A VIETNAMESE MEMBER OF A WORLD - WIDE FAMILY

Size: px
Start display at page:

Download "A VIETNAMESE MEMBER OF A WORLD - WIDE FAMILY"

Transcription

1

2 A VIETNAMESE MEMBER OF A WORLD - WIDE FAMILY ABB Ltd. ABB Ltd. was originally a Joint Venture Company, ABB Transformers Ltd., between the Vietnamese transformers manufacturer CTBT, affiliated with Ministry of Industry, and the international electrotechnical group ABB. It has been in operation since 1 September CTBT's local experience and knowledge combined with ABB's technical and managerial expertise will lift the transformer quality up to an international standard and bring Vietnam into the family of developed countries within transformer engineering. ABB transformers factory located in Tanh Tri, just outside Hanoi. Now it is producing distribution transformers up to 16MVA, 35kV. In 1999, with the addition of the power transformers division, the factory started manufacturing power transformers up to 100MVA and 110kV 2

3 Saving energy is valuable Decades of economy Transformers are capital goods with In order to determine the most It is more difficult to evaluate load a life expectancy for decades. For economical design for the losses because they increase and this reason the buyer should not only respective application it is important decrease quadraticly with the load. consider the initial costs of the to know which capitalized value The lower limit of the load-loss transformer but also the estimated results from determined losses. This evaluation, however, is easily maintenance costs as well as the value can then be set in relation to ca lc ul at ed be ca us e on ly th e Costs of no-load losses of the iron the initial cost. Higher initial costs constant factor, determined by the cor e an d lo ad l oss es o f th e caused by increased amount of core energy cost, is taken into windings. steel and winding materials result in consideration a price range of USD lower operating costs. from 0.56 to 1,3 per watt. The Evaluating no-load losses is average value is from approx. USD relatively simple because they per watt. accrue at a constant rate during the Shows a model evaluation based on total operating time of 8760 hours various realistic assumptions. It annually. The values fluctuate proves that it pays to use ABB oil between. USD 4-10 per watt, transformers with reduced losses. depending on local. The average In the event of special operating Evaluated load losses price is approx. USD 6 per watt. But conditions and electricity costs one it must be evaluated for each must deviate from the values given country transformers with reduced in the selection tables. Optimized no-load losses are recommendable, designs which meet individual capitalized value 0 P/P N (fixed energy costs) evaluated No-load losses Initial costs 0,2 0,4 0,6 0,8 1,0 1,2 Principle diagramm (400 kva) capitalized value vs. P/P characteristic N ABB oil transformers are manufactured of only the highest quality materials and by the most modern and reliable methods. Thus the transformers are of a high availability and require small maintenance. And therefore hermetically sealed transformers is standard for all. ABB transformers in the range from 31,5, kva to 2000 kva on request. too, because therewith is associated a reduction of noise emission. requirements are available and are delivered on request. Example of a capitalized value comparison for 400 kva Initial costs KA No - load losses Po Load losses Pk Loss evaluation no - load losses Loss evaluation load losses KPo = 6 USD/watt x Po KPk = 0,56 USD/watt x Pk Variant I Variant II Variant III Variant IV USD 6 per watt USD 0,56 per watt PO Pk KA KPo KPK Totai in W W USD USD USD USD Stacking Core

4

5 Factory ABB Ltd produce transformers and other electrotechnical prod- ucts in the previous CTBT factory in Thanh Tri, outside Hanoi. The distribution transformer factory has been totally renovated, lifting capacity is increased and working environment improved. After renovation the buildings are of a standard comparable with other ABB factories around the world. Almost all present machinery and equipment has been replaced by imported ones. This is necessary The ABB transformers are designed to withstand a direct short circuit across the terminals. Short circuit tests to demonstrate the transformers abilities to withstand thermal and mechani- cal stress during short circuits have successfully been performed in many different laboratories in accordance with IEC procedure. to meet our requirements for international quality and productivity. Special attention is paid to test equipment and facilities giving customers reliable testing and quality control of the products they buy from us. Standards. The ABB distribution transformers are produced and tested accord- ing to IEC Publication 76. General Design. Product and design engineering is the well - proven and international recognized ABB technology used world-wide. The transformers are three-phase, oil immersed with ONAN cooling, for indoor and outdoor installation. They are available in ratings from 31,5 kva to kva and maximum voltage 36 kv. The transformers can either be hermetically sealed or free breathing with conservator. The special winding design gives a uniform impulse voltage distribu- tion, and guarantees ability to withstand lightning overvoltages. The ABB transformers can be overloaded in accordance with IEC Publication 354 "Loading guide for oil immersed transform- ers. 5

