PRODUCT MANUAL ENGINE PROTECTION SYSTEM PANEL 4-FUNCTION WATER COOLED VERSION 2. Part No. 9200

Size: px
Start display at page:

Download "PRODUCT MANUAL ENGINE PROTECTION SYSTEM PANEL 4-FUNCTION WATER COOLED VERSION 2. Part No. 9200"

Transcription

1 PRODUCT MANUAL ENGINE PROTECTION SYSTEM PANEL -FUNCTION WATER COOLED VERSION Part No. 900

2 DISCLAIMER Copyright Remote Control Technologies Pty Ltd (RCT) All rights reserved. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the written permission of Remote Control Technologies Pty Ltd. (RCT). Information provided in this manual is intended to be accurate and reliable. However, Remote Control Technologies Pty Ltd (RCT) assumes no responsibility for its use or infringements upon the rights of third parties that may result from its use. All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Remote Control Technologies Pty Ltd (RCT) will accept no responsibility for actual use of the product based on these illustrative examples. Please contact your nearest Remote Control Technologies Pty Ltd (RCT) branch for more information concerning applications in life critical situations or high reliability. Remote Control Technologies Pty Ltd (RCT) reserves the right to make changes to any product herein to improve reliability, function or design. All specifications are subject to change without notice. M088a.docx Rev. Modified on 08/0/05 Copyright RCT

3 Contents CAUTION. CONSULT THE SPECIFICATIONS DATA SHEET ON PAGE Error! Bookmark not defined. PRIOR TO THE INSTALLATION OF THE PRODUCT. INCORRECT FITMENT WILL VOID THE MANUFACTURER S WARRANTY. GENERAL SAFETY WARNINGS 5 PRODUCT OVERVIEW 6 FEATURES AND FUNCTIONS 6 OPERATION AND USE 7 CONTROL UNIT 7 WIRING CONNECTIONS 7 INPUTS 7 OUTPUTS 8 INSTALLATION GUIDE 9 CONTROL UNIT 9 AUDIBLE ALARM 9 COOLANT LEVEL SENSOR FUNCTION 0 ENGINE OIL PRESSURE SWITCH FUNCTION 0 ENGINE TEMPERATURE SWITCH FUNCTION OIL/FUEL LEVEL SWITCH FUNCTION LOW ENGINE OIL LEVEL SWITCH LOCATION DIAGRAM (59D) ENGINE PROTECTION SYSTEM LABELLING ALERT FUNCTION IDENTIFICATION LABELS TYPICAL ENGINE PROTECTION SYSTEM SCHEMATIC TO SUIT -FUNCTION WATER COOLED ENGINES (90x) 5 CALIBRATION 6 SERVICE INFORMATION 6 SERVICE SCHEDULE 6 SERVICE PROCEDURE 6 COOLANT LEVEL SENSOR 6 ENGINE OIL PRESSURE SWITCH 6 ENGINE TEMPERATURE SWITCH 6 OIL/FUEL LEVEL SWITCH 6 TEST PROCEDURE 7 CONTROL UNIT 7 COOLANT LEVEL SENSOR 7 ENGINE OIL PRESSURE SWITCH 7 ENGINE TEMPERATURE SWITCH 8 OIL/FUEL LEVEL SWITCH 8 PARTS LIST 8 DECALS SUPPLIED WITH THE PRODUCT 8 WIRING LOOMS TO SUIT 900 CONTROL UNIT 8 COOLANT LEVEL SENSORS 8 PRESSURE SWITCHES TO SUIT ENGINE OIL PRESSURE APPLICATIONS 9 TEMPERATURE SWITCHES TO SUIT TEMPERATURE MONITORING APPLICATIONS 9 OIL/FUEL LEVEL SWITCHES TO SUIT OIL LEVEL MONITORING APPLICATIONS 9 M088a.docx Rev. Modified on 08/0/05 Copyright RCT

4 ALARMS TO SUIT THE WARNING ALERT FUNCTION OF THE CONTROL UNIT 9 TECHNICAL SPECIFICATIONS 0 COMPLIANCE AND STANDARDS TROUBLESHOOTING GLOSSARY WARRANTY APPENDIX ETR IDLE TIMER / EPS / FIRE CONTROL UNIT DIAGRAM (78i) M088a.docx Rev. Modified on 08/0/05 Copyright RCT

5 GENERAL SAFETY WARNINGS PERSONAL SAFETY Everyone is responsible for safety. The installer/service personnel should be trained and authorized to complete the required work. Ensure that the machine is safely isolated during installation and testing to protect all personnel. Complete all required risk assessments and job safety analysis (JSA) before commencing work. Observe all site specific and machine OEM procedures regarding the following: working at heights working in heat working in confined spaces all other site specific occupational health and safety (OH&S) procedures MACHINE Carry out all prestart operations as per site and machine OEM procedures. Ensure the machine is safely isolated during installation and testing to protect the machine and other equipment in the area. Do not operate any machine with a known fault and report all findings to the supervisor in writing. Test and operate machine as per machine OEM and site procedures. Read and understand machine and site specific operational and testing instructions. PRODUCT Before applying power to the equipment, the user/repairer/ installer must read all product instructions. If in doubt, seek assistance. Ensure electrical connections are made as per RCT s recommendations. Test circuits prior to connecting power to any component. The equipment contains no user serviceable parts inside. Return the unit to RCT for repairs. Retain product and installation instructions for future use. Ensure that RCT s recommended service procedures are included in the machine s service routine. Observe all machine, site and RCT product warnings. Follow all machine, site and RCT product operating procedures at all time. The application of safety should not be limited to the above recommendations. M088a.docx Rev. Modified on 08/0/05 Copyright RCT 5

6 PRODUCT OVERVIEW The Muirhead Engine Protection system (EPS), part number 900, is designed to monitor almost any alarm condition on virtually any machine. This system has been designed to monitor four inputs including an AC input for detecting coolant loss and three digital outputs. The system continuously monitors four areas of protection and alerts the operator of abnormal engine conditions. With no mechanical parts, the EPS control unit is extremely reliable, easy to install and simple to use. Every EPS control unit can be customised to monitor known problems and functions commonly associated with equipment failure. Note: Additional looms, fittings, switches, lights and audible alarm may be required to perform a complete installation. FEATURES AND FUNCTIONS Multi-voltage (8 to volts) Alarm only, return to idle/shutdown modes System test function Custom fault indicator labelling Configurable inputs Reduces downtime Substantially reduces the risk of engine failure Simple installation Audio/visual indicators Individual fault indicators Compact and robust control panel design Extends machine life Multiple applications IP65 enclosure 6 M088a.docx Rev. Modified on 08/0/05 Copyright RCT

7 OPERATION AND USE CONTROL UNIT Electronic circuitry within the EPS control unit monitors the state of the switches and sensors, and then activates the corresponding alert indicator and control outputs when an alarm condition is sensed. The EPS label displays the alert indicator or function that has faulted. A test switch located on the front of the EPS control unit allows the operator to simulate a fault and test the complete system. A connector with contacts located on the rear of the EPS control unit facilitates the necessary wiring for the inputs and outputs. ALERT INDICATORS TEST SWITCH -PIN CONNECTOR WIRING CONNECTIONS No. FUNCTION TYPE +8 V DC to +0 V DC Ignition supply 0 V DC ground Ground Output Alarm control Output Idle control 5 Output Energised to run control (ETR) 6 Input Start input 7 Function AC circuit/switch input 8 Function Switch input 9 Function Switch input 0 Function Switch input Not used Not used Not used Not used INPUTS The following input functions indicate the factory defaults with all inputs and outputs being configurable. Refer to document number P00 for advanced programming information. Contact your local RCT branch or distributor for a copy of the document or for more information. FUNCTION This input is configured to have a five-second delay prior to pulsing the alert indicator and activating the alarm. After a further 0 seconds, the alert indicator will come on solid, the alarm will remain on and activate the idle and ETR control circuits. This circuit activates when the circuit changes state and becomes open. This input is specifically designed for coolant level detection. If this function is not required, pin 7 must be connected to ground. Note: This function uses an AC (alternating current) circuit. This reduces electrolysis and corrosion of the coolant level sensor. This will assist to keep the probe in good working order. M088a.docx Rev. Modified on 08/0/05 Copyright RCT 7

