FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

Size: px
Start display at page:

Download "FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL"

Transcription

1 FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL From McCROMETER 3255 WEST STETSON AVENUE HEMET, CA Phone (95) Toll Free (800) Fax (95) Date:

2 Project Name: Purchase Order No.: Date: Customer Name: Submitted By: Other Project Information: Page

3 Equipment to be Supplied to McCrometer, Inc. PART NUMBER DESCRIPTION METER QTY. METER 2 QTY. METER 3 QTY. Model 395L FPI Mag Meter Forward Flow Model 394L FPI Mag Meter Bidirectional Flow Nominal Pipe Size in inches (4 to 38 ) () M-Series Electronic Unit, including: () IP67 Enclosure () Three-Button Key Pad () Back-Lit Graphical LCD Display (4) Programmable Opto-Isolated Digital Outputs (2) 4-20mA Programmable Output for Forward Flow () VAC Powered () Electromagnetic Averaging Sensor, including: () 2 Stainless Steel Full Port Ball Valve with () 2 x Close Stainless Steel Nipple () 3M Fusion Bonded Epoxy Protective Coating () Quick Connect Cable Connector (IP68) (20) Feet of Submersible Sensor Cable () Compression Seal () Set of Retaining/Installation Rods () Top Plate () Instruction Manual BUILT-IN OPTIONS Additional Sensor Cable: Specified Total Length In Feet (Leave Blank For None) Special 0 to 35 VDC Powered Special Compression Gland Seals (instead of Quick Connects at sensor) ACCESSORIES 7503/75032 Insertion Tool 0624B33900 Sun Shield Stainless Steel Tag i IMPORTANT: The MINIMUM port inside diameter for all installation valves is -7/8" (48mm). Page 2

4 PROJECT NOTES Meter : Meter 2: Meter 3: Page 3

5 FPI Mag Models 394L and 395L Suggested Specifications GENERAL The magmeter shall consist of two components; an electromagnetic averaging sensor and a converter unit. The magmeter shall automatically sense and correct for shifting velocity profiles in the pipe by constantly obtaining an area weighted mean velocity. The meter shall be equivalent to the Models 394L and 395L FPI Mag Full Profile Insertion Electromagnetic Flow Meter as manufactured by McCrometer, Inc. in Hemet, California. CONVERTER The flow meter converter shall be microprocessor based with a keypad for instrument set up and LCD displays for totalized flow, flow rate engineering units and velocity. The converter shall power the flow-sensing element and provide a galvanically isolated Dual 4-20mA output. It shall be possible, in the test mode; to easily set the converter outputs to any desired value within the range. The 4-20mA scaling, time constants, pipe size, flow proportional output, engineering units and test mode values shall be easily set via the keypad and display. Four separate fully programmable alarm outputs shall be provided to indicate empty pipe, forward/reverse, polarity (normally open/close), analog over-range, fault conditions, high/low flow rates, % of range, and pulse cutoff. The converter shall periodically perform self-diagnostics and display any resulting error messages. All set up data and totalizer values may be protected by a password. SENSOR The flow-sensing element shall be of an electromagnetic averaging type design and factory calibrated to NIST traceable standards. The flow sensor shall also be supplied with a stainless steel full port ball valve or corporation stop and stainless steel nipple. Installation of the averaging sensor shall be accomplished either under flowing conditions or in a dry line through a 2-inch tap via a full port ball valve or corporation stop into the pipe. Profiling or site calibration shall not be required. Measuring electrodes and reference ground electrodes shall be constructed of 36 stainless steel for corrosion protection against the passing fluid. Sensor shall have epoxy coating over the stainless steel to help from attack of UV, chemical resistance and excess buildup. Sensor shall be suitable for clean, potable, raw (check algae content) or other debris-free water applications. The sensor shall not be damaged by extended operation at partially full or empty pipe conditions. SENSOR CABLES The sensor shall have dual cables of 20 feet of multi-conductor; abrasive resistant, PVC jacketed, submersible cable flexible to -40 F. The sensor cables shall have quick connect attachments, or optional compression gland seas. Both cable connections are IP68 rated. Additional cable length up to a maximum of 500 feet shall be available as an option. MOUNTING HARDWARE Stainless steel threaded retaining rods, of sufficient length, shall be provided for the smooth installation of the electromagnetic averaging sensor. Shorter stainless steel retaining rods shall also be provided for the continuous operation of the electromagnetic averaging sensor. In order to provide stable and secure sensor placement, the sensor shall be capable of compression up to 300 lbs. for use in low pressure PVC pipes and 450 lbs. for use in low pressure metal pipes. For applications other than low pressure, contact factory for compression instructions. Page 4

