TABLE OF CONTENTS INTRODUCTION 3. INSTALLATION PROCEDURES Air Conditioner Location 4. A/C Ducting Installation 5
|
|
- Clare Bridges
- 6 years ago
- Views:
Transcription
1
2 TABLE OF CONTENTS SECTION PAGE INTRODUCTION 3 INSTALLATION PROCEDURES Air Conditioner Location 4 Air Conditioner Mounting 4 A/C Ducting Installation 5 Power Kit Installation (Batteries). 5 Separator... 6 OPERATION MANUAL GENERAL DESCRIPTION OF INSTALLATION 9 PARTS LIST TOOLS LIST.. 12 INSTALLATION INSTRUCTIONS ELECTRICAL SYSTEM BATTERY BOX MOUNTING NITE SYSTEM CHECK LIST SEPARATOR CHECKLIST
3 INTRODUCTION BERGSTROM S NITE AIR CONDITIONING SYSTEM The NITE system is a compact electrical 3,000 BTU air conditioning system. This unit is quality engineered to provide a dependable means of air conditioning to the cab area without idling the engine. The NITE unit is completely self-contained and runs on 12 volts using the greatest deep cycle battery technology. This no-idle air conditioning system is designed to provide cool air to the cab interior in order to maintain passenger comfort. In order to conserve battery power and life, this system is not designed to instantly cool down a hot cab that has been sitting under an extreme solar load. If these kind of conditions occur, it is recommended to start the trucks engine and let the OEM a/c system help cool the cab for a few minutes. Then the truck can be shut off and the NITE system will continue to keep the cab cool and the driver comfortable. The NITE system operates independently off of it s own deep cycle batteries and is completely isolated away from the trucks starting batteries. The A/C is operated by its own 3-speed control. It cycles through 3 blower settings (low, medium, and high). On high speed, the system will run for 1 hour and then automatically switch the blower to medium speed in order to conserve battery power. The control has a battery indicator light so the driver always knows how much charge he has. A green light equals full charge, a yellow light equals half charge, and a red light means the batteries need to be recharged. The NITE batteries will be fully recharged after about 4-6 hours of driving. 3
4 NITE INSTALLATION PROCEDURE GENERAL COMMENTS AIR CONDITIONER LOCATION Depending on the type of vehicle, the best location for mounting the a/c unit will vary. Generally, the units are mounted underneath the matress in the sleeper; either in the center compartment or one of the side storage compartments. However, the unit can be mounted anywhere else inside the cab of the truck provided you adhere to the following conditions: Unit must be mounted flat on the floor of the vehicle. Do not mount the unit outside of the vehicle to prevent weather damage and lack of performance. The condenser air inlet and exhaust must be diverted out underneath the truck with openings in the floor. For ease of installation, make sure the condenser openings do not interfere with any support structures underneath the floor. Also consider the following when selecting a location: - Ducting - Electrical routing - Condenser inlet/ exhaust openings - Recirculation air AIR CONDITIONER MOUNTING A mounting plate and the hardware are provided with the NITE kit. Choose the air conditioner unit location Use the provided template to mark and cut out the two rectangles needed for the condenser openings. The mounting plate gets mounted to the floor, then the unit attaches to the mounting plate. For ease of installation, make sure the condenser openings do not interfere with any support structures underneath the floor. 4
5 A/C DUCTING INSTALLATION Ducting kits are application specific. Depending on the application, some kits are designed to tie into the OEM ducting and others are universal and supplied with a 4 flex hose. In routing and installing the systems ducting, the following criteria must be observed: Route the ducting with smooth bends and transitions. Avoid crushing the duct work with tools and etc. Be sure all of the treated air is routed above the mattress as close to the driver s body as possible. Kits can be supplied with either a Tower Duct or a T-Duct. POWER KIT INSTALLATION (BATTERIES, ISOLATOR) BATTERIES The NITE system is powered by two 6 volt batteries running in series to give you 12 volts. The batteries are a sealed, deep cycle, dry cell battery. They need to be mounted inside the provided battery box. The battery box is generally mounted on the frame rail of the truck. However, if there is no room on the frame rail, the batteries may be mounted inside on of the trucks side storage compartments. Since the batteries are sealed and dry celled, there is no hazard in doing this. Things to observe when mounting the battery box: Find a general location on the frame rail, usually just behind one of the fuel tanks. Be sure to have at least 4 inches of free space on both sides of the battery box to allow room for wiring and the rubber latches. Try to locate existing holes or bolts in the frame rail to capture. It is difficult to drill a ½ hole into the frame, so this will help ease the installation. 5
6 SEPARATOR Depending on the truck isolator the system can require a separator in place of an isolator. It has the same purpose as the isolator but acts differently. The separator is mounted in the sleeper, under the mattress It is electrically connected between the truck batteries and the NITE batteries 6
7 NITE AIR CONDITIONING AND HEATING SYSTEM OPERATION MANUAL CONTROLS NO-IDLE AIR CONDITIONING NO-IDLE HEATING OFF LOW MEDIUM MAX OFF ON TEMPERATURE CONTROL BATTERY INDICATOR VENTILATOR OPERATION NOTES After 1 hour of operation, the MAX A/C setting will automatically switch to the MEDIUM A/C setting. This feature is done to provide optimum system energy efficiency. With the upgraded 4 battery system the max A/C setting remains constant. The heater ventilation mode is to be used for continuous operation of the heater at a pre-selected temperature setting. The temperature control knob has no function while in ventilation mode. The Green battery light indicates normal operation. When the battery light changes to Yellow, it indicates the batteries are at about half charge. The light will change to Red and the system will shut down automatically when the engine needs to be started in order to recharge the batteries. 7