6 Optimum core The core Consists of cold-rolled, grainoriented magnetic sheets of the highest quality. The most advantageous transfer of the magnetic flux from legs to yoke is achieved by overlapping the opposing - joints on neighbour sheets. In some cases they are staggered several times. The cutting angle generally 0 amounts to 45 These provisions reduce the values of no-load losses and no-load currents as well as of the noise and increases the mechanical solidity. The cutting line with Computer controled Cross-sections of yokes and legs are nearly round due to the staggered width of the sheets. The core are cut in an automatic cut-to-length equipment. The legs and the lower yoke are laid in a special device. After mounting the coils the insertion of the upper yoke follows. Stacking Core 6

7 Reliable windings For almost two decades an impulsevoltage and short-circuit proof combination of LV foil winding and HV layer winding has proved in ABB distribution transformers. For economic reasons electrolytic copper is used as conductor material. LV foil winding Transformers with rating 160 kva and higher have low voltage winding made of copper foil which reduces load losses and eliminates axial forces during short circuits, thus increasing the mechanical strength of the transformers dramatically. In transformers with lower ratings where stray losses and mechanical stress during short-circuit are less critical, conductors of paper insulated copper wire are used. HV layer winding Making a LV foil wingding The high voltage winding is of the multilayer type, which ensures a uniform voltage distribution of lightning overvoltages, resulting in improved dielectric strength. The conductors are made of copper and are either enameled or paper insulated. A special type of epoxy diamond dotted Kraft paper with high mechanical and electric strength is used as insulation between layers. Connections from the coil taps to the bushings and to the tap-changer are made by contact crimped copper leads. Making a HV layer wingding 7

8 Top quality materials The tanks. The tanks are made of corrugated steel plates. The tanks are of the hermetically sealed type, which totally prevents moisture from the air being absorbed in the oil thus increasing long term dielectric strength and reducing oxidation of the oil the cooling fins are designed to take up the expansion during operation. Tanks and covers are sand-blasted phosphated and electrostatically painted with a polyester powder paint. This is resistant to atmospheric aging and UV light, giving an excellent and durable protection against corrosion. Foiling the tank fins The cover Is bolted to the tank and standardized bushings are fixed to the cover by studs. The conservator depend on request of customer for over 2000 kva is equipped with a magnetic oil level indicator and a filling/venting plug. Corrosion protection Corrosion protection Makes an important quality feature of ABB transformers. To the cleaned and prepared surface an active primer. The applied coats are forming a specific coordinated system tested by wellknown power suppliers. 8

9 Reliable processing The core-coil assembly Occurs in a production line in which the cores are carried to the mounting stations. After the HV and LV coils are mounted and centred the upper yoke is stacked and the core-coil clam-ping device is fixed. The cover is also bolted to the upper clamping. The HV winding leads are insulated with paper tubings and brazed I Crimped to the connection of the bushings resp of the tap changer. The HV leads are insulated against the upper clampings by a press board panel, while an additional panel fixes the position of the Leads. Drying and Oil Filling All transformers are dried by elevated temperature, and then filled under vacuum with dried and degassed oil. By this process the risk for reduced dielectric strength due to moisture and air inclusions in the insulation is eliminated. All transformers are shipped with oil and shall not be opened for inspection after they have left the factory. The mineral oil used in the transformers complies with IEC Publication 296 Assembling the windings Assembling the electric part Vacuum drying Mouting the untanking part 9

