Catalogue January 2013, R 2.0

Size: px
Start display at page:

Download "Catalogue January 2013, R 2.0"

Transcription

1 Catalogue January 2013, R 2.0

2

3 TV4000 with TVS and Manifold for ASTM D2171 See page 24

4 Content 1 ASTM Equipment How to select the appropriate viscosity bath? ASTM D445 High Temperature Viscosity Baths Small and Precise Viscometer Bath: TV General purpose Viscosity Bath: TV Semi Automatic Viscosity Measuring: TV2000AKV Low Temperature Viscosity Bath: TV12LT Low Temperature Viscosity Baths 40 & 70 litres Ultra Low Temperature Viscosity Bath ASTM D2162 Master Viscometer Bath: TV Extremely Stable Thermostatic bath: TV ASTM D2171 Set-up for Viscosity of Bitumen ASTM D130 Copper Corrosion IP227 Silver Corrosion ASTM D1796 Water & Sediment in Fuel Oils ASTM D1298 Density by Hydrometer ASTM D1265 Sample Container ASTM D2068 Filter Blocking Tendency High Temperature Baths How to select the appropriate circulator? Tamson Bracket - TB Tamson Circulator - TCB Line Tamson Circulator TC Line Low Temperature Baths How to select the appropriate cooler? Tamson Cooling Circulators TLC Line Tamson Cooling Circulators TLC Line Tamson Cooling Circulators TLC Line Tamson Cooling Circulators TLC Line New Tamson Cooling Circulators Tamson Immersion Coolers KV Line... 51

5

6 Ta m son sets the standard Introducing Tamson Founded in 1878, Tamson began as a wholesaler in laboratory equipment in the field of chemistry and physics. By the 1950's the product range had diversified into a chemical field providing baths and circulators for industry. This business generated 60 years of dedicated experience within this specialized field, reflecting upon the success, quality and high performance of the company's products. We are proud on using the Tamson name which stands for quality, precision and reliability. In January 1998, the company name has changed to BV, when the production and wholesaler department were separated. In 2008, BV moved to a new office in Bleiswijk near Rotterdam, The Netherlands. All Tamson products are manufactured in The Netherlands. Product range We offer a quality range of cooling and heating circulators. Our products provide reliable and very accurate temperature regulation of fluids. An accuracy beyond Kelvin can be achieved. The product range provides exact temperature controlling from -100 C to +250 C. Our equipment can be found in many diverse areas of research across industrial fields such as petroleum industry, universities, research institutes and quality control laboratories. Our main markets are being found in chemical, quality control and product processing, along with research and development industries. In this catalogue, the Tamson product range is divided into five groups: 1) ASTM Equipment 2) High Temperature Baths 3) Low Temperature Baths 4) Accessories 5) Calibration & Thermometers Tamson sets the standard BV is an innovative manufacturer and is ahead in the newest developments and technologies. We develop, design, and produce state-of-the-art thermostatic baths, coolers, circulators and calibration instruments. Tamson continuously invests into environmental standards. Our products operate with amazing high accuracy, long life quality, and reliability. As a manufacturer, we continually strive to enhance our products and we are extending our product range in order to better serve our customers needs. In our markets for manual kinematic viscosity and calibration baths we set the standard. More in-depth technical information regarding the products can be found in the specification sheets and manuals which can be downloaded from our website. We look forward to be receiving your questions, feedback and further requests.

7 ASTM EQUIPMENT 5

8 1 ASTM Equipment 1.1 How to select the appropriate viscosity bath? Temperature range Setting ( C) Offset Stability Heating (W) Heaters Built in light Removable outside window Bath Volume (L) Number of lids Opening bath (mm) Depth bath (mm) Dimensions (LxWxH) Weight (kg) Stirring included Cooling coil Cataloque section ASTM Method Drain Overflow outlet Integrated cooling TV2000 (1)** TV4000 (2)** TV4000DC (3)** TV7000 (4)** Ambient..230 C (1,2,4) ±0.01 C (3) ±0.002 C@40 C No Yes (1) 20 (2,3) 40 (4) - 70 (1) 3 (2,3,4) 7 or 8 (1) 130 * 165 (2,3) 260 * 240 (4) 260 * 240 (1) 300 (2,3) 300 (4) (1) 285*465*585 (2,3) 350*590*585 (4) 350*630*885 (1) 40 (2,3) 41 (4) 61 Yes Yes 1.2 D445+D2162 (for 4) Yes Yes No TV12** Ambient..120 C ±0.005 C Yes Yes * *365* Yes Yes 1.2 D445 Yes Yes No TV2500** Ambient..120 C ±0.02 C No No * *204* Yes Yes 1.2 D445 Yes Yes No TV2000AKV** Ambient..130 C ±0.01 C No No * *465* Yes Yes 1.3 D445 Optional No No TV12LT* -40 C..+20 C ±0.01 C Yes Yes * *425* Yes No 1.4 D445 Yes Yes Yes TV4000LT (1) TV7000LT (2) -40 C C ±0.02 C No No (1) 40 (2) or * (1) - 560*492*1150 (2) - 560*492*1450 (1) 100 (2) 120 Yes No 1.4 D445+D2162 (for 2) Yes Yes Yes TLV25-80 C..+60 C ±0.04 C Yes No Ø *410* Yes No 1.4 D445 No No No TV C..+60 C ±0.007 C No No 155 On request 230 * *420* Yes No 1.5 D445+D2162 Yes Yes Yes TV C..+60 C ±0.005 C No No * *575* Yes No 1.5 D445 Yes Yes Yes * Optional C and C ** With External Cooler from +10 C possible Viscosity Baths 6

9 ASTM Equipment 1.2 ASTM D445 High Temperature Viscosity Baths ASTM D445 ASTM D2162 ASTM D ISO/EN 3104 IP 71 DIN This test method specifies a procedure for the determination of the kinematic viscosity of liquid petroleum products, both transparent and opaque, by measuring the time for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer. Main Characteristics Bath can be operated from ambient +5 C up to +230 C ( F). With the use of the built-in cooling coil and an external Tamson cooler, span lies 5K above the temperature of the cooling liquid. The TV2000, TV4000 and TV7000 have a bath volume of 20, 40 and 70 liters respectivily. The TV2000 has a cover with 3 openings and lids. The TV4000 and TV7000 have a cover with 7 openings and lids. These openings accommodate glass capilary viscometers in viscometer holders. The TV4000DC has the same specifications as the TV4000, but with a unique stability of C at 40 C. The TV7000 is often used to calibrate long thermometers, to calibrate master viscometers or for oxidation stability tests. A bath overflow outlet protects from expanding bath oil when the bath filling is increasing at higher temperatures. A bath drain is standard included. The bath is fitted with a double window of which the front pane is detachable for cleaning purposes. TV4000 TV2000 TV4000 TV4000DC TV7000 Range 230 C/ 446 F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.01 C Offset 0.01 C (optional C) Stability ± 0.01 C 0.01 C C@40 C 0.01 C C@100 C C@150 C Heating 3000 W Heaters 2 Bath volume 20 L 40 L 40 L 70 L Number of Ø 51 mm lids 3 (4 optional) (4 + 4 optional) Window 140 * 285 mm 270 * 285 mm 270 * 585 mm Opening bath 130 * 165 mm 260 * 240 mm 260 * 240 mm Depth bath 300 mm 300 mm 600 mm TV2000 REF 00T0782 (230V/50-60Hz) REF 00T0784 (115V/60Hz) TV4000 REF 00T0772 (230V/50-60Hz) REF 00T0774 (115V/60Hz) TV4000DC REF 00T0802 (230V/50-60Hz) REF 00T0804 (115V/60Hz) TV7000 REF 00T0792 (230V/50-60Hz) REF 00T0794 (115V/60Hz) TV2000 TV4000 TV7000 7

10 ASTM Equipment Options TV TV TV40 0 0DC TV Cover with 4 holes (Ø 51 mm) + lids REF 03T3211 and 2 holes for ASTM thermometers (Ø 12.5 mm) REF 03T2113 Cover with 3 holes and lids (Ø 60 mm) Cover with 8 holes (Ø 51 mm) + lids REF 00T0729 and 2 holes for ASTM thermometers (Ø 12.5 mm) REF 03T2112 Cover with 8 holes and lids (Ø 60 mm) On request Custom made leveling platform On request Custom made cover for leveling platform For Viscosity Accessories, see section Viscosity Accessories Acce ssories TV TV TV40 0 0DC TV REF 00T0900 Illuminator Z41 230V/50-60Hz (Background light) REF 00T0910 Illuminator Z71 230V/50-60Hz (Background light) REF 10T6065 Viscohanger REF 10T Channel Stop-watch REF 00T0239 ASTM Thermometer holder REF 00T0220 REF 08T0001 REF 00T0238 REF 00T0050 REF 00T0565 REF 00T0520 Tamson mineral oil 20ltrs Transparent ( C) Silicon oil cst 20ltrs Transparent ( C) Silicon oil ltrs Transparent ( C) TLC10-3 external cooler to work below ambient temperature TLC15-5 external cooler to work below ambient temperature TLC40-14 external cooler to work below ambient temperature Ultra high stability TV2000 TV4000 TV7000 8

11 ASTM Equipment Main Spare parts 2 3 0V / Hz (1 1 5 V-6 0 Hz o n reque st) TV TV TV40 0 0DC TV REF 06T0500 Microprocessor board TMC70 REF 06T0512 PCB Power TMC70 REF 06T0509 Print Front Panel TVMKII with LED REF 28T4026 PT-100 sensor REF 04T0063 Stirrer complete REF 04T0081 Stirrer complete REF 25T0210 Heater 1500 W REF 28T4022 Heater 1500 W REF 28T4322 Front foil with membrane switches REF 28T4009 Front foil with membrane switches REF 06T0508 PCB front panel with LCD and connector to keys REF 24T8541 Mains switch REF 25T1242 Fan REF 24T8581 Safety cut-out thermostat REF 06T0502 PCB display TMC70 All product details at TV2000 TV4000 TV7000 9

12 ASTM Equipment 1.3 Small and Precise Viscometer Bath: TV12 ASTM D445 ISO/EN 3104 IP 71 DIN Main Characteristics The TV12 is a unique viscosity bath with a small footprint. The TV12 can be operated from ambient +5 C up to +120 C ( F). With the use of the built-in cooling coil and an external Tamson cooler, span lies 5K above the temperature of the cooling liquid. The TV12 has a bath volume of only 12 liters and a unique stability of 0.005K. The TV12 offers 1 row of 4 holes with lids. These openings will accommodate glass capillary viscometers in viscometer holders. A permanent LED light is located in the top plate to supply clear light and guarantees optimal visibility inside the bath. A bath overflow outlet protects from expanding bath fluid when the bath filling is too high. A bath drain is standard included. The bath is fitted with a double window of which the front pane is detachable for cleaning purposes. TV12 Range 120 C/ 248 F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.01 C Offset 0.01 C Stability ± K Heating 1280 W Heaters 2 Bath volume L Number of lids 4 Window 140 * 285 mm Opening lid Ø 51 mm Opening bath 248 * 73 mm Depth bath 300 mm All product details at TV12 REF 00T0400 (230V/50-60Hz) REF 00T0405 (115V/60Hz) For spare parts, options and accessories, please see our TV12LT TV12 10

13 ASTM Equipment 1.4 General purpose Viscosity Bath: TV2500 ASTM D445 ISO/EN 3104 IP 71 DIN European Pharmaceutic Main Characteristics The TV2500 bath can be operated from ambient +5 C up to +120 C ( F). With the use of the built-in cooling coil and an external Tamson cooler, span lies 5K above the temperature of the cooling liquid. The TV2500 has a bath volume of 25 liters. The TV2500 offers two rows of 2 holes with lids. These openings will accommodate glass capillary viscometers in viscometer holders. Range 120 C/ 248 F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.1 C (optional 0.01 C) Stability ± 0.02 K Heating 1800 W Heaters 1 Bath volume 25 L Number of lids 4 Window 230 * 300 mm Opening lid 51 Ø mm Opening bath 185 * 155 mm Depth bath 300 mm TV2500 For ASTM D1298 you can use the TV2500 in combination with a special cover with 4 holes (REF 03T2119) and a TLC10-3 cooling circulator. Please also see section ASTM D1298 Density by Hydrometer. TV2500 REF 19T1003 (230V/50-60Hz) REF 19T1004 (115V/60Hz) All product manuals are available at TV2500 for ASTM D1298 TV

14 ASTM Equipment Options TV REF 07T0800 Level detection (Floater) REF 02T0210 Safety window for use PV>50 C REF 02T0200 Leakage tray REF 02T C display readout REF 03T2118 Cover with 3 holes and lids Ø60 mm Acce ssories REF 00T0900 Illuminator Z41230V/50-60Hz (Background light) For Viscosity Accessories, see section Viscosity Accessories ASTM D4 4 5 REF 10T6065 Viscohanger REF 10T Channel Stop-watch ASTM D REF 00T0239 ASTM Thermometer holder REF 00T0220 Tamson mineral oil 20ltrs Transparent ( C) REF 08T0001 Silicon oil cst 20ltrs Transparent ( C) REF 00T0050 TLC10-3 external cooler to work below ambient temperature REF 03T2119 REF DCP Cover with 4 holes (Ø 61 mm ) for hydrometer cylinder ASTM D1298 Hydrometer cylinder for ASTM D1298 Main Spare parts V / Hz (1 1 5V-6 0Hz o n req ue st) TV REF 25T1295 Motor 30 W REF 25T0360 Heater 1800 W REF 06T0514 PCB Power TMC70 REF 24T8581 Safety cut-out thermostat REF 28T4023 Front foil keypad REF 25T2310 PT-100 sensor REF 25T1343 Capacitor 2uF REF 25T0513 PCB Display TV

15 ASTM Equipment 1.5 Semi Automatic Viscosity Measuring: TV2000AKV ASTM D445 ISO/EN 3104 IP 71 DIN Main Characteristics The TV2000AKV system offers a possibility to determine kinematic viscosity automatically in a way wich complies to the ASTM methods D445 and D446. The measuring head is able to measure both transparent and coloured / darker liquids. The sensitivity of the electronic detection system can be adapted for coloured liquids. The measuring head can store up to ten viscometer glass capillary constants. It is further possible to set the amount of runs (tests) per sample. The system determines the best reproducibility from the measuring results. The TV2000AKV can be operated from ambient +5 C up to +130 C. With the use of the built-in cooling coil and an external Tamson cooler, span lies 5K above the temperature of the cooling liquid. The TV2000AKV has a bath volume of 20 liters. The viscosity measurement range is defined by the used glass capillaries and may vary from 0.3 up to 10,000 cst. Range 130 C/ 266 F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.1 C Offset 0.01 C Stability ± 0.01 K Heating 2800 W Heaters 3 Bath volume 20 L Number of lids 1 Window 140 * 285 mm Opening bath 130 * 165 mm TV2000AKV TV2000AKV REF 00T0820 (230V/50-60Hz) REF 00T0830 (115V/60Hz) Check for more technical details TV2000AKV 13

16 ASTM Equipment Ne ce ssary ac ce ssories TV20 0 0AKV REF 00T0890 Measuring head for Cannon Fenske Routine viscometers REF 00T0840 Measuring head for Ubbelohde viscometers REF 00T0233 Vacuum Pump with Teflon valves Acce ssories TV20 0 0AKV REF 00T0239 ASTM Thermometer holder REF 08T0001 Silicon oil cst 20ltrs Transparent ( C) REF 00T0565 TLC15-5 external cooler to work below ambient temperature REF 00T0900 Illuminator Z41 230V/50-60Hz (Background light) Main Co nsu mables 28T0730 Printer Ribbon 28T0735 Printer Paper 06T1723 Stopper for viscometer 24T0043 Silicon Tubing For Viscosity Accessories, see section Viscosity Accessories TV2000AKV 14

17 ASTM Equipment 1.6 Low Temperature Viscosity Bath: TV12LT ASTM D445 ISO/EN 3104 IP 71 DIN This test method specifies a procedure for the determination of the kinematic viscosity of liquid petroleum products, both transparent and opaque, by measuring the time for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer. Main Characteristics The TV12LT with integrated cooling is a unique viscosity bath with a small footprint. It can be operated from -40 C up to +20 C ( F). Ranges from -40 C up to +80 C and -50 C up to +20 C are available. The TV12LT has a bath volume of only 15 liters and a unique stability. The TV12LT offers 1 row of 4 holes with lids. These openings will accommodate glass capillary viscometers in viscometer holders. A permanent light is located in the top plate to supply clear light and guarantees optimal visibility inside the bath. A bath overflow outlet protects from expanding bath fluid when the bath filling is too high. A bath drain is standard included. The bath is fitted with two windows of which the front panel is detachable for cleaning purposes. The TV12LT also is a perfect bath to calibrate thermometers or other sensors. Range C*/ F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.01 C Offset 0.01 C (optional C) Stability ± 0.01 K Heating 1280 W Heaters 2 Bath volume L Number of lids 4 Window 255 * 230 mm Opening lid Ø 51 mm Opening bath 248 * 73 mm TV12LT TV12LT REF 00T0410 (230V/50Hz) REF 00T0420 (230V/60Hz) REF 00T0415 (115V/60Hz) * Range from -40 C up to +80 C TV12LT REF 00T0425 (230V/50Hz) REF 00T0435 (230V/60Hz) REF 00T0430 (115V/60Hz) * Range from -50 C up to +20 C TV12LT REF 00T0470 (230V/50Hz) REF 00T0480 (230V/60Hz) REF 00T0475 (115V/60Hz) All manuals available at TV12LT 15

