Clear View II. Simple Window Defrosting. Defroster Product Guide. Over 200 new sizes in 12 and 24 volt! Frost Fighter. Now 40% warmer. New!

Size: px
Start display at page:

Download "Clear View II. Simple Window Defrosting. Defroster Product Guide. Over 200 new sizes in 12 and 24 volt! Frost Fighter. Now 40% warmer. New!"

Transcription

1 New! Frost Fighter Clear View II Defroster installation and replacement made easy Simple Window Defrosting Defroster Over 200 new sizes in 12 and 24 volt! FROST FIGHTER Easy to install defrosters and controls with proven heating performance and a professional factory look. Clear View Defrosters reliably melt snow and ice even in the coldest winter conditions. Repair Kits Now 40% warmer Defroster Product Guide World leader in aftermarket defrosters and defroster control solutions in 12 and 24 volt Page 1 of 5

2 Defrosters made easy Simple Window Defrosting Frost Fighter Clear View II Defrosters match the heating performance of factory installed rear window defrosters, melting snow and ice in minutes. Cost effective and easy to install, new Clear View II defrosters provide full window coverage with an attractive factory appearance. Window Defrosting Anywhere Anyplace window defrosting is needed Clear View II defrosters are a simple and cost effective solution. Passenger cars Trucks Tractors Crane cabs Heavy equipment Snow moving equipment Ship cabins... many other applications How They Work Clear View defrosters have an electrical resistance which when powered provides the heat needed to clear windows of snow and ice in minutes. Heating is accomplished through contact between the defroster elements and the window. The defroster is connected electrically through the buss bar tabs to power and ground and activated with the automatic ThermaSync defroster control and switch. Easy Application Clear View heating elements come on prespaced rolls which are trimmed to length and applied directly on the window for a custom defroster fit. Complete Defrost Solutions Clear View II defrosters include ThermaSync controls and full wire harness installation kit. Individual defrosters and controls are also available. Connections The side buss bars include integral tabs positioned for easy connection to ThermaSync defroster controls or to existing defroster wiring. Finished Appearance Heating elements match the brownish color of factory defrosters and adhere directly to the glass for improved visibility and safe winter driving. No backing is left on the window to fade, crack or yellow. More Performance Clear View II feature improved defroster performance with a 40% increase in heating and more aggressive bonding technology for a new level of durability. New Defroster Sizes and Options ThermaSync controls modulate the input power and allow for many new defrosters sizes and options including flexible autooff timing and control of several defrosters with a single switch. Available in 12 and 24 volt. Frost Fighter Clear View Defrosters Ver Min Max Infrared image showing a Clear View II Defroster. Right side is on. Page 2 of 5

3 ThermaSync Defroster controls with smarts More options, less hassle New ThermaSync defroster controls are the perfect companion to Clear View II and other defrosters. They feature an easy to mount defroster switch with indicator light, adjustable automatic shut off timing, power modulation and can be used with the SwitchBoss to control multiple defrosters with a single switch. With the addition of a Switch Boss, ThermaSync controls can activate several defrosters at once through a single switch making the system ideal for multiple defroster installations like cabs. One Switch, Multiple Defrosters A single switch can activate several defrosters using Switch Boss. This network control is good for cabs and other applications the require several defrosters to be activated from a single switch. ThermaSync Switch Boss activates several defrosters from a single switch. Mounting The ThermaSync control can be secured out of sight under the dash while the defroster switch can be mounted in dash. ThermaSync Defroster Control and Switch Power Modulation ThermaSync Controls can modulate power to the defroster from 3% up to 100%. This feature allows for hundreds of new Clear View II defroster sizes to fit almost any window. New Voltages The Clear View II defrosters and ThermaSync controls are available in 12 and 24 volts. Nobody else does that! ThermaSync Control Operation Pressing the defrost symbol on the remote switch turns the defroster on. The defroster stays on until the switch is pressed again or the control times out. The timer can be set to time out from 10 to 160 minutes or can be left on indefinitely depending on the internal jumper settings. Each control comes with full instructions. Installation Options Clear View II Defrosters and ThermaSync Controls are available independently or with a full installation kit which includes the wire harness, fuse, switch mounting plate, power tap, wire ties, surface cleaner/adhesion promoter and full instructions. Complete defroster kit. Representative photo only. Actual parts may differ. See the Clear View Master Catalog which shows all the defroster sizes available Nautilus Court South, Suite 201 Boulder, CO Web: All rights reserved. Page 3 of 5

4 Ordering and FAQ How to order To order Clear View II Defrosters follow the steps below. Determine Defrost Area Take a look at the window to establish the defrost area. The elements do not need to completely fill the area to be effective. Measure Defrost Area Allow at least 1.5 inches (3.8) of clearance from the window edge. On vehicles with tightly curving windows the defroster should stop before the radius. Take back up lights into account. Defroster Area Important! The defroster height (top-to-bottom) is fixed by the number of grid lines and cannot be changed. The defroster width (side-to-side) can be trimmed within the minimum and maximum defroster sizes indicated. Select the Clear View Kit Select the defroster that fits the height (top-to-bottom) of the window. Then select the defroster width (side-toside) between the minimum and maximum width for the defroster. The height listed includes the tab ends which are 9/16 in (1.4 cm) top and bottom on the defroster. Full or Stick? Full Defrosters include a ThermaSync Control and Switch plus a complete installation kit and wire harness. Stick Kit Replacements include only the defroster and instructions. Stick Kits must use defrosters with 100% modulation. Defroster Repair Kits FROST FIGHTER Defroster Repair! Defroster repairs are easy with our full line repair kits including tab bonding, tab replacement, connectors, grid repair and many other solutions. What you need to know Doctor Defroster says... It really pays to understand the defroster before you start. Read the instructions, layout all the parts and the read the instructions again. - Doc On vehicles with tightly curving glass at the edges of the window the defroster should stop before the tight radius of the glass. The kits buss bars should be placed in the relatively flat area of the glass. The buss bars can be angled 1-3 inches to accommodate windows which are wider at the base. Clear View Stick Kit defrosters can be used to replace severely damaged defrosters that are not repairable using Frost Fighter repair kits. Stick kits include only the defroster and can be connected to the vehicles existing wiring. Stick kits require defrosters designed for 100% power modulation ONLY. Window tint removal can pull off the conductive defroster elements damaging it sometimes irreparably. Clear View defrosters cannot be applied over tint - but they can be tinted over. Something to Consider Clear View defrosters are engineered products and must be installed to the instructions. Changing the number of grid lines or layout may cause the defroster to fail. Please take the time when ordering to select the right defroster for the job Nautilus Court South Suite 201 Boulder, CO Web: Page 4 of 5

