TRANSMISSION CORPORATION OF TELANGANA LIMITED (Website: CIN No: U40102TG2014SGC094248)

Size: px
Start display at page:

Download "TRANSMISSION CORPORATION OF TELANGANA LIMITED (Website: CIN No: U40102TG2014SGC094248)"

Transcription

1 Regd. Post Ack.Due -1- TRANSMISSION CORPORATION OF TELANGANA LIMITED (Website: CIN No: U40102TG2014SGC094248) From The Chief Engineer /P&MM, Room No.-207, B-Block, TSTRANSCO, Vidyut Soudha, Hyderabad To M/s. Dubas Engineering Pvt. Ltd., #43(p), Electronics City II-Phase, Hosur Main Road, Banglaore Tel: P.O.No. 249 PMM/2018/CE/P&MM/SE/P&MM/DE31/F. TSPMM31-43/2017(Battery & Battery Chargers) /D.No.326/18, dt Sirs, Sub:- TSTRANSCO - P&MM Telecom - Specn.no.TSPMM31-43/2017 Supply, Erection & Commissioning of 48V Battery and Battery Chargers Detailed Purchase Order - Issued - Reg. Ref:- 1. Tender Specification No.TSPMM31-43/ Your offer on e- platform against Specification No. TSPMM31-43/ LOI.No.CE/P&MM /SE/P&MM/DE-31/F.TSPMM31-43/2017/D.No.133/18, Dt Your LOI acknowledgement vide Lr., Dt: ***** I, acting for and on behalf of and by the order and direction of TRANSMISSION CORPORATION OF TELANGANA LTD., (herein after called the "TSTRANSCO" or "the purchaser") accept your offer, vide ref. 2 nd cited, for Supply, Erection & Commissioning of 48V Battery and Battery Chargers for the quantities, as per the provision for quantity variation vide clause 34 (Section III, GTC) of tender specification, at an evaluated total package cost of Rs. 2,46,77, (Rupees Two Crores Forty Six Lakhs Seventy Seven Thousand and Seven Hundred and Sixty One only) as indicated below and the details are in Annexure-1 (Schedule of Prices). This Purchase Order is issued in confirmation of LOI issued vide ref.(3) cited, accepted by you vide ref.(4) cited. SCOPE OF CONTRACT: This contract relates to the Supply, Erection & Commissioning of 48V Battery and Battery Chargers detailed under clause (2) below and covers design, manufacture, testing before dispatch, delivery F.O.R. destination. Contd P/2

2 2) SCHEDULE OF MATERIALS AND PRICES: Supply, Erection & Commissioning of 48V Battery and Battery Chargers (inclusive of Freight, Insurance, Packing & Forwarding and GST) detailed in annexure. Sl. No Description Supply, Erection & Commissioning of 48V Battery and Battery Chargers including all Taxes. (Details in Annexure-I) Total Package value: Total Amount (in Rs.) 2,46,77, ,46,77, (Rupees Two Crores Forty Six Lakhs Seventy Seven Thousand and Seven Hundred and Sixty One only) 2.1 The Prices accepted above are FIRM during the process of the contract and until the warranty period is completed. 2.2 The prices accepted are inclusive of Freight, Insurance, Packing & Forwarding and GST. 2.3 The above prices are inclusive of unloading charges at destination stores. 2.4 M/s. Dubas Engineering Pvt. Ltd is responsible for all the Taxes applicable on this contract. 2.5 Income Tax, other taxes if any, will only be towards the supplier s account and would be recovered from the supplier bills for arranging payment as directed by the concerned department. 2.6 STATUTORY VARIATION: It is responsibility of bidder to consider the correct rates of the duties and taxes leviable on the equipment/material/work at the time of bidding. After considering the correct rates of duties and taxes only the bidder shall quote the prices. Any variation up or down in statutory levy or new levies introduced after tender calling date under this specification will be to the account of TSTransco, provided in cases where delivery schedule is not adhered to by the contractor/manufacturer and there are upward variation/revision after the agreed delivered date, the contractor/manufacturer will bear the impact of such levies and if there is downward variation/revision, the TSTransco will be given credit to the effect. In case of bought out items statutory variation shall not be applicable on that taxes and duties. For this purpose, bought out items means the material/equipment not manufactured by the bidder i.e. statutory variation will be applicable on taxes and duties involving direct transaction between bidder and TSTransco only and not for the taxes and duties between the bidder and his sub vendors. 2.7 The purchaser reserves the right to vary the order quantity by ±50 % during execution of the contract. Contd P/3

3 -3-3) DELIVERY: (Details are in Annexure-2) a. Consignment -1: The Supplies shall be completed within 2 months from the date of issue of LOI. Erection and Commissioning of the equipment shall be completed within 1 month from the date of intimation from TSTransco, for the Substations which are ready. b. Consignment -2: The Supplies shall be completed within 2 months thereafter (i.e., 4 Months from the date of issue of LOI). Erection and Commissioning of the equipment shall be completed within 1 month from the date of intimation from TSTransco, for the Substations which are ready. 4) FREIGHT & TRANSIT INSURANCE: Insurance shall be arranged by the supplier to cover transit risks and 45 days storage cover at site. The insurance will be in an amount equal to 100% FADS value of equipment on all-risks basis. The policy shall have a provision for extension to cover further storage if necessary at destination stores/site at TSTransco cost. 5) DESPATCH INSTRUCTIONS: The Dispatch instructions for the equipment will be issued separately after inspection. The details of consignee, paying officer and other officers will be furnished along with dispatch instructions, while approving the Inspection/Test Certificates. 6) PERFORMANCE SECURITY: 6.1 The supplier shall furnish to the purchaser the performance security in the name of The Chief Engineer/P&MM, TSTransco, VidyutSoudha, Hyderabad-82, for an amount equal to 10% of the total contract value i.e. for an amount of Rs. 24,67,776/- for proper fulfillment of the contract, shall include the warranty period and completion of performance obligations including warranty obligations. The performance security will cover 60 days beyond the date of completion of performance obligations including warranty obligations. 6.2 The performance security shall be executed in accordance with the clause (6), furnished on a stamp paper of value Rs.100/-. The B.G shall be extended if required suitably, in accordance with the provisions of Clause (38) of specification. 6.3 In the event of any correction of defects or replacement of defective material during the warranty period, the warranty for the corrected / replaced material shall have to be extended to a further period of 12 months and the Performance Bank Guarantee for proportionate value shall have to be extended 60 days over and above the extended warranty period. The proceeds of the performance security shall be payable to the Purchaser as compensation for any loss resulting from the Supplier s failure to fulfill its obligations under the Contract. Contd P/4

4 The performance security will be a). b). A bank guarantee issued by a scheduled bank not acceptable to the Purchaser, in the form provided in the bidding documents. The Bank guarantees may be obtained from the state Bank of India or Nationalized Banks. A banker s Cheque or crossed DD or Pay Order payable at the Head quarter of the Purchaser in favor of the Purchaser drawn on any scheduled bank/ state Bank of India or Nationalized Banks. 7) TERMS OF PAYMENT:- i) a) 80% payment towards the equipment cost will be arranged within 45 days for the material/equipment supplied in complete shape subject to their delivery as per the schedule of work and on its receipt in good condition at the destination / stores (i.e., from check measurement date in Form-13), on prorata basis against the submission of the following documents. i) Form 13 ii) Contractor's detailed invoice iii) Detailed Challan Acknowledged by Consignee iv) Manufacturer s/supplier s Warranty Certificates v) Approved Test Certificates vi) Copy of Insurance Policy Certificate vii) Copy of Acceptance Letter of Performance Security issued by Purchaser One additional copy each of the above and delivery challan shall be sent to the consignees. Copies of the above documents shall be sent to the Chief Engineer/ P&MM/TSTransco, VidyutSoudha, Hyderabad-82 immediately after delivering the materials at the destination stores. b) 10% payment towards equipment cost will be made after erection of equipment/ material on prorata basis against the submission of invoice. ii) c) Balance 10% payment towards equipment cost will be made along with the total erection & commissioning charges after commissioning of equipment / material duly certified by concerned Divisional Engineer/Telecom on prorata basis against the submission of invoice. The Supplier Bank details are as detailed below for RTGS payment (Real Time Gross Settlement). 1 Vendor Name Dubas Engineering Pvt. Ltd 2 Complete Address M/s. Dubas Engineering Pvt. Ltd., #43(P), Electronic City II-Phase, Hosur Main Road, Bangalore ,Tel: Name of the Bank AXIS Bank Ltd. 4 Branch Address Corporate Banking Branch, Express Building, 2 nd Floor, No.1 Queens Road, Bangalore Swift Code AXISINBBA06 6 Account No IFSC No. UTIB Income Tax PAN No. AAACD7283M Contd P/5

5 -5- The Bank details as above are final and shall not be revoked under any circumstances. The Bank Charges if any will be made to the account of M/s. Dubas Engineering Pvt. Ltd, and will be recovered from the bill amount per each disbursement on LOA raised by unit officers. No interest will be payable in case the payment is delayed for whatever reason. The Banker charges involved if any in establishing and operating the Cheque / Bills shall be to your account. iii) iv) If the supplier has received any over-payments by mistake or if any amounts are due to the TSTransco due to any other reason, when it is not possible to recover such amounts under this contract, the TSTransco reserves the right to collect the same from any other amounts and / or Bank guarantees given by you due to or with the TSTransco. The supplier should invariably submit Inspection/test certificates and other documents that the purchaser specifies, before dispatch is made so that they can be checked and approved well before it is dispatched and due for payment. v) When the supplier does not at any time, fulfill his obligations in replacing / rectifying etc. of the damaged / defective materials in part or whole, promptly to the satisfaction of the TSTransco Officers, the TSTransco reserves the right not to accept the bills against subsequent dispatches made by the supplier and only the supplier will be responsible for any demurrages, wharf ages or damage occurring to the consignments so dispatched. 8) CURRENCY OF PAYMENT: All payments will be made in non-convertible Indian Rupees. 9) WARRANTY: The equipment shall be guaranteed for satisfactory performance for a period of 36 months from the date of check measurement in form-13 i.e the date of receipt of goods in the departmental stores/site in good condition. During this period, if the equipment is found defective it shall be replaced or repaired by you free of all costs to the TSTRANSCO within 30 days, which shall in no circumstances be more than the delivery period indicated in this order. In the event of any correction of defects or replacement of defective material during the warranty period, the warranty for the corrected / replaced material shall be extended to a further period of 12 months and the Performance Bank Guarantee for proportionate value shall be extended 60 days over and above the extended warranty period. The proceeds of the performance security shall be payable to the Purchaser as compensation for any loss resulting from the Supplier s failure to fulfill its obligations under the Contract. Contd P/6