8 NITE AIR CONDITIONING AND HEATING SYSTEM OPERATION NOTES For optimal comfort Bergstrom recommends to close the curtain between the cab and the sleeper when using the NITE A/C and heating system. The NITE A/C system is designed to maintain a comfortable temperature inside the cab without the engine running. The A/C unit will not pull down a hot cab that has been sitting in the sun without the factory A/C running. To assist the NITE system in cooling down the cab, start the engine and run the factory A/C system for a few minutes. This will help cool the cab to a respectable temperature. Once the cab is pulled down, the NITE system will maintain a comfortable temperature. The system must be turned off every time the system is not in use or the batteries May not charge properly. After use of the system be sure to turn the control knob to the off position, even if the unit is not running. BATTERIES & FUSES The system must be turned off every time the system is not in use or the batteries may not charge properly. After using the system turn the control back off, even if the unit is not running. The NITE A/C and heating system uses its own batteries. A battery isolator or separator keeps the starting batteries from being drawn down. The NITE A/C and heating system switches off automatically when batteries charge level is low. The A/C fuses (2) are located next to the NITE A/C unit, under the bunk. The parking heater fuse (1) is located inside the battery box. SERVICE The NITE A/C unit is not serviceable. If problems are encountered please contact the NITE line at
9 GENERAL DESCRIPTION OF THE INSTALLATION The unit is mounted under the bed, in the central storage compartment. A ducting device is mounted on the back wall (and slides behind the bed pan) to distribute the cold air to the bunk area. 9
10 PARTS LIST BERGSTROM# DESCRIPTION QTY INSTALLATION INSTRUCTIONS OPERATION MANUAL ASSEMBLY, NO-IDLE UNIT (HORIZONTAL OUTLET) BATTERY, 6 VOLT DEEP CYCLE ASSY, MOUNTING PLATE KIT, "T" DUCT (TALL) ASSY, "T" DUCT TALL SCREW, FLAT HEAD KIT, INSTALLATION TEMPLATE, UNIT LOCATE SCREEN, DUCT MOUNT ANGLE, DUCT COLLAR DUCT, "T" INLET TRANSITION DUCT, UNIT OUTLET 90 4X DUCT, INLET 90 4X4 1 B HOSE, DEFROST 4" I.D. 3 FT CONTROL, A/C WIRE HARNESS SCREW, TRUSS HD #10 SELF TAP SCREW, M6 X 16MM TORX HD SCREW, SELF DRILL S-CLIP, TINNERMAN 8 B CLAMP, HOSE 4.12 I.D WASHER, 1/4" FLAT 8 10
11 KIT, NITE POWER ASSEMBLY, BATTERY BOX WELDMENT, BATT. HOLD DOWN ASS'Y, WIRE BATT. CABLE 5300MM BLACK ASS'Y, WIRE BATT. CABLE 5000MM RED ASS'Y, WIRE BATT. CABLE 225MM HARNESS, WIRE NO-IDLE POWER SEPARATOR 100 AMPS FUSE, MAXI 50 AMP. 1 B RING TERMINAL, 5/16 2 B WIRE LOOM,.413 I.D. X FT. B STRAP, CABLE TIE BOLT, 5/16-18 X 11" NUT, 5/15-18 LOCK 1 B WASHER, 5/16 FLAT 2 B BOLT, 1/2-13 X 1 1/2 4 B LOCKNUT, 1/ WASHER, 1/2 FLAT WIRE, 16 GA BLACK BLADE TERMINAL RING TERMINAL, 5/16 16 GA 1 11
12 REQUIRED TOOLS 1) DRILL BITS (1/4, ½, ) 2) HOLE SAWS (4 1/8 OR 4 1/4) 3) ELECTRIC/AIR DRILL 4) SCREWDRIVERS (FLAT HEAD & PHILLIPS HEAD) 5) IMPACT GUN 6) AIRSAW/ JIGSAW (CUTTING SHEETMETAL) 7) TORX HEAD (T30) 8) METRIC WRENCHES 9) ENGLISH WRENCHES 10) ¼, 3/8 DRIVE RATCHETS 11) ENGLISH SOCKET SET 12) METRIC SOCKET SET 13) WIRE CUTTERS 14) TERMINAL CRIMPERS 15) WIRE STRIPPERS 16) RAZOR KNIFE 17) ELECTRICAL TAPE 12
13 INSTALLATION INSTRUCTIONS THE NITE UNIT IS GOING TO BE MOUNTED UNDER THE LOWER BUNK, IN THE CENTRAL COMPARTMENT. PLACE THE TEMPLATE (454787) ON THE FLOOR, IN THE CENTRAL STORAGE COMPARTMENT, AS SHOWN ON THE FOLLOWING DRAWING: BACK WALL PASSENGER SIDE DRIVER SIDE 2 5 TRUCK FORWARD MARK THE (2) RECTANGLE OPENINGS ON THE FLOOR. REMOVE THE TEMPLATE. USE A ½ DRILL BIT TO DRILL OUT THE OPPOSING CORNERS ON EACH OF THE TWO RECTANGLES USE A JIGSAW OR AN AIRSAW TO CUT OUT THE TWO RECTANGLES. THESE TWO OPENINGS WILL ACT AS THE AIR INLET AND EXHAUST FOR THE A/C UNIT CONDENSER. 13
14 ONCE THE OPENINGS ARE CUT, PLACE THE ALUMINUM MOUNTING PLATE (870143) INTO POSITION AS SHOWN USE THE PROVIDED 1 TEK SCREWS TO MOUNT THE ALUMINUM PLATE SECURELY TO THE FLOOR. NOW THE A/C UNIT CAN BE PREPARED FOR INSTALLATION THE 90 DEGREE PLASTIC ELBOW (530719) NEEDS TO BE ATTACHED TO THE OUTLET SIDE OF THE UNIT. FIRST MOUNT THE SQUARE METAL BRACKET (454651) TO THE SIDE OF THE UNIT AS SHOWN. USE THE EXISTING 5 TORX SCREWS LOCATED IN THIS SAME LOCATION. 14
15 MOUNT THE PLASTIC ELBOW TO THE METAL BRACKET AS SHOWN. THE ELBOW WILL NEED TO FACING THE BACK WALL OF THE TRUCK WHEN THE A/C UNIT IS MOUNTED IN POSITION. MAKE SURE ALL FOUR METAL TABS OF THE BRACKET SEAT INSIDE THE WALLS OF THE PLASTIC ELBOW. SECURE USING THE PROVIDED TEK SCREWS OR BLACK SHEET METAL SCREWS. PLACE THE UNIT IN THE ALUMINUM MOUNTING PLATE, WITH THE PLASTIC ELBOW FACING THE BACKWALL. SECURE THE UNIT TO THE MOUNTING PLATE, USING (4) TORX HEAD SCREWS, ONE IN EACH OF THE FOUR CORNERS OF THE PLATE, AT BOTH ENDS BACK WALL TRUCK FORWARD 15
16 PREPARE THE T SHAPE DUCT THAT WILL BE MOUNTED ON THE BACK WALL. 16
17 TAKE THE DUCT ASSEMBLY (870158) AND MOUNT THE T DUCT INLET (530718) TO THE BOTTOM OF THE T-DUCT, USING THE PROVIDED SCREWS AS SHOWN: (3) SCREWS ACROSS THE FRONT AND (2) SCREWS IN THE BACK. INSERT THE PLASTIC ELBOW (530719) INSIDE THE SQUARE OPENING OF THE T INLET, AND SCREW IT INTO PLACE AS SHOWN BACK FRONT 17
18 THE BED PAN SUPPORT BRACKET NOW NEEDS TO BE CUT, SO THAT THE T DUCT ASSEMBLY CAN SLIDE BEHIND THE BED, AND CAN BE CONNECTED TO THE UNIT UNDER THE BED. THE OPENING THAT NEEDS TO BE CUT IN THE BRACKET MUST BE 13 WIDE AND 2 DEEP. 18
19 THE FOLLOWING DRAWING WHOWS WERE THE OPENING NEEDS TO BE MADE IN THE SLEEPER. VIEW FROM TOP 2 (FROM THE SUPPORT BRACKET DRIVER SIDE EDGE) BACK WALL PASSENGE SIDE DRIVER SIDE 2 5 TRUCK FORWARD 19
