1 Choose for Your Instrument GC Supplies - Instrument Quick Pick Guide Agilent Technologies Bruker/Scion (Varian) PerkinElmer Shimadzu Thermo Scientific

2 GC Supplies - Instrument Quick Pick Guide Choose for Your Instrument Your chromatography analysis does not end with the selection of the GC column. The combination of components selected for your instrument also make an important contribution to successful separations. Choose SGE to improve your chromatography. Sample Introduction Syringes The SGE Diamond Syringe Range offers significantly improved levels of durability, clarity and accuracy. SGE manual and autosampler syringes are designed for optimal sample introduction. Choose from a comprehensive range of syringe options including plunger protection, removable or fixed needles, a range of needle gauge and length options as well as needle-tip style alternatives. Sample Introduction Septa The role of septa for GC analysis is key as many chromatographic problems are caused by use of inappropriate septa material or inappropriate handling of the septa. Desired septa attributes: Reliably seal against the carrier gas pressure in the inlet. Capable of being pierced and resealed time after time. Capable of being pierced by the syringe needle without pieces being deposited in the GC inlet system. Must not contaminate or bleed material into the chromatographic system. Sample Introduction GC Inlet Liners The GC Inlet liner is where the sample is introduced and vaporized into the gaseous phase. The design of the liner is crucial, as is liner deactivation, to ensure reproducible and accurate chromatography. Sample Introduction GC Connections (ferrules and fittings) SGE GC Connections are designed to minimize time spent on installation, and are suitable for a wide range of applications. Poorly defined or selected connections can lead to an increase in dead volume, leaks and mismatched tubing sizes after temperature cycling.

3 Contents Agilent Technologies 4-7 Bruker/Scion (Varian) 8-11 PerkinElmer Shimadzu Thermo Scientific Expert Tips Choose SGE to improve your chromatography.

4 Agilent Technologies GC Supplies - Instrument Quick Pick Guide Autosampler Syringes All needles are 42 mm long with a cone tip. Agilent 7673, 7683, 7693A & 6850 ALS Volume Needle Gauge (OD mm) Fixed Dual Gauge Needle 23-26s 5 µl (0.63/0.47) 23-26s 10 µl (0.63/0.47) 23-26s 10 µl Gas Tight (0.63/0.47) Fixed Straight Needle Syringe Code Syringe Spare Needle Spare Plunger 5F-AG-0.63/0.47C F-AG-0.63/0.47C F-AG-GT-0.63/0.47C µl 26 (0.47) 5F-AG-0.47C µl (m) 23 (0.63) 5F-AG-0.63C µl 26 (0.47) 10F-AG-0.47C µl (m) 23 (0.63) 10F-AG-0.63C µl (m) Gas Tight 23 (0.63) 10F-AG-GT-0.63C Removable Dual Gauge Needle 23-26s 0.5 µl (0.63/0.47) 23-26s 10 µl Gas Tight (0.63/0.47) Removable Straight Needle 0.5BR-AG-0.63/0.47C * 10R-AG-GT-0.63/0.47C µl 26 (0.47) 0.5BR-AG-0.47C * 0.5 µl (m) 23 (0.63) 0.5BR-AG-0.63C * 1 µl 23 (0.63) 1BR-AG-0.63C * 10 µl 26 (0.47) 10R-AG-0.47C µl (m) 23 (0.63) 10R-AG-0.63C (m) Suitable for use with the Merlin Microseal Injector. * Denotes Spare Needle and Plunger kit. 4

5 Septa Choose from a number of different septa types: GP = For non-demanding routine applications. EC = Combines significantly longer injection life, low bleed and low injection port adhesion. MN = Premium septa for autosamplers, up to 400 injections per septum. HT = Bleed and temperature optimized, combined with outstanding mechanical properties. Type Material Durability Resealing Solvent Resistance Tear Resistance Maximum Temperature GP Silicone Good Good Excellent Good 200 C EC High Temperature Silicone Excellent Excellent Excellent Excellent 400 C MN High Temperature Silicone Excellent Excellent Excellent Excellent 400 C HT BTO Silicone Excellent Excellent Excellent Excellent 400 C Diameter Type For Agilent 7620, 5790, 5880, GP MN For Agilent 5700, 5800, GP EC HT For Agilent 7890, 6890,5890, 5880, 4890, GP EC MN HT For Agilent 5750, 710, 720, 810, GP HT EC

6 Agilent Technologies GC Supplies - Instrument Quick Pick Guide Inlet Liners Description and Geometry For Agilent 5890, 6850, 6890, 7890 and HP4890 Split / Splitless FocusLiner Split / Splitless Taper FocusLiner Split / Splitless FAST FocusLiner Split / Splitless Tapered FAST FocusLiner OD ID Length ConnecTite Liner Standard ConnecTite Liner Top Hole ConnecTite Liner Bottom Hole Split, Straight-through Liner Split, with Quartz Wool Split / Splitless with Single Taper Split / Splitless with Single Taper (Quartz Wool) Split / Splitless with Double Taper Direct, Straight-through Liner Split / Splitless Quartz, Straight-through Liner Splitless with Recessed Gooseneck Split / Splitless Recessed Gooseneck (Quartz Wool) Taper / Gooseneck FocusLiner Taper FocusLiner ConnecTite Straight Double Taper PTV/LVI O-rings and Sealing Rings Description Usage Viton O-ring Temperatures up to 300 C. Suitable for liners with OD of 6.3 mm Graphite Sealing Ring Temperatures up to 450 C. Suitable for all inlet liners above except and Graphite Sealing Ring Temperatures up to 450 C. Suitable for use with liners and

7 SilTite FingerTite Ferrules Description Column ID Ferrule ID SilTite Fingertite Agilent INJ / FID Kit mm 0.4 mm * SilTite FingerTite Agilent Capillary / FID Kit mm 0.4 mm * SilTite FingerTite Agilent INJ / MS Kit mm 0.4 mm * SilTite FingerTite Agilent INJ / FID Kit 0.53 mm 0.7 mm * SilTite FingerTite Agilent Injector Kit 0.53 mm 0.7 mm * SilTite FingerTite Agilent Capillary / FID Kit 0.53 mm 0.7 mm * SilTite FingerTite Agilent Capillary Injector Kit 0.53 mm 0.7 mm * Replacement Parts SilTite FingerTite Ferrule 0.4 mm mm 0.4 mm SilTite FingerTite Ferrule 0.5 mm 0.32 mm 0.5 mm SilTite FingerTite Ferrule 0.7 mm 0.53 mm 0.7 mm SilTite FingerTite Blanking Ferrule SilTite FingerTite Female Nut SilTite FingerTite INJ Base Seal mm SilTite FingerTite INJ Base Seal 0.53 mm SilTite FingerTite Capillary Adaptor SilTite FingerTite MS Adaptor SilTite FingerTite FID Detector SilTite FingerTite Injector mm * Each starter kit includes all the parts necessary to convert one GC system (one injector and one detector) to the SilTite FingerTite system. In addition there are five SilTite FingerTite nuts, ten SilTite FingerTite ferrules, and a ferrule install tool which allows you to seat the ferrule in the correct position on the capillary column. Ferrules Instrument Column ID Ferrule ID 15% Graphite / 85% Vespel Ferrules Injectors & Detectors at atmospheric pressure e.g. FID GC-MS Interface Connection 100% Graphite Ferrules Injectors & Detectors at atmospheric pressure e.g. FID (Not for GC-MS) mm 0.4 mm mm 0.5 mm mm 0.8 mm for 1/8" OD ed Columns 1/8" for 1/4" OD ed Columns 1/4" mm 0.4 mm mm 0.5 mm mm 0.8 mm mm 0.5 mm mm 0.8 mm for 1/8" OD ed Columns 1/8" for 1/4" OD ed Columns 1/4" SilTite Metal Ferrules mm 0.4 mm 10* GC-MS Interface Connection (Starter Kit) 0.32 mm 0.5 mm 10* mm 0.8 mm 10* mm 0.4 mm 10 # Split / Splitless Injectors (Starter Kit) 0.32 mm 0.5 mm 10 # mm 0.8 mm 10 # /32" 0.81 mm 10 # Replacement SilTite Metal Ferrules mm 0.4 mm All Connections 0.32 mm 0.5 mm mm 0.8 mm /32" 0.81 mm Replacement SilTite Nuts GC-MS Interface Connection Split / Splitless Injector Replacement SilTite Base Seals Split / Splitless Injector * Includes ten ferrules, two SilTite nuts. # Includes ten ferrules, two SilTite nuts and two SilTite Inlet Base Seals. 7

