Rheem-Ruud Commercial

Size: px
Start display at page:

Download "Rheem-Ruud Commercial"

Transcription

1 POCKET GUIDE Rheem-Ruud Commercial water heaters Tanktype Gas & Electric Hot Water Supply Heaters Indirect Storage Tanks Technical Service HEATER3 U.S. Customer Service U.S. Fax Canada Customer Service Canada Fax Website...rheem.com In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice. Rheem Water Heating and Heating & Cooling Products 101 Bell Road Montgomery, AL Rheem manufactures residential and commercial heating & cooling and water heating products. Rheem Canada Ltd./Ltée 125 Edgeware Road, Unit 1 Brampton, Ontario, L6Y 0P5 Not all models are available in Canada. Printed in U.S.A. 03/10 WP Form No. RR105-2 Rev. 27 Commercial water heaters from Rheem-Ruud

2 COMMERCIAL GAS WATER HEATERS SPIDERfire Models GHE (A) thru GHE (A) AdvantagePlus Models HE thru HE Universal Models G50-98 thru G (A) Universal Low NOx Models GN thru GN (A) Xtreme Models GX90-550(A) thru GX90-715(A) VentMaster Power Direct Vent Models GP & GP (A) Induced Draft GD (A) thru GD (A) Medium Duty Models G60-50 thru G PowerVent GPV75-75E Power Venter Kits COMMERCIAL HOT WATER SUPPLY HEATERS With Pump GBBP136 thru GBCP Without Pump GBB136 thru GBC TABLE OF CONTENTS COMMERCIAL ELECTRIC WATER HEATERS Large Volume EVRO, EVS and EHSO Models Heavy Duty ES50, ES85, ES120, E50(A), E85(A) and E120(A) PowerPack Heavy Duty E12A, E20A, E30A and E40A Eclipse Booster E Light Duty Models ELD30 thru ELD Light Duty Models ELDS30 thru ELDS Point-of-Use EGSP2 thru EGSP INDIRECT WATER HEATERS COMMERCIAL STORAGE TANkS ST80(A), ST120(A) and ST175(A) Large Volume Storage Tanks CertiSpec 3.2 on Internet Download A.O. SMITH Gas Tank Type BTR & BTH (Cyclone) Gas Hot Water Supply Heaters BC, HW & DW Storage Tank Systems TJ, TJV Electric Light/Heavy Duty & Boosters DEL, DEN, DRE, DVE, CMC, SU AMERICAN Gas Tank Type PVCG32, CG32, DCG32, PVDCG32, DCG Electric Light/Heavy Duty LDCE, ITCE,STCE, AITCE, ASTCE Storage Tank Systems CST, ACST BRADFORD WHITE Gas Tank Type Gas Hot Water Supply Heaters L-I-T Storage Tank Systems M-3-ST Electric Light/Heavy Duty Booster M-II-SF-CF, LI COMPETITOR CROSS REFERENCE INDEX Dimensions reflect models built prior to 1/20/04. LOCHINVAR Gas Tank Type CNR, CNA Gas Hot Water Supply Heaters CPN, RWN, CWN Storage Tank Systems RJS, RJA Electric Light/Heavy Duty & Boosters ETX, ETW, ESX, ETX, SB, HS, HC STATE Gas Tank Type SBT, SBF Electric Light /Heavy Duty CPE, SB Storage Tank Systems PV... 71

3 SPIDERfire Sealed Combustion Gas-Fired 130, ,000 BTU/HR. 2 SPIDERfire Features: INTAKE (On Selected Models) (With Optional Kit) Maximum thermal efficiency of 95% dramatically reduces operating costs No chimney required; power or direct vent using plastic pipe Low NOx emissions. Meets SCAQMD Rule Corrosion resistant, high efficiency 3-pass heat exchanger Self-diagnostic LCD electronic control Direct spark ignition 185 F maximum temperature setting Zero clearance to all combustible surfaces Full flow drain valve Front and back water connectioins Factory installed AGA/ASME rated T&P relief valve A HOT OUT FRONT COLD IN FRONT D T&P C H F G HAND HOLE CLEANOUT DRAIN VALVE EXHAUST AIR INTAKE TEMP SENSOR TOP VIEW HOT OUT REAR COLD IN REAR T&P DRAIN VALVE GAS INLET EXHAUST E LEFT SIDE B FRONT RIGHT SIDE REAR RECOVERy CAPACITIES MODEL INPuT (BTu/HR) THERMAL TEMP. RISE GPH NuMBER NAT. & LP EFFICIENCy units 40 F 100 F 140 F GHE (A) 130,000 95% GPH GHE (A) 160,000 95% GPH GHE (A) 199,000 95% GPH GHE (A) 250,000 93% GPH GHE (A) 300,000 93% GPH GHE (A) 350,000 92% GPH *Weights listed are for non-asme. Add 35 lbs. for ASME models. 130, ,000 BTU models are certified to be installed with 2" venting. All models require a 120V power source. See use and care manual for venting details. Overall width is 27-5/16" due to exhaust cover. DIMENSIONAL INFORMATION All dimensions shown in inches WATER CONNECTS APPROX. A B C D E F G H VENT INLET OuTLET SHIP. WT. (LB)* 78-3/4 26-1/ /4 73-3/4 73-5/8 72-7/ /16 2, 3, 4 2" NPT 2" NPT /4 26-1/ /4 73-3/4 73-5/8 72-7/ /16 2, 3, 4 2" NPT 2" NPT /4 26-1/ /4 73-3/4 73-5/8 72-7/ /16 2, 3, 4 2" NPT 2" NPT /4 26-1/ /4 73-3/4 73-5/8 72-7/ /16 3, 4 2" NPT 2" NPT /4 26-1/ /4 73-3/4 73-5/8 72-7/ /16 3, 4 2" NPT 2" NPT /4 26-1/ /4 73-3/4 73-5/8 72-7/ /16 3, 4 2" NPT 2" NPT 825 0" CLEARANCE TO COMBUSTIBLES MODELS WITH INPUTS OF 130,000 BTU THRU 199,000 BTU ARE CERTIFIED TO VENT WITH 2" SCHEDULE 40 PVC, CPVC OR ABS PIPE (FOR CANADIAN INSTALLATIONS, PLEASE USE ULC-S636 PVC AND CPVC PIPE.) 3

4 4 AdvantagePlus Sealed Combustion Gas 100, ,000 BTU/HR. AdvantagePlus Features: 316L stainless steel tank construction (requires no anode rods). No chimney required; direct vent using plastic pipe. Thermal efficiency of 95% dramatically reduces operating costs. 85 equivalent feet of vent length. Low NOx emissions. Meets SCAQMD Rule High impact plastic jacket eliminates dents. 2 of non-cfc, polyurethane foam insulation. Less than 1/2 degree per hour heat loss (R17). Corrosion resistant, high efficiency 90/10 cupronickel heat exchanger. Self-diagnostic electronic control with digital readout for water temperature, set point and differential. Removable front cover allows easy access to equipment (24" service clearance recommended). Temperature range from 70 F to 160 F (maximum temperature setting of 180 F available on HE and HE booster models only). Zero clearance to all combustible surfaces. Factory installed AGA/ASME rated T&P relief valve. Booster installation kit provided with HE and HE booster models. (All models require 120V power source.) A D E B Hot Out Cold In C Gas Inlet Electrical Connection 3.75 F Condensate Connection RECOVERY CAPACITIES MODEL CAP. INPUT (BTU/HR.) THERMAL TEMPERATURE RISE DEGREES F GALLONS PER HOUR NUMBER GALS. NAT. & LP EFFICIENCY HE55-100* ,000 95% N/A N/A HE55-130* ,000 95% N/A N/A HE80-130* ,000 95% N/A N/A HE * ,000 95% N/A N/A HE ,000 95% HE ,000 95% N/A N/A HE ,000 95% N/A N/A HE ,000 95% HE ,000 95% N/A N/A HE ,000 95% N/A N/A The recovery rate is based on recovery efficiencies obtained in a UL certified laboratory. These models have been tested according to ANSI Z test procedures and exceed the thermal efficiency and standby loss requirements of ASHRAE (part of the Federally mandated Energy Policy Act - EPACT). These models also exceed the energy efficiency codes of all states including the California Energy Commission (CEC). All models are North Carolina Code compliant. DIMENSIONAL INFORMATION (All dimensions shown in inches) MODEL WATER CONNECTIONS APPROX. SHIPPING CLEARANCE TO NUMBER A B C D E F VENT INLET OUTLET WEIGHT (LBS.) COMBUSTIBLES HE55-100* / /4 2* lbs HE55-130* / /4 2* lbs HE80-130* / /4 2* 1-1/2 1-1/2 235 lbs HE * /4 6-3/4 28-7/8 2* 1-1/2 1-1/2 405 lbs HE / / lbs HE / / /2 1-1/2 235 lbs HE /4 6-3/4 28-7/ /2 1-1/2 405 lbs HE / / lbs HE / / /2 1-1/2 235 lbs HE /4 6-3/4 28-7/ /2 1-1/2 405 lbs *The models with inputs of 100,000 kbtu and 130,000 kbtu are certified to vent with 2" Schedule 40 PVC, CPVC or ABS pipe. (For Canadian models, vent with 2" ULC-S636 PVC or CPVC pipe) Use HEC prefix for Canadian models. The HE and HE Booster models are the only models equipped with a 180 F thermostat. Models with 180 F thermostats come standard with the Booster Installation kit which includes all necessary components for an approved installation. BOOSTER INSTALLATION kit INCLUDES: Nibco Tee 1" x 1" x 1/2" (2 pieces) Female Adapter 1" (2 pieces) Dial Thermometer (2 pieces) Expansion Tank 4-1/2 gallon Grundfos 3 Speed Pump with Check Valve Nibco 1.2" x 12" Fitting Air Chamber Vacuum Relief Valve Pressure Gauge PSI Nibco Tee 712R 1" x 1" x 3/4" (2 pieces) Nibco Tee 714RR 1" x 1/2" x 1" Nibco Tee 1" x 1/2" x 1" Copper Reducing Coupling Pressure Reducing Valve Nibco Male Adapter 1" 5

