IMPACT TESTING ON SAFETY GLAZING MATERIAL. Rendered to:

Size: px
Start display at page:

Download "IMPACT TESTING ON SAFETY GLAZING MATERIAL. Rendered to:"

Transcription

1 IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße Steyr Austria Report No: Test Date: 01/29/04 Report Date: 03/26/04 6 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 69ºF Duration of 75 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z ANSI Z Did Not Break 95 3 ANSI Z Did Not Break 95 4 ANSI Z CFR Did Not Break 95 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb Derry Court York, PA phone: fax:

2

3 IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße Steyr Austria Report No: Test Date: 01/30/04 Report Date: 03/26/04 8 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 66ºF Duration of 70 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z Did Not Break ANSI Z Did Not Break ANSI Z Did Not Break ANSI Z Did Not Break CFR Did Not Break 128 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb Derry Court York, PA phone: fax:

4

5 IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße Steyr Austria Report No: Test Date: 01/29/04 Report Date: 03/26/04 10 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 69ºF Duration of 75 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z Did Not Break ANSI Z Did Not Break ANSI Z Did Not Break ANSI Z Did Not Break CFR Did Not Break 161 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb Derry Court York, PA phone: fax:

6

7 IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße Steyr Austria Report No: Test Date: 01/30/04 Report Date: 03/26/04 12 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 67ºF Duration of 75 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z Did Not Break ANSI Z Did Not Break ANSI Z Did Not Break ANSI Z Did Not Break CFR Did Not Break 196 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb Derry Court York, PA phone: fax:

8

9 IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße Steyr Austria Report No: Test Date: 01/29/04 Report Date: 03/26/04 15 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 68ºF Duration of 75 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z Did Not Break ANSI Z Did Not Break ANSI Z Did Not Break ANSI Z Did Not Break CFR Did Not Break 243 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb Derry Court York, PA phone: fax:

10

11 IMPACT TESTING ON SAFETY GLAZING MATERIAL Rendered to: ECKELT GLAS GMBH Resthofstraße Steyr Austria Report No: Test Date: 01/29/04 Report Date: 03/26/04 19 mm Tempered Transparent Glass Size Classification: Unlimited Lab Temperature: 68ºF Duration of 75 ±5ºF: 48 Hours Test Size: 34" wide by 76" high All test specimens were destroyed by test or by our personnel and have been disposed of as trash. Impact Tests: Spec. Test Thickness, Impact Test Acceptance No. Standard millimeters Drop Height, Results, Criteria, inches grams grams 1 ANSI Z Did Not Break ANSI Z Did Not Break ANSI Z Did Not Break ANSI Z Did Not Break CFR Did Not Break 306 For ARCHITECTURAL TESTING, INC.: Justin M. Mann Technician Craig H. Wagner, P.E. Director - Code Compliance JMM:jmm/nlb Derry Court York, PA phone: fax:

12

AAMA THERMAL PERFORMANCE REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 3150 Curtain Wall TYPE: Glazed Wall System

AAMA THERMAL PERFORMANCE REPORT. Rendered to: UNITED STATES ALUMINUM. SERIES/MODEL: 3150 Curtain Wall TYPE: Glazed Wall System AAMA 507-07 THERMAL PERFORMANCE REPORT Rendered to: UNITED STATES ALUMINUM SERIES/MODEL: 3150 Curtain Wall TYPE: Glazed Wall System Report No: Report Date: 08/22/08 130 Derry Court York, PA 17406-8405

More information

AAMA THERMAL PERFORMANCE REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: 200 Series Curtainwall (E2297) TYPE: Glazed Wall System

AAMA THERMAL PERFORMANCE REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: 200 Series Curtainwall (E2297) TYPE: Glazed Wall System AAMA 507-03 THERMAL PERFORMANCE REPORT Rendered to: TUBELITE, INC. SERIES/MODEL: 200 Series Curtainwall (E2297) TYPE: Glazed Wall System Report No: Report Date: 05/23/07 130 Derry Court York, PA 17406-8405

More information

AAMA THERMAL PERFORMANCE REPORT. Rendered to: TORO ALUMINUM. SERIES/MODEL: Commdoor 225 Awning (Project Out) TYPE: Projecting, Awning

AAMA THERMAL PERFORMANCE REPORT. Rendered to: TORO ALUMINUM. SERIES/MODEL: Commdoor 225 Awning (Project Out) TYPE: Projecting, Awning Architectural Testing AAMA 507-12 THERMAL PERFORMANCE REPORT Rendered to: TORO ALUMINUM SERIES/MODEL: Commdoor 225 Awning (Project Out) TYPE: Projecting, Awning Report No: Report Date: 130 Derry Court