20 THE FOLLOWING DRAWING SHOWS A CUT VIEW OF THE BED PAN SUPPORT BRACKET, FROM THE PASSENGER SIDE, AND THE CUT THAT NEEDS TO BE MADE (USE AND AIRSAW TO CUT THIS OPENING) PIANO HINGE BACK WALL ALUMINUM SUPPORT BRACKET PLASTIC BED PAN 2 ONCE THE OPENING IS DONE PUT THE T DUCT ASSEMBLY + STEALTH + ELBOW IN PLACE ON THE BACKWALL, AND MARK ON THE PLASTIC BACK OF THE STORAGE COMPARTMENT WHAT NEEDS TO BE CUT, SO THAT THE DUCT SEATS ALONGSIDE THE BACL WALL. REMOVE THE DUCT ASSEMBLY, AND, USING AN AIR SAW, CUT THIS OPENING BACKWALL CUT IN PLASTIC BACK WALL FOR DUCT CLEARANCE 20
21 REMOVE THE (4) TOP RECTANGLE LOUVERS OF THE T-DUCT. PUT THE DUCT ASSEMBLY IN PLACE AND ATTACH (1) SELF DRILL SCREW + (1) WASHER THROUGH THE DUCT AND THE BACK WALL TRIM, IN EACH OF THE (4) LOUVER OPENINGS. PLACE THE LOUVERS BACK IN PLACE, AND USE THE PROVIDED SCREWS TO SECURE THEM ON THE DUCT. ON THE BOTTOM OF THE DUCT SCREW THE SCREEN (454556) AS SHOWN ON THE FOLLOWING PICTURE, IN ORDER TO SECURE THE DUCT BOTTOM TO THE PLASTIC BACK WALL. PERFORATED SCREN 21
22 CONNECT THE 4 FLEXIBLE HOSE (B310000) TO THE DUCT BOTTOM ELBOW AND THE UNIT PLASTIC ELBOW, AND SECURE IT WITH THE (2) PROVIDED CLAMP (B290303) FIND A LOCATION FOR THE CONTROL ASSEMBLY (880031). IT CAN BE MOUNTED ON THE SLEEPER CONTROL PANEL, OR A WALL CABINET. WHEN THE CONTROL LOCATION IS CHOSEN CUT A 2.5 HOLE, USING A HOLE SAW. ROUTE THE CONTROL HARNESS (660679) FROM THE UNIT TO THE CONTROL LOCATION. PLUG THE BLACK PLUG OF THE CONTROL HARNESS TO THE BOWER SWITCH OF THE CONTROL ASSEMBLY. SLIDE THE BACK OF THE CONTROL AND THE HARNESS THROUGH THE HOLE AND SECURE IT, USING THE (4) PROVIDED SHEET METAL SCREWS. 22
23 NEXT TO THE UNIT PLUG THE CONTROL HARNESS (660724) TO THE UNIT WHITE PLUG 23
24 ELECTRICAL SYSTEM INSTALLATION 1. Now begin making the proper electrical connections. First connect white plug of the control harness into the orange plug on the side of the A/C unit as shown below. 2. Now drill a 1-3/8 (1.375 ) hole in the floor next to the A/C unit. This hole will be used for routing the power wires out to the battery supply. 3. Run the black and red wired power harness through the hole in the floor. Connect the black plug of the harness into the black plug on the side of the A/C unit. INSTALLATION NOTE: IF YOU HAVE THE HEATER OPTION, NOW IS A GOOD TIME TO REVIEW THE HEATER INSTRUCTIONS AND BEGIN THE HEATER INSTALL. THIS WILL SAVE YOU SOME TIME BEFORE STARTING TO INSTALL THE POWER SYTEM OUTSIDE OF THE CAB. 24
25 ELECTRICAL SYSTEM BATTERY SEPARATOR The battery separator ties into the truck starting batteries. The separator puts charging priority to the starting batteries and then charges the Nite batteries. The NITE batteries begin charging after the starting batteries have reached 13.2 volts. 25
26 SEPARATOR WIRING SCHEMATIC w/ 2 BATTERIES The wiring instructions are written on the separator too 4 GA Use the bottom terminal for ground The 2 other terminals are not used 4 GA SEPARATOR 16 GA NITE UNIT + HEATER ALTERNATOR STARTER TRUCK BATTERY NITE BATTERIES 26
27 SEPARATOR WIRING SCHEMATIC w/ 4 BATTERIES The wiring instructions are written on the separator too Use the bottom terminal for ground The 2 other terminals are not used 4 GA 4 GA SEPARATOR 16 GA NITE UNIT + HEATER ALTERNATOR STARTER NITE BATTERIES TRUCK BATTERY NITE BATTERIES 27
28 BATTERY BOX INSTALLATION INSTRUCTIONS 1) THE BATTERY BOX IS DESIGNED AS A UNIVERSAL MOUNTING TO BE BOLTED ON EITHER THE DRIVER S SIDE OR PASSENGER SIDE FRAME RAIL. 2) USE THE 10 MOUNTING HOLES LOCATED ON THE BACK OF THE BATTERY BOX IN ORDER TO CAPTURE 4 EXISTING HOLES OR BOLTS ON THE FRAME RAIL. 3) IF NO EMPTY HOLES OR BOLTS ARE EXCESSIBLE FOR MOUNTING THE BOX, DRILL (4) HALF INCH HOLES INTO THE FRAME RAIL USING THE FOUR OUTSIDE MOUNTING HOLES OF THE BATTERY BOX. CAUTION: WHEN DRILLING INTO THE FRAME RAIL, BE SURE TO STAY AT LEAST 40MM AWAY FROM THE TOP AND BOTTOM EDGE OF THE FRAME. NOTE: MOUNT THE BATTERY BOX ON THE FRAME RAIL CLOSE TO THE LOCATION OF THE FUEL TANK TO INSURE THE BATTERY CABLES WILL BE LONG ENOUGH. 4) USE THE PROVIDED ½ BOLTS AND LOCKNUTS TO BOLT THE BATTERY BOX TO THE FRAMERAIL USING AN IMPACT GUN. 5) PLACE THE TWO BATTERIES SIDE BY SIDE INSIDE THE BATTERY BOX. NOTE: BE SURE TO POSITION THE BATTERIES POWER AND GROUND OPPOSITE OF ONE ANOTHER. ONE BATTERIES GROUND WILL BE NEXT TO THE OTHER BATTERIES POSITIVE. 6) PLACE THE H -BRACKET ON TOP OF THE BATTERIES. NOW USE THE PROVIDED 11 BOLT AND RUN THROUGH THE TOP OF THE H-BRACKET BETWEEEN THE TWO BATTERIES. INSERT THE BOLT DOWN THROUGH THE HOLE IN THE BOTTOM ON THE BATTERY BOX AND FASTEN IS SECURELY WITH THE LOCKNUT. 7) NOW MAKE THE PROPER BATTERY CONNECTIONS AS SHOWN ON PAGE
29 NITE SYSTEM CHECK LIST 1. NITE unit basics The control of the NITE unit has 3 positions: Low, Medium and High. For each control position the compressor speed and the evaporator blower are set differently. The following table shows how the compressor and the blower are set for each control position: Control position Capacity setting Blower speed Compressor speed 1 Low Low Low 2 Medium High Low 3 High High High Note 1: there is no change of airflow when switching from position 2 to position 3. Only the compressor speed changes. Note 2: in addition to the evaporator blower and to the compressor there is another electrical device that makes the NITE system work: the condenser fan. As well as the compressor and the evaporator blower, the condenser fan is located inside the NITE unit. It sucks air from underneath the sleeper floor and blows it to the outside as well. Whatever the position of the control (low, medium or high), the condenser fan speed remains the same. Note 3: When the control is set on HIGH (position 3) the system will automatically switched to the MEDIUM setting after an hour of operation. This permits to increase the NITE system running time without affecting the performances. When this automatic switch is performed the compressor speed changes and the airflow (blower speed) remains the same. No such change occurs for an upgraded 4 battery system. 2. Checking of the different NITE unit components The following table explains out to check that the different components of the NITE unit are running correctly when the NITE unit is ON. The next paragraph will explain how to evaluate that the different components are working fine. Component Function How to check it is working Blows cold air inside the sleeper area, through the ducting The system is a 100% Blower (evaporator) recirculation system; the air intakes (2) are located on top and side of the NITE unit Switch the NITE control to position 1; you must feel air coming out of the duct louvers Then switch the NITE control to position 2; you must feel an increase of the airflow coming out of the duct louvers Note: make sure nothing blocks the air intake opening (recirculation) on the NITE unit 29