8 FUNCTION This input is configured to have a one-second delay prior to activating the corresponding alert indicator, external audible alarm, idle and ETR control circuits. This circuit activates when the circuit changes state and becomes open. If this function is not required, pin 8 must be connected to ground. Typical use: Low engine oil pressure FUNCTION This input is configured to have a one-second delay prior to activating the corresponding alert indicator, external audible alarm, idle and ETR control circuits. This circuit activates when the circuit changes state and becomes open. If this function is not required, pin 9 must be connected to ground. Typical use: High engine temperature FUNCTION This input is configured to have a one-second delay prior to activating the corresponding alert indicator, external audible alarm, idle and ETR control circuits. This circuit activates when the circuit changes state and becomes open. If this function is not required, pin 0 must be connected to ground. Typical use: Low engine oil level or transmission temperature OUTPUTS ALARM CONTROL OUTPUT This circuit is activated as soon as an alert indicator is active. This output remains active until the EPS control unit has no alert indicator active or the key is switched off. This output is disabled until a start signal is sensed. This allows servicing to be carried out with the key ON without the alarm sounding. IDLE CONTROL This circuit operates as a direct opposite to the alarm control output. It switches off when the alarm control output is active. This output is used in conjunction with additional control systems that return the engine to idle when an alert indicator is activated. If return to idle is not required, this circuit should not be connected. ENGINE CONTROL (ETR) This circuit operates in a similar way to the idle control output; however, it has a 0 to 0-second adjustable time delay. This time delay is factory set to 0 seconds, allowing the machine to run for 0 seconds after an alert indicator has been activated. This circuit is an energised to run output. This output also incorporates an automatic system override circuit which allows the EPS control unit to override the engine oil pressure switch allowing the engine to be started. If shutdown is not required, this circuit should not be connected. WARNING! When an alert indicator is active, special care should be taken to assess safety considerations which may arise from shutting the machine down.. Will the machine be left uncontrollable, as shutdown affects the braking and steering of most machines?. Can the machine be parked in a safe environment? 8 M088a.docx Rev. Modified on 08/0/05 Copyright RCT

9 INSTALLATION GUIDE Note: If the EPS system is installed in conjunction with an idle timer and/or a fire status control unit, it is imperative that the units are installed in the correct order. Failure to do so may result in the machine not shutting down correctly. Refer to the appendix at the end of this manual for the correct sequence. CONTROL UNIT. The recommended location for the control unit is in the operator s cabin in clear view and within easy reach of the operator. Proximity to the operator is important as the control unit incorporates a system test switch/circuitry that allows service personnel and/or operators to test the system.. Drill two 8 mm diameter holes with the hole centres being 00 mm apart to suit the M8*0 hex screw that bolts to the control unit mounting bracket. Careful consideration should be given to the location of these holes before drilling to ensure adequate accessibility to the electrical connection located on the rear of the control unit.. Refer to the wiring table below and the wiring diagram in this manual to wire up the control unit. It is recommended that the wiring loom be installed alongside the OEM engine wiring ensuring that it is secured at regular intervals; this will provide protection from heat and abrasion, and any other excess damage that may occur with extended machine operation. When securing the loom to the OEM engine wiring, ensure that the loom is away from moving machine parts which could lead to loom damage.. Install the sensors/ switches (see below for more detail). All sensors/ switches should be installed using a suitable thread sealant. Note: RCT recommends that all electrical connections be treated with electroguard grease (part number 800). Options If a Muirhead Idle Timer is fitted, the machine will return to idle immediately. If a Muirhead Shutdown Control unit is fitted, the machine will return to idle for the specified time and then shutdown. Notes Perform a system test using the test procedure in the Calibration section in this manual. For information on testing individual functions and/or parts of the EPS system, refer to the additional testing information in this manual. AUDIBLE ALARM There are three ways of mounting the audible warning alarm;. Through instrument panel (via a 9 mm hole). Via an optional mounting bracket (part number 9655). Under the instrument panel (cable tied to loom) M088a.docx Rev. Modified on 08/0/05 Copyright RCT 9

10 COOLANT LEVEL SENSOR FUNCTION It is recommended that the coolant level sensor be installed in the radiator tank (refer to the details below). Ensure there is sufficient clearance within the radiator to accommodate the length of the coolant. Drill the required hole size in the tank and tap to the required thread size as specified below. Always clean debris away and remove any foreign objects before installing the probe. Fit the coolant level sensor and pressure test, this can be achieved by running the engine until normal operating temperature has been reached. PROBE POSITION OPTIMUM PROBE LEVE IS ⅓ UP FROM THE BOTTOM OF THE TOP HOSE HOLE Part No. 006 Thread: /8 NPT Nylon Tapping drill: /6 Probe length: 0 mm Part No. 887 Thread: / NPT Nylon Tapping drill: 7/6 Probe length: 7 mm Note: Brass weld collar included RADIATOR Installation Example Part No. 05 Thread: / NPT Brass Probe length: 60 mm Tapping drill: 7/6 ENGINE OIL PRESSURE SWITCH FUNCTION The engine oil pressure switch should be located in a suitable oil gallery access port. Use the original equipment manufacturer (OEM) oil pressure switch as a guide for location. Fit the oil pressure switch using thread sealant, being careful not to over tighten. Note: T-pieces are available in most thread types to enable both the OEM and Muirhead Oil Pressure Switches to be installed into the original port. Part No. 008 PSI Normally Open Thread: /8 NPT Part No PSI Normally Open Thread: /8 NPT Part No PSI Normally Open Thread: /8 NPT Part No PSI Normally Open Thread: 9/6 UNO Part No. 9 6 PSI Normally Open Thread: /8 NPT Part No. 0 9 PSI / 6 kpa Normally Open Thread: /8 NPT 0 M088a.docx Rev. Modified on 08/0/05 Copyright RCT

11 ENGINE TEMPERATURE SWITCH FUNCTION The coolant temperature switch should be installed on the engine side of the thermostat control. It is imperative that the switch sensing area (bulb) be immersed in coolant. Install the switch using thread sealant. Note: Care should be taken when selecting a mounting port to allow sufficient depth for the bulb. Part No. 76 F / 00 C Normally Closed Thread: /8 NPT Part No F / 0 C Normally Closed Thread: /8 NPT Part No F / 0 C Normally Closed Thread: /8 NPT Part No. 89 Heavy Duty Temp Switch 5 F / 07 C Normally Closed Thread: /8 UNO OIL/FUEL LEVEL SWITCH FUNCTION The oil/fuel level switch is a capacitive type switch with a ¼ NPT mounting thread and used to monitor levels in tanks and reservoirs. The switch should be installed at the low level mark which is specified by the OEM. Ensure there is sufficient clearance within the tank so as not to interfere with the switch installation. Install switch using thread sealant. Note: Care should be taken when selecting a mounting position as the maximum allowable ambient temperature for the switch is 00 C. Also note that the oil/fuel level switch incorporates a three-second alarm delay. For operating temperatures above 00 C, installing the 8690 heavy duty switch is recommended. Part No. 07 Normally Open Thread: / NPT brass Tapping drill: 7/6 Part No Normally Open (Heavy Duty) M088a.docx Rev. Modified on 08/0/05 Copyright RCT