6 -6-10) RESPONSIBILITY OF THE SUPPLIER FOR LOSS OR DAMAGE: The supplier is responsible for the safe delivery of the goods in good condition at the destination stores. He should acquaint himself of the conditions prevailing for handling and transport of the goods to the destination and shall include and provide for security and protective packing of the goods so as to avoid damage in transit. 11) PACKING: The supplier shall provide such packing of the Materials / equipment as is required to prevent their damage or deterioration during transit to their final destination, as indicated technical specification. The packing shall be sufficient to withstand, without limitation, rough handling during transit and exposure to extreme temperatures, salt and precipitation during transit, and open storage. Packing case size and weights shall take into consideration, where appropriate, the remoteness of the Materials / equipment final destination and the absence of heavy handling facilities at all points in transit. 12) INSPECTION: The accredited representative of the TSTransco have access to you or your sub-contractor s works at any time during the working hours for the purpose of inspecting the materials during manufacture of the plant and equipment and testing, and may select samples from the materials going into the plant and equipment. You shall on such occasions provide proper and adequate facilities for testing the selected samples at any time. The final acceptance tests and routine tests shall be conducted in the presence of TSTransco's representative who will be deputed for the purpose. The program of inspection is to be intimated to the TSTransco with 15 days prior notice for acceptance tests. The goods shall not be dispatched until such inspection is conducted or waived in writing and followed by dispatch clearance communicated by the purchaser in writing. 13) TESTS AND CERTIFICATES: Three copies of the test certificates containing the results of all the tests including acceptance and routine tests carried out shall be forwarded to Chief Engineer/P&MM and got approved before the presentation of the bills for payment. The manufacturer's test certificates shall be submitted immediately after the acceptance tests are conducted and got approved before the equipment is dispatched. 14) GUANTED TECHNIAL PARTICULARS The Guaranteed Technical Particulars are indicated in Annexure-3 (A, B, C, D, E and F). 15) DRAWINGS: Drawings of 48V/35(1+1), 48V/50A(1+1) & 48V/100A(1+1) Battery Chargers and 48V/200AH, 48V/250AH, 48V/400AH Battery sets were approved vide Lr.No.CE/ P&MM /SE/P&MM/DE-31/F.TSPMM31-43/2017(Batt.) /D.No.310/18, Dt Contd P/7

7 -7-16) GENERAL CONDITIONS OF CONTRACT: Except in so far as it is provided otherwise in this contract, you shall abide by the terms and conditions indicated in the Tender specification No. TSPMM31-43/2017 which includes the TSTransco's General Terms and Conditions of contract' enclosed to the ref (1). Except as specifically accepted in this order, the terms and conditions mentioned in your quotation under reference are not accepted. 17) RISK: The risk in the property is entirely yours till the goods are received in good condition at destination stores as certified by the consignee. 18) PENALTY FOR DELAY IN SUPPLIES: The time for and the dates for delivery mentioned in the contract will be deemed to be the essence of the contract. Subject to force majeure clause No.18, if the supplier fails to deliver any or all of the Materials / equipment or fails to perform the services within the period (s) specified in the Contract, the purchaser will, without prejudice to its other remedies under the Contract, deduct from the Contract Price, as liquidated damages, a sum equivalent to 0.5% per week on the undelivered portion subject to a maximum of 5% of the total value of the contract. Once the maximum is reached the Purchaser may consider termination of the contract. The check measurement date in form-13 i.e., date of receipt of materials at destination stores/site in good condition will be taken as the date of delivery. Materials / Equipment which are not of acceptable quality or are not conforming to the specification would be deemed to be not delivered. For penalty, the number of days would be rounded off to the nearest week and penalty calculated accordingly. The penalty specified above will be levied and would be adjusted against subsequent pending bills. 19) FORCE MAJEURE: The Supplier will not be liable for forfeiture of its performance security, penalty for late delivery, or termination for default if and to the extent that its delay in performance or other failure to perform its obligations under the Contract is the result of an event of Force Majeure. For purposes of this clause, Force Majeure means an event beyond the control of the supplier and not involving the Supplier s fault or negligence and not foreseeable. Such events may include, but are not restricted to, wars or revolutions, fires, floods, epidemics, quarantine restrictions, and freight embargoes. If a Force Majeure situation arises, the supplier will promptly notify the Purchaser in writing of such condition and the cause thereof. Unless or otherwise directed by the Purchaser in writing, the Supplier will continue to perform its obligations under the Contract as far as is reasonable in practice, and will seek all reasonable alternative means for performance not prevented by the Force Majeure event. No price variance will be allowed during the period of force majeure. Contd P/8

8 -8-, 20) CORRESPONDANCE: Your acknowledgement to this order and any correspondence, general or technical in nature shall be addressed to the Chief Engineer/P&MM, TSTransco, Vidyut Soudha, Hyderabad All correspondence regarding dispatch and payment shall be addressed to the consignee under intimation to the Chief Engineer/P&MM, Vidyut Soudha, Hyderabad ) COMPLETENESS OF CONTRACT: All minor accessories that are normally necessary for satisfactory and efficient operation of the equipment shall be supplied by you free of cost to the TSTransco, whether these are specifically mentioned or not in the specification, your tender schedules or in this Purchase Order and the equipment shall be complete in itself. 22) OPERATION AND MAINTENANCE MANUALS: One set of Manuals consisting of operating instructions and programming schedules and approved drawings for each of the equipment shall be supplied in the package along with respective equipment s at the time of dispatch. They shall contain clear instructions on erection, commissioning and maintenance for the guidance of operating staff. Any items requiring the special attention of the Operation Engineer shall be highlighted. 23) CONTRACT AMENDMENTS: No variation in or modification of the terms of the contract will be made except by written amendment by the Purchaser and accepted by the supplier 24) TERMINATION FOR DEFAULT: 24.1 The purchaser, without prejudice to any other remedy for breach of contract, by written notice of default sent to the Supplier, may terminate this Contract in whole or in part: i. If the supplier fails to deliver any or all of the Materials / equipment within the period(s) specified in the Contract, or within any extension thereof granted by the Purchaser. ii. iii. If the supplier fails to perform any other obligations under the contract. If the supplier, in the judgment of the purchaser has engaged incorrupt or Fraudulent practices in competing for or in executing the contract In the event the purchaser terminates the contract in whole or in part, the purchaser may procure, upon such terms and in such manner, as it deems appropriate, materials/ equipment or services similar to those undelivered, and the supplier will be liable to the purchaser for any excess costs for such similar materials/equipment or services. However, the supplier will continue performance of the contract to the extent not terminated. Contd P/9

9 -9-25) TERMINATION FOR INSOLVENCY: The Purchaser may at any time terminate the contract by giving written notice to the Supplier if the Supplier becomes bankrupt or otherwise insolvent. In this event, termination will be without compensation to the supplier, provided that such termination will not prejudice or not affect any right of action or remedy, which was accrued or will accrue thereafter to the Purchaser. 26) TERMINATION FOR CONVENIENCE: (a) The Purchaser, by written notice sent to the Supplier, may terminate the Contract, in whole or in part, at any time for its convenience. The notice of termination will specify the termination is for the Purchaser s convenience, the extent to which performance of the supplier under the Contract is terminated and date upon which termination becomes effective. (b) However the materials/equipment those are complete and ready for shipment within Thirty (30) days after the supplier s receipt of notice of termination will be accepted by the purchaser at the contract terms and prices. 27) JURISDICTION: All and any dispute or differences arising out of or touching this order will be decided by the courts or tribunals situated in Hyderabad or Secunderabad only. No suit or other legal proceedings will be instituted elsewhere. 28) ACKNOWLEDGEMENT: Please acknowledge this order soon on its receipt by returning the extra copy of the order enclosed, duly signing it with date in token of acceptance. Yours faithfully, Sd/- Encl.: 1. Annexures 1(Schedule of Prices) Chief Engineer/P&MM 2. Annexures 2 (Delivery Schedule) (Acting for and on behalf of TSTRANSCO) 3. Annexures 3 (GTPs) "WE ACCEPT THE TERMS AND CONDITIONS STIPULATED IN THIS P.O." Signature of the Contractor with seal Copy to: The Executive Director/Finance/ TSTransco/Vidyut Soudha/Hyderabad. The Pay Officer/TS TRANSCO/Vidyut Soudha/ Hyderabad The SAO/ P&A/ TSTransco/Vidyut Soudha/Hyderabad. The FA&CCA/ACCOUNTS/TSTransco/Vidyut Soudha/Hyderabad. The Chief Engineer/Telecom/Vidyuth Soudha/Hyderabad. The Superintending Engineer/Telecom/TSTransco /132/33KVSS Opp. to Court Jagityala road, Karimnagar Contd P/10

