Product Summary. Flow Meters. Hydraulic Diagnostic Products

Size: px
Start display at page:

Download "Product Summary. Flow Meters. Hydraulic Diagnostic Products"

Transcription

1 Product Summary Flow Meters TM Hydraulic Diagnostic Products RACINE FEDERATED INC. ISO 91 : FILE N. A6856

2 Variable Area Flow Meters Basic In-line Flow Meters Hedland offers a complete line of over 15, variable area flow meters to measure oil, phosphate esters, water and water-based fluids, as well as air and other compressed gases. In addition to the basic in-line model, these variable area flow meters are available in high temperature models and test kits with pressure gauge. Rugged, durable construction featuring aluminum, brass and stainless steel bodies Most models available in sizes from 1 /4" to 3" Accuracy of ±2% of full scale Temperatures to 24 F (116 C); 4 F (4 C) for high temperature models Pressures up to 6 psi (414 bar) Operates in any position No flow straighteners or special piping required 36 rotatable scales Custom scales available Flow-Alert Flow Switches The Flow-Alert flow switches provide both visual flow indication and the capability to signal alarms, open or close circuits, trigger warning lights and buzzers, and shut down pumps or other equipment. Micro switch (latching) or reed switch (proximity) models available Choice of one or two switches per meter Available in meter sizes from 1 /4" to 1 1 /2" Accuracy of ±2% of full scale MR Flow Transmitters The MR flow transmitters feature non-contact sensor electronics and are designed to operate as part of a totally integrated electronic process control /data acquisition system. Digital flow rate and total flow indication In-field compensation for application specific fluid parameters eliminates the need for custom scales Provides 4- ma, -1 Vdc or -5 Vdc analog output CE compliant EZ-View In-line Flow Meters The EZ-View product line is a reliable, trouble-free flow rate indicator for low pressure applications. Constructed of high-impact polysulfone plastic, these meters provide a low cost, rugged flow measurement solution for both liquid and air/gas applications. End fittings in brass, 33 stainless steel or PVC Available in sizes from 1 /2" to 2" Temperatures to 25 F (121 C) Pressures up to 325 psi (22.4 bar) Accuracy of ±5% of full scale Flow-Alert TM models available 2 TEL hedland.com

3 Flo-Check USB Hydraulic System Analyzer Flow accuracy ±1% of 32 cst Field selectable US or metric readings High and low set point alarms for flow, pressure and temperature Captures pressure spikes up to 1, PSI (.2 milliseconds duration) Exports saved data to Microsoft Excel and other spreadsheet programs USB powered Easy to use, plug and play Calculates hydraulic power Select continuous monitoring or capture data manually Logs up to 12 hours Records alarm history The Flo-Check Hydraulic System Analyzer can be used as a stationary or portable tester for both industrial and mobile hydraulic system diagnostics, and analysis of the prognostic health of a hydraulic system. It features flow, pressure and temperature sensors that are monitored by a data acquisition module. This module records the operating parameters of the system and transfers them to the user s laptop via the USB port. The custom software utility is a Windows -based application which is compatible with Windows Vista, Windows XP and Windows. This intuitive software configures the displayed information into user-selected engineering units and provides real-time graphics with instantaneous readings and trends for all three measurement parameters. The software also permits the data to be saved for export into a spreadsheet program. The Hydraulic System Analyzer is powered through the USB port of a PC, making it easy to set up and ideal for portable applications. Interfaced to the PC application, the Hydraulic Analyzer offers a straightforward method of monitoring system parameters complete with data acquisition. SPECIFICATIONS Performance Flow: Accuracy ±1% of 32 cst Repeatability ±.2% Pressure: Accuracy <±.5% BFSL Stability <±.25% of full scale Zero Offset <±2% of full scale TC Zero and TC Span <±1.5% of full scale Response Time.2 milliseconds Temperature: Calibration Error (25 C) ±1 C Absolute Error (over full range of sensor, to 15 C) Without Calibration ±3 C With Calibration ±1.6 C Nonlinearity ±.4 C Repeatability ±.1 C Data Acquisition: Sample Rate 1 khz PC Screen Update/Record Rate Flow 1 second (average 1K samples) Temperature 1 second (average 1K samples) Pressure 1 second (min, max, average 1K samples) Power USB Power: +5 VDC (supplied through USB port of a PC) USB Voltage Tolerance: +4.6 VDC min, VDC max Current: 1 ma, typ Environmental Pressure Rating: 6 PSI (414 Bar) maximum with a 3:1 safety factor; capable of 1, PSI transients Operating Pressure: <6 PSI (414 Bar, 41.4 MPa, 4 kg/cm²); capable of 1, PSI transients Internal Valve By-pass: 75 PSI P Pressure Drop: See P charts on page 14 Fluid Temperature: -4 to +3 F (-4 to +15 C) Ambient Temperature: +32 to +185 F ( to +85 C) Storage Temperature: -4 to +185 F (-4 to +85 C) Humidity: -9%, non-condensing Material Housing: Turbine Rotor: Rotor Supports: Seals: Ball Bearings: Hub Cones: Temperature Probe: Valve: Spool/Sleeve: Magnetic Pick-up: Body Nut Electronic Case: Ports: 613-T351 Aluminum; anodized T416 Stainless steel Viton standard; EPR optional 44C Stainless steel 12L14 Steel body with 33 SS seat 12L14 Steel 12L14 Steel; electroless nickel plate 12L14 Steel; electroless nickel plate Cold rolled steel; black zinc plate with clear seal SAE Straight thread O-ring boss, female, J1926/1; ISO1179 (BSPP) Windows, Vista and Excel are registered trademarks of Microsoft Corp. Viton is a registered trademark of DuPont Dow Elastomers. 4 Tel MEASURE SYSTEM PERFORMANCE

