SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION
|
|
- Andrea Walker
- 5 years ago
- Views:
Transcription
1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION Valid to: September 22, 2019 Certificate Number: L Length Dimensional Metrology Indicators - LVDT s ¹ Up to 2 in Up to 10 in 66 µin 185 µin procedures Microscopes ² Eyepiece Reticules and Video Systems Magnification (0 to 1) in (0 to 25) mm 110 µin 7 µm 355 µin 20 µm ASTM E 1951 Mass and Mass Related Force gauges and sensors used in force measurement applications, tension and compression 1 Force gauges and sensors used in force measurement applications, tension and compression ¹ Testing Machines / Load Cells Compression ¹ (0.1 to 1 000) lbf 0.1% of reading (0.5 to ) lbf 0.08% of reading NIST Class F Weights reference load cell (0.01 to ) lbf 0.15% of reading ASTM E4 Page 1 of 8
2 Testing Machines / Load Cells Tension ¹ Testing Machines / Load Cells Compression ¹ Testing Machines / Load Cells Tension ¹ Extensometers / Deflectometers / COD Gauges ² Gauge Length Measure (0.01 to ) lbf 0.15% of reading ASTM E4 (1 200 to ) lbf 0.25% of reading (1 200 to ) lbf 0.25% of reading (0 to 2) in (1 to 10) in Up to 8 in 44 µin 183 µin 0.016% of reading ISO Class 1 ISO Class 1 ASTM E 83 and ISO 9513 Strain Rate ² (0 to 0.5) in/in/min 0.24 % of reading procedures Testing Machine Displacement ² (0.01 to 25) in in ASTM E 2309 Testing Machine Speed ² (0.05 to 20) in/min 0.16 % of reading ASTM E 2658 NIST Class F ASTM E617 Class 6 ASTM E617 Class 7 50 lb 25 lb 20 lb 10 lb 5 lb 2 lb 1 lb 0.5 lb 0.2 lb 0.1 lb 0.05 lb 0.02 lb 0.01 lb 75 mg 40 mg 35 mg 20 mg 10 mg 5 mg 0.5 mg 0.25 mg 0.25 mg 0.07 mg 0.05 mg Comparison of Unknown Mass to Known Mass ASTM E617 Class 1, Class 4 Weights Page 2 of 8
3 NIST Class F ASTM E617 Class 6 ASTM E617 Class 7 Micro-Balances 2 (0.1 μg resolution) (0.1 μg resolution) (1 μg resolution) (1 μg resolution) (10 μg resolution) (10 μg resolution) (10 μg resolution) (10 μg resolution) Analytical Balances 2 ( g resolution) Top Loading Balances 2 (0.001 g resolution) (0.01 g resolution) (0.1 g resolution) (1 g resolution) Bench Scales 2 (0.001 lb resolution) (0.01 lb resolution) Floor Scales, Tanks and Hoppers 2 (0.1 lb resolution) (1 lb resolution) (10 lb resolution) g g g g g 500 g 200 g 100 g 50 g 30 g 20 g 10 g 5 g 3 g 2 g 1 g 0 g to 1 g 0 g to 2.1 g 0 g to 5 g 0 g to 31 g 0 g to 5 g 0 g to 20 g 0 g to 100 g 0 g to 230 g 75 mg 35 mg 20 mg 6 mg 5 mg 1 mg 0.2 mg 0.15 mg 4.8 μg 4.8 μg 8 μg 25 μg 40 μg 45 μg 65 μg 130 μg 0 g to 610 g 0.75 mg 0 g to g 0 g to g 0 g to g 0 g to g 0 lb to 50 lb 0 lb to 300 lb 0 lb to lb 0 lb to lb 0 lb to lb 3.1 mg 31 mg 0.3 g 2.6 g lb 0.03 lb 0.3 lb 2.6 lb 24 lb Comparison of Unknown Mass to Known Mass ASTM E617 Class 1, Class 4 Weights ASTM E617 Class 1 Weights ASTM E617 Class 1 Weights NIST Class F Weights NIST Class F Weights Page 3 of 8
