVC insulated copper wire from UPS outgoing DB to CDB / Main panel to LDB /

to UPS outgoing DB. c With 2 nos. 6 Sq.mm + 1 no. 2.5 Sq.mm. PVC insulated copper wire from UPS outgoing DB to CDB / Main panel to LDB / Bill of Quantity for Electrical & Computer wiring works for Shifting of RACPC Jamshedpur to new location of Jamshedpur Branch Premises S.No. Item Description Qty. Rate Amount 1 UPS DB / COMPUTER DB Supply

More information

CURRICULUM VITAE. Having an experience and knowledge in Testing, Commissioning and Maintenance of power plant, substation and process plant.

CURRICULUM VITAE. Having an experience and knowledge in Testing, Commissioning and Maintenance of power plant, substation and process plant. CURRICULUM VITAE Personal details MANIKANDAN. Y manikandan.y@gmail.com Date of Birth : 17.07.1988 Nationality : Indian Sex : Male Marital Status: Single Passport No : J2470486 Current Visa : S pass Contact

More information

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement. INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side

More information

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY PURCHASE ENQUIRY Inquiry No : MDG/PUR/PKS/ENQ/Panels, Dated: Nov 3, 2014 Description Qty Specifications : Purchase Inquiry for Supply, installation and commissioning of Panels for PFP Expansion project.

More information

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate LAPSIPHEDI & CHANGUNARAYAN SUBSTATION CONSTRUCTION PROJECT (A Component of Power Transmission and Distribution

More information

TENDER SPECIFICATION

TENDER SPECIFICATION TENDER SPECIFICATION No. BHE/PW/PUR/SKT-ELE/1083 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING AND HANDING

More information

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE ENQUIRY PURCHASE ENQUIRY Inquiry No : MDG/PUR/PKS/ENQ/Panels, Dated: Jan 30, 2015 Description Qty Specifications : Purchase Inquiry for Supply, installation and commissioning of Panels for PFP Expansion project.

More information

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

Schedules 1 to 4, Lot B: Extension of the Lessos Substation 1.0 LIGHTNING ARRESTORS 1.1 ZNO lightning arrester, 192 kv rated voltage, 10 ka nominal discharge current 2.0 CAPACITIVE VOLTAGE TRANSFORMER ea. 45 2.1 220 kv capacitive voltage transformer 220/ 3 / 0.11/

More information

VOLUME :II PRICE BID BOOK NO.

VOLUME :II PRICE BID BOOK NO. T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/CHT-ELE/1127 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING

More information

SCHEDULE OF QUANTITY

SCHEDULE OF QUANTITY SCHEDULE OF QUANTITY ELECTRICAL WORKS PM PALEM BRANCH, VISAKHAPATNAM SL NO. DESCRIPTION OF ITEM / WORK UNIT Qty RATE AMOUNT PART - A : ELECTRICAL WORKS 1 Energy Meter Cubicle : 2 Emergency Off Box (Red

More information

PRICE BID - PART: I I

PRICE BID - PART: I I T E N D E R S P E C I F I C A T I O N NO: BHE/PW/PUR/PLT-ELE/603 FOR HANDLING AT SITE STORES/STORAGE YARD, TRANSPORTATION TO SITE OF WORK, COMPLETE ERECTION, CHECKING OF CALIBRATION, TESTING, COMMISSIONING

More information

Sub-Transmission & Distribution System

Sub-Transmission & Distribution System Sub-Transmission & Distribution System (33 kv and Below Systems) Cost Data FY 2016-17 1/58 COST DATA FOR FY- 2017-18 PREFACE 1 This Cost Data has been prepared in pursuance to regulation 13 of HPERC (Recovery

More information

Sub-Transmission & Distribution System

Sub-Transmission & Distribution System 1/58 Sub-Transmission & Distribution System (33 kv and Below Systems) Cost Data FY 2017-18 2/58 COST DATA FOR FY- 2017-18 PREFACE 1 This Cost Data has been prepared in pursuance to regulation 13 of HPERC

More information

Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises

Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises Bill of Quantity for Electrical & Computer wiring works for Shifting of SMECC Jamshedpur to Jamshedpur Branch Premises S.No. Item Description Qty. Rate Amount 1 Removing and Reinstallation of Main Incoming

