Timer Relays - Fixed & Adjustable

Size: px
Start display at page:

Download "Timer Relays - Fixed & Adjustable"

Transcription

1 Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing them to be multi-voltage and eliminating failures associated with mechanical components. This guarantees extremely quick switching times and outstanding service life. Manufactured with standard housing and terminal configurations ensures compatibility with standard mini relay accessories. Standard Coil Relay Weatherproof Relays Weatherproof relays seal to IP67. This protection rating is achieved by utilising a shrouded relay housing with an accompanying sealed connector. Offered individually or in kit form in normally-open or changeover configuration. r Relays - Fixed & r relays are microprocessor controlled change-over relay units incorporating a time delay. Depending on the model, the time delay can trigger in either a delay on or delay off configuration. User adjustable models are available ex-stock. Made to order factory preset units available by special order. (Minimum order quantities apply.)

2 Solid State 98 Mini & Micro 99 r 102 r - Factory Preset 104 High Current 106 Specials 107 Voltage Sensor 108 Keys On Lights On 109 Smart Battery Isolator 110 Solenoids 111 Turbo rs 112

3 Solid State Solid state reliability. 9-30V operation. Fast switching speed. Silent operation. No moving parts. Replacement to mechanical relays. Voltage : 12/24V Operational (9-30V) Contact : Brass Body : Polymer Ingress Protection : IP5K4 Supply Current : OFF State <0.5mA ON State 5mA Solid State Relay IONNIC Solid state relays have no moving parts, eliminating failures normally associated with conventional mechanical switching relays. Rated up to 25amps IONNIC Solid State relays provide faster switching time, improved reliability and the convenience of 12/24V operation. 40mm 30mm 30mm No Moving Parts - No Contacts Positively Triggered Negatively Triggered Solid State Part No. Voltage Switching Amps Continuous Max Switching PE14-10P 12/24 Positive PE14-25P 12/24 Positive PE14-10N 12/24 Negative PE14-25N 12/24 Negative For accessories see page

4 Weatherproof Mini relays available - rated to IP67. Most models resistor protected. Full range of accessories available. Models available with mounting bracket. Contacts : Silver Alloy Body : Polymer Ingress Protection : Micro, Mini IP54 Mini - Weatherproof IP67 Operating Temp : -40 C to C P2512R P1524R P1424R PM2512R P1512RWP Mini & Micro 25mm 15mm a 23mm 4.8mm PM2512R Fig 1 Fig 2 4 Terminal - Normally Open (N/O) 5 Terminal - Change Over (C/O) Micro Part No. Voltage Amps Contact Type Terminals Fig PM1412R N/O 4 1 PM1424R N/O 4 1 PM2512R 12 10/20 C/O 5 2 PM2524R 24 5/10 C/O / / Accessories - Micro Part No. Description 47002/10 Micro relay base kit - 10 pack. Interlocking base with mounting bracket Contents: 10 x Bases (47002), 20 x AMP Terminals ( ), 30 x AMP Terminals ( ) Micro relay base. Interlocking base with mounting bracket 47003/10 Micro relay base kit - 10 pack Contents: 10 x Bases (47003), 20 x AMP Terminals ( ), 30 x AMP Terminals ( ) Micro relay base AMP Terminal -. Suits 1-2.5mm 2 cable size. 100 pack AMP Terminal - 4.8mm. Suits 1-2.5mm 2 cable size. 100 pack 99

5 P1512RWP P1512RWP-KIT 69mm 35mm a 35mm Ø6mm Fig 1 5 Terminal - Normally Open (N/O) Fig 2 5 Terminal - Change Over (C/O) Mini - Weatherproof Part No. Voltage Amps Contact Type Terminals Mounting Bracket Fig P1512RWP N/O 5 Removable 1 P1524RWP N/O 5 Removable 1 P2512RWP 12 20/30 C/O 5 Removable 2 P2524RWP 24 10/20 C/O 5 Removable 2 P1512RWP-KIT 12V N/O Weatherproof Relay Kit Kits contain: 1 x Mini Weatherproof Relay P1524RWP-KIT 24V N/O Weatherproof Relay Kit 1 x Base Connector ( ) 1 x Sealing Blank (114017) P2512RWP-KIT 12V C/O Weatherproof Relay Kit 2 x Terminals 1-2mm 2 ( L) 3 x Terminals 2-3mm 2 ( L) P2524RWP-KIT 24V C/O Weatherproof Relay Kit L L Accessories - Mini Weatherproof Part No. Description Relay base connector L Packard Terminal - with pull to seat locking tab. Suits 2-3mm 2 cable size. 100 pack L Packard Terminal - with pull to seat locking tab. Suits 1-2mm 2 cable size. 100 pack 100