6 FPI Mag Models 394L and 395L Suggested Specifications with Converter DESCRIPTION The full pipe averaging flow meter comes complete with Mounting Hardware, AC Converter with Single or Dual 4-20mA output, 25 Feet of Dual Submersible Cables with quick connects at sensor, Stainless Steel Body, 36 Stainless Steel Electrodes, NSF Approved Fusion Bonded Epoxy Coating, 2 Stainless Steel Ball Valve (minimum of -7/8 port I.D.), 2 x Close Stainless Steel Nipple, 2-Year Warranty. MEASUREMENT Volumetric flow in filled flow conduits 4 (00 mm) to 38 (3,500 mm) utilizing insertable electromagnetic averaging sensor. Flow indication in English Standard or Metric units. FLOW MEASUREMENT Method: Electromagnetic Calibrated Accuracy for Forward and Bidirectional Sensors: ± 0.5% from f/s to max velocity (on next page), up to ± % for 0.3 to f/s; ± % for battery powered converter, ± % for reverse flow Linearity: 0.3% of Range Repeatability: 0.2% of Reading Direction Measurement: 395L sensor - Forward flow measurement and reverse flow indication; 394L sensor - bidirectional flow measurement POWER SOURCE AC: VAC / Hz (20 W/25 VA) DC: 0-35 VDC (2 W) Battery: (for forward flow only) Estimated five year life span. (Battery life dependent on application. Estimated life based on factory standard settings) Solar panel option available. AC, DC, or battery must be specified at time of ordering. MATERIALS Fusion bonded epoxy (NSF 6 approved) coated 36 stainless steel Insertion Hardware: 36 Stainless Steel Compression Seal: Silicone Rubber Sensor Electrodes: 36 Stainless Steel STANDARD OUTPUTS: Single or Dual mA Outputs: Galvanically isolated and fully programmable for zero and full scale (0-2mA rangability) Two or Four 2 separate digital programmable outputs: open collector transistor usable for pulse, frequency, or alarm settings. Volumetric Pulse Flow Rate (Frequency) Hardware Alarm High/Low Flow Alarms Empty Pipe Maximum switching voltage: 40 VDC Maximum switching current: 00mA Maximum switching frequency: 250 Hz Insulation from other secondary circuits: 500V OPTIONAL OUTPUTS: Modbus Profibus 2 HART 2 Smart Output (Sensus or Itron) Directional Indication Range Indication Available with Single or Dual 4-20mA. 2 Available with Single 4-20mA only. Forward flow only. Not available with battery powered ISOLATION All inputs / outputs are galvanically isolated from power supply up to 500 V ENGINEERING UNITS Cubic Meter; Cubic Centimeter; Milliliter; Liter; Cubic Decimeter; Decaliter; Hectoliter; Cubic Inches; US Gallons; Imperial Gallons; Cubic Feet; Kilo Cubic Feet; Standard Barrel; Oil Barrel; US Kilogallon; Ten Thousands of Gallons; Imperial Kilogallon; Acre Feet; Megagallon; Imperial Megagallon; Hundred Cubic Feet, Megaliters CONDUCTIVITY Minimum conductivity of 5µS/cm CONVERTER ENCLOSURE IP67 Die Cast Aluminum 5.75 H x 5.75 W x 6.69 D (4.6 cm H x 4.6 cm W x 7 cm D) ELECTRICAL CONNECTIONS Sensor: Quick-Connect (IP68) Converter: Compression gland seals for 0.25 to diameter round cable. RATINGS IP68 Submersible Sensor (details below) IP67 Die Cast Aluminum Converter IP65 Panel Mount Converter C US CERTIFICATIONS AND APPROVALS ISO 900:205 certified quality management system NSF / ANSI 6 & NSF / ANSI 372 approved Listed by CSA to 600-; Certified by CSA to UL 600- COMPONENT and CSA C22.2 No CE: compliant (converter only) Note: Panel mount converter is not CSA approved. ENVIRONMENTAL Sensor: Flow temperate range 4 to 70 F (-0 to 77 C) up to 250 PSI Submersibility: Remote sensor is continuously submersible (IP68), with a standard quick-connect cable to 6 ft., and optional strain relief at 30 ft; die cast aluminum converter is rated IP67 Electronics: Operating and storage temperature: -4 to 40 F (-20 to 60 C) Storage: During freezing conditions and when meter is not in use, sensor must be removed from pipe and stored in dry conditions. NOTE: Damage to the sensor caused by allowing the sensor freeze in the pipe is not covered by the warranty. SYSTEM OPTIONS FORWARD AND BIDIRECTIONAL Hastelloy Electrodes Extended Warranties DC Power Extension to hardware clearance Sun Shield Annual Verification / Calibration Additional sensor cable up to 480 Sensor Insertion Tool (Max 500 ) Stainless Steel ID Tag KEYPAD AND DISPLAY Can be used to access and change set-up parameters using three membrane keys and an LCD display I A P M O R & T NSF / ANSI 6 & NSF / ANSI 372 Page 5

