1 Seametrics Flow Meter & Control Catal0 Distributed / Serviced By: Phone: (800) (513)

2 Seametncs Seametrics Products are covered by a Two Year Limited Warranty policy. Please visit the Downloads section of our website for more information. Technology with a Mission Saving Time Saving Money Conserving Resources " Ave. S. Kent, WA Phone: (253) Fax: (253) lnfoe metrics. corn Provided / Distributed / Serviced By: _if Meters I Controls [Equipment I Service Phone: (800) (513)

3 Table of Contents New Releases EcoPRO 4-20mA Submersible Pressure Transmitter FT400 Series Rate/Total Indicatorc jwave Portable Ultrasonic Meterg Controls A055 Blind Analog Transmitter1 DL76 Data Logger5 FT500-Series Batch Controller9 PD10 Pulse Divider1 3 PS40 Pulse Splitter1 7 RSP5 Solar Panel1 9 a Insertion Meters EX800-Series Insertion Electromagnetic Flow Sensor2 3 EX100/200-Series Insertion Electromagnetic Flow Sensor2 7 1P800-Series Insertion Paddlewheel Flow Sensor3 1 IP100/200-Series Insertion Paddlewheel Flow Sensor3 5 TX800-Series Insertion Turbine Flow Sensor3 9 TX100/200-Series Insertion Turbine Flow Sensor4 3 Pulse Meters MJ-Series Pulse Meter4 7 MJN-Series NSF 61 Pulse Meter5 1 Flanged Meters imag-series NSF 61 Programmable Magmeter5 5 WJ-Series Flanged Pulse Meter6 1 WMP-Series Plastic Bodied Magmeter6 5 WMX-Series Flanged Magmeter6 9 WT-Series Turbine Meter7 3 Low Flow Meters PE-Series Low Flow Magmeter7 7 SEB Low Flow Meter8 1 SES Stainless Low Flow Meter8 3 S-Series, SPT, SPX Low Flow Meters8 7 Please Note: This catalog is for reference only. Please visit for the most current product specifications. Provided / Distributed / Serviced By: Phone: (800) (513)

4 EcoPRO 4-20mA Submersible Pressure Transmitter Rugged and accurate with great noise immunity, transient protection, and thermal performance Features Pressure and optionally temperature Industry standard, 2-wire ma configuration Thermally compensated great where water temperatures vary ± 0.25% FS0 accuracy (EcoPro) or ± 0.1% FSO accuracy (EcoPro+) Low power (9-30 Vdc) Small diameter O. 75"(1.9 crn) Reverse polarity protection Under- and over- current limitation Built-in transient protection Thermally stable 2% over 50 degrees standard 1/4" NPT end cone adapter option Calibrated with patented calibration procedures & NIST traceable equipment Applications Pump and slug tests River, stream, reservoir gauging Stormwater runoff monitoring Wetland monitoring Well, tank, tidal levels Flow monitoring Water resource management Landfill leachate levels Control applications.v4 Ira Mesh CabIG Su ()Dort Ootionall Cahlo EcoPRO :Sensor a TYPICAL INSTALLATION 8.125' (20.6 cm) V a Cable 028' (0.7 cm) Water Inlets Diameter 0.75" (1.9 cm) Provided / Distributed / Serviced By: Phone: (800) (513)

5 GENERAL Length Diameter Weight Body Material Wire Seal Material Submersible Cable Desiccant Terminating Connector Output Operating Temp. Range POWER Transmitter Voltage 8.125" (20.6 cm) 0.75" (1.9 cm) 0.75 lb. (0.3 kg) Acetal & 316 stainless steel or optional titanium Fluoropolymer and PTFE Polyurethane, polyethylene, or ETFE available 1-3 mm indicating silica gel (high or standard capacity) Available 4-20 rna -5 C to 70 C 9-30Vdc (100 ms warmup) 1Higher pressure ratings evadable upon request 2 Burst reduced at PSI,300 3 Depth range for absohde sensors has 14.7 PS! subracted to give actual depth allowed. 4 ± 0.25% FS0 (maximum) at this range HOW TO ORDER EcoPRO (Standard) EcoPRO+ (High Accuracy) TEMPERATURE Element Type Seametncs Thermistor Accuracy t 0.3 C 25 C) ± 0.75 C (maximum 25 C) Range PRESSURE Transducer Type Transducer Material Pressure Ranges' Gauge PSI FtH20 mito Absolute' PSI FtH20 mh,0 Static Accuracy (B. FS.L. 20 C) Maximum Operating Pressure Burst Pressure' Compensated Range 0 C to 50 C Silicon strain gauge 316 stainless steel or optional titanium 14, 5, 15, 30, 50, 100, , 12, 35, 69, 115, 231, 692 ar, 3.5, 10.5, 21, 35, 70, , 50, 100, , 196, , 24, 59, 200 ± 0.1% FS0 (EcoPRO+) ± 0.25% FSO (EcoPRO) 1.1 x FS 3.0 x FS nfl Example: EcoPRO+ 030A - P - S - X2-120H 0 C to 50 C 0 Pressure Range/Poe 0 Sensor Function EcoPRO/EcoPro+ Options 0 Sensor Material 0 Options 0 Cable Length 2 005G 5 PSI, Gauge P Pressure 5 Stainless Steel X No Selection 003H 3m (10ft). HDPE PSI. Gauge T Temperature & Pressure T Titanium 1 NPT Endcone 008H 8m (25f1). HDPE PSI, Gauge 2 NPT Topcap 015H 15m (50ft), HDPE 030A 30 PSI, Absolute 030H 30m (100ft), HDPE PSI, Gauge 050A 50 PSI, Absolute 060H 60m (200ft), HDPE 100G 100 PSI. Gauge 120H 120m (400ft). HDPE 100A 100 PSI, Absolute 180H 180m (600ft), HDPE 300G 300 PSI. Gauge 245H 245m (BOOM, HDPE 300A 300 PSI, Absolute 300H 300m (1000ft), HDPE 'The temperature & pressure option, titanium option, lightning protection, aneroid bellows, NPT endcone and NPTtopcap options are available for additional cost to the base unit. 23m cable included at no charge. ACCESSORIES Aneroid Bellows Desiccant Tube Replacement Desiccant Tube Refill Bottle (18 Refills) Cable Gland Kit Lightning Protection Wire Mesh Cable Support Provided / Distributed / Services] By: Phone: (800) (513)

6 FT400 Series Rate & Total Indicator APPLICATIONS Water Treatment Water Utility Industrial Chemical Handling FEATURES Simple Setup DC Powered (F1430), Loop Powered (F1440) or Battery Powered (FT450) Remote or Flow Sensor Mounted Indicator Rugged Plastic Housing Non-volatile Memory Protective Cover Closed GENERAL INFORMATION The new FT400 series flow computers are microcontroller-based indicator/transmitters that interface with pulse output flow sensors to compute and display flow rate, flow total, and also generate output signals representing flow. The FT430 and FT450 have one scaled pulse output while the FT440 has two. In addition to a scaled pulse output, all three models provide an alternative pulse pass-through output_ Galvanic isolation is provided for most pulse outputs (see table). The FT450 is battery powered while the FT430 may be powered by an external DC power source or an optional internal AC power supply. The FT440 is a "two-wire" or "loop powered" device, meaning that it is powered by the 4-20 ma loop circuit itself. An optional internal AC power supply is available for the FT440 with dual 24 and 12VDC outputs to power both the loop and sensors requiring more power than the loop can supply. Pulse and 4-20mA analog outputs can be used to signal external devices, e.g. certain metering pumps and water treatment controls. Alternatively, one or more pulse outputs can be configured as alarm outputs. FT400 Series flow computers can be password protected to prevent resetting the total or changing configuration settings. All FT400 meters are available in wall or panel mount configurations. The FT430/440 models can be factory mounted on the meter. Some configurations of the FT400 series can be converted from wall to meter or meter to wall after installation if needed. Consult factory for details. Order the FT440 only if a 4-20mA output signal is a requirement and the FT450 if internal battery power is needed. Otherwise the FT430 offers the most flexibility. Provided / Distributed / Serviced By: Phone: (800) (513)

7 Seametrics FEATURES Protective Cover (Optional) eri i Display Setup Keys** Electronics Module Lower Housing Strain Relief Wall-Mount Brackets **Includes password protection for tamper prevention when needed SPECIFICATIONS* FT430 FT440 FT450 Power 9-30 Vdc, 4mA 9-30 Vdc, 4mA (4-20 ma when looppowered) Lithium "C", 3.6 Vdc, replaceable. Life is -5 years depending on usage. Display Rat e 5-digit autorange, mm character height 5-digit autorange, 0.65"/ 16.5mm character height 5-digit autorange, mm character height Units Rate Units Total 8-digit, mm character heitit 8-digit, mm character height 8-digit, mm character height Total Units Outputs Current Sinking Pulse Gallons/Second/Minute/Hour/Day, Liter/Second/Minute/Hour/Day, Cubic Feet/Second/Minute/Hour/Day, Cubic Meters/Second/Minute/Flour/Day. Miner's Inch, mega Liters/Day, Million Galions/Day, Fluid Oz/Second/Minute/Hour/Day Gallon, Gallon x 1000, Liters, Mega Liter, Cubic Meter, Acre Feet, Cubic Feet, Cubic Feet x 1000, Million Gallon, Miner's Inch Day, Acre Inch, Fluid Ounce Scaled Pulse output (0.1 sec duration 6.1 Hz max) or High Alarm output or Low Alarm output Sensor passthrough Sensor Passthrough isolated Scaled Pulse isolated Analog None 4-20 ma loop; Vdc None Pulse Output Range units/pulse units/pulse units/pulse Input 5V pulse or contact closure 5V pulse or contact closure Input Range 1500 Hz Max 1500 Hz Max 550 Hz Micropower GMR Sensor (square wave) K-Factor Range Flow Alarm Output Range Operating Temperature 0' to 55 C (-32' to 131' F) 0' to 55' C(-32' to 131' F) 0' to 55' C(-32' to 131' F) Non-Operating Temperature 40' to 75' C (-40' to 158' F) -40' to 75' C (-40' to 158' F) 40' to 75' C (-40' to 158' F) Environmental NEMA 4X, IP67 NEMA 4X, IP67 NEMA 4X, IP67 Regulatory C E Mark CE Mark C E Mark *Specifications subject to change Please consult our website for current data (wvew.seametrics.com). Provided / Distributed / Serviced By: Phone: (800) (513)

8 FT400 Series Rate & Total Indicator FT400 SERIES PULSE OUTPUT FUNCTION TABLE PULSE OUTPUT 1 (SCALED) F1430 F1440 F1450 TYPE Current sinking Current sinking Current sinking MAX. VOLTAGE 36 Vdc 36 Vdc 36 Vdc MAX. CURRENT 10 ma 10 ma 75 ma MAX. FREQUENCY 6.1 Hz 6.1 Hz 6.1 Hz PULSE WIDTH 100 ms 100 MS 100 TS ISOLATION 300 V 300 V NOTE 1 CONFIGURABLE AS ALARM YES (KO or Low) YES (High or Low) YES (High or Low) PULSE OUTPUT 2 (SCALED) FT430 FT440 (Note 2) FT450 TYPE Current sinking MAX. VOLTAGE 36 Vdc MAX. CURRENT 10 ma MAX. FREQUENCY Not Available 6.1 Hz Not Available PULSE WIDTH 100 ms ISOLATION 300 V CONFIGURABLE AS ALARM YES High or Low) PULSE OUTPUT 2 (PASS-THROUGH) F1430 F1440 F1450 TYPE Current sinking Current sinking MAX VOLTAGE 36 Vdc 36 Vdc MAX. CURRENT 10 ma 75 ma Not Available MAX. FREQUENCY 2000 Hz 150 Hz PULSE WIDTH SAME AS SENSOR INPUT SAME AS SENSOR INPUT ISOLATION 300 V CONFIGURABLE AS ALARM NO NO NOTE 1: 150 Verfeetive isolation when using Searnetacs nrkfopower sensors. NOTE 2: 1,41th 2000 ohm or ia%er puttkip reslstance. Provided! Distributed / Serviced By: Phone: (800) (513)

9 Seametrics DIMENSIONS Dimensions are in inches (Millimeters) 3.56 (90.4) #1.0 Saw Panel Cutout ( ) 3.56 P D D.218 {5.5) 3 37 f95.61 HOW TO ORDER MODEL DC-powered indicator = FT430 Loop-powered indicator/transmitter = FT440 Battery-powered indicator = FT450 MOUNTING Wall mount = -W Panel mount = -P Meter mount = See appropriate meter specification to order meter mounted units. OPTIONS Tamper-evident = -32 Non-resettabie total = -64 Built-in 120/240 Vac/12/24 Vdc power supply (F1430VV & FT440W only, use with magmeters) = -139 Built-in 120/240 Vac/12 Vdc power supply (F1430W only, use with magmeters) -140 ACCESSORIES Data logger (wall mount) = DL76W Power converter, plug-in, 115 Vac, 24 Vdc = PC3 Dual power supply, plug-in, 115 Vac, 12/24 Vdc = PC42 LMI pump power cable = LMI pulse out cable = Provided! Distributed /ServicelBy: Phone: (800) (513)

10 jwave Portable Clamp-On Ultrasonic Flow Meter APPLICATIONS HVAC & Energy System Audits Check System Meters Pump Verification Boiler Testing Leak detection Filter Sizing Ultrapure Water Measurement Fuel Oil Metering Condensate Measurement Clean in place evaluation Fire System testing Hydraulic System Testing FEATURES Portable Efficient Accurate Versatile Intuitive Easy to Own Reusable Location Settings CE & FCC Approved GENERAL INFORMATION Meet the Searnetrics jwave. Now you can capture accurate and reliable flow readings with your mobile device, with less hassle and in less time wherever you need a flow or volume measurement. No wires. No bulky electronics box to lug around. Your ultrasonic sensor hardware installs on the outside of your pipe in a snap and senses through the pipe wall. Your mobile device displays readings and helps you set up the hardware. And Bluetooth replaces the wires. So you'll get your job done more quickly, every time. What's the jwave? The jwave Flow Meter solution starts with the jwave App (downloadable from the app stores) and works on both ios and Android devices. The companion jwave Sensor is a compact, clamp-on ultrasonic transducer device that wirelessly transmits flow measurements. With a programmable controller, the output signal can be fed direct, with no other conditioning required. The jwave is highly portable. Just bring the rechargeable clamp-on sensor in its lightweight, weatherproof case, along with a tablet or smartphone (i0s or Android). Bluetooth connectivity replaces wires, and the jwave App guides you through your application setup. The convenient Cam Cleat lets you mount the sensor on any pipe in seconds no cumbersome clamps required. Bi-directional readings are transmitted to your mobile device for display, and your location's settings are stored in the jwave App, ready for reuse. Now simply release the cleats, then take the compact sensor on to your next location. Provided / Distributed / Serviced By: Phone: (800) (513)

11 Seametncs Power Button Bi-directional Flow Sensing Integrated Ruler Moveable Acoustic Transducers Cam Cleat for Mounting Strap USB External Power Plug & Battery Charger Anodized Aluminum Channel 44011?"..0 Rugged Acetal End Housing & Foot SPECIFICATIONS* Pipe Size 2" -20W Pressure Drop Zero Materials Body Anodized Aluminum Channel & Acetal End Housings & Feet Mounting Straps EPDM Temperature Ambient & Fluid -20' to 150 F(-29' to 65' C) Display English, Metric and Imperial units provided on App Flow Operation Range Bidirectional; -30 to 30 ft/sec (-10 to 10 m/sec) Accuracy 1% to 2% of reading Repeatability 0.1% to 0.3% Output Signal Wireless Bluetooth connectivity to ios or Android device Power Battery (8+ hours) 11W max) 150 rnamp max current Installation 15 diameters upstream 5 diameters downstream for optimal performance Environmental IP65 *Specifications subject to change Please consult our website for current data ( Provided / Distributed / ServicV By: Meters I Controls [Equipment I Service Phone: (800) (513)

12 jwave Portable Clamp-On Ultrasonic Flow Meter DIMENSIONS A AL 2.4 INDUSTRIES USES APPLICATIONS BENEFITS Building Services Hot Water Diesel & Fuel Oils HVAC & Energy System Audits Portable Chemical Cooling Water River Water Check System Meters Non-invasive Energy Management Condenser Water Semiconductor Pump Verification Low-Installation cost Food Water/Glycol solutions Pump Applications Boller Testing Accurate Petrochemical Steam Condensate Uttrapure or Leak detection Row Verification, not calibration Pharmaceutical Municipal Water d e m l n e r a l i z e d water Filter Sizing Temporarily measure flow while Power Generation Process Water ( D e i o n i z e d / R O, etc.) Ultrapure Water Measurement repairing or replacing a Water Wide range of clean fluids Petroleum products Fuel Oil Metering permanent meter Agricultural & temperatures In full pipes Water Treatment Condensate Measurement -No Interruption of the process Clean homogenous liquids Food & Beverage Clean in place evaluation and no down time to install Potable Water p r o c e s s i n g Flre System testing -Tolerates small amounts of air Chemicals Hydraulic System Testing bubbles or suspended solids Provided! Distributed / Serviced By: Phone: (800) (513)

13 Seametrics HOW TO ORDER MODEL jwave (Includes: USB cable, 4oz coupling gel, mounting straps & carrying case) ACCESSORIES Mounting Straps Carrying Case USB Cord Coupling Gel (12oz) Coupling Gel (4oz) Provided / Distributed /Servicefl By: Meters I Controls [Equipment I Service Phone: (800) (513)

14 A055 Blind Analog Transmitter FEATURES Pulse-to-analog converter Current loop powered Smooth output signal Easy set-up Durable APPLICATIONS Telemetry/SCADA Distributed control systems Programmable controllers Chart recording Data logging GENERAL INFORMATION The Sea metrics A055 is a blind (non-indicating) 4-20 ma transmitter, designed for use with almost all Seametrics flow sensors. It accepts a pulse frequency input from the flow sensor, and converts this input into a continuous analog output signal. Power for the transmitter is taken from the current loop itself, so only two wires are required. The digital design makes it possible to span the unit in the field without tools. The frequency at which 20 ma is desired is entered on a set of rotary switches, and an internal microcontroller automatically scales all other values accordingly. An additional benefit of the m icrocontrol ler is its ability to average inputs, for smoothing of the output signal. The degree of averaging can be selected in the field, from 2 to 16 seconds. 1. For maximum environmental protection, the electronic components are encased in a special semi-flexible urethane potting material. The housing is cast from aluminum and fuse-coated. The clamshell housing is connected directly to the flow sensor or, in the wall mount version, provided with mounting feet. The A055 will operate on a relatively wide range of current loop voltages, 24 to 36 Vdc. Lower voltages limit the load that can be applied to the loop without distortion of the signal. (See Load/Supply chart if there is a question regarding voltage vs. load.) A built-in power regulator supplies the appropriate power to the flow sensor. Typical applications for this transmitter are telemetry (or SCADA), distributed control systems, programmable controllers, data logging, and chart recording. Provided / Distributed / Serviced By: Phone: (800) (513)

15 Seametrics Fusion coated cast aluminum housing Easy to use rotary switches for frequency setting Potted for moisture protection Loop power indicator light 420 ma adjustment switches Averaging time switches A055 Wall Mount Shown (meter mount also available) SPECIFICATIONS* Power Vdc Temperature F (0* - 55 C) Input Input Averaging Response Time Frequency Minimum Maximum Setting Output Open-collector solid state sensor 2-16 seconds (switch selectable) 2-60 seconds; 90% of full scale (dependent on Input averaging) 10 Hz (@20 ma) Hz 4 Rotary DIP switches Proportional 4-20 ma *Specifications subject to change Please consult our websife for current data (vnkewseametrics.com). Provided! Distributed / Servicffl By: Phone: (800) (513)

16 A055 Blind Analog Transmitter Load vs. Supply Voltage Loop Power 30 (Vdc) 28 Ope rating Region MOUNTING Load Resistance (Ohms) The A055 can be ordered factory-mounted on the meter, of Seametrics mounting kits part # (for wall to meter or in a wall mount style housing. If needed, it can later be conversion) or part # (for meter to wall conversion). field-converted from one mounting style to the other by use DIMENSIONS A055W (Wall Mount) A055 (Meter Mount) 3.93" " " 1/2" Female NPT 3 Provided / Distributed / Serviced By: Phone: (800) (513)

17 Seametncs HOW TO ORDER MODEL A055 MOUNTING Wall mount = W Meter mount = See appropriate meter specification to order meter mounted units. A055 ACCESSORIES Wall-to-Meter Mount conversion kit = Meter-to-Wall Mount conversion kit = Provided / Distributed / Servicgil By: Meters I Controls [Equipment I Service Phone: (800) (513)

18 DL76 Data Logger FEATURES Easy to set-up, easy to use Weeks/months/years of data storage User-selected sampling interval Data retrieval with laptop computer Single data retrieval device serves multiple data loggers APPLICATIONS Water usage monitoring, reporting, and management Custody transfer regulation Peak demand monitoring GENERAL INFORMATION The 0L76 is a battery-powered data logger that can be used with any Seametrics flowmeter. It stores pulses for up to 3 years, depending on the user-selected frequency of reading. Indicator lights on the unit flash to indicate when it is functioning and when the battery is low. The DL76 can be factory-mounted on the meter or remotely mounted. Housings are rugged cast aluminum, gasketed for environmental protection. When a 0L76 logger is placed into operation, it is easily set up using a laptop computer. Data is also retrieved from the DL76 by means of a laptop and can be analyzed on the laptop or easily loaded on a desktop computer for analysis. *Flowlnspector version 2 software (ordered separately) is required for the downloading, storing, viewing, graphing, charting and printing of data in several formats. Flowlnspector requires a PC with Windows 98, NT, 2000, XP, Vista or Windows 7: CD-Rom drive; 800 x 600 screen resolution: serial port or USB/serial adapter; and a Seametrics DC3 data cable. Flowlnspector can be used with an unlimited number of data loggers. *Older versions of Flowlnspector are not compatible with the DL76. 5 Provided / Distributed / Serviced By: Meters I Controls [Equipment I Service Phone: (800) (513)

