DIRECT IMMERSION RESISTANCE THERMOMETER CONFIGURATIONS

Size: px
Start display at page:

Download "DIRECT IMMERSION RESISTANCE THERMOMETER CONFIGURATIONS"

Transcription

1 DIRECT IMMERSION RESISTANCE THERMOMETER CONFIGURATIONS WELDED THREADED CONNECTION II 1G/D Ex ia Pt100KI D20 D21 D26-1 D26-2 1

2 FEATURES The industrial thermometer configuration guarantees a short response time. The sensor is directly immersed into the medium. Fully welded construction. All assemblies offer a variety of protection heads to meet environmental and size requirements of most applications. High vibration resistant models available. TECHNICAL SPECIFICATION ASSEMBLY Connection head Aluminium With external earth terminal Ambient temperature range: -40/+100 C IP 6X protection degree (body cover) with oil-proof rubber O-ring, when used with correct cable gland Epoxy finish; colour blue RAL5015 Cover: hinged type or screw type with chain Sensor material: SS321 / Other on request ATEX : code A G=gas D=Dust IECEx : code I G=gas D=Dust Technical specification sensor insert High quality PT100 element with MgO mineral insulated metal sheathed cable, providing excellent stability and reproducibility. The unique properties make this basic element ideally suited for a wide range of applications up to 550 C. The PT100 is bendable over the total length except on the tip over 50 mm. Maximum temperature: 550 C Minimum insulation resistance: 1000 MOhm at 500VDC, ambient Conductors: material Cu Metal sheath: SS321 / Terminal block: -ceramic -hi-tech thermoplast: moisture and shockproof -mounting plate with flying leads Accuracy: according IEC DIN EN 60751: see table below 2

3 PKA PKB Terminal connection in the head CB RI TI Ceramic block 2/3/4/6/8 terminals Hi-tech thermoplast block 2/3/6 terminals Flying leads standard length 150 mm PT100 element S D Options Single Double HV: High vibration A1 A2 A3 A5 A6 A10 Accuracy Class A Class B 1/3 DIN 1/5 DIN 1/6 DIN 1/10 DIN IEC DIN EN ±( t ) C IEC DIN EN ±( t ) C 1/3 class B 1/5 class B 1/6 class B 1/10 class B Diameter D3 D3.2 D4.5 D4.8 D6 D mm 3.2 mm 4.5 mm 4.8 mm 6 mm 6.35 mm Connection W2 W3 W4 (*) 2 wire 3 wire 4 wire (*) for OD 3/3.2 /4.5/4.8 mm: dual sensors max. 2x3 wire 3

4 ORDERING INFORMATION PKA Sensor with ½ NPT threaded connection to the connection head PKB Reinforced sensor with ½ NPT threaded connection to the connection head Instrument connection (E) Cable connection Single (SC) Double (DC) P205 P405 P163 Other SC173 SC405 Other on on request G1/2 ½ NPT M18x1.5 M20x1.5 ½ NPT request Code Q410FT Certificates Functional test report (up-down) Q440CR Calibration report 0 C. Q450CR Q460CR Q820CC Q510TR Calibration report on 0 C and 1 up to 4 points in the range of -10/600 C Calibration report by notified body (measuring points to be indicated) Test report EN Transmitter programming (range and burn-out settings to be indicated) HOW TO ORDER (example) Code Example Your code Style Connection head with insert direct immersion D20 PT100 PT100 type PKA Terminal CB or RI or TI RI Protection A : Atex I : IECEx A Environment G: Gas D: Dust G Single/dual S: Single D: Dual T: Triple S Accuracy Class as per EN A1 Connection N of wires W3 Diameter OD sensor D6 Diameter OD reinforced part D0 Le length Length in mm below connection head Le200 Extension X Reinforced part under connection head Minimum length: 110 mm X0 4

5 Process P Connection to the process P405 SC Cable entry connection head SC173 Options Transmitter, cable glands, fitting, others 0rdering code example: D20 PKA RI A G S A1 W3 D6 D0 Le200 X0 P405 SC173 For all options: please contact Rodax Extension length For use in explosive atmosphere, the Temperature classes T6 T1 have to be respected. The table below will help you to choose the minimum extension length between process and connection head) for your application. Please contact us if other lengths are required. TP C TP TP TP TP TP T T T T T T

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS FOR USE WITH THERMOWELLS II 1G/D Ex ia Pt100RI/WI S10 S11 S16-1 S16-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration

More information

Direct immersion resistance thermometer

Direct immersion resistance thermometer Direct immersion resistance thermometer PLAIN STEM D100-101-102-103-160-162 CONFIGURATIONS General use RTD Product series PT100WT D100 D101 D102 D103 D160 D162 2 Features assembly The sensor can be immersed

