RM moveit. Instruction Manual. Notebus -IC. Notebus + Notebus (LAP16-17H IC) (LAP16-17H EPM) (LAP16-17H B)

Size: px
Start display at page:

Download "RM moveit. Instruction Manual. Notebus -IC. Notebus + Notebus (LAP16-17H IC) (LAP16-17H EPM) (LAP16-17H B)"

Transcription

1 RM moveit Instruction Manual Notebus Notebus + Notebus -IC (LAP16-17H B) (LAP16-17H EPM) (LAP16-17H IC)

2 RM moveit Instruction Manual The RM moveit (Bretford LAP16-17H) is specifically designed for the storage and recharging of laptops The RM moveit (Bretford LAP16-17H) can be supplied in 3 different versions: Basic (notebus), Electronic Power Management (notebus +) or Intelligent Charging (notebus -IC). The unique design then allows the trolley to be easily upgraded, promoting a truly future proof solution. This is achieved via the removable/replaceable power module which can be simply swapped out by the user, so as your schools requirements change the power module can be easily upgraded. All electronic components are housed in this easily removable module, meaning that in the unlikely event that something goes wrong the user can quickly and easily replace the power module, reducing down time. The power module is located at the rear of the unit and features a locking door to ensure only authorised access. To assemble/configure your new storage & recharging cabinet simply follow the steps for the relevant model you have purchased. notebus (LAP16-17H B) - see page 2 notebus + (LAP16-17H EPM) - see page 4 notebus-ic (LAP16-17H IC) - see page 6 Optional Upgrades Data Transfer: Only the notebus+ (LAP16-17H EPM) and the notebus-ic (LAP16-17H IC) can facilitate data transfer activities, featuring 19 rack mounting brackets; a built-in network lead; external ethernet socket; and power provisions for a network switch as standard. (Network switch not included) A Network Loom Kit is available as an optional upgrade with these models, which includes 2 x 8 network lead looms, all bound & pre-cut to the required lengths. (Network switch not included) The Network Loom Kit can be added, either at the time of initial purchase or by the user at a later date. If you ordered the Network Loom Kit at the same time as the cabinet, then the 2 network lead looms will be pre-fitted in the cabinet. Simply mount a network switch to the 19 rack mount and connect all the leads in to commence data transfer activities. (Network switch not included) - See page 8 for full details. FANS: Fans are required if you intend to use the unit s data transfer capabilities. To provide the increased ventilation and cooling needed. Fans can be added to all 3 models, either at time of initial purchase or by the user at a later date. If you ordered the optional fans at the same time as the cabinet, then the fans will have been pre-fitted at the factory. 1

3 RM moveit - Notebus The RM moveit - Notebus (Bretford LAP16-17H-B) unit features 16 switchable power sockets located in the rear of the unit and power pack shelves accessed through the side doors. The basic unit uses the laptop s own mains lead and power pack for charging. Ventilation: All vents MUST be kept clear at all times, no posters etc. covering the perforations. Also ensure there is a minimum of 50mm clearance between the back and sides of the cabinet to ensure good air flow. Fans: If fans are fitted: Whilst charging, if the temperature in the cabinet exceeds 30 the fans will automatically initiate. The fan guards MUST be kept clear at all times, including allowing a minimum of 75mm clearance between the back of the cabinet and the wall to ensure good air flow. The fans will continue to run until the temperature drops below 30. However, if the room has a high ambient temperature this may cause the fans to remain on. To assemble/configure your new charging trolley, simply follow the steps below... DO NOT CONNECT TO THE MAINS SUPPLY UNTIL STEPS 1-10 ARE COMPLETE Step 1: Step 1: In a clear floor area lay the cabinet on its back and make sure that the area is off limits to all people other than those engaged in fixing the castor plates. BRETFORD ADVISE THIS IS A MINUMUM TWO PERSON OPERATION The four hole castor plates need to be bolted to the underside of the cabinet using the bolts, spring washers and flat washers provided. A single flat washer is to be located between the castor plate and the cabinet base at the 4 threaded fixing points provided. Each of the fixing bolts (4 are required to securely mount a single castor plate) complete with a spring washer should then be passed through the location holes in the castor plate, the flat washer as previously described and finally locate into the fixing points. We recommend that the two locking castors are fitted to the front of the cabinet. Once located by hand all bolts should then be securely tightened using an appropriately sized spanner or socket. Once all 4 castors are fitted carefully return the cabinet to an upright position. It is important that all castor plates are fitted as described above and checked before using the cabinet. Step 2: Move to the rear of the cabinet, next to the mains socket and on/off switch you will see an M5 fastener. Take one of the plastic bumpers, a washer and an M5 screw provide (can be found in the box with the manual) and attach to the cabinet using a posidrive head screwdriver. Then take the second the plastic bumpers, a washer and an M5 screw provide and attach to the other M5 fastener located next to the CAT socket to the left. NOTE: Please ensure that the M5 screws are not over tightened when fixing the plastic bumpers to the trolley. 2

4 Step 3: Move to the rear of the unit, unlock and open the rear door to reveal 16 switchable plug sockets & 4 master switches. Ensure that the 4 master switches are in the OFF position. Step 4: Disconnect the laptop s mains lead from its power pack Step 5: Plug the laptop s mains lead plug into one of the plug sockets. Then feed the lead through the adjacent grommet hole to the power pack shelves. Repeat until all the mains leads are plugged in and leads fed through. Step 6: Move to one of the side access doors, unlock and open to reveal 8 power pack shelves Step 7: Take the laptop s mains lead, previously fed through & re-connect to the laptops power pack Step 9: Move to the front of the cabinet, unlock and open the front doors to reveal 8 horizontal laptop shelves. Select one of the connecting leads, previously fed through & plug it into the laptop. Step 11: Ensure that the cabinet s On/Off switch, located at the rear of the cabinet, is in the OFF position. Plug the cabinet s mains lead into the IEC socket above the On/Off switch. Step 13: Switch on the cabinets On/Off switch, located at the rear of the cabinet. The red LED light on the front of the cabinet will illuminate to show the unit is receiving power. Step 8: Place the laptop s power pack onto the power pack shelf and push the laptop s connecting lead through to the adjacent shelf. Repeat steps 6-7 until all power packs and leads are in place. Then repeat the same process with the 8 power pack shelves on the opposite side of the cabinet. Step 10: Place the laptop onto the shelf and repeat until all laptops are connected and in place - 2 laptops per shelf. Use the supplied cable ties to tidy any excess cable. Step 12: IMPORTANT When connecting to a 13amp mains supply socket, ensure the wall socket is a switched socket and is in the off position. Then plug the cabinet mains plug into the wall socket and switch on. 3