More information

AAMA THERMAL PERFORMANCE REPORT (Revised) Rendered to: UNITED STATES ALUMINUM

AAMA THERMAL PERFORMANCE REPORT (Revised) Rendered to: UNITED STATES ALUMINUM AAMA 507-07 THERMAL PERFORMANCE REPORT (Revised) Rendered to: UNITED STATES ALUMINUM SERIES/MODEL: 7600 Projected Vent TYPE: Projecting (Awning - Single) Report No: Original Report Date: Revised Report

More information

CREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System

CREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System Architectural Testing CREEP PERFORMANCE TEST REPORT Rendered to: TREX COMPANY LLC Seclusions Composite Privacy Fence System TYPE: Composite Fence System Report No.: Report Date: Expiration Date: 130 Derry

More information

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Report No.: A6458.01 801 18 Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas PRODUCT TYPE: Fiberglass In Swing Glazed Double Doors SERIES/MODEL:

More information

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Report No.: A6839.01 801 18 Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas PRODUCT TYPE: In Swing Fiberglass Double Doors with Speak Easy

More information

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas Architectural Testing ASTM E 1886 and ASTM E 1996 TEST REPORT Report No.: A6457.01 801 18 Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas PRODUCT TYPE: In Swing Fiberglass Door with Side Lites SERIES/MODEL:

More information

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC. AAMA/WDMA/CSA 101/I.S.2/A440-05 TEST REPORT Rendered to: MASTER WINDOW SYSTEMS, INC. SERIES/MODEL: Master 2000 Double Hung Window PRODUCT TYPE: PVC Double Hung Window Summary of Results Title Test Specimen

More information

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket TEST REPORT Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket Report No: Report Date: 10/31/12 130 Derry Court York, PA 17406-8405 phone:

More information

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. Architectural Testing NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: 143.191 Casement / Awning / Fixed Baseline Product

More information

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: SS 145.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: SS 145. Architectural Testing NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: 143.095 SS 145.095 SS Baseline Product for Validation

More information

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. Architectural Testing NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: 143.095 SH 145.095 SH 143.095 SH Common Head Baseline

More information

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina TEST REPORT Report No.: G4212.01-109-44 Rendered to: VELUX America LLC Greenwood, South Carolina PRODUCT TYPE: Skylight with Curb SERIES/MODEL: Specials Dome Skylight 0.118 thickness PC smooth/0.118 thickness

More information

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. Architectural Testing NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: 143.095 DH 143.195 DH 145.095 DH 145.195 DH Baseline

More information

New Gateway 101/I.S.2/A440

New Gateway 101/I.S.2/A440 Architectural Testing Informational Bulletin #16 March 7, 2005 Topic: Comparison of the new AAMA/WDMA/CSA 101/I.S.2/A440-05 to the previously published industry standards. The purpose of this ATI-TIPS

More information

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY SERIES/MODEL: 4000 / 4500 DuraGard XT Double Hung Report Number: Original

More information

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS CORPORATION Architectural Testing NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: PARAMOUNT WINDOWS CORPORATION SERIES/MODEL: ECO-View 6100/7100 Report Number: B6000.01-301-45

More information

CALIBRATION REPORT. Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas

CALIBRATION REPORT. Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas CALIBRATION REPORT Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas Report No.: 79241.01-801-47 Calibration Date: 12/14/07 Report Date: 03/20/08 2865 Market Loop Southlake, Texas 76092

More information

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent Architectural Testing PERFORMANCE TEST REPORT Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent This report contains in its entirety: Cover Page: 1 page Report Body: 6 pages

More information

PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION. B ml Container (Mfg. Date , Lot # 2K15)

PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION. B ml Container (Mfg. Date , Lot # 2K15) PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION B902-10 90 ml Container (Mfg. Date 1210151, Lot # 2K15) TEST REPORT #: 12-1381 TESTING PERFORMED FOR: STARPLEX SCIENTIFIC, INC.

More information

CE conform applications according to EN External door with thermal break System Forster unico

CE conform applications according to EN External door with thermal break System Forster unico CE conform applications according to EN 14351-1 External door with thermal break System Forster unico 2 Properties Table 1 Doors, opening outwards Change of dimension Resistance to wind load Air permeability

More information

PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION. B602-10, V302 and B202-1WNL Vial Variables TEST REPORT #:

PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION. B602-10, V302 and B202-1WNL Vial Variables TEST REPORT #: PRESSURE DIFFERENTIAL AND THERMAL SHOCK/PRESSURE DIFFERENTIAL EVALUATION B602-10, V302 and B202-1WNL Vial Variables TEST REPORT #: 13-1054 TESTING PERFORMED FOR: STARPLEX SCIENTIFIC, INC. 50A Steinway

More information

AAMA THERMAL PERFORMANCE REPORT. Rendered to: US ALUMINUM INC., DIVISION OF CR LAURENCE CO., INC.