10 Accessories for ABB distribution transfomers All demands met Tap changers can provide transformers with The trip contact is activated in The standard voltage regulation voltage switching between case of acute damages. All range is ± 2x2.5% but other ranges present distribution voltage and transformers from 1000 kva and can be supplied upon request. future 20kV network greater can be equipped Each transformer is equipped with Buchholtz relays additionally with a Buchholtz a five position off-load tap Protect the transformer against oil relays without problem after the changer. The tap changer must loss and the results of thermal adaptor has been removed. only be operated when the overload of the insulating Winding Temperature Indicator transformer is de-energized. We materials. The alarm contact in the Are used for indication of the are only using tap changer from double-float design indicates tem por ary oil tem per atu re. the leading suppliers in the world. degree of the oil level as well as Contacts for alarm and trip signals By using tap changers and special al re ad y l it le ge me ra ti on of ca n b e a dd ed as ov er lo ad high voltage winding design, we decomposition gases. protector. Tap changer Oil level indicator for Transformer with conservator Oil level indicator for hermetical sealed type Oil level indicator with contacts Double-float Buchholtz Relays Winding Temperature indicator 10

11 Evidence of quality By the routine test All transformers are tested according to IEC Publication 76, specifying following routine tests: -Ratio polarity and vector group measurement. -Measurement of winding resistance -Measurement of load losses and impedance voltage. -Measurement of no load losses and no load current. -Induced overvoltage withstand test. -Separate source voltage withstand. On request the following type tests canbe conducted: -Heat run test. -Noise measurement. The temperature rise Of the windings is measured by a type test. At that the average winding temperature in accordance with insulation class A must not exceed a value of above ambient temperature. The short-circuit resistance Is verified by special tests and, on request of the Noise measuring customer. Done by well-known test laboratories. Many years of test experience and good operating experien of the customers have confirmed the efficiency The noise levels Are less than those permitted by IEC - 76 The impulse-voltage resistance of components and of complete transformers is verified in the test laboratory by type tests and random sample tests. Testing room 11

12 Custom made for your requirement ABB distribution transformers are = 36 kv on the HV winding, Um = well as supplementary customer manufactured acc. to IEC-76 and 0,4 kv on the LV winding, as well needs for accessories and the up-to-date "Technical terms of as a frequency Of 50 Hz and connections. Maintanance of delivery of transformers". These continuous operation with natural hermetically sealed transformers rules pertain to oil-filled threeis less frequent because the cooling. phase transformers with a rated The combination of series parts power of kva; a and design groups enables to insulation does not come in maximum operating voltage of Um meet international regulations as contact with the ambient air. 12

13 After - sales service Machine - made repair/overhaul of transformers of different producers Main points of repair / overhaul. - Cleaning and corrosion removal - Arrival test acc. to IEC-76 and state recording. - Waste oil disposal. - Dismantling of the transformer. - Cleaning, checking, and fault removing on the core-coil assembly. - Revision of the tap-changer. - Stove drying of the core-oil assembly. - Mounting the transformers with change of all seals. - New-oil filling and evacuation of the transformer. - Final test with test report acc. to IEC-76 and fixing an overhaul rating plate. - Surface treatment by flooding process. - Pressure test for tightness. 13

14 After - sales service Additional services - Manufacture of new tanks and adequate reconstruction. - Manufacture of new conservators and their mounting. - Manufacture of new windings (for own products) at electric failures depending on the year of construction. - Reconstruction of the terminal technique to IEC version, all variants of plug-in technique. - Reconstruction to the desired equipment, for example magnetic oil-level gauge. Buchholtz relay, dial thermometer, oil level Indicator for hermetic design and so on. l Repair on site: Sealing works change of accessories, adjusting of oil level, exchanging of different bushing systems (plug-in technique) l Transport: Taking over of all transport services with customers' requirements l Analyses: Oil check for PCB-content, breakdown response and tang-δ-measurement, winding test expert opinion on transformers fault reports. l Replacement supply: Providing of substitute transformers during the period of repair (lf present on stock) to replace damaged one. l Spare-part supply: Holding instock accessories bushings, seals and so on. l Machine-made repair / overhaul of transformers of different producers l Documentation: Holding available of test records also for transformers already delivered acc. to IEC-76, service instructions prospectures. Your special inquiries for all further problems of repair and service please address to our after-sales-service office 14