More information

Estimate of Under Ground Electrification Work

Estimate of Under Ground Electrification Work S.No. Description of Items Unit Rate Qty Amount 1 Supply, Installation, Testing and Commissioning of 3C x 300 Sq. mm. Al. conductor, armoured, XLPE insulated, PVC sheathed, 11KV cable in ready made underground

More information

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

INDIAN INSTITUTE OF TECHNOLOGY KANPUR INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender tice. 21/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Construction of second floor above central block at ACES building (SH: Electrical works). Name of the

More information

S P E C I F I C A T I O NS

S P E C I F I C A T I O NS FOR OFFICIAL USE ONLY T FOR PUBLICATION TENDERER S COPY ORIGINAL COPY T E N D E R S P E C I F I C A T I O NS TENDER. BHEL/NR/SCT/ GGSRP BATHINDA / ELE / 659 FOR Erection, testing, commissioning, post commissioning,

More information

B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD

B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD B.O.Q FOR ELECTRICAL WORK (Including Fitting & Fixtures) OF STAFF QUARTERS AT BUUBANESWAR FOR UNITED INDIA INSURANCE CO. LTD Soubhagya Nayak Associates Plot No-736,Sector-3,Niladrivihar,Chandrasekharpur,Bhubaneswar.21

More information

Nissin s Products for Electric Railway System

Nissin s Products for Electric Railway System Ref. No. EKF120927-PRWS Nissin s Products for Electric Railway System KYOTO, JAPAN September, 2012 Introduction of Nissin Electric as Prime Supplier of Equipment for Electric Railway System in Japan Nissin

More information

PART A: FINANCIAL BID

PART A: FINANCIAL BID TENDER DOCUMENT FOR INTERIOR FURNISHING WORKS (excluding ELECTRICAL & DATA CABELING WORK) IN BANK OF INDIA BRANCH AT FARIDABAD,(SME BRANCH), HARYANA BANK OF INDIA, ZONAL OFFICE, STAR HOUSE, S.C.O. NO.

More information

TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES:

TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES: TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES: 1. SCOPE : This specification covers design, manufacturing, testing at manufacturer s works, inspection, packing & delivery of 11 KV Air Break

More information

Metal Clad VCBs ~ Mk1

Metal Clad VCBs ~ Mk1 Metal Clad VCBs ~ Mk1 DUVI 150/40 ROLL ON FLOOR VCBs Range: 6kV, 00A, 1.5kA, 12kV, 150A, 40kA ( 4A000A Bus-Bars ) ` Widest range for MV (up to 6kV) Distribution Networks Megawin make metal clad VCB Panels

More information

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

Tender Schedule. Sl. No. Particulars Quantity Unit Rate ` Tender Schedule Estimate for Electrical Works at Savalyapuram Branch(18901) Guntur(District). Sl. No. Particulars Quantity Unit Rate ` 1 Wiring for light point/ fan point/ exhaust fan point/ call bell

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

B.O.Q's FOR ELECTRICAL WORKS FOR BANK OF INDIA, COLLEGE ROAD, DHAKA BRANCH

B.O.Q's FOR ELECTRICAL WORKS FOR BANK OF INDIA, COLLEGE ROAD, DHAKA BRANCH B.O.Q's FOR ELECTRICAL WORKS FOR BANK OF INDIA, COLLEGE ROAD, DHAKA BRANCH S.NO. PARTICULARS QTY. UNIT RATE AMOUNT ELECTRICAL WORKS 1 LIGHT AND FAN POINT WIRING Suppling receving, storing, handling, fixing,

More information

BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH

BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH BOQ FOR ELECTRICAL WORK OF CANARA BANK RENGALI BRANCH 1. WIRING TO POINTS 1 Recess conduit wiring to light, ceiling fan, exhaust fan points with (2x1.5 sq mm + 1(1x1sqmm ) PVC single core copper FRLS wire

More information

/ १७८६ य २-२ / ४४ / ब ऑफर २०१७

/ १७८६ य २-२ / ४४ / ब ऑफर २०१७ -https://wrd.maharashtra.gov.in / १७८६ य २-२ / ४४ / ब ऑफर २०१७ :- (०७१७२)२२७३८२ फ - (०७१७२)२२७३८२ म :- mlidn2@rediffmail.com ०४ ०८ २०१७-442403 - म य य ब म य य य म य य य भ म र भ र य र म ब र ऑफर. ८ / २०१७-१८

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone:

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH

More information

: A N N E X U R E - "A" : (400KV Charanka substation) Supply of Major spares and devices

