PHILADELPHIA FIRE DEPARTMENT WATER SUPPLY PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 100 PAGE 1

Size: px
Start display at page:

Download "PHILADELPHIA FIRE DEPARTMENT WATER SUPPLY PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 100 PAGE 1"

Transcription

1 PHILADELPHIA FIRE DEPARTMENT WATER SUPPLY PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 100 PAGE 1 SUPPLEMENT WATER SUPPLY Two separate water systems, the domestic and the high pressure, supply water for fire fighting for the City of Philadelphia. The domestic water supply system supplies treated water to the communities for consumption as well as supplying domestic low pressure fire hydrants for fire fighting. The high pressure system can supply either treated or untreated water under high pressure to a specific area of the city and is covered in greater detail in the high pressure supplement. Both water supply systems can be described as combination systems because they derive their working pressure from both direct pumping and gravity feed. WATER DISTRIBUTION SYSTEM Water distribution is accomplished through a series of interconnected pipes known as grids. Grids are composed of primary feeders (Transmission Mains - 16" or greater), secondary feeders (12" pipe) and distributors (8" pipe). PHILADELPHIA FIRE HYDRANTS LOW PRESSURE HYDRANT - LPH This type of hydrant (Fig.100-1) is orange and fitted with a single stem that operates a compression type valve. Water for this type of hydrant is supplied from the domestic water mains. Due to the climatic conditions in the Philadelphia area, all hydrants are of the Dry Barrel variety. When the hydrant valve is in the off or closed position, there is no water in the barrel above the frost line. The operating stem on a low pressure hydrant may be turned a maximum of 16 full turns or 32 half - turns, starting from a closed position. It is the policy of the Philadelphia Figure Low Pressure Hydrant Fire Department that a member operating a low pressure hydrant will not exceed 12 full turns or 24 half-turns. The reason for this policy is that the hydrant stem is made of brass. This metal has the ability to hold up well in wet environments; however, the alloy is relatively soft and can be easily damaged. The threads on the stem can be damaged by a member who inadvertently tries to exceed the designed travel of the valve, rendering the hydrant inoperative. Adhering to this policy will provide a safety margin of 4 full turns or 8 half-turns. To OPEN this type of hydrant, pull the wrench with the left hand, rotating the stem counterclockwise. See Figure Operating a LPH. DO NOT EXCEED 24 HALF - TURNS. REV. 6/27/

2 SUPPLEMENT 100 PAGE 2 PFD TRAINING MANUAL SUPPLEMENT _ of fire hydrants. Their illustration and operation is covered in the next section, under locking devices. Figure Operating a LPH There are a variety of types of low pressure hydrants used in the Philadelphia system. They vary in the number of outlets, the size of the outlets and in the type of operating stems used. The most common are those depicted in Figure and Figure In Figure 100-1, the Hydrant has only one 4 outlet. In Figure 100-3, the hydrant has a 4 outlet and a 2½ outlet. In Figure 100-4, the hydrant has two 4 outlets and is sometimes referred to as a Super-Hydrant. This type of hydrant is usually only found on transmission mains in areas of high fire loading, e.g. textile mill districts. Figure LPH, 4" & 2½" Outlets Variations in operating stem configurations were created in order to deter the illegal use LOCKING DEVICES There are several different locking devices used on hydrants in the Philadelphia area. Some involve different stem configurations, while another uses a special discharge cap. CENTER COMPRESSION LOCK (CCL) In Figure 100-5, the top of a Compression Lock hydrant is shown. Note the hole in the left side of the Bonnet. There is also another hole on the opposite side of Figure "Super Hydrant" 2-4" Outlets Figure Compression Lock Hydrant the bonnet. These holes are used to attach the compression lock adapter to the hydrant. In Figure 100-6, a Center Compression Lock Hydrant Adapter is shown. IMPORTANT NOTE: In some areas, compression style bonnets (cast iron top segments) have been installed on hydrants without compression stems. If the compression adapter is placed on this type of hydrant, damage can be done to the regular stem. If enough pressure is placed on the adapter, _RFH.DOC REV. 6/27/00

3 PFD TRAINING MANUAL SUPPLEMENT SUPPLEMENT 100 PAGE 3 Figure Center Compression Lock Hydrant Adapter the side locking pins will shear off, rendering the adapter unusable. To correctly identify a Center Compression Lock (CCL) hydrant, look for more than just the holes in the side of the bonnet. The operating stem of a compression hydrant is circular when viewed from the top (Fig 100-7). The stem of a standard low Figure Compression Stem pressure hydrant is almost triangular in shape, as seen in Figure Another problem that has been identified with center compression locking hydrants is the vertical movement or free-play of the center stem which may allow the stem to be Figure LPH - Regular Stem - Compression Bonnet raised and cocked at an angle. If the stem is on an angle when it is operated, it will jam and the hydrant will not open. Exerting pressure when this happens will break the lugs on the adapter. The center stem must be in a vertical position to operate properly. REV. 6/27/