15 ABB IN VIETNAM ISO 9001:2000 UKAS QUALITY MANAGEMENT HANOI ABB HEAD OFFICE ABB INDUSTRY CO.,LTD TCVN :1997 ABB LTD. IE C 7 6 : WE ARE AT YOUR DISPOSAL Our entire programme We produce: - Oil transformers up to 63 MVA, service voltage up to kv in accordance with all the relevant standards and in special designs. - On-load regulating transformers with on-load tap-changer. - Pole-mounted transformers. - Earthing transformers. - Dry type transformers, in insulation class F for power station applications. - Rectifier and furnace transformers BRANCH OFFICE DA NANG Repairs: Transformers and electrical machinery of all kinds and makes up to 63 MVA; production of complex replacement windings; acceptance of PCB-filled transformers for disposal. HO CHI MINH CITY BRANCH OFFICE ABB Ltd. DISTRIBUTION TRANSFORMERS DIVISION Milestone No 9, National Highway No1 Hoang Liet, Thanh Tri, Hanoi, Vietnam Telephone: (+84.4) Fax: (+84.4)

Distribution transformers Efficiency over life-cycle

Distribution transformers Efficiency over life-cycle Distribution transformers Efficiency over life-cycle ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while

More information

ABB Transformers Egypt

ABB Transformers Egypt Kamel Elhamy, 2013 ABB Transformers Egypt Our transformers support the systems that keep our world running ABB January 31, 2012 Slide 1 Factory Information Key data 2012 Annual volume 40 MUSD Employees

More information

MEDIUM POWER TRANSFORMER

MEDIUM POWER TRANSFORMER MEDIUM POWER TRANSFORMER MEDIUM POWER TRANSFORMER FROM 3,15 TO 31,5 MVA HIGHEST VOLTAGE FOR MATERIAL 72,5kV GENERAL CHARACTERISTICS Three phase oil-immersed naturally cooled type ONAN medium power transformers.

More information

TRANSFORMERS UP TO 750 kv

TRANSFORMERS UP TO 750 kv Electric Co. Ltd. TRANSFORMERS UP TO 750 kv CONTENTS General... 2 Products... 3 Construction...4 Magnetic core... 4 Windings...5 Frame structure... 6 Connections...6 Tap changer and motor drive...7 Tank...

More information

INESING GROUP. Power System Solution

INESING GROUP. Power System Solution INESING GROUP INESING GROUP Power System Solution Power System Solution INESING Group Via Dell'Industria 18B 24040 Casirate D'Adda Italy t: +39 3388263363 f: +39 04381890521 e: info@inesing.com introduction

More information

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers ABB PTTR SPAIN Zaragoza. The product: Cast coil transformers ABB BA Transformers - 1-5/7/2007 Dry Type Vacuum Cast Coil Transformer INTRODUCTION ABB BA Transformers - 2 - Product Portfolio II Dry Type

More information

ABB Ltd. FACTORY IN HANOI

ABB Ltd. FACTORY IN HANOI ABB LTD. ABB Ltd. was originally a JVC between the Vietnamese Transformers Manufacture CTBT and the International Electromechanical group ABB Company was established 1st Sep. 1994 Distribution Transformers

More information

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026 TECHNICAL PERTICULAR FOR 1.6 MVA 6.6/0.433 KV SERVICE TRANSFORMER 1.00.00 GENERAL 1.01.00 Service SERVICE 1.02.00 Make ASHOK/VOLTAMP/DANKE/CGL 1.03.00 Type CORE 1.04.00 Location OUTDOOR 1.05.00 Specification

More information

Power IT Liquid Filled Transformers. IEC standard, small and medium, rated power 2000kVA, HV 36kV

Power IT Liquid Filled Transformers. IEC standard, small and medium, rated power 2000kVA, HV 36kV Power IT Liquid Filled Transformers IEC standard, small and medium, rated power 2000kVA, HV 36kV Even our standard solutions are special In almost every place where people live and work you will find at

More information

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications Distribution The most comprehensive range of solutions for distribution transformer applications Oil Type Single-phase and three-phase transformers for the range above 16 kva and up to 72.5 kv. These units

More information

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA ITALY POLAND INDIA CENTRAL & SOUTH AMERICA

More information

Cast resin transformers

Cast resin transformers Product catalogue Cast resin transformers according to IEC/EN 60076, VDE 0532, DIN 42523 Power range up to 8 MVA Voltage range up to 36 kv Conductor material: copper or aluminum Protection types: IP 00

More information

Power and Distribution Transformers

Power and Distribution Transformers Power and Distribution Transformers VRT Power Ltd. We Enable Energy VRT is a modern manufacturer for high-performance oil-immersed power transformers up to 800 MVA 500 kv. Customized design and the development