8 Bruker/Scion (Varian) GC Supplies - Instrument Quick Pick Guide Autosampler Syringes Volume Length Needle Gauge (OD mm) Tip Style Syringe Code Syringe Needle Plunger Bruker/Scion (Varian) 8035, 8100 and 8200 Removable Needle 1 µl* (0.47) Cone 1BR-VA8X ** 10 µl Gas Tight (0.5) S/Hole 10R-GT-VA8X-II Needle Alternatives for P/N (0.5) Bevel N10-VA8035-II (0.63) S/Hole N10-VA8X00H-0.63-II (0.5) S/Hole N10-VA800H-II(0.2) Bruker/Scion (Varian) CP-8400/8410, CP-9010/9050 Fixed Needle 10 µl (0.47) Bevel 10F-VA8400-5/ µl (0.63) Cone 10F-VA8400/BT-5/0.63C Removable Needle 10 µl Gas Tight (0.47) Cone 10R-BT-GT-0.47C *Not suitable for 8200 autosampler. **Denotes Plunger and Needle Kit. Septa Choose from a number of different septa types: GP = For non-demanding routine applications. EC = Combines significantly longer injection life, low bleed and low injection port adhesion. MN = Premium septa for autosamplers, up to 400 injections per septum. HT = Bleed and temperature optimized, combined with outstanding mechanical properties. Type Material Durability Resealing Solvent Resistance Tear Resistance Maximum Temperature GP Silicone Good Good Excellent Good 200 C EC High Temperature Silicone Excellent Excellent Excellent Excellent 400 C MN High Temperature Silicone Excellent Excellent Excellent Excellent 400 C HT BTO Silicone Excellent Excellent Excellent Excellent 400 C Diameter Type For Varian / Bruker 1177 Injector 9 GP EC MN HT For Varian / Bruker 1040, 1041, 1060, 1061 injector 9.5 GP EC HT For Varian / Bruker 1040, 1041, 1060, 1061 injector 11 GP EC MN HT

9 Inlet Liners Description and Geometry For 1177 Injector Split / Splitless FocusLiner Split / Splitless Taper FocusLiner Split / Splitless FAST FocusLiner Split / Splitless Tapered FAST FocusLiner Split, straight-through liner Split, with quartz wool Split / Splitless with single taper Split / Splitless with single taper (quartz wool) Split / Splitless with double taper Direct, straight-through liner OD ID Length Splitless with Recessed Gooseneck Split / Splitless Recessed Gooseneck (quartz wool) For 1075/1077 Injector Split, FAST FocusLiner Split with Quartz Wool Split FocusLiner with Top-end Restriction Splitless FocusLiner with Top-end Restriction Split, Taper FocusLiner Splitless, Slots at Both Ends Split FocusLiner Taper / Gooseneck FocusLiner Taper FocusLiner ConnecTite Straight Double Taper PTV/LVI 9

10 Bruker/Scion (Varian) GC Supplies - Instrument Quick Pick Guide Inlet Liners Continued Description and Geometry For 1078/1079 Injector Sintered Glass, Large Volume Injection (LVI) Liner OD ID Length 5 1.8/ Straight-through Liner SPME liner Splitless with Single Taper Split / Splitless with Single Taper Split / Splitless FocusLiner Split / Splitless Taper FocusLiner For 1093/1094 Injector ConnecTite SPI Liner, (Restriction = 0.25 mm) ConnecTite SPI Liner, (Restriction = 0.5 mm) for 0.53 mm ID On-column ConnecTite SPI Liner, (Restriction = 0.25 mm) Taper / Gooseneck FocusLiner Taper FocusLiner ConnecTite Straight Double Taper PTV/LVI O-rings and Sealing Rings Description Usage Viton O-ring for 1177 Injector Temperatures up to 300 C Graphite Sealing Ring for 1075 & 1077 Injectors Temperatures up to 450 C Graphite Sealing Ring for 1078 & 1079 Injectors Temperatures up to 450 C

11 SilTite FingerTite Ferrules Description Column ID Ferrule ID SilTite FingerTite Bruker/Scion (Varian) Injector/GC-MS Kit mm 0.4 mm * SilTite FingerTite Bruker/Scion (Varian) Injector/FID Kit mm 0.4 mm * SilTite FingerTite Bruker/Scion (Varian) Injector/FID Kit 0.53 mm 0.7 mm * SilTite FingerTite Bruker/Scion (Varian) Injector Kit 0.53 mm 0.7 mm * Replacement Parts SilTite FingerTite Ferrule 0.4 mm mm 0.4 mm SilTite FingerTite Ferrule 0.5 mm 0.32 mm 0.5 mm SilTite FingerTite Ferrule 0.7 mm 0.53 mm 0.7 mm SilTite FingerTite Ferrule Blanking SilTite FingerTite Female Nut * Each starter kit includes all the parts necessary to convert one GC system (one injector and one detector) to the SilTite FingerTite system. In addition there are five SilTite FingerTite nuts, ten SilTite FingerTite ferrules, and a ferrule install tool which allows you to seat the ferrule in the correct position on the capillary column. Ferrules Instrument Column ID Ferrule ID 15% Graphite / 85% Vespel Ferrules mm 0.4 mm GC-MS & Detectors at atmospheric pressure e.g. FID 0.32 mm 0.5 mm mm 0.8 mm ed Columns 1/8" OD ed Columns 1/8" /4" OD ed Columns 1/4" % Graphite Ferrules mm 0.5 mm mm 0.8 mm Injectors & Detectors at atmospheric pressure e.g. FID 1/8" OD ed Columns 1/8" /4" OD ed Columns 1/4" SilTite Metal Ferrules mm 0.4 mm 10* GC-MS Interface Connections (Starter Kit) 0.32 mm 0.5 mm 10* mm 0.8 mm 10* Nuts for Varian Injector Replacement SilTite Ferrules mm 0.4 mm GC-MS Interface Connections 0.32 mm 0.5 mm mm 0.8 mm /32" 0.81 mm Replacement SilTite Nuts SilTite Metal Nuts *Includes ten ferrules, two SilTite nuts. 11

12 PerkinElmer GC Supplies - Instrument Quick Pick Guide Autosampler Syringes All needles are 70 mm long with a cone tip style. PerkinElmer AutoSystem Volume Needle Gauge (OD mm) Syringe Code Syringe Spare Needle Spare Plunger Fixed Needle 5 µl 26 (0.47) 5F-PE-0.47C µl 23 (0.63) 5F-PE-0.63C µl Gas Tight 26 (0.47) 5F-PE-GT-0.47C µl Gas Tight 23 (0.63) 5F-PE-GT-0.63C µl 23 (0.63) 50F-PE-0.63C Removable Needle 0.5 µl 26 (0.47) 0.5BR-PE-0.47C * 0.5 µl 23 (0.63) 0.5BR-PE-0.63C * *Denotes spare Needle and Plunger kit. Septa Choose from a number of different septa types: GP = For non-demanding routine applications. EC = Combines significantly longer injection life, low bleed and low injection port adhesion. MN = Premium septa for autosamplers, up to 400 injections per septum. HT = Bleed and temperature optimized, combined with outstanding mechanical properties. Type Material Durability Resealing Solvent Resistance Tear Resistance Maximum Temperature GP Silicone Good Good Excellent Good 200 C EC High Temperature Silicone Excellent Excellent Excellent Excellent 400 C MN High Temperature Silicone Excellent Excellent Excellent Excellent 400 C HT BTO Silicone Excellent Excellent Excellent Excellent 400 C Diameter Type For PerkinElmer Sigma, 900, 990, 8000 Series, AutoSystem and Clarus 11 GP EC MN HT

13 Inlet Liners Description and Geometry For AutoSystem & Clarus 500, 600 Split / Splitless Single Taper liner Split / Splitless FocusLiner Split / Splitless Taper FocusLiner Split, straight-through liner OD ID Length Splitless, straight-through liner Split / Splitless for PSS injector Split / Splitless FocusLiner for PSS injector Large Volume Injection (LVI) liner for PSS injector, sintered glass ed Column liner For 8000 and Sigma series Split / Splitless Splitless with single taper PTV Liner PTV liner with 0.25 mm ID restriction (recessed gooseneck) For AutoSystem Injectors ConnecTite Liner Standard ConnecTite Liner Top Hole ConnecTite Liner Bottom Hole Taper / Gooseneck FocusLiner Taper FocusLiner ConnecTite Straight Double Taper PTV/LVI O-rings and Sealing Rings Description Usage Viton O-ring Temperatures up to 300 C. For use with 6.2 mm OD liners Graphite Vespel Sealing Ring for PSS system Temperatures up to 325 C. For use with 4 mm OD liners

