DIY 15 Amp Portable Generator Transfer Switch
|
|
- Elinor Griffith
- 6 years ago
- Views:
Transcription
1 DIY 15 Amp Portable Generator Transfer Switch WARNING You MUST read these warnings before proceeding. This is not a task for the electrically uneducated or inexperienced. Electricity can and does KILL. It is important to keep in mind that electricity can kill, maim and damage through electrical shock and through such things as fire via arc-induced burning and high resistance connections. It is also very important to note that if you incorrectly install transfer equipment, or fail to install transfer equipment, you can easily harm or kill utility workers and neighbors outside of your residence through back feeding. If you are not comfortable or technically qualified for this task, spend the few extra dollars to purchase purpose built equipment and pay a professional to install it. While proper installation of any electrical components is a major life safety issue, improper or poor installation can also cause extensive and quite expensive damage to equipment. You must be familiar with national codes, i.e. NFPA 70 National Electric Code and ICC International Residential/Building Codes, and with any local and/or utility restrictions, codes or amended adoptions. Yes, that s right, some utility companies require notification, inspection and adherence to special utility requirements for installation of a standby generator (a portable wired into any of the residence s circuits is considered a standby generator.) The information provided here is for INFORMATIONAL PURPOSES ONLY and should not be considered or inferred as instructional in nature. Basic electrical knowledge and installation steps were omitted
2 TRANSFER SWITCH BASICS What is a transfer switch as used with a standby generator and your home? Well, the
3 simple answer is that it isolates the generator from the home s electric utility service and vice versa. Without a transfer switch, the only way to tie a generator into your home s electrical system is to perform the very dangerous and likely illegal act of back feeding. Back feeding is done by connecting the output of your generator to your home s electrical system, typically by plugging into a receptacle. This is dangerous for several reasons. The first reason that this is unacceptable is that, with a large enough generator, can likely overload the circuit that you are back feeding through resulting in damage, fire or injury. Another reason that one must be mindful of the dangers of back feeding is the simple fact that you can energize not only your entire house, but your neighborhood and even primary service lines. It is important to note that when you back feed, the same transformer that reduces line voltages to your household voltages can work in reverse. That is, your 120 volts put out by your generator can be stepped up to line voltage back feeding through a transformer. You could imagine how dangerous this can be for utility workers repairing downed lines, damaged equipment, etc. The basic function of a transfer switch in a standby generator system is to isolate two separate feed sources for a load(s) from each other, preventing any chance of one power system feeding the other and vice versa. The following graphic illustrates a basic schematic of a single transfer switch. The illustrated switch is a single pole, double throw (SPDT) type. A common example of a SPDT switch is a three-way switch found in the home. As drawn, the load/appliance is connected to the electric service of the building and/or residence. The generator supply in this example is isolated from the load and the electric service. When the transfer switch is actuated/switched, the connection between the electric service/line power will break and then the switch will make the connection between the load and the generator. Note the terms make and break for these are important. It is possible to have two different types of SPDT switches: make before break and break before make. A make before break switch will actually have a brief period of time during switching where both the line power and the generator will be connected. The break before make switch, the common type, theoretically should never allow the connection of the two power sources. Obviously, this is the type of switch that we need. The three-way switch mentioned earlier is typically this type of SPDT switch.