5 6 Universal Heavy Duty Gas 98, ,000 BTU/HR. (On Selected Models) (With Optional Leg Kit) Universal Features: Small jacket diameters Short floor-to-vent heights Multiple water connections System Sentinel LED diagnostic system Standard Features: 3 year limited tank warranty Patented multiflue design Low profile automatic flue damper Spark-to-pilot ignition system Full port, full flow brass drain valve Factory installed AGA/ASME rated T&P relief valve Handhole cleanout Stainless steel burners 180 max operating temperature LED diagnostics on all damper assemblies for easier service Certified for a 150 PSI maximum working pressure (160 PSI for ASME models) Manual reset high limit (ASME models) Low NOx models available OUTLET TOP OUTLET REAR SIDE SYSTEM SENTINEL G 7" (178mm) H E OUTLET FRONT SIDE C INLET FRONT SIDE INLET REAR SIDE T&P INLET TOP D F B A RECOVERY CAPACITIES MODEL GAL. INPUT BTU/HR. THERMAL TEMP. RISE - GPH NUMBER CAP. NATURAL & L.P. EFFICIENCY G ,000 80% G ,000 80% G ,000 80% G ,000 80% G ,900 80% G ,900 80% G ,900 80% G (A) ,900 80% G72-250(A) ,000 80% G (A) ,000 80% G (A) ,000 80% G72-300(A) ,000 80% G85-300(A) ,000 80% G (A) ,000 80% G65-360(A) ,000 80% G65-400(A) ,900 80% G85-400(A) ,900 80% G (A) ,900 80% DIMENSIONAL INFORMATION (All dimensions shown in inches) A B C D E F G H WATER CONNECTIONS APPROX. SHIPPING CLEARANCES TO TOP FRONT REAR WEIGHT (LBS.) COMBUSTIBLES IN/OUT SIDE SIDE STANDARD ASME SIDE REAR TOP 62-3/4 57-1/8 22-1/2 22-5/ /2 1/ /2 1-1/2 270 N/A 2" 2" 12" 65-1/ / / /2 1-1/2 1-1/2 480 N/A 2" 2" 12" 68-13/ / /8 3/ /2 1-1/2 1-1/2 490 N/A 2" 2" 12" 68-13/ / /8 3/ /2 1-1/2 1-1/2 540 N/A 2" 2" 12" 49-1/4 43-3/8 26-1/ /8 3/ /2 1-1/2 1-1/2 405 N/A 2" 2" 12" 68-13/ / /8 3/ /2 1-1/2 1-1/2 540 N/A 2" 2" 12" 76-5/ / /4 30-5/ /8 3/ /2 1-1/2 1-1/2 600 N/A 2" 2" 12" 73-1/ /8 30-1/4 23-1/ /2 3/ / " 4" 12" 71-1/ /2 26-1/ /8 3/ /2 1-1/2 1-1/ " 6" 12" 73-1/4 66-1/8 30-1/4 23-1/ /2 3/ / " 4" 12" 73-7/8 66-1/8 30-1/4 23-1/ /2 3/ / " 4" 12" /2 26-1/ /8 3/ /2 1-1/2 1-1/ " 6" 12" 78-7/ / /4 30-5/ /8 3/ /2 1-1/2 1-1/ " 6" 12" /2 30-1/4 32-1/ /4 3/ / " 4" 12" 70-11/ /2 26-1/ /8 3/4 N/A N/A 1-1/2 1-1/ " 6" 12" 70-11/ /2 26-1/ /8 3/4 N/A N/A 1-1/2 1-1/ " 6" 12" 78-13/ / /4 30-5/ /8 3/ /2 1-1/2 1-1/ " 6" 12" /2 30-1/4 32-1/ /4 1* / " 4" 12" Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. Thermal Efficiency in accordance with ANSI Z labeling requirements. (A) Indicates Available ASME Model. *3/4" for L.P. Models. Increase Height 3-5/8" for NSF Models. All Models Require a 120V Power Source. These models have been tested according to ANSI test procedures, and exceed the thermal efficiency and standby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). All models are North Carolina Code compliant. 7

6 8 Universal Heavy Duty Gas Low NOx 125, ,000 BTU/HR. (On Selected Models) Universal Features: Small jacket diameters Short floor-to-vent heights Multiple water connections System Sentinel LED diagnostic system Standard Features: 3 year limited tank warranty Patented multiflue design Low profile automatic flue damper Spark-to-pilot ignition system Full port, full flow brass drain valve Factory installed AGA/ASME rated T&P relief valve Handhole cleanout 180 max operating temperature Certified for a 150 PSI maximum working pressure (160 PSI for ASME models) Manual reset high limit (ASME models) Low NOx Burner The Power Assist enclosed burner design incorporates stainless steel multi-port burner tubes for long term Low NOx compliant performance. A sight glass allows for burner observation and the entire assembly is easily removable. A blower guard is provided against post-installation damage. The entire design is highly resistant to the effects of negative air pressures common to modern commercial buildings. OUTLET TOP OUTLET REAR SIDE SYSTEM SENTINEL G 7" (178mm) H E OUTLET FRONT SIDE C INLET FRONT SIDE INLET REAR SIDE T&P INLET TOP D F B A DIMENSIONS (Inches) WATER CONNECTIONS APPROXIMATE MODEL TOP FRONT REAR SHIPPING WEIGHT NUMBER A B C D E F G H IN/OUT SIDE SIDE STD. ASME GN / / / /2 1-1/2 1-1/2 480 lbs. N/A GN / / /8 3/ /2 1-1/2 1-1/2 490 lbs. N/A GN /4 43-3/8 26-1/ /8 3/ /2 1-1/2 1-1/2 405 lbs. N/A GN / / /8 3/ /2 1-1/2 1-1/2 540 lbs. N/A GN / / /4 30-5/ /8 3/ /2 1-1/2 1-1/2 600 lbs. N/A GN (A) 73-1/ /8 30-1/4 23-1/ /2 3/ / lbs. 835 lbs. GN72-250(A) 71-1/ /2 26-1/ /8 3/ /2 1-1/2 1-1/2 590 lbs. 630 lbs. GN (A) 73-1/4 66-1/8 30-1/4 23-1/ /2 3/ / lbs. 835 lbs. GN (A) 73-7/8 66-1/8 30-1/4 23-1/ /2 3/ / lbs. 845 lbs. GN65-360(A) 70-11/ /2 26-1/ /8 3/4 N/A N/A 1-1/2 1-1/2 640 lbs. 680 lbs. GN (A) /2 30-1/4 32-1/ / / lbs. 810 lbs. All Models Require a 120V /1.5 Amp Power Source. (A) Suffix Indicates ASME Tank Construction Available. 9

7 Xtreme High-Input Gas 550, ,000 BTU/HR. 10 C US LISTED Xtreme Features: Small jacket diameters Short floor-to-vent heights Multiple water connections System Sentinel LED diagnostic system Standard Features: 3 year limited tank warranty Patented multiflue design Low profile automatic flue damper Specialized burner assembly Spark-to-pilot ignition system Full port, full flow brass drain valve Factory installed AGA/ASME rated T&P relief valve Handhole cleanout Round premix stainless steel burners Manual reset high limit Certified for a 150 PSI maximum working pressure (160 PSI for ASME models) Low NOx models: GX90-550(A) GX90-640(A) RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises. MODEL INPUT BTU/HR. THERMAL NUMBER NATURAL & L.P. EFFICIENCY 40 F 50 F 60 F 70 F 80 F 90 F 100 F 110 F 120 F 130 F 140 F GX90-550(A) 550,000 NAT 80% GX90-640(A) 640,000 NAT 80% GX90-715(A) 715,000 NAT 80% GX90-500(A) LP 500,000 LP 80% GX90-600(A) LP 600,000 LP 80% GX90-680(A) LP 680,000 LP 80% Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. These models have been tested according to ANSI Z test procedures, and exceed the thermal efficiency and standby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states. (A) indicates available ASME model. DIMENSIONAL INFORMATION (All dimensions shown in inches) WATER CONNECTIONS APPROXIMATE MODEL FRONT REAR SHIPPING WEIGHT NUMBER A B C D E F G SIDE SIDE STD. ASME GX90-550(A) GX90-640(A) GX90-715(A) GX90-500(A) LP GX90-600(A) LP GX90-680(A) LP All Models Require a 120V Power Source. (A) Suffix Indicates ASME Tank Construction Available. 11