19 Seametncs DL76 Data Logger Active El Replace Battery Data port connector for Seametrics DC3 data collection cable Bright status LEDs flash to indicate logger activity and battery life Sturdy gasketed cover with potted electronics 0 Removable foot brackets for remote mounting (wall mount model only) ff-1 Protective data port cap (shown open) Cable to meter (wall mount only) SPECIFICATIONS* Power Battery Life Temperature Rate Units V o l u m e Time Total Units Size C 3.6 Vdc lithium battery (included) -3 years (varies with sampling interval) 0' to 130' F (-18* to 54*C) mls, liters, gallons, Imperial gallons, cubic foots, cubic meters. million gallons Seconds, minutes, hours, days Liter, gallon, Imperial gallon, cubic foot, cubic meter, million gallon, acre-foot, acre-inch, megallter, thousand-gallon Data Storage Capacity Capacity a t Sampling Interval 11 days a t 1 5 seconds 22 days a t 3 0 seconds 44 days a t 6 0 seconds 6 months a t seconds 1year a t seconds 3 years a t seconds Maximum input Frequency Indicators Memory Wraparound 500 Hz Low battery; Power Selectable options (Stop or Overwrite) Clock Accuracy 10 minutes/month (.02%) *Specifications subject to change Please consult our wensite for current data ( com). Provided! Distributed / Serviceil By: Phone: (800) (513)

20 DL76 Data Logger DIMENSIONS DL76W (WALL MOUNT) D L 7 6 (METER MOUNT) DL76 Data Logger Data Active Port R e p l a c e Battery seanisics " 2.06" 4.90" 2.82 I I I LiJ 3.95" 4.52" FlowInspectoem SOFTWARE Flowinspector version 2 software (ordered separately) Is required for setup and operation of the DL76, including data retrieval (with a laptop computer), storage, and analysis. (NOTE: Older versions of Flowinspector are not compatible with the DL76.) r q f 1 p f i, r i E. 19.r:ADU E n t. u n T 5 r x, 4 I I a Li Flowinspector Capabilities: Manage multiple loggers Record up to 3 years of data (depending on sampling interval) View current rate and total Download files to laptop Download files stored on the laptop Display flow information as a graph Display average and maximum/ minimum flow rate for any selected time period Zoom in to graph any time period Show daily flow totals in table format Append multiple files Print graphs and tables Export data to an Excel spreadsheet (.csv) or simple text (.txt) file 3159' Dais Logglor: 0 I, I 1 _ IMP' f- Oa Low 5 iabecl t 0 1 ft... LI NI. Y , ,2 imon a,, 4, Fin A R9t eoaufla Gab 150Dra A n uivor-vr,.,p '.et it Foca. CM OM I a s i V S Ull Cl. I I 1 d e l e 1 I. I I bra,ffie 1 w d--- me.4 U /11AL W i l III _ EL 1254 MOS 0 111AZ MAP ' A ' 61Er 01/1140 C : I C MOS 0 AIMS C ; 4 5 C otni.to W EU 2,0.. i i ) : /11108 [ 09:58: 01/11/ :59:15 01/11/08 _ Olt 1/ i. 10:01: 2 10: /11/08 01/ i 1 lanaos 01/11/ : /11108 CO En ern etnme two. cc 00'- a.m..1'4 41 _ 7 Provided/ Distributed /Serviced By: Phone: (800) (513)

21 Seametncs ORDERING INFORMATION MODEL Data Logger = 0L76 MOUNTING Wall mount = W Meter mount =See appropriate meter specification to order meter mounted units. SOFTWARE FI-SW Version 2 DL76 ACCESSORIES Data Logger Cable for Laptop = DC3 NOTE: If used with a laptop configured with a USB port, a serialto-usb converter cable is required. Four cables have been tested and proven compatible: 10 Gear UC-232A; Keyspan USA-19HS; AirlIn14101 AC-USBS; and Golds GXMU NOTE: FlowInspector software Is provided at no charge but must be ordered as a separate line item. Provided / Distributed / Servic81 By: Meters I Controls [Equipment I Service Phone: (800) I +1 (513)

22 FT500-SERIES Batch Controller FEATURES Batch control Regeneration control High/low flow rate monitoring Water usage monitoring APPLICATIONS Cosmetics manufacturing Water treatment system maintenance Water leakage detection Precision refill of cooling towers & tanks GENERAL INFORMATION The FT500-Series is a batching flow processor with additional output controls. It is designed for use with Seametrics flow meters and flow sensors, as well as other manufacturer's products which have frequency output proportional to flow. In addition to batch functions, the FT500-Series indicates flow rate, and other data in large 3/8" (9.66 mm) digits on an easily-read, backlit display. Units of measure are user selectable, and range from milliliters per second to millions of gallons per day. The unit can be 110 Vac powered with a standard 3-wire cord (included), 220 Vac powered (optional), or DC powered through an internal terminal strip (battery not included). 9 An analog output of 4-20 ma is available both in active and passive loop configuration, and in 0-5 Vdc or 0-10 Vdc outputs, and can be used in applications such as flow rate logging. Two programmable pulse scaled outputs are also standard, and can be used, for example, to provide proportional chemical feed with a pulse-responsive metering pump. The housing is supplied with two brackets for wall-mount applications, or the top/bottom housings can be easily separated and reassembled for panel-mount. Provided / Distributed / Serviced By: Phone: (800) (513)

23 Seametrics Cover Screws* Display Setting Keys Indicator Lights *Can be ordered cross-drilled for seal wire SPECIFICATIONS* Power 115 Vac, 50/ ma, 12 Vdc iii 750 ma or Vdc (220 Vac optional) Temperature 32* - 130' F (0* - 55' 0) Enclosure Batch Outputs Max Pulse Output Memory lypa Sensor Power Display Units Analog Output Sensor Input Environmental Precision cast aluminum, NEMA 4X, panel or wall mount configuration Two form C (SPDT) relays, 115 Vac 64 max 100 ma at 60 Vac/Vdc, opto-isolated, open-collector Non-volatile EEPROM with auto-backup 12 Vdc, 10 ma Totalizer = 8 digit Rate - 5 digit, backlit Volume - Gallons, cubic feet, cubic meters, millions of gallons, milliliters, fluid ounces, pounds, liters Time = Seconds, minutes, hours, days 4-20 ma passive opto-isolated; 4-20 ma active; 0-5 Vdc, or 0-10 Vdc Hz, ESD protected, Interfaces to current sinking sensor output NEMA 4X Setup Memory Non-volatile EEPROM, auto-backup *Specificadons subject to change Pfease consult our website for current data ( Provided! Distributed / Serviol By: Phone: (800) (513)

24 FT500-SERIES Batch Controller > FT520 Batch Controller In Batch Processing Mode, the display indicates a flow rate on the top line, and one of three configurations on the bottom line: an accumulated total flow (resettable), accumulated batch flow, or batch process bar graph. The batch output is controlled via two relays. The main relay starts and stops the batch as a set, or the auxiliary "prewarn" relay can be used to operate a second valve. This allows increased accuracy by engaging a staged shut off at the end of the batch. Settings are: - SET Batch Size - SET Prewarn Size - SET Flow volume units - SET Rate of flow in time base - SET Decimal from whole numbers, to tenths, to hundreths - SET K-factor - SET Pulse (scaled) Output 1 - SET Pulse (scaled) Output 2 - SET 20 ma Rate for maximum estimated flow - Clear Total > FT Filter Regeneration In Filter Regeneration Mode, the display indicates a flow rate on the top line, and one of two configurations on the bottom line: an accumulated total flow (resettable), or batch process remainder. The regeneration process is initiated by setting a target volume, a set value for regeneration time as well. A single relay or alternate relay setting allows control of either single tank or alternating dual tank systems. Settings are: - SET Flow volume units - SET Rate of flow in time base - SET Decimal for rate and total to two decimals - SET K-factor - SET Pulse (scaled) Output 1 - SET Pulse (scaled) Output 2 - SET 20 ma Rate for maximum estimated flow - SET Regeneration Volume - SET Regeneration Time in seconds (3 digits) - SET Relay Mode to one or alternate relays - Clear Total > FT Flowrate Alarm In Flowrate Alarm Mode, the display indicates a flow rate on the top line, and on the bottom line, an accumulated total flow (resettable). The user sets a minimum and maximum flow rate, and if the flow exceeds the min/max paramenter, relay1 or re1ay2 will close. The output relay will stay latched until the flow rate increases/decreases back between the min/max settings. Settings are: - SET Flow volume units - SET Rate of flow in time base - SET Decimal for rate and total to two decimals - SET K-factor - SET Pulse (scaled) Output 1 - SET Pulse (scaled) Output 2 - SET 20 ma Rate for maximum estimated flow - SET Low Flow Alarm - SET Hi Flow Alarm - Clear Total > FT522 Usage Monitor In Usage Monitor Mode, the display indicates one of two configurations: an elapsed time and elapsed flow, and a flow rate and accumulated total flow (resettable). A time period is set to monitor for a set maximum total flow. If the total flow is reached within the set time, an output relay is closed. The output relay stays latched until the system either resets automatically after the set time, or is reset manually via Stop/ Start. A reset condition clears the elapsed time and flow, but not the accumulated total flow. Settings are: - SET Flow volume units - SET Rate of flow in time base - SET Decimal for rate and total to two decimals - SET K-factor - SET Pulse (scaled) Output 1 - SET Pulse (scaled) Output 2 - SET Time Period from hours - SET Alarm Reset to automatic or manual - SET Alarm Point in Flow (8 digits) - SET 20 ma Rate for maximum estimated flow - Clear Total 11 Provided / Distributed / Serviced By: Phone: (800) (513)

25 Seametncs DIMENSIONS " 1/2" NPT 6.42" TYPICAL DUAL FLOW BATCH APPLICATION ALTERNATING TANKS APPLICATION FT520 High-Flow Valve TX Flow Sensor Low-Row Valve Staged shut-off at end of batch ORDERING INFORMATION MODEL MOUNTING O P T I O N S AC/DC Power, Rate/Total/Batch Indicator = F1520 Usage Monitor = FT522 Wall mount = W Regeneration Control = -84 (FT520 Only) Alarm Relay Output = -86 (FT520 Only) 220 vac Input = -121 Provided / Distributed / Servizl By: Phone: (800) (513)

26 PD10 Pulse Divider FEATURES Easily adjustable rotary switches Mates with LMI and other common metering pumps Flexible relay contact output APPLICATIONS Pace electronic metering pumps Boiler/cooling tower feed and bleed Lower frequency output of high frequency meters GENERAL INFORMATION Designed for use as a meter accessory, the PD10 divider is used primarily for pacing electronic metering pumps. Any number from one to 9999 can be set on rotary switches. Each time the divider has received the set number of pulses from the meter, it puts out one pulse to stroke the pump. The PD10 is also useful in boiler and cooling tower feed and bleed operations, and for lowering frequency output of high frequency meters. Compatible with all Seametrics flow meters, the PD10 creates a programmable pulse meter with an easily adjustable pulse rate. The PD10 comes in two different housings: an enclosure that can be mounted near the pump, and a watertight housing for mounting on the meter. Power for the PD10 can be supplied by the metering pump if the pump has a sensor power supply. This is the case with LMI externally-paced metering pumps. Some pumps require an external power supply, available from Seametrics. LMI and Seametrics connectors are available. 13 Provided / Distributed / Serviced By: Phone: (800) (513)

27 Seametrics Protective cover Seametacs PD10 To adjust divulge, dscontwol from po.ci then remove cover and Sal Switches Rotary Switches (4) Mounting Holes: (Double-backed pressure-sensitive tape also supplied standard) Potted for environmental protection Wall (Pump) housing (Meter mount also available) Seametrics connector for plug-in meter connection 2 foot cable to leads or metering pump connector SPECIFICATIONS* Enclosure W a l l (Pump) Mount Epoxy-encapsulated ABS housing with cover Meter Mount Cast aluminum sealed housing Temperature 0' to 130 F (-18' to 55 C) Divider Range Ito 9999 Setting Mechanism Power Maximum Sensor Load Maximum Input Frequency Maximum Output Frequency Output Output Pulse Width Input Connection W a l l Mount Meter Mount Output Connection Wall Mount Meter Mount Rotary switches ma 20 ma 350 Hz (pulses/second) 8 Hz (pulses/second) Solid state relay; V, 170 ma max AC/DC 0.1second Seametrics connector Terminal Pump connector on 24 inch lead Comes with 18 foot lead *SpecitTcations subject to change Please consult our website for current data ( Provided! Distributed / Seryigl By: Phone: (800) (513)

28 PD10 Pulse Divider DIMENSIONS PD1OW 5.1" 2.7" Seametrics PD1 0 To adjust divider, disconnect from power Men remove cover and set switches 4.625" PD10 Meter Mount " 2.57" 1/2'' Female NPT ROTARY SWITCHES The PD10 allows very easy changing of pulse rates using rotary strokes, simply by rotating the dials to the appropriate setting. switches. The four numbered rotary switches marked "1000", In the examples below, the pumps would stroke once when "100", "10", and "1" control the ratio of meter pulses to pump the meter pulses 1521 times, or 8 times, respectively. 15 Provided / Distributed / Serviced By: Phone: (800) (513)

29 Seametncs ORDERING INFORMATION MODEL MOUNTING OPTIONS PD10 Wall Mount = W See individual meter specification for ordering meter mounted units LMI pump connector, 5 pin = -106 LMI pump connector, 4 pin = Included ACCESSORIES Plug-in power converter Vac, 24 Vdc (powered applications only) = PC3 Cable, 2 connector, LMI pump, 12 feet (PD1OM only) = Provided / Distributed /ServItit By: Meters I Controls [Equipment I Service Phone: (800) I +1 (513)

30 PS40 Pulse Splitter FEATURES Rugged ABS plastic housing Optoisolated Transistor and relay outputs APPLICATIONS Cooling tower/boiler water treatment Pacing chemical metering pumps Driving multiple pumps, counter timers, remote totalizers r FLOW METER Red VDC1 Black - Ground INPUT Seametr cs PS40 OUTPUT O U T P U T Red + Pulse R e d 4- Pulse Black -Pulse B l a c k - Pulse GENERAL INFORMATION The P540 is a low-voltage device that allows a Seametrics flow sensor to drive multiple (up to four) pulseresponsive devices, such as solenoid-driven chemical metering pumps, counter timers, or remote totalizers. It requires an external DC power supply for operation and can provide power to a single low power Seametrics flow sensor, such as an MJE meter. It can also be used with a dry contact sensor, such as the MJR reed switch meter. DIMENSIONS [113.33mm] 4.625" mm] I I I _ 1 ri I " ' [04_83mm] mm1 SPECIFICATIONS* Power Relay Optolsolation Outputs Vdc Operational frequency = 50 Hz max Contacts = 250 ma max, 36 Vdc max, 3W max 10 ma 30 Vdc max Three open collector optoisolated One Form C relay ',Specifications subject to change Please consult our website for current data ( 17 [130.30mm] Provided / Distributed / Serviced By: Phone: (800) (513)

31 Seametrics Connections. Remove the PS40 cover to access the terminals. Follow the Connections diagram. Use the included nuts to secure the strain reliefs on the inside of the enclosure before connecting to the terminals. Power. A DC power supply of 10 to 32 Vdc is required. Connect the +V and -V terminals to the DC + and - as shown. Sensor. If using a two-wire (e.g., MJR meter), note which two of the three terminals are to be used. Either of the sensor wires can be connected to either of these two terminals. Three-wire sensors (e.g., MJE meters) are polarity-sensitive and must be connected to the appropriate terminals by standard Seametrics color code: red is +, black is -, and white is Signal. Output. Three of the outputs are transistor, the fourth is relay. The transistor outputs will operate almost all pulseresponsive metering pumps and all Seametrics controls, provided that the polarity is correct. The relay output is identified by its terminals marked NO (normally open), COM (common), and NC (normally closed). The relay output will operate essentially everything, includingthe very rare pump or control that will only work with dry contact. Caution: The relay output is designed for electronic controls only. Maximum current load is 250 ma. High Speed Input. It may be occasionally desirable to use the PS40 with a high-speed input, such as an IP800 paddlewheel flow sensor. If the sensor will be putting out more than 50 pulses per second, it is necessary to disable the relay output, which cannot operate at such high speeds. To do this, clip the jumper marked JP1 (see diagram). Note that the relay output terminals cannot be used in this case. CONNECTIONS (10-32 Vdc power supply MJE METER ( C MJR METER- TWO-WIRE CONNECTION o S S Clip this jumper for high speed operation -0 0 Do not use for high speed operation rn ni co Provided / Distributed / Servisl By: Phone: (800) (513)

32 RSP5 Solar Panel FEATURES Includes 5 watt solar panel, mounting hardware, and 12V solar charge controller Reliable, maintenance-free operation Powers most Seametrics products with the addition of a low cost Amp-hour Sealed Lead Acid battery APPLICATIONS Remote metering applications where electricity is unavailable Back-up power supply for uninterrupted operation 4, MINIM MIN 1 NIM SUNGUARD H GENERAL INFORMATION The RSP5 solar panel makes it possible to use Seametrics flowmeters in remote applications where a reliable source of electricity is not available or practical. The RSP5 is intended for use with a standard 12V, Amp-hour Sealed Lead Acid battery (not included). It comes standard with a charge controller and corrossion-resistant mounting hardware. The RSP5 can also be used to provide up to a 40-day back-up power supply for periods of darkness. 19 Provided / Distributed / Serviced By: Meters I Controls [Equipment I Service Phone: (800) (513)

33 Seametrics BATTERY SELECTION For powering Seametrics mechanical meters along with display electronics, use a 12V Sealed Lead Acid (SLA) deep-cycle battery with a minimum capacity of 22 Amp-hours. This should provide a conservative 40 day backup with maximum battery service life. Marine/RV grade deep-cycle batteries or automotive batteries may be used but must be upsized in Amp-hour capacity by two times and four times respectively to achieve the same battery service life in most applications. For powering Sea metrics low power (<50mA) magnetic flow meters (AG2000, WMP, WMX and low power EX-Series, etc.) use only deep-cycle SLA batteries (not marine/rv or automotive grade batteries) with a minimum capacity of 33 Amp-hours. In climates where meters are operating in full pipe mode much of the time with extended periods of cloudy days, operating continuously through the year, or in latitudes above 50 degrees, the required battery Amp-hour capacity should be reviewed before selection. To learn more, consult the Appendix in our solar power application note found at In summary, the minimum recommended battery capacity, as described above, will be adequate in most climates and applications. However, under marginal conditions, a larger capacity battery may provide superior reliability, better battery service life and lower life-cycle costs. LOCATION The solar panel should be oriented as much as possible toward the midday sun. Locate where there is no significant shading of the solar panel. The Solar Charge Controller and Sealed Lead Acid (SLA) battery should be located in close physical and thermal proximity. Both must be shaded from direct sunlight to minimize temperature differences between them which will greatly diminish the battery service life. Also insulate the bottom of the battery if heat could be absorbed from the surface (concrete, metal etc.) on which the battery is resting. Also take measures to prevent accumulation of moisture (rain, snow, ice, flooding) between the battery terminals which could discharge the battery. If the battery and Solar Charge Controller are housed in an enclosure, the outside must be white or shiny metallic to minimize solar heat build up inside that is seriously detrimental to the service life of the battery. Even light colors (such as the standard ANSI 61 Gray) can elevate the interior of the enclosure by 40F (22C.) If other colors are used, the enclosure must be shaded from direct sunlight or painted glossy white. In addition, because even sealed batteries could vent if the Solar Charge Controller fails, for safety reasons the enclosure should be vented, particularly if it contains other electrical equipment. SPECIFICATIONS* Electrical C u r r e n t 290 ma (typical at design operating point) Voltage 17 V (typical at design operating point) Dimensions H e i g h t 14.2" Width 8.5" Weight 4 pounds (solar panel and mounting bracket) Mounting Bracket, band clamps and mounting hardware for 1-1/2 or 2 inch vertical pipe Operating Temperature Range 40 F to +158 F(-4O C to +70 C) Change Controller High efficiency series PWM regulator with temperature compensation and built-in lightning protection *Specifications subject to change Please consult our webslte for current data (www_seametrics.com) Provided / Distributed / Serv,e1 By: Phone: (800) (513)

34 RSP5 Solar Panel I NSTA LLATI 0 N The solar panel is designed to mount to a either a 1-1/2 to 2 inch diameter vertical pipe. First attach the 45 degree angle bracket to the panel with the two M6 bolts, flat washers and nuts provided as shown. Before tightening the bolts. Be sure to position the bracket to the side of the black cable cover rather than over it to avoid stressin.g the panel (At latitudes above 50 degrees performance may be improved by bending the bracket so that the angle of the panel to the horizontal is increased to approximately the local latitude plus 15 degrees. To avoid damage to the Panel. do this before bolting the bracket to the panel). Next use the two sets of 1/4-20 bolts, nuts, flat and lock washers to attach the angle bracket to the pipe mount C-channel. Then attach the entire assembly to the pipe using the two band clamps as shown. Turn the panel to face true (not magnetic) south in the northern hemisphere or north in the southern hemisphere before tightening the clamps securely. Connect the solar charge controller, flow meter and battery as shown in the wiring diagram. Clean battery terminals and secure connections to the battery using grease or other means of preventing corrosion. For safety, an in-line fuse holder should be installed at the positive battery connection with a 1 Amp time lag (slow-blow) fuse. In unprotected locations a weatherproof fuse holder (such as Bussmann HFB-R) and outdoor-rated wirenuts should be used. 11/2 to 2 inch pipe 1/4-20 hardware C-channel band clamps solar panel M6 hardware 21 Provided / Distributed / Serviced By: Phone: (800) (513)