10 -10- The Superintending Engineer/Telecom/Metro/ TSTransco /132KVSS Chilakalaguda/ Hyderabad The Superintending Engineer/Telecom/ TSTransco / 220KV SS/ Mulugu Road / Warangal The Superintending Engineer/Telecom/Rural/ TSTransco / GTS Colony/ Erragadda/Hyderabad The SE/OMC/Metro-Central /Hyderabad /TSTransco/NIMS GIS/Erramanjil/Hyderabad. The SAO/OMC /Metro Central/ TSTransco/NIMS/ Hyd (Through ) The Superintending Engineer/OMC/Sangareddy (Through ) The Superintending Engineer/OMC/Mahaboobnagar (Through ) The Superintending Engineer/OMC/Nalgonda (Through ) The Superintending Engineer/400 KV/Construction/Metro/Hyderabad (Through ) The Superintending Engineer/OMC/Metro-West/Hyderabad (Through ) The Superintending Engineer/OMC/Metro-East/Hyderabad (Through ) The Superintending Engineer/OMC/Karimnagar (Through ) The Superintending Engineer/OMC/Nizamabad (Through ) The Superintending Engineer/OMC/Adilabad (Through ) The Superintending Engineer/OMC/Warangal (Through ) The Superintending Engineer/OMC/Khammam (Through ) The Divisional Engineer/Telecom/220KVSS/Mulugu Road/Warangal --- (Through ) The Divisional Engineer/ Telecom/132KVSS/Karim Nagar ---(Through ) The Divisional Engineer/ Telecom/132KVSS/Mettuguda/Mahaboobnagar---(Through ) The Divisional Engineer/ Telecom/ 132KVSS /Nizamabad ---(Through ) The Divisional Engineer/ Telecom/ 132KVSS /Adilabad---(Through ) The Divisional Engineer/ Telecom/ 132KVSS Nalgonda ---(Through ) The Divisional Engineer/ Telecom/132KVSS /Ellandu Road/Khammam ---(Through ) The Divisional Engineer/ Telecom/ Sangareddy/Mint Compound/First Floor Stone Building / Hyderabad (Through ) The Divl. Engineer/ Telecom/400KVSS/Mamidipalli/Pahad-e-Sharif/Hyd---(Through ) The Divisional Engineer/ Telecom/ Metro/Narayanaguda GIS/Hyderabad ---(Through ) The Divisional Engineer/Transmission Stores/ Metro-Central/Erragadda/GTS Colony/ Hyd. The Asst. Executive Engineer/Transmission Stores/220KVSS Shapurnagar/Hyd. Contd P/11

11 -11- Tender Specification No.: TSPMM31-43/2017; P.O.No.249, Dt.: Annexure-1(Schedule of prices) (All figures are in Indian Rupees) Sl. Description of No. the equipment UOM Total Tender ed Qty Units Exwork price Unit Freight charges Unit Insurance charges Packing and Forwarding Unit Erection & Unit landed Commis Price sioning charges % on Unit Ex- works +F+I+ P&F +E&C % on Unit Ex- works +F+I+ P&F+E&C Unit landed Price with taxes Total landed price inclusive of all taxes 48V Battery Chargers Supply, Erection & Commis sioning of 48V/35A (1+1) Float cum boost Charger Supply, Erection & Commis sioning of 48V/50A (1+1) Float cum boost Charger Supply, Erection & Commis sioning of 48V/100A (1+1) Float cum boost Charger 48 V Batteries Supply, Erection & Commis sioning of 48V/200 AH SMF VRLA Battery Set Supply, Erection & Commissioning of 48V/ 250 AH SMF VRLA Battery Set Supply, Erection & Commissioning of 48V/ 400 AH (1+1) SMF VRLA Battery Set Nos Nos Nos Nos Nos Nos Battery Cable Supply of 25 7 Sq.mm. Battery cable mtrs Total (Rs.) Or say in Rs. 2,46,77, (Rupees Two Crores Forty Six Lakhs Seventy Seven Thousand and Seven Hundred and Sixty One only) Sd/- Chief Engineer/P&MM Contd P/12

12 -12- Tender Specification No.: TSPMM31-43/2017;P.O. No.249, Dt.: Annexure-2 Delivery Schedule Sl. No Description of the equipment UOM Total Qty. Consignment- 1 Consignment- 2 Delivery Schedule Destination for delivery of material 1 Supply, Erection & Commissioning of 48V/35A(1+1) Float cum boost Charger 2 Supply, Erection & Commissioning of 48V/50A(1+1) Float cum boost Charger 3 Supply, Erection & Commissioning of 48V/100A(1+1) Float cum boost Charger 4 Supply, Erection & Commissioning of 48V/200 AH SMF VRLA Battery Set 5 Supply, Erection & Commissioning of 48V/ 250 AH SMF VRLA Battery Set 6 Supply, Erection & Commissioning of 48V/ 400 AH (1+1) SMF VRLA Battery Set 7 Supply of 25 Sq.mm. Battery cable Nos. Nos. Nos. Nos Consignment-1: The Supplies shall be completed within two months from the date of issue of LOI. Erection and commissioning of equipment shall be completed within one month for the substations which are ready from the date of intimation from TSTRANSCO Nos Nos mtrs Consignment-2: The Supplies shall be completed within two months thereafter (4 months from the date of LOI). Erection and commissioning of equipment shall be completed within one month for the substations which are ready from the date of intimation from TSTRANSCO Anywhere in Telangana State Sd/- Chief Engineer/P&MM Contd P/13

13 -13- Annexure-3 A. GUARANTEE TECHNICAL PARTICULAR FOR 48V, 35A (1+1) Float Cum Boost Charger 1 Manufacturer s Type & Designation DUBAS Make, DFCBC 48VDC,35A 2 Input AC supply a Voltage 1φ-2Wire, V AC b Frequency 50Hz, ±5% c Power Factor 0.8 at rated load minimum input 3 Type of Rectifier (IEC-60146) 1φ, Full wave controlled Bridge 4 Type of semiconductor material Silicon mono Crystalline 5 Automatic voltage regulator type Static control, Constant voltage current limit 6 Float cum boost charger rating a Auto Float voltage (Nominal) 53V (2.2Vpc) b Charger output continuous current 35A c Manual Float voltage Adjust (Through Pot) 50 56V, +/-5V (Recommended 2.27Vpc max. for VRLA) d Manual Boost voltage Adjust (Through Pot) 56 65V, +/-5V (Not recommended for VRLA) (Should be Off load boost charging) e Battery charging Current Adjust (Through Pot) 10 35A (Recommended 30A for 200Ah VRLA) f Load voltage (When chargers are healthy on float) 48 52V (By dropper diode. Dropper diodes will be bypassed by a contactor in case of AC mains fail to connect total battery across the DC load) g Load current (Max) 15A continuous (DVR Rated for ) 7 Auto / Manual feature is provided Yes 8 Rectifier Transformer (IS-2026) a Type Dry Type, Double Wound, Class-H insulation, Class-F temperature rise 9 In Auto mode, during trickle charging, the charger ±1% of set feedback point output voltage variation for specified AC voltage & Frequency variation 10 Maximum ripple content at rated load, nominal 4mV psophometric without battery connect input 11 Efficiency at Rated load, nominal input 75% 12 Maximum permissible temperature rise over an ambient temperature of 45 C. 110 C (For magnetic) 65 C (For Rectifier stack) 13 Protections a) Output soft start Yes b) Output over load 110% for short time c) Input UV/OV alarm, Thermal magnetic trip Yes d) Output short circuit & Over voltage Yes e) Total load current & Battery Current Limit Yes 14 Protection Class / Paint Shade IP-30 /631 of IS-5 15 Internal wiring 600/1100V grade, PVC insulated, stranded copper conductor 16 Measuring instruments Analog, Flush mount, 90º Scale, 72Sqmm, Class Indication & Alarms Refer Drawing 18 DCDB Detail (inbuilt) Feeder 06A, SP, DC MCB 18Nos 19 ADDB Detail (inbuilt) Feeder 06A, SPN, AC MCB 6Nos Sd/- Chief Engineer/P&MM Contd P/14

14 -14- Annexure-3 B. GUARANTEE TECHNICAL PARTICULAR FOR 48V, 50A (1+1) Float Cum Boost Charger 1 Manufacturer s Type & Designation DUBAS Make, DFCBC 48VDC,50A 2 Input AC supply a Voltage 1φ-2Wire, V AC b Frequency 50Hz, ±5% c Power Factor 0.8 at rated load minimum input 3 Type of Rectifier (IEC-60146) 1φ, Full wave controlled Bridge 4 Type of semiconductor material Silicon mono Crystalline 5 Automatic voltage regulator type Static control, Constant voltage current limit 6 Float cum boost charger rating a Auto Float voltage (Nominal) 53V (2.2Vpc) b Charger output continuous current 50A c Manual Float voltage Adjust (Through Pot) 50 56V, +/-5V (Recommended 2.27Vpc max. for VRLA) d Manual Boost voltage Adjust (Through Pot) 56 65V, +/-5V (Not recommended for VRLA) (Should be Off load boost charging) e Battery charging Current Adjust (Through Pot) 10 50A (Recommended 38A for 250Ah VRLA) f Load voltage (When chargers are healthy on float) 48 52V (By dropper diode. Dropper diodes will be bypassed by a contactor in case of AC mains fail to connect total battery across the DC load) g Load current (Max) 15A continuous 7 Auto / Manual feature is provided Yes 8 Rectifier Transformer (IS-2026) a Type Dry Type, Double Wound, Class-H insulation, Class-F temperature rise 9 In Auto mode, during trickle charging, the charger ±1% of set feedback point output voltage variation for specified AC voltage & Frequency variation 10 Maximum ripple content at rated load, nominal 4mV psophometric without battery connect input 11 Efficiency at Rated load, nominal input 75% 12 Maximum permissible temperature rise over an ambient temperature of 45 C. 110 C (For magnetic) 65 C (For Rectifier stack) 13 Protections a) Output soft start Yes b) Output over load 110% for short time c) Input UV/OV alarm, Thermal magnetic trip Yes d) Output short circuit & Over voltage Yes e) Total load current & Battery Current Limit Yes 14 Protection Class / Paint Shade IP-30 /631 of IS-5 15 Internal wiring 600/1100V grade, PVC insulated, stranded copper conductor 16 Measuring instruments Analog, Flush mount, 90º Scale, 72Sqmm, Class Indication & Alarms Refer Drawing 18 DCDB Detail (inbuilt) Feeder 06A, SP, DC MCB 24Nos 19 ADDB Detail (inbuilt) Feeder 06A, SPN, AC MCB 6Nos Sd/- Chief Engineer/P&MM Contd P/15

