Installation Manual Type DDR DIN rail power supply Series DDR-120, DDR-240
|
|
- Brian Shelton
- 5 years ago
- Views:
Transcription
1 Type:DDR DIN rail power supply(series:ddr-120, DDR-240) DDR-120A-12 INPUT: 9~18VDC 13.5A OUTPUT: 12V 7.1A (9~10.8Vin) 12V 8.3A (10.8~18Vin) DDR-120A-24 INPUT: 9~18VDC 13.5A OUTPUT: 24V 3.6A (9~10.8Vin) 24V 4.2A (10.8~18Vin) DDR-120A-48 INPUT: 9~18VDC 13.5A OUTPUT: 48V 1.8A (9~10.8Vin) 48V 2.1A (10.8~18Vin) DDR-120B-12 INPUT: 16.8~33.6VDC 9A OUTPUT: 12V 9A (16.8~21.6Vin) 12V 10A (21.6~33.6Vin) DDR-120B-24 INPUT: 16.8~33.6VDC 9A OUTPUT: 24V 4.5A (16.8~21.6Vin) 24V 5A (21.6~33.6Vin) DDR-120B-48 INPUT: 16.8~33.6VDC 9A OUTPUT: 48V 2.3A (16.8~21.6Vin) 48V 2.5A (21.6~33.6Vin) DDR-120C-12 INPUT: 33.6~67.2VDC 4.5A OUTPUT: 12V 9A (33.6~43.2Vin) 12V 10A (43.2~67.2Vin) DDR-120C-24 INPUT: 33.6~67.2VDC 4.5A OUTPUT: 24V 4.5A (33.6~43.2Vin) 24V 5A (43.2~67.2Vin) DDR-120C-48 INPUT: 33.6~67.2VDC 4.5A OUTPUT: 48V 2.3A (33.6~43.2Vin) 48V 2.5A (43.2~67.2Vin) DDR-120D-12 INPUT: 67.2~154VDC 2.5A OUTPUT: 12V 9A (67.2~86.4Vin) 12V 10A (86.4~154Vin) DDR-120D-24 INPUT: 67.2~154VDC 2.5A OUTPUT: 24V 4.5A (67.2~86.4Vin) 24V 5A (86.4~154Vin) DDR-120D-48 INPUT: 67.2~154VDC 2.5A OUTPUT: 48V 2.3A (67.2~86.4Vin) 48V 2.5A (86.4~154Vin) DDR-240B-24 INPUT: 16.8~33.6VDC 13.5A OUTPUT: 24V 8A (16.8~21.6Vin) DDR-240B-48 24V 10A (21.6~33.6Vin) INPUT: 16.8~33.6VDC 13.5A OUTPUT: 48V 4A (16.8~21.6Vin) 48V 5A (21.6~33.6Vin) DDR-240C-24 INPUT: 33.6~67.2VDC 7.5A OUTPUT: 24V 9A (33.6~43.2Vin) 24V 10A (43.2~67.2Vin) DDR-240C-48 INPUT: 33.6~67.2VDC 7.5A OUTPUT: 48V 4.5A (33.6~43.2Vin) 48V 5A (43.2~67.2Vin) DDR-240D-24 INPUT: 67.2~154VDC 3.7A OUTPUT: 24V 9A (67.2~86.4Vin) 24V 10A (86.4~154Vin) DDR-240D-48 INPUT: 67.2~154VDC 3.7A OUTPUT: 48V 4.5A (67.2~86.4Vin) 48V 5A (86.4~154Vin)
2 Introduction DDR series is a DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, ultra slim width, 2:1 wide input voltage, fanless design, -40~+70 wide operating temperature, 4kVdc I/O isolation, 150% peak load, current sharing, DC OK, adjustable output voltage and full protective functions. This series of models has various input options: 9~18V / 16.8~33.6V / 33.6~67.2V / 67.2~154V and various output options: 12V / 24V / 48V and can be used for industrial & railway control, security control, communication system and other fields. Suitable applications include DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable...etc. Installation (1)Always allow good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit in use to prevent it from overheating. Also a cm clearance must be kept when the adjacent device is a heat source. (2)The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on the top. Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is not allowed. (3)Use copper wire only, and recommended wires are shown as below. AWG Rated Current of Equipment (Amp) 7A 10A 15A 20A 30A Cross-section of Lead(mm 2 ) Note: 1. Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. 2. The maximum allowable wire cross-sectional area for the terminal of the SDR-75 is 12AWG/2.5 mm 2. Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact. If the power supply possesses multi-output terminals, please make sure each contact is connected to wires to prevent too much current stress on a single contact. (4)Use wires that can withstand temperatures of at least 80 C, such as UL1007. (5)Recommended wire strapping length is 5mm (0.197 ). (6)Recommended screwdriver is 4mm, slotted type. (7)The recommended torque setting for terminals is shown as below. Model I/P O/P DDR kgf-cm (6 Lb-in) 6.9 kgf-cm (6 Lb-in) DDR kgf-cm (7 Lb-in) 5.13 kgf-cm (4.45 Lb-in)