5 Step 14: Return to the power module at the rear of the cabinet and switch on each of the plug sockets. Then switch on the 4 master switches to the right hand side of the sockets individually. IMPORTANT: Failure to switch on the 4 master switches in sequence may result in the building circuits being tripped. Step 15: When charging is complete, switch off the cabinet s On/Off switch. Switch off the 4 master switches, disconnect and remove the laptops for use as required. RM moveit - Notebus+ The RM moveit notebus+ (Bretford LAP16-17H EPM) features a built-in Electronic Power Management system that regulates the power demand and prevents the schools circuits being tripped. The power module located at the rear of the unit features 16 built-in Y-leads, which connect the EPM power module directly into the laptops power pack. Dispensing with the laptops own 3pin plug and lead to reduce the amount of excess cable. Ventilation: All vents MUST be kept clear at all times, no posters etc. covering the perforations. Also ensure there is a minimum of 50mm clearance between the back and sides of the cabinet to ensure good air flow. Fans: If fans are fitted: Whilst charging, if the temperature in the cabinet exceeds 30 the fans will automatically initiate. The fan guards MUST be kept clear at all times, including allowing a minimum of 75mm clearance between the back of the cabinet and the wall to ensure good air flow. The fans will continue to run until the temperature drops below 30. However, if the room has a high ambient temperature this may cause the fans to remain on. To assemble/configure your new charging trolley, simply follow the steps below... DO NOT CONNECT TO THE MAINS SUPPLY UNTIL STEPS 1-8 ARE COMPLETE Step 1: Step 1: In a clear floor area lay the cabinet on its back and make sure that the area is off limits to all people other than those engaged in fixing the castor plates. BRETFORD ADVISE THIS IS A MINUMUM TWO PERSON OPERATION The four hole castor plates need to be bolted to the underside of the cabinet using the bolts, spring washers and flat washers provided. A single flat washer is to be located between the castor plate and the cabinet base at the 4 threaded fixing points provided. Each of the fixing bolts (4 are required to securely mount a single castor plate) complete with a spring washer should then be passed through the location holes in the castor plate, the flat washer as previously described and finally locate into the fixing points. We recommend that the two locking castors are fitted to the front of the cabinet. Once located by hand all bolts should then be securely tightened using an appropriately sized spanner or socket. Once all 4 castors are fitted carefully return the cabinet to an upright position. It is important that all castor plates are fitted as described above and checked before using the cabinet. 4

6 Step 2: Move to the rear of the cabinet, next to the mains socket and on/off switch you will see an M5 fastener. Take one of the plastic bumpers, a washer and an M5 screw provide (can be found in the box with the manual) and attach to the cabinet using a posidrive head screwdriver. Then take the second the plastic bumpers, a washer and an M5 screw provide and attach to the other M5 fastener located next to the CAT socket to the left. NOTE: Please ensure that the M5 screws are not over tightened when fixing the plastic bumpers to the trolley. Step 3: Move to one of the side access doors, unlock and open to reveal 8 power pack shelves & 8 Y-leads Step 4: Disconnect the laptop s mains lead from its power pack Step 5: Select the correct connection end on the Y-lead connector to plug into the laptop s power pack and connect. Step 7: Move to the front of the cabinet, unlock and open the front doors to reveal 8 horizontal laptop shelves. Select one of the connecting leads, previously fed through & plug it into the laptop. Step 6: Place the laptop s power pack onto the power pack shelf and push the laptop s connecting lead through to the adjacent shelf. Repeat steps 2-4 until all power packs and leads are in place. Then repeat the same process with the 8 power pack shelves & Y-leads on the opposite side of the cabinet. Step 8: Place the laptop onto the shelf and repeat until all laptops are connected and in place - 2 laptops per shelf. Use the supplied cable ties to tidy any excess cable. Step 10: IMPORTANT Connecting to a 13amp mains supply socket. Ensure the wall socket is a switched socket and is in the OFF position, then plug the cabinet mains plug into the wall socket and switch on. Step 12: A red LED light on the front of the unit will illuminate, indicating that the unit is receiving power. If the red LED light flashes refer to the frequently asked questions on page 9 Step 9: Ensure that the cabinet s On/Off switch, located at the rear of the cabinet, is in the off position. Plug the cabinet s mains lead into the IEC socket above the On/Off switch. Step 11: Switch on the cabinet s On/Off switch, located at the rear of the cabinet Step 13: When charging is complete, switch off the cabinet s On/Off switch. Disconnect and remove the laptops for use as required. 5

7 RM moveit Notebus-IC The RM moveit Notebus-IC (Bretford LAP16-17H IC), features an intelligent charging system that offers ultra safe, low voltage charging and will also prevent the school s circuits being tripped. The power module located at the rear of the unit, is configured for the specific laptops being used and is supplied with 16 built-in connecting leads, meaning no AC adaptors are required as the leads plug directly into the laptops. Ventilation: All vents MUST be kept clear at all times, no posters etc. covering the perforations. Also ensure there is a minimum of 50mm clearance between the back and sides of the cabinet to ensure good air flow. Fans: If fans are fitted: Whilst charging, if the temperature in the cabinet exceeds 30 the fans will automatically initiate. The fan guards MUST be kept clear at all times, including allowing a minimum of 75mm clearance between the back of the cabinet and the wall to ensure good air flow. The fans will continue to run until the temperature drops below 30. However, if the room has a high ambient temperature this may cause the fans to remain on. To assemble/configure your new charging trolley, simply follow the steps below... DO NOT CONNECT TO THE MAINS SUPPLY UNTIL STEPS 1-5 ARE COMPLETE Step 1: Step 1: In a clear floor area lay the cabinet on its back and make sure that the area is off limits to all people other than those engaged in fixing the castor plates. BRETFORD ADVISE THIS IS A MINUMUM TWO PERSON OPERATION The four hole castor plates need to be bolted to the underside of the cabinet using the bolts, spring washers and flat washers provided. A single flat washer is to be located between the castor plate and the cabinet base at the 4 threaded fixing points provided. Each of the fixing bolts (4 are required to securely mount a single castor plate) complete with a spring washer should then be passed through the location holes in the castor plate, the flat washer as previously described and finally locate into the fixing points. We recommend that the two locking castors are fitted to the front of the cabinet. Once located by hand all bolts should then be securely tightened using an appropriately sized spanner or socket. Once all 4 castors are fitted carefully return the cabinet to an upright position. It is important that all castor plates are fitted as described above and checked before using the cabinet. Step 2: Move to the rear of the cabinet, next to the mains socket and on/off switch you will see an M5 fastener. Take one of the plastic bumpers, a washer and an M5 screw provide (can be found in the box with the manual) and attach to the cabinet using a posidrive head screwdriver. Then take the second the plastic bumpers, a washer and an M5 screw provide and attach to the other M5 fastener located next to the CAT socket to the left. NOTE: Please ensure that the M5 screws are not over tightened when fixing the plastic bumpers to the trolley. 6