4 There are several companies that manufacture and sell preassembled transfer switches, basically, off-the-shelf solutions. Two of these companies are GenTran and Reliance. For what these switches are, sets of SPDT switches and some push button breakers (for the basic manual options), I have yet to meet anyone that thought these were a bargain. Based on my needs and what is available on the market, I opted to design and install a much more economical, custom matched to my needs and just as safe for property and life transfer switch system. TRANSFER SWITCH DESIGN & INSTALLATION
5 The above illustration captures my transfer switch design. Some important safety oriented characteristics to note regarding this design: Note that all boxes, grounded receptacles and grounded switches are bonded to the generator s ground and in turn bonded to the ground bus at the electric service panel for my house. The neutral from the generator is bonded to the neutral bus of the service panel which, in turn, is bonded to the ground bus of the service panel. Note: My generator, Honda Eu2000i, does not have a neutral bonded to ground at its feed points. In this particular example, you do NOT want to bond the neutral and ground at the generator, Honda Eu2000i, if you are bonding the neutral and ground buses at the service panel. Some generators come from the factory with a neutral to ground bond, but that is not so in my case. In my example, if I were to bond the neutral and ground at my generator and have the neutral grounded at the panel, I now have two different paths for return current to flow to my generator. Return current on the ground will create voltage on the ground and that is NOT good. For now, you theoretically have an energized ground and this is both a life safety and property concern. All circuits being dual served are 15 amp in size in the main service panel. While the generator has 20 amp circuit protection, this is too much for my home s 15 amp branch circuit wiring. So, I would be able to overload a 15 amp branch circuit with 19.9 amps and never trip the generator circuit protection out. Also, keep in mind that 15.1 amps will not instantaneously trip a 15 amp breaker. As a matter of fact, 15 amps on a 15 amp protected circuit could take minutes or longer before tripping. It is also important to note that a 20 amp breaker will not trip as fast with higher currents as what a 15 amp breaker would. All of these concerns/issues could be major fire safety hazards. To prevent any issues, each transfer switch s generator side line is protected by a 15 amp breaker (All of the 15 amp circuits utilize 14/2 W/ Ground wiring). The feed cable (12/2 W/ Ground) from the L5-20R receptacle (where the generator is hooked up outside) and the receptacle itself are sized to accommodate the 20 amp protected circuit provided by the generator as is the utility receptacle. The transfer switches are 20 Amp models with Heavy Duty Contacts to prevent welded or sticking contacts in order to meet the break before make requirement as mentioned above. The basic flow of the system is as follows:
6 Generator > Service Cable > Twist-Lock Receptacle > Split to Utility Outlet & Generator 2 Breaker, 4 Circuit Load Center > Transfer Switch > Load (E.g. Appliance) The materials list is as follows: Outdoor Receptacle (See Part 2 below.) L5-20I Flanged Insert Receptacle Outdoor, Deep Receptacle Box Hubbell Flanged Insert Outdoor Receptacle Box Cover Vinyl Siding J-Block Generator Load Center Cutler-Hammer 2 Breaker, 4 Circuit Load Center (Cutler-Hammer to match existing service panel) Cutler-Hammer Twin 15/15 Amp BR Breakers Utility Outlet Single Metal Box 20 Amp 120V Duplex Receptacle Duplex Receptacle Cover Transfer Switches 20 Amp Heavy Duty Three-Way SPDT Switches Double Metal Boxes Double Switch Covers Miscellaneous: Wiring, Conduit, Etc. 12/2 W/ Ground 14/2 W/ Ground 3/4 EMT Conduit 3/4 Conduit Clamps 3/4 Conduit Setscrew Connectors Wire Nuts & Electrical Tape
7 At a minimum, your design, layout and installation must comply with the current revision of the National Electric Code. In my case, the current revision that must be complied with is NFPA 70 National Electric Code Remember, your local jurisdiction may require drawings, permitting, inspections and requirements in excess of code requirements. Some of the items of importance from the National Electric Code that apply to this installation are as follows: Grounding Requirements - Article (Previously discussed.) Article 100 Definitions Separately Derived System. A premises wiring system whose power is derived from a source of electric energy or equipment other than a service. Such systems have no direct electrical connection, including a solidly connected grounded circuit conductor, to supply conductors originating in another system. (My system is a non-separately derived system. This definition later determines various requirements for installation.) Article Enclosures for Switches or Overcurrent Devices Enclosures for switches or overcurrent devices shall not be used as junction boxes, auxiliary gutters, or raceways for conductors feeding through or tapping off to other switches or overcurrent devices, unless adequate space for this purpose is provided. The conductors shall not fill the wiring space at any cross section to more than 40 percent of the cross-sectional area of the space, and the conductors, splices, and taps shall not fill the wiring space at any cross section to more than 75 percent of the crosssectional area of that space. (This Article covers the use of wire nuts inside of a