18 ASTM Equipment Options TV12 TV12 LT REF 07T0080 Optical level indicator (Floater) REF 13T6200 Leveling platform REF 13T6210 Calibration / metal block REF 13T6220 Lid + High contrast white glass back plate REF 13T Lid for 4 Cannon-Fenske Routine viscometers REF 03T2117 Cover with 4 holes and lids (60 Ø mm) Acce ssories TV12 TV12 LT REF 10T6065 Viscohanger REF 10T Channel Stop-watch REF 00T0239 ASTM Thermometer holder REF 00T0220 Tamson mineral oil 20ltrs Transparent ( C) REF 08T0001 Silicon oil cst 20ltrs Transparent ( C) REF 00T0050 TLC10-3 external cooler to work below ambient temperature For Viscosity Accessories, see section Viscosity Accessories Main Spare parts 2 3 0V / Hz (1 1 5V-6 0 Hz o n reque st) TV 1 2 TV12 LT REF 25T1295 Motor 30 W REF 25T1343 Capacitor 2uF REF 25T0340 Heater 780 W REF 25T0351 Heater 500W REF 24T0028 Power supply 500 W REF 24T8081 Motor fuse 0.3 Amp REF 25T1123 Compressor REF 25T1243 Fan 12VDC REF 25T0404 Window heating (4 x 115V placed in series) REF 24T8581 Safety cut-out thermostat REF 24T8545 Mains switch REF 28T4019 Front keypad REF 25T2310 PT-100 sensor REF 28T4125 Net entry plus filer 10A REF 06T0512 PCB Power TMC70 REF 06T0500 Microprocessor board TMC70 REF 06T0503 PCB IO DC PWM Heating REF 06T0505 Print TMC70 IO/Cooler LT-version REF 06T0507 PCB - Display TV12LT 16

19 ASTM Equipment 1.7 Low Temperature Viscosity Baths 40 & 70 litres ASTM D445 ASTM D ISO/EN 3104 IP 71 DIN Main Characteristics The TV4000LT and TV7000LT are unique visibility baths with wide dimensions. Working temperature ranges from -40 C up to +100 C. The integrated cooling system is able to lower the temperature of the bath content down to -40 C within approximately 2 hours. The cooling power can be controlled over 4 stages, so that the heat removal capacity is trimmed to the desired set point temperature, saving up to 50% of energy. Due to its wide temperature range, the bath can be used for multiple purposes varying from low temperature viscosity measurement to calibration of sensors and thermometers. The large windows show the bath contents clearly. The windows are heated preventing built up of condensate. The maximum temperature lies around +100 C. Overall accuracy is better than +/ C over the whole temperature range. Ambient temperature drifts <0.003 C/ C. The homogeneity is better than 0.02 C. Drift, accuracy and homogeneousness were measured with methanol as bath medium and are true min-max values found over 8 hours. The TV7000LT can be used to calibrate long thermometers or to calibrate master viscometers conform ASTM D2162. TV4000LT TV4000LT TV7000LT Range C/ F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.01 C Offset 0.01 C Stability ± 0.02 C Heating 2000 W Heaters 2 Bath volume 40 L 70 L Number of lids (4 + 4 optional) Window 270 * 285 mm 270 * 585 mm Opening lid Ø 51 mm Opening bath 260 * 240 mm Depth bath 300 mm 600 mm TV4000LT REF 00T0460 (230V/50Hz) REF 00T0462 (230V/60Hz) REF 00T0465 (115V/60Hz) TV7000LT REF 00T0450 (230V/50Hz) REF 00T0452 (230V/60Hz) REF 00T0455 (115V/60Hz) TV4000LT-TV7000LT 17

20 ASTM Equipment Options TV LT TV LT Cover with 8 holes (Ø 51 mm) + lids and 2 holes for REF 00T0729 ASTM thermometers (Ø 12.5 mm) REF 03T2112 Cover with 8 holes and lids (Ø 60 mm) REF 00T0900 REF 00T0910 Illuminator Z41 230V/50-60Hz (Background light) Illuminator Z71 230V/50-60Hz (Background light) Acce ssories TV LT TV LT REF 13T3725 Undercarriage REF 10T6065 Viscohanger REF 10T Channel Stop-watch REF 00T0239 ASTM Thermometer holder For Viscosity Accessories, see section Viscosity Accessories Main Spare parts 2 3 0V / Hz (1 1 5V-6 0 Hz o n reque st) TV LT REF 04T0081 Stirrer complete TV LT REF 04T0063 Stirrer complete REF 25T0215 Heater 500/1500 W REF 28T4009 Front foil with membrane switches REF 24T8545 Mains switch REF 24T8581 Safety cut-out thermostat REF 25T2320 PT-100 sensor REF 06T0500 Microprocessor board TMC70 REF 06T0517 PCB TMC70 IO REF 06T0505 Print TMC70 IO/Cooler LT-version REF 06T0512 PCB Power TMC70 Viscosity Calibration or Testing TV4000LT-TV7000LT 18

21 ASTM Equipment 1.8 Ultra Low Temperature Viscosity Bath ASTM D445 ISO/EN 3104 IP 71 DIN Main Characteristics The TLV25 system contains a 25 litres Dewar flask. The fluid in this flask must permanently be cooled by a separate cryostat. The temperature set point is maintained via a microprocessor controlled heating element. When using the KV40 or KV80 minimum working temperatures of -40 C or -80 C can be reached. All presented data is measured by using a TLV25 filled with 25 litres of methanol and a KV40 or KV80 immersion cooler. At the minimum temperature, the provided heat removal is still enough to maintain stable temperature control, even when glass capillaries are placed in the bath. The systems accuracy is better than the requirements of ASTM D 445 and ISO The bath is illuminated by a fluorescent light built-in behind the Dewar-flask. The top lid has a turn table construction with 3 holes + 3 lids. By turning the lid, the immersed viscometer can be positioned in front of the window. This window is heated to keep clear sight at low temperatures. The set point can be set in steps of 0.1 C from -90 C up to +60 C ( F). Overall accuracy is better than ±0.04K. TLV25 Range C/ F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.1 C Offset 0.1 C Stability ± 0.04 K Heating 1500 W Heaters 1 Bath volume 25 L Number of lids 3 Opening lid Ø 51 mm Opening bath 260 * 240 mm Depth bath 400 mm TLV25 REF 00T0650 (230V/50-60Hz) REF 00T0780 (115V/60Hz) Please also see our KV line where you will find the necessary immersion coolers for the TLV25. TLV25 19

22 ASTM Equipment Ne ce ssary options TLV2 5 REF 00T0212 KV40 to reach -40 C (230V/50HZ) REF 00T0212A KV40 to reach -40 C (230V/60HZ) REF 00T0259 KV40 to reach -40 C (115V/60HZ) REF 00T0216 KV80 to reach -80 C (230V/50HZ) REF 00T0216A KV80 to reach -80 C (230V/60HZ) REF 00T0260 KV80 to reach -80 C (115V/60HZ) Acce ssories TLV2 5 REF 10T6065 Viscohanger REF 10T Channel Stop-watch REF 00T0239 ASTM Thermometer holder For Viscosity Accessories, see section Viscosity Accessories Specification sheets at TLV25 20

23 ASTM Equipment 1.9 ASTM D2162 Master Viscometer Bath: TV16000 ASTM D ASTM D445 ISO/EN 3104 IP 71 DIN Main Characteristics This thermostatic bath is specially designed for tests that require ultra precise temperature control, or processes that need to be followed visually. The bath conforms to ASTM D445: Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids and ASTM D2162: primary Basic Calibration of Master Viscometers and Viscosity Oil Standards. Other applications are thermometer and sensor calibration or density measurement. When using a metal block (thermo well) inside the bath, stabilities of ±0.005K can be achieved. A stirrer moves the bath fluid past a special heater ensuring optimal temperature control and ensuring excellent uniformity. The bath conforms to CE-regulation. Further the bath is equipped with a mechanical over-temperature device which trips when in case of malfunction the bath exceeds the preset maximum temperature. This feature guarantees safe around the clock operation. TV16000 Range C/ F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± C Stability ± K Uniformity <0.005 K Heating 2500 W Heaters 2 Bath volume 160 L Opening bath 250 * 365 mm Depth bath 965 mm Dimension (LxWxH) 575 x 575 x 1700 mm Weight 135 kg TV16000 REF 00T0490 (230V/50Hz) REF 00T0492 (230V/60Hz) REF 00T0495 (115V/60Hz) For options and spare parts, please see our TV15000 TV

24 ASTM Equipment 1.10 Extremely Stable Thermostatic bath: TV15000 IUPAC ASTM D445 ASTM D ISO/EN 3104 IP 71 DIN Main Characteristics The thermostatic bath has been developed to measure ph according to IUPAC recommendations 2002 "Measurement of ph. Definition, standards, and procedures". IUPAC recommends definitions, procedures, and terminology relating to ph measurements in dilute aqueous solutions in the temperature range from 5 C to 50 C. With this unique TV15000 you can measure the ph at 5 C, 15 C, 25 C, 37 C, and 50 C, where the temperature has to be maintained within ± 0.01 C of the set point. For this purpose this bath is used by national metrological institutions. Also, this bath can be used for tests that require ultra precise temperature control, or processes that need to be followed visually. Examples are thermometer and sensor calibration, and density measurement. When using a metal block (thermo well) inside the bath, stabilities of ± can be achieved. Range C / F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± K Stability ± K Uniformity < K Heating 2500 W Heaters 2 Bath volume 155 L Opening bath 230 * 820 mm Depth bath 650 mm Dimension (LxWxH) 1170 x 420 x 1400 mm Weight 130 kg TV15000 TV15000 REF 00T0500 (230V/50Hz) REF 00T0505 (230V/60Hz) REF 00T0502 (115V/60Hz) More product details at TV

25 ASTM Equipment Options TV TV On request Top lid closed On request Top lid 51 mm holes (9 holes) On request Top lid 61mm holes (6 holes) On request Leveling platform with calibration block For Viscosity Accessories, see section Viscosity Accessories Main Spare parts 2 3 0V / Hz (1 1 5V-6 0 Hz o n reque st) TV TV REF 06T0512 PCB Power TMC70 REF 25T1104 Compressor REF 24T8081 Motor fuse 0.3 Amp REF 25T0215 Heater 500/1500 W REF 25T1295 Motor 30 W REF 25T1244 Fan REF 06T0505 Print TMC70 IO/Cooler LT-version REF 06T0503 PCB IO DC PWM Heating REF 06T0525 PCB window heating REF 24T0028 Power supply 500 W REF 24T8581 Safety cut-out thermostat REF 25T0351 Heater 500W REF 06T0507 PCB - Display REF 25T2310 PT-100 sensor REF 24T8545 Mains switch REF 06T0500 Microprocessor board TMC70 TV

26 ASTM Equipment 1.11 ASTM D2171 Set-up for Viscosity of Bitumen ASTM D2171 IP 122 EN AASHTOT202 This test method covers procedures for the determination of viscosity of asphalt (bitumen) by vacuum capillary viscometers at 60 C. It is applicable to materials having viscosities in the range from to over 20,000 Pa. Main Characteristics The Tamson Vacuum System (TVS) is designed for precise measurement and control of vacuum at 300 mm Hg below atmospheric pressure. The TVS is equipped with an internal vacuum pump. The internal set points for the instrument gauge are preset at Tamson to regulate vacuum at 300 ± 0.5 mm Hg below atmospheric pressure (the vacuum required by ASTM D 2171). These set points may be altered to fit the user s specific needs within the TVS operating range of 0 to 350 mm Hg below atmospheric pressure. In asphalt laboratories the TVS may be used in conjunction with Cannon-Manning, Asphalt Institute, and Modified Koppers vacuum viscometers for measurement of highly viscous materials such as asphalt cement at 60 C (140 F) according to ASTM D The TVS is also useful in other laboratory systems where accurate measurement and control of vacuum is required. For ASTM D2171 Tamson supplies a TV4000, a TVS and a 4 position manifold. With this setup four viscometers can be used. For further information on the TV4000, please see section 1.2. TVS REF 00T0940 (85~230V) Manifold REF 00T0941 TV4000 with TVS and Manifold for ASTM D2171 For Viscosity Accessories, see section Viscosity Accessories Ne ce ssary options ASTM D REF 00T0772 TV4000 Viscosity bath (230V/50-60Hz) REF 00T0940 Tamson Vacuum System V/50-60Hz REF 00T0941 TV4000 manifold for 4 positions with tubing Acce ssories ASTM D REF 00T0900 Illuminator Z41 230V/50-60Hz (Background light) REF 10T6065 Viscohanger REF 10T Channel Stop-watch REF 00T0239 ASTM Thermometer holder REF 08T0001 Silicon oil cst 20ltrs Transparent Vacuum System 24

27 ASTM Equipment 1.12 ASTM D130 Copper Corrosion ASTM D130 EN/ISO 2160 IP 154 DIN51811 ASTM D4048 IP 112 Main Characteristics This test method covers the detection of the corrosiveness to copper of aviation gasoline, aviation turbine fuel, automotive gasoline, natural gasoline or other hydrocarbons having a Reid vapour pressure no greater than 18 psi. The bath has positions for six test stations, each with a lid and hook for suspending a copper corrosion test vessel or a test tube. The temperature range is from ambient +5 C to 250 C. The bath conforms to CE regulation. It is further equipped with a mechanical resettable safety thermostat. When not used for copper corrosion tests, the pump can be used to circulate the bath content to an external application. Range..250 C/ 482 F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.1 C Stability ± 0.02 K Heating 1500 W Bath volume 16 L Opening bath 6* 51 mm Depth bath 200 mm Pump (mbar) Max pressure 300 (optional 1 mbar) Pump (L/min) Max flow 7.5 (optional 16) Dimension (LxWxH) 455 x 295 x 440 mm Weight 21 kg Copper Corrosion for ASTM D130 TC16 (for ASTM D130) REF 31T0671 (230V/50-60Hz) REF 31T0861 (115V/60Hz) Test Cylinder with o-ring Copper Corrosion 25

28 ASTM Equipment Ne ce ssary Accessories ASTM D1 3 0 ASTM D REF 14T0100 Test Cylinder with o-ring REF 31T0003 ASTM Copper Strip Corrosion Test Standard REF 31T0002 Copper strip pack of 10 REF 31T0001 Sanding paper Silicon Carbide P220 REF 09T0010 Test tube 25 x 150 mm REF 14T0102 Test tube holder REF 31T0000 Multi-Strip Vice, holds up to five strips while polishing REF 31T0005 Silicon carbide powder 105-um (1 kg) REF 09T0011 Flat glass tube REF 25T0911 ASTM Thermometer 12C REF 08T0001 Silicon oil cst 20ltrs Transparent ( C) REF 00T0239 Thermometer holder For spare parts, please see section of the TC16 in 2.3 For detailed overview see Test Tube in Holder Copper Corrosion 26

29 ASTM Equipment 1.13 IP227 Silver Corrosion Test IP 227 Main Characteristics This test method specifies a method for the determination of the corrosive tendencies towards silver, of aviation turbine fuel. The result is classified as an integer in the range 0 to 4. The bath offers place for six test tubes. The temperature range is from ambient +5 C to 250 C. The bath conforms to CE regulation. It is further equipped with a mechanical resettable safety thermostat. Range..250 C/ F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.1 C Stability ± 0.02 K Heating 1500 W Bath volume 16 L Opening bath 9 * 51 mm Depth bath 200 mm Pump (mbar) Max pressure 300 (optional 1 mbar) Pump (L/min) Max flow 7.5 (optional 16) Dimension (LxWxH) 455 x 295 x 440 mm Weight 21 kg Silver corrosion for IP227 TC16 (for IP227) * REF 31T0671 (230V/50-60Hz * REF 31T0861 (115V/60Hz) Ne ce ssary ac ce ssories IP REF 13T8000 Top lid. 6 holes 51mm (standard included) REF 14T0101 Lid and mounting hook (6 pieces standard included) REF 31T0300 Test Tube (amber glass) REF 31T0301 Cold-finger Condensor (amber +transparent glass) REF 31T0302 Glass Cradle REF 31T0303 Silver Strip (1 piece) REF 31T0304 Silver Strip standard (Color Code standard ASTM D3241) REF 31T0001 Sanding paper Silicon Carbide P220 Grits REF 31T0000 Multi-Strip Vice, holds up to five strips while polishing REF 31T0005 Siliconcarbide powder 105-um (1kg) REF 25T0911 ASTM thermometer 12C REF 00T0239 Thermometer holder Silver Corrosion Test 27

