AUTOMATIC BATTERY CHARGER WITH CONSTANT VOLTAGE AND CURRENT
|
|
- Annabelle Hunter
- 5 years ago
- Views:
Transcription
1 Back CB2 AUTOMATIC BATTERY CHARGER WITH CONSTANT VOLTAGE AND CURRENT SUITABLE FOR LEAD BATTERIES FROM 12 TO 24Vdc. Automatic battery charger for complete and holding charge for all batteries, lead and nichel cadmium. Bitension, immediately adaptable to batteries from 12V and 24V Versatile and easy to manage. Electronic control of voltage and current of charge. Alarm signals in case of failure FILE VERSIONE DATA LINGUA PAGINA CB2PCITA B/03 29/09/05 ING 1 of 6
2 FUNCTIONING The CB2 automatic battery charger controls the voltage of the battery connected. If this voltage is lower than 1.7 V./c, it stops the complete charge and outputs a min. reset current. As soon as 1.7 V/c min. voltage is reached, this charger activate the max. complete charge set and self-adjusted. When 2 V/c charge is reached, a gradual decrease of current starts until the 2.25 V/c charge is complete (see fig. 1). When the battery is charged, CB2 accurately limits the holding current by compensating the battery self-discharge and possible consumption of the circuits connected. During its functioning, the charger holds accurately the parameters set even with mains variation within a range of +/- 15%. In addition to this, this battery charger is equipped with safety protections against mains overvoltages up to 4 KV. The delivery of dangerous voltages to the output and damages are prevented. The CB2-B battery charger controls the current and charge voltage accurately, thus assuring a battery long life. In fact, if these values are not controlled, the overcurrent and overvoltage would cause the electrolyte resolution to oxygen and hydrogen. In this way, the high quantity of oxygen would oxidize the inner plates, thus reducing its capacity and sulphation life. In order to avoid these drawbacks, CB2 carries out the following functions: In order to avoid any problem the CB2-C has got the following functions: Complete charge of flat batteries with current limitation and protection against short circuits; Automatic current reduction during the charge voltage increase; Charge current stop as soon as each cell reaches 2.25 V. (figure 1); Automatic compensation of the battery self-discharge and of other possible consumption; Protection against 1.65 V./c self-discharge with signaling and battery charger stop (figure 1); FUNCTIONAL DIAGRAM fe A = Ampere V/e = Volts/cell CHARGING CURRENT VOLTS / CELL V/c CB2PCING B/03 29/09/05 ING 2 of 6
3 SIGNALINGS pilot lamp: charge connected; pilot lamp: holding charge; pilot lamp: alarm; pilot lamp: connection to 24V. INSTALLATION AND USE CB2-B carries out the 12 V. and 24 V. battery recharge. Since the equipment is delivered with the battery charger set to 12 V., in order to recharge 24 V. batteries, it is necessary to change the position of jumpers (A, B, C, D) inside the battery charger (figure 2). Figure 2 SETTING TO 12 V SETTING TO 24V The connection of "A" and "B" jumpers to 24 V is signalled by led "24V POWER".!!!CAUTION!!! Since the connection state of C and D jumpers is not signalled externally, before supplying CB2-B with power, you are required to check the correct setting of jumpers. RATING TRIMMERS RIMMER DESCRIPTION RANGE P1 Max. current adjustment to 12 V 13-6A P2 Max. voltage adjustment to 12 V 15-10V P3 Max. voltage adjustment to 24V 30-22V P4 Max. current adjustment to 24V 11-4A P5 Overdischarge alarm level adjustment 13-9V CB2PCING B/03 29/09/05 ING 3 of 6
4 FUNCTIONAL BLOCK DIAGRAM TRANS. +B OVERDISCHARGE SIGNALING STARTING CIRCUITS CURRENT LIMITATION VOLTAGE CONTROL ALARM BATTERY Sh -B INSTALLATION It is necessary to install CB2-B so as to facilitate the convective circulation of the air -- which is heated by the dissipator --in order to allow a correct cooling of the power circuits (figure 5). UP YES NO AIR figure 5 CB2PCING B/03 29/09/05 ING 4 of 6
5 FIXING DIMENSIONS Dimensions in millimetres WIRING DIAGRAM Overdischarge alarm relay alarm battery + battery - battery neutral figure CB2PCING B/03 29/09/05 ING 5 of 6
6 CB2-B CB2-B FUSE CAPACITY POWER F1 F2 A 12V F2 A 24V 150VA 250VA 3A 3A 8A 16A 6A 8A TECHNICAL FEATURES MAX. POWER CONSUMED 150VA 250VA POWER SUPPLY VOLTAGE 220/380V 220/380V FREQUENCY 50/60HZ 50/60HZ INSULATION VOLTAGE >3KV >3KV BATTERY VOLTAGE 12V 24V 12V 24V MAX. CURRENT 8A 5A 13A 8A ALLARM LEVEL 10V 20V 10V 20V MAX. ALARM CURRENT 100 ma 100mA WORKING TEMPERATURE -20; +50 C WAVE FORM DOUBLE HALF WAVE PROTECTION AGAINST IN COMPLIANCE WITH CEI AND EIC DIMENSIONS ( WITH NO FASTENING WING SCREWS) OVERLOAD, SHORT CIRCUIT AND POLARITY INVERSION 110x120x WEIGHT 4400g 6500g 110x120x190 ORDER CODES: CB2/150 Automatic battery charger 12V 9A-24V 5A 150VA CB2/250 Automatic battery charger 12V 15A- 24V 9A 250VA CB2PCING B/03 29/09/05 ING 6 of 6
1RECHARGEABLE APPLIANCES
1RECHARGEABLE APPLIANCES 1 CAUTION Certain rechargers for small nickel cadmium batteries can be damaged if connected to the unit. Two types of equipment are particularly prone to this problem: 1. Small
More informationArt. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2
SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...
More informationSPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W
Page 1 / 7 Full operation without need of battery Two independent 48Vdc outputs for switching and control Local monitoring with 8 LEDs Remote monitoring with 4 alarm relays Monitoring and configuration
More informationINDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL
INSTRUCTION MANUAL FILE: 091-106-150-XX-120 DATE: 10-2-2009 REV: A INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 MODEL # 091-106-150-XX-120 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. 170
More informationSECTION DC POWER SUPPLY/BATTERY CHARGER
SECTION 26 33 05 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide the single-phase heavy-duty industrial battery charger and all accessories required, complete and operable, in accordance
More informationCONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...
CONTENTS SUBJECT PAGE TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS... 8 SEC 4 - BATTERY CHARGING NOTES... 9 SEC 5 - VERIFICATION
More informationGuardian Battery Charger Series. Installation and Operations Manual Section 75
Guardian Battery Charger Series Installation and Operations Manual 00-02-0615 02-29-08 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to
More informationPOWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE
8 POWER SUPPLIES Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p8-10 Perth (08) 9248 0410 Sydney (02) 9676 1671 Melbourne (03) 9706 4599
More informationAUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER
INSTRUCTION MANUAL FILE: IM_091-120-XX-XX-(XXX)(XX)_revA.P65 REV: A REVISED BY: PSS DATE: 07-19-13 AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER R MODEL #091-120-XX-XX-(XXX)(XX) 3 YEAR WARRANTY 170 Cherry
More informationINSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS
MANUAL NUMBER: 64073 REV: 2 DATE: October 3, 2006 INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS AMERICAN BATTERY CHARGING, INC. P.O. BOX 17040 28 MAPLE AVENUE SMITHFIELD,
More informationOWNER S MANUAL POWER INVERTER
OWNER S MANUAL POWER INVERTER PINV4 PINV5 PINV6 PINV4 600WATT PINV5 800WATT PINV6 1000WATT www.pyleaudio.com INTRODUCTION Thank you for purchasing the PYLE View DC to AC Power Inverter. The PINV4/PINV5/PINV6
More informationTECHNICAL DESCRIPTION
Electrical Energy Storage Tester EEST-511-S Semi-Automatic Charge-Discharge Battery Bench 1 channel 50 V / 100A (Ni-CD, Pb, Ni-Mh, Li-ion...) TECHNICAL DESCRIPTION To buy, sell, rent or trade-in this product
More informationPower Supply EL
General information: EL630-1203-7 has been specifically developed to meet the DC powering requirements for telecommunications, industrial and marine applications. The output is current limited, with short
More informationSentry Battery Charger. Installation and Operations Manual Section 75
Sentry Battery Charger Installation and Operations Manual 00-02-0616 03-03-08 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the right to change our
More informationBATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N
BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N OPERATING INSTRUCTIONS 1106 SPECIFICATIONS MODEL 120N 130N 210N 320E 410E 520N MAX CHARGE (AMPS) 15 15 25 35 35 50 MAX BOOST (AMPS)
More informationMPPT5012A-DUO-BT MPPT5025A-DUO-BT
MPPT Dual batterysolar controller User Manual MPPT5012A-DUO-BT MPPT5025A-DUO-BT Thank you very much for buying our product,please read thoroughly before using the prouuct Description of Functions 1. Increased
More informationMODEL ELC-12/40-CVM-D BATTERY CHARGER
NATIONAL RAILWAY SUPPLY MODEL ELC-12/40-CVM-D BATTERY CHARGER Installing, Operating and Service Instructions for the ELC-12/40-CVM-D Solid State Charger PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING
More informationTemperature Controllers
Controllers SCR Power Controllers Introduction to Silicon Controlled Rectifier (SCR) Power Controllers Features and Benefits of SCRs High reliability Because the SCR power controller is a solid-state device,
More informationDocument: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger
Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,
More informationTechnical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality
GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino
More informationTemperature Controllers
SCR Power Controllers Introduction to Silicon Controlled Rectifier (SCR) Power Controllers Features and Benefits of SCRs High reliability Because the SCR power controller is a solid-state device, it provides
More informationPhoenix Inverter
Manual EN Handleiding NL Manuel FR Anleitung DE Manual ES Appendix Phoenix Inverter 12 250 12 375 12 500 12 800 24 250 24 375 24 500 24 800 48 250 48 375 48 500 48 800 1. Safety instructions WARNING: ELECTRIC
More informationHEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N
HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N OPERATING & MAINTENANCE INSTRUCTIONS 1206 SPECIFICATIONS Supply Voltage 230 Max Charge (Amps) 60 (cont) Max Boost (Amps) 400 Boost/Charge (Volts)
More informationModels. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery
AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit
More informationPowerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)
A Complete solution for small battery-backed dc instrument power systems. DATASHEET Supply 12Vdc 8A or 24Vdc 6A loads Ideal for RTU s, dataloggers, remote field instrumentation, alarm systems, etc. where
More informationBMS 12/200 for 12,8 Volt lithium iron phosphate batteries Especially designed for vehicles and boats
BMS 12/200 for 12,8 Volt lithium iron phosphate batteries Especially designed for vehicles and boats www.victronenergy.com Why lithium-iron phosphate? Lithium-iron-phosphate (LiFePO4 or LFP) is the safest
More informationIMPORTANT. Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array.
EN Appendix Manual IMPORTANT Always connect the batteries first. Use for 12V battery system only 12V (36 cells) solar panel array. Use for 24V battery system only 24V (72 cells) solar panel array. BlueSolar
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series 10 20 30 40 kva 400 Vac CE Series 5 GE Consumer & Industrial SA General Electric Company CH
More informationProduct Guide. An Invensys company
Product Guide An Invensys company Contents Page I/ The principle of the gas-recombination battery... 2 II/ Charge characteristics... 4 III/ Electrical performance tables... 5 IV/ Battery calculations Float
More informationTechnical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work
Digital Energy Technical Data Sheet Uninterruptible Power Supply LPS33_010-020_S6_UPS floor_ge_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91
More informationVC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL
1. INTRODUCTION VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down DC-DC Converter has a digitally adjustable output in 0.2V increments. This
More informationINSTRUCTION MANUAL CAUTION
FILE: IM_091-128-12E-40-115 Rev B., 2-16-2006 INSTRUCTION MANUAL AUTO CHARGE ODY q AUTOMATIC BATTERY CHARGER MODEL #091-128-12E-40-115 for ODYSSEY AGM BATTERIES CAUTION This charger is calibrated to the
More informationVersatile and Rugged Industrial LIthium/LiPO Charger Series
Versatile and Rugged Industrial LIthium/LiPO Charger Series Description The M-series is an environmentally robust and sophisticated battery chargers with models supporting Lithium or LiPo batteries. With
More informationAC/DC Converter MBP250-2A13D13M
250W, 165-264VAC Input, Dual output AC/DC battery charging module power supply FEATURES Low stand-by power consumption, Maximum instantaneous power up to 350W With charging function, the 12V output Lead-acid
More informationAll In one uninterruptible power supply solutions
All In one uninterruptible power supply solutions For the life of your systems with Battery Care concept Integrated Electronic Solution Yet another strong proposition from Adelsystem, result of the continuing
More informationTECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)
TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power
More informationPower System Solutions (PSS)
About Power System Solutions mission The Power System Solutions Mission Statement To achieve customer satisfaction by providing innovative solutions to improve upon power quality, energy efficiency, and
More informationKC5 PV Charge Controller Instruction Manual
KC5 PV CHARGE CONTROLLER Instruction Manual Ningbo Komaes Solar Technology Co., Ltd. 1.Characteristics 1.1 PWM to prevent power loss. 1.2 Reasonable management for Batteries Charge & Discharge. 1.3 Working
More informationBellMega BM-510. Operation Manual Ver: 1.0 Rev: 1
BellMega BM-510 Operation Manual Ver: 1.0 Rev: 1 CONTENTS Page Description 1 Operation 2 Safety 2 Charging 3 Service / Calibration 3 Specifications 4 Description The BellMega is a continuity tester for
More informationHEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS
HEAVY DUTY BATTERY BOOSTERS / CHARGERS MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS 0614 Thank you for purchasing this CLARKE Battery Charger. These units are suitable for charging and boosting 12
More informationTECHNICAL BULLETIN Fig #1 - VRLA Battery Components. Intercell Welded Connection Strap joining neg. plates in parallel.
TECHNICAL BULLETIN 41-7264 IntegrIty testing The valve regulated lead acid (VRLA) battery has several components (Ref. Figure 1), all of which can deteriorate with storage conditions and normal as well
More informationElectronic Ballast EVG 2000-T
Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications
More informationAUTO CHARGE LPC SERIES
INSTRUCTION MANUAL FILE: IM_091-206-12_revB REV: B REVISED BY: THN DATE: 09-17-2012 AUTO CHARGE LPC SERIES MODEL #091-206-12 LPC STANDARD DISPLAY INPUT: 115 volt, 50/60 Hz, 13 amps OUTPUT: 80 AMPERES 3
More informationDIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications
DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry
More informationTechnical Data Sheets
Digit al Energy T M L P Seri es Di gi ta l Energy TM LP Series Digita l Energ y T M L P Se rie s GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationAlpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter
Alpha EM DC Technical Datasheet Compact DC Energy Meter ALPHA EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target
More informationPOWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System
POWER TROLLEY 8 Model: SINE 1548 Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System Version 07 CONTENTS Page 1. INTRODUCTION... 1 2. USING THE POWER TROLLEY.... 2 3. BATTERY BACKUP
More informationHE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual
HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual Page 1 of 10 CONTENTS 1. GENERAL...2 2. POWER REQUIREMENTS...2 2.1 HE-PSU(4.0) Input/Output Electrical Ratings...2
More informationNON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT
Model No. PEL00581 NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT 1 Please read these instructions carefully before starting installation and retain for future reference. The centre page
More informationCruising Charger Series OWNER S MANUAL
R Cruising Charger Series OWNER S MANUAL ON BOARD BATTERY CHARGERS Models DC Amperage No. Of Banks Volts 2614A 5,10 Amps 2 Bank 12/12 2614A-230 2621A 5,5,10 Amps 3 Banks 12/12/12 2621A-230 2622A 10,10
More informationTechnical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter
Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control
More informationControl panel. For 3 three-phase electric pumps with thermal protection and exchanger
AUTOCLAVES PRODUCTS Control panel For 3 three-phase electric pumps with thermal protection and exchanger General features: Electromechanic panel with electronic control Sequence exchanger for 2 electro
More informationBattery. Student booklet
Battery Student booklet Battery - INDEX - 2006-04-07-12:51 Battery Batteries are all over the place, in our cars, our PCs, laptops, portable MP3 players and cell phones. A battery is essentially a can
More informationSola/Hevi-Duty S3K Series Mini-Tower UPS
Sola/Hevi-Duty S3K Series Mini-Tower UPS GUIDE SPECIFICATIONS 700VA to 1600VA 120V models Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical
More informationEM DC Multi-Function DC Energy Meter
Analogue Meters With Moving - Iron Movement EM DC Compact DC Energy Meter Ziegler EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor
More informationCX-SERIES ADVANCED BATTERY CHARGER
CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...
More informationSolar Inverter Manual
Solar Inverter Manual Introduction SMPS series solar inverter power charging efficiency increased by 30%~60% than traditional controller charging. This inverter has automatic identification, three-stage
More informationCentral Battery Systems Loadstar AC/DC Systems
The Loadstar range of AC/DC central battery units comply with the latest relevant European and British standards. High quality, cost effective units provide secure sources of emergency power for escape
More informationCENTRAL BATTERY UNIT. Installation and maintenance instructions TKT3122
VOT3122 CENTRAL BATTERY UNIT Installation and maintenance instructions TKT3122 KEEP IN A SAFE PLACE FOR LATER USE TKT3122 PRODUCT DESCRIPTION Table of contents REV.6; EN; 11.03.2011 PHO Page 2 1. Product
More informationSola 3000 Guide Specifications
Sola 3000 Guide Specifications CSI 16610 - Static Uninterruptible Power Supply Systems - Sola 3000 Guide Specifications for a 700 to 2200 VA Single - Phase Uninterruptible Power Supply System 1.0 GENERAL
More informationMODEL No. BC 700. Par t No OPERATING & MAINTENANCE INSTRUCTIONS
BATTERY BOOSTER/CHARGER MODEL No. BC 700 Par t No.6260025 OPERATING & MAINTENANCE INSTRUCTIONS Congratulations on the purchase of your new CLARKE, START N CHARGE 700, BATTERY BOOSTER/CHARGER. This 3 Phase
More informationSail Away with Peace of Mind. Dolphin Series II Smart Battery Chargers
Sail Away with Peace of Mind Dolphin Series II Smart Battery Chargers DOLPHIN II SMART BATTERY CHARGERS OVERVIEW Small Power Chargers (small frame housing) Featuring two selectable outputs for charging
More informationOD DIGITAL DISSOLVED OXYGEN CONTROLLER POLAROGRAPHIC CELL
UNI EN ISO 9001:2000 CERT. N. 9115 BCEL INSTRUCTION MANUAL OD 265.2 DIGITAL DISSOLVED OXYGEN CONTROLLER POLAROGRAPHIC CELL Rev. B - 03/07 B&C Electronics Srl - Via per Villanova 3-20040 Carnate (Mi) -
More informationIntelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting
NRG Intelligent Engine Start Battery Charger The Smart Choice for Mission-Critical Engine Starting Fast, accurate, mission-critical charging gives best starting reliability Replace nearly any charger without
More informationElmdene International Ltd
1 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44(0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk 13.8Vdc Switch Mode Power Supply GEN3-08-y
More informationC&D VRLA Batteries Extended Run Time for Small UPS Machines
TECHNICAL BULLETIN 41-7954 C&D VRLA Batteries Extended Run Time for Small UPS Machines 41-7954/0112/CD www.cdtechno.com Small UPS machines, in the range of 400 to 2500 VA, are typically used to provide
More informationAL600ULX Series. Power Supply/Charger Installation Guide
AL600ULX Series Power Supply/Charger Installation Guide Models Include: AL600ULX - Single Output AL600ULPD4 AL600ULPD4CB - Four (4) Fused Outputs - Four (4) PTC Outputs AL600ULPD8 AL600ULPD8CB - Eight
More informationPhocos CML-V2. Solar charge controller. User Manual (English) Dear customer,
Phocos CML-V2 Solar charge controller User Manual (English) Dear customer, Thank you very much for buying this Phocos product. Please read the instructions carefully and thoroughly before using the product.
More informationILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase
ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA Illuminator Series LV Single Phase ILLUMINATOR SERIES LV The Illuminator Series LV is a 175VA-750VA fast transfer Emergency Lighting
More informationPressure switch hex 27
Pressure switch Changeover switch with silver or gold contacts Easily adjustable switching point. Factory adjustable hysteresis (except type 0140/014. High overpressure safety and long life even under
More informationPure Sine Wave Power Inverter SSW A SSW A SSW A SSW A SSW A
Pure Sine Wave Power Inverter SSW-350-12A SSW-600-12A SSW-1000-12A SSW-1500-12A SSW-2000-12A Owner's Manual Please read this manual before installing your inverter 1 IMPORTANT SAFETY INSTRUCTIONS THIS
More informationUSER MANUAL. Copyright 2006, PowerStation, LLC All rights reserved MODEL: PS5000M
USER MANUAL Copyright 2006, PowerStation, LLC All rights reserved MODEL: PS5000M CONTENTS Warning Information 1 3 Introduction 4 Features 4 Getting to know your PS5000M 5-6 Operation 7 Charging before
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationRVS-DN Digital Reduced Voltage Motor Starter
RVS-DN Digital Reduced Voltage Motor Starter Specification Guide Specification Guide Contents 1.0 Introduction 2.0 Specifications 2.1 Standard Performance Features 2.2 Standard Protection Features 2.3
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationTechnical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis
Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control
More informationMINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS
MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS Sec# Table of Contents Pg# 1 INSTALLATION 1.1 Receiving 1 1.2 Location 1 1.3 Line Voltage Adjustments 2 1.4 A.C. Service Requirements
More informationTECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT
TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT 1.0 PURPOSE: 1. To charge the battery bank through Solar PV source and AC supply. 2. To invert and produce utility quality sine wave. 3. Inverters
More informationApplication Engineering
Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply LP 33 Series / 10 20 30 kva 400 VAC CE Series 4 SGT4000_010-020-030 GE_01 Manufactured by: GE
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SitePro 400 & 500 kva 400 VAC CE Series 6 Manufactured by: GE Digital Energy General Electric
More informationSoft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP
Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user
More informationShort form catalogue. Motor protection & control
Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59
More informationPOWER-HUB 12 VOLT PORTABLE POWER STATION
POWER-HUB 12 VOLT PORTABLE POWER STATION P/No. PH125 WARNINGS Risk of explosive gas. Working in the vicinity of a lead-acid battery can be dangerous Batteries might release explosive gases during normal
More informationmodel ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION
MODEL: PS600 HZ: 60 A model ps600 installation and service manual for federal model ps600 FEDERAL SIGNAL CORPORATION POWER SUPPLY VOLTS: SERIES: 120VAC FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A.
More informationApplication Engineering
Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor
More informationU N I T Y / Three-Phase Uninterruptible Power Systems UT310, UT315, UT320, UT Hz
U N I T Y / I Three-Phase Uninterruptible Power Systems UT10, UT15, UT0, UT0 60 Hz Planning and Installation Manual LTS-071D Copyright 1995, Best Power Technology, Incorporated IMPORTANT SAFETY INSTRUCTIONS
More informationApplications DC Motors Stepping and Servos Solenoid Valves Relays Lamps and Signal Systems Input to On-Board Regulators Some Floppy Disc Drives.
Applications DC Motors Stepping and Servos Solenoid Valves Relays Lamps and Signal Systems Input to On-Board Regulators Some Floppy Disc Drives a c d b e Selection Guide (partial) Part No. Case Size Output
More informationOperating Instructions for Your Cobra 300 Watt POWER INVERTER M ODEL CPI 300. Nothing comes close to a Cobra
Operating Instructions for Your Cobra 300 Watt POWER INVERTER M ODEL CPI 300 Nothing comes close to a Cobra 00 300 Watt POWER INVERTER MODEL CPI 300 Congratulations Thank you for purchasing the CPI 300
More informationService Department. Other Service Items. Battery Basics. How Do Lead Acid Batteries Work? Battery Construction. Service Address
1 of 5 12/6/2012 11:57 AM Home Contact Us Site Ma About Us RV Specialty Marine Medical Sales Services Customers News Manufacturing American Made Products for RV, Specialty, Marine and Medical Industries
More informationUser s Manual. Automatic Switch-Mode Battery Charger
User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service
More informationVC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL
1. INTRODUCTION VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down 24V to 12V DC-DC Converter has a programmable 12.0 to 15.0V output in
More informationUser Manual WT Combi-S Pure Sinus Wave Inverter
User Manual WT Combi-S Pure Sinus Wave Inverter Contents 1. Important Safety information 1.1. Safety Information part 1 1.2. Safety information part 2 2. General Features 2.1. Product overview 3. Connection
More informationBATTERY/BOOSTER CHARGER. Model No: BC100N Part No: OPERATING & MAINTENANCE INSTRUCTIONS
BATTERY/BOOSTER CHARGER Model No: BC100N Part No: 6210101 OPERATING & MAINTENANCE INSTRUCTIONS 0906 Specifications Max Charge... 15Amps Duty Cycle... 100% 10A Arith. Max Boost... 100Amps Boost/Charge...
More informationVRLA Batteries. Battery Installation And Start up Guide
TECHNICAL MANUAL 41-7525 VRLA Batteries 26-206 Ampere-Hour Capacity Battery Installation And Start up Guide (For Rack Mounted Systems) 41-7525/0514/CD www.cdtechno.com Table of Contents 12V VRLA Battery
More information100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY
100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY CONTENTS Warranty 2 Introduction 3 Environmental protection 3 Specifications 3 General safety warnings and instructions 4 Know your product
More informationTECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)
TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5
More informationPRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY
Sheet 1 of 5 Order Number Serial Number PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Issue Date Level B 27/05/1999 Initial issue. Summary of changes Due to RMS continuous product improvement policy
More information