4 Crane and hanging scales 2 (1 lb resolution) 0 lb to lb 1.7 lb Crane and hanging scales 2 (0.5 lb resolution) (1 lb resolution) (10 lb resolution) (50 lb resolution) 0 lb to lb 0 lb to lb 0 lb to lb 0 lb to lb 1.5 lb 5.5 lb 26 lb 875 lb reference load cell Weigh Pads & Load Cells (1 lb resolution) (10 lb resolution) 0 lb to lb 0 lb to lb 5.5 lb 26 lb reference load cell Moisture Analyzers 2 Weighing Systems Analytical Balances ( g) Resolution 0 to 610 g 0.75 mg Method tolerances ASTM E617 Class 1 weights Top Load (0.001 g) Resolution 0 to g 3.1 mg Temperature 20 C to 200 C 2.9 C Reference Thermometer Torque Transducers and Testers 1 (0.01 to 1 000) lbf ft 0.32% of reading Torque Hand Tools (0.5 to 1 000) lbf ft 0.57% of reading Brinell Hardness Testers ² (62.5 to 3 000) kgf 0.16 % of reading Brinell Hardness Testers ² (62.5 to 3 000) kgf Repeatability: 7.5 HBW Error: 0.06 mm NIST Class F Weights and reference wheel/arm standards reference transducer Direct Verification to ASTM E10 ASTM E10 Page 4 of 8
5 Brinell Scopes ¹ (0 to 10) mm 0.05 mm Leeb Hardness HLD 11.3 HLD Direct Verification to ASTM E10 Indirect Verification ASTM A956 Page 5 of 8
6 HRA Low HRA Mid HRA High 0.44 HRA 0.35 HRA 0.26 HRA HRBW Low HRBW Mid HRBW High 0.71 HRBW 0.69 HRBW 0.59 HRBW HRC Low HRC Mid HRC High 0.40 HRC 0.40 HRC 0.36 HRC HREW Low HREW Mid HREW High 0.57 HREW 0.61 HREW 0.54 HREW Indirect Verification of Rockwell Hardness Testers ² HRFW Low HRFW Mid HRFW High 0.70 HRFW 0.52 HRFW 0.58 HRFW ASTM E18 HRGW Low HRGW Mid HRGW High 0.58 HRGW 0.60 HRGW 0.46 HRGW HRHW Mid HRHW High 0.45 HRHW 0.49 HRHW HRKW Low HRKW Mid HRKW High 0.54 HRKW 0.61 HRKW 0.46 HRKW HRLW Mid HRLW High 0.49 HRLW 0.43 HRLW HRMW Mid HRMW High 0.60 HRMW 0.45 HRMW HRRW High 0.57 HRRW Page 6 of 8
7 HR15N Low HR15N Mid HR15N High 0.48 HR15N 0.57 HR15N 0.39 HR15N HR30N Low HR30N Mid HR30N High 0.72 HR30N 0.57 HR30N 0.51 HR30N Indirect Verification of Rockwell Superficial Hardness Testers ² HR45N Low HR45N Mid HR45N High HR15TW Low HR15TW Mid HR15TW High 0.49 HR45N 0.54 HR45N 0.50 HR45N 0.60 HR15TW 0.61 HR15TW 0.39 HR15TW ASTM E18 HR30TW Low HR30TW Med HR30TW High 0.52 HR30TW 0.50 HR30TW 0.45 HR30TW HR45TW Low HR45TW Med HR45TW High 0.52 HR45TW 0.58 HR45TW 0.61 HR45TW Indirect Verification of Micro- Hardness Indentation Testers (Knoop) ² Indirect Verification of Micro- Hardness Indentation Testers (Vickers) ² (100 to 250) HK (250 to 650) HK (100 to 240) HV (240 to 600) HV (> 600) HV 0.9 % of reading 0.5 % of reading 0.6 % of reading 0.7 % of reading 0.3 % of reading ASTM E92 / ISO Uncertainty is stated as repeatability per ASTM E92 X-Y Stage Up to 1 in Up to 25 mm 350 µin 9 µm Page 7 of 8
8 Charpy Impact Testers ² Charpy Impact Testers ² 2092 (Low) 2096 (High) 2098 (Super High) 30 J 80 J 120 J 1.3 ft/lbf 2.5 ft/lbf 3.2 ft/lbf 1.6 J 3.5 J 6.7 J ASTM E 23 ISO Calibration and Measurement Capability (CMC) is expressed in terms of the measurement parameter, measurement range, expanded uncertainty of measurement and reference standard, method, and/or equipment. The expanded uncertainty of measurement is expressed as the standard uncertainty of the measurement multiplied by a coverage factor of 2 (k=2), corresponding to a confidence level of approximately 95%. Notes: 1. Laboratory offers calibration services at the laboratory's own facilities and at the client or other agreed upon facilities. 2. On-site calibration service is offered for these parameters. 3. This scope is formatted as part of a single document including Certificate of Accreditation No. L Page 8 of 8
Accredited Laboratory
Accredited Laboratory A2LA has accredited CAL-RITE CORPORATION Naperville, IL for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CAL-RITE CORPORATION 1665 Quincy Avenue, Suite 103 Naperville, IL 60540 Michael Crosby Phone: 630 355 1522 CALIBRATION Valid To: December