4 Flo-Check USB Hydraulic System Analyzer SOFTWARE The Flo-tech Analyzer software provides a real-time graphical and digital interface for monitoring and/or recording pressure, temperature and flow rate parameters from the Hydraulic Analyzer. In addition to the graphical and digital displays, the main screen also consists of a menu bar, buttons with common functions and alarm indicators. The software offers the following options: View real time pressure, temperature, flow rate and power measurements Record all measurements to a file Choice of recording all measurement points or capturing points manually Selection of all measurement units, US or metric Ability to adjust display of graph data High/Low alarm indicators set by the operator All measurements taken can be saved once per second to a comma separated value (.csv) file for export into a spreadsheet program. For example, recording for 2 minutes would yield 1 points of data. Even though data points are only recorded once per second, pressure spikes and dips are captured by recording the maximum or minimum pressure during each measurement period. Therefore, the precise shape of the pressure spike is not recorded but its amplitude and the time it occurred are both recorded. Measurement (over a 1 second time period) Color Indication Graphs The graph on the main screen contains more than 6 points of data. Previous data points are saved in memory and can be viewed at any time. Adjustments can be made to optimize data that is displayed by hiding individual graph plots, adjusting the scale of each plot or adding horizontal gridlines to the graph. Alarms There are three sets of High/Low alarm indicators on the main screen which monitor pressure, temperature and flow rate. Alarm indicators flash if the current system measurements exceed the alarm limits set by the operator and continue to flash when the current system measurements return to normal to alert the operator that an alarm condition occurred. Alarms must be reset manually to acknowledge the alarm condition. ORDERING INFORMATION ¹ NOMINAL PORT SIZE FLOW RANGE F716 SAE GPM F7161 SAE GPM F7162 G LPM F7163 G 1-1/ LPM File View Options Tools About ¹ Each Flo-Check Hydraulic System Analyzer includes a 16.4 ft. (5 M) USB, A male to B male (IP 68) connection cable, CD-Rom of the software utility, and complete operating instructions packaged in a protective carrying case. Pressure Alarms Temp Alarms Flow Alarms Horse Power High/Low High/Low High/Low PSI F GPM HP View History Pressure Avg PressureMin PressureMax Temp Flow 5. PSI 3. F. GPM 45. PSI 27. F 18. GPM 4. PSI 24. F 16. GPM 35. PSI 21. F 14. GPM 3. PSI 18. F 1. GPM 25. PSI 15. F 1. GPM. PSI 1. F 8. GPM 15. PSI 9. F 6. GPM 1. PSI 6. F 4. GPM 5. PSI 3. F. GPM PSI. F. GPM 99.s 1.s 11.s 1.s 13.s 14.s Elapsed Time=:17:28 Alarm Indication Digital Indication Log Interval 4 Hours Minutes Graphical Display Record to File Average Pressure Green Minimum Pressure Dark Green Maximum Pressure Dark Green Average Temperature Blue Average Flow Rate Yellow Average Power Orange ACCESSORIES DESCRIPTION DESCRIPTION F119 5-Point Calibration Certificate ² F Pressure Relief Disc, 75 PSI (1 per Tester) F111 1-Point Calibration Certificate ² ² Certificates are traceable to NIST, ISO 91. Run Clear Graph STOP Record Stop Reset Alarms Test Period Seconds 144 TRACEABLE TO NIST STANDARDS Fax

5 PFM6 Digital Portable Hydraulic Tester Five flow ranges Large 3-1/2 digit LCD for flow and temperature Helical tube pressure gauge One toggle switch to control power and select flow and temperature Loading valve with fingertip control of pressure Platinum resistance temperature sensor Pressure surge protection Turbine flow sensor provides fast response Available with SAE or BSPP ports Pressures up to 6 PSI (414 Bar) Temperatures up to 3 F (15 C) Flow accuracy ±1% of full scale Repeatability ±.2% The PFM6 Series is a compact, lightweight portable tester designed for fast diagnostic troubleshooting of all types of mobile or stationary hydraulic systems and components. These self-contained testers feature laboratory accuracy and provide flow, pressure and temperature measurements simultaneously from one point. Simple operation includes a toggle switch to display either flow or temperature readings and a loading valve that operates with fingertip control. The dual scale helical tube pressure gauge offers pulsation dampening and high overpressure capacity. For safe operation, all testers include pressure surge protection. SPECIFICATIONS Performance Flow Accuracy: ±1% of full scale Repeatability: ±.2% Turbine Response: ms Temperature: Fluid -4 to +3 F (- to +15 C) Ambient -4 to +131 F (- to +55 C) Flow Readout: Linearity and zero shift ±1 digit Operating Pressure: up to 6 PSI (414 Bar, 41.4 MPa, 4 kg/cm 2 ) Pressure Drop: See P charts on page 14 Readout Accuracy: ±1 digit Material Housing: Turbine Rotor: Ball Bearings: Rotor Shaft: Rotor Supports: PFM6-15/3 PFM6-6/85/ Hub Cones: Valve Body: PFM6-15/3 PFM6-6/85/ Valve Stem: Poppet: Sleeve: PFM6- only Temperature Probe: Pick-up: Body Nut Seals: Carrying Handle: Electronic Case & Cover: Battery: Ports: 613-T651 Aluminum; anodized T416 Stainless steel 44C Stainless steel CA36 Brass Cold rolled steel; zinc plate, dichromate finish 12L14 Steel; zinc plate, dichromate finish 12L14 Steel; hardened D.O.M. steel tube Magnetic 12L14 Steel; electroless nickel plate 12L14 Steel; electroless nickel plate Buna N standard; Viton and EPR optional Cast aluminum; anodized Cold rolled steel; zinc plate with clear seal, epoxy black paint 4 AA size alkaline, ~ 5 hours of service SAE Straight thread O-ring boss, female J1926/1; ISO1179 (BSPP) Viton is a registered trademark of DuPont Dow Elastomers. 6 Tel HYDRAULIC SYSTEM DIAGNOSTIC TOOLS