AAMA THERMAL PERFORMANCE REPORT. Rendered to: US ALUMINUM INC., DIVISION OF CR LAURENCE CO., INC. Archi t ectural Testing THERMAL PERFORMANCE REPORT Rendered to: US ALUMINUM INC., DIVISION OF CR LAURENCE CO., INC. SERIES/MODEL: S80 Bi-Fold Door (1" Dual Glazed) TYPE: Swinging Door - Double Report No:

More information

oééçêí=çå=cáåçáåöë= OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018

oééçêí=çå=cáåçáåöë= OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018 oééçêí=çå=cáåçáåöë= = OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018 Commissioning Party: Renusol Europe GmbH Mr Nils Rossbach Piccoloministr. 2 51063 Cologne Testing location:

More information

Type 543. Three-way Ball Valve

Type 543. Three-way Ball Valve Three-way Ball Valve Type 543 General Size: ⅜ 2 Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seat: PTFE Seals: EPDM or FPM End Connection: Solvent cement socket, threaded, flanged,

More information

OFS Brands Test Facility Report No: OFSB Date: April 2, 2015 Page: 1 of 29. Test Report For: ANSI/BIFMA X Storage Units.

OFS Brands Test Facility Report No: OFSB Date: April 2, 2015 Page: 1 of 29. Test Report For: ANSI/BIFMA X Storage Units. Date: April 2, 2015 Page: 1 of 29 Test Report For: ANSI/BIFMA X5.9-2012 Storage Units FastenLink This report shall not be reproduced, except in full, without written permission from OFS Brands Quality

More information

Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment

Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment American Society of Sanitary Engineering Seal (Certification) Program Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment Tested under ASSE Standard 1022 ASSE: 2003 ANSI:

More information

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS Architectural Testing NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT Rendered to: PARAMOUNT WINDOWS SERIES/MODEL: 6700/ 6750/ 7700/ 8700/ 8750 Report Number: Report Date:

More information

WET PENDULUM SLIP RESISTANCE Job No: M14/7986

WET PENDULUM SLIP RESISTANCE Job No: M14/7986 ATTAR TEST REPORT NUMBER: 14/7986 The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. Accredited for compliance with ISO/IEC

More information

TEST REPORT. Report No.: G Rendered to: SKYCO SKYLIGHTS Costa Mesa, California

TEST REPORT. Report No.: G Rendered to: SKYCO SKYLIGHTS Costa Mesa, California TEST REPORT Report No.: G1418.01-301-44 Rendered to: SKYCO SKYLIGHTS Costa Mesa, California PRODUCT TYPE: Fall Protection Security Bars SERIES/MODEL: FSB-1A/FSB-10A/FSB-1/FSB-10 SPECIFICATION: Occupational

More information

Report No 2370/ This Report consists of 40 pages. Authority & date Request by Client dated 25 November 2010

Report No 2370/ This Report consists of 40 pages. Authority & date Request by Client dated 25 November 2010 Test Report Report No 2370/7612199 This Report consists of 40 pages Client Smarts Systems Limited Arnolds Way Yatton BS49 4QN Authority & date Request by Client dated 25 November 2010 Items tested 3 off

More information

14 April 2016 Total Pages: 2. WET PENDULUM SLIP RESISTANCE Job No: M16/10016

14 April 2016 Total Pages: 2. WET PENDULUM SLIP RESISTANCE Job No: M16/10016 ATTAR TEST REPORT NUMBER: 16/10016.2 The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. Accredited for compliance with

More information

PENTAGON PROTECTION USA

PENTAGON PROTECTION USA PENTAGON PROTECTION USA Shock Tube Testing for Window Systems March 2009 San Antonio, Texas ABS Consulting Project Number 2127174 ABSG Consulting, Inc. 14607 San Pedro, Suite 215 San Antonio, TX 78232

More information

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: EARTHWISE GROUP, L.L.C

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: EARTHWISE GROUP, L.L.C NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT (Revised) Rendered to: EARTHWISE GROUP, L.L.C SERIES/MODEL: 623.620 Patio Door Report Number: Original Report Date: Revised

More information

Flexible Arm Stand F 360. User Manual

Flexible Arm Stand F 360. User Manual User Manual To ensure proper use of this instrument as well as to avoid injury while operating instrument, understanding this manual completely before use is highly recommended. Flexible Arm Stand User

More information

Type 375. True Union Ball Valve

Type 375. True Union Ball Valve True Union Ball Valve Type 3 General Size: ⅜ 4 Material: PVC, CORZAN CPVC, or PPn Seat: PTFE Seals: EPDM or FPM End Connection: Solvent cement socket, threaded, flanged, PPro-Seal electrofusion socket

More information

TEST REPORT. : TS EN A1 Windows and Doors - Product Standard. : BM 72 Hinged Window System. : Burak Aluminyum San ve Tic. A.Ş.