35 Seametncs WIRING DIAGRAM AdE:=WF wirenut connector s, 4 places red black 0+ 0 Flow Sensor or Display black black yellow black black fad SOLAR BATTERY fuse holder with IA fuse Solar Charge Controller 12V SLA Battery MAINTENANCE Periodic cleaning of the solar panel glass is recommended to remove dust accumulation. Snow and ice may need removal if it remains more than 2 weeks. Installing the panel at a steeper than 45 degree angle may make this unneces- sary in most areas. Battery service life for good quality SLA batteries should be 4-6 years. Actual maintenance replacement interval will depend on local conditions and criticality of data. ORDERING INFORMATION MODEL Solar Panel Kit = RSP5 Provided / Distributed / Ser121 By: Phone: (800) (513)

36 EX800-SERIES Insertion Electromagnetic Flow Sensor APPLICATIONS Conductive fluids Small pipe applications (1"-12") Industrial processes Chemical metering pumps Fertigation FEATURES No moving parts Economical Durable Easy to install Easy to maintain GENERAL INFORMATION EX800-Series insertion electromagnetic flowmeters are designed for use with conductive liquids in 1 to 12" pipe. A choice of materials (stainless steel, brass, and PVC) allows the meter to adapt to a range of temperature, pressure, and corrosive environments. The EX800 is highly suitable for difficult applications with changing viscosities and pulsating flows, such as air-driven diaphragm pumps. With no moving parts, these meters can be used in "dirty" applications where debris would foul a mechanical meter. Like all magmeters, when used in chemical injection applications, these meters should be installed upstream of the chemical line (or far enough downstream to allow complete mixing of fluids before the meter). Designed for modularity and versatility, the EX800-Series has a current-sinking pulse output that can be combined with the appropriate transmitter or indicator for the application. For analog output and display of rate and total, an FT400 series indicator can be used. Blind analog output is provided by the A055. The PD10 can be used to divide the pulse for pacing chemical metering pumps and the DL76 (data logger) is also compatible. Modules can be wall- or meter- mounted. If the EX800 meter is used with a programmable controller, the output signal can be fed direct, with no other conditioning required. EX800-Series fixed depth insertion meters require special fittings. Factory installation in the fitting ensures correct depth placement in the pipe. The EX800-Series meter can be ordered in a full power model when a source of electricity is available, or in a low power model that can run on an external battery with solar panel. Reverse flow output and immersibility are optional. 23 Provided / Distributed / Serviced By: Phone: (800) (513)

37 Seametncs Cover. or electronics module Powder coated aluminum housing Power cord strain relief 0-ring, EPDM (Viton optional) Sensor body (Stainless, Brass, PVC) PVDF electrode cap Hastelloy electrodes SPECIFICATIONS* Pipe Size r to 12" Materials Mechanical Electrodes Housing Electrode Cap 0-Ring 316 SS/Brass/PVC Hastelloy Cast powder-coated aluminum PVDF (Kynar) EPDM standard (VIton optional) Power F u l l Power Vdc, 250 ma Low Power Vdc, 40 ma average with 250 ma peaks Flow Rate ft/sec ( m/sec) Temperature Ambient Temp 0 to 160' F (-17' to 72' C) Fluid Temp : Brass/SS 32' to 200' F(0' to 93 C) Fluid Temp: PVC Pressure Brass/SS PVC Minimum Conductivity Calibration Accuracy Output 32 to 130 F(0' to 55' C)6 0 psi 200 psi (13.8 bar) 150 psi (10 75 F 20 microsiemens/cm +1-1% of full scale Square wave pulse, opto isolated, 550 Hz G 20 ft/sec Empty Pipe Detection Software, defaults to zero flow *SPecificaUons subject to change Please consult our webolte for current data ( Provided / Distributed / Serv041By: Meters I Controls [Equipment I Service Phone: (800) (513)

38 EX800-SERIES Insertion Electromagnetic Flow Sensor DIMENSIONS ' 2.80" 7.11 cm EX cmX8206. E 40cm85"17. EX cm ( T O P OF TEE) PRESSURE VS. TEMPERATURE (PVC) Temperature T GO" P.S. I. 70' 80' 9 0 ' 100' 110* ' 140' 200 SIZE 1/2" 3/4" 1" Dim A Dim A SIZE Dim C 1-1,/2" 2" FLOW RANGE Nominal Pipe Size 1" 11/2" 2" 3" 4" 6" 8" 10" 12" Min GPM Min LPM Max GPM Max LPM AQUA TECHNOLOGY GROUP Provided! Distributed / Serviced By: Phone: (800) (513)

39 Seametncs EX800-COMPATIBLE FITTINGS Tee Saddle Weld/Braze Sweat Tee Fkonze 1-4" 3-4" 3-12" 14' PVC 1-2" 3-8" Stainless Steel 1-2" 3-12" Carbon Steel 1-2" 3-12" Ductile Iron 3-12" : ORDERING INFORMATION Sensor Orli y. Sensor Only Description Size Sensor Material Options kt" -3' = EX810 4". 8" EX E5830 Brass = B 316 Stainless Steel - S PVC - P Reverse Plow Output = 45 lmmersiblitly = -40 Low Power Option = -60 Wong 0-Ring =.125 J FT400 Series (External Power) Mounted on Sensor Description Size Sensor Material Options Rated, total Indicator with pulse & 4-20 ma output, externally powered (FT400 Series' mounted on the sensor. FT430 1.'" 3" F1430 4' - 8' = F " = FT440 1.* - 3' = E5515 FT440 4' - 8' = F " EX1335 Brass.. B 316 Stainless Steel = S PVC = P Reverse nary Output a -15 Tamper Evident Kt = -32 Low Power Option = -50 Mom-resettable Total u -04 Dual Relay Output = 418 Vdon 0-Ring = -125 Hinged Display Cover= -126 A055 Mounted on Sensor Description Size Sensor Material Options Blind 4-20 ma analog transmitter (A055) mounted on the sensor. 1'' :-.1" = ' 8 - ) " - 0(832 Brass = B 316 Stainless Steel.5 PVC - P LMI Pump Connector = -06 Reverse Flow Output = -15 Low Power Option = -50 Reytronicse Series-A Pump 5-pit Connector w 406 Wore 0-Ring = -12s DL76 Mounted on Sensor Description Size Sensor Material Options Data logger (DL76) mounted on the sensor " " 8" " = Brass - B 39.6 Stainless Steel - S PVC= P Reverse Flew Output = -15 Tamper Evident Kit u -32 Loss Power Option = -50 Viton 0-Fling = -125 PD10 Mounted on Sensor Description Size Sensor Material Options Pulse Divider {P010) mounted on the sensor. P"" -3" - EX8113 4" 8" " = EX338 Brass - B 316 Stainless Steel - S PVC = P All Pump Comector = -06 Reverse Flow Output = Ft. Cable for LMI Connector= -37 Loa Power Option u 4.0 Royal:mice* Series-A Pump 5-pin Connector =.106 Won 0-Ring = -125 _ *Consult factory for surtable applications "Requires appropriate fitting. Provided / Distributed / Servgl By: Meters I Controls [Equipment I Service Phone: (800) (513)

40 EX100/200-SERIES Insertion Electromagnetic Flow Sensor FEATURES No moving parts Durable Adjustable depth Hot-tap available Brass or stainless steel lmmersibility available Reverse flow output available APPLICATIONS 3"- 48" pipe (up to 72" optional) Clean or "dirty" liquids Conductive liquids Municipal Industrial Irrigation GENERAL INFORMATION The complete lack of moving parts of the EX100/200-Series insertion flow sensor is the source of its reliability. Brass and stainless steel models withstand a variety of temperature, pressure, and chemical conditions. The EX-Series has no rotor to stop turning in dirty water and there are no bearings to wear out. Like all magmeters, when used in chemical injection applications, these meters should be installed upstream of the chemical line (or far enough downstream to allow complete mixing of fluids before the meter). A rapidly reversing magnetic field is produced in the lower housing. As the fluid moves through this field, a voltage is generated that is measured and translated into a frequency signal proportional to flow rate. This square wave signal can be sent directly to a PLC or other control or can be converted using any of the Seametrics family of indicators and converters. A modular system of electronics can be attached directly to the flow sensor or remotely mounted. The Seametrics FT400 series indicator provides full indication of rate and total, plus 4-20 ma output. The A055 provides blind 4-20 ma output, and the DL76 is a battery-powered data logger. Adapters mate with standard 1-1/2" (110/210) or 2" (150/250) FNPT threaded fittings such as saddles and weldolets which may be purchased either locally or from Seametrics. The EX150 and 250 include an isolation valve, allowing hot-tap installation, or installation and removal under pressure; a bronze ball valve is standard, with a 316 stainless steel valve option if needed. Reverse flow output and innmersibility are optional. 27 Provided / Distributed / Serviced By: Phone: (800) (513)

41 Seametrics Cable Strain Relief Cover or Electronics Module Housing Screw (connect ground to one) Powder-Coated Aluminum Housing Brass or 316 SS Shaft Compression Nut Adapter Fitting 1 1/2" Male NPT threads EX150/250 Sensor housing Electrodes and Cap 1...i_ Compression Nut & Locking Collar for easy adjustment 2" Adapter (removes to mount hat-tap machine) Valve assembly for hot-tap installation 2" Male NPT threads 3/4" tubing Low insertion force (typically no tool required) SPECIFICATIONS* Pipe Sizes Materials Shaft/Fitting Electrodes Electrode Cap Housing Valve Assembly (115/215 Only) 0-Ring (115/215 Only) 3- to 48" (up to 72" optional) 316 SS or Brass Hastelloy PVDF Cast powder-coated aluminum Bronze (stainless optional) with bronze ball valve EPDM Power F u l l Power Vdc, 250 ma Low Power Vdc, 40 ma average with 250 ma peaks Flow Range 0.28 to 20 ft/sec ( m/sec) Fitting Size Required EX110/21.0 EX150/ /2" FNPT 2F NPT Temperature Ambient 0 to 160 F(-17' to 72 C) Fluid 32' to 200' F (0" to 93' C) Pressure Minimum Conductivity Calibration Accuracy Output 200 psi (13.8 bar) 20 micrasiemens/cm -11-1% of full scale Square wave pulse, opto isolated, 550 Hz 0 20 ft/sec 6 ma max, 30 Vdc forward flow standard; reverse flow optional Empty Pipe Detection Software, defaults to zero flow *Specifications subject to change Please consult our webs ite tor current data ( Provided / Distributed / Serv,g1 By: Phone: (800) (513)

42 EX100/200-SERIES Insertion Electromagnetic Flow Sensor DIMENSIONS EX110 = 11-3/4 in. EX210 = 16-3/4 in. EX150 = 18-3/4 in. EX250 = 22-3/4 in. 2" Male NPT threads Adapter fitting with 1-1/2" Male NPT threads 2" Male NPT threads EX110 and EX210 EX150 and EX250 Flow Range (GPM) Nominal Pipe Size Min. Flow Max. Flow 3.89" a 25 1,762 a 44 3, , " , ,596 is , , , , , " , , , Provided! Distributed / Serviced By: Phone: (800) (513)

43 Seametncs ORDERING INFORMATION Sensor Only Description Size Sensor Material Options (110/210) Options (150/250) Sensor Only 1"- 12" pipe - EX110 Brass- B Brass Adapter Fitting 2' NPT SS Valve Assembly OH 12-40" pipe = EX Stainless = S SS Adapter Frtting 2" NPT= -02 Reverse Flow Output = -13 Reverse now Output Immersible- 40 Hot Top Mho:power Pickup iii -04 Low Power i- 40 3' - 17 pipe = EX3.50 Brass Adapter 1 Wz'BSP = " Extension (210/250 Series Only) = " pipe = EX250 SS Adapter 1W ESP = -24 Old Style Adapter 11/2" NPT =45 immersible =40 Low Power--SO 12" Extension ( Series Only)- -72 FT400 Series (External Power) Mounted on Sensor Description Size Sensor Material Options (111/211) Options (151/251) Rate & total Indicator with F1430 3"- 17 pipe iii EX.1_13 Brass - B Brass Adapter Feting 2' h PT SS Valse Assembly - -0E1 pulse &4-20 ma output FT pipe = E52/3 316 Stainless - 8 SS Adapter Fitting 2' NFT Reverse Flow Output externally powered (FT400 Reverse Flew Output = -3.8 Tamper Evident Kit = -32 Series) mounted on the FT440 3"- 12' pipe -, EX115 Brass Adapter 11/2" SSP -,23 Non-resettable Total -44 lesser. FT ' pipe = E1(213 IS Adapter 11/2' BSP ii 44 12" Extension (ztopso Series Only) Tampa Evick3nt Kit = -32 Dual Relay Output = -es Not Tap Old Style Adapter 1W NPT- 45 Hinged Display Cover i -126 FT4303'- 17 pipe = EX163 Low Power = -50 FT ' pipe - E5253 Nonresettable Total Extension (210/250 Series On i--72 P14403" -17 pipe = EX156 Dual RelmfOutput =44B P " pipe -, EX255 Hinged Display Cover = -126 A055 Mounted on Sensor Description Size Sensor Material Options (112/212) Options (152/252) Blind 4-20 ina analog 3"- 12" pipe = Brass" B Brass Adapter Frtting 7 NPT = -02 Standard Power, laill 4-pin Connector =45 transmitter (1105.5) mounted 12-40" plpe = E Stalnl ess = S SS Adapter Ming 2" NPT = SS Valve AssLmibly = -OS on the sensor. Standard Power, LAM 4-ph Connector -.08 Reverse Flow Output..1.5 Mot Tap Reverse Flow Output = -15 Low Power = 450 3" - 17 pipe = EX1A2 Brass Adapter 1 VilISP = ' Extension (210/250 Series OW " plpe EX252 SS Adapter 1 1/2"13SP.. 44 reogtronlcssedes4 5-Pln Connecta Cia Style Adapter 11/2" NFT =411 Low Power ii ' Extension (210/250 Sores Only] Royhonics Series-A 5-1,5n Connecta = -106 D176 Mounted on Sensor Description Size Sensor Material Options (116/216) Options (156/256) Date logger MOB) mounted on the sensor. 7-12' pipe. EXU " pipe.illot216 ilot Tap 3" - 12' pipe - EX " pipe = E1(2845 Brass ii B 316 Stainless - S Brass Adapter rating 2' NPT. -02 SS Adapter Fitting 2" NPT Reverse Flow Output = -15 Brass Adapter 1 1/2" BSP -23 SS Adapter 1W BSP Tamper Evident Kit = -32 Old Style Adapter 1½" N PT iii 45 Low Power = -SO 17 Extension (210/2SO Series On I., Valve Assembly --08 Reverse Flow Output Tamper Evident KII= -32 Low Power " Extension i2.10/250 Series Only) PD10 Mounted on Sensor Description Size Sensor Material Options (118/218) Options (158/258) Purse Divider (P010) 1"- 17 pipe =11118 Brass = B Brass Adapter Fitting 2 NPT = -02 MI Pump 4-pin Connecta mounted on the sons r " plpe. E Stalni s ii S SS Adapter Fitting 2" NPT Valve Assembly --06 LN1I Pump 4-pin Connector. -06 Reverse Flow Output = -15 Not Tap Reverse Flow Output = FL Cable for LFA I Connector = pipe = EX1.58 Brass Adapter 11.5" BSP = -23 Low Power = " pipe - E1(258 SS Adapter 1W BSP " Extension 210/250 Series Only) -72 Oki Style Adapter 1½" N PT =36 RoytroniesSerlesA 5-Pln Connector = Ft. Ca ble for LNII Connector- 47 Low Power ' Extension (210/250 Sedes Only) --72 FroyIronicsSeries.45-Pln Connecta i -106 'Total UnItS must be specified at time of otter "'Requires appropriate fitting. Provided / Distributed / ServNul By: Meters I Controls (Equipment I Service Phone: (800) (513)

44 IP800-SERIES Insertion Paddlewheel Flow Sensor FEATURES Low-friction, long-life jewel bearings One moving part Fully field-repairable Choice of materials for compatibility with variety of chemicals Fits 1/2" to 8" pipe Fixed depth in fitting ensures proper placement in pipe APPLICATIONS Industrial water/wastewater treatment Cooling water monitoring Industrial fluid control Chemical proportioning GENERAL INFORMATION The IP800-Series are impeller (or "paddlewheel") insertion meters designed for use with a wide variety of liquids in pipe sizes 1/2" to 8". Sensors are available in brass, 316 stainless steel, PVC, and polypropylene. Bodies are machined from a solid rod for maximum precision. High-quality jewel bearings and nickel-bound tungsten carbide shafts are used for extreme low friction and long life. Low-flow performance is good, although other Seametrics flow meters are recommended where extremely low flows are being measured. The rotation of the rotor is detected by a non-drag Hall-effect sensor. Output is a current-sinking pulse, which can be sent long distances (up to 2,000 feet) without a transmitter. This signal can be connected directly to PLC's, counters, and computer cards, as well as a variety of Seametrics controls and displays. 31 Seametrics IP meters are ideal for chemical proportioning applications. If no display is required, a simple divider such as the PD10 provides adjustable pump pacing. For rate and total display, the F1450 (battery powered) or FT440 (loop powered) flow indicator can be mounted directly on the 1P800-Series meter, or remotely on a wall or panel. The A055 blind analog transmitter can be used to convert to a 4-20 ma output. IP meters are also compatible with the DL76 data logger and FT520 batch processor. The 1P800-Series require special fittings that ensure correct depth placement in the pipe. Fittings come in a variety of materials for compatibility with specific applications. Tee fittings are individually wet-calibrated at the factory and marked with the K-factor (pulses per gallon). Saddle fittings must be field-installed on the pipe and do not come wet-calibrated. K-factors for saddles are base a ctory-testi ng. Provided / Distributed / Serviced By: Phone: (800) (513)

45 Seametncs Cover or Optional Control/Display Housing Screw (connect ground wire to one) Cable-Seal Strain Relief Lower Housing (optional) High Pressure Retaining Slot (for U-Clip) For easy installation at correct depth setting 0 -Ring Jewel Bearings for superior low-flow performance Rotor SPECIFICATIONS* Materials Sensor Body Rotor Shaft Bearings 0-Ring Rotor Pickup Maximum Pressure Brass, 316 Stainless Steel, PVC, or Polypro PVDF Nickel-bonded tungsten carbide (Ceramic optional) Ruby jewel EPDM (Viton optional) GMR (Giant Magnetoresistive) Sensor Brass 316 SS PVC or Poiypro (See Pressure vs. Temp. Chart) 200 P81(14 bar) 200 PSI (14 bar) 175 PSI (12 75 F High Pressure Not Available 400 psi (28 bar) Not Available Temperature 200 F(93' C) 200' F(93" C) 130' F(55' C) Flow Range ft./sec. Accuracy +/- L5% of full scale signal Hall effect current sinking pulse Power 6-24 Vdc, 2 ma Maximum Current 20 ma Cable #22 AWG, 3 Cond, 18 foot (maximum 2000' run) *Specifications subject to change Please consult our webs ite for current data ( Provided / Distributed / SerIgl By: Meters I Controls [Equipment I Service Phone: (800) (513)

46

47 Seametncs ORDERING INFORMATION Sengor On I, Sensor Only Description Size Sensor Material Options = IP810 4' - 8'.. IP820 Brass - B 316 Stainless Steel - S PVC = P Polypro. Y FT400 Series (External Power) Mounted on Sensor Rotor wtth Ceramic Shaft, Pr/OF, Krug = -01 Micropower Pickup =.04 Standard Power, LMI 4-pin Connector = 48 Standard Power, Sesrnetrics Control Connector = -07 immersiblity = -40 a13on400-ring = -80 Roytronics Series A Pump 5-pin Connector = -106 "'High Pressure (Stainless Only) = -HP Description Size Sensor Material Options Rate & total Indicator with poise & 4-20 me output. externally powered (m o o Series) mounted on the SC MO!. FT430 r" ii 3' = IP513 FT430 4'- 8' =1P623 FT440 1.' - 3' = IP815 FT440 4' - r = IIP825 Brass.- B 316 Stainless Steel = S PVC.. P Polypro = Y Rotor with Ceramic Shaft PVDR Kynar = -01 Tamper Evident Kit = -32 Vitale 0-Ring = 40 Non-resettable Total = 44 Dual Relay Output = -98 Hinged Display Cover A055 Mounted on Sensor Description Size Sensor Material Options Blind 4-20 ma analog transminer (4055) mounted an the sensor. 1" IP812 4' - 8' = IP822 B-ass -. B 316 Stainless Steel = S PVC = P Polypro - Y Rotor with Cerarric Shaft PVDF Kynar = 41 Standard Power, LMI 4-pin C,onnectcr =.08 Mem 0-Ring = 40 Roytronics Seres A Pump 5-pin Connector= -toe High Pressure (Stainless Only) = -HP FT450 (Battery Power) Mounted on Sensor Description Size Sensor materlai Options Rate & total Indicator with pulse & 4-20 ma output battery powered (FT450) mounted on the sensor. 1.'- 3" = IP817 4'- 8" = IP827 Brass = B 318 Stainless Steel = S PVC. P Polypro = Y Rotor with Ceramic Shaft PVDR Kynar = 41 Termer Evident Kit = -32 Wont 0-Ring = 40 Non-resettable Total = -84 Hinged Display Cover = -126 "High Pressure (Stainless Only) = -HP DL76 Mounted on Sensor Description Size Sensor Material Options nets logger (DL76) mounted on the sensor. 1" -3 = IP ' - IP826 Brass = R 316 Stainless Steel. S PVC = P Polypro = Y Rotor wtth Ceramic Shaft, PVDF, Kynar = -01 MIcrepower Pickup = -04 Tamper Evident Kil = -32 Vitore0-RIng = -60 'High Pressure rstainless Orgy) = -HP P010 Mounted on Sensor Description Size Sensor Material Options Pals. DIvIdm {P010) mounted on the sensor. t ' - 1P1318.4'. S' - 11,828 Brass -= B 316 Stainless Steel - S PVC = P Polyp = Y Rotor wfth Ceramic Shaft, PVDF, Kynar = -01 LMI Pump Connector = FL Cable for RAI Comector.-37 Vrtorrei 0-Ring = 40 Roytronks Series A Pump 3-pin Connector = 408 *High Presage (Stainless Only) = -HP Provided / Distributed / ServN41 By: Meters I Controls [Equipment I Service Phone: (800) (513)