15 -15- Annexure-3 C. GUARANTEE TECHNICAL PARTICULAR FOR 48V, 100A (1+1) Float Cum Boost Charger 1 Manufacturer s Type & Designation DUBAS Make, DFCBC 48VDC,100A 2 Input AC supply a Voltage 1φ-2Wire, V AC b Frequency 50Hz, ±5% c Power Factor 0.8 at rated load minimum input 3 Type of Rectifier (IEC-60146) 1φ, Full wave controlled Bridge 4 Type of semiconductor material Silicon mono Crystalline 5 Automatic voltage regulator type Static control, Constant voltage current limit 6 Float cum boost charger rating a Auto Float voltage (Nominal) 53V (2.2Vpc) b Charger output continuous current 100A c Manual Float voltage Adjust (Through Pot) 50 56V, +/-5V (Recommended 2.27Vpc max. for VRLA) d Manual Boost voltage Adjust (Through Pot) 56 65V, +/-5V (Not recommended for VRLA) (Should be Off load boost charging) e Battery charging Current Adjust (Through Pot) A (Recommended 60A for 400Ah VRLA) f Load voltage (When chargers are healthy on float) 48 52V (By dropper diode. Dropper diodes will be bypassed by a contactor in case of AC mains fail to connect total battery across the DC load) g Load current (Max) 40A continuous 7 Auto / Manual feature is provided Yes 8 Rectifier Transformer (IS-2026) a Type Dry Type, Double Wound, Class-H insulation, Class-F temperature rise 9 In Auto mode, during trickle charging, the charger ±1% of set feedback point output voltage variation for specified AC voltage & Frequency variation 10 Maximum ripple content at rated load, nominal 4mV psophometric without battery connect input 11 Efficiency at Rated load, nominal input 75% 12 Maximum permissible temperature rise over an ambient temperature of 45 C. 110 C (For magnetic) 65 C (For Rectifier stack) 13 Protections a) Output soft start Yes b) Output over load 110% for short time c) Input UV/OV alarm, Thermal magnetic trip Yes d) Output short circuit & Over voltage Yes e) Total load current & Battery Current Limit Yes 14 Protection Class / Paint Shade IP-30 /631 of IS-5 15 Internal wiring 600/1100V grade, PVC insulated, stranded copper conductor 16 Measuring instruments Analog, Flush mount, 90º Scale, 72Sqmm, Class Indication & Alarms Refer Drawing 18 DCDB Detail (inbuilt) Feeder 06A, SP, DC MCB 24Nos 19 ADDB Detail (inbuilt) Feeder 06A, SPN, AC MCB 6Nos Sd/- Chief Engineer/P&MM Contd P/16

16 -16- Annexure-3 D. GUARANTEE TECHNICAL PARTICULAR FOR 48V UPST 200Ah VRLA Battery 1 Manufacturer s Type & Designation Exide Make 48V UPST 200Ah VRLA Battery 2 Capacity in AH at 27 C (i) Initial 200 (ii) Rated 200 (iii) End of Life Capacity at Various Discharge Rates at 27 C Period of 10Hr Discharge for 200 AH Capacity Discharge Current Amp a End Cell Voltage Volts Period of 1Hr Discharge for 100 AH Capacity Discharge Current Amp b End Cell Voltage- 1.7 Volts Maximum Momentary Current for 1 min 600 Amps 4 up to cut off voltage of 1.6 V 5 Expected Fault at bus due to battery 1200 Amps 6(i) Short Circuit Current at Battery terminals 1200 Amps (ii) Time for which the battery can withstand short circuit at terminals 5 Sec 7 Type/No. of Negative Plates per cell Flat pasted, 4(I) + 2(E) 8 Type/No. of Positive Plates per cell Flat pasted 5 9 Size of negative plates, mm 315(L) x 140(W) x 2.65 (+/- 1) (Thk) (Inter) 315(L) x 140(W) x 1.9 (+/- 1) (Thk) (End) 10 Size of positive plates, mm 315(L) x 140(W) x 4.5 (+/- 1) (Thk) 11 Type of Connection between cells Bolted rigid copper connectors 12 Type of Separators Absorptive glass mat 13 Thickness of Separators 4.2 (2 layers of 2.1 mm each) 14 Dimension of 2 volts cell ( LXWXH ), mm 167(+/-3)mm x 87(+/-3)mm x 394 (+/- 5) mm 15 Material of Container Polypropylene Co-polymer 16 Recommended Charging Rate (i) Float Charging Voltage between ambient temp. (-)5-14 C / VPC between ambient temp C / VPC between ambient temp C / VPC between ambient temp C / VPC (ii) Float Charging Current 30 Amps (Max) (iii) Boost Charging Voltage 2.35 Volts (iv) Boost Charging Current 40 Amps (v) Time taken to full charge from 100% discharge state by constant voltage charging & voltage at the end of this charge 72 Hrs (Min) 2.1 volts(ocv) 17 Guaranteed efficiencies at 10 hrs rate 18 (a) Ampere-hour efficiency 90% (b) Watt-hour efficiency 80% Internal Resistance of each cell at Fully Charged Condition 0.99 milli ohms min Contd P/17

17 19 Overall Dimensions of each complete module with Top Cover( LxWxH) in mm -17- Length 588 +/- 5, Width 415 +/- 5(w/o base member), Width 452 +/-5 (with base member), Height 210 +/- 5; ( 6 cells module); 20 Weight of unpacked and complete module with electrolyte ; Kgs /- 5% Kgs (Single 6 cell module) 21 Material of Modules Powder coated MS 22 Yes, self re-sealing rubber safety valve with Whether explosion vents are offered flame arrestor 23 The period for which the battery should be stored after supply in charged conditions If stored in Indian ambient temp of 30 deg C cells will need freshening charge once in every three months, however if stored at higher or lower temperature freshening charge to be provided as recommended. 24 Amount of Hydrogen evolved during normal normal float charging Less than 200ppm normal float condition 25 Recommended interval at which battery should be discharged at 10 hr discharge rate Once annually 26 No. of charge-discharge cycle battery can give during its entire life at 20% DOD 4000 cycles at 50% DOD 1800 cycles at 80% DOD 1400 cycles 27 Expected Life of Battery in years 20 Yrs at 27 deg C in ideal float condition. 28 Applicable standard IEC & 22, JIS : C , : 1998, ANSI T1 330, GR/BAT-01/03-MARCH 2004, IS : 2005 Sd/- Chief Engineer/P&MM Contd P/18

18 -18- Annexure-3 E. GENERAL TECHNICAL PARTICULAR FOR 48V UPST 250Ah VRLA Battery 1 Manufacturer s Type & Designation Exide Make 48V UPST 250Ah VRLA Battery 2 Capacity in AH at 27 C (i) Initial 250 (ii) Rated 250 (iii) End of Life Capacity at Various Discharge Rates at 27 C a Period of 10Hr Discharge for 250 AH Capacity Discharge Current Amp End Cell Voltage Volts b Period of 1Hr Discharge for 125 AH Capacity Discharge Current Amp End Cell Voltage- 1.7 Volts 4 Maximum Momentary Current for 1 min 750 Amps up to cut off voltage of 1.6 V 5 Expected Fault at bus due to battery 1500 Amps 6(i) Short Circuit Current at Battery terminals 1500 Amps Time for which the battery can 5 Sec (ii) withstand short circuit at terminals 7 Type/No. of Negative Plates per cell Flat pasted; 7 8 Type/No. of Positive Plates per cell Flat pasted; 6 9 Size of negative plates, mm 315(L) x 140(W) x 2.65 (+/- 1) (Thk) 10 Size of positive plates, mm 315(L) x 140(W) x 4.5 (+/- 1) (Thk) 11 Type of Connection between cells Bolted rigid copper connectors 12 Type of Separators Absorptive glass mat 13 Thickness of Separators 4.2 (2 layers of 2.1 mm each) 14 Dimension of 2 volts cell ( LXWXH ), mm 167(+/-3)mm x 126(+/-3)mm x 394 (+/- 5) mm 15 Material of Container Polypropylene Co-polymer 16 Recommended Charging Rate (i) Float Charging Voltage between ambient temp. (-)5-14 C / VPC between ambient temp C / VPC between ambient temp C / VPC between ambient temp C / VPC (ii) Float Charging Current 37.5 Amps (Max) (iii) Boost Charging Voltage 2.35 Volts (iv) Boost Charging Current 50 Amps (v) Time taken to full charge from 100% discharge state by constant voltage charging & voltage at the end of this charge 17 Guaranteed efficiencies at 10 hrs rate (a) Ampere-hour efficiency 90% 72 Hrs (Min) 2.1 volts(ocv) (b) Watt-hour efficiency 80% 18 Internal Resistance of each cell at Fully 0.86 milli ohms min Charged Condition 19 Overall Dimensions of each complete modular ( LxWxH) in mm Length 588 +/- 5, Width 460 +/- 5, Height 288 +/- 5; ( 6 cells module); 20 Weight of unpacked and complete module 100 +/- 5% Kgs (Single 6 cell module) with electrolyte ; Kgs 21 Material of Modules Powder coated MS Contd P/19

19 Whether explosion vents are offered Yes, self re-sealing rubber safety valve with flame arrestor 23 The period for which the battery should be stored after supply in charged conditions If stored in Indian ambient temp of 30 deg C cells will need freshening charge once in every three months, however if stored at higher or lower temperature freshening charge to be provided as recommended. 24 Amount of Hydrogen evolved during normal Less than 200ppm normal float condition float charging 25 Recommended interval at which battery should be discharged at 10 hr discharge rate Once annually 26 No. of charge-discharge cycle battery can give during its entire life at 20% DOD 4000 cycles at 50% DOD 1800 cycles at 80% DOD 1400 cycles 27 Expected Life of Battery in years 20 Yrs at 27 deg C in ideal float condition. 28 Applicable standard IEC & 22, JIS : C , : 1998, ANSI T1 330, GR/BAT-01/03-MARCH 2004, IS : 2005 Sd/- Chief Engineer/P&MM Contd P/20