More information

Spring loaded resistance thermometer

Spring loaded resistance thermometer Spring loaded resistance thermometer THERMOWELL & REPLACEABLE INSERT C200-201-204-205-260-262 CONFIGURATIONS Ex ia RTD Product series PT100RI/WI C200 C201 C204 C205 C260 C262 2 Features assembly The industrial

More information

Spring loaded resistance thermometer

Spring loaded resistance thermometer Spring loaded resistance thermometer FOR USE WITH TRANSMITTER HOUSING AND THERMOWELLS PIA CONFIGURATIONS Ex ia RTD Product series PT100WI Table 1: Measuring inserts main model PIA Terminal Spring loaded

More information

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35 WIKA data sheet TE 60.03 for further approvals see page 7 Applications Machinery,

More information

Resistance thermometer Model TR10-E, for additional thermowell

Resistance thermometer Model TR10-E, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-E, for additional thermowell WIKA data sheet TE 60.05 further approvals see page 6 Applications Chemical industry Petrochemical industry

More information

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module Electrical temperature measurement Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module WIKA data sheet TE 60.17 for further approvals see page 6 Applications

More information

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C... EJB Enclosures ATEX and IECEx Zone 1 certified Explosion proof Marine grade copper-free aluminium IP66 The EJB Series is a range of explosion-proof enclosures, available in either aluminium alloy (EJB)

More information

ABG Cable Glands Installation Procedure

ABG Cable Glands Installation Procedure ABG Cable Glands Installation Procedure ABG Cable Gland Range Baseefa 16ATEX0004X IECEx BAS 16.0011X Installation, Operation and Maintenance Instructions Material: Brass/ Brass with Nickel plated and Stainless

More information

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 Electrical temperature measurement Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 WIKA data sheet TE 60.06 for further approvals see page 6 Applications Machine building,

More information

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Resistance thermometer Model TR10-L, Ex d, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-L, Ex d, for additional thermowell WIKA data sheet TE 60.12 for further approvals see page 6 Applications Chemical industry Petrochemical

More information

New products Ex Equipment 2015

New products Ex Equipment 2015 New products Ex Equipment 2015 ROSE Systemtechnik GmbH ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany, in 199 and is today one of the world s leading and innovative providers of industrial

More information

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic. Industrial Temperature Assemblies measuring monitoring analysing MWD OO Meassuring range -200...+600ºC. OO Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic. OO Output: Resistance or analogue

More information

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5

More information

Thermocouple with spring-loaded tip Model TC55

Thermocouple with spring-loaded tip Model TC55 Electrical temperature measurement Thermocouple with spring-loaded tip Model TC55 WIKA data sheet TE 65.55 for further approvals see page 5 Applications Bearing temperature measurement on: Pumps Gears

More information

Measuring insert for resistance thermometer Model TR10-A

Measuring insert for resistance thermometer Model TR10-A Electrical temperature measurement Measuring insert for resistance thermometer Model TR1-A WIKA data sheet TE 6.1 for further approvals see page 6 Applications Replacement measuring insert for servicing

More information

Omnigrad S -TC65. Technical Information

Omnigrad S -TC65. Technical Information Technical Information Omnigrad S T65 Thermocouple thermometer EExd certified, no replaceable insert, no thermowell, process connection threaded fixed or compression fitting PP (4...20 ma), HART or PROFIBUSPA

More information

Industrial Pt100 RTD's

Industrial Pt100 RTD's CA 2001 Resistance Welded process connection measuring insert. Can be Type CA 2001 CA 2003 Resistance Welded process connection 1/2"BSP Head extension 50mm standard. Aluminium Replaceable 6mm Din insert.

More information

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-V Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications

More information

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom Annex to IECEx Certificate of Conformity Equipment Range: The design variants covered are either: a) Complete

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical

More information

Resistance thermometer Without thermowell Model TR10-H

Resistance thermometer Without thermowell Model TR10-H Temperature Resistance thermometer Without thermowell Model TR10-H WIKA data sheet TE 60.08 for further approvals see page 2 Applications For direct installation into the process Machine building Motors

More information

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J Electrical temperature measurement Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J WIKA data sheet TE 60.10 for further approvals see page 7 Applications Ventilation

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

INTERNATIONAL METAL ENGINEERING

INTERNATIONAL METAL ENGINEERING INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

Tubeskin thermocouple assembly Model TC59-W

Tubeskin thermocouple assembly Model TC59-W Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-W WIKA data sheet TE 65.58 further approvals see page 7 WELD-PAD Applications Chemical industry Power generation Refineries