48 IP100/200-SERIES Insertion Paddlewheel Flow Sensor FEATURES Wide flow range One moving part Hot tap available Modular electronics compatible Easily depth adjustable for 3-40" pipe APPLICATIONS Clean water Large pipes Aquariums, water parks Water & wastewater monitoring GENERAL INFORMATION The IP100/200-Series are adjustable depth insertion paddlewheels that come in brass, PVC or 316 stainless models to fit 3" to 40" pipe. Adapters mate with standard 1-1/2" (110/210) or 2" (150/250 or PVC110/210) NPT threaded fittings such as saddles and weldolets which may be purchased either locally or from Sea metrics. Ruby bearings and a non-drag Hall-effect sensor give these meters the widest flow range of any of the paddlewheel types. A sensor detects the passage of miniature magnets in the six rotor blades. The resulting square-wave signal can be sent for hundreds of feet over unshielded cable without a transmitter and connected directly to many PLC's and other controls without any additional electronics. 35 If desired, a modular system of electronics can be installed directly on the flow sensor or mounted remotely. The FT450 (battery powered) or FT440 (loop powered) flow indicator provides digital rate and total display, as well as programmable pulse output; the F1440 also provides a 4-20 ma analog output. If a display is not required, the A055 provides 4-20 ma analog output, and the PD10 provides a programmable pulse for pump pacing. The "hot-tap" models (IP150/250) can be installed or serviced withoutshutting down the line by means of a 2" full-port isolation valve that comes with a nipple for installation on the pipe fitting. In most circumstances, no special tool is required. Provided / Distributed / Serviced By: Phone: (800) (513)

49 Seametrics Modular electronics (optional) rate/total/pulse/4-20 ma blind 4-20 transmitter pulse divider 18 Foot Cable Rugged cast aluminum housing Compression nut for easy adjustment, secure locking Adapter fitting with 1-1/2" NPT threads 3/4" diameter tubing for low insertion force 2" Adapter removes to mount hot-tap machine Full-port 2" ball valve for sensor removal L o c k i n g collar Adapter fitting with 2" NPT threads IP110/210 IP150/250 Rotor housing Removable Jewel bearings Rotor SPECIFICATIONS* IP150/250 PVC Pipe Size IP110/150 IP210/250 3" to 12" (50-300mm) 12 to 40" ( mm) Sensor Materials Housing Sensor Body Rotor Shaft Bearings Hall Effect sensor, 12 Vdc current sinking pulse Cast aluminum Brass, PVC or 316 SS PVDF (Kynar) Nickel-bound tungsten carbide (zircon ia ceramic optional) Ruby jewel IP1.10/210 (Brass/SS) IP150/250 (Brass/SS) PVC 110/210/150/250 isolation Ball Valve None Bronze (3165S optional) (PVC uses gate valve) Fitting Size Required 1.5" FNPT 2" FNPT 2" FNPT Flow Range feet/sec (0.1-9 meter/sec) Accuracy +/- 1.5% of full scale Maximum Temperature Brass/SS 200' F (93* C) PVC 130' F (55' C) Maximum Pressure Brass/SS PVC insertion Force Power 200 psi (14 bar) 150 psi (10 bar) 0.44 x pressure in pipe 5-24 Vdc, 1.5 ma ( Vdc with -04 option) Cable #22 AWG 3-con, 18' (6m); 2,000' (650m) maximum cable run Specifications subject to change. Please consutt our website for the most current data ( Provided I Distributed I ServNgl By: Meters 1 Controls [Equipment I Service Phone: (800) (513)

50 IP100/200-SERIES Insertion Paddlewheel Flow Sensor DIMENSIONS 3 853' crn 1,110 (Brass/S5) = Pi la Tvg =1 Ler 3O.1601) 1P210 (Brass/SS) = 153r(40 34 cm) P 210 (PVC{ =i6ar (42.88 on} (11.88" PVC) (16.88" PVC) IP150 (eras/ss) = 17.75" (46.09 cm) IP150 PVC) = (47.53 cm) IP250 Or es/ss) = 21 75*( P250 (PVC) = (70) (1 8 /5" PVC) (22.75" PVC) HOT TAP INSTALLATION Insertion and removal under pressure is possible due to the 2" full-port isolation valve, which comes with a nipple for installation on the pipe fitting. If it is necessary to do the initial installation under pressure, any standard hot tap drilling machine with 2" NPT adapter, such as a Transmate or a Mueller, can be used. Ordinarily, it is not necessary to use an installation tool, since the smalldiameter tube can be controlled by hand at all but the highest pressures. HOT TAP REMOVAL FLOW RANGE 3" 4" 6" 8" so- 1.2" sr 24" 30^ 36' 40" OFMNIn (.31t/sec) ,174 Mt. Min (.09m/sec) GPM Max (3011/86c) WM Max49.1m/aec) Approximations based on Schedule 40 pipe. 37 Provided! Distributed / Serviced By: Phone: (800) (513)

51 Seametncs ORDERING INFORMATION Sensor Only Description 1 Size Material Standard Options Hot Tap Options Sensor Only. T- 32" -1P110 12'- 40' = IP210 Hot Tap 3' - 12 = IMMO 11'- 40' iri 1P250 Brass SS = tit PVC - P RON with COW* Shat F'VDF. Kynar = -01 Brass Adapter 1 W BSP = -23 BrassAdanter Fitting 2" NPT = -02 S S Adapter I W BSP = -24 SS Adapter Fitting 2" NPT -02 O n Styie Adapter 1 W NPT.35 krfooporver Pickup = -04 k o r d e r s i b i e = -40 Standard Power1M14-pin Connector = ' Extension (210(2E6 Sepias Only) =-72 Sind Power, Searnsans C71Connector = -07 Boyle:fins Serns-A 5-Pin Correct( = -106 Hot( with Ceramic Shot PVDF, Kynar --01 Mir:avower Pickup = -04 Standard Power, LMI 4-ph i Connects. -06 Standard Power, Searnehrics Control Connrotor = SS Valve Assembly = -OR Immersible = ' Extension ( Series Only) = -72 Ftoykonics Series-A 5-Pin Connector F1400 Series (External Power) Mounted on Sensor Description Size Material Standard Options Hot Tap Options Rate & total Indlcator wfth pulse & 4-20 ma output, externally powered (P1400 Sor185) mounted on the sensor. rnsao I"" ip013 F1430 4" " 8- ' =IP828 FT430 3" IP113 FT ' = IP= FT440 S." - 3' - WS15 F1440 4' - 8' = IP525 FT") 3" Pil5 F ' = IP215 Flat Tail ' - 12"'- Ihi_sa "- 40.' -IP "- 12"- IP1SS ' = IP/55 Brass = SS= S PVC P Finer with Coen* Sbat PVDF, Kynar = -Cl On Style Adopter 11,4" NPT= 45 Brass Adapter Filling 7 NFT = -02 Nonnasettalle Total = -64 SSAriapter Frtting 2' NPT = ' Extarabn (210(250 Senes Cnly) =-72 Brass Adapter 1 W BSP = -23 D t t a l Reny Oulput = -88 SSAdapter 1 W. BSP = -24 H i n g e d Display Cover = -126 larnper Eirldent Kit = -32 Rotor with CerarrOc Shaft., PVDF, Kynar = SS ValtioAssom* = -08 Nomresetlable Total = ' Exlaisen ( Series Oniy) = -72 Duel Relay Output = -96 Hinged Disotay Cover = -126 A055 Mounted on Sensor Description Size Material Standard Options Hot Tap Options Bend 4-20 rna analog transminer (A065) mounted on the sensor. 3'- 12" = IP112 :..2' 40' ii P212 Hot Tap 3'- 12" -11,152 12"- 40'"' IP252 BraS5 = SS - S PVC = P Rotor with Corarnid Shaft, Pt/Of, Kynar- -01 SS Adaptor 1 l'y' EISP = -24 Brass Adapter Fitting 2 NPT = -02 O n Styie Adapter 1 14" NPT = -35 SSAdapter Fitting 2' NPT = " Einanslcn (21025a Series Orly) = -72 Standard Power L pin C,on= -06 Reynolds Series-AS-Pin Connector = -106 Brass Adapter 11,4* BSP = -23 Rota( y4th Carona Shaft PVElF. Kyrof Standard Power, LMI 4-pin Connector = SS Valve Assembly = -08 No VaNa Assembly =0$ 12" Exbonsbn ( Series Only) = -72 Royronim Series-iA 5-Pin Connector = -106 FT450 Mounted (Battery Power) on Sensor Description Size Material Options Hot Tap Options Rate & total Indicator with puts. & 4-20 ma output. battery powcued F1450)( mounted on the sensor. 7'- 12'- 1P117 12'- 40'- 1P217 Het Tap 7'- 12" -, I P157 12' 40" = IP257 Brass- B 3165S - S PVC = P Rotor wit] Ceramic Shaft, PVDF, Kynar = -01 Cid StyleAdapier I t.,;" NPT -35 Brass Adaptor Fitting 2 NPT = -02 Non-Resettible Total = 44 SS Adaplo Fitting 2" NPT= Extension ( Series Only)= -72 Brass Adapter 1 W BSP =.23 H i n g e d 06play Carer it -126 SSAdapler 1 W BSP = -24 Tainpor Evident Kit = -32 Rotor will Ceramic Shaft, RIX, Kynar SS VaNe Assembly = 48 Tamper Evident Kit = -32 Nowesettakie Total = Extension ( Series Only) = -72 Pinged Display Cover = -126 DL76 Mounted on Sensor Description Size Material Options Hot Tap Options Data logget (DI-76) mounted on the sensor. 3' - 12' = Pus.2" - 40'- 1P216 Hot Tap 3'- 12" IP118 17'- 40' - 1P216 Brass = B S PVC -- P Rater wth Csramic Shak PVDF, Kynar = -01 SSA:beta, 1 W BSP =24 Brass Adapter Riling 2" NPT = -02 T a m p e r Evident KB- -32 SS Adapter Fittng 2" NPT = -02 O l d Style Adapter 1 W PT= -36 Brass Adapter 1 )1' BSP = -23 Rao( with Coarric Shaft, PVDF, Kynar = SS Vaiye Asserri* = -08 No Valve Assembly = -09 Tamper Evident Kit = ' Enensice ( Senes Only) = -72 PD10 Mounted on Sensor Description Size Material Options Hot Tap Options Pulse Divider (PD10) mounted on the sensor. 7'- 17'- PUB 12"- 40" -(P212 Hot Tap 3'- 12" = IP158 12'- 40'- IP258 Brass = S PVC = P Rotor yytth Canonic Shaft, PVDP. Kynar = -01 SS Adapter1 14' BSP = -24 Beare Adapter Fitting 2 NPT = -02 O n Style Adopter 114" NPT = -35 SS Mortar Fitting 2' NPT = Ft. Cable tor LMI Connector = -37 LM1Pisrp 4-pin C,onrector = -08 R o y i r t r i m Serise-A 5-Pin Comedic( = -108 Brass Adapter I 15" BSP = -23 *Consult factory for suitable appl cations **Requires appropriate fitting. t Total Unite must be specified at tirne of order Rotor with Comic Shaft, PVDF, Kynar = 41 LMI Pump 4-cin Conneclor = VaheAssemi* = -011 No ValVe Assembly = " Extension ( Series Only). -72 Roytronics Series-A 5-PIn Connector = -106 Provided / Distributed! ServNal By: Meters I Controls [Equipment I Service Phone: (800) (513)

52 TX800-SERIES Insertion Turbine Flow Sensor FEATURES Low-friction, long-life jewel bearings One moving part Field repairable Choice of materials for chemical compatibility Fits 1-1/2" to 8" pipe Fixed depth in fitting ensures correct depth in pipe APPLICATIONS Water treatment Industrial wastewater treatment Cooling water monitoring Industrial fluid control GENERAL INFORMATION The TX800-Series are insertion turbine meters designed for use in 1-1/2" to 8'' pipe. High-quality jewel bearings and precision shafts ensure long life and low friction. Available in 316 stainless steel, brass and PVC, sensor bodies are machined from solid rod for maximum low-flow performance. The TX800- Series use special fittings that ensure ease of installation and correct depth setting in the pipe. Seannetrics TX800 meters are ideal for chemical proportioning applications. If no display is required, a simple divider such as the PD10 provides adjustable pump pacing. For rate and total display, as well as pump pacing, an FT400 series flow indicator can be mounted directly on the TX800-Series, or remotely on a wall or panel. The FT450 offers a batteryoperated rate/totalizer where power is not available. The rotation of the turbine is detected by a non-drag Hall-effect sensor. Output is a pulse-type square wave, which can be sent long distances (up to 2,000 feet) without a transmitter. This signal can be connected directly to Seametrics controls and displays, as well as PLC's, counters, and computer cards. 39 Provided / Distributed / Serviced By: Phone: (800) (513)

53 Seametrics Optional meter mounted electronics Rate/total display Battery rate/total 4-20 ma blind transmitter Pulse divider Cable-Seal Strain Relief U-Clip Insertion Point 0-Ring Fitting Fixed depth in fitting ensures correct depth placement in Pipe Bearing Housing Rotor SPECIFICATIONS* Materials Body Rotor Assembly Bearings PVC, brass or stainless steel PVDF rotor/carbide shaft Ruby jewel 0 -Ring EPDM (Viton optional) Rotor Pickup GMR (Giant Magnetoresistive Sensor) Maximum Brass 316 SS PVC (See Pressure vs_ Temp. Chen) Pressure 200 psi (14 bar) 200 psi (14 bar) 175 psi (12 bar) at 75* High Pressure Not Available 400 psi (28 bar) Not Available Temperature 200 F (93* C) 130' F (55 ' C) at 0 p.sl Flow Range Calibrated Accuracy Signal Power Cable 0.5 to 30 ft./sec. ( meter/sec) +/- 2.5% of full scale Current sinking pulse, 20 ma max, 30 Vdc max (Micropower option: Pulse output swings between supply voltage and 0 Vdc) 6-30 Vdc (iii 8 ma (Micropower option: VdcCO 0.3 ma max) 22 AWG, 3 Con, 18'; 2000 max run *Specifications subject to change. Please consult our website for the most current data { Provided / Distributed / Servisel By: Phone: (800) (513)

54 TX800-SERIES Insertion Turbine Flow Sensor DIMENSIONS P R E S S U R E VS. TEMPERATURE (PVC) NOTE: Top Housing Optional " - U.U3 En P.S.I. 100 TX810 = 7.5" 1995cm TX820 = 8.5" cm I.75" I 1.P. ran " 1553 CM TOP OF TEE 50 60" 70* K r 90' 100' 110' 120' 130" Fahrenheit FLOW RANGE (in Gallons Per Minute) 11/2" 2" ' Min Max FLOW RANGE (in Liters Per Minute) 11/2-2" 3" 4" 6" 8" Min Max AVAILABLE FITTINGS 2_ Tee Saddle Weld Braze Sweat Tee Bronze 1-1/2-4" 3"-8 x 3"-8" 1-1/2'-4' A PVC TEE FITTING PVC 1-1/2"-2" 3"-8" x X X Stainless Steel 1-1/2"-2" 304SS 3"-8" 316SS Carbon Steel 1-1/2-2 X 3"-8" X X Ductile Iron x 3"-8" x X X x X 41 Provided / Distributed / Serviced By: Phone: (800) (513)

55 Seametncs ORDERING INFORMATION Sons, Only. Sensor Only Description Size Sensor Material Options 1."". 3" = TXBIO 4' - Er - TX820 Brass = P 316 Stainless Steel - S PVC - P FT400 Series (External Power) Mounted on Sensor Micropower Pickup = 44 LMI Pump Connector = -06 Searnerics Control Connecter = -07 iminersibility = -40 Vitor00-Ring = -60 Roytroricse Series A Pump 5-pin Connector = -106 High Pressure (Stainless Only) = -HP Description Size Sensor Material Options Rate & total Indicator wtth pulse & 9-20 ma output, externally powered (F7400 Sodom) mounted an the sensor "" FT430 4" - 8" F7440 1," " 8" Brass., B 316 Stainless Steel - S PVC = P Tamper Evident Kg = -32 Vrton 0-Ring = -60 Nonteserlable Total = -64 Dual Relay Output = -98 Hinged Display Cover= -126 High Pressure (Stainless Orgy) = -HP A055 Mounted on Sensor Description Size Sensor Material Options Blind 4-20 ma rinsing transmitter (405S) mounted on the sensor ' = ' - r = TX822 Brass = B 316 Stainless Steel = S PVC,- P I MI Pump Connector = -08 ',Atone 0-Ring = 40 RoytrOniCse SeriesA Puny 5-pin Connector = -106 High Pres.sure (Stainless Orgy) = -HP FT450 (Battery Power) Mounted on Sensor Description Size Sensor Material Options Rate & total Indicator with pulse & 9-20 ma output. battery powered (7450) mounted en the sensor. l'''' - 3" r " 8" Brass - B 316 Stainless Steel - 5 PVC = P Tamper Ewlent Kit = 32 Mk:MOO-Ring = 40 Nonresettable Total = -64 Hinged Display Cover **High Pressure (Stainless Only) = -HP DL76 Mounted on Sensor Description Size Sensor Material Options Data logger (01_76) mounted on the sensor. 14' 3" =IMMO 4-8' = TX626 Brass = B 316 Stainless Steel = S PVC P TaMper Evident Kit = -32 Mtn 0-Ring = -60 **High Pressure (Stainless Only) = -HP PD10 Mounted on Sensor Description Size Sensor Material Options Pulse Divider (P0101 mounted on the sensor. It". - 3' = USIA tr - 8' = TX112/1 Brass = P 3143 Stainless Steel = S PVC -P LW Pump Connector = Ft Cable for LAM Comeotor = -37 Woo/DO-Ring = -60 Roytronics Series A Pump 5-pin Connector = -106 High Pressure (Stainims Only) = -HP 'Consult factory for surtable applications **Requires appropn ate fitting. Provided / Distributed / Seryjsgi By: Meters I Controls [Equipment I Service Phone: (800) (513)

56 TX100/200-SERIES Insertion Turbine Flow Sensor FEATURES Wide flow range One moving part Hot tap available Modular electronics compatible Easily depth adjustable for 3-40" pipe APPLICATIONS Clean water Large pipes Aquariums, water parks Water & wastewater monitoring GENERAL INFORMATION The TX100/200-Series are adjustable depth insertion turbines that come in brass or 316 stainless models to fit 3" to 40" pipe. Adapters mate with standard 1-1/2" (110/210) or 2" (150/250) FNPT threaded -fittings such as saddles and weldolets which may be purchased either locally or from Seametrics. Ruby bearings and a non-drag pickoff give these adjustable insertion turbine flow sensors a wide flow range and long life. A sensor detects the passage of miniature magnets in the rotor blades. The resulting square-wave signal can be sent for hundreds of feet without a transmitter, over unshielded cable. This signal can be connected directly to many PLC's and other controls without any additional electronics. 43 If desired, a modular system of electronics can be installed directly on the flow sensor or mounted remotely. The FT450 (battery powered) or FT440 (loop powered) provides digital rate and total display, as well as programmable pulse; the FT440 also provides a 4-20 ma analog output. The A055 is a blind analog (4-20 ma) transmitter. Programmable pulse for pump pacing is available with the PD10. The "hot-tap" models (TX150/250) can be installed or serviced without shutting down the line by means of a 2" full-port isolation valve that comes with a nipple for installation on the pipe fitting. In most circumstances, no special tool is required. Provided / Distributed / Serviced By: Phone: (800) (513)

57 Seametrics Modular electronics (optional) rate/total/pulse/4-20 ma blind 4-20 transmitter pulse divider 18 Foot Cable Rugged cast aluminum housing Compression nut for easy adjustment, secure locking Adapter mates with 1-1/2" FNPT threaded fitting Rotor housing Removable Jewel bearings Rotor TX110/210 3/4" diameter tubing for low insertion force 2" Adapter removes to mount hot-tap machine Full-port 2" ball valve for sensor removal Adapter mates with 2" FNPT threaded fitting TX150/250 Locking collar SPECIFICATIONS* Power Source Standard Mlcropowered (-04 Option) Supply Voltage/Current 6-40 Vdc/< 2 ma Vdc/ Vdc Sensor Type Magnetoresistive Magnetoresistive Output Current Sinking Pulse Current Sinking Pulse Sinking Current 100 ma max 2 ma max External Pull-up Resistor 3-40 Vdc <Supply Voltage Pipe Size MILO/1SO TX210/250 3" - 12" (50-300mm) 12"- 40' ( mm) Materials Housing Cast aluminum Sensor Body Brass or 316 SS Rotor PVDF standard Shaft/Bearings Nickel-bound tungsten carbide/ruby Isolation Valve TX.110/210 TX.1.50/250 None Bronze (31655 optional) Fitting Size Required 1-1/2" FNPT 2" FNPT Flow Range Accuracy feet/sec ( meter/sec) +/-1.5% of full scale Maximum Temperature 200" F (93" C) Maximum Pressure Insertion Force 200 psi (14 bar) 0.44 x pressure In pipe Cable #22 AWG 3-con, 18' (6m); 2,000' (650m) maximum cable run *Specilkations subject to change. Please consult our webslte for the most current data ( Provided I Distributed I Serv441By: Meters I Controls [Equipment I Service Phone: (800) (513)