6 P1524R P1424R P2512R 41mm 26mm a 26mm Fig 1 Fig 2 Fig 3 6mm 4 Terminal - Normally Open (N/O) 5 Terminal - Normally Open (N/O) 5 Terminal - Change Over (C/O) Mini Part No. Voltage Amps Contact Type Terminals Mounting Bracket Fig P1424R N/O 4 Removable 1 P1512R N/O 5 Removable 2 P1524R N/O 5 Fixed 2 P2512R 12 20/30 C/O 5 Removable 3 P2524R 24 10/20 C/O 5 Removable 3 For bulk packs of 200, add -B to end of part number (eg P2524R-B). PRBC 47000/ / Accessories - Solid State, Mini & r Part No. PRBC Description Mini relay base kit. Interlocking base with mounting bracket Contents: 1 x Packard Base, 5 x Packard Terminals 47000/10 Mini relay base kit - 10 pack. Interlocking base with mounting bracket Contents: 10 x Bases (47000), 50 x AMP Terminals ( ) Mini relay base. Interlocking base with mounting bracket 47001/10 Mini relay base kit - 10 pack Contents: 10 x Bases (47001), 50 x AMP Terminals ( ) Mini relay base Mini relay base. For mounting to PC boards AMP Terminal -. Suits 1-2.5mm 2 cable size. 100 pack 101

7 TIM01 TIM05 Programmable time periods. Compact units. 10A switching current on most units. Clean contacts. r PT Protection : Body : Resistor Polymer Delay Type 0: OFF secs - 10 secs 1: OFF - 5 secs - 60 secs 2: OFF - 30 secs - 10 mins 3: OFF - 5 mins - 60 mins 4: OFF - 30 mins - 6 hrs 5: ON - 30 mins - 6 hrs 6: ON - 5 mins - 60 mins 7: ON - 30 secs - 10 mins 8: ON - 5 secs - 60 secs 9: ON secs - 10 secs r - Delay Type Increase Decrease Delay ON Delay OFF + 15 a 41mm 30mm 30mm r Positive Supply (B+) 31 - r Negative (B-) 15 - r Switch/Control (B+) 5 Terminal - Change Over (C/O) Part No. Function Voltage Amps Delay PT Delayed turn OFF or Delayed turn ON sec to 6 hrs pt Delayed turn OFF or Delayed turn ON sec to 6 hrs For accessories see page

8 Multi Function TIM01 Delay On/Off Red LED indicates when relay is energised. Increase Increase Switch 1: Specifies when timer activates. Decrease Decrease Switch 2: ON: Minutes OFF: Seconds Switch 1: OFF = Delay ON ON = Instant ON - Delay OFF 2: OFF = Once only ON = Cycle ON-OFF-ON-etc 3: OFF = Seconds ON = Minutes 4: OFF = 1-30 ON = : OFF = 24V ON = 12V ON 1 2 Temporary activation at Turn ON TIM05 ON Temporary activation at Turn ON ON 1 2 Delayed Off ON Delayed at Turn On ON 1 2 Delayed at Turn On TIM06 ON Cycle activation at Turn ON ON 1 2 Temporary activation at Turn OFF 72mm 15mm 72mm 15mm 42mm + NC NO INH+ COM 6 Terminal - Change Over (C/O) + a Terminal - Change Over (C/O) 43mm 30mm 30mm TIM01 TIM05, TIM06 Multi Function Part No. Function Voltage Max 12V Delay TIM01 Multi sec to 60 mins TIM05 Delayed turn OFF sec to 60 mins TIM06 Delayed turn ON sec to 60 mins Protected microprocessor timer control circuit. TIM01: Incorporates timer reset terminal. 103

9 C r - Factory Preset User defined factory preset time. Flexible time periods. Compact unit. Clean contacts. Removable mounting bracket. Non-stocked item - lead times & MOQs apply. Protection : Resistor Current Rating : 12V 20 Amps 24V 10 Amps Contact : Copper-Zinc Alloy Body : Nylon PA6.6 Ingress Protection : IP5K4 Operating Temp : -40 C to + 80 C Approvals : CE, RoHS 15 a 56mm 28mm 28mm r Positive Input (B+) 31 - r Negative (B-) 15 - r Switch/Control (B+) 6mm 5 Terminal - Change Over (C/O) Ordering System The fixed range of r Relays are programmed at the point of manufacture hence are a non-stocked item - lead times & MOQs apply. When ordering specify: - Type, - Voltage, -, - Seconds or Minutes. Minimum order quantity of 50 pieces. T20 T30 T31 T Volt Volt Part Number T S (01-60) S - Seconds M - Minutes T20 T30 Delay ON With constant positive feed to terminal 15 Preset Delay OFF With constant positive feed to terminal 15 Preset T31 T35 Delay OFF With positive trigger to terminal 15 Preset Delay OFF With loss of positive to terminal 15 Preset 104

10 atalogu Catalogues Lighting WL 2011 WL2011 Heavy Duty LED Heavy Duty HID Heavy Duty Halogen Marine General Purpose HID Driving Lights Interior Lighting Worklamps To get your copy visit ionnic.com EL 2011 EL2011 Available 2nd Qtr 2011 LED & Halogen Beacons Strobes Lightbars Minebars ROPS Bar Directional Arrows LED Lighting Bus Warning Light Kits Flasher Units Emergency Lighting To get your copy visit ionnic.com Available 2nd Qtr 2011 Lighting Safety Electrical

