REMEZ REMEZ GATE OPERATORS SWING GATE MOTORS REMEZ STANDARD / FAST / HEAVY DUTY SWING GATE MOTORS 220 VOLT A/C AND 12 VOLT D/C

Size: px
Start display at page:

Download "REMEZ REMEZ GATE OPERATORS SWING GATE MOTORS REMEZ STANDARD / FAST / HEAVY DUTY SWING GATE MOTORS 220 VOLT A/C AND 12 VOLT D/C"

Transcription

1 REMEZ GATE OPERATORS SWING GATE MOTORS REMEZ STANDARD / FAST / HEAVY DUTY SWING GATE MOTORS 220 VOLT A/C AND 12 VOLT D/C REMEZ DOMESTIC LIGHT DUTY SWING MOTORS 12 VOLT D/C Remez Gate Operators Installation / Commissioning

2 INSTALLATION OF SWING GATE MOTORS INTRODUCTION The successful operation of any automation depends to a great deal on the installation. 1. Ensure that the correct motor has been chosen for the particular application. Important factors to consider when measuring up a SWING gate for automation are laid out later. 2. Plan the job carefully. Time costs money and if all the different steps to complete the automation have not been carefully thought through, unnecessary time will be wasted. In other words each step must be carefully planned. 3. Read the Manual. Follow the guidelines laid out in the installation manual, in other words if in doubt "Read the manual". Not only will a thorough understanding of the installation procedure result in reliable operation of the system, there are many safety requirements, which must be adhered to as detailed. WORK NEATLY Take care always to complete each step of the installation to the best of your ability. This includes among many things making sure that: The operator and rack are securely installed, straight and level. Cabling is color-coded, the correct cabling is used and the cabling is neatly routed and terminated. Any concrete works properly finished off. All bare metal parts are painted after the installation using a suitable primer and finishing coat. Remez Gate Operators Installation / Commissioning

3 Take pride in the work that is done and make sure that each installation can be used as a future reference. DO THE JOB RIGHT THE FIRST TIME! Important Safety Instructions SUMMARY OF INSTRUCTIONS UNDERSTAND FULLY ALL THE INSTRUCTIONS IN THE MANUAL DON T LET CHILDREN OR PETS PLAY IN THE VICINITY OF THE GATE WHILE DOING THE INSTALLATION BEFORE ATTEMPTING ANY WORK, CUT ELECTRICAL POWER TO THE OPERATOR AND WHERE APPLICABLE DISCONNECT THE BATTERY. MAKE SURE THAT SAFETY DEVICES SUCH AS INFRA RED BEAMS WILL BE INSTALLED OR AS A MINIMUM, HAVE BEEN RECOMMENDED TO THE CLIENT. MAKE SURE THAT THE OPERATION OF THE SYSTEM IS CLEARLY EXPLAINED TO THE END USER AT THE TIME OF HANDOVER. FACTORS TO CONSIDER WHEN SPECIFYING A SWING GATE OPERATOR? Type of Load. When automating a SWING gate it is important to understand the type of load that exists. A gate whether it is a swing or slider is known as an inertial load. In layman's terms this means that majority of the effort is required to get the gate moving with minimal effort required to keep the gate moving. There are three measurements used to describe the loading of the gate. 1. The MASS of the Gate. It is measured in kg, where the mass determines the inertia of the system. The gearbox and gear set must suitably strong enough to withstand the inertial forces generated by the gate. 2. Pull Force. It is measured in kgf (kilogram force), where this measurement is of the friction presented by the hinges and wind resistance. The motor of the operator must be able to develop sufficient torque to overcome the friction in the gate and get the gate moving and keep the gate moving. Remez Gate Operators Installation / Commissioning

4 Examples to consider: A heavy gate, which has been properly installed and swings very smoothly, might be perceived to be adequate for a smaller operator even if the motor of the operator can drive the gate. However will the gearbox and gear set of this operator be strong enough to handle the inertial load of this big gate. On the other hand consider a gate installation where the gate is very light but badly installed such that the gate slides very poorly with lots of friction. Even if a small operator can handle the inertial load of the gate, will the motor be strong to move the gate? 3. Duty Cycle / Gate Usage. Very simply when specifying a gate operator it is important to determine how often the motor will be required to operator per day. Duty cycle is the percentage of time the motors operates relative to the total time. The total time being the run time plus the time that the gate stays open and closed. In the case of domestic installations this very seldom a consideration. However from light industrial; to heavy industrial applications, usage can be a very limiting factor for the operator. Unfortunately in many high frequency applications the situation is aggravated by the fact that the operating time is not evenly spread over a 24 hour period. It occurs in peaks. Take for instance a townhouse complex. Majority of the openings and closings occur for say an hour, when the residents leave in the morning and similarly a peak period in the afternoon, when they return. Depending on the environment, during these peak times the motor could operate almost continuously, and if the motor does not have a sufficiently high duty cycle rating it is likely to shutdown prematurely due to thermal overload. What are these limitations? In case of AC motors, it is the heat generated by the motor when it is operating. When used excessively the motor overheats and shuts down. For a specific application the operator selected must be able to sufficiently dissipate the heat generated due to the number of operations without going into "thermal overload". AIR COOLING Your basic operator is purely air-cooled. It relies on natural convection to cool the motor. This type of cooling is not very effective particularly as the motor is enclosed within the cover of the operator, allowing very little air circulation. The duty cycle of air cooled motors varies from 20% to 40%. Remez Gate Operators Installation / Commissioning