8 VentMaster Power Direct Vent Gas 150, ,000 BTU/HR. 12 Standard Features: Non-condensing design Integral automatic blower Patented multi-flue tank design Spark-to-pilot ignition system System Sentinel LED diagnostic system Full port, full flow brass drain valve No masonry or metal vent chimney required Installs with 3" or 4" schedule 40 PVC pipe Vents up to 50 feet C E B F D A RECOVERY CAPACITIES (80% thermal efficiency) MODEL INPUT GPH NUMBER BTU/HR. 40 F 50 F 60 F 70 F 80 F 90 F 100 F 110 F 120 F 130 F 140 F GP , GP , GP (A) 250, CLEARANCE TO COMBUSTIBLES (inches) MODEL NUMBER SIDE REAR TOP GP " 6" 18" GP GP (A) 51mm 153mm 459mm FIRST TIME DELIVERY (Includes useable storage and recovery for indicated times.) TEMP. RISE AT 100 F IN GALLONS Minutes MODEL TANk CAP. INPUT to Rec. NUMBER GALLONS BTU/HR. Minutes Minutes Minutes Minutes Minutes Minutes Minutes Contents GP , GP , GP (A) , DIMENSIONS (Inches) WATER CONNECTIONS APPROXIMATE MODEL FRONT REAR NUMBER A B C D E F G IN/OUT SIDE SHIPPING WEIGHT GP /4 68-1/4 30-1/4 24-3/ / lbs. GP /4 68-1/4 30-1/4 24-3/ / lbs. GP (A) 81-3/4 68-1/4 30-1/4 24-3/ / lbs. Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. These models have been tested according to ANSI Z test procedures, and exceed the thermal efficiency and standby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states. (A) indicates available ASME model. 13

9 Induced Draft Gas 250, ,000 BTU/HR. 14 (On Selected Models) (With Optional Leg Kit) Universal Features: Small jacket diameters Short floor-to-vent heights Multiple water connections System Sentinel LED diagnostic system Standard Features: 3 year limited tank warranty Patented multiflue design Factory installed draft inducer provides an induced draft allowing higher BTU's to be vented through a 6" vent 6" Category I appliance allows for easy upgrade or retrofit of existing applications Spark-to-pilot ignition system Full port, full flow brass drain valve OUTLET TOP OUTLET REAR SIDE SYSTEM SENTINEL G 7" (178mm) H E OUTLET FRONT SIDE C INLET FRONT SIDE INLET REAR SIDE T&P INLET TOP D F B A RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises. MODEL INPUT BTU/HR. THERMAL NUMBER NATURAL & L.P. EFFICIENCY UNITS 40 F 50 F 60 F 70 F 80 F 90 F 100 F 110 F 120 F 130 F 140 F GD (A) 250,000 80% GPH GD (A) 270,000 80% GPH GD (A) 310,000 80% GPH GD (A) 360,000 80% GPH Recovery ratings are based on thermal efficiencies obtained in a CSA certified laboratory. These models have been tested according to ANSI Z test procedures, and exceed the thermal efficiency and standby loss requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states. (A) indicates available ASME model. DIMENSIONAL INFORMATION All Dimensions Shown in English. WATER CONNECTIONS APPROXIMATE MODEL TOP FRONT REAR SHIPPING WEIGHT NUMBER UNITS A B C D E F G H IN/OUT SIDE SIDE STD. ASME GD (A) inches 73-1/2 66-3/4 30-1/4 23-1/ /2 3/ / lbs. 835 lbs. GD (A) inches 73-1/2 66-3/4 30-1/4 23-1/ /2 3/ / lbs. 835 lbs. GD (A) inches 73-1/2 66-3/4 30-1/4 23-1/ /2 3/ / lbs. 835 lbs. GD (A) inches 73-1/2 66-3/4 30-1/4 23-1/ /2 3/ / lbs. 835 lbs. All models require a 120V /3 amp power source. (A) suffix indicates ASME tank construction available. 15

10 Medium-Duty Gas 45,000 80,000 BTU/HR. 16 (with optional leg kit) Standard Features: Small jacket diameters Short floor-to-vent heights 3 year limited tank warranty Rigid foam insulation Heavy duty anode rod Factory installed AGA/ASME rated T&P relief valve Brass drain valve Gas control system Certified for a 150 PSI maximum working pressure Low NOx models available N Models A B D 1/2" F E C G 3/4" N.P.T. RELIEF VALVE OPENING SIDE TAPS G50-65, G60-50 & G75-75 SIDE TAPS ON 50 & 75 GAL. MODELS ONLY G50-65 & G60-50 WATER CONNECTIONSARE 3/4" NPT G75-75 WATER CONNECTIONS ARE 1" NPT A B D F E HOT & COLD C 1/2" GAS CONNECTION G /4" T & P 2" WATER CONNECTIONS ARE 1" NPT G RECOVERY CAPACITIES MODEL CAP. INPUT GAS TEMPERATURE RISE DEGREES F GALLONS PER HOUR NUMBER GALS. BTU/HR. TYPE G60-50N * 60 Natural 50, G60-50LP* 60 LP 45, G50-65N * 48 Natural 65, G50-65LP* 48 LP 48, G75-75N-2 * 75 Natural 75, G75-75LP* 75 LP 65, G Natural 80, G100-80N 100 Natural 76, Recovery rating is based on recovery efficiencies obtained in a CSA certified laboratory. N = Low NOx DIMENSIONAL INFORMATION (All dimensions shown in inches) MODEL APPROX. SHIPPING NUMBER A B C D E F G WEIGHT (LBS.) G / /2 180 G /2 58-1/2 21-3/ /4 180 G /4 13-1/ /4 320 G /8 65-3/4 28-1/ / Note: Meets 40ng/J Low NOx requirements. *FVIR compliant CLEARANCES TO COMBUSTIBLES MODEL REAR/ NUMBER SIDES FRONT TOP G " 3" 2" G " 3" 2" G " 3" 2" G " Alcove 12" NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITH FVIR MODELS 17

11 18 PowerVent Gas 75,000 BTU/HR. Standard Features: Uses 3" or 4" schedule 40 PVC, CPVC or ABS pipe Vents up to 95 feet Easy to install/maintain blower assembly Spark-to-pilot ignition system Low NOx burner Self-diagnostic thermostat/gas valve 2" rigid foam insulation 3 year limited warranty Factory installed AGA/ASME rated T&P relief valve Certified for a 150 PSI maximum working pressure Durable brass drain valve FVIR compliant POWER VENT ASSEMBLY G HOT WATER CONNECTION A B D 1/2" E C ANODE ROD G COLD WATER CONNECTION T&P FITTING 3/4" N.P.T. F SIDE TAPS DIMENSIONAL INFORMATION (All dimensions shown in inches) MODEL APPROX. SHIPPING NUMBER A B C D E F G WEIGHT (LBS.) GPV75-75FV /8 26-1/4 14-3/ / RECOVERY CAPACITIES MODEL INPUT BTU/HR. TEMPERATURE RISE - DEGREES F - GALLONS PER HOUR NUMBER NATURAL & L.P GPV75-75FV-2 75, GPV75-75PFV-2 70,

12 20 Power Vent kits Gas Manufactured by Tjernlund Products, Inc., Rheem-Ruud Commercial Gas Water Heater Power Vent Kits are your best choice for new construction, electric-to-gas conversions and renovations. For technical assistance, please call the Tjernlund Help Line at Construction Features: Certified for use on natural and propane gas models. Maximum venting length up to 50 feet equivalent including the vent terminal. Vent terminal can be installed through combustible or non-combustible surfaces heat shield is provided. Vent terminal is constructed from heavy-duty corrosion resistant aluminum. Venter can be connected to a vent termination on an exterior wall. Vibration isolators are supplied to provide quiet operation. Safety interlocks standard. Complete with mounting hardware. Venter is pre-wired with 40 feet of #18-4 copper wire (24 volt) to minimize field connections. TYPICAL APPLICATION Floor Exterior Wall Draft Vent Part Hood Vent Vent Model kit No. Outlet Size Adapter* G50-98 PV Kit 4 AP " 4" 5" x 4" G PV Kit 4 AP " 4" 5" x 4" G PV Kit 4 AP " 4" 6" x 4" G PV Kit 4 AP " 4" 6" x 4" G PV Kit 5 AP " 4" Not Req. G PV Kit 5 AP " 6" Not Req. G PV Kit 5 AP " 6" Not Req. G (A) PV Kit 5 AP " 6" Not Req. G72-250(A) PV Kit 5 AP " 6" Not Req. G (A) PV Kit 5 AP " 6" 8" x 6" G (A) PV Kit 5 AP " 6" 8" x 6" G72-300(A) PV Kit 5 AP " 6" 8" x 6" G85-300(A) PV Kit 5 AP " 6" 8" x 6" G (A) PV Kit 5 AP " 6" 7" x 6" G65-360(A) PV Kit 5 AP " 6" 8" x 6" G65-400(A) PV Kit 5 AP " 6" 8" x 6" G85-400(A) PV Kit 5 AP " 6" 10" x 6" G (A) PV Kit 5 AP " 6" 8" x 6" GD (A) PV Kit 5 AP " 6" Not Req. GD (A) PV Kit 5 AP " 6" Not Req. GD (A) PV Kit 5 AP " 6" Not Req. GD (A) PV Kit 5 AP " 6" Not Req. *Note: Vent Pipe and Vent Adapter are NOT included. POWER VENTER (from Tjernlund) Motor Motor Max Height Width Depth Inlet kit# Watts Amps Vent (H) (W) (D) Outlet ft 7-7/8" 11" 7" 4" ft 9-1/4" 11-5/8" 8-5/8" 6" Note: Max Vent Length based on total length of straight vent pipe plus 10 feet for each 90 degree elbow and 5 feet for each 45 degree elbow. H D W VENT TERMINAL Rough in kit# A B C Dimension 4 9" 9-1/2" 7" Sq. 8" Sq /8" 9-1/2" 8-1/2" Dia. 9" Dia. Power vent kits manufactured by Tjernlund Products, Inc. are tested and certified by CSA for use on these Rheem-Ruud Commercial Gas Heaters. Not for use with GN, GP, and GX models. A Sq. B C 21

