1 Last Amended on Page 1 of 7 I. MASS 1. Weights $ (Conventional Mass) 1 mg mg Using Weights of 2 mg mg accuracy Class F1 and 5 mg mg 10 mg mg 20 mg mg 50 mg mg 100 mg mg 200 mg mg 500 mg mg 1 g 0.03 mg 2 g 0.03 mg 5 g 0.03 mg 10 g 0.03 mg 20g 0.03 mg 50 g 0.10 mg 100 g 0.11 mg 200g 0.16 mg Using Weights of accuracy Class E2 and 500 g 8.3 mg Using Weights of accuracy Class F1 and
2 Last Amended on Page 2 of 7 1 kg 10.3 mg Using Weights of 2 kg 10.3 mg accuracy Class M1 and 5 kg 15.4 mg 10 kg 133 mg 20 kg 1.1 g 50 kg 2.4 g 2. Weighing Machine # Readability 0.01 mg Readability = 0.1 mg (0 to 200) g 0.04 mg 0.16 mg Using Weights of E2 class Procedure based on OIML R-76 (2006) Readability 10 mg (0 to 1000)g 0.02 mg Readability =10 mg (0 to 10) kg 0.13 g Readability = 100 mg 0.3 g Readability = 1g 1.5 g Readability = 1g (0 to 100) kg 2 g Readability = 10 g 15 g Using Weights of class F1 and M1 Procedure based on OIML R-76 (2006) II. VOLUME 1. Micropipette /Pipette $ 2 µl to 100 µl 0.1 µl Using Standard weights >(100 to 1000) µl 0.2 µl (E2,F1 and M1 class), >( 1 to 10) ml 0.5 µl Precision Balances, > (10l to 100) ml 0.6 µl Double distilled water of 2. Burette $ (1 to 10) ml 0.1 µl known density by Gravimetric method >(10 to 100) ml 0.2 µl based on ISO 4787 (2010) 3. Volumetric Flasks $ (10 to 100) ml 10 µl >(100 to 1000) ml 15 µl >(1000 to 5000) ml 21 µl
3 Last Amended on Page 3 of 7 4. Measuring Cylinder / Measuring Container/ Cane $ III. PRESSURE & VACUUM (1 to 100) ml 0.1 µl Using Standard weights >(100 to 1000) ml 0.5 µl (E2,F1 and M1 class), >(1000 to 5000) ml 0.2 ml Precision Balances, >(5000 to 20000) ml 0.3 ml Double distilled water of known density by Gravimetric method based on ISO 4787 (2010) 1. Pressure (Pneumatic) Digital /Analog Gauges, Transmitters, Switches # 0 to 2 bar bar to 0 bar bar bar Using Digital Pressure /Vacuum Gauges/ hand held pump by Comparison Method 2. Pressure (Hydraulic) Digital /Analog Gauges, Transmitters, Switches # 0 to 30 kg/cm 2 0 to 700 bar kg/cm bar Using Digital Pressure Gauges/ hydraulic pump by Comparison Method IV. ACCOUSTICS 1. Sound Level Meter $ (Weighting A/C) V. ACCELERATION & SPEED 1 khz 94 db to 114 db 0.7 db Using Sound Level Calibrator 1. Tachometer $ -Non contact type - Contact type 60 rpm to 5000 rpm > 5000 rpm to rpm 60 rpm to 5000 rpm >5000 rpm to 10000rpm 1% 0.06% 1.15% 0.1% Using Digital non contact Tachometer
4 Last Amended on Page 4 of 7 VI. DIMENSION $ 1. Caliper (Vernier / Dial / Digital) L.C.10µm ф L.C.10µm ф Up to 600mm Up to 1000mm 17 m 21 m Using Gauge Block Set / Caliper Checker / Ext. Micrometer by IS Depth Vernier Caliper (Vernier / Dial / Digital) L.C. 20µm Up to 300mm 17 m Using Gauge Block Set / Depth micro Checker by IS Height Gauge (Vernier / Dial / Digital) L.C. 10µm ф Up to 600mm 16 m Using Gauge Block Set / Caliper Checker by IS External Micrometer L.C.1µm ф L.C.1µm ф Up to 100mm 100mm to 300mm 2.2 m 2.7 m Using Gauge Block Set / Mic Check Set by IS 2967