TEST REPORT. : TS EN A1 Windows and Doors - Product Standard. : BM 72 Hinged Window System. : Burak Aluminyum San ve Tic. A.Ş. TEST REPORT Report Number : 020.413.1 / 2015 Report Date : 24 / 07 / 2015 Testing Reference Product Client : TS EN 14351-1 + A1 Windows and Doors - Product Standard : BM 72 Hinged Window System : Burak

More information

Test Report. Report No: BSTDG YRR-4 Date: Mar. 27, 2015 Page 1 of 7. :No.27, Shunsi Road, Ronggui Town, Shunde District, Guangdong Province

Test Report. Report No: BSTDG YRR-4 Date: Mar. 27, 2015 Page 1 of 7. :No.27, Shunsi Road, Ronggui Town, Shunde District, Guangdong Province Report No: BSTDG1503312211YRR-4 Date: Mar 27, 2015 Page 1 of 7 Applicant Address :FOSHAN BANGLISHI TRADING CO, LTD :No27, Shunsi Road, Ronggui Town, Shunde District, Guangdong Province The following sample(s)

More information

from one solar collector.

from one solar collector. The time has come. from one solar collector. Introducing PREVIOUSLY 2 separate collectors. Electricity or heat. BRAND-NEW 1 hybrid collector for electricity + heat. PHOTVOLTAIC SOLAR HEAT PHOTVOLTAIC SOLAR

More information

Report Issued: October 19, 2014 Project No.: 23942

Report Issued: October 19, 2014 Project No.: 23942 Report Number: 1052-14017 Report Issued: October 19, 2014 Project No.: 23942 Client: Showerstart LLC 15354 North 83 rd Way Suite 102 Scottsdale, AZ 85260 Contact: Mr. Jason Swanson Source of Samples: The

More information

600 Amp Surge Arrester

600 Amp Surge Arrester R&D Center 497 Schooley s Mountain Road Hackettstown, NJ 07840-3906 Tele: 908-852-1122 Fax: 908-813-2091 TEST REPORT NUMBER: 379-17-12164 DATE: 4-3-2012 REPORT OF TEST ON 600 Amp Surge Arrester Statements

More information

RSL Energy Efficiency and STC Ratings. Energy efficiency and beauty at your doorway!

RSL Energy Efficiency and STC Ratings. Energy efficiency and beauty at your doorway! RSL Energy Efficiency and STC Ratings Energy efficiency and beauty at your doorway! July 2017 U.S. ENERGY STAR Criteria for Doors The U.S. standards include criteria for air leakage. Swinging doors cannot

More information

LIPSTICK CHARGER POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

LIPSTICK CHARGER POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS LIPSTICK CHARGER POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS HALO LIPSTICK CHARGER From HALO, the LIPSTICK CHARGER is the definition of fashion meet function. This tiny lipstick is in fact

More information

CERTIFICATE of QUALITY TEST

CERTIFICATE of QUALITY TEST Test lab CERTIFICATE of QUALITY TEST according to DIN 55 350-18 - 4.3.4. DAP-PL-3439.00 Test report - No. 7564 / 09 Client FALCOM Wireless Communications GmbH Gewerbering 6 98704 Langenwiesen Equipment

More information

Type 567. Wafer Style Butterfly Valve

Type 567. Wafer Style Butterfly Valve Wafer Style Butterfly Valve Type 5 General Size: 2 12 Outer Body: Glass-filled PP Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seals: EPDM, FPM, PTFE/FPM Stem: 31 stainless steel Operation:

More information

Lug Style Butterfly Valve Type 578

Lug Style Butterfly Valve Type 578 Lug Style Butterfly Valve Type 58 General Size: 2 12 Outer Body: Glass-filled PP Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seals: EPDM, FPM, PTFE/FPM Stem: 31 Stainless steel Lugs:

More information

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE REPORT NUMBER 401-STF-09-002 SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE HYUNDAI MOTOR COMPANY 2009 HYUNDAI GENESIS FOUR-DOOR PASSENGER CAR NHTSA NO. C90501 U.S. DOT SAN ANGELO TEST