More informationPage 1 of 5. United Testing Systems, Inc S. Acacia Avenue Fullerton, CA William Warner, Quality Manager
IAS Accreditation Number Accredited Entity Address CL-128 1375 S. Acacia Avenue Fullerton, CA 92831 William Warner, Quality Manager Contact Name Telephone +1 (714) 638-2322 Effective Date of Scope July
More informationScope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis
Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX 77060 Gavin Lewis 832-428-2737 In recognition of a successful assessment to ISO/IEC 17025:2005
More informationMetallic materials Rockwell hardness test. Part 2: Verification and calibration of testing machines and indenters
Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 6508-2 Third edition 2015-03-01 Metallic materials Rockwell hardness test Part 2: Verification and calibration of testing machines and indenters
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Schedule of ccreditation United Kingdom ccreditation Service Issue No: 028 Issue date: 10 pril 2018 ccredited to 6 Banner Park Wickmans Drive Coventry CV4 9X Contact: Keith rnold Tel: +44 (0)2476 426 316/317
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationPage : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *
Metrix Precision Pte Ltd Certificate No. : LA-2014-0581-C No. 23 Tagore Lane #02-03/04 Tagore 23 Warehouse Issue No. : 2 Singapore 787601 Date : 29 July 2016 FIELD OF TESTING : Calibration and Measurement
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 RIVERVIEW CALIBRATION SERVICES, LTD 5706 Veto Road Belpre, OH 45714 J. Michael Pennell Phone: 740 678 8625 CALIBRATION Valid To: July
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORYACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 NORTHERN BALANCE AND SCALE, INC. 9556 W. Bloomington Freeway Bloomington, MN 55431 Joey Kaluser Phone: 952 881 7716 CALIBRATION Valid
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 EMPIRE SCALE CORPORATION d.b.a. PRECISION SCALE & BALANCE d.b.a. EMPIRE SCALE & BALANCE 140 Rotech Drive Lancaster, NY 14086 Margery
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 METTLER TOLEDO (INDUSTRIAL) 1900 Polaris Parkway Columbus, OH 43240 Frank Gardone Phone: 412 213 2263 CALIBRATION Valid To: April 30,
More informationSCOPE OF ACCREDITATION TO ISO/IEC & KS Q ISO/IEC
SCOPE OF ACCREDITATION TO ISO/IEC 17025-2005 & KS Q ISO/IEC 17025-2006 Korea Instrument Co., Ltd. Branch 45, Gwangjang-ro 56beon-gil, Sasang-gu, Busan 46976 Phone : 051-322-0880, Fax : 051-322-4066, E-mail
More informationHi-Tech Calibration, 307, 3rd Floor, Govinda Complex, Char Rasta, Vapi, Gujarat. Discipline Mechanical Calibration Issue Date
Last Amended on 18.01.2016 Page 1 of 7 I. DIMENSIONS 1. CALIPER $ (Vernier, Dial, Electronics) L.C.0.01 mm up to 1000mm 24 µm Using Caliper Checker / L.C.0.02 mm up to 600mm 19 µm Length Bars /Slip Gauges
More informationSchedule. 300 mm to 600 mm 600 mm to 1000 mm inch to 12 inch
LABORATORY LOCATION: (PERMANENT LABORATORY) MITUTOYO (M) SDN. BHD. MAH SING INTEGRATED INDUSTRIAL PARK BANDAR PINGGIRAN SUBANG 4, JALAN UTARID U5/14, SECTION U5 40150 SHAH ALAM SELANGOR, MALAYSIA Page:
More informationSchedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.