11 High Current P PR12V200 P141275HD High current power relays. Models available up to 200A. Various mounting styles. Contacts : Silver Alloy Body : Polymer Operating Temp : -40 C to C Ø6mm 46mm 62mm 45mm 76mm Ø6mm Ø6mm 28mm 46mm Terminal - Normally Open (N/O) 75mm 34mm Terminal - Normally Open (N/O) PR12V200, PR24V100 P141275HD, P142450HD Power Part No. Mounting Bracket Voltage Amps Contact Type Terminals PR12V200 Fixed N/O 4 PR24V100 Fixed N/O 4 P141275HD Fixed N/O 4 P142450HD Fixed N/O 4 41mm 28mm 26mm Ø6mm 9.4mm Terminal - Normally Open (N/O) Mini - Power Part No. Mounting Bracket Voltage Amps Contact Type Terminals P Removable N/O 4 106

12 Flag indicator shows relay status in manual or powered condition. Bipolar LED status lamp allows for reverse polarity applications - ideal in low light conditions. Colour-coded push button with lock-up door - allows for manual operation of relay without the need for coil power. White polymer ID tag for labelling in multirelay circuits. Protection : Resistor Contacts : Silver Alloy Body : Polymer Ingress Protection : IP40 Operating Temp : -40 C to + 55 C Approvals : CSA, CE, RoHS Specials 40mm 21mm mm 14(-) mm 14 Terminal - Change Over (C/O) 4 Pole Change Over Part No. Coil Voltage Amps per Contact Contact Type Terminals P C/O 14 P C/O 14 With P4512 mounted Accessories - Specials Part No. Description Amps Terminal No. of Poles Receptacle Relay base 7 M3 Screw 4 14 Blade 107

13 Voltage Sensor Internal change-over relay activates when the voltage falls below or rises above the preset level. sensing range: VS V operation. VS V operation. Example uses: - Helps prevent the over-discharging of a battery. - Triggering an alert when a battery discharges to a preset level. - Automatic activation of a battery charger. Body : ABS Wire Length : 300mm Operating Temp : -0 C to + 50 C + NC NO IC - COM Voltage adjusting screw 5 Terminal - Change Over (C/O) 50mm 70mm 30mm 24mm Voltage 11 Voltage 11 On a Rising System Voltage* Energises User Set Point On a Falling System Voltage* De-Energises User Set Point *VS12 operation illustrated with default User Set Point Used to switch a circuit relative to system voltage. The user only sets the minimum voltage level (User Set Point). The VS12 maximum voltage level is approximately +0.7 volts higher than the User Set Point. The VS24 maximum voltage level is approximately +1.5 volts higher than the User Set Point. When the system voltage reaches the maximum voltage level the internal change-over relay energises switching the COM from NC to NO. When the system voltage falls below the minimum voltage level the internal relay de-energises switching the COM back to NC. Voltage Sensor Part No. Voltage Amps Sensing Range (volts) Factory Trigger Setting Minimum Voltage Maximum Voltage VS ± VS ±

14 Allows normal operation of headlights. Designed to operate park & low beam lights any time vehicle ignition is on. Input available to disable control unit, eg. handbrake switch, door switch. All three internal 30 amp relays turn on 10 seconds after ignition is activated. Compact easy installation. MS-LOR-12V features diagnostic LEDs. MS-LOR-12V-KIT supplied with harness to plug into Toyota Hi-Lux headlight system. 2 year warranty. Body : ABS Wire Length : 300mm MS-LOR-12V 200mm Operating Temp : -0 C to + 50 C MS-LOR-12V -0 C to + 85 C MS-LOR-12V KOLO12DU Keys On Lights On mm 48mm MS-LOR-12V 95mm 24mm 94mm 68mm MS-LOR-12V-KIT - Easy Installation MS-LOR-12V-KIT Keys On Lights On Controller is exceptionally easy to install. Kit is supplied with plug-in harness to suit Toyota Hi-Lux. Ø5mm 40mm 88mm 32mm Plugs directly into headlight harness 107mm Kits suiting other vehicles under development. KOLO12DU, KOLO24DU Keys On Lights On Controller Part No. Voltage Description MS-LOR-12V 12 Suits any negativeley switched headlight MS-LOR-12V-Kit 12 Suits Toyota Hi-Lux only. Supplied complete with plug-in harness KOLO12DU 12 Suits any negatively earthed vehicle KOLO24DU 24 Suits any negatively earthed vehicle 109

15 Smart Battery Isolator SBI Microprocessor-controlled battery isolator designed for use in multi-battery applications. Cost-effective protection against a flat battery. Cooler operating temperature. Silver alloy contacts for longer life. Power saving technology. Fault indication. Surge-protected. 2 Year warranty. Body : Polymer Contact : Silver Alloy Operating Temp : SBI -0 C to + 50 C C to + 60 C Ø7mm 83mm Ø8mm 102mm 7mm 83mm 103mm 74mm 54mm Ø8mm 51mm 55mm SBI-12, SBI-24 Smart Battery Isolator Part No. Voltage Amps Inrush Continuous Off Volts On Volts Current Draw (Amps) SBI SBI