12 LOW ENGINE OIL LEVEL SWITCH LOCATION DIAGRAM (59D) REV ZONE DESCRIPTION BY DATE new titleblock GT 6/07/07 rewrite step 5 BT 5/07/07 A I updated titleblock POINT REWORDED GT 0/08/5 MT 7/08/5 A B INSTALLATION DETAILS ENGINE FRONT VIEW B C C D D E 5 SLIDE UP OR DOWN TO DESIRED LEVEL E SWITCH POINT MUST LINE UP WITH LOW LEVEL IN SUMP F OIL PAN MOUNT SWITCH ON A BRACKET CLOSE TO OR ON ENGINE F G G H I FITTING INSTRUCTIONS. DRAIN ENOUGH OIL UNTIL THE DIPSTICK MARK IS ON LOW WITH THE ENGINE RUNNING AT NORMAL SPEED.. TEMPORARILY INSTALL A LENGTH OF CLEAR PLASTIC TUBING FROM THE LOWER OIL PAN AND RETURN TO THE UPPER PAN.. OIL LEVEL SIGHTED BY EYE ACROSS PLASTIC TUBE TO SIDE OF OIL PAN. THIS LEVEL DETERMINES THE LOCATION OF LOW OIL SWITCH POINT. ALL DIMENSIONS IN MILLIMETERS UNCONTROLLED DOCUMENT SCALE NTS rd ANGLE PROJECTION A COPYRIGHT - ALL RIGHTS RESERVED This drawing is the property of REMOTE CONTROL TECHNOLOGIES PTY LTD (RCT), and is not to be copied or used in whole or in part for any purpose without the express authority of RCT. The drawing is to be returned to RCT, on demand. H I J. BRAISE " NPT FITTING IN THE SIDE OF THE PAN. INSTALL HOSE FITTING ADAPTOR - USE TEFLON TAPE TO SEAL THE THREADS. 5. THE MULTI LEVEL SWITCH MUST BE PLUMBED SO THAT THE LOWER HOSE PORT IS LOWER THAN THE LOW LEVEL SWITCH POINT AND THE TOP HOSE PORT MUST BE PLUMBED SO THAT IT IS HIGHER THAN THE LOW LEVEL SWITCH POINT. LOW ENGINE OIL LEVEL SENSOR LOCATION FITTING INSTRUCTIONS J K K PART NO 8690 STOCK MULTI LEVEL SWITCH CODE BY JL DRN RH DATE //0 APPD JL DATE ---- L SHEET of STATUS DWG No Released 59d 8 REV L M088a.docx Rev. Modified on 08/0/05 Copyright RCT

13 ENGINE PROTECTION SYSTEM LABELLING WATER COOLED There are a wide range of decals available and also blank decals which can be used when not all four functions are required. The engine protection system incorporates a simple but effective labelling system that can be customised to suit individual needs. The construction of the label is a simple process;. Select the correct decal that is required for the application.. Remove the adhesive backing from the decal and place in the correct clear insert on the main label. Make sure the decal is aligned correctly (as shown in the above diagram).. Use a plastic card or similar tool to carefully push any air bubbles that form out to the edges of the label.. Once all the decals that are required have been placed in their correct clear inserts on the main label, remove the adhesive backing from the main label and fit it onto the engine protection control enclosure. 5. Remove all air bubbles and clean the label. The labelling process is now complete. M088a.docx Rev. Modified on 08/0/05 Copyright RCT

14 ALERT FUNCTION IDENTIFICATION LABELS PART NO. LABEL PART NO. LABEL M088a.docx Rev. Modified on 08/0/05 Copyright RCT

15 TYPICAL ENGINE PROTECTION SYSTEM SCHEMATIC TO SUIT -FUNCTION WATER COOLED ENGINES (90x) REV ZONE DESCRIPTION BY DATE Pins re-ordered C MT /09/5 A A B B C D 8-0V SUPPLY GROUND ALARM IDLE CONTROL ETR CONTROL 5 START INPUT 6 COOLANT LEVEL 7 OIL PRESSURE 8 ENGINE TEMP 9 OIL LEVEL 0 NOT USED NOT USED ENGINE PROTECTION SYSTEM CONTROL OR- BK- GN- BN- YL/BU- PU- WH- PK- YL- GY- GN- BK- BN- + BK FAULT ALARM CAUTION! OUTPUT CURRENT RATING AMP MAX IDLE CONTROL SOLENOID CAUTION! OUTPUT CURRENT RATING AMP MAX C D E F NOTE THIS IS A TYPICAL ENGINE PROTECTION SYSTEM SCHEMATIC ILLUSTRATING ALL INPUTS AND OUTPUTS. THIS SHOULD ONLY BE USED AS A GUIDE AS DIFFERENT MACHINES REQUIRE DIFFERENT COMPONENTS. FOR MORE INFORMATION PLEASE CONTACT THE MANUFACTURER. YL/BU- + BK- - WH- GROUND VIA COOLANT TO TANK L ETR RUN SOLENOID CAUTION! OUTPUT CURRENT RATING AMP MAX COOLANT LEVEL PROBE E F NOTE PK- G IF NOT ALL FUNCTIONS ARE REQUIRED, A BLANK LABEL IS PLACED ON THE UNUSED FUNCTION AND THE CORRESPONDING INPUT WIRE MUST BE CONNECTED TO GROUND. BK- YL- N/O P OIL PRESSURE SWITCH G H BK- N/C T ENGINE TEMPERATURE SWITCH H I 8-0VDC PROTECTED SUPPLY (RECOMMENDED 0AMP PROTECTION) TO START TERMINAL AT KEY SWITCH RD- GY- BK- MACHINE (FRAME) GROUND C A B + S - OIL LEVEL SWITCH ALL DIMENSIONS IN MILLIMETERS UNCONTROLLED DOCUMENT SCALE NTS rd ANGLE PROJECTION A COPYRIGHT - ALL RIGHTS RESERVED This drawing is the property of REMOTE CONTROL TECHNOLOGIES PTY LTD (RCT), and is not to be copied or used in whole or in part for any purpose without the express authority of RCT. The drawing is to be returned to RCT, on demand. I J J PANEL EPS FUNCTION WATER COOLED VER EXTERNAL WIRING K K WIRE LEGEND BK - BLACK PK - PINK BU - BLUE PU - PURPLE L BN - BROWN RD - RED GN - GREEN WH - WHITE GY - GREY YL - YELLOW OR - ORANGE TQ - TURQUOISE M088a.docx Rev. Modified on 08/0/05 Copyright RCT PART NO 900 STOCK MH-EPS--0 CODE BY SD DRN GT DATE 08/0/0 APPD SD DATE ---- SHEET of STATUS DWG No Released 90x 8 REV L

16 CALIBRATION Not applicable SERVICE INFORMATION SERVICE SCHEDULE The manufacturer recommends that the following service procedure should be performed at each machine s scheduled service interval. SERVICE PROCEDURE. Perform a visual inspection and include the following: a) Control unit b) Wiring connections and looms c) All switches and sensors as below d) Engine fluids. Perform a system test as per the following: a) Refer to the Operation and Use section of this manual for the operation of the control unit and each function. b) Test each circuit individually as per the Test Procedure. Note: All monitoring switches should be changed when fitting a new or repaired engine to a machine. COOLANT LEVEL SENSOR Every 000 hours or six months. Remove the sensor from the radiator.. Plug the hole to minimise coolant loss.. Inspect the condition of the sensor ensuring the centre of the sensor is insulated from outer mounting. Ensure the sensor is free from grease, oil and dirt.. Inspect electrical connection point for thread damage, burrs, corrosion and ensure the nut tightens on the thread (if applicable). 5. Refit the sensor ensuring the thread is free from coolant leaks. ENGINE OIL PRESSURE SWITCH Every 000 hours or six months. If engine oil faults are present and tests performed on the electrical circuit prove inconclusive, it is recommended that the engine oil pressure switch be replaced.. Due to the critical function of this switch, it is recommended that the engine oil pressure switch be replaced every 000 hours or every six months. ENGINE TEMPERATURE SWITCH Every 000 hours or six months. If temperature faults are present and tests performed on the electrical circuit prove inconclusive, it is recommended that the coolant temperature switch be replaced.. Due to the critical function of this switch, it is recommended that the coolant temperature switch be replaced every 000 hours or every six months. OIL/FUEL LEVEL SWITCH Every 000 hours or six months. It will be necessary to remove the switch for testing.. Remove switch and plug hole to prevent fluid loss.. Inspect the switch for physical damage.. Reconnect the -pin Deutsch plug. 5. Turn the ignition switch to the ON position. 6. Verify the oil/fuel level alert indicator is now illuminated. 7. Immerse the threaded end of the switch in oil and verify that the oil/fuel level alert indicator is no longer illuminated. 8. If the switch tests okay, refit the switch using thread sealant. 6 M088a.docx Rev. Modified on 08/0/05 Copyright RCT