4 SUPPLEMENT 100 PAGE 4 PFD TRAINING MANUAL SUPPLEMENT _ NOTE: COMPANIES USING A CCL HYDRANT SHOULD INSPECT THE CENTER STEM. BEFORE USING THE HYDRANT, IT MUST BE PROPERLY SEATED AND NOT ON AN ANGLE. ALCO SAFETY LOCK Another type of stem control device used to deter the unauthorized use of hydrants incorporates a specially shaped stem that requires the two piece wrench shown in Figure This wrench is known as the Alco Safety Lock Hydrant Wrench. This type of wrench F is used only on low igure Alco Safety Lock Hydrant pressure hydrants (LPH) fitted with the Alco Safety Lock adapter, Figure The contact surface of the stem is recessed and enclosed within a free turning protective cap. The only access is through a small slit just below the top of the cap. The wrench is opened, placed Figure Alco Safety Lock Hydrant Wrench around and inserted into the slot, then closed and locked into position with the use of the removable pin. Once the wrench is in place the hydrant can be operated in the same manner as any other LPH. Note: The P.W.D is currently removing this type of locking device. HYDRO SHIELD WRENCH/CAP In addition to systems restricting access to the operating stems of low pressure hydrants, there is another method which restricts access to the outlet. This system employs a special hydrant cap and wrench. Figure Hydro Shield Wrench The wrench shown in Figure is known as the Hydro Shield Wrench and can be used on all hydrants except the Alco Safety Lock hydrant. The Hydro Shield Wrench is used in conjunction with a Hydro Shield Cap, pictured in Figure Figure Hydro Shield Cap LPH OUT-OF-SERVICE (OOS) A low pressure hydrant that is placed Out-of-Service (OOS) by the Water Department will have a black plastic cap placed on the 4" outlet. Any Fire Department Unit encountering a low pressure hydrant that will not function properly for firefighting purposes will place a black plastic cap on the 4" outlet as soon as practicable and report the location of this low pressure hydrant to the Water Department Hydrant Desk. All engine companies have been issued black plastic caps for this purpose _RFH.DOC REV. 6/27/00

5 PFD TRAINING MANUAL SUPPLEMENT SUPPLEMENT 100 PAGE 5 FIRE HYDRANT COLOR CODING PHILADELPHIA SYSTEM Bonnets of domestic water system, low pressure fire hydrants, are painted in the following colors, which indicate the size of the water main supplying them: RED-16" or larger (Transmission Mains) GREEN- 10" or larger but less than 16 ORANGE - 8" or smaller For instructions on Inspection Procedures of Philadelphia Domestic Low Pressure Fire Hydrants refer to Operational Procedure #15. WATER MAPS There are two types of water maps used in the Philadelphia Fire Department. The The fire box is located in the center of the map, which shows an area two blocks in all directions from the center box location. Shown on the maps are streets, hydrant locations, box locations and the water mains. The size of the mains feeding those hydrants is also shown. MAP SYMBOLS The following symbols will be used in preparing the maps: Figure LPH <8" Domestic Low Pressure Hydrant (Fig ). (Mains feeding these hydrants are 8" or less in diameter and the bonnet is painted orange.) Figure LPH = 10" < 16 Domestic Low Pressure Hydrant (Fig ). (Mains feeding these hydrants are 10" or larger, but less than 16 in diameter and the bonnet is painted green.) Figure Water map (Company Level) first is carried on the field communications units - Field Com #1 and # 2. There is a map for each area of the city. The maps are used by the Logistics unit at all extra alarm fires in order to determine the best sources of water in an area. The second type of water map used (Fig ) is prepared at the company level and carried on the apparatus. A map is prepared for each fire box location in an engine company s local district. Figure LPH = 16" or > Figure High Pressure Hydrant Domestic Low Pressure Hydrant (Fig ). (Mains feeding these hydrants are 16" or larger in diameter and the bonnet is painted red.) High Pressure fire hydrant (Fig ). (The entire hydrant is painted red.) REV. 6/27/

6 SUPPLEMENT 100 PAGE 6 PFD TRAINING MANUAL SUPPLEMENT _ Figure Fire Alarm Box Fire Alarm Box, Figure Place the number of the box next to the symbol. An example of a company level water map is shown in Figure For more information on preparation and distribution consult the Forms Directive. A physical check will be made of local districts to verify the location of all hydrants and sizes of mains. Coordination of this program will be the responsibility of Platoon "A" Battalion Chiefs. Never leave any hydrant wrench on an unattended hydrant _RFH.DOC REV. 6/27/00

Chapter Quiz. Directions: Write the correct letter on the blank before each question.

Chapter Quiz. Directions: Write the correct letter on the blank before each question. Chapter 12 Quiz Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe dry-barrel and wet-barrel hydrants. 1. Most fire hydrants are made of: (605) A.

More information

MUELLER Hydrant Security Device

MUELLER Hydrant Security Device MUELLER HYDRANT DEFENDER SECURITY DEVICE 9A. Rev. 8-04 When conducting a vulnerability assessment (V.A.), infiltration of a municipal water supply through an unsecured fire hydrant should be a primary

More information

FIRE HYDRANT SPECIFICATION CHANGE SUBMITTAL

FIRE HYDRANT SPECIFICATION CHANGE SUBMITTAL FIRE HYDRANT SPECIFICATION CHANGE SUBMITTAL PACKAGE CONTENT 1. Reason for Change 2. Features and Benefits Provided 3. Specification Text 4. Specification Diagram JUSTIFICATION FOR FIRE HYDRANT SPECIFICATION

More information

Sentinel 250 Fire Hydrant

Sentinel 250 Fire Hydrant Maintenance Instructions manual table of contents PAGE Sentinel 250 Fire Hydrant Inspection and Lubrication 2 Rotating Hydrant to Face Desired Direction 3 Installing Extension Section 3-6 Restoring Service

More information

GENERAL FEATURES / SPEC M&H AWWA C502 FIRE HYDRANTS Style 929 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approval Type: Compression type, opening against line pressure.