service panel. It is OK given compliance with this Article is maintained.) Article 702 Optional Standby Systems Scope: The provisions of this article apply to the installation and operation of optional standby systems. The systems covered by this article consist of those that are permanently installed in their entirety, including prime movers, and those that are arranged for a connection to a premises wiring system from a portable alternate power supply. (This Article and its various sections dictate the actual design, installation and integration of a standby power system, i.e. generator, into your existing electrical distribution system.) Following the design schematic above, installation and integration was actually very rudimentary and easy. One important safety note here is that you should NEVER work inside of a hot /energized panel. It is best if you can not only de-energize a service
8 panel that you are working in but lock out the main disconnect as well! All it takes is a mistake or inattention lasting only a few milliseconds to permanently change your life! My main service panel for the house
9 Installation of the transfer switches. Note that I have number markers on the wires to assist in keeping the installation straight as well as troubleshooting if ever required
10
11 It is important to keep your routing clean and out of the way
12
13
14 The finished product. Note I have a copy of the basic schematic in an envelope at the transfer switch
15
16
17
18 Outside hookup to the standby generator transfer system
19
20 The parts that you see here are as follows: Hubbell 2315 Flanged Insert This is the receptacle that is basically a recessed male plug. Hubbell 2313 Equivalent L5-20C Connector This is the receptacle end of the patch cord. Hubbell WP-2 Flanged Cover Plate This is the spring-loaded flip cover for the flanged insert. Note: The above listed parts, if purchased through a catalog supply house can easily total more than $140. However, in this instance, Ebay is your friend! I picked up all three pieces above for approximately $40 shipped.
21 The Honda Eu2000i and patch cord that will power it all
22
23 IMPORTANT NOTE: It is very important that you utilize the proper flanged inlet and female connector for the hookup on the exterior of dwelling and the patch cord respectively. The inlet and
24 connector are not readily found at Lowe s, Home Depot or similar Big Box store. It is easy to want to cut corners and use a standard receptacle and plug. However, this is very, very dangerous. If you use a standard receptacle and plug, you will end up with what is labeled as a suicide plug or suicide cord. That is, you will wind up with a patch cord that has two male plugs rather than one female connector and one male plug. In turn, there is potential for one set of the exposed prongs of the plugs to be energized while operating the generator if installed as detailed in this post. The National Electric Code has the following to say regarding connection of attachment plugs Article (B) Connection of Attachment Plugs Attachment plugs shall be installed so that their prongs, blades, or pins are not energized unless inserted into an energized receptacle or cord connectors. No receptacle shall be installed so as to require the insertion of an energized attachment plug as its source of supply.
25 So, this type of connection is illegal and has the potential to kill you
26 (Thanks Millerized for helping to keep me safe!) In addition to everything mentioned above, I authored a set of startup instructions for the system in the event that I am not home for any other adult to utilize. These are stored in an easy to access location on our main floor. Stay safe and remember, when in doubt, call a professional!
90.2 Scope. The installation of electrical conductors, equipment and raceways for:
NEC Generator Primer Rules on the installation of generators and transfer switches 1 90.2 Scope The installation of electrical conductors, equipment and raceways for: public and private premises Conductors
More informationNEC REQUIREMENTS FOR GENERATORS
PROFESSIONAL DEVELOPMENT SEMINAR SERIES NEC REQUIREMENTS FOR GENERATORS (Based on NEC 2005 with limited 2008 commentary) AIA certified Continuing Education Units (CEU) Available GPS-140 National Electric
More information9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC
2011 NEC Significant Changes Courtesy of NJATC Courtesy of NFPA Presented By: Michael J. Johnston Executive Director of Standards and Safety, NECA Objectives Review significant revisions in the 2011 NEC
More informationElectric Drive Vehicle Infrastructure Training. Instructor s Manual. National Alternative Fuels Training Consortium
Electric Drive Vehicle Infrastructure Training Instructor s Manual National Alternative Fuels Training Consortium Part 4: : Service Panel to Receptacle Overview of Service Panel The role of the service
More informationENTRANCE EQUIPMENT ER D PAGE 1 OF 5
PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument
More informationPermit for Charging Equipment Installation Electric Vehicle Supply Equipment (EVSE)
Permit for Charging Equipment Installation Electric Vehicle Supply Equipment (EVSE) Town of Lake George, New York Compliance with the following permit will allow the installation and operation of electric
More informationWIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST
WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST Use & Identification of Grounded and Grounding Conductors YES NO N/A Grounded conductors are identifiable and distinguishable from all other conductors.