5 Last Amended on Page 5 of 7 5. Depth Micrometer L.C. 1µm ф Up to 300mm 8.3 m Using Gauge Block Set / Mic Check Set by IS Dial Gauge (Plunger / Digital Type) L.C. 1.0µm 0 to 25mm 3.9 m Using Dial Gauge Tester by Comparison Method as per IS Dial Gauge (Lever Type) L.C. 1.0µm L.C. 10.0µm 0 to 1.4mm 0 to 2mm 3.9 m 6.8 m Using Dial Gauge Tester by Comparison Method as per IS Bore Gaugewith Dial For Transmission Accuracy L.C.1.0µm 0 to 1mm 3.83 m Using Dial Gauge Tester by Comparison Method 9. Feeler Gauge /Foils 0 to 1mm 5 m Using Digital Micrometer by Comparison Method as per IS 3179
6 Last Amended on Page 6 of Bevel Protractor L.C. 5 min. 11. V Block Symmetricity 0 to 180 to Using Angle Gauge Block Set by Comparison Method as per IS mm 8.3 m Using Dial Gauge, Surface plate Mandrel by IS Snap Gauge 3mm to 100mm 4 m Using Gauge Block by IS Measuring Scale /Tape 150 mm to 30m 566 m Using Tape and Scale calibrator by Comparison Method VII.TORQUE 1. Torque Wrench $ (2 to 20) Nm (20 to 100) Nm (100 to 500) Nm 0.50% 1.37% 0.90% Torque Wrench calibration system by Comparison Method as per CCL/CM/TQ ( ISO6789 : 2003)
7 Last Amended on Page 7 of 7 VIII. FORCE 1. UTM Machines 1000 N to 45 kn Compression 1000 N to 45 kn Tension 0.66% 0.66% Using Class 0 load cell of Interface as per IS 1828 ( Part-1) :2005 * Measurement Capability is expressed as an uncertainty ( ) at a confidence probability of 95% ** Relative accuracy error has not been considered for CMC estimation. ф Laboratory can also calibrate instruments/devices of coarser resolution / least count within the accredited range using same reference standard/ master equipment under the scope of accreditation. $ Only in Permanent Laboratory Only for Site Calibration # The laboratory is also capable for site calibration however, the uncertainty at site depends on the prevailing actual environmental conditions and master equipment used.
Discipline Mechanical Calibration Issue Date Certificate Number C-0208 Valid Until Last Amended on
Last Amended on 12.08.2016 Page 1 of 7 I. DIMENSION (Basic Measuring, Gauge etc.) 1. CALIPER $ (Vernier / Dial / Digital) L.C.: 10 µm ф L.C.: 50 µm ф Upto 600mm 13 m Using Gauge Block Set Grade 0 (Carbide);
More informationInstitute for Design of Electrical Measuring Instruments, Swatantryaveer Tatya Tope Marg, Chunabhatti, Sion, Mumbai, Maharashtra
Last Amended on 02.09.2014 Page 1 of 10 I. DIMENSION 1 Calipers $ Up to 600 mm 10.4 µm Using Caliper Checker by Up to 1000 mm 13.2 µm Using Long Slip Gauge by 2 Height Gauges $ Up to 600 mm 12.8 µm Using
More informationAccurate Labs, 311, 312 Govinda Complex, GIDC Char Rasta, Vapi, Valsad, Gujarat. Discipline Mechanical Calibration Issue Date
Last Amended on - Page 1 of 9 I. DIMENSION 1. CALIPER $ Vernier L.C. 0.01mm 7.5 µm 9.0 µm Using Caliper Checker & Slip Gauges L.C. 0.05mm 29.5 µm 30.0 µm Dial / Electronic L.C. 0.02mm 12.5 µm 13.5 µm 2.
