GAS CHROMATOGRAPHY LGC-A1 SERIES

Size: px
Start display at page:

Download "GAS CHROMATOGRAPHY LGC-A1 SERIES"

Transcription

1 GAS CHROMATOGRAPHY LGC-A1 SERIES

2 Gas Chromatography LGC-A1 Series Gas chromatography LGC-A10 Gas chromatography system LGC-A10 comes with different detectors and each detector individually controls the temperature of the system. This gas chromatography comes with packed column injectors, split/split less injectors, capillary and cool-on column. It is possible to achieve lower limit of detection using these unique injector system. It gives accurate, high precision control, reliable results. Features 7 steps temperature rising function LCD display to view test parameters Individual temperature controlling detectors Self-diagnosis, keyboard locking function Data storage during power off Different detectors with high stability and sensitivity for selection Stable and speedy program for furnace heating Unique injectors system for detection of lower limit Applications Used in the analysis of oil extraction and refining industry, petrochemical analysis, gas industry and in quality control of medicines, food and chemicals.

3 Chromatography column type Chromatography column length Chromatography column diameter Temperature operating range Maximum programmed heating speed Programmed temperature steps Temperature setting precision Programmed heating rate Furnace dimension Injectors Detectors FID TCD FPD Capillary and Packed column 100 to 500 mm 0.2 to 0.5 mm Higher than the room temperature of 5 0 C to C C/min 7 steps 1 0 C 0.1 to C/min (increment of C) mm LGC-A10 Packed column injectors, split/split less capillary column injectors, cool on-column injectors Following detectors can be selected as per the requirement Maximum temperature control: C LOD: g/s [n-c 16] Linear dynamic range: 10 7 Drift: A/30 min Noise: A Maximum temperature control: C LOD: mv.ml/mg [n-c 16] Linear dynamic range: 10 4 Drift: 10 µv/30 min Noise: 20 µa Maximum temperature control: C LOD: g/s (P), g/s (S Linear dynamic range: 10 3 (P), 10 2 (S) Drift: A/30min Noise: A

4 LGC-A10 ECD NPD PDHID Maximum temperature control: C LOD: g/ml (y-666) Linear dynamic range: 10 4 Drift: 5 µv/30min Noise: 20µA Maximum temperature control: C LOD: g/s (P), g/s (N) Linear dynamic range: 10 3 (P), 10 3 (N) Drift: A/30min Noise: A LOD: 5ppb

5 Gas Chromatography LGC-A1 Series Gas chromatography LGC-A11 Gas chromatography system LGC-A11 is equipped with superior quality, high-precision electronic flow/ pressure control system. This gas chromatograph system has accurate tracking design and accurate programmed heating control system for the furnace temperature. Incorporated with safe and reliable functions of self-ignition and hydrogen leakage self-protection. Features EPC controlled injector flow, column carrier flow and detector gas flow 7 steps temperature rising function LCD display to view test parameters Different detectors with high stability and sensitivity for selection Quick heating and cooling system Gas circuit technology with blowback function Adopted with imported valve configuration system Use of 8 digit auto injector Six individual controlling heating areas Applications Used in quality supervision of medicines, foods and chemicals, oil extraction and refining industry, petrochemical industry, electronic high-purity gas industry and scientific research institutes.

6 Chromatography column type Chromatography column length Chromatography column diameter Temperature operating range Maximum programmed heating speed Programmed temperature steps Temperature setting precision Programmed heating rate The longest method run time Furnace dimension Heating area Detectors FID TCD FPD Capillary or Packed column 100 to 300 mm 0.2 to 0.5 mm C/min 7 steps C 0.1 to C/min (increment of C) min mm LGC-A11 Higher than the room temperature of 5 0 C to C, Liquid nitrogen cold trap: C to C, Dry ice cold trap: C to C Six individual controlling heating areas Maximum temperature in auxiliary heating area: C Following detectors can be selected as per the requirement Maximum using temperature: C Minimum LOD: 2.5 pg C/s [n-c16] Linear dynamic range: 10 7 (±10%) Data collection frequency: Maximum 100 Hz Maximum using temperature: C Minimum LOD: <400 pg C3H8 /ml (He) Linear dynamic range: 10 5 (±5%) Data collection frequency: Maximum 100 Hz Maximum using temperature: C Minimum LOD: <4 pg S/sec, <1 pg P/sec Linear dynamic range: >10 3 S, >10 4 P Optional: 10 5 g S/g C, 10 6 g P/g C