Page: 1 of 9 LABORATORY LOCATION: (PERMANENT LABORATORY) PPCALIBRATION SERVICES SDN. BHD. NO. 15, MEDAN BUKIT EMAS PUSAT PERNIAGAAN BUKIT EMAS 14000 BUKIT MERTAJAM, PULAU PINANG MALAYSIA This laboratory
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 METTLER TOLEDO (INDUSTRIAL) 1900 Polaris Parkway Columbus, OH 43240 Frank Gardone Phone: 412 213 2263 CALIBRATION Valid To: April 30,
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that SP Metrology System Thailand Co., LTD 88/115
More informationCalibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5
National Research Council Conseil national de recherches Canada Canada Measurement Standards and Science Science des mesures et étalons Calibration Laboratory Assessment Service CLAS Certificate Number
More informationAnnex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 11140 18 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 06.11.2014 to 05.11.2019 Holder of certificate: Fraunhofer
More informationFor the National Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Florida Department of Agriculture Metrology Laboratory 3125 Conner Blvd. Lab #2 Tallahassee, FL 32399-1650 Ms. Amy Smith Phone: 850-921-1570 Fax: 850-921-1593
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Torreón, Coahuila, México C.P. 27019 (Hereinafter
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALDINGER COMPANY 1440 Prudential Drive Dallas, TX 75235 Timothy R. Detten Phone: 214 638 1808 CALIBRATION Valid To: July 31, 2018 Certificate
More informationCalitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra
Last Amended on 12.09.2014 Page 1 of 7 I. MASS 1. Weights $ (Conventional Mass) 1 mg 0.015 mg Using Weights of 2 mg 0.015 mg accuracy Class F1 and 5 mg 0.015 mg 10 mg 0.015 mg 20 mg 0.020 mg 50 mg 0.020
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 QUALITY CONTROL SERVICES, INC. 2340 SE 11 th Avenue Portland, OR 97214 George Cahill Phone: 503 236 2712 CALIBRATION Valid To: September
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT CLEVELAND 5405 East Schaaf Road Cleveland, OH 44131 Jeffry J Smith Phone: 216 524 1450 Jeffry.Smith@element.com MECHANICAL Valid To: October 31, 2018
More informationCALIBRATION SYSTEM CERTIFICATE
CALIBRATION SYSTEM CERTIFICATE With respect to products (measuring instruments and testing instruments), we hereby certify that we have established our calibration system traceable to the national (international)
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Garber Metrology Weighing Solutions & Precision
More informationWelcome to Garber C O R P O R AT E O V E R V I E W
CORPORATE OVERVIEW Garber Metrology is one of the only companies in the Mid-Atlantic Region that combines full service weighing solutions, a wide range of calibration /metrology services and a broad scope
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Monterrey, Nuevo León, 64920 (Hereinafter called the
More informationArticle: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE
Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE 26th September 2017 For over a decade, both regional ECA and global sulphur limits within marine fuels have
More informationSelecting Weights and Certificates
11 Weight Selection There are several shapes, designs and sizes available to meet your needs. Selecting the proper weight for your application can be confusing given the number of weight classes, designs,
More informationAutocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra
Last Amended on - Page 1 of 5 I. DIMENSION 1. CALIPER (Vernier/Dial/Digital) L. C. : 10µm Φ 0 to 600 mm 16 µm Using Caliper Checker & External Micrometer by 2. DEPTH GAUGE (Vernier/Dial/ Digital) L. C.
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 EUSTIS CO., INC./PYROCOM CALIBRATION LAB 12407-B Mukilteo Speedway Lynnwood, WA 98087 Bill LeMesurier Phone: 425 423 9996 CALIBRATION
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Mexical Metrología, S.A. de C.V. Tecnología de Materiales,
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MNP CORPORATION TECHNICAL AND RESEARCH SERVICES 1 (Corporate Facility) 44225 Utica Road Utica, MI 48317 Chad Clifford Phone: 586 254 1320 MECHANICAL Valid To:
More informationThe FMM force tester can be controlled using L1 software for limit, cycling, hold and coefficient of friction testing.