8 Step 3: Disconnect the laptop s charging lead and power pack. Store in a safe place. Step 4: Move to the front of the cabinet, unlock and open the front doors to reveal 8 horizontal laptop shelves. Select one of the built-in connecting leads & plug it into the laptop. Step 5: Place the laptop onto the shelf and repeat until all laptops are connected and in place 2 laptops per shelf. Step 7: IMPORTANT Connecting to a 13amp mains supply socket. Ensure the wall socket is a switched socket and is in the OFF position, then plug the cabinet mains plug into the wall socket and switch on. Step 9: A red LED light on the front of the unit will illuminate, indicating that the unit is receiving power. If the red LED light flashes, refer to the frequently asked questions on page 9. Step 6: Ensure that the cabinet s On/Off switch is in the off position. Plug the cabinet s mains lead into the IEC socket above the On/Off switch Step 8: Switch on the cabinet s On/Off switch, located at the rear of the cabinet. Step 10: When charging is complete, switch off the cabinet s On/Off switch. Disconnect and remove the laptops for use as required. 7

9 Additional Functions Using the accessory Power Board Using the accessory Power Board All units features a built-in additional 4-way power board located at the rear of the top shelf inside the unit. This additional power provision is ideal for use with wireless access points, printer or the multi-bay charger. Simply place the equipment on the top of the units and pass the power leads though the grommet hole to the power board below. IMPORTANT: The power board must not be used with the multi-bay charger whilst charging is in progress. Using a Wireless Access Point (WAP): All units comes with a built-in network lead and power provisions to facilitate the use of a wireless access point, plus an external ethernet socket for easy connection to a LAN point. The WAP is not provided. To use the unit with a WAP, simply follow the steps below... DISCONNECT THE UNIT FROM THE ELECTRICAL SUPPLY! Step 1: Ensure the unit s On/Off switch is in the OFF position. Then plug the WAP s mains plug into one of the power sockets on the accessory power board, located at the rear of the top shelf inside the unit Step 2: Feed the lead up through the grommet hole in the top of the unit and connect into the WAP unit Step 3: Feed the unit s built-in network lead through the grommet hole on the top of the unit and connect into the WAP unit Step 4: Connect a network lead into the ethernet socket located next to the ON/OFF switch at the rear of the unit. Then connect the other end of the network lead into a LAN point. Step 5: When not in use, disconnect the WAP and store on the top shelf inside the unit NOTE: Only a single built-in network cable and external ethernet socket are provided! 8

10 Undertaking Data Transfer Activities: The Network Loom Kit is available as an optional upgrade with the RM moveit notebus+ (LAP16-17H EPM) & notebus IC (LAP16-17H IC). The kit includes 2 x 8 network lead looms, all bound & pre-cut to the required lengths for easy to install. (The network switch is not included) To install the Network Lead Loom kit, simply follow the steps below DISCONNECT THE UNIT FROM THE ELECTRICAL SUPPLY! Step 1: Open the front doors of the unit to access the 19 rack mounting brackets located on the top left hand side of the cabinet. Then attach the network switch to the mounting brackets. Step 2: Plug the mains lead for the network switch into the accessory power board located to the right of the mounting brackets Step 3: Connect the internal network cable into the network switch Step 4: Take the network lead looms and connect the equal length ends into the network switch. Connect the loom labelled 1-8 into the left hand side of the switch and the loom labelled 9-16 into the right hand side of the switch*. Step 5: Feed the 1 st network lead loom, labelled 1-8, down the cable channel on the left hand side of the cabinet. Step 6: Pull the network lead labelled 1 through to the top storage shelf and then the lead labelled 2 through to the second shelf and so on until all 8 network leads are in place. This may be helped by opening the side access door. Step 7: Repeat steps 5 & 6 with the second loom down the right hand side cable channel. Pulling lead 9 through to the top shelf, followed by lead 10 to the second and so on. When all leads are in place then connect each network lead into the adjacent laptop Step 8: Connect a network lead into the ethernet socket located next to the ON/OFF switch on the rear of the unit. Then connect the other end of the network lead in to a LAN point. Your RM moveit is now networked and ready for use with Data Transfer Activities. *NOTE: If the Network Loom Kit is ordered at the time of initial purchase, then the 2 network lead looms will be pre-fitted in the cabinet.

11 Frequently Asked Questions Q. I have followed the configuration guidelines yet my unit does not appear to be charging? A. First complete the checks below... i. Check the unit is plugged into a mains supply wall socket and that the socket is switched on ii. Check that the mains socket is not faulty. Try connecting a known working piece of equipment e.g. radio iii. Check there is a fuse in the mains plug iv. Check the mains lead is correctly inserted into the cabinet. v. Check that the On-Off switch on the cabinet is switched on, 1 pressed down = on vi. Check that all other leads (Y-leads, connecting leads etc.) are correctly inserted into the cabinet and/or the laptops If the unit still isn t charging contact your supplier or Bretford directly. Q. Some but not all of my laptops are charging? A. i. A fuse in the power module may have blown The power module located in the rear of the trolley features 5 LED lights above 5 fuse compartments. If a fuse has blown, the corresponding LED indicator light will be illuminated RED. Remove the fuse and replace with a 10a fuse. ii. If no fuse fail indicators are lit, yet your laptops are not charging first check that the laptops are charging correctly when plugged directly into a known working mains wall socket If NO then see your laptop s own handbook or contact your laptop supplier. If YES contact your supplier or Bretford directly Q. The red light on the front of the unit has come on? A. This means that the unit is receiving power and your laptops should be charging correctly Q. The red light on the front of the unit is flashing? A. A fault may have developed, check the fuses. The power module located at the rear of the trolley features 5 LED lights above 5 fuse compartments. If a fuse has blown, the corresponding LED indicator light will be illuminated RED. Remove the fuse and replace with a 10a fuse. If no fuses have blown contact your supplier or Bretford Manufacturing directly. Q. The unit is blowing the building circuits? A. The RM moveit notebus+ & RM moveit notebus-ic Charging models incorporate a power management system that should prevent this from happening. If you have one of these models contact your supplier or Bretford directly. If you have the RM moveit notebus, this unit features 4 master switches on the power module. You must turn each of these on in turn. This limits the current demand surge and will prevent your school s building circuits being tripped. Q. The mains lead is damaged! A. DO NOT CONTINUE TO USE! Disconnect the mains lead from the wall socket and discard in compliance with the WEEE directive. Contact your supplier or Bretford for a replacement part Q. Can I use the unit to charge other items? A. This unit is designed for the storage and recharging of laptops only and we do not advise you use this unit for recharging any other devices 10