5 FORCED AIR COOLING This operator is an air-cooled unit except there is fan which blows air over the motor. Depending on the efficiency of the airflow and the volume of air that the fan can deliver the convection cooling process cab be significantly improved and in some instances motors can operate at a 100% duty cycle. With DC motors, although the motor runs very cool, the power supply is the limiting factor. Battery driven systems: The battery, which is the primary power source, will only have a small trickle charger re-charging the unit. Therefore the battery must have sufficient capacity to cope with the usage during a specific period of time without relying on the trickle charger to re-charge the battery during this period. Having selected the correct capacity battery it is then necessary to ensure that the trickle charger recharge the battery each day taking into account. SUMMARY If confronted with an installation where the duty cycle poses a problem, how can one solve it? Install a cooling fan - this option is only open if the motor is air-cooled. It does not help to try to force cool an oil-cooled operator. Adjust the auto close time. If one can hold the gate open for a longer period of time allowing the motor more time to cool, the duty cycle will improve. PRE-INSTALLATION CHECK OF THE SWING GATE 1. PROPER REAR MECHANICAL END STOP FITTED. 2. GATE IN MANUAL MODE SWINGS FREELY. 3. GATE SWINGS LEVEL (USE A SPIRIT LEVEL) 4. BATTERY CHARGING PROPERLY (13.6V) 5. BATTERY VOLTAGE WITH MOTOR RUNNING (12V or more) 6. ENSURE THERE IS A GAP BETWEEN LEAVES. CABLE REQUIREMENTS 220 VOLT AC MAINS SUPPLY REQUIRED FOR REMEZ 1103 / 1105 / 2105 / 2115 GATE MOTORS Cabling is an important aspect of the installation to ensure a reliable system. Most importantly is the AC mains supply to the operator. It is critical that the correct cabling and procedures as detailed below are followed. This is the most commonly installed system as in many instances the gate installation requires a mains supply for powering courtesy / security lights at the entrance. Remez Gate Operators Installation / Commissioning

6 What are the cabling and procedural requirements? a) It is always recommended to use three-core steel wired armoured cable (SWA) between the house and the gate. The armouring provides the cabling with adequate protection against a person accidentally cutting the cable and being electrocuted. In addition it provides a very effective metal screen against secondary lightning surges being induced in the cable. To be buried 500 mm below the surface. b) An alternative to SWA cable is Norsk or Surfex cable. This cable is available with three insulated conductors for LIVE, NEUTRAL and EARTH. The cable has a thin aluminum foil sheath around the conductors and then a final insulating PVC layer. The cable does not provide the same mechanical strength as SWA cable and therefore can only be used as an outside cable if buried 500 mm underground. The aluminum foil provides a certain amount of screening against surges. c) At the gate the mains supply cable whether SWA or Norsk must be routed via a double pole isolator before terminating onto the gate operator. The double pole isolator for switching both the LIVE and NEUTRAL supplies must be housed in its own weatherproof housing and mounted within 1m of the motor. d) At the house or main building of the installation, the mains supply cable must be terminated via a circuit breaker inside a distribution board of the mains reticulation. e) The circuit breaker must be rated to protect the cable used between the house and gate against the highest current envisaged to be drawn by the system. The cable thickness is similarly determined according to the envisaged load to be drawn at the gate. Although the gate operator will require no more than 0.5mm2 cable, to allow for courtesy lights or other peripherals to be fitted no less than a 1.5mm2 should be specified. If the distance between the distribution board and the gate is more than 50m this cable thickness should be increased to 2.5mm2. CABLE REQUIREMENTS 12VOLT DC SUPPLY REQUIRED FOR REMEZ 1250 / 2105 D/C / 2210 GATE MOTORS Low Voltage Supply to the Gate (Applicable to 1250 / 2105 D/C / 2210 gate motors only) This option is only available to battery driven systems where the battery is the primary power source. The mains supply required is openly to trickle charge the battery and therefore it is sufficient to run a low voltage feed to the gate to operate the charger unit. The type of installation has the following advantages: It is not necessary to have an electricians certificate / qualifications to make this installation. Remez Gate Operators Installation / Commissioning

7 It is less expensive as it is not necessary include components such as circuit breakers and double pole isolators. a) Recommended is the use of three-core steel wired armoured cable (SWA). Besides the armouring giving the cable adequate mechanical strength against accidental cutting, the armouring provides excellent screening against induced lightning. b) However as the supply to the gate is safe low voltage, the Norsk cable referred to above is more than adequate from a safety consideration. However to reduce the incident of induced lightning it is still recommend to bury the cable as deep as possible in the ground. c) At the gate, the cable can be terminated directly onto the controller. d) At the house or building the cable is terminated onto a "plug in transformer" and plugged directly into a standard 15-amp plug point. e) Cable thickness: As it is a low voltage feed between the plug in transformer in the house and the charger unit at the gate, the current flow required to re-charge the battery is proportionally higher. The minimum thickness of cable that can be used is 1.0 mm2. if the distance between the transformer and the gate operator is greater than 40m then a 2.5mm2 cable is recommended. Solar Charging System (Applicable to 1250 / 2105 D/C / 2210) A major benefit of the battery driven system is that in applications where there is a large distance between the house and the gate making the cost of cabling very high, alternative power source such as SOLAR CHARGING can be used. The type of installation has the following advantages: It is not necessary to have an electricians certificate / qualification to make this installation. The system is less susceptible to lightning strikes as there are no long cable feeding into the unit, which can act as aerials for picking up induced lightning surges. A disadvantage of the solar installation is that the capital cost of the equipment is high and it is only offset by not having to install cabling between the house and the gate. If however communication equipment such as an intercom is required, cabling and cabling trenches needs to be installed, then option 2 becomes a more viable route. Cabling and equipment requirements for solar system a) Typically a 20-watt solar panel will provide adequate charging of the battery in a domestic application where the daily usage does not exceed 15 cycles. For bigger installations. b) The solar panel must be supplied with a dedicated high efficiency solar regulator. c) No less than a 45amp Hour DEEP CYCLE battery should be installed. A separate weatherproof enclosure will be required to house the battery. Remez Gate Operators Installation / Commissioning