More information

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards Minera Oil distribution transformers up to 3 150 kva Minera at a glance Mineral oil-immersed, 50 Hz, three-phase distribution transformers with the following characteristics: Hermetically sealed with integral

More information

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1 WeSTinghouse Descriptive Bulletin 47-156 Page 1 liquid Filled, Self-Contained 112% 2500 Kva June, 1974 Supersedes DB 47-350, dated August 1972 E, D, C/2082/DB Descriptive Bulletin 47-156 Page 2 Westinghouse

More information

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society Guideline No.: E-07(201712) E-07 TRANSFORMERS Issued date: December 26, 2017 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

CAST RESIN TRANSFORMERS

CAST RESIN TRANSFORMERS MODEL TAM CAST RESIN - TAM TYPE Epoxy cast resin dry-type transformers are recommended to operate in places that require security, the materials used in its construction are hard to combust and are self-extinguishable

More information

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open Substation Transformers Primary or Secondary Open GENERAL Cooper Power Systems Primary or Secondary Open Substation Transformers are designed to meet exact customer specifications. Flexibility in design,

More information

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers Certified for best-in-class performance, reliability, and safety Trihal sets a new standard for dry-type cast resin transformers Setting a new standard for dry-type cast resin transformers hospitals wind

More information

Fuji Electric. Oil immersed. Transformer FTU08A1-E-0024

Fuji Electric. Oil immersed. Transformer FTU08A1-E-0024 Fuji Electric Oil immersed Transformer 1 FTU08A1-E-0024 History Fuji Electric (T&D Business) 1923 Established Fuji Electric Manufacturing Co.,Ltd. 1962 Started operation of Chiba factory (transformer)

More information

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench

More information

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK 1ZSC563-AAA en, Rev. 2 Resin Impregnated Paper Bushing, Oil to SF 6, Type GSBK Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

Bushings for High Voltage AC Applications

Bushings for High Voltage AC Applications Bushings for High Voltage AC Applications Selection guide 1ZSE 2750-100 en, Rev. 3, 2006-03-15 During selection of for high voltage applications several important factors have to be considered to ensure

More information

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society Guideline No.: E-07(201610) E-07 TRANSFORMERS Issued date: October 28,2016 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide 1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets P2 : About Us P3 : Elsewedy Transformers P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers P7 : Technical Data Sheets P8 : Transformer s Outline Drawing P9 : Accessories About Us

More information

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society Guideline No.: E-07(201501) E-07 TRANSFORMERS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

TGK Prefabricated Substation Technical Data

TGK Prefabricated Substation Technical Data TGK Prefabricated Substation Technical Data Ref Item Data 1 General Technical 1.1 Frequency (Hz) 50 1.2 Transformer Rating (kva) 315/750 1.3 Transformer Primary Voltage (kv) 11 1.4 Transformer Secondary

More information

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st 2014 New RIS transformer bushings The paper-free solution Transformer condenser bushings Why a new technology? To preserve

More information

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide 1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide 1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover

More information

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical

More information

AC/DC Arc Furnace and Ladle Furnace Transformers

AC/DC Arc Furnace and Ladle Furnace Transformers AC/DC Arc Furnace and Ladle Furnace Transformers Specification parameter Specify the requirements for 1. Environmental condition and standards Applicable standard Electrical standard Mechanical standard

More information

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench

More information

Volt Instrument Transformers

Volt Instrument Transformers www. kuhlman. com Kuhlman Electric Corporation Instrument Transformers 1 Table of Contents Description Model Page Wound, Oil-Filled VT (High Accuracy available) UTE-145-OH 3-4 Wound, Oil-Filled CCVT (High

More information

/ I S S : / S T S I

/ I S S : / S T S I Agenda Electrical Transformers (Quality Control) Order Obtaining BIS Licence Requirements of Guidelines / IS 1180-1: 1: 2014 / STI Concerns in Getting BIS Licence Experience with BEE Regulations Recommendations

More information

B kv T&D GAS INSULATED SWITCHGEAR

B kv T&D GAS INSULATED SWITCHGEAR GAS INSULATED SWITCHGEAR B 105 170 300 kv The increasing demand for electrical power in cities and industrial centers necessitates the installation of a compact and efficient distribution and transmission