7 FPI Mag Model 395L and 394L Meter Technical Information 4.6 cm 5.75" 7.0 cm 6.69" Top Plate Captive Nut, Bearing and Bearing Retainer 23 cm 9.06" 4 cm 5.75" 3.8 cm 5.44" Insertion Rods 3.8 cm 5.44" 2.50 cm.98" M-SERIES CONVERTER DIMENSIONS Sensing Electrode Pairs Fluid Column Grounds Compression Seal (Inside Assembly) Reference Ground Electrodes Are Located On The Back Side Of The Sensor Compression Seal Assembly Locking Cotter Pin SENSOR ASSEMBLY INSTALLATION TOOL (OPTIONAL) Specialized sensor insertion tool used for installation, profiling, and maintenance of the sensor. SUN SHIELD (OPTIONAL) Page 6

8 3. Terminal Block Diagram FPI Mag Electrical Cable Connections All connections are made on the terminal blocks. To access the terminal blocks, loosen the four screws on the back of the converter to remove the rear cover. NOTE: The terminal blocks unplug from the circuit board for easy connection. DIP switch settings: There is no access to the programming menu when either switch or 2 set to the ON position. DIP switch Note: Must be in OFF (down) position to access menu. IF2 socket Note: Factory use only Signaling LED Note: When DC, this connector is red. When AC, the connector is green. FORWARD ELECTRODES EF E2F C SH SH COLLECTORS OUT OUT2 OUT3 OUT4 C C2 C3 C4 EMITTER OUT OUT2 OUT3 OUT4 E RS485 B A GND SH NOTE: Jumper between 7 & 8 is only used with the 394 bidirectional flow meter Power Supply LED status: Constant ON: Converter start up second flashing: Normal operation (no alarms) Rapid flashing: Alarm condition 4-20 ma Out Terminals See Section 3.4 for instructions for connecting the forward and reverse 4-20mA outputs and proper removal of load resistors. E2R ER C SH REVERSE ELECTRODES This terminal block is only used for the 394L bidirectional meter. SH B B2 COILS - INP Figure 6. Terminal Block Diagram 24V SH OUTF* OUT2R* 4-20m -24V OUT OUT2 4-20mA COMMON Page 7

9 FPI Mag Model 394L Electrical Cable Connections FPI MAG 394L Bidirectional Sensor Black Ground To Chassis Lug CHASSIS BLACK BLUE PINK BLACK JUMPER GREEN/YELLOW GREEN/YELLOW RED YELLOW Figure 9. Ultra Mag Body Style Sensor Cable Connections Cable Diameters: Cable A (5035): Cable B (5036): Terminal Block Assignments Cable Terminal Wire Color A # (EF) Blue A #2 (E2F) Pink B #3C Black A #4 (SH) Green/Yellow B Chassis Lug Black B #9 (SH) Green/ Yellow B #20 (B) Red B #2 (B2) Yellow FPI MAG 395L Forward Only Sensor Ultra Mag Body Style 2: 4" through 2" ` i *IMPORTANT: See Section 3.3, Figure 3 for instructions on attaching the chassis ground wire to the converter ground lug. Black Ground To Chassis Lug CHASSIS BLACK BLUE PINK BLACK GREEN/YELLOW GREEN/YELLOW RED YELLOW Figure 0. Ultra Mag Body Style 2 Sensor Cable Connections Terminal Block Assignments Terminal Cable Wire Color # (EF) A Blue #2 (E2F) A Pink #3 (C) A Black #4 (SH) A Green/Yellow Chassis Lug B Black #9 (SH) B Green/ Yellow #20 (B) B Red #2 (B2) B Yellow Page 8