8 Refer to the solar panel selection guide for more information about the mounting position and angles of the solar panel etc. Other cabling - refer to the cable guide provided in the respective installation manuals and note the following: CABLING FOR ACCESSORIES For infra red beams, radio receivers, loops, intercoms, switches, keypads etc always use a multi stranded insulated wire - size 0.5 mm2. CABLE ROUTING Never forget to install the cabling before throwing the final concrete to secure the foundation plate. Feed through the cable plate sufficient length of cable in order to be able to route the cable neatly into the operator. Allow +/- 380mm length where 350mm of the outer sheathing is stripped back leaving only 30mm of the full thickness of the cable sticking above the plate. It is recommended that the cable is stripped prior to installing the gearbox. Ensure that the cable entry holes are properly sealed with silicon to prevent the ingress of insects. Although there is space allowed to route cabling into the gate motors, it is important to: Only route the cables that are needed to terminate onto the control board. Route the cable up in front of the battery and make sure that they are fed through the slots provided on the controller plate (1103 / 1250) Ensure that the wires are not under tension when terminating onto the controller. Allow a large radius half loop in each wire before each termination. Remez Gate Operators Installation / Commissioning

9 SELECTION OF SUITABLE REMEZ MOTOR Armed with the above information now choose a suitable Remez Swing Gate Motor 2210 Remez Light Duty D/C 12 volt battery operated system. This system is suitable for small unclad gates where convenience is paramount to security, however, additional security can be installed in the form of an electromechanical lock which is controlled by the control panel Remez Heavy Duty D/C 12 volt battery operated system. This system is suitable for small to large clad or unclad gates. There are three versions of this model. i) Standard opens in 16 seconds for light to medium gates (Domestic) ii) Fast opens in 8 seconds for light to medium gates (Domestic and Complex) iii) H/D opens in seconds for heavier gates ( Domestic and Complex) Special situation like Out opening and under gate operations can be used with these motors. For more information consult your nearest Remez dealer / 2115 Remez 220 volt operated systems. i) Remez Standard 220 volt A/C swings, open in 15 seconds, light to medium gates. ii) Remez 210-Fast 220 volt A/C swings, open in 7 seconds, light to heavy gates. iii) Remez 2115-Heavy Duty 220volt A/C swings, opens in 23 seconds, heavy gates or gate with high duty cycle or in windy areas. APPROXIMATE SIZES AND WEIGHTS OF GATES SINGLE SWING MOTOR 220 Volts 2105 (See through gate, UNCLAD) 350kg Long Arm 4m x 2.3m DOUBLE SWING MOTOR 22O Volts 2105 Standard (see through gate, UNCLAD) 350kg Short Arm 2.5 m x 3m 2105 FAST (see through gate, UNCLAD) 350kg Short Arm 2.5 m x 3m 2115 Heavy Duty Swing (Solid Gate, CLAD) 800kg Long Arm 4m x 3m 2115 Heavy Duty Swing (Solid Gate, CLAD) 500kg Short Arm 2.5m x 3m 12V DC SWING 2210 DOUBLE SWING 350KG 3m X 1.8m 2105 DOUBLE SWING D/C 12V kg 3m X 3m Remez Gate Operators Installation / Commissioning

10 MOTOR POSITION NORMAL OPERATION L OR FEN PILLAR A HINGE GATE CLOSED B = 500 mm FROM HINGE C = 500 mm FROM HINGE D GATE OPEN MOTOR SHAFT F D1 A = B = C = D = D1 = F = B = C = D1 = Hinge of gate. STANDARD ARMS: Measure 500mm from center of hinge to B. Make a mark on the gate and on the ground at C. Open gate and mark 500mm on the ground at C. Draw a line from B through C to D. The motor drive shaft D, must be placed on the diagonal line with the Tube / Pedestal facing the gate hinge. Minimum distance between wall and gate, in the open position, is 660mm. If you can cut through the wall, to allow free movement of the swing arm, the minimum distance would be 410mm. Minimum 100mm MOTOR BOX TO PROTUDE FROM THE GROUND A MINIMUM OF 200mm 1000mm 1000mm 1260mm or 800mm. LONG ARMS Remez Gate Operators Installation / Commissioning

11 MOTOR POSITION OUT SWINGING GATES HINGE 500mm PILLAR C B GATE Bracket 360mm D 100mm R EMEZ C Aluminum cover Motor Shaft 1) Measure 500mm between point "A" (center of hinge) and "B" on gate. "B" is the position of your gate bracket. 2) Measure and mark a point "D" from "A" when the gate is in the open position. 3) Measure and mark point "C" 100mm from "D". 4) Shaft must be on point where line "D" crosses "C" 5) Arm to use must be 150mm long. 6) Pipe must be +/- 1.5m long. (adjusted to fine tune) HINGE 500mm PILLAR PILLAR GATE PIPE ARM REMEZ Aluminum cover Remez Gate Operators Installation / Commissioning