12 With the RM moveit How to claim Online Go to Scroll to the bottom of the page and click on the link to the online claim form Once complete submit the form and the claim process will begin. By post Complete the paper claim form which can be requested by calling You can also download it from the RM Insurance webpage (downloads section). Theft claims Make sure any thefts are reported to the police and make a note of the crime reference number as this will be required when making a claim. If you can t find your policy number All schools have access to the My Account feature through rm.com, which allows schools to see their orders, contracts, leases, etc. This feature also allows you to see details of the insurance purchased through RM. By clicking on the policy number you can see the order it relates to and the serial numbers of the insured machines. I need help with my claim RM Insurance operates a dedicated help line for questions on RM insurance. RM Insurance, claims helpline

13 Safety and Security Guidance This unit is designed for storage and re-charging of laptops ONLY To avoid damage, please ensure that the laptops are inserted and removed by a competent adult All vents and fan guards MUST be kept clear at all times, including allowing a minimum of 50mm clearance (75mm for fan vents) between the back and sides of the cabinet to ensure good air flow This unit should be used with a switched wall socket ONLY IMPORTANT: Ensure the wall socket is in the OFF position before connecting and removing the mains 13amp plug from the wall or cabinet For maximum security, the unit should be returned to a secure, alarmed area The mains lead should be disconnected and wound around the handles or stowed on top of the unit before moving To move the unit PUSH using the handles, DO NOT PULL As with all mobile products the unit should be manoeuvred with care, especially on inclines, by an competent adult The mains lead should be checked regularly to ensure there is no damage to the plug, lead or connector. In the event of damage do not continue to use! Discard the mains lead in compliance with the WEEE directive and contact your supplier or Bretford for a replacement part The unit is of an earthed construction and must only be connected to an earthed supply Total current must NOT exceed 13A, only use 13A fuse in mains plug No single item of ICT equipment used with the unit should have a rated current consumption exceeding 5A All individual ICT chargers used in this cabinet should be fused/protected at 5A Compliance/Warranty The unit is independently tested & certified to BS EN :2002/A2:2006 ensuring the highest levels of electrical/build safety and complies with the HSE October 2009 Manufacturing Guidelines upon electrical safety. The unit is of an all steel construction and feature a 12 year guarantee, (1 year on electrics). Subject to correct use, fair wear and tear. WEEE Directive When the unit becomes redundant, it must be disposed of in compliance with the WEEE Directive Contact your supplier or Bretford in the first instance. Bretford Manufacturing Ltd WEEE 2002:96EC 2 Etongate, 110 Windsor Road, Slough, Berkshire, SL1 2JA Tel: +44 (0) Fax: +44 (0) sales@bretforduk.com Web: Designed and manufactured in the UK by Bretford Manufacturing UK Ltd. 11

SimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0

SimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0 SimplePAT Battery Powered Portable Appliance Tester User Manual Issue 1.0 CONTENTS SAFETY 4 GETTING STARTED 5 INTRODUCTION 6 FEATURES 7 PLANNING THE TESTS Determining the Class of construction 9 Type

More information

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries. 1 Elmdene International Ltd Tel: +44 (0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44 (0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk STANDBY 220V AC POWER SYSTEM IDEAL

More information

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Melody 1 Platform Lift

Melody 1 Platform Lift USER MANUAL Melody 1 Platform Lift Original instructions CONTENTS PAGE Introduction 4 Description 4 General Do s and Don ts 6 Controls 7 Operating the Lift 8 Emergency Procedures 9 Platform Gate Lock

More information

PSU1 Power Supply Unit

PSU1 Power Supply Unit OM2443 PSU1 Power Supply Unit Distributed By: GMW Associates 955 Industrial Road, San Carlos, CA, 94070 USA PHONE: +1 650-802-8292 FAX: +1 650-802-8298 EMAIL: sales@gmw.com WEB: www.gmw.com Table of Contents

More information

The Powermatic User Guide Test Sieve Shaker

The Powermatic User Guide Test Sieve Shaker The Powermatic User Guide Test Sieve Shaker ISSUE 04-02 Contents Description Page 1 Setting Up: 2-8 Unpacking 2 Assembly 3-4 Levelling 4 Electrical Connections 5 Sieve Stacking 6-8 Operating Instructions

More information

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains Eazipole Cordless Installation & Set Up Instructions Electric Blinds & Curtains Pole Installation - Deciding The Best Position Points to consider when planning the installation of your pole It may be easiest

More information

PURE SINE WAVE DC TO AC POWER INVERTER

PURE SINE WAVE DC TO AC POWER INVERTER PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

EC400 Power Control System

EC400 Power Control System 1 Introduction This section of the handbook will guide you through the operation of the electrical system. Further technical details are contained in section 3 or in the supporting technical manual available

More information

HD18F2M1.

HD18F2M1. HD18F2M1 www.blackanddecker.com 3 2 1 5 A 4 5 B 4 7 10 9 C 4 6 D 4 8 1 11 12 E 2 F 3 2 G H 13 I 14 13 14 K 3 J 3 L M 16 15 4 Intended use Your Black & Decker hand held vacuum cleaner has been designed

More information

24V 3A EN54 Ancillary Power Supply

24V 3A EN54 Ancillary Power Supply 24V 3A EN54 Ancillary Power Supply Normal supply - green light on Fault condition - call Engineer Control relay - activated 3A Power Supply C-TEC Manufactured in England by C-Tec EN 54-4 : 1997 INSTALLATION

More information

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains Eazidraw Cordless Installation & Set Up Instructions Electric Blinds & Curtains Features Quiet, DC battery motor with low power consumption. Rechargeable battery with up to 500 uses between charges Fully

More information

V1606 3U RACK ENCLOSURE

V1606 3U RACK ENCLOSURE V1606 3U RACK ENCLOSURE Installation and Operation Pro-Bel Ltd Issue: 5.0 Date: October 07 Pro-Bel Ltd Danehill Lower Earley Reading Berks, RG6 4PB ENGLAND Web: www.pro-bel.com HU-V1606 1 data transceiver

More information

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts V2. Overview. HP Managed and Unmanaged V2 Notebook Charging Carts

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts V2. Overview. HP Managed and Unmanaged V2 Notebook Charging Carts Overview V2 Notebook Charging Carts Models HP 20 New! New! HP 30 New! New! T9E84AA T9E83AA T9E86AA T9E85AA Introduction Designed to securely store and charge notebook PCs-from tablets and minis to notebooks

More information

GENERAL INFORMATION. INSTRUCTIONS FOR 500A Lithium Jump Starter

GENERAL INFORMATION. INSTRUCTIONS FOR 500A Lithium Jump Starter INSTRUCTIONS FOR 500A Lithium Jump Starter Stock No.15067 Part No.LJS136 IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT. GENERAL INFORMATION These

More information

Model Number: CM-046. QUATTRO Handset Installation guide and user information. Ref: CM-046 UK-Rev.C.