7 LGC-A11 ECD Maximum using temperature: C Type of gas compensation detector: 5% methane, argon, nitrogen Minimum LOD: >10 7 S, >10 7 P Linear dynamic range: Data collection frequency: Maximum 100 Hz Radioactive source: <12 m Ci 63Ni NPD Maximum using temperature: C Minimum LOD: <0.2 pg N/sec, <0.2 pg P/sec Minimum LOQ: < 3 pg/sec Linear dynamic range: 10 5 N, 10 5 P

Gas Chromatography www.labtron.com info@labtron.com LGC-A10 - ually controls the temperature of the system. This gas chromatography comes with packed column injectors, split/split less injectors, capillary

More information

Agilent 6850 Series II Network GC System G2630A Performance Specifications

Agilent 6850 Series II Network GC System G2630A Performance Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 6850 Series II Network GC

More information

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System Chromatec Crystal 9000 Laboratory Gas Chromatography System GC Chromatec-Crystal 9000 Crystal 9000 is a leading gas chromatograph in Chromatec GC product line. Crystal 9000 has highest performances and

More information

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Detection of Sulfur Compounds in Natural Gas According to ASTM D554 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector Application Note Author Rebecca Veeneman Abstract Sulfur compounds in natural

More information

DANI Transformer Oil Gas Analyzer

DANI Transformer Oil Gas Analyzer DANI Transformer Oil Gas Analyzer APPLICATION NOTE - AN169 Introduction Transformers are electrical devices used for energy transfer by electromagnetic induction between two or more circuits. Large oil

More information

S-PRO 3200 GC System for Sulfur Analysis

S-PRO 3200 GC System for Sulfur Analysis S-PRO 32 GC System for Sulfur Analysis Superior Selectivity and Sensitivity The ability to detect and measure sulfur contaminants in gases is critically important for efficient operation of industrial

More information

C2, C3, C4 Monomer Analysis

C2, C3, C4 Monomer Analysis C2, C3, C4 Monomer Analysis Malgorzata Sierocinska Agilent Technologies Waldbronn Page 1 Why Analyze Monomers? To Insure Consistent Production of High Quality Polymer Protect against food contamination

More information

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC Fast GC SPEEDY GC Slide 4 Optimization Goals Primary: Minimize time for the separation of a given number of peaks Secondary: Maximize the number of peaks separated by a given column Slide 5 HOW CAN THESE

More information

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors Model 8610C Gas Chromatograph Mounts up to Six Detectors and Five Injectors Ambient to 400 C Temperature Programmable Column Ovens Dimensions: 19 wide x 13.5 high x 14.5 deep Implement virtually any EPA

More information

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Refinery Gas Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Refinery Gas Analysis Reliability Placing refinery gas analyzers in the field for over

More information

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams Sulfur Detection at ppb Levels in Light Hydrocarbon Streams Based on a New Super Permeable PLOT Column Agilent Select Low Sulfur Johan Kuipers Channel Training Specialist Oct 12 th, 2010 1 October 18,

More information

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases Liquefied Gas Injector Solution for the Sampling and Analysis of Liquefied Gases Safe and Representative Sampling of Liquefied Gases The analysis of impurities and contaminants in liquefied gases is an

More information

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis Page 1 Alternate Carrier Gas Considerations and Faster GC Analysis Faster GC Total Analytical Cycle Times A Variety of Approaches Pre-Run ALS Set-Up Chromatographic Run Post-Run Bake-Out Post-Run Cool-Down

More information

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Authors: The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Introduction Specification of the hydrocarbon composition of LPG is required as traces