10 4-20mA Hook-Up 4-20mA Hook-Up Isolated 4-20mA current loops are used to output flow data to external devices. Maximum load impedance is,000ω, and the maximum voltage without load is 27VDC. The converter has the capability to detect a loss of load on this output. To disable this function set the value ma Val. Fault under the ALARMS menu to zero (See Section 8.4.6). A graphical example of the usage of the current loop with external device is shown below: - Terminal 25 FORWARD FLOW OUT 4-20mA 4-20mA Devices - Terminal 26 REVERSE FLOW OUT2 4-20mA Terminal 27 COMMON OUT / OUT2 4-20mA i IMPORTANT - RESISTOR REMOVAL FOR 4-20mA OUTPUTS It is required to remove the resistors from terminals 25 & 27 and/or 26 & 27 before attaching 4-20mA cables. FORWARD FLOW: Remove the resistor from terminals 25 and 27. REVERSE FLOW: Remove the resistor from terminals 26 and 27. See Section 4.2 Terminal Board, Figure 5. Figure 5: 4-20mA Hook-Up If the external device requires a voltage input, a precision resistor placed across the input terminals of the external device will change the current to voltage. Calculate the required resistor using Ohm s law (V = I x R). For example, a 250Ω resistor will provide an input voltage of one to five volts with the transmitter range being set from 4mA to 20mA. An additional 4 to 20mA loop output is available. i IMPORTANT The converter powers the 4-20mA loops. Do not use external power for the 4-20mA loop as it may cause permanent damage to the converter. Page 9

11 Opto-Isolated Pulse Output Hook-Up Opto-Isolated Pulse Output Hook-Up The four outputs are open collector transistor outputs used to communicate with or activate external devices when the flow reaches a predetermined set point. Opto-isolated output with collector and emitter terminals floating and freely connectable Maximum switching voltage: 40 VDC Maximum switching current: 00mA Maximum saturation voltage between collector and emitter.2v@00ma Maximum switching frequency (load on the collector or emitter, RL=470Ω, VOUT=24VDC): 250Hz Maximum reverse current bearable on the input during an accidental polarity reversion (VEC): 00mA Insulation from other secondary circuits: 500 V A common application of outputs should be connected as follows: Examples Of Types Of Input Devices OUTPUTS - Terminal 6 OUT C Pulse Input - Terminal 7 OUT2 C2 Frequency Input - Terminal 8 OUT3 C3 Alarm Input - Terminal 9 OUT4 C4 i Alarm Input IMPORTANT Power Source: The power source can be internal or external. - Opto-Isolated Pulse Output Diagram Terminal 0 EMITTER COMMON Outputs are not isolated from each other. All outputs MUST use the same power source. Page 0

12 Converter Power Hook-Up! Converter Power Hook-Up WARNING!! Hazardous supply voltage can shock, burn, or cause death. The power supply line must be equipped with external surge protection for current overload (fuse or circuit breaker with limiting capacity not greater than 0A). It must be easily accessible for the operator and clearly identified. Power connection is made using the power terminal block on the upper right side of the terminal board. NOTE: The terminal block uplugs from the circuit board for easy connection. Connect earth ground to the protective grounding terminal before making other connections. The power supply of a standard converter is VAC, 44-66Hz at maximum 20W. DC converter is available as an option. Neutral Wire Typically A White Wire Negative Wire Typically A White Wire Line Wire Typically A Black Wire L N Ground Wire Typically A Green Wire Positive Wire Typically A Black Wire - Ground Wire Typically A Green Wire AC Power Supply Terminal Block Optional DC Power Supply Terminal Block Page