More information

VMA Presentation Pressure Seal (MSS-SP-144) and ASME B Update Carlos E. Davila, PE March 2014

VMA Presentation Pressure Seal (MSS-SP-144) and ASME B Update Carlos E. Davila, PE March 2014 VMA Presentation Pressure Seal (MSS-SP-144) and ASME B16-2013 Update Carlos E. Davila, PE March 2014 CRANE FLUID HANDLING Fugitive Emissions Update EPA has been reducing the allowable fugitive emissions

More information

GBV-G Balancing Valves

GBV-G Balancing Valves Ductile Iron ASTM A6, Grade 6-4-2 The Series GBV is a multi-turn, Y-style globe valve designed for accurate determination and control of fluid flow to circuits requiring precise balancing. Max. Working

More information

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler System Controls Revised

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 5 Sprinkler System Controls Revised Engine Module Page 1 of 5 SPRINKLER SYSTEM CONTROLS Control and Operating Valves Integral to each sprinkler system is the main control valve. These valves are used to shut off the supply of water when

More information

AVK SAUDI VALVES MANUFACTURING COMPANY

AVK SAUDI VALVES MANUFACTURING COMPANY AVK SAUDI VALVES MANUFACTURING COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION

More information

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL Item No.s/Description Item No. Description Material Specification HYDRANT Qty. Req d Item No. Description Material Specification 1 Operating

More information

K81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

K81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS GUARDIAN K81-D FIRE HYDRANT CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C502 NSF 61 140 YEARS WWW.KENNEDYVALVE.COM C For Generations COMPONENTS AND FEATURES A B C E D F G H J L M K N P Q S R

More information

Data Sheet Issue A

Data Sheet Issue A General Description The Rapidrop Fig 601/602 dry barrel post / flushing fire hydrant is designed to be a trouble free, easy to maintain hydrant. The Fig 601/602 fire hydrant is rated for a working pressure

More information

PRODUCT MANUAL TRENCH ADAPTER

PRODUCT MANUAL TRENCH ADAPTER PRODUCT MANUAL TRENCH ADAPTER INDEX TRENCH ADAPTER PAGE INTRODUCTION... 8-2 FEATURES AND BENEFITS... 8-3 SPECIFICATIONS... 8-3 ORDERING Dimensions: Overall Dimensions and Weights... 8-4 Trench Depth and

More information

MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW)

MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW) MICROPROCESSOR CONTROL WATER SUPPLY SYSTEM (MPR-01AW) Installation, Operation, and Maintenance Manual REV. "B" REV. "C" PLEASE READ ENTIRE DOCUMENT BEFORE PROCEEDING WITH INSTALLATION Energy Saver has

More information

EXTENDA-BAN VALVE REPAIR AND MAINTENANCE

EXTENDA-BAN VALVE REPAIR AND MAINTENANCE 7 EXTENDA-BAN VALVE REPAIR AND MAINTENANCE 1 1. Detach the Valve and Extension from the hose. Carefully remove the mesh strainer. Squeeze the Trigger to drain all liquid from the Valve. 2 3 4 5 6 2. Remove

More information

Guide for Primary Injection Testing WL Circuit Breakers. Document No. : 11-C

Guide for Primary Injection Testing WL Circuit Breakers. Document No. : 11-C s Guide for Primary Injection Testing WL Circuit Breakers Document No. : 11-C-9036-00 Before Beginning... Qualified Person Siemens type WL circuit breakers should only be only be operated, inspected, and

More information

September 2012 / M&H C502 / Model 129

September 2012 / M&H C502 / Model 129 GENERAL FEATURES / GENERAL SPEC M&H AWWA C502 FIRE HYDRANTS Model 129 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approved Type: Compression type, opening against line

More information

Tyger Drafting Eductors

Tyger Drafting Eductors - Tyger Drafting Eductors Pump it dry DRAFT USING SOFT HOSE! VITA MOTIVATOR P.O. Box 8139 Englewood, NJ 07631 201-567-1151 : fax 201-734-8482 michaels.greene@att.net t Tyger Drafting Tyger Eductor Drafting

More information

K81 Guardian Fire Hydrants. Operation & Maintenance Guide

K81 Guardian Fire Hydrants. Operation & Maintenance Guide Kennedy Valve K81 Guardian Fire Hydrants Operation & Maintenance Guide Installation 1. When hydrants are received from manufacturer they should be handled carefully to avoid breakage and damage to flanges.

More information

Typical Feed Water Heater Isolation System.

Typical Feed Water Heater Isolation System. Type AVS 4/5 Typical Feed Water Heater Isolation System. Features and Benefits These valves are designed to bypass high pressure feedwater around a group of heaters in the event of high water level in

More information

2-port seat valves PN25 with flanged connection

2-port seat valves PN25 with flanged connection 4 373 Acvatix 2-port seat valves PN25 with flanged connection VVF52.. Nodular cast iron EN-GJS-400-8-LT valve body DN 5...40 k vs 0.6...25 m 3 /h Can be equipped with SAX..-electromotoric or SKD..- or

More information

Wear Protection ESCO Kwik-Lok Application Guide for Crushing and Conveying P6001UWS01L0312

Wear Protection ESCO Kwik-Lok Application Guide for Crushing and Conveying P6001UWS01L0312 ESCO Kwik-Lok Wear Protection Application Guide for Crushing and Conveying P6001UWS01L0312 Safety www.escocorp.com General Safety Information The safety practices described in this manual are meant as

More information

EST Group DC /97 REV 15 12/17 Page 1 of 6

EST Group DC /97 REV 15 12/17 Page 1 of 6 EST Group DC1220 02/97 REV 15 12/17 Page 1 of 6 Procedure for Pop-A-Plug CPI/Perma Near End Installation Curtiss Wright Proprietary This document is the property of and contains information proprietary