14 PerkinElmer GC Supplies - Instrument Quick Pick Guide SilTite FingerTite Ferrules Description Column ID Ferrule ID SilTite FingerTite PerkinElmer Injector/GC-MS Starter Kit mm 0.4 mm * SilTite FingerTite PerkinElmer Injector/FID Starter Kit mm 0.4 mm * SilTite FingerTite PerkinElmer Injector/FID Starter Kit 0.53 mm 0.7 mm * SilTite FingerTite PerkinElmer Injector Starter Kit 0.53 mm 0.7 mm * Replacement Parts SilTite FingerTite Ferrule 0.4 mm mm 0.4 mm SilTite FingerTite Ferrule 0.5 mm 0.32 mm 0.5 mm SilTite FingerTite Ferrule 0.7 mm 0.53 mm 0.7 mm SilTite FingerTite Ferrule Blanking SilTite FingerTite Female Nut * Each starter kit includes all the parts necessary to convert one GC system (one injector and one detector) to the SilTite FingerTite system. In addition there are five SilTite FingerTite nuts, ten SilTite FingerTite ferrules, and a ferrule install tool which allows you to seat the ferrule in the correct position on the capillary column. Ferrules Instrument Column ID of Nut Ferrule ID 15% Graphite / 85% Vespel Ferrules mm 1/16" 0.4 mm mm 1/8" 0.4 mm mm 1/16" 0.5 mm For Injectors & Detectors at 0.32 mm 1/8" 0.5 mm atmospheric pressure e.g. FID mm 1/16" 0.8 mm mm 1/8" 0.8 mm /8" OD ed Columns 1/8" 1/8" /4" OD ed Columns 1/4" 1/4" % Graphite Ferrules mm 1/16" 0.5 mm mm 1/8" 0.5 mm For Injectors & Detectors at mm 1/16" 0.8 mm atmospheric pressure e.g. FID (Not for GC-MS) mm 1/8" 0.8 mm /8" OD ed Columns 1/8" 1/8" /4" OD ed Columns 1/4" 1/4" SilTite Metal Ferrules mm 0.4 mm 10* For GC-MS Interface Connection (Starter Kit) 0.32 mm 0.5 mm 10* mm 0.8 mm 10* Replacement SilTite Ferrules mm 0.4 mm For GC-MS Interface Connection 0.32 mm 0.5 mm mm 0.8 mm /32" 0.81 mm Replacement SilTite Nuts Replacement SilTite Nuts *Includes ten ferrules, two SilTite nuts. 14

15 Shimadzu GC Supplies - Instrument Quick Pick Guide Autosampler Syringes All needles are 42 mm long with a cone tip style. Shimadzu AOC14, AOC17 and AOC20 Volume Needle Gauge (OD mm) Syringe Code Syringe Spare Needle Spare Plunger Fixed Needle 5 µl 23 (0.63) 5F-S-0.63C Removable Needle 0.5 µl 26 (0.47) 0.5BR-S-0.47C * 0.5 µl 23 (0.63) 0.5BR-S-0.63C * 10 µl 26 (0.47) 10R-S-0.47C µl 23 (0.63) 10R-S-0.63C µl Gas Tight 23 (0.63) 10R-S-GT-0.63C *Denotes spare Needle and Plunger kit. Septa Choose from a number of different septa types: Enduro Blue = For non-demanding routine applications. EC = Combines significantly longer injection life, low bleed and low injection port adhesion. HT = Bleed and temperature optimized, combined with outstanding mechanical properties. Type Material Durability Resealing Solvent Resistance Enduro Blue Tear Resistance Maximum Temperature High Temperature Silicone Excellent Excellent Excellent Excellent 350 C EC High Temperature Silicone Excellent Excellent Excellent Excellent 400 C HT BTO Silicone Excellent Excellent Excellent Excellent 400 C Type Shimadzu 9A, 14, 15A, 16, 17A, 2010 & 2014 Enduro Blue EC HT

16 Shimadzu GC Supplies - Instrument Quick Pick Guide Inlet Liners Description and Geometry OD ID Length For GC-2010 (SPL-2010 Injector), GC-2014 (SPL-2014 Injector) and GC-17A (SPL-17 Injector) Split / Splitless FocusLiner * Split / Splitless Taper FocusLiner * Split / Splitless FocusLiner Split / Splitless Taper FocusLiner ConnecTite Liner Standard ConnecTite Liner Top Hole ConnecTite Liner Bottom Hole Split, straight-through liner Splitless straight-through liner Split / Splitless with Single Taper Split / Splitless with middle gooseneck Split / Splitless with recessed gooseneck and quartz wool Split / Splitless with middle gooseneck ConnecTite (0.53 mm ID columns) SPME Liner For GC-14(SPL-14 Injector) Split / Splitless FocusLiner Split / Splitless Taper FocusLiner Split / Splitless with 2.0 mm middle gooseneck Split / Splitless with single taper Taper / Gooseneck FocusLiner Taper FocusLiner ConnecTite Straight Double Taper PTV/LVI Splitless, Direct, wide bore liner for Shimadzu 9A/16A GC * When using a standard 42 mm needle for autosamplers, the sample will be injected on top of the wool for this liner. O-rings and Sealing Rings Description Usage Viton O-ring 16 Temperatures up to 300 C. For 2010 & 2014 (SPL-2010 Injector & SPL-2014 Injector) Graphite Sealing Ring Temperatures up to 450 C. For 14, 15A & 16 (SPL-14 injector) Graphite Sealing Ring Temperatures up to 450 C. For 17A (SPL-17 injector)

17 SilTite FingerTite Ferrules Description Column ID Ferrule ID SilTite FingerTite Shimadzu 2010 INJ / FID Starter Kit mm 0.4 mm * SilTite FingerTite Shimadzu 2010 INJ / MS Starter Kit mm 0.4 mm * SilTite FingerTite Shimadzu 2010 INJ / FID Starter Kit 0.53 mm 0.7 mm * SilTite FingerTite Shimadzu 2010 Injector Starter Kit 0.53 mm 0.7 mm * SilTite FingerTite Shimadzu 17A INJ / FID Starter Kit 0.53 mm 0.7 mm * SilTite FingerTite Shimadzu 17A Injector Starter Kit 0.53 mm 0.7 mm * Replacement Parts SilTite FingerTite Ferrule 0.4 mm mm 0.4 mm SilTite FingerTite Ferrule 0.5 mm 0.32 mm 0.5 mm SilTite FingerTite Ferrule 0.7 mm 0.53 mm 0.7 mm SilTite FingerTite Ferrule Blanking SilTite FingerTite Female Nut * Each starter kit includes all the parts necessary to convert one GC system (one injector and one detector) to the SilTite FingerTite system. In addition there are five SilTite FingerTite nuts, ten SilTite FingerTite ferrules, and a ferrule install tool which allows you to seat the ferrule in the correct position on the capillary column. Ferrules Column ID Description GC14A, GC17A, GC2010 and GC2014 Detector / Injectors (Not for MS interfaces or QP2010 Injector) mm ID columns 100% Graphite mm ID columns 100% Graphite mm OD packed columns 100% Graphite mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules n/a SilTite Metal Nuts - Slotted QP5000/5050 Standard MS Interface QP5000-I mm ID columns 15% Graphite/ 85% Vespel Ferrules QP5000-I 0.32 mm ID columns 15% Graphite/ 85% Vespel Ferrules QP5000-II & QP mm ID columns 15% Graphite/ 85% Vespel Ferrules QP5000-II & QP mm ID columns 15% Graphite/ 85% Vespel Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Ferrules n/a SilTite Metal Nuts-QP5000/5050 Standard MS interface QP5000/5050 Wide Bore MS Interface, QP2010 Injector and QP2010 Standard MS Interface mm ID columns 15% Graphite/ 85% Vespel Ferrules mm ID columns 15% Graphite/ 85% Vespel Ferrules mm ID columns 15% Graphite/ 85% Vespel Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules n/a SilTite Metal Nuts Replacement SilTite Nuts 2010 GC-MS System GC-MS System with QP5000 series MS /2014 GC Injectors and atmospheric detectors QP5000 Jet Separator MS Interface QP5000 Direct MS Interface All Injectors Jet Separator (Starter Kit), except 2010/ * Includes ten ferrules, two SilTite nuts. 17