More informationAlcalab Private Limited, 3rd Floor, Ashiana Trade Centre, Adityapur, Jamshedpur, Jharkhand. Discipline Mechanical Calibration Issue Date
Last Amended on - Page 1 of 11 I. DIMENSIONS 1. SLIP 0.5 mm to 25 mm 0.25 μm Using Slip Gauge (K-Grade) & > 25 mm to 50 mm 0.34 μm Double Probe Comparator > 50 mm to 75 mm 0.46 μm > 75 mm to 100 mm 0.58
More informationHi-Tech Calibration, 307, 3rd Floor, Govinda Complex, Char Rasta, Vapi, Gujarat. Discipline Mechanical Calibration Issue Date
Last Amended on 18.01.2016 Page 1 of 7 I. DIMENSIONS 1. CALIPER $ (Vernier, Dial, Electronics) L.C.0.01 mm up to 1000mm 24 µm Using Caliper Checker / L.C.0.02 mm up to 600mm 19 µm Length Bars /Slip Gauges
More informationICL Calibration And Testing Services, SCO - 37, Ground Floor, Sector-12, Panchkula, Haryana. Discipline Mechanical Calibration Issue Date
Last Amended on 09.12.2016 Page 1 of 8 I. DIMENSION (Basic Measuring, Gauge etc.) 1 LENGTH GAUGE/SETTING ROD $ Up to 100 mm >100 mm to 500 mm 1.5 µm 7.20 µm Using ULM, Gauge Block grade- 0 & Electronic
More informationDiscipline Mechanical Calibration Issue Date Certificate Number C-0752 Valid Until Last Amended on - Page 1 of 6
Last Amended on - Page 1 of 6 I DIMENSION 1. Caliper $ (Vernier/Dial/Digital) LC : 0.01mm 0 to 600 mm 0 to 1000 mm 12.2 µm 13.3 µm Using Caliper Checker, Slip Gauge Block & 2. Depth Caliper $ (Vernier/Dial/Digital)
More informationA.A. Calibration Pvt. Ltd., 13-C/18, Vasundhara Haat, Vasundhara, Ghaziabad, Uttar Pradesh. Discipline Mechanical Calibration Issue Date
Last Amended on 02.09.2014 Page 1 of 10 I. DIMENSION 1. VERNIER CALIPER $ L.C. 0.01mm 0 to 300 mm 0 to 600 mm 0 to 1000 mm 8 µm 14 µm 16 µm, Slip Gauge Accessories, Gauge Block L.C. 0.02 mm 0 to 1500 mm
More informationQ-Tech Engineering Services, S-134, C/o, Precision Engineering Works, MIDC, Bhosari, Pune, Maharashtra
Last Amended on 24.05.2015 Page 1 of 5 I. DIMENSION 1. EXTERNAL MICROMETER $ L.C. 1 µm Φ >100 mm to 300 mm 1.4 µm 3.0 µm Using Slip Gauge Blocks Gr '0' / Long Slip Gauges, by Comparison 2. DEPTH MICROMETER
More informationAutocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra
Last Amended on - Page 1 of 5 I. DIMENSION 1. CALIPER (Vernier/Dial/Digital) L. C. : 10µm Φ 0 to 600 mm 16 µm Using Caliper Checker & External Micrometer by 2. DEPTH GAUGE (Vernier/Dial/ Digital) L. C.
More informationAccurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date
Last Amended on 11.11.2014 Page 1 of 6 I. DIMENSION 1. Dial/ Digital Vernier Caliper $ L.C.: 0.01mm Φ 0 to 200 mm 7.5 µm Using Slip Gauge Set & L.C.: 0.01mm Φ 0 to 300 mm 12.17 µm Using Slip Gauges & Caliper
More informationQA Tech (A Division of GMP Technical Solutions Pvt. Ltd.), L-73, Verna Industrial Estate, Verna Salcette, Goa
Last Amended on - Page 1 of 5 I. DIMENSION 1. CALIPER $ L.C. :-10µm Φ 0 to 300 mm 13 µm Using Caliper Checker; & T.C. Gauge Block Set by Comparison L.C. :- 20µm 0 to 1000 mm 22 µm Using Caliper Checker;
More informationCentral Mechanical Engineering Research Institute, Mahatma Gandhi Avenue, Durgapur, West Bengal
Last Amended on 23.09.2014 Page 1 of 9 I. DIMENSION 1. GAUGE BLOCKS $ 0.5 mm to 25 mm 25 mm to 50 mm 50 mm to 75 mm 75 mm to 100 mm 2. LENGTH BAR $ Upto 300 mm 300 mm to 600 mm 300 mm to 1000 mm 0.11µm
More informationCal-Tech Calibration Services Pvt. Ltd., Flat No.8, Avadhut Heights, Anand Nagar, Sinhgad Road, Pune, Maharashtra
Last Amended on - Page 1 of 5 I. DIMENSION 1. CALIPER $ L.C. :-10 µm 0 to 300 mm 12.0 µm Using Caliper Checker; Gauge 0 to 1000 mm 12.0 µm Block Set L.C. :-20 µm 0 to 600 mm 16.0 µm 0 to 1000 mm 20.0 µm
More informationDiscipline Mechanical Calibration Issue Date Certificate Number C-0393 Valid Until Last Amended on - Page 1 of 6
Last Amended on - Page 1 of 6 I. DIMENSION 1. Vernier Caliper (Digital/ Dial/ Scale) $ L.C.: 0.01 mm 0 to 150 mm 7.7 µm Using Caliper Checker 0 to 200 mm 8.1 µm 0 to 300 mm 9.3 µm 0 to 600 mm 13.9 µm 2.