12 MECHNICAL MOUNTING DETAILS INSTALLING THE FOUNDATION BOX. Min 100mm of box to protrude from ground Solid concrete base must be used to set box Before any concrete is thrown please ensure that all cables/conduiting are in place and sealed. LIGHTNING PROTECTION When installing a gate system guarding against lightning is particularly important to increase the longterm reliability of the system. Lightning protection should be designed into the installation from the start. As mentioned earlier the type of installation of the mains supply cabling plays an important role in reducing the incidence of induced lightning surges. Screened cable always recommended where the screening of the cable must be effectively earthed. The cable must be buried as deep as possible into the ground. Recommended 500 mm below ground level. The lightning protection circuitry built into the ALL Remez gate controllers requires good earthing to be effective. The most effective earth to use is the mains supply earth. However as the length of the mains supply cable increases, the effectiveness of this earth reducers. Therefore it is always recommended to install a I meter earth rod right next to the operator using a 4 mm2 copper earth wire to link the earth rod to the earth connections inside the operator. In addition or alternatively if it is possible to identify a metal water line close to the operator this would be preferable to the earth rod. In bad lightning areas it is also recommended that an additional "lightning surge arrestor unit "(40ka double pole device) connected inside the operator between the mains supply and the charger. Make sure that the earth of this device and the other earth points inside the controller are firmly bonded together and kept as close as possible to the earth spike. Remez Gate Operators Installation / Commissioning

GET GROUNDED. Renewable Energy System Grounding Basics

GET GROUNDED. Renewable Energy System Grounding Basics GET GROUNDED Renewable Energy System ing Basics by Christopher Freitas ASK TEN RENEWABLE ENERGY INSTALLERS ABOUT SYSTEM GROUNDING and you ll likely get ten different opinions as to what the National Electrical

More information

reflect energy: the ability to do work

reflect energy: the ability to do work reflect Have you ever thought about how much we depend on electricity? Electricity is a form of energy that runs computers, appliances, and radios. Electricity lights our homes, schools, and office buildings.

More information

Battery Power Inverters

Battery Power Inverters Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.4 Important Safety Instructions Please save these instructions.

More information

Selecting & Installing Inverters & Coping with Radio Frequency Emissions

Selecting & Installing Inverters & Coping with Radio Frequency Emissions Selecting & Installing Inverters & Coping with Radio Frequency Emissions The recent large increase in the use of inverters (drives) in the Heating Ventilating & Air Conditioning ( HVAC) industry has brought

More information

Trucking Info: Equipment 7 Factors to Consider When Installing an Inverter

Trucking Info: Equipment 7 Factors to Consider When Installing an Inverter Trucking Info: Equipment 7 Factors to Consider When Installing an Inverter From what size to get to company policies, what fleets need to know when choosing and installing a power inverter. September 2013,

More information

Electrical. Earthing & Bonding. Installation Techniques. Learning Notes MODULE 2.2 UNIT PHASE:2

Electrical. Earthing & Bonding. Installation Techniques. Learning Notes MODULE 2.2 UNIT PHASE:2 Electrical Learning Notes MODULE 2.2 UNIT 2.2.6 Installation Techniques Earthing & Bonding PHASE:2 Table of Contents INTRODUCTION... 3 DEFINITIONS... 4 EARTHING... 5 TYPES OF SYSTEM EARTHING... 10 EQUIPOTENTIAL

More information

OPERATION AND INSTRUCTION MANUAL. EP Series. Battery Chargers and Power Supplies

OPERATION AND INSTRUCTION MANUAL. EP Series. Battery Chargers and Power Supplies OPERATION AND INSTRUCTION MANUAL EP Series Battery Chargers and Power Supplies THIS MANUAL IS PUBLISHED BY EPC CORPORATION AND IS TO BE DISTRIBUTED WITH NEW DEVICES ONLY NO OTHER DISTRIBUTION IS PERMITED

More information

Grounding Systems. Equipment Grounding & Grounded Conductors

Grounding Systems. Equipment Grounding & Grounded Conductors Grounding Systems Equipment Grounding & Grounded Conductors Definitions A Grounded or Earthed system is one that is connected to the earth Grounded Conductor is a conductor that normally carries current

More information

Item L.1 Voltages 1. The consumer voltage must be between +10% and -10% of the nominal national voltage (nnv.)

Item L.1 Voltages 1. The consumer voltage must be between +10% and -10% of the nominal national voltage (nnv.) Village Hydro Specifications Line Distribution Description of Requirement Item L.1 Voltages 1. The consumer voltage must be between +10% and -10% of the nominal national voltage (nnv.) Recommendation 2.

More information

Index. COMPACT domestic gate operator

Index. COMPACT domestic gate operator COMPACT domestic gate operator Index Introduction. 3. General motor layout 4. General site layout 5. Terms and definitions. 6.. Site evaluation. 6. Gate evaluation 7. Removing the lid 8. Placing the gate

More information

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

INDUSTRIAL SLIDING GATE OPERATOR

INDUSTRIAL SLIDING GATE OPERATOR D10 and D10 Turbo Pocket Mechanical Installation Guide TM TM INDUSTRIAL SLIDING GATE OPERATOR 1. Introduction This guide is designed specifically for installers who are familiar with the installation of

More information

PAGE. 20. Connecting an intercom.