30 ASTM Equipment 1.14 ASTM D1796 Water & Sediment in Fuel Oils ASTM D91 ASTM D96 - ASTM D1796 ASTM D2273 API 2548 ASTM D4007 IP 359 DIN IP 75 Main Characteristics The test methods cover the determination for water and sediment in oils by the centrifuge method. The TC16 is according to the requirements of the methods to preheat the samples. Centrifuge is separately supplied by Tamson. The bath has place for nine centrifuge cones. The temperature range is from ambient +5 C to 250 C. With the levelling platform (reference 13T8010) you can immerse nine centrifuge cones in the vertical position to the 100- ml mark as indicated in the ASTM methods. The bath conforms to CE regulation. It is further equipped with a mechanical resettable safety thermostat. When not used to preheat samples, the pump can be used to circulate the bath content to an external application. Range..250 C/ 482 F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.1 C Stability ± 0.02 K Heating 1200 W Bath volume 16 L Opening bath 9 * Ø 51 mm Depth bath 200 mm Pump (mbar) Max pressure 300 (optional 1 mbar) Pump (L/min) Max flow 7.5 (optional 16) Dimension (LxWxH) 455 x 295 x 440 mm Weight 21 kg TC16 for ASTM D1796 TC16 for Centrifuge Cones REF 00T0671 (230V/50-60Hz) REF 00T0861 (115V/60Hz) Nece ssary a c ce ssories TC1 6 REF 13T8010 Leveling platform + holder for 9 centrifuge cones + 9 lids Water & Sediment 28

31 ASTM Equipment Tamson can also supply the centrifuge for petrol and mineral oils. The centrifuge has as main applications the determination of water and sediment in mineral oils, as well as the characterization of lubricants by centrifugation. Fitting different adapters it allows apply up to 10 different standards. Main Characteristics Induction motor maintenance free Controller by Microprocessor Noise level <60 db Automatic rotor recognition, it shows on screen max. RPM, max. RCF and max. capacity avoiding over speed Temperature regulation from ambient +5 C to +70 C Open selectable: automatic at the end of the cycle or manual pressing keypad Temperature selectable on C/ F RPM / RCF adjustable along run Centrifuge REF 31T0200 Centrifuge for Petrol and Mineral Oils Ne ce ssary Accessories Ce ntrifuge Swing out rotor for 4 tubes of ml (encoder) REF 31T rpm max, 2113 rcf max, with 4 buckets REF 31T0205 Adapters for rotor (REF31T0201) for pear-shaped tubes REF 31T0206 Pear-shaped tube 100 ml with 1,5 ml graduated tip REF 31T0207 Pear-shaped tube 100 ml with 3 ml graduated tip REF 31T0208 Adapters for rotor (REF31T0204) for 6 cone-shaped tubes REF 31T cone-shaped tube 100 ml (167 mm) Swing out rotor for 4 tubes cylinder-conical of 100mL 8 (encoder) REF 31T rpm max, 2425 rcf max, with 4 buckets REF 09T centrifuge cone REF 31T0202 Rubber stopper 14*19*24 mm (pack of 50 pcs) REF 31T0203 Cork stopper 15*18*25 (pack of 50 pcs) Options Ce ntrifuge REF 31T0210 Adapter for 4 finger tubes of 12,5 ml REF 31T0211 Adapter for 16 finger tubes of 12,5 ml REF 31T0212 Adapter for 28 finger tubes of 12,5 ml Water & Sediment 29

32 ASTM Equipment 1.15 ASTM D1298 Density by Hydrometer ASTM D287 ASTM D1298 ASTM D IP 160 ASTM E 126 Main Characteristics This specific method covers following laboratory determinations by hydrometer method: -Density, -Relative density (Specific gravity), -American Petroleum Institute Gravity of: Crude petroleum, Liquid Petroleum products. Products must have a Reid vapor pressure of 26 lb or less. A Tamson TLC15-5 refrigerator circulates a (cold) flow through the double walls of the cylinders. The TLC15-5 maintains the bath temperature within ± 0.25 C of the test temperature required by the method. The PTFE valves ensure fast drainage and cleaning of the cylinders. The easy detachable leakage tray prevents that portions of the sample are spilled on the workbench. The tripod offers full view on the hydrometer. Our special ASTM D1298 support eliminates the problem of mounting brackets or portions of a thermostatic bath blocking the view. The Tamson D1298 solution is a complete set-up existing of three glass cylinders, support and circulator. Our system offers an interesting price advantage compared to other solutions based on a combination of a thermostatic bath with an external chiller. The new ASTM D1298 set-up can also be used for ASTM D287, standard test method for API gravity of crude petroleum and petroleum products having a Reid vapour pressure of 26 psi (180 kpa) or less. For this method the gravities are determined at 60 F. Complete set-up D1298 Reading Menu selectable Interface RS232 Setting ± 0.01 C Stability ± Better than 0.1 K TLC15 Tripod Bath volume 5 L Opening bath 85 x 150 mm (effective use) Depth bath 150 mm Length 420 mm (460 mm incl drain) 360 mm (front to back) Width (left to right) Height mm Weight 30 kg 9 kg (glass parts included) Power 1100 W (1 heater) Ambient temperature C CE Products conform to CE regulation Set-up ASTM D1298 REF 00T2000 (230V/50Hz) REF 00T2001 (230V/60Hz) REF 00T2002 (115V/60Hz) An additional tripod is available to get a set-up for six positions with one circulator REF 00T1260 Alternative for this setup is: TV2500 in combination with the TLC10-3. For further information, please see section TV2500. Density 30

33 ASTM Equipment Acce ssories ASTM D REF 25T0911 ASTM Thermometer 12 C, range from -20 to +102 C with certificate of conformity REF 25T0911W ASTM Thermometer 12 C, range from -20 to +102 C with works certificate Hydrometers Reference Description L 50 series acc. to BS 718 Ref. temperature (Tp.): 15 C Measuring span: g/cm³ Scale units: g/cm³ Total length (L): 335 mm Reference Description M 50 series acc. to BS 718 Ref. temperature (Tp.): 15 C Measuring span: g/cm³ Scale units: g/cm³ Total length (L): 270 mm 25T2401 Hydrometer L50 15 C T2450 Hydrometer M50 15 C T2402 Hydrometer L50 15 C T2451 Hydrometer M50 15 C T2403 Hydrometer L50 15 C T2452 Hydrometer M50 15 C T2404 Hydrometer L50 15 C T2453 Hydrometer M50 15 C T2405 Hydrometer L50 15 C T2454 Hydrometer M50 15 C T2406 Hydrometer L50 15 C T2455 Hydrometer M50 15 C T2407 Hydrometer L50 15 C T2456 Hydrometer M50 15 C T2408 Hydrometer L50 15 C T2457 Hydrometer M50 15 C T2409 Hydrometer L50 15 C T2458 Hydrometer M50 15 C T2410 Hydrometer L50 15 C T2459 Hydrometer M50 15 C T2450 Hydrometer M50 15 C Description L 50 series acc. to DIN Ref. temperature (Tp.): 20 C Reference Measuring span: g/cm³ Scale units: g/cm³ Total length (L): 335 mm 25T2500 Hydrometer L50 20 C T2507 Hydrometer L50 20 C T2501 Hydrometer L50 20 C T2508 Hydrometer L50 20 C T2502 Hydrometer L50 20 C T2509 Hydrometer L50 20 C T2503 Hydrometer L50 20 C T2500 Hydrometer L50 20 C T2504 Hydrometer L50 20 C T2501 Hydrometer L50 20 C T2505 Hydrometer L50 20 C T2502 Hydrometer L50 20 C T2506 Hydrometer L50 20 C T2503 Hydrometer L50 20 C Buy online Density 31

34 ASTM Equipment Reference Description M 50 series acc. to DIN Ref. temperature (Tp.): 20 C Measuring span: g/cm³ Scale units: g/cm³ Total length (L): 270 mm 25T2550 Hydrometer M50 20 C T2555 Hydrometer M50 20 C T2551 Hydrometer M50 20 C T2556 Hydrometer M50 20 C T2552 Hydrometer M50 20 C T2557 Hydrometer M50 20 C T2553 Hydrometer M50 20 C T2558 Hydrometer M50 20 C T2554 Hydrometer M50 20 C T2559 Hydrometer M50 20 C REF 25T2400 ISO / UKAS calibration certificate can be ordered for each hydrometer Spare parts SETUP SET-UP Standard included whe n delivered f or the first time Glass tube, fluid jacketed hydrometer cylinder with stopper valve (3 per REF 09T0000 setup needed) REF 08T0100 Tubing 8 x 12 mm 1 meter (3 meter per setup needed) REF 08T0120 Plastic screw cap red with opening GL14 (6 per setup needed) REF 08T0122 Plastic hose connection angles GL14 (3 per setup needed) REF 08T0121 Plastic hose connection straight GL14 (3 per setup needed) REF 08T0125 Y split Polypro Pylene (2 per setup needed) REF 08T0126 T split Polypro Pylene (2 per setup needed) For main spare parts for the TLC15-5, please see our section `TLC Line Density 32

35 ASTM Equipment 1.16 ASTM D1265 Sample Container ASTM D1265 EN/ISO 4257 Main Characteristics Sample container conform EN ISO 4257 The 600 ml sampler enables to sample the mixture of liquefied gas propane-butane and ship the sample according to EU Directive 1999/36/EC and ADR agreement (medium nr 1965 according to ADR). The laser-engraved set of designations is placed on the outer surface of the cylinder section. Such designation is required by standards and includes important warnings regarding safety. The sampler is equipped with special protection which enables to seal the containers after cleaning. This ensures the container reaches the sampling point and then the testing facility (laboratory) intact, protected from third party access. The sampler is equipped with protection screens (top and bottom) according to requirements EN ISO PG 10/600 Capacity PG 10/2300 Capacity PG 10/3200 Capacity 600 ml 2300 ml 3200 ml Sample container with base and hose Sample container PG10/600 REF 31T0100 PG10/2300 REF 31T0105 PG10/3200 REF 31T0110 Options Sample c o ntainer REF 31T0115 Base PG02 + Hose REF 08T0100 Sampling pump REF 08T0120 PTFE lining in sample container REF 08T0122 Bottle cap On request Wide range of adapters Specification sheets available Sampling 33

36 ASTM Equipment 1.17 ASTM D2068 Filter Blocking Tendency ASTM D2068 IP 387 This test method covers three procedures for the determination of the filter blocking tendency (FBT) and filterability of middle distillate fuel oils and liquid fuels such as biodiesel and biodiesel blends. The 3 procedures and associated filter types, are applicable to fuels within the viscosity range of 1.3 to 6.0 mm2/s at 40 C. Main Characteristics The Tamson Filter Blocking Tendency Tester (TFBT) is a unique instrument designed to test distillate fuels including gas oil, gas turbine fuel, kerosine, diesel, biodiesel and biodiesel blends. It performs conform ASTM D2068 / IP 387 methods. The TFBT is microprocessor controlled and provides a simple user interface using a touch screen. This interface is exceptionally easy to use for selecting different tests, setting parameters and for calibration of the temperature and pressure sensors. The touch screen display provides the operator with test procedure information as well as indicating the selected test method, sample temperature, pressure, volume and the test result. A printer is integrated to provide a permanent record of the test parameters, results and a filterability graph. The software permits the operator to exactly set the test volume of 20ml/min even at the maximum pressure of 200kPa. This allows both specification testing and gravimetric tests to be carried out in conjunction with the appropriate filters and holders. The fuel sample is drawn from the fuel reservoir by the pump. The pressure and temperature of the fuel are continuously monitored while it is pumped through the specified filter into the waste container. The recorded pressure rise, or the volume of pumped sample that causes a specified pressure to be exceeded, are used by the microprocessor to calculate the test result. Standard tests use 300ml of fuel pumped at 20ml/min. Verification and re-calibration is simple and secure. Please contact Tamson for further information. Tamson Filter Blocking Tendency Filter Blocking Tendency Range Maximum pressure Power Size Voltage Weight 1.0 to 30 (low number is best) 200kPa 100 W 30x25x60 (LWH) V, 50-60Hz 10 kg New product TFBT REF 00T0942 (85-230V/50-60Hz) Filter Blocking Tendency 34

37 High Temperature Baths 35

38 2 High Temperature Baths 2.1 How to select the appropriate circulator? Temperature range Setting ( C) Stability Heating (W) Heaters Bath Volume (L) Opening bath (mm) Depth bath (mm) Pump pressure (mbar) Pump capacity Dimensions (LxWxH) Tamson Bracket Ambient..200 C 0.1 Better then 0.03K >185*(<186*422) *190 > max 7.5 max TC6B Ambient..200 C 0.1 Better then 0.03K * max 7.5 max 350*213*440 TC10B Ambient..200 C 0.1 Better then 0.02K * max 7.5 max 440*250*440 TC20B Ambient..200 C 0.1 Better then 0.02K * max 7.5 max 555*375*425 TC16 Ambient..250 C K * max 7.5 max 455*295*440 TC40 Ambient..250 C K * max 7.5 max 705*375*440 TC58 Ambient..250 C K * max 7.5 max 705*375*590 High Temperature Baths 36

39 High Temperature Baths 2.2 Tamson Bracket - TB A heating immersion circulator is available for various bath tanks up to a capacity of 50 liters and come equipped with a mounting bridge that fits onto all tanks with a maximum opening of 442 mm. The Tamson Bracket is based on the Tamson Thermostatic Unit (TTU) and can be used for heating or/and circulating purposes. The bath fluid is heated via a micro-processor controlled heating element. The bracket can be placed on a tank. The width of the bracket can be adjusted between 186 and 422 mm. Main Characteristics The set point of the TB can be set in steps of 0.1 C in the range of 0 C up to 200 C ( F). The accuracy of the display is displayed in 0.1 C. However, the controller has an internal accuracy of 0.01 C. Two decimal readout is also available via the RS232 and the free Tamcom software. Due to the self heating of the stirring mechanism, the minimum temperature lies approximately 5K above the ambient temperature. Tamson Bracket Range 200 C/ 392 F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.1 C Stability ± 0.03 K Heating 1100 W (1 heater) Bath volume Max 50 L Width bath > 186 mm < 422 mm Depth bath > 160 mm Length bath > 185 mm Height head 190 mm Pump (mbar) Max pressure 250 Pump (L/min) Max flow 7.5 Weight 4 kg REF 00T0380 (230V/50-60Hz) REF 00T0385 (115V/60Hz) Specification sheets available For options and spare parts, please see our section `TCB line Bracket 37

40 High Temperature Baths 2.3 Tamson Circulator - TCB Line Circulators offer many application possibilities, e.g. routine laboratory applications, temperature control of samples, incubations, dental applications, material testing, corrosion tests, tempering of cultures as well as temperature testing of food and luxury articles. The TCB baths can be used as circulator or as a water/oil bath. Main Characteristics The set point can be set in steps of 0.1 in the range from 0 C up to 200 C ( F). The accuracy on the display is displayed in 0.1 C. However, the controller has an internal accuracy of 0.01 C. Two decimal readout is also available via the RS232 and the free Tamcom software. Due to the self heating of the stirring mechanism and when using a top lid, the minimum temperature lies approximately 5K above the ambient temperature. When using the standard built-in cooling coil the minimum operating temperature lies approximately 5K above the temperature of the cooling liquid. In general the minimum temperature lies around 10 C. Lower temperatures generate problems with built up of condensate in the inner insulation of the bath. TCB Line TC6B TC10B TC20B Range 200 C/ 392 F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.1 C Stability ± Better then 0.02 K Heating 1100 W (1 heater) 1100 W 1550 W (1 heater) Bath volume 6 L 10 L 20 L Opening bath (round edge) 148 * 120 mm 185 * 200 mm 300 * 320mm Depth bath 150 mm 150 mm 150 mm Pump (mbar) Max pressure 300 Pump (L/min) Max flow 7 Dimension LxWxH 350 x 213 x 440 mm 440 x 250 x 440 mm 555 x 375 x 425 mm Weight 8 kg 11 kg 13 kg TC6B REF 00T0030 (230V/50-60Hz) REF 00T0035 (115V/60Hz) TC10B REF 00T0150 (230V/50-60Hz) REF 00T0155 (115V/60Hz) TC20B REF 00T0160 (230V/50-60Hz) REF 00T0165 (115V/60Hz) TC6B TC10B TC20B 38