More informationCaliber Gauges & Instruments Laboratory, S. No. 14/1, Dattadigamber Soc. B, Warje Jakat Naka, Pune, Maharashtra
Last Amended on - Page 1 of 10 I. DIMENSION (Basic Measuring, Gauge etc.) 1. PLAIN PLUG / WIDTH/ DEPTH/ Upto 100 mm 1.9 µm Using Electronic FLUSH PIN GAUGE DIAMETER /WIDTH / DEPTH $ 100 mm to 300 mm 3.8
More informationShriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka
Certificate Number CC-2083 (in lieu of C-0216, C-0304, C-1497) Page 1 of 7 ELECTRO-TECHNICAL CALIBRATION I. MEASURE 1. Time $ 5 sec to 9900 sec 0.12 sec to 5.8 sec Using Digital Time Totalizer (Digital
More informationDiscipline Mechanical Calibration Issue Date Certificate Number C-0751 Valid Until Last Amended on
Last Amended on 10.03.2016 Page 1 of 5 I. DIMENSION 1. Vernier caliper $ 0 to 300 mm/0.01 mm ± 12.0 µm Using Caliper Checker 0 to 300 mm/0.02 mm ± 16.1 µm Using Caliper Checker 0 to 600 mm/0.01 mm ± 14.0
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that SP Metrology System Thailand Co., LTD 88/115
More informationPage : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *
Metrix Precision Pte Ltd Certificate No. : LA-2014-0581-C No. 23 Tagore Lane #02-03/04 Tagore 23 Warehouse Issue No. : 2 Singapore 787601 Date : 29 July 2016 FIELD OF TESTING : Calibration and Measurement
More informationSchedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.
Page: 1 of 9 LABORATORY LOCATION: (PERMANENT LABORATORY) PPCALIBRATION SERVICES SDN. BHD. NO. 15, MEDAN BUKIT EMAS PUSAT PERNIAGAAN BUKIT EMAS 14000 BUKIT MERTAJAM, PULAU PINANG MALAYSIA This laboratory
More informationHellenic Accreditation System. Annex F2/17 to the Certificate No SCOPE of ACCREDITATION
Hellenic Accreditation System Annex F2/17 to the Certificate No. 263-5 SCOPE of ACCREDITATION of the Testing & Calibration Laboratory of LINK LAB LTD for the performance of calibrations Measurand / Spectrophotometric
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALDINGER COMPANY 1440 Prudential Drive Dallas, TX 75235 Timothy R. Detten Phone: 214 638 1808 CALIBRATION Valid To: July 31, 2018 Certificate
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Monterrey, Nuevo León, 64920 (Hereinafter called the
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Torreón, Coahuila, México C.P. 27019 (Hereinafter
More informationMetrology Laboratory, CMTI, Central Manufacturing Technology Institute, Tumkur Road, Bangalore, Karnataka Accreditation Standard ISO/IEC 17025: 2005
aboratory Metrology aboratory, CMTI, Central Manufacturing Technology ast Amended on 22.09.2016 Page 1 of 15 I. DIMENSION (Basic Measuring, Gauge etc.,) 1. ANGE GAUGE BOCKS $ 0 to 90 2.8 arc sec Using
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 RIVERVIEW CALIBRATION SERVICES, LTD 5706 Veto Road Belpre, OH 45714 J. Michael Pennell Phone: 740 678 8625 CALIBRATION Valid To: July
More informationWelcome to Garber C O R P O R AT E O V E R V I E W
CORPORATE OVERVIEW Garber Metrology is one of the only companies in the Mid-Atlantic Region that combines full service weighing solutions, a wide range of calibration /metrology services and a broad scope
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 EMPIRE SCALE CORPORATION d.b.a. PRECISION SCALE & BALANCE d.b.a. EMPIRE SCALE & BALANCE 140 Rotech Drive Lancaster, NY 14086 Margery
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 NORTHERN BALANCE AND SCALE, INC. 9556 W. Bloomington Freeway Bloomington, MN 55431 Joey Kaluser Phone: 952 881 7716 CALIBRATION Valid
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Garber Metrology Weighing Solutions & Precision
More informationAnnex to the Accreditation Certificate D-K according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-K-15102-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 05.07.2017 to 04.07.2022 Date of issue: 05.07.2017
More informationSchedule. 300 mm to 600 mm 600 mm to 1000 mm inch to 12 inch
LABORATORY LOCATION: (PERMANENT LABORATORY) MITUTOYO (M) SDN. BHD. MAH SING INTEGRATED INDUSTRIAL PARK BANDAR PINGGIRAN SUBANG 4, JALAN UTARID U5/14, SECTION U5 40150 SHAH ALAM SELANGOR, MALAYSIA Page:
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