30 Component Function How to check it is working Fan (condenser) Takes ambient air Goes under the sleeper and check under the sleeper floor that air is going out the condenser and rejects it from the air outlet when the NITE unit is floor too running (inlet and outlet are located The air goes through next to each other) the condenser coil to On the inlet you must feel the air cool it down going into the NITE unit On the outlet you must feel the air Compressor Compresses and runs the refrigerant through the NITE unit refrigerant loop going out of the NITE unit. The best way to check that the compressor is running is to feel the compressor speed changes when the control is switched from position 2 to position 3 (the compressor speed goes from low to high). Set the control to position MEDIUM and lift up the bed, so that you can hear the NITE unit vibration & sound change. Wait 1 minute. Then set the control to position HIGH: you must notice a change in the vibration & sound of the NITE unit when the compressor speed changes. A better verification is to touch the unit (or have someone touching it) in order to feel the vibration changes. 3. NITE unit electrical and temperature checking The following instructions list how to check that the NITE unit is working properly NITE unit electrical power check the NITE unit voltage: close to the unit, on the power supply cables (red and black cables), there is a black connector on which the voltage can be read. When the NITE batteries are fully charged and when the control position is on HIGH, you must read between 12 and 12.5 volts check the NITE unit current: when the NITE unit control is on HIGH position and using a clamp-on inductive ammeter, measure the current on the NITE unit power supply RED cable. You must read between 27 and 35 Amps Louvers temperature check the louvers temperature: when the NITE unit control in on HIGH position, when the sleeper temperature is between 75 and 80 F and when the outside temperature is between 90 and 95 F, measure the temperature directly at one of the duct louvers. You must read between 55 and 62 F. 30
31 3.2. Condenser outlet temperature as described earlier in this document the NITE unit pulls air from outside, under the sleeper floor to cool down the condenser coil, then the air is rejected to the outside from the sleeper floor too. When the NITE unit is running in HIGH position, go under the sleeper and locate the condenser air outlet (rectangle opening with a screen). The temperature at the condenser outlet must be 10 to 20 F higher than the outside temperature 31
32 ELECTRICAL CHECK LIST NITE SYSTEM WITH SEPARATOR 1. Make sure you don t have any loose electrical connections 2. Check that the installation is done according to the electrical diagram 2.1. Make sure the 16 ga ground wire is connected to the bottom blade terminal of the separator on one end, and to any good ground on the other end (truck batteries ground, or NITE batteries ground, or frame(last choice)) 2.2. In case of a 2-battery system, make sure the 2 NITE batteries are connected in series with a jumper. In case of a 4-battery system, make sure the batteries are connected in series and parallel. Each battery is a 6 V one, the NITE system runs in 12 VDC Make sure the ground of the NITE batteries is connected to a good ground (truck batteries ground, or frame (last choice), or alternator ground) 2.4. Make sure the NITE unit power cables are connected to the correct terminals of the NITE batteries. The red cable goes to the positive terminal; the black cable goes to the ground. 3. Voltage checking engine OFF 3.1. Check that the voltage on the truck batteries is the same as the voltage on the separator (main batteries side). When you check the voltage on the separator, use the ground terminal on the separator. Both voltages should be the same Check that the voltage on the NITE batteries is the same as the voltage on the separator (aux batteries side). When you check the voltage on the separator, use the ground terminal on the separator. Both voltages should be the same (approx. 12 V) 32
33 4. Voltage checking engine ON The separator charges the batteries as follow: - when the engine is ON the alternator is going to start to charge the truck batteries first, until the truck batteries voltage reaches 13.2 V. During this period, the separator is open and the NITE batteries are not charged - when the truck batteries reaches 13.2 V, the separator closes and the NITE batteries are being charged 4.1. Engine ON, check the voltage of the truck batteries. It should be higher than the voltage when engine is OFF (> 13 V). 4.2 In order to check that the separator works properly, wait for the truck batteries voltage to reach at least 13.2 V. Increase the engine rpm if necessary. When the separator closes to start charging the NITE batteries, you can hear an audible click of the separator. Check the NITE batteries voltage. It should be higher than the voltage when the engine is OFF (approx. the voltage of the truck batteries) In order to double check that the separator allows the NITE batteries to be charged you can measure the Amps going to the NITE batteries, using a clampon type inductive ammeter, on the 4 ga cable that connects the separator to the NITE batteries positive terminal. It should be > 0 Amp. 33
TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..