6 PFM6 Digital Portable Hydraulic Tester DIMENSIONS A LENGTH B DEPTH C HEIGHT WEIGHT LBS (KG) PFM (287) 3.5 (89) 9.8 (249) (6.3) PFM (287) 3.5 (89) 9.8 (249) (6.3) PFM (292) 3.5 (89) 9.8 (249) 16.5 (7.5) PFM (292) 3.5 (89) 9.8 (249) 16.5 (7.5) PFM (311) 4. (11) 1.3 (262). (9.1) ORDERING INFORMATION NOMINAL PORT SIZE FLOW RANGE PFM6-15 SAE GPM F58 PFM6-3 SAE GPM F579 PFM6-6 SAE GPM F578 PFM6-85 SAE GPM F577 PFM6- SAE GPM F576 PFM6-15 G 3/ LPM F511 PFM6-3 G 3/ LPM F5111 PFM6-6 G LPM F5112 PFM6-85 G LPM F5113 PFM6- G 1-1/ LPM F5114 STD or CE Leave blank for standard model or CE for CE option PRESSURE GAUGE UNITS OF MEASURE PSI BAR MPA KG/CM2 Examples: F576-PSI = PFM6- SAE 24 ports GPM flow range Standard model PSI pressure units F5111CE-BAR = PFM6-3 G 3/4 ports LPM flow range CE certified Bar pressure units ACCESSORIES DESCRIPTION F Carrying Case PFM6-15 & PFM6-3 F Carrying Case PFM6-6 & PFM6-85 F4934- Carrying Case PFM6- F Pressure Relief Disc, 75 PSI (1 per Tester) All PFM6s F119 5-Point Calibration Certificate ¹ All PFM6s F111 1-Point Calibration Certificate ¹ All PFM6s ¹ Certificates are traceable to NIST, ISO 91. FIVE OR TEN POINT CALIBRATION AVAILABLE Fax

7 PFM6BD Bi-Directional Hydraulic Tester Bi-directional in-line testing capabilities in three flow ranges Large 3-1/2 digit LCD for flow and temperature Helical tube pressure gauge One toggle switch to control power and select flow and temperature Loading valve with fingertip control of pressure Platinum resistance temperature sensor Pressure surge protection with internal pressure relief Turbine flow sensor provides fast response SAE ports Pressures up to 6 PSI (414 Bar) Temperatures up to 3 F (15 C) Flow accuracy ±1% of full scale Repeatability ±.2% The PFM6BD Series includes all the features of the standard PFM6 Series with the added benefit of bi-directional flow measurement and an internal pressure relief system. Designed for fast diagnostic troubleshooting of all types of mobile or stationary hydraulic systems and components, these compact testers offer laboratory accuracy and provide flow, pressure and temperature measurements simultaneously from one point. SPECIFICATIONS Performance Flow Accuracy: Forward ±1% of full scale Reverse ±2% of full scale Repeatability: ±.2% Turbine Response: ms Temperature: Fluid -4 to +3 F (- to +15 C) Ambient -4 to +131 F (- to +55 C) Flow Readout: Linearity and zero shift ±1 digit Operating Pressure: up to 6 PSI (414 Bar, 41.4 MPa, 4 kg/cm 2 ) Pressure Drop: See P charts on page 14 Readout Accuracy: ±1 digit Material Housing: Turbine Rotor: Ball Bearings: Rotor Shaft: Rotor Supports: Hub Cones: Valve Body: Valve Stem: Spool/Sleeve: Temperature Probe: Magnetic Pick-up: Body Nut Seals: Carrying Handle: Electronic Case & Cover: Battery: Ports: 613-T651 Aluminum; anodized T416 Stainless steel 44C Stainless steel 12L14 Steel; zinc plate, dichromate finish 434 Alloy steel; hardened 12L14 Steel; electroless nickel plate 12L14 Steel; electroless nickel plate Buna N standard; Viton and EPR optional Cast aluminum; anodized Cold rolled steel; zinc plate with clear seal, epoxy black paint 4 AA size alkaline, ~ 5 hours of service SAE Straight thread O-ring boss, female J1926/1 Viton is a registered trademark of DuPont Dow Elastomers. 8 Tel RUGGED CONSTRUCTION