Chamber Commerce: 06073326 Location(s) where activities are performed under accreditation ad Office Smaragdstraat 7 7554 TD ngelo OV The Netherlands Location Abbreviation/ location Smaragdstraat 7 7554
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationRef:CL/Mech./ Cal /BID-01(13-14) Date: 10 July 2013
Ref:CL/Mech./ Cal /BID-0(3-4) Date: 0 July 203 SUBJECT: Procurement of Calibration Services for the Equipments in Central Laboratory (Mechanical). Dear Sirs, Technical & Commercial Bids are invited for
More informationRev /07/2015 CATALOGUE - CALIBRATION SERVICES 1
Rev. 02 07/07/2015 CATALOGUE - CALIBRATION SERVICES 1 OVER 100 ITEMS We are proud to present to you our new catalogue for 2015. In the following pages we present more than 100 instrument types, which we
More informationCALIBRATION SYSTEM CERTIFICATE
CALIBRATION SYSTEM CERTIFICATE With respect to products (measuring instruments and testing instruments), we hereby certify that we have established our calibration system traceable to the national (international)
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 QUALITY CONTROL SERVICES, INC. 2340 SE 11 th Avenue Portland, OR 97214 George Cahill Phone: 503 236 2712 CALIBRATION Valid To: September
More informationScope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX Gavin Lewis
Scope of Accreditation For Global Instrumentation Services, LLC 523 N. Sam Houston Parkway E, Suite 230 Houston, TX 77060 Gavin Lewis 832-428-2737 In recognition of a successful assessment to ISO/IEC 17025:2005
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationTransferpette. Testing Instructions (SOP) 1. Introduction. May 2009
Transferpette Testing Instructions (SOP) May 2009 1. Introduction The standards DIN EN ISO 8655 describe both the design and the testing of the piston operated pipette Transferpette. The following Testing
More informationTEST AND CALIBRATION SERVICES Ensuring quality and reliability.
> TEST AND CALIBRATION SERVICES Ensuring quality and reliability www.thalesgroup.com.au TEST AND CALIBRATION SERVICES ENSURING QUALITY AND RELIABILITY Introduction Thales Australia s Test and Calibration
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORYACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2017. Data Weighing Systems 255 Mittel Drive Wood Dale, IL Steven A. Thomas CALIBRATION
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 Data Weighing Systems 255 Mittel Drive Wood Dale, IL 60191 Steven A. Thomas 800-397-6301 CALIBRATION Valid to: September 22, 2019 Certificate Number: L1114-1
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Schedule of ccreditation United Kingdom ccreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK ccredited to Laboratory locations: Unit 9 G B Quality ssurance (Consultants)
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Schedule of ccreditation United Kingdom ccreditation Service ccredited to Division of Cromwell Tools Ltd Services Block 65 Chartwell Drive Wigston Leicester LE18 2FS Contact: Mr T still Tel: +44 (0)116-2572396
More informationTRI-STATE INSTRUMENT SVC, INC
CALIBRATION RATE POLICY AND PRICING 2017 Typically, compliance with ISO-900x and TS 16949 specifications require LONG FORM calibration reports in the following formats. Format #1 -- Before Adjustment or
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 METTLER TOLEDO (INDUSTRIAL) 1900 Polaris Parkway Columbus, OH 43240 Frank Gardone Phone: 412 213 2263 CALIBRATION Valid To: April 30,
More informationTransferpette. Testing Instructions (SOP) 1. Introduction. October 2013
Transferpette Testing Instructions (SOP) October 2013 1. Introduction The standards DIN EN ISO 8655 describe both the design and the testing of the piston operated pipette Transferpette. The following
More informationCarl Stuart Ltd. Tallaght Business Park, Whitestown, Dublin 24. Calibration Laboratory Registration number: 270C
Tallaght Business Park, Whitestown, Dublin 24 Calibration Laboratory Registration number: 270C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule bearing
More informationVITLAB Dispenser. Standard Operating Procedure (SOP)
VITLAB Dispenser Standard Operating Procedure (SOP) VITLAB GmbH Linus-Pauling-Str. 63762 Grossostheim Germany tel: +49 6026 97799-0 fax: +49 6026 97799-30 info@vitlab.com www.vitlab.com Table of contents.