5 Technical Peak Current This is the current that is obtained by dividing the Voltage at the heater by the Resistance of the heater. It is important that the 25 ampere rating of the electronic switch not be exceeded. It is also important in calculating the voltage drop in the circuit feeding the heaters, and is independent of duty cycle. RMS Current This is the current that actually does the heating. It is obtained by multiplying the Peak Current times the square root of the duty cycle. To obtain adequate heat on the window, the RMS current needs to be at least 2.75 amperes in all conductors, and to prevent over heating the window, cannot be greater than 4.3 amperes in any conductor. Average Current This current represents the amount of drain on the battery. It is obtained by multiplying the Peak Current times the duty cycle. If the window is warmed for ten minutes without the engine running, the ampere-hour drain on the battery, the battery drain will never exceed a comfortable 4.2Ah. Changes and modifications Clear View II defrosters are engineered to deliver effective defrosting. Under no circumstance should the defroster layout or grid/buss bar layout be changed from the Clear View layout shown in the General Instructions and Attachment Two. The overall layout and number of grid lines MUST be maintained as per the instructions. ThermaSync solid-state controls allow for a range of automatic timing options and power settings which are normally set at the factory for optimum performance. Do not attempt to change the power modulation or timing without the proper reference guide available from Planned Products. Changing the power modulation will cause the defroster to fail. Clear View II defrosters are available in 12 and 24 volts. ThermaSync controls must match the voltage and power modulation of the defroster. ThermaSync controls are not required for Defrosters with 100% power modulation. Fuse Ratings Since fuses are sensitive to RMS current, recommended fuse ratings should be at least 20% higher that the RMS current. Standard automotive fuse ratings are 5.0A, 7.5A, 10A, 15A, 20A, 25A and 30A. So the recommended fuse rating is obtained by multiplying the maximum RMS current times 1.2 and selecting the next higher fuse. Duty Cycle Duty Cycle is defined as the time that the heater is ON divided by the time the heater is OFF plus the time the heater is ON, and is generally express in percent. If the heater is ON all the time, the duty cycle is said to be 100%. Part Numbers Clear View defrosters have a simple part numbering set up L - STK Stick Kit Defroster (if available) Tab Position (all tabs on left) Minimum and Maximum Length Defroster Elements Voltage Instructions These instructions come in two parts, General Instructions and Attachment Two which is specific to each defroster. These instructions are fully illustrated in an easy to follow step-by-step format Nautilus Court S. Suite 201 Boulder, CO Web: Page 5 of 5 2

Wiper Parking Area Defrosters

Wiper Parking Area Defrosters Clear View II FWH HD Wiper Parking Area High density elements for better heating Defrost the windshield low in the wiper parking area Keep wipers moving, cut snow build up In tough winter conditions snow

More information

Renewable Energy. Presented by Sean Flanagan

Renewable Energy. Presented by Sean Flanagan Renewable Energy Presented by Sean Flanagan Background Flanagan and Sun since 2004 Solar electric (PV) off grid and grid tie, solar thermal, pool heating, solar air heating, small wind turbines, microhydro

More information

RH INSTALL INSTRUCTIONS

RH INSTALL INSTRUCTIONS Tips for Installing Rhinogear Products The recommended sequence for installing our Rhinogear line of products on your Rhino. This sequence will help with ease of installation and help save time by eliminating

More information

ThermoLite 110W-330W Solar Panel Installation Instructions

ThermoLite 110W-330W Solar Panel Installation Instructions ThermoLite 110W-330W Solar Panel Installation Instructions INSTALL APPLICATIONS SUPPORTED BY THIS GUIDE: 1. Trailer Roof Top Mounted 2. Bus Roof Top Mounted 3. Tractor Fairing Mounted 40W and 110W Replacement

More information

DCDC-USB V high power, Intelligent DC-DC converter with USB interface

DCDC-USB V high power, Intelligent DC-DC converter with USB interface DCDC-USB-2 6-34V high power, Intelligent DC-DC converter with USB interface Quick Installation Guide Version 1.c P/N DCDC-USB-2 Introduction The DCDC-USB-2 is a powerful DC-DC power supply designed to

More information

s_enn Exterior Stainless Steel Shading System by Draper

s_enn Exterior Stainless Steel Shading System by Draper Installation Instructions s_enn Exterior Stainless Steel Shading System by Draper Caution 1 Never push the bottom rail of the system up by hand. This can cause irreparable damage. Access equipment must

More information

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB DCDC-USB 6-34V 10A, Intelligent DC-DC converter with USB interface Quick Installation Guide Version 1.0c P/N DCDC-USB Introduction The DCDC-USB is a small yet powerful DC-DC power supply designed to power

More information

innovations in battery charging

innovations in battery charging innovations in battery charging AutomaticBatteryCharger forsealed or Valve Regulated Lead-Acid Batteries Model HPX-60 Series OperatingInstructions WARNING CONCERNING THE REMOVAL OF COVER: CAUTION: TO PREVENT