3 (8)Suggested fuse is shown as below. Model Fuse DDR-120A DDR-120B DDR-120C DDR-120D DDR-240B DDR-240C DDR-240D T10A/L250V x2 T8A/L250V x2 T8A/L250V x1 T4A/L250V x1 T10A/L250V x2 T6.3A/L250V x2 T6.3A/L250V x1 (9)Mounting Instruction: Mount as shown in figure only, with input terminals down, or else sufficient cooling will not be possible. Admissible DIN rail:ts35/7.5 or TS35/15 For rail fastening: (a)tilt the unit slightly rearwards. (b)fit the unit over top hat rail. (c)slide it downward until it hits the stop. (d)press against the bottom for locking. (e)shake the unit slightly to check the locking action "Click" (10)For other information about the products, please refer to for details. Warning / Caution!! (1)Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do not remove the case of the power supply by yourself! (2)Risk of electric arcs and electric shock (danger to life). Connecting both the primary and the secondary sides together is not allowed. (3)Risk of burn hazard. Do not touch the unit in operation and shortly after disconnection! (4)Risk of fire and short circuit. The openings should be protected from foreign objects or dripping liquids. (5)Only install the unit in a pollution degree 2 environment (Note.1). (6)Please do not install the unit in places with high moisture or near the water. (7)The maximum operating temperature is 55 C for DDR-120 series, please do not install the unit in places with high ambient temperature or near fire source. (8)The FG ( ) must be connected to PE (Protective Earth). (9)Output current and output wattage must not exceed the rated value on its specification. (10)Disconnect system from supply voltage: Before commencing any installation, maintenance or modification work: Disconnect your system from supply voltage. Make sure that inadvertent connection in circuit will be impossible!
4 (11)For continued protection against risk of fire, replace only with same type and rating of fuse. Pour ne pas compromettre la protection contre les risqué d incendie, remplacer par un fusible de même type et de memes caractéristiques nominales. Note.1: Pollution Degree 2 applies where there is only non-conductive pollution that might temporarily become conductive due to occasional condensation. Generally refer to dry, well-ventilated locations, such as control cabinets. Manufacturer: MEAN WELL ENTERPRISES Co., LTD. No.28, Wuquan 3rd Rd., Wugu Dist., New Taipei City 24891, Taiwan Tel: Web: Branch Office: China MEAN WELL (GUANGZHOU) ENTERPRISES Co., LTD. 2F, A Building, Yuean lndustry Park, Huangcun,Dongpu Yown, Tianhe District, Gungzhou, China Post Code: Tel: Web: U.S.A. MEAN WELL USA, INC Fremont Blvd., Fremont, CA 94538, U.S.A. Tel: Web: Europe MEAN WELL EUROPE B.V. Langs de Werf 8, 1185XT Amstelveen, The Netherlands Tel: Web:
5 Declaration of China RoHS Conformity In order to reduce the impacts on the environment and take the more responsibility for protecting the earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products. Environment Friendly Use Period Label Observing SJT , Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products Observing SJ/Z , General Guidelines of Environment-friendly Use Period of Electronic Information Products Appendix B, adopting table look-up to verify the Environment Friendly Use Period Names and Contents of Hazardous Substances Lists Part Name PCB and its components Metal structure parts Plastic structure parts Lead (Pb) Mercury (Hg) Cadmium (Cd) Hazardous Substances Hexavalent chromium (Cr 6+ ) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) X O X O O O X O O O O O O O O O O O Accessories O O O O O O Cables X O O O O O O: The concentration of the hazardous substances within the homogeneous material of that product is less than the concentration limits set by GB/T X: The concentration of the hazardous substances within the homogeneous material of that product is over the concentration limits set by GB/T ; however, it follows the standard advised by 2011/65/EU.