More informationHeight Master Page 345. Check Master Page 349. Calibration Tools Page 354
Calibration Instruments Height Master Page 345 Check Master Page 349 Calibration Tools Page 354 344 Digital Height Master Functions ZERO/ABS DATA/HOLD Auto Power OFF after 20 min. non use Low voltage alarm
More informationPrice List. Calibration Fee
3/4-5 Moo 3, Klong 5, Klong Luang, Pathumthani, 110, Thailand Tel. +66 577 5100 (Please contact : Customer Service Section Ext. 3101, 310) Fax. +66 577 3659 E-mail : cs@nimt.or.th Website : http://www.nimt.or.th
More informationUGANDA NATIONAL BUREAU OF STANDARDS NATIONAL METROLOGY LABORATORY
CALIBRATION CHARGES Page 1 of 5 In the derivation of calibration charges a number of factors have been taken into consideration. These include the following; 1. Personnel Salaries and man-hours for calibration
More informationPROMPT ENGINEERING P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR
This is to attest that PROMPT ENGINEERING P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR Calibration Laboratory CL-165 has met the requirements of AC204, IAS Accreditation
More informationCalibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5
National Research Council Conseil national de recherches Canada Canada Measurement Standards and Science Science des mesures et étalons Calibration Laboratory Assessment Service CLAS Certificate Number
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CAL-RITE CORPORATION 1665 Quincy Avenue, Suite 103 Naperville, IL 60540 Michael Crosby Phone: 630 355 1522 CALIBRATION Valid To: December
More informationMeasuring. Affordable. Effective. Instruments
Measuring Effective Affordable Instruments 2 Electronic Calipers 00534002 00534003 00534020 n Stainless steel frame n Thumb wheel for rapid setting n Direct Metric/Inch conversion n Accuracy to 0,02 mm
More informationSelecting Weights and Certificates
11 Weight Selection There are several shapes, designs and sizes available to meet your needs. Selecting the proper weight for your application can be confusing given the number of weight classes, designs,
More information+91-8048600379 Rampura Tools http://www.rampuratools.in/ We are one of the leading distributor, suppliers and traders of Measuring Instrument. Owing to their accurate measurement, sturdy construction,
More informationAccredited Laboratory
Accredited Laboratory A2LA has accredited CAL-RITE CORPORATION Naperville, IL for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
Schedule of ccreditation United Kingdom ccreditation Service Issue No: 028 Issue date: 10 pril 2018 ccredited to 6 Banner Park Wickmans Drive Coventry CV4 9X Contact: Keith rnold Tel: +44 (0)2476 426 316/317
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane
More informationSmall Tool Instruments and Data Management
Small Tool Instruments and Data Management Gauge Blocks Pages 302 311 Calibration instruments Pages 312 319 301 Basic information on gauge blocks Characteristics of Mitutoyo gauge blocks: Mitutoyo, at
More informationTitrette and Digital Burette
Titrette and Digital Burette (all models) Testing Instructions (SOP) May 2009 1. Introduction The standard ISO DIS 8655 describes both the design and the testing of bottle-top burette. The following Testing
More informationTopPette Mechanical Pipettes
TopPette Mechanical Pipettes Features for TopPette - Lightweight, ergonomic, low force design - Digital display clearly reads volume setting - The pipettes cover volume range of 0.1μl to 10ml - Easy to
More information+91-8048718949 Bearing & Tools Centre http://www.measuringtestinginstrument.com/ We are a renowned dealer and supplier of a wide assortment of precision engineered testing and measuring equipment. Our
More informationDispensette. Testing Instructions (SOP) 1. Introduction. May 2009
Dispensette Testing Instructions (SOP) May 2009 1. Introduction The standard ISO DIS 8655 describes both the design and the testing of the bottle-top dispenser. The following Testing Instructions describe
More informationFlow Research and Test Center. Creating resource technology for today and tomorrow.