Model Number: CM-046. QUATTRO Handset Installation guide and user information. Ref: CM-046 UK-Rev.C. Model Number: CM-046 QUATTRO Handset Installation guide and user information UK Ref: CM-046 UK-Rev.C. Table of Contents Package Contents (Parts List) Page 2 Introduction Page 4 Installation Safety Guidelines

More information

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No

More information

SSPF SO73-SO84A SSCA. Electric orbital sanders with dust extraction OPERATING AND MAINTENANCE INSTRUCTIONS

SSPF SO73-SO84A SSCA. Electric orbital sanders with dust extraction OPERATING AND MAINTENANCE INSTRUCTIONS SSPF SO73-SO84A SSCA Electric orbital sanders with dust extraction OPERATING AND MAINTENANCE INSTRUCTIONS 1 SPECIFICATIONS TYPE SSPF SO73 SO84A SSCA ELECTRIC SHOCK PROTECTION CLASS II II II II RATED SUPPLY

More information

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of Packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

TRAVEL-PAK BW TRAVEL-PAK INSTRUCTIONS BWL-0375/ Old Road Clacton on Sea Essex CO15 3RH UK

TRAVEL-PAK BW TRAVEL-PAK INSTRUCTIONS BWL-0375/ Old Road Clacton on Sea Essex CO15 3RH UK TRAVEL-PAK BW-760 55 Old Road Clacton on Sea Essex CO15 RH UK Tel: +44 (0)155 4807 Fax: +44 (0)155 464 GUIDE TRAVEL-PAK INSTRUCTIONS BWL-075/1 USER Table of Contents Specifications Description Page Introduction

More information

M2TECH PALMER POWER STATION LOW NOISE BATTERY POWER SUPPLY/CHARGER USER MANUAL

M2TECH PALMER POWER STATION LOW NOISE BATTERY POWER SUPPLY/CHARGER USER MANUAL M2TECH PALMER POWER STATION USER MANUAL REV. PRB 12/2011 Warning! Changes or modifications not authorized by the manufacturer can invalidate the compliance to CE regulations and cause the unit to be no

More information

EC200 ELECTRONIC CONTROL SYSTEM

EC200 ELECTRONIC CONTROL SYSTEM 1 INTRODUCING THE EC200 ELECTRONIC CONTROL SYSTEM With the use of new technology and an innovative approach to user interfacing, the EC200 Power Control System provides a complete control solution for

More information

Single Phase Electronic Speed Controllers

Single Phase Electronic Speed Controllers Single Phase Electronic Speed Controllers Installation and Wiring Instructions Stock Ref. N 10303103A 3A SPEED CONTROLLER ELECTRONIC 1PH 10303106A 6A SPEED CONTROLLER ELECTRONIC 1PH Rating: 220-240V ~

More information

Operators Guide: RoboSign Stop/Go Traffic Control System

Operators Guide: RoboSign Stop/Go Traffic Control System Operators Guide: RoboSign Stop/Go Traffic Control System RoboSign Remote controlled Stop/Go temporary traffic control system Operators Guide NZTA Conditions - Automated Stop/Go Traffic Control System NZTA

More information

The Power of Reliability INSTRUCTION MANUAL

The Power of Reliability INSTRUCTION MANUAL The Power of Reliability INSTRUCTION MANUAL SAFETY & WARNINGS Read this manual carefully and understand all Warnings and Cautions before connections are made to the Inverter. If unsure about any aspects

More information

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System POWER TROLLEY 8 Model: SINE 1548 Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System Version 07 CONTENTS Page 1. INTRODUCTION... 1 2. USING THE POWER TROLLEY.... 2 3. BATTERY BACKUP

More information

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W Instruction Manual Introduction The AIMS Power 5000 Watt series inverters are the most advanced line of mobile DC to AC power

More information

ADN-W L 10. Battery Charger. Instruction manual

ADN-W L 10. Battery Charger. Instruction manual ADN-W L 0 Battery Charger Instruction manual Contents Contents For your safety... The ADN-W L 0 charger... Package contents... Product overview ADN-W L 0... Preparing the ADN-W L 0 for operation... Setting

More information

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents The EFL 2000/1 & 2 User Guide Test Sieve Shaker ISSUE 04-02 Contents Description Page 1 Setting Up: 2-8 Unpacking 2 Assembly 3 Clamping Assembly 4 Electrical Connections 5 Sieve Stacking 6 8 Operating

More information

Solus Instruction Manual

Solus Instruction Manual Multi award winning power management systems Solus Instruction Manual Contents General section A. Introduction The company A.1 The principles A.1 The execution A.1 B. The product Overview B.2 Features

More information

1 Plug one extender near your router 2 Plug one extender near your device 3 Connect your device

1 Plug one extender near your router 2 Plug one extender near your device 3 Connect your device User Guide 1 Plug one extender near your router 2 Plug one extender near your device 3 Connect your device 500 Kit Follow the steps in this guide to set up your kit. If you need some help, see the Frequently

More information

LT Charging Cart for Laptops

LT Charging Cart for Laptops Built with Anthro-DNA LT Charging Cart for Laptops Owners Manual This unit has been tested to Underwriters Laboratories U.S. and Canadian (Bi-National) Standard for Safety of Informational Technology Equipment,

More information

RESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK PARTS DESCRIPTION

RESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK PARTS DESCRIPTION RESTWELL RISE & RECLINE ARMCHAIRS OWNER S HANDBOOK CONTENTS 1. Introduction 2. Parts Description 3. Personal Safety 4. Installation Instructions 5. Backrest Removal 6. Operating Instructions and Guidelines

More information

Car Battery Charger Instructions for Use

Car Battery Charger Instructions for Use BATTERY CHARGER 12Volt 4Amp FOR INDOOR USE ONLY Power Details: Input: 230-240Vac; 50Hz; 52W Output: 12V DC; 2.8A Maximum Charge Rate: 4A RMS Read these instructions before operating this car battery charger