58 TX100/200-SERIES Insertion Turbine Flow Sensor DIMENSIONS ce TX110 = 11.5 TX210 = 16.5 TX150 = 18.5 TX250 = HOT TAP INSTALLATION H O T TAP REMOVAL Insertion and removal under pressure is possible due to the 2" full-port isolation valve, which comes with a nipple for installation on the pipe fitting. If it is necessary to do the initial installation under pressure, any standard hot tap drilling machine with 2" NPT adapter, such as a Transmate or a Mueller, can be used. Ordinarily, it is not necessary to use an installation tool, since the smalldiameter tube can be controlled by hand at all but the highest pressures. FLOW RANGE (Gallons Per Minute) Pipe Size 3" 4" 6" Er, 10" 12" 16" 18" 24" 30" 36" 40" Min ,100 1,585 1,960 Max ,190 2,700 4,680 7,370 10,470 16,520 20,900 37,600 62,505 87, ,500 Approximations based on Schedule 40 pipe. 45 Provided / Distributed / Serviced By: Phone: (800) (513)

59 Seametncs ORDERING INFORMATION Sensor Only Description Size Material Standard Options Hot Tap Options Sensor Only. 3". 12' = TX110.ri, - B Brass Adapter Rbrig 7 NPT = -02 B r a s s Adapter 1W BSP- -23 Bidireobonal e.4)3 12"- 40" - TX210 11,. -.,---i -S SS Adapter Fling 2" NPT = -02 S S Adapter 1 W BSP = -24 tufranpower Pickup= -04 Kidreclional = -03 D i d Style Adager 1 'A NPT = -35 Standard Power, LMI 4-cin Connector = 46 Hot bp Mbropower Pickup= -04 I m m e r s i b l e = -40 Standard Power, Semiotics argrol Connector = -07 3"- 17 = 7X150 Standard Power, LMI 4-pin Connector = " Extension (210/250 Series Only) = SS Valve Assembly = "- 40" Shd Power, Searnelrizs CC Connector = -07 ROylronios StiSies-A 5-Ph Connector = -106 Immersible = Bid:irides) (210/260 Series ONO= -72 Reybonins Series-A 5-Ph Conneclor = -106 F1400 Series (External Power) Mounted on Sensor Description Size Material Standard Options Hot Tap Options Rate 9 soul FT430 3' 12',1X113 Brass B Brass Adapter RION 2' NPT itt -02 ( A d St* Adapter 1 W NPT =.35 Bittrectionel = -03 Indicator with "3 12' 4Cr - TI" SS= S SS Adapter Fitting 7 NPT= -02 N o n -makable ToW = ValreAsserrely = -08 pulse & 4-20 Bidirectional = Extension (210/250 Series Only) =.72 No Valve Asserrtly= -09 F ' MA Output. FT :r,TX215 Brass Adapter 1 W BSP -23 D u e l Relay Output -88 Tamper Sildent Kg= -32 externally SSAdapter 1W BSP =-24 H i v e d Display Cover= -126 OM Style Adage( = -35 powered (p-r400 Series) WAIN, FT ,7X1S2 Tamper Evident Kit= -32 Nontesettable Tolal = -EA 17 Extension (210/250 Series Orly) = -72 mounted on F ' -7X.253 Dual Relay Output = 436 the sensor. F ' -7%155 Hinged Cispkiy Cover = -126 F "15256 A055 Mounted on Sensor Description Size Material Standard Options Hot Tap Options Blind 4-20 rna analog transmitten IA055) mounted on the sensor. 3" - 12" = 13X112 IT. 40"- nictz Rot le p 3" TX152 12"- 40' - TX252 Brass = B t. 5 Brass Adopter Fitthg 2' NPT = -02 S S Adapter 1 W BSP = -24 SS Adapter Fitting 2" NPT = 472 O k i Style Adapter 1 W NPT = -35 Borectional = Extension (210/250 Series Only) = -72 Sian:kin:I Poirter, LMI 4-pri Conneolor = -06 Roytronics Series-A 5.Pin Connector = -106 Brass Adapter 1 W BSP = -23 Bidirectional =43 Standard Power. LMI 4-phi Connector = VaNe Assembly = -08 No Vattra Asserrbly = Extension (210e250 Series Only) --72 RoyStrics Seties-A 5-Pin Connector =.106 Fr450 (Battery Power) Mounted on Sensor Description Size Material Options Hot Tap Options Rate & total Indicator with pulse & 4-20 rna output; battery potse red (F1450) mounted on the sensor. 3"- 12" = TX ' - 40".-TX.M.7 Nut Tap 3". 12"- TX " i. T5257 Brass = B 316 SS - 5 BrassAd,apter Fitting 2' NPT = -02 T a m p e r Evident a = -32 SS Merger Fining 2' NPT =42 O l d StyleActsprer 1 14" NPT- -35 BdinrAional --03 N o n - R e s e t l a b l e Total = 434 Bia,,,sAdapter 1 W BSP.., Extension ( Series Onhi) = -72 SS Actegar 1W ESP --24 H i n g e d Display Cover -126 Bidirececnal = SS Valve Assembly = -08 No Valve Assembly --09 Tamper EWdent Kt rs.32 Non-resetlable Total Extenson (210/250 Setts Only) = -72 Finged Display Cava- = -126 DL76 Mounted on Sensor Description Size Material Options Hot Tap Options Data loggor (0176) mounted on the sensor. 3"- 12" = TX ". 40" Hot Tap 7-12" -i TX ' it Brass = B 316 SS - S Brass Adapter Fitting 2" NPT = 02 S S Adapter 1 'A* &SP = -24 SS Adapter Fiero 714PT= -02 T a m p e r Evident 10t= -32 Bidirectional = -03 O l d Style Adder 114" NPT= -35 Brass/Wager 11,4"13SP = -23 PD10 Mounted on Sensor Etitirecilional = Valve Assembly = -08 No Valvis Assembly = -09 Tamper Eviient Kil = Eidansicn (210/250 Series On yi = -72 Description Size Material Options Hot Tap Options Purse Divider (P010) mounted on the sensor. 3"- 12" iii TX "- 40' Hot Tap 3"- 12" - TX158 12"- 40" Brass SS - S FIX = P Brass Adapter Filling 2' NPT= -02 S S Adapter 114" BSP = -24 SS Adapter Fitting 7 NPT = -02 O l d SIO Adapter 1 'A" NPT =-85 Bidiectional = I FL Cade for LMI Connector = -37 LM I Pump 4-pin Connector --06 B o p -cities Series-AS-Phi Connector = -106 Brass Adapter 1 'A' BSP = -23 'Conseil factory kit suitable applicabons Requires appropriate fitting. it Total Units must be specified at time of order Iiiiiireciennal. -03 LM Pump 4-pin Connector = Vabre Assembly = -BB No Valvis Assembly = Cable kr UN Adapter = " Extension ( Series Only) = -72 Roylrorks Series-AS-Phi Connecbx = -106 Provided / Distributed / Servjggl By: Meters I Controls [Equipment I Service Phone: (800) (513)

60 MJ-SERIES Pulse Meter FEATURES Dry top multi-jet design Tolerates low quality water Simple pulse output Cold or hot water models APPLICATIONS Cooling tower chemical control Industrial water treatment Deduct metering Hot Water GENERAL INFORMATION MJ-Series meters use the multi-jet principle, which has been an internationally-accepted standard for many years. This type of meter is known for its wide range, simplicity, and accuracy in low-quality water. Seametrics offers cold or hot water models. The impeller is centered in a ring of jets, with inlet jets on one level and outlet jets on another. A gear train drives the register totalizer dials. For pulse output, one of the pointers is replaced by a magnet, which is detected by an encapsulated sensor attached to the outside of the lens. Pulse rate is determined by the dial on which the magnet is placed, and by the number of sensors (single or double). 47 Changing the pulse rate requires no special tools and can be done in the field. Mechanically, all MJ-Series meters are the same. The difference among *MJE./MJHE, *MJR/MJHR and *MJT/MJHT meters is in the sensor. MJE/MJHE meters use a solid-state, long-lasting Halleffect sensor, which requires power. It is su ited for use with Seametrics controls and metering pumps ([Ml for instance)that have sensor power. MJR/MJHR meters use a two-wire reed switch. They provide a dry contact closure and do not require power. MJT/MJ HT meters totalize only and do not have a sensor. *Note on Nomenclature: Meter names that include "H" are hot water models. Without the "H" = cold water models. Provided / Distributed / Serviced By: Phone: (800) (513)

61 Seametrics Available in cold or hot water models Either MJE/MJHE or MJR/MJHR sensor fastens to lens without removing top Calibration plug seal wire for tamper evidence Cast bronze body Union end couplings for easy service SPECIFICATIONS* Power 6 ma at 12 Vdc (MJE/MJHE only) Temperature Cold Water Model 105 ' F (40" C) max Hot Water Model 194 F(90' 0) max Pressure 180 psi operating Materials Body Cast bronze, epoxy powder coated inside and out Internals Magnet Engineered thermoplastic Alnico Accuracy Pulse Output +/- L5% of reading MJE/NUHE MJR/MJHR MJT/MJKT Sensor Hall-effect device Reed switch Totalizer only Max Current 20 ma 20mA n/a Max Voltage 24 Vdc 24 Vdc or Vac n/a Cable Length 12' (4 m) standard (2000' maximum run) Flow Rates (GPM) 3/4" 1" 14/2" 2' Minimum Maximum Speciftcatfons subject to change Pt ease consult our webslte for current data ( Provided / Distributed / Servjuid By: Phone: (800) (513)

62 MJ-SERIES Pulse Meter MJ-SERIES Pulse Meter DIMENSIONS Presure PULSE RATES 3/4" 1" 1-1/2" 2" Pulses per Gallon 20* 10 4t t 4 t 2* 2 ' 2* 2* Gallons 5* 5* 5* 5* per Pulse 50* 50* 50* 50* Cubic Feet per 5-k 5* 5* 5* Puke /4" 1." 14/2" 2" A (body) 7-1/2" 10-1/4" 11-3/4" 11-3/4" B (w/couplings) 12-5/8" 15-5/8" 17-5/8" 17-5/8" C (IPS thread) 1" 1-1/4" 2-2-1/2" D (NPT thread) 3/4" 1" 1-1/2 2" Cubic Meter per Pulse *These pulse rates available in MJR and MJHR dual reed switch meters only. -tth is pulse rate available in MJR and MJHR single reed switch meters only. FLOW RATES (GPM) 3/4" /2" 2" Minimum Maximum PRESSURE DROP CURVE /4" " " Rate of flow in gallons per minute (GPr Provided / Distributed / Serviced By: Phone: (800) (513)

63 Seametncs ORDERING INFORMATION MODEL SIZE PULSE RATE O P T I O N S Cold water, Reed switch = MJR 3/4" = -075 T*20 Pulse/Gal = 20P LMI pump connector = -06 Cold water, Hall-effect sensor = mje 1" t10 Pulse/Gal- lop Cold water, Totalizer only = MJT *4 Pulse/Gal = 4P Seametrics control connector = /2" = -150 *2 Pulse/Gal = 2P Hot water, Reed switch = MJHR = Gal/Pulse- 1G Hot water, Hall-effect sensor = MJHE *5 Gal/Pulse = 5G Hot water, Totalizer only le MJHT 10 Gal/Pulse = log *50 Gal/Pulse = 50G 100 Gal/Pulse = 100G 1 CF/Pulse = 1CF *5 CF/P = 5CF 10 CF/P 10CF 1 CM/P = 1CM 10 CM/P = 10CM 100 CM/P 100CM 1-3/4" Only *MJR/MJFIR Meters Only ACCESSORIES Pulse divider = P010 Pulse splitter = PS40 Pulse timer = P135 Provided / Distributed / Sento' By: Phone: (800) (513)

64 MJN-SERIES Pulse Meter FEATURES Dry top multi-jet design Tolerates low quality water Simple pulse output NSF61 APPLICATIONS Cooling tower chemical control Industrial water treatment Deduct metering t1s_fy\ codified to NSF/N181 Cl GENERAL INFORMATION MJN-Series meters use the multi-jet principle, which has been an internationally-accepted standard for many years. This type of meter is known for its wide range, simplicity, and accuracy in lowquality water. The Seametrics MJN-Series is NSF-61 certified. The impeller is centered in a ring of jets, with inlet jets on one level and outlet jets on another. A gear train drives the register totalizer dials. For pulse output, one of the pointers is replaced by a magnet, which is detected by an encapsulated sensor attached to the outside of the lens. Pulse rate is determined by the dial on which the magnet is placed, and by the number of sensors (single or double). Changing the pulse rate requires no special tools and can be done in the held. Mechanically, all MJN-Series meters are the same. The difference among MJNE, MJNR and MJNT meters is in the sensor. MJNE meters use a solid-state, long-lasting Hall-effect sensor, which requires power. It is suited for use with Sea metrics controls and metering pumps (LMI for instance) that have sensor power. MJNR meters use a two-wire reed switch. They provide a dry contact closure and do not require power. MJNT meters totalize only and do not have a sensor. 51 Provided / Distributed / Serviced By: Meters I Controls [Equipment I Service Phone: (800) (513)

65 Seametrics Either MJNE or MJNR sensor fastens to lens without removing top Calibration plug seal wire for tamper evidence Eco-brass alloy body Union end couplings for easy service k't\ SPECIFICATIONS* Power Temperature Pressure Materials Body Internals Magnet 6 ma at 12 Vdc (MJNE only} 105' F(40 C) max 150 psi operating Eco-brass alloy Engineered thermoplastic Alnico Accuracy Fittings Lead-free tail piece +/- 1.5% of reading Pulse Output Cable Length Flow Rates (GPM) Regulatory Sensor MJNE NUNR NUNT liall-effect device Reed switch Totalizer only Max Current 20 ma 20mA n/a Max Voltage, 24 Vdc 24 Vdc or Vac n/a 12' (4 m) standard (2000' maximum run) 3/4" 1" 1-1/2" 2" Minimum Maximum _ NSF61 *Speccations subject to change Please consult our website for current data ( Provided / Distributed / Servisid By: Phone: (800) (513)

66 MJN-SERIES Pulse Meter DIMENSIONS PULSE RATES Presur 3/4" 1" 1-1/2" 2" oat.11 A 20* Pulses 10 per 4t 4t 4-4 t Gallon 2* 2* 2* 2* Gallons 5* 5* 5* 5* per Pulse 50* 50* 50* 50* Cubic Feet per 5* 5* 5* 5* Pulse /4" 1" 1-1/2" 2" A (body) 7-1/2" 104/4-11-3/4" 11-3/4" B (w/couplings) 12-5/8" 15-5/8" 17-5/8" 17-5/8" C (IPS thread) 1" 1-1/4" 2" 2-1/2" D (NPT thread) 3/4" 1" 1-1/2" 2" Pulses per Cubic Meter *These pulse rates available in MJNR dual reed switch meters only. tthis pulse rate available in MJNR single reed switch meters only. FLOW RATES (GPM) 3/4" 1" 1-1/2" 2" Minimum Maximum PRESSURE DROP CURVE " /2" " Rate of flow in gallons per minute (GPM) 53 Provided / Distributed / Serviced By: Phone: (800) (513)

67 Seametncs ORDERING INFORMATION MODEL SIZE PULSE RATE OPTIONS Reed switch = MJNR Hall-effect sensor = MJNE Totalizer only = MJNT 3/4" = " = /2" " = -200 T*20 Pulse/Gal = 20P tl 0 Pulse/Gal = 1013 *4 Pulse/Galma 4P *2 Pulse/Gal = 2P 1 Gal/Pulse us 1G *5 Gal/Pulse = 5G 10 Gal/Pulse = 10G *50 Gal/Pulse = 50G 100 Gal/Pulse = 100G 1 CF/Pulse = 1CF CF/P = 5CF 10 CF/P = 10CF 1 P/CM = 1CM 10 P/CM = 10CM 100 P/CM = 100CM [MI pump connector = -06 Seametrics control connector = -07 t3/4" Only *MJNR Meters Only ACCESSORIES Pulse divider = PD10 Pulse splitter = PS40 Pulse timer = PT35 Provided / Distributed / Servl By: Phone: (800) (513)

68 imag-series Flanged Magmeter FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total 4-20mA output available Tamper-evident seal NSF-61 approved IP68 rated APPLICATIONS Water & wastewater Municipalities Treatment plants Pump stations Cooling towers Packaged plants Filtration systems M On leneoreee Programmable Indicator Certified to NSF/ANSI imag GENERAL INFORMATION The IMAG-Serles is the most economical flanged electromagnetic flowmeter on the market. It is used in 3" to 12" pipe in municipal or industrial water, wastewater, pump stations and packaged plant applications. The imag has no moving parts and electrodes are designed to discourage fouling. This magrneter requires no maintenance in applications where debris would impede mechanical meters. There are no parts to wear out. Minimal straight pipe requirements allow imag-series meters to be used in piping configurations where there is little space between the meter and an elbow. imag-series meters are rated IP68 for applications where the meter may be under water up to a depth of 10 feet (3 meters) for prolonged periods of time. Rate and total indication are standard. Rate and total units 55 and pulse output are settable via the front panel touch key pad by the user. Bi-directional flow is standard. Forward, reverse and net flow can be read from the display. If forward and reverse flow data needs to be sent to another device, either the -ADDX, -DDDX or Modbus output is required. The imag can be externally powered with 9-36 Vdc at 30 ma average. The standard 20-foot (6 meter) cable also provides outputs for use wlth a variety of Seametrics and other displays and controls for remote reading, data logging and telemetry applications. 4-20mA passive current loop and high frequency outputs are optional. The imag 3600 remote display meter can be supplied with an optional internal AC power supply. Provided / Distributed! Serviced By: Meters I Controls [Equipment I Service Phone: (800) (513)

69 Seametncs FEATURES Continued Rate and total indicator Security seal & cross-drilled screws (2) for tamper-evidence Power and Output cable port access, tamper-sealed Configuration Port 'For Factory Lrse Or4). Powder-coated ductile cast iron body & electronics housing Equalization lug Glass filled molded plastic liner 3165S electrodes (Inside) Flanges, 150 lb. ANSI pattern imag Rate and total indicator with protective cover and keypad sensors Powder-coated ductile cast iron electronics housing Security seal & cross-drilled screws (2) for tamper-evidence Power and Output cable port access 46 Configuration Port (For Factory Use Only) Flanges, 150 lb. ANSI pattern Equalization lug 316SS electrodes (Inside) Santoprene/Polypropylene Liner Welded steel epoxy-coated flow tube imag i M A G (Remote indicator) Provided / Distributed / Sertgl By: Meters I Controls [Equipment I Service Phone: (800) (513)

70 imag-series Flanged Magmeter SPECIFICATIONS* Pipe Sizes 3",4", 6",P, 10", 12" Flanges Pressure 150 lb. ANSI pattern 150 psi (10.3 bar) working pressure Temperature Operating 10' to 130 F (-12 ' to 54' C) Accuracy Low Flow Cutoff Storage -40' to 158 F(-40' to 70 C) +/- 1% of reading +/ % of full-scale flow from low flow cutoff to maximum flow rate of 10 m/sec 0.5% of maximum flow rate Materials Body (3" Only) Ductile cast iron, powder-coated w/nsf61 listed epoxy powder Body (4"-12") Liner (3" Only) Liner (4"-12") Electronics Housing Electrodes 0-ring (3" Only) Welded steel, epoxy-coated Noryle Santoprene/Polypropylene Ductile cast iron, powder-coated 316 stainless steel EPOM Display Type 128x64 dot-matrix LCD Digits 5 Digit Rate 8 Digit Total Units Please Note: AU IMAG mean are factory ear for gallons Por minuta (Oem) rate and &dons total. Nether Unit! are required. they can be angular:nod In tho field. BI-directionaR Rate Volume Units Rate Time Units Total Volume Units Gallons Liters Cubic Feet Cubic Meters Million Gallons Mega Liters Imperial Gallons Million Imperial Gallons Forward Total. Reverse Total, Net Total Second Minute Hour Day Power DC Power 9-36 VdcCO 250 ma max, 30 rna average Pulse Frequency Output AC Power' Vac, 50/60Hz, 0.12A Signal Pulse Rates Current sinking pulse, isolated, 36 Vdc at 10 ma max Gallons C u b i c Meters x 1000 Gallons x 1000 Cubic Feet Million Gallons Cubic Feet x 1000 Liters M i l l i o n Cubic Feet Kilo Liters I m p e r i a l Gallons mega Liters Imperial Gallons x 1000 Cubic Meters Million imperial Gallons User-scalable from 0.1 to 99,999.9 volume units/pulse. Pulse width is one-half of pulse period with minimum pulse width of 2.5ms, 200 pulses/sec max Options 4-20mA Current Loop Isolated, passive, 6-36Vdc, error less than +/- 0.1% of pulse/frequency output, HART compliant' Digital Output Serial Communications Isolated, open collector, 10mA max., frequency output at max, flow selectable as 0.5, 1.2,5 or 10kHz Isolated, asynchronous serial RS485 (Reconfigurable for RS232 or 3.3V CMOS), Modbus RTU protocol Cable Control Cable Six-conductor water-blocked cable, polyurethane jacket, 20ft (6m) standard length for power, pulse frequency or optional outputs. Optional lengths up to 100' available Conductivity Empty Pipe Detection Regulatory Environmental Remote Display Cable (imao 3600) 33ft (10m) standard length may be shortened by user in the field). Additional cable can be ordered and attached with the use of a junction box (purchased from a standard supplier) up to 100ft (30m) total >20 microsiemens/cm Hardware/software, conductivity-based CE (EN 61326) pending, NSF-61. 1P68 to 10ft (3m) depth *Specifications subject to change. Please consult our website for the most current data ( If forward and reverse flow data needs to be sent to another device, either the -ADDX, -000X or Modbus output Is required. -'1M1,101G3600 only, IMAG4600 requires external AC power supply 57 Provided / Distributed / Serviced By: Phone: (800) (513)