PFC Function / Metal Case PFC Function / Plastic Case Plastic Case. PCB Type
60 30 30 18 30 ~ 240W ~ 96 W ~ 60 W ~ 60 W ~ 60 W CLG PLN ELN LP PLP series series series series series - PFC Function / Metal Case PFC Function / Plastic Case Plastic Case Plastic Case PCB Type About
More informationRosemount 405 Compact Primary Element. Quick Start Guide , Rev HA June 2016
Rosemount 405 Compact Primary Element 00825-0100-4810, Rev HA NOTICE This guide provides basic guidelines for Rosemount 405. It does not provide instructions for configuration, diagnostics, maintenance,
More informationRX 3 MCB 4500 A Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationTechnical Report No D Dated
Client: Innokin Technology Co.,Ltd Address: Attn.: Building 6,XinXinTian Industrial Park, XinSha Road, ShaJing street,shenzhen, China George Sample Description: itaste 134 MX-M Model No.: / Contury of
More informationDIN Rail Power Supply. AC/DC Switching Power Supplies
DIN Rail Power Supply AC/DC Switching Power Supplies Company Profile Established in 1982, MEAN WELL is a leading standard switching power supply manufacturers in the world. MEAN WELL currently operates
More informationMCF3 DC86V11CT Inrush-withstand
RoHS Pb Dimensions and construction: (mm) Case: Cover: Terminal substrate metal: Terminal primary plating: Terminal surface plating: Adhesive: Marking: Ceramic Ceramic Copper t=0.1 mm Nickel plated copper,
More informationTube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu. Pb87.5-Sn10-Ag2.5* ma less than 1 A.
* 1 RoHS Dimensions and construction: Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu (mm) Marking: Pb87.5-Sn10-Ag2.5* 1 100 ma less than 1 A 1 A 15 A SOC [rated current]
More informationLead-free glass Nickel plated brass Ceramic 100 ma 15 A. Tube: End-cap: Core: Solder: 200 A. Marking: 100 ma 8 A Over 8 A 20 A. Rated breaking current
* RoHS Dimensions and construction: (mm) Tube: End-cap: Core: Solder: Marking: Lead-free glass Nickel plated brass Ceramic 100 ma 15 A 20 A 100 ma 8 A Over 8 A 20 A Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* Pb90-Cu*
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationLead-free glass Nickel plated brass Ceramic Tin plated copper Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* SOC NSD9 D32V [rated current]
* RoHS Dimensions and construction: (mm) Tube: End-cap: Core: Lead wire: Solder: Marking: Lead-free glass Nickel plated brass Ceramic Tin plated copper Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* SOC NSD9 D32V [rated
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationMCF3 25CT Inrush-withstand
RoHS Pb Dimensions and construction: (mm) Case: End-cap substrate metal: End-cap primary plating: End-cap surface plating: Adhesive: Marking: Ceramic Copper t=0.25 mm Nickel plated, 0.5 μm or more Tin
More informationLead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A. Tube: End-cap: Solder: Adhesive: Marking: 1 A 3 A
RoHS Pb Dimensions and construction: (mm) Tube: End-cap: Solder: Adhesive: Marking: Lead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A 1 A 3 A Sn-0.7Cu Sn-3.0Ag-0.5Cu
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationTechnical Report No C Dated
Client: Innokin Technology Co.,Ltd Address: Attn.: Building 6, XinXinTian Industrial park, Xinsha Road Shajing, Baoan District, Shenzhen, China George Description: COOL FIRE IV Model No.: / Country of
More informationDX³ RCCBs - ID 4P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationTechnical Report No Rev. 00 Dated