More information

CARM INTERNATIONAL TOWING MODULES

CARM INTERNATIONAL TOWING MODULES CARM INTERNATIONAL TOWING MODULES (TA100/200 Instructions Revision = 1) Each Towing Module (if ordered with Loom Pack) is shipped with: A/ These instructions B/ 1 x Towing Control Module C/ 1 x high current

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

home ELITE CURVE CUSTOM CURVED RAIL STAIRLIFT Operator s Manual Keep this manual in a safe and readily accessible place for future reference.

home ELITE CURVE CUSTOM CURVED RAIL STAIRLIFT Operator s Manual Keep this manual in a safe and readily accessible place for future reference. home ELITE CURVE CUSTOM CURVED RAIL STAIRLIFT Operator s Manual Keep this manual in a safe and readily accessible place for future reference. REV. 23 January 2015 PRODUCT REGISTRATION FORM home Product

More information

EC400 / EC450 series Power Control System

EC400 / EC450 series Power Control System 1 Introduction This section of the handbook will guide you through the operation of the electrical system. Further technical details are contained in section 3 or in the supporting dealer technical manual

More information

CONTENTS. User Safety 2 Introduction and CX440 Accessories 3 CX440 Diagram 4 CX440 Keypad and Remote Control 5 Operating Instructions 6

CONTENTS. User Safety 2 Introduction and CX440 Accessories 3 CX440 Diagram 4 CX440 Keypad and Remote Control 5 Operating Instructions 6 CONTENTS User Safety 2 Introduction and CX440 Accessories 3 CX440 Diagram 4 CX440 Keypad and Remote Control 5 Operating Instructions 6 Batteries 6 Power and Horizontal Lines 7 Vertical Lines 8 Pulse (Outdoor)

More information

KENSUN HID AUTOMOTIVE HEAD LAMP CONVERSION KIT INSTALLATION MANUAL

KENSUN HID AUTOMOTIVE HEAD LAMP CONVERSION KIT INSTALLATION MANUAL 1 KENSUN HID AUTOMOTIVE HEAD LAMP CONVERSION KIT INSTALLATION MANUAL 2 CONTENTS A. Before Installing B. Installing the Bulbs C. Installing the Ballasts D. For Bi Xenon Only: Installing the Relay Harness

More information

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01 PrintPRO Universal Contents Overview 1 01 02 03 Overview of your extraction system (front) Overview of your extraction system (back) Overview of the Control Panel Safety Instructions 2 01 Important safety

More information

NCSA 20plus Service Manual

NCSA 20plus Service Manual Adam Equipment NCSA 20plus Service Manual (P.N. 7.00.6.6.0247- Revision A - August 2012) Adam Equipment Company 2012 1.0 CONTENTS 1.0 CONTENTS...1 1.1 KEY AND PANEL DESCRIPTION...2 2.0 OPERATION...3 2.1

More information

EMERGENCY VEHICLE BATTERY MANAGER PS2024

EMERGENCY VEHICLE BATTERY MANAGER PS2024 EMERGENCY VEHICLE BATTERY MANAGER PS2024 2 The PS2024 (Fig. 1) is designed as a on-vehicle battery charger / battery charge state monitor. While the vehicle is at its base or station, the charger is connected

More information

JUMP STARTER OPERATOR S MANUAL RA1900

JUMP STARTER OPERATOR S MANUAL RA1900 JUMP STARTER OPERATOR S MANUAL RA1900 SAVE THESE INSTRUCTIONS: This manual contains important safety and operating instructions for the RA1700 jump start. Read through this owner s manual carefully before

More information

Operators Guide: RoboSign Stop/Go Traffic Control System

Operators Guide: RoboSign Stop/Go Traffic Control System Operators Guide: RoboSign Stop/Go Traffic Control System RoboSign Remote controlled Stop/Go temporary traffic control system Operators Guide Table of Contents Operators Guide: RoboSign Stop/Go Traffic

More information

GL1200T Cut & Seal. (GL1200 Seal only)

GL1200T Cut & Seal. (GL1200 Seal only) GL INSTRUMENTS & Operating Instructions Safe Seal Cut & Seal Welder for Filter Sacks GL1200T Cut & Seal (GL1200 Seal only) For industrial use only Important Safety & Operating Instructions Please read

More information

3. Operating instructions: Minor 200

3. Operating instructions: Minor 200 1. Technical specifications 3. Operating instructions: Minor 200 Copyright 2015 by Endecotts Ltd. 13 1. Setting up Technical specifications SIEVE SHAKER MODEL: Minor 200 General Information The Minor 200

More information

Battery Power Inverters

Battery Power Inverters Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.4 Important Safety Instructions Please save these instructions.

More information

REMOTE CARAVAN MOVER Installation guide and user information. e-go /10/01/rev 3

REMOTE CARAVAN MOVER Installation guide and user information. e-go /10/01/rev 3 REMOTE CARAVAN MOVER Installation guide and user information Contents 1 1 Introduction 3 Parts List 4 Safety Guidelines 4 Technical Specifications 5 Fitting Guidelines (chassis adapters etc.) 6 Fitting

More information

Folding Scooter. User Manual

Folding Scooter. User Manual Folding Scooter User Manual CONTENTS 1. Safety Instructions 2. Electromagnetic Interference (EMI) 3. Transporting the Scooter 4. Specification 5. Folding Out the Scooter 6. Folding Up the Scooter 7. Scooter

More information

Roller Door Operator

Roller Door Operator INSTALLATION INSTRUCTIONS AND OWNERS MANUAL Roller Door Operator IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY PRIOR TO COMMENCING THE INSTALLATION OF THE OPERATOR UNIT CAUTION This Automatic Opener

More information

LH16E - LH16EN Angle mini-polishers OPERATING AND MAINTENANCE INSTRUCTIONS

LH16E - LH16EN Angle mini-polishers OPERATING AND MAINTENANCE INSTRUCTIONS LH16E - LH16EN Angle mini-polishers OPERATING AND MAINTENANCE INSTRUCTIONS 1 SPECIFICATIONS TYPE LH16E/LH16EN ELECTRIC SHOCK PROTECTION CLASS II RATED SUPPLY VOLTAGE 230V - 50Hz RATED CURRENT INPUT 4.1A

More information

instructions for roadstart units

instructions for roadstart units instructions for roadstart units model no: RS1.V5, RS102.V4, RS103.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,

More information

REMOTE CONTROLLED CENTRAL LOCKING SYSTEM. INCLUDES 4 DOOR ACTUATORS. Owner s Operation Manual

REMOTE CONTROLLED CENTRAL LOCKING SYSTEM. INCLUDES 4 DOOR ACTUATORS. Owner s Operation Manual Model number: MCL3400 REMOTE CONTROLLED CENTRAL LOCKING SYSTEM. INCLUDES 4 DOOR ACTUATORS Owner s Operation Manual For correct operation and warranty compliance, we recommend professional installation

More information

S D ST215 TAFFOR. ST215 Temperature Programmer User Handbook.