41 High Temperature Baths Options TB TC6 B TC1 0 B TC2 0 B REF 02T3025 RS232 serial communication port REF 25T0253 Heater 1550 W REF 03T0016 Leveling platform TC6B REF 03T0017 Leveling platform TC10B REF 03T0031 Leveling platform TC20B REF 00T0050 TLC10-3 external cooler 230V/50Hz REF 00T V/60Hz REF 00T V/60Hz Spare parts V /50-6 0Hz (1 1 5V-6 0Hz o n req ue st) TB TC6 B TC1 0 B TC2 0 B REF 25T1343 Capacitor 2uF REF 25T1295 Motor 30 W REF 25T0251 Heater 1100 W REF 25T0253 Heater 1550 W REF 25T2310 PT-100 sensor REF 06T0496 PCB TC bath REF 24T8545 Main switch REF 28T3902 Front foil TTU-B REF 24T8581 Safety cut-out thermostat REF 28T3022 K1S controller REF 24T8081 Motor fuse 0.3 Amp Specification sheets available TC6B TC6B TC10B TC20B 39

42 High Temperature Baths 2.4 Tamson Circulator TC Line The working temperature range offers many possibilities, e.g. routine applications, temperature control of samples, incubations, dental applications, material testing, corrosion tests, tempering of cultures as well as temperature testing of food and luxury articles. The TC baths are used for precise temperature control. They can be used as circulator or/and water/oil bath. The TC16 can be used for ASTM D70 purposes. Main Characteristics The insulation of the bath and electronic design result in a very stable working temperature of ±0.02K for the TC baths. The set point can be set in steps of 0.1 in the range form 0 C up to 250 C ( F). The accuracy on the display is displayed in 0.1 C. However, the controller has an internal accuracy of 0.01 C. Two decimal readout is also available via the RS232 and the free Tamcom software. Due to the self heating of the stirring mechanism and when using a top lid, the minimum temperature lies approximately 5K above the ambient temperature. When using the standard built-in cooling coil the minimum temperature lies approximately 5K above the temperature of the cooling liquid. In general the minimum temperature lies around 10 C. Lower temperatures generate problems with built up of condensate in the inner insulation of the bath. TC Line TC16 TC40 TC58 Range 250 C/ 482 F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.1 C Stability ± 0.02 K Heating 1200 W 2700 W 2700 W Bath volume 16 L 40 L 58 L Opening bath 180 * 210 MM 420 * 275 mm 420 * 275 mm Depth bath 200 mm 200 mm 300 mm Pump (mbar) Max pressure 300 (optional 1 mbar) Pump (L/min) Max flow 7.5 (optional 16) Dimension LxWxH 455 x 294 x 440 mm 705 x 375 x 440 mm 705 x 375 x 590 mm Weight 21 kg 30 kg 35 kg TC16 REF 00T0671 (230V/50-60Hz) REF 00T0861 (115V/60Hz) TC40 REF 00T0681 (230V/50-60Hz) REF 00T0851 (115V/60Hz) TC58 REF 00T0691 (230V/50-60Hz) REF 00T0881 (115V/60Hz) TC16 TC40 TC58 40

43 High Temperature Baths Options TC1 6 TC4 0 TC5 8 REF 02T3025 RS232 serial communication port REF 00T0253 Suction/pressure pump REF 24T0392 Performance pump (16L/min) REF 25T0190 Additional boost heater (1500W) REF 07T0210 Leveling platform TC16 REF 07T0211 Leveling platform TC40 REF 07T0212 Leveling platform TC58 REF 03T2270 Lid leveling platform REF 03T3200 Gabled lid REF 03T2210 Gabled lid + leveling platform REF 00T0254 Top lid cover with 1 set of rings REF 00T0255 Top lid cover with 2 sets of 9 rings REF 00T0256 Top lid cover with 6 sets of 6 rings REF 00T0050 REF 00T0565 TLC10-3 external cooler 230V/50Hz REF 00T V/60Hz REF 00T V/60Hz TLC15-5 external cooler 230V/50Hz REF 00T V/60Hz REF 00T V/60Hz On request Remote PT100 Spare parts 2 3 0V / Hz (1 1 5 V-6 0 Hz o n reque st) TC1 6 TC4 0 TC5 8 REF 25T1242 Fan REF 04T0035 Pump complete REF 24T8080 Motor fuse REF 24T3300 Motor capacitor REF 06T0496 PCB TC bath REF 25T0170 Heater 200/1000 W REF 25T0190 Boost heater 1500 W REF 24T8540 Main switch REF 24T8581 Safety cut-out thermostat REF 28T3022 K1S Controller REF 25T2310 PT-100 sensor Buy online TC16 TC40 TC58 41

44 Low Temperature Baths 42

45 3 Low Temperature Baths 3.1 How to select the appropriate cooler? Temperature range Setting ( C) Stability Heating (WATT) Heaters Bath Volume (L) Opening bath (mm) Depth bath (mm) Pump pressure (mbar) Pump capacity (L/min) Heat removal ºC (WATT) Dimensions (LxWxH) TLC C Optional C 0.01 Better than 0.05K * max @ *195*410 TLC C Optional C 0.01 Better than 0.05K * max @ *26*565 TLC C Optional C 0.01 Better than 0.05K * max @ *265*565 TLC C Optional C 0.1 Better than 0.05K * max 810*460*770 TLC C..ambient 0.1 Better than 0.05K * max *460*770 TLC80-14DP -82 C..ambient 0.1 Better than 0.05K * max *496*1175 TLC C..ambient 0.1 Better than 0.05K * max 810*460*770 Low Temperature 43

46 Low Temperature Baths 3.2 Tamson Cooling Circulators TLC Line The TLC-10 has been developed to be used as general purpose circulator and it can be used in various applications where cooling is needed. Experiments, refractometers, rotary-evaporators, distillation units, water baths, viscosity baths, flashpoint tester all are applications for which the TLC-10 can be used. Main Characteristics The apparatus holds a small bath containing 3.5 litres and the filling opening measures 40 x 120 mm. Due to its special design the system is extremely quiet, compact and saves costly laboratory space. Readout is in degrees C or in F. The bath comes standard with RS232 communication and when using the free software tool Tamcom, it provides temperature logging or a predefined temperature set point curve. A pump provides circulation in the bath or via an external circuit. The pump offers 7 litres per minute with a maximum counter pressure of 300 mbar. Range C* / F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.01 C Stability ± Better than 0.1 K Heating 1100 W Bath volume 3.5 L Opening bath 40 * 120 mm Depth bath 150 mm Pump (mbar) Max pressure 300 Pump (L/min) Max flow 7 Dimension 360 x 228 x 552 mm (LxWxH) Weight 18 kg Heat removal See 3.1 TLC-10 Cooling circulator All product details at * On request the TLC10-3 can have a working range from C TLC10-3 REF 00T0050 (230V/50Hz) REF 00T0051 (230V/60Hz) REF 00T0052 (115V/60Hz) For options and spare parts, please see section `TC15-5 TC30-5 TLC10 44

47 Low Temperature Baths 3.3 Tamson Cooling Circulators TLC Line The TLC15-5 and TLC30-5 have been developed to be used as general purpose circulator and they can be used in various applications where cooling is needed. Examples are experiments, refractometers, rotary-evaporators, distillation units, water baths, viscosity baths, flashpoint testers, foaming tests and ductility tests. Main Characteristics The apparatus holds a small bath containing 5 litres and the filling opening measures 85 x 150 mm. Due to its special design the system is extremely quiet, compact and saves costly laboratory space. Readout is in degrees C or in F. A pump provides circulation in the bath or via an external circuit. The pump offers 7 litres per minute with a maximum counter pressure of 300 mbar. TLC15-5 TLC15-5 TLC30-5 Range C*/ F C*/ F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.01 C Stability ± Better than 0.1 K Heating 1100 W Bath volume 5 L Opening bath 85 * 150 mm Depth bath 150 mm Pump (mbar) Max pressure 300 Pump (L/min) Max flow 7 Dimension LxWxH 420 X 265 X 565 mm Weight 30 kg Heat removal See 3.1 * On request the TLC15-5 can have a working range from C * On request the TLC30-5 can have a working range from C TLC15-5 REF 00T0565 (230V/50Hz) REF 00T0567 (230V/60Hz) REF 00T0570 (115V/60Hz) TLC30-5 REF 00T0555 (230V/50Hz) REF 00T0562 (230V/60Hz) REF 00T0560 (115V/60Hz) TLC15 TLC30 45

48 Low Temperature Baths Options TLC10-3 TLC15-5 TLC30-5 On request Remote PT100 REF 04T0225 Performance Pump REF 04T0228 Performance Pump Spare parts 230V/50Hz (115V-60Hz / 230V-60HZ on request) TLC10-3 TLC15-5 TLC30-5 REF 25T1295 Motor 30 W REF 25T1343 Capacitor 2uF REF 25T0251 Heater 1100 W REF 24T8081 Motor fuse 0.3 Amp. REF 24T8581 Safety cut-out thermostat REF 24T8545 Mains switch REF 24T8540 Mains switch REF 25T2310 PT-100 sensor REF 25T2320 PT-100 sensor REF 06T0514 Print TLC-TMC70 Power Board REF 06T0513 Print TLC-TMC70 up-display REF 04T0220 Standard pump complete REF 04T0226 Standard pump complete All product details at TLC15 TLC30 46

49 Low Temperature Baths 3.4 Tamson Cooling Circulators TLC Line The TLC40-14 cooling circulator can be used for multiple heat removal purposes such as replacement of tap water, fast cool down, flashpoint, distillation, density or cloud and pour point testing. Also this unit can be used to cool down water baths and viscosity baths which have a large bath volume. TLC80-14 and TLC90-14 baths can be used for general low temperature use, but shows excellent heat removal performance i.e. combination cloud and pour point tests, cold filter plugging point tests, or pour point tests. Main Characteristics The apparatus holds a bath containing 14 litres and the filling opening measures 240 x 170 mm. Due to its special design the system is extremely quiet, compact and saves costly laboratory space. With the TLC40-14 the minimum temperature which can be reached is -40 C. With the TLC80-14 the minimum temperature which can be reached is -80 C. At -80 C the heat removal capacity is 300 Watts. With the TLC90-14 the minimum temperature which can be reached is -90 C. Readout is in degrees C or in F. A pump provides circulation in the bath or pumps the flow to an external circuit. The pump offers 7 litres per minute with a maximum counter pressure of 300 mbar. Optional is a performance pump which offers 16 litres per minute. TLC40-14 TLC40-14 TLC80-14 TLC90-14 Range C*/ F C/ F C/ F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.1 C Stability ± Better than 0.05 K Heating 1550 W Bath volume L Opening bath 240 * 170 mm Depth bath 150 mm Pump (mbar) Max pressure 300 (optional 1 bar) Pump (L/min) Max flow 7 (optional 16) Max flow 10 (optional 16) Max flow 10 (optional 16) Dimension LxWxH 810 x 460 x 770 mm (LxWxH) Weight 65 kg 80 kg 80 kg Heat removal See 3.1 * On request the TLC40-14 can have an optional working range from C TLC40-14 REF 00T0520 (230V/50Hz) REF 00T0522 (230V/60Hz) REF 00T0525 (115V/60Hz) TLC80-14 REF 00T0530 (230V/50Hz) REF 00T0532 (230V/60Hz) REF 00T0535 (115V/60Hz) TLC90-14 REF 00T0580 (230V/50Hz) REF 00T0585 (230V/60Hz) REF 00T0590 (115V/60Hz) For options and spare parts, please see section TLC80-14DP TLC40 TLC80 TLC90 47

50 Low Temperature Baths 3.5 Tamson Cooling Circulators TLC Line The TLC80-14DP can be used for general low temperature use but shows excellent heat removal performance i.e. combination with cloud and pour point tests, cold filter plugging point tests and pour point tests. Main Characteristics The apparatus holds a bath containing 14 litres and the filling opening measures 240 x 170 mm. Due to its special design the system is extremely quiet. The minimum temperature which can be reached is minus 82 C. At this low temperature the heat removal capacity lies around 150 watts. The TLC80-14DP is especially developed to cool down several instruments in a row. The Tamson manifold can be used for this purpose. Readout is in degrees C or in F. A pump provides circulation in the bath or via an external circuit. The pump offers 7 litres per minute with a maximum counter pressure of 300 mbar. A single switch can turn the apparatus into economy mode when the full cooling capacity is not needed (e.g. overnight). Range C / F Reading Standard C, F on request Used materials inside bath Stainless Steel 304, PTFE Setting ± 0.1 C Stability ± Better than 0.05 K Heating 1550 W Bath volume L Opening bath 240 * 170 mm Depth bath 150 mm Pump (Bar) Max pressure 0,3 (Optional 1Bar) Pump (L/min) Max flow 10 (Optional 16) Dimension 810 x 490 x 1150 mm (LxWxH) Weight 140 kg Heat removal See 3.1 TLC80-14DP REF 00T0540 (230V/50Hz) TLC80-14DP Reliable cooling TLC80-14DP 48

51 Low Temperature Baths Options TLC40-14 TLC80-14 TLC90-14 TLC80-14DP REF 02T3025 RS232 serial communication REF 24T0392 Performance pump (16 L/min) REF 00T0635 Manifold On request Remote PT100 Spare parts 230V/50Hz (115V-60Hz/230V-60HZ on request) TLC40-14 TLC80-14 TLC90-14 TLC80-14DP REF 25T1290 Motor for pump REF 25T1343 Capacitor 2uF REF 25T0253 Heater 1550 W REF 24T8081 Motor fuse 0.3 Amp. REF 06T0475 Mains board with filer and relay (PCB TTU) REF 24T8581 Safety cut-out thermostat REF 24T8541 Mains switch REF 25T2320 PT-100 sensor REF 28T3022 K1S controller REF 04T0025 Pump complete We keep it cool TLC80-14DP 49

52 Low Temperature Baths 3.6 New Tamson Cooling Circulators In the first quarter two new low temperature circulators will be introduced. New TLC80 The new TLC80-09 will replace the current TLC80-14 and can be used for general low temperature use and shows excellent heat removal performance in combination with cloud and pour point, cold filter plugging point, or pour point tests. The apparatus with small dimensions holds a bath containing 9 litres and the filling opening measures 60 x 160 mm. Due to its special design the system is extremely quiet, compact and saves costly laboratory space. With the TLC80-9 the minimum temperature which can be reached is -80 C. At -80 C the heat removal capacity is 300 Watts. Different pumps are offered to cover a flow/pressure range between 5ltrs/300mBar up to 16ltr/1Bar. Available in Q2 of New TCC The TCC80-1, Tamson Cool Cube, is the introduction to our New TCC new generation of chillers for routine cooling applications within the laboratory and industry. The TCC is a circulator developed for closed systems. The unit cools down to -80C within 45 minutes. The compact dimensions of 470x300x600mm are unique, and save a costly laboratory space. The TCC80 is equipped with a pump offering 5ltrs max@ 300mBar, to provide circulation to an external apparatus like any automated cold property testing device. The TCC80 has a filling lid and can be used with methanol, ethanol or silicon thermo fluid. The filling port and access to the pump are easily accessible. Special fans ensure very quite (low noise) operation. Available in Q2 of If you are interested in the new TLC80-9 or TCC-1, please contact us via sales@tamson.com. New TLC80 New products TLC80 TCC 50

53 Low Temperature Baths 3.7 Tamson Immersion Coolers KV Line The Tamson KV40 and KV80 are portable, compact immersion coolers that provides fast, continuous cooling down to 40 C or -80 C. It can be used in conjunction with an immersion heating circulator if temperature control is necessary. The KV series provides efficient cooling capacity and it eliminates constant cold trap hassles and the need for chemical refrigerants such as dry ice and acetone mixtures. The KV line can be used as or with rotary evaporator cold-trap condensers, cooling open reservoirs, vapour and solvent trapping. It can also be used for or with the Tamson TLV25, the Tamson circulators / water baths and for the replacement of tap water. KV80 Main Characteristics The KV40 and KV80 are designed for heat extraction from fluid in viscometer baths. The combination of the KV40 and the low temperature viscosity bath TLV25, allows stable viscosity measurements at low temperatures down to -40 C. The KV80 allows measurements to -80 C. Temperature stability of the TLV25 + KV40/KV80 combination supersedes ASTM D445 requirements. The cooling probe of the system is formed by a nickel plated cupper coil at the top of a flexible hose. This probe can be immersed in fluid which has to be cooled down. The KV40 and KV80 can be switched off via its main switch on the side panel. KV40 KV80 Minimum Probe temp -40 C/-40 F -80 C/-112 F Body Steel. PET Stainless Steel, PET Hose length 2500 mm Probe length 190 mm Probe diameter 47 mm Dimension (L x W x H) 390 x 310 x 360 mm 560 x 450 x 500 mm Weight 25 kg 60 kg Power 600 Watt 1200 Watt KV40 REF 00T0212 (230V/50Hz) REF 00T212A (230V/60Hz) REF 00T0259 (115V/60Hz) KV80 REF 00T0216 (230V/50Hz) REF 00T216A (230V/60Hz) REF 00T0260 (115V/60Hz) KV40 KV80 51