More information

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons   Gases C-C Hydrocarbons C-C Paraffins. Methane. Carbon Dioxide. Ethylene. Ethane. Acetylene. Methane (0.9%). Ethane (0.09%). Propane (0.099%). Isobutane (0.09%). Butane (0.09%). n-pentane (0.00%) Column: ft x

More information

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter Cd The Chrom Doctor Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter Jaap de Zeeuw, Restek Corporation, Middelburg, The Netherlands. In Part 1 of this series we focused

More information

ANTEK APPLICATED Turn-Key GC solutions

ANTEK APPLICATED Turn-Key GC solutions ANTEK APPLICATED Turn-Key GC solutions The ANTEK advantage Antek patents chemiluminescent nitrogen detection apparatus & method Antek introduces first total nitrogen chemiluminescence analyzer Antek opens

More information

GC Instruments GC Columns GC Accessories

GC Instruments GC Columns GC Accessories GC GC Instruments................. 200 212 GC Systems & Data Collection........... 200 205 Gas Generators Hydrogen......................... 206 207 Air............................ 208 209 Nitrogen............................

More information

Beverage Grade Carbon Dioxide

Beverage Grade Carbon Dioxide Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION The Challenge Carbon dioxide, used in the production of carbonated soft drinks and other beverages,

More information

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Application Note Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Authors Kelly Beard and James McCurry Agilent Technologies, Inc. Abstract An Agilent

More information

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 129 Infinity II HDR-DAD Impurity Analyzer Solution Application ote Small Molecule Pharmaceuticals Author Sonja Schneider Agilent Technologies,

More information

GC Method Compliance and Large Valve Oven Application

GC Method Compliance and Large Valve Oven Application GC Method Compliance and Large Valve Oven Application Solution Focused Kelly Beard June 20, 2016 Compliant Methods Compliant Methods What are our options? Analyzers and Analyzer Kits High Volume Well Known

More information

Deans Switch Microfluidics

Deans Switch Microfluidics TRACE 1300 and TRACE 1310 Gas Chromatographs Deans Switch Microfluidics Installation Guide 31709740 Revision A June 2014 2014 Thermo Fisher Scientific Inc. All rights reserved. TRACE 1300, and TRACE 1310

More information

Setting up SilFlow for BackFlush in your GC

Setting up SilFlow for BackFlush in your GC Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile

More information

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography Dr. Robert Lorenz Analytical Chemist Chevron Energy Technology Company Gulf Coast Conference Galveston, TX October

More information

CP-3800 GAS CHROMATOGRAPH

CP-3800 GAS CHROMATOGRAPH CP-3800 GAS CHROMATOGRAPH P/N 03-914689-00 Rev 4 TABLE OF CONTENTS I. GC OPERATION... 2 Overview... 2 Instrument Setup... 3 Building a Method... 4 Automation... 5 Activating the GC Method... 5 Making a

More information

Closed Cup Flash Point Tester

Closed Cup Flash Point Tester www.labtron.com info@labtron.com We have distinguished ranges of Closed Cup Flash Point Tester especially designed to offer highest level of accuracy and quality giving a versatility in the capacity and

More information

6890 Installing ¼ Glass Columns

6890 Installing ¼ Glass Columns 6890 Installing ¼ Glass Columns A15891 This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this material. The information

More information

Agilent 7890 Series Gas Chromatograph

Agilent 7890 Series Gas Chromatograph Agilent 7890 Series Gas Chromatograph Troubleshooting Agilent Technologies Notices Agilent Technologies, Inc. 2013 No part of this manual may be reproduced in any form or by any means (including electronic

More information

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in

More information

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC Technical Overview Trace gas analysis is a challenge in today s world. The ability to analyze lower component

More information

Using the PSD for Backflushing on the Agilent 8890 GC System

Using the PSD for Backflushing on the Agilent 8890 GC System Application Note Petrochemicals Using the PSD for Backflushing on the Agilent 889 GC System Author Brian Fitz Agilent Technologies, Inc. Wilmington, DE, USA. Abstract An Agilent 889 series GC equipped