17 TEST PROCEDURE The testing of the EPS control unit should ideally be performed when the operator first checks the machine at the beginning of each shift or when the machine is due for its scheduled service. The testing of the engine protection control unit incorporates a system test switch, this allows the service person and/or operator to easily test the EPS control unit. In order to test the EPS control unit, the following test procedure should be followed. System Test Switch CONTROL UNIT. Start and run the machine as per normal (raise the RPM above idle if the idle control function is used). All alert indicators on the control unit should light up and activate the alarm on initial start-up, and cease immediately once the control unit has detected that the engine oil pressure has been pressurised.. If the control unit has detected a fault upon start-up, for example, if the machine coolant level is low, the fault will be present on the control unit upon start-up of the machine.. Press and hold the control unit test switch, all alert indicators on the control unit should illuminate immediately and the alarm control circuit will activate, sounding the alarm.. Having depressed the system test switch for 0 seconds, the engine ETR output will turn off, shutting down the engine if the engine shutdown option of the control unit is being utilised. If the shutdown option is not being used, the machine will return to idle when an alert indicator is activated. 5. Once the system test switch has been released, the EPS system will return the machine to its normal operation so that the machine can be restarted and returned to normal operation if machine shutdown has occurred. Note: The 0-second period is adjustable. System Fault Procedure 6. If the test procedure has been performed and the system has not functioned as per above, report the malfunction to the supervisor before operating the machine. 7. Should any fault (visual or audible) be detected while operating the machine or if the engine RPM drops below its normal operating level, the machine should be parked safely ensuring the park brake is applied. The engine should then be shut down, and the malfunction reported to the supervisor. COOLANT LEVEL SENSOR Every 50 hours or during machine scheduled service. Turn the ignition switch to the ON position and verify the coolant level alert indicator is not illuminated.. Disconnect the wire from the coolant level sensor.. Verify that the coolant level alert indicator is now illuminated.. Reconnect the wire to the coolant level sensor. 5. Remove sufficient coolant from the engine to allow the level to fall below the sensor probe. 6. Verify that the coolant level alert indicator is illuminated. 7. Refill coolant to the manufacturer s specifications. 8. Check that the coolant level alert indicator is no longer illuminated. 9. Turn the ignition off. ENGINE OIL PRESSURE SWITCH Every 50 hours or during machine scheduled service. Turn the ignition switch to the ON position.. Verify that the fault alarm is sounding and the oil pressure alert indicator is illuminated.. Bridge the wires at the oil pressure switch.. Verify that alarming has ceased and the oil pressure alert indicator is no longer illuminated. 5. Remove bridging connector. 6. Start and run machine until engine oil pressure reaches normal operating pressure. 7. Verify that alarming has ceased and the oil pressure alert indicator is no longer illuminated. M088a.docx Rev. Modified on 08/0/05 Copyright RCT 7

18 ENGINE TEMPERATURE SWITCH Every 50 hours or six months. Turn the ignition switch to the ON position.. Check that the engine temperature alert indicator is not illuminated.. Disconnect one wire at the engine temperature switch.. Verify that the engine temperature alert indicator is now illuminated. 5. Turn the ignition off and reconnect electrical wiring. OIL/FUEL LEVEL SWITCH Every 50 hours or during machine scheduled service. Turn the ignition switch to the ON position.. Check that the oil level alert indicator is not illuminated.. Disconnect the -pin Deutsch plug at the level switch.. Verify that the oil level alert indicator is now illuminated. 5. Turn the ignition off and reconnect electrical wiring. PARTS LIST PART NO. DESCRIPTION 900 EPS -Function Water Cooled Control unit DECALS SUPPLIED WITH THE PRODUCT PART NO. DESCRIPTION QTY 565 Coolant Level Label 56 Oil Level Label 567 Oil Pressure Label 568 Engine Temperature Label 07 Blank with Red Dot Label The following sensors and switches are NOT supplied with the control unit as there may be a particular type of switch and/or sensor required to suit a particular type of machine for the application that it is needed for. WIRING LOOMS TO SUIT 900 CONTROL UNIT PART NO. DESCRIPTION 8797 Loom 5 m To Suit 90 & 900 EPS Control unit 8805 Loom 0 m To Suit 90 & 900 EPS Control unit COOLANT LEVEL SENSORS PART NO. DESCRIPTION 006 Coolant level sensor Light Duty /8 NPT (Plastic Body) 887 Coolant level sensor Light Duty / NPT (Complete with Brass Bush) 05 Coolant level sensor Heavy Duty / NPT (Brass Body) 8 M088a.docx Rev. Modified on 08/0/05 Copyright RCT

19 PRESSURE SWITCHES TO SUIT ENGINE OIL PRESSURE APPLICATIONS PART NO. DESCRIPTION 008 Pressure Switch 9 PSI /8 NPT, N/O 07 Pressure Switch 8 PSI, Terminal, N/O, /8 NPT (Light Duty) 875 Pressure Switch 8 PSI, Terminal, N/O, /8 NPT (Heavy Duty) 9976 Pressure Switch PSI, Sure-Seal Connection, 9/6 UNO 7968 O-ring Seal To Suit 9976 Pressure Switch (Recommended) 9 Pressure Switch 6 PSI Falling, N/O, /8 NPT 0 Pressure Switch 9 PSI Falling, N/O, /8 NPT TEMPERATURE SWITCHES TO SUIT TEMPERATURE MONITORING APPLICATIONS PART NO. DESCRIPTION 76 Temperature Switch F, N/C, Terminal /8 NPT 765 Temperature Switch 0 F, N/C, Terminal /8 NPT 766 Temperature Switch 0 F, N/C, Terminal /8 NPT 767 Temperature Switch 50 F, N/C, Terminal /8 NPT 768 Temperature Switch 75 F, N/C, Terminal /8 NPT 89 Temperature Switch 5 F, N/C, Terminal, O-ring, / UNO 79 Adaptor Bush /8 NPT Female to / NPT Male To Suit /8 NPT Temperature Switches OIL/FUEL LEVEL SWITCHES TO SUIT OIL LEVEL MONITORING APPLICATIONS PART NO. DESCRIPTION 07 Oil Level Switch Capacitive, N/O, / NPT, Used For Temperatures Below 00 C 8690 Oil Level Switch (Heavy Duty), N/O, Multilevel Switch is Recommended for Applications That Exceed 5 C ALARMS TO SUIT THE WARNING ALERT FUNCTION OF THE CONTROL UNIT PART NO. DESCRIPTION 7 Warning Alarm, Constant or Intermittent Siren / V 66 Warning Alarm, 0 db / V Heavy Duty Note: The sensors and switches listed in this manual are only a small selection available from RCT. If a sensor is required for a specific application, please contact your local RCT branch or distributor; alternatively, sales@rct.net.au. M088a.docx Rev. Modified on 08/0/05 Copyright RCT 9

20 TECHNICAL SPECIFICATIONS CAUTION! PLEASE READ CAREFULLY PRIOR TO THE INSTALLATION OF THE PRODUCT. INCORRECT FITMENT WILL VOID THE MANUFACTURER S WARRANTY. Dimensions, control unit only Dimensions, boxed for freight Weight, control unit only Weight, including harness / packaging for freight Input nominal voltage Length: 5 mm Width: 0 mm Height/Depth: 80 mm Length: 0 mm Width: 0 mm Height/Depth: 70 mm 0.65 kg 0.85 kg to V Operating temperate range 0 to 70 C Connection types Inputs Min & max input voltage Circuit protection Enclosure type Environmental protection IP rating Programming/adjustment -pin Deutsch receptacle Ignition, ground switches and sensors 8 to V DC Reverse polarity protected, outputs are current overload protected Aluminium powder coated IP65 Refer to document number P00 ADDITIONAL SPECIFICATIONS Power Supply Supply spike withstand Absolute maximum spike (J) 50 A (8/0 µs pulse) event 00 A / 50 µs, 8 A / ms 0 events 0 A / 50 µs, A / ms 00 events 0 A / 50 µs, A / ms 000 events 5 A / 50 µs,.5 A / ms Inputs Spiked supply voltage 00 V 00 ms 00 V 0 ms 00 V ms Outputs Current rating Inrush current rating Maximum 6 A continuously Maximum 0 A Note:. Outputs have protection incorporated to protect from installation error causing shorted outputs.. Outputs are current overload protected. 0 M088a.docx Rev. Modified on 08/0/05 Copyright RCT