18 Thermo Scientific GC Supplies - Instrument Quick Pick Guide Autosampler Syringes Thermo Scientific / CE Instruments / Fisons All needles have a cone tip style. Autosampler Syringe Specifications TriPlus AS3000 AS2000 AS200/ Volume Length Gauge Syringe Code 800 (OD mm) Septa Plunger Stop Syringe Needle Fixed Needle 10 µl (0.63) 10F-C/T-GT-5/0.63C ü µl (0.63) 10F-BT-GT-5/0.63C µl (0.63) 10F-BT-8/0.63C µl (0.47) 10F-C/T-8/0.47C ü µl (0.47) 10F-BT-8/0.47C µl (0.63) 10F-C/T-5/0.63C ü µl (0.63) 10F-VA8400/BT-5/0.63C µl (0.47) 10F-C/T-5/0.47C ü µl (0.47) 10F-BT-5/0.47C Removable Needle 10 µl (0.47) 10R-C/T-5/0.47C ü µl (0.47) 10R-BT-GT-0.47C µl (0.63) 10R-C/T-5/0.63C ü µl (0.63) 10R-BT-0.63C µl (0.47) 10R-C/T-8/0.47C ü µl (0.47) 10R-BT-8/0.47C Choose from a number of different septa types: GP = For non-demanding routine applications. EC = Combines significantly longer injection life, low bleed and low injection port adhesion. MN = Premium septa for autosamplers, up to 400 injections per septum. HT = Bleed and temperature optimized, combined with outstanding mechanical properties. Type Material Durability Resealing Solvent Resistance Tear Resistance Maximum Temperature GP Silicone Good Good Excellent Good 200 C EC High Temperature Silicone Excellent Excellent Excellent Excellent 400 C MN High Temperature Silicone Excellent Excellent Excellent Excellent 400 C HT BTO Silicone Excellent Excellent Excellent Excellent 400 C Diameter Type For TRACE GP EC MN HT For TRACE 1300 and Focus 17* EC * MN * HT * Maximum temperature for the Thermo septa diameter 17 mm is 330 C. Inlet Liners Description and Geometry For TRACE and Focus OD ID Length Splitless FocusLiner (for use with 70 mm Needle) Splitless FocusLiner with Top-end Restriction (for use with 70 mm Needle)

19 Inlet Liners Continued Description and Geometry OD ID Length Split FocusLiner (for use with 50 mm Needle) Splitless FocusLiner (for use with 50 mm Needle) Splitless with Single Taper Splitless with Single Taper Splitless, Straight-through Liner SPME Liner Split, Straight-through Liner TRACE 2000 PTV Liner Sintered Glass, Large Volume Injection (LVI) Liner ConnecTite Liner Standard ConnecTite Liner Top Hole ConnecTite Liner Bottom Hole For TRACE 1300 Split / Splitless FocusLiner Split / Splitless Taper FocusLiner Split / Splitless FAST FocusLiner Split / Splitless Tapered FAST FocusLiner ConnecTite Liner Standard ConnecTite Liner Top Hole ConnecTite Liner Bottom Hole Split, Straight-through Liner Split, with Quartz Wool Split / Splitless with Single Taper Split / Splitless with Single Taper (Quartz Wool) Split / Splitless with Double Taper Direct, Straight-through Liner Split / Splitless Quartz, Straight-through Liner / Taper / Gooseneck FocusLiner Taper FocusLiner ConnecTite Straight Double Taper PTV/LVI Splitless with Recessed Gooseneck Split / Splitless Recessed Gooseneck (Quartz Wool)

20 Thermo Scientific GC Supplies - Instrument Quick Pick Guide O-rings and Sealing Rings Description Usage For 8000 & TRACE GCs Graphite Sealing Ring For TRACE 1300 Viton O-Ring 8 mm ID. Temperatures up to 450 C. Suitable for use with liners and Temperatures up to 300 C. Suitable for liners with OD of 6.3 mm Graphite Sealing Ring Temperatures up to 450 C. Suitable for all inlet liners above except and Graphite Sealing Ring Temperatures up to 450 C. Suitable for use with liners and SilTite FingerTite Ferrules Description Column ID Ferrule ID SilTite FingerTite Thermo Injector/FID Starter Kit mm 0.4 mm * SilTite FingerTite Thermo Injector/GC-MS ISQ Starter Kit mm 0.4 mm * SilTite FingerTite Thermo Injector/GC-MS Starter Kit mm 0.4 mm * SilTite FingerTite Thermo Injector/FID Starter Kit 0.53 mm 0.7 mm * SilTite FingerTite Thermo Injector Starter Kit 0.53 mm 0.7 mm * For TRACE 1300 SilTite FingerTite INJ / FID Starter Kit mm 0.4 mm * SilTite FingerTite Capillary / FID Starter Kit mm 0.4 mm * SilTite FingerTite INJ / MS Starter Kit mm 0.4 mm * Replacement Parts SilTite FingerTite Ferrule 0.4 mm mm 0.4 mm SilTite FingerTite Ferrule 0.5 mm 0.32 mm 0.5 mm SilTite FingerTite Ferrule 0.7 mm 0.53 mm 0.7 mm SilTite FingerTite Ferrule Blanking SilTite FingerTite Female Nut SilTite FingerTite INJ Base Seal mm SilTite FingerTite MS Adaptor SilTite FingerTite Injector mm * Each starter kit includes all the parts necessary to convert one GC system (one injector and one detector) to the SilTite FingerTite system. In addition there are five SilTite FingerTite nuts, ten SilTite FingerTite ferrules, and a ferrule install tool which allows you to seat the ferrule in the correct position on the capillary column. Ferrules Description Column ID Ferrule ID SilTite Metal Ferrules mm 0.4 mm 10* For GC-MS Interface Connections (Starter Kit) 0.32 mm 0.5 mm 10* mm 0.8 mm 10* mm 0.4 mm 10 # For TRACE 1300 Split / Splitless Injectors (Starter Kit) 0.32 mm 0.5 mm 10 # mm 0.8 mm 10 # /32" 0.81 mm 10 #

21 Ferrules Continued Description Column ID Ferrule ID 15% Graphite / 85% Vespel Ferrules mm 0.4 mm mm 0.5 mm For All Injectors & Detectors (Not 0.53 mm 0.8 mm for 8000 Series, Focus, TRACE/ 1/8" OD ed Ultra GC) Columns 1/8" /4" OD ed Columns 1/4" For All Focus, Trace/Ultra mm 0.4 mm 10# Injectors & Detectors at atmospheric pressure e.g. FID 0.32 mm 0.5 mm 10# (Not for GC-MS) 0.53 mm 0.8 mm 10# Brass Nut for Focus, Trace/ Ultra GC Injectors & Non-MS Detectors mm 0.4 mm mm 0.5 mm For TRACE 1300 Injectors & Detectors at atmospheric pressure e.g. FID For TRACE 1300 GC-MS Interface Connection 100% Graphite Ferrules For Injectors & Detectors at atmospheric pressure e.g. FID (Not for GC-MS) For TRACE 1300 Injectors & Detectors at atmospheric pressure e.g. FID (Not for GC-MS) 0.53 mm 0.8 mm for 1/8" OD ed Columns 1/8" for 1/4" OD ed Columns 1/4" mm 0.4 mm mm 0.5 mm mm 0.8 mm mm 0.5 mm mm 0.8 mm /8" OD ed Columns 1/8" /4" OD ed Columns 1/4" mm 0.5 mm mm 0.8 mm for 1/8" OD ed Columns 1/8" for 1/4" OD ed Columns 1/4" Replacement SilTite Metal Ferrules mm 0.4 mm For All GC-MS Interface 0.32 mm 0.5 mm Connections 0.53 mm 0.8 mm /32" 0.81 mm mm 0.4 mm For TRACE 1300 Connections 0.32 mm 0.5 mm mm 0.8 mm /32" 0.81 mm Replacement SilTite Nuts SilTite Metal Nuts For TRACE 1300 GC-MS Interface Connection For TRACE 1300 Split / Splitless Injector Replacement SilTite Base Seals For TRACE 1300 Split / Splitless Injector * Includes 10 ferrules, 2 SilTite nuts. # To be used in combination with brass nut ( ) 21