FMM FMM may be used with L1 software or with a Starrett DFC or DFG digital force gage. FMM digital force testers are compact and ideal for highvolume, lean manufacturing production. FMM testers are available
More informationShriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka
Certificate Number CC-2083 (in lieu of C-0216, C-0304, C-1497) Page 1 of 7 ELECTRO-TECHNICAL CALIBRATION I. MEASURE 1. Time $ 5 sec to 9900 sec 0.12 sec to 5.8 sec Using Digital Time Totalizer (Digital
More informationAccurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date
Last Amended on 11.11.2014 Page 1 of 6 I. DIMENSION 1. Dial/ Digital Vernier Caliper $ L.C.: 0.01mm Φ 0 to 200 mm 7.5 µm Using Slip Gauge Set & L.C.: 0.01mm Φ 0 to 300 mm 12.17 µm Using Slip Gauges & Caliper
More informationMTS Criterion Series 40 Specifications - Comparative
MTS Criterion Series 40 Specifications - Comparative Model 41 Model 42 Model 43 Model 44 C41.103 C42.503 C43.104 C43.304 C43.504 C44.104 C44.304 Maximum Rated kn 1 5 10 30 50 10 30 Force Capacity lbf 220
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 RS CALIBRATION SERVICES, INC. 1047 Serpentine Lane Pleasanton, CA 94566 Mr. Ralph Sabiel Phone: 925 462 4217 CALIBRATION Valid To: September
More informationRe: Extension for ISO/IEC 17025: 2005 accreditation Certificates #ACT-1997, ACT , ACT & AT
October 17, 2017 VIA EMAIL Link Engineering Company Jim Villella 401 Southfield Road Dearborn, MI 48120 Re: Extension for ISO/IEC 17025: 2005 accreditation Certificates #ACT-1997, ACT-1997.01, ACT-1997.02
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. SCHAP LABORATORY SERVICES, LLC Taft Road, Unit 5 Spring Lake, MI Erik Johnson Phone:
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCHAP LABORATORY SERVICES, LLC 17309 Taft Road, Unit 5 Spring Lake, MI Erik Johnson Phone: 616 846 6530 MECHANICAL Valid To: June 30, 2020 Certificate Number:
More informationASTM E74-13a Explained
ASTM E74-13a Explained Henry Zumbrun II, President Morehouse Instrument Company 1742 Sixth Ave York, PA 17403 PH: 717-843-0081 web: www.mhforce.com info: hzumbrun@mhforce.com 1 What we do We are a manufacturing
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 RS CALIBRATION SERVICES, INC. 1047 Serpentine Lane Pleasanton, CA 94566 Mr. Ralph Sabiel Phone: 925 462 4217 CALIBRATION Valid To: June
More informationStandard Calibration Certificate
Mettler Toledo Service Business Unit Laboratory 1900 Polaris Parkway Columbus, OH 43240 1-800-METTLER Customer Standard Calibration Certificate Company: ABC Pharma Incorporated Address: 1432 East 9th Street
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 BUREAU VERITAS CONSUMER PRODUCTS SERVICES MEXICO, S.A. DE C.V.-PUEBLA 1 Circuito del Sol 3905-01 Colonia Nuevo Amanecer Puebla, Puebla 72400, Mexico Alicia
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: UNEX/HYTORC, 333 Route 17 North, Mahwah, NJ 07430
More informationStandard Calibration Certificate
Mettler Toledo Service Business Unit Laboratory 1900 Polaris Parkway Columbus, OH 43240 1-800-METTLER Customer Standard Calibration Certificate Company: Address: Allied Food Processing 3433 West High Street
More informationSPECIALTY WEIGHTS CALIBRATION WEIGHTS
SPECIALTY WEIGHTS Unique weights designed or built for custom applications or tolerances NIST ASTM 228 Applications: Tolerance test or checking Equipment verification in unique units of measurement Slotted
More informationMorehouse Instrument Company
The Morehouse Universal Calibrating Machine is designed to use a compression force standard, proving ring or load cell to calibrate units under test in compression and tension. The reference standard and
More informationAccurate Labs, 311, 312 Govinda Complex, GIDC Char Rasta, Vapi, Valsad, Gujarat. Discipline Mechanical Calibration Issue Date
Last Amended on - Page 1 of 9 I. DIMENSION 1. CALIPER $ Vernier L.C. 0.01mm 7.5 µm 9.0 µm Using Caliper Checker & Slip Gauges L.C. 0.05mm 29.5 µm 30.0 µm Dial / Electronic L.C. 0.02mm 12.5 µm 13.5 µm 2.