54 Accessories 52

55 4 Accessories 4.1 Viscometers For the determination of kinematic viscosity of transparent and opaque Newtonian liquids according to ASTM D446, ISO 3104, IP 71 and BS 188. Viscometer tubes with calibration certificate UBBELOHDE VISCOMETER for transparent and opaque liquids REF 25T0814 Size number 0 Norm. Constant Range from 0.3 to 1 cst REF 25T0815 Size number 0C Norm. Constant Range from 0.6 to 3 cst REF 25T0816 Size number 0B Norm. Constant Range from 1 to 5 cst REF 25T0817 Size number 1 Norm. Constant 0.01 Range from 2 to 10 cst REF 25T0818 Size number 1C Norm. Constant 0.03 Range from 6 to 30 cst REF 25T0819 Size number 1B Norm. Constant 0.05 Range from 10 to 50 cst REF 25T0820 Size number 2 Norm. Constant 0.1 Range from 20 to 100 cst REF 25T0821 Size number 2C Norm. Constant 0.3 Range from 60 to 300 cst REF 25T0822 Size number 2B Norm. Constant 0.5 Range from 100 to 500 cst REF 25T0823 Size number 3 Norm. Constant 1.0 Range from 200 to 1000 cst REF 25T0824 Size number 3C Norm. Constant 3.0 Range from 600 to 3000 cst REF 25T0825 Size number 3B Norm. Constant 5.0 Range from 1000 to 5000 cst REF 25T0826 Size number 4 Norm. Constant 10 Range from 2000 to cst REF 25T0827 Size number 4C Norm. Constant 30 Range from 6000 to cst REF 25T0828 Size number 4B Norm. Constant 50 Range from to cst REF 25T0829 Size number 5 Norm. Constant 10 Range from to cst CANNON-FENSKE ROUTINE VISCOMETER for transparent liquids REF 25T0790 Size number 25 Norm. Constant Range from 0.4 to 2 cst REF 25T0791 Size number 50 Norm. Constant Range from 0.8 to 4 cst REF 25T0792 Size number 75 Norm. Constant Range from 1.6 to 8 cst REF 25T0793 Size number 100 Norm. Constant Range from 3 to 15 cst REF 25T0794 Size number 150 Norm. Constant Range from 7 to 35 cst REF 25T0795 Size number 200 Norm. Constant 0.1 Range from 20 to 100 cst REF 25T0796 Size number 300 Norm. Constant 0.25 Range from 50 to 200 cst REF 25T0797 Size number 350 Norm. Constant 0.5 Range from 100 to 500 cst REF 25T0798 Size number 400 Norm. Constant 1.2 Range from 240 to 1200 cst REF 25T0799 Size number 450 Norm. Constant 2.5 Range from 500 to 2500 cst REF 25T0800 Size number 500 Norm. Constant 8 Range from 1600 to 8000 cst REF 25T0801 Size number 600 Norm. Constant 20 Range from 4000 to cst REF 25T0842 Size number 650 Norm. Constant 50 Range from to cst REF 25T0843 Size number 700 Norm. Constant 100 Range from to cst For Viscometer Holders, please see section Viscosity Accessories Viscometers 53

56 Accessories CANNON-FENSKE REVERSE FLOW VISCOMETER for opaque and transparent liquids REF 25T0802 Size number 25 Norm. Constant Range from 0.4 to 2 cst REF 25T0803 Size number 50 Norm. Constant Range from 0.8 to 4 cst REF 25T0804 Size number 75 Norm. Constant Range from 1.6 to 8 cst REF 25T0805 Size number 100 Norm. Constant Range from 3 to 15 cst REF 25T0806 Size number 150 Norm. Constant Range from 7 to 35 cst REF 25T0807 Size number 200 Norm. Constant 0.1 Range from 20 to 100 cst REF 25T0808 Size number 300 Norm. Constant 0.25 Range from 50 to 200 cst REF 25T0809 Size number 350 Norm. Constant 0.5 Range from 100 to 500 cst REF 25T0810 Size number 400 Norm. Constant 1.2 Range from 240 to 1200 cst REF 25T0811 Size number 450 Norm. Constant 2.5 Range from 500 to 2500 cst REF 25T0812 Size number 500 Norm. Constant 8 Range from 1600 to 8000 cst REF 25T0813 Size number 600 Norm. Constant 20 Range from 4000 to cst REF 25T0850 Size number 650 Norm. Constant 50 Range from to cst REF 25T0851 Size number 700 Norm. Constant 100 Range from to cst BS/IP/RF U-tube VISCOMETER for opaque and transparent liquids REF 25T1030 Size number 1 Norm. Constant Range from 0.6 to 3 cst REF 25T1031 Size number 2 Norm. Constant 0.01 Range from 2 to 10 cst REF 25T1032 Size number 3 Norm. Constant 0.03 Range from 6 to 30 cst REF 25T1033 Size number 4 Norm. Constant 0.1 Range from 20 to 100 cst REF 25T1034 Size number 5 Norm. Constant 0.3 Range from 60 to 300 cst REF 25T1035 Size number 6 Norm. Constant 1.0 Range from 200 to 1000 cst REF 25T1036 Size number 7 Norm. Constant 3.0 Range from 600 to 3000 cst REF 25T1037 Size number 8 Norm. Constant 10 Range from 2000 to cst REF 25T1038 Size number 9 Norm. Constant 30 Range from 6000 to cst REF 25T1039 Size number 10 Norm. Constant 100 Range from to cst REF 25T1040 Size number 11 Norm. Constant 300 Range from to cst BS/IP/SL U-tube VISCOMETER for transparent liquids REF 25T0831 Size number 1A Norm. Constant 0.03 Range from 6 to 30 cst REF 25T0830 Size number 1 Norm. Constant 0.01 Range from 3.5 to 10 cst REF 25T0833 Size number 2A Norm. Constant 0.3 Range from 60 to 300 cst REF 25T0832 Size number 2 Norm. Constant 0.1 Range from 20 to 100 cst REF 25T0835 Size number 3A Norm. Constant 3.0 Range from 600 to 3000 cst REF 25T0834 Size number 3 Norm. Constant 1.0 Range from 200 to 1000 cst REF 25T0837 Size number 4A Norm. Constant 30 Range from 6000 to cst REF 25T0836 Size number 4 Norm. Constant 10 Range from 2000 to cst REF 25T0838 Size number 5 Norm. Constant 100 Range from to cst For Viscometer Holders, please see section Viscosity Accessories Viscometers 54

57 Accessories BS/IP/SL(S) VISCOMETER for transparent liquids REF 25T1013 Size number 1 Norm. Constant Range from 1.05 cst min REF 25T1014 Size number 2 Norm. Constant Range from 2.1 to 3 cst REF 25T1015 Size number 3 Norm. Constant 0.01 Range from 3.8 to 10 cst REF 25T1016 Size number 4 Norm. Constant 0.03 Range from 6 to 30 cst REF 25T1017 Size number 5 Norm. Constant 0.1 Range from 20 to 100 cst REF 25T1018 Size number 6 Norm. Constant 0.3 Range from 60 to 300 cst REF 25T1019 Size number 7 Norm. Constant 1.0 Range from 200 to 1000 cst REF 25T1020 Size number 8 Norm. Constant 3.0 Range from 600 to 2000 cst REF 25T1021 Size number 9 Norm. Constant 10.0 Range from 2000 to cst BS/U-tube VISCOMETER for transparent liquids REF 25T1001 Size number A Norm. Constant Range from 0.9 to 3 cst REF 25T1002 Size number B Norm. Constant 0.01 Range from 2.0 to 10 cst REF 25T1003 Size number C Norm. Constant 0.03 Range from 6 to 30 cst REF 25T1004 Size number D Norm. Constant 0.1 Range from 20 to 100 cst REF 25T1005 Size number E Norm. Constant 0.3 Range from 60 to 300 cst REF 25T1006 Size number F Norm. Constant 1.0 Range from 200 to 1000 cst REF 25T1007 Size number G Norm. Constant 3.0 Range from 600 to 3000 cst REF 25T1008 Size number H Norm. Constant 10.0 Range from 2000 to cst BS/U/M-Miniature VISCOMETER for transparent liquids REF 25T1022 Size number M1 Norm. Constant Range from 0.2 to 1 cst REF 25T1023 Size number M2 Norm. Constant Range from 1 to 5 cst REF 25T1024 Size number M3 Norm. Constant Range from 3 to 15 cst REF 25T1025 Size number M4 Norm. Constant 0.04 Range from 8 to 40 cst REF 25T1026 Size number M5 Norm. Constant 0.1 Range from 20 to 100 cst BS/IP/MSL VISCOMETER for transparent liquids REF 25T0750 Size number 1 Norm. Constant Range from 0.6 to 3 cst REF 25T0751 Size number 2 Norm. Constant 0.01 Range from 2.0 to 10 cst REF 25T0752 Size number 3 Norm. Constant 0.03 Range from 6 to 30 cst REF 25T0753 Size number 4 Norm. Constant 0.1 Range from 20 to 100 cst REF 25T0754 Size number 5 Norm. Constant 0.3 Range from 60 to 300 cst REF 25T0755 Size number 6 Norm. Constant 1.0 Range from 200 to 1000 cst REF 25T0756 Size number 7 Norm. Constant 3.0 Range from 600 to 3000 cst For Viscometer Holders, please see section Viscosity Accessories Viscometers 55

58 Accessories SIL VISCOMETER for transparent liquids REF 25T0882 Size number 0C Norm. Constant Range from 0.9 to 3 cst REF 25T0883 Size number 1 Norm. Constant 0.01 Range from 2.0 to 10 cst REF 25T0884 Size number 1C Norm. Constant 0.03 Range from 6 to 30 cst REF 25T0885 Size number 2 Norm. Constant 0.1 Range from 20 to 100 cst REF 25T0886 Size number 2C Norm. Constant 0.3 Range from 60 to 300 cst REF 25T0887 Size number 3 Norm. Constant 1.0 Range from 200 to 1000 cst REF 25T0888 Size number 3C Norm. Constant 3.0 Range from 600 to 3000 cst REF 25T0889 Size number 4 Norm. Constant 10.0 Range from 2000 to cst Zeitfuchs Cross-Arm VISCOMETER for opaque and transparent liquids REF 25T1041 Size number 1 Norm. Constant Range from 0.6 to 3 cst REF 25T0890 Size number 2 Norm. Constant 0.01 Range from 2 to 10 cst REF 25T0891 Size number 3 Norm. Constant 0.03 Range from 6 to 30 cst REF 25T0893 Size number 4 Norm. Constant 0.10 Range from 20 to 100 cst REF 25T0894 Size number 5 Norm. Constant 0.3 Range from 60 to 300 cst REF 25T0895 Size number 6 Norm. Constant 1.0 Range from 200 to 1000 cst REF 25T0896 Size number 7 Norm. Constant 3.0 Range from 600 to 3000 cst REF 25T0897 Size number 8 Norm. Constant 10.0 Range from 2000 to cst REF 25T0898 Size number 9 Norm. Constant 30.0 Range from 6000 to cst REF 25T0899 Size number 10 Norm. Constant Range from to cst For Viscometer Holders, please see section Viscosity Accessories Viscometers are delivered with a calibration certificate. Viscometers can be delivered with ISO certificate under UKAS. Then a P should be added to the reference number, e.g. 25T0814P. Other ASTM D446 viscometers on request. See our web shop Viscometers 56

59 Accessories TV2000AKV VISCOMETERS for transparent and opaque liquids. The glass capillary viscometers supplied for the TV2000AKV are completely manufactured according to ASTM D 446 and IP 71, however the timing marks have been omitted for the infra red sensors of the electronic detection system. The tubes are further more precisely manufactured than the standard norm requires. This guarantees optimal measuring results. The tubes will be supplied with a factory calibration certificate, stating the viscometer number and constant of the viscometer. In order to use the TV2000AKV you will need the viscometers which are only supplied by Tamson. The following glass capillary viscometers are available: UBBELOHDE AKV VISCOMETER for transparent liquids REF 25T0766 Size number 0 Norm. Constant Range from 0.3 to 1 cst REF 25T0767 Size number 0C Norm. Constant Range from 0.6 to 3 cst REF 25T0768 Size number 0B Norm. Constant Range from 1 to 5 cst REF 25T0769 Size number 1 Norm. Constant 0.01 Range from 2 to 10 cst REF 25T0770 Size number 1C Norm. Constant 0.03 Range from 6 to 30 cst REF 25T0771 Size number 1B Norm. Constant 0.05 Range from 10 to 50 cst REF 25T0772 Size number 2 Norm. Constant 0.1 Range from 20 to 100 cst REF 25T0773 Size number 2C Norm. Constant 0.3 Range from 60 to 300 cst REF 25T0774 Size number 2B Norm. Constant 0.5 Range from 100 to 500 cst REF 25T0775 Size number 3 Norm. Constant 1.0 Range from 200 to 1000 cst REF 25T0776 Size number 3C Norm. Constant 3.0 Range from 600 to 3000 cst REF 25T0777 Size number 3B Norm. Constant 5.0 Range from 1000 to 5000 cst REF 25T0778 Size number 4 Norm. Constant 10.0 Range from 2000 to cst CANNON FENSKE ROUTINE VISCOMETER for transparent liquids REF 25T0779 Size number 25 Norm. Constant Range from 0.4 to 2 cst REF 25T0780 Size number 50 Norm. Constant Range from 0.8 to 4 cst REF 25T0781 Size number 75 Norm. Constant Range from 1.6 to 8 cst REF 25T0782 Size number 100 Norm. Constant Range from 3 to 15 cst REF 25T0783 Size number 150 Norm. Constant Range from 7 to 35 cst REF 25T0784 Size number 200 Norm. Constant 0.1 Range from 20 to 100 cst REF 25T0785 Size number 300 Norm. Constant 0.25 Range from 50 to 200 cst REF 25T0786 Size number 350 Norm. Constant 0.5 Range from 100 to 500 cst REF 25T0787 Size number 400 Norm. Constant 1.2 Range from 100 to 500 cst REF 25T0788 Size number 450 Norm. Constant 2.5 Range from 200 to 1000 cst REF 25T0789 Size number 500 Norm. Constant 8 Range from 600 to 3000 cst On request Size number 600 Norm. Constant 20 Range from 2000 to cst Buy capillary online Viscometers 57

60 Accessories Viscometer Tubes with calibration certificate. For measurement of viscosity of highly viscous materials according to ASTM D2171. CANNON MANNING VACUUM VISCOMETER REF 25T1045 Size number 4 Range from Viscosity range, poise REF 25T1046 Size number 5 Range from Viscosity range, poise REF 25T1047 Size number 6 Range from Viscosity range, poise REF 25T1048 Size number 7 Range from Viscosity range, poise REF 25T1049 Size number 8 Range from Viscosity range, poise REF 25T1050 Size number 9 Range from Viscosity range, poise REF 25T1051 Size number 10 Range from Viscosity range, poise REF 25T1052 Size number 11 Range from Viscosity range, poise REF 25T1053 Size number 12 Range from Viscosity range, poise REF 25T1054 Size number 13 Range from Viscosity range, poise REF 25T1055 Size number 14 Range from Viscosity range, poise ASPHALT INSTITUTE VACUUM VISCOMETER REF 25T3001 Size number 25 Range from Viscosity range, poise REF 25T3002 Size number 50 Range from Viscosity range, poise REF 25T3003 Size number 100 Range from Viscosity range, poise REF 25T3004 Size number 200 Range from Viscosity range, poise REF 25T3005 Size number 400R Range from Viscosity range, poise REF 25T3006 Size number 800R Range from Viscosity range, poise MODIFIED KOPPERS VACUUM VISCOMETER REF 25T3010 Size number 25 Range from Viscosity range, poise REF 25T3011 Size number 50 Range from Viscosity range, poise REF 25T3012 Size number 100 Range from Viscosity range, poise REF 25T3013 Size number 200 Range from Viscosity range, poise REF 25T3014 Size number 400 Range from Viscosity range, poise For Viscometer Holders, please see section Viscosity Accessories Application For the determination of kinematic viscosity of transparant Newtonian liquids according to ASTM D2162. MASTER VISCOMETER REF 25T0757 Master Ubbelohde viscometer (uncalibrated) ASTM D2162 REF 25T0758 Master Cannon Fenske viscometer (uncalibrated) ASTM D2162 For Viscometer Holders, please see section Viscosity Accessories Viscometers 58