22 Expert Tips GC Supplies - Instrument Quick Pick Guide Problem Resolution No Column Flow Check carrier gas flow and adjust. Replace septum/injector seal with EC septum. Visually check column integrity i.e. is it broken? Remove section if small enough or replace column. High Column Bleed Retention Time Shifts Poor Resolution or Loss of Resolution Phase Breakdown Poor or No Detector Response For All Peaks Check published maximum temperature. Check carrier flow rates / velocity, correct for column/length adjust if necessary. Check column has not moved in detector. Check for leaks produced during initial heating. Check oxygen filter is not spent replace if necessary. Make sure detector temperature is higher than final column temperature if possible. Check cleanliness of detector clean if necessary. Recondition column re-run conditioning program. Cut 50 cm from the front end of the column. Check temperature program. Check injector temperature. Ensure manual injection technique is consistent. Check carrier gas flow rate / velocity. Check for injector leaks. Ensure same solvent being used. Column is contaminated - rinse or replace. Remove 50 cm from front of column. Phase breakdown replace column. Use correct column or phase. Use different temperature program. Check injector temperature is it correct for solvent and analytes. Check injection technique. Check carrier flow / velocity. Sample overload - dilute or change split ratio. Contaminated column rinse or replace. Phase breakdown replace column. Check for leaks and repair. Check oxygen traps and replace if necessary. Exceeded upper temperature limit of column for extended periods replace column. Column contamination replace column (perform extra clean up of samples). Damage due to sample do not inject strong acid or base samples. Correct injection technique for concentration of analyte. Check proper liner is used for injection technique. Check syringe needle not blocked or plunger is not leaking. Check split ratio if using split technique. Check injector temperature is correct. Check detector temperature is correct. Check flow rates of detector gas(es). Error in sample concentration verify concentrations. Detector Problems PID - Dirty window clean according to manufacturer s specifications. ELCD - Faulty reactor tube. - Contaminated alcohol. - Incorrect alcohol flow rate. ECD - Impurities in nitrogen. - Dirty detector; clean (bake) according to manufacturer s specifications. NPD - Bad bead. FID - Partially blocked jet. FPD - Incorrect gas flow rates. - Incorrect filter installed. - Clean filter. TCD - Balance flow rates. 22

23 Poor Peak Shape Problem Reason Resolution Peak Fronting Column overload. Reduce sample concentration or injection volume. Incorrect polarity of column for compound. Use correct column. Peak Tailing Column is active. Remove first meter of column; recheck; replace column if necessary. Split Peaks Active inlet liner. Incorrect column for analysis. Incorrect column installation. Poor injection technique. Mixed solvents. Replace liner with clean, deactivated liner. Use correct column. Check inlet and outlet connections, and for any cold spots. Refine injection technique. Use only single solvent system. Poor resolution. Use different column or change temperature profile. Ghost Peaks Run GC without injection; if ghost peaks disappear then the problem is probably the syringe or solvent; if ghost peaks are still evident then the problem is either the septum or the breakdown of the phase. Contaminated syringe or solvents. Clean syringe thoroughly and replace solvents. Septum bleed. Replace with new EC septum. Specific Peaks Low Response Breakdown of column phase. Too large an injection volume. Column is active. Active inlet liner. Incorrect calculation of sample. FID altered gas flows. Choose different phase which restricts breakdown. Decrease injection volume. Remove first meter of column; recheck; replace column if necessary. Replace liner with clean, deactivated liner. Verify calculations. Readjust gas flows. 23

24 GC Supplies - Instrument Quick Pick Guide Choose for Your Instrument SGE Analytical Science (SGE) is a world renowned brand for components and consumables used in scientific analysis. Primarily in the field of scientific glass engineering for liquid handling and separation science, since its beginnings in 1960, SGE has become the global market leader in niche areas such as autosampler syringes and GC inlet liners. Completing the transition into Trajan after acquisition in 2013, SGE products make up a solid foundation of Trajan s portfolio and will continue to be created and supported by Trajan customer service and distribution networks worldwide. For more information, visit vwr.com or contact your VWR representative. Approved Distribution Partner BR-0479-G Trajan Scientific and Medical 09/ M Lit. No

Choose for Your Instrument. GC Supplies - Bruker (Varian) Instrument Quick Pick Guide

Choose for Your Instrument. GC Supplies - Bruker (Varian) Instrument Quick Pick Guide Choose for Your Instrument GC Supplies - Bruker (Varian) Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Your chromatography analysis

More information

Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide

Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide Choose for Your Instrument GC Supplies - Agilent Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Your chromatography analysis does

More information

AZ Chrom s.r.o.

AZ Chrom s.r.o. AZ Chrom s.r.o. azetchrom@hplc.sk www.azetchrom.sk ÙÝ Í ó Ê ²ñÞ «µ» ² «³»² Ï«½µ Ð ½µ Ù«¼» Í ²¹ ²¹» Í» ²» Ô ²» Ñó ²¹ Ú» Ú ²¹» Ì» Ú» Ako nás možno kontaktova : AZ Chrom s.r.o. Robotnícka 10 831 03 Bratislava

More information

GC Supplies - Varian/Bruker Instrument Quick Pick Guide

GC Supplies - Varian/Bruker Instrument Quick Pick Guide GC Supplies - Varian/Bruker Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings Ferrules SilTite TM FingerTite Ferrules Electron Multipliers Instrument Quick Pick for Varian / Bruker Autosampler

More information

Sample preparation Methods Analysis. Biodiesel Analysis guide.

Sample preparation Methods Analysis. Biodiesel Analysis guide. Sample preparation Methods Analysis Biodiesel Analysis guide www.trajanscimed.com Biodiesel is taking its place as one of the new cleaner and greener solutions required to meet the world s growing energy

More information

Biodiesel Analysis Toolkit

Biodiesel Analysis Toolkit Biodiesel Analysis Toolkit Sample Preparation, Methods and Analysis www.sge.com Introduction Biodiesel is taking its place as one of the new cleaner and greener solutions required to meet the world s growing

More information

Selecting The Appropriate INLET LINER

Selecting The Appropriate INLET LINER Selecting The Appropriate INLET LINER Don t Let The Quality of Your Inlet Liner Limit the Efficiency of Your GC System. ANALYTE ANALYTE CONCENTRATION THERMALLY LABILE HIGH Liners for SPME SPME LOW (TRACE)

More information

CrossLab. Supplies for PerkinElmer GC Systems. to work for you non-agilent GCs. Put Agilent innovation and quality. Agilent. Quick Reference Guide

CrossLab. Supplies for PerkinElmer GC Systems. to work for you non-agilent GCs. Put Agilent innovation and quality. Agilent. Quick Reference Guide works with BRUKER PERKINELMER SHIMADZU THERMO SCIENTIFIC AND MORE Put innovation and quality to work for you non- GCs is a growing portfolio of supplies critical to instrument performance and productivity.

More information

AZ Chrom s.r.o.

AZ Chrom s.r.o. AZ Chrom s.r.o. azetchrom@hplc.sk www.azetchrom.sk Í Ì» Ú ²¹» Ì» ÙÝ Ú» æ Ì» ͳ ß» ² ª» ÛßÍÇ ÎÛÔ ßÞÔÛ ÔÛßÕ ÚÎÛÛ ÒÑ ÌÑÑÔÍ ÎÛÏË ÎÛÜ Í Ì» Ú ²¹» Ì»» ²» ¹»²» ±² º» »³ º± ¹ ½ ±³ ±¹»³ ¼» ª» ²¹ ²» ô» µ º»» ² ±²

More information

CrossLab. Supplies for Thermo Scientific GC Systems. work for you non-agilent GCs. Put Agilent innovation and quality to. Agilent

CrossLab. Supplies for Thermo Scientific GC Systems. work for you non-agilent GCs. Put Agilent innovation and quality to. Agilent works with BRUKER PERKINELMER SHIMADZU THERMO SCIENTIFIC AND MORE Put innovation and quality to work for you non- GCs is a growing portfolio of supplies critical to instrument performance and productivity.