More information

1963 GEN IV SUREFIT VINTAGE AIR CONDITIONING INSTALLATION

1963 GEN IV SUREFIT VINTAGE AIR CONDITIONING INSTALLATION by Randy Irwin 1963 GEN IV SUREFIT VINTAGE AIR CONDITIONING INSTALLATION Randy Irwin - Technical Writer Randy has been involved in the Chevy parts business for over 30 years. He is a wizard at creating,

More information

innovations in battery charging

innovations in battery charging innovations in battery charging AutomaticBattery Charger for Sealed or Valve Regulated Lead-AcidBatteries Model HPX-10 Series OperatingInstructions POWER/FLOAT FAST CHARGE FAULT (shorted or reversed output

More information

301.4C. Mini Hydraulic Excavator

301.4C. Mini Hydraulic Excavator 301.4C Mini Hydraulic Excavator Engine Net Power 13.2 kw 17.7 hp Weight Transport Weight with Canopy 1380 kg 3,042 lb Transport Weight with Cab 1470 kg 3,241 lb Versatility Easy to transport and greater

More information

Car Battery Charger Instructions for Use

Car Battery Charger Instructions for Use BATTERY CHARGER 12Volt 4Amp FOR INDOOR USE ONLY Power Details: Input: 230-240Vac; 50Hz; 52W Output: 12V DC; 2.8A Maximum Charge Rate: 4A RMS Read these instructions before operating this car battery charger

More information

301.4C. Mini Hydraulic Excavator

301.4C. Mini Hydraulic Excavator 301.4C Mini Hydraulic Excavator Engine Gross Power 17.9 kw 24.3 hp Weight Transport Weight with Canopy 1380 kg 3,042 lb Transport Weight with Cab 1470 kg 3,241 lb Versatility Easy to transport and greater

More information

Installation Example and Guide

Installation Example and Guide Installation Example and Guide Author: Road Angel Group Date: May 2016 Version: 1.00 Version 1.00 Page 1 of 12 Contents CONTENTS... 2 INTRODUCTION... 3 SCOPE... 3 ITEMS REQUIRED FOR HARDWIRE INSTALLATION...

More information

POWER DISTRIBUTION SYSTEMS

POWER DISTRIBUTION SYSTEMS DN POWER DISTRIBUTION SYSTEMS 8O - 1 POWER DISTRIBUTION SYSTEMS TABLE OF CONTENTS page AND POWER DISTRIBUTION SYSTEM....1 POWER DISTRIBUTION CENTER...1 GENERATOR CARTRIDGE FUSE....2 JUNCTION BLOCK...2

More information

INSTALL INSTRUCTIONS

INSTALL INSTRUCTIONS INSTALL INSTRUCTIONS Models: 6005 & 6005TK (For Non Electric Mirrors) GM CK Body Style If your stock mirrors are stock electric the wrong set has been ordered. Do not attempt to manually extend or retract

More information

INTRODUCTION. During inclement winter weather the silicone is heated with our heating technology to mantain the same visibility as warm weather.

INTRODUCTION. During inclement winter weather the silicone is heated with our heating technology to mantain the same visibility as warm weather. INTRODUCTION THERMALBLADE products deliver an upgrade in performance to help you see better in all weather. The squeegee of all THERMALBLADES are made of silicone, which ensures greater visibility by applying

More information

FACTORY AIR CONVERSION HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE

FACTORY AIR CONVERSION HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle FACTORY AIR CONVERSION HEAT/ COOL/ DEFROST 1970-72 CHEVROLET CHEVELLE CONTROL & OPERATING INSTRUCTIONS The controls on your

More information

PLEASE READ BEFORE CALLING OR RETURNING PRODUCT. EXTREMELY IMPORTANT!!!

PLEASE READ BEFORE CALLING OR RETURNING PRODUCT. EXTREMELY IMPORTANT!!! Thank you for your purchase of WeaponX Smart Direct Fire Ignition Coil System for your vehicle. The following are the instruction manuals for your ignition system kit. Please read carefully and enjoy your

More information

Revolutionary design gives you a real world COMPETITIVE ADVANTAGE.

Revolutionary design gives you a real world COMPETITIVE ADVANTAGE. Revolutionary design gives you a real world COMPETITIVE ADVANTAGE. Lightest trailers in their class Biggest payloads in their class Advanced unitized technology Superior durability Unparalleled safety

More information

Capabilities. Solutions. for Commercial Vehicle Applications. Inside: Vol. 2, No. 1 June Lincoln Advantage pg. 2. It s Your Choice pg.

Capabilities. Solutions. for Commercial Vehicle Applications. Inside: Vol. 2, No. 1 June Lincoln Advantage pg. 2. It s Your Choice pg. Vol. 2, No. 1 June 2003 INFORMATION FROM THE LEADER IN THE LUBRICATION INDUSTRY Solutions for Commercial Vehicle Applications Inside: Lincoln Advantage pg. 2 It s Your Choice pg. 3 On-Road Applications

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Models: 7105 & 7105TK Dodge Ram 1500 ('02 Current) Ram 2500 & 3500 '03 - Current with stock manual mirrors. IF YOU DO NOT CURRENTLY HAVE MANUAL MIRRORS, THE WRONG SET HAS BEEN

More information

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC-124000A OPERATING PROCEDURES AND SAFETY INSTRUCTIONS CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER NO USER

More information

MUNICIPAL ATTACHMENTS

MUNICIPAL ATTACHMENTS MUNICIPAL ATTACHMENTS www.amiattachments.com GRAPTOR BUCKET When you need to pick up large, heavy objects or grab bucketfuls of debris, get a tighter grip on productivity with AMI s Graptor Bucket. The

More information

TABLE OF CONTENTS INTRODUCTION 3. INSTALLATION PROCEDURES Air Conditioner Location 4. A/C Ducting Installation 5

TABLE OF CONTENTS INTRODUCTION 3. INSTALLATION PROCEDURES Air Conditioner Location 4. A/C Ducting Installation 5 585474 1 TABLE OF CONTENTS SECTION PAGE INTRODUCTION 3 INSTALLATION PROCEDURES Air Conditioner Location 4 Air Conditioner Mounting 4 A/C Ducting Installation 5 Power Kit Installation (Batteries). 5 Separator...