13 22 Hot Water Supply Heaters Gas 136,000 1,826,000 BTU/HR. Standard Features: 82% thermal efficiency 5 year limited warranty Indoor and outdoor installations Meets ASHRAE standards Natural gas or L.P. Certified for a 160 PSI maximum working pressure Heat Exchanger: Finned copper tubes ASME steel tubesheet Silicon O-rings 125 PSIG ASME pressure relief valve Glasslined cast iron headers Controls: Energy saving pump control Flow switch Spark-to-pilot ignition system High limit control On/Off switch Flue gas spillage sensor Flame roll-out sensor Gas Control Train: Manual gas shut-off cock Main gas pressure regulator Safety shut-off valve, redundant Control valve SPECIFICATIONS AND DIMENSIONS MODEL NUMBER STYLE MBTUH NATURAL GAS (X 1000) DIMENSIONS (INCHES) SHIPPING WEIGHT With- Temperature Rise out With In- Out- (indoor) (outdoor) Gallons Per Hour Height Jac. Gas Flue Pump Pump door door Input Output Input Output 40 F 100 F 140 F Width Overall Ht. Conn. Dia. (Indoor) (Outdoor) GBB136* GBBP136* GBC186 GBCP GBC264 GBCP GBC331 GBCP GBC399 GBCP GBC512 GBCP GBC627 GBCP GBC726 GBCP GBC825 GBCP GBC926 GBCP GBC962 GBCP GBC1083 GBCP GBC1125 GBCP GBC1178 GBCP GBC1223 GBCP GBC1287 GBCP GBC1337 GBCP GBC1413 GBCP GBC1467 GBCP GBC1570 GBCP GBC1630 GBCP GBC1758 GBCP GBC1826 GBCP MBTUH PROPANE GAS Model Size Multiplier Same as natural gas Indoor.955 Outdoor (input).92 Outdoor (output) Multiplier x Nat. MBTUH = Pro. MBTUH ELECTRICAL RATINGS Model Size With Pump V (1/8 hp pump) V (1/6 hp pump) V (1/2 hp pump) Subtract 55 lbs. when ordering GBC models. *Equipped with bronze headers, all other models have glasslined cast iron headers. GBC cast iron headers. GBB bronze headers. Add N after model number for Low NOx configuration on models. 23

14 24 Large Volume High-Power Electric 12 KW 900 KW 208, 240, 277,380, 415, 480 and 600 Voltages Vertical Round,Vertical Square and Horizontal High Power Energy Saving Performance 150 to 2,500 Gallon Storage Rheem-Ruud large volume electric high power commercial water heaters are now available in 150 to 2,500 gallon storage vertical round, vertical square and horizontal with energy saving performance! Construction Features: Glass lined steel tank Incoloy heating elements Internal fusing (above 120 amps) Magnesium anodes Immersion thermostat Manual reset high limit ASME temperature and pressure relief valve Channel iron skid base (except 150 & 200 gallon round models) 180 F temperature operation 125 PSI working pressure Handhole cleanout 3 Year limited tank warranty Optional Features: Low water cut-off Pilot lights Manual limiting switches Alarm bell Shunt trip disconnect (Field installed) Low or high water pressure switch Lifting lugs Time clock (7 day or 24 hour) Safety door interlock Temperature and pressure gauges Manway (250 gallon and larger only) 150 psi or 160 psi working pressure Electronic step controller Seismic attachment point (250 gallon and larger specify city, state and seismic zone) Certification and Ratings: Efficiency All models meet or exceed ASHRAE energy efficiency standards. Safety and construction ASME construction and National Board listed UL 1453 listed Dimensional Information MODEL MAX. GALLON HEIGHT TO WATER CONNECTION APPROX. SHIP. NUMBER KW CAPACITY HEIGHT WIDTH DEPTH COLD INLET INLET OUTLET WEIGHT VERTICAL ROUND EVRO / /4 7-3/4 1-1/2 1-1/2 650 lbs. EVRO /4 7-3/4 1-1/2 1-1/2 750 lbs. EVRO /4 19-1/2 1-1/2 1-1/2 1,165 lbs. EVRO / ,350 lbs. EVRO /4 22-1/ ,590 lbs. EVRO /4 22-1/ ,700 lbs. EVRO /4 24-1/2 2-1/2 2-1/2 2,010 lbs. EVRO /4 24-1/2 2-1/2 2-1/2 2,450 lbs. EVRO /4 24-1/2 2-1/2 2-1/2 3,160 lbs. VERTICAL SQUARE EVS , /2 64-1/2 64-1/2 23-1/ ,560 lbs. EVS , /2 70-1/2 70-1/2 25-1/ ,120 lbs. EVS , /2 76-1/2 76-1/2 27-1/4" 3 3 4,350 lbs. EVS , /2 82-1/2 82-1/ ,750 lbs. HORIZONTAL EHS /2 34-1/ ,180 lbs. EHS / ,370 lbs. EHS /4 36-1/ ,450 lbs. EHS /4 42-1/4 14-3/ ,530 lbs. EHS /4 48-1/ ,750 lbs. EHS /4 48-1/ ,860 lbs. EHS /4 54-1/4 13-1/2 2-1/2 2 2,340 lbs. EHS /4 54-1/4 13-/12 2-1/2 2 2,850 lbs. EHS , /4 54-1/4 13-1/2 2-1/2 2 3,040 lbs. EHS , /4 60-1/ ,750 lbs. EHS , /4 66-1/ ,340 lbs. EHS , /4 72-1/4 17-1/ ,580 lbs. EHS , /4 78-1/4 16-1/ ,060 lbs. Vertical round models above 90 KW at 208V, 240V, or 380V and 162 KW at 415V, 480V or 600V exceed the capacity of a single control box and may require mulitple control panels. Consult the factory for specific details and optional construction. Vertical square construction is available as an option for models that exceed the listed KW limits. Control panel heights on vertical round models may exceed tank height consult factory for specific heights on models with inputs above 72 KW. 25

15 Heavy-Duty Electric 6 KW 81 KW 26 (With Optional Seal Kit) Standard Features: System Sentinel L.E.D. diagnostic system Surface mounted and immersion thermostat models available Lifeguard stainless steel elements 208, 240, 277 and 480 voltages 3 year limited tank warranty Manual reset high limit control Magnetic contactors and integral fusing 1-1/2" NPT inlet/outlet dielectric nipples factory installed 3" Rigid foam insulation Heavy duty anode rods Full port, full flow, brass drain valve Factory installed AGA/ASME rated T&P relief valve Certified for a 150 PSI maximum working pressure (160 PSI for ASME models) Options: UL Sanitation compliant models available Thermostat staging ASME construction available on E models 36 1 /8" 5" D C B 1 1 /2" HOT OUTLET NIPPLE SYSTEM SENTINEL AUTOMATIC TEMPERATURE CONTROL (IMMERSION ONLY) 1 1 /2" COLD INLET NIPPLE A MODEL NUMBERS SURFACE MOUNTED THERMOSTATS Tank Capacity In Gallons IMMERSION THERMOSTATS Tank Capacity In Gallons ES50-6-G ES85-6-G ES120-6-G E50-6-G E85-6-G E120-6-G ES50-9-G ES85-9-G ES120-9-G E50-9-G E85-9-G E120-9-G ES50-12-G ES85-12-G ES G E50-12-G E85-12-G E G ES50-15-G ES85-15-G ES G E50-15-G E85-15-G E G ES50-18-G ES85-18-G ES G E50-18-G E85-18-G E G ES50-24-G ES85-24-G ES G E50-24-G E85-24-G E G ES50-27-G ES85-27-G ES G E50-27-G E85-27-G E G ES50-30-G ES85-30-G ES G E50-30-G E85-30-G E G ES50-36-G ES85-36-G ES G E50-36-G E85-36-G E G ES50-45-G ES85-45-G ES G E50-45-G E85-45-G E G ES50-54-G ES85-54-G ES G E50-54-G E85-54-G E G N/A N/A N/A N/A E85A-81-GS E120A-81-GS RECOVERY CAPACITIES INPUT EQUIVALENT TEMPERATURE RISE DEGREES F GPH kw BTU/HR , , , , , , , , , , , , In accordance with ANSI test procedures, these models tested below the maximum allowable standby loss levels of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy codes of all states including California Energy Commission (CEC). DIMENSIONAL INFORMATION(All dimensions shown in inches) WATER TEMPERATURE RATINGS APPROX. SHIPPING MODEL WEIGHT (LBS.) NUMBER A B C D STD. ASME* E(S) /8 26-1/ / E(S) / / / E(2) /8 30-1/ / *ASME construction available only on Immersion Thermostat Models. All models are North Carolina Code compliant. Minimum Maximum High Model Thermostat Delivered Delivered Temperature Number Type Temperature Temperature Limit ES50 Surface 90 F 160 F 180 F ES85, ES120 Surface 120 F 160 F 190 F E50, E85, E120 Immersion 90 F 190 F 200 F 27