More informationMAGNETIC DIGITAL ROCKWELL HARDNESS TESTER
USER'S MANUAL PHR-200 MAGNETIC DIGITAL ROCKWELL HARDNESS TESTER TX TX TESTING INSTRUMENTS CO.,LTD. No.17-1 Wensu Street, Hunnan District Shenyang City 110168 Tel:+86-24-24238668 Fax:+86-24-24230008 http://
More informationHellenic Accreditation System. Annex F2/17 to the Certificate No SCOPE of ACCREDITATION
Hellenic Accreditation System Annex F2/17 to the Certificate No. 263-5 SCOPE of ACCREDITATION of the Testing & Calibration Laboratory of LINK LAB LTD for the performance of calibrations Measurand / Spectrophotometric
More informationFlow Research and Test Center. Creating resource technology for today and tomorrow.
Flow Research and Test Center Creating resource technology for today and tomorrow. "The Measurement Solutions Flow Research and Test Center in Erie is certainly one of the gems of our corporation s technological
More informationAlcalab Private Limited, 3rd Floor, Ashiana Trade Centre, Adityapur, Jamshedpur, Jharkhand. Discipline Mechanical Calibration Issue Date
Last Amended on - Page 1 of 11 I. DIMENSIONS 1. SLIP 0.5 mm to 25 mm 0.25 μm Using Slip Gauge (K-Grade) & > 25 mm to 50 mm 0.34 μm Double Probe Comparator > 50 mm to 75 mm 0.46 μm > 75 mm to 100 mm 0.58
More informationInstitute for Design of Electrical Measuring Instruments, Swatantryaveer Tatya Tope Marg, Chunabhatti, Sion, Mumbai, Maharashtra
Last Amended on 02.09.2014 Page 1 of 10 I. DIMENSION 1 Calipers $ Up to 600 mm 10.4 µm Using Caliper Checker by Up to 1000 mm 13.2 µm Using Long Slip Gauge by 2 Height Gauges $ Up to 600 mm 12.8 µm Using
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration)
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration) Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane Author:
More informationMANUAL TH-134 TH-134
MANUAL TH-134 TH-134 CONTENTS 1. INTRODUCTION 2 1.1 IMPACT TH-134 visualized 2 1.2 General description 3 1.3 Typical applications 3 1.4 Technical specification 3 1.5 Table of measuring range versus material
More informationPortable Hardness Tester TIME Ultrasonic Contact Impedance (UCI) Method
Portable Hardness Tester TIME5620 -Ultrasonic Contact Impedance (UCI) Method Larger, clear screen displays probe information, battery information, the average, maximum, minimum readings of select hardness
More informationDiscipline Mechanical Calibration Issue Date Certificate Number C-0752 Valid Until Last Amended on - Page 1 of 6
Last Amended on - Page 1 of 6 I DIMENSION 1. Caliper $ (Vernier/Dial/Digital) LC : 0.01mm 0 to 600 mm 0 to 1000 mm 12.2 µm 13.3 µm Using Caliper Checker, Slip Gauge Block & 2. Depth Caliper $ (Vernier/Dial/Digital)
More informationAstm E83. Astm E83
We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with astm e83. To get started
More informationPROMPT ENGINEERING P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR
This is to attest that PROMPT ENGINEERING P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR Calibration Laboratory CL-165 has met the requirements of AC204, IAS Accreditation
More informationStainless Steel Precision Weights and Weight Sets
Stainless Steel Precision Weights and Weight Sets Our finest weights for your finest weighing measuring up: Troemner s Calibration & Certification Laboratories have been accredited by NIST/NVLAP and its
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CRYSTAL ENGINEERING CORPORATION, AN AMETEK INC. COMPANY 708 Fiero Lane, Suite 9 San Luis Obispo, CA 93401 Janine White Phone: 805 595
More informationQA Tech (A Division of GMP Technical Solutions Pvt. Ltd.), L-73, Verna Industrial Estate, Verna Salcette, Goa
Last Amended on - Page 1 of 5 I. DIMENSION 1. CALIPER $ L.C. :-10µm Φ 0 to 300 mm 13 µm Using Caliper Checker; & T.C. Gauge Block Set by Comparison L.C. :- 20µm 0 to 1000 mm 22 µm Using Caliper Checker;
More informationOIML Weights & Weight Sets
OIML Weights & s PRECISE WEIGHTS FOR YOUR MOST PRECISE WORK Troemner, an ISO 9001 registered company, is the world s leading supplier of precision weights, weight sets, mass standards and associated calibration/certification
More informationANALYTICAL STUDY ON THE UNCERTAINTY OF LOAD CELLS CALIBRATED WITH DEADWEIGHT-FORCE-STANDARD MACHINE AND FORCE-COMPARATOR MACHINE