71 Seametrics DIMENSIONS imag Shown (Including Gaskets) IMAG3600 Remote Shown D I IMAG to 1200 Shown 1 T C 6 W (Metal Flange) Evil f f 4 weir (Including Gaskets) Provided / Distributed / Sento] By: Phone: (800) (513)

72 imag-series Flanged Magmeter imag Dimensions Acuracy(%) imag Meter Size L H T ID Shipping Weight inch mm inch mm Inch mm inch mm pounds Kg 3" " ,, ,, " " Flanges Standard ANSI 150 lb. drilling pattern Cable 1 lb FLOW RANGE (3" - 12") Pipe Size (Inches in diameter) 3" 4" 6" Er, 10" 12" Max Flow Velocity (Meters/Second) Max Flow Rate (Gallons/Minute) Max Flow Rate (Liters/Second) Turn Down Flow Rate (Gallons/Minute) Turn Down Flow Rate (Liters/Second) imag Accuracy (m/s) (ft/s) Flow Velocity 59 Provided / Distributed / Serviced By: Phone: (800) (513)

73 Seametrics ORDERING INFORMATION IMAG 3600 (Remote Indicator) Options O SIZO 0 Flange/Fitting 0 IMAG 3600 Power and Communications 0 Power/Output Cable Sensor Cable " -F1 ANSI 150# -ADDX A C Power. 2 Digital Outputs -000 N o Cable meter ( ' ' ' ' " -ADLX A C Power, Current Loop. Digital Output -APLX A C Power. Pulse, Current Loop -APXX A C Power, 1 Pulse Output -ASSX A C Power, Modbus meter (20) meter (66') meter (33') meter (100') meter (66') meter (100') " -DDDX D C Power, 2 Digital Outputs -DDLX D C Power, Current Loop, Digital Output -DPLX D C Power, Pulse, Current Loop -DPXX D C Power, 1 Pulse Output -DSSX D C Power, Modbus IMAG 4600 (internal Indicator) Options siz. 0 Flange/Fitting 11) IMAG 3600 Power and Communications 0 Power/Output Cable " -F1 ANSI 150# -DDDX D C Power, 2 Digital Outputs -000 N o Cable " -DDLX D C Power, Current Loop. Digital Output meter (20') '' -DPLX D C Power, Pulse. Current Loop meter (33') " -DPXX D C Power, 1 Pulse Output meter (66') " -DSSX D C Power, Modbus meter (100') " '6 meter (20') porta cable (IMAG 3600 or IMAG 4000) and 9 meter (30') sensor cable WAG 3600 only) are included at no additional charge, 'All IMAG meters are factory set for gallons per mil ute (GPM! rate and gallons total. 0 other units are required, they can be programmed In the field. Provided / Distributed / Serviffp By: Meters I Controls [Equipment I Service Phone: (800) (513)

74 WJ-SERIES Pulse Meter FEATURES Non-resettable mechanical totalizer 2, 3, 4, 6, 8" pipe sizes Optional pulse output Rugged construction Accurate and economical APPLICATIONS Remote totalizing Pacing electronic metering pumps Cooling water monitoring Industrial fluid control Water/Wastewater treatment GENERAL INFORMATION WJ-Se ries turbine meters are dry-register mechanical totalizers that offer accurate, economical reading of high flows with low pressure loss. The horizontal-axis turbine drives a vertical shaft, which is magnetically coupled to the sealed register. In addition to mechanical totalizing, registers can be equipped with magnetic pulse reed sensors well suited for remote totalizing, pacing of electronic metering pumps, and water treatment applications. 61 Bodies are manufactured of tough cast iron and epoxy-coated for protection. Tungsten steel shafts and jewel bearings further enhance the durability of these meters. Simple removal of the top flange brings out all parts for inspection, repair, or replacement. The meter has a tamper-evident seal to call attention to unauthorized access. Compatible Seametrics controls include the P135 pulse timer, the PD10 pulse divider, and the PS40 pulse splitter for running multiple pulse-responsive devices (e.g. pumps, counter timers and remote totalizers) with a single WJ meter. Provided / Distributed / Serviced By: Phone: (800) (513)

75 Seametrics Register seal Lid Security bolt & seal Display Security Seals 150 lb. ANSI drilling flange Epoxy-coated cast iron body 3" Meter Gaskets included SPECIFICATIONS* Materials Meter Body Register Plate Drive Magnet Turbine Turbine Shafts Bearings Flanges Maximum Pressure Cast Iron, epoxy coating ABS plastic Alnico Plastic Tungsten steel Jewel 150 lb. ANSI drilling 200 psi (14 bar) Maximum Temperature 105 ' F (40 C) Accuracy* Above Transition Below Transition Reed Switch +/-2% of reading +/-5% of reading no ma 0 24 Vac/dc *Specifications subject to change. Please consult our webstte for current data (wwwseametrics.com). Provided / Distributed / Servis21 By: Phone: (800) (513)

76 WJ-SERIES Pulse Meter DIMENSIONS H 1. HIJ H2 2", 3", 4" Dimensions 2" 3" 4" L 7.87" 8.86" 9.84" H 10.08' 10.87" 11.26" Hi " 13.70" 14.09" H ' 15.75" Wt lbs lbs lbs. Hi - Lid clearance for reading display H2 = Head clearance for replacing turbine insert 1 `I 4 L 1,. 2", 311, 4" I LI CI I 11 1_1 I I ( H H1 H2 6", 8" Dimensions 6" 8.. L 11.81" 13.78" H 13.60" 14.67" H " 17.50' H " 19.69" Wt lbs. 141 lbs. H1 --- Lid clearance for reading display H2... Head clearance for replacing turbine insert -.1 L 6", 8" 63 Provided / Distributed / Serviced By: Phone: (800) (513)

77 Seametrics FLOW RANGE (GPM) 2" 3" 4" 6" 8" Minimum Max. Continuous Transition* *The flow rate at which accuracy changes from +/-2% of reading (above Transition) to +/-5% of reading (below Transition). 3 4" 6" 5. 2 PRESSURE LOSS PSI BO FLOW RATE GPM ORDERING INFORMATION MODEL SIZE OPTIONS PULSE RATE (Select with Option -17 Only) WJ 2" = -200 Pulse Output/Reed Switch = -17 Meter Size Pulse Rate 3" = -300 (Select pulse rate at right) 10 Gal/Pulse = 10 G 4" = " 100 Gal/Pulse = 100 G 6" = " 1000 Gal/Pulse - 1,000 G 8" = " 10,000 Gal/Pulse = 1.0,000 G 1NJ ACCESSORIES Pulse Timer = PT35 Pulse Divider = PD10 Pulse Splitter = PS40 Provided / Distributed / Serv10 By: Phone: (800) (513)

78 WMP-SERIES Plastic Bodied Magmeter APPLICATIONS Usage monitoring, such as: Industrial wastewater discharge Grey water Well monitoring Irrigation FEATURES No moving parts Minimal straight pipe required Battery powered Built-in rate & total indicator Corrosion resistant Pulse output (WMP101 only) 3 Inch Unobstructed Flow 2 Inch 1 Inch GENERAL INFORMATION The WM P-Series is a full-bore, plastic-bodied electromagnetic flow meter designed for flow and usage monitoring applications in 1, 2 and 3 inch pipe. The polypropylene flow tube offers corrosion resistance to a wide range of chemicals and fertilizers. It is light weight and easy to install or remove from the pipe for inspection*. With no moving parts, the magmeter permits unobstructed flow, minimizing flow disturbances and straight pipe requirements. The WMP-Series can be used in piping configurations where there is little space between the meter and an elbow or valve. The WMP-Series is resistant to wear from sand and debris found in ground or surface water. Since there are no bearings or propeller to wear out, maintenance and repair costs are kept to a minimum and it tolerates high flows without damage. A hinged polyethylene cover is included that protects from dust and UV rays, while permitting easy access to the flow rate and total display. The electronics housing can be fitted with crossdrilled screws and seal wire for tamper-evidence. Flow rate and total can be displayed in a variety of units, customer-selected and factory-set. The WMP-Series is used for tracking flow rate and total flow in usage monitoring applications including wells, industrial wastewater, heap leach mining discharge, coolingtower deduct, turf, landscape, and other water reclamation applications. In the event of DC power loss, or when changing batteries, the WMP will retain internal settings and flow total. The WMP101 is externally powered via a 5-pin connector cable (20f/6m) which also provides pulse output for use with a variety of Seametrics and other displays and controls for remote reading, data logging, pulse-to-analog conversion, and telemetry applications. The WMP104 is a battery-operated unit for use when pulse output is not required. The standard batteries are user replaceable with an approximate 1-2 year life depending on usage. An extended battery life option offers an estimated 2-4 year life depending on usage. *Includes Seametrics NPT fitting kit on 2" and 3" models. 65 Provided / Distributed / Serviced By: Phone: (800) (513)

79 Seametrics Polyethylene protective cover LCD rate and total indicator Powder-coated diecast-aiuminum electronics housing Cross-drilled screws (2) for tamper-evidence Seametrics Fitting Kit for 2 & 3 Inch models 316SS electrodes Corrosion-resistant glass-filled polypropylene body Lightweight for easy handling SPECIFICATIONS* Pipe Size 1, 2 or 3 inch full port Fittings 1 inch NPTF, 2 or 3 Inch flange clamps with 2 or 3 Inch NPTF or I3SP fitting kit Pressure 150 psi or 10.3 bar working pressure 0 70 F Operating Temperature Range 10' to 130. F (-12 to 54' C) operating, -40' to 176' F (-40' to 80' C) non-operating Accuracy +/-1.% of reading (between 10% and 100% of max flow) +/-3% of reading (between cutoff and 10% of max flow) Flow Range Minimum 1 inch: 2.3 GPM (.145 LPS) 2 inch: 6 GPM (.38 LPS) 3 inch: 14 GPM (.88 LPS) Maximum 1 inch: 110 GPM (6.94 LPS) 2 inch: 300 GPM (18.9 LPS) 3 inch: 670 GPM (42.3 LPS) Materials Body Glass-filled polypropylene Electrodes 316 stainless steel Electronics Housing Diecast aluminum, powder-coated Display Security Display Cover Digits Units Power WMP101 WMP104 Pulse Output Signal (wan'101 than Pulse Rate amp= ostr) Low Frequency (-PxU) Empty Plpe Detection Conductivity High Frequency (-w) Pulse/Gal Puise/Llter Polyethylene Rate Total 6 8 GalionVMinute, Million GalionWDay, Cubic Feet/Second, Acre-Feet, Acre-Inch, Gallons, Gallons x 1000, Cubic Feet/Minute, Liters/Second, Liters/Minute, Cubic Feet, Liters, Megaliters, Cubic Meters, Million Liters/Day, Cubic Meters/Minute, Cubic Meters/Hour Cubic Meters x1000 Cross-drilled screws and tamper-evident seal (optional) ma max (15 ma average) NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation 6 each AA alkaline cells, replaceable. Estimated life is 1 year depending on usage (standard) 2 each C lithium batteries, replaceable. Estimated life is 2-4 years depending on usage (Extended battery life option) Current sinking pulse, opto isolated, 32 Vdc may at 10 ma max 1 unit/pulse out, pulse width of 10ms depending on unit selection 1" 2" 3" Pulse width 1.1 ms, min - max frequency, hz / Hardware/software, conductivity-based >20 microsiemens/cm Environmental NEMA 4X standard Electrical Connection (WMP1010nly) 5 pin male circular connector, mates to industry standard cable *Specffications subject to change Please consult our website for current data ( Provided / Distributed / Servisol By: Phone: (800) I +1 (513)

80 WMP-SERIES Plastic Bodied Magmeter DIMENSIONS 1 Inch Power/Output Cable S e a m e t r I c s WMP Fitting Kit WM P101Only (Not Shown) 2 inch 3 inch STRAIGHT PIPE RECOMMENDATIONS 2X -ix Minimal straight pipe required between elbows. For other piping configurations, consult factory. FLOW RANGE 1" 2" 3" Gal/Min Liter/Sec Gal/Min Liter/Sec Gal/Min Liter/Sec Minimum Maximum Provided / Distributed / Serviced By: Phone: (800) (513)

81 ORDERING INFORMATION Seametncs MODEL S I Z E OPTIONS UNITS External Power = WMP101 1 " = -100 Tamper-evident seal. RATE ORDER TOTAL ORDER screws, and wire = -32 Gal/Min = GPM Gal = G Battery Power = WMP104 = -200 Liters/Sec LPS Gal x 1000 = GT Extended Battery Life = -133 Liter/Min = LPM Cubic Feet = CF MP 1O4 Only) 3" = -300 Cu Ft/Sec = CFS Acre Inch = Al Cu Ft/Mm = CFM Acre Feet = AF *High frequency output = -HF Cu Met/Min = CMM Liter = L (WMP101 Only) Cu MeVHr = CMH Mega Liters = ML Mil Gal/Day = MGD Cubic Meters = CM BSP fittings = -93 Mil Lit/Day = MID Cu Met x 1000 = CMT *See specifications for default. Consult factory for additional units. ACCESSORIES Remote 4-20 ma (analog) signal = A055W (-HF Option Required, VVMP101 Only) Remote Rate and Total Indicator = FT400 Senes (-HF Option Required, WMP101 Only) Remote Data Logger= DL76W (WMP101 Only) 2" Fitting Kit, FNPT Flange Clamps = " Fitting Kit, BSP Flange Clamps = " Fitting Kit, FNPT Flange Clamps = " Fitting Kit, BSP Flange Clamps = Provided / Distributed / Serviml By: Meters I Controls [Equipment I Service Phone: (800) (513)

82 WMX-SERIES Flanged Magmeter APPLICATIONS Filtration systems Pump stations Municipal water/wastewater Industrial water/wastewater Cooling tower water treatment Packaged plants FEATURES No moving parts Built-in pulse output for data logging or telemetry Minimal straight pipe required Continuous battery or external power IP68 submersible (option) WMX104 WMX WMX GENERAL INFORMATION The WMX-Serles are flanged electromagnetic flowmeters for use in 3" to 12" pipe in municipal or industrial water and wastewater applications where propeller meters have typically been used in the past. Because the WMX has no moving parts and has electrodes designed to discourage fouling, this magmeter performs well and requires much less frequent maintenance in applications where debris would impede propeller meters. There is no rotor to stop turning or bearings to wear out. Minimal straight pipe requirements allow WMX-Series meters to be used in piping configurations where there is little space between the meter and an elbow. In chemical injection applications, the chemical injection point must be placed downstream of the magmeter OR far enough upstream for complete mixing to occur before the fluid reaches the meter. The submersible units, -168 option, are rated IP68 (NEMA 6P) for applications where the meter may be under water up to a depth of 3 meters for prolonged periods of time. Rate and total indication are standard on both models. Units are customer-selected and factory-set. No set-up is required. The WMX1.01 is externally powered with 8-32 Vdc at 30 ma max (see NOTE in Specifications). Two Lithium 3.6V "M" batteries provide auxiliary power during power failures, allowing the meter to continue recording flow rate and total without interruption for the duration of the outage. Where external power loss is infrequent, battery life exceeds 10 years. The 20-foot power cable also provides pulse output for use with a variety of Seametrics and other displays and controls for remote reading, data logging, pulse-to-analog conversion, and telemetry applications. High frequency pulse rate (required for use with 4-20 ma converters) is standard; additional pulse rates are optional. The WMX104 is a battery-operated unit for use when pulse output is not required. Two Lithium 3.6V "D" batteries provide power and are replaceable with an approximate 1-year life under continuous use, or more depending on the duty cycle. An optional input/output cable can be installed post-factory if needed for changing applications. FLOW RANGE (3" - 12") Meter Size 3,, 4" 6" 8" 1.0" 12" GaVMin Liter/Sec GaVMin Liter/Sec GaVMin Liter/Sec Gal/Min L i t e r/s e c Gal/Min Liter/Sec Gal/Min Liter/Sec Minimum Maximum , , , , , Provided / Distributed / Serviced By: Phone: (800) (513)

83 Seametrics Rate and total indicator Powder-coated diecast-aluminum electronics housing Tamper-evident security seal & cross-drilled screws (2) for tamper-evidence Internal Data Logger (Optional) Power/Output cable port access, tamper-sealed (NOTE: WMX101 comes with standard 20' cable installed) Equalization lug Welded steel epoxy-coated flow tube 316SS electrodes Dual durometer rubber liner Flanges, ANSI 150 lb. drilling WMX104 Rate and total indicator Tamper-evident security seal & cross-drilled screws (2) for tamper-evidence Power/Output cable port access, tamper-sealed (NOTE: WMX101 comes with standard 20' cable installed) Internal Data Logger (Optional) Powder-coated ductile cast iron electronics housing IP68 Housing Option (For 4"-10" meter & 12" battery only; standard for 3" model) Rate and total indicator Tamper-evident security seal & cross-drilled screws (2) for tamper-evidence Power/Output cable port access, tamper-sealed (NOTE: WMX101 comes with standard 20' cable installed) Internal Data Logger (Optional) Powder-coated ductile cast iron body & electronics housing Glass filled molded plastic liner 316SS electrodes Flanges, ANSI 150 lb. drilling WMX Equalization lug (IP68 istandard for 3" model) Provided / Distributed / Servifed By: ATG Phone: (800) (513)

84 WMX-SERIES Flanged Magmeter SPECIFICATIONS* Pipe Sizes 3",4", 6, 8", 10", 12" Fittings Pressure ANSI 150 lb. drilling 150 psi (10.3 bar) working pressure Temperature Operating 10' to 130' F (-12' to 54' C) Accuracy Materials Body (3" Only) Display Power Non-Operating -40 to 158' F(-40' to TO' C) Body (4"4.2") Liner (3" Only) Liner (4"-12") +1-1% of reading for flow between /0% to 100% of max flow +/- 2% of reading for flow from cutoff to 10% of max flow Ductile cast iron, powder coated w/nsf61 listed epoxy powder Welded steel, epoxy-coated Norylig) Santoprene/Polypropylene Electronics Housing Diecast aluminum, powder-coated (non-1p68) Ductile Cast Iron (IP68) Electrodes 0-ring (3" Only) Digits Units Pulse Output signal Conductivity Empty Pipe Detection Environmental Pulse Rates High Frequency (pulse/gal) 316 stainless steel EPDM Rate 5 8 Gallon/Minute, Liter/Minute, Liter/Second, Cubic Feet/Minute, Cubic Meter/Hour, Million Gallon/Day, Mega Liter/Day Total Gallon, Gallon x 1000, Liter, Liter x 1000, Mega Lit( Cubic Meters, Cubic Meter x 1000, Cubic Feet, Cubic Feet x 1000 WPAX101: 8-32 Vdc at 30 ma max, with auxiliary battery for continuous operation during power failures NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line Input voltage fluctuatic WMX104: 2 Lithium 3.6V "D" batteries, replaceable, 1 year life under continuous use. wmxiot Current sinking pulse, opto-isolated. 30 Vdc at 10 ma max WMX104: Pulse output available only with addition of post-factory output cable High Frequency; 10 units/pulse; 100 units/pulse; 1000 units/pulse 3,. 4" 6" 8., 3.0" 12" >20 microslemens/cm Hardware/software, conductivity-based NEMA 4X Standard (IP68/NEMA 6P Option) 'Spec/kat/cos subject to change. Please consult our website for the most current data ( DIMENSIONS r, Metal Flange) (Including Rubber Gaskets)!Including Rubbei Gaske15) WMX Shown (3") WMX Shown (4"-12") (1P68 Housing) WMX104 Shown (4"-12") 71 Provided! Distributed / Serviced By: Phone: (800) (513)

85 WMX / (IP68 Housing) IP68 WMX Meter Size L H T ID Shipping Weight P68 Version inch m m inch mm inch mm Inch mm pounds Kg 3" " " " " tir Flanges Standard ANSI 150 lb. dril ing C a b l e (WMX 101) 1 lb. tip68 available for WM X only. IPB8 is not available for WMX WMX101/104 (Standard Housing) Standard WMX Meter Size L H T ID Shipping Weight Standard inch mm inch mm inch mm inch mm pounds Kg 4" " ,, " " Flanges Standard ANSI 150 lb. dril ing C e d e (wmx tani lb. ORDERING INFORMATION Seametncs MODEL SIZE OPTIONS FLOW MEASUREMENT UNITS External power = WMX101 3" = -300* High Frequency = -HF RATE O R DER TOTAL O R D E R Battery power = WMX104 4" = Units/Pulse = -PxX Gal/Min = GPM Gal = G Liter/Min = LPM Gal x 1000 = GT 6" = Units-/Pulse = -PxH Liters/Sec = LPS Liter = L 8" = Units""/Pulse = -PxK Liter x 1000 = LT Cu Ft/Min = CFM Mega Liters M L 10" = Factory Installed Power Cable Cu Meter/Hr = CM H Cubic Meters = CM 12" = m (20 ft) = -11/6 Mil Gal/Day = MGD Cu Met x 1000 = CMT Meg Lit/Day = MLD Cubic Feet C F Factory Installed Power Cable Cu Feet x 1000 OFT 15m (50 ft) = -11/16 Internal Data Logger = -127 IP68 Submersible = -168t IP68 available for wry1x only ' Is IP68 only IPSO is not available for WMX "'Units Gal or Liter depending on Rate/Total unit selection Consult factory for additional units Any rats selection can be combined with any total selection ACCESSORIES Remote 4-20 ma (analog) signal = A055W Remote Rate and Total Indicator (Battery) = FT450 Remote Rate and Total Indicator (Powered) = FT400 Series Remote Data Logger = DL76W Dual Power Supply, 115 Vac, 12/24 Vdc = PC42 (Use with High Frequency pulse rate) Replacement Battery Pack for VVMX101 = Replacement Battery Pack for VV1VIX104 = Post-Factory Power/Output Cable (WMX104 Standard Housing Only) = DC30 Post-Factory 50-ft Power/Output Cable (WMX104 Standard Housing Only) = DC35 Post-Factory 100-ft. Power/Output Cable (WMX104 Standard Housing Only) = DC100 Post-Factory 20-ft. Power/Output Cable (1NMX104 IP68 Housing Only) = DC3OS Post-Factory Power/Output Cable (WMX104 IP68 Housing Only) = DC355 Post-Factory 100,A PowiartOutput Cable (WMX104 IP68 Housing Only) = DC100S Grounding Rings (not needed for most applications): 3'" " = " = " = " = " = Provided / Distributed / Servini By: Phone: (800) (513)