16 Range of normally open & change over style contacts. Integrated mounting brackets. 12 & 24 volt models available Fig 1 4 Terminal - Normally Open (N/O) Fig 2 6 Terminal - Change Over (C/O) ST85 Solenoids Fig 3 4 Terminal - Normally Open Includes Auxiliary Output (N/O) 15-3F 55mm Ø7mm 59mm 55mm Ø7mm Ø8mm Ø5mm 7mm 55mm Ø8mm Ø5mm Ø8mm 60mm 89mm Ø8mm Ø5mm 55mm 70mm 89mm 83mm 70mm Fig 1 Fig 2 Fig 3 Solenoids Part No. Voltage Amps Duty Contact Type Fig ST Continuous N/O 1 ST Continuous N/O Continuous N/O Continuous N/O Continuous N/O Continuous N/O /100 Continuous C/O /100 Continuous C/O F Intermittent N/O 3 111

17 Turbo rs BES-124/ST-4 CST-515 Multiple mounting options. Energise to run or stop models. Models with remote face. 5 Minute Fixed models feature 30A switching capacity via serviceable external relay V operation. BES-925/ST-1 Voltage : 12-24V Current Rating : 10 Amps max BES-925/ST1 91mm 24mm 25mm 29mm 50mm 130mm Remote Face - Part No. Outputs Energise to Remote Face Intervals (mins) Park Brake Override Description BES-925/ST-1 1 Run yes 0.5, 1, 2, 3, 4, 5 yes Non-electronic engine management BES-925/ST-4 1 Run yes 0.5, 1, 2, 3, 4, 5 yes Electronic engine management BES-925/ST-5 2 Run yes 0.5, 1, 2, 3, 4, 5 yes Electronic engine management CTR-M 1 Stop yes 0.5, 1, 2, 3, 4, 5 no Electronic engine management 112

18 33mm 25mm 54mm 75mm BES-124/ST4 Part No. Outputs Energise to Remote Face Intervals (mins) Park Brake Override Description BES-124/ST-1 1 Run no 1, 3, 5 no Non-electronic engine management BES-124/ST-2 2 Run no 1, 3, 5 no Non-electronic engine management BES-124/ST-4 1 Run no 1, 3, 5 no Electronic engine management 112mm 52mm 58mm CST-515 Gauge Mount - Fixed Part No. Outputs Energise to Remote Face Intervals (mins) Park Brake Override Description CST Run no 5 no Relay driven output CST Stop no 5 no Relay driven output 113

Timer Relays - Fixed & Adjustable

Timer Relays - Fixed & Adjustable Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing

More information

Timer Relays - Fixed & Adjustable

Timer Relays - Fixed & Adjustable Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing

More information

Warning Lamps. Bus Warning Light Kits 90. Headlights On Units 93. Flasher Units 94

Warning Lamps. Bus Warning Light Kits 90. Headlights On Units 93. Flasher Units 94 Bus Warning Light Kits 90 Headlights On Units 93 Flasher Units 94 Bus Warning Light Kits Designed and manufactured in Australia. Certified to comply with state transport operation regulations. Automatically

More information

Electronics. Voltage Converters 132. RCD/GPO Inverters 135. Pure Sine Wave Inverters 136. Combi Inverter/Chargers 138. AC to DC Battery Chargers 140

Electronics. Voltage Converters 132. RCD/GPO Inverters 135. Pure Sine Wave Inverters 136. Combi Inverter/Chargers 138. AC to DC Battery Chargers 140 Voltage Converters 132 RCD/GPO Inverters 135 Pure Sine Wave Inverters 136 Combi Inverter/Chargers 138 AC to DC Battery Chargers 140 DC to DC Battery Chargers 141 Power Supplies 142 Battery Monitor 144

More information

Sentry Governors. Class 1. Advanced Diagnostics. Sentry Governor Kits

Sentry Governors. Class 1. Advanced Diagnostics. Sentry Governor Kits Ready to Go also offer a range of pre-configured electronic components that can be used in stand-alone application or integrated into an Es-Key system. In keeping with the same rugged design philosophy

More information

Warning Lamps. Bus Warning Light Kits 110. Headlights On Units 113. Headlight Flasher 114

Warning Lamps. Bus Warning Light Kits 110. Headlights On Units 113. Headlight Flasher 114 Bus Warning Light Kits 110 Headlights On Units 113 Headlight Flasher 114 109 Bus Warning Light Kits Designed and manufactured in Australia. Certified to comply with state transport operation regulations.

More information

ICS Switch Panel. Introducing the new

ICS Switch Panel. Introducing the new Introducing the new ICS Switch Panel New vehicles have proven to be increasingly difficult when it comes to installing electrical accessories, including finding a location to place the required number

More information

Circuit Breaker Types

Circuit Breaker Types Circuit Breaker Types Automatic Reset The circuit breaker cycles continuously during an overload condition until the overload is removed or corrected. Modified Reset The circuit breaker contains an additional

More information

Reference Manual C1S Class 1 Systems

Reference Manual C1S Class 1 Systems Reference Manual C1S 2010 Class 1 Systems Mission Statement To become the preferred supplier of electrical lighting and safety solutions for mobile plant and equipment in the mining and services industry.