13 SPECIFICATION DATA SHEET NOTE: All Blue Fields are Mandatory. Custom sensors cannot be manufactured without this information. Models 394L and 395L End User Name End User End User Phone FPI Site Address Site Name (Ex. Well #) Application (Ex. Well Output) Meter Fluid (Ex. Raw Water) Direction 395L Forward 394L Bidirectional Electrodes Converter Power Converter Options* Datalogger Cathodic Protection Sensor Cable Connection Sensor Cable Length in Feet *See Configuration Sheet (Lit# ) for converter information. 0 Units of Measure: ID Inside Pipe Diameter (Not Nominal Pipe size) A Critical Spacing (Reference Only) A B E F C T D H B C D 0 Date received by McCrometer Maximum Flow (Ex GPM) Minimum Flow (Ex. 00 GPM) Average Flow (Ex. 500 GPM) Full Scale (Ex GPM) Maximum Line Pressure (PSI or kpa) Maximum Temperature ( C or F ) Authorized Customer Signature: The above signature authorizes McCrometer to rely upon the provided specifications. PRICE: PRICING EFFECTIVE JULY 7, 207 Per FPI Price List, Lit.#245 4, Rev. 3. Subject to change without notice. Prices F.C.A. Seller s Premises Compression Seal Height (.5 for 24.99, 3.5 for ) Valve Height (McCrometer supplied valve = 5.0 or specify) Close Nipple and Coupling/Saddle Height (*McCrometer Supplied Close Nipple is.0 Industry Standard Coupling or Saddle Default =.5 ), OR Customer Supplied Dimension Pipe Wall Thickness Default.0 OR Customer Supplied Dimension F = A B C D E T = F ID (in Inches) T = Total Sensor Length ( F ID ) Model: Calculated Distance When Close to an Obstruction ( T C D 8 ) T F E ***Verify Clearance H Obstruction ***Consult Factory if Obstruction is closer to pipe than Distance "H". i *IMPORTANT: The MINIMUM inside diameter (ID) for the installation valve and pipe cut out to avoid damage to the sensor is 7/8. Page 2

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL From McCROMETER 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279 Fax (951) 652-3078

More information

Ultra Mag SUBMITTAL PACKAGE

Ultra Mag SUBMITTAL PACKAGE SUBMITTAL PACKAGE Date: McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 PHONE (951) 652-6811 TOLL FREE (800) 800-8804 FAX (951) 652-3078 www.mccrometer.com 3255 WEST STETSON AVENUE HEMET, CALIFORNIA

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

Full Profile Insertion

Full Profile Insertion FPI Mag Meter Full Profile Insertion High Performance Electromagnetic Flow Meter Municipal Market Product Presentation Manufactured exclusively by McCrometer, Inc. Hemet, CA USA 55+ Years of Experience

More information

Appendix. Clearance. Skewed profiles. Application Schematics

Appendix. Clearance. Skewed profiles. Application Schematics Appendix Application Schematics The purpose of the application schematics is to show different applications and the best sensor location for a particular application. Clearance Because the sensor will

More information

Insertion Flow Meters. Municipal Market Customer Presentation

Insertion Flow Meters. Municipal Market Customer Presentation Insertion Flow Meters Municipal Market Customer Presentation Topics for Discussion Product Description Product Offering Product Name Principal of Operation Why the New FPI Mag? Development Team Comparison

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

imag 4700 SERIES FLANGED MAGMETER

imag 4700 SERIES FLANGED MAGMETER SERIES r (Remote Display) p Features Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated Right meter for Water & Wastewater Treatment Municipal

More information

ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL 30119-03 Rev. 4.8 April, 2013 TABLE OF CONTENTS Section Page 1. INTRODUCTION...1 1.1 Description...1 1.2 Uncrating...1 1.3 Serial

More information

Rosemount 8750WB Magnetic Flowmeter System

Rosemount 8750WB Magnetic Flowmeter System Rosemount 8750WB Magnetic Flowmeter System for Utility, Water, and Wastewater Applications Product Data Sheet 00813-0200-4750 Rev AA THE 8750W MAGNETIC FLOWMETER Rosemount reliability customized for Water,

More information

Hydro-Flow Model 2200 Installation and Operation Guide B

Hydro-Flow Model 2200 Installation and Operation Guide B Hydro-Flow Model 2200 Installation and Operation Guide 5700507-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Making Electrical Connections. 7 Mechanical and Electrical

More information

Flow Measurement Solutions for Water & Waste Water INSTALLATION OPERATION & MAINTENANCE MANUAL

Flow Measurement Solutions for Water & Waste Water INSTALLATION OPERATION & MAINTENANCE MANUAL Flow Measurement Solutions for Water & Waste Water INSTALLATION OPERATION & MAINTENANCE MANUAL Table of Contents SECTION 1 - INTRODUCTION Specifications... 2 Dimensions... 2 Flow Ranges... 2 SECTION 2

More information

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been established over the last 80 years. The electromagnetic

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines 4 Mechanical Drawing:

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE EM101 LOW FLOW MAGNETIC FLOW METER INSTRUCTIONS EM 101 LOW-FLOW MAGNETIC FLOW METER INSTRUCTIONS EM 101-025 EM 101-038 EM 101-050 GENERAL INFORMATION The EM101 is a small plastic-bodied electromagnetic

More information

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS Spec Tech Industrial 203 Vest Ave. Valley Park, MO 63088 Phone: 888 SPECTECH Email: sales@spectechind.com www.spectechind.com EM101 EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS LOW FLOW MAGNETIC FLOWMETER

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

Propeller. Flowmeter. Technology. For the Real World.