S D ST215 TAFFOR. ST215 Temperature Programmer User Handbook. TAFFOR S D ST215 ST215 Temperature Programmer User Handbook www.staffordinstruments.co.uk See separate handbook for Installation Instructions Issue: 1.000 ST215 Copyright User Handbook 2014 Stafford Instruments

More information

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart Overview Models HP 20-Notebook Charging Cart HP 30-Notebook Charging Cart HP 20-Notebook Managed Charging Cart HP 30-Notebook Managed Charging Cart QL488AA#ABA H4F31AA#ABA QL489AA#ABA QL490AA#ABA Introduction

More information

Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart Overview Models HP 20-Notebook Charging Cart HP 30-Notebook Charging Cart HP 20-Notebook Managed Charging Cart HP 30-Notebook Managed Charging Cart QL488AA#ABA H4F31AA#ABA QL489AA#ABA QL490AA#ABA Introduction

More information

The Stannah Stairiser SX User Manual

The Stannah Stairiser SX User Manual 9 NOTES The Stannah Stairiser SX User Manual Make sure you understand the contents of this booklet. Keep it handy for reference. Your Stairlift Number is: Please quote this number on any correspondence

More information

PS24/AC Volt AC 16 Amp

PS24/AC Volt AC 16 Amp ALTERNATING CURRENT POWER SUPPLY PS24/AC-6 24 Volt AC 6 Amp FEATURES: Mains Fail Relay Output and Indicator. Fuse blow indication and relay output. 6 fused outlets DESCRIPTION: SPECIFICATIONS: Inputs Voltage-

More information

DRAFT COPY, NOT FOR DISTRIBUTION

DRAFT COPY, NOT FOR DISTRIBUTION GENERAL INFORMATION This manual contains relevant information concerning the technical aspects of using the Mediheat MH900/12 Portable Fluid Bag Warmer, and should be read by all persons expected to operate

More information

CeraControl. Temperature Programmer User Handbook.

CeraControl. Temperature Programmer User Handbook. CeraControl Temperature Programmer User Handbook www.potterycrafts.co.uk See separate handbook for Installation Instructions Issue: 1.01 CeraControl Copyright User 2014 Handbook Potterycrafts Ltd. Date:

More information

Battery Charger JCB-FCH20LI2

Battery Charger JCB-FCH20LI2 Safety and operating manual Battery Charger JCB-FCH20LI2 ORIGINAL INSTRUCTIONS SAFETY INSTRUCTIONS WARNING: Read all safety warnings and all instructions.failure to follow the warnings and instructions

More information

ARC4800L Big Red Compressor System

ARC4800L Big Red Compressor System 350 S. St. Charles St. Jasper, In. 47546 Ph. 812.482.2932 Fax 812.634.6632 on the internet: www.ridetech.com ARC4800L Big Red Compressor System 2 ARC7000 ViAir 400C 150psi compressors 2 F9242 5 gallon

More information

Matson Jump Starter Operator s Manual

Matson Jump Starter Operator s Manual Matson Jump Starter Operator s Manual RA3800 SAVE THESE INSTRUCTIONS: This manual contains important safety and operating instructions for the RA3800 Jumpstart. Read through this owner s manual carefully

More information

TECHNICAL SPECIFICATIONS. CAPACITY per slot width 1ʺ 1.25ʺ 1.5ʺ HKPX2VC/A 2 modules devices HKPY2VC/A 3 modules devices

TECHNICAL SPECIFICATIONS. CAPACITY per slot width 1ʺ 1.25ʺ 1.5ʺ HKPX2VC/A 2 modules devices HKPY2VC/A 3 modules devices USER GUIDE Mobility MiX Cart HKPX2VC/A Mobility MiX Cart 30 HKPY2VC/A Mobility MiX Cart 45 TECHNICAL SPECIFICATIONS CAPACITY per slot width 1ʺ 1.25ʺ 1.5ʺ HKPX2VC/A 2 modules 30 24 20 devices HKPY2VC/A

More information

Zone 1 Linear Range - Installation Guide

Zone 1 Linear Range - Installation Guide Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text

More information

XS500 Load Bank. Read all instructions before using the load bank. Contents

XS500 Load Bank. Read all instructions before using the load bank. Contents XS500 Load Bank Read all instructions before using the load bank Contents Contents... 2 1) Receiving... 4 a. Load Bank... 4 b. Manual... 4 2) Specifications... 5 a. Mechanical... 5 i. Lifting... 5 ii.

More information

BOOSTER CABLES 1000 AMP Intelli-Check II

BOOSTER CABLES 1000 AMP Intelli-Check II BOOSTER CABLES 1000 AMP Intelli-Check II 1/4V SURGE PROTECTED SUITABLE FOR 4-8 CYLINDER COMMERCIAL, CONSTRUCTION & EARTH MOVING VEHICLES BATTERY CONDITION CHECK REVERSE POLARITY PROTECTED CHARGE CHECK

More information

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy 200 w/s 400 w/s Guide Number (m/100iso) 42 60 Recycling Time (100%) 0.3 ~ 0.9 sec 0.4 ~ 1.6 sec Flash Duration 1/700 ~ 1/1700 sec 1/700 ~ 1/1700

More information

OPERATIONAL INSTRUCTIONS

OPERATIONAL INSTRUCTIONS OPERATIONAL INSTRUCTIONS PRINTPro Universal FUME EXTRACTION UNITS July 2009 Page 1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 SAFETY INSTRUCTIONS... 3 Symbols used... 3 Electrical safety... 3 Dangers to

More information

Elmdene International Ltd

Elmdene International Ltd 1 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax: +44(0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK Web: www.elmdene.co.uk 13.8Vdc Switch Mode Power Supply GEN3-08-y

More information

XT INSTRUCTION MANUAL

XT INSTRUCTION MANUAL General Information The Apollo XT Remote fuel oil tank contents gauge is designed for use with oil tanks installed underground or positioned above safe working height where a split in the cable is required

More information

Daylight Rechargeable Portable Light

Daylight Rechargeable Portable Light Daylight Rechargeable Portable Light DH367 Please retain these instructions for future reference. These instructions are also available in other formats. Special warning Please note: Do not look directly

More information

RATE CONTROLLED TORQUE WRENCH TESTER

RATE CONTROLLED TORQUE WRENCH TESTER RATE CONTROLLED TORQUE WRENCH TESTER OPERATOR S HANDBOOK (PART NO. 34078) ISSUE 8 NORBAR TORQUE TOOLS LTD, Beaumont Road, Banbury, Oxfordshire, OX16 1XJ, UNITED KINGDOM Tel : + 44 (0) 1295 270333, Fax