More information

Best Selling 30 % OFF* GC Accessories. Expires: September 27, 2013

Best Selling 30 % OFF* GC Accessories. Expires: September 27, 2013 Best Selling GC Accessories Liners Ferrules Cool-Lock Nut Septa Syringes Gold Seals 30 % OFF* Expires: September 27, 2013 Mention Offer Code: GACC0913 Any GC Accessories in this brochure First time purchasers

More information

GC Accessories. Solutions Guide. Liners Ferrules Cool-Lock Nut. Septa Vials Gold Seals

GC Accessories. Solutions Guide. Liners Ferrules Cool-Lock Nut. Septa Vials Gold Seals GC Accessories Solutions Guide Liners Ferrules Cool-Lock Nut Septa Vials Gold Seals Table of Contents Inlet Base Seals... 3 Installation Nuts... 4-5 Mini-Unions... 5 Septa... 6-7 Ferrules... 8-9 Injection

More information

Microsep Low-Bleed PTFE-Lined Septa. XLB Septa

Microsep Low-Bleed PTFE-Lined Septa. XLB Septa Septa Chromatogram Cross Reference Guide Actual Size Drawing Measurement 1/4" (6mm) Shimadzu*, SRI* Chromatographs 3/8" (9.5mm) 7/16" (11mm) Antek, Finnigan 9100, 9600, Gow- Mac, Agilent 5700, 5880 & 5900,

More information

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation Liner Selection in GC Jaap de Zeeuw Restek Middelburg, The Netherlands What is a liner? A liner is an inert glass tube that is positioned inside the injection port of the GC The sample solution is introduced

More information

GC Injector Liners. Bruker Varian Agilent (HP) Perkin Elmer Finnigan. Phone: Page 4

GC Injector Liners. Bruker Varian Agilent (HP) Perkin Elmer Finnigan.   Phone: Page 4 Bruker Varian Agilent (HP) Perkin Elmer Finnigan www.excelcomponent.com sales@excelcomponent.com Phone: 909-229-6363 Page 4 Deactivated Split/Splitless Injector We offer a full line of Split/Splitless

More information

6890 Installing ¼ Glass Columns

6890 Installing ¼ Glass Columns 6890 Installing ¼ Glass Columns A15891 This document is believed to be accurate and up-to-date. However, Agilent Technologies, Inc. cannot assume responsibility for the use of this material. The information

More information

Copyright 2004 Alltech Associates, Inc.UNP. brochure #487K. accessories

Copyright 2004 Alltech Associates, Inc.UNP. brochure #487K. accessories Copyright 2004 Alltech Associates, Inc.UNP brochure #487K accessories GC Organizers 5-Column Storage Unit Plastic Storage Box 10-Column Storage Unit Utility Cabinet Lab Storage Bin Unit GC Organizers

More information

GCMS-QP2010 Series. Consumables. Shimadzu Gas Chromatograph/Mass Spectrometer

GCMS-QP2010 Series. Consumables. Shimadzu Gas Chromatograph/Mass Spectrometer GCMS-QP2010 Series Consumables Shimadzu Gas Chromatograph/Mass Spectrometer Diag. # 1) Injection Port - Septum Nut 2) Injection Port - Needle Guide 3) Septum 4) O-ring for Glass Insert 5) Glass Insert

More information

Agilent 6890 Gas Chromatograph

Agilent 6890 Gas Chromatograph Agilent 6890 Gas Chromatograph Maintaining Your GC Agilent Technologies Notices Agilent Technologies, Inc. 2007 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Spare Parts Catalog. PN , Revision October 2011

Thermo Scientific. TRACE GC Ultra. Gas Chromatograph Spare Parts Catalog. PN , Revision October 2011 Thermo Scientific TRACE GC Ultra Gas Chromatograph Spare Parts Catalog PN 31709210, Revision October 2011 TRACE GC Ultra Spare Parts Catalog October 2011 Edition Part Number 317 092 10 2007-2011 Thermo

More information

GC Inlet Maintenance:

GC Inlet Maintenance: Restek GC Accessories GC Inlet Maintenance: Restek s Quick-Reference Guide Help ensure quality data by selecting the right GC inlet supplies. Prevent unwanted downtime with a preventative GC inlet maintenance

More information

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application 7890A/7890B GC Overview October 29, 2014 1 Definitions Carrier Gas Pressurized gas used to transport the sample through the system.

More information

Chromatography. Research Supplies. 2014/2015 Catalog

Chromatography. Research Supplies. 2014/2015 Catalog Chromatography Research Supplies 2014/2015 Catalog The CRS Commitment Service That Rev lves Around You! Our purpose at CRS is to meet our customer s requirements for quality, service, and value. Quality

More information

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS FLASH VAPORISATION INJECTION Split Splitless On-Column COOL INJECTION Large Volume Injection (LVI) On-Column On-Column-SVE (with solvent vapour

More information

Practical Steps in GC Troubleshooting

Practical Steps in GC Troubleshooting Practical Steps in GC Troubleshooting Techniques, Tips, and Tricks Mark Sinnott Application Engineer GC Columns & Supplies Page 1 Everything was just fine and then this happened! How do I go about TROUBLESHOOTING?

More information

Agilent GCs. Genuine Restek Replacement Parts. More Parts & Accessories for More GC Systems. Innovative Chromatography Products

Agilent GCs. Genuine Restek Replacement Parts. More Parts & Accessories for More GC Systems. Innovative Chromatography Products Genuine Restek Replacement Parts Agilent GCs More Parts & Accessories for More GC Systems Agilent Bruker/Varian PerkinElmer Shimadzu Thermo Scientific And More! Innovative Chromatography Products www.restek.com

More information

Method Development for Capillary GC Systems. Slide 1

Method Development for Capillary GC Systems. Slide 1 Method Development for Capillary GC Systems Slide 1 AREAS TO OPTIMIZE Injector Carrier gas Column temperature Slide 2 COMMON INJECTOR MODES Vaporization Injection Modes Megabore Direct Split Splitless

More information

Genuine Restek Replacement Parts For Agilent 5890 GCs

Genuine Restek Replacement Parts For Agilent 5890 GCs Genuine Restek Replacement Parts For Agilent 5890 GCs Don't Let it Go to Waste. Chromatography Products 2 The Answer to Turning Your Trash to Treasure! Dear Colleague, Just when you thought you may be

More information

1310 Inlets. 1 of 36. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

1310 Inlets. 1 of 36. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual 30 Inlets This section contains illustrated parts breakdowns for 6890 GC inlets and related components. Split/Splitless Inlet Split/Splitless Inlet Column Liners Split/Splitless Inlet EPC Pneumatic Module

More information

CP-3800 GAS CHROMATOGRAPH

CP-3800 GAS CHROMATOGRAPH CP-3800 GAS CHROMATOGRAPH P/N 03-914689-00 Rev 4 TABLE OF CONTENTS I. GC OPERATION... 2 Overview... 2 Instrument Setup... 3 Building a Method... 4 Automation... 5 Activating the GC Method... 5 Making a

More information

GC Inlets. An Overview. Simon Jones GC Applications Engineer

GC Inlets. An Overview. Simon Jones GC Applications Engineer GC Inlets An Overview Simon Jones GC Applications Engineer Types of Inlets Purged Packed Split / Splitless Cool On Column Programmable Temperature Vaporization Volatiles Interface Multi Mode Inlet Where

More information

The next level of True Blue Performance

The next level of True Blue Performance Restek Supplies & Accessories The next level of True Blue Performance Topaz GC inlet liners feature revolutionary technology and inertness to deliver the next level of: Deactivation Reproducibility Productivity

More information

High-Performing Restek PAL SPME Fibers

High-Performing Restek PAL SPME Fibers Restek Sample Handling High-Performing Restek PAL SPME Fibers Suitable for a wide range of analyte chemistries and sample matrices. Reliable performance meets or exceeds other brands. Robust aluminum hub

More information

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Brian Fitz and Bill Wilson Agilent Technologies, Inc. 285 Centerville Road Wilmington,

More information

Introducing Restek s most inert liner The Sky Inlet Liner! Chromatography Products.