More information

Design specifications

Design specifications Design specifications Design To relevant standards: IEC, VDE, DIN, ISO, EN With squirrel-cage or slipring rotor Degree of protection IP 55 / IP 65 Cooling method IC511, suitable for both indoor and outdoor

More information

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS 1 TABLE OF CONTENTS ABOUT SVEL GROUP CAST-RESIN TRANSFORMERS ACCESSORIES AND OPTIONAL EQUIPMENT ENCLOSURE AND HOUSING TESTS AND QUALITY

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st 2014 Dry-type transformers Innovative Technology What is a dry transformer? ABB manufactures a transformer which does

More information

Kuhlman Electric Corporation Volt Instrument Transformers

Kuhlman Electric Corporation Volt Instrument Transformers Kuhlman Electric Corporation 46000 Volt Instrument Transformers 46000 Volt Table of Contents Description Model Page Wound, Dry-Type VT (High Accuracy available) U/VRU-52(H) 3-4 Wound, Oil-Filled VT (High

More information

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation MOBILE SUBSTATIONS Energy Solution INTERNATIONAL FAIR MOBILE SUBSTATIONS ENERGY SOLUTION Complete design for energy s generations, transmission and distribution Mobile Substations Applications of Inesing

More information

C. System Design and Performance Requirements

C. System Design and Performance Requirements Change History Date Description of Change Pages / Sections Modified 6/15/16 Updated division section from 16361-E-E to 26 10 03, removed references to other section numbers A. Summary - mgl44 Change Approver

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: 4 (Four) Pole Monoblock: Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: Designed and manufactured in accordance with EN 50336:2002 and BS 2562: 1979 1 Introduction:

More information

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00 CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00 1 HISTORY INESING SRL is a dynamic and modern company, very well known in the design and production of dry type (cast resin ) transformer up to 36kV -10MVA,

More information

AIR CORE REACTORS. Phoenix Electric Corporation

AIR CORE REACTORS. Phoenix Electric Corporation AIR CORE REACTORS Phoenix Electric Corporation PHOENIX ELECTRIC CORPORATION designs and manufactures Dry Type Air Core Reactors for operation on systems rated through 800 kv. All reactors are custom designed

More information

History of the company. TUMETIC and TUNORMA: Tailor-Made Technology

History of the company. TUMETIC and TUNORMA: Tailor-Made Technology History of the company Csepel Transformer Factory was founded in 1960 as a state owned company in the location of the large industrial estate in southern Budapest situated on the island of the Danube river.

More information

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability. GE Grid Solutions OTCF Capacitor Voltage Transformers 72.5 kv to 800 kv In high and extra high voltage transmission systems, capacitor voltage transformers (CVTs) are used to provide potential outputs

More information

Standard Features and Accessories

Standard Features and Accessories 14.0-12 Secondary Unit Substations Secondary Below 1000V Product Overview General Description December 2012 Sheet 14012 Liquid-Filled Substation Transformers Application Description Eaton s liquid-filled

More information

Technical Specification of GECOL. Packaged Transformers

Technical Specification of GECOL. Packaged Transformers GES 26211 Technical Specification of GECOL Packaged Transformers (Revision history) Issued on: Jan. 01, 2007 General Electricity Company of Libya Contents 1 SCOPE AND SERVICE CONDITIONS... 6 1.1 SCOPE...

More information

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit Substation Transformers Primary or Secondary Unit GENERAL Cooper Power Systems Primary or Secondary Unit Substation Transformers are designed to meet exact customer specifications. Flexibility in design,

More information

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction. HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After

More information

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement. INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side

More information

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION TMC TRANSFORMERS - GLOBAL NETWORK UK & IRELAND SPAIN NORTH AMERICA & CANADA GERMANY SWITZERLAND BENELUX & AUSTRIA CENTRAL & SOUTH AMERICA MIDDLE EAST &

More information

GAS INSULATED VOLTAGE TRANSFORMERS.

GAS INSULATED VOLTAGE TRANSFORMERS. GAS INSULATED VOLTAGE TRANSFORMERS. This document may be subject to changes. Contact ARTECHE NISSIN to confirm the characteristics and availability of the products described here. CONTENTS 1. Presentation

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

Prime Power Energie Systems Inc.