61 Accessories Application For the determination of kinematic viscosity of transparant Newtonian liquids according to ASTM D7279. HOUILLON VISCOMETER for transparent liquids REF 25T0873 Norm. Constant 0.05 Range from to cst REF 25T0874 Norm. Constant 0.07 Range from to cst REF 25T0875 Norm. Constant 0.10 Range from to cst REF 25T0876 Norm. Constant 0.20 Range from to cst REF 25T0877 Norm. Constant 0.30 Range from to cst REF 25T0878 Norm. Constant 0.50 Range from to cst REF 25T0879 Norm. Constant 0.70 Range from to cst REF 25T0880 Norm. Constant 1.00 Range from to cst REF 25T0881 Norm. Constant 1.20 Range from to cst REF 25T1056 Norm. Constant 1.50 Range from to cst REF 25T1057 Norm. Constant 2.00 Range from to cst REF 25T1058 Norm. Constant 3.00 Range from to cst REF 25T1059 Norm. Constant 5.00 Range from to cst REF 25T1060 Norm. Constant 7.00 Range from to cst REF 25T1062 Norm. Constant 8.50 Range from to cst REF 25T1063 Norm. Constant Range from to cst REF 25T1064 Norm. Constant Range from to cst Application For the determination of kinematic viscosity liquids according to Baume Vigneron. BAUME VIGNERON VISCOMETER for transparent liquids REF 25T0852 REF 25T0853 REF 25T0854 REF 25T0855 REF 25T0856 REF 25T0857 REF 25T0858 REF 25T0859 REF 25T0860 REF 25T0861 REF 25T0862 REF 25T0863 REF 25T0864 REF 25T0865 REF 25T0866 REF 25T0867 REF 25T0868 REF 25T0869 REF 25T0870 REF 25T0871 REF 25T0872 Viscosity Range at 0.63 cst Viscosity Range at 1 cst Viscosity Range at 1.6 cst Viscosity Range at 2.5 cst Viscosity Range at 4 cst Viscosity Range at 6.3 cst Viscosity Range at 10 cst Viscosity Range at 15 cst Viscosity Range at 25 cst Viscosity Range at 40 cst Viscosity Range at 63 cst Viscosity Range at 100 cst Viscosity Range at 180 cst Viscosity Range at 250 cst Viscosity Range at 400 cst Viscosity Range at 630 cst Viscosity Range at 1000 cst Viscosity Range at 1600 cst Viscosity Range at 2500 cst Viscosity Range at 4000 cst Viscosity Range at 6300 cst Viscometers 59

62 Accessories 4.2 Viscosity Accessories VISCOMETER HOLDERS A high quality holder/support for use with manual glass capillary viscometers. Main Characteristics Insulated handle, easy to grab at high working temperatures Stainless steel Ring to hang out ± 265 mm Smart design prevents viscometer from falling out of holder Viscometer will not move when apply vacuum to the viscometer Detailed information Viscometer Holders REFERENCES ASTM D446, IP71, BS88 REF 10T6001 REF 10T6040 REF 10T6061 REF 10T6071 REF 10T6321 REF 10T6051 REF 10T6323 REF 10T6324 REF 10T6325 REF 10T6326 REF 10T6327 Viscometer holder Ubbelhode Viscometer holder Pinkevitch transparent D446, 269 mm Viscometer holder Cannon-Fenske Routine Viscometer holder Cannon-Fenske Opaque/Reverse Flow Viscometer holder BS/U-tube Transparent/Routine Viscometer holder BS/IP/RF U-Tube Opaque Viscometer Holder BS/IP/SL Viscometer Holder BS/IP/SL(S) Viscometer Holder BS/U/M Viscometer Holder BS/IP/MSL Viscometer Holder Zeitfuchs Cross Arm REFERENCES RUSSIAN VISCOMETERS REF 10T6050 Russian Viscometer holder Russian Viscometers (ВПЖ-2) like Pinkevitch REFERENCES ASTM D2171 REF 10T6052 REF 10T6053 Viscometer holder CMVV/AIVV Viscometer holder MKVV REFERENCES ASTM D2162 REF 10T6035 REF 10T6030 Viscometer holder Master Ubbelhode Viscometer holder Master Cannon Fenske Viscometer Holders 60

63 Accessories VISCOMETER WASHER Designed in order to eliminate hand cleaning of glass kinematic viscometer tubes. Main Characteristics Viscometer washer supplied with 6 nozzle stoppers. It allows external and internal washing of all types of viscometer tubes as mentioned in ASTM D446. Prewash viscometers with BIO2000E. Eliminate further hand cleaning with the use of T218TB. Viscometer tubes are suspended in BIOSANE solvent vapours at 80 C. Very Fast cleaning (5 to 15 min) for 6 viscometer tubes Negligibale solvent cunsumption REF Model ALV-110 (230V 50/60Hz) (115V -60Hz on request) REF T218TB Biosane T 218 solvent (per can of 26 ltrs) REF BIO2000E Biosane pre-wash For use on Width Depth Height Weight AC 230V, 50/60 Hz 5A 240 mm 260 mm 350 mm ± 7 kg ALV-110 Manuals see VISCOHANGER A seven position hanger for use with manual capillary glass viscometers. The unit facilitates safe, easy storage of viscometers once taken from a viscometer bath prior to cleaning. The detachable drip tray collects residual bath fluid and allows easy disposal to waste. Main Characteristics Made from stainless steel to aid chemical resistance Space saving footprint Dimensions 51 x 28 x 49 cm (LxWxH) Easy to clean Can be used with the Tamson viscometer holders REF 10T6065 Viscohanger Accessories Viscometer Hanger 61

64 Accessories 8 CHANNEL STOP-WATCH Timer to measure the time for a volume of liquid to flow under gravity through a calibrated glass capillary viscometer. The apparatus contains 8 individual stopwatches. Each stopwatch operates by pressing a single button to run, stop or reset. Auto power-off when no stopwatches are running. After power-off individual values are kept in memory. All values can be reset together or per channel. Main Characteristics 8 individual channels Easy to use Long battery life Uses simple 9V block (battery included) 0.01 sec resolution Outer dimension 195 x 112 x 46 mm (LxWxH) REF 10T Channel stop-watch ILLUMINATOR Backlight illuminator for viscosity baths. References REF 00T0909 Stand alone Z41 (85 230V/50~60Hz) Illuminator REF 00T0908 Backpanel with LED light for Tamson TV4000MKII (85 230V/50~60Hz) REF 00T0910 Z71 (230V/50Hz) Illuminator (Background light) for Tamson TV7000 REF 00T0915 Z71 (115V/60Hz) Illuminator (Background light) for Tamson TV7000 Available from our webshop Z41 & Z71 Timer Backlight 62

65 Accessories GENERAL PURPOSE VISCOSITY REFERENCE STANDARD ISO and ISO Guide 34 certified viscosity standards are for the calibration and verification of glass capillary viscometers and other viscosity measuring equipment where operating temperature is controlled precisely. Main Characteristics UKAS certified to ISO Quality System. Manufactured in accordance with ASTM D Density g/ml in accordance with ASTM D Kinematic (cst) & dynamic viscosity (mpa.s) given at all temperatures. Standard pack size 500 ml. Fully traceable to National Standards. Ensures full compliance to ASTM & IP test method protocol. Tamper evident security packaging. 2 year shelf life. Reference standard REFERENCE number Viscosity standard VISCOSITY STANDARDS (Flask of 500 ml) - with UKAS certificate Approximate Kinematic Viscosity in mm 2 /s (Centistokes) 20 C 25 C 40 C 50 C 60 C 80 C 100 C 25T0726* N T0727* N T0728* N T0729 N T0700 S T0701 S T0730 N T0702 S T0731 N T0703 S T0732 N T0741 N T0704 S T0742 N T0733 N T0740 N T0705 S T0743 N T0734 N T0744 N T0706 S T0735 N T0707 S T0737 N T0722 S T0746 S T0745 N Nominal Values (mpa s) * Hazardous to ship FOR ALL OTHER VISCOSITY STANDARDS, TBN/TAN STANDARDS, CERTIFIED REFERENCE MATERIALS AND OTHER REFERENCE STANDARDS, PLEASE VISIT OUR WEBSITE Reference Oils 63

66 Accessories 4.3 ASTM Thermometers Precision liquid glass thermometers for use in specific ASTM / IP test methods. These thermometers are of the highest quality and easily readable with an etched surface scale and yellow backing. The ASTM designation ensures that these thermometers meet the strict guidelines of the American Society for Testing and Materials (ASTM). Thermometers come with certificate of conformity. Other certificates on request. ASTM No. REF Cat. Range Subd ivisio n in C Immersion In mm 1 C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à Total 8 C 25T à Total 9 C 25T à C 25T à C 25T à C 25T à Total 13 C 25T à Total 14 C 25T à C 25T à Total 16 C 25T à Total 17 C 25T à Total 18 C 25T à Total 19 C 25T à Total 20 C 25T à Total 21 C 25T à Total 22 C 25T à Total 23 C 25T à C 25T à C 25T à C 25T à Total 33 C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à Total 45 C 25T à Total 46 C 25T à Total 47 C 25T à Total 49 C 25T à C 25T à Total 54 C 25T à Total 56 C 25T à Total 57 C 25T à C 25T à C 25T à Total ASTM No. REF Cat. Range Subdiv ision in C Immersion In mm 63 C 25T à Total 64 C 25T à Total 65 C 25T à Total 67C 25T à Total 68 C 25T à Total 71 C 25T à C 25T à Total 82 C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à Total 99 C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à C 25T à Total 111 C 25T à C 25T à Total 113 C 25T à Total 114 C 25T à Total 116 C 25T à Total 117 C 25T à Total 118 C 25T à Total 119 C 25T à C 25T à Total 121 C 25T à Total 122 C 25T à Total 126 C 25T à Total 127 C 25T à Total 128 C 25T à Total REF 00T0239 Thermometer holder For our digital thermometer, conform ASTM D445-11A, please see our special section Calibration/ TT-3 Thermometers 64

67 Accessories 4.4 Tubing to be used with circulators To replace unsafe tubing to circulate fluids at high or low temperatures. Main Characterics Temperature range ambient C/+482 C. Complete stainless steel 316 quality. Flexible. Chemical resistant. Standard threads (1/4 and 3/8 straight internal, flat seal) Flex hose insulated+ non insulated Corrugated (NON braided) REF Length [mtr]* Fitting [inch]** Pressure [bar] Bending (inner) radius Description 12T ¼ 10 16[mm] Not insulated 12T ¼ 10 16[mm] Not insulated 12T /8 5,5 22[mm] Not insulated 12T /8 5,5 22[mm] Not insulated 12T ¼ 10 40[mm] Insulated*** 12T ¼ 10 40[mm] Insulated*** 12T /8 5,5 50[mm] Insulated*** 12T /8 5,5 50[mm] Insulated*** * Other lengths on request. ** Both sides, internal straight, flat seal. OPTIONS Description (all stainless steel) Dimensions REF 23T0078 Male male nipple g1/4o x g1/4o 23T0077 Male male nipple g3/8o x g3/8o 23T0075 T-connector 3x g1/4i 23T0079 Male male nipple R1/4o x R1/4o 23T0080 Male male nipple R3/8o x R3/8o 23T0071 T-connector 3x g3/8i 23T0023 T-valve 3x g3/8i 23T0073 Female female socket g1/4ix g1/4i 23T0081 Female female socket g3/8ix g3/8i 23T0082 Reducing bush g1/4ix g3/8o 23T0084 Washer fiber for g1/4 (diameter hole=1/4 ) 23T0085 Washer fiber for g3/8 (diameter hole=3/8 ) 23T0086 Washer fiber outer dimension 1/4" 23T0087 Washer fiber outer dimension 3/8" Foam insulation, adhesive tape on request I = Inner thread. o = Outer thread. g = British Standard Pipe straight (not conical). R = BSP conical. Detailed information at Tubing 65

68 Accessories 4.5 Manifold To connect two or more devices to one cold flow of a Tamson circulator. Main Characterics The manifold unit can be mounted on the wall and uses manual valves connecting the analysers to the circulating cold flow. The manifold can be used to connect 2 devices to a single low temperature circulator. The manifold can be set in series offering 4 devices to be connected to one cooling circulator. Its small dimensions, 270 x 126 mm (WxH), makes it easy to mount and install. The manifold is well insulated. Tamson also provides low temperature insulated hoses to safely and easy connect the cold property apparatus. These hoses consist of a flexible stainless steel inner hose and are insulated with black armaflex covered with a protecting nylon sleeve. All connections are standard 3/8" BSP. For interconnection to other threads, stainless steel adaptor pieces are available. Manifold Side view Manifold 66

69 Accessories 4.6 Bath fluids To replace water as a bath fluid. Viscosity, volatility and other properties that change with temperature affect the performance of fluids in controlled baths and circulators. Tamson has tested and used each of the fluids we sell, over the ranges recommended in the following table, each fluid remains at a low enough viscosity to be adequately pumped or stirred. Whether your application is industrial or critical lab calibration work, Tamson fluids give you top performance and stability. Oil Main Characteristics Type Remarks Mineral T150 Yellow Mineral oil Silicon Transparent Dimethyl siloxane polymer Silicon Transparent Dimethyl siloxane polymer Silicon Silicon 210 Dark Dimethyl poly siloxane Silicon Silicon 550 Colourless Polyphenyl methyl dimethyl siloxane Life Viscosity [cst] X Temp. Package 150 C 200 C 250 C 80 C 100 C C Range C 1/2 yr X X C 20 ltrs No limit No limit No limit No limit 200hrs <10hrs C 20 ltrs 200hrs <10hrs C 20 ltrs <2yrs <1yr (35) C 20 ltrs <1yr <1200 hrs (50) C 20 ltrs REF 00T0220 Tamson mineral oil T150 20ltrs REF 08T0001 Silicon cSt 20ltrs Transparent REF 00T0226 Silicon cSt -20ltrs Transparent REF 00T0229 Silicon cSt - 20ltrs Transparent REF 00T0231 Silicon ltrs Darkish REF 00T0238 Silicon ltrs Transparent ( C/ F) ( C/ F) ( C/ F) ( C/ F) ( C/ F) ( C/ F) Bath Oils 67

70 Calibration baths & Thermometers 68

71 5 Calibration Baths & Thermometers 5.1 Calibration Baths Calibration of temperature measuring instruments with thermostats. The most important prerequisite for calibration is very high temperature stability. Thermostats with bath liquids are the most precise devices for this application as they allow especially good temperature stability and homogeneity. Liquid bath thermostats are superior to incubators and metal block thermostats, since liquids transfer heat between 40 and 60 times better than air. As the world s leading provider of precise thermostats, we offer a line of calibration thermostats with various performance levels. Depending on your specified bath size, temperature range, temperature stability, and other technical features, you are sure to find the ideal device for your application. TV12 Calibration Calibration Baths TV12 TV12LT TV4000DC TV15000 TV16000 Temperature Range ambient..120 C ambient..302 F (1) C F (2) C F ambient..230 C ambient..446 F C F C Temperature Stability Stdev ±0.002 C Stdev C ±0.002 C@40 C ± C ± C Setting ± 0.01 C ± 0.01 C ± 0.01 C ± C ± C Bath volume L 15 L 40 L 155 L 160 L Bath opening 248*73 mm 248*73 mm 260*240 mm 230*820mm 250*365 mm REF 230V/50Hz 00T0400 (1) 00T T T T0490 (2) 00T0425 REF 230V/60Hz 00T0400 (1) 00T T T T0495 (2) 00T0435 REF 115V/60Hz 00T0405 (1) 00T0415 (2) 00T T T T0492 We offer many other calibration baths. To offer you the right bath for your calibrations, please contact Tamson. For the TV12, see 1.3 For the TV12LT, see 1.6 For the TV4000DC, see 1.2 For the TV15000, see 1.10 For the TV16000, see 1.9 More product information at Calibration Baths 69

72 Calibration Bath & Thermometers 5.2 Thermometers Digital Thermometer THIS UNIT CONFORMS TO REQUIREMENTS OF ASTM D445 To calibrate probes, thermometers, instruments, indicators, and temperature measurement of viscosity baths. Main Characteristics The Tamson Thermometer has a three decimal reading. The thermometer uses a standard PT100 probe for measurements from C or F. The thermometer uses an internal correction table to meet the IEC751 required accuracy of ±0.01 C. A high accuracy data converter samples the PT100 value and a microprocessor is used to correct these values. The calibration data is kept in internal memory. A second memory offers the possibility for data logging. Sampling times can vary from 1 second to 300 seconds. At each interval the temperature is measured and stored. Each measurement has an individual time stamp and can be recalled easily using the PC software. The thermometer operates on a Battery pack. A full charge supplies power for 16 days of continuous use. When off the battery will keep its charge. Digital Thermometer 3 decimals TT3 Item Unit TT3 Range C / F Reading C or F menu selectable Interface RS232 Resolution [ C/ F] Accuracy [ K] ± 0.01 Linearity [ K] ± 0.01 Power Battery NiMH operated Charge 2 Hrs Mains adapter ~50/60Hz 9V-1A Sleep current 0.01 ma Nominal current 2 ma Battery pack 800 mah Log time [hr] 19 hr sample rate 1s 5700 hr sample rate 300s Sample rate [sec] 1,2,5,10,20,60,120,300 Dimensions [LxWxH] 105x32x150, excl probe Weight [gr] 355 (inclusive probe) Power [Watt] Battery NiMH operated Frequency [Hz] Suited for both 50 & 60 CE All models conform to CE regulation REF 10T6095 TT3 Digital Thermometer Digital Thermometer 70