More information

INTERNATIONAL COURT OF APPEAL (I.C.A.) of the FEDERATION INTERNATIONALE DE L'AUTOMOBILE

INTERNATIONAL COURT OF APPEAL (I.C.A.) of the FEDERATION INTERNATIONALE DE L'AUTOMOBILE INTERNATIONAL COURT OF APPEAL (I.C.A.) of the FEDERATION INTERNATIONALE DE L'AUTOMOBILE Appeal submitted by the Fédération Internationale de l Automobile, on the grounds of Article 185 of the International

More information

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE REPORT NUMBER 401-STF-09-001 SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE GENERAL MOTORS CORPORATION 2009 CHEVROLET IMPALA FOUR-DOOR PASSENGER CAR NHTSA NO. C90100 U.S. DOT SAN ANGELO

More information

UN/SCETDG/43/INF.5. Packing requirements for UN1873. Transmitted by the Council on Safe Transportation of Hazardous Articles (COSTHA)

UN/SCETDG/43/INF.5. Packing requirements for UN1873. Transmitted by the Council on Safe Transportation of Hazardous Articles (COSTHA) Committee of Experts on the Transport of Dangerous Goods and on the Globally Harmonized System of Classification and Labelling of Chemicals UN/SCETDG/43/INF.5 Sub-Committee of Experts on the Transport

More information

Type 514, 515, 517, 519

Type 514, 515, 517, 519 Diaphragm Valve Type 514, 5, 517, 519 General : ½ 2 Material: PVC, CPVC, PROGEF Standard PP, PROGEF Natural PPn, ABS, SYGEF Standard PVDF, SYGEF Plus PVDF-HP Diaphragm: EPDM, FPM, NBR, PTFE/EPDM, PTFE/FPM,

More information

MITEQ AM-1185 SERIES AMPLIFIER

MITEQ AM-1185 SERIES AMPLIFIER MITEQ AM-1185 SERIES AMPLIFIER GAIN VAR. IMPED. NOISE P1 db NOM. FREQUENCY MODEL (±db) IN/OUT FIGURE (dbm) POWER OUTLINE NUMBER (Min.) (Max.) (Max.) (Ohms) (db, Typ.) (Typ.) VOLTS (ma) NO. 1 1000 AM-1185-1000

More information

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA PRO-TYP II Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA 3-349-884-03 1/10.15 Opening of Equipment / Repair The equipment may be

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

More information

Industry/PennDOT Initiative On Performance Testing. AN UPDATE January 22, 2019

Industry/PennDOT Initiative On Performance Testing. AN UPDATE January 22, 2019 Industry/PennDOT Initiative On Performance Testing AN UPDATE January 22, 2019 Outline Testing Modes A Review of Semi-Circular Bend (SCB) Test PA Industry Initiative on SCB Results & Observations Next Steps

More information

Test report No.: VU

Test report No.: VU Department of Environmental / Vibration Engineering Test report No.: 2017-0277-VU Date of test: June - July 2017 Testers: No. of pages: 13 Applicant/ manufacturer: Test specimens: Test procedures / bases:

More information

The reason for higher electric bills

The reason for higher electric bills The reason for higher electric bills William S. Bathgate, BS EE bill.bathgate@gmail.com 1 The new AMI electric meter block diagram The Switched Mode Power Supply, (SMPS) which injects high frequency Oscillations/Harmonics

More information

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W Customer Company & Address: MaxLite ADD: 12 York Ave, West Caldwell, NJ 07006 Contact Person: Francisco Garza Telephone: 973-244-7300x142 Telephone: fgarza@maxlite.com Manufacturer: Country of Origin:

More information

Medical Waste Transporters

Medical Waste Transporters Medical Waste Transporters 17 th Annual Lower Rio Grande Valley Water Quality Management & Planning Conference May 19-23, 2015 Jaya Zyman, P.E., Director Permitting and Registration Support Division Regulation

More information

One-line distributor e.g. VEI-A. One-line aggregate GEI-A

One-line distributor e.g. VEI-A. One-line aggregate GEI-A Ungültig!!! Ersatz: P0768 GE71 One-line aggregate GEI-A Use: This aggregate is used as pump in central lubrication systems that are based on the one-line principle. General construction: Essentially, the

More information

Type Electrically Actuated Ball Valve

Type Electrically Actuated Ball Valve Electrically Actuated Ball Valve Type 179-184 General Size: ⅜ 4 Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seat: PTFE Seals: EPDM, FPM End Connection: Solvent cement socket, threaded,

More information

TEST REPORT. Report Number : / Report Date : 12 / 03 / : TS EN A1 Windows and Doors - Product Standard