More information

BF Series Flasher Thermal flasher circuitry

BF Series Flasher Thermal flasher circuitry BF Series Flasher Thermal flasher circuitry Long life 2A load rating @ 115V AC Low cost Small size All units work on AC and DC input voltage 3 terminal configuration 6V to 115V input voltages available

More information

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down DC-DC Converter has a digitally adjustable output in 0.2V increments. This

More information

Circuit Breaker Types

Circuit Breaker Types Circuit Breaker Types Automatic Reset The circuit breaker cycles continuously during an overload condition until the overload is removed or corrected. Modified Reset The circuit breaker contains an additional

More information

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR MB-3688 120A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR User Manual Warning and Precautions MB-3688 is built with corrosion resistant material and the main electronic assembly is well sealed inside

More information

Circuit Breaker Types

Circuit Breaker Types Circuit Breaker Types Automatic Reset The circuit breaker cycles continuously during an overload condition until the overload is removed or corrected. Modified Reset The circuit breaker contains an additional

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC 703 AUTOMATIC START MODULE OPERATING INSTRUCTIONS Author:- John Ruddock 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 1 - >

More information

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

HGM1750 Genset Security Module USER MANUAL Smartgen Technology HGM1750 Genset Security Module USER MANUAL Smartgen Technology CONTENT 1. SUMMARY... 4 2. PERFORMANCE AND CHARACTERISTICS... 5 3. SPECIFICATION... 7 4. OPERATION... 8 5. PROTECTION... 9 6. PARAMETER RANGE

More information

SRC2013. Switches Relays & Circuit Protection

SRC2013. Switches Relays & Circuit Protection SRC 2013 SRC2013 Switches Relays & Circuit Protection Mission Statement To become the preferred supplier of electrical, lighting and safety solutions for mobile plant and equipment in the mining and services

More information

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...

More information

Lighting Symbols. Rotating LED LED light source with rotating reflector. LED. Rotating Halogen Halogen bulb light source with rotating reflector.

Lighting Symbols. Rotating LED LED light source with rotating reflector. LED. Rotating Halogen Halogen bulb light source with rotating reflector. LED Technology Unrivalled lifespan of up to 100,000 hours together with low power consumption and resistance to high levels of shock and vibration make LEDs the ideal light source for emergency lighting.

More information

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down 24V to 12V DC-DC Converter has a programmable 12.0 to 15.0V output in

More information

Transfer switch GTEC open or delayed transition

Transfer switch GTEC open or delayed transition Transfer switch GTEC open or delayed transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between

More information

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18)

MODUL-CONNECT 1.2. Owner s Manual. Modular, digital wiring and control system. Document Part Number MSMC Rev 9 (04/18) MODUL-CONNECT 1.2 Modular, digital wiring and control system Owner s Manual Document Part Number MSMC Rev 9 (04/18) Service Contact Information E-mail: info@modul-system.com Phone: +46 31 746 87 00 Web:

More information

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant. Advantages of the 72 Alternating Relay The Complete System Solution! Highest Grade Electronic Components RoHS Compliant. The Model 72 series Alternating Relay is designed for duplex pumping systems where

More information

Power Conversion. Battery Chargers. Model

Power Conversion. Battery Chargers. Model Power Conversion Model 1621 www.curtisinstruments.com 1 The Curtis Model 1621 high frequency battery chargers are portable and allow easy charging of industrial vehicle batteries from 24 VDC to 96 VDC

More information

LED Technology. Evolution Design. Hybrid Drive. Lighting Symbols

LED Technology. Evolution Design. Hybrid Drive. Lighting Symbols LED Technology Unrivalled lifespan of up to 100,000 hours together with low power consumption and resistance to high levels of shock and vibration make LEDs the ideal light source for emergency lighting.

More information

Automotive Components Distributors. Airport Products. H. Bowers 2.00

Automotive Components Distributors.   Airport Products. H. Bowers 2.00 Automotive Components Distributors Airport Products H. Bowers 2.00 Airport Products Issue 2.00 All products have been developed with our five key objectives firmly in mind and which we consider to be central

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

REVISED ATM72 Auto Transfer Module

REVISED ATM72 Auto Transfer Module Capricorn Controls DA01ATM1-1 Data & Application Note Page 1 of 8 REVISED - - - ATM72 Auto Transfer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom

More information

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets 86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module

More information

Floodlights. XL-LED Performance IP66 Mini Floodlights 58 LED Weatherproof Floodlights 60

Floodlights. XL-LED Performance IP66 Mini Floodlights 58 LED Weatherproof Floodlights 60 XL-LED Performance IP66 Mini 58 LED Weatherproof 60 The LED Technology XL-LED IP66 Mini Floodlight The Crompton XL-LED IP66 Floodlight has been uniquely developed and engineered to incorporate the latest

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE 8 POWER SUPPLIES Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p8-10 Perth (08) 9248 0410 Sydney (02) 9676 1671 Melbourne (03) 9706 4599

More information

pink relay trigger 12v wire - a fused ignition source relay trigger ground wire-to a good chassis ground to component

pink relay trigger 12v wire - a fused ignition source relay trigger ground wire-to a good chassis ground to component relay logic relay trigger 12v wire - to a fused BASIC RELAY WIRING This relay kit is designed f muli-purpose use. a relay trigger ground wire-to a good chassis ground to component amp A B optional included

More information

ELECTRICAL PANELS. Chap.