More information

BALL VALVES. Industry-Leading 300psi Low Lead Ball Valves

BALL VALVES. Industry-Leading 300psi Low Lead Ball Valves BALL VALVES Industry-Leading 300psi Low Lead Ball Valves Designed and Manufactured to Meet Your Needs 1 Lockwing Accepts bullet lock (when equipped on meter valve). 2 Stainless steel reinforced seat gaskets

More information

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised

ESCONDIDO FIRE DEPARTMENT TRAINING MANUAL ENGINE MODULE HOSE PAGE 1 OF 20 Supply Hose Lays Revised HOSE 12-01-16 PAGE 1 OF 20 There are five base North Zone supply hose lays: Forward Lay Spotting a Hydrant Stationary Lay Reverse Lay Split Lay Escondido Fire Department Core Hose Lays The Escondido Fire

More information

Temperature Sensor Series

Temperature Sensor Series GENERAL DESCRIPTION The patented* No. 85026-Series Temperature Sensor contains a two-position valve operated by temperature variations around the integral sensing bulb. It is used to vent or block a pneumatic

More information

U STYLE "TP" TIME RELEASE UNION SWITCH & SIGNAL DIVISION OF WESTINGHOUSE AIR BRAKE CO. INSTALLATION AND MAINTENANCE AUGUST, 1951

U STYLE TP TIME RELEASE UNION SWITCH & SIGNAL DIVISION OF WESTINGHOUSE AIR BRAKE CO. INSTALLATION AND MAINTENANCE AUGUST, 1951 INSTALLATION AND MAINTENANCE j... STYLE "TP" TIME RELEASE '" INSTRUCTION PAMPHLET U--5029 AUGUST, 1951 UNION SWITCH & SIGNAL DIVISION OF WESTINGHOUSE AIR BRAKE CO. SWISSVALE, PA. 2M-B-51-2 PRINTED IN U.

More information

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA Page 1 of 5 1. DESCRIPTION Viking Frame Style Spray Nozzles are small, directional spray nozzles for use on water spray systems. They are thermosensitive glass bulb style nozzles, however they may be ordered

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE April 13, 2007 Spray Nozzle 31a 1. DESCRIPTION Viking Frame Style Spray Nozzles are small, directional spray nozzles for use on water spray systems. They are thermosensitive glass bulb style nozzles, however

More information

DSL & SVK Lubricators. Manzel DSL LUBRICATOR SVK PUMP W/LIQUID FILLED SIGHT FEED SIGHT GLASS

DSL & SVK Lubricators. Manzel DSL LUBRICATOR SVK PUMP W/LIQUID FILLED SIGHT FEED SIGHT GLASS Manzel DSL & SVK Lubricators SVK LUBRICATOR SVK PUMP W/LIQUID FILLED SIGHT FEED DSL PUMP W/ DRY-VAC SIGHT GLASS DSL LUBRICATOR DSL & SVK BOX LUBRICATOR Wide choice of standard modular components helps

More information

Figs. 800 Verticle, 800 W. Fig. 800 Vertical Type Fig. 800 W. Wall type.

Figs. 800 Verticle, 800 W. Fig. 800 Vertical Type Fig. 800 W. Wall type. Indicator Posts Indicator posts are controls, extending aboveground, for operating underground sprinkler system valves. As an important feature of their design, a target or indicator, visible through an

More information

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY

mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY mh-valve.com 129 HYDRANT AWWA C502 NSF 61/372 CERTIFIED UL LISTED FM APPROVED 250 PSI WORKING PRESSURE 10-YEAR LIMITED WARRANTY 129 HYDRANT YESTERDAY, TODAY, & TOMORROW For more than 85 years, the M&H

More information

Repair Manual MECHANICAL OIL VALVE

Repair Manual MECHANICAL OIL VALVE MECHANICAL OIL VALVE Repair Manual This Manual for Mechanical Oil Valves purchased before December 2017 INDEX Introduction... 1 Elastomer Materials... 2 Repair Kit Contents... 3 Disassembly... 4 Appendix

More information

Pressure Relief Valve Maintenance Manual

Pressure Relief Valve Maintenance Manual Technical Manual 1098T Pressure Relief Valve Maintenance Manual Farris Engineering Division of Curtiss-Wright Flow Control Corporation TABLE OF CONTENTS - Manual Revision 0 Introduction & Safety Tips...

More information

K81-DD FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

K81-DD FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS GUARDIAN K81-DD FIRE HYDRANT CERTIFICATIONS ISO 9001 ISO 14001 BS OHSAS 18001 AWWA C502 NSF 61 140 YEARS WWW.KENNEDYVALVE.COM C For Generations COMPONENTS AND FEATURES A B C E D F G H J K M L N P Q S R

More information

MAX-FIRE AND E-FIRE ELECTRONIC DISTRIBUTORS

MAX-FIRE AND E-FIRE ELECTRONIC DISTRIBUTORS INSTALLATION INSTRUCTIONS MAX-FIRE AND E-FIRE ELECTRONIC DISTRIBUTORS NOTE: This product is applicable to pre-1966 California and pre-1968 federally certified passenger cars. It is also applicable to non-emission

More information

MANUAL VALVE ACTUATORS. Engineering Creative Solutions for Fluid Systems Since 1901

MANUAL VALVE ACTUATORS. Engineering Creative Solutions for Fluid Systems Since 1901 MANUAL VALVE ACTUATORS Engineering Creative Solutions for Fluid Systems Since 1901 TABLE OF CONTENTS MANUAL VALVE ACTUATOR Scope of Line: Valve Actuators... 1 Manual Valve Actuator Dimensional Data...