86 WT-SERIES Turbine Meter FEATURES One moving part Low friction jewel bearings Field repairable without removal from the line Choice of materials for chemical compatibility Variety of displays and controls APPLICATIONS Water treatment Wastewater treatment Cooling water monitoring Industrial fluid control WTC GENERAL INFORMATION This unique system of 2" to 8" turbine meters uses just one moving part, a precision helical rotor. Rotation of the rotor is electronically detected and processed. The high-quality jewel bearings and shafts minimize friction while providing long wear life in non-lubricating fluids. The entire rotor assembly can be easily removed for field service without removing the meter from the pipe. WTP bodies are fabricated from Schedule 80 PVC fittings, WTC bodies from carbon steel tubing, and WTS bodies from stainless steel tubing. The turbine insert on WTC and WTS meters is machined from a stainless steel casting. The WTP turbine insert is machined from a solid piece of PVC. Turbine rotors on all models are Kynar (PVDF). WT meters can be ordered with various output options. The basic model (100) comes with pulse output only. An electronic display (Seametrics FT400 series indicator) is mounted on the 101 model to display flow rate and total (resettable or non-resettable), and provide a programmable pulse or 4-20 ma output. Other electronics options include a blind 4-20 ma transmitter (A055) on the 102 model and a battery-powered (F1450) rate/totalizer plus pulse output for applications that lack power (104 model). All of these controls/displays can be mounted on the meter or remotely mounted on a wall or panel up to 2,000 feet away. WT- Series meters are compatible for use with most other remote-mount Seametrics displays and controls as well. 73 Provided / Distributed / Serviced By: Phone: (800) (513)

87 FEATURES Modular electronics for a wide range of applications (available as meter or remote mount) Pulse output only (100 model) - Rate/total and 4-20mA output (101 model) Analog 4-20 ma transmitter (102 model) - Battery-powered rate/totallzer and programmable pulse output (104 model) Rugged cast control housing Rotor is the only moving part 150 lb. drilling flanges or female NPT threaded (depends on model and size) T'N`c Lz- Seametncs Cast stainless steel (WTC & WTS) or PVC (WTP) Insert removes easily for service Jewel bearings for long life and low friction resulting In lower minimum flows Schedule 80 PVC (WTP); Fabricated carbon steel (WTC); or stainless steel (WTS) SPECIFICATIONS* Pipe Sizes 2", 3", 4", 6" 2", 3", 4", 6,8' 2,3", 4", 6", 8" materials Meter Body PVC Schedule 80 fittings Painted carbon steel 304 Stainless steel (316 SS optional) Turbine Insert PVC CF8M cast stainless CF8M cast stainless Rotor Kynar (PVDF) Kynar (PVDF) Kynar (PVDF) Shaft Zirconla ceramic 3%6" Zirconia ceramic 3"-8" Zirconia ceramic 3"-8" Shaft Tungsten Carbide 2" Tungsten Carbide 2" Tungsten Carbide 2" Bearings Sapphire Journal, ruby endstone Sapphire Journal, ruby endstone Sapphire Journal, ruby endstone Cable #22 AWG, 2000' max #22 AWG, 2000' max #22 AWG, 2000' max Flanges Optional (See Dimensions) 150 lb. drilling (3-8" only) 150 lb. drilling (3-8" only) Maximum Pressure 150 psi at 75 F (10 bar 24" C) (see chart) 200 psi (14 bar) 200 psi (14 bar) Maximum Temperature 120' F(50' C) (see chart) 200' F(93' C) 200' F(93" C) Accuracy 3"-8" +/- 1% of full scale +/- 1% of full scale +/- 1% of full scale 2" +/-2.5% of full scale 4-/- 2.5% of full scale +/-2 5% of full scale Flow Range (GPM) 2" 3" 4" 6" 2" 3" 4" 6" 8" 2" 3" 4" 6" 8" Electronic Options Specifications* WTP Minimum Maximum WT100 (Pulse Output Only) WT102 (Blind 4-20 Transmitter) (e.g. A055) Power 6-24 Vdc Power Vdc (isolated) Pulse Output pulse/second current sinking Analog Output 4-20 ma loop WT103/WT105 (Powered Rate/Totalizer) (e.g. FT400 Series) Response Time 2-60 seconds, 90% of full scale Power Vdc (for 4 ma DC min); (depends on input averaging) Vdc (for accuracy of 4-20 ma loop) WT107 (Battery-powered Rate/Totalizer) (e.g. F1450) Rate 6-digit autorange Power 3.6 Vdc Lithium battery Total 8-digtt replaceable, 3-5 year life Memory Non-volatile (no battery needed) Rate 6-digit auto range Pulse Output 0.1 second open collector (scaled); 0-75 pulse/second passthrough Total 8-digit (unsealed); High alarm or low alarm Pulse Output 0.1 second open collector (scaled); Analog Output 4-20 ma loop (24-32 Vdc required) 0-75 pulse/second passthrough (unscaled); 1-ugh alarm or low alarm *Specifications subject to change Please consult our website for current data ( WTC WTS Provided! Distributed / Semi?* By: Phone: (800) (513)

88 WT-SERIES Turbine Meter DIMENSIONS WTP METER Optional Flanges - A Meter Size Dim A Dim B 2" 10" 7.5" 3" 12" 6.5" 4" 14" 7.0" 6" 18" 8.5" Note: Flange option face-to-face dimension ("A") is the same as plain ends. WTC and WTS METERS A.1 Female NPT threaded ends standard. Flange ends available A 3"- 8" Meter Flange 150 lb drilling Meter Size Dim A 2" * 8"/$10" 3" 12" 4" 14" 6" 18" 8" 20" *Without flange twith flange PRESSURE and TEMPERATURE PRESSURE LOSS CHART (ALL) PRESSURE VS. TEMPERATURE (WTP Only) 3 P.S.L 2 2" 3" y, PS.' GPM 2000 w-c & VUTS Only ' ' ' 130' F' Provided / Distributed / Serviced By: Phone: (800) (513)

89 Seametrics TYPICAL APPLICATION F1420W Flow Compu er Metering Pump Treatment Chemical Oa 0 C mA Device GPM 420 ma Loop (also powers F1420) Static Mixer FLOW 0- WTP METER ORDERING INFORMATION MODEL ELECTRONICS SIZE OPTIONS Carbon Steel = WTC Pulse Output = 100 2" = -200 Micropower Sensor = -04 PVC = WTP Rate+Total/Pulse/4-20 ma = 101 3" = -300 (For use with FT450W) Stainless Steel = WTS 4-20 ma only = 102 4" = SS (WTS only) = -14 Battery-Powered 6" = -600 Flanged Ends (WTP) = -18 Rate+Total/Pulse = 104 8" = -800 (VVTC & WTS Only) Flanged Ends (2" WTS) = -20 Flanged Ends (2" VVTC) = -34 Carbide Shaft (3"-8") = -119 ACCESSORIES Remote Rate and Total Indicator = FT440W Remote Blind 4-20 ma Converter = A055W Remote Battery-Operated Rate/Totalizer = FT450W Remote Pulse Divider = PD1OW Provided / Distributed / Serviml By: Phone: (800) (513)

90 PE202 Low Flow Magmeter APPLICATIONS Chemical injection Corrosive materials Low flow applications Pulsating flows (e.g., metering pump) FEATURES No moving parts Requires no straight pipe Pulse and/or 4-20 ma output Chemical and corrosion resistant Insensitive to fluid density and fluid viscosity changes GENERAL INFORMATION The PE202 magmeter is designed for low-flow chemical injection or difficult-to-meter applications with pulsating metering pumps in 3/4" to 1/4" pipe/tube. The housing is made of sturdy splashproof HDPE plastic. With no moving parts, the PE202 can handle fluids containing particulate matter without clogging or jamming, keeping maintenance at a minimum. With no metallic parts (100% PVDF body and PVDF carbon fiber-filled electrodes), the meter is corrosion-resistant and compatible with a wide range of chemicals. Accuracy is maintained with conductive fluids (>20 microsiemens) of varying viscosities and densities. The PE meter is compact enough to fit most pump/injection systems. With zero straight pipe required after an elbow, it can be easily mounted in tight spaces. The mounting bracket adds stability. The PE meter has an optoisolated current sinking pulse output that can be connected to the Seametrics FT420 rate/total display or FT520 batch processor, as well as an optoisolated 4-20 ma current loop for powering analog devices. Outputs and power are provided through a 20 foot (6 meter) cable with 8-pin female circular connector. 77 Provided / Distributed / Serviced By: Meters I Controls [Equipment I Service Phone: (800) (513)

91 Seametncs FEATURES 8-pin circular bulkhead connector, 20 foot (6 meter) cable provided Internals made of chemical and corrosion-resistant PVDF Sturdy HDPE housing 1/2" male NPT fittings standard Mounting bracket Threaded male or female NPT adapters can be purchased separately (available in PVDF and PP) SPECIFICATIONS* Pipe Size 3/4", 1/2", 3/8", 1/4"** Fittings 1/2" NPT fittings standard in 3/4" or 3/8" flowbody. NM-threaded adapters available for above pipe sizes. Materials Body PVDF Electrodes Ground Housing Adapters (NPT) PVDF carbon fiber filled PVDF carbon fiber filled HDPE with 2595 glass Polypropylene or PVDF Temperature Ambient 0" to 130' F (-18" to 54" C) Fluid 32- to 200- F (0- to 93- C) Pressure 150 psi Flow Range GPM Max. (0.2 GPM cut off) GPM Max. (0.03 GPM cut off) Accuracy /- 1% plus +/ GPM of reading across rated range output Signal Power /- 1% plus +/ GPM of reading across rated range Optoisolated current sinking or current sourcing pulse output: 30 Vdc, 5 ma max Optolsolated 4-20 ma current loop: 7 Vdc plus load voltage drop min; 50 Vdc max -075 PE : 500 pulses/liter (1892 pulses/gallon), -038 PE : 1,000 pulses/liter (3785 pulses/gallon) Vdc, 150 ma (linear power supply recommended) Conductivity Empty Pipe Detection Environmental >20 microsiemens Hardware/software, conductivity-based NEMA 4X standard; IP 66 Splashproof standard *Specifications subject to change Please consult our website for current data (wwwseametn'cs.com). **Requires adaptors NOTE: Consult factory for applications towing sodium hypochlorlte, sodium chlorite, sodium chlorate. For applications with the listed chemicals, the following conditions apply: Max. Concentration 15% / Max Temperature 100' Flow is greater than 20% of max.for accurate reading Provided / Distributed! Serving By: Meters I Controls [Equipment I Service Phone: (800) I +1 (513)

92 PE202 Low Flow Magmeter DIMENSIONS 72 (Wahl ADAPTUZS AS SHOWN) I ME7EI2 WR1IOU1 ADAPTERS) 3.5 Mounting --Ir. Bracket 1 7,7 (WITH ADAPTERS AS SHOWN) 4.2" (METER WITHOUT ADAPTERS) 1[1111 IIMI PRESSURE DROP CURVE g DV7 Rate (gpm) PE with 3/4" adapters. PE with 3/8" adapters. Actual curve dependant on pipe size/fittings Provided! Distributed / Serviced By: Phone: (800) (513)

93 Seametncs ORDERING INFORMATION MODEL PE202 SIZE 31 = /8" = -038 FITTINGS Meter corri standard with 1/2-14 MNPT Fittings PE202 ACCESSOR I ES Rate and Total Indicator = FT400 Series Batch Flow Processor = FT520 Single 12Vdc Regulated Power Supply = PC12 Dual 12-24Vdc Regulated Power Supply = PC42 Adapter 0 otione: PE202 PVDF Adapter Kit 1/2" FNPT PE202 PVDF Adapter Kit 1/4" MNPT PE2D2 PP Adapter Kit 1/4" MNPT PE202 PVDF Adapter Kit 3/8" MNPT PE202 PP Adapter Kit 3/8" MNPT PE202 PVDF Adapter Kit 1/2" MNPT PE202 PP Adapter Kit 1/2' MNPT PE202 PVDF Adapter Kit 3/4" MNPT PE202 PP Adapter Kit 3/4" MNPT Provided / Distributed / Servisul By: Meters I Controls [Equipment I Service Phone: (800) (513) sales@aguatechnologygroup.com

94 SEB Low Flow Meter FEATURES Single-jet meter Compact brass body Union couplings Easy installation and maintenance Interfaces with many controls and displays APPLICATIONS Industrial control operations Low flow situations Clean water GENERAL INFORMATION S P E C I F I C A T I O N S * The SEB is a plated brass low flow meter suited for clean water. It is available in 1/2" and 3/4" thread, with uniontype meter couplings for easy installation and service. This meter is ideal for flow rates between 0.2 and 18 GPM. The SEB has only one moving part, the propeller. A 5-30 Vdc square wave output makes the SEB ideal for many industrial control applications. This signal interfaces easily with programmable logic controllers and computer input boards. SEB meters can also be used in conjunction with the Seametrics FT400 series flow computer for reading flow rate and total flow, or A055 for 4-20 ma output. For metering pump pacing applications, a standard PD10 pulse divider is recommended. Si. Sensor Fittings Materials Body Rotor Chamber Rotor Shaft Bearings GMR 5-30 Vdc current sinking pulse 1/2", 3/4" male NPT union couplings Nickel-plated brass Brass Thermoplastic Tungsten carbide Water-cooled thermoplastic Maximum Temperature 185 F(85 C) Maximum Pressure 175 psi (12 bar) Cable #22 AWG 3-cond, 12' Maximum run 2,000' (610 m) Flow Range Standard K-Factor Accuracy Regulatory a Mark 1/2": gallons per minute 3/4": gallons per minute 1/2": 550 pulses per gallon 3/4": 330 pulses per gallon +/- 1% of full scale *Specifications subject to change. Please consult our webs ite for the most current data ( Provided / Distributed / Serviced By: Phone: (800) (513)

95 Seametrics 1-iall-effect 12 Vdc signal interfaces with a variety of electronics Removeable top contains electronics, isolated from fluid Union ends with couplings Easy installation and service Compact nickel-plated body INSTALLATION and MAINTENANCE Installation. Single-jet meters like the SEB are somewhat Maintenance. The SEB's Hall-effect sensor and cap are insensitive to upstream and downstream flow conditions. field-replaceable. For best results, however, upstream and downstream straight pipe of five pipe diameters is recommended. DIMENSIONS SENSOR CONNECTION 12 ft. (3.66 m) ca P (Meter Thread, Male BSPP) Signal (-) Power (+) 5-30Vdc Dim. 1/2 Inch 3/4 Inch A B (with fittings) F (Male NPT) B C D E 3/4 in. BSPP 1 in. BSPP F 1/2 N PT 3/4 NPT ORDERING INFORMATION MODEL SEB SEB SIZE 1/2" = /4" = -075 ACCESSORIES Remote rate and total display = FT400 Series Pulse divider = PD ma output = A055W Provided / Distributed / Servi90 By: Phone: (800) (513)

96 SES Stainless Low Flow Meter FEATURES Accurate at low flows Simple and durable Rugged body High tolerance for problem fluids APPLICATIONS Low flow monitoring Chemical batching Proportional chemical injection Fertilizer injection GENERAL INFORMATION The SES low flow meter provides accurate, wide range flow metering in an extremely rugged stainless steel package. Single-jet simplicity combined with high quality jewel bearings results in long life and relatively high tolerance for problem fluids. Typical applications are chemical batching, proportional chemical injection, fertilizer injection, proportioning of spray chemicals, and general flow rate monitoring. The sensor is easily replaced from outside the meter, and is compatible with most of the Seanrietrics indicators and transmitters, as well as most controls and PLC's that accept DC inputs. The standard rotor is PVDF (Kynar) and the shaft is a special nickel-bonded tungsten carbide. The optional ceramic shaft increases resistance to some concentrated chemicals. The standard 0-ring is Teflon-coated Viton, with EPDM and Kalrez optional for compatibility with a variety of chemicals. 83 Provided / Distributed / Serviced By: Meters I Controls [Equipment I Service Phone: (800) (513)

97 Seametrics 18 Sensor Cable Thread-in Sensor, Field Replaceable, 6-24 Vdc pulse FIELD REPLACEMENT OF SENSOR 316 Stainless Steel Body Female NPT thread (SAE optional) Removeable 3165S Cover Flex Screws (Internal) Jewel Bearings Kynar/Carbide Rotor Assembly (Kynar/Ceramic optional) Teflon-coated Viton 0-Ring (EPDM or Ka lrez optional) SPECIFICATIONS* Connection Ports Sensor Cable Materials Body Rotor Shaft Bearings 0-Ring Cover 1/2", 3/4', and r female NPT thread (SAE optional) 18 feet standard (Maximum cable run 2000 ft.) 316 stainless steel PVDF (Kynar) Nickel-bonded tungsten carbide (ceramic optional) Ruby ring and ball Teflon-coated Viton (EPONI or Kalrez optional) 316 stainless steel Maximum Temperature 200' F (93' C) Maximum Pressure Accuracy Power 500 psi (35 bar) +/- 1% of full scale 5-24 Vdc, 2 ma min Outputs Current sinking pulse, 6-24 Vdc *Specifications subject to change Please consult our website for current data ( Provided / Distributed / Servtgal By: Phone: (800) (513)

98 SES Stainless Low Flow Meter FLOW RANGE Model 0 *K-Factor (pulses/gal) Gal/Min Ltter/Min *Nominal K-factors (based on averages) for standard 2-magnet model. Hign resolution (6-magnet) K-factors are approximately tripled. PRESSURE DROP CURVES DIMENSIONS FLOW (GPM) r A - - N I Female NPT thread size varies with size'. see chart below Size NPT Thread Size A B C 1/2 inch 1/2 inch /4 inch 3/4 inch SS 1 inch 1 inch m... Provided / Dist ibuted / Serviced By: Meters I Controls lequipment I Service Phone: (800) (513)

99 Seametncs ORDERING INFORMATION MODEL SES SIZE 112" ( GPM) = /4( GPM) = " ( GPM) = -100 OPTIONS Ceramic shaft = -01 Micropower pickup (Use w/f1450 or DL76 only) = -04 High resolution rotor = -13 Kalrez 0-ring = -59 Silicon carbide shaft = -68 EPDM 0-ring = -69 SES ACCESSORIES Rate and Total Indicator, DC powered = FT400 Series Rate and Total Indicator, Battery powered = FT450 Blind Analog Transmitter (4 to 20 ma) = A055 Batch Flow Processor = FT520 Data Logger = DL76 Plug-in Power Converter, Vac, 24 Vdc = PC3 Panel Mount Plug-in Power Converter, Vac, 24 Vdc = PC2 Provided / Distributed / Serviggi By: Meters I Controls [Equipment I Service Phone: (800) (513)

100 S-SERIES SPT, SPX Low Flow Meters FEATURES Accurate at low flows Simple and durable Compatible with a variety of chemicals Visual flow monitoring (SPX Only) APPLICATIONS Low flow monitoring Chemical batching Proportional chemical injection Fertilizer injection SPX SPT GENERAL INFORMATION These versatile impellerflowmeters are availalble in 3/8", 1/2, 3/4", and 1" nominal pipe sizes with female N PT threads (SAE optional). They employ jewel bearings to allow for very low minimum flow rates and superior life. With a body material of polypropylene, the SPX is an economical choice for metering water or low corrosion fluids. The lens cover is available in a choice of materials: acrylic for visual flow indication of low-corrosion fluids; polypropylene when more corrosion resistance is needed. The standard rotor assembly is Kynar with tungsten carbide shaft (ceramic shaft optional). The 0-ring is EPDM. The SPT offers greater chemical resistance with a Teflon body and cover, Teflon-coated Viton 0-ring, and standard Kynar/ ceramic rotor assembly (silicon carbide shaft optional). The pulse output of these meters is compatible with many differenttypes of controls, including a full range of Seametrics rate displays and controls. The Seametrics FT400 Series provides flow rate and total flow indication, with 4-20 ma output capability. The FT450 is a battery-operated rate & total display. For metering pump pacing or interfacing with lowspeed counters, the PD10 pulse divider is recommended. The A055 may be used for blind 4-20mA transmission. 87 Provided / Distributed / Serviced By: Phone: (800) (513)