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600 > 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600

More information

RTD Temperature Sensor omnigrad M TR 15

RTD Temperature Sensor omnigrad M TR 15 Technical Information TI 260T/02/en 60019739 RTD Temperature Sensor omnigrad M TR 15 RTD assembly with flanged or weld-in process connection With bar-mounting thermowell and replaceable insert PCP (4...20

More information

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-V Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications

More information

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600 > 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series

More information

Thermocouple Model TC10-H without thermowell

Thermocouple Model TC10-H without thermowell Electrical temperature measurement Thermocouple Model TC10-H without thermowell WIKA data sheet TE 65.08 for further approvals see page 7 Applications For direct installation in the process Machine building

More information

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

BETA SWITCHES FOR HAZARDOUS AREA

BETA SWITCHES FOR HAZARDOUS AREA BETA offers complete line of switches for (classified) hazardous locations! The BETA Switch, well known as a safety instrument, adds an extra dimension to industrial safety by having area approval up to

More information

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER PRESSURE PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE The PYRP-28 pressure transmitter is suitable for the measurement of pressure, vacuum and absolute pressure of gases, vapours and liquids for industrial

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 11 Applications For direct installation into the process Machine building

More information

Thermocouple Without thermowell Model TC10-H

Thermocouple Without thermowell Model TC10-H Temperature Thermocouple Without thermowell Model TC10-H WIKA data sheet TE 65.08 for further approvals see page 2 Applications For direct installation into the process Machine building Motors Bearing

More information

Glass Reinforced Polyester Enclosures

Glass Reinforced Polyester Enclosures 42 The GRP range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,

More information

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip Electrical Temperature Measurement Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip WIKA Data Sheet TE 60.22 Applications Temperature measurement at bearings of: T Pumps T Gears T Motors

More information

Linear luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002 > latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

RTD Temperature Sensor omnigrad M- TR 11

RTD Temperature Sensor omnigrad M- TR 11 Technical Information TI 257T/02/en 60019736 RTD Temperature Sensor omnigrad M- TR 11 RTD assembly without extension neck With thermowell and replaceable insert PCP (4...20 ma), HART or PROFIBUS-PA electronics

More information

Resistance thermometer Model TR10-B, for additional thermowell

Resistance thermometer Model TR10-B, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-B, for additional thermowell WIKA data sheet TE 60.02 Applications Machine building, plant and tank construction Energy and power plant

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

Control and Terminal Box Type A21-**-*****

Control and Terminal Box Type A21-**-***** e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de

More information

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series Ex d S S.1 series - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67 SSC series Temperature sensor box SWS series SF series A.117 S... series Junction boxes

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35 Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35 WIKA Data Sheet TE 60.03 Applications Machinery, plant and tank construction Energy

More information

Load disconnect switch Series 8146/5-V11

Load disconnect switch Series 8146/5-V11 www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation

More information

Technical Information Omnigrad TST90, TET90

Technical Information Omnigrad TST90, TET90 TI01109T/09/EN/02.13 71214205 Products Solutions Services Technical Information Resistance thermometer and insert for thermal energy measurement High-precision measurement of temperature differences with

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 2 Applications For direct installation into the process Machine building

More information

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4 Table of contents Page Specifications 2 Applications 4 ------------------------------------------------------------------------------------------------------------ CN 4020 5 Short extension length ------------------------------------------------------------------------------------------------------------

More information

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 bar up to 0... 600

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Thermocouples Model TC10-E, for Additional Thermowell

Thermocouples Model TC10-E, for Additional Thermowell Electrical Temperature Measurement Thermocouples Model TC10-E, for Additional Thermowell WIKA Data Sheet TE 65.05 Applications Chemical industry Petrochemical industry Off-Shore Machine building, plant

More information

Mineral Insulated Resistance Thermometers (RTD)

Mineral Insulated Resistance Thermometers (RTD) Mineral Insulated Resistance Thermometers (RTD) Electronic Temperature Measurement Data sheet : MIRTD/2012 Contents Page RTD Element Type 2 Conductors & Number of Wires 2 Probe Diameter 3 Length Types

More information

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter Manual Change No. 09-001-5E Please use attached sheets for the pages listed below in (10th). Page Page 10-2 EMC Conformity

More information

I Ex-safety switches I

I Ex-safety switches I EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX

More information

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit > A Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation

More information

Thermocouple For additional thermowell Model TC10-B

Thermocouple For additional thermowell Model TC10-B Temperature Thermocouple For additional thermowell Model TC10-B WIKA data sheet TE 65.02 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy and power plant