PAGE. 20. Connecting an intercom. PAGE C0NTENTS 2. Introduction. 2. Warnings. 2. Specifications. 3. General information. 3. Terms and definitions. 4. Installation. 5. Pedestal mount. 6. Pedestal mount inward swing. 7. Pedestal mount outward

More information

Bunya Solar. Renewable Energy Systems. Remote area power supply system manual

Bunya Solar. Renewable Energy Systems. Remote area power supply system manual Bunya Solar Renewable Energy Systems Mob 0438 120 035 Mob 0428 677 261 10 Page St Moruya NSW 2537 info@bunyasolar.com.au BCSE Accred A0636689 ABN 75 144 538 554 Remote area power supply system manual Welcome

More information

Transmission & Distribution Glossary of Electrical Terms

Transmission & Distribution Glossary of Electrical Terms Transmission & Distribution Glossary of Electrical s Breaker Panel Bushing Circuit Circuit Breaker Conductor Conduit Consumption Current Distribution Electricity (Static vs. Current) Electron Feeder The

More information

The House of Gate Automation

The House of Gate Automation OPTIONAL EXTRA'S SOFT START / SOFT START This is provided as an optional extra and must be requested to fit to a new or old system. It provides an adjustable slow start and slow stop to prevent slambing

More information

THE BATTERY CHARGER OF RON PUGH

THE BATTERY CHARGER OF RON PUGH THE BATTERY CHARGER OF RON PUGH THANKS IS DUE TO RON PUGH WHO HAS KINDLY SHARED THE CONSTRUCTION DETAILS OF HIS VERY SUCCESSFUL BATTERY CHARGER WHICH IS COP=13 WHEN OPERATING AT 24 VOLTS. IF YOU DECIDE

More information

CONVENTIONAL ENGINE CONSTRUCTION

CONVENTIONAL ENGINE CONSTRUCTION CONVENTIONAL ENGINE CONSTRUCTION CYLINDER BLOCKS, HEADS, AND CRANKCASES The cylinder, or the engine block, is the basic foundation of virtually all liquid-cooled engines. The block is a solid casting made

More information

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer

More information

Generator Fire Safety: Generator assemblies should be located outside the building.

Generator Fire Safety: Generator assemblies should be located outside the building. SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building

More information

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...

More information

Modifiable TITAN Horizontal Motors Accessories and Modifications

Modifiable TITAN Horizontal Motors Accessories and Modifications 36. Rotor, Standard And Optional Construction Standard rotor construction of 449, 5000 and 5800 frame TITAN products is typically die-cast aluminum. 720 RPM and slower is typically fabricated aluminum.

More information

Installing the gate post bracket with the cardboard arm template

Installing the gate post bracket with the cardboard arm template ......... Installing the gate post bracket with the cardboard arm template... Installing gate posts brackets and arms for Push-to-Open or Pull-to-Open gates... Connection of Power Source 240Vac or Solar...

More information

Learning Module 10: Loadcenters. 101 Basic Series

Learning Module 10: Loadcenters. 101 Basic Series Learning Module 10: Loadcenters 101 Basic Series What You Will Learn We ll step through each of these topics in detail: What Does a Loadcenter Do? 4 Applications 4 Basic Circuitry and Wiring 5 Residential

More information

DOMESTIC SLIDING GATE OPERATOR

DOMESTIC SLIDING GATE OPERATOR D Turbo Pocket mechanical installation guide TM DOMESTIC SLIDING GATE OPERATOR This guide is designed specifically for installers who are familiar with the installation of standard sliding gate motors,

More information

320A Single Phase URD Meter Loop Installations

320A Single Phase URD Meter Loop Installations 320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal

More information

Chapter 4 Utility Systems Electrical

Chapter 4 Utility Systems Electrical Chapter 4 Utility Systems Electrical Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if

More information

R3R5 quick setup guide ROTARY SWING GATE OPERATOR

R3R5 quick setup guide ROTARY SWING GATE OPERATOR R3R5 quick setup guide TM TM ROTARY SWING GATE OPERATOR 1 REQUIRED TOOLS & EQUIPMENT Check that you have all the tools required. (IM page 1) 3 SITE CONSIDERATIONS Check for the safety and suitability of

More information

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts Chapter 7: DC Motors and Transmissions Electric motors are one of the most common types of actuators found in robotics. Using them effectively will allow your robot to take action based on the direction

More information

Trade of Metal Fabrication. Module 1: Basic Fabrication Unit 15: Electricity Phase 2

Trade of Metal Fabrication. Module 1: Basic Fabrication Unit 15: Electricity Phase 2 Trade of Metal Fabrication Module 1: Basic Fabrication Unit 15: Electricity Phase 2 Table of Contents List of Figures... 5 List of Tables... 6 Document Release History... 7 Module 1 Basic Fabrication...

More information

TONY S TECH REPORT. Basic Training

TONY S TECH REPORT. Basic Training TONY S TECH REPORT (Great Articles! Collect Them All! Trade them with your friends!) Basic Training OK YOU MAGGOTS!! Line up, shut up, and listen good. I don t want any of you gettin killed because you

More information

Motor Protection. Voltage Unbalance & Single-Phasing

Motor Protection. Voltage Unbalance & Single-Phasing For Summary of Suggestions to Protect Three-Phase Motors Against Single-Phasing see the end of this section, page 137. Historically, the causes of motor failure can be attributed to: Overloads 30% Contaminants

More information

Bonds Hoists. Remote Control Operated Ceiling Lamp Lifter. National and International Patents Apply. Instruction for Installation and Operation

Bonds Hoists. Remote Control Operated Ceiling Lamp Lifter. National and International Patents Apply. Instruction for Installation and Operation Bonds Hoists Remote Control Operated Ceiling Lamp Lifter National and International Patents Apply Instruction for Installation and Operation 0044 (0)845 365 1 007 info@bondshoists.com www.bondshoists.com

More information

Electricity 1

Electricity 1 1 Tom Fritts tom@residentialsewage.com 2 Minnesota code?? Why this class?? Troubleshooting Selling the system Know how to calculate usage cost for the homeowner Minimize the surprises You are responsible.