: A N N E X U R E - A : (400KV Charanka substation) Supply of Major spares and devices : A N N E X U R E - "A" : (400KV Charanka substation) Supply of Major spares and devices Sr. No. Particulars Unit Quantity (A) 400 KV Circuit Breaker One number of pole assembly for each type of Breaker

More information

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date:

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date: 10111. 4711M1 An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT ENQUIRY Corrigendum 1

More information

B.O.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH

B.O.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH B.Q ELECTRICAL WORK OF CANARA BANK, BUDHARAJA BRANCH SL.N 1. WIRING TO POINTS 1.0 Concealed conduit wiring to light, ceiling fan, exhaust fan points with (2x1.5 sq mm + 1(1x1sqmm ) PVC single core copper

More information

२१७१ २-१ ४४ २०१८ २-१ २१०९-४ २०१८ २९ ०६ २०१८ २ २ १२४९ २-१ ४४ २०१८ २१ ०७ २०१८ ३ २ १७०५ २ / -१ ४४ २०१८ १० १० २०१८ १ २ ३ २ ३ १३ २०१८-१९

२१७१ २-१ ४४ २०१८ २-१ २१०९-४ २०१८ २९ ०६ २०१८ २ २ १२४९ २-१ ४४ २०१८ २१ ०७ २०१८ ३ २ १७०५ २ / -१ ४४ २०१८ १० १० २०१८ १ २ ३ २ ३ १३ २०१८-१९ २१७१ २-१ ४४ २०१८ २ :- (०७१७२)२२७३८२-४४२४०३ - (०७१७२)२२७३८२ - mlidn2@rediffmail.com ३१ / १२ २०१८ - - १ २१०९-४ २०१८ २९ ०६ २०१८ २ २ १२४९ २-१ ४४ २०१८ २१ ०७ २०१८ ३ २ १७०५ २ / -१ ४४ २०१८ १० १० २०१८ ------000-----

More information

Gas Insulated Metal-clad Switchgear, HMGS!

Gas Insulated Metal-clad Switchgear, HMGS! Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Detail of Contracts Concluded during the month of February 2015 by TBMM, Noida

Detail of Contracts Concluded during the month of February 2015 by TBMM, Noida 344E169 [0] BSPGCL BARAUNI EXTENSION TPS AIR CONDITIONING EQUIPMENT LT 1-Dec-14 Two 12-Dec-14 1 1) Comfort Systems 344P211 6-Feb-15 Comfort Systems 11.62 31-Jul-15 against BSPGCL BARAUNI EXTENSION TPS

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) Rate per 90m Coil 0.75 7 770 810 920 28 12 1 12 1000 1050 1200 24 12 1.5 16 1470 1540 1760 16 10 2.5 22 2370 2490 2840 12 6 4 29 3490 3670 4190 8 4 6 37 5200 5460 6240 6 3 10 51 9140 9600

More information

Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal.

Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal. Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal. TENDER SCHEDULE -1-1 2 3 4 5 6 7 1 208 Point Wiring for light point/ fan point/ exhaust fan point/ call bell

More information

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA TENDER FOR GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA - 390 007 TENDER FOR Erection, Testing and Commissioning of all 32 KV & 66KV Substation Equipments provided

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

+91-8048571184 UB Exim Private Limited http://www.ubexim.in/ We are amongst the leading exporters, manufacturers, suppliers and traders, of this highly commendable and diverse range of Electrical Spares

More information

Schedule of Rate for Standard Stock Materials Common SR (11kV System)

Schedule of Rate for Standard Stock Materials Common SR (11kV System) Schedule of Rate for Standard Stock Materials Common SR 2016-17 (11kV System) Sl No Item No Name of the Material 1 Line Supports (POLES) Material Code UoM Common SR 2014-15 in Rs FORD Rates inclusive of

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT

More information

First Applications on AltaLink s Network. Roggero Ciofani, P. Eng. Colin Clark, P. Eng.