More informationThis is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS (ELEC) This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
More informationLoad Side PV Connections
Perspectives on PV Load Side PV Connections 705.12(D) in the 2014 NEC by John Wiles Through the exceptional efforts of the members of NFPA NEC Code-Making Panel 4 working with the proposals and comments
More informationSUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL
SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
More information9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.
Chapter 3 TRANSMISSION SYSTEMS 1 Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS MANUAL TRANSFER SWITCHES FROM 0 Residential Wattage Requirements Appliance Running Watts Add watts for starting Furnace blower, gas or fuel 1/8 hp 300 500 1/8 hp
More informationSINGLE PHASE WIRING SPECIFICATIONS
SINGLE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425
More informationOWNER S MANUAL AND INSTALLATION INSTRUCTIONS
EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR
More informationSupply-Side PV Connections
Perspectives on PV Supply-Side PV Connections by John Wiles Plan reviewers and inspectors throughout the country are seeing increasing numbers of supply-side connected utility interactive photovoltaic
More informationTemporarily Approved Solar Photovoltaic System Electrical Schematics
March 20, 2019 Page 1 of 10 Temporarily Approved Solar Photovoltaic System Electrical Schematics This document is intended as a temporary interpretation of approved solar photovoltaic electrical schematics
More informationGenerator Fire Safety: Generator assemblies should be located outside the building.
SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationCHAPTER V RESIDENTIAL WIRING
CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this
More informationFACT SHEET Standard: Electrical Safety
What is a Ground Fault Circuit Interrupter? FACT SHEET The ground-fault circuit interrupter, or GFCI, is a fast-acting circuit breaker designed to shut off electric power in the event of a ground-fault
More informationCHAPTER 10 ELECTRICAL. Notes:
CHAPTER 10 ELECTRICAL 1001.0 General Requirements. Electrical wiring and equipment shall comply with the requirements of NFPA 70, National Electrical Code (NEC), or local ordinances. 1002.0 Solar Photovoltaic
More informationInstallation and Construction Notes for EVSE4
Installation and Construction Notes for EVSE4 You need to read and understand this if you want to build an EVSE that will be safe and need to pass a building inspectors review. Before beginning this process
More informationTHREE PHASE WIRING SPECIFICATIONS
THREE PHASE WIRING SPECIFICATIONS 1-866-MEC-ELEC (1-866-632-3532) Office Locations: Hondo Office 237 Hwy 173 N Hondo, TX 78661-0370 Fax 830.426.3335 Dilley Office 1718 W. FM 117 Dilley, TX 78017 Fax 830.965.1425
More informationElectrical Equipment and Terminology
Youth Explore Trades Skills Description Understanding the language of the electrical trade and knowing what electrical equipment is named and its purpose are very important. Anyone who is exposed to a
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationCorrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections
Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections One-Line / Riser Diagrams Drawings are not reviewed prior to submission. Because of
More informationMetering and Service Installation:
Table of Contents 1. Metering Installation Requirements, General... 1 2. Type of Service... 2 3. Definitions... 2 4. Who Provides Metering Equipment?... 2 5. Establishment of Service... 2 6. Meter Access...
More informationTEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES
INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I am inspecting a building addition. They have a 480V to
More informationArc Fault Circuit Interrupter (AFCI) FACT SHEET
Arc Fault Circuit Interrupter (AFCI) FACT SHEET THE AFCI The AFCI is an arc fault circuit interrupter. AFCIs are newly-developed electrical devices designed to protect against fires caused by arcing faults
More informationPhotovoltaic Solar Plan Review
PAIGE B. VAUGHAN, CBO Director of Building and Safety Phone (310) 605-5509 Fax Line (310) 605-5598 E-mail:lbutler@comptoncity.org Building & Safety Department Photovoltaic Solar Plan Review Plan Check
More informationEasy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH
STANDBY POWER FURNACE SWITCH Easy/Tran TF Congratulations on your purchase of the Reliance Controls Easy/Tran TF furnace transfer switch. Reliance has been manufacturing transfer switches and equipment
More informationTONY S TECH REPORT. Basic Training
TONY S TECH REPORT (Great Articles! Collect Them All! Trade them with your friends!) Basic Training OK YOU MAGGOTS!! Line up, shut up, and listen good. I don t want any of you gettin killed because you
More informationManaging Electric Vehicle Supply Equipment (EVSE) Installations
Managing Electric Vehicle Supply Equipment (EVSE) Installations Introduction to Electric Vehicle EVSE Electric vehicles create a need to build an infrastructure that will supply the added load of charging.