21 COMPLIANCE AND STANDARDS TBA TROUBLESHOOTING Troubleshooting the engine protection system requires additional information from the manual that is supplied with the Muirhead EPS system. As a guide, a typical engine protection schematic is provided in this manual. During troubleshooting, inspect all components and connectors before any components are replaced. If connectors are not tight and clean they can cause intermittent or permanent electrical faults. Ensure the connectors are tight and clean before any other tests are carried out. Failure of an electrical component can cause, or be caused by the failure of one or more other components. Always attempt to find and correct the cause of the engine protection system failure before replacing a component. Tools needed: Part no. 005 Digital Multimeter x Part no Circuit Tester x Digital Multimeter Use the part number 005 digital multimeter or equivalent for making continuity checks and voltage measurements. It is recommended that the circuit tester, part number 7599 or equivalent only, be used to test the three outputs of the EPS control unit. Note: If the EPS system is being installed in conjunction with an idle timer and/or a fire status control unit, it is imperative that the units are installed in the correct order. Failure to do so may result in the machine not shutting down correctly. Refer to the appendix at the end of this manual for the correct sequence.. M088a.docx Rev. Modified on 08/0/05 Copyright RCT

22 GLOSSARY A Amp (Ampere) N/A Not Applicable AC Alternating Current N/C Normally Closed AMS Advanced Management System N/O Normally Open CAN Controller Area Network OEM Original Equipment Manufacturer CMIO Control Master Input Output PCB O/P Outputs CMR Control Master Receiver Out Output CMT Control Master Transmitter PB Push Button CM00 Control Master 00 Remote Set PC Personal Computer COMMS Communications PCB Printed Circuit Board CPU Central Processor Unit PIN Personal Identification Number DC Direct Current PLC Programmable Logic Controller E.G. For example POT Potentiometer FET Field Effect Transistor PPM Pulses Per Metre GND Ground PWM Pulse Width Modulation H Hours PWR Power HEX Hexidecimal Numbering System RCT Remote Control Technologies Pty Ltd ID Identity Rev Revision i.e That is RF Radio Frequency In Input RH Relative Humidity IP Ingress Protection RPM Revolutions per minute kg Kilogram RX Receiver Recommended Standard (number ) Km/h Kilometres Per Hour RS for serial data transfer LCD Liquid Crystal Display SYS System LED Light Emitting Diode TOV Text On Video LK Link TX Transmitter M Minutes V Volts ma Milli Amps VSC Variable Spray Controller MAX Maximum WSC Water Spray Controller MCU Multi Control Unit C Degrees Centigrade MFU Multi Function Unit # Number Mega Hertz (million(s) cycles per MHz second) < Less Than MIN Minimum > Greater Than mm millimetres % Percentage mw Milli Watts WARRANTY Please see the RCT standard warranty, available on our website - M088a.docx Rev. Modified on 08/0/05 Copyright RCT

23 PROTECTION SYSTEMS APPENDIX ETR IDLE TIMER / EPS / FIRE CONTROL UNIT DIAGRAM (78i) REV ZONE DESCRIPTION BY DATE Reordered wiries, L-J7, removed glands and MT 6// H5 wiring from EPS and replaced 7650 with 588, A THE FIRE CONTROLLER RED WIRE CAN BE CONNECTED TO THE ORANGE WIRE OF THE PRESSURE SWITCH TERMINAL TO AVOID THE FIRE CONTROLLER TIMING OUT AFTER SIX (6) SECONDS WHEN THE IGNITION IS SWITCHED OFF. A B RD- PU- YL/BU- RD- PU- OR- BR OR PU YL B S C R NOTE. FOR OFF HIGHWAY TRUCKS (OHT) AND OTHER MACHINES THAT USE THE C TERMINAL OF THE IGNITION SWITCH; B ENSURE THAT BOTH "AUX CONTROL" WIRES FROM THE CONTROLLERS ARE CONNECTED AS SHOWN. NOTE THAT THE C TERMINAL IS DISCONNECTED FROM THE KEY SWITCH WHEN AUX CONTROL WIRE IS USED AS SHOWN BELOW. C TO MACHINE RD- PU- YL/BU- RD- OR- BR OR PU YL B S C R C D E NOTE. WHERE THE YELLOW / BLUE AND ORANGE WIRES JOIN, USE A PIN DEUTSCH PLUG TO MAKE THIS CONNECTION. NOTE. THE IGNITION SWITCH CONNECTIONS ARE MADE BY USING DEUTSCH PLUGS TO INTERFACE DIRECTLY INTO THE CATERPILLAR IGNITION SWITCH CONNECTOR PLUG. NOTE. THE IDLE TIMER, EPS AND FIRE CONTROLLER MUST BE CONNECTED IN THE ORDER AS SHOWN, TO FACILITATE CORRECT SHUTDOWN PRIORITY SEQUENCE. NOTE 5. A DIODE IS INSTALLED AS INDICATED WHEN AN EPS SYSTEM IS INSTALLED. D E AUX CONTROL PU ! IDLE TIMER 50 7 N596 F OR- 6 5 F YL/BU- BK- RD- IDLE TIMER CONTROLLER (50) G G OR- BK- H YL/BU- PU- 5 6 COOLANT LEVEL OIL PRESSURE H 7 ENGINE TEMP I OIL LEVEL WARNING Machine may return to idle or shutdown on fault EPS (565)(77) (900)(90) SYSTEM TEST ALL DIMENSIONS IN MILLIMETERS UNCONTROLLED DOCUMENT SCALE NTS A rd ANGLE PROJECTION COPYRIGHT - ALL RIGHTS RESERVED This drawing is the property of REMOTE CONTROL TECHNOLOGIES PTY LTD (RCT), and is not to be copied or used in whole or in part for any purpose without the express authority of RCT. The drawing is to be returned to RCT, on demand. I J K AUX CONTROL RD- YL/BU- PU- OR- BK POWER ON / CYLINDER PRESSURE OK SYSTEM FAULT / CYLINDER PRESSURE LOW SYSTEM DISCHARGE / ENGINE SHUTDOWN WARNING WHEN FIRE UNIT IS ACTIVATED SIREN WILL OPERATE AND ENGINE WILL SHUT DOWN AFTER TIME DELAY FIRE STATUS PANEL PANEL TEST SHOT O'RIDE SHUTDOWN BYPASS ENERGISED TO RUN (ETR) IDLE TIMER (50)/EPS/FIRE CONTROLLER CIRCUIT TO SUIT CATERPILLAR MACHINES EXTERNAL WIRING J K FIRE CONTROL (588) PART NO ---- STOCK CODE ---- BY EY DRN CW DATE /05/ APPD DAS DATE /05/ L SHEET of STATUS Work in Progress DWG No 78i 8 REV L M088a.docx Rev. Modified on 08/0/05 Copyright RCT

24 PERTH Unit -5/5 Abernethy Road Kewdale WA 605 Ph: +6 (0) Fax: +6 (0) BRISBANE Unit 6/6 Flinders Parade North Lakes QLD 509 Ph: +6 (0) Fax: +6 (0) KALGOORLIE Percy Road Kalgoorlie WA 60 Ph: +6 (0) Fax: +6 (0) MT ISA A Ryan Road Mt Isa QLD 85 Ph: +6 (0) Fax: +6 (0) MELBOURNE Unit Hallmarc Office Park 5 Ricketts Road Mt Waverley VIC 9 Ph: +6 (0) Fax: +6 (0) AFRICA: +7 (0) NORTH AMERICA: RUSSIA/CIS: +7 (90) -7 SOUTH AMERICA:

PRODUCT MANUAL LIGHT VEHICLE ENGINE PROTECTION SYSTEM. Part No. 3206

PRODUCT MANUAL LIGHT VEHICLE ENGINE PROTECTION SYSTEM. Part No. 3206 PRODUCT MANUAL LIGHT VEHICLE ENGINE PROTECTION SYSTEM Part No. 3206 DISCLAIMER Copyright Remote Control Technologies Pty Ltd (RCT) All rights reserved. No part of this manual may be reproduced, copied,