Prime Power Energie Systems Inc. Prime Power Energie Systems Inc. C a s t C o i l Tr a n s f o r m e r s 100 kva to 30 MVA 2 3kV tto 34 2.3kV 34.5kV 5kV Extraordinary Quality, Reliability and Service Energy Efficient Low Total Owning

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

LV Bushing Oil to Air Dry Insulation PTAB-SLV832 LV Bushing Oil to Air Dry Insulation PTAB-SLV832 Technical Guide 600 V, 30 kv BIL, 600-2500 A 5/8" Integral Flange Bushing 1.0" Integral Flange Bushing 1.25" Bushing General Description The ABB low voltage

More information

Power IT RESIBLOC Dry Type Distribution Transformers. 250 kva up to 40,000 kva

Power IT RESIBLOC Dry Type Distribution Transformers. 250 kva up to 40,000 kva Power IT RESIBLOC Dry Type Distribution Transformers 250 kva up to 40,000 kva Mission ABB is a global leader in power and automation technologies that enable utility and industry customers to improve

More information

ZREW Transformers Perfection in Detail. a company of Rauscher & Stoecklin SERW ZREW Tesar

ZREW Transformers Perfection in Detail. a company of Rauscher & Stoecklin SERW ZREW Tesar ZREW Transformers Perfection in Detail a company of Rauscher & Stoecklin SERW ZREW Tesar ZREW Your partner for high quality transformers A basic requirement for power transformers is a reliable and efficient

More information

Ventilated Distribution Transformers

Ventilated Distribution Transformers Ventilated Distribution Transformers The Energy Policy Act of 2005 (H.R. 6) requires Distribution Transformers manufactured after January 1, 2007 to meet specifi c energy effi ciency requirements. EPAct

More information

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances CONTENTS 1 GENERAL 2 STANDARDS 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances 4 MOTOR DESIGN 4.1 Stator Casing 4.2 Stator Core with Winding 4.3 Stator Winding 4.4

More information

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled 1500 kva Pad Mount Transformer - 24940GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled Part #: MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R Page: 1 The MT-PMO-3P-24940GRDY.14400-1500KVA-208Y.120-N3R

More information

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction. HHD HIGH VOLTAGE GERMAN DIN STANDARD FOR AIR & GAS INSULATED SWITCHGEARS OUTDOOR SWITCHGEARS The striker pin system is connected by means of a high resistance parallel conductor. After melting the main

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed. City of Cartersville Electric System P.O. Box 1390 320 S. Erwin St. Cartersville, GA 30120 770-387-5631 March 2006 SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS This specification provides standardization

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

Vacuum Cast Coil Dry Type Distribution Transformers. The reliability in your hands.

Vacuum Cast Coil Dry Type Distribution Transformers. The reliability in your hands. Vacuum Cast Coil Dry Type Distribution Transformers The reliability in your hands. ABB Vacuum Cast Coil dry transfomera leader in its category In almost every place where people live and work you will

More information

HPS EnduraCoil. Cast Resin Transformer

HPS EnduraCoil. Cast Resin Transformer HPS EnduraCoil Cast Resin Transformer Hammond Power Solutions Inc. (HPS) is a leading manufacturer of standard and custom dry-type transformers in North America. Every HPS product is built with the quality

More information

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide 1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

Unit Substation Transformers 5 and 15 KV Class

Unit Substation Transformers 5 and 15 KV Class Transformers 5 and 15 KV Class 85 General Information Description Federal Pacific unit substation transformers are available in a wide variety of types and ratings to provide reliable and versatile electrical

More information

Transformers Global product offering

Transformers Global product offering Distributor Line Card Transformers Global product offering ABB is a major transformer manufacturer throughout the world and offers both liquid-filled and dry-type transformers as well as services for complete

More information

Padmount. Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage

Padmount. Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage Padmount Small Power Transformers 2500 kva Through 20,000 kva 5 kv Through 46 kv Primary Voltage 120V Through 25 kv Secondary Voltage ABB s Padmounted Transformers provide tamper-resistant protection in