585457 1 TABLE OF CONTENTS SECTION PAGE INTRODUCTION.. 3 INSTALLATION PROCEDURES Air Conditioner Location...4 Air Conditioner Mounting 4 A/C Ducting Installation...5 Power Kit Installation (Batteries)...5
More informationModel 377, 379, 386, 388, Sleeper no window
Installation Manual Model 377, 379, 386, 388, 389 63 Sleeper no window 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 NITE Plus Installation Procedures 1-2 Table
More informationInstallation Manual Blackhawk Road Rockford, IL
Installation Manual 2390 Blackhawk Road Rockford, IL 61072 815-874-7821 www.bergstrominc.com Table of Contents Introduction Before You Start Parts List Tools Required Installation Procedures Electrical
More informationInstallation Manual #
FINAL 10/06/08 Installation Manual #1000067001 Cascadia Under Bunk Mounting Bergstrom, Inc. 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 Table of Contents Introduction
More informationInstallation Manual #
Final 10/01/08 Installation Manual # 585416 T600, T800 and W900 Bergstrom, Inc. 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 Table of Contents Introduction Before
More informationInstallation Manual #
FINAL 10/06/08 Installation Manual #1000067014 Bergstrom, Inc. 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 Table of Contents Introduction Before You Start 3 4
More informationSetting the World s Performance Standards
Setting the World s Performance Standards 743 East Iona Road, Idaho Falls, ID 83401, (208) 529-0244 Fax (208) 529-9000 Forced Air Hot Air Elimination Kit (Bed Fan Kit) For 800 RZR-4 P/N 67-165 Kit Contents:
More informationInstallation Manual. Underbunk Columbia and Century models Blackhawk Road P.O. Box 6007 Rockford, IL
Installation Manual Underbunk Columbia and Century models 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 Table of Contents Introduction Before You Start Parts List
More informationInstallation Manual. Cascadia. For Phoenix Gen 4 units built after 6/26/2017
Installation Manual Cascadia For Phoenix Gen 4 units built after 6/26/2017 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 Table of Contents Introduction Before You
More informationPERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969-70 MUSTANG CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect
More informationClassic Sleeper including T600, T660, T800 and W900
Installation Manual Classic Sleeper including T600, T660, T800 and W900 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 Table Installation of Contents Procedures
More informationKenworth T680 without factory installed heater
Installation Manual Kenworth T680 without factory installed heater 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 Table of Contents Introduction Before You Start
More informationInstallation Manual CLASSIC SLEEPER NO WORKSTATION Blackhawk Road P.O. Box 6007 Rockford, IL
Installation Manual CLASSIC SLEEPER NO WORKSTATION 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 Table of Contents Introduction Before You Start Parts List Tools
More informationInstallation Manual. 9000i Passenger side install Blackhawk Road P.O. Box 6007 Rockford, IL
Installation Manual 9000i Passenger side install 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 Table of Contents Introduction Before You Start Parts List Tools
More informationKenworth T680 without factory installed heater
Installation Manual Kenworth T680 without factory installed heater For Phoenix Gen 4 units built after 6/26/2017 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 8-31-17
More informationAir Conditioner for M915 A0/A1 Truck
RD-2-4530-0 Air Conditioner for M915 A0/A1 Truck INSTALLATION INSTRUCTIONS Install refrigerant compressor per instructions provided with compressor mount kit. CAUTION: Edges of sheet metal can be sharp!
More informationInstallation Manual. CH, CL, CXU, CXN and Vision Blackhawk Road P.O. Box 6007 Rockford, IL
Installation Manual CH, CL, CXU, CXN and Vision 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 www.nitesystem.com 1-866-204-8570 Table of Contents Introduction Before You Start Parts List Tools Required
More informationPERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO CONTROL & OPERATING
More informationProcharger Stage II Intercooled Supercharger System (11-14 GT)
Procharger Stage II Intercooled Supercharger System (11-14 GT) Installation Time: Approximately one day. Installed on 2012 Mustang GT 5.0/Manual Required Tools 3/8 Socket Set (Standard and Metric) 1/2
More informationJeep Wrangler TJ. Complete Air Conditioning System. Slide Control Head. Installation instructions
WWW.JEEPAIR.COM 1996-1998 Jeep Wrangler TJ Complete Air Conditioning System Slide Control Head Installation instructions Kit Information After 1994 every vehicle was designed for R134a refrigerant. The
More informationTechnical Information and Diagnostic Guide
Technical Information and Diagnostic Guide This guide will assist you in becoming more familiar with the working components of the NITE System and the proper steps and procedures to completely diagnose
More information& 76 CHEVROLET NOVA HEATER ONLY
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic hi l PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1969-74 & 76 CHEVROLET NOVA HEATER ONLY CONTROL & OPERATING INSTRUCTIONS The controls on
More information1963 GEN IV SUREFIT VINTAGE AIR CONDITIONING INSTALLATION
by Randy Irwin 1963 GEN IV SUREFIT VINTAGE AIR CONDITIONING INSTALLATION Randy Irwin - Technical Writer Randy has been involved in the Chevy parts business for over 30 years. He is a wizard at creating,
More informationWPS-104 Heater Installation Instructions For 500EFI, 700 XP, & Crew Applications
WPS-104 Heater Installation Instructions For 500EFI, 700 XP, & Crew Applications ORDER OF INSTALLATION FOR A COMPLETE ENCLOSURE OF A RANGERWARE WPS (Weather Protection System) IS AS FOLLOWS: 1. Heater
More informationPERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD FAIRLANE & CROWN VICTORIA
PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1955-56 FORD FAIRLANE & CROWN VICTORIA CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect Fit system, offer complete comfort capabilities in virtually
More informationJeep Wrangler 4.0 Liter TJ Jeep Wrangler 2.5 Liter TJ Installation instructions
TM www.jeepair.com 1999 Jeep Wrangler 4.0 Liter TJ 1999-2001 Jeep Wrangler 2.5 Liter TJ Installation instructions Kit Information After 1994 every vehicle was designed for R134a refrigerant. The Jeep kit
More informationSECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.
Technical Information and Diagnostic Guide for SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator. This guide will assist you in becoming more
More informationHeater/Defroster Installation Instructions
1301 39 th Street NW, Suite 2 * Fargo, ND 58102 * Toll Free 866.764.0616 * Fax 701.446.0103 * www.gemcar.com Service Instructions Heater/Defroster Installation Instructions Models: All 2005 - Current Part
More informationFACTORY AIR CONVERSION HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle FACTORY AIR CONVERSION HEAT/ COOL/ DEFROST 1970-72 CHEVROLET CHEVELLE CONTROL & OPERATING INSTRUCTIONS The controls on your
More informationPRODUCT SAFETY NOTICE
PRODUCT SAFETY NOTICE Congratulations. This vehicle has been equipped with a Firestone air suspension system. This suspension will enhance the vehicle s handling when loaded, however, the vehicle s performance
More informationInstallation Instructions for Lingenfelter GM 2500 Suburban & Yukon XL Auxiliary Fan System (with AC clutch controlled fan output)
Installation Instructions for Lingenfelter 2007-2013 GM 2500 Suburban & Yukon XL Auxiliary Fan System (with AC clutch controlled fan output) PN L300080607 Revision - 1.1 Lingenfelter Performance Engineering
More informationNITE SSI Service Parts List NITE Tech Support Line #
NITE SSI Service Parts List Changes in Red X = Obsolete P/N S = Supersedes in place of original P/N R = Replaced by P/N U = Use up and obsolete = Current/Original P/N Page 1 of 19 Product Description NITE
More informationInstallation Instruction for '84-'89 Nissan 300ZX High Performance Intercooler System (Part No )
Installation Instruction for '84-'89 Nissan 300ZX High Performance Intercooler System (Part No. 2-124) Page ii DCB (06/14/02 12:19 AM) Version 1.0 Page iii Table of Contents 1. TOOLS REQUIRED...1 2. INSTALLATION
More informationThis harness kit includes: Installing the Hybrid ReVolt Universal grid charger in an Insight
Installing the Hybrid ReVolt Universal grid charger in an Insight This harness kit includes: Insight harness (2000 to 2006) (a) 4 #6 mounting screws for bulkhead (c) 2 sheet metal screws for fan board
More information6945 (12v) 6944 (24V) installation instructions
6945 (12v) 6944 (24V) installation instructions included: tools needed: Cordless drill Breezeeasy Fan Mounting brackets 1/4 Drill Bit 10mm Socket Hardware Pack 10mm Wrench Fuse Assembly Wire Stripper Crimper
More informationITEM QTY CHECK PART NUMBER DESCRIPTION
PART #21128 2010 Camaro Cold Air Induction Stage II PACKING LIST Before installation, use this check list to make sure all necessary parts have been included. ITEM QTY CHECK PART NUMBER DESCRIPTION 1.