Propeller. Flowmeter. Technology. For the Real World. Propeller Flowmeter Technology For the Real World. Propeller Flowmeters Long-lasting Stainless Steel Ball Bearings. Factory lubricated and protected from flow stream. Epoxy-Coated Carbon Steel Body. All

More information

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines Mechanical Drawing:

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

Hydro-Flow Model 3100

Hydro-Flow Model 3100 Hydro-Flow Model 3100 Installation and Operation Guide installation and operation guide Contents: Understanding Your Flow Meter... 1 Identifying Your Flow Meter...2 Installing Your Flow Meter...3,4 Making

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter A trademark of Spirax Sarco, Inc. Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter Description The Hydro-Flow Model 2200 fixed insertion vortex flow meter was designed specifically for water flow measurement,

More information

Instructions EM 101 Low Flow Electromagnetic Flow Meters

Instructions EM 101 Low Flow Electromagnetic Flow Meters PDF Published June 3, 2004 Instructions EM 101 Low Flow Electromagnetic Flow Meters Installation Mounting The EM 101 model has a flow meter unit and a separate control unit containing a LCD display. The

More information

M3500 Industrial Pressure Transmitter

M3500 Industrial Pressure Transmitter M3500 Industrial Pressure Transmitter The M3500 is a high accuracy industrial pressure transmitter featuring HART communications and a cast aluminum enclosure for indoor or outdoor use. Typical output

More information

DURA MAG BATTERY POWERED ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL Rev. 1.

DURA MAG BATTERY POWERED ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL Rev. 1. DURA MAG BATTERY POWERED ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL 30122-53 Rev. 1.3 October 23, 2018 Contents 1.0 INTRODUCTION...1 1.1 Safety Symbols And Warnings...1 1.2

More information

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen Measurement System with Air Blast Cleaner Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting

More information

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device 2SGT Electronic Pressure Instrument Three Separate Functions in a Single Loop-Powered Device Switch Two Independent, Programmable SPST Solid State Relays Program switch open and close values in engineering

More information

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES: KMS501W & KMS502F- TW FEATURES: Fitted with Sydney Water Tradewaste plugs (Sampler and ma outputs). For waste water, bore water and irrigation ( upto 10% solids). Unsurpassed accuracy to ±0.5% 0.5 m/s

More information

Model 395L Full Profile Insertion Electromagnetic Flowmeter Forward Flow

Model 395L Full Profile Insertion Electromagnetic Flowmeter Forward Flow Model 395L Full Profile Insertion Electromagnetic Flowmeter Forward Flow Installation, Operation and Maintenance Manual 24511-19 Rev. 1.4 June, 2012 CONTENTS 1.0 Safety Warnings... 1 1.1 Safety Symbols

More information

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date FLOWMETRIX SA Doc Date 17.07.2012 PERFORMANCE * 0,5% of rate (Standard) * 0,25% of rate (Optional) * 1000 : 1 operable flow range * Excellent repeatability * Optional Bi-directional measurement * Advanced

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information

Range of Ultrasonic Flowmeters.

Range of Ultrasonic Flowmeters. Range of Ultrasonic Flowmeters www.adeptfluidyne.com Ultrasonic Flowmeter Series 6700 Working Principle The Transit Time Flowmeter utilises two transducers that function as both, ultrasonic transmitters

More information

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters ProSeries by Blue-White Industries, Ind. Ltd. Industries, Ltd. s SNIC-PR s SNIC-PR s S4 Transit Time Ultrasonic Flowmeter ½ thru 2 diameter Pipe Sizes Inline spool piece Advanced communications Data logging

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Features The T-MAG BTU meter is the latest addition to the SpireMag series for accurate thermal energy measurement. It utilizes a high accuracy electromagnetic