Flow Research and Test Center Creating resource technology for today and tomorrow. "The Measurement Solutions Flow Research and Test Center in Erie is certainly one of the gems of our corporation s technological
More informationACCREDITATION FACILITY AUDIT CHECKLIST
ACCREDITATION FACILITY AUDIT CHECKLIST Institution Name: Date: Designated Trade: Marine and Outdoor Power Equipment Technician AC #: Contact: Location: Course Duration: of weeks: of hours total: of hours
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Mexical Metrología, S.A. de C.V. Tecnología de Materiales,
More informationRe: Extension for ISO/IEC 17025: 2005 accreditation Certificates #ACT-1997, ACT , ACT & AT
October 17, 2017 VIA EMAIL Link Engineering Company Jim Villella 401 Southfield Road Dearborn, MI 48120 Re: Extension for ISO/IEC 17025: 2005 accreditation Certificates #ACT-1997, ACT-1997.01, ACT-1997.02
More informationPage 1 of 5. United Testing Systems, Inc S. Acacia Avenue Fullerton, CA William Warner, Quality Manager
IAS Accreditation Number Accredited Entity Address CL-128 1375 S. Acacia Avenue Fullerton, CA 92831 William Warner, Quality Manager Contact Name Telephone +1 (714) 638-2322 Effective Date of Scope July
More informationREQUEST FOR QUOTATION
REQUEST FOR QUOTATION TO, GAIL WEBSITE VENDOR India Vendor Code - 101019938 RFQ No.: GAIL/08/RJ19140/3300025749/ Dated : 23.07.2008 Kind Attn : Mr/Ms Dear Sir/Madam, GAIL (India) Ltd. invites you to submit
More informationIEC SYSTEM FOR CONFORMITY TESTING AND COMMITTEE OF TESTING LABORATORIES CERTIFICATION OF ELECTRICAL EQUIPMENT
IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL EQUIPMENT COMMITTEE OF TESTING LABOATOIES =equired by Lab S=May be subcontracted TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING Power
More informationGENERAL LABORATORY EQUIPMENTS
CONTENTS CONTENTS GENERAL LABORATORY EQUIPMENTS Laboratory Glassware Length Measurement Load R ng & Load Cell L neer Potant ometr c Transducor Data Logger D g tal & D al Gauges 115-117 118 119 119 120
More informationDepartment of Mechanical Engineering ME6513 - METROLOGY AND MEASUREMENT LAB LABORATORY MANUAL Name Register No. Branch Year & Semester : : : : 1 CONTENTS S.NO. DATE EXPERIMENT NAME PAGE NO. 1 Calibration
More information6-2. Traceability. (1) Traceability system. Chapter 6-2
Chapter 6-2 6-2. Traceability (1) Traceability system Torque can be resolved into length by the force. As the units of length and force are approved by official calibration laboratory respectively, the
More informationSPECIFICATION SHEET Pulse tool / Impact Wrench Testing System MODEL : IWT-101
Applications Calibration of Impact tools Calibration oil pulse tools And also any type of manual wrenches Importance of Torque tool calibration: Controlling torque of a torque tool is important for companies
More informationSWISS MADE EXECUTIVE. Series 360 ES
SWISS MADE EXECUTIVE Series Semi-micro Analytical Precision EXECUTIVE Precisa With the 360 series, Precisa is setting new standards in the demanding area of high-end laboratory balances: innovative, hightech
More informationShawal CGC Calibration Profile
Shawal CGC Calibration Profile Phone Number: +93 700021925, +93 748468800, +93 779015120 TABLE OF CONTENTS 1.0. INTRODUCTION 2.0 COMPANY STRUCTURE 3.0 CALIBRATION & EQUIPMENT & REPAIR SERVICES 4.0 COMPETITIVE
More informationUK Weighing Federation Technical Articles
3.4 WEIGHTS Introduction It normally starts with a phone call from a potential customer, I need some weights. As with any enquiry for any piece of weighing equipment, the first and most important point
More informationANAUM INTERNATIONAL ELECTRONICS LLC. Test and Measurement Calibration Services Test Bench.