More informationTRANSMISSION SYSTEMS
TRANSMISSION SYSTEMS Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution of electric
More informationINDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE
INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23 GUIDELINES FOR WORKING WITH LIGHTING SYSTEMS AND OTHER ELECTRICAL EQUIPMENT All electrical systems and electrically energized equipment
More informationOCEAN COUNTY ARES EMERGENCY GENERATOR USE By WX2NJ. The following was taken from September and October Ocean County ARES Newsletters in 2012:
The following was taken from September and October Ocean County ARES Newsletters in 2012: I recently purchased a used 9KW dual-fuel (gasoline/propane) generator from a gentleman in Atlantic County, who
More informationOvercurrent Protection (2014 NEC) (Homestudy)
Overcurrent Protection (2014 NEC) (Homestudy) Oregon Electrical License The key sections of Article 240 will be discussed. Overcurrent protection for panelboards, appliances, motors, motor compressors,
More information2016 Photovoltaic Solar System Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE
More informationELECTRICAL CONSISTENCY MEETING
ELECTRICAL CONSISTENCY MEETING Date: 10/14/2015 Our Goal is FOR ALL STAKEHOLDERS TO HAVE A SUCCESSFUL PROJECT with us and that together we keep people and structures safe and economically viable to serve
More informationCode Compliance. Perspectives on PV. Back to the Grid, Designing PV Systems for
Perspectives on PV A series of articles on photovoltaic (PV) power systems and the National Electrical Code by John Wiles Back to the Grid, Designing PV Systems for Code Compliance 20 IAEI NEWS January.February
More informationSOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST
SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST The following checklist is an outline of the general requirements found in the 1999 National Electrical Code (NEC) Article 690 for Photovoltaic (PV) Power
More information1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".
SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,
More informationUNDERGROUND SERVICES - SECONDARY
UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service
More informationOptimizing Emergency Power Systems for Health Care Applications
2018 Annual Conference Optimizing Emergency Power Systems for Health Care Applications aka: Using the latest code changes to improve system reliability and maybe even save some $$$... Overview Michigan
More informationDefinitions of and have been revised. a. automatic b. nonautomatic c. none of the above d. both a and b
www.garyklinka.com Page 1 of 12 Instructions: Fee $25 1. Print these pages. 2. Circle the correct answers and transfer them to the answer sheet. 3. Page down to the last page for the verification forms
More informationChange the and later A/C & Heat system on the Discovery coach With the multi-zone coleman mach thermostat
Change the 2001.5 and later A/C & Heat system on the Discovery coach With the multi-zone coleman mach thermostat This schematic and wiring diagram is to be used only for single stage heating and single
More informationELECTRICAL. 60 Minutes
ELECTRICAL 60 Minutes AGENDA Electrical definitions Electrical shocks, burns and secondary injuries Electrical hazards in the workplace Safety devices and prevention steps Do s and Don ts INTRODUCTORY
More informationOvercurrent Protection According to the 2011 NEC
Overcurrent Protection According to the 2011 NEC Utah Electrical License This course will cover overcurrent protection according to the 2011 NEC. The key sections of Article 240 will be discussed. Overcurrent
More informationUNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation
Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationUPPCO SERVICE MANUAL
Revised 01/2015 Section 6 ELECTRIC SERVICE - GENERAL Page 1 of 10 Section 6 Electric Service - General 6-1 Number of Services and Voltages / Meter... 2 6-2 Energy Conversion Factors... 7 6-3 Lightning
More informationDESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5
DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this
More informationService Entrance Methods
Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I recently installed a 45-KVA transformer, 480-volt primary
More informationPHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST
PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST The following checklist is an outline of the general requirements found in the 2005 National Electrical Code (NEC) Article 690 for Photovoltaic
More informationInstallation and Operating Instructions SWITCHED NEUTRAL KIT MODEL SNK
Installation and Operating Instructions SWITCHED NEUTRAL KIT MODEL SNK Warning: The Gen/Tran Switched Neutral Kit should be installed by a professional electrician familiar with electrical wiring and codes,
More informationSpring Test 10 due 05/11/2013
Spring Test 10 due 05/11/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. When installed in an agricultural building that houses livestock
More informationTransfer Switch TS-50. Owner s Manual
Transfer Switch TS-50 Owner s Manual Table of Contents Introduction 2 Installation 2 Operational Testing 7 Troubleshooting 7 Hi-Pot Testing 8 Generator Note 9 Medical Appliances 10 Caution 10 Disclaimer
More informationSpring Test 7 due 05/03/2013
Spring Test 7 due 05/03/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A raceway contains two 3-phase, 3-wire circuits that supply 38 ampere continuous
More information2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE
2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying
More informationCHAPTER 10 ELECTRICAL
1001.0 General Requirements. 1001.1 Electrical Wiring and Equipment. Electrical wiring and equipment shall comply with the requirements of NFPA 70, National Electrical Code (NEC), or local ordinances.