Technical Report No. 64.164.14.01453.01 Rev. 00 Dated 2014-05-28 Client: ZhongShan LiangYi Lighting CO.,LTD BeiHai Industrial Zone,GuZhen Town,ZhongShan,GuangDong,P.R.China Test Subject: The submitted
More informationSafety Standards. Model Number:
Highlights & Features RoHS Compliant Relay alarm indirection Built-in 2 channel DC OK signal Caused by rugged handing Conformal coating on PCBA to protect against chemical and dust pollutants Class I,
More informationOPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1
OPERATIONS MANUAL M-520 Please take the time to read these instructions before starting to use the scales Page 1 Contents Power supply 3 Specifications 3 Maintenance and general care 3 Key functions 4
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationTX³ RCCBs 2P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationTechnical Report No A Dated
Client: Xiamen Guangpu Electronics Co.,Ltd. Address: No.608, West Lingdou Road, Siming District, Xiamen, China. Attn.: Mr. Zheng Description: LED Panel Light Model No.: GPP0330934WP,GPP0330934WPB Country
More informationSign Panel Power Supply
High Performance Slim Design Sign Panel Power Supply 150W~500W AC/DC LED Display Switching Power Supplies & Company Profile Established in 1982, MEAN WELL is a leading standard switching power supply manufacturers
More informationDRB-1 Series Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
More informationTechnical Report No A Dated
Client: Innokin Technology Co.,Ltd Address: Attn.: Building 6, XinXinTian Industrial park, Xinsha Road Shajing, Baoan District, Shenzhen, China George Description: itaste MVP 3.0 Pro Model No.: / Country
More informationDRL-1 Series Instruction Manual
DRL-1 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit
More informationup to 63 A (1 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationRX 3 M.C.B A up to 63 A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 RX 3 M.C.B. 6000 A up to 63 A Cat. N (s): 4 197 49 to 4 199 23 CONTENTS PAGES 1. Description, use... 1 2. Range... 1 3. Overall dimensions...
More informationTechnical Report No B Dated
Client: Innokin Technology Co.,Ltd Address: Attn.: Building6,XinXinTian Industrialpark, Xinsha Road, Shajing, Baoan District, Shenhen, China P.R.C. George Description: itaste VV4 Model No.: / Contury of
More informationFeatures. Isolation PFM. Block Diagram
Features SMT Technology 2:1 Input Range Efficiency up to 85 I/O Isolation 00 Remote on/off Control Short Circuit Protection MTBF > 1,000,000 Hours RoHS Compliant MSL2 (Moisture Sensitivity Level) per IPC/JEDEC
More informationFeatures. Figure 1. Block Diagram. Figure 2. Input - Output DC Voltage
Features CBAM PQ-28 The Power Quality Module (PQ-28) is a single input power conditioning module 1/2 brick package (2.28 x 2.4 x 0.50 ) Designed for 200 Watts Designed to interface with MIL-STD-1275B,
More informationDX³ 4-pole RCBO 6000 A/10 ka
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationTechnical Report No A Dated
Client: Xiamen Guangpu Electronics Co.,Ltd Address: No.608,West Lingdou Road,Siming District,Xiamen,China. Attn.: Mr. Zhang Description: Panel light (LED PANEL LIGHT) Model No.: Country of origin: GPPS15033X,
More informationDX³ RCBO 4500/6 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationSHENZHEN TIMEWAY TESTING LABORATORIES
Report No: File reference No: TW1609018 2016-09-08 Applicant: Product: Model No: Brand Name: Test Conclusions: Fold Cable MO8887 N/A Based on the verification results of the submitted samples, the test
More informationAmendment to legal inspection regulations of automotive video cameras, other audio-frequency electric amplifiers and head-mounted monitors