8 DIMENSIONS PFM6BD Bi-Directional Hydraulic Tester A LENGTH B DEPTH C HEIGHT WEIGHT LBS (KG) PFM6BD (287) 3.5 (89) 1.1 (256) 16.5 (7.5) PFM6BD (287) 3.5 (89) 1.1 (256) 16.5 (7.5) PFM6BD (3) 4. (11) 1.6 (268) 19.5 (9.) ORDERING INFORMATION NOMINAL PORT SIZE FLOW RANGE STD or CE PRESSURE GAUGE UNITS OF MEASURE PFM6BD-6 SAE GPM ( LPM) F582 Leave blank for PFM6BD-85 SAE GPM ( LPM) F583 standard model or PFM6BD- SAE GPM ( LPM) F584 CE for CE option PSI BAR MPA KG/CM2 Examples: F583-PSI = PFM6BD-85 SAE 16 ports 4-85 GPM ( LPM) Standard model PSI pressure units F582CE- PSI = PFM6BD-6 SAE 16 ports 3-6 GPM ( LPM) CE certified PSI pressure units ACCESSORIES DESCRIPTION F Carrying Case PFM6BD-6 & PFM6BD-85 F4934- Carrying Case PFM6BD- F Pressure Relief Disc, 75 PSI (2 per Tester) All PFM6BDs F119 5-Point Calibration Certificate ¹ All PFM6BDs F111 1-Point Calibration Certificate ¹ All PFM6BDs ¹ Certificates are traceable to NIST, ISO 91. DEPENDABLE CUSTOMER SERVICE Fax

9 PFM8 Digital Hydraulic Tester & Dynamometer Simultaneously Measures Flow, Pressure, Power and Temperature SPECIFICATIONS Performance Flow Accuracy: ±1% of full scale Repeatability: ±.2% Turbine Response: ms Temperature: Fluid -4 to +3 F (- to +15 C) Ambient -4 to +131 F (- to +55 C) Flow Readout: Linearity and zero shift ±1 digit Operating Pressure: up to 6 PSI (414 Bar, 41.4 MPa, 4 kg/cm 2 ) Pressure Drop: See P charts on page 14 Readout Accuracy: ±1 digit Five flow ranges Front panel selectable US or metric readings Dynamometer reads power (HP & kw) directly 3-1/2 digit LCDs for digital display of flow, temperature, pressure and power Large easy-to-use membrane switch Loading valve with fingertip control of pressure Silicon strain gauge pressure sensor Platinum resistance temperature sensor Pressure surge protection Turbine flow sensor provides fast response Pressures up to 6 PSI (414 Bar) Temperatures up to 3 F (15 C) Flow accuracy ±1% of full scale Repeatability ±.2% The all digital PFM8 Series combines a compact, lightweight hydraulic tester and a dynamometer in one unit. Designed for fast diagnostic troubleshooting of all types of hydraulic systems and components, including enginepump combinations. These testers make all flow, temperature, pressure and power measurements from one point. A bonus feature of this series is the capability to switch from US to metric units of measure in the field. Each tester utilizes two digital displays, one for flow and temperature and a second display for pressure and power. Simple operation includes a large format membrane switch for on/off control and selection of units of measure to be displayed. A loading valve with fingertip control and pressure surge protection are standard features. Material Housing: Turbine Rotor: Ball Bearings: Rotor Shaft: Rotor Supports: PFM6-15/3 PFM6-6/85/ Hub Cones: Valve Body: PFM6-15/3 PFM6-6/85/ Valve Stem: Poppet: Sleeve: PFM6- only Temperature Probe: Magnetic Pick-up: Body Nut Seals: Carrying Handle: Electronic Case & Cover: Battery: Ports: 613-T651 Aluminum; anodized T416 Stainless steel 44C Stainless steel CA36 Brass Cold rolled steel; zinc plate, dichromate finish 12L14 Steel; zinc plate, dichromate finish 12L14 Steel; hardened D.O.M. steel tube 12L14 Steel; electroless nickel plate 12L14 Steel; electroless nickel plate Buna N standard; Viton and EPR optional Cast aluminum; anodized Cold rolled steel; zinc plate with clear seal, epoxy black paint AA size alkaline, ~ 5 hours of service SAE Straight thread O-ring boss, female J1926/1 Viton is a registered trademark of DuPont Dow Elastomers. 1 Tel RELIABLE FLOW MEASUREMENT