More information

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter. OWNER S MANUAL DP AUDIO Model No. DN350 12 Volt DC to 115 Volt AC 150 WATT 300WATT HIGH SURGE POWER INVERTER Please read installation and operation instruction before using this Power inverter. Contents

More information

DX50 PNEUMATIC TIRE FORKLIFT. The Forklift With Proven Ability. 15,400 18,000 LBS. CAPACITY DIESEL

DX50 PNEUMATIC TIRE FORKLIFT. The Forklift With Proven Ability. 15,400 18,000 LBS. CAPACITY DIESEL DX50 The Forklift With Proven Ability. PNEUMATIC TIRE FORKLIFT 15,400 18,000 LBS. CAPACITY DIESEL "Reducing Total Operating Costs" with Komatsu Innovative Technologies Komatsu's Hydraulic System and the

More information

RH INSTALL INSTRUCTIONS 2008 MODEL

RH INSTALL INSTRUCTIONS 2008 MODEL RH-800-2 INSTALL INSTRUCTIONS 2008 MODEL 1 Tips for Installing Rhinogear Products The recommended sequence for installing our Rhinogear line of products on your Rhino. This sequence will help with ease

More information

Water in Fuel Sensor Kit

Water in Fuel Sensor Kit 03/08/2016 1050355-1050356 Water in Fuel Sensor Kit (I-00369) 1 Water in Fuel Sensor Kit Fast and Accurate Detection of Water in Diesel Fuel 1050355 Universal Kit For use with BD FlowMax water separator

More information

Remote Start Kit for GM Installation RS1/3/4/7 + ADS-DL Tip Sheet

Remote Start Kit for GM Installation RS1/3/4/7 + ADS-DL Tip Sheet Remote Start Kit for GM Installation RS1/3/4/7 + ADS-DL Tip Sheet rev 1.4 12/16/2013 Thank you for purchasing your remote start from MyPushcart.com - an industry leader in providing remote starts to do-it-yourself

More information

Business unit names, building names, addresses and directions are not permitted on the primary monolith. Examples are shown in the Monolith section.

Business unit names, building names, addresses and directions are not permitted on the primary monolith. Examples are shown in the Monolith section. Distribution / Signage Requirements Primary Monolith Primary signage features only the Cummins logo and is required for all locations unless an exception is granted. Exceptions will be granted for locations

More information

JLG UTILITY VEHICLES

JLG UTILITY VEHICLES JLG UTILITY VEHICLES 1 MORE MATERIALS. MORE PEOPLE. ONLY IN YOUR JLG UTV. With a rugged design, heavy-duty drive system and class-leading cargo capacity, JLG utility vehicles outlast the competition and

More information

I m going to come out and say it so you keep reading. What you were taught about hard start kits decreasing inrush amperage is wrong.

I m going to come out and say it so you keep reading. What you were taught about hard start kits decreasing inrush amperage is wrong. Start Capacitor & Inrush, Facts & Myths Part 4 Now is the part where we get specific about Start capacitors and inrush. If you haven t read the first three parts please do so before reading this one or

More information

WPS-104 Heater Installation Instructions For 500EFI, 700 XP, & Crew Applications

WPS-104 Heater Installation Instructions For 500EFI, 700 XP, & Crew Applications WPS-104 Heater Installation Instructions For 500EFI, 700 XP, & Crew Applications ORDER OF INSTALLATION FOR A COMPLETE ENCLOSURE OF A RANGERWARE WPS (Weather Protection System) IS AS FOLLOWS: 1. Heater

More information

Wear Protection ESCO Kwik-Lok Application Guide for Crushing and Conveying P6001UWS01L0312

Wear Protection ESCO Kwik-Lok Application Guide for Crushing and Conveying P6001UWS01L0312 ESCO Kwik-Lok Wear Protection Application Guide for Crushing and Conveying P6001UWS01L0312 Safety www.escocorp.com General Safety Information The safety practices described in this manual are meant as

More information

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M S m a r t e r Q u i e t e r M o r e A c c u r a t e U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M Installation Manual PASSPORT 9500ci Comes Complete Front Radar Receiver Miniature weatherproof

More information

INSTALLATION GUIDE. Dynojet Research 2191 Mendenhall Drive Suite 105, North Las Vegas NV,

INSTALLATION GUIDE.   Dynojet Research 2191 Mendenhall Drive Suite 105, North Las Vegas NV, INSTALLATION GUIDE www.dynojetwb2.com Dynojet Research 2191 Mendenhall Drive Suite 105, North Las Vegas NV, 89081 1-800-992-4993 2008 Dynojet Research, Inc. All Rights Reserved. Wideband 2 Installation

More information

RH INSTALLATION INSTRUCTIONS 2

RH INSTALLATION INSTRUCTIONS 2 Tips for Installing Rhinogear Products The recommended sequence for installing our Rhinogear line of products on your Rhino. This sequence will help with ease of installation and help save time by eliminating

More information

Consists of. Date:17/02/2011 Page 1/8

Consists of. Date:17/02/2011 Page 1/8 Consists of 470518 Qty. Product 4 1 DEFA Termina - interior heater with holder 1 1 DEFA Futura - time program controller/timer 3 1 DEFA MultiCharger 1203 - battery charger/relay 6 1 DEFA Extension cable