Amendment to legal inspection regulations of automotive video cameras, other audio-frequency electric amplifiers and head-mounted monits By the Bureau of Standards, Metrology and Inspection (BSMI), Ministry
More informationRestriction of the use of certain hazardous substances (RoHS) Summary Report
JJ Electronic S.R.O A. Hlinku 4 022 01 Čadca Slovak Republic Restriction of the use of certain hazardous substances (RoHS) Summary Report Test of: Vacuum Tube Model Number: EL34 Unique Identifier: None
More informationDC Master 24/ A
USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015
More information- PFC Function / Metal Case. - PFC Function / Economical Metal Case. - PFC Function / Plastic Case. - PFC Function / Plastic Case
96 ~240W 60 ~ 150W 60 ~ 96 W 20 ~ 96 W 30 ~ 96 W 30 ~ 60 W 18 ~ 60 W 20 ~ 60 W 150W HLG series CLG series CEN series PLN series PLC series ELN series LP series PLP series ULP series - High Efficiency with
More informationContact: Customer Service Phone: Fax: esales.electrocube.com Website:
Supplier: Electrocube, Inc., 3366 Pomona Blvd., Pomona, California 91768 Contact: Customer Service Phone: 909-595-4037 Fax: 909-595-0186 Email: esales..com Website: www..com Date: 01/02/13 Quality Assurance
More informationUZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.
BATTERY MODULE Two Mounting Options: DIN-Rail or Panel/ Wall Mounting IP00 Open Type Protection Level Easy Access to the Terminals and the Fuse Heavy Duty Fuse Holder and Spare Fuse Included UZK12.071
More informationTEST REPORT. Version:V1.0 Page 1 of 9. Client company : Berdis Lighting Co., LTD.
TEST REPORT Client company : Berdis Lighting Co., LTD. Client address : 6F, No.1, South 2nd Lane, HuaTai East Road, Caosan Industrial Park, Guzhen Town, Zhongshan City, Guangdong Province, China Report
More informationDX³ RCBO 6000 A Phase + Neutral, neutral right side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1
More informationUZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.
PASSIVE BATTERY MODULE Two Mounting Options: DIN-Rail or panel/wall mounting IP00 Open Type Protection Level Easy Access to the Terminals and the Fuse Heavy Duty Fuse Holder and Spare Fuse Included 1.
More informationTYPE EDL Electric Double Layer Supercapacitors
TYPE EDL Electric Double Layer Supercapacitors Ultra High Capacitance, Small Case Size Options RoHS Compliant Type EDL electric double layer supercapacitors offer extremely high capacitance values (farads)
More informationRoHS-Compliant. Watertight, Dust-Resistant Motors FPW Series
RoHS-Compliant Watertight, Dust-Resistant s FPW Series 1 RoHS-Compliant Watertight, Dust-Resistant s FPW Series Induction Type The FPW Series are geared motors which conform to the IEC standard IP67 (Recognized
More informationDISCONTINUED CONTACT KEMET FOR EQUIVALENT REPLACEMENT
Dipped, Radial Leaded, Solid Tantalum Capacitors Specifications Capacitance Range: Voltage Range: Tolerance: Operating Temperature Range: DC Leakage: Capacitance Change imum: Reverse Voltage (Non-continuous):
More informationQuick Start Guide , Rev FB June Rosemount 485 Annubar Flanged Flo-Tap Assembly
Quick Start Guide 00825-000-809, Rev FB Rosemount 85 Annubar Flanged Flo-Tap Assembly Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 85 Annubar. It does not provide instructions
More informationTechnical Report No A Dated
Client: Aquil Star Precision Industrail (Shenzhen) Co., Ltd Address: Attn.: Building A and B, The No. 4 Of Tengfeng Thrid Road, Fenghuang Third Industry, Fuyong Town, Baoan Zone, Shenzhen City, P.R. China.