More information

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS HIGH TEMPERATURE SENSORS AS STANDARD FOR PERMANENT INSTALLATION ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS The Ultraflo 2000 is a Transit Time ultrasonic

More information

Octave Water Meter Installation Manual

Octave Water Meter Installation Manual Octave Water Meter Installation Manual 1.0 Notes For proper flow measurements, the OCTAVE s measuring tube should be completely full at all times. Non-wetted sensors show loss of signal. Though this will

More information

ML255 ELECTROMAGNETIC FLOW METER CONVERTER

ML255 ELECTROMAGNETIC FLOW METER CONVERTER ML255 ELECTROMAGNETIC FLOW METER CONVERTER Installation, Operation and Maintenance Manual 30122-46, Rev. 1.2 May 31, 2018 Important Information: Converter Model Number: Converter Serial Number: Meter Serial

More information

Time Delta S Fixed Transit-Time Flow Meter System

Time Delta S Fixed Transit-Time Flow Meter System Fixed Transit-Time Flow Meter System Key Features Dynamic flow correction Simple configuration Digital outputs Enhanced anti-bubble measurement technology (ABM) Rugged and reliable Maintenance free The

More information

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE TABLE OF CONTENTS General Information...4 Warranty...4 Included Items...4 Operation...5

More information

Installation and Operation Instructions DLP Series

Installation and Operation Instructions DLP Series Installation and Operation Instructions DLP Series PRECAUTIONS Figure 1: DLP Dimensions and Hardware REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT WIRING WITH THE POWER APPLIED. DO NOT ALLOW

More information

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008 Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com GTFM IV Gas Turbine Flow Monitor Operation / Installation

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)

More information

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations. Signet 50 High Performance Flow Sensor English *3-50.090* 3-50.090 C 05/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines.. Do not exceed maximum temperature/pressure specifi cations.

More information

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for

More information

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal

More information

2100 Turbine Flow Sensor

2100 Turbine Flow Sensor 200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3

More information

Signet Temperature Transmitter

Signet Temperature Transmitter Signet 80 Temperature English 80.090 80.090 Rev. G /0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS -series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS -SERIES MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS 101 104 The Leader in Flow Meter Value Table of Contents General Information General Information,

More information

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

TEK-F LUX 1400A. Electromagnetic Flowmeter.  Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch. -SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS -Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 3 inch 2 inch 1 inch 9001:2008 ISO CERTIFIED COMPANY GENERAL INFORMATION and FEATURES GENERAL INFORMATION The -Series

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

Vortex Plate. Model VP General Specification. Product Features

Vortex Plate. Model VP General Specification. Product Features Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Heavy Duty & Maintenance Free Design C&C Machined from one piece of solid stainless steel Absolutely NO o-rings or seals

More information

Vortex In Line Flow Meter

Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase to each other, resulting

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

Insertion magnetic inductive flowmeter

Insertion magnetic inductive flowmeter Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041

More information

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations. +GF+ SIGNET 0 High Performance Flow Sensor (English) -0.090- F-/99 English SAFETY INSTRUCTIONS. Do not remove from pressurized lines.. Do not exceed maximum temperature/pressure specifications.. Do not

More information

Model FVP General Specification. Flanged Vortex Plate. Product Features

Model FVP General Specification. Flanged Vortex Plate. Product Features Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from

More information

Hydro-Flow Model 2300 Installation and Operation Guide B

Hydro-Flow Model 2300 Installation and Operation Guide B Hydro-Flow Model 2300 Installation and Operation Guide 5700508-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Electrical Connections.. 7 Mechanical and Electrical

More information

Hot Tap Insertion Vortex

Hot Tap Insertion Vortex Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design

More information

Magnetic Inductive Flowmeter EP / UMF2 (B)

Magnetic Inductive Flowmeter EP / UMF2 (B) Magnetic Inductive Flowmeter EP / UMF2 (B) High accuracy 0.3 % of reading No maintenance required no pressure drop different lining materials different electrode materials inexpensive earthing electrode

More information

Options guide. Electromagnetic flowmeters. M9xx

Options guide. Electromagnetic flowmeters. M9xx Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR MB-3688 120A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR User Manual Warning and Precautions MB-3688 is built with corrosion resistant material and the main electronic assembly is well sealed inside

More information

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Low Pressure Sensor. Overview. Specifications. Installation and Operation Overview The Low Pressure Sensor with display measures building pressure, air velocities and volumes. The heart of the unit is a micro-machined silicon pressure sensor. The unit includes a static pressure