More information

I SO9001 I SO14001 CE

I SO9001 I SO14001 CE I SO900 I SO400 CE ZHEJIANG FULI ANALYTICAL INSTRUMENT CO., LTD. Address : South Baizhang Road, Economic Development Zone, Wenling City, Taizhou, Z he ji ang Province, P. R. China Zip: 37500 Tel : 0086-576

More information

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS Agilent Portfolio Luca Godina Technical Marketing Specialist GC-GCMS 1 Summary Introduction Sample Prep Sample Introduction Inlets 7890B LTM CFT Detectors Special Solutions 13/11/12 Tirana Page 2 Agilent

More information

Mistral LC-MS Evolution Specification

Mistral LC-MS Evolution Specification Mistral LC-MS Evolution Specification Flow Rate: Outlet Pressure: Purity : Power Consumption : Circuit Breaker: Pressure accuracy : Microprocessor controlled display : Operating conditions : temperature

More information

performance productivity reliability

performance productivity reliability Solutions that meet your demands for: performance productivity reliability Excellent Choices for Global Hydrocarbon Processing Applications Crude Oil & Natural Gas Natural Gas > Return to Table of Contents

More information

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis Introduction Petroleum & Petrochemical Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis By Katarina Oden, Barry Burger, and Amanda Rigdon Crude oil consists of thousands of different

More information

Technical Procedure for Gas Chromatography (GC-FID)

Technical Procedure for Gas Chromatography (GC-FID) Technical Procedure for Gas Chromatography (GC-FID) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph (GC- FID). 2.0 Scope This procedure applies to all

More information

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application 7890A/7890B GC Overview October 29, 2014 1 Definitions Carrier Gas Pressurized gas used to transport the sample through the system.

More information

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR 6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR A15836 This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use

More information

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities : What Are You Willing To Do? Daron Decker Chromatography Technical Specialist Page 1 Agilent Restricted 3 Options Same Column and Gas Type Try Different/Faster Velocities Same Column, Switch He to H2

More information

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS TURN-KEY ANALYZERS GC SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS BROAD ARRAY BROAD OF ARRAY OF CONFIGURATIONS FOR FOR SPECIAL APPLICATIONS SPECIAL THE THE PERFECT ANSWER TO A SEVERELY TO REGULATED A SEVERELY

More information

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Simulated Distillation Analyzers, Software, Standards, Consumables, Training Simulated Distillation Analyzers, Software, Standards, Consumables, Training www.separationsystems.com Offering the Fullest Range of Optimized Solutions Simulated distillation (SimDis) has been used to

More information

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS)

SPECIFICATION. Bench top triple quadrupole Mass Spectrometry System coupled to a gas performance Chromatography (GC-MS/MS) SPECIFICATION Bench top triple quadrupole Mass performance Chromatography (GC-MS/MS) 1. Scope These specifications describe the requirements for a bench top triple quadrupole mass spectrometry system coupled

More information

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS

Ultra Clean Gas Filters Reference Guide ULTRA CLEAN GAS FILTERS ULTRA CLEAN GAS FILTERS ULTRA CLEAN GAS FILTERS Table of Contents Ultra Clean Gas Filter s for GC and GC/MS...3 Triple Filter for MS/ECD/NPD... 3 Complete Triple Filter Bundle for FID...3 Complete Triple

More information

Choose for Your Instrument

Choose for Your Instrument Choose for Your Instrument GC Supplies - Instrument Quick Pick Guide Agilent Technologies Bruker/Scion (Varian) PerkinElmer Shimadzu Thermo Scientific GC Supplies - Instrument Quick Pick Guide Choose for

More information

Method Development for Capillary GC Systems. Slide 1

Method Development for Capillary GC Systems. Slide 1 Method Development for Capillary GC Systems Slide 1 AREAS TO OPTIMIZE Injector Carrier gas Column temperature Slide 2 COMMON INJECTOR MODES Vaporization Injection Modes Megabore Direct Split Splitless