First Applications on AltaLink s Network. Roggero Ciofani, P. Eng. Colin Clark, P. Eng. First Applications on AltaLink s Network Roggero Ciofani, P. Eng. Colin Clark, P. Eng. Overview Technology Overview Applications and Alternatives Advantages Alberta Special Considerations Operational Implications

More information

TENDER DOCUMENT TENDER No.: NRO / CON / 592 / 537 FOR SUPPLY & INSTALLATION. DG Sets & Sychronising Panel

TENDER DOCUMENT TENDER No.: NRO / CON / 592 / 537 FOR SUPPLY & INSTALLATION. DG Sets & Sychronising Panel TENDER DOCUMENT TENDER No.: NRO / CON / 592 / 537 FOR SUPPLY & INSTALLATION OF DG Sets & Sychronising Panel FOR for multistoreyed Boy s Hostel SARDAR VALLABHBHAI NATIONAL INSTITUTE OF TECHNOLOGY, SURAT,

More information

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable

More information

ELE-PT-E-2003 Senior Electrical Protection & Commissioning Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS

ELE-PT-E-2003 Senior Electrical Protection & Commissioning Engineer PERSONAL DATA EDUCATION LANGUAGES COMPUTER SKILLS 104660-ELE-PT-E-2003 Senior Electrical Protection & Commissioning Engineer Holds a B. Sc. in Electrical Power & Machines Engineering and has about 14 years hands-on experience in low, medium voltage and

More information

Total Cost Abstract. Project Name : - RDPL, Jaipur. Grand Total

Total Cost Abstract. Project Name : - RDPL, Jaipur. Grand Total Project Name : - RDPL, Jaipur Total Cost Abstract S. No. Description Amount 1 Metering & Distribution Boxes 2 Earthing 3 Point Wiring & Fixtures 4 Data & Voice Grand Total Project Name : - RDPL, Jaipur

More information

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR AN ISO 9001 & 14001 COMPANY TENDER DOCUMENT TENDER No: DLI/CON/696/411 FOR SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 11/0.433KV INDOOR/OUTDOOR ELECTRIC SUBSTATION AND OTHER ASSOCIATED EXTERNAL ELECTRICAL

More information

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

LDC Pricelist. ( WEF 1st August 2017 ) POLYCAB 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured. INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded

More information

Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV).

Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV). Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV). Sr. No. Clause No Existing Proposed 1 8.0 Dischar ge device 2 15.0

More information

Max value Max life Range from. ($000) (Years) Pole Type

Max value Max life Range from. ($000) (Years) Pole Type Draft Handbook Vector Asset Description 1 Unit Maximum Maximum Life Max value Max life Max Asset Life Max Asset Life Range from Submitters Max Asset Life ($000) SUBTRANSMISSION Concrete Wood Concrete Wood

More information

Wires that don t catch fire

Wires that don t catch fire Wires that don t catch fire Havells range of heat resistant & flame retardant wires w.e.f. 1st July, 2017 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial

More information

HAVELLS INDIA LIMITED Corp. Office : QRG Towers, 2 D, Sector 126, Noida (UP), Ph : E Mail :

HAVELLS INDIA LIMITED Corp. Office : QRG Towers, 2 D, Sector 126, Noida (UP), Ph : E Mail : HAVELLS BRAND Power Cables, Solid Aluminum conductor up to 10 sqmm & balance stranded conductor, XLPE Insulated, cores laid up, PVC sheathed, Unarmoured/Armoured (Aluminium wire for single core up to 70

More information

DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA

DURESCA Busbar system. For indoor and outdoor applications, type DE / type DG DURESCA DURESCA Busbar system For indoor and outdoor applications, type DE / type DG DURESCA DURESCA Busbar system Swiss quality combined with global experience PRODUCT OVERVIEW Moser Glaser General description

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate (An Undertaking of Government of Nepal) Project Management Directorate KATHMANDU VALLEY EAST AND SOUTH DISTRIBUTION SYSTEM ENHANCEMENT PROJECT (A Component of ) BIDDING DOCUMENT FOR Enhancement of Distribution

More information

DETAILS OF CONTRACTOR CONCLUDED DURING THE MONTH jun08

DETAILS OF CONTRACTOR CONCLUDED DURING THE MONTH jun08 TYPE S S AND NAMES PARTIES S AND NAMES PARTIES T ER/ & DATE NAME OR CONTRA E ETION 7/9, FLUTE OR RIPPLED, ELEMENTS, R MANUFAURING IND 8 8 HI-TECH SWITCHGEAR PVT. L 98 E79 BREATHER ASSY TYPE, 8 8 YOGYA

More information

HT, LT U.G. cables & PVC insulated Al wire

HT, LT U.G. cables & PVC insulated Al wire HT, LT U.G. cables & PVC insulated Al wire Sl.No Name of the firm s particulars Valid upto 1 M/s. Gloster s Ltd., Kallakal(Vi), Toopran(MN), Medak district, Andra Pradesh ( Ph No: 91-80-2372 2274,2837