More information

WEAPONX CIRCUIT COMPRESSION

WEAPONX CIRCUIT COMPRESSION WeaponX Ignition Coil Technology WeaponX designs and employs the greatest performance proven technologies available. The creation of a high quality ignition system has been a challenging process for OEMS

More information

WINCH OPERATING PRACTICES 1. Read the manufacturer's instructions before operating the winch. 2. Always inspect, test maintain and operate this winch in accordance with American National Standards Institute

More information

DA Series Diaphragm Valve

DA Series Diaphragm Valve DA Series Diaphragm Valve Service Instructions Pneumatically Actuated Valve Toggle Valve Valve Valve Valves are shown with tube butt weld ends. These instructions also apply to DA series valves with any

More information

DUCTILE IRON FLANGED GATE VALVES for gas distribution DN40 DN300 PN16 max operating pressure MOP 16 bar

DUCTILE IRON FLANGED GATE VALVES for gas distribution DN40 DN300 PN16 max operating pressure MOP 16 bar DUCTILE IRON FLANGED GATE VALVES for gas distribution DN40 DN00 PN6 max operating pressure MOP 6 bar Opracował T.Włoch 7..206 Sprawdził M. Dyrlaga 7..206 Zatwierdził J.Karpiński 7..206 Ductile Iron Flanged

More information

Specifications For Valve Insertion System

Specifications For Valve Insertion System Specifications For Valve Insertion System Equipment For Valve Insertion Pipe Sizes: 4 (100mm) Through 12 (300mm) 1.0 SCOPE This specification covers the furnishing, complete EZ Valve insertion system.

More information

Rev. 2/16 MUELLER Fire Hydrant Reference Manual Mueller Co. Printed in the U.S.A.

Rev. 2/16 MUELLER Fire Hydrant Reference Manual Mueller Co. Printed in the U.S.A. Rev. 2/16 MUELLER Fire Hydrant Reference Manual 2016 Mueller Co. Printed in the U.S.A. Index 1 Fire Hydrant Reference Material Index Index...1 Identification...2-36 Dry Barrel Hydrants - AWWA...3-21 Dry

More information

PET UNIT DOSE TABLE INSTALLATION MANUAL FN: Rev A 1/18

PET UNIT DOSE TABLE INSTALLATION MANUAL FN: Rev A 1/18 PET UNIT DOSE TABLE INSTALLATION MANUAL 042-448 FN: 09-243 Rev A 1/18 Pet Unit Dose Table This manual covers installation procedures for the following products: 042-448 Table, PET, Unit Dose 2 Biodex Medical

More information

OPTIMAL VALVE SOLUTIONS FOR OIL AND GAS PLANTS

OPTIMAL VALVE SOLUTIONS FOR OIL AND GAS PLANTS AVK FLOW CONTROL OPTIMAL VALVE SOLUTIONS FOR OIL AND GAS PLANTS InterApp World Valve Wouter Witzel TEC artec AVK 1 2 AVK FLOW CONTROL l OIL & GAS PLANTS CONTENT: AVK FLOW CONTROL 4-5 OFFSHORE PRODUCTION

More information

AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING

More information

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation Deluge Valve DV-5 Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation GeneralDescription The Model DV-5 Deluge Valve (described in Technical

More information

SECTION VALVES AND OPERATORS

SECTION VALVES AND OPERATORS SECTION 15200 VALVES AND OPERATORS PART 1 - GENERAL 1.1 SUBMITTALS A. Shop Drawings: 1. Product data sheets for make and model. 2. Complete catalog information, descriptive literature, specifications,

More information

SERIES OPERATION AND MAINTENANCE MANUAL

SERIES OPERATION AND MAINTENANCE MANUAL SERIES OPERATION AND MAINTENANCE MANUAL This manual CONTAINS IMPORTANT WARNINGS, S and OTHER INSTRUCTIONS. Read and understand the instruction manual Carefully, before use and retain it for reference.

More information

The Knowledge Bank at The Ohio State University. Ohio State Engineer. Electrolysis in Underground Structures

The Knowledge Bank at The Ohio State University. Ohio State Engineer. Electrolysis in Underground Structures The Knowledge Bank at The Ohio State University Ohio State Engineer Title: Creators: Issue Date: Publisher: Electrolysis in Underground Structures Rei, P. F. Pepper, H. C. Hoover, C. H. Frankenberg, R.

More information

LINDGREN-PITMAN General Maintenance of Lindgren-Pitman Hydraulic Systems & Equipment

LINDGREN-PITMAN General Maintenance of Lindgren-Pitman Hydraulic Systems & Equipment LINDGREN-PITMAN General Maintenance of Lindgren-Pitman Hydraulic Systems & Equipment Page 1 Lindgren Pitman hydraulic driven equipment is designed to give long reliable service with a minimum of repairs

More information

Z3 Air (80) GENERAL. BAM: Bomber Aerospace Material. Special alloy developed from aerospace material. Ø TRAVEL 80 L.MAX=461 L.L.=451 L.