10 PFM8 Digital Hydraulic Tester & Dynamometer Simultaneously Measures Flow, Pressure, Power and Temperature DIMENSIONS A LENGTH B DEPTH C HEIGHT WEIGHT LBS (KG) PFM (287) 3.5 (89) 9.8 (249) (6.3) PFM (287) 3.5 (89) 9.8 (249) (6.3) PFM (292) 3.5 (89) 9.8 (249) 16.5 (7.5) PFM (292) 3.5 (89) 9.8 (249) 16.5 (7.5) PFM (311) 4. (11) 1.3 (262). (9.1) ORDERING INFORMATION NOMINAL PORT SIZE FLOW RANGE POWER HP (kw) PFM8-15 SAE GPM (4-56 LPM) 52.5 (39) F561 PFM8-3 SAE GPM ( LPM) 15 (78) F558 PFM8-6 SAE GPM ( LPM) 21 (157) F552 PFM8-85 SAE GPM ( LPM) 298 (222) F553 PFM8- SAE GPM ( LPM) 7 (522) F554 Examples: F561 = PFM8-15 SAE 12 ports 1-15 GPM (4-56 LPM) F553 = PFM8-85 SAE 16 ports 4-85 GPM ( LPM) ACCESSORIES DESCRIPTION F Carrying Case PFM8-15 & PFM8-3 F Carrying Case PFM8-6 & PFM8-85 F4934- Carrying Case PFM8- F Pressure Relief Disc, 75 PSI (1 per Tester) All PFM8s F119 5-Point Calibration Certificate ¹ All PFM8s F111 1-Point Calibration Certificate ¹ All PFM8s ¹ Certificates are traceable to NIST, ISO 91. TRACEABLE TO NIST STANDARDS Fax

11 Sensor Array with Load Valve Four flow ranges Analog (4- ma or -5 VDC) or pulse output for flow rate Silicon strain gauge pressure sensor with 4- ma output Platinum resistance temperature sensor with 4- ma output Loading valve with fingertip control of pressure Pressure surge protection Turbine flow sensor provides fast response Pressures up to 6 PSI (414 Bar) Temperatures up to 3 F (15 C) Flow accuracy ±1% of 32 cst Repeatability ±.2% The Sensor Array is used for diagnostic evaluation of hydraulic motors, pumps, valves, hydrostatic drives and cylinders. When performed as part of a routine preventative maintenance program, catastrophic or untimely repairs are minimized. All that is required is to make quick and easy fluid line connections between the sensing array and appropriate locations in the hydraulic circuit. The load valve is used to create a restriction so that a relief valve setting or internal leakage of a valve or hydraulic cylinder can be determined. The efficiency of a hydraulic pump or motor can be similarly established and compared to factory specifications. 12 Tel SPECIFICATIONS Performance Flow Accuracy: ±1% of 32 cst Repeatability: ±.2% Temperature: Fluid -4 to +3 F (- to +15 C) Ambient Operating Pressure: -4 to +131 F (- to +55 C) up to 6 PSI (414 Bar, 41.4 MPa, 4 kg/cm 2 ) Pressure Drop: See P charts on page 14 IFC Signal Converter, Option: F to I F to V Power: Loop powered, 6V 1 to 26 VDC insertion loss max 1 to 3 VDC supply range Inputs: Magnetic Pick-up Magnetic Pick-up Frequency to 35 Hz to 35 Hz Trigger Sensitivity 3 mv p-p 3 mv p-p Frequency Measurement Accuracy ±1% ±1% Analog Output: 4- ma current loop -5 VDC Resolution 1:4 1:4 Temperature Drift 5 ppm / C max 5 ppm / C max Response 1.6 seconds min 1.6 seconds min Environmental: Ambient Temperature -22 to +158 F -22 to +158 F (-3 to +7 C) (-3 to +7 C) Humidity -9%, -9%, non-condensing non-condensing Magnetic Pick-up, Option: Electrical Output Signal Self-generating alternating pulse 1 mv RMS (1 Hz) minimum Pressure Sensor: See page 26 for complete specifications (optional) Temperature Sensor: See page 27 for complete specifications (optional) Material Housing: 613-T651 Aluminum; anodized Turbine Rotor: T416 Stainless steel Ball Bearings: 44C Stainless steel Rotor Shaft: Rotor Supports: PFM6-15/3 CA36 Brass PFM6-85/ Hub Cones: Valve Body: PFM6-15/3 Cold rolled steel; zinc plate, dichromate finish PFM6-85/ 12L14 Steel; zinc plate, dichromate finish Valve Stem: Poppet: 12L14 Steel; hardened Sleeve: PFM6- only D.O.M. steel tube Temperature Probe: Magnetic Pick-up: Body 12L14 Steel; electroless nickel plate Nut 12L14 Steel; electroless nickel plate Seals: Buna N standard; Viton and EPR optional Carrying Handle: Cast aluminum; anodized Ports: SAE Straight thread O-ring boss, female J1926/1; ISO1179 (BSPP) Viton is a registered trademark of DuPont Dow Elastomers. MEASURE SYSTEM PERFORMANCE