More information

Agilent 7693A Automated Liquid Sampler

Agilent 7693A Automated Liquid Sampler Agilent 7693A Automated Liquid Sampler Specifications Overview The Agilent 7693A is a state-of-the-art sample handling and injection system that provides the highest levels of precision and reliability

More information

Application Note. Abstract. Authors. Environmental Analysis

Application Note. Abstract. Authors. Environmental Analysis High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID using the Agilent Low Thermal Mass (LTM II) System Application Note Environmental Analysis Authors Frank David and Karine Jacq Research

More information

Experience the Difference

Experience the Difference ABB-Totalflow Experience the Difference PGC1000 Process Gas Chromatograph ABB Group October 19, 2011 Slide 1 Process GC Experience ABB introduced the Btu-8000 in 1995 C6+ application suitable for custody

More information

Agilent Multimode Inlet for Gas Chromatography

Agilent Multimode Inlet for Gas Chromatography Agilent Multimode Inlet for Gas Chromatography Technical Note Agilent Multimode Inlet for the 7890A GC Designed to give you ease of use and maximum flexibility, the Agilent Multimode Inlet does everything

More information

Agilent 7820A Gas Chromatograph

Agilent 7820A Gas Chromatograph Agilent 7820A Gas Chromatograph Illustrated Parts Breakdown 15 Illustrated Parts Breakdown Overview of the IPB 297 Inlets 298 Detectors 316 EPC modules 357 Nickel catalyst accessory 365 Covers 369 Automatic

More information

Refrigerated. Centrifuge.

Refrigerated. Centrifuge. Refrigerated Centrifuge info@labtron.com www.labtron.com Refrigerated centrifuge LRF-A1 Series We deliver a wide range of refrigerated centrifuge for a large variety of samples. This equipment is ideal

More information

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis Now with New Dual Plasma Technology Overview The Agilent Technologies

More information

Agilent and ASTM. Update on Recent Activities. Page 1

Agilent and ASTM. Update on Recent Activities. Page 1 Agilent and ASTM Update on Recent Activities Page 1 ASTM Committees for Refining, Fuels, Petroelum Products ASTM International D2 Petroleum products & lubricants D3 Gas fuels (natural gas) gas fuels D16

More information

Antek Gas Chromatography Products: A Guided Tour Through Industry

Antek Gas Chromatography Products: A Guided Tour Through Industry ANTEK GC Application Solutions Feature the Following Detectors: Antek Sulfur and Nitrogen Chemiluminescence, Flame Ionization, Thermal Conductivity, Nitrogen-Phosphorus, Atomic Emission, Halogen Specific,

More information

Application. Gas Chromatography June 1995

Application. Gas Chromatography June 1995 Determining Oxygenates in Gasoline: ASTM Method D Application Gas Chromatography June 99 Authors Michael J. Szelewski Agilent Technologies, Inc. 0 Centerville Road Wilmington, DE 90-60 USA Matthew S. Klee

More information

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X GC Best Practices & Troubleshooting Group/Presentation Title Agilent Restricted Month ##, 200X Troubleshooting Tips 1. Isolate the problem. (Blank Runs, Inject Un-retained Compound, Know what it is not)

More information

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent

More information

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. PGC1000 Meeting the needs of NGL plants

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. PGC1000 Meeting the needs of NGL plants ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT PGC1000 Meeting the needs of NGL plants P G C 1 0 0 0 N G L P L A N T P R O D U C T I O N P B/ 1 0 74 3 - E N Measurement made easy PGC1000 NGL PLANT

More information

29 Installation Step 1. Unpacking the GC Cable diagrams Step 2. Placing the GC system on the benchtop Step 3. Turning the power on

29 Installation Step 1. Unpacking the GC Cable diagrams Step 2. Placing the GC system on the benchtop Step 3. Turning the power on 29 Installation Step 1. Unpacking the GC Step 2. Placing the GC system on the benchtop Step 3. Turning the power on Step 4. Connecting tubing to the gas supply tank Step 5. Attaching traps to the gas supply

More information

THC Heated FID 3-300A

THC Heated FID 3-300A Rack Mount/Table Top TVOC Analyzer THC Heated FID 3-300A Space saving 19"/3PU space saving rack mount and table top heated emission analyzer for the continuous determination of the mass concentration of