More information

EFFICIENCY AND POWER 3,000 4,000 LB. CAPACITY ELECTRIC PNEUMATIC TIRE LIFT TRUCKS

EFFICIENCY AND POWER 3,000 4,000 LB. CAPACITY ELECTRIC PNEUMATIC TIRE LIFT TRUCKS EFFICIENCY AND POWER 3,000 4,000 LB. CAPACITY ELECTRIC PNEUMATIC TIRE LIFT TRUCKS 2 A POWERFUL SOLUTION 3 Maximum Performance: Shift After Shift The Cat EPC3000 EP4000 series is designed for efficiency

More information

SRX Corvette C-6 Installation Tips

SRX Corvette C-6 Installation Tips SRX INSTALLED RADAR & LASER DEFENSE SYSTEM by ESCORT SRX Corvette C-6 Installation Tips We recommend bench assembling the entire system if you are a first time installer. We also recommend reading the

More information

DIESEL FIRED COOLANT HEATERS

DIESEL FIRED COOLANT HEATERS DIESEL FIRED COOLANT HEATERS Coolant heaters work independently of the engine and thus offer a double plus: pre-heating the vehicle s passenger compartment and the engine. The heaters are integrated in

More information

OWNERS MANUAL EC-90 BATTERY SYSTEM

OWNERS MANUAL EC-90 BATTERY SYSTEM OWNERS MANUAL EC-90 BATTERY SYSTEM PO BOX 956 Boulder, CO 80306-0956 web site: www.ecocharge.com e-mail: mail@ecocharge.com voice: 303.449.5761 fax: 303.449.1545 Revision A November, 2002 Copyright 2002,

More information

Be Ready for Anything.

Be Ready for Anything. Be Ready for Anything. COMPRESSOR GENERATOR WELDER BATTERY CHARGER BATTERY BOOSTER PTO PORT...OR BUILD YOUR OWN! MODULAR MULTIFUNCTION DIESEL DRIVE MODULAR DIESEL DRIVE DIESEL DRIVE MODULAR HOW CAN THE

More information

INSTALLATION INSTRUCTIONS:

INSTALLATION INSTRUCTIONS: INSTALLATION INSTRUCTIONS: The CA-5030 is an ultrasonic parking assist system designed for use on the rear bumper of most cars and trucks. This system detects any people or objects behind the vehicle using

More information

Retro it Steering Column

Retro it Steering Column Retro it Steering Column INSTALLATION INSTRUCTIONS for 1970-74 Cuda/Challenger FOR PART NUMBER S: 1620810010, 1620810020, 1620810051, 1620820010, 1620820020, 1620820051 S I NCE 1986 Instruction # 8000000005

More information

The Mark V Air/Fuel Controller - Technical Manual -

The Mark V Air/Fuel Controller - Technical Manual - Neutronics Enterprises Inc. The Mark V Air/Fuel Controller - Technical Manual - For Technical Information contact: Neutronics Enterprises Inc. 11421 West Bernardo Court. San Diego, CA. 92127 (858) 674-2250

More information

GMTRK1 BOLT-ON TRAIN HORN SYSTEM INSTALLATION INSTRUCTIONS. For GM & GMC Trucks & SUVS

GMTRK1 BOLT-ON TRAIN HORN SYSTEM INSTALLATION INSTRUCTIONS. For GM & GMC Trucks & SUVS GMTRK1 BOLT-ON TRAIN HORN SYSTEM INSTALLATION INSTRUCTIONS For 2007-2017 GM & GMC Trucks & SUVS The GMTRK-1 System comes with a custom battery tray to hold the air compressor and air tank. The horns will

More information

TOYOTA LANCRUISER 79 SERIES (2007 to PRESENT) 110lt AUXILIARY TANK AUXILIARY FUEL TANK PARTS LIST AND FITTING INSTRUCTIONS PART NUMBER: TL79A2

TOYOTA LANCRUISER 79 SERIES (2007 to PRESENT) 110lt AUXILIARY TANK AUXILIARY FUEL TANK PARTS LIST AND FITTING INSTRUCTIONS PART NUMBER: TL79A2 Copyright This document contains technical information the property of TOYOTA LANCRUISER 79 SERIES (2007 to PRESENT) 110lt AUXILIARY TANK AUXILIARY FUEL TANK PARTS LIST AND FITTING INSTRUCTIONS PART NUMBER:

More information

Inverter User Manual

Inverter User Manual Inverter User Manual -------------for standard model DC TO AC Power Inverter CONTENTS Safety First 1. Introduction 2. Installation Guidelines 3. Using the inverter 4. Troubleshooting 5. Specifications

More information

INSTALLATION GUIDE. AV8900H Dual Multimedia Headrest Replacement System

INSTALLATION GUIDE. AV8900H Dual Multimedia Headrest Replacement System INSTALLATION GUIDE AV8900H Dual Multimedia Headrest Replacement System NOTICE OF INTENDED INSTALLATION AND USE AV8900H VIDEO PRODUCTS ARE NOT INTENDED FOR VIEWING BY THE DRIVER, AND ARE TO BE INSTALLED

More information

READY TO GO WITH CALIX

READY TO GO WITH CALIX READY TO GO WITH CALIX Battery charger range www.calix.se 1 CONTENTS Who needs a battery charger?... 3 Cars... 4 Buses & trucks... 5 Agricultural machinery... 6 Construction machinery... 7 Industrial...

More information

INSTALLATION GUIDE AV7900 Dual Multimedia Headrest Replacement System

INSTALLATION GUIDE AV7900 Dual Multimedia Headrest Replacement System INSTALLATION GUIDE AV7900 Dual Multimedia Headrest Replacement System NOTICE OF INTENDED INSTALLATION AND USE AV7900 VIDEO PRODUCTS ARE NOT INTENDED FOR VIEWING BY THE DRIVER, AND ARE TO BE INSTALLED ONLY

More information

PRODUCT OVERVIEW.