More information

Total Ex. Tax/VAT. (Rs.) (if any) in Rs. (Bought out/direct) length 587M 226M

Total Ex. Tax/VAT. (Rs.) (if any) in Rs. (Bought out/direct) length 587M 226M ORISSA POWER TRANSMISSION CORPORATION LIMITED Supply & Laying of 132 KV XLPE Double Circuit (4 cable per Circuit including one spare) underground 1000 Sq. mm annealed Copper XLPE EHV Cable with Associated

More information

TECHNICAL SPECIFICATIONS OF PCC PANEL

TECHNICAL SPECIFICATIONS OF PCC PANEL S. no. TECHNICAL SPECIFICATIONS OF PCC PANEL Technical parameters AS PER SPECIFICATION CONSTRUCTIONAL FEATURES TO BE FILLED BY THE SUPPLIER 1 Manufacturer s name To be specified by supplier 2 Rated operational

More information

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1 SF 6 gas insulated RMU SafePlus 24 kv 25.03.2010 SafePlus 24 kv SF6 gas insulated RMU 1 Secondary distribution 400 kv Transmission substation Transformer 40-70 kv 130 kv Main Substation Secondary distribution

More information

POWER SYSTEM CONSULTANTS POWER-LINKER

POWER SYSTEM CONSULTANTS POWER-LINKER GROUP POWER SYSTEM CONSULTANTS POWER-LINKER REFERENCE LIST : CONDITION MONITORING TESTING Given below is a list of Condition Monitoring Testing job executed by us: SR. 132.0 Petronet LNG Ltd., Dahej 131.0

More information

Amounts to be paid by the applicant for New Industrial Service Connections. (HT, i.e. CMD of 70 KVA & above)

Amounts to be paid by the applicant for New Industrial Service Connections. (HT, i.e. CMD of 70 KVA & above) s to be paid by the applicant for New Industrial Service Connections (HT, i.e. CMD of 70 KVA & above) 1. Development Charges : Per KVA of Contracted Maximum Demand (CMD) a. At 11 KV Potential : Rs. 1,200-00

More information

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate (An Undertaking of Government of Nepal) Project Management Directorate KATHMANDU VALLEY EAST AND SOUTH DISTRIBUTION SYSTEM ENHANCEMENT PROJECT (A Component of ) BIDDING DOCUMENT FOR Enhancement of Distribution

More information

OFF GRID SOLAR PV SYSTEMS

OFF GRID SOLAR PV SYSTEMS OFF GRID SOLAR PV SYSTEMS e n l i g h t e n i n g h o r i z o n s We thank you very much for your enquiry for OFF GRID Solar PV system and we are pleased to furnish our most competitive offer for the supply

More information

Machinery & Spareparts Centre

Machinery & Spareparts Centre +91-8048600257 Machinery & Spareparts Centre https://www.indiamart.com/machinery-sparepart-centre/ MSCKOLKATA SPARES ( OEM SPARES ) "Quality Products, Prompt Services, Trustful Relationships". About Us

More information

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv Three-phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv 06B1-E-0020 Small Space Requirement, High Reliability and Safety ー 72.5 to 145kV GIS, SDH714 The number of application

More information

NATIONAL POWER INDUSTRIES

NATIONAL POWER INDUSTRIES NSIC - CRISIL RATTING : SE 3 B NSIC - ICRA RATTING : SE 3 B C E MARKED PRODUCT Regd. Office : Administration Office Factory (1) Factory (2) Tele/Fax Mobile E-mail Website (Vyas Group Of Companies) Load

More information

+91-8071801149 Goyal Electricals And Electronics http://www.goyalshop.com/ We offer wide range of Electrical & Electronic Products to our clients. We do not compromise on quality and therefore our products

More information

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV Air Insulated Switchgear TAP17. Technical Data TGOOD MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)

More information

ESTIMATE FOR ELECTRICAL WORKS AT CHINCHOLI BRANCH

ESTIMATE FOR ELECTRICAL WORKS AT CHINCHOLI BRANCH ESTIMATE FOR ELECTRICAL WORKS AT CHINCHOLI BRANCH Sl. 1 L.T. CABLS:, Laying, Testing and Commissioning of 1.1KV class, LT underground XLPE insulated PVC sheathed, alluminium conductor, galvanized steel

More information