More informationType TDL Solid Tantalum Capacitors
Dipped, Radial Leaded, Solid Tantalum Capacitors Specifications Capacitance Range: Voltage Range: Tolerance: Operating Temperature Range: The Type TDL, like the Type TDC, is a low cost alternative to molded
More informationCertificate of Compliance of RoHS
270 Quaker Road East Aurora, NY 14052 Certificate of Compliance of RoHS This document certifies that the API Delevan part numbers identified and manufactured by API Delevan do not contain the substances
More informationDX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 / 10 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationRP Instruction Manual
Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.
More informationQuick Start Guide , Rev AB June Rosemount 585 Annubar Flanged Assembly
Quick Start Guide 00825-0100-585, Rev AB Rosemount 585 Annubar Flanged Assembly Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 585 Annubar Assembly. It does not provide instructions
More information27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2
1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:
More informationBtdin-RS RCBO 2p Phase + Neutral, neutral on right
Viale Borri 231, 21100 Varese - Italy RCBO 2p CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1 5. General characteristics... 2 6. Compliance
More informationEVS RP6020. Instruction Manual
Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.
More informationUZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.
BATTERY MODULE Long Life Battery: 10 to 12 Years According to EUROBAT Small Mounting Footprint Easy Access to the Terminals and the Fuse Heavy Duty Fuse Holder and Spare Fuse Included 3 Year Warranty,
More informationUS Series Single-Phase 110/115 VAC Single-Phase 220/230 VAC
RoHS-Compliant Speed Control Motor and Control Unit Package US Series Single-Phase 11/11 VAC Single-Phase 22/23 VAC RoHS-Compliant Speed Control Motor and Control Unit Package US Series Single-Phase 11/11
More informationUZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS
BATTERY MODULE 24V, 7Ah Battery Capacity (2x 12V Batteries in Series) Small Mounting Footprint 2m Power Leads Included PT1000 Sensor for Battery Module Temperature Included Includes a Center-tap Terminal
More informationLS200 Series Instruction Manual
LS200 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage may lead to an electrical shock, damage to the unit
More informationDX³ RCBO 6000A Phase + Neutral, neutral on left
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationValveMate 7000 Controller Operating Manual
A NORDSON COMPANY ValveMate 7000 Controller Operating Manual Steady Test Clear Time Set Fast Slow POWER RUN SETUP CYCLE A NORDSON COMPANY VALVEMATE 7000 Run Setup Purge Program Fast Slow Time Set Pressure
More informationApproved: Date : Customer acceptance. Lithium Manganese Dioxide Battery CR2450. Typed : Date : Checked : Date : Approved : Customer admit signature:
Customer acceptance Lithium Manganese Dioxide Battery CR2450 Typed : Date : Checked : Date : Approved: Date : Customer admit signature: Approved : Date : 1. Scope These specifications are applicable to
More informationPP017/PP018 Passive Probe Instruction Manual
PP017/PP018 Passive Probe Instruction Manual 700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000, Fax: (845) 578 5985 www.teledynelecroy.com PP017/PP018 Passive Probe Instruction
More informationVolant NEA/NEF010 Series
Features: Small size, minimal footprint/low profile 10A Output Current (all voltages) High Efficiency: up to 95% High reliability RoHS Compliant Cost efficient open frame design Pre-bias monotonic start-up
More informationUZK24.121, UZO GENERAL DESCRIPTION 2. DATA 4. MARKINGS 3. ORDER NUMBERS
PASSIVE BATTERY MODULE 24V, 12Ah Battery Capacity (2x 12V Batteries in Series) IP00 Open Type Protection Level Small Mounting Footprint ATO Fuse for Power Wires Included 2m Power Leads Included PT1000
More informationRosemount 3095FC MultiVariable Mass Flow Transmitter
Quick Start Guide 00825-0100-4832, Rev CA Rosemount 3095FC MultiVariable Mass Flow Transmitter with Modbus Protocol Quick Start Guide NOTICE This guide provides basic guidelines for the Rosemount 3095FC
More informationDX³ RCBO 6000A Phase + Neutral, neutral on right
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 6000A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationGVB-8 (Boost) Manual
GVB-8 (Boost) Manual Solar Charge Controllers with Maximum Power Point Tracking For models: GVB-8-Pb-12V: 12V Lead-Acid/AGM/Gel/Sealed/Flooded GVB-8-Pb-24V: GVB-8-Pb-36V: GVB-8-Pb-48V: GVB-8-Pb-CV: 24V
More informationTest Report. TIANJIN TOYO INK CO.,LTD.. 12XINGHUA2#ROAD XIQING ECONOMIC DEVELOPMENT AREA,TIANJIN , CHINA.