ANAUM INTERNATIONAL ELECTRONICS LLC Test and Measurement Calibration Services Test Bench www.anaum.ae About Us Located in the Musaffah, Abu Dhabi, United Arab Emirates, Anaum International Electronics
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 METTLER TOLEDO (INDUSTRIAL) 1900 Polaris Parkway Columbus, OH 43240 Frank Gardone Phone: 412 213 2263 CALIBRATION Valid To: April 30,
More informationFor the National Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Florida Department of Agriculture Metrology Laboratory 3125 Conner Blvd. Lab #2 Tallahassee, FL 32399-1650 Ms. Amy Smith Phone: 850-921-1570 Fax: 850-921-1593
More informationHydraulic Deadweight Tester Model CPB5800
Calibration technology Hydraulic Deadweight Tester Model CPB5800 Applications Primary standard for ranges up to 20,000 psi hydraulic Pressure reference / calibration standard used in production and calibration
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, hertsey Lane, Staines-upon-Thames, TW18 3HR, UK ISO/IE 17025:2005 Unit 3 24-26 Boulton Road Stevenage Hertfordshire SG1 4QX ontact: Mr G J Wilson Tel: +44 (0) 1438 900080 Fax: +44 (0) 1438
More informationSCOPE OF ACCREDITATION TO ISO/IEC & KS Q ISO/IEC
SCOPE OF ACCREDITATION TO ISO/IEC 17025-2005 & KS Q ISO/IEC 17025-2006 Korea Instrument Co., Ltd. Branch 45, Gwangjang-ro 56beon-gil, Sasang-gu, Busan 46976 Phone : 051-322-0880, Fax : 051-322-4066, E-mail
More informationFORCE SENSORS FORCE SENSORS
FORCE SENSORS We are a pioneer in the design and manufacture of precision force sensors for applications that require high performance or unique packaging, including electromechanical flight control, test
More informationAn ISO 9001 : 2008 Certified Company
::: CAR BODY COLLISION BENCHES ::: :: Model :- W-1000 :: Max. lifting capacity Platform length Platform width Platform height Hydraulic pressure Post max. tension Post working range Pneumatic pressure
More informationFlow Research and Test Center
SALES BULLETIN Flow Research and Test Center CREATING RESOURCE TECHNOLOGY FOR TODAY AND TOMORROW The key to FMC Technologies success has been its ability to provide the latest technology in products and
More informationCheck Points. for Measuring Instruments
Check Points for Measuring Instruments Introduction Measurement the word can mean many things. In the case of length measurement, there are many kinds of measuring instruments and their corresponding measuring
More informationCHAPTER 4 VARIABLE COMPRESSION RATIO ENGINE WITH DATA ACQUISITION SYSTEM
57 CHAPTER 4 VARIABLE COMPRESSION RATIO ENGINE WITH DATA ACQUISITION SYSTEM 4.1 GENERAL The variable compression ratio engine was developed by Legion brothers, Bangalore, India. This chapter briefly discusses
More informationPressure Instrument Testing Equipment
Pressure Instrument Testing Equipment BULLETIN TE-1 A Halliburton Company A Durable, Portable Primary Standard Model 1305D Deadweight Tester The Ashcroft 1305D Deadweight Tester is an affordable, portable
More informationPrecisa Gravimetrics AG
Precisa Gravimetrics AG Paolo Fancelli, Designer With Series 321, Precisa is in today s mindset: offering active, modern thinking professionals the enjoyment of using well designed even trendy products
More informationBRAKE BOOSTER. Section 5. Brake Booster. Construction. Single Diaphragm Booster
BRAKE BOOSTER Brake Booster The brake booster is designed to create a greater braking force from a minimum pedal effort, using a difference in atmospheric pressure and the engine s manifold vacuum. It
More informationMeasuring tools. Accuracy in measurement. Test-safe use. Multiple versions. Torque wrenches. Vernier calipers Spirit levels Mason s profiles
Measuring tools Torque wrenches Vernier calipers Spirit levels Mason s profiles Try squares Feeler gauges Other measuring tools Measuring tapes Accuracy in measurement Measuring tapes, torque wrenches
More information