20 -20- Annexure-3 F. GENERAL TECHNICAL PARTICULAR FOR 48V UPST 400Ah VRLA Battery 1 Manufacturer s Type & Designation Exide Make 48V UPST 400Ah VRLA Battery 2 Capacity in AH at 27 C (i) Initial 400 (ii) Rated 400 (iii) End of Life Capacity at Various Discharge Rates at 27 C a Period of 10Hr Discharge for 400 AH Capacity Discharge Current Amp End Cell Voltage Volts b Period of 1Hr Discharge for 200 AH Capacity Discharge Current Amp End Cell Voltage- 1.7 Volts Maximum Momentary Current for 1 min up 1200 Amps 4 to cut off voltage of 1.6 V 5 Expected Fault at bus due to battery 2400 Amps 6(i) Short Circuit Current at Battery terminals 2400 Amps Time for which the battery can 5 Sec (ii) withstand short circuit at terminals 7 Type/No. of Negative Plates per cell Flat pasted; 11 8 Type/No. of Positive Plates per cell Flat pasted; 10 9 Size of negative plates, mm 315(L) x 140(W) x 2.65 (+/- 1) (Thk) 10 Size of positive plates, mm 315(L) x 140(W) x 4.5 (+/- 1) (Thk) 11 Type of Connection between cells Bolted rigid copper connectors 12 Type of Separators Absorptive glass mat 13 Thickness of Separators 4.5 (2 layers of 2.25 mm each) 14 Dimension of 2 volts cell ( LXWXH ),mm 167(+/-3)mm x 172(+/-3)mm x 378 (+/- 5) mm) 15 Material of Container Polypropylene Co-polymer 16 Recommended Charging Rate (i) Float Charging Voltage between ambient temp. (-)5-14 C / VPC between ambient temp C / VPC between ambient temp C / VPC between ambient temp C / VPC (ii) Float Charging Current 60 Amps (Max) (iii) Boost Charging Voltage 2.35 Volts (iv) Boost Charging Current 80 Amps (vii) Time taken to full charge from 100% discharge state by constant voltage charging & voltage at the end of this charge 17 Guaranteed efficiencies at 10 hrs rate (a) Ampere-hour efficiency 90% 72 Hrs (Min) 2.1 volts(ocv) (b) Watt-hour efficiency 80% 18 Internal Resistance of each cell at Fully 0.42 milli ohms min Charged Condition 19 Overall Dimensions of each complete modular ( LxWxH) in mm Length 619 +/- 5, Width 445 +/- 5, Height 388 +/- 5; ( 6 cells module); Contd P/21

21 Weight of unpacked and complete module /- 5% Kgs (Single 6 cell module) with electrolyte ; Kgs 21 Material of Modules Powder coated MS 22 Whether explosion vents are offered Yes, self re-sealing rubber safety valve with flame arrestor 23 The period for which the battery should be stored after supply in charged conditions If stored in Indian ambient temp of 30 deg C cells will need freshening charge once in every three months, however if stored at higher or lower temperature freshening charge to be provided as recommended. 24 Amount of Hydrogen evolved during normal Less than 200ppm normal float condition float charging 25 Recommended interval at which battery should be discharged at 10 hr discharge rate Once annually 26 No. of charge-discharge cycle battery can give during its entire life at 20% DOD 4000 cycles at 50% DOD 1800 cycles at 80% DOD 1400 cycles 27 Expected Life of Battery in years 20 Yrs at 27 deg C in ideal float condition. 28 Applicable standard IEC & 22, JIS : C , : 1998, ANSI T1 330, GR/BAT-01/03-MARCH 2004, IS : 2005 Sd/- Chief Engineer/P&MM

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm

TENDER. Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm TENDER Enq. No. IIITMK/ 0648/18 Date: 07/09/18 Due on:17/09/20183pm On behalf of INDIAN INSTITUTE OF INFORMATION TECHNOLOGY & MANAGEMENT KERALA (IIITMK), the Registrar invites offers for supply and laying

More information

Tender documents for supply, erection & commissioning of Plante Type Battery to 2x210 MW IB Thermal Power Station.

Tender documents for supply, erection & commissioning of Plante Type Battery to 2x210 MW IB Thermal Power Station. ORISSA POWER GENERATION CORPORATION LIMITED IB THERMAL POWER STATION AT/P.O: BANHARPALI, DIST: JHARSUGUDA, PIN: 768234 (ORISSA), INDIA GRAM: IB THERMAL, TEL: 06645-222209/222210, FAX: 06645-222209/54/30

More information

Section VI: List of Requirements (REVISED)

Section VI: List of Requirements (REVISED) As per Technical Specifications attached in Section VII Date: 18/06/2018 of Electrical Items With reference to the above tender, the following Corrigendum may kindly be noted against the Section VI, Section

More information

DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED. (A Govt of West Bengal Enterprise)

DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED. (A Govt of West Bengal Enterprise) DETAILED NOTICE INVITING TENDER WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED (A Govt of West Bengal Enterprise) CHIEF ENGINEER (PROCUREMENT), VIDYUT BHAVAN NOTICE INVITING TENDERS For CONSTRUCTION

More information

THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore (M.P.) REQUIREMENT

THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore (M.P.) REQUIREMENT THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore -452003 (M.P.) ANNEXURE -III REQUIREMENT OICL intends to procure reputed brand Exide or Amara Raja or

More information

SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT /

SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT / SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT / 2005-06 SR.NO ITEM PAGE 1. SCOPE 2 2. WEATHER CONDITIONS 2 3. RATED VOLTAGE & FREQUENCY 2 4. GENERAL REQUIREMENT

More information

Supply of Batteries

Supply of Batteries Supply of Batteries 207-8 SUPPLY OF BATTERIES OF VARIOUS RATINGS E-PROCUREMENT (REVERSE AUCTION) NIT No: 07/ 207-8 Name of the work Supply of Batteries to our Branches / Offices /ATM Completion Time EMD

More information

ANNEXURE XI. (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I.

ANNEXURE XI. (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I. ANNEXURE XI (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I. Sr. No Technical Particulars Confirmation to be given by bidder (Please strike out which ever not applicable)

More information

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/48

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/48 INVITATION FOR QUOTATION TEQIP-III/2018/uceo/Shopping/48 29-Dec-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the

More information

Supply, Installation and Commissioning of 1 No 50 Watt LED. based SPV SLS at Nadia District Library, Krishna Nagar, Nadia.

Supply, Installation and Commissioning of 1 No 50 Watt LED. based SPV SLS at Nadia District Library, Krishna Nagar, Nadia. Supply, Installation and Commissioning of 1 No 50 Watt LED based SPV SLS at Nadia District Library, Krishna Nagar, Nadia. TENDER DOCUMENT. (A Govt. of West Bengal Company) Bikalpa Shakti Bhavan, Plot J1/10,

More information

Section V DC Nickel Cadmium Alkaline BATTERY

Section V DC Nickel Cadmium Alkaline BATTERY Section - 7 TECHNICAL SPECIFICATION OF 110V DC Nickel Cadmium Alkaline BATTERY TECHNICAL SPECIFICATIONS & REQUIREMENTS OF 110V DC Nickel Cadmium Alkaline Battery 7. 1 GENERAL This section of the document

More information

Technical Specifications

Technical Specifications LT Distribution Box Technical Specifications 1. SCOPE 1.1 This specification covers design, manufacture, testing at manufacturer works before dispatch and supply of L.T. Distribution Cabinet suitable for

More information

SPECIFICATIONS FOR 50 V, 600 AH LEAD ACID BATTERY

SPECIFICATIONS FOR 50 V, 600 AH LEAD ACID BATTERY (I) INTRODUCTION: Power Line Carrier Communication (PLCC) System is being used by Gujarat Energy Transmission Corporation Ltd. for Speech, Data, Protection and Teleprinter signal transmission purpose throughout

More information

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS FOR 220 V BATTERY CHARGER

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS FOR 220 V BATTERY CHARGER GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR 220 V BATTERY CHARGER GETCO / E / TS- BCHR 3202 / R2 Oct 15 Seal & Sign

More information

Supply of 63 kva DIESEL GENERATOR SET WITH AMF

Supply of 63 kva DIESEL GENERATOR SET WITH AMF No. NIQ/INKEL/2015-16/162 24 TH Nov 2015 NOTICE INVITING QUOTATION Sealed Quotations are invited for and on behalf of INKEL Limited, having its registered office at INKEL Centre, Off Vallathol junction,

More information

INDIAN MARITIME UNIVERSITY KOLKATA CAMPUS

INDIAN MARITIME UNIVERSITY KOLKATA CAMPUS INDIAN MARITIME UNIVERSITY KOLKATA CAMPUS No. IMU-KC/Laboratory Equipment/16-17 Date: 17.02.2017 Sub: Quotation for procurement of Instruments for Electrical Machine Laboratory at IMU-Kolkata Campus Sealed

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED

BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED GUIDELINES FOR EMPANELMENT OF GRID TIED INVERTER MANUFACTURERS FOR IMPLEMENTATION OF SRTPV PROGRAM IN BESCOM. I. NEW EMPANELMENT 1. The grid tied inverter manufacturer shall register their application

More information

INDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING

INDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING To, Ref No: IIT/ EE/SMART CITY/INVERTER AND BATTERY SET/2015/02 INVITATION FOR QUOTATIONS FOR SUPPLY OF THE FOLLOWING ITEMS REQUIRED FOR SMART CITY PILOT PROJECT AT IIT KANPUR S.No. Brief Description of

More information

/ Telefax : No: 1(2)2015-E/ Battery& Charger TVH/ Dated:

/ Telefax : No: 1(2)2015-E/ Battery& Charger TVH/ Dated: प रस र भ रत / PRASAR BHARATI (भ रत य ल क स व प रस रक / INDIA S PUBLIC SERVICE BROADCASTER) द रदर शन क न द र / DOORDARSHAN KENDRA ह दर ब द / HYDERABAD 500 013.. Email : sgeddh@yahoo.com / sgeddh@gmail.com

More information

TENDER FOR DG SET. Tender for DG SET. POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI Website: TENDER DOCUMENTS FOR