More information

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date: CSDA Best Practice Title: Hi-Cycle Concrete Cutting Equipment Issue No: CSDA-BP-010 : Oct 1, 2010 Revised : Introduction Hi-cycle/high frequency concrete cutting equipment has become more prevalent in

More information

CHAPTER 6.3: CURRENT ELECTRICITY

CHAPTER 6.3: CURRENT ELECTRICITY CHAPTER 6.3: CURRENT ELECTRICITY These components are used in electric circuits. TASK: Draw how you could make this lamp light. Electricity will only flow through a complete circuit. The battery, wires

More information

UPPCO SERVICE MANUAL

UPPCO SERVICE MANUAL Revised 01/2015 Section 6 ELECTRIC SERVICE - GENERAL Page 1 of 10 Section 6 Electric Service - General 6-1 Number of Services and Voltages / Meter... 2 6-2 Energy Conversion Factors... 7 6-3 Lightning

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

EARTHING YOUR QUESTIONS ANSWERED

EARTHING YOUR QUESTIONS ANSWERED 18 EARTHING YOUR QUESTIONS ANSWERED By Geoff Cronshaw What are earthed and unearthed systems? What are the requirements of BS 7671? What are the advantages and disadvantages of the various types of earthing

More information

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power OWNER S MANUAL Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power READ THE ENTIRE MANUAL BEFORE USING THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

Chapter 5 FOUNDATION. 2010, The McGraw-Hill Companies, Inc. 2010, The McGraw-Hill Companies, Inc.

Chapter 5 FOUNDATION. 2010, The McGraw-Hill Companies, Inc. 2010, The McGraw-Hill Companies, Inc. Chapter 5 FOUNDATION 1 FOUNDATION - A rigid foundation is essential for minimum vibration and proper alignment between motor and load. Concrete makes the best foundation, particularly for large motors

More information

Installing the gate post bracket with the cardboard arm template

Installing the gate post bracket with the cardboard arm template ......... Installing the gate post bracket with the cardboard arm template... Installing gate posts brackets and arms for Push-to-Open or Pull-to-Open gates... Connection of Power Source 240Vac or Solar...

More information

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE SOURCE 20V 240V STUD (PER NEC) A customer supplied and installed teaser wire is required from the neutral lug to a 5th terminal mounted on the left side of the meter block between the line and load terminals.

More information

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip

Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Project Number: PAL -10-00063805 Project Name: Urgent Support to the Agriculture and Electricity Sector in the Gaza Strip Bill of Quantities Package # 2 LOT 2: Supply of Electrical Materials The contract

More information

SL100DCx series Sliding gate system Installation guide

SL100DCx series Sliding gate system Installation guide SL100DCx series Sliding gate system Installation guide Application note MAG SL100ACx series is a complete sliding gate automation system. Components in MAG SL100DCx series Gate Automatic System 1 PVC box

More information

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety.

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety. Using Electricity Summary Notes Section Content 1. From the Wall Socket Household appliances. Earth wire and safety. 2. Alternating and Direct Battery and transformer. Current Circuit diagrams. Current

More information

Components for your PV Solar Electric System

Components for your PV Solar Electric System Components for your PV Solar Electric System Here is a brief description of the major components of a Solar Electric System. The components vary depending on whether batteries will be used in your system.

More information

EMC INSTALLATION INFORMATION

EMC INSTALLATION INFORMATION EMC INSTALLATION INFORMATION For: SANYO DENKI Stepper Motors RTA Stepper Drives AUTOMATED MOTION SYSTEMS PTY.LTD. MAILING ADDRESS: P.O.BOX 1240 WANGARA DC W.A. 6947 PHONE: (08) 9309 1896 FAX: (08) 9309

More information

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium

Electric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium Electric Drive Vehicle Infrastructure Training Instructor s Manual National Alternative Fuels Training Consortium Part 4: : Service Panel to Receptacle Overview of Service Panel The role of the service

More information

HPP1 MK6-15A/20A R00 Owners Manual

HPP1 MK6-15A/20A R00 Owners Manual J Wolmarans Page 1 2018/10/23 Page 1 of 7 TABLE OF CONTENTS Page 1 Introduction...2 2 Model...2 3 Safety warnings...2 4 Contents...2 5 Features...2 6 Installation...3 6.1 Mounting the unit:...3 6.2 Connecting

More information

When power interruptions happen.

When power interruptions happen. When power interruptions happen. We know it s never a good time to have your power go out, so we work all year pruning trees and investing in our system to cut down on problems before they start. Outage

More information

Pretest Module 24 Three-phase Service Entrance

Pretest Module 24 Three-phase Service Entrance Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?