16 PowerPack Small Volume ASME Electric 3 KW 36 KW 28 (With Optional Seal Kit) Standard Features: System Sentinel L.E.D. diagnostic system Immersion thermostat Lifeguard stainless steel elements 208, 240, 277 and 480 voltages 3 year limited tank warranty Manual reset high limit control Magnetic contactors and integral fusing 3/4" couplings 2-1/2" Rigid foam insulation Heavy duty anode rods Brass drain valve Factory installed AGA/ASME rated T&P relief valve Certified for a 160 PSI maximum working pressure All models ASME certified Options: UL Sanitation compliant ring seal kits available B 8" 3 /4" T&P A E 4 1 /4" 2 1 /2" D C SYSTEM SENTINEL AUTOMATIC TEMPERATURE CONTROL INPUT kw MODEL NUMBERS IMMERSION THERMOSTATS Tank Capacity In Gallons E12A-3-G E20A-3-G E30A-3-G E40A-3-G E12A-6-G E20A-6-G E30A-6-G E40A-6-G E12A-9-G E20A-9-G E30A-9-G E40A-9-G N/A E20A-12-G E30A-12-G E40A-12-G N/A E20A-15-G E30A-15-G E40A-15-G N/A E20A-18-G E30A-18-G E40A-18-G N/A N/A E30A-24-G E40A-24-G N/A N/A E30A-27-G E40A-27-G N/A N/A E30A-30-G E40A-30-G N/A N/A E30A-36-G E40A-36-G DIMENSIONAL INFORMATION All dimensions shown in inches MODEL In accordance with ANSI test procedures, these models tested below the maximum allowable standby loss levels of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy codes of all states including California Energy Commission (CEC). APPROX. SHIPPING WEIGHT (LBS.) NUMBER A B C D E ASME E12A 28-1/ /4 14-3/4 26-1/4 135 E20A 36-1/ /4 14-3/4 26-1/4 160 E30A 49-1/ /4 14-3/4 32-1/2 192 E40A 53-3/ /4 16-1/2 32-1/2 228 WATER TEMPERATURE RATINGS Model Tank Capacity Thermostat Minimum Delivered Maximum Delivered High Temperature Number Gallons Type Temperature Temperature Limit E12A 13 Immersion 90 F 190 F 200 F E20A 19.9 Immersion 90 F 190 F 200 F E30A 30 Immersion 90 F 190 F 200 F E40A 40 Immersion 90 F 190 F 200 F RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises INPUT EQUIVALENT 40 F 60 F 80 F 100 F 120 F 140 F kw BTU/HR. (22.2 C) (33.3 C) (44.4 C) (55.6 C) (66.7 C) (77.8 C) 3 10, , , , , , , , , , All models are North Carolina and Massachusetts Code compliant. 29

17 Eclipse 10-Year Electric 12 KW 24 KW 30 Standard Features: 85 and 105 gallon models EXCLUSIVE 10 YEAR LIMITED TANk WARRANTY! D Inputs from 12, 18 and 24 KW Staged element operation 208, 240, 277 and 480 voltages, single or three phase Plastic tank design no anode rods (4) Inconel heating elements System Sentinel LED diagnostic system Full port, full flow, brass drain valve UL Sanitation listed Less than half the weight of steel construction Industry leading stand-by loss efficiencies B C A INPUT kw MODEL NUMBERS SURFACE MOUNTED THERMOSTATS Tank Capacity In Gallons ME85-12-G ME G ME85-18-G ME G ME85-24-G ME G In accordance with ANSI test procedures, these models tested below the maximum allowable standby loss levels of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy codes of all states including California Energy Commission (CEC). WATER TEMPERATURE RATINGS Minimum Maximum Tank Capacity Thermostat Delivered Delivered Gallons Type Temperature Temperature 85 Surface Surface DIMENSIONAL INFORMATION All dimensions shown in inches MODEL APPROX. SHIPPING WEIGHT (LBS.) NUMBER A B C D ASME 85 Gals 28-1/4 66-1/4 70-1/4 4-1/ Gals. 30-1/4 66-1/2 70-3/4 4-1/2 185 RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) at Various Temperature Rises INPUT EQUIVALENT kw BTU/HR. 40 F 60 F 80 F 100 F 120 F 12 40, , ,

18 Booster Electric 6 KW 54 KW 32 Standard Features: System Sentinel L.E.D. diagnostic system Immersion thermostats Manual reset high limit control 208, 240, 277 and 480 voltages 3 year limited tank warranty Magnetic contactors and integral fusing Heavy duty anode rods Durable brass drain valve Factory installed AGA/ASME rated T&P relief valve 6" stainless steel legs UL Sanitation compliant Certified for a 150 PSI max working pressure Factory Accessories Solid state low water cut-off Pressure reducing valve with bypass RECOVERY CAPACITIES MODEL INPUT EQUIVALENT TEMPERATURE RISE DEGREES F GPH NUMBER kw BTU/HR E10-6-G 6 20, E10-9-G 9 30, E10-12-G 12 40, E10-15-G 15 51, E10-18-G 18 61, E10-24-G 24 81, E10-27-G 27 92, E10-30-G , E10-36-G , E10-45-G , E10-54-G , Approximate Weight 110 Lbs. WATER TEMPERATURE RATINGS 3/4" T&P 21 3 /4" Minimum Maximum High Gallon Thermostat Delivered Delivered Temperature Capacity Type Temperature Temperature Limit 10 Immersion 90 F 190 F 200 F 17" 13 3 /4" 6" 5 3 /4" 8 1 /4" INLET 4 3 /4" OUTLET CONTACTORS FUSE BLOCKS (FUSED MODELS ONLY) TRANSFORMER TERMINAL BLOCK 1 1 /4" HOT OUTLET NIPPLE 1 1 /4" COLD INLET NIPPLE OPTIONAL THERMOSTATS (-GS MODELS ONLY) THERMOSTAT TEMPERATURE LIMIT CONTROL 21 1 /2" ELEMENT AND CLEANOUT ACCESS PANEL These models meet the energy efficiency levels of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). All models are North Carolina Code compliant. 33

19 Light-Duty Electric 3 KW 12 KW 34 Standard Features: 208, 240, 277, and 480 voltages Porcelain enamel lined tank Heavy duty anode rod 2-1/2" of rigid foam insulation Baked enamel steel jacket Patented resistor heating elements Surface mounted thermostat Manual reset high limit control 3 year limited warranty Certified for a 150 PSI maximum working pressure Factory installed AGA/ASME rated T&P relief valve Durable brass drain valve A HOT WATER CONNECTION 3/4" T&P B DIA. 8" COLD WATER CONNECTION ANODE ROD WATER CONNECTIONS ALL 3/4" NPT ELECTRICAL CHARACTERISTICS AND CAPACITIES (Non-Simultaneous/Single or Three Phase Operation) ELEMENT RECOVERY CAPACITIES GPH FULL LOAD CURRENT (AMPS) TEMPERATURE RISE OF (ALL TERMINALS) UPPER/LOWER / / / / / ELECTRICAL CHARACTERISTICS AND CAPACITIES (Simultaneous/Three Phase Operation) ELEMENT RECOVERY CAPACITIES GPH FULL LOAD CURRENT (AMPS) TEMPERATURE RISE OF (TERMINAL L3/TERMINALS L1 & L2) UPPER/LOWER / / / / / / / / / / / / / / / / / N/A 43.3/ /12.5 DIMENSIONAL INFORMATION (All dimensions shown in inches) MODEL TANk CAPACITY APPROX. SHIPPING NUMBER GALLONS A B WEIGHT (LBS.) ELDS /2 22-1/4 105 ELDS / ELDS /2 26-1/4 150 ELD /2 17-3/4 90 ELD /4 22-1/4 108 ELD /4 127 ELD / ELD /2 200 ELD /2 28-1/4 330 WATER TEMPERATURE RATINGS: Thermostat Type: Surface Mounted Min. Delivered Temperature: 110 F Max. Delivered Temperature: 170 F High Temperature Limit: 190 F These models have been tested according to DOE test procedures, and exceed the minimum energy factor requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy codes of all states including California Energy Commission (CEC). All models are North Carolina and Massachusetts Code compliant. 35