More informationElectrical Tech Note 106
Electrical Tech Note 106 Biosystems & Agricultural Engineering Department Michigan State University Master Exam Study Guide and Sample Questions 1 Based on the 2014 NEC, Part 8 of PA 230, PA 407, and the
More informationEV Charging Station Submittal Requirements
EV Charging Station Submittal Requirements To obtain a permit for an Electric Vehicle Charging Station, please provide the following: Plan and details of the charging system installation o Print applicable
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these
More informationAn average of one worker is electrocuted on the job every day There are four main types of electrical injuries:
Electrical Safety Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock) Electrical shock
More informationENGINEERING SPECIFICATION
December 206 ENGINEERING SPECIFICATION No. of 6 DATE: 2-9-6 CATEGORY SUBJECT TABLE OF CONTENTS. Overview... 2 2. General Requirements for Service... 3 3. Definitions... 3 4. Abbreviations... 5 5. References
More information2014 NEC Changes (Homestudy)
2014 NEC Changes (Homestudy) Idaho Electrical License This course will review the most important National Electrical Code changes from the 2014 NEC. Changes in Articles 100 - Chapter 9 will be covered.
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationUnderstanding Electrical Terms
Understanding Electrical Terms Complimentary brochure from Understanding Electrical Terms In today s computer-intensive work environments, a critical issue is clean, reliable power. Powerlite is the industry
More informationSection 6 Electric Metering: Residential
Section 6 Electric Metering: Residential 6.1. Scope This section provides specific information for residential metering that is not covered by the basic requirements in Section 5, Electric Metering: General.
More informationTen Deadly Conditions to Check for in Your Boat's Electrical System - Part 2
Ten Deadly Conditions to Check for in Your Boat's Electrical System - Part 2 In the September newsletter, 1 through 5 of the ten deadly conditions were presented (link to previous article). Deadly conditions
More informationA. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.
SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationUtility Distribution Systems Installation, Operation, and Maintenance Manual
Utility Distribution Systems Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately
More informationFig. 1. Sample calculation for determining the proper conductor size needed to serve a motor controller and avoid voltage drop problems.