More information

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Electromagnetic flowmeter. Descriptions. Specifications

Electromagnetic flowmeter. Descriptions. Specifications Descriptions The EFM Series is the most economical flanged electromagnetic flowmeter on the market. It is used in 3 to 12 pipe in HVAC, municipal or industrial water, wastewater, pump stations and packaged

More information

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO Digital Paddlewheel Flow meter Operating Manual Blue-White Industries, Ltd. Page 2 TABLE OF CONTENTS 1...Introduction...2 2...Features...3 3...Model number matrix...3 4...Specifications...4 4.1..Temperature

More information

Propeller Meters. Flow measurement solutions for water and wastewater

Propeller Meters. Flow measurement solutions for water and wastewater Propeller Meters Propeller Meters Flow measurement solutions for water and wastewater Perfect flow measurement solutions Water Specialties Propeller Meters are designed and manufactured with precise techniques

More information

Signet 2551 Magmeter Flow Sensor

Signet 2551 Magmeter Flow Sensor Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No

More information

Vortex In Line Flow Meter

Vortex In Line Flow Meter Vortex In Line Flow Meter Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, 0 degrees out of phase

More information

Model 282L Single Point Insertion Electromagnetic Flow Meter 1 and 2 Sensors

Model 282L Single Point Insertion Electromagnetic Flow Meter 1 and 2 Sensors Model 282L Single Point Insertion Electromagnetic Flow Meter 1 and 2 Sensors Installation, Operation and Maintenance Manual 24511-13, Rev. 1.7 August 18, 2017 Contents 1.0 SAFETY SYMBOLS AND WARNINGS...1

More information

VORTEX IN-LINE FLOW METERS

VORTEX IN-LINE FLOW METERS VORTEX IN-LINE FLOW METERS Principles of Operation Vortices are created when a fluid passes around a bluff body as shown below. Vortices are alternately shed on each side of the body, degrees out of phase

More information

CENTRIFLOW METER and ELECTRONICS WIRING and INSTALLATION MANUAL REV 01/16 ORIGINAL LANGUAGE Copyright 2016 Eastern Instrument Laboratories, Inc. All Rights Reserved. TABLE OF CONTENTS SAFETY Safe Operation...

More information

ProcessAutomatic EZ-Mag

ProcessAutomatic EZ-Mag ProcessAutomatic EZ-Mag THE EZ-CHOICE Robust Design: The highly robust and compact EZ-Mag is designed to be able to cope with tough environments. Whether installed in-house or on a vehicle, you can be

More information

USERS MANUAL MCD REMOTE OPERATOR

USERS MANUAL MCD REMOTE OPERATOR USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3

More information

SeaMetrics Flow Meters and Flow Computers

SeaMetrics Flow Meters and Flow Computers Distributed Products Fact Sheet and Flow Computers WTP-PVC body turbine flow meter WT-S Stainless steel body turbine flow meter TX115/215 Hottap insertion turbine flow meter FT420 Looppowered flow computer

More information

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus OVERVIEW The MagneW Neo+ is a high performance two wired electromagnetic flowmeter based on field proven

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability

More information

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value. E X S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s EX Series Electromagnetic FLOW SENSOR instructions EX EX The Leader in Flow Meter Value. Table of Contents General

More information

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE Speed Sensor ã Read and understand equipment operators manual before operating or performing maintenance. Failure to do so could result in serious injury or death. Safety Information Failure to follow

More information

Model DFX Doppler ultrasonic flow meter

Model DFX Doppler ultrasonic flow meter Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Model DFX Doppler ultrasonic flow meter Features Badger

More information

LTX RF LEVEL SENSOR. Instruction Manual

LTX RF LEVEL SENSOR. Instruction Manual LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004

More information

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

Model 5000 Vortex Meter

Model 5000 Vortex Meter Model 5000 Vortex Meter Installation and Instruction Manual Table of Contents General Information... 1 1-1 General... 1 1-2 Principles of Operation... 1 1-3 Sensor Operation... 1 1-4 Calibration Factor...

More information

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter The 10D1477 electrodeless ceramic lined wafer sensors and 50XM1000 transmitters are pulsed DC magnetic flowmeters. These

More information

Model TUR-200D Turbine Flowmeter

Model TUR-200D Turbine Flowmeter General Specifications Model TUR-200D Turbine Flowmeter Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil.

More information