ELECTRICAL PANELS. Chap. ELECTRICAL PANELS 360 Panel System Electrical Panels 360 Panel System Modular Panels DC Electric Panels AC Electric Panels AC/DC Electric Panels Aber Marine Panels IP 67 Watertight Panels Rotary Switch

More information

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5 OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER Version 1.5 1 Product Overview EMBC-8025 is an intelligent switching mode battery charger with float maintenance. It is designed to offer maximum

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled PRO EZ-3, 4 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with LI interface and automatic test function For self-contained emergency lighting SELV for output

More information

The new and improved. Minebars

The new and improved. Minebars The new and improved Minebars Engineered to Last Designed and manufactured in Australia, the IONNIC range of Minebars & ROPS bars, are built using the highest quality materials and workmanship. With 16

More information

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage

More information

TOTALINE PROTECTION CONTROLS

TOTALINE PROTECTION CONTROLS TOTALINE PROTECTION CONTROLS SOLID STATE HEAD PRESSURE CONTROL WITH OPTIONAL HEAT PUMP OVERRIDE Head Pressure Controls Temperature sensitive fan motor control which regulates head pressure at low ambients

More information

Transmitters: Relay Valve

Transmitters: Relay Valve Relay Valve VR5/5 Series Appropriate output sequences are affected according to the signal received from the mechanical valve. It is equivalent to the auxiliary relay of an electrical system. Specifications

More information

Item Number Amps Input Banks Price BI $ BI $95.30 BI $ BI $ BI $203.

Item Number Amps Input Banks Price BI $ BI $95.30 BI $ BI $ BI $203. SUBHEAD BATTERY ISOLATION Surepower Industries Eliminates multi-battery drain when two or more battery banks are in a charging system Solid-state electronics Each battery discharges and charges according

More information

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series PRO 50 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output

More information

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL 5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL > Section DSE Model 5220 Automatic Mains Failure & Instrumentation System Operators Manual TABLE OF CONTENTS

More information

Electropneumatic Timing Relays Series 7000 Industrial

Electropneumatic Timing Relays Series 7000 Industrial DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated

More information

Power Distribution System User s Manual. Model: PDS-100

Power Distribution System User s Manual. Model: PDS-100 Power Distribution System User s Manual Model: PDS-0 Section Page Product Overview... 1 I) General Information... 2 II) Important Safety Information... 2 III) Installation... 3 A) Materials Provided...

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING: WARNING: www.altronicinc.com DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO LEAD IMPROPER TO IMPROPER OP- ERATION OF ENGINE THE MACHINE

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Emergency lighting units Product description emergency lighting supply unit with I interface and automatic test function Properties Mains and emergency operation I interface

More information

Prism PI Intelligent features offer advanced performance

Prism PI Intelligent features offer advanced performance Prism PI Intelligent features offer advanced performance The Prism PI integrates an advanced position sensing system and integral pneumatic control for sanitary diaphragm and other linear applications.

More information

INSTALLATION GUIDE. FCC ID NOTICE

INSTALLATION GUIDE.  FCC ID NOTICE REV.5 RS. ADVANCED REMOTE STARTER INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This

More information

MCC Automatic Start-Stop Microcomputer Charger Control

MCC Automatic Start-Stop Microcomputer Charger Control MCC Automatic Start-Stop Microcomputer Charger Control Installation & Operation Instructions Warning: Read ALL the instructions before starting. If anything is not clear, call your dealer or contact Arrgh!!

More information

RF-425LCD PROFESSIONAL VEHICLE SECURITY SYSTEM INSTALLATION MANUAL (FOR AUTHORIZED DEALERS ONLY)

RF-425LCD PROFESSIONAL VEHICLE SECURITY SYSTEM INSTALLATION MANUAL (FOR AUTHORIZED DEALERS ONLY) RF-425LCD PROFESSIONAL VEHICLE SECURITY SYSTEM INSTALLATION MANUAL (FOR AUTHORIZED DEALERS ONLY) THIS PRODUCT IS DESIGNED FOR PROFESSIONAL INSTALLATION ONLY 1 BLUE...TRUNK/HOOD TRIGGER (-) INPUT BLACK/BLUE...4TH