TENDER FOR DG SET. Tender for DG SET. POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI Website:  TENDER DOCUMENTS FOR Cost of the Tender Form - Rs.500/- (Rupees Five Hundred only) Tender Form No.MCI/TENDER DGSET/2018 Tender for DG SET MEDICAL COUNCIL OF INDIA POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI 110 077 Website:

More information

Tender No:- MTL/PUR/213/Elect/ (K)/9. 2 NEW Moulded case Circuit Breaker with O/L & S/C No 02

Tender No:- MTL/PUR/213/Elect/ (K)/9. 2 NEW Moulded case Circuit Breaker with O/L & S/C No 02 Tender No:- MTL/PUR/213/Elect/2015-16 (K)/9 Date:-26/10/2016 Type Of Bid Bidding type Bid closing On Bid Opening On EMD : LIMITED TENDER : Single Bid : 18/11/2016 at 14.00 hrs.(ist) : : As per Annexure

More information

CENTRAL UNIVERSITY OF JHARKHAND, RANCHI

CENTRAL UNIVERSITY OF JHARKHAND, RANCHI CENTRAL UNIVERSITY OF JHARKHAND, RANCHI (A Central University established by an Act of Parliament in 2009) Ref no. CUJ/ P&S/EE/266/24 Dated:23-04-24 Sealed quotations are invited for the article enclosed

More information

INVITATION FOR QUOTATION. TEQIP-II/2015/GJ1G02/Shopping/M-EE-09

INVITATION FOR QUOTATION. TEQIP-II/2015/GJ1G02/Shopping/M-EE-09 INVITATION FOR QUOTATION TEQIP-II/2015/GJ1G02/Shopping/M-EE-09 02-Dec-2015 Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for

More information

SPECIFICATIONS OF Ni-Cd BATTERY BANK

SPECIFICATIONS OF Ni-Cd BATTERY BANK SPECIFICATIONS OF Ni-Cd BATTERY BANK ANNEXURE-Z Supply, Installation and commissioning of Ni-cd battery bank for high rate of discharge type KPH 125V 210 AH consisting of 103 number of cells. Detail technical

More information

TECHNICAL SPECIFICATIONS FOR 11KV AIR BREAK (A.B.) SWITCHES :

TECHNICAL SPECIFICATIONS FOR 11KV AIR BREAK (A.B.) SWITCHES : TECHNICAL SPECIFICATIONS FOR 11KV AIR BREAK (A.B.) SWITCHES : 1. SCOPE : This specification covers design, manufacturing, testing at manufacturer s works, inspection, packing & delivery of 11 KV Air Break

More information

File No. EL/EE/NAD/Tech/1-13/2018/822 Dated: 29/08/2018 OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR

File No. EL/EE/NAD/Tech/1-13/2018/822 Dated: 29/08/2018 OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR Unique No.* Name of Work Name of Department Tender No.* Complete Mechanical works, Electrical works, Body works,

More information

INVITATION FOR QUOTATION. TEQIP-III/2018/gcej/Shopping/50

INVITATION FOR QUOTATION. TEQIP-III/2018/gcej/Shopping/50 INVITATION FOR QUOTATION TEQIP-III/2018/gcej/Shopping/50 15-Sep-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the

More information

INDUSTRIAL HAUL AGREEMENT

INDUSTRIAL HAUL AGREEMENT INDUSTRIAL HAUL AGREEMENT PUBLIC WORKS MEMORANDUM OF AGREEMENT entered into this day of, A.D., 20(yr). BETWEEN: PARKLAND COUNTY a County incorporated under the laws of the Province of Alberta, (hereinafter

More information

FLOAT CHARGER (40A) & BOOST CHARGER (35A) FOR NO BREAK POWER SUPPLY SYSTEM WITH REQUIREMENT FOR SCADA

FLOAT CHARGER (40A) & BOOST CHARGER (35A) FOR NO BREAK POWER SUPPLY SYSTEM WITH REQUIREMENT FOR SCADA GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR FLOAT CHARGER (40A) & BOOST CHARGER (35A) FOR GETCO/E/TS-50V BCHR(SCADA)

More information

FLOAT CHARGER & BOOST CHARGER F O R NO BREAK POWER SUPPLY SYSTEM (Float 100A & Boost 60 A with SCADA application)

FLOAT CHARGER & BOOST CHARGER F O R NO BREAK POWER SUPPLY SYSTEM (Float 100A & Boost 60 A with SCADA application) GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR FLOAT CHARGER (100A) & BOOST CHARGER (60A) FOR WITH REQUIREMENT FOR SCADA

More information

Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura Diesel Generator Required on Rental Basis

Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura Diesel Generator Required on Rental Basis Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura - 586109 Diesel Generator Required on Rental Basis Bank desires to hire diesel generator on rental basis for the following

More information

No. TE/F-814/16/WO- 145/ Dt

No. TE/F-814/16/WO- 145/ Dt No. TE/F-814/16/WO- 145/ Dt. 30.11.2016 To M/s Jaikar Techno Private Limited Plot No. 43, Near Imam Kothi, Old Hazaribagh Road, Kokar, Ranchi - 834009 Dear Sir, Sub : Work order for the work of Renewal

More information

NIT No.:-10/WEX/MCR/HYD. PRESS/2-303/ /Dt

NIT No.:-10/WEX/MCR/HYD. PRESS/2-303/ /Dt Annexure-1 NIT No.:-/WEX/MCR/HYD. PRESS/2-303/21-12/Dt.02.03.22 Name of work:-retrofitting of new hydraulic power pack on 63 Ton Hydraulic Press, Plan No.1/2-303 SCOPE OF SUPPLY AND WORK: 1.0 Purpose of

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR SELECTIVE LEVEL METER GETCO/E/TS- PACC SLM 03504/R0, Dt: 2.04.2008 Page

More information

NOTICE INVITING QUOTATIONS

NOTICE INVITING QUOTATIONS MALAVIYA NATIONAL INSTITUTE OF TECHNOLOGY JAIPUR No. F5(4020)ST/MNIT/Estate/2017 Phone : 0141-2713312,2713352 M/s......... NOTICE INVITING QUOTATIONS 1 Fax No. : 0141-2529078 1. Registrar, MNIT, Jaipur

More information

IMPORTANT NOTE (C) SENIOR ADVISER(CONTRACT & PURCHASE), OIL INDIA LIMITED, PLOT NO. 19 SECTOR 16A NOIDA

IMPORTANT NOTE (C) SENIOR ADVISER(CONTRACT & PURCHASE), OIL INDIA LIMITED, PLOT NO. 19 SECTOR 16A NOIDA IMPORTANT NOTE BID DOCUMENT HAS BEEN DISPLAYED TO UNDERSTAND THE REQUIREMENT ONLY. PARTIES INTERESTED TO PARTICIPATE AGAINST THIS TENDER SHALL HAVE TO PURCHASE THE TENDER DOCUMENTS FROM ANY OF OIL S DESIGNATED

More information

TECHNICAL SPECIFICATION FOR SUPPLY OF LT DISTRIBUTION KIOSK FOR 250/315 KVA & 63/100 KVA RATING DISTRIBUTION TRANSFORMERS AGAINST TN-2077

TECHNICAL SPECIFICATION FOR SUPPLY OF LT DISTRIBUTION KIOSK FOR 250/315 KVA & 63/100 KVA RATING DISTRIBUTION TRANSFORMERS AGAINST TN-2077 spec- 200 Amp. & 400 Amp. LT Dist. Kiosk.doc - 1 - SCHEDULE-III TECHNICAL SPECIFICATION FOR SUPPLY OF LT DISTRIBUTION KIOSK FOR 250/315 KVA & 63/100 KVA RATING DISTRIBUTION TRANSFORMERS AGAINST TN-2077

More information

TECHNICAL SPECIFICATION FOR 30 V, 100 AH STATIONARY BATTERIES AND BATTERY CHARGING EQUIPMENT. (SPECIFICATION NO. MSEB/Dist/IV/2004.

TECHNICAL SPECIFICATION FOR 30 V, 100 AH STATIONARY BATTERIES AND BATTERY CHARGING EQUIPMENT. (SPECIFICATION NO. MSEB/Dist/IV/2004. TECHNICAL SPECIFICATION FOR 30 V, 100 AH STATIONARY BATTERIES AND BATTERY CHARGING EQUIPMENT (SPECIFICATION NO. MSEB/Dist/IV/2004.) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 18

More information

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL. Estimation and Costing & Utilization of Electrical Energy

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL. Estimation and Costing & Utilization of Electrical Energy 1 SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL Estimation and Costing & Utilization of Electrical Energy Estimation and Costing & Utilization of electrical Energy Estimation

More information

Pre-Qualification- Cum Bid Notice

Pre-Qualification- Cum Bid Notice Pre-Qualification- Cum Bid Notice BANK OF BARODA, Baroda Corporate Centre, C-26, G Block, Bandra Kurla complex, Bandra (East), MUMBAI 400051 (Email - em.bcc@bankofbaroda.com) invites sealed bids for supply

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS. 110 V, 100 Ah / 250 Ah & 220 V, 250 Ah / 350Ah TUBULAR LEAD ACID BATTERY SETS

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS. 110 V, 100 Ah / 250 Ah & 220 V, 250 Ah / 350Ah TUBULAR LEAD ACID BATTERY SETS GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR 110 V, 100 Ah / 250 Ah & 220 V, 250 Ah / 350Ah TUBULAR LEAD ACID BATTERY

More information

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH 1.0 SCOPE:

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone:

More information

(ISO 9001 CERTIFIED)

(ISO 9001 CERTIFIED) (ISO 9001 CERTIFIED) TENDER ENQUIRY FOR PROCUREMENT OF BULLET PROOF JACKET To Subject: TENDER ENQUIRY NO. 04/LP/2018-19/BPJ-2000/WIL-dt. 11-10-2018. You are requested to submit your quotations for the

More information

AIRPORTS AUTHORITY OF INDIA OFFICE OF THE AIRPORT DIRECTOR ल. ग. ब. हव ई L G B I AIRPORT, GUWAHATI TECHNICAL DIRECTORATE क ट शन