12 DIMENSIONS Sensor Array with Load Valve A LENGTH B DEPTH C HEIGHT WEIGHT LBS (KG) F615 / F (287) 3.5 (89) 9.8 (249) (6.3) F6153 / F (287) 3.5 (89) 9.8 (249) (6.3) F6156 / F (292) 3.5 (89) 9.8 (249) 16.5 (7.5) F6159 / F (311) 4. (11) 1.3 (262). (9.1) ORDERING INFORMATION NOMINAL PORT SIZE FLOW RANGE FLOW TRANSDUCER SEALS TEMPERATURE PRESSURE SAE GPM F615 SAE GPM F6153 SAE GPM F6156 SAE GPM F6159 G 3/ LPM F6161 G 3/ LPM F6163 F Frequency (Mag Pick-up) I 4- ma Out (IFC) V -5 VDC Out (IFC) B Buna N V Viton E EPR T with Sensor G G 1/4 (F) Plugged SAE 2 (J514) Plugged 1 1 PSI (69 Bar) Sensor 3 3 PSI (7 Bar) Sensor 5 5 PSI (345 Bar) Sensor 6 6 PSI (414 Bar) Sensor G G 1/4 (F) Plugged 1/4 NPTF (F) Plugged G LPM F6165 G 1-1/ LPM F6167 Examples: F615-I B - T 6 = SAE 12 ports 1-15 GPM flow range 4- ma output Buna N seals Temperature sensor 6 PSI (414 Bar) pressure sensor F6165-F V- G 5 = G 1 ports LPM flow range Frequency output Viton seals G 1/4 (F) plugged temp port 5 PSI (345 Bar) pressure sensor ACCESSORIES DESCRIPTION F Pressure Relief Disc, 75 PSI (1 per Sensor) F119 5-Point Calibration Certificate ¹ F111 1-Point Calibration Certificate ¹ ¹ Certificates are traceable to NIST, ISO 91. All Sensor Arrays For information about Refer to Digital Displays Form No. 549 Pressure Sensors Page 26 Temperature Sensor Page 27 Cables Pages 28 & 29 Viton is a registered trademark of DuPont Dow Elastomers. FIVE OR TEN POINT CALIBRATION AVAILABLE Fax

13 Flow vs Pressure Drop Charts Flo-Check USB, PFM Series and F61 Sensor Arrays 6 PFM6-15, PFM8-15, F615, F PFM6-3, PFM8-3, F6153, F PFM6-6, PFM8-6 1 PFM6-85, PFM8-85, F6156, F PFM6 -, PFM8 -, F6159, F PFM6BD FORWARD REVERSE PFM6BD - 85, F716, F PFM6BD -, F7161, F FORWARD REVERSE FORWARD REVERSE Tel TRACEABLE TO NIST STANDARDS

14 TM Hydraulic Diagnostic Products Flo-Check USB Hydraulic System Analyzer The Flo-Check USB represents the next generation of hydraulic test equipment. The device simultaneously measures flow, pressure, temperature and power within a hydraulic system. This data is displayed and logged through a custom Windows -based software application; data is received from the Analyzer through a standard USB cable (both software and cable are included with the unit). The Flo-Check USB is ideal for testing, troubleshooting and diagnosis in mobile and industrial hydraulic applications, and for setting hydraulic components such as pumps, valves and motors. The unit is bi-directional and includes a low-resistance load valve and internal pressure relief discs. ±1% of full scale accuracy Field selectable US or metric readings High and low set point alarms for flow, pressure, and temperature Captures pressure spikes up to 69 bar (1, psi).2 milliseconds duration Exports saved data to Microsoft Excel and other spreadsheet programs USB powered Easy to use, plug and play Calculates hydraulic power Select continuous monitoring or capture data manually Logs up to 12 hours Records alarm history Flo-tech Portable Hydraulic Testers Flo-tech s compact, self-contained portable hydraulic testers provide fast diagnostic troubleshooting of all types of mobile or stationary hydraulic systems. Models available include the versatile PFM6, the PFM6BD for bi-directional applications and the all digital PFM8 which includes a dynamometer. Flow ranges from 1-15 to GPM (4-56 to LPM) Port sizes from SAE 12 to SAE 24 (G 3 /4 to G 1 1 /2) Accuracy of ±1% of full scale (forward flow) Temperatures to 3 F (15 C) Pressures up to 6 psi (414 bar) Flo-tech Turbine Flow Sensors Flo-tech s turbine flow sensors are available in a variety of configurations for measuring flow, as well as temperature and pressure, of hydraulic fluids or other compatible fluids. Four basic models are available Activa, Ultima, Classic and Quad. Flow ranges from.4-7 to 1-35 GPM ( to LPM) Port sizes from SAE 8 to SAE, (G 1 /4 to G 1 1 /4); SAE to SAE 24, Code 61; and SAE to SAE 32, Code 62 Available with frequency or analog output for flow Optional pressure and temperature analog outputs Accuracy of ±1% of full scale (forward flow) Temperatures to 3 F (15 C) Pressures up to 6 psi (414 bar) Bi-directional flow measurement available (Quad models) Flo-tech Digital Displays/Signal Processors Flo-tech also offers a line of digital panel displays/signal processors to provide a complete flow measurement package. Various models are available that will accept either the 4- ma signal from Flo-tech s Activa Sensor Array or frequency signal input from the Ultima, Classic and Quad turbine flow sensors. Displays rate and/or total AC, DC, battery and loop powered versions Built-in sensor or transmitter power supply Optional analog output, digital communications and setpoint alarms CE compliant hedland.com MAILING ADDRESS P.O. Box 8158 Racine, WI USA SHIPPING ADDRESS 8635 Washington Avenue Racine, WI USA TELEPHONE HEDLAND FAX CHK-FLOW hedlandsales@racinefed.com HEDLAND, EZ-VIEW, and FLO-CHECK are registered trademarks of Racine Federated Inc. Flow-Alert, Flo-tech and Activa are trademarks of Racine Federated Inc. Victaulic is a registered trademark of Victaulic Company. CSA is a registered trademark of Canadian Standards Association. Windows and Excel are registered trademarks of Microsoft Corp. 9 Racine Federated Inc., all rights reserved. Form No /9 Printed in USA Racine Flow Meter Group