More information

Power Converters. Output Current Function Design Features

Power Converters. Output Current Function Design Features Power Converters Eaton standard product and custom developed DC-DC converters provide regulated power directly to accessory or main loads. Eaton DC-DC converters produce 24V power from a 12V source and

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

PSM72H Push-Button Start Module

PSM72H Push-Button Start Module Capricorn Controls DA02PSM72H1-2 Data & Application Note Page 1 of 6 PSM72H Push-Button Start Module Genset Controls - Timers/Monitors/Trips - Battery Charging Spares & Accessories - Custom Products Ultra

More information

Electro Wizard TM Battery Disconnect Switch

Electro Wizard TM Battery Disconnect Switch Electro Wizard TM Battery Disconnect Switch FR1051 Technical Specifications Grounded Solenoid (Power Supply Coil Negative) CHARACTERISTICS FR1051 Nominal tension Max 12V Max. continuous current on main

More information

AR12 & AR20 Wiring diagram (multifunction display)

AR12 & AR20 Wiring diagram (multifunction display) Wiring diagram (multifunction display) Multifunction display (diesel level, engine monitor, operating hours counter) Wiring diagram (engine start/stop) Battery, ignition switch, starter, alternator Stop

More information

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down). Technical Data Sheet GENSET CONTROL MODULE A121H / A241H Features: Models for both 12V and 24V systems. One model for both spark ignition and diesel engines. 4-alarm light outputs with lamp-test provisions.

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

HIGH POWER SOLENOID DRIVER 1

HIGH POWER SOLENOID DRIVER 1 Elactis SA Switzerland Phone : Fax : E-mail : Web : +41 22 364 65 85 +41 22 364 65 87 info@elactis.com http://www.elactis.com HIGH POWER SOLENOID DRIVER 1 ADRV1012K 1 This datasheet is a preliminary description.

More information

Low and High Voltage Power Supplies

Low and High Voltage Power Supplies Low and High Voltage Power Supplies We work according to ISO 9001: 2008 Since 1994 Fug works according to the quality assurance system ISO 9001. All shipped units are checked and documented in our testing

More information

Installation Instructions

Installation Instructions AQU244 & AQU128 Series Installation Instructions Installation Instructions AQU244 24vdc 5A Supervised Power Supply/Charger module AQU128 12vdc 10A Supervised Power Supply/Charger module Both Mounted in

More information

SDM72 Start on Demand Modules

SDM72 Start on Demand Modules Capricorn Controls DA04SDM72-2 Revised Design Page 1 of 6 SDM72 Start on Demand Modules Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products Application

More information

Thermal Circuit Breaker 3120-F...

Thermal Circuit Breaker 3120-F... Description The 320 circuit breaker/switch combination is an ON/OFF switch with integral overcurrent protection (S-type TO CBE to EN/IEC 60934). The trip element is a bimetal. Type 320 is ideally suited

More information

AUTOSTART 705S V1.00 AUTOSTART 710S / 720S / 730S V1.04 Programming Reference and Check Sheets

AUTOSTART 705S V1.00 AUTOSTART 710S / 720S / 730S V1.04 Programming Reference and Check Sheets The Generator Controls Division of Frank W. Murphy AUTOSTART 705S V1.00 AUTOSTART 710S / 720S / 730S V1.04 Programming Reference and Check Sheets MODEX AUTOMATION FRANK W. MURPHY LTD. Church Road Laverstock

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

Lighting Symbols 100 KM/H

Lighting Symbols 100 KM/H LED Technology Unrivalled lifespan of up to 100,000 hours together with low power consumption and resistance to high levels of shock and vibration make LEDs the ideal light source for emergency lighting.

More information

Model PRO 9246CH Installation Manual

Model PRO 9246CH Installation Manual Model PRO 9246CH Installation Manual PRE-INSTALLATION NOTES: RF Programmable Features : Feature Selection 1 Flash 2 Flash 3 Flash Default 1st Do L/UL 1 Sec. 3.5 Sec. 1 Sec L, Dbl. U/L 1 Sec. 2nd Accy Lock

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE4120 AUTO MAINS FAILURE MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel:

More information

All In one uninterruptible power supply solutions

All In one uninterruptible power supply solutions All In one uninterruptible power supply solutions For the life of your systems with Battery Care concept Integrated Electronic Solution Yet another strong proposition from Adelsystem, result of the continuing

More information

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal) 86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

Installation Contactors RIC, RAC

Installation Contactors RIC, RAC Installation Contactors RIC, RAC 1 Characteristics Rated operational current: 20 63 A Coil voltages: UC 24, 36, 230 V / AC 400 V Hum-free (UC versions) 2 4 contacts NC or NO Extendable with auxiliary contacts

More information

CONSUMABLES POWER 099 POWER CONNECTIONS 108 FUSES 115 CIRCUIT BREAKERS 116 FUSE HOLDERS 126 RELAYS & FLASHER UNITS 131 SOLENOIDS 132 JUNCTION BOXES