More information

ii) PC based works station with monitor and printer having below mentioned specifications:

ii) PC based works station with monitor and printer having below mentioned specifications: GAS CHROMATOGRAPH ANNEXURE-A Gas with TCD,FID & Methanizer as below for NFL Bhatinda, Panipat & Nangal Unit (one each): i)gas customized & factory fitted capable of concurrent (parallel) operations of

More information

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry Shimadzu Customized GC Analyzers GC-2010 Plus Nexis GC-2030 GC-2014 Natural Gas

More information

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D7423-09 using AC OXYTRACER Fast Analysis in

More information

INTEREST OF HPTLC FOR FOSSIL DERIVED PRODUCTS ANALYSIS : A SIMPLE APPROACH TO HYDROCARBON GROUP TYPE ANALYSIS

INTEREST OF HPTLC FOR FOSSIL DERIVED PRODUCTS ANALYSIS : A SIMPLE APPROACH TO HYDROCARBON GROUP TYPE ANALYSIS INTEREST OF HPTLC FOR FOSSIL DERIVED PRODUCTS ANALYSIS : A SIMPLE APPROACH TO HYDROCARBON GROUP TYPE ANALYSIS Muriel Matt 1,2, Vicente L. Cebolla 1, Luis Membrado 1, Eva M. Galvez 1, Jesus Vela 1, Robert

More information

Agilent 6890 Gas Chromatograph

Agilent 6890 Gas Chromatograph Agilent 6890 Gas Chromatograph Maintaining Your GC Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D759 Application Petrochemical Author James D. McCurry Agilent Technologies 285 Centerville

More information

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA PET 01 - PETROLEUM ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA GASOLINE RANGE HYDROCARBONS Column Part No.: 054950 BP1, PONA 50 m x 0.15 mm ID Initial Temp.: 30 C, 5 min hold Rate 1: 2 C/min Temp.

More information

Installing a Purged Packed Inlet

Installing a Purged Packed Inlet Installing a Purged Packed Inlet Agilent 6850 Gas Chromatograph This kit contains: Accessory G2651A Description Purged packed column inlet system 1 Top block insulation 1 Bottom block insulation 1 Insulation

More information

HIGH PRESSURE SUPERCRITICAL CARBON DIOXIDE EFFICIENCY IN REMOVING HYDROCARBON MACHINE COOLANTS FROM METAL COUPONS AND COMPONENTS PARTS

HIGH PRESSURE SUPERCRITICAL CARBON DIOXIDE EFFICIENCY IN REMOVING HYDROCARBON MACHINE COOLANTS FROM METAL COUPONS AND COMPONENTS PARTS 101 HIGH PRESSURE SUPERCRITICAL CARBON DIOXIDE EFFICIENCY IN REMOVING HYDROCARBON MACHINE COOLANTS FROM METAL COUPONS AND COMPONENTS PARTS Robert F. Salerno Organic MateriaUSurface Modification EG&G Mound

More information

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer Technical Offer Antek Model 6200 Analyzer 2015.4 Determine Total Sulfur and Total Nitrogen in a single analyzer Meet sulfur regulations and control your process with continuous sulfur and/or nitrogen measurements

More information

HIGH SPEED CENTRIFUGE

HIGH SPEED CENTRIFUGE HIGH SPEED CENTRIFUGE info@labtron.com www.labtron.com High Speed Centrifuge LHS-A10 High Speed Centrifuge LHS-A10 is a microprocessor controlled light weight table top type system with an advanced design

More information

Mineral Turpentine Adulterant in Lubricating Oil

Mineral Turpentine Adulterant in Lubricating Oil DOI:10.7598/cst2015.1095 Chemical Science Transactions ISSN:2278-3458 2015, 4(4), 975-980 RESEARCH ARTICLE Mineral Turpentine Adulterant in Lubricating Oil RAGHUNATH TOCHE 1, SHOBHA BORADE 2, MADHUKAR