Introducing Restek s most inert liner The Sky Inlet Liner! Chromatography Products. Introducing Restek s most inert liner The Sky Inlet Liner! Chromatography Products www.restek.com TM Inspiring Great Patent pending True Blue Performance Increase accuracy and reproducibility with state-of-the-art

More information

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X

GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X GC Best Practices & Troubleshooting Group/Presentation Title Agilent Restricted Month ##, 200X Troubleshooting Tips 1. Isolate the problem. (Blank Runs, Inject Un-retained Compound, Know what it is not)

More information

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard Agilent Preventive Maintenance provides factory recommended service for your analytical systems to assure reliable operation and the accuracy of your results. Delivered by highly-trained and certified

More information

Setting up SilFlow for BackFlush in your GC

Setting up SilFlow for BackFlush in your GC Setting up SilFlow for BackFlush in your GC What is backflush and why use it? The BackFlush system eliminates the need to bake heavy sample fractions off the capillary column. Oils, tars and other semivolatile

More information

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy The world leader in serving science Ultra Fast GC Determination of Total Hydrocarbons (C7-C40) and BTEX in Water and Soils through Direct Resistively Heated capillary columns and Robotic Autosampler. Fausto

More information

Shimadzu GCs. Genuine Restek Replacement Parts

Shimadzu GCs. Genuine Restek Replacement Parts Genuine Restek Replacement Parts Shimadzu GCs More Parts & Accessories for More GC Systems Agilent Bruker/Varian PerkinElmer Shimadzu Thermo Scientific And More! Innovative Chromatography Products www.restek.com

More information

Analysis of Petroleum Fractions by ASTM D2887

Analysis of Petroleum Fractions by ASTM D2887 Analysis of Petroleum Fractions by ASTM D2887 Peter Morgan, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 2582 Key Words Simulated distillation, D2887, TRACE TR-SimDist Abstract ASTM

More information

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Application Note Energy and Chemicals Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel Applying the Energy Institute Method IP 8 with an Agilent J&W

More information

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Application Note Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593 Authors Kelly Beard and James McCurry Agilent Technologies, Inc. Abstract An Agilent

More information

trace samples >2µL 4.0mm 6.5mm x 78.5mm accommodates more polar solvents and lower MW solvents 5.0mm 6.5mm x 78.5mm 2.0mm 6.5mm x 78.

trace samples >2µL 4.0mm 6.5mm x 78.5mm accommodates more polar solvents and lower MW solvents 5.0mm 6.5mm x 78.5mm 2.0mm 6.5mm x 78. Supplies : Liners C O L U M N I N S T A L L S T H I S E N D 2mm Splitless 4mm Splitless 4mm Splitless w/wool 5mm Splitless 2mm Splitless (Quartz) 4mm Splitless (Quartz) Splitless Liners 4mm Splitless w/wool

More information

GC AND GC/MS. Your Essential Resource for Columns & Supplies

GC AND GC/MS. Your Essential Resource for Columns & Supplies GC AND GC/MS Your Essential Resource for Columns & Supplies GC AND GC/MS Achieve excellent, reproducible performance for difficult samples For over 40 years, Agilent has broken new ground with innovations

More information

Set Your Sights on Superior Performance

Set Your Sights on Superior Performance Restek Sample Handling Set Your Sights on Superior Performance Rugged stainless steel construction ensures longer lifetimes. Faster extraction means higher sample throughput. Better sensitivity allows

More information

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals Phenomenex Exclusive! Easy Seals Inlet Base Seals Guaranteed fit for Agilent 5000, 6000 and 7000 Series GCs The Easy Seals Gold Standard No Strained Hands No Troublesome Washers or Adaptors Continuing

More information

Using the PSD for Backflushing on the Agilent 8890 GC System

Using the PSD for Backflushing on the Agilent 8890 GC System Application Note Petrochemicals Using the PSD for Backflushing on the Agilent 889 GC System Author Brian Fitz Agilent Technologies, Inc. Wilmington, DE, USA. Abstract An Agilent 889 series GC equipped

More information

Agilent 7820A Gas Chromatograph

Agilent 7820A Gas Chromatograph Agilent 7820A Gas Chromatograph Illustrated Parts Breakdown 15 Illustrated Parts Breakdown Overview of the IPB 297 Inlets 298 Detectors 316 EPC modules 357 Nickel catalyst accessory 365 Covers 369 Automatic

More information

Agilent Multimode Inlet for Gas Chromatography

Agilent Multimode Inlet for Gas Chromatography Agilent Multimode Inlet for Gas Chromatography Technical Note Agilent Multimode Inlet for the 7890A GC Designed to give you ease of use and maximum flexibility, the Agilent Multimode Inlet does everything

More information

Set Your Sights on Superior Performance

Set Your Sights on Superior Performance Restek Sample Handling Set Your Sights on Superior Performance Restek PAL SPME Arrow Rugged stainless steel construction ensures longer lifetimes. Faster extraction means higher sample throughput. Better

More information

Technical Procedure for Gas Chromatography (GC-FID)

Technical Procedure for Gas Chromatography (GC-FID) Technical Procedure for Gas Chromatography (GC-FID) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph (GC- FID). 2.0 Scope This procedure applies to all

More information

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI) Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI) Application Note All Industries Authors Bill Wilson and Chin-Kai Meng Agilent Technologies, Inc. 2850 Centerville Road Wilmington,

More information

SGE. Hamilton. Precision. Norm-Ject. NewERA SYRINGE PUMPS. Sampling glass microliter. Plastic Syringes. Stainless Steel. glass microliter.

SGE. Hamilton. Precision. Norm-Ject. NewERA SYRINGE PUMPS. Sampling glass microliter. Plastic Syringes. Stainless Steel. glass microliter. glass microliter Hamilton and SGE Norm-Ject Plastic Syringes Precision Sampling glass microliter Mininert Valves NewERA SYRINGE PUMPS & Stainless Steel SYRINGES SYRINGES Syringe Basics..........................................369

More information

Techniques for Improving the Reproducibility of GC Analysis

Techniques for Improving the Reproducibility of GC Analysis Techniques for Improving the Reproducibility of GC Analysis Primary Areas of Concern Sample Auto-Injector Inlet Column Detector Sample Extract Handling and Care It is critical that the sample extract be

More information

PORTAFOLIO DE CROMATOGRAFÍA LABINS

PORTAFOLIO DE CROMATOGRAFÍA LABINS PORTAFOLIO DE CROMATOGRAFÍA LABINS LABINS SAS NIT 900090654 6 Tel 57 1 4725717 Cel 57 3156342765 labins sas@outlook.com gerencia@labins.com.co www.labins.com.co Catálogos: Agilent Technologies, SGE, Separation

More information

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D759 Application Petrochemical Author James D. McCurry Agilent Technologies 285 Centerville

More information

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS) Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the pyrolysis-gas chromatograph-mass spectrometer

More information

MET-Biodiesel Capillary GC Columns

MET-Biodiesel Capillary GC Columns MET-Biodiesel Capillary GC Columns Product Specifications Product Features & Benefits Chromatograms FAQs Related Products Updated: February 2, 2009 Product Specifications 2 Product Specifications What

More information

Swagelok.

Swagelok. www.ovsc.com Swagelok Nuts Front Ferrules Back Ferrules Unions Swagelok Size Brass Stainless Steel Teflon Fittings (Inches) Qty/Pkg Qty/Pkg Qty/Pkg 1/16" B-102-1 Each SS-102-1 Each 1/8" B-202-1 10 Each

More information

CHROMATOGRAPHY TIME IN CONVENTIONAL GAS THE FASTEST INJECTION-TO-INJECTION CLARUS 680 GAS CHROMATOGRAPH NEW

CHROMATOGRAPHY TIME IN CONVENTIONAL GAS THE FASTEST INJECTION-TO-INJECTION CLARUS 680 GAS CHROMATOGRAPH NEW CLARUS 680 GAS CHROMATOGRAPH THE FASTEST INJECTION-TO-INJECTION TIME IN CONVENTIONAL GAS CHROMATOGRAPHY NEW Every fast-paced, high-volume laboratory shares a common goal: to speed up analytical cycle times.