ANALYTICAL STUDY ON THE UNCERTAINTY OF LOAD CELLS CALIBRATED WITH DEADWEIGHT-FORCE-STANDARD MACHINE AND FORCE-COMPARATOR MACHINE Sumet Heamawatanachai 1,*, Kittipong Chaemthet 1, Noppadon Sumyong 1, and
More informationShawal CGC Calibration Profile
Shawal CGC Calibration Profile Phone Number: +93 700021925, +93 748468800, +93 779015120 TABLE OF CONTENTS 1.0. INTRODUCTION 2.0 COMPANY STRUCTURE 3.0 CALIBRATION & EQUIPMENT & REPAIR SERVICES 4.0 COMPETITIVE
More informationRev /07/2015 CATALOGUE - CALIBRATION SERVICES 1
Rev. 02 07/07/2015 CATALOGUE - CALIBRATION SERVICES 1 OVER 100 ITEMS We are proud to present to you our new catalogue for 2015. In the following pages we present more than 100 instrument types, which we
More informationFlow Research and Test Center
SALES BULLETIN Flow Research and Test Center CREATING RESOURCE TECHNOLOGY FOR TODAY AND TOMORROW The key to FMC Technologies success has been its ability to provide the latest technology in products and
More informationDiscipline Mechanical Calibration Issue Date Certificate Number C-0208 Valid Until Last Amended on
Last Amended on 12.08.2016 Page 1 of 7 I. DIMENSION (Basic Measuring, Gauge etc.) 1. CALIPER $ (Vernier / Dial / Digital) L.C.: 10 µm ф L.C.: 50 µm ф Upto 600mm 13 m Using Gauge Block Set Grade 0 (Carbide);
More informationQ-Tech Engineering Services, S-134, C/o, Precision Engineering Works, MIDC, Bhosari, Pune, Maharashtra
Last Amended on 24.05.2015 Page 1 of 5 I. DIMENSION 1. EXTERNAL MICROMETER $ L.C. 1 µm Φ >100 mm to 300 mm 1.4 µm 3.0 µm Using Slip Gauge Blocks Gr '0' / Long Slip Gauges, by Comparison 2. DEPTH MICROMETER
More informationCentral Mechanical Engineering Research Institute, Mahatma Gandhi Avenue, Durgapur, West Bengal
Last Amended on 23.09.2014 Page 1 of 9 I. DIMENSION 1. GAUGE BLOCKS $ 0.5 mm to 25 mm 25 mm to 50 mm 50 mm to 75 mm 75 mm to 100 mm 2. LENGTH BAR $ Upto 300 mm 300 mm to 600 mm 300 mm to 1000 mm 0.11µm
More informationCertificate of Accreditation
ISO/IEC 17025:2005 Certificate of Accreditation Certificate Number L2195 Exova, Inc. Anaheim 3883 East Eagle Drive Anaheim CA 92807 has met the requirements set forth in L-A-B s policies and procedures,
More informationMetrology Laboratory, CMTI, Central Manufacturing Technology Institute, Tumkur Road, Bangalore, Karnataka Accreditation Standard ISO/IEC 17025: 2005
aboratory Metrology aboratory, CMTI, Central Manufacturing Technology ast Amended on 22.09.2016 Page 1 of 15 I. DIMENSION (Basic Measuring, Gauge etc.,) 1. ANGE GAUGE BOCKS $ 0 to 90 2.8 arc sec Using
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-19459-8 SOUTH AFRICAN NATIONAL STANDARD Verification standards for the verification of volume-measuring instruments, including commercial standards of volume Published by Standards South
More information... CALIBRATION SERVICES PRICELIST. M&B Calibr. Accredited calibration company. No according to ČSN EN ISO/IEC
M&B Calibr... CALIBRATION SERVICES PRICELIST Accredited calibration company No. 2301 according to ČSN EN ISO/IEC 17025. Experience since 1991 Guaranteed quality Professional attitude www.mbcalibr.cz You
More informationMass Comparators Advanced Radwag solutions for traceability of measurement
Mass Comparators Advanced Radwag solutions for traceability of measurement Automatic Mass Comparators COMPARISON OF 1 mg 1000 g WEIGHTS OF CLASS E1, E2, F1, F2, M1 AND M2 Automatic Mass Comparators UMA
More informationRef:CL/Mech./ Cal /BID-01(13-14) Date: 10 July 2013
Ref:CL/Mech./ Cal /BID-0(3-4) Date: 0 July 203 SUBJECT: Procurement of Calibration Services for the Equipments in Central Laboratory (Mechanical). Dear Sirs, Technical & Commercial Bids are invited for
More informationInspection Institute of Weights and Measures
Tokyo Metropolitan Government Inspection Institute of Weights and Measures Operations of Inspection Institute of Weights and Measures ~ Verification and Inspection of Verification Standards Verification
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 APPLIED TECHNICAL SERVICES, INC. 1049 Triad Court Marietta, GA 30062 Cathy Mansfield Phone 770 423 1400 cmansfield@atslab.com MECHANICAL Valid To: June 30,
More informationUNIVERSAL CALIBRATING MACHINES
FIGURE 1-100,000 lbf Morehouse Universal Calibrating Machine using a Morehouse Proving Ring to calibrate a Load Cell in compression. An optional Auxiliary Screw Pump is attached to Machine s upper platen.