More information

SUPPORTING INFORMATION

SUPPORTING INFORMATION SUPPORTING INFORMATION For Comparative Analysis of Halonitromethane and Trihalomethane Formation and Speciation in Drinking Water: The effects of Disinfectants,, Bromide, and Nitrite Jia Hu a, Hocheol

More information

Installing a Purged Packed (PP) Inlet

Installing a Purged Packed (PP) Inlet Installing a Purged Packed (PP) Inlet Agilent 6850 Gas Chromatograph Accessory G2651A These instructions are divided into two parts: Part 1 to prepare the Electronic Pressure Control ("EPC") module for

More information

Thermo Scientific TRACE GC Ultra Multi-channel gas chromatograph. Performance Beyond Limits

Thermo Scientific TRACE GC Ultra Multi-channel gas chromatograph. Performance Beyond Limits c h r o m a t o g r a p h y Thermo Scientific TRACE GC Ultra Multi-channel gas chromatograph Performance Beyond Limits Innovative advances for unprecedented reliability and productivity Ultra in system

More information

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS FLASH VAPORISATION INJECTION Split Splitless On-Column COOL INJECTION Large Volume Injection (LVI) On-Column On-Column-SVE (with solvent vapour

More information

Analysis of Petroleum Fractions by ASTM D2887

Analysis of Petroleum Fractions by ASTM D2887 Analysis of Petroleum Fractions by ASTM D2887 Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 2582 Key Words Simulated distillation, D2887, TRACE TR-SimDist Abstract ASTM

More information

DIONEX ELUENT GENERATOR CARTRIDGE DIONEX EGC 500 K 2 CO 3 HIGH PRESSURE ELECTROLYTIC PH MODIFIER (DIONEX EPM 500) Quick Start

DIONEX ELUENT GENERATOR CARTRIDGE DIONEX EGC 500 K 2 CO 3 HIGH PRESSURE ELECTROLYTIC PH MODIFIER (DIONEX EPM 500) Quick Start DIONEX ELUENT GENERATOR CARTRIDGE DIONEX HIGH PRESSURE ELECTROLYTIC PH MODIFIER (DIONEX EPM 500) Quick Start 1. Preparation for Installation of Dionex If installing a Thermo Scientific Dionex and Thermo

More information

4001 Transesterification of castor oil to ricinoleic acid methyl ester

4001 Transesterification of castor oil to ricinoleic acid methyl ester 4001 Transesterification of castor oil to ricinoleic acid methyl ester castor oil + MeH Na-methylate H Me CH 4 (32.0) C 19 H 36 3 (312.5) Classification Reaction types and substance classes reaction of

More information

HIGH SPEED CENTRIFUGE

HIGH SPEED CENTRIFUGE HIGH SPEED CENTRIFUGE info@labtron.com www.labtron.com High Speed Centrifuge LH S-A10 High Speed Centrifuge LHS-A10 is a microprocessor controlled light weight table top type system with an advanced design

More information

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System Application Note Authors Frank David Research Institute for Chromatography, Pres.

More information

Service Manual. Agilent G2350A Atomic Emission Detector. Released: MAY 2000 G2350A AED Service Manual 1

Service Manual. Agilent G2350A Atomic Emission Detector. Released: MAY 2000 G2350A AED Service Manual 1 Service Manual Agilent G2350A Atomic Emission Detector Released: MAY 2000 G2350A AED Service Manual 1 Copyright Agilent Technologies 2000 All Rights Reserved. Reproduction, adaptation, or translation without

More information

Is there still a need for selective GC detectors?