AIRPORTS AUTHORITY OF INDIA OFFICE OF THE AIRPORT DIRECTOR ल. ग. ब. हव ई L G B I AIRPORT, GUWAHATI TECHNICAL DIRECTORATE क ट शन AIRPORTS AUTHORITY OF INDIA OFFICE OF THE AIRPORT DIRECTOR ल. ग. ब. हव ई L G B I AIRPORT, GUWAHATI TECHNICAL DIRECTORATE क ट शन Notice inviting Quotation Document No.AAI/GHT/E&M-01(Tyres) क लए व हन -,

More information

ARAI/TA(4G_RV)/HORIBA/MEXA 584L/ Dated 25 Mar 2014

ARAI/TA(4G_RV)/HORIBA/MEXA 584L/ Dated 25 Mar 2014 CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES M/s Horiba India Pvt. Ltd. Room 1521, 15 th Floor, Eros Corporate Tower, Nehru Place New Delhi 110 019 Cert Annex Drg Total 1 7 0 8 pgs Exhaust

More information

TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES:

TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES: TECHNICAL SPECIFICATION FOR 11 KV AIR BREAK (A.B.) SWITCHES: 1. SCOPE : This specification covers design, manufacturing, testing at manufacturer s works, inspection, packing & delivery of 11 KV Air Break

More information

7 The revised IS 8034:2002 and revised STI be implemented w.e.f. 1 Feb 2005.

7 The revised IS 8034:2002 and revised STI be implemented w.e.f. 1 Feb 2005. BUREAU OF INDIAN STANDARDS (CENTRAL MARKS DEPARTMENT-III) Our Ref: CMD-III/16:8034 25 Oct 2004 Subject: Implementation of revised IS 8034:2002 Submersible Pump Sets and revised STI (Doc:STI/8034/5 ) IS

More information

ARAI/TA(4G_RV)/SMS/D680/ Dated 21 st Mar 2015 CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES

ARAI/TA(4G_RV)/SMS/D680/ Dated 21 st Mar 2015 CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES M/s SMS Autoline Equipments Pvt. Ltd. Plot No.AP215, 6 th Street, I Block, Vallalar Colony, Anna Nagar (West) Chennai 600 040 Cert Annex Drg

More information

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet. SHEET 1 OF 5 1.0 GENERAL & SCOPE 1.1 This specification covers the design, material, construction features, manufacture, inspection & testing, Painting and packing requirements of Spring Loaded Bypass

More information

STR-1415 SPECIFICATION FOR BATTERY CHARGERS 220V, 30A FOR SUBSTATIONS ANNEXURES B

STR-1415 SPECIFICATION FOR BATTERY CHARGERS 220V, 30A FOR SUBSTATIONS ANNEXURES B STR-1415 SPECIFICATION FOR BATTERY CHARGERS 220V, 30A FOR SUBSTATIONS ANNEXURES B February 2017 STR-1415 SPECIFICATION FOR BATTERY CHARGERS 220V, 30A FOR SUBSTATIONS ANNEXURES B DRAFT FINAL DRAFT CONTRACT

More information

(i) in paragraph 9, for sub-paragraph (i) the following shall be substituted, namely:-

(i) in paragraph 9, for sub-paragraph (i) the following shall be substituted, namely:- Revision 3 Date: 28/01/2016 Amendment to Schedule 6 for Induction Motor In the said schedule, (i) in paragraph 9, for sub-paragraph (i) the following shall be substituted, namely:- Effective from 1 st

More information

CITY OF CHARLEVOIX REQUEST FOR BIDS WESTENBROEK SUBSTATION 48VDC BATTERY BANK

CITY OF CHARLEVOIX REQUEST FOR BIDS WESTENBROEK SUBSTATION 48VDC BATTERY BANK CITY OF CHARLEVOIX REQUEST FOR BIDS WESTENBROEK SUBSTATION 48VDC BATTERY BANK The City of Charlevoix is requesting bids for the furnishing and delivery (F.O.B. project material site, Charlevoix, Michigan)

More information

1. In these Terms and Conditions and unless the context otherwise requires:

1. In these Terms and Conditions and unless the context otherwise requires: DEFINITIONS 1. In these Terms and Conditions and unless the context otherwise requires: 1.1 Account Holder means the Principal Cardmember or Corporate Cardmember in whose name a Card Account has been opened

More information

RAJIV GANDHI UNIVERSITY OF KNOWLEDGE TECHNOLOGIES BASAR Nirmal District, Telangana Ref: RGUKT-B/Proc/Elec,Maint/Q08/2018, dated

RAJIV GANDHI UNIVERSITY OF KNOWLEDGE TECHNOLOGIES BASAR Nirmal District, Telangana Ref: RGUKT-B/Proc/Elec,Maint/Q08/2018, dated RAJIV GANDHI UNIVERSITY OF KNOWLEDGE TECHNOLOGIES BASAR Nirmal District, Telangana -504107 Ref: RGUKT-B/Proc/Elec,Maint/Q08/2018, dated. 17.12.2018 NOTICE INVITING QUOTATIONS Description : Supply of Electrical

More information

Tender Document for. NAME OF THE SUPPLIER / MANUFACTURER: NREDCAP Registration No: /

Tender Document for. NAME OF THE SUPPLIER / MANUFACTURER: NREDCAP Registration No: / Tender Document for Supply of around 50,000 Nos of Solar Lanterns to the P.O, ITDA's of West Godavari, East Godavari, Visakhapatnam, Vizianagaram and Srikakulam Districts for distribution to all S.T students

More information

INVITATION FOR TENDER FOR SUPPLY OF SOLAR PV SYSTEMS

INVITATION FOR TENDER FOR SUPPLY OF SOLAR PV SYSTEMS INVITATION FOR TENDER FOR SUPPLY OF SOLAR PV SYSTEMS Sealed tender offers are invited in two separate sealed covers (Technical and Commercial offers) from eligible manufacturers/suppliers or their direct

More information

Individual Fuel Card Application Form

Individual Fuel Card Application Form Individual Fuel Card Application Form INDIVIDUAL FUEL CARD APPLICATION FORM PART 1: AUTHORISED APPLICANT S DETAILS Full Name, Underline Surname (As in IC/Passport): Mr Ms Mrs Mdm Dr NRIC / FIN / ID / Passport

More information

SPECIFICATIONS OF ITEMS ANNEXURE-1A Sr. No. Item specification Qty. (in nos.) 1 Computer chair with armrest Approximate Size: Width 64 cm Depth 64cm Height 81.0-93.5 cm Seat Height 42-54.5 as Godrej Model

More information

Tender Enquiry No: BCL / PUR / ARC / AC&DC Motors/ CW / 2019 Dated: Due on:

Tender Enquiry No: BCL / PUR / ARC / AC&DC Motors/ CW / 2019 Dated: Due on: MINISTRY OF RAILWAYS HEAD OFF. & REGD. OFF. : 5, HIDE ROAD, KOLKATA 700 043 TEL: +91 33 2439-7415, 2439-4114, 2439-6613, 2439-7413, FAX: +9133 2439 7632/ 5607 E-mail: purchase@braithwaiteindia.com Website:

More information

ARAI/TA (4G)/AIRVISOR/AVG500/ Dated 17 th Apr 2017

ARAI/TA (4G)/AIRVISOR/AVG500/ Dated 17 th Apr 2017 Airvisor Technologies Pvt. Ltd. H-155, Adhyapak Nagar, Nangloi, New Delhi 110041. CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES Cert Annex Drg Total 1 7 0 8 pgs Exhaust Gas Analyzer Model

More information

Open Tender Enquiry OUTSOURCING OF PHOTOCOPY WORK AT SCOOTERS INDIA LIMITED SINGLE BID SYSTEM. SCOOTERS INDIA LIMITED Page 1

Open Tender Enquiry OUTSOURCING OF PHOTOCOPY WORK AT SCOOTERS INDIA LIMITED SINGLE BID SYSTEM. SCOOTERS INDIA LIMITED Page 1 Open Tender Enquiry OUTSOURCING OF PHOTOCOPY WORK AT SCOOTERS INDIA LIMITED SINGLE BID SYSTEM SCOOTERS INDIA LIMITED Page 1 THIS PAGE INTENTIONALLY LEFT BLANK SCOOTERS INDIA LIMITED Page 2 SCOOTERS INDIA

More information

شركة كهرباء محافظة القدس المساهمة المحدودة

شركة كهرباء محافظة القدس المساهمة المحدودة Our Ref: Date: Messrs. Dear Sir, Tender 22/2017 (re-bidding) 11& 33Kv Fuse Cutouts and Links You are kindly requested to bid for supply and delivery (DDP) for the medium voltage overhead line accessories

More information

SECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENT AND QUANTITIES

SECTION 1 SCOPE, SPECIFIC TECHNICAL REQUIREMENT AND QUANTITIES Tamil Nadu Transmission Corporation Limited Bharat Heavy Electricals Limited 400/110 KV Substation at Thappagundu & 400/230-110 KV Substation at Anikadavu, Technical specification for 420/245/132kV Isolators

More information

/ I S S : / S T S I

/ I S S : / S T S I Agenda Electrical Transformers (Quality Control) Order Obtaining BIS Licence Requirements of Guidelines / IS 1180-1: 1: 2014 / STI Concerns in Getting BIS Licence Experience with BEE Regulations Recommendations

More information

I N D I A N S T A T I S T I C A L I N S T I T U T E

I N D I A N S T A T I S T I C A L I N S T I T U T E I N D I A N S T A T I S T I C A L I N S T I T U T E 8 th MILE POST, MYSORE ROAD, BANGALORE Tel : 080 28483002-28483006, Fax 080 22293517, E-mail : isib@isibang.ac.in TENDER DOCUMENT FINANCIAL BID (SUPPLY,

More information

RU BMS Power Supply and Battery Management System Owners Guide

RU BMS Power Supply and Battery Management System Owners Guide RU2-4012- BMS Power Supply and Battery Management System Owners Guide (These instructions are intended for use by a technician familiar with electronic products) RU2-4012- BMS is a continuous duty power