More informationTorsion testing machine
WTT Series Metal Wire Torsion Tester Application: WTT Series Metal Wire Torsion Tester is mainly used to test the plasticity of metal wires and ropes under torsion condition. Surface flaws of steel wires
More informationCal-Tech Calibration Services Pvt. Ltd., Flat No.8, Avadhut Heights, Anand Nagar, Sinhgad Road, Pune, Maharashtra
Last Amended on - Page 1 of 5 I. DIMENSION 1. CALIPER $ L.C. :-10 µm 0 to 300 mm 12.0 µm Using Caliper Checker; Gauge 0 to 1000 mm 12.0 µm Block Set L.C. :-20 µm 0 to 600 mm 16.0 µm 0 to 1000 mm 20.0 µm
More informationA PORTABLE SYSTEM FOR THE CALIBRATIONOF TRANSDUCERS AND TORQUE WRENCHES: THE CALIBRATION BELL
XIX IMEKO World Congress Fundamental and Applied Metrology September 6, 009, Lisbon, Portugal A PORTABLE SYSTEM FOR THE CALIBRATIONOF TRANSDUCERS AND TORQUE WRENCHES: THE CALIBRATION BELL Carlo Ferrero,
More informationHeight Master Page 345. Check Master Page 349. Calibration Tools Page 354
Calibration Instruments Height Master Page 345 Check Master Page 349 Calibration Tools Page 354 344 Digital Height Master Functions ZERO/ABS DATA/HOLD Auto Power OFF after 20 min. non use Low voltage alarm
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17435-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 30.09.2016 to 08.12.2018 Holder of certificate: k3works
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Charter Coating Service (2000) Ltd. Suite
More informationForceBoard - Desktop friction, wear, tensile and fatigue testing system
ForceBoard.com ForceBoard - Desktop friction, wear, tensile and fatigue testing system Made in Sweden by Industrial Dynamics AB Hardware Note: If you have special requests on the hardware we can solve
More informationDiscipline Mechanical Calibration Issue Date Certificate Number C-0393 Valid Until Last Amended on - Page 1 of 6
Last Amended on - Page 1 of 6 I. DIMENSION 1. Vernier Caliper (Digital/ Dial/ Scale) $ L.C.: 0.01 mm 0 to 150 mm 7.7 µm Using Caliper Checker 0 to 200 mm 8.1 µm 0 to 300 mm 9.3 µm 0 to 600 mm 13.9 µm 2.
More informationISO 376 INTERNATIONAL STANDARD. Metallic materials Calibration of force-proving instruments used for the verification of uniaxial testing machines
INTERNATIONAL STANDARD ISO 376 Third edition 2004-11-01 Metallic materials Calibration of force-proving instruments used for the verification of uniaxial testing machines Matériaux métalliques Étalonnage
More informationVerifying the accuracy of involute gear measuring machines R.C. Frazer and J. Hu Design Unit, Stephenson Building, University ofnewcastle upon Tyne,
Verifying the accuracy of involute gear measuring machines R.C. Frazer and J. Hu Design Unit, Stephenson Building, University ofnewcastle upon Tyne, Abstract This paper describes the most common methods
More informationPull-Off Adhesion Tester
PosiTest Measures adhesion of coatings to metal, wood, concrete and other substrates revolutionary self-alignment feature and pull rate indicator. Available in 2 models... Manual or Automatic PosiTest
More information