PRODUCT OVERVIEW. PRODUCT OVERVIEW www.weldco-hydralift.com CONTENTS WHL23TC60/75/100...4 HL30TC70...8 OUR PRODUCTS Weldco Hydra-Lift manufactures truck mounted telescopic cranes ranging from 23-ton to 50-ton capacities.

More information

Ag Leader Technology. Combine Installation New Holland TC 57, 59. Monitor Installation

Ag Leader Technology. Combine Installation New Holland TC 57, 59. Monitor Installation Monitor Installation Figure 1. Monitor installed on right side cab window using window mount bracket. 1. If you are in very humid conditions where moisture may condense on the glass where you are mounting

More information

Rzr Heater System Part #

Rzr Heater System Part # Rzr Heater System Part # 2878135 NOTE: This heater unit installs below the center of the dash. If you have a radio mount kit (Polaris Part # 2876897) you may need to cut the top front corner off the mount

More information

High Profile Evaporator

High Profile Evaporator High Profile orator PRODUCT DATA & INSTALLATION Bulletin K30-KHPHG-PDI-3 Part # 1081591 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Low & Medium Hot Gas Defrost

More information

DELIVERING MORE 7,000 11,000 LB. CAPACITY ELECTRIC PNEUMATIC TIRE LIFT TRUCKS

DELIVERING MORE 7,000 11,000 LB. CAPACITY ELECTRIC PNEUMATIC TIRE LIFT TRUCKS DELIVERING MORE 7,000 11,000 LB. CAPACITY ELECTRIC PNEUMATIC TIRE LIFT TRUCKS 2 MORE Moving Your Business Forward The 2EPC7000-2EP11000 series from Cat Lift Trucks is built to perform. Delivering all of

More information

MP V 8A Electronic Smart Charger. Instruction and Information Manual

MP V 8A Electronic Smart Charger. Instruction and Information Manual MP7428 12V 8A Electronic Smart Charger Instruction and Information Manual In order to ensure correct and safe usage of your battery charger, you should read these instructions carefully. Please retain

More information

ELECTRICALLY HEATED SYSTEMS

ELECTRICALLY HEATED SYSTEMS DN ELECTRICALLY HEATED SYSTEMS 8N - 1 ELECTRICALLY HEATED SYSTEMS TABLE OF CONTENTS page GENERAL INFORMATION INTRODUCTION...1 REAR WINDOW DEFOGGER SYSTEM...1 HEATED MIRROR SYSTEM...1 DESCRIPTION AND OPERATION

More information

Parts & Service Information K810054C PRODUCT IMPROVEMENT

Parts & Service Information K810054C PRODUCT IMPROVEMENT Parts & Service Information K810054C Disclaimer: This bulletin release is for informational purposes only and is not factory authorization for warranty repairs or warranty claim submission. PRODUCT IMPROVEMENT

More information

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC-122000A AND PSC-241000A Operating Instructions WARNING CONCERNING THE REMOVAL OF COVER: CAUTION: TO PREVENT THE RISK OF ELECTRIC

More information

POWERED RUNNING BOARDS INSTALLATION MANUAL

POWERED RUNNING BOARDS INSTALLATION MANUAL POWE RUNNING BOARDS INSTALLATION MANUAL Level of Difficulty Moderate Parts List 1 Driver / left running board* 1 Passenger / right running board* 4 Mounting bracket, standard 2 Mounting bracket, middle

More information

Grid Heater Starting Aid (T000)

Grid Heater Starting Aid (T000) Page 1 of 14 Topic No. Rev. Level Topic Date Group No. 94T13-2 01-May-1994 13 Expiration Date (U.S. and Canada): Expiration Date (International): Engine Family 6B, ISB, QSB5.9, B5.9 Fuel System Plant From

More information

AP255E Cat C2.2 Engine Operating Weight Paving Widths

AP255E Cat C2.2 Engine Operating Weight Paving Widths R AP255E Paver Cat C2.2 Engine Gross Power 34.1 kw 46 hp (m) 45 hp (I) Operating Weight w/as3143 Screed 4500 kg 9,921 lb Paving Widths Standard Extendable Range 1400 mm - 2600 mm 4 7" - 8 6" Maximum w/extensions

More information

REAL POWER. REAL SOLUTIONS. 3,000 4,000 LB. CAPACITY 3-WHEEL ELECTRIC PNEUMATIC TIRE LIFT TRUCKS

REAL POWER. REAL SOLUTIONS. 3,000 4,000 LB. CAPACITY 3-WHEEL ELECTRIC PNEUMATIC TIRE LIFT TRUCKS REAL POWER. REAL SOLUTIONS. 3,000 4,000 LB. CAPACITY 3-WHEEL ELECTRIC PNEUMATIC TIRE LIFT TRUCKS 2 TOTAL CONTROL Delivering Premium Performance The Cat EP16PNT-EP20PNT electric pneumatic tire series is

More information

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W Instruction Manual Introduction The AIMS Power 5000 Watt series inverters are the most advanced line of mobile DC to AC power

More information

INSTALLATION & OWNER S MANUAL

INSTALLATION & OWNER S MANUAL INSTALLATION & OWNER S MANUAL CAB INSTALLATION INSTRUCTIONS MASSEY FERGUSON TGX SERIES SOFT SIDED CAB ENCLOSURE (p/n MFTGXSS) This Curtis Cab is designed and manufactured for use only as reasonable weather

More information

1. SPECIFICATION

1. SPECIFICATION 000000 093 1. SPECIFICATION Specification HPS EPS Alternator Crankshaft pulley : Alternator Pulley 1 : 2.94 Normal output (idling/2200 rpm) 70/120 A 70/140A Regulator voltage 14.6 V Brush Length 12.5 mm

More information

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY EXHAUST BRAKES C40019 1999-2003 FORD F250 / F350 7.3L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY Getting Started Thank you and congratulations on your purchase of a Pacbrake exhaust retarder.