More information

TENDER DOCUMENT PART-II

TENDER DOCUMENT PART-II 1 NATIONAL BANK FOR AGRICULTURE AND RURAL DEVELOPMENT TAMILNADU REGIONAL OFFICE TENDER DOCUMENT PART-II (PRICE BID) Supply, Installation, Testing and Commissioning of 25 kva DG Sets with Acoustic Enclosure

More information

TECHNICAL BID T 3627

TECHNICAL BID T 3627 TECHNICAL BID T 3627 Supply of Mechanical Measuring Instruments for TMD-II OF UKAI TPS. Due on At 3.30 P.M. (if Possible) EMD paid YES / NO EMD D. D. No. Date : OR SSI / NSIC Certification Number : Duly

More information

TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators:

TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators: TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators: (1) SCOPE: This specification covers outdoor, open, drop out expulsion type fuse cut outs suitable for installation in

More information

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell -11 PURE LEAD PLUS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications 305-545 Watts per Cell FEATURES & benefits APPLICATIONS Data Centers Network Operations Centers Industrial

More information

SPICES BOARD (Ministry of Commerce & Industry, Govt. of India) Palarivattom.P.O. N H By Pass Kochi

SPICES BOARD (Ministry of Commerce & Industry, Govt. of India) Palarivattom.P.O. N H By Pass Kochi SPICES BOARD (Ministry of Commerce & Industry, Govt. of India) Palarivattom.P.O. N H By Pass Kochi 682025 Phone: 0484-2333603 Email: sbqelkochi@gmail.com REQUIREMENT OF UPS Systems and Batteries for Quality

More information

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata- 700106 NOTICE INVITING QUOTATION Sealed Quotations are invited from reputed suppliers

More information

Total Ex. Tax/VAT. (Rs.) (if any) in Rs. (Bought out/direct) length 587M 226M

Total Ex. Tax/VAT. (Rs.) (if any) in Rs. (Bought out/direct) length 587M 226M ORISSA POWER TRANSMISSION CORPORATION LIMITED Supply & Laying of 132 KV XLPE Double Circuit (4 cable per Circuit including one spare) underground 1000 Sq. mm annealed Copper XLPE EHV Cable with Associated

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY Phone: +91 431 257 79 38 Fax

More information

Dakshin Gujarat Vij Company Limited

Dakshin Gujarat Vij Company Limited Dakshin Gujarat Vij Company Limited CIN U40102GJ2003SGCO42909 Regd. & Corporate Office: Urja Sadan, Nana Varachha Road, Kapodara Char Rasta,Surat 395 006 C & R DEPARTMENT Phone No.: 0261 2506100-200-175

More information

BIHAR STATE POWER TRANSMISSION COMPANY LIMITED MANUFACTURING QUALITY PLAN -- BATTERY CHARGER. Quantum of Check / Sampling with basis

BIHAR STATE POWER TRANSMISSION COMPANY LIMITED MANUFACTURING QUALITY PLAN -- BATTERY CHARGER. Quantum of Check / Sampling with basis A. Section : RAW MATERIAL INSPECTION 1.0 ELECTRONIC COMPONENTS 1.1 RESISTORS (Metal Film, Wire Wound) 1.2 POTENTIOMETERS 1.3 CAPACITORS (Polystyrene, electrolytic) 1.4 TRANSISTORS 1.5 L E D 1.6 1.7 INTEGRATED

More information

Net +Plus Connection Code

Net +Plus Connection Code Net +Plus Connection Code LANKA ELECTRICITY COMPANY (PRIVATE) LIMITED 1.0 BACKGROUND The existing Net Metering Concept launched in the year 2010 noticed an exponential growth in the recent year and at

More information

KERALA STATE ELECTRICITY REGULATORY COMMISSION. NOTIFICATION Dated, Thiruvananthapuram 6 th August,2007

KERALA STATE ELECTRICITY REGULATORY COMMISSION. NOTIFICATION Dated, Thiruvananthapuram 6 th August,2007 KERALA STATE ELECTRICITY REGULATORY COMMISSION NOTIFICATION No.1/1/KSERC-2006/ Dated, Thiruvananthapuram 6 th August,2007 KSERC (Supply of Power from Captive Generating Plants to Distribution Licensees)

More information

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date:

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date: 10111. 4711M1 An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT ENQUIRY Corrigendum 1

More information

SPECIFICATION FOR AUTOMATIC PRIMING AND OPERATING SYSTEM FOR CENTRIFUGAL PUMPS.

SPECIFICATION FOR AUTOMATIC PRIMING AND OPERATING SYSTEM FOR CENTRIFUGAL PUMPS. DRAFT SPECIFICATION NO : RDSO/PE/SPEC/D/PS/0010-99 (REV. 0 ) SPECIFICATION FOR AUTOMATIC PRIMING AND OPERATING SYSTEM FOR CENTRIFUGAL PUMPS. 0. FOREWORD 0.1 This specification covers manufacturing and

More information

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV.CAPACITOR BANK 1.0 SCOPE: This specification covers

More information

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1.

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1. -1029 Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications. APPLICATIONS Data Centers Network Operations Centers Industrial Process Control Facilities Internet Housing Sites Semiconductor

More information

INVITATION TO TENDER MR 84/2016. SUPPLY and Install 110V DC BATTERY BANKS and CHARGERS for Rarawai, Sabeto and Lautoka Switching Station

INVITATION TO TENDER MR 84/2016. SUPPLY and Install 110V DC BATTERY BANKS and CHARGERS for Rarawai, Sabeto and Lautoka Switching Station INVITATION TO TENDER MR 84/2016 SUPPLY and Install 110V DC BATTERY BANKS and CHARGERS for Rarawai, Sabeto and Lautoka Switching Station Fiji Electricity Authority seeks reputable Manufacturer/Supplier

More information

31-SDMS-02 REV. 01 SPECIFICATIONS FOR

31-SDMS-02 REV. 01 SPECIFICATIONS FOR 31-SDMS-02 REV. 01 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PILLAR This specification is property of SEC and subject to change or modification without any notice C O N T E N T S S. NO. D E S C R I P

More information

: Material Description Quantity UOM

: Material Description Quantity UOM Page : 1 / 2 OIL INDIA LIMITED (A Govt. Of India Enterprise) Tel :033 2230 1657, 1658 4, India Exchange Place, Fax :91 33 2230 2596 Kolkata-700001 E-mail :oilcalmn@cal2.vsnl.net.in ANNEXURE-I Item No./

More information

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT 1.0 PURPOSE: 1. To charge the battery bank through Solar PV source and AC supply. 2. To invert and produce utility quality sine wave. 3. Inverters

More information

ARAI/TA(4G)/SMS/D680/ Dated 28 Jan 2010

ARAI/TA(4G)/SMS/D680/ Dated 28 Jan 2010 CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES M/s SMS Autoline Equipments Pvt. Ltd. Plot No.AP215, 6 th Street I Block, Vallalar Colony, Anna Nagar (West) Chennai 600 040 Cert Annex Drg

More information

TENDER DOCUMENT BHARAT HEAVY ELECTRICALS LIMITED, HEEP, RANIPUR, HARIDWAR

TENDER DOCUMENT BHARAT HEAVY ELECTRICALS LIMITED, HEEP, RANIPUR, HARIDWAR TENDER DOCUMENT Retrofitting of 10 MT hand operated overhead crane by Electric Wire Rope Hoisting Trolley NIT No.: WEX/SP/COMP/CRANE/11-12 Dated: 07.01.2012 BHARAT HEAVY ELECTRICALS LIMITED, HEEP, RANIPUR,

More information

Pure Lead-Tin Technology

Pure Lead-Tin Technology Pure Lead-Tin Technology Pure Lead-Tin technology offers many advantages which include: High overall efficiency High energy density Excellent high rate performance Excellent low temperature performance

More information

MGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:-

MGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:- MGVCL//11KV D.O.FUSE/SPECIFICATIONS -:11KV DROP OUT FUSE CUTOUTS:- 01) SCOPE: This specification covers outdoor, open, drop out expulsion type fuse cut outs suitable for installation in 50Hz, 11KV distribution

More information

Material Description Quantity UOM

Material Description Quantity UOM Page : 1 / 8 OIL INDIA LIMITED Fax-91 0361 2643686 (A Govt. of India Enterprise) Email-oilmatpl@oilindia.in Udyan Vihar, Narengi, Guwahati, Assam 10 99070701 BATTERY 12 V 65AH Sealed Maintenance Free (SMF)

More information

Reference Number PDS 18 - (RIC Standard: EP SP)

Reference Number PDS 18 - (RIC Standard: EP SP) Discipline Engineering Standard - NSW Category Electrical Title Reference Number PDS 18 - (RIC Standard: EP 06 00 00 01 SP) Document Control Status Date Prepared Reviewed Endorsed Approved Jan 05 Standards

More information

D.C. DISTRIBUTION BOARD

D.C. DISTRIBUTION BOARD PRAMBL: The TC is maintaining 50-volt battery backup system for the PLCC communication. The 50-volt D.C. supply from the Float cum Boost charger is brought to D.C. Distribution Board from where supply

More information

CORRIGENDUM. Page 1 of 16

CORRIGENDUM. Page 1 of 16 CORRIGENDUM In the light of pre-bid meeting held on 27.07.2018 (Friday) at 1.00 P.M. & suggestions received from the prospective bidders, JREDA has decided to make following amendments/addendum in the

More information

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell UPS 12-1121 PURE LEAD PLUS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications 305-545 Watts per APPLICATIONS Data Centers Network Operations Centers Industrial Process Control

More information

Umatilla Electric Cooperative Net Metering Rules

Umatilla Electric Cooperative Net Metering Rules Umatilla Electric Cooperative Net Metering Rules Version: July 2017 Umatilla Electric Cooperative NET METERING RULES Rule 0005 Scope and Applicability of Net Metering Facility Rules (1) Rule 0010 through

More information