More information

PRODUCT MANUAL ENGINE PROTECTION SYSTEM 6-FUNCTION TO SUIT AIR COOLED ENGINES. Part No. 3747

PRODUCT MANUAL ENGINE PROTECTION SYSTEM 6-FUNCTION TO SUIT AIR COOLED ENGINES. Part No. 3747 PRODUCT MANUAL ENGINE PROTECTION SYSTEM 6-FUNCTION TO SUIT AIR COOLED ENGINES Part No. 77 DISCLAIMER Copyright Remote Control Technologies Pty Ltd (RCT) All rights reserved. No part of this manual may

More information

PRODUCT MANUAL PARK BRAKE WARNING SYSTEM 12/24 VOLTS. Part No

PRODUCT MANUAL PARK BRAKE WARNING SYSTEM 12/24 VOLTS. Part No PRODUCT MANUAL PARK BRAKE WARNING SYSTEM 12/24 VOLTS Part No. 11377 11386 11387 DISCLAIMER Copyright Remote Control Technologies Pty Ltd (RCT) All rights reserved. No part of this manual may be reproduced,

More information

PRODUCT MANUAL FUEL CAP ISOLATION SYSTEM. Part No

PRODUCT MANUAL FUEL CAP ISOLATION SYSTEM. Part No PRODUCT MANUAL FUEL CAP ISOLATION SYSTEM Part No. 78 06 7808 DISCLAIMER Copyright Remote Control Technologies Pty Ltd (RCT) All rights reserved. No part of this manual may be reproduced, copied, translated,

More information

CRITICAL SPARES GUARD LASER MURPHY RECOMMENDED PARTS 30%OFF ** GAUGES FATIGUE WARNING KIT NOW $ 10%OFF * 15%OFF * keep your fleet moving

CRITICAL SPARES GUARD LASER MURPHY RECOMMENDED PARTS 30%OFF ** GAUGES FATIGUE WARNING KIT NOW $ 10%OFF * 15%OFF * keep your fleet moving CRITICAL SPARES RECOMMENDED PARTS keep your fleet moving 30%OFF ** MURPHY GAUGES RELIABLE. PRECISE. DURABLE. LONG-LASTING. Big discount for our wide selection of Murphy gauges for your industry. Part No:

More information

SECTION MH 2. MH 1

SECTION MH 2.   MH 1 SECTION 2 Manufactured by: PERTH Unit 2-5/511 Abernethy Road Kewdale Western Australia 6105 Ph: +61 8 9353 6577 Fax: +61 8 9353 6578 KALGOORLIE 24 Percy Road Kalgoorlie Western Australia 6430 Ph: +61 8

More information

PREVENT INCIDENTS REFUELLING DUAL FUEL CAP ISOLATION SYSTEM. Control & Automation Protection Systems

PREVENT INCIDENTS REFUELLING DUAL FUEL CAP ISOLATION SYSTEM. Control & Automation Protection Systems 2 Control & Automation Protection Systems Information Systems PREVENT REFUELLING INCIDENTS DUAL FUEL CAP ISOLATION SYSTEM The Muirhead Dual Fuel Cap Isolation system is the latest in the range of Smart

More information

IVTM Installation Manual

IVTM Installation Manual Integrated Vehicle Tire Pressure Monitoring IVTM Installation Manual 2nd edition Copyright WABCO 2006 Vehicle Control Systems An American Standard Company The right of amendment is reserved Version 002/06.06(us)

More information

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 1 27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2 STX2401-C STX2401-T FEATURES 0843-CPR-0213 14 Elmdene International Ltd Tel: +44(0)23 9269 6638 3 Keel Close, Interchange Park, Fax:

More information

DESIGNED TO SUIT YOUR MARKET

DESIGNED TO SUIT YOUR MARKET DESIGNED TO SUIT YOUR MARKET INDUSTRIAL PARTS SOLUTION rct-global.com 2 CONTENTS Overview 4 LED Compact Work Lamp 5 Forklift LED Warning Lamp 6 Forklift LED Line Light 7 Colour Change LED Mini Light Bar

More information

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...

More information

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA MDCKB1-120081-01 110VAC, 8A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories Murphy W-Series Engine Panels General Installation Instructions WS-93002N Revised 04-06 Section 30 (00-02-0191) Read the following information before installing. These installation instructions are typical

More information

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit R Vehicle Security INSTALLATION MANUAL Model: PLUS-4700 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference;

More information

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine Introduction An ISO 9001:2008 Registered Company ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown 2014-2016 Isuzu NPR 6.0L Gasoline Engine Contact InterMotive for additional vehicle applications

More information

Technical Description

Technical Description Technical Description LUL, 73 Stock Refurbishment Heating, Ventilating & Air-conditioning Multi-stage Thermostat for Saloon 0.1 19-May-02 ISSUED FOR DISCUSSION FK DC Rev. Date Description By Check Copyright

More information

Power Distribution System User s Manual. Model: PDS-100

Power Distribution System User s Manual. Model: PDS-100 Power Distribution System User s Manual Model: PDS-0 Section Page Product Overview... 1 I) General Information... 2 II) Important Safety Information... 2 III) Installation... 3 A) Materials Provided...

More information

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range Silvertel V1.3 October 2009 Datasheet Intelligent Pb 1 Features Multi-Stage Charging Battery Reversal Protection Reduced Power Consumption Wide DC or AC Input Voltage Range High Efficiency DC-DC Converter

More information

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories

WARNING. Murphy W-Series Engine Panels General Installation Instructions. Installation Accessories Murphy W-Series Engine Panels General Installation Instructions WS-93002N Revised 08-02 Section 30 (00-02-0191) Read the following information before installing. These installation instructions are typical

More information

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications An ISO 9001:2008 Registered Company System Operation Idle Timer Controller - ITC805 2013-2018 Freightliner MT45 Contact InterMotive for additional vehicle applications The ITC805 system shuts down idling

More information

Gen INSTALLATION MANUAL

Gen INSTALLATION MANUAL Gen 2 INSTALLATION MANUAL READ THIS FIRST Installation of this system should be carried out by qualified persons familiar with the general installation of law enforcement electronics commonly installed

More information

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer. Sprayer Control Plumbing & Installation Manual for SprayLink Cable Installations Tank Jet Tank Shut-Off Diaphragm Pump Electric Ball s Transducer Strainer Relief Regulating Copyrights 2012 TeeJet Technologies.

More information

Timer Relays - Fixed & Adjustable

Timer Relays - Fixed & Adjustable Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE710 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44

More information

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White. MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM H7/1 Green : (-) 200mA Pulse H7 3 Pin H7/3 Blue : (-) 200mA Unlock White LED Indicator Valet Switch H6 2 Pin

More information

B21 Series BASOTROL Gas Valve

B21 Series BASOTROL Gas Valve Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully

More information

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA MDCKB1-120081 120VAC, 8A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

Cover. L5v2 Plug-In Conversion Module(PCM) Diagnostic Trouble Codes

Cover. L5v2 Plug-In Conversion Module(PCM) Diagnostic Trouble Codes Cover L5v2 Plug-In Conversion Module(PCM) Diagnostic Trouble Codes Copyright 2009 A123 Systems, Inc. All rights reserved DOCUMENT NOTICE: The information contained in this manual is the property of A123

More information

Installation Instructions for: Channel Thermocouple Amplifier

Installation Instructions for: Channel Thermocouple Amplifier Installation Instructions for: 30-2204 4 Channel Thermocouple Amplifier WARNING: This installation is not fo r the electrically or mechanically challenged! Use this sensor with EXTREME caution! If you

More information

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY EXHAUST BRAKES C40019 1999-2003 FORD F250 / F350 7.3L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY Getting Started Thank you and congratulations on your purchase of a Pacbrake exhaust retarder.