Hydraulic Diagnostic Products. Fixed Position and Portable Equipment. Catalog

Hydraulic Diagnostic Products. Fixed Position and Portable Equipment. Catalog Hydraulic Diagnostic Products Fixed Position and Portable Equipment Catalog Table of Contents Portable Hydraulic Testers General Design Features Page 3 Flo-Check USB Hydraulic System Analyzer Page 4-5

More information

PFM6 Digital Portable Hydraulic Tester

PFM6 Digital Portable Hydraulic Tester PFM6 Digital Portable Hydraulic Tester temperature Helical tube pressure gauge One toggle switch to control power and pressure Platinum resistance temperature sensor Pressure surge protection with internal

More information

PFM Portable Hydraulic Testers. PFM6, PFM6BD and PFM8. User Manual. TUR-UM EN-02 (August 2014)

PFM Portable Hydraulic Testers. PFM6, PFM6BD and PFM8. User Manual. TUR-UM EN-02 (August 2014) PFM Portable Hydraulic Testers PFM6, PFM6BD and PFM8 TUR-UM-73-EN-2 () User Manual PFM Portable Hydraulic Testers, PFM6, PFM6BD and PFM8 CONTENTS Introduction.........................................................................iii

More information

Flow-Alert Flow Switches (Micro Switch)

Flow-Alert Flow Switches (Micro Switch) Flow-Alert Flow witches (Micro witch) Automatically signals alarm if flow is too high or too low Automatically opens or closes electrical circuits Triggers warning lights, buzzers and other devices huts

More information

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL With Flow-Alert TM Flow Switch Reed switch and latching models Automatically signals alarm if flow is too high or too low Models available for AC or DC power supply Latching models include Hirschmann type

More information

8000 Series Liquid Flow Meter

8000 Series Liquid Flow Meter PRODUCT DATA SHEET 8000 Series Liquid Flow Meter Advanced microprocessorbased flow measurement technology in a compact, leak-tight package. Flow ranges from 0.02 to 60 GPM / 0.1 to 227 LPM Accuracy of

More information

EZ-View. Flow Meters ISO CERTIFIED 9001

EZ-View. Flow Meters ISO CERTIFIED 9001 EZ-View ISO CERTIFIED 9001 General Design Features OPERATING PRINCIPLE The EZ-View Flow Meter is a variable-area instrument. A precisionmolded, sharp-edged Orifice, located within the Piston Assembly,

More information

8000 Series Liquid Flow Meters

8000 Series Liquid Flow Meters PRODUCT DATA SHEET 8000 Series Liquid Flow Meters Advanced microprocessorbased flow measurement technology in a compact, leak-tight package Flow ranges from 0.2 to 227 LPM / 0.05 to 60 GPM Accuracy of

More information

Flow meters, Flow switches and Flow transmitters

Flow meters, Flow switches and Flow transmitters MAX FLOW SIZES FROM 80 TO 500 GPM (300 TO 1800 LPM) MAX LIQUID PRESSURE 300 PSI (20.69 BAR) LN SERIES MAX LIQUID PRESSURE 1000 PSI (68.97 BAR) LE SERIES Flow meters, Flow switches and Flow transmitters

More information

SAE J1939 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions

SAE J1939 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions SAE J99 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions Milwaukee, WI, USA Tel: + () 769-600 sales-us@webtec.com

More information

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer Datum Electronics has further extended its standard range of torque transducers to cater for higher rotary speeds and an increased number of torque ranges. The 420 Series torque transducers operate with

More information

PFM Portable Hydraulic Testers. PFM6, PFM6BD, and PFM8. Badger Meter. Installation & Operation Manual. 05-TUR-UM EN (September 2012)

PFM Portable Hydraulic Testers. PFM6, PFM6BD, and PFM8. Badger Meter. Installation & Operation Manual. 05-TUR-UM EN (September 2012) PFM Portable Hydraulic Testers PFM6, PFM6BD, and PFM8 Badger Meter 5-TUR-UM-193-EN (September 12) Installation & Operation Manual Page ii September 12 CONTENTS INTRODUCTION 5 PFM6 Digital Hydraulic Tester

More information

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements. BASIC Data Sheet No. B-699 IN-LINE LIQUID FLOW RATE MONITORS CHOICE OF THREE MATERIALS OF CONSTRUCTION Select from aluminum, brass or stainless steel to meet system and liquid requirements. UNRESTRICTED

More information

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP DESCRIPTION The MEMFlo MFTV Metal Bodied Flow Meters with Clear Top are simple, accurate, meters for use in a wide range of industrial liquid and gas

More information

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE General Design Features 9 8 5 6 7 4 3 2 1 10 OPERATING PRINCIPLE The EZ-View Flow Meter is a variable area instrument. A precisionmolded, sharp-edged Orifice 1, located within the Piston Assembly, 2 forms

More information

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device 2SGT Electronic Pressure Instrument Three Separate Functions in a Single Loop-Powered Device Switch Two Independent, Programmable SPST Solid State Relays Program switch open and close values in engineering