101 Seametrics Thread-in Sensor, Field Replaceable, 6-24 Vdc pulse SPX 18' Sensor Cable Removeable Lens Assembly Standard Acrylic Top (SPX) Hex Screws Female NPT Ports (SAE optional) (Internal) Jewel bearings Kynar/Carbide or Kynar/Ceramic Rotor Assembly EPDM (SPX) or Teflon-coated Viton (SPT) 0-ring FIELD REPLACEMENT OF SENSOR SPECIFICATIONS* SPX SPT Connection Ports 3/8", 1/2, 3/4", 1", Female NPT thread (SAE optional) 3/8", 1/2", 3/4, 1-, Female NPT thread (SAE optional) Sensor Cable 18 feet standard (Maximum cable run 2000 ft.) 18 feet standard (Maximum cable run 2000 ft.) Materials Body Polypropylene TFE Teflon Rotor PVDF (Kynar) PVDF (Kynar) Shaft Nickel tungsten carbide (zirconia ceramic optional) Zirconla ceramic (silicon carbide optional) 0-Ring EPDM (tairez or Teflon-coated Viton optional) Teflon-coated Viton (EPDM or Kalrez optional) Bearings Ruby ring and ball Ruby ring and ball Cover Acrylic (Polypro optional) TFE Teflon Maximum Temperature 160 F(70' C) 180' F(82' C) Maximum Pressure 150 PSI (10 bar) 150 PSI (10 bar) Accuracy +1% of full scale +1% of full scale Power 5-24 Vdc, 2 ma min 5-24 Vdc, 2 ma min Outputs Current sinking pulse, 6-24 Vdc Current sinking pulse, 6-24 Vdc *Specifications subject to change Pfease consult our bsite for current data (vww.seametrics_com). Provided / Distributed / Sental By: Phone: (800) (513)

102 S-SERIES PresureDrop(PSI) SPT, SPX Low Flow Meters FLOW RANGE *K-Factor (pulses/gal) Gal/Min Llter/Min SPT SPX Model # *Nominal K-factors (based on averages) for standard 2-magnet SPT and SPX High resolution (6-magnet) K-factors are approximately tripled. PRESSURE DROP CURVES /8" /2" 14" Flow (GPM) DIMENSIONS 4.10 F2.25 (SPT)* (SPX) 2.20 *NOTE SPT cover screws are not recessed Female NPT 18 R. Cable t h r e a d size varies (standard) w i t h model #. See chart below 1,625 Model # NPT Thread Size /8" /2" /4" " 89 Provided / Distributed / Serviced By: Phone: (800) (513)

103 Seametrics ORDERING INFORMATION MODEL Polypro/Acrylic = SPX TFE Teflon = SPT SIZE 3/8" ( GPM) = -038 VT ( GPM) = /4" ( GPM) = " (0,5-40 GPM) = -100 OPTIONS Ceramic shaft (SPX) = -01 Micropower pickup (use with F1450 or DL76 only) = -04 Polypro cover (SPX) = -12 High resolution rotor = -13 Teflon-coated Viton 0-ring (SPX) = -25 Kalrez 0-ring = -59 Silicon carbide shaft = -68 EPDM 0-ring (SPT) = -69 ACCESSORIES Rate and Total Indicator, DC powered = FT400 Series Rate and Total Indicator, Battery powered = FT450 Blind Analog Transmitter (4 to 20 ma) = A055 Batch Flow Processor = FT520 Data Logger = DL76 Plug-in Power Converter, Vac, 24 Vdc = PC3 Panel Mount Plug-in Power Converter, Vac, 24 Vdc = PC2 Provided / Distributed / Sento' By: Phone: (800) (513)

104 Seametams Saving T Saving Money Conserving Resources 46"---. Savi Time Technology with a Mission info@seametrics.com nd Avenue South, Kent, W fax: Provided Distributed! Serviced By: Phone: (800) (513)

Flow Meter & Control Catalog

Flow Meter & Control Catalog 2013 Flow Meter & Control Catalog Seametrics Products are covered by a Two Year Limited Warranty policy. Please visit the Downloads section of our website for more information. www.seametrics.com Technology

More information

EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY

EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY EX80- SERIES ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX83 9 001:2008 ISO CERTIFIED COMPANY TABLE OF CONTENTS General Information Features,

More information

SeaMetrics Flow Meters and Flow Computers

SeaMetrics Flow Meters and Flow Computers Distributed Products Fact Sheet and Flow Computers WTP-PVC body turbine flow meter WT-S Stainless steel body turbine flow meter TX115/215 Hottap insertion turbine flow meter FT420 Looppowered flow computer

More information

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS Spec Tech Industrial 203 Vest Ave. Valley Park, MO 63088 Phone: 888 SPECTECH Email: sales@spectechind.com www.spectechind.com EM101 EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS LOW FLOW MAGNETIC FLOWMETER

More information

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE EM101 LOW FLOW MAGNETIC FLOW METER INSTRUCTIONS EM 101 LOW-FLOW MAGNETIC FLOW METER INSTRUCTIONS EM 101-025 EM 101-038 EM 101-050 GENERAL INFORMATION The EM101 is a small plastic-bodied electromagnetic

More information

imag 4700 SERIES FLANGED MAGMETER

imag 4700 SERIES FLANGED MAGMETER SERIES r (Remote Display) p Features Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated Right meter for Water & Wastewater Treatment Municipal

More information

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS -series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS -SERIES MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS 101 104 The Leader in Flow Meter Value Table of Contents General Information General Information,

More information

WMX-SERIES Flanged Magmeter

WMX-SERIES Flanged Magmeter 9001:2008 ISO CERIFIED COMPANY FEAURES NSF/ANSI 61 Available (3 only) Built-in pulse output for data logging or telemetry Minimal straight pipe required Continuous battery or external power IP68 submersible

More information

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS TX800-SERIES FLOW SENSOR INSTRUCTIONS TX800-Series FLOW SENSOR INSTRUCTIONS TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TABLE OF CONTENTS General Information Generial Information, Features...Page 3 Specifications...Page

More information

G2 Industrial Grade Meters

G2 Industrial Grade Meters G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine

More information

AG2000 Irrigation Magmeter

AG2000 Irrigation Magmeter 9001:2008 ISO CERIFIED COMPANY APPICAIONS Irrigation Chemigation Agricultural automation Well usage monitoring Dairy agoons FEAURES Simple as a mechanical meter No moving parts Minimal straight pipe required

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal

More information

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters ProSeries by Blue-White Industries, Ind. Ltd. Industries, Ltd. s SNIC-PR s SNIC-PR s S4 Transit Time Ultrasonic Flowmeter ½ thru 2 diameter Pipe Sizes Inline spool piece Advanced communications Data logging

More information

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value. E X S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s EX Series Electromagnetic FLOW SENSOR instructions EX EX The Leader in Flow Meter Value. Table of Contents General

More information

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA IP800-Series Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA ISO 9001:2008 Certified Company TABLE OF CONTENTS General Information General Information...Page 3 Features...Page 3

More information

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL From McCROMETER 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (95) 652-68 Toll Free (800) 220-2279 Fax

More information

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82 E X S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s EX Series Electromagnetic FLOW SENSOR instructions EX EX The Leader in Flow Meter Value. Table of Contents General

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

TURBINE METERS - WP Series

TURBINE METERS - WP Series TURBINE METERS - WP Series Operating Pressure 150 psi Maximum Operating Temperature Cold Water 105 F (40 ) 3 Layers Epoxy Coating SIZE 2" 3" 4" 6" 8" Max. Flow Rate GPM 400 850 1100 2600 4400 Transition

More information

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA IP800-Series Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA ISO 9001:2008 Certified Company TABLE OF CONTENTS General Information General Information...Page 3 Features...Page 3

More information

Time Delta S Fixed Transit-Time Flow Meter System

Time Delta S Fixed Transit-Time Flow Meter System Fixed Transit-Time Flow Meter System Key Features Dynamic flow correction Simple configuration Digital outputs Enhanced anti-bubble measurement technology (ABM) Rugged and reliable Maintenance free The

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS F- SERIES MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS TABLE OF CONTENTS General Information General Information, Features... Page 1 Specifications Specifications, Flow Range... Page 2 Installation and

More information

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS TX80-SERIES FLOW SENSOR INSTRUCTIONS TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX82 9 001:2008 ISO CERTIFIED COMPANY TABLE OF CONTENTS General Information Specifications, Features...Page 1 Installation

More information

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS IP80-SERIES FLOW SENSOR INSTRUCTIONS IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP82 9 001:2008 ISO CERTIFIED COMPANY TABLE OF CONTENTS General Information Features, Specifications...Page 3 Installation

More information

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS IP80-SERIES FLOW SENSOR INSTRUCTIONS IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP820 9001:2008 ISO CERTIFIED COMPANY TABLE OF CONTENTS General Information Features, Specifications...Page 3 Installation

More information

FT430/440/450 RATE/TOTAL INDICATOR INSTRUCTIONS

FT430/440/450 RATE/TOTAL INDICATOR INSTRUCTIONS FT430/440/450 RATE/TOTAL INDICATOR INTRUCTION FT430/440/450 RATE/TOTAL INDICATOR INTRUCTION Optional Protective Cover Closed 9001:2008 IO CERTIFIED COMPANY PROUDLY MADE IN THE UA TABLE OF CONTENT General

More information

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch. -SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS -Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 3 inch 2 inch 1 inch 9001:2008 ISO CERTIFIED COMPANY GENERAL INFORMATION and FEATURES GENERAL INFORMATION The -Series

More information

TX101/201 Insertion Turbine Instructions

TX101/201 Insertion Turbine Instructions TX101/201 Insertion Turbine Instructions General Information Ruby bearings and a non-drag pick-off give these adjustable insertion turbine flow sensors a wide flow and long life. A sensor detects the passage

More information

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe Portable Ultrasonic Flowmeters Models PT400 & PT500 Measure Flow of Clean Fluids in Full Pipes with Non-contacting Ultrasonic

More information

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter A trademark of Spirax Sarco, Inc. Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter Description The Hydro-Flow Model 2200 fixed insertion vortex flow meter was designed specifically for water flow measurement,

More information

flow x3 flow monitoring

flow x3 flow monitoring flow x3 flow monitoring The FlowX3 System includes a complete range of paddle wheel flow sensors, instruments and sensor installation fittings. Also included are insertion type electromagnetic flow transmitters.

More information

Signet 2551 Magmeter Flow Sensor

Signet 2551 Magmeter Flow Sensor Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No

More information

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS -SERIES FLOW SENSOR INSTRUCTIONS -Series FLOW SENSOR INSTRUCTIONS IP810 IP820 9001:2008 ISO CERTIFIED COMPANY TABLE OF CONTENTS General Information Features, Specifications...Page 3 Installation Insertion

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

Positive Displacement Flowmeters

Positive Displacement Flowmeters Positive Displacement Flowmeters SRZ series Helical screw positive displacement flowmeters Positive Displacement Flowmeters Two highly accurate cycloid-shaped screw spindles mesh and rotate inside a cylindrical

More information

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL From McCROMETER 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279 Fax (951) 652-3078

More information

2100 Turbine Flow Sensor

2100 Turbine Flow Sensor 200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3

More information

RESISTIVITY MONITOR/CONTROLLERS

RESISTIVITY MONITOR/CONTROLLERS RESISTIVITY MONITOR/CONTROLLERS Installation Operation Maintenance User Manual for Models: 750, 752, 753, 762 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel: 1-760-438-2021 Fax: 1-800-869-7668 / 1-760-931-9189

More information

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY EX100/200-SERIES INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX250 9 001:2008 ISO CERTIFIED COMPANY TABLE OF CONTENTS General

More information

MFM220 & MFM220DC Plastic-Bodied Magmeter

MFM220 & MFM220DC Plastic-Bodied Magmeter APPLICATIONS Usage monitoring, such as: Industrial wastewater discharge monitoring Cooling tower deduct metering Heap leach mining discharge monitoring Well monitoring Turf and landscape water monitoring

More information

PSF50 Paddle flow switch

PSF50 Paddle flow switch Paddle Flow Switch Paddle Flow Switch PSF50 Paddle flow switch Paddle flap flow / no flow switch Economically priced flow/no flow paddle operated flow switch. Simple and reliable design for liquids up

More information

AG2000 IRRIGATION MAGMETER INSTRUCTIONS

AG2000 IRRIGATION MAGMETER INSTRUCTIONS AG2000 IRRIGATION MAGMETER INSTRUCTIONS AG2000 IRRIGATION MAGMETER INSTRUCTIONS FEATURES Rate and total indicator Powder-coated diecast-aluminum electronics housing Cross-drilled screws (2) for tamper-evidence

More information

TX101/201 Insertion Turbine Instructions

TX101/201 Insertion Turbine Instructions TX101/201 Insertion Turbine Instructions General Information Sapphire bearings and a non-drag pick-off give these adjustable insertion turbine flow sensors a wide flow and long life. A Hall-effect device

More information

Hydro-Flow Model 2200 Installation and Operation Guide B

Hydro-Flow Model 2200 Installation and Operation Guide B Hydro-Flow Model 2200 Installation and Operation Guide 5700507-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Making Electrical Connections. 7 Mechanical and Electrical

More information

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.

More information

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO Digital Paddlewheel Flow meter Operating Manual Blue-White Industries, Ltd. Page 2 TABLE OF CONTENTS 1...Introduction...2 2...Features...3 3...Model number matrix...3 4...Specifications...4 4.1..Temperature

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

TX115/215 Hot-tap Insertion Turbine Instructions

TX115/215 Hot-tap Insertion Turbine Instructions TX115/215 Hot-tap Insertion Turbine Instructions General Information These hot tap versions of the proven TX insertion flow sensors are designed to install or be serviced without depressurizing the pipe.

More information

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines 4 Mechanical Drawing:

More information

Options guide. Electromagnetic flowmeters. M9xx

Options guide. Electromagnetic flowmeters. M9xx Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910

More information

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen Measurement System with Air Blast Cleaner Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting

More information

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008 Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com GTFM IV Gas Turbine Flow Monitor Operation / Installation

More information

INSTRUMENTATION & CONTROL

INSTRUMENTATION & CONTROL Irrigation Controller.................... 172 Window Controller.................... 174 Water Meter Controller.................. 176 Digital Level Switch.................... 177 Filtration Controller Set..................

More information

Cerama~Flow CF900. Wear Resistant Magnetic Slurry Flowmeter. Superior Measurement Systems.

Cerama~Flow CF900. Wear Resistant Magnetic Slurry Flowmeter. Superior Measurement Systems. Cerama~Flow CF900 Wear Resistant Magnetic Slurry Flowmeter Superior Measurement Systems www.hmagroup.com.au Technical Specification NautiFlow NF-1 Battery Powered Electromagnetic flowmeter Intelligent

More information

Product Summary. Flow Meters. Hydraulic Diagnostic Products

Product Summary. Flow Meters. Hydraulic Diagnostic Products Product Summary Flow Meters TM Hydraulic Diagnostic Products RACINE FEDERATED INC. ISO 91 : FILE N. A6856 Variable Area Flow Meters Basic In-line Flow Meters Hedland offers a complete line of over 15,

More information

Instructions EM 101 Low Flow Electromagnetic Flow Meters

Instructions EM 101 Low Flow Electromagnetic Flow Meters PDF Published June 3, 2004 Instructions EM 101 Low Flow Electromagnetic Flow Meters Installation Mounting The EM 101 model has a flow meter unit and a separate control unit containing a LCD display. The

More information

Hot Tap Insertion Vortex

Hot Tap Insertion Vortex Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design

More information

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue Flow Meters & Instruments Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments Technical Catalogue PDF Published October 19, 2017 flow sensors Type F3.01 Direct Mount Flow Sensors

More information

TYPE MP OSCILLATING PISTON FLOWMETER

TYPE MP OSCILLATING PISTON FLOWMETER TS-150 (G) TYPE MP OSCILLATING PISTON FLOWMETER Flow Rates of 3.8 to 1,140 Liters/Min. (1 to 300 gpm) Accuracy of ±0.5% of Rate ±0.1% Repeatability Magnetically Coupled Output Shaft Proven Reliable Oscillating

More information

Ultra Mag SUBMITTAL PACKAGE

Ultra Mag SUBMITTAL PACKAGE SUBMITTAL PACKAGE Date: McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 PHONE (951) 652-6811 TOLL FREE (800) 800-8804 FAX (951) 652-3078 www.mccrometer.com 3255 WEST STETSON AVENUE HEMET, CALIFORNIA

More information

Insertion Flow Meters. Municipal Market Customer Presentation

Insertion Flow Meters. Municipal Market Customer Presentation Insertion Flow Meters Municipal Market Customer Presentation Topics for Discussion Product Description Product Offering Product Name Principal of Operation Why the New FPI Mag? Development Team Comparison

More information

OM004, OM006 & OM008 Oval Gear Meter

OM004, OM006 & OM008 Oval Gear Meter OM SERIES OM004, OM006 & OM008 Oval Gear Meter OM004 (1/8"), OM006 (1/4") and OM008 (3/8") Oval Gear Meters ACCURACY: ±1.0% OF READING Select Your Body Material: Aluminum or Stainless Steel The OM Small

More information

Marsh McBirney Flo-Dar

Marsh McBirney Flo-Dar Marsh McBirney Flo-Dar Accurate Flow Measurement Flo-Dar TM provides the user with highly accurate flow measurements under a wide range of flows and site conditions. By measuring the velocity of the fluid

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

A1 Commercial Grade Meters

A1 Commercial Grade Meters A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

TX 115/215 Hot-tap Insertion Turbine Instructions

TX 115/215 Hot-tap Insertion Turbine Instructions TX 115/215 Hot-tap Insertion Turbine Instructions General Information These hot tap versions of the proven TX insertion flow sensors are designed to install or be serviced without depressurizing the pipe.

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

A1 Commercial Grade Meters

A1 Commercial Grade Meters A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like

More information

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS HIGH TEMPERATURE SENSORS AS STANDARD FOR PERMANENT INSTALLATION ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS The Ultraflo 2000 is a Transit Time ultrasonic

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401 P/N 1400 (Rev. A 08/12) NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401 User Guide Table of Contents Introduction... 2 Dimensions... 3 Installation... 5 Provided Equipment... 5 Operating Environment...

More information

DIFFERENTIAL PRESSURE BATTERY CHARGERS

DIFFERENTIAL PRESSURE BATTERY CHARGERS DIFFERENTIAL PRESSURE BATTERY CHARGERS CONVERTING PIPELINE ENERGY TO BATTERY POWER Free Uninterruptible Power 24/7 ISO 9001:2008 Certified Quality System 10-20 Watt Units Available POWER SYSTEMS 12 or

More information

Range of Ultrasonic Flowmeters.

Range of Ultrasonic Flowmeters. Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters

More information

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP DESCRIPTION The MEMFlo MFTV Metal Bodied Flow Meters with Clear Top are simple, accurate, meters for use in a wide range of industrial liquid and gas

More information

KEL. Heavy Duty Differential Pressure Flowmeters

KEL. Heavy Duty Differential Pressure Flowmeters Heavy Duty Differential Pressure Flowmeters measuring monitoring analyzing KEL Rugged Metal Construction Flow Rates up to 2000 GPM Linear Scales For Horizontal or Vertical s Threaded or Wafer Style s Able

More information

Model FVP General Specification. Flanged Vortex Plate. Product Features

Model FVP General Specification. Flanged Vortex Plate. Product Features Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from

More information

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS COMMERCIAL GRADE METERS Look for the silver label! Look for the silver label! COMMERCIAL GRADE METERS Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters

More information

INDUSTRIAL DYNAMICS CO

INDUSTRIAL DYNAMICS CO TS-150 Rev. B MP Oscillating Piston Flowmeter: 12.7 mm (1/2" Type MP) 25.4 mm (1" Type MP) 50.8 mm (2" Type MP) 76.2 mm (3" Type MP) TYPE MP OSCILLATING PISTON FLOWMETER 2 " Type MP with 800 Series Register,

More information

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement Sensing the pulse of industry tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement tekflo sensors are proud to present their tekson TS Series ultrasonic water energy meter, which uniquely

More information

Full Profile Insertion

Full Profile Insertion FPI Mag Meter Full Profile Insertion High Performance Electromagnetic Flow Meter Municipal Market Product Presentation Manufactured exclusively by McCrometer, Inc. Hemet, CA USA 55+ Years of Experience

More information

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer Datum Electronics has further extended its standard range of torque transducers to cater for higher rotary speeds and an increased number of torque ranges. The 420 Series torque transducers operate with

More information

Flow meter Type Recordall (RCDL)

Flow meter Type Recordall (RCDL) Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Flow meter Type Recordall (RCDL) Bronze model Features

More information

Turbidity and Suspended Solids Transmitter

Turbidity and Suspended Solids Transmitter Data Sheet 5.1 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. DK: NO: SE: NL: USA: AUS: +45 45 56 06 56

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

digital flow meters BW Digi-Meter F-1000

digital flow meters BW Digi-Meter F-1000 F-1000 Series paddle wheel flow meters provide the performance and features of electronic meters, without the need for an external electricity supply. A large range of installation tees and saddles enables

More information

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V SOLAR LIGHTING CONTROLLER OPERATOR S MANUAL SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V 10A / 12V 10A / 24V 20A / 12V 20A / 24V 1098 Washington Crossing Road Washington Crossing,

More information

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document. General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Features and functions Power supply Standard

More information

Industrial OG meter series IOG Inline and flanged oval gear meter

Industrial OG meter series IOG Inline and flanged oval gear meter Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Industrial OG meter series IOG Inline and flanged oval

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

Insertion magnetic inductive flowmeter

Insertion magnetic inductive flowmeter Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

MagFlux Q 8200 Series

MagFlux Q 8200 Series MagFlux Q 8200 Series 3.06 ELECTROMAGNETIC FLOW METER General MagFlux Q Electromagnetic Flow Meter, created in composite materials, designed with an optimized construction which secures optimal performance.

More information

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at Installation Manual INTRODUCTION The full WeatherTRAK Flow Installation and Maintenance Manual is available online at www.weathertrak.com General Description A WeatherTRAK Flow combines a hydraulic master

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

Principle of Operation

Principle of Operation Turbine Flow Meters Flow Technology Turbine Flow meters are commonly used in mission critical applications demanding superior accuracy, quality and reliability. Ideal for clean liquids and gases, such

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information