More informationPRODUCT: Install Instructions, MV-1 C/O Std, With Aux Fan RELEASE DATE: 2/28/14 REVISION DATE: 9/30/2014 PART NUMBER: Rev C
Parts List (1) 01 000 027 Switch, 4 Position Blower (1) 04 000 007 Hose, 1/2 ID Drain, 6 (1) 01 000 087 Harn, Resistor (1) 04 000 078 Tube, Convo 1/2 x 24 (2) 01 000 136 Relay, 40 Amp (1) 04 000 015 Hose,
More informationThird Generation NITE Phoenix
Technical Information and Diagnostic Guide for Third Generation NITE Phoenix Use this guide with unit serial number prefix beginning with BYC, CAI built after 2-10-2012 and CCA, CDJ, CIA units after 6/25/2012
More informationINSTALLATION INSTRUCTIONS FUEL SURGE TANK KIT
INSTALLATION INSTRUCTIONS FUEL SURGE TANK KIT BMW E46 3-Series, Excl Convertible Document: 19-0056 Support: info@radiumauto.com Relieve fuel pressure in vehicle before beginingthe installation. Disconnect
More informationINSTALLATION & OWNER S MANUAL
INSTALLATION & OWNER S MANUAL CAB INSTALLATION INSTRUCTIONS JOHN DEERE 3000 SERIES (4200/4300/4400) (4210/4310/4410) & (3120/3320/3520/3720) HARD SIDED CAB ENCLOSURE (p/n 1JD3520AS) SOFT SIDED CAB ENCLOSURE
More informationFord Racing 4.6L 3V Crate Engine Control Pack
Ford Racing 4.6L 3V Crate Engine Control Pack Installation Time: 3-6 hours on a Foxbody Mustang Tools Required: Basic English and Metric Socket and Wrench Set Flat and Phillips Screwdrivers Torx bits Hammer
More informationInstallation Instruction for '84-'89 Nissan 300ZX High Performance Intercooler System (Part No )
Installation Instruction for '84-'89 Nissan 300ZX High Performance Intercooler System (Part No. 2-124) Routing of the Intercooler Pipe It is necessary to follow the exact sequence of the installation
More informationJeep Wrangler TJ 4.0 LITER Installation instructions
www.jeepair.com 2000-2001 Jeep Wrangler TJ 4.0 LITER Installation instructions Important information about your system, and warranty DO NOT ADD ANY OIL TO ANY PART OF THE SYSTEM. DO NOT USE THE SIGHT GLASS
More informationInstallation Instructions for Lingenfelter GM 2500 Suburban & Yukon XL Auxiliary Fan System (with ECM controlled fan output)
Installation Instructions for Lingenfelter 2007-2013 GM 2500 Suburban & Yukon XL Auxiliary Fan System (with ECM controlled fan output) PN L300090607 Revision - 1.1 Lingenfelter Performance Engineering
More informationLGT-312L E-Z-Go TXT Light Bar Bumper Kit Installation Instructions
LGT-312L E-Z-Go TXT 2014+ Light Bar Bumper Kit Installation Instructions Caution: Please read through the instructions carefully. Before starting this project, remove the system s positive and negative
More informationAdjustable Light Kits E-Z-Go TXT All Models Installation Instructions
Adjustable Light Kits E-Z-Go TXT All Models 1996-2013 Installation Instructions Caution: Please read through the instructions carefully. Before starting this project, remove the system s positive and negative
More informationeapu Installation Manual
eapu Installation Manual #61033 REV A 1 Topic Table of Contents Page Number System & Installation Overview 3-5 Pallet Contents 6 Mounting the Frame Rail Unit 7-12 Battery Installation 13-14 Frame Brackets
More informationWiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.
1 10/2014 REV 7 !!Attention!! Before performing diagnostics: Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents. Check for Fault Codes using the
More informationJODALE PERRY. Parts List & Mounting Instructions. Jacobsen HR9016 JDP BUILT FOR LIFE
JODALE PERRY Parts List & Mounting Instructions Jacobsen HR9016 JDP BUILT FOR LIFE Jacobsen HR9016 Mounting Instructions Standard Parts 1 - LH Rear Mounting Bracket 1 - RH Rear Mounting Bracket 1 - Front
More informationPRODUCT SAFETY NOTICE DEALER/INSTALLER NOTICE
PRODUCT SAFETY NOTICE Congratulations. This vehicle has been equipped with a Firestone air suspension system. This suspension will enhance the vehicle s handling when loaded, however, the vehicle s performance
More information2015 Mustang Lightbar (All Models) CDC#
2015 Mustang Lightbar (All Models) CDC# 1511-7000-01 Components: 1 CDC Lightbar Note: READ instructions before starting installation!!! CDC Part# Driver side bracket 0511-6001-05 Passenger side bracket
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Part# 22-7810 Add On Kit for Your ADS System Contents: Complete Install Kit for Your ARB CKMTA12V Compressor For the most up-to-date instructions please visit www.updownair.com
More informationTechnical Support (707)
Installation Instructions CONSOLE MEGASHIFTER Fits: 1982-1992 Camaro & Firebird w/automatic Transmission *except 1988-1992 Firebird Formula Model Catalog # 80692 WORK SAFELY! For maximum safety, perform
More informationSCION xd INTERIOR LIGHTING UPGRADE Preparation
Preparation Part Number: PTS21-52085 Light Guide Kit Contents Item # Quantity Reqd. Description 1 1 Controller Board, 4 color programmed w/ Bracket 2 1 RGB, LED Engine wire harness 3 2 14mm Light Rod,
More informationL/6.7L DODGE CUMMINS
10/19/2012 2005-08 5.9/6.7 Dodge Cummins FlowMAX Lift Pump Kit # 1050310B - 1-2005-09 5.9L/6.7L DODGE CUMMINS BD FLOWMax V2 LIFT PUMP KIT Installation Instructions P/N # 1050310B PLEASE READ ALL INSTRUCTIONS
More information½ DODGE CUMMINS
7 April 2009 2003-04½ Dodge Cummins FlowMAX Lift Pump Kit # 1050305-1 - 2003-04½ DODGE CUMMINS BD FlowMax LIFT PUMP KIT Installation Instructions P/N# 1050305 PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE
More informationINSTALLATION & OWNER S MANUAL
Rev. B, p. 1 of 25 INSTALLATION & OWNER S MANUAL POLARIS RANGER RCS (for models XP or HD) (for model years 2009-) cab without doors kit (p/n 1POLRCWD) cab with doors kit (p/n 1POLRC) doors only kit (p/n
More informationLGT-306L / LB Club Car Precedent LED Light Bar Bumper Kit Installation Instructions
LGT-306L / LB Club Car Precedent LED Light Bar Bumper Kit Installation Instructions Caution: Please read through the instructions carefully. Before starting this project, remove the system s positive and
More informationDODGE CUMMINS 24V ISB
4 September 2013 1998-2002 Dodge Cummins FlowMAX Lift Pump Kit # 1050301C - 1-1998-02 DODGE CUMMINS 24V ISB FLOWMAX LIFT PUMP KIT I n s t a l l a t i o n I n s t r u c t i o n s Part# 1050301C PLEASE READ