More information

Thermocouple Model TC10-E, for additional thermowell

Thermocouple Model TC10-E, for additional thermowell Electrical temperature measurement Thermocouple Model TC10-E, for additional thermowell WIKA data sheet TE 65.05 Applications Chemical industry Petrochemical industry Offshore Machine building, plant and

More information

7 Lighting Technology

7 Lighting Technology 7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:

More information

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K Temperature Measuring insert For thermocouple with flameproof enclosure (TC1-L) Model TC1-K WIKA data sheet TE 65.11 for further approvals see page 2 Applications Replacement measuring insert for servicing

More information

Measuring insert for process resistance thermometer

Measuring insert for process resistance thermometer Electrical temperature measurement Measuring insert for process resistance thermometer Model TR12-A WIKA data sheet TE 60.16 for further approvals see page 2 Applications Replacement measuring insert for

More information

Cable thermocouple Model TC40

Cable thermocouple Model TC40 Electrical temperature measurement Cable thermocouple Model TC40 WIKA data sheet TE 65.40 for further approvals see page 11 Applications For direct installation into the process Machine building Motors

More information

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell Electrical Temperature Measurement Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell WIKA Data Sheet TE 60.15 Applications T Machinery, plant and tank construction T Energy

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

LED Linear Luminaire Series EXLUX 6402

LED Linear Luminaire Series EXLUX 6402 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

RTD Temperature Sensor omnigrad M- TR 13

RTD Temperature Sensor omnigrad M- TR 13 Technical Information TI 259T/02/en 60019738 RTD Temperature Sensor omnigrad M- TR 13 RTD assembly with flanged process connection With thermowell and replaceable insert PCP (4...20 ma), HART or PROFIBUS-PA

More information

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6409/1 > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually

More information

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC > For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central

More information

Surface thermocouple Model TC50

Surface thermocouple Model TC50 Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES Ex d IIB+H 2 ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES ALUMINIUM ENCLOSURES STAINLESS STEEL ENCLOSURES EJB... series enclosures offer Ex d IIB +H 2 mode of protection. These enclosures are

More information

Junction box for EKL light

Junction box for EKL light M EKL light Junction box Junction box for EKL light Features Chemical-resistant Temperature-resistant Flame-retardant Absolutely corrosion-proof Seawater-proof Description Polyester enclosures have proven

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.

More information

Plastic tube variable area flowmeter for liquids and gases

Plastic tube variable area flowmeter for liquids and gases Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 40

More information

M-0. M-0... series control, monitoring and signalling devices. Ex e

M-0. M-0... series control, monitoring and signalling devices. Ex e M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere

More information

Terminal Boxes TNCN. Explosion protection Marking

Terminal Boxes TNCN. Explosion protection Marking Terminal boxes TNCN Terminal Boxes TNCN The TNCN range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main box is manufactured

More information

RTD PT100 Insert With Solid Drilled Flanged Thermowell

RTD PT100 Insert With Solid Drilled Flanged Thermowell RTD PT100 Insert With Solid Drilled Flanged Thermowell Product Data Sheet RTINTWFL 2017 rev1.00 Full temperature sensor & thermowell assemblies. Consisting of a temperature sensing element housed in a

More information

Rosemount 68 Sensor and Thermowell

Rosemount 68 Sensor and Thermowell Rosemount 68 Sensor and Thermowell The Rosemount 78 Sensor and Thermowell have designs that provide flexible and reliable temperature measurements in process environments. Features include: Industry-standard

More information

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B

TWL-Exia. Resistance Thermometers according to DIN. Ignition Protection Exia. Pt 100-sensor class A respectively class B Resistance Thermometers according to DIN Ignition Protection Exia measuring monitoring analysing TWL-Exia O O Measuring range: -...+600 C OO Pt 100-sensor class A respectively class B OO Output: resistance

More information

Safety switches for hinged doors

Safety switches for hinged doors 4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland

More information

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning

More information

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400 > As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in

More information

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Applications Instrumentation junction boxes are used to run process or remote information to control room. For

More information

Thermocouple Thermometer omnigrad M -TC 12

Thermocouple Thermometer omnigrad M -TC 12 Technical Information TI 275T/02/en 60022267 Thermocouple Thermometer omnigrad M TC 12 Replaceable insert and thermowell with compression fitting PCP (4...20 ma), HART or PROFIBUSPA electronics The TC

More information

Terminal Boxes in Stainless Steel SLS**.T

Terminal Boxes in Stainless Steel SLS**.T Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations

More information

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 further approvals see page 11 Applications For direct installation into the process Machine building

More information