More information

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL. TPM 001 Revision 0.1

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL. TPM 001 Revision 0.1 TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL Revision 0.1 3 TD80 and Overfill Prevention System Troubleshooting Equipment Required: 1. Automotive Test light, 6VDC to 24VDC 2. Short length

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE4120 AUTO MAINS FAILURE MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel:

More information

Installation and Operating Instructions. Solar System Controller ISC3020

Installation and Operating Instructions. Solar System Controller ISC3020 Installation and Operating Instructions Solar System Controller ISC3020 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s of

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE720 AUTOSTART CONTROL MODULE OPERATING MANUAL http://bestgenerator.spb.ru/?page_id=6765 Deep Sea Electronics Plc Highfield House Hunmanby North

More information

-2- Designed to automatically operate a diesel fire pump engine when the contacts of a remote water pressure switch close.

-2- Designed to automatically operate a diesel fire pump engine when the contacts of a remote water pressure switch close. -1-1 -2- FUNCTION Designed to automatically operate a diesel fire pump engine when the contacts of a remote water pressure switch close. POWER SUPPLY: 240V A.C single phase supply and 12 or 24 V D.C. INDICATORS:

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING: WARNING: www.altronicinc.com DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO LEAD IMPROPER TO IMPROPER OP- ERATION OF ENGINE THE MACHINE

More information

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100 Document Number: XE-TCA1PM-R0A TCA100 Rev0511 PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100 FIRE RESEARCH CORPORATION www.fireresearch.com 26 Southern Blvd., Nesconset,

More information

LCD EWP /FAN DIGITAL CONTROLLER Installation Instructions

LCD EWP /FAN DIGITAL CONTROLLER Installation Instructions 77 Taras Avenue P.O. Box 363 Altona North Vic 3025 Australia Phone: +61(0)3 9369 1234 Fax: +61(0)3 9369 3456 Email: info@daviescraig.com.au Web: www.daviescraig.com.au LCD EWP /FAN DIGITAL CONTROLLER Installation

More information

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range Silvertel V1.1 October 2012 Pb 1 Features Multi-Stage Charging Battery Reversal Protection Reduced Power Consumption Wide DC or AC Input Voltage Range High Efficiency DC-DC Converter Programmable Charge

More information

Installation and Operating Instructions. Solar System Controller ISC3030

Installation and Operating Instructions. Solar System Controller ISC3030 Installation and Operating Instructions Solar System Controller ISC3030 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s of the

More information

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down DC-DC Converter has a digitally adjustable output in 0.2V increments. This

More information

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down 24V to 12V DC-DC Converter has a programmable 12.0 to 15.0V output in

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual HQ 005. ELECTRIC ACTUATORS QUARTER-TURN ELECTRIC ACTUATORS Installation, Operation and Maintenance Manual s Version Ver. 1 Revision Rev. 1 Document No. HKQI-611 Small & Compact Design High corrosion resistance

More information

Model PRO 9246CH Installation Manual

Model PRO 9246CH Installation Manual Model PRO 9246CH Installation Manual PRE-INSTALLATION NOTES: RF Programmable Features : Feature Selection 1 Flash 2 Flash 3 Flash Default 1st Do L/UL 1 Sec. 3.5 Sec. 1 Sec L, Dbl. U/L 1 Sec. 2nd Accy Lock

More information

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer.

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer. INSTALLATION MANUAL SL- 3 3-Channel Security with Keyless Entry System This unit is designed for professional installation only and must be installed by an authorized Silencer dealer. For Warranty information:

More information

English. Fitting Instructions: Trophy and Trophy SE A of 12. Parts Supplied:

English. Fitting Instructions: Trophy and Trophy SE A of 12. Parts Supplied: English Fitting Instructions: Trophy and Trophy SE A9808015 Thank you for choosing this Triumph genuine accessory kit. This accessory kit is the product of Triumph's use of proven engineering, exhaustive

More information

GLM SERIES CONTROL Users Manual Rev:

GLM SERIES CONTROL Users Manual Rev: GLM SERIES CONTROL Users Manual Rev: 808062 Connecting Power Page 2 Motor Terminal Wiring Diagrams Page 3 Getting Started / Setup Page 4 1. Obstruction Detection Devices Page 4 2. Checking Power and Direction

More information

CA 421 Installation Instructions

CA 421 Installation Instructions CA 421 Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components

More information

Function ECU, Wireless

Function ECU, Wireless Commercial Vehicle Systems Product DATA PD-551-000 Function ECU, Wireless The is a Gateway Receiver system to alert the driver if any monitored tyre runs under its normal pressure or above its normal temperature.

More information

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual

World Leaders in Diesel Fuel Injection Test Equipment. IFT-c. Injector Function Tester Controller. Operating and Servicing Manual World Leaders in Diesel Fuel Injection Test Equipment. IFT-c Injector Function Tester Controller Operating and Servicing Manual HL048 (EN) Issue 4, H1852, August 2011 HARTRIDGE LIMITED IFT-c Operating

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

LI-2B Installation Manual

LI-2B Installation Manual ARCO Pty. Ltd. LI-2B Intelligent Gate Controller Installation/Owners Manual Please do not commence installation until you have read this instruction book. Contents: Introduction Installation Options: Standard

More information

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA MDC150-012301 12V, 30A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi 1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 IMPORTANT NOTE... 3 FAULT FINDING AND DIAGNOSTICS... 3 ABBREVIATIONS... 3 PCB S... 4 OUTDOOR MAIN PCB... 4 INDOOR PCB...

More information

STR3. Step Motor Drive. User Manual

STR3. Step Motor Drive. User Manual STR3 Step Motor Drive User Manual Contents 1 Introduction... 3 1.1 Overview... 3 1.2 Features... 3 1.3 Block Diagram... 4 1.4 Safety Instructions... 5 2 Getting Started... 6 2.1 Mounting Hardware... 6

More information

SECTION 5 DIAGNOSTIC TROUBLE CODES (DTC)

SECTION 5 DIAGNOSTIC TROUBLE CODES (DTC) 5 1. DTC MEMORY SECTION 5 Diagnostic Trouble Codes (DTCs) are logged in a list in TCM memory. The DTCs contained in the list have information recorded as shown in Table 5 1 (DTC example). The TCM is capable

More information

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA).

ThinkTop DeviceNetTM VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA). PD 65493 GB1 20001-01 ThinkTop DeviceNetTM 11-25 VDC DeviceNet is a Trademark of the Open DeviceNet Vendor Association, Inc. (ODVA). Application The ThinkTop is designed to ensure optimum valve control

More information

OCT/21/02 MEGA 670L DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A.

OCT/21/02 MEGA 670L DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. OCT/21/02 MEGA 670L DELUXE 4-CHANNEL CAR ALARM SECURITY SYSTEM Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. MEGA 670 1 MEGA 670 2 OCT/21/02 OCT/21/02 WIRING DIAGRAM H7: 10 Pin White

More information

Function ECU, Wireless

Function ECU, Wireless Commercial Vehicle Systems Product DATA PD-551-000 Function ECU, Wireless The is a Gateway Receiver system to alert the driver if any monitored tyre runs under its normal pressure or above its normal temperature.

More information

Par ts Manual Z-45/25 TM Z-45/25J. Par ts and Service Supplement. Positive Air Shutdown Valve. Serial Number Range

Par ts Manual Z-45/25 TM Z-45/25J. Par ts and Service Supplement. Positive Air Shutdown Valve. Serial Number Range Par ts Manual Par ts and Service Supplement Positive Air Shutdown Valve Serial Number Range TM Z-45/25 TM Z-45/25J Serial Number Range from Z452513A-47001 Part No. 161517 Rev B1 January 2016 Introduction

More information

Purging Air From Divider Block Lubrication Systems

Purging Air From Divider Block Lubrication Systems FROST ENGINEERING SERVICE Purging Air From Lubrication Systems A D I V I S I O N O F G E C S E Y S A L E S & S E R V I C E DESCRIPTION Divider block lubrication systems operate correctly only when all

More information

Installation Instructions

Installation Instructions patent pending Portable Proportional Braking System Installation Instructions Part number 9400 Towing and Suspension Solutions ROADMASTER, Inc. 6110 NE 127th Ave. Vancouver, WA 98682 800-669-9690 Fax 360-735-9300