73 Calibration baths & Thermometers Ne ce ssary Accessories TT-3 REF 25T2350 Temperature probe C/ F 115x3mm, Class a REF 21T0200 Blue suitcase to store TT3 Options TT-3 REF 10T6096 Works certificate C REF 10T6097 Works certificate C REF 10T6098 Verification calibration per point [ C] REF 24T0038 RS232.. USB converter REF 24T0037 Flatcable 2 mtr REF 24T0036 Flatcable 1 mtr Manuals online at Digital Thermometer 71

74 Calibration baths & Thermometers 5.3 Tamson Controller Unit The Tamson Controller Unit (TCU-70) is based on the Tamson microprocessor controller, which is used in our product range. This stand alone unit can be used to control individual systems where extreme accuracy is required. The system offers two types of heating elements; High voltage mains (AC) via solid state and Stabilized DC control via a separate power supply. The unit uses PID control and a PT100 probe. Best achieved accuracy is ±0.002 C over 1 hour. The bath temperature can be set from -100 C to a maximum of +250 C (482 F) in steps of degree. The display also has an offset witch can be set in steps of 0.01 C. The unit conforms to CE regulation. It further is equipped with multiple safety features in order to guarantee safe around the clock operation. Tamson Controller Unit Range C / F Reading C or F Setting ± Linearity ± 1 C Stability ± K (± typical) Stabilization 15 min Heating control Solid state 1500 W Heating boost Solid state 1500 W Heating analog Output control 3 x 1000 W 48 V-DC Pump 3 amps max Sensor PT100 Communication RS232 Dimensions (LxWxH) 230 x 210 x 120 mm Weight 4 kg REF 00T0264 Tamson Controller Unit C control Tamson Catalogue Controller Unit 72

75 Content All popular viscometers: - D446 IP 71-4 Accessories...53 BS188 ISO Viscometers Viscosity Accessories ASTM Thermometers Calibrated 4.4 Tubing to be used with circulators Manifold Bath fluids (UKAS) 5 Calibration Baths & Thermometers...69 viscometers 5.1 Calibration Baths Thermometers Digital Thermometer Tamson Controller Unit Viscometer tube Zeitfuchs Cross-arm viscometer See page 53

76 Powered by Dutch Technology Since 1878 Manufacturer and supplier of: Viscosity measurement equipment Calibration baths Heating baths and circulators Cooling baths and circulators Reference standards Digital contact thermometers (DCT) ASTM/IP equipment: D130 D445 & D446 D1265 D1298 D1796 & D4007 D1838 D2068 D2162 D2171 E20-09 IP227 bv Tel +31 (0) The Netherlands

Manual Kinematic Viscosity Bath Tamson TV12

Manual Kinematic Viscosity Bath Tamson TV12 Manual Kinematic Viscosity Bath Tamson Rev 1.05 1 Viscosity Business Today Testing kerosene Testing diesel Testing lubricants Testing fuel oils Testing residues Testing bituminous or asphalt samples Testing

More information

Manual Kinematic Viscosity Bath Tamson TV2000 & TV4000 ASTM D445, IP71, ISO 3104

Manual Kinematic Viscosity Bath Tamson TV2000 & TV4000 ASTM D445, IP71, ISO 3104 Manual Kinematic Viscosity Bath Tamson ASTM D445, IP71, ISO 3104 Rev 1.04 Viscosity Business Today Testing kerosene Testing diesel Testing lubricants Testing fuel oils Testing residues Testing bituminous

More information

Foaming of Lubricating Oils (manual)

Foaming of Lubricating Oils (manual) Foaming of Lubricating Oils (manual) ASTM D 892, ASTM D 6082 sequence IV, ISO 6247, DIN 51566, IP 146, JIS K2518, BS 5092 (obs.) Product group(s): User group(s): Scope: Lubricant Testing Automotive, Engine

More information

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Instruments for the Analysis of Petroleum Products. Oxidation Stability Instruments for the Analysis of Petroleum Products Oxidation Stability What is Oxidation Stability? Oxidation stability describes the resistance of a material towards oxygen. This is a basic requirement

More information

For the fastest possible service, you can now reach Koehler via the Internet. On our website, you can:

For the fastest possible service, you can now reach Koehler via the Internet. On our website, you can: For the fastest possible service, you can now reach Koehler via the Internet. On our website, you can: Locate the test instrument you need based on your desired ASTM method. Download product information.

More information

Petroleum Testing Equipment

Petroleum Testing Equipment Petroleum Testing Equipment www.koehlerinstrument.com BOHEMIA, NEW YORK HOUSTON, TEXAS Worldwide Support Providing quality testing instrumentation and technical support services for research and testing

More information

A SURVEY OF OUR KNOW-HOW : PETROLEUM GLASSWARE VISCOMETER TUBES

A SURVEY OF OUR KNOW-HOW : PETROLEUM GLASSWARE VISCOMETER TUBES N O R M A L A B A N A L I S A SURVEY OF OUR KNOW-HOW : PETROLEUM GLASSWARE VISCOMETER TUBES NORMALAB ANALIS FRANCE S.A. 14, rue des Lilas 76210 LINTOT - FRANCE Tel : (33) 02 35 38 59 59 Fax : (33) 02 35

More information

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample Suitable for measuring gas oils, distillate fuels and diesel fuels, as specified in ASTM D975, EN590 and ISO 8217 (marine fuels). The RHEOTEK AKV-diesel is a fully automated viscometer system suitable

More information

Penetration. Test Methods

Penetration.   Test Methods Test Methods Penetration of Bituminous Materials ASTM D5; IP 49; DIN 52010 Cone Penetration of Lubricating Grease ASTM D217; IP 50; ISO 2137; DIN 51804; FTM 791-311, FTM 791-313 Cone Penetration of Petrolatum

More information

PETRODIST PILODIST. Crude oil distillation systems according to ASTM - standards for fractionation and boiling analysis

PETRODIST PILODIST. Crude oil distillation systems according to ASTM - standards for fractionation and boiling analysis With kind permission of BP Gelsenkirchen GmbH PETRODIST Crude oil distillation systems according to ASTM - standards for fractionation and boiling analysis Version 9/ January 2012 1 PETRODIST is a brand

More information

Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. Bioengineering RALF Basic + Advanced

Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. Bioengineering RALF Basic + Advanced 1 Data Sheet Bioengineering RALF Bioengineering RALF Autoclavable Laboratory Bioreactors / Fermentors with glass vessels. The glass vessels have both a round bottom and stainless steel lid. The system

More information

U tube viscometer. Kinematic viscosity bath RASAYAN

U tube viscometer. Kinematic viscosity bath RASAYAN Viscosity The viscosity of a fluid is a measure of its resistance to gradual deformation by shear stress or tensile stress. For liquids, it corresponds to the informal notion of "thickness". For example,

More information

Integrated temperature test and calibration bench Model CBS-SC4000

Integrated temperature test and calibration bench Model CBS-SC4000 Calibration technology Integrated temperature test and calibration bench Model CBS-SC4000 WIKA data sheet CT 92.33 Applications Testing and calibration of temperature measuring instruments such as: - Mercury

More information

Cassia Siamia BLOOD BANK REFRIGERATED CENTRIFUGE MP 6000 R. Technical Data (MP 6000 R)

Cassia Siamia BLOOD BANK REFRIGERATED CENTRIFUGE MP 6000 R. Technical Data (MP 6000 R) BLOOD BANK REFRIGERATED CENTRIFUGE The range of Blood component separation equipment and Hi-Volume Centrifuges are designed for Blood bags, large capacity centrifuge tubes and bottles. These centrifuges

More information

GLASSCO LABORATORY EQUIPMENTS PVT. LTD.

GLASSCO LABORATORY EQUIPMENTS PVT. LTD. PROGRAMMED FOR PRECISIO N GLASSCO LABORATORY EQUIPMENTS PVT. LTD. STAINLESS STEEL TOP Magnetic Stirrer with Hotplate - Analog Aluminium Moulded Construction Easy temperature & Stir controls Installed with

More information

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications Water Baths & Shaking Water Baths Quality Technology for Routine Applications 94 Water Baths and Shaking Water Baths The TW and SW Water Bath Series are microprocessor-controlled, durable, and long-lasting

More information

VISCOSITY CALIBRATION STANDARDS

VISCOSITY CALIBRATION STANDARDS VISCOSITY CALIBRATION STANDARDS Cold-Cranking Simulator Standards (CCS) ASTM D 9 ISO 170 certified CCS viscosity standards are for the calibration and verification of analytical equipment used in Cold

More information

Let us be your partners in the viscosity measurement

Let us be your partners in the viscosity measurement Kinematic Viscosity To all our clients, Let us be your partners in the viscosity measurement Today s business world requests new challenges and further reaction to the market requirements. Fungilab s aim,

More information

ROTIXA 50 S/50 RS Floorstanding Centrifuges classic/cooled

ROTIXA 50 S/50 RS Floorstanding Centrifuges classic/cooled ROTIXA 50 S/50 RS Floorstanding Centrifuges classic/cooled RoTIXA 50 S/50 RS Among experts ROTIXA has become a household word for high sample throughput. This is why ROTIXA models are the centrifuges of

More information

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability PMA 5 Pensky-Martens Flash Point Tester ::: Volatility... Flammability A Tradition of Competence 140 years of developing, producing and supporting excellent flammability instruments. 140 years of technology

More information

Paragon Scientific Ltd Proficiency Testing Scheme Schedule

Paragon Scientific Ltd Proficiency Testing Scheme Schedule Paragon Scientific Ltd Proficiency Testing Scheme Schedule Proficiency Testing Scheme Schedule Page 1 of 16 Issue : 29/01/2015 Print : 25/06/2018 Viscosity ASTM D445 - Standard Test Method for Kinematic

More information

SCOPE OF ACCREDITATION

SCOPE OF ACCREDITATION Standards Council of Canada 600-55 Metcalfe Street Ottawa, ON K1P 6L5 Canada Conseil canadien des normes 55, rue Metcalfe, bureau 600 Ottawa, ON K1P 6L5 Canada SCOPE OF ACCREDITATION InnoTech Alberta Inc.

More information

Procedure for Koehler Digital Constant Temperature Viscosity Bath

Procedure for Koehler Digital Constant Temperature Viscosity Bath Procedure for Koehler Digital Constant Temperature Viscosity Bath Intro: This unit is designed to perform kinematic viscosity tests using glass capillary viscometers, for this lab you will be using Cannon-Fenske

More information

Instruments for Chemical and Petroleum Products. Flash Point

Instruments for Chemical and Petroleum Products. Flash Point Instruments for Chemical and Petroleum Products Flash Point A Tradition of Competence 140 years of technological advances lie between the first flash point tester and today s Anton Paar product line of

More information

ADU 5. Automatic Distillation Unit

ADU 5. Automatic Distillation Unit ADU 5 Automatic Distillation Unit Atmospheric Distillation Distillation tests are used to characterize the volatility of petrochemical products. These volatility characteristics are a critical measurement

More information

ROTOFIX 46/46 H Benchtop centrifuges classic/heated

ROTOFIX 46/46 H Benchtop centrifuges classic/heated ROTOFIX 46/46 H Benchtop centrifuges classic/heated ROTOFIX 46/46 H DESIGN Special applications require special solutions Ideal centrifuges for research and industrial laboratories offer a wide range of

More information

LABORATORY Viscometers

LABORATORY Viscometers LABORATORY Viscometers www.irmeco.de Cannon-Fenske Routine Cannon-Fenske Routine Viscometer according to ASTM D445-446, ASTM D2515, ISO 3104-3105 used for quick and easy measurement of the viscosities

More information

Softening point by Ring & Ball. Density and relative density of liquids by Hubbart pycnometer

Softening point by Ring & Ball. Density and relative density of liquids by Hubbart pycnometer Softening point by Ring & Ball Density and relative density of liquids by Hubbart pycnometer Distillation of petroleum Melting point of petroleum wax Precipitation number of lubricating oils Saponification

More information

Flash Point Process Analyzer

Flash Point Process Analyzer Norms and standards ASTM D 56 ASTM D 93; DIN EN ISO 2719; IP 34 DIN EN ISO 13736; IP170 DIN 51755 Application The BARTEC BENKE Flash Point Process Analyzer (FPA-4) is a continuously measuring analyzer,

More information

Refrigerated incubator with Peltier technology

Refrigerated incubator with Peltier technology KT series 53 Incubators and cooling incubators Refrigerated incubator with Peltier technology The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness.

More information

Product Profile. Laboratory instruments. for quality control, analysis and calibration. Fuels

Product Profile. Laboratory instruments. for quality control, analysis and calibration. Fuels Fuels Product Profile Biofuels Petroleum feedstock Crude oil Chemicals Lubricants Cosmetics Paints and varnishes Bitumens Recycled product Laboratory instruments for quality control, analysis and calibration

More information

Heating oven with mechanical control

Heating oven with mechanical control ED series 23 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C. Thanks to the

More information

Interface I-300 / I-300 Pro Technical data sheet

Interface I-300 / I-300 Pro Technical data sheet Interface I-300 / I-300 Pro Technical data sheet The Interface I-300 or I-300 Pro are the central control unit for all process parameters of a Rotavapor R-300 system: rotation speed, temperature (heating

More information

Circulating Chillers / Immersion Coolers

Circulating Chillers / Immersion Coolers Circulating / Immersion Coolers Many applications depend on a reliable source of cooling. Circulating chillers in the Unichiller range offer an ideal solution for environmentally friendly and economical

More information

IKA Mixing Magnetic stirrers with heating

IKA Mixing Magnetic stirrers with heating with heating RET basic safety control RET basic C safety control RET basic safety control IKAMAG, RET basic C safety control IKAMAG with new heating and stirring technology for fast, accurate temperature

More information

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles P.

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles P. ACE For Glass Vessels Borosilicate Glass Fused-to-Glass Conductive Heating Film Integral Outer Insulation Instatherm The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and

More information

ROTO SILENTA 630 RS Floorstanding Centrifuge cooled

ROTO SILENTA 630 RS Floorstanding Centrifuge cooled ROTO SILENTA 630 RS Floorstanding Centrifuge cooled ROTO SILENTA 630 RS The ROTO SILENTA 630 RS offers outstanding performance in fast, efficient centrifuging of blood bags and large sample volumes. It

More information

air-cooled 18,000 rpm 25,356 xg 24,000 rpm 45,078 xg refrigerated Table-Top High-Speed Centrifuges High performance instrument for the daily routine

air-cooled 18,000 rpm 25,356 xg 24,000 rpm 45,078 xg refrigerated Table-Top High-Speed Centrifuges High performance instrument for the daily routine air-cooled 18,000 rpm 25,356 xg 24,000 rpm 45,078 xg refrigerated Table-Top High-Speed Centrifuges High performance instrument for the daily routine Universal Centrifuges High-Speed Centrifuges with Flexible

More information

ISBN SANS 342:2006 Edition 4 SOUTH AFRICAN NATIONAL STANDARD Automotive diesel fuel Published by Standards South Africa 1 dr lategan roa

ISBN SANS 342:2006 Edition 4 SOUTH AFRICAN NATIONAL STANDARD Automotive diesel fuel Published by Standards South Africa 1 dr lategan roa ISBN 0-626-18752-4 SOUTH AFRICAN NATIONAL STANDARD Automotive diesel fuel Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001 tel: 012 428 7911 fax: 012 344

More information

Viscosity & Flash Point Standards For Reference, Validation, and Calibration

Viscosity & Flash Point Standards For Reference, Validation, and Calibration & Flash Point s For Reference, Validation, and Calibration Since 1938 CANNON Instrument Company has been a leader in viscosity measurement. We provide a broad range of viscosity standards and flash point

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LABORATORY SERVICES, PETROTRIN Southern Main Road Pointe-A-Pierre, Trinidad, Trinidad & Tobago Peter Bhim Phone: 868 658 4200 CHEMICAL Valid To: November 30,

More information

Incubators. Incubators

Incubators. Incubators Incubators Stuart has a number of incubators specially designed for accurate and reproducible temperature controlled applications. All incubators have state of the art microprocessor detection, setting

More information

ROTOFIX 46/46 H Benchtop centrifuges classic/heated

ROTOFIX 46/46 H Benchtop centrifuges classic/heated ROTOFIX 46/46 H Benchtop centrifuges classic/heated ROTOFIX 46/46 H Special applications require special solutions Centrifuges for use in research and industrial laboratories should ideally be robust and

More information

RSSOT New Standards ASTM D 7525 ASTM D 7545 ASTM D 7525 ASTM D Manufacturer since

RSSOT New Standards ASTM D 7525 ASTM D 7545 ASTM D 7525 ASTM D Manufacturer since RSSOT New Standards ASTM D 7525 ASTM D 7545 EN RSSOT 16091 ASTM D 7525 ASTM D 7545 Manufacturer since 1873 WWW.PETROTEST.COM Oxidation Stability Rapid Small Scale Oxidation Test (RSSOT) A new Method for

More information

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles.