More information

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

MULTI FUNCTION POWER PAK PLUS

MULTI FUNCTION POWER PAK PLUS MULTI FUNCTION JUMP START UP TO V8 PETROL & DIESEL 600A PEAK CURRENT RECHARGE USB POWER TOOLS TABLETS LAPTOPS MOBILE PHONES RECHARGE DEVICES ON-SITE VEHICLE JUMP STARTER KP1404 ED2 (June 15) Table of Contents

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS AUTOMATIC BATTERY CHARGER / MAINTAINER MODEL NO: CBO9-12 PART NO: 6267025 OPERATION & MAINTENANCE INSTRUCTIONS LS0315 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use

More information

SPECTRA ENGINEERING PTY LTD. MXPS15 Series Technical Manual

SPECTRA ENGINEERING PTY LTD. MXPS15 Series Technical Manual SPECTRA ENGINEERING PTY LTD MXPS15 Series Technical Manual MXPS15 Series Spectra Engineering Pty Ltd ABN 65 057 696 438 9 Trade Road Malaga Western Australia 6090 Tel: +61-8-92482755 Fax: +61-8-92482756

More information

EC225 Power Control System

EC225 Power Control System 1 Key Features 200W (~16A) combined Power Converter / Battery Charger - Converts the 230V mains supply into 12v DC power to run the leisure equipment and charge the battery using an intelligent two-stage

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

1.Safe testing IMPORTANT:

1.Safe testing IMPORTANT: Electricity is dangerous and can cause injury and death. Always treat it with the greatest of respect and care. If you are not quite sure how to proceed, then stop, take advice from a qualified person.

More information

HPP1 MK5 Owner s Manual

HPP1 MK5 Owner s Manual J Wolmarans Page 1 2016/09/15 Page 1 of 9 TABLE OF CONTENTS Page 1 Introduction...2 2 Models...2 3 Safety warnings...3 4 Contents...3 5 Installation...3 5.1 Mounting the unit:...3 5.2 Connecting the battery:...3

More information

CD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER

CD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER CD100 Series SINGLE COLUMN CARD DISPENSER Operators Manual Contents 1 Specifications...1 2 Installation...2 2.1 Unpacking and inspection...2 2.2 Installation...2 2.3 Electrical Connections...2 2.4 Initial

More information

1200W INVERTER GENERATOR

1200W INVERTER GENERATOR 1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use

More information

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810 5 IN 1 JUMP START MODEL NO: JS5IN1 PART NO: 6240005 OPERATION & MAINTENANCE INSTRUCTIONS LS0810 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please

More information

3.25 Ton Heavy Duty Floor Jack

3.25 Ton Heavy Duty Floor Jack Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS AUTOMATIC BATTERY CHARGER / MAINTAINER MODEL NO: CBO9-6/12 PART NO: 6267020 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use

More information

IN & TM Series User Manual

IN & TM Series User Manual IN & TM Series User Manual Models: IN3500LB, IN1600L, IN1600LB, IN120L, IN120LB, TM120L, TM120LB IN Series User Manual IN120L, IN120LB, IN1600L, IN160000LB, IN3500LB, TM120L & TM120LB Contents Equipment

More information

Installing Power Components

Installing Power Components This chapter provides instructions on how to install and reinstall power components in the Cisco NCS 4016 chassis. It also covers connecting and disconnecting power and powering on the chassis. The Cisco

More information

DC Master 24/ A

DC Master 24/ A USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015

More information

2. All electrical items covered by Portable Appliance Testing must be tested on a regular basis by a certified competent person.

2. All electrical items covered by Portable Appliance Testing must be tested on a regular basis by a certified competent person. Portable Appliance Testing (PAT) Procedure PORTABLE APPLIANCE TESTING (PAT) PROCEDURE 1 INTRODUCTION The University of the West of Scotland has a legal obligation to carry out, on a regular basis, electrical

More information

User Guide for Viridian EV Charging Stations

User Guide for Viridian EV Charging Stations User Guide for Viridian EV Stations Iss 3 - JULY 2015 Page 2 of 8 Thank you for purchasing a Viridian EV station. This guide is intended to instruct in the proper use of all models of Viridian stations.

More information

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS HEAVY DUTY BATTERY BOOSTERS / CHARGERS MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS 0614 Thank you for purchasing this CLARKE Battery Charger. These units are suitable for charging and boosting 12

More information

OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS AUTOMATIC BATTERY CHARGER / MAINTAINER MODEL NO: CBO9-12 PART NO: 6267025 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0118 - ISS 3 INTRODUCTION Thank you for purchasing this CLARKE product.

More information

Accessory Kit Estimated Fitting Time: 120 Minutes

Accessory Kit Estimated Fitting Time: 120 Minutes Landcruiser LC00 Tow-Pro Wiring Kit - Landcruiser LC00 Kit Part No: TPWKIT - 005 Accessory Kit Estimated Fitting Time: 0 Minutes FI88 Page 0 of Issue: Date: 7/09/07 07 General Notes Safety Notes Parts

More information

XL1000 Load Bank. Read all instructions before using the load bank. Contents

XL1000 Load Bank. Read all instructions before using the load bank. Contents XL1000 Load Bank Read all instructions before using the load bank Contents Contents... 2 1) Receiving... 4 a. Load Bank... 4 b. Manual... 4 2) Specifications... 5 a. Mechanical... 5 i. Lifting... 5 ii.

More information

HPP1 MK5 Owner s Manual

HPP1 MK5 Owner s Manual J Wolmarans Page 1 2017/03/07 Page 1 of 10 TABLE OF CONTENTS Page 1 Introduction...2 2 Models...2 3 Safety warnings...3 4 Features...3 5 Contents...3 6 Installation...3 6.1 Mounting the unit:...3 6.2 Connecting

More information

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16 JUMPSTART MODEL NO: JS900/JS910 PART NO: 6240010 & 6240020 OPERATING & MAINTENANCE INSTRUCTIONS GC10/16 INTRODUCTION Thank you for purchasing this CLARKE Jump-start. Before attempting to use this product,

More information

12 Volt 1500 Amp Intelli-Start LITHIUM JUMPSTARTER

12 Volt 1500 Amp Intelli-Start LITHIUM JUMPSTARTER 12 Volt 1500 Amp Intelli-Start LITHIUM JUMPSTARTER P/No. IS1500 IMPORTANT SAFETY INFORMATION Please read this manual thoroughly before use and store in a safe place for future reference. WARNINGS Do not

More information