More information

For more information about Agilent Technologies services please visit our web site using the following URL

For more information about Agilent Technologies services please visit our web site using the following URL Agilent Preventive Maintenance provides factory recommended service for your analytical systems to assure reliable operation and the accuracy of your results. Delivered by highly-trained and certified

More information

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust Mark Sinnott Application Engineer Columns and Consumables June 20, 2008 Primary Areas of Concern Sample Auto-Injector Inlet

More information

Hot Injection Adapter Kit - Installation Guide

Hot Injection Adapter Kit - Installation Guide Hot Injection Adapter Kit - Installation Guide This guide provides the instruction for installing the Hot Injection Adapter kit (P/N 19050733) on the SSL/SSLBKF injector for the use with an external device

More information

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter Cd The Chrom Doctor Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter Jaap de Zeeuw, Restek Corporation, Middelburg, The Netherlands. In Part 1 of this series we focused

More information

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS) Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS) 1.0 Purpose This technical procedure shall be followed for the operation of the gas chromatograph-mass spectrometer (GC-MS). 2.0 Scope

More information

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns Compatible with hydrogen, for 50% faster run times. Improved resolution between oxygenates and hydrocarbons, for more accurate reporting. Individually

More information

Thermo Scientific GCs

Thermo Scientific GCs Genuine Restek Replacement Parts Thermo Scientific GCs More Parts & Accessories for More GC Systems Agilent Bruker/Varian PerkinElmer Shimadzu Thermo Scientific And More! Innovative Chromatography Products

More information

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust Mark Sinnott Application Engineer Columns and Consumables June 20, 2008 Primary Areas of Concern Sample Auto-Injector Inlet

More information

GC Columns and Accessories >> GC Instrument Spare Parts

GC Columns and Accessories >> GC Instrument Spare Parts Thermal Conductivity Detector (TCD), TRACE GC Ultra and FOCUS GC Item 1 Adapter for capillary column (Kit) 34709542 1 2 Retaining nut for 6mm OD metal column and ferrule 35020117 1 3 Brass front/back ferrule

More information

Proof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut

Proof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut Proof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut Application Note Environmental Author Ken Lynam Agilent Technologies, Inc. Abstract Specially designed self-tightening

More information

Agilent Multimode Inlet

Agilent Multimode Inlet Agilent Multimode Inlet Large Volume Injection Tutorial Agilent Technologies Notices Agilent Technologies, Inc. 2009 No part of this manual may be reproduced in any form or by any means (including electronic

More information

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271 Restek Replacement Parts for Agilent HPLC Systems Meet or exceed OEM performance. Agilent part # qty. cat.# price Preventive Maintenance Kit Includes: rotor seal, needle seat, needle assembly, seat cap

More information

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis Page 1 Alternate Carrier Gas Considerations and Faster GC Analysis Faster GC Total Analytical Cycle Times A Variety of Approaches Pre-Run ALS Set-Up Chromatographic Run Post-Run Bake-Out Post-Run Cool-Down

More information

Deans Switch Microfluidics

Deans Switch Microfluidics TRACE 1300 and TRACE 1310 Gas Chromatographs Deans Switch Microfluidics Installation Guide 31709740 Revision A June 2014 2014 Thermo Fisher Scientific Inc. All rights reserved. TRACE 1300, and TRACE 1310

More information

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC Fast GC SPEEDY GC Slide 4 Optimization Goals Primary: Minimize time for the separation of a given number of peaks Secondary: Maximize the number of peaks separated by a given column Slide 5 HOW CAN THESE

More information

Agilent 6850 Series II Network GC System G2630A Performance Specifications

Agilent 6850 Series II Network GC System G2630A Performance Specifications IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 6850 Series II Network GC

More information

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO 8 SupelPRO Valves Order:.800..00 Technical Service:.800.9.0 Web: www.sigma-aldrich.com/supelco SupelPRO Automated Fluidics Instruments Supelco s SupelPRO series are precision, electronically-controlled,

More information

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Simulated Distillation Analyzers, Software, Standards, Consumables, Training Simulated Distillation Analyzers, Software, Standards, Consumables, Training www.separationsystems.com Offering the Fullest Range of Optimized Solutions Simulated distillation (SimDis) has been used to

More information

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column Cory S. Fix, Director of Application Development cory.fix@vgcchromatography.com Willie Steinecker,

More information

GC AND GC/MS. Your Essential Resource for Columns & Supplies

GC AND GC/MS. Your Essential Resource for Columns & Supplies GC AND GC/MS Your Essential Resource for Columns & Supplies GC AND GC/MS Achieve excellent, reproducible performance for difficult samples For over 40 years, Agilent has broken new ground with innovations

More information

Quick Reference Guide. Supplies for Waters HPLC Systems

Quick Reference Guide. Supplies for Waters HPLC Systems Quick Reference Guide Supplies for Waters HPLC Systems works with WATERS SHIMADZU THERMO/DIONEX BRUKER/VARIAN PERKINELMER CTC MORE Put innovation and quality to work on a wide range of GCs and HPLCs in

More information

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

Large Volume Injection of Polycyclic Aromatic Hydrocarbons JSB is an authorised partner of Large Volume Injection of Polycyclic Aromatic Hydrocarbons Application Note - Environmental #113 Author Anne Jurek Applications Chemist EST Analytical Cincinnati, OH Abstract

More information

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS Rev 1 3/6/2004 Selerity Technologies Inc. www.selerity.com SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS What is supercritical fluid chromatography? A chromatographic technique in

More information

Liquid Injection Techniques in GC and GC-MS

Liquid Injection Techniques in GC and GC-MS Liquid Injection Techniques in GC and GC-MS Inge De Dobbeleer Regional Marketing Manager GC and GC-MS, EMEA Thermo Fisher Scientific, Breda/The Netherlands The world leader in serving science Content Hot

More information

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard 7890 GC Standard Agilent Preventive Maintenance provides factory recommended service for your analytical systems to assure reliable operation and the accuracy of your results. Delivered by highly-trained

More information

Typical Gas Chromatographic System

Typical Gas Chromatographic System Page 72 Air Hydrogen Carrier Gas Typical Gas Chromatographic System Mol-Sieve Traps Fixed Restrictors Regulators Injection Port Detector Electrometer Cylinders or Generators Flow Controller Column Recorder/

More information

Instrument Supplies. Instrument Supplies from the specialists in chromatography 233

Instrument Supplies. Instrument Supplies from the specialists in chromatography 233 1997 Chromatography Products Catalog - Corporation 233 Instrument Supplies Leak Detectors Split Injector Sleeves Splitless Injector Sleeves Sleeve Packing Material CarboFrit Inlet Liners Direct Injection

More information

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System Chromatec Crystal 9000 Laboratory Gas Chromatography System GC Chromatec-Crystal 9000 Crystal 9000 is a leading gas chromatograph in Chromatec GC product line. Crystal 9000 has highest performances and

More information

Application Note. Abstract. Authors. Environmental Analysis

Application Note. Abstract. Authors. Environmental Analysis High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID using the Agilent Low Thermal Mass (LTM II) System Application Note Environmental Analysis Authors Frank David and Karine Jacq Research

More information

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application Petroleum Authors ChunXiao Wang Agilent Technologies (Shanghai) Co.,Ltd. 412 YingLun Road Waigaoqiao Free Trade Zone Shanghai

More information

Thermo Scientific TRACE GC Ultra Multi-channel gas chromatograph. Performance Beyond Limits

Thermo Scientific TRACE GC Ultra Multi-channel gas chromatograph. Performance Beyond Limits c h r o m a t o g r a p h y Thermo Scientific TRACE GC Ultra Multi-channel gas chromatograph Performance Beyond Limits Innovative advances for unprecedented reliability and productivity Ultra in system

More information

Split and Splitless Injection in Capillary Gas Chromatography

Split and Splitless Injection in Capillary Gas Chromatography Split and Splitless Injection in Capillary Gas Chromatography With Some Remarks on PTV Injection 3rd enlarged and revised Edition By Konrad Grob Hüthig Buch Verlag Heidelberg 1993 A Split Injection 1 Introduction

More information

Agilent 7890 Series Gas Chromatograph

Agilent 7890 Series Gas Chromatograph Agilent 7890 Series Gas Chromatograph Troubleshooting Agilent Technologies Notices Agilent Technologies, Inc. 2013 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Installing the 6850 Direct Valve Column Connector Kit

Installing the 6850 Direct Valve Column Connector Kit Use this kit to bypass the inlet and connect your 6850 gas or liquid sampling valve directly to a column. To use this kit, your 6850 GC must have a purged packed inlet. This kit contains: Installing the

More information

Agilent 7693A Automated Liquid Sampler

Agilent 7693A Automated Liquid Sampler Agilent 7693A Automated Liquid Sampler Specifications Overview The Agilent 7693A is a state-of-the-art sample handling and injection system that provides the highest levels of precision and reliability

More information

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent

More information

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Abstract High Temperature Simulated Distillation (High Temp SIMDIS) is one of the most frequently used techniques to determine

More information

260 Solvent Vapor Exit Accessory

260 Solvent Vapor Exit Accessory Theory of operation The Solvent Vapor Exit (SVE) is a GC accessory for performing large volume injections with a Cool On-Column inlet (COC). At the start of the run, the SVE solenoid valve is open as the

More information

One-Minute Essential Oils Characterization by Gas Chromatography through Nanovolume Injection

One-Minute Essential Oils Characterization by Gas Chromatography through Nanovolume Injection Application Note: 10100 One-Minute Essential Oils Characterization by Gas Chromatography through Nanovolume Injection Thermo Fisher Scientific Inc., Milan, Italy Key Words 1-minute Essential Oils Analysis

More information