Power to the Pump By Mike Holt, NEC Consultant Why some fire pump requirements are "backward" One of the principal NEC requirements for circuit protection is that you shut down the equipment rather than
More informationCity of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax
City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA 94596 (925) 943-5834 phone (925) 256-3500 fax Issued September 30, 2017 Policy Bulletin No. PB-72 Background Residential
More informationOwner's/Installation Manual
Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH
More informationLT Charging Cart for Laptops
Built with Anthro-DNA LT Charging Cart for Laptops Owners Manual This unit has been tested to Underwriters Laboratories U.S. and Canadian (Bi-National) Standard for Safety of Informational Technology Equipment,
More informationITS-50R TRANSFER SWITCH OWNER S MANUAL
ITS-50R OWNER S MANUAL IOTA Engineering Transfer Switches provide automatic power switching between two or three separate 120/240 volt AC input sources, including powercords, onboard generators, onboard
More informationMike Holt s Illustrated Guide to SOLAR PV SYSTEMS
Mike Holt s Illustrated Guide to Directory, Identification, Label, Marking, Plaque, and Sign Requirements for SOLAR PV SYSTEMS Extracted From Mike Holt s Illustrated Guide to Understanding NEC Requirements
More informationBP OIL -- TOLEDO REFINERY
BP OIL -- TOLEDO REFINERY Document Type: Procedure Effective Date: August 31, 2017 Owner: Dane P. Clark Refinery Wide Electrical Distribution System Switching and Isolation Auth. By: Rick J. Chmelovski
More informationINSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL
Photovoltaic (PV) Residential Page 1 of 10 Revision Date: 07/18/2018 INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL INSPECTION CODE: 703 SCOPE: RESIDENTIAL APPLICABLE CODES: 2016 CBC, CRC, CPC,
More informationLine Gard. Underwriters Laboratories (UL) Applicable Code Notation
Underwriters Laboratories (UL) UL 50E Enclosures for Electrical Equipment, Environmental Considerations 1.1 This standard applies to enclosures for electrical equipment intended to be installed and used
More informationPORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0
PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0 MM September 21, 2012 TABLE OF CONTENTS Section Number DANGER INTRODUCTION AND TECHNICAL SPECIFICATIONS 1 CONTROL AND METERING DESCRIPTION 2 OPERATION
More informationChapter 5. Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI)
Chapter 5 Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI) Imagine That Engineering Inc. has adopted this program for equipment
More informationWARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES
FILE 29-900 Instructions for Combination Bypass Isolation and Transfer Switches 100-1000 Amps APPLICATION The Cutler-Hammer combination Bypass Isolation and Transfer Switches are listed under Underwriters
More informationPrecision Power Center INSTALLATION, OPERATION, & MAINTENANCE MANUAL
POWER CONVERSION/DISTRIBUTION Precision Power Center INSTALLATION, OPERATION, & MAINTENANCE MANUAL 3 Phase 15 kva - 225 kva 50 & 60 Hz TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................................1
More informationElegance Electrician s Installation Guide
Elegance Electrician s Installation Guide CentraLite Systems, Inc. 6420 Wall St. Mobile, AL 36695 Phone: 877-466-5483 Fax: 251-607-9119 2003-2005 CentraLite Systems, Inc. Revised 10/20/2005 ELECTRICIAN
More informationA. This section includes unit capacitors for power factor correction.
PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not
More information2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00
DO YOU KNOW THE FACTS ABOUT SINGLE-POLE INTERRUPTING RATINGS? YOU MAY BE IN TROUBLE! Typical plant electrical systems use three-phase distribution schemes. As an industry practice, short-circuit calculations
More informationMaintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C
C Mobile Communications 13 AMPERE POWER SUPPLY 19A704647P1-P3 CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER
More informationChapter 4 Utility Systems Electrical
Chapter 4 Utility Systems Electrical Utility Systems Electrical The electrical supply to your home begins outside, where you will see either an overhead feed and piping down the side of your home or (if
More informationCAL/OSHA ELECTRICAL LOW VOLTAGE
Preparation: Safety Mgr Authority: CEO Issuing Dept: Safety Page: Page 1 of 7 Purpose The purpose of this program is to prevent injuries due to electrical exposure to low voltage (less than or equal to
More informationDesign Standards NEMA
Design Standards Although several organizations are involved in establishing standards for the design, construction, and application of motor control centers, the primary standards are established by UL,
More informationA. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:
SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationPUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS
PUBLIC UTILITY DISTRICT NO. 1 OF LEWIS COUNTY METERING SPECIFICATIONS 1. General Metering Requirements a. Interpretation The District s metering requirements shall not be interpreted to conflict with the
More information7. SERVICES OVER 600 VOLTS
7. SERVICES OVER 600 VOLTS 7.1 GENERAL The Company shall always be consulted to obtain required design criteria where service is contemplated.preliminary plans of the Customer shall be submitted for review
More informationINSTALL CIRCUIT PROTECTIVE DEVICES
SUBCOURSE EN5146 EDITION B US ARMY ENGINEER CENTER AND SCHOOL INSTALL CIRCUIT PROTECTIVE DEVICES INSTALL CIRCUIT PROTECTIVE DEVICES Subcourse Number EN5146 EDITION B United States Army Engineer School
More information