More informationINSTALLATION INSTRUCTIONS AIR/OIL SEPARATOR KIT
INSTALLATION INSTRUCTIONS AIR/OIL SEPARATOR KIT 2015+ SUBARU WRX (LHD ONLY) Document: 19-0136 Support: info@radiumauto.com This document covers the installation of the Radium brake master cylinder brace
More informationINSTALLATION INSTRUCTIONS
Rear Vision System Tailgate Emblem Camera Mirror Display 2009-Current Ford F-150 and 2010-Current Super Duty (Kit part number 1008-9527) Kit Contents: Mirror Tailgate Emblem Mount with Camera Interior
More informationINSTALLATION INSTRUCTIONS JEEP 2011-UP JK SECURITY FULL CONSOLE #274
INSTALLATION INSTRUCTIONS JEEP 2011-UP JK SECURITY FULL CONSOLE #274 PARTS CHECKLIST Tuffy Console #9 Left Front Mounting Bracket #10 Right Front Mounting Bracket #11 Electronics mounting bracket #12 Divider
More informationPFadvantage JD 3300/4400/6600/7700; 4420
Ag Leader Technology Combine Installation JD 33//66/77; 2 Note: Indented items indicate parts included Quantity by Model in an assembly listed above Early Late Part Name/Description Part Number 3 3 6 6
More informationREV 1 THE GRIP IDLE MANAGEMENT SYSTEM
INSTALLATION MANUAL This manual will provide the installer with the necessary information to install the GRIP system and all of its optional equipment on most vehicle configurations. This book also contains
More informationFactory Five Racing, Inc. 818 Kit Assembly manual revision 1J update
Factory Five Racing, Inc. 818 Kit Assembly manual revision 1J update Turbo coolant overflow tank...1 Shifter handle...4 Install...4 Door skin...7 Door Liner... 10 Side mirrors... 14 Door handles and pulls...
More informationINSTALLATION INSTRUCTIONS C-VS-2000-DUR-1 20 VEHICLE SPECIFIC CONSOLE for 2018 Dodge Durango with Standard Shifter
INSTALLATION INSTRUCTIONS C-VS-2000-DUR-1 20 VEHICLE SPECIFIC CONSOLE for 2018 Dodge Durango with Standard Shifter TOOLS REQUIRED: Phillips Screw Driver T-20 Torx bit Standard Socket set 9/64 Allen wrench
More information½ DODGE CUMMINS
19 October 2012 2003-04½ Dodge Cummins FlowMAX Lift Pump Kit # 1050305B - 1-2003-04½ DODGE CUMMINS BD FlowMax LIFT PUMP KIT Installation Instructions P/N# 1050305B PLEASE READ ALL INSTRUCTIONS CAREFULLY
More informationINSTALLATION & OWNER S MANUAL
INSTALLATION & OWNER S MANUAL CAB INSTALLATION INSTRUCTIONS MASSEY FERGUSON TGX SERIES SOFT SIDED CAB ENCLOSURE (p/n MFTGXSS) This Curtis Cab is designed and manufactured for use only as reasonable weather
More informationPart # Mopar LX Level 1 Air Suspension System
Part # 13040199 05-14 Mopar LX Level 1 Air Suspension System Front Components: 1 1304409 Front RQ ShockWave Kit for Stock Lower Arms Rear Components: 1 13044099 Rear CoolRide Kit 1 13040709 RQ Series Rear
More informationR-4122 Sleeper Heater/ Air Conditioner Unit. R-2550 Heater/Air Conditioner Unit RED DOT UNITS HEATER-A/C RESCUE VEHICLES
R-2550 Heater/Air Conditioner Unit RESCUE VEHICLES The R-2550 is specifically designed for ambulances and other lighter-duty vehicles with large interior spaces to heat and cool quickly. R-2550 SPECIFICATIONS
More informationThis harness kit includes: Civic harness (2003 to 2005) Installing the Hybrid ReVolt Universal grid charger in a First Gen Civic ( )
Installing the Hybrid ReVolt Universal grid charger in a First Gen Civic (2003-2005) This harness kit includes: Civic harness (2003 to 2005) (a) 1 HV warning label (c) 1 charger connector cover (e) 4 #6
More informationDepress each tab as you pull the bezel off. The bezels are tight. L.H. shown.
2013-2014 Ford Mustang V6 & Boss 302 Lower Valance Fog Light Kit Parts List: Quantity: Tool List: Fog light & bulb with bracket 2 Flat head & Phillips screwdriver Black bezels 2 Ratchet & Socket set OR
More informationSolarSheat Wall Installation Manual
SolarSheat Wall Installation Manual Version 1.5 April 23, 2013 Copyright 2013 Your Solar Home, All Rights Reserved SolarSheat products must be installed in accordance to all local building, plumbing, electrical,
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory HITCH Application 2009 CR-V Publications No. AII 40373 Issue Date AUG 2008 PARTS LIST Plain washer, 12 mm Trailer Hitch Kit P/N 08L92-SWA-100 Trailer hitch 6 Spring
More informationINSTALLATION INSTRUCTIONS
COLD AIR INTAKE INSTALLATION INSTRUCTIONS PART NUMBER D760-0390C APPLICATION: 1999-2003 E39 M5 PARTS LIST 1 Left Aluminum Intake Tube 1 Air Pump Bracket (A) 1 Right Aluminum Intake Tube 1 Air Pump Bracket
More informationINSTALLATION INSTRUCTIONS
Rear Vision System Tailgate Handle Camera Mirror Display 2004-2014 Ford F-150 and 2008-2015 Ford Super Duty (Kit part numbers 9002-9521) Kit Contents: Mirror Tailgate Handle with camera and harness Interior
More information½ DODGE CUMMINS
15 June 2016 #1050305D 2003-2004½ Dodge Cummins FlowMAX Lift Pump Kit (I-00169) - 1-2003-04½ DODGE CUMMINS BD FLOWMAX LIFT PUMP KIT Installation Instructions P/N# 1050305D PLEASE READ ALL INSTRUCTIONS
More informationR-8230 Underdash Heater/Air Conditioner Unit
INTERNATIONAL R-8230 Underdash Heater/Air Conditioner Unit NAVISTAR INTERNATIONAL S, 4000, 7000, and 8000 SERIES TRUCKS, 1983 1994 The R-8230 exceeds the performance of the original system and has styling
More informationL/6.7L DODGE CUMMINS
6/15/2016 #1050310D 2005-09 5.9/6.7 Dodge Cummins FlowMAX Lift Pump Kit (I-00170) - 1-2005-09 5.9L/6.7L DODGE CUMMINS BD FLOWMAX LIFT PUMP KIT Installation Instructions P/N # 1050310D PLEASE READ ALL INSTRUCTIONS
More informationSubaru Front Mount Intercooler Kit STI Subaru Front Mount Intercooler Kit STI
Subaru Front Mount Intercooler Kit STI 2008-2014 715500 Subaru Front Mount Intercooler Kit STI 2008-2014 Congratulations on your purchase of the Subaru Front Mount Intercooler Kit STI 2008-2014. The following
More informationWPS-104 Heater. Installation Instructions
WPS-104 Heater Installation Instructions For 2007 vehicles see page 15 WPS 104 HEATER SYSTEM INSTALLATION INSTRUCTIONS If this is a complete installation of top, windshield and heater system, for ease
More informationTechnical Information and Diagnostic Guide RestStar Use this guide with 5700XE RestStar Unit. Western Star 5700XE.