More information

An unwritten rule says that when a. Cures for a sick spot welding machine. Figure 1. To test the secondary of the welding machine,

An unwritten rule says that when a. Cures for a sick spot welding machine. Figure 1. To test the secondary of the welding machine, Figure 1 To test the secondary of the welding machine, the power should be turned off. With the electrodes open, the continuity between the top and bottom electrodes should be checked. Cures for a sick

More information

NEC 2011 Code Changes

NEC 2011 Code Changes NEC 2011 Code Changes Articles 280.21-300.50 CHANGES FROM 2008 TO 2011 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1kV III. Connecting Surge Arresters 280.21 Connection

More information

Model 1550 Single Swing Gate Model 1650 Dual Swing Gate

Model 1550 Single Swing Gate Model 1650 Dual Swing Gate Gate Operators, Inc. Model 1550 Single Swing Gate Model 1650 Dual Swing Gate Swing Gate Operator CONTENTS Safety Precautions... 2 Applications... 3 Pre-Installation Checklist... 4 Parts Identification...

More information

environment briefing02

environment briefing02 The Voice of the Networks environment briefing02 transporting electricity Overhead Lines or Underground Cables Introduction The Electricity Act 1989 requires electricity companies both to maintain an efficient

More information

CLIF NOTES SERIES (Competent Leveraging of Information and Facts) ELECTRICAL

CLIF NOTES SERIES (Competent Leveraging of Information and Facts) ELECTRICAL CLIF NOTES SERIES (Competent Leveraging of Information and Facts) ELECTRICAL What basic information do you need to know about electrical systems in buildings and why? The Capital Partners Electrical CLIF

More information

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001 CLP POWER HONG KONG LIMITED SUPPLY March 2001 ADVISORY SERVICE Advice concerning matters relating to the supply of electricity may be obtained free of charge from the Company. OTHER COMPANY PUBLICATIONS

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

Bonds: Chandelier Company

Bonds: Chandelier Company Bonds: Chandelier Company Remote Control Operated Ceiling Lamp Lifter National and International Patents Apply Instruction for Installation and Operation 0044 (0)845 365 1 007 info@thechandeliercompany.com

More information

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012 100V to 1000V DC 100A to 5000A DC SERIES 50 MODELS 506 & 5012 6 Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems Applications: Electrocoating Ion Nitriding Magnet

More information

TECHNICAL SPECIFICATIONS for. Telecommunication Battery Backup Systems (TBS)

TECHNICAL SPECIFICATIONS for. Telecommunication Battery Backup Systems (TBS) TECHNICAL SPECIFICATIONS for Single Phase, Outdoor, 400 Watt to 1600 Watt Uninterruptible Power System and Power Conditioner NEMA 3R & NEMA 4 Cabinet Telecommunication Battery Backup Systems (TBS) TBS6507A

More information

400/230 Volt 60Hz UPS Power

400/230 Volt 60Hz UPS Power olt 60Hz Power Using ual Voltage standby generation and in one Nothing protects quite like Piller www.piller.com Contents 1 Abstract...3 2 Introduction...4 3 Alternative Power istribution...6 4 Integrating

More information

Generator Termination Bus-bar Arrangement - Design requirements: Utility Perspective

Generator Termination Bus-bar Arrangement - Design requirements: Utility Perspective Generator Termination Bus-bar Arrangement - Design requirements: Utility Perspective D. K. Chaturvedi (NTPC) Harshvardhan Senghani (NTPC) K Venugopal (CS Electric) This paper appraise user on the termination

More information

5. High voltage warning labels should be placed on all cabinet doors and terminal covers enclosing equipment operating at above 50 volts.

5. High voltage warning labels should be placed on all cabinet doors and terminal covers enclosing equipment operating at above 50 volts. Village hydro specifications Electrical components E1. Labels and notices Requirement 1. All electrical components must carry labels describing their function. This applies particularly to switches and

More information

CHAPTER V RESIDENTIAL WIRING

CHAPTER V RESIDENTIAL WIRING CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this

More information

Dankoff LCB Solar Pump & Fan Controller. INSTRUCTIONS For INSTALLATION and OPERATION

Dankoff LCB Solar Pump & Fan Controller. INSTRUCTIONS For INSTALLATION and OPERATION Dankoff LCB Solar Pump & Fan Controller INSTRUCTIONS For INSTALLATION and OPERATION Model DL-8B Model DL-16B Model DL-10B CUSTOM Models (8 amp, 12/24V) Item ISS-11065 (16 amp, 12/24V) Item ISS-11066 (10

More information

Installation Manual. For. Hi-Speed Alumavator / Platinum Vertical Boat Lifts

Installation Manual. For. Hi-Speed Alumavator / Platinum Vertical Boat Lifts Installation Manual For Hi-Speed Alumavator / Platinum Vertical Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all persons that may operate

More information

Grounding Of Standby & Emergency Power Systems

Grounding Of Standby & Emergency Power Systems July / August 2007 ELECTRICAL LINE 53 Grounding Of Standby & Emergency Power Systems By Andrew Cochran Power continuity is essential in many industrial and commercial installations where a trip out due

More information

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI SERVICE REQUIREMENTS This section discusses the requirements for establishing electric service to new residential subdivisions in Palo Alto. Subdivisions are normally constructed on dedicated

More information

TRANSMISSION SYSTEMS

TRANSMISSION SYSTEMS TRANSMISSION SYSTEMS Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution of electric

More information

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection White paper SACE Tmax XT Circuit-Breaker Terminals and Connection Circuit-Breaker Terminals and Connections Index Introduction... 2 1. Components used for wiring... 3 1.1. Electrical...3 1.2. Flexibility

More information

Installation and Construction Notes for EVSE4

Installation and Construction Notes for EVSE4 Installation and Construction Notes for EVSE4 You need to read and understand this if you want to build an EVSE that will be safe and need to pass a building inspectors review. Before beginning this process