CONSUMABLES POWER 099 POWER CONNECTIONS 108 FUSES 115 CIRCUIT BREAKERS 116 FUSE HOLDERS 126 RELAYS & FLASHER UNITS 131 SOLENOIDS 132 JUNCTION BOXES POWER CONSUMABLES POWER CONSUMABLES // PRODUCT FINDER 099 POWER CONNECTIONS 108 FUSES 115 CIRCUIT BREAKERS 116 FUSE HOLDERS 126 RELAYS & FLASHER UNITS 131 SOLENOIDS 132 JUNCTION BOXES With one of the most

More information

CM4200 and CM1000S Starter Control Module Installation Manual

CM4200 and CM1000S Starter Control Module Installation Manual Version Final - VF CM4200 and CM1000S Starter Control Module Installation Manual This manual is for authorized CompuStar dealers. Please thoroughly review this manual before beginning installation. If

More information

Emergency lighting units EM series

Emergency lighting units EM series EM power PRO EZ-3 Emergency lighting supply units Product description emergency lighting supply unit with DALI interface and automatic test function Properties Mains and emergency operation DALI interface

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition WWW.STELLAR.COM Button Function Condition 1 a. Arm and lock doors b. Car finder with sound c. Temporary stop alarm from sounding d. Remote lock doors 1 for 2 sec. Panic Anytime a. Alarm is disarmed b.

More information

CM7200 Option Tables and Programming Instructions Firmware: v3.03

CM7200 Option Tables and Programming Instructions Firmware: v3.03 CM7200 Tables and ming Instructions Firmware: v3.03 If you are new to installing Firstech Series Remote s and/or Alarms, we recommended that you thoroughly review this manual to installing your first unit.

More information

Transmitters: Relay Valve VR4151/4152

Transmitters: Relay Valve VR4151/4152 Relay Valve VR4151/4152 Appropriate output sequences are affected according to the signal received from the mechanical valve. VR4151 VR4152 Precautions Be sure to read before handling. Refer to pages 5-11-2

More information

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT Product description One-LED Solo TM is a non-maintained, self-contained LED emergency luminaire comprising an Omni-LED emergency LED driver, hinged rechargable battery and a flush-mount SELV lamp head.

More information

Gate & Door Controller with LCD and Intelligent Technology

Gate & Door Controller with LCD and Intelligent Technology 2nd Edition Gate & Door Controller with LCD and Intelligent Technology 24Sv1 and 12Sv1 Motor Controllers Setup and Technical information for single motor controller for gates & doors Includes latest Intelligent

More information

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical) MODULAR DEVICES The range of two, three and four pole isolator switches are of a modular design and fit on DIN 50022 rail. Terminal capacity is 25mm 2. Isolator Switches Rating Poles Modules Reference

More information

CRITICAL SPARES GUARD LASER MURPHY RECOMMENDED PARTS 30%OFF ** GAUGES FATIGUE WARNING KIT NOW $ 10%OFF * 15%OFF * keep your fleet moving

CRITICAL SPARES GUARD LASER MURPHY RECOMMENDED PARTS 30%OFF ** GAUGES FATIGUE WARNING KIT NOW $ 10%OFF * 15%OFF * keep your fleet moving CRITICAL SPARES RECOMMENDED PARTS keep your fleet moving 30%OFF ** MURPHY GAUGES RELIABLE. PRECISE. DURABLE. LONG-LASTING. Big discount for our wide selection of Murphy gauges for your industry. Part No:

More information

MM1 Installation Instructions

MM1 Installation Instructions MM1 Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components or

More information

CM7000 Option Tables and Programming Instructions Firmware: v3.03

CM7000 Option Tables and Programming Instructions Firmware: v3.03 CM7000 Tables and ming Instructions Firmware: v3.03 If you are new to installing Firstech Series Remote s and/or Alarms, we recommended that you thoroughly review the full manual before installing your

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE710 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White. MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM H7/1 Green : (-) 200mA Pulse H7 3 Pin H7/3 Blue : (-) 200mA Unlock White LED Indicator Valet Switch H6 2 Pin

More information

functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning

functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning 14 SERES 14 SERES Multi-function electronic staircase timers 1 O 16 A 17.5 mm wide Type 14.01 --8 functions --Switch-off early warning options Type 14.71 --3 functions Time setting from 30 seconds to 20

More information

Emergency lighting units EM powerled

Emergency lighting units EM powerled EM power EM power PRO EZ-3, 1 2 W Combined emergency lighting Driver 1 4 W Product description Emergency lighting Driver with I interface and automatic test function For self-contained emergency lighting

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit

More information

Data Sheet. AmLok.

Data Sheet. AmLok. Data Sheet AmLok options: amgard safety gate switch solutions consist of a range of Control interlocks. The control Interlocks are split into gate switches (Stops) and solenoid Interlocks (Loks). Combining

More information

Relays Micro relays. Characteristic quantities. 6 Relays

Relays Micro relays. Characteristic quantities. 6 Relays 6 Characteristic quantities Rated voltage (load and excitation circuit) 12 V 24 V Operating voltage 8...16 V 17...27 V Ambient temperature -40...+100 C -40...+100 C Response voltage (at 20 C) < 8 V < 17

More information