More information

*(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56

*(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56 T *(1(5$/7(&+1,&$/63(&,),&$7,2162) +9/9 ',675,%87,2175$16)250(56 TUNISIE TRANSFORMATEUR S.A :ULWWHQE\ M. BOUMALLA Adel Checked by : Mll. LAOUINI Radhia Approved by : M.LARIBI Mohamed Kamel %XVLQHVV'HSDUWPHQW,PP(O+DELE%XUHDX1ƒ%ORF%/HV%HUJHVGXODF$RXLQD

More information

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution High-Voltage Circuit-Breakers AP/ 7.5 kv up to 550 kv Power Transmission and Distribution The AP/ High-Voltage Circuit-Breakers Now Applicable for 550 kv Decades of our experience in high-voltage switching

More information

Gas Insulated Metal-clad Switchgear, HMGS!

Gas Insulated Metal-clad Switchgear, HMGS! Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,

More information

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

More information

Epoxy Technology Embedded Poles

Epoxy Technology Embedded Poles Embedded Poles ABB Power Technologies / 1-6994 E 14-03-03 - Epoxy processing Experience in manufacturing of epoxy resin for indoor and outdoor applications Processing of more than 1,000 tons epoxy resin

More information

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB

Micafil transformer oil-sf 6 bushings GARIP / RTKG kv. Power and productivity for a better world TM ABB Micafil transformer oil-sf 6 bushings GARIP / RTKG 72.5 55 kv Power and productivity for a better world TM ABB Design and accessories The design of the main RIP insulating body includes a solid, non-removable

More information

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 9 Transformer bushings, type GOB Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility

More information

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders Ergon Energy Corporation Limited Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders ETS12-01-01 Specification ETS12-01-01 Ver 3 Contents 1. Purpose and Scope... 1 2. References...

More information

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#: Single phase pole mounted Distribution Transformers 11kV Prepared by: ARY SAIDAHMED SHEKSAEED Electrical Engineer KEU ID#: 4252 Email: ary.sayd@hotmail.com 1 S # Contents Page # 1 Introduction 3 2 Type

More information

INSTALLATION MANUAL. Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules

INSTALLATION MANUAL. Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules INSTALLATION MANUAL Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules ING TABLE OF CONTENTS 1. General information 2 1.1 Standards

More information

DISTRIBUTION TRANSFORMERS CATALOGUE

DISTRIBUTION TRANSFORMERS CATALOGUE DISTRIBUTION TRANSFORMERS CATALOGUE COMPANY INFORMATION ARTRANS S.A. started off as a small factory in April 2, 1982 located in Mendoza, Argentina. Now, three decades later it is a globally recognized

More information

Smart FS medium frequency induction crucible furnace: Small capacity furnace solutions from ABB

Smart FS medium frequency induction crucible furnace: Small capacity furnace solutions from ABB Smart FS medium frequency induction crucible furnace: Small capacity furnace solutions from ABB ABB is committed to being your foundry partner ABB induction furnaces and inductive heating solutions bring

More information

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy. Energy Transmission & Distribution Services - Italy SVEPPI laboratory...our services for your success. Answers for energy. ...our services for your success ENERGY - T&D Services Experience teaches us that

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Technical Specification For Outdoor Substation Harmonic Filter Banks

Technical Specification For Outdoor Substation Harmonic Filter Banks Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field

More information

High Reliable Components for Power Factor Correction and Power Quality

High Reliable Components for Power Factor Correction and Power Quality High Reliable Components for Power Factor Correction and Power Quality It's all about saving your money! Contents Power Factor Correction Capacitors Page 3 Basic Harmonic Filter Reactors Page 11 Standard

More information

Non-Ventilated Automation Transformers 6

Non-Ventilated Automation Transformers 6 Non-Ventilated Automation Transformers 6 Automation Transformers - Non-Ventilated 50 VA to 45 SolaHD encapsulated transformers are rated for Hazardous Locations (Class 1, Division 2, Group A-D) as well

More information

Key features. DESIGNS: - Conservator type - Hermetically sealed

Key features. DESIGNS: - Conservator type - Hermetically sealed Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the

More information

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03 INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR469000 OR25 REV03 I II CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment

More information

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear. Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear www.siemens.com/energy Technology s Contents Application Page Benefits 2 Typical uses 2 and 3 Technical

More information

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions ABB a global leader ABB is a global leader in power and automation technologies that

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information