More information

HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM. Parts List and Installation Instructions CAUTION

HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM. Parts List and Installation Instructions CAUTION May 1, 2018 Lit. No. 92991, Rev. 00 HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM Parts List and Installation Instructions Read this document before installing the snowplow. See your sales outlet/website

More information

FORM NO. HSC-543 AIR HANDLERS

FORM NO. HSC-543 AIR HANDLERS FORM NO. HSC- AIR HANDLERS AH10X1 High Efficiency featuring New Industry Standard R-10A Refrigerant Features AH10X1 features the new X-1 (ECM) motor which provides enhanced SEER performance with most Sure

More information

GTX GEX. 16/18/20s ELECTRIC 48 VOLT 3-WHEEL/4-WHEEL / 1800 / 2000 kg 3200 / 3600 / 4000 lbs.

GTX GEX. 16/18/20s ELECTRIC 48 VOLT 3-WHEEL/4-WHEEL / 1800 / 2000 kg 3200 / 3600 / 4000 lbs. GTX GEX 16/18/20s 3-WHEEL/4-WHEEL ELECTRIC 48 VOLT 1600 / 1800 / 2000 kg 3200 / 3600 / 4000 lbs. Superelastic tyres provide a soft ride and allow for indoor/outdoor operation. 410 mm The low step height

More information

FOUR-ON-THE SNOW Newsletter

FOUR-ON-THE SNOW Newsletter FOUR-ON-THE SNOW Newsletter A publication of Tucker Sno-Cat Corporation Made in the USA since 1942 NO SNOW TOO DEEP NO ROAD TOO STEEP December 2013 Volume 5 Issue 12 COLD FLUIDS Cold fluid can cause failures

More information

PFadvantage MF 6850/6855; Ideal 9080/9090

PFadvantage MF 6850/6855; Ideal 9080/9090 MF 6850/6855; Ideal 9080/9090 Note: Indented items indicate parts included in an Quantity by Model assembly listed above MF Ideal Part Name/Description Part Number 6850 6855 9080 9090 Instruction Kit MF

More information

INSTALLATION GUIDE Car Show Dual DVD Headrest Replacement System

INSTALLATION GUIDE Car Show Dual DVD Headrest Replacement System INSTALLATION GUIDE Car Show Dual DVD Headrest Replacement System NOTICE OF INTENDED INSTALLATION AND USE CAR SHOW VIDEO PRODUCTS ARE NOT INTENDED FOR VIEWING BY THE DRIVER, AND ARE TO BE INSTALLED ONLY

More information

Pub Mounting Instructions For Automotive GPS Receivers

Pub Mounting Instructions For Automotive GPS Receivers Pub. 988-0154-631 Mounting Instructions For Automotive GPS Receivers This instruction sheet describes how to assemble and use the quickrelease flexible suction cup mount for Lowrance automotive GPS receivers.

More information

Recommended Tools: Phillips & Flat Screwdriver, 17/13/10mm wrench, 8mm nut driver

Recommended Tools: Phillips & Flat Screwdriver, 17/13/10mm wrench, 8mm nut driver RPSTL48 RemotePro Remote Power System Wireless Base Stations and Client Devices Surveillance Cameras Remote Sensors Remote Lighting Off Grid Electronics Congratulations! on your purchase of the RemotePro

More information

Load Side PV Connections

Load Side PV Connections Perspectives on PV Load Side PV Connections 705.12(D) in the 2014 NEC by John Wiles Through the exceptional efforts of the members of NFPA NEC Code-Making Panel 4 working with the proposals and comments

More information

USER MANUAL QUICK INSTALLATION GUIDE MRGB65B

USER MANUAL QUICK INSTALLATION GUIDE MRGB65B USER MANUAL QUICK INSTALLATION GUIDE MRGB65B MARINE GRADE RGB 6.5 COAX SPEAKERS USER MANUAL QUICK INSTALLATION GUIDE MRGB65B MARINE GRADE 6.5 COAX SPEAKERS BOSS Audio Systems 3451 Lunar Court Oxnard, CA

More information

High Profile Evaporator

High Profile Evaporator PRODUCT DATA & INSTALLATION Bulletin K30-KHPE-PDI-3 Part # 1081588 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile orator Low & Medium Temperature Electric

More information

ROADMASTER, Inc NE 127th Ave. Vancouver, WA Fax roadmasterinc.com ROADMASTER, Inc.

ROADMASTER, Inc NE 127th Ave. Vancouver, WA Fax roadmasterinc.com ROADMASTER, Inc. ROADMASTER, Inc. 6110 NE 127th Ave. Vancouver, WA 98682 800-669-9690 Fax 360-735-9300 roadmasterinc.com 2008-2017 ROADMASTER, Inc. All rights reserved. 853600-05 11/17 Read all instructions before installing

More information

PowerFlo 50 Parts List/Assembly Instructions/Users Guide ***PLEASE READ ALL INSTRUCTIONS CAREFULLY AND THOROUGHLY***

PowerFlo 50 Parts List/Assembly Instructions/Users Guide ***PLEASE READ ALL INSTRUCTIONS CAREFULLY AND THOROUGHLY*** PowerFlo 50 Parts List/Assembly Instructions/Users Guide ***PLEASE READ ALL INSTRUCTIONS CAREFULLY AND THOROUGHLY*** Owners Manual (Please check to make sure to locate all parts before assembly.) 11/12/2008

More information

Trucking Info: Equipment 7 Factors to Consider When Installing an Inverter

Trucking Info: Equipment 7 Factors to Consider When Installing an Inverter Trucking Info: Equipment 7 Factors to Consider When Installing an Inverter From what size to get to company policies, what fleets need to know when choosing and installing a power inverter. September 2013,

More information

K SERIES CRAWLER DOZERS 1850K

K SERIES CRAWLER DOZERS 1850K K SERIES CRAWLER DOZERS 1850K K Series Dozers CUSTOMER SUPPORT The Case dealer: Your professional partner Start with world-class Case machinery and attachments Your Case dealer will help you work smarter