More information

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc. Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution

More information

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Unarmored Variable Frequency Drive (VFD) Cable Termination Guide Be Certain with Belden A Step-by-Step Look at the Connection/Termination of Unarmored VFD Cables Terminating Unarmored Variable Frequency

More information

UNDERSTANDING ELECTRICAL EQUIPMENT AND CONDITIONS OF INCREASED RISK

UNDERSTANDING ELECTRICAL EQUIPMENT AND CONDITIONS OF INCREASED RISK UNDERSTANDING ELECTRICAL EQUIPMENT AND CONDITIONS OF INCREASED RISK 5 October 2017 John A. Weber Principal Electrical Engineer, Hartford Steam Boiler Inspection and Insurance Company Electrical Power Transmission

More information

Hunter Automatics HA-8. Installation Manual

Hunter Automatics HA-8. Installation Manual Hunter Automatics HA-8 Installation Manual WARNING TO REDUCE RISK OF INJURY 1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY. FAILURE TO DO SO MAY RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE

More information

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts Installation Manual For High Speed Alumavator and Platinum 10 and 23 Degree Elevator Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all

More information

Part C: Electronics Cooling Methods in Industry

Part C: Electronics Cooling Methods in Industry Part C: Electronics Cooling Methods in Industry Indicative Contents Heat Sinks Heat Pipes Heat Pipes in Electronics Cooling (1) Heat Pipes in Electronics Cooling (2) Thermoelectric Cooling Immersion Cooling

More information

Pretest Module 29 High Voltage Unit 1

Pretest Module 29 High Voltage Unit 1 Pretest Module 29 High Voltage Unit 1 1. Is a person qualified to work on high-voltage installations when this module is completed? 2. What is the code definition of high-voltage? 3. What is the IEEE definition

More information

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL SAVE THIS MANUAL You will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance procedures, parts

More information

SLIDING GATE OPENER USER MANUAL

SLIDING GATE OPENER USER MANUAL is600 / is900solar24 SLIDING GATE OPENER USER MANUAL Bluetooth charge monitoring app INDEX 1.1 GENERAL SAFETY PRECAUTION 1.2 KIT CONTENTS.. P.1 P.2 1.3 DIMENSION... P.3 1.4 TECHNICAL FEATURES P.4 1.5 INSTALLATION

More information

Chapter 21 Practical Electricity

Chapter 21 Practical Electricity Chapter 21 Practical Electricity (A) Electrical Power 1. State four applications of the heating effect of electricity. Home: o Used in electric kettles o Used in electric irons o Used in water heaters

More information

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL SAVE THIS MANUAL You will need the manual for the safety warnings and precautions, assembly instructions, operating and maintenance procedures, parts

More information

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W Instruction Manual Introduction The AIMS Power 5000 Watt series inverters are the most advanced line of mobile DC to AC power

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours Candidate Code No. IT 32 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MM-338 FOOTBALL SCOREBOARD OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will give

More information

APOLLO Gate Operators, Inc.

APOLLO Gate Operators, Inc. APOLLO Gate Operators, Inc. Model BA12 12 VOLT DC BARRIER ARM OPERATOR INSTALLATION MANUAL 0707 CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 3 Applications... 4 Pre-Installation Checklist... 5 Operator Installation...

More information

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts Installation Manual For Alumavator and Platinum Vertical Installation Elevator Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all persons

More information

Buying Your First Home EV Charger

Buying Your First Home EV Charger Buying Your First Home EV Charger Written By: Feitan INTRODUCTION It may surprise EV newbies to learn that an electric car s charger is found on board the vehicle. It s the equipment buried in the guts

More information

How to: Test & Evaluate Motors in Your Application

How to: Test & Evaluate Motors in Your Application How to: Test & Evaluate Motors in Your Application Table of Contents 1 INTRODUCTION... 1 2 UNDERSTANDING THE APPLICATION INPUT... 1 2.1 Input Power... 2 2.2 Load & Speed... 3 2.2.1 Starting Torque... 3

More information

Electrical Systems. Introduction

Electrical Systems. Introduction Electrical Systems Figure 1. Major Components of the Car s Electrical System Introduction Electricity is used in nearly all systems of the automobile (Figure 1). It is much easier to understand what electricity

More information

DIY 15 Amp Portable Generator Transfer Switch

DIY 15 Amp Portable Generator Transfer Switch DIY 15 Amp Portable Generator Transfer Switch ------------------------------------------------------------------------------------------------- WARNING You MUST read these warnings before proceeding. This

More information

Porte 150 Users Manual Swing Gate Opener 24V DC

Porte 150 Users Manual Swing Gate Opener 24V DC Porte 150 Users Manual Swing Gate Opener 24V DC for residential use only Signal Light Push-button Control Box 14 Contents 1. Important Safety Information 2. Product Description and Application 2.1 Application

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 250 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 50 250 V ow profile casing (21 x 30 mm cross-section)

More information

VANTAGE Mechanical Installation Manual

VANTAGE Mechanical Installation Manual VANTAGE Mechanical Installation Manual Centurion Systems (Pty) Ltd page 1 COMPANY PROFILE Company Profile 1986 1990 1995 1999 Today In-house R&D development team Manufacture to international quality standard

More information

THE FORGOTTEN BATTERY, LEAD ACID.

THE FORGOTTEN BATTERY, LEAD ACID. CASE STUDY Our client farms which specialises in slow grown Longhorn Beef. Site owner identified that is is far more commercially viable to sell to the public. The challenge following a grid connection

More information