Test Report. No. TSNEC1500174842 A01 Date: 05 Mar 2015. Page 1 of 8. TIANJIN TOYO INK CO.,LTD.. 12XINGHUA2#ROAD XIQING ECONOMIC DEVELOPMENT AREA,TIANJIN 300385, CHINA. This report is to supersede test
More information9GV612G01 6x6x28 mm 12 V GV type Expected Life: 40,000 h (L10:Survival rate: 90% at 60 C, Tach output G speed : + red - black Sensor yellow Storage Temperature: -20 C to +70 C (Non-condensing) 9GV612G01
More informationVersion:V1.0 Page 2 of 17
Results: A. EU RoHS Directive 2011/65/EU and its amendment directives on XRF Test method: With reference to IEC 62321-3-1:2013, Screening by X-ray Fluorescence Spectroscopy (XRF) Seq. No. A Tested Part(s)
More informationTEST REPORT Test Report # 17A E Date of Report Issue: April 24, 2017 Date of Sample Received: April 14, 2017 Pages: Page 1 of 8
TEST REPORT Test Report # Date of Report Issue: April 24, 2017 Date of Sample Received: April 14, 2017 Pages: Page 1 of 8 CLIENT INFORMATION: Company: Address: Mid Ocean Brands B.V. Unit 201, 2/F, Laford
More information- PFC Function / Metal Case. - PFC Function / Economical Metal Case. - PFC Function / Plastic Case. - PFC Function / Plastic Case
96 ~240W 60 ~ 150 W 60 ~ 9 6 W 20 ~ 96 W 30 ~ 96 W 30 ~ 60 W 18 ~ 100 W 20 ~ 60 W 150W HLG series CLG series CEN series PLN series PLC series ELN series LP series PLP series ULP series - High Efficiency
More informationManual ZEBRA 15 Release:
Manual ZEBRA 15 Release: 15.07.2015 A Table of Contents A Table of Contents... 2 B ZEBRA Function... 3 B 1 ZEBRA Benefits... 4 B 2 ZEBRA Applications... 5 B 3 ZEBRA Amortization (ROI)... 6 C Safety...
More informationdv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING
dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.
More informationCGA Series Automotive Grade Capacitors
CGA Series Automotive Grade Capacitors Type: CGA2 [EIA CC0402] CGA3 [EIA CC0603] CGA4 [EIA CC0805] CGA5 [EIA CC1206] CGA6 [EIA CC1210] Issue date: April 2011 TDK MLCC US Catalog REMINDERS Please read before
More informationUser Manual. Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5
More informationZWD225PAF Series Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
More informationEZS. Motorized Linear Slides. Series. RoHS-Compliant
RoHS-Compliant Motorized Linear Slides EZS Series AUDIN -, avenue de la malle - 5137 Saint Brice Courcelles - Tel : 3...1 - Fax : 3... - Web : http: www.audin.fr - Email : info@audin.fr RoHS-Compliant
More informationTest Report No. C Date: Sep 14, 2016 Page 1 of 11
Test Report No. C160907030003 Date: Sep 14, 2016 Page 1 of 11 Dragino Technology Co., Limited Room 7009, Zi'An Commercial Building, Qian Jin 1 Road. Xin'An 6th District, Bao'an District ; Shenzhen 518101,China
More informationL Charger. Instruction manual
L 1039-10 Charger Instruction manual Contents Contents Contents... 1 Important safety instructions... 2 Package contents... 3 The L 1039-10 charger... 3 Product overview... 4 Putting the charger into operation...