Z3 Air (80) GENERAL. BAM: Bomber Aerospace Material. Special alloy developed from aerospace material. Ø TRAVEL 80 L.MAX=461 L.L.=451 L. (80) 175 18 80 Ø30 +0.05 0 55 L.MAX=461 L.L.=451 L.MIN=371 396 ±0,1 TRAVEL 80 ±2 Ø30 15 20 0-0.1 +1 0 248 GENERAL Special air/oil damped cross-country fork: each leg uses pressurized air blown through

More information

LINDGREN-PITMAN General Maintenance of Lindgren-Pitman Hydraulic Systems & Equipment

LINDGREN-PITMAN General Maintenance of Lindgren-Pitman Hydraulic Systems & Equipment LINDGREN-PITMAN General Maintenance of Lindgren-Pitman Hydraulic Systems & Equipment Page 1 Lindgren-Pitman hydraulic driven equipment is designed to give long reliable service with a minimum of repairs

More information

Big Flow Systems. Major innovations in fire fighting and water transfer technology

Big Flow Systems. Major innovations in fire fighting and water transfer technology Big Flow Systems Major innovations in fire fighting and water transfer technology An integrated mobile high capacity foam and water delivery solution. Use as a comprehensive system or as individual components

More information

2.3.2 Hydrant Maintenance

2.3.2 Hydrant Maintenance 2.3.2 Hydrant Maintenance YOUR ORGANIZATION STANDARD OPERATING PROCEDURES/GUIDELINES TITLE: Hydrant Maintenance NUMBER: 2.3.2 PREPARED BY: SECTION/TOPIC: Special Programs ISSUE DATE: REVISED DATE: APPROVED

More information

MUELLER. Super Centurion 350 Fire Hydrant. Reliable Connections. Inspection and Maintenance 2. Filling Oil Reservoir 3. Facing the Hydrant 4

MUELLER. Super Centurion 350 Fire Hydrant. Reliable Connections. Inspection and Maintenance 2. Filling Oil Reservoir 3. Facing the Hydrant 4 operating Instructions manual MUELLER Super Centurion 350 Fire Hydrant table of contents PAGE Inspection and Maintenance 2 Filling Oil Reservoir 3 Facing the Hydrant 4 Restoring Service after Traffic Knockover

More information

2-Port Seat Valves with Flange, PN 25

2-Port Seat Valves with Flange, PN 25 4 7 2-Port Seat Valves with Flange, PN 25 VVF52... Nodular cast iron EN-GJS-400-8-LT valve body DN 5...40 k vs 0.6...25 m /h Can be equipped with SQX- electromotoric or SKD...- or SKB...- electrohydraulic

More information

Number: ES-57 Revision: F

Number: ES-57 Revision: F USE OF THIS DOCUMENT The master copy of this document resides in electronic format. Printed copies of this document are for convenience only. Verify that the revision of this printed document matches the

More information

Hydrant Security. Taking that first step. A White Paper Published by. Chattanooga, TN 37450

Hydrant Security. Taking that first step. A White Paper Published by. Chattanooga, TN 37450 Hydrant Security Taking that first step A White Paper Published by Chattanooga, TN 37450 Form 12714 Rev. 7/11 Copyright - Mueller Co., Chattanooga, TN - April 2011 Hydrant Security Taking that First Step

More information

I-BFV.KIT Butterfly Valve Gear Operator Replacement

I-BFV.KIT Butterfly Valve Gear Operator Replacement SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before

More information

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G Content : 4.1 Hydraulic and Pneumatic actuators. 10 Marks Hydraulic Actuators - Hydraulic cylinders (single, double acting and telescopic) construction and working, Hydraulic motors (gear and piston type)

More information

FIRE HYDRANTS. Wet Barrel Fire Hydrants

FIRE HYDRANTS. Wet Barrel Fire Hydrants FIRE HYDRANTS Wet Barrel Fire Hydrants Jones Wet Barrel Fire Hydrants With over 100 years of experience on the west coast the heart of the wet barrel market James Jones Company is the innovator in the

More information

INSTALLATION INSTRUCTIONS. Put this information in the glove box with the vehicle owner's manual. INSTALLATION PARTS LIST

INSTALLATION INSTRUCTIONS. Put this information in the glove box with the vehicle owner's manual. INSTALLATION PARTS LIST INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII 40377 ATTACHMENT 2009 CR-V P/N 08L03-SCV-100 Issue Date AUG 2008 Put this information in the glove box with the vehicle owner's manual.

More information

SwayPro. NOTE: A minimum tongue weight of 200 lbs. is required THANK YOU

SwayPro. NOTE: A minimum tongue weight of 200 lbs. is required THANK YOU SwayPro Owner s Manual & Installation Instructions Serial Number Standard Hitch Head w/ Clamp-On Rotating Latches BXW0350 350 lbs. maximum tongue weight capacity BXW0550 550 lbs. maximum tongue weight

More information

Diffusers. Comfort for Any Business Situation

Diffusers. Comfort for Any Business Situation Diffusers Comfort for Any Business Situation The Right Diffuser Is the One You Never Notice knows that you have more than one goal in mind when you select air diffusers for your office building. Blending

More information

Operating Manual. Hydra S (W)VAC

Operating Manual. Hydra S (W)VAC Operating Manual Pop up Sprinkler Hydra S (W)VAC PERROT TDP053e.doc Rev. 16.06.2015 Page 1 / 21 Contents 1 SAFETY... 3 1.1 HOW INSTRUCTIONS ARE MARKED IN THIS MANUAL... 3 1.2 HAZARDS OF IGNORING SAFETY

More information

102 Differential Pressure Switch

102 Differential Pressure Switch Knurled cap over set point adjustment High side process connection 1/4 NPT(F) [1/2 NPT(F) optional] onal] Hermetically sealed switching element capsule with 18 AWG wire leads, 18 (45.7 cm) in length 102

More information

Installation and Operation Instructions

Installation and Operation Instructions Peerless Pump Company PJPC Jockey Pump Controllers Installation and Operation Instructions Peerless Pump Company 2005 Dr. M. L. King Jr. Street Indianapolis, IN 46202 Bulletin 4857341 Rev. December 21,

More information

CENTRIFEEDER ELECTRONICS

CENTRIFEEDER ELECTRONICS CENTRIFEEDER ELECTRONICS FOR USE WITH CENTRIFEEDER with Integrated Vibratory Control REV 08/13 ADDENDUM VERSION 6.22 SOFTWARE Copyright 2011 Eastern Instrument Laboratories, Inc. All Rights Reserved. TABLE