More information

G2 Industrial Grade Meters

G2 Industrial Grade Meters G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine

More information

Portable pressure calibrator, Wally Box III Model CPH7600

Portable pressure calibrator, Wally Box III Model CPH7600 Calibration technology Portable pressure calibrator, Wally Box III Model CPH7600 WIKA data sheet CT 17.01 Applications Calibration service companies and service industry Measurement and control laboratories

More information

KEL DIFFERENTIAL PRESSURE FLOWMETERS

KEL DIFFERENTIAL PRESSURE FLOWMETERS KEL DIFFERENTIAL PRESSURE FLOWMETERS Flow Pressure Level Temperature measurement monitoring control Rugged Metal Construction Flow Rate to 2000 GPM Linear Scale For Horizontal or Vertical Pipes Threaded

More information

PRESSURE BENCH OPERATING INSTRUCTIONS

PRESSURE BENCH OPERATING INSTRUCTIONS PRESSURE BENCH OPERATING INSTRUCTIONS Overview: The pressure bench system allows the user to apply a variety of calibrated pressures to a variety of high and low pressure transducers. In addition the system

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

CTR Series. Turbine low meters with conditioned output and built-in loading valve. Up to. Output Options. Features. Hydraulic measurement and control

CTR Series. Turbine low meters with conditioned output and built-in loading valve. Up to. Output Options. Features. Hydraulic measurement and control CTR Series Turbine low meters with conditioned output and built-in loading valve Milwaukee, WI 323, USA Tel: +1 (414) 769-6400 sales-us@webtec.com St. Ives, Cambs. PE27 3LZ, UK Tel: +44 (0) 1480 397 400

More information

Pressure Instrument Testing Equipment

Pressure Instrument Testing Equipment Pressure Instrument Testing Equipment BULLETIN TE-1 A Halliburton Company A Durable, Portable Primary Standard Model 1305D Deadweight Tester The Ashcroft 1305D Deadweight Tester is an affordable, portable

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Page 1 of 5 TI-P197-01 MI Issue 1 UTM10 Series Ultrasonic Transit-time Flowmeters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal

More information

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment CLARK SOLUTIONS 400 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches 1,2 & 3 Switch output, Adjustable Ranges 30 Vac to 6000 PSI, -180 to 650 o F DESCRIPTION The 400 Series is a versatile family

More information

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview Product Description The MediaGauge MG-MD is a multi-functional digital pressure gauge consisting of a media isolated piezoresistive pressure sensing element, signal conditioning circuitry for temperature

More information

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS). PRODUCT APPLICATIONS / APPLICATION QUALIFICATION DIMENSIONAL SPECIFICATIONS MECHANICAL DIMENSIONS: INCHES (mm) DOPPLER ULTRASONIC FLOW METER Carbonated liquids Mining slurry Drilling mud Coal-seam water

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance

More information

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7 Features User Accessible Memory for Test Configuration Management ±0.05% FS System Accuracy EU Throughput Rates of 500 Hz Auto-Negotiating 10/100 BaseT Ethernet with TCP & UDP Protocol Pressure Ranges

More information

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument 7526A Precision Process Calibrator Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument The 7526A Precision Process Calibrator calibrates a wide range of pressure

More information

HUMIDITY / TEMPERATURE TRANSMITTER

HUMIDITY / TEMPERATURE TRANSMITTER HUMIDITY / TEMPERATURE TRANSMITTER SEM161, SEM16 CONFIGURATION USING USB PORT POWERED CONFIGURATOR HUMIDITY, TEMPERATURE, DEW POINT MEASUREMENT INTERCHANGEABLE DIGITAL SENSOR HIGH ACCURACY AND STABILITY

More information

Transmitting Transducer. Gas/Air Velocity Range:

Transmitting Transducer. Gas/Air Velocity Range: RNG Series Insertion-Style Gas Flow Meter The RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flow range. The meters

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER CALIBRATION Every ONICON flow meter is wet calibrated in a flow laboratory against standards that are directly traceable to N.I.S.T. A certificate of calibration

More information

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Electronic Pressure Measurement WIKA Datasheet PSD-10 Applications Hydraulics and pneumatics Filter monitoring Pump control

More information

Flow Measurement Technology Training

Flow Measurement Technology Training Flow Measurement Technology Training Küppers Elektromechanik GmbH TASI Flow Division Küppers Elektromechanik GmbH TASI s Flow Group Territories Küppers Elektromechanik GmbH AW-Lake History AW Company formed

More information

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless

More information

TURBINE FLOW METER SELECTION GUIDE

TURBINE FLOW METER SELECTION GUIDE TURBINE FLOW METER SELECTION GUIDE I. MODEL NUMBERING SYSTEM Format: F(B)-XX YY SERIES F-11 Single Turbine, Insertion Type (1¼" and larger pipes) F-12 Dual Turbine Insertion Type (2½" and larger pipes)

More information

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor! PRESSURE SENSORS PRESSURE PDP3 Series 0-2 32 PDP3 Series 0-10, 0-25 34 PG Gauge Series 36 PW Wet-Wet Series (Cable Version) 38 PW Wet-Wet Series (Conduit Version) 40 PW Series Ordering Guidance 42 Selectable

More information

FIRST FOR PORTABLