1 Sola 3000 Guide Specifications CSI Static Uninterruptible Power Supply Systems - Sola 3000 Guide Specifications for a 700 to 2200 VA Single - Phase Uninterruptible Power Supply System 1.0 GENERAL 1.1 SUMMARY This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty single-phase, solid state, uninterruptible power system. The uninterruptible power system, hereafter referred to as the UPS, shall provide high-quality AC power for electronic equipment loads. 1.2 STANDARDS The UPS shall be designed in accordance with the applicable sections of the current revision of the following documents. Where a conflict arises between these documents and statements made herein, the statements in this specification shall govern. 120V Units UL Standard 1778 FCC Part 15, Class A IEEE 587, Category A C-UL (to CSA 22.2 No ) National Electrical Code (NFPA 70) ISTA Project 1A 230V Units EN (Incorporating EN60950) TUV/GS Listed EMC- EN (Incorporating) EN 55022, Class B IEC 801-2, Level 4 IEC 801-3, Level 3 IEC 801-5, Level 2 CE compliance mark, For both Low Voltage and EMC Directives ISTA Project 1A 1.3 SYSTEM DESCRIPTION Modes of Operation The UPS shall be designed to operate as a line interactive system in the following modes: A. Normal - The critical AC load is continuously supplied with filtered power. The battery charger shall maintain a float-charge on the battery. 1

2 B. Voltage Boost/Buck - During input power source abnormalities (sags and swells), the AC output power shall be corrected by means of boost (sag correction) or buck (swell correction) compensation taps. Operation of the compensation taps shall be seamless and automatically maintain the proper output voltage for the connected critical equipment. The compensation taps shall be designed for indefinite operation to their limits, operation of the compensation taps shall not discharge the battery. C. Battery - When the input power source exceeds the parameters defined in section A, the critical AC load shall be supplied power by the inverter which obtains its power from the battery. Detection and transfer time shall be 2-6 ms. D. Recharge - Upon restoration of utility the input power source within specified parameters, the critical AC load shall be supplied with filtered power and the battery charger shall simultaneously recharge the battery. E. Automatic Restart- Upon restoration of the input power source, after a complete battery discharge, the UPS shall automatically restart and supply filtered power to the critical load. The bi-directional converter shall simultaneous recharge the battery. F. Dark Start- The UPS shall be capable of starting without input power available. The unit shall start up and operate from the battery Design Requirements A. Voltage: Input/Output voltage specifications of the UPS shall be: Input 120V units: 0 to 160 VAC, 50/60 Hz, single-phase, 2-wire-plus-ground. 230V units: 0 to 300 VAC, 50/60 Hz, single phase, 2-wire-plus-ground Output 120V units: VAC, 50/60 Hz, single-phase, 2-wire-plus-ground. 230V units: VAC, 50/60 Hz, single-phase, 2-wire-plus-ground B. Output Load Capacity: Maximum specified output load capacity of the UPS, regardless of load power factor, shall be: 700VA/450W 1000VA/670W 1400VA/950W 2200VA/1600W C. Internal Battery: The battery shall consist of valve regulated, lead acid cells. D. Backup Time: 5 minutes at full load with ambient temperature at 25 deg C (77 deg F). E. Battery Recharge: he recharge time shall be 3 hours (5 hours for 1400 VA / 120 VAC) to 95% capacity after discharged into a full load Performance Requirements AC Input to UPS A. Voltage Configuration: 120VAC; +23%, -25% (90 to 148 VAC), single phase, 2-wire-plus-ground 230VAC; +17%, -27% (166 to 272 VAC), single phase, 2-wire-plus-ground 2

3 B. Frequency: UPS auto senses input frequency and will operate within the following frequency specifications. 50 Hz Units: Hz 60 Hz Unit: Hz When the input frequency exceeds these parameters, the UPS shall operate from the battery. C. Surge Protection: 120 VAC Nominal units shall Sustain input surges without damage per criteria listed in ANSI C IEEE 587, Category A. 230 VAC nominal units shall sustain input surge without damage per criteria Listed in IEC 801-5, Level 3. D. Input: 120 VAC units The 700 VA model shall have a detachable input cord. The detachable input cord with the 700 VA shall be 6.0 feet (1.8 meters) in length, measured between the inside edges of the connectors. The detachable cord shall contain an IEC A type receptacle on one end and a NEMA 5-15 plug on the other. The 1000 and 1400 VA models shall have an attached cord with a NEMA 5-15P plug. The 2200 VA model shall have an attached cord with a NEMA L5-30P plug. The attached cord shall be 6.0 feet (1.8 meters) in length, measured from the outside edge of the UPS case to the nearest edge of the plug connector. 230 VAC units The input for the 700, 1000, and 1400 VA models shall have a IEC A recessed plug. The input for the 2200 VA model shall have an IEC A recessed plug AC Output, Normal Operation A. Voltage Configuration: 120V unit: VAC, single-phase, 2-wire-plus-ground. 230V unit: VAC, single-phase, 2-wire-plus-ground. B. Voltage Regulation: 120V Units: +10/-14% 230V Units: +8/-19% C. Frequency Regulation: 50 Hz Operation: 50Hz +/- 10% 0 Hz +/- 8% D. Load Power Factor Range: 0.5 lagging to 1.0 unity E. Output Power Rating: Maximum specified output load capacity of the UPS, regardless of load power factor, shall be: 700VA/450W 1000VA/670W 1400VA/950W 2200VA/1600W F. Overload Capability: 110% for 5 minutes 3

4 AC Output, UPS Inverter A. Voltage Configuration: 120 or 230VAC units, single-phase-2-wire- plus-ground. B. Voltage Regulation: +/- 7% RMS for entire battery voltage range. C. Frequency Regulation: +/- 0.5 Hz D. Frequency Sync. Rate: +/-5 Hz E. Frequency Slew Rate: 1 Hz per second F. Voltage Distortion: Resistive Loads: 10% before (2) minute warning; 15% after pre-alarm Switching Mode Power Supply (SMPS): 16% before 2 minute warning, 20% after pre-alarm G. Load Power Factor Range: 0.5 lagging to 1.0 unity H. Output Power Rating: Maximum specified output load capacity of the UPS, regardless of load power factor, shall be: 700VA/450W 1000VA/670W 1400VA/950W 2200VA/1600W I. Overload Capability: 110% for 30 seconds J. Voltage Transient Response: +/- 7% maximum for 20%-100%-20% load step K. Transient Recovery Time: To within nominal voltage within 30 milliseconds. 1.4 ENVIRONMENTAL CONDITIONS A. Ambient Temperature Operating: 0 deg C to +40 deg C (+ 32 deg F to deg F) for altitudes 0 to 1500 meters (0 to 5000 ft.) above sea level 0 deg C to +35 deg C (+ 32 deg F to + 95 deg F) for altitudes 1500 to 3000 meters (5000 to 10,000 ft.) above sea level 25 deg C (+ 77 deg F) for optimum battery performance Storage: 15 deg C to +50 deg C (+ 5 deg F to +122 deg F) 20 deg C (+ 68 deg F) for optimum battery storage. B. Relative Humidity Operating: Storage: 0 to 95% non-condensing 0 to 95% non-condensing 4

5 C. Altitude Operating: Storage: 3000 m (10,000 ft max.) without power derating when operated within the temperature range specified in 1.4.A m (32,808 ft max) D. Audible Noise Noise generated by the UPS during any mode of operation shall not exceed 45 db measured at 1 meter from the surface of the UPS. 1.5 USER DOCUMENTATION The specified UPS shall be supplied with one (1) user s manual. Manuals shall include installation drawings and instructions, a functional description of the equipment with block diagrams, safety precautions, illustrations, step by step operating procedures, and general maintenance guidelines. 1.6 WARRANTY The UPS manufacturer shall warrant the UPS against defects in materials and workmanship for two (2) years. The warranty shall cover all parts and labor. An optional one (1) or three (3) year extended warranty shall be available from the manufacturer. 1.7 QUALITY ASSURANCE Manufacturer Qualifications A minimum of twenty years experience in the design, manufacture, and testing of solid-state UPS systems is required. The manufacturer shall be certified to ISO Factory Testing Before shipment, the manufacturer shall fully and completely test the system to assure compliance with the specification. These tests shall include operational discharge and recharge tests on the internal battery to assure performance. 2.0 PRODUCT 2.1 FABRICATION Wiring All materials and components making up the UPS shall be new, of current manufacture, and shall not have been in prior service except as required during factory testing. All active electronic devices shall be solidstate. All relays shall be provided with dust covers. Wiring practices, materials, and coding shall be in accordance with the requirements of the standards listed in section 1.2 and other applicable codes and standards. All power wiring shall be copper. 5

6 2.1.3 Cabinet The UPS unit, comprised of: bi-directional converter, regulating circuit, and battery consisting of the appropriate number of valve regulated battery cells, shall be housed in either a free-standing NEMA type 1 enclosure and shall meet the requirements of IP21. The UPS cabinet shall be cleaned, primed, and painted with the manufacturer's standard color. Dimensions shall be: 700 VA 1000 VA 1400 VA 2000 VA 5.51 (140mm) W x (366mm) D x 7 (178mm) H 6.77 (172mm) W x (465mm) D x 8.94 (227mm) H 6.77 (172mm) W x (465mm) D x 8.94 (227mm) H 7.56 (192mm) W x (502mm) D x (318mm) H Cooling The UPS shall be forced air cooled when required. Air intake shall be through the sides of the unit and exit out the rear. 2.2 COMPONENTS Power Train A. Input Protection The UPS shall have built-in protection against undervoltage, overcurrent, and overvoltage conditions including low-energy lightning surges, introduced on the primary input power source. The 120 VAC UPS modes shall sustain input surges without damage per criteria listed in ANSI C ; IEEE 587, Cat. A. The 230 VAC UPS modes shall sustain input surges without damage per criteria listed in IEC , Level 3. B. Bi-Directional Converter The bi-directional converter shall denote the solid-state equipment and controls to convert AC power to regulated DC power for battery charging and convert DC power from the battery to regulated and conditioned sinewave AC power for supporting the critical load. The bi-directional converter shall be transistorized, pulse width modulated (PWM) design. The bi-directional converter shall operate in the following modes: 1. In the normal mode of operation, the bi-directional converter shall maintain the battery system at a float charge. 2. In the battery mode of operation, the bi-directional converter shall convert DC power from the battery to regulated and conditioned sinewave AC power for supporting the critical load. 3. In the recharge mode of operation, the bi-directional converter shall convert AC power to regulated DC power to recharge the battery to 95% capacity within three (3) hours ((5) hours for 1400 VA / 120VAC) after discharge into a full load. C. Battery Recharge The UPS shall maintain a battery recharge rate designed to prolong battery life. The battery charger shall maintain a constant voltage and current charge and maintain the battery in a fully charged state. Recharge time shall be three (3) hours ((5) hours for 1400 VA / 120VAC) maximum to 95% capacity after discharge into a full load. 6

7 D. Bi-Directional Converter DC Protection The bi-directional converter shall be protected by the following DC shutdown levels: E. Output Protection DC Undervoltage Shutdown (End of Discharge) DC Undervoltage Warning (Low Battery Reserve); factory set at 2 minutes For "Faults" indications within the UPS; including short circuits and overloads. The UPS shall employ the following overcurrent protection methods depending upon mode of operation: Normal Mode - The UPS shall employ a Fuse ( with spare) for the 700VA or circuit protector (resettable) 1000, 1400,and 2200VA. Battery Mode - Electronic Current Limit F. Overload The UPS shall be capable of supplying current and voltage for overloads exceeding 100% and up to 110% of full load current for 5 minutes in normal mode. A visual indicator and audible alarm shall indicate overload operation. The bi-directional converter (Battery operation) shall be capable of supplying current and voltage for overloads exceeding 100% and up to 110% of full load current for 30 seconds. For greater currents or longer time duration, the UPS shall shut down to prevent damage to components and the connected equipment. G. Output Frequency The output frequency during normal operation shall follow the incoming power frequency within a +/- 8% (for 60 Hz operation) or +/- 10% (for 50 Hz operation) window. The output frequency of the bi-directional converter shall be controlled by an oscillator. The oscillator shall hold the output frequency to +/- 0.5 Hz for steady state and transient load conditions. H. Battery Over Discharge Protection To prevent battery damage from over discharging, the UPS control logic shall automatically raise the shutdown voltage set point based on lighter loading Display and Controls A. General The UPS shall provide the operator with both visual and audible status indicators. Visual indicators shall consist of two (2) individual LED s, one to indicate utility/battery operation and one to indicate UPS buck/boost condition. Visual indicators shall also include one (1) row of four (4) LED s to indicate the load/battery level. B. Utility/Battery Status Indicator This LED shall be used to provide operation mode status of the UPS. When operating from input AC power and the main On/Off switch is on, this LED shall illuminate green. In the absence of input AC power (battery mode operation) this LED shall flash on/off for 1.0 second, every second. C. Utility High/Low status indicator This LED shall be used to provide buck/boost operation of the UPS, and shall illuminate amber (yellow). 7

8 D. Fault status indicator The UPS shall flash on/off (0.5 second, every second) the C (second from top) load/battery level indicator to indicate a UPS fault condition. In addition to the C (second from top) load/battery level LED being illuminated (flashing), one or more additional load/battery level LED segments will also be illuminated to provide a diagnostic aid to the operator, as described below: 25% 50% 75% 100% Utility Utility H/L A B C D bottom top Load/battery level A. UPS Fault Fan Fail / Overcharge A&D. UPS shutdown due to over temperature condition D. UPS shutdown due to output overload A&B. UPS shutdown due to main Relay Failure / Output short circuit B. UPS failed battery test B&D. UPS shutdown due to command from communication (RS232 or SNMP) port E. Load/Battery Level Indicator This four (4) segment LED bar shall be used to indicate the relative load on the UPS output and battery capacity level, determined by the mode of operation. The LED s shall illuminate green whenever the UPS is operating from input AC power or when the UPS is operating from battery power. During utility operation, the UPS output load level will be indicated in 25% increments as follows: 1% to 25% 26% to 50% 51% to 75% 76% to 100% To indicate operation with more than 110% load the top most LED indicator will flash on and off for 0.25 second, every second in addition to all segments being illuminated. An audible alarm shall also enunciate. During battery operation the UPS battery capacity level will be indicated in 25% increments as follows: 1% to 25% 26% to 50% 51% to 75% 76% to 100% To indicate low battery condition (approximately 2 minutes remaining) the Bottom most LED indicator will flash on and off for 0.5 second, every second. An audible alarm shall also enunciate a different tone (than the on battery tone) to indicate low battery condition 8

9 F. Audible Alarm An audible alarm shall be used in conjunction with the visual indicators to indicate to the operator a change in UPS operating status. The audible alarm shall enunciate as follows: Utility Line Loss Low Battery UPS Fault Overload Battery replacement 0.5 second beep, every 10 seconds 2 second beep, every 5 seconds Continuous 0.5 second beep, every 0.5 seconds 2 second beep, every 60 seconds All audible alarms shall be silenceable except low Battery Condition. Once silenced, the audible alarm shall not sound, until a new alarm condition is present. G. Controls The UPS shall contain front panel mounted main On/Off and alarm silence/manual battery test switches. The UPS shall also contain a microcontroller based monitoring and controls for reliable operation. The alarm silence/manual battery test switch shall be dual function that operates in the following manner: H. Alarm Silence Normal Mode: Battery test Battery Mode: Alarm silence Automatic Self Diagnostic Test The UPS shall perform three (3) different automatic self diagnostic tests as described below: A. Automatic self diagnostic test: Power ON The UPS must qualify the input power source voltage before initiating start-up. Qualification of the input power source shall consist of verifying the voltage is within start-up voltage range defined in section 4.1 of this specification. The 120 VAC UPS models shall check the voltage difference between neutral and ground terminals to determine if line and neutral are reversed or if ground is disconnected. A LED on the rear panel shall illuminate red for positive indication of a site wiring problem. For 230 VAC models, this feature is not incorporated due to reversible national plug systems Once the input AC power has been qualified and followed by the UPS being switched ON, the UPS shall perform start-up tests, consisting of an electronics and battery test, prior to enabling output power from the inverter. Should the UPS fail any start-up test, the output power shall not be enabled and fault signals (visual and audible) shall be enunciated. B. Automatic self diagnostic test: Auto-restart The UPS must qualify the input power source line voltage before auto-restarting. Auto-restart shall be defined as the restart of the UPS once input power has returned (and qualified) after the UPS has shutdown due to battery depletion. Once the input power has been qualified, the UPS shall perform auto-restart tests, consisting of an electronics and battery test, prior to enabling output power from the inverter. The auto-restart battery test shall just be a voltage check, to ensure the battery is present. Should the UPS fail any test, the output power shall not be enabled and fault signals (visual, audible, and remote via RS232) shall be enunciated.the auto-restart feature 9

10 shall be capable of being disabled by the operator through the serial (RS232) communications port or through the optional communications slot. When disabled the UPS shall not provide inverter output power until the main On/Off switch has been depressed The UPS shall recharge the batteries, once the utility power has been restored to parameters defined in section of this specification. The factory default shall have the auto-restart feature enabled. The auto-restart feature shall be capable of having a delay, determined by the operator and programmed through the serial (RS232) communications port or through the optional communications slot. This delay shall be defined in seconds and shall be the time period before output power will be made available after the UPS has been restarted. This feature shall only be functional when the auto-restart feature is enabled. C. Automatic self diagnostic test: Bi-weekly The UPS contains a counter which will initiate a battery test after 14 days (336 hrs) of continuous normal mode operation. The test duration shall be approximately 15 seconds. Should a failure of the battery occur, the UPS will immediately return to normal mode and fault signals (visual, audible, and remote via RS232) shall be enunciated. The 14 day timer shall be reset after a manual battery test, back-up mode operation or if the UPS is switched OFF. No audible or remote (via RS232/contact closures) indication of the battery test shall be enunciated during the duration of the automatic battery test. The automatic bi-weekly battery test shall be capable of being disabled by the operator through the serial (RS232) communications port or through the optional communications slot Manual Battery Test The alarm silence/manual battery test switch shall initiate a manual battery test only when input power is present and no alarm conditions are present. The test shall operate the same as the automatic bi-weekly test described in section C of this specification. Should the UPS batteries not be capable of supporting the connected load for the test duration, the UPS shall immediately return to normal operation, without loss of connected load and fault signals (visual, audible, and remote via RS232) shall be enunciated. No audible or remote (via RS232/contact closures) indication of the battery test shall be enunciated during the duration of the manual battery test. The test button shall require the operator to push for 0.5 seconds to initiate the battery test Internal Battery Valve regulated, lead acid cells shall be used as a stored-energy source for the specified UPS system. The battery shall be housed internal to the UPS cabinet, and sized to support the inverter at rated load, with ambient temperature 25 deg C (77 deg F), for a minimum of 5 minutes reserve time. The UPS units shall have the capability to allow the operator to replace the internal battery. The batteries shall be accessible from a door located behind the front Bezel on the Mini Tower units and the battery retaining plate located behind the Battery door in the front of the Rackmount unit. A tool, such as a Phillips (cross-head) screwdriver shall be required to open the battery door. The battery voltage once the battery is opened, shall be a SAFE voltage of 48 VDC or less as required by UL Standard 1778 and European EN Standards Output Distribution 120 VAC units Mini Tower Output distribution shall be integral to the UPS, located on the rear of the unit. The 700 VA unit shall contain four (4) NEMA 5-15R receptacles. The 1000 VA and 1400 VA units shall contain six (6) NEMA 5-15R receptacles. The 2200 VA unit shall contain (6) NEMA 5-15R receptacles and (2) 5-20R receptacles. 10

11 Rackmount Output distribution shall be integral to the UPS, located on the rear of the unit. The 700 VA unit shall contain four (6) NEMA 5-15R receptacles. The 1000 VA and 1400 VA units shall contain six (6) NEMA 5-15R receptacles. The 2200 VA unit shall contain (6) NEMA 5-15R receptacles and (2) 5-20R receptacles. 230 VAC units Mini Tower Output distribution shall be integral to the UPS, located on the rear of the unit. All 230 VAC units will contain (4) IEC A sockets, and the 2200 VA unit contains an additional IEC A. The 230 VAC units shall be supplied with two (2) output cords that are 6.0 feet (1.8 meters) in length. These cords shall contain IEC A type connectors, one male and one female, and shall comply to European standards. Rackmount Output distribution shall be integral to the UPS, located on the rear of the unit. All 230 VAC units will contain (4) IEC A sockets, and the 2200 VA unit contains an additional IEC A. The 230 VAC units shall be supplied with two (2) output cords that are 6.0 feet (1.8 meters) in length. These cords shall contain IEC A type connectors, one male and one female, and shall comply to European standards Communications The UPS shall contain a DB9F (9 pin female) connector on the rear panel to allow UPS status communications to a computer system. The DB9F shall contain photo couplers to signal on battery and low battery operational status. The UPS shall also be capable of receiving a signal from the connected host system to initiate a UPS shutdown. This signal shall be a + 5 V to +12 V (RS232 level) that must remain for > 0.75 second duration. Additionally, it shall also communicate via serial communications. Communications protocol shall be level 1 compliant; with the following exceptions: Items not supported: - Input amperes - Battery amperes - Seconds - Minutes - Hours - Day of Week - Date - Month - Year - Watts (output) - Temperature The pin out configuration of the DB9F connector shall be: Pin Assignment Description 1 Low Battery (Open Collector: +V) 2 UPS TxD 3 UPS RxD 4 Remote Shutdown (5-12V DC,1.0 ma max); on battery operation 5 Common 6 No connection 7 Low Battery (Open Emitter: -V) 8 Utility Fail (normally closed) 9 On battery (normally open) Maximum voltage and current on pins 1,7,8,9 shall be 80 VDC, 10.0 ma maximum. 11

12 2.2.8 Optional Communications The UPS shall contain one communication slot to allow the operator to field install optional communication cards. These optional cards shall allow the UPS to communicate via Ethernet SNMP, connected directly to the LAN. Once the SNMP card is installed, the serial communications shall be disabled in the DB9F connector; however the photo-coupler signals (on battery, and low battery) shall remain active. The communication port shall be designed to provide simple installation where an electrical connections are made via an 26 pin edge card connector. NOTE: These Guide Specifications comply with the format outlined by the Construction Specifications Institute per CSI MP-2-1 and CSI MP

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Sola/Hevi-Duty S3K Series Mini-Tower UPS Sola/Hevi-Duty S3K Series Mini-Tower UPS GUIDE SPECIFICATIONS 700VA to 1600VA 120V models Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical

More information

Liebert PowerSure PSI UPS

Liebert PowerSure PSI UPS Liebert UPS GUIDE SPECIFICATIONS 1000VA to 3000VA Single - Phase Uninterruptible Power Supply Systems 1.1 SUMMARY 1.0 GENERAL This specification defines the electrical and mechanical characteristics and

More information

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL 1.1 SUMMARY Liebert GXT3 8000 & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL This specification shall define the electrical and mechanical characteristics and requirements

More information

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL 1.1 SUMMARY Liebert GXT3 10000VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL This specification shall define the electrical and mechanical characteristics and requirements for a continuousduty,

More information

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System Illuminator Series CM GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System This description contains all the necessary functional and technical

More information

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL GXT4 5000 & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL 1.1 SUMMARY This specification shall define the electrical and mechanical characteristics and requirements for a continuousduty,

More information

Illuminator Series CR NEMA 3R

Illuminator Series CR NEMA 3R Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the

More information

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III 1. SCOPE A. The Central Lighting Inverter shall be a solid-state three phase system designed to provide

More information

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. The Defender Mini CLI specification describes a single phase, online, solid state Lighting

More information

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

USER MANUAL. Power GUARD UPS. Uninterruptible Power System USER MANUAL Power GUARD UPS Uninterruptible Power System IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Power GUARD that should be followed during

More information

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.1 SUMMARY Liebert GXT4 8000 & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL This specification shall define the electrical and mechanical characteristics and requirements

More information

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state

More information

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible

More information

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential power problems (spikes, surges

More information

Liebert PSI XR 1000/1500/2200/3000, 120VAC. User Manual

Liebert PSI XR 1000/1500/2200/3000, 120VAC. User Manual Liebert PSI XR 1000/1500/2200/3000, 120VAC User Manual Technical Support Site If you encounter any installation or operational issues with your product, check the pertinent section of this manual to see

More information

Liebert GXT & 6000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

Liebert GXT & 6000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL 1.1 SUMMARY Liebert GXT4 5000 & 6000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL This specification shall define the electrical and mechanical characteristics and requirements

More information

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 3 Harsh Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Lighting

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems 3 Uninterruptible Power Systems S4K2U and S4K2U-5 Industrial On-Line UPS The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential

More information

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL CSI 263353.01EDR Static Uninterruptible Power Supply Systems Endeavor Series MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.1 SUMMARY

More information

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply APC Smart-UPS GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality of a continuous

More information

Liebert PowerSure PSI

Liebert PowerSure PSI Power Protection for Business Critical Continuity Liebert PowerSure PSI User Manual 1000-3000VA, 60 Hz, 120V TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................................1

More information

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible

More information

AC Power For Business-Critical Continuity. Liebert PSI XR. User Manual 1000/1500/2200/3000VA, 50/60Hz, 230VAC

AC Power For Business-Critical Continuity. Liebert PSI XR. User Manual 1000/1500/2200/3000VA, 50/60Hz, 230VAC AC Power For Business-Critical Continuity Liebert PSI XR User Manual 1000/1500/2200/3000VA, 50/60Hz, 230VAC TABLE OF CONTENTS 1.0 INTRODUCTION..........................................................4

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible

More information

Product Specifications

Product Specifications Product Specifications Guide Specification for FirstLine 10Kva, 15Kva, and 20Kva Three-Phase, On-Line Uninterruptible Power Supply 4-15-10 301 Gaddis blvd, Dayton, OH 45403, USA Telephone: (866) 261-2257,

More information

MINUTEMAN POWER TECHNOLOGIES Endeavor LCD Series Product Specifications 1000VA 3000VA Single-phase Uninterruptible Power Supply 1.

MINUTEMAN POWER TECHNOLOGIES Endeavor LCD Series Product Specifications 1000VA 3000VA Single-phase Uninterruptible Power Supply 1. CSI263353.03ED Static Uninterruptible Power Supply Systems Endeavor LCD Series MINUTEMAN POWER TECHNOLOGIES Endeavor LCD Series Product Specifications 1000VA 3000VA Single-phase Uninterruptible Power Supply

More information

POWER kva

POWER kva TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power

More information

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality GE Digital Energy Power Quality Technical data sheet Digital Energy Uninterruptible Power Supply VH700-1000 - 1500 2000 UL A product by: GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino

More information

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL U P S Uninterruptible Power System Line-Interactive Network UPS 800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

More information

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA Illuminator Series LV Single Phase ILLUMINATOR SERIES LV The Illuminator Series LV is a 175VA-750VA fast transfer Emergency Lighting

More information

UPStation GXT. 6 & 10 kva 208V & 240V. USER MANUAL English

UPStation GXT. 6 & 10 kva 208V & 240V. USER MANUAL English UPStation GXT 6 & 10 kva 208V & 240V USER MANUAL English IMPORTANT SAFETY INSTRUCTIONS WARNING: Opening or removing the cover may expose you to lethal voltages within this unit even when it is apparently

More information

POWER kva

POWER kva +44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw

More information

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4 USER S MANUAL PowerWalker VFI 1000 / 3000VA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION......... 2 3. SYSTEM DESCRIPTION......... 4 4. CABLE CONNECTION......... 7 5. OPERATION...... 8 6. TROUBLE

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

Installation and Operation Back-UPS BX550CI-CN

Installation and Operation Back-UPS BX550CI-CN Installation and Operation Back-UPS BX550CI-CN Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there

More information

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model UniStar III Series 1, 2, & 3kVA Tower Model On-line, Single-phase UPS System The UniStar III is a sophisticated yet affordable single phase, double conversion UPS system. It offers on-line technology and

More information

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL Important Safety Information Before installing UPS EN-1000/ EN-2000, please read the operating instructions carefully. Special attention

More information

Uninterruptible Power Systems

Uninterruptible Power Systems Sola 4K Industrial On-Line Uninterruptible Power Systems (UPS) The true on-line (double conversion) protection offered by the S4K Industrial UPS series eliminates a wider range of potential power problems

More information

GUIDE SPECIFICATIONS 15-45kVA and 15-90kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

GUIDE SPECIFICATIONS 15-45kVA and 15-90kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL 1.1 SUMMARY Liebert APM UPS GUIDE SPECIFICATIONS 15-45kVA and 15-90kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL Liebert APM UPS, 15-45 kva and 15-90 kva Scalable This specification

More information

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation and Operation Manual Back-UPS BX1100CI-CN Installation and Operation Manual Back-UPS BX1100CI-CN Safety and General Information This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or

More information

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems EON Model EL3 Three Phase Centralized Emergency Lighting Inverter General Specification 10KW 33KW Systems 1.0 GENERAL This specification defines the electrical and mechanical characteristics and requirements

More information

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Technical Specifications Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER Sentinel PRO CONTENTS 1. GENERAL DESCRIPTION... 2 1.1. Main features of the UPS unit... 3 1.2. Standard Versions...

More information

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC) TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)

More information

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy GE Digital Energy Technical data sheet Uninterruptible Power Supply LP11 924 Series 6 & 10 kva gimagination at work GE T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www..com General data Topology VFI,

More information

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems EON Model EL3 Three Phase Centralized Emergency Lighting Inverter General Specification 40KW 55KW Systems 1.0 GENERAL This specification defines the electrical and mechanical characteristics and requirements

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual SEI 150/48-SEL-XXX DC-UPS SEI Incorporated 5115 Pegasus Court, Suite Q Frederick, Md 21704 Phone 301-694-9601 Fax 301-694-9608 Email Info@seipower.com Web http://www.seipower.com

More information

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out) TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies S5KC Modular Series On-ine Uninterruptible Power Systems (UPS) The S5KC Modular UPS is scalable from 5 to 20 kva, offering many flexible options by adding a few standard modules. Designed to be fully configured,

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (doubleconversion) UPS system available in 700-3000VA, 120V and 230V. On-Line design means zero transfer time

More information

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4 USER S MANUAL ON-LINE 1K/2K/3KVA CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. UPS OPERATION...... 12 6. TROUBLE

More information

Uninterruptible Power Systems

Uninterruptible Power Systems Sola S4K2U Industrial On-Line Uninterruptible Power Systems (UPS) The true on-line (double conversion) protection offered by the S4K2U Industrial UPS series eliminates a wider range of potential power

More information

2 Uninterruptible Power Systems

2 Uninterruptible Power Systems 2 Uninterruptible Power Systems S4K2U-C and S4K2U-5C Industrial On-Line UPS The new SolaHD S4KC is a single-phase, on-line (doubleconversion) UPS system available in 700-3000VA, 120V and 230V. On-Line

More information

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9 MODEL NUMBER: AL-84111 Specifications OUTPUT Output Volt Amp Capacity (VA) 2200 Output kva Capacity

More information

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out) TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS AVR Protection

More information

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems: TECHNICAL GUIDE SPECIFICATIONS Power-Lite Single Phase, (200 to 490 Watts) UL924 Central Lighting Inverter 1. SCOPE The Emergency Lighting Power System shall be a solid-state single phase unit designed

More information

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,

More information

AT EVO SERIES BATTERY CHARGER

AT EVO SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation

More information

Series VA 230V. USER MANUAL English

Series VA 230V. USER MANUAL English Series 4000 700-3000 VA 230V USER MANUAL English IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product yourself except to replace the battery. Opening or removing the cover may

More information

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality

More information

Technical data sheets

Technical data sheets GE Consumer & Industrial Power Protection Technical data sheets Digital Energy Uninterruptible Power Supply LP 11 Series / 3 5 6 8 10 kva A product by: GE Consumer & Industrial SA General Electric Company

More information

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Match 19 GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19 UPS. Match 19" Uninterruptible Power Supply 700-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency AVR Protection Compact

More information

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems Sola 4K Industrial On-Line Uninterruptible Power Systems (UPS) The true on-line (double conversion) protection offered by the S4K Industrial UPS series eliminates a wider range of potential power problems

More information

ATevo SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative

More information

U N I T Y / Three-Phase Uninterruptible Power Systems UT380 and UT Hz

U N I T Y / Three-Phase Uninterruptible Power Systems UT380 and UT Hz U N I T Y / I TM Three-Phase Uninterruptible Power Systems UT380 and UT3100 60 Hz Guide Specifications LTQ-1002B 12/95 In this document, explanatory notes are set in italics. Each note provides additional

More information

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 TOSHIBA 4400 15/20/25/30/50/80kVA Internal Transformers GUIDE SPECIFICATION

More information

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System POWER TROLLEY 8 Model: SINE 1548 Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System Version 07 CONTENTS Page 1. INTRODUCTION... 1 2. USING THE POWER TROLLEY.... 2 3. BATTERY BACKUP

More information

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA Important Safety Information Before installing UPS Endure 500VA/750VA/1000VA/2000VA, please read the operating instructions carefully.

More information

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Special Specification 6058 Battery Back-Up System for Signal Cabinets Special Specification Battery Back-Up System for Signal Cabinets 1. DESCRIPTION 2. DEFINITIONS Install a Battery Back-Up System (BBU System) for traffic signals that will provide reliable emergency power

More information

Technical Specification SENTINEL PRO

Technical Specification SENTINEL PRO Technical Specification SENTINEL PRO Contents 1 GENERAL DESCRIPTION... 3 1.1 Main features of the UPS unit... 4 1.2 Standard Versions... 4 1.3 ER Versions for extended autonomy... 4 2 SENTINEL PRO SERIES

More information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION... CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. INVERTER OPERATION... 11 6. TROUBLE SHOOTING GUIDE....... 16 7.

More information

EFFEKTA Power Supplies

EFFEKTA Power Supplies EFFEKTA GENERAL INFORMATION UPS topology ON LINE - Double Conversion Classification VFI-SS-111 in accordance with IEC 62040-3 Nominal output power (Cos Ø 0,9) - kva 10 15 20 30 40 Nominal output power

More information

TOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

TOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 TOSHIBA 4400 15/20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE

More information

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,

More information

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC Manufacturer s declaration in accordance with 8- Frame Model catalogue reference 93PS-XX(20)-YY- 93PS-XX(40)-YY- Number of power modules (UPM) 1 1 or 2 Number of internal batteries 0 to 2 x 32 blocks 0

More information

EVO AT SERIES BATTERY CHARGER

EVO AT SERIES BATTERY CHARGER EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T PATENT PENDING hindlepowerinc.com 610-330-9000 Evo AT Series battery charger designed with YOU in mind. Evo AT Series battery charger

More information

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER Evo Series battery charger designed with YOU in mind. Evo Series battery charger is a next generation SCR-based utility battery charger. This evolutionary

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies SDU Series, Direct Current Uninterruptible Power Supply (DC UPS) System The SDU DIN Rail DC UPS is an advanced uninterruptible power system that combines an industry leading design with a wide operational

More information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9 USER MANUAL 1 CONTENTS 1. INTRODUCTION... 1 2. SAFTY INSTRUCTION... 3 3. CABLE CONNECTION... 4 4. SYSTEM DESCRIPTION... 5 5. OPERATION... 9 6. TROUBLE SHOOTING GUIDE... 25 7. OPERATION MODES..... 27 8.

More information

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out) TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power

More information

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

User Manual Back-UPS BX650CI-MS 230 Vac with AVR User Manual Back-UPS BX650CI-MS 230 Vac with AVR Overview Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Read the Safety

More information

General Precautions. Personnel Precautions

General Precautions. Personnel Precautions USER MANUAL General Precautions 1. Before using Inverex, read all instructions and cautionary markings on : (1) Inverex (2) the batteries (3) this manual 2. CAUTION --To reduce risk of injury, charge only

More information

Uninterruptible Power Systems

Uninterruptible Power Systems S4K4U 6 kva and S4K6U 10 kva Industrial On-Line UPS The S4K4U6000 and the S4K6U10000 Industrial UPS Series are the first true On-Line industrial UPS that provide flexible output voltage, an integrated

More information

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option MODEL NUMBER: SUT20K Highlights On-line double-conversion topology, VFI operation

More information

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software APC's Back-UPS ES series is now "greener" than ever. The ES 350 utilizes an ultra-efficient design that consumes less power

More information

Up to 98% efficient under full load Similar runtimes to the previous 3u model

Up to 98% efficient under full load Similar runtimes to the previous 3u model New Model replacing the PS6003rm3uXL Up to 98% efficient under full load Similar runtimes to the previous 3u model @ 1,000 800 600 400 200 : ' 100 e 80 " E 60 ~ " "' 40 20 10 8 500 1,000 1,500 2,000 2,500

More information

1. INTRODUCTION. Features:

1. INTRODUCTION. Features: 1. INTRODUCTION This series is a compact and fully pure sinewave line interactive UPS, and it designs for critical application and environment, such as desktops, servers, workstations, and other networking

More information

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA) Back-UPS 650 VA 230 V with AVR (BX650CI-ZA) Overview Do not install the unit in direct sunlight, in areas of excessive heat or humidity, or in contact with fluids ON/OFF button Battery connector Circuit

More information

SECTION DC POWER SUPPLY/BATTERY CHARGER

SECTION DC POWER SUPPLY/BATTERY CHARGER SECTION 26 33 05 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide the single-phase heavy-duty industrial battery charger and all accessories required, complete and operable, in accordance

More information

Marketing Management Team of Europe

Marketing Management Team of Europe Emerson Network Power Liebert NXe UPS GUIDE SPECIFICATIONS For a 10 to 20 kva (50 or 60Hz) Parallelable Digital Uninterruptible Power Supply (UPS) System - 1 - Contents 1.1 SUMMARY... 3 1.2 STANDARDS...

More information

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC User s Manual K01-C000304-02 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5

More information

Aurora Single Phase Emergency Lighting Inverters

Aurora Single Phase Emergency Lighting Inverters Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available

More information

Uninterruptible Power Supply

Uninterruptible Power Supply AC/DC Din Rail UPS System Single Phase Input, Single Phase Output Uninterruptible Power Supply 600VA UPS System AC/DC Din Rail Mount Line Interactive (PWM): 600VA User Manual M1201_Din_Rail_AC-DC_600VA_Manual

More information

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Power Inverter. User s Manual. Diamond Series CPD1200EILCD Power Inverter Diamond Series CPD1200EILCD User s Manual 2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5 2-2 Product Overview & Outlook..5 2-3 Power Requirements

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA U P S Uninterruptible Power System Line Interactive Network Protection Pure Sine Wave Output UPS Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY

More information