More information

300.9D. Mini Hydraulic Excavator

300.9D. Mini Hydraulic Excavator 300.9D Mini Hydraulic Excavator Engine Gross Power (ISO 14396) 13.7 kw 18 hp Net Power 9.6 kw 13 hp Weight Operating weight without Safety frame 935 kg 2,061 lb Operating weight with Safety frame 985 kg

More information

16/18/20s ELECTRIC 48 VOLT. (3200 / 3600 / 4000 lbs.) 3-WHEEL/4-WHEEL / 1800 / 2000 kg

16/18/20s ELECTRIC 48 VOLT. (3200 / 3600 / 4000 lbs.) 3-WHEEL/4-WHEEL / 1800 / 2000 kg GT TX X GE EX X 16/18/20s 3-WHEEL/4-WHEEL ELECTRIC 48 VOLT 1600 / 1800 / 2000 kg (3200 / 3600 / 4000 lbs.) Superelastic tyres provide a soft ride and allow for indoor/outdoor operation. 410 mm The low

More information

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. 24V DC-CW332 DOC531/11 Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c. To obtain the best performance from your Pressurised water

More information

RTC ton (16t) RTC ton (18t) RTC ton (20t)

RTC ton (16t) RTC ton (18t) RTC ton (20t) RTC-8018 18-ton (16t) RTC-8020 20-ton (18t) RTC-8022 22-ton (20t) Hydraulic Rough Terrain Cranes 121' (36.88 m) on-board tip height Confined Area Lifting Capacities (CALC TM ) System Piston winches Rated

More information

AC SERIES ADJUSTABLE CONCEALED LOW VOLTAGE STRIP FOR ADJUSTABLE SHELVES

AC SERIES ADJUSTABLE CONCEALED LOW VOLTAGE STRIP FOR ADJUSTABLE SHELVES TRIM LAMP LAMP OPERATING SERIES PROFILE VOLTAGE AC 0. AC SERIES ADJUSTABLE CONCEALED LOW VOLTAGE FOR ADJUSTABLE SHELVES 7 700K V 7 700K V 00K V 00K V 0 000K V 0 000K V US ETL LISTED, MISCELLANEOUS FITURES,

More information

Centrifugal Constant Pressure Control

Centrifugal Constant Pressure Control Operating Instructions & Parts Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

More information

NEW HOLLAND SERIES TT

NEW HOLLAND SERIES TT NEW HOLLAND SERIES TT TT55 TT75 THE NEW HOLLAND BRAND. MODERN STYLE AND GREAT DYNAMICS Comfort to enhance productivity A general-purpose tractor needs to satisfy differing demands. During some operations

More information

Please read thoroughly before starting installation and check that kit contents are complete.

Please read thoroughly before starting installation and check that kit contents are complete. Rear Vision System Mirror Display 2013-Current Ram (Kit part number 1009-9518) Please read thoroughly before starting installation and check that kit contents are complete. Items Included in the Kit: Rear

More information

ALTERNATOR DE-EXCITATION WITH K1 AND K2 ON ANALOGUE

ALTERNATOR DE-EXCITATION WITH K1 AND K2 ON ANALOGUE Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 023 AVR Features ALTERNATOR DE-EXCITATION WITH K1 AND K2 ON ANALOGUE AVRs On STAMFORD alternators, analogue AVR

More information

TIP SHEET. Installation Tips for your RS OL-MDB-CH6 (1) (for Jeep vehicles) T1227 v1.0 3/19/14

TIP SHEET. Installation Tips for your RS OL-MDB-CH6 (1) (for Jeep vehicles) T1227 v1.0 3/19/14 TIP SHEET Installation Tips for your RS-360 + OL-MDB-CH6 (1) (for Jeep vehicles) T1227 v1.0 3/19/14 Thank you for purchasing your remote start from MyPushcart.com - an industry leader in providing remote

More information

PerfectPass Digital Pro Installation Instructions

PerfectPass Digital Pro Installation Instructions PerfectPass Digital Pro Installation Instructions Step 1. Installation of Servo Motor Using the two provided hose clamps, loosely mount the servo motor on top of cooling water hose leading to drivers side

More information

New Holland TC30 Parts List & Mounting Instructions

New Holland TC30 Parts List & Mounting Instructions New Holland TC30 Parts List & Mounting Instructions Jodale Perry Printed: 2003/07 Standard Parts List Qty Description Photo Front Brackets 4 Front Bracket Spacers Rear Brackets Rear Bracket Axle Supports

More information

Reference: Photovoltaic Systems, p References: Photovoltaic Systems, Chap. 7 National Electrical Code (NEC), Articles 110,

Reference: Photovoltaic Systems, p References: Photovoltaic Systems, Chap. 7 National Electrical Code (NEC), Articles 110, Charge controllers are required in most PV systems using a battery to protect against battery overcharging and overdischarging. There are different types of charge controller design, and their specifications

More information

Installation Instructions

Installation Instructions Portable Proportional Braking System Installation Instructions Part number 9400 Time Tested Time Proven ROADMASTER, Inc. 6110 NE 127th Ave. Vancouver, WA 98682 800-669-9690 Fax 360-735-9300 roadmasterinc.com

More information

ATTENTION: THIS IS NOT A RELEASED DOCUMENT. Labor Flat Rates DRAFT. Aeromaster and Truck Body

ATTENTION: THIS IS NOT A RELEASED DOCUMENT. Labor Flat Rates DRAFT. Aeromaster and Truck Body Contents ATTENTION: THIS IS NOT A RELEASED DOCUMENT. Service Guide Labor Flat Rates Aeromaster and Truck Body Flat Rates and Labor Operation Codes...3 Door...3 Side Sliding...3 Swing...4 Bulkhead...4 Rear

More information