Western Star 5700XE RestStar 4 10-2017 1 Technical Information and Diagnostic Guide RestStar Use this guide with 5700XE RestStar Unit 2390 Blackhawk Road P.O. Box 6007 Rockford, IL 61125 nitesystem.com
More informationBD Venom Dual Fuel F O R D 6. 7 L P O W E R S T R O K E Installation Instructions
U 21 March 2017 (1050470) Venom Dual Fuel Kit (I-00390) 1 DOWNLOAD ENHANCED INSTALL MANUALS AT dieselperformance.com BD Venom Dual Fuel 2 0 1 1-2 0 1 6 F O R D 6. 7 L P O W E R S T R O K E Installation
More informationScion xa SATELLITE RADIO TUNER Preparation
Preparation Part Number: PTS31-00051 Kit Contents Item # Quantity Reqd. Description 1 1 Antenna, Interior 2 1 Antenna Tape Pad 3 1 Wire Harness 4 1 Bracket, Floor 5 3 Hardware Bags 6 3 Templates 7 1 SIRIUS
More informationBD Venom Dual Fuel F O R D 6. 7 L P O W E R S T R O K E Installation Instructions
U 30 January 2017 (1050470) Venom Dual Fuel Kit (I-00390) 1 DOWNLOAD ENHANCED INSTALL MANUALS AT dieselperformance.com BD Venom Dual Fuel 2 0 1 1-2 0 1 4 F O R D 6. 7 L P O W E R S T R O K E Installation
More informationJeep Wrangler TJ 4.0 LITER Installation instructions
www.jeepair.com 2002-2004 Jeep Wrangler TJ 4.0 LITER Installation instructions Kit Information These directions are for 2002-2006 model Jeep Wranglers. After 1994 every vehicle was designed for R134a refrigerant.
More informationGPS AutoSteer System Installation Manual
GPS AutoSteer System Installation Manual Supported Vehicles New Holland Combines CR 9040 CX 9040 CR 9050 CX 9050 CR 9060 CX 9060 CR 9070 CX 9070 CR 9080 CX 9080 IntelliSteer Ready PN: 602-0231-01-A LEGAL
More informationSolarSheat Wall Installation Manual
SolarSheat Wall Installation Manual Version 3.2 December 15, 2015 Copyright 2015 Your Solar Home, All Rights Reserved SolarSheat products must be installed in accordance to all local building, plumbing,
More information= Experienced
I N S T A L L A T I O N G U I D E APPLICATION LENGTH MODEL YR PART # Ford F-250 / F-350 / F-450 Regular Cab * (48 ) 2002-2003, 2008-2012 75134-01A Ford F-250 / F-350 / F-450 Super Cab * (60 ) 2002-2003,
More informationInstallation Instructions
Installation Instructions Jeep JK 2-Door (2011 Present) Mounting Bracket and Air Line System Kit for ARB On-Board Twin Air Compressor (CKMTA12) Made in the USA Kit Contents: 1 Flat Bracket 1 Formed Bracket
More information3-5 Hours Professional installation recommended
I N S T A L L A T I O N G U I D E APPLICATION AMP Part # Chevrolet Silverado 2500/3500 / GMC Sierra 2500/3500 - Ext. Cab * 2007-201 75126-01A Chevrolet Silverado 2500/3500 / GMC Sierra 2500/3500 - Crew
More informationHEAT/ COOL/ DEFROST CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT FACTORY AIR CONVERSION HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS The controls
More informationRam 1500 Crew Cab A Ram 2500/3500 Crew Cab A
I N S T A L L A T I O N G U I D E APPLICATION AMP Part # Ram 1500 Crew Cab 2013-2015 77138-01A Ram 2500/3500 Crew Cab 2013-2015 77138-01A Note:The application works only on the Crew Cab model Vehicles.
More information08-18 STI Flex Fuel Bluetooth Mk2 Kit Install Instructions For Cobb Tuning Access Port
For Cobb Tuning Access Port Delicious Tuning 1948 Don Lee Place Suite #7 Escondido, CA 92029 408-480-0995 Rough Draft BJP Rev: 2.0 Date: 2/1/17 FFBT parts: (1) Ethanol Content Analyzer Module (1) Ethanol
More informationINSTALLATION INSTRUCTIONS
Rear Vision System Mirror Display Dodge Ram Kit Contents: Instruction Sheets Template Chassis Harness Endgate Handle with Camera Wire Ties (Qty: 17) Bottle of ZTech Plug for Non-Locking Endgates (Optional)
More informationINSTALLATION & OWNER S MANUAL
INDUSTRIES, LLC. INSTALLATION & OWNER S MANUAL CAB INSTALLATION INSTRUCTIONS KUBOTA GRAND L 40 SERIES HARD SIDED CAB ENCLOSURE (p/n 1KGL4AS) This Curtis Cab is designed and manufactured for use only as
More informationFRONT MOUNT INTERCOOLER GOLF / JETTA IV 1.8T PART # & P INSTALATION INSTRUCTIONS
FRONT MOUNT INTERCOOLER GOLF / JETTA IV 1.8T PART # 48.10.90 & 48.10.90P INSTALATION INSTRUCTIONS PART LIST: 1 INTERCOOLER CORE 1 U-BENT TUBE 1 L-SHAPED TUBE 1 INTERCOOLER INLET TUBE 4 M6 NYLOC NUT 3 M6
More informationStand Alone Fog Lights Installation Instructions
Tools Required: 1. Trim Removal tool or protected flat screwdriver 2. #2 Phillips Screwdriver 3. 10mm socket 4. 10mm wrench 5. 8mm or 5/16 socket 6. Adjustable Pliers 7. Electrical Tape WARNING!!! Disconnect
More information1. Disconnect the battery. This is important! This will prevent air bag deployment.
PARTS PACKING LIST Evaporator assembly Drain tube Plastic air plug Hardware package 11040 3601 W. Clarendon Phoenix, Arizona 85019 (602) 233-0090 800-648-4475 www.ackits.com 2003-4 Jeep Wrangler EVAPORATOR
More informationElectronic Refrigerator Diagnostics
Electronic Refrigerator Diagnostics IMPORTANT SAFETY NOTICE The information in this presentation is intended for use by individuals possessing adequate backgrounds of electrical, electronic, & mechanical
More information