20 Point-of-Use Electric 1,440 6,000 WATTS 36 Standard Features: 120, 208, 240, 277 and 480 voltages Porcelain enamel lined tank Heavy duty anode Rigid foam insulation Baked enamel steel jacket Resistor heating element Surface mounted thermostat Manual reset high limit control 3 year limited warranty Certified for a 150 PSI maximum working pressure Factory installed AGA/ASME rated T&P valve Optional wall mounting kit These models meet the minimum energy factor requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy codes of all states including California Energy Commission (CEC). All models are North Carolina and Massachusetts Code compliant. ELEMENT AVAILABILITY WATTAGE 120 V 208 V 240 V 277 V 480 V 1,440 **Y N/A N/A N/A N/A 1,500 Y Y **Y N/A N/A 2,000 Y Y Y Y Y 2,500 Y Y Y N/A N/A 3,000 Y Y Y Y Y 4,500 N/A Y *Y *Y *Y 6,000 N/A Y Y Y Y *Not available in EGSP6 & EGSP10 **EGSP2 available only in these configurations. DIMENSIONAL INFORMATION (All dimensions shown in inches)* MIN MAX TANk MODEL WATTS WATTS GALLONS SHIPPING A B C D E WEIGHT (LBS.) EGSP2 1,440 1, / /4 18 EGSP6 1,500 6, /8 15-3/4 12-5/8 11-5/8 4-1/4 41 EGSP10 1,500 6, /8 15-3/4 20-3/8 19-3/8 4-1/4 53 EGSP15 1,500 6, /4 17-3/4 21-7/8 19-3/8 4-5/8 65 EGSP20 1,500 6, /8 19-3/4 22-5/8 19-5/8 5-1/8 76 EGSP30 1,500 6, / /4 115 Basic model numbers are listed. When ordering specify electrical input to determine specific model number: Basic Model: EGSP6 Specified Input: 6,000 Watts Specified Model Number: EGSP6-6 Use CEGSP Prefix for Canadian Models. MODELS: EGSP6 EGSP10 EGSP15 EGSP20 EGSP30 HOT WATER OUTLET C A Water Connections 3/4" NPT D COLD WATER INLET B 3/4" T&P E A B DIA. Water Temperature Ratings: Thermostat Type: Surface Mounted Min. Delivered Temperature: 110 F Max. Delivered Temperature: 170 F High Temperature Limit: 190 F HOT WATER CONNECTION 3/4" T&P MODEL: EGSP2 Water Connections 1/2" NPT 3 1 /2" COLD WATER CONNECTION ELECTRICAL CHARACTERISTICS ELEMENT FULL LOAD CURRENT IN AMPERES WATTAGE 120 V 208 V 240 V 277 V 480 V 1, N/A N/A N/A N/A 1, N/A N/A 2, , N/A N/A 3, ,500 N/A ,000 N/A All models employ 1 heating element resulting in a 2-wire outlet (single phase) electrical configuration. RECOVERY CAPACITIES TEMPERATURE RISE - DEGREES F - ELEMENT GALLONS PER HOUR WATTAGE 40 F 60 F 80 F 100 F 120 F 140 F 1, , , , , , ,

21 Indirect Water Heaters 38 Construction Features: 30, 38, 45, 75 and 110 gallon models Heavy gauge steel tank High temperature porcelain enamel protect all tank and coil Factory installed automatic temperature controls Factory installed brass drain valve Temperature and pressure relief valve 1-1/2" coil diameter 2" Non-CFC foam insulation Two heavy-duty magnesium anode rods Factory installed dielectric nipples Hot Outlet, 1-1/2" NPT Anode Anode Rod Rod T&P Relief Valve From Boiler, 1" NPT B C Aquastat Drain Valve D To Boiler, 1"NPT E F H G A Cold Inlet, 1" NPT STID80 & STID120 STID30, STID40 & STID50 DIMENSIONAL INFORMATION MODEL APPROX. SHIPPING NUMBER UNITS A B C D E F G H WEIGHT STID30 inches /4 27-3/4 18-1/2 11-3/4 6-1/2 4-1/2 N/A 180 lbs STID40 inches /4 34-3/4 31-1/2 16-3/4 6-1/2 4-1/2 N/A 226 lbs STID50 inches /4 39-3/4 31-1/2 16-3/4 6-1/2 4-1/2 N/A 231 lbs. STID80 inches /8 57-1/ / lbs. STID120 inches /4 57-3/4 33-3/4 16-1/4 8-3/ /2 397 lbs. FIRST HOUR RATING Coil Output (Btu/hr) TANK FIRST HEAT SOURCE MODEL CAPACITY DRAW FRICTION LOSS* 180 F, 180 F, 180 F, 200 F, 200 F, 200 F, 200 F, NUMBER (GAL) (GAL) (FT. W.C.) 8 GPM** 10 GPM** 12 GPM** 8 GPM** 10 GPM** 12 GPM** 14 GPM** STID ,000 57,000 58,000 71,000 75,000 78,000 81,000 STID ,000 96, , , , , ,000 STID ,000 96, , , , , ,000 STID , , , , , , ,000 STID , , , , , , ,000 All data obtained through testing in accordance with GAMA INDIRECT-FIRED WATER HEATERS TESTING STANDARD IWH-TS-1_MARCH 2003 *At 8 GPM **Coil Input (temperature, flow rate). Ratings based on 77 F rise with 58 F inlet potable water. Note: First Hour Rating = First Dray + Continuous Draw Warning: Installation should be in accordance with all national and/or local codes. In the absence of local codes, refer to NFPA 54 or ANSI Z Caution: The recommended maximum hot water temperature setting for normal residential use is 120 F. Rheem recommends a tempering valve or anti-scald valve be installed and used according to the manufacturer s directions to prevent scalding. Pressures (all): Test pressure, 300 psi; working pressure, 150 psi Standard Voltage (all): 120V, 60 Hz, 1P T&P valve installed 39

22 Storage Tanks GAL. 40 Standard Features: Porcelain enamel lined tank Heavy duty anode rods ASME construction available 2" of rigid foam insulation Baked enamel steel jacket 5 year limited warranty These models exceed the minimum efficiency requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact). DIMENSIONAL INFORMATION (DIMENSIONS SHOWN IN INCHES) WATER CONNECTIONS APPROX. MODEL TOP FRONT WEIGHT (LBS.) NUMBER A B C D OUTLET SIDES STANDARD ASME ST80(A) 58-5/ / /16 6-3/ lbs. 260 lbs. ST100(A) /4 12-9/16 5-9/ lbs. 475 lbs. ST120(A) 59-1/4 28-1/4 11-1/16 4-1/ lbs. 340 lbs. ST175(A) 67-1/4 32-1/4 12-9/16 5-9/16 2-1/2 2-1/2 600 lbs. 600 lbs. 3/4" NPT THERMOMETER OPENING B T&P OPENING HOT OUTLET OPENING 1" NPT T&P OPENING HOT B 3/4" NPT THERMOMETER OPENING TANk INFORMATION 3/4" NPT AQUASTAT OPENING TANk MAXIMUM WORkING MODEL CAPACITY PRESSURE 39-15/16 A NUMBER (GALLONS) STD. ASME 2 OPENINGS FOR CIRCULATING CIRCULATING ST80(A) PSI 125 PSI CONNECTIONS LINES ST100(A) PSI 160 PSI C D ST120(A) PSI 160 PSI D C ST175(A) PSI 150 PSI 3/4" NPT DRAIN OPENING ST100(A) ST80(A), ST120(A), ST175(A) 3/4" NPT AQUASTAT OPENING A 41

23 Large Volume Storage Tanks GAL. 42 Standard Features: Available in jacketed and non-jacketed models 200, 260, 320, 430, 500, 750 and 950 gallon capacities Porcelain enamel lined tank Heavy duty anode rods 2" of rigid foam insulation Baked enamel steel jacket 5 year limited warranty All large volume commercial storage tanks are certified to ASME heater and pressure vessel code standards 1-1/4" NPT T&P (ST260A AND ABOVE) 2" NPT B A 1" DRAIN PIPE 2" B 3/4" 4" 1" NPT RELIEF VALVE OPENING (ST200A) 3/4" NPT AQUASTAT OPENING D C A D C TANk INFORMATION (Shown in English & Metric) MAXIMUM MODEL TANk CAPACITY WORkING PRESSURE NUMBER GALLONS LITERS ASME ST(U)200A PSI 1034 kpa ST(U)260A PSI 862 kpa ST(U)320A PSI 862 kpa ST(U)430A PSI 862 kpa ST(U)500A PSI 862 kpa ST(U)750A PSI 862 kpa ST(U)950A PSI 862 kpa DIMENSIONAL INFORMATION FOR VERTICAL ROUND JACkETED STORAGE TANkS (All dimensions shown in English and Metric) WATER CONNECTIONS APPROX. MODEL TOP FRONT NUMBER UNITS A B C D OUTLET SIDE SHIPPING WEIGHT ST200A inches 77-1/ /2 17-1/ /2 500 lbs. mm kgs. ST260A inches 95-1/ lbs. mm kgs. ST320A inches 84-1/ /4 27-1/ lbs. mm kgs. ST430A inches 84-1/ lbs. mm kgs. ST500A inches 94-1/ lbs. mm kgs. ST750A inches 107-1/ /8 30-7/ lbs. mm kgs. ST950A inches 131-1/ /8 30-7/ lbs. mm kgs. DIMENSIONAL INFORMATION FOR VERTICAL BARE (NON-JACkETED) STORAGE TANkS (All dimensions shown in English and Metric) WATER CONNECTIONS APPROX. MODEL TOP FRONT NUMBER UNITS A B C D OUTLET SIDE SHIPPING WEIGHT STU200A inches 75-3/ / lbs. mm kgs. STU260A inches /4 23-3/ lbs. mm kgs. STU320A inches /8 25-3/ lbs. mm kgs. STU430A inches /8 26-7/ lbs. mm kgs. STU500A inches /8 26-7/ lbs. mm kgs. STU750A inches /8 28-7/ lbs. mm kgs. STU950A inches /8 28-7/ lbs. mm kgs. Jacketed models meet or exceed the minimum efficiency requirements of ASHRAE (Part of the Federally mandated Energy Policy Act (EPact). 43