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles. ACE For Glass Vessels Borosilicate Glass Fused-to-Glass Conductive Heating Film Integral Outer Insulation Instatherm The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and

More information

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels ASTM D 6751 02 Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels Summary This module describes the key elements in ASTM Specifications and Standard Test Methods ASTM Specification

More information

Heating oven with natural convection

Heating oven with natural convection ED series 23 Drying ovens / Heating ovens Heating oven with natural convection The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C. Thanks to the

More information

www.labtron.com info@labtron.com Distillation Tester LDT-A10 Labtron LDT-A10 is automated and can withstand a very high temperature. It is designed according to Test Methods for Distillation Characteristics

More information

Extremely quiet due to unique flexible drive system. Super High-Speed Centrifuge. Refrigerated - 30,000 rpm / 70,434 xg

Extremely quiet due to unique flexible drive system. Super High-Speed Centrifuge. Refrigerated - 30,000 rpm / 70,434 xg Extremely quiet due to unique flexible drive system Super High-Speed Centrifuge Refrigerated - 30,000 rpm / 70,434 xg Super High-Speed High-Speed Centrifuge with Flexible Axis! This provides the best smooth

More information

PrO-ASTM Centrifuges. Centurion. C1015 Micro Prime Centrifuge. A Micro that offers: Oil testing. Petroleum testing, ASTM methods

PrO-ASTM Centrifuges. Centurion. C1015 Micro Prime Centrifuge. A Micro that offers: Oil testing. Petroleum testing, ASTM methods PrO-ASTM Centrifuges Oil testing. Petroleum testing, ASTM methods C1015 Micro Prime Centrifuge C1015. (230V 50/60Hz). 1.C1015. (110V 60Hz) Speed Rcf Max Timer Dims HWD Weight Power Memory Accel rates Decel

More information

Date and Time of Pre Bid Meeting November 22, 2016 at a.m

Date and Time of Pre Bid Meeting November 22, 2016 at a.m Addendum No. 0 TENDER FOR SUPPLY, DELIVERY, INSTALLATION AND COMMISSIONING OF EQUIPMENT FOR LATEX TECHNOLOGY LABORATORY OF FACULTY OF ANIMAL SCIENCE AND EXPORT AGRICULTURE Tender No - UWU/B/C/6/09 Date

More information

User Manual Temperature Calibrator JOFRA ATC-125/140/156/157/250/320/650 A/B Copyright 2005 AMETEK DENMARK A/S ( UK)

User Manual Temperature Calibrator JOFRA ATC-125/140/156/157/250/320/650 A/B Copyright 2005 AMETEK DENMARK A/S ( UK) User Manual Temperature Calibrator JOFRA ATC-125/140/156/157/250/320/650 A/B Copyright 2005 AMETEK DENMARK A/S (105447-UK) 13-03-2007 Fig 1a (calibrator view) 6 Reference sensor (if available) 5 CA LI

More information

UNIVERSAL 320/320 R Benchtop Centrifuges classic/cooled

UNIVERSAL 320/320 R Benchtop Centrifuges classic/cooled UNIVERSAL 320/320 R Benchtop Centrifuges classic/cooled UNIVERSAL 320/320 R PERFORMANCE There are good reasons why we have called these centrifuges UNIVERSAL. Their excellent performance and comprehensive

More information

ROTOFIX 46/46 H Benchtop centrifuges classic/heated

ROTOFIX 46/46 H Benchtop centrifuges classic/heated ROTOFIX 46/46 H Benchtop centrifuges classic/heated ROTOFIX 46/46 H DESIGN Special applications require special solutions Ideal centrifuges for research and industrial laboratories offer a wide range of

More information

Immunity: EN capacity 75 µl Capillaries. 1,5 x 75 mm. Rotor and Lid as evaluation disc incl.

Immunity: EN capacity 75 µl Capillaries. 1,5 x 75 mm. Rotor and Lid as evaluation disc incl. CENTRIFUGES BOECO HEMATOCRIT CENTRIFUGE H-240 High-speed bench-top centrifuge for microhematocrit determinations with brushless frequency drive. At 16.060 g sedimentation is completed in just a little

More information

Temperature multi-function calibrator Model CTM

Temperature multi-function calibrator Model CTM Calibration Temperature multi-function calibrator Model CTM9100-150 WIKA data sheet CT 41.40 for further approvals see page 3 Applications Testing and calibration of all types of temperature measuring

More information

Heating chamber with mechanical convection

Heating chamber with mechanical convection FED series 240 Drying ovens / Heating ovens Heating chamber with mechanical convection The multi-talented BINDER heating chamber of the FED series provides almost unlimited capacity and is particularly

More information

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion

Standard Test Method for Sulfur in the Analysis Sample of Coal and Coke Using High-Temperature Tube Furnace Combustion IAS Accreditation Number Company Name Address Contact Name Telephone +966-14-398-2118 Effective Date of Scope May 1, 2018 Accreditation Standard ISO/IEC 17025:2017 TL-743 Yanbu Industrial Area Yanbu, Madina

More information

Heating chamber with mechanical convection

Heating chamber with mechanical convection FED series 720 Drying ovens / Heating ovens Heating chamber with mechanical convection The multi-talented BINDER heating chamber of the FED series provides almost unlimited capacity and is particularly

More information

Climate chamber with illumination

Climate chamber with illumination KBW series (E5.1) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural

More information

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology zfa01 Global Filtration Technology 157 Why on-site fluid analysis? Certification of fluid cleanliness levels Immediate and accurate results Early warning tool to help prevent catastrophic failures in critical

More information

ROTO SILENTA 630 RS Floorstanding Centrifuge cooled

ROTO SILENTA 630 RS Floorstanding Centrifuge cooled ROTO SILENTA 630 RS Floorstanding Centrifuge cooled ROTO SILENTA 630 RS The ROTO SILENTA 630 RS offers outstanding performance in fast, efficient centrifuging of blood bags and large sample volumes. It

More information

PETROLEUM TESTING EQUIPMENT N-WISSEN 2016

PETROLEUM TESTING EQUIPMENT N-WISSEN 2016 ` PETROLEUM TESTING EQUIPMENT N-WISSEN 2016 N-Wissen products range includes the following petroleum testing and measuring equipment: ASTM D 5 - D 217 Digital penetrometer for bitumens; ASTM D 5 - D 217

More information

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001)

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001) RULE 346. LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001) A. Applicability The provisions of this rule shall apply to the transfer of organic liquids into an organic liquid

More information

LUBRICATING GREASES. Test Methods

LUBRICATING GREASES.  Test Methods LUBRICATING GREASES s Page Evaporation Loss of Lubricating Greases and Oils ASTM D972, D2878; IP 183; FTM 791-351...148 Evaporation Loss of Lubricating Grease Over Wide Temperature Range ASTM D2595, D2878...149

More information

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5 T2FM Q500 Spectroil M Q200 MiniLab 53 MiniLab 153 MicroLab 30-40 0 Q6000 Aquamax FlashPoint Q300/310 Q3000 Pat 940 Density 5 BENEFITS LNF Q200 Series Particle Counter, Wear Particle Classifier, Ferrous

More information

Heating chamber with mechanical convection

Heating chamber with mechanical convection FED series 53 Drying ovens / Heating ovens Heating chamber with mechanical convection The multi-talented BINDER heating chamber of the FED series provides almost unlimited capacity and is particularly

More information

Climate chambers with illumination

Climate chambers with illumination KBW series (E5.1) Climate chambers with illumination Climate chambers with illumination The BINDER KBW series climate chamber with illumination achieves homogeneous light distribution and ensures consistent

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

Heating chamber with mechanical convection

Heating chamber with mechanical convection FED series 53 Drying ovens / Heating ovens Heating chamber with mechanical convection The multi-talented BINDER heating chamber of the FED series provides almost unlimited capacity and is particularly

More information

Safety drying ovens with expanded temperature range

Safety drying ovens with expanded temperature range MDL series 115 Safety drying ovens Safety drying ovens with expanded temperature range The BINDER MDL, with enhanced control function, works at temperatures up to 350 C (662 F). It is it perfectly suited

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

Heating oven with mechanical convection

Heating oven with mechanical convection FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous

More information

Precision Thermometers for Material Testing

Precision Thermometers for Material Testing Precision Thermometers for Material Testing Precision thermometers acc. to ASTM, IP, BS, DIN, ISO, ANSI, AFNOR, S.T.P.T.C. For standardized material testing procedures such as mineral oil testing Catalogue

More information

Micro Motion 7827 Digital Viscosity Meter

Micro Motion 7827 Digital Viscosity Meter Product Data Sheet PS-001217, Rev. C April 2013 Micro Motion 7827 Digital Viscosity Meter Micro Motion viscosity meters are built to tackle the most demanding process and control applications. Rugged and

More information

Closed Cup Flash Point Tester

Closed Cup Flash Point Tester www.labtron.com info@labtron.com We have distinguished ranges of Closed Cup Flash Point Tester especially designed to offer highest level of accuracy and quality giving a versatility in the capacity and

More information

The Safest Heating Method!

The Safest Heating Method! ACE Instatherm For Glass Vessels The Safest Heating Method! Borosilicate Glass Eliminate the need for heating tapes, immersion heaters and heating mantles. Instatherm is a safer, more precise heating method

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK SGS West Thurrock Laboratory Contact: David Mercer (Laboratory Manager) 859 London Road Tel: +44 (0)1708 681943 West Thurrock Fax: +44 (0)1708

More information

2 ADAPTERS. Bushing / Connecting. Glass Bushing Adapters. Straight Connecting Adapters. PTFE Bushing Adapters. Offset Connecting Adapters

2 ADAPTERS. Bushing / Connecting. Glass Bushing Adapters. Straight Connecting Adapters. PTFE Bushing Adapters. Offset Connecting Adapters ADAPTERS Whether converting joint types, reducing or enlarging joints, or creating connections in a distillation apparatus, Kimble offers a comprehensive selection of adapters including bushing adapters,

More information

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection Model ED 400 Drying and heating chambers Classic.Line with natural convection The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 C. Thanks to the

More information

Draft Indian Standard SYN GAS/ AMMONIA TURBO COMPRESSOR LUBRICATING OILS SPECIFICATION

Draft Indian Standard SYN GAS/ AMMONIA TURBO COMPRESSOR LUBRICATING OILS SPECIFICATION Comments Only BUREAU OF INDIAN STANDARDS Draft Indian Standard Doc:PCD 3(2537)C September 2012 SYN GAS/ AMMONIA TURBO COMPRESSOR LUBRICATING OILS SPECIFICATION Not to be reproduced without the permission

More information

LAUDA Integral. Process thermostats for professional external thermostating across a wide temperature range from -90 up to 320 C

LAUDA Integral. Process thermostats for professional external thermostating across a wide temperature range from -90 up to 320 C LAUDA Integral Process thermostats for professional external thermostating across a wide temperature range from -9 up to C Application examples Process technology Process engineering Production Research

More information

Environmental/Analytical LabCivil Engineering Lab Equipment

Environmental/Analytical LabCivil Engineering Lab Equipment DIGITAL PH METER Display : 3.5 Digit LED. Range : ph 0 to 14.00, mv 0 to ± 1999. Resolution : ph 0.01, mv 1. : ph ± 0.01, mv ± 1 mv. Temp. Compensation : Auto 0 to 100 deg. C., Manual 0 to 100 deg. C.

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 0-626-18752-4 SANS 342:2006 SOUTH AFRICAN NATIONAL STANDARD Automotive diesel fuel Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001 tel: 012 428 7911

More information

Products for Asphalt Testing

Products for Asphalt Testing Products for Asphalt Testing For over 50 years, CANNON Instrument Company has provided asphalt testing labs with critical testing equipment and reagents including viscometers, flash point testers, constant

More information

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only. 9142-B-P-156/AF Field Metrology Well User s Guide Distribution is limited to DoD and U.S. DoD contractors only. May 2013 2013 Fluke Corporation. All rights reserved. Specifications are subject to change

More information

BOHLENDER GmbH Phone: +49(0)9346 / Fax: +49(0)9346 / Internet:

BOHLENDER GmbH Phone: +49(0)9346 / Fax: +49(0)9346 / Internet: Internet: www.bola.de E-Mail: info@bola.de BOLA-Flat Flange Distillation Apparatuses made of Fluoroplastic () with SAFE LAB-System 5 9 Suitable for the distillation of strong alkaline or acid products

More information

Operation and Instruction Manual

Operation and Instruction Manual K600X2 Heated Oil Test Centrifuge Operation and Instruction Manual REV B Koehler Instrument Company, Inc. 1595 Sycamore Avenue Bohemia, New York 11716-1796 USA Toll Free: 1-800-878-9070 (US only) Tel:

More information

orb effortless reactions Unrivalled quality» Intuitive design» Exceptional value

orb   effortless reactions Unrivalled quality» Intuitive design» Exceptional value orb effortless reactions www.syrris.com Unrivalled quality» Intuitive design» Exceptional value efforless reactions Benefits Quick vessel changes: The unique vessel clamp mechanism allows quick and easy

More information

FUELS. Test Methods

FUELS.  Test Methods FUELS s Page Oxidation Stability of Gasoline (Induction Period Method) ASTM D525, D873, D5304; IP 40, 138; ISO 7536 DIN 51799, 51780; FTM 791-3352, 791-3354...80-84 Oxidation Stability of Aviation Fuels

More information

Linetronic Technologies Laboratory and Process Analyzers Catalogue 2018

Linetronic Technologies Laboratory and Process Analyzers Catalogue 2018 Linetronic Technologies Laboratory and Process Analyzers Catalogue 2018 Table of contents Automatic Analysers Manual and Semi-automatic Analysers NewLab Aniline NewLab 100 Cloud Point NewLab 200 CFPP

More information

CTR* /117 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41 lt HYDRAULIC SYMBOL

CTR* /117 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41 lt HYDRAULIC SYMBOL 96 000/117 ED CTR* HYDRAULIC POWER UNITS TANK CAPACITY from 8 lt to 150 lt PUMP FLOW RATE from 1,6 lt to 41 lt DESCRIPTION The CTR* power units, are realised with a soaked gear pump and a vertically mounted

More information

USV Ultra Shear Viscometer

USV Ultra Shear Viscometer USV Ultra Shear Viscometer A computer controlled instrument capable of fully automatic viscosity measurements at 10,000,000 reciprocal seconds Viscosity measurement background Accurate measurement of dynamic

More information

SVM Stabinger Viscometer. ::: Viscometry at its best

SVM Stabinger Viscometer. ::: Viscometry at its best SVM 3000 Stabinger Viscometer ::: Viscometry at its best Small and Mighty The SVM 3000 Stabinger Viscometer is a rotational viscometer with a cylinder geometry. It is based on a modified Couette principle

More information

Shaking Incubators & Shakers

Shaking Incubators & Shakers Shaking Incubators & Shakers Bench Top Shaking Incubator LBSI Series Bench Top Shaking Incubator provides a controlled environment for continuous growth of biological organisms. LBSI Series has a wide

More information

ROTANTA 46 RSC ROBOTIC Robotic Centrifuge cooled

ROTANTA 46 RSC ROBOTIC Robotic Centrifuge cooled ROTANTA 46 RSC ROBOTIC Robotic Centrifuge cooled ROTANTA 46 RSC ROBOTIC Design The ROTANTA 46 RSC ROBOTIC is a refrigerated centrifuge with PC control and rotor positioning. It is ideal wherever sample

More information

Vessels and Distillation Equipment

Vessels and Distillation Equipment Vessels and Distillation Equipment 147 A suitable solution for practically every application in well-known BOLA-quality and optimally adapted to your needs. PRODUCT TIPS BOLA Scrubber Columns Pressure:

More information

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Model ED 720 Drying and heating chambers Classic.Line with natural convection Model ED 720 Drying and heating chambers Classic.Line with natural convection The strengths of a BINDER ED series drying chamber include routine drying and sterilization tasks up to 300 C. Thanks to the

More information

Low Speed Centrifuge www.labtron.com info@labtron.com Cyto-Low Speed Centrifuge LLS-A10 Cyto-low speed centrifuge has microprocessor controlled system with digital display to set RCF, speed and time required

More information

Safety drying oven with expended temperature range

Safety drying oven with expended temperature range MDL series 115 Safety drying ovens Safety drying oven with expended temperature range The BINDER MDL 115 with enhanced control function works at temperatures up to 350 C. This safety drying oven meets

More information