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System

More information

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state

More information

R & D SPECIALTIES ROTROL I USER'S MANUAL

R & D SPECIALTIES ROTROL I USER'S MANUAL R & D SPECIALTIES ROTROL I USER'S MANUAL TABLE OF CONTENTS INTRODUCTION...2 SPECIFICATIONS...2 CONTROLS AND INDICATORS...3 TIME DELAYS...4 INSTALLATION...5 SYSTEM OPERATION...9 TROUBLESHOOTING...13 OPTIONAL

More information

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web:  - MAKING MODERN LIVING POSSIBLE Quick Setup VLT FCM 300 Series Factory setting Motors type B14 & B34 mounting Reset (pushbutton) Start Jog Speed reference Fig. 1 - Reset to be closed short time for resetting

More information

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 INSTALL 1

MEGA WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM. Installation Manual MEGATRONIX CALIFORNIA, USA MEGA 2500 INSTALL 1 MEGA 2500 2-WAY LCD 4-CHANNEL CAR ALARM SECURITY SYSTEM Installation Manual MEGATRONI CALIFORNIA, USA MEGA 2500 INSTALL 1 MEGA 2500 INSTALL 2 INSTALLATION DIAGRAM H8: 10 Pin White Mini Connector H8 10

More information

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER APPLICATION Replacement of logic board for Models FDO and FDC operators with Rev. 400 wiring. FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K79-3493-400, K79-3493A-400 & K79-3493B-400 WARNING To prevent

More information

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Installation and Operating Instructions. MPPT Solar System Controller ISC3040 Installation and Operating Instructions MPPT Solar System Controller ISC3040 ABOUT THIS MANUAL These operating instructions come with the product and should be kept with it as a reference to all user s

More information

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16 User Manual CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 1 - LIN072UE - 04/16 Table of Contents 1 Introduction... 3 1.1 Precautions Before Starting... 3 1.2 Troubleshooting... 3 1.3 General Disclaimer...

More information

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

ST - II Series POWER SUPPLIES USER INSTRUCTIONS Introduction ST - II Series POWER SUPPLIES These instructions detail the installation and operation requirements for the ST20-II & ST35-II power supplies. These have been designed for operation in RV s

More information

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL Items Supplied with the System: Installation Instructions: Main unit 1. Mounting the module: Plug In LED Mount the module in a suitable location

More information

RP-4000 Reserve Power Control

RP-4000 Reserve Power Control Instruction Manual IM-0580 RP-4000 Reserve Power Control Table of Contents General Information... 2-3 Introduction... 2 Cautions... 2 Receiving/Inspection... 2 Storage... 2 Equipment Return... 2 Identification

More information

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a three phase, on-line, double conversion, solid state Uninterruptible

More information

User s Manual. Automatic Switch-Mode Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger User s Manual Automatic Switch-Mode Battery Charger IMPORTANT Read, understand, and follow these safety rules and operating instructions before using this battery charger. Only authorized and trained service

More information

Specifications. General

Specifications. General For sales & service call Transport Support Tel: +44 (0)1204 368 111 TS Rigid Inclinometer Installation and Operating Instructions ISO9001 CERTIFIED COMPANY United Registrar of Systems Cert. No.1820 Transport

More information

Powerware Battery Charger Module. User s Guide. Models ASY-0652 and ASY

Powerware Battery Charger Module. User s Guide. Models ASY-0652 and ASY Powerware 9170 + Battery Charger Module User s Guide Models ASY-0652 and ASY-0675 .Copyright 2002 Powerware Corporation, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced

More information

GTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications.

GTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications. An ISO 9001:2008 Registered Company GTWY605 Fast Idle, Shift Interlock, I/O 2009-2017 Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications. Introduction The Gateway

More information

Bendix BlindSpotter Side Object Detection System. Installation Guide

Bendix BlindSpotter Side Object Detection System. Installation Guide Bendix BlindSpotter Side Object Detection System Installation Guide Bendix BlindSpotter Side Object Detection System BW2798 (Formerly VOIG0032) April 2013 General Table of Information Contents General

More information

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual Elite Power Solutions Automatic Battery Control (ABC) Operation Manual Elite Power Solutions 335 E Warner Rd. STE 3 Chandler, AZ 85225 www.elitepowersolutions.com ABC Operation Manual Page 1 Table of Contents

More information

DR8010 tm. Hardware Reference Manual. Document Revision B4 May 15, 2018

DR8010 tm. Hardware Reference Manual. Document Revision B4 May 15, 2018 tm Hardware Reference Manual Document Revision B4 May 15, 2018 3380 Town Point Drive Suite 330 Kennesaw, GA 30144 Tel: (770) 422-7845 Fax: (770) 422-7854 www.microkinetics.com Table of Contents 1 The Driver

More information

USERS MANUAL MCD REMOTE OPERATOR

USERS MANUAL MCD REMOTE OPERATOR USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3

More information

APT 4 SECTION. APT 1

APT 4 SECTION.   APT 1 SECTION 4 Manufactured by: PERTH Unit 2-5/511 Abernethy Road Kewdale Western Australia 6105 Ph: +61 8 9353 6577 Fax: +61 8 9353 6578 KALGOORLIE 24 Percy Road Kalgoorlie Western Australia 6430 Ph: +61 8

More information

Product Data Sheet. Part Number: Gen 2 Back of Cab. Product Technical Specifications

Product Data Sheet. Part Number: Gen 2 Back of Cab. Product Technical Specifications Part Number: 116074 Part Description: Fuel Storage Module (FSM) 123 Gen 2 Back of Cab Product Technical Specifications General Specifications Designed Location... Back Of Cab (BOC) Gasoline Gallon Equivalancy

More information

Fitting Instructions: Street Triple from VIN and Street Triple R from VIN A

Fitting Instructions: Street Triple from VIN and Street Triple R from VIN A English Fitting Instructions: Street Triple from VIN 560477 and Street Triple R from VIN 560477 A9808113 Thank you for choosing this Triumph genuine accessory kit. This accessory kit is the product of

More information

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL and SMT package available

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL and SMT package available Silvertel V2.2 Jan 2015 Datasheet Ag9700 Pb 1. Features IEEE802.3af compliant Small SIL and SMT package available Low cost, with minimal external components required Input voltage range 36V to 57V Short-circuit

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

MULTIRACK. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL. Printed in Canada

MULTIRACK. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL.   Printed in Canada MULTIRACK TM Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL Printed in Canada www.garnetinstruments.com GARNET MultiRACK TM Optic / Thermistor Rack Control for Trucks MODEL 688S/688D

More information

Timer Relays - Fixed & Adjustable

Timer Relays - Fixed & Adjustable Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing

More information

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications An ISO 9001:2008 Registered Company Idle Timer Controller - ITC515-A 2015-2018 Ford Transit Contact InterMotive for additional vehicle applications Overview The ITC515-A system will shut off gas or diesel

More information

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD PART NUMBER 393-008-020 Rev. C Table of Contents TABLE OF CONTENTS 393-008-020

More information

Installation and Commissioning of Auxiliary Power Unit

Installation and Commissioning of Auxiliary Power Unit Models PC6012 PC6013 PC6014 PC6015 PC6022 PC6023 PC6024 Installation and Commissioning of Auxiliary Power Unit 30-871-21 Rev. E Warning & Cautions Vehicles with longer wheel bases should have the APU mounted

More information

MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL

MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL This manual covers 1. Gas spreader wireless controllers (Standard) 2. Gas spreader wireless controllers (Plus) 3. 600DC single motor spreader wireless

More information

MULTIRACK GARNET. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL. 688 Manual. Page 1. Printed in Canada

MULTIRACK GARNET. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL. 688 Manual. Page 1. Printed in Canada MULTIRACK TM Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL Printed in Canada GARNET Page 1 GARNET MultiRACK TM Optic / Thermistor Rack Control for Trucks MODEL 688S/688D MANUAL Table

More information

Uninterruptible Power System

Uninterruptible Power System USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible

More information

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide Eaton 9170 + Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with the limits for a Class A digital

More information

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES PART NUMBER: 250-9625 GENERAL APPLICABILITY THIS CRUISE WAS TESTED AND VERIFIED ON: ALL MODELS RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION SAFETY GLASSES KIT CONTENTS/SERVICE PARTS ITEM QTY DESCRIPTION

More information