24 44 Trouble Zone Easy- to- Install Zone 156,000 BTU 199,900 BTU 250,000 BTU 300,000 BTU 360,000 BTU 399,900 BTU Competitors larger units mean a difficult installation. Universal s heavy duty gas models are shorter and narrower for easy and convenient installation. CertiSpec 3.2 What s new? 32-bit upgrade! What does that mean? Well, nothing you can see or touch, but this major enhancement is the engine that drives many of the new features. New Features: Internet Upgrades! No more new versions Internet or mail-in registration (no mandatory registration either!) Fuel Cost Calculator User defined (imported) business logo/info on job spec document Long File Name recognition Most recent projects listed under File Menu Multiple open projects Direct CS3 to CS3 attachment of project file NOW INCLuDES SPIDERFIRE MODELS! Additional Models: SPIDERfire sizing Small Volume ASME cross reference Low NOx sizing Large Volume Storage Tank reference Computer Requirements: Windows 95/98 or NT 4.X Pentium 90 or higher required 16 megabyte RAM (32 recommended) Disk Space: 4-6 megabytes (estimated) Internet connection required for and Upgrade Download 800 x 600 screen resolution 45

Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications

Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications Ruud Commercial Gas Universal Water Heaters Universal is a family of commercial gas water heaters that are designed to fit into tight retrofit applications Features & Benefits The tighter the commercial

More information

Date: Project #: Engineer: Prepared By: Bid Date:

Date: Project #: Engineer: Prepared By: Bid Date: NEOTHERM Hydronic Boiler NTH Hydronic Boiler Indoor Sizes 285-850 Date: Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment High condensing

More information

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve NEOTHERM Hydronic Boiler NTH Hydronic Boiler Date: Indoor Sizes 285-850 Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment Large LCD display

More information

Hamilton 3VO Submittal

Hamilton 3VO Submittal Job RESET FORM Engineer Hamilton 3VO Submittal BOILER s H3H 750 WATER HEATER s H3D 750 Contractor Prepared By Date Input 100% factory fire tested Efficiency: up to 99.8% (based on incoming water) Maximum

More information

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace RGTK- Series 92% A.F.U.E. or Above 60-120 kbtu with Dual Comfort Control A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-100 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace THIS MODEL Air Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801S- (Upflow/Horizontal) Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Classic Plus Series Downflow Gas Furnace

Rheem Classic Plus Series Downflow Gas Furnace Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Value Series Downflow Gas Furnace

Rheem Value Series Downflow Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Value Series Downflow Gas Furnace RGLS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE MID A.F.U.E.

More information

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Classic Series Downflow Gas Furnace

Rheem Classic Series Downflow Gas Furnace Gas Furnaces Rheem Classic Series Downflow Gas Furnace R801S (Downflow) Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace R802V- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization

More information

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces THIS MODEL 78% 82% 88% 92.0% 97% Air Gas Furnaces Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces RGPQ- Series 80% A.F.U.E. Models with Input Rates from 45-105 kbtu (U.S. & Canadian Models)

More information

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace RGPT- Series 80% A.F.U.E. Input Rates 50-125 kbtu ENER UIDE Annual Fuel Utilization Efficiency

More information

Trade Price Book - 816

Trade Price Book - 816 Trade Price Book - 816 Effective 8/29/16 Green Mountain Gas-Fired Boilers Customer Service Corporate Sales Literature Technical Support Phone: 877-386-5475 literature@ecrinternational.com Phone: 800-325-5479

More information

COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A

COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A CATALOG NO. 9300.90 Effective: 12-13-13 Replaces: NEW RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 1005A, 1505A & 2005A MODEL TYPES: MODULATING VERTICAL BOILER

More information

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace Gas Furnaces Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace U802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces

More information

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark

More information

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL

More information

UPFLOW/ HORIZONTAL GAS FURNACE

UPFLOW/ HORIZONTAL GAS FURNACE FORM NO. GFJ-542 UPFLOW/ HORIZONTAL GAS FURNACE Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark Ignition for reliability and longevity

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. ) FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and

More information

Rheem Value Series Upflow/Horizontal Gas Furnace

Rheem Value Series Upflow/Horizontal Gas Furnace THIS MODEL Gas Furnaces Rheem Value Series Upflow/Horizontal Gas Furnace RGPS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE 80.0% MID HIGH 78% 82% 88%

More information

G23 Bulletin # September 1998 Supersedes June 1995

G23 Bulletin # September 1998 Supersedes June 1995 ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features

More information

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) FORM NO. G66-544 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

Electric Resistance Boilers Steam or Hot Water

Electric Resistance Boilers Steam or Hot Water Electric Resistance Boilers Steam or Hot Water CONTENTS FEATURES AND BENEFITS...................................................... 3 PRODUCT OFFERING..........................................................

More information

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign 3450 RPM Motor, squirrel cage blower, panel with 2 lights (power and main fuel) and control switch Gas electric pilot and gas ignition transformer Leakage test cock, pilot cock and main gas cock Pilot

More information

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G22-485 REV. 4 Supersedes Form No. G22-485 Rev. 3 GAS FURNACES UGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

G8MVL. Product Specifications

G8MVL. Product Specifications 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Supports two stage cooling units Flame roll out sensors standard Category I venting Blocked vent switch Dehumidification feature in

More information

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE FORM NO. G22-448 REV. 10 Supersedes Form No. G22-448 Rev. 9 GAS FURNACES UGPH- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE IMMERSION FIRED HOT WATER BOILER April 1, 2003 GENERAL DESCRIPTION The Sellers immersion fired hot water boiler is a horizontal, single pass, firetube boiler designed to burn natural gas. The unique burner

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-485 REV. 5 Supersedes Form No. G11-485 Rev. 4 GAS FURNACES RGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity

More information

Submittal Sheet for Heavy Duty Commercial Electric Water Heaters

Submittal Sheet for Heavy Duty Commercial Electric Water Heaters Advanced Heating and Hot Water Systems P.O. Box 429 120 Braley Road East Freetown, MA 02717 508-76-8071 Fax: 508-76-769 Submittal Sheet for Heavy Duty Commercial Electric Water Heaters JOB NAME: LOCATION:

More information

Replacement Parts List

Replacement Parts List Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Copper-Fin II Boilers Water Heaters CH CF 992-2072 50 17

More information

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design 80% AFUE GAS FURNACE Multipoise Design WFEL Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

More information

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & 101

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST RAYPAK ILLUSTRATED PARTS LIST The parts listed are for standard equipment for this model type. Raypak reserves the right to substitute, delete or change any part without notification. The addition of options

More information

Includes electric operated valve Pressure gauge with siphon, vacuum breaker and air vent BOILER UNITS

Includes electric operated valve Pressure gauge with siphon, vacuum breaker and air vent BOILER UNITS STEAM / HOT WATER MODELS HWG FEATURES A. O. Smith hot water generators are available for operation with steam or boiler water as the energy source. They are completely assembled with components sized,

More information

Heater Parts. LXi Low NOx. See Detail on next page Zodiac Pool Systems, Inc. Product Catalog. Heater Parts. After. July Before.

Heater Parts. LXi Low NOx. See Detail on next page Zodiac Pool Systems, Inc. Product Catalog. Heater Parts. After. July Before. LXi Low NOx 47 23 After July 2009 23 65 48 33 28 65 50 49 Before July 2009 22 26 Detail 22 63 64 25 67 25 9 62 33 27 6 34 35 62 4 36 2 32 20 57 60 8 72 58 59 7 52 56 4 54 53 7 68 70 69 90 55 6 See Detail

More information

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-547-1000 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KH 55 thru 285 44 3 4 43 2 47 46

More information

Table of Contents GF801U Series

Table of Contents GF801U Series FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed

More information

JANDY HEATERS A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS

JANDY HEATERS A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS JANDY HEATERS Heaters H-58 A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS E-Z FIND CHART MARK V XE XE SERIES I SERIES I MILLIVOLT MILLIVOLT ELECTRONIC MILLIVOLT ELECTRONIC DM, DR EG ES, EC EPG EPS,

More information

Ultra High Efficiency (ef Series ) 60 and 100 Gallon Models

Ultra High Efficiency (ef Series ) 60 and 100 Gallon Models COMMERCIAL GAS REPLACEMENT PARTS LIST Ultra High Efficiency (ef Series ) 60 and 100 Gallon Models Including: 100 Gallon Top Water Connections 100 Gallon Side Water Connections (-2 series) 60 Gallon Side

More information

One system. One company.