TEST REPORT. Report Number : / Report Date : 12 / 03 / : TS EN A1 Windows and Doors - Product Standard TEST REPORT Report Number : 020.530.1 / 2016 Report Date : 12 / 03 / 2016 Testing Reference : TS EN 14351-1 + A1 Windows and Doors - Product Standard Product : Asistal TH 78 Door and Window System ( Tilt

More information

Documents and Addresses

Documents and Addresses Report No.: 05-035-MS/E Sheet: 2 Documents and Addresses Accreditation The Prüffeld der Schaltwerke, Berlin has been approved by the DATech (German accreditation body for technology) according to EN ISO/IEC

More information

Endurance Testing of Redesigned Tab Spring for MI-RAMS System

Endurance Testing of Redesigned Tab Spring for MI-RAMS System Endurance Testing of Redesigned Tab Spring for MI-RAMS System by Mark R. Probst ARL-TN-0388 April 2010 Approved for public release; distribution unlimited. NOTICES Disclaimers The findings in this report

More information

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength Report No: 181947 Test of: Reversible aluminium/timber window Tested to: BS 6375-2:2009 Performance of windows & doors Part 2: Operation & strength For: A/S Peder Nielsen Beslagfabrik Norregade 25 Bronderslev

More information

SHINE 3000 POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

SHINE 3000 POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS SHINE 3000 POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS HALO SHINE 3000 Thank you for choosing HALO. Innovative, fashionable and easy to use, the HALO SHINE 3000 provides a powerful and universal

More information

Graphic. Air Compliance Issues and Solutions. Sunita Dhar, PhD Senior Scientist First Environment 91 Fulton Street, Boonton

Graphic. Air Compliance Issues and Solutions. Sunita Dhar, PhD Senior Scientist First Environment 91 Fulton Street, Boonton Graphic Air Compliance Issues and Solutions Sunita Dhar, PhD Senior Scientist First Environment 91 Fulton Street, Boonton Agenda Permitting NJDEP - New General Permits for Emergency Generators NJDEP -

More information

ASTM B117 Testing Quality Control

ASTM B117 Testing Quality Control ASTM B117 Testing Quality Control ASTM B117 Testing, also known as a Standard Practice for Operating Salt Spray (Fog), is used to analyze relative corrosion for specimens of metals and coated metals exposed

More information

PRODUCT DATA SHEET P5

PRODUCT DATA SHEET P5 PRODUCT DATA SHEET 2 - PRODUCT DATA SHEET SPECIFICATIONS LIGHT FUNCTIONS Power TECHNICAL DATA Length defocused [mm] Length focused [mm] Head diameter [mm] Tube diameter [mm] Weight incl. batteries [g]

More information

Rotameters. Variable Area Flow Meters

Rotameters. Variable Area Flow Meters Variable Area Flow Meters Rotameters General Size: ⅜ 2½ Total Flow Range:. 264 gpm Tube Material: PA, PSU, PVC transparent Seal: EPDM, FPM Float: PVDF, PVDF-HP transparent En Connection: Solvent cement

More information

GENERATOR SHELTER IMPACT TEST REPORT (.08 Material)

GENERATOR SHELTER IMPACT TEST REPORT (.08 Material) GENERATOR SHELTER IMPACT TEST REPORT (.08 Material) Florida Division of Emergency Management 2555 Shumard Oak Boulevard Tallahassee, FL 32399 Office: 850-413-9969 Department of Management Services 4050

More information

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5 Page: 1 of 5 IGEPA GROUP GMBH & CO. KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : MASTER JET S PREMIUM MESH

More information

Sound absorption coefficient ISO 354 Measurement of sound absorption in reverberation rooms

Sound absorption coefficient ISO 354 Measurement of sound absorption in reverberation rooms Test specimen: Fabric type Sonic, art.-no. 10810, fabric type Sonic, article no. 10810 material 94 % PES CS, 6 % PES area specific mass m" = 175 g/m² airflow resistance Rs = 484 Pa s/m thickness d = 7

More information

Electrical Power Generator Use and Procurement Guidance

Electrical Power Generator Use and Procurement Guidance Electrical Power Generator Use and Procurement Guidance For compliance with applicable air emission control regulations December 2016 Prepared by: Syracuse University Environmental Health & Safety Services

More information

FULL PORT STANDARD PORT COMPLETE SIZE RANGE. Superior Flow Easy Operation Full Traceability State-of-the-Art Manufacturing

FULL PORT STANDARD PORT COMPLETE SIZE RANGE. Superior Flow Easy Operation Full Traceability State-of-the-Art Manufacturing FULL PORT STANDARD PORT COMPLETE SIZE RANGE Superior Flow Easy Operation Full Traceability State-of-the-Art Manufacturing An Employee-Owned Total Quality Management Company Made in America The Polyball