Is there still a need for selective GC detectors? Is there still a need for selective GC detectors? M Ramesh Application Engg Agilent Technologies India Pvt Ltd. Outline GC Detectors Available from Agilent Electron Capture Detector (ECD) Nitrogen Phosphorus

More information

Agilent 7693A Automated Liquid Sampler

Agilent 7693A Automated Liquid Sampler IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 7693A Automated Liquid Sampler

More information

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY Extended range HPLC has been investigated for many years; however, progress was delayed because of

More information

Stability, Linearity and Repeatability of Nitrogen Determination by Flash Combustion using Argon as Carrier Gas

Stability, Linearity and Repeatability of Nitrogen Determination by Flash Combustion using Argon as Carrier Gas Stability, Linearity and Repeatability of Nitrogen Determination by Flash Combustion using Argon as Carrier Gas Liliana Krotz, Walter Galotta, and Guido Giazzi Thermo Fisher Scientific, Milan, Italy Overview

More information

Status Report of the VIAQ (Vehicle Interior Air Quality) Informal Working Group

Status Report of the VIAQ (Vehicle Interior Air Quality) Informal Working Group Transmitted by the Chair and Secretary of VIAQ Informal document GRPE-78-29 78 th GRPE, 8-11 January 2019 Agenda item 12 Status Report of the VIAQ () GENEVA, January 9th 2019 Chair: Andrey KOZLOV, Russian

More information

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application Authors Steven M. Wilbur and Emmett Soffey Agilent Technologies 338 146th Place SE Bellevue,

More information

ASTM D 6730 Detailed Hydrocarbon Analysis

ASTM D 6730 Detailed Hydrocarbon Analysis ASTM D 6730 Detailed Hydrocarbon Analysis Jaap de Zeeuw, Jan Pijpelink and Barry Burger Restek Corporation ASTM D 6730-01(2006)e1 Determination of Individual Components in Spark Ignition Engine Fuels as

More information

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC Application Note Energy and Fuels Authors Detlef Wilhelm Anatox GmbH & Co. KG Fürstenwalde, Germany Udo Huber Agilent

More information

ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE

ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE + INGRID CITY GATE STATION INGRID GAS CONTROL CENTER What is? H2 INJECTION is a modular multi-function system based on:, A NEW METHOD OF MANAGING THE

More information

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels James D. McCurry Senior Scientist Agilent Technologies Wilmington, DE USA Page 1 Application Summary There is a need to measure

More information

Thermo Scientific. TRACE GC Ultra UFM. Ultra Fast Module Device Instruction Manual. PN , Revision May 2010

Thermo Scientific. TRACE GC Ultra UFM. Ultra Fast Module Device Instruction Manual. PN , Revision May 2010 Thermo Scientific TRACE GC Ultra UFM Ultra Fast Module Device Instruction Manual PN 31709398, Revision May 2010 UFM Ultra Fast Module Device for TRACE GC Ultra Instruction Manual May 2010 Edition Part

More information

Rosemount Analytical Model 500 Process Gas Chromatograph

Rosemount Analytical Model 500 Process Gas Chromatograph 71-RAI-PGC-PDS-Model500 Product Data Sheet Rosemount Analytical Model 500 Process Gas Chromatograph The Model 500 Process Gas Chromatograph is an advanced combination of technology and rugged instrumentation

More information

GC-101. Testing of Biodiesel Using Gas Chromatography. by Bob Armantrout. Presented at: Local Biodiesel: A Biodiesel Coop Conference

GC-101. Testing of Biodiesel Using Gas Chromatography. by Bob Armantrout. Presented at: Local Biodiesel: A Biodiesel Coop Conference GC-101 Testing of Biodiesel Using Gas Chromatography by Bob Armantrout (Image Research Machines plc) Presented at: Local Biodiesel: A Biodiesel Coop Conference Strategies For Community-based Biodiesel

More information

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS AppNote 6/26 Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) Andreas Hoffmann GERSTEL GmbH & Co.KG, Eberhard-Gerstel-Platz 1,

More information

GC Instruments GC Columns GC Accessories

GC Instruments GC Columns GC Accessories GC GC Instruments................. 200 212 GC Systems & Data Collection........... 200 205 Gas Generators Hydrogen......................... 206 207 Air............................ 208 209 Nitrogen............................

More information

Agilent G3348B Flame Photometric Detector

Agilent G3348B Flame Photometric Detector Agilent G3348B Flame Photometric Detector For Agilent 6850 GC Installation and Operation Agilent Technologies Notices Agilent Technologies, Inc. 2005 No part of this manual may be reproduced in any form

More information