More information

INSTALLATION & USER S GUIDE

INSTALLATION & USER S GUIDE REKLUSE MOTOR SPORTS TorqDrive Manual Clutch Kit for Harley-Davidson Big Twin Motorcycles INSTALLATION & USER S GUIDE Doc ID: 191-2841A Doc Rev: 082417 OVERVIEW This kit is compatible ONLY with the OEM

More information

Instructions for Mounting and Operation of ARC Model TS Watt Tungsten-Halogen Light Source

Instructions for Mounting and Operation of ARC Model TS Watt Tungsten-Halogen Light Source 15 Discovery Way, Acton, MA 01720 Phone: (978)263-3584, Fax: (978)263-5086 Web Site: www.acton-research.com www.piacton.com Instructions for Mounting and Operation of ARC Model TS-428 250 Watt Tungsten-Halogen

More information

PROCEDURE TO BE FOLLOWED WHEN COMBUSTION PROBLEMS ARE EXPERIENCED WITH APPLIANCES HAVING VAPORISING BURNERS

PROCEDURE TO BE FOLLOWED WHEN COMBUSTION PROBLEMS ARE EXPERIENCED WITH APPLIANCES HAVING VAPORISING BURNERS OFG/102 PROCEDURE TO BE FOLLOWED WHEN COMBUSTION PROBLEMS ARE EXPERIENCED WITH APPLIANCES HAVING VAPORISING BURNERS Cover Price 10 (ex.vat and p&p) (Please note this information sheet is available from

More information

Suction Guide & Flo-Trex Valve Series

Suction Guide & Flo-Trex Valve Series Suction Guide & Flo-Trex Valve Series Pump Trim FILE NO: 6-1 DATE: August 2010 SUPERSEDES: 6-1 DATE: July 200 Series SG & FTV Suction Guides Designed for direct mounting on the suction flange of horizontal

More information

INSTRUCTIONS. SILEX demineralizers. Type 1 B and 2 B. Our World is Water. D1A-30Bver4. Instructions. SILHORKO-EUROWATER A/S Phone

INSTRUCTIONS. SILEX demineralizers. Type 1 B and 2 B. Our World is Water. D1A-30Bver4. Instructions. SILHORKO-EUROWATER A/S Phone Instructions D1A-30Bver4 INSTRUCTIONS SILEX demineralizers Type 1 B and 2 B SILHORKO-EUROWATER A/S Phone + 45 86 57 12 22 DK-8660 Skanderborg info@eurowater.com Denmark www.eurowater.com Our World is Water

More information

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE INDEX SERIES 2500 DUCTILE IRON RESILIENT WEDGE GATE VALVE OPERATION and MAINTENANCE MANUAL. OPERATION AND MAINTENANCE Operation,

More information

2006 MINI Cooper S GENINFO Starting - Overview - MINI

2006 MINI Cooper S GENINFO Starting - Overview - MINI MINI STARTING SYSTEM * PLEASE READ THIS FIRST * 2002-07 GENINFO Starting - Overview - MINI For information on starter removal and installation, see the following articles. For Cooper, see STARTER WITH

More information

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING AND

More information

AMERICAN AVK COMPANY AVK SERIES HIGH PRESSURE, MODERN, DRY BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

AMERICAN AVK COMPANY AVK SERIES HIGH PRESSURE, MODERN, DRY BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS AMERICAN AVK COMPANY AVK SERIES 2700 - HIGH PRESSURE, MODERN, DRY BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING

More information

MSI SINGLE IDLER BELT SCALE

MSI SINGLE IDLER BELT SCALE MSI SINGLE IDLER BELT SCALE Instruction Manual PL-319 January 2001 33453190 Rev. 1.2 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect

More information

TABLE OF CONTENTS. 3 Outlet Stainless Steel Body. 3 Outlet Ductile Body. 2 Outlet Ductile Body 2 Outlet Bronze Body

TABLE OF CONTENTS. 3 Outlet Stainless Steel Body. 3 Outlet Ductile Body. 2 Outlet Ductile Body 2 Outlet Bronze Body AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS EXPLODED ASSEMBLY / PARTS LIST INTRODUCTION / DESCRIPTION RECEIVING AND STORAGE INSTALLATION

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS FRONT DISC BRAKE CONVERSION KITS: A132-1, A133, A133-1 A134, A134-1 1968-73 MUSTANG/FORD Thank you for choosing STAINLESS STEEL BRAKES CORPORATION for your braking needs. Please

More information

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping. SECTION 23 05 23 GENERAL-DUTY VALVES FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section includes valves for building services piping. 1.2 REFERENCES A. AGA Z21.22 (American Gas Association) - Relief Valves

More information

TABLE OF CONTENTS PART 7 - MACHINERY AND MACHINERY GUARDING

TABLE OF CONTENTS PART 7 - MACHINERY AND MACHINERY GUARDING TABLE OF CONTENTS PART 7 - MACHINERY AND MACHINERY GUARDING Page DEFINITIONS...7-1 SAFEGUARDS...7-1 GUARDING...7-2 PULLEYS, BELTS AND BELT-SHIFTERS...7-3 CONTROLS...7-3 FLYWHEELS...7-3 GRINDING WHEELS...7-3

More information

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM.  QAD#IM6055.REVA LSSN Butterfly Valve Installation Operation Maintenance Licence Number: 5326 www.challengervalves.com.au 1 Index 1. INTRODUCTION 1.1 Design Features 3 1.2 Flange and Pipe Compatibility 4 1.3 Operating