One system. One company. One system. One company. The prepackaged, specially engineered solar water heating system includes all of the components needed for a standard installation from the solar collectors, to the pump station

More information

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-486 REV. 3 Supersedes Form No. G11-486 Rev. 2 GAS FURNACES RGPP- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

ULTRA HIGH EFFICIENCY MODELS WITH DIRECT SPARK IGNITION

ULTRA HIGH EFFICIENCY MODELS WITH DIRECT SPARK IGNITION RESIDENTIAL AND COMMERCIAL GAS REPLACEMENT PARTS LIST ULTRA HIGH EFFICIENCY MODELS WITH DIRECT SPARK IGNITION EFR160T120*(EN,SX) EF(60,100)T(125-300)(E*N)(*X)(A)2 (Serial Number GB13006174 and AFTER) Includes

More information

Q SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER

Q SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER Models Q90-25 Q90-50 Q90-75 Q90-200 Q90 25-200 SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER REPAIR PARTS, OPTIONAL KITS Ordering Instructions Order Parts through your nearest supplier. When

More information

Power Direct Vent PDV T Model

Power Direct Vent PDV T Model REPLACEMENT PARTS LIST Power Direct Vent PDV T Model Includes Hydrojet Sediment Reduction System Effective: January, 2012 ECO 7731 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING REPLACEMENT

More information

GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER ( MBH) REPAIR PARTS MANUAL. P/N , Rev. 1.2 [02/06]

GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER ( MBH) REPAIR PARTS MANUAL. P/N , Rev. 1.2 [02/06] GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER (25-200 MBH) REPAIR PARTS MANUAL P/N 24000523, Rev..2 [02/06] TABLE OF CONTENTS I. Circulator Pumps (Optional)...2 II. Burner Assembly...3 III. Boiler

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST COMMERCIAL MODELS: MVB 503A THRU 2003A CATALOG NO. 9300.744 Effective: 12-01-17 Replaces: 03-01-17 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 503A, 753A, 1003A, 1253A, 1503A, 1753A & 2003A MODEL TYPES:

More information

Figure 1-1(d) Tft Installation Kit

Figure 1-1(d) Tft Installation Kit TRINITY TFT60-399 PARTS LIST For a list of parts that corresponds to the item numbers in the callouts, refer to Table 1-1. Note that some item numbers may appear more than once in the parts list depending

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST COMMERCIAL/POOL MODELS: MVB 504A THRU 2004A CATALOG NO. 9300.745 Effective: 11-01-18 Replaces: 12-01-17 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 504A, 754A, 1104A, 1504A & 2004A MODEL TYPES: MODULATING

More information

Q SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER

Q SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER Models Q90-25 Q90-50 Q90-5 Q90-200 Q90 25-200 SERIES II GAS-FIRED DIRECT VENT CONDENSING HOT WATER BOILER REPAIR PARTS, OPTIONAL KITS Ordering Instructions Order Parts through your nearest supplier. When

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G66-496 REV. 5 Supersedes Form No. G66-496 Rev. 4 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G66-495 Supersedes Form No. P66-765 Rev. 3 80PS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80% A.F.U.E. UPF/ HORIZONTAL GAS FURNACES The WeatherKing line of upflow/horizontal

More information

F8MTL. Product Specifications

F8MTL. Product Specifications 80% Two Stage Heating Furnace EASIER TO SELL 80% AFUE Suppts two stage cooling units Flame roll out senss standard Categy I venting Blocked vent switch Dehumidification feature in cooling 24 VAC and 115

More information

HE, HEII and VHE Section and Base Assembly

HE, HEII and VHE Section and Base Assembly HE, HEII and Section and Base Assembly 68 Discontinued Service s HE, HEII and Section and Base Assembly GAS s not listed below are obsolete and no longer available. s listed below may become obsolete.

More information

IMMERSION FIRED HOT WATER BOILER

IMMERSION FIRED HOT WATER BOILER 918 W WALNUT ST, DANVILLE, KENTUCKY 40422-0048 PHONE (859) 236-3181 www.sellersmfg.com SPECIFICATION SHEET NO. 8301 IMMERSION FIRED HOT WATER BOILER GENERAL DESCRIPTION The Sellers immersion fired S-Series

More information

Ultra High Efficiency Models With Direct Spark Ignition

Ultra High Efficiency Models With Direct Spark Ignition RESIDENTIAL AND COMMERCIAL REPLACEMENT PARTS LIST Ultra High Efficiency Models With Direct Spark Ignition EFR160T120*(EN,SX) EF(60,100)T(125-300)(E*N)(*X)(A)2 (Serial Number GB13006174 and AFTER) Includes

More information

COMMERCIAL and POOL MODELS: 302C THROUGH 902C

COMMERCIAL and POOL MODELS: 302C THROUGH 902C COMMERCIAL and POOL MODELS: 302C THROUGH 902C CATALOG NO. 9300.753 Effective: 12-01-17 Replaces: 12-01-16 RAYPAK REPLACEMENT PARTS MODEL SIZES: 302C, 402C, 502C, 652C, 752C & 902C MODEL TYPES: HI DELTA

More information

15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS

15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.

More information

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas

More information

Crest Heating Boilers FBN(L)

Crest Heating Boilers FBN(L) Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 59 IMG01113 52 65

More information

BOILER RATINGS. Net Ratings Oil Gas

BOILER RATINGS. Net Ratings Oil Gas POWER BURNER Series TC II Large Commercial s -, Assembled Block or Individual Sections Forced Draft ing Power s - Oil, Gas, Gas/Oil or Hot s Optional Tankless Coils Increased Efficiencies Oil Input GPH

More information

GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS & OPTIONAL ACCESSORIES

GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS & OPTIONAL ACCESSORIES GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOILER PARTS, KITS & OPTIONAL ACCESSORIES Models (Series B) BW9AAN00025 BW9AAN00050 BW9AAN00075 BW9AAN000200 CAC/BDP 730 West Morris St. Indianapolis, IN.

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 5 Supersedes Form No. G66-478 Rev. 4 80PJ SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

XIII. Repair Parts 106

XIII. Repair Parts 106 XIII. Repair Parts All Alpine Repair Parts may be obtained through your local authorized U.S. Boiler Company representatives or outlets. Should you require assistance in locating a U.S. Boiler Company

More information

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.

More information

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN WFAR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev V

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev V Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 615-889-8900 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Armor Condensing Water Heater AW 151 thru 801 41 4 10 38

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

KG7T (E and N Series)

KG7T (E and N Series) TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

CGa - Series 1 & 2 Section Assembly Parts

CGa - Series 1 & 2 Section Assembly Parts CGa - Series & Section Assembly Parts 0 Part Description Mfr. Mfr. s Part Boiler -0-0 End Section, Left Hand, Cast # -0- End Section, Right Hand, Cast # -0- Intermediate Section, Cast #, -- -- Replacement

More information

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa) 80% Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out senss standard Categy I venting Blocked vent switch Louvered do 24 VAC and 115 VAC humidifier terminal Electronic air cleaner terminal

More information

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev W

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev W Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Armor Condensing Water Heater AW 151 thru 801 41 4 10 38

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST RAYPAK ILLUSTRATED PARTS LIST The parts listed are for standard equipment for this model type. Raypak reserves the right to substitute, delete or change any part without notification. The addition of options

More information

RAYPAK REPLACEMENT PARTS

RAYPAK REPLACEMENT PARTS POOL MODELS: 206A THRU 406A ATMOSPHERIC RAYPAK REPLACEMENT PARTS MODEL SIZE: 206A, 266A, 336A & 406A MODEL TYPE: DATE OF MANUFACTURE: 10-22-04 THRU CURRENT CATALOG NO. 9100.56 Effective: 11-20-13 Replaces:

More information

SPECIFICATIONS DOUGLAS MODEL LD-20 POT, PAN, AND UTENSIL WASHER

SPECIFICATIONS DOUGLAS MODEL LD-20 POT, PAN, AND UTENSIL WASHER B05D PAN WASHER B05D PAN WASHER xxxxxx Effective: March 1, 2005 SPECIFICATIONS DOUGLAS MODEL LD-20 POT, PAN, AND UTENSIL WASHER CABINET 50 wide x 36 deep x 73 high Clearance Height: 100-3/4 (103-1/2 with

More information

Rheem High Efficiency Air Handler

Rheem High Efficiency Air Handler Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable

More information

Replacement Parts List

Replacement Parts List Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 615-889-8900 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Copper-Fin 2 Commercial Pool Heaters CP 992-2072 51 16 19

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST COMMERCIAL and POOL MODELS: 992B THRU 2342B CATALOG NO. 9300.762 Effective: 11-30-12 Replaces: 05-13-11 RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 992B, 1262B, 1532B, 1802B, 2002B, 2072B & 2342B MODEL

More information

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED CONDENSING REMOTE SYSTEMS UNITS 50hz HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM 3.6 to 16.0 kw (12 200 to 54 700 Btuh) HS18 Bulletin

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

UB95M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler

UB95M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler UB9M-200 Gas-Fired Direct Vent Modulating Hot Water Boiler Repair Parts Manual Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model Number and Serial Number

More information

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN WFSR Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to

More information

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved

More information