More informationEGQ 212: Duct transducer, CO 2 and temperature
Product data sheet 7.0 EGQ : Duct transducer, CO and temperature How energy efficiency is improved Measuring the CO concentration and temperature for energy-efficient, demand-controlled regulation of the
More informationVSM480. Instruction Manual VARIABLE SPEED MIXER. Read instructions before operating this tool.
VSM480 VARIABLE SPEED MIXER Instruction Manual Read instructions before operating this tool. Important Please read these operating and safety instructions carefully and completely. For your own safety,
More informationBattery chargers. Technical addendum.
BP Battery chargers Technical addendum www.cretechnology.com www.cretechnology.com BPxxxx 9 0020 B EN technical addendum www.cretechnology.com Content 1 Common features...6 1.1 Mounting...6 1.2 Definitions...7
More informationChapter 1. Structure and Features
Chapter 1 Structure and Features CONTENTS Page 1 History of IGBT structure 1-2 2 Module structure 1-4 3 Circuit configuration of IGBT module 1-5 4 Overcurrent limiting feature 1-6 5 RoHS compliance 1-6
More information3M Mini D Ribbon (MDR) Cable Assembly.050 High Speed Video Data Transmission System, 50 Position 14X50-SZWB-XXX-0NC
(MDR) Assembly Supports LVDS Channel Link signaling 20 shielded pairs (100 ohm) +4 drains for high bandwidth applications High density 50 position MDR with rugged ribbon type contact 3 Unshielded Twisted
More informationNo. HKGEC Date: 13 Oct 2017 Page 1 of 10
No. HKGEC1700775405 Date: 13 Oct 2017 Page 1 of 10 RUBADUE WIRE CO.,INC. 1301 NORTH 17TH AVE, GREELEY, CO 80631, GREELEY 80631 UNITED STATES.. The following sample(s) was/were submitted and identified
More informationSpecifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W
2019-V1.0-0318 Specifications AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W No. 545 Museum Road Yangzhou, Jiangsu China 225009 Tel: 86 (514) 8279 1592 Fax: 86 (514) 8769 3159 2019 AC-DC Din Rail
More informationQ-CELLS CIGS THIN FILM MODULES: HIGHEST EFFICIENCY IN THE MARKET
Q-CELLS CIGS THIN FILM MODULES: HIGHEST EFFICIENCY IN THE MARKET Votum Workshop, Prague, May 13, 2010 DISTRIBUTION LIST: WORK-SHOP PARTICIPANTS CONTENTS Q-CELLS CIGS MODULES: POWER, QUALITY AND AESTHETICS
More informationR820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017
R80 REV SERIES SCR POWER CONTROLS NOVEMBER 017 Product overview The Viconics R80 series SCR power controls are designed for cost effective, precise modulation of electric loads for most electric heating
More informationZWD100PAF Series Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
More informationCustomer Specification PART NO. V16110
Alpha Wire 711 Lidgerwood Avenue, Elizabeth, NJ 07207 Tel: 1-800-52 ALPHA (25742), Web: www.alphawire.com Customer Specification PART NO. V16110 Construction Diameters (In) 1) Component 1 4 X 1 COND a)
More information720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet
for industrial applications Product Data Sheet 720 W / 24 V On-board Battery Charger for industrial applications Features IP65 protection degree Battery selection via GUI, supporting all leading battery
More informationRT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide
RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input 208-240 Vac Output 208-120 Vac User Guide UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY
More informationUser Manual Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...
More information