More information

Valveworks USA Operation and Maintenance Booklet Model FC

Valveworks USA Operation and Maintenance Booklet Model FC Operation and Maintenance Booklet Model FC MODEL FC 3000, 5000, 10000, & 15000 W.P. FLOATING SLAB GATE VALVES 1 13/16-2 1/16-2 9/16-3 1/16-4 1/16 BOOKLET APPROVED BY: INTRODUCTION In appreciation to you

More information

INTEGRID TRACK (120V) SPECIFICATIONS

INTEGRID TRACK (120V) SPECIFICATIONS INTEGRID TRACK (120V) SPECIFICATIONS GENERAL Integrid Track shall be a combination Track and main runner for mech - anically supporting suspended ceiling systems. Integrid Track shall allow fixtures to

More information

HL: Mutual Induction. Mutual / Self-Induction Learning Outcomes. Mutual / Self-Induction Learning Outcomes

HL: Mutual Induction. Mutual / Self-Induction Learning Outcomes. Mutual / Self-Induction Learning Outcomes 1 Mutual / Self-Induction Learning Outcomes HL: Define and discuss mutual induction for two adjacent coils. HL: Demonstrate mutual induction. HL: Define and describe self-induction. HL: Demonstrate self-induction.

More information

SAFETY SAFETY CABLE INSTALLATION /00 1 of 6

SAFETY SAFETY CABLE INSTALLATION /00 1 of 6 SAFETY DO NOT INSTALL, OPERATE OR USE THIS EQUIPMENT UNTIL THE FOLLOWING OPERATING AND SAFETY INSTRUCTIONS HAVE BEEN READ AND UNDERSTOOD. This symbol is used to bring attention to safety precautions and

More information

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS SECTION 22 11 23.13 (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Packaged Domestic Water Booster Pumps B. Related Sections: 1.02 REFERENCES 1. Section

More information

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP PAGE 1 OF 10 OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP EFFICIENT, EASY OPERATION Air operated pump Wide range of pressures and volumes Easy to operate controls Output pressure

More information

Q5024A,B Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS

Q5024A,B Globe Valve Linkages FOR DIRECT COUPLED ACTUATORS Q5024A,B Globe Linkages FOR DIRECT COUPLED ACTUATORS PRODUCT DATA Heavy-duty steel rack pinion construction aluminum die-cast housing. Maintenance-free construction. Flexible actuator mounting orientation.

More information

The ECLIPSE #9800 & The ECLIPSE #9800WC

The ECLIPSE #9800 & The ECLIPSE #9800WC Operating and Maintenance Manual Installation of The ECLIPSE #9800 & The ECLIPSE #9800WC The John C. Kupferle Foundry Company 2511 North 9 th Street St. Louis, Missouri 63102, USA Tel: 1-800-231-3990 Tel:

More information

Series 706 Butterfly Valves (300 PSI/2065 kpa)

Series 706 Butterfly Valves (300 PSI/2065 kpa) IPS CARBON STEEL PIPE GROOVED VALVES Series 706 Butterfly Valves (300 PSI/2065 kpa) 08.17 VICTAULIC IS AN ISO 9001 CERTIFIED COMPANY PRODUCT DESCRIPTION The Series 706 grooved end butterfly valve offers

More information

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No: Three-Piece ball valve EA-307 Series PED Category I, II EA-307 User Manual English Version [DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary.

More information

Sentinel 250 Fire Hydrant. Solid design and features to meet any municipal requirement.

Sentinel 250 Fire Hydrant. Solid design and features to meet any municipal requirement. Sentinel 250 Fire Hydrant Solid design and features to meet any municipal requirement. Product Features That meet any municipal requirement. 1 Operating Nut Shields the hold down nut from tampering and

More information

Technical Manual MSI Hydraulic Adjustable Choke

Technical Manual MSI Hydraulic Adjustable Choke Technical Manual MSI Hydraulic Adjustable Choke MSI A Division of Dixie Iron Works, Ltd. 300 W. Main St. Alice, TX 78332 www.diwmsi.com (800) 242-0059 Revision A TABLE OF CONTENTS SECTION 1 WARNINGS...

More information

Tri-Spark Ignition System Installation Triple Cylinder TRI-0001

Tri-Spark Ignition System Installation Triple Cylinder TRI-0001 Tri-Spark Ignition System Installation Triple Cylinder TRI-0001 There are potentially lethal high voltages produced at the ignition coils and spark plugs, therefore every precaution must be taken to prevent

More information

Manual Tire Changing Systems OWNERS MANUAL

Manual Tire Changing Systems OWNERS MANUAL OWNERS MANUAL Manual Tire Changing Systems MODEL #T600 (38600) CENTER POST TIRE CHANGING SYSTEM BENCH MOUNT/RIM CLAMP ADAPTER For use on res size 4 to 12 MODEL #T601 (38601) CENTER POST TIRE CHANGING SYSTEM

More information

Orenco Automatic Distributing Valve Assemblies

Orenco Automatic Distributing Valve Assemblies This article may describe design criteria that was in effect at the time the article was written. FOR CURRENT DESIGN CRITERIA, call Orenco Systems, Inc. at 1-800-348-9843. Orenco Automatic Distributing

More information

HTX-HTH SEPARATORS I&O MANUAL

HTX-HTH SEPARATORS I&O MANUAL INSTALLATION OPERATIONS AND MAINTENANCE HTX-HTH SEPARATORS I&O MANUAL 1365 N. Clovis Avenue Fresno, California 93727 (559) 255-1601 www.lakos.com LS-714B (Rev. 11/17) TABLE OF CONTENTS Table of Contents...

More information