More information

Reference Number: SMS-3517-L1A, Rev 0 Date: November 7, 2014

Reference Number: SMS-3517-L1A, Rev 0 Date: November 7, 2014 Reference Number: SMS-3517-L1A, Rev 0 Date: November 7, 2014 Owen Oil Tools LP 12001 County Road 1000 Godley, Texas 76044 Attention: Subject: Ben Potter Shipping Classification Recommendation for the OOT-APRV-064

More information

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5

TEST REPORT No. : SHCCM Date : Mar. 12, 2013 Page: 1 of 5 Page: 1 of 5 IGEPA GROUP GMBH & CO.KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : MASTER JET S FRONTLIT 510

More information

Prüffeld der Schaltwerke

Prüffeld der Schaltwerke Report No.: 16-043-MS Sheet: 2 Notes 1. The testing station of the Siemens switchgear factory (Prüffeld der Schaltwerke),, Berlin, has been approved by the DAkkS (German accreditation body) for rendering

More information

Slide-locks Enforcement Policy, Inspection Procedures and Performance Guidance Criteria

Slide-locks Enforcement Policy, Inspection Procedures and Performance Guidance Criteria SUBJECT: Purpose: Scope: Slide-locks Enforcement Policy, Inspection Procedures and Performance Guidance Criteria This Instruction establishes enforcement policies, inspection procedures and performance

More information

Distributed By Aetna Plastics Pneumatically Actuated Diaphragm Valve DIASTAR Ten and TenPlus General Size: ½ 2 Material: PVC, CP

Distributed By Aetna Plastics   Pneumatically Actuated Diaphragm Valve DIASTAR Ten and TenPlus General Size: ½ 2 Material: PVC, CP Pneumatically Actuated Diaphragm Valve DIASTAR Ten and TenPlus General : ½ 2 Material: PVC, CPVC, PROGEF Standard PP, PROGEF Natural PPn, ABS, SYGEF Standard PVDF, SYGEF Plus PVDF-HP Diaphragm: EPDM, FPM,

More information

Applicable Product Numbers:

Applicable Product Numbers: Product: Lithium Thionyl Chloride (Li-SOCl2)battery Date: 2/16/2018 Revision: B Applicable Product Numbers: Document Number: LTC-3PN, LTC-7PN, LTC-7P, LTC-7PMP, LTC-7PMS, LTC- 15MC, LTC-16M, LTC-16MC,

More information

Wood and Aluminum EnduraClad Exterior 6' 8" and 6' 10" Size Tables

Wood and Aluminum EnduraClad Exterior 6' 8 and 6' 10 Size Tables 6' 8" and 6' 10" Size Tables Scale 1/8" = 1' 0" All doors and sidelights are glazed with tempered glass. For windows and patio doors with HurricaneShield impact-resistant glass, see product instructions

More information

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference: Exova Warringtonapt Key Industrial Park Fernside Road Willenhall West Midlands WV13 3YA T : +44 (0) 1902 722 122 F : +44 (0) 1902 727 242 E : willenhall@exova.com W: www.exova.com BS EN 14351-1:2006 Test

More information

PRODUCT EVALUATION REPORT

PRODUCT EVALUATION REPORT SPUTO AND LAMMERT ENGINEERING, LLC STRUCTURAL ENGINEERS 10 SW 1 ST AVENUE, GAINESVILLE, FL 32601 PHONE: 352-378-0448 FAX: 352-373-1331 E-MAIL: sputoandlammert@mindspring.com PRODUCT EVALUATION REPORT MANUFACTURER:

More information

Superior by Design. Euro vista wood impact/non impact rated wood folding door systems

Superior by Design. Euro vista wood impact/non impact rated wood folding door systems Superior by Design. Euro vista wood impact/non impact rated wood folding door systems Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL 15472 www.euro-wall.com

More information

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10

Test Report No.: SZTY TS Date: DEC 04, 2012 Page 1 of 10 Test Report : SZTY1211030991TS Date: DEC 04, 2012 Page 1 of 10 HAPPY ARTS&CRAFTS(NINGBO)CO.,LTD/ HAPE INTERNATIONAL(NINGBO)LTD 9-27 NANHAI ROAD, DAGANG INDUSTRIAL CITY, BEILUN, NINGBO, CHINA PC:315800

More information

TEST REPORT. : TS EN A1 Windows and Doors - Product Standard : ASISTAL LS 60 SERIES HEBE-SCHIEBE SYSTEM

TEST REPORT. : TS EN A1 Windows and Doors - Product Standard : ASISTAL LS 60 SERIES HEBE-SCHIEBE SYSTEM TEST REPORT Report Number : 020.557.1 / 2016 Report Date : 05 / 05 / 2016 Testing Reference Product : TS EN 14351-1 + A1 Windows and Doors - Product Standard : ASISTAL LS 60 SERIES HEBE-SCHIEBE SYSTEM

More information

Simply Sliding Door Systems

Simply Sliding Door Systems Simply Sliding Door Systems 1 Sliding Door Systems at a Glance Glass sliding doors offer a wide array of application possibilities in diverse living and working interiors. Apart from serving as interior

More information

Originally Issued: 09/26/2012 Revised: 09/29/2017 Valid Through: 09/30/2018

Originally Issued: 09/26/2012 Revised: 09/29/2017 Valid Through: 09/30/2018 EVALUATION SUBJECT: FAKRO FX, FV FVE, FX-EL, FV-ELA, AND FVE-ELA SKYLIGHTS REPORT HOLDER: FAKRO GROUP 144A WEGIERSKA STREET 33 300 NOWY SACZ POLAND 48 18-444 0444 www.fakro.info CSI Division: 08 00 00

More information

Work Zone Safety Initiatives and Research Efforts. Irene Soria Safety Evaluation Engineer Illinois Department of Transportation Safety Engineering

Work Zone Safety Initiatives and Research Efforts. Irene Soria Safety Evaluation Engineer Illinois Department of Transportation Safety Engineering Work Zone Safety Initiatives and Research Efforts Irene Soria Safety Evaluation Engineer Illinois Department of Transportation Safety Engineering TES Conference - October 17 th, 2012 Outline Work Zone

More information

ANSI/API Standard 607 Sixth Edition 2010 ISO 10497: 2010 Fire Test Certificate

ANSI/API Standard 607 Sixth Edition 2010 ISO 10497: 2010 Fire Test Certificate ANSI/API Standard 607 Sixth Edition 2010 ISO 10497: 2010 Fire Test Certificate Name of Manufacturer: ValvTechnologies, Inc. Test Date: 10/26/2010 Designation of Valve: Ball Valve NexTech Series Report/Certificate

More information

Diaphragm Valve MV 310

Diaphragm Valve MV 310 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Application chemical plants water treatment Utilisation

More information

VIBRATION AND MECHANICAL SHOCK TEST REPORT

VIBRATION AND MECHANICAL SHOCK TEST REPORT Report No. :DH1701190024A-1 Version:A VIBRATION AND MECHANICAL SHOCK TEST REPORT Company :OTO Photonics Inc. Address :9F-5,No. 27, Guanxin Rd., East Dist., Hsinchu City 30072, Taiwan(R.O.C.) Sample Name

More information

Up-Coming Diesel Fuel and Exhaust Emissions Regulations For Mobile Sources. Parminder Khabra RDECOM-TARDEC TACOM LCMC March 22, 2006 JSEM

Up-Coming Diesel Fuel and Exhaust Emissions Regulations For Mobile Sources. Parminder Khabra RDECOM-TARDEC TACOM LCMC March 22, 2006 JSEM Up-Coming Diesel Fuel and Exhaust Emissions Regulations For Mobile Sources Parminder Khabra RDECOM-TARDEC TACOM LCMC March 22, 2006 JSEM Report Documentation Page Form Approved OMB No. 0704-0188 Public

More information

Reference Number: SMS-4211-L1, Rev 0 Date: May 2, 2018

Reference Number: SMS-4211-L1, Rev 0 Date: May 2, 2018 Reference Number: SMS-4211-L1, Rev 0 Date: May 2, 2018 Manufacturer: Owen Oil Tools 12001 Country Road 1000 Godley, Texas 76044 Subject: Shipping Classification Recommendation for OOT-APRV-066 Fluid Sensitive

More information

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6

Test Report NO. AJHL FB Date: JUN.21, 2016 Page 1 of 6 Test Report. AJHL1606005783FB Date: JUN.21, 2016 Page 1 of 6 IGEPA GROUP GmbH & CO., KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was / were submitted and identified on behalf of the

More information

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: CR LAURENCE CO., INC.

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: CR LAURENCE CO., INC. FRC U-FACTOR, SHGC, VT, & CODESATIO RESISTACE COMPUTER SIMULATIO REPORT Rendered to: CR LAURECE CO., IC. SERIES/MODEL: StormWall XL Curtain Wall Report umber: Report Date: 10/14/16 FRC U-FACTOR, SHGC,

More information

Blast Protection Damper

Blast Protection Damper Protection Damper plate shown as transparent height width 250mm wide 6.35mm thick blast plate bolted to damper frame 178mm 250mm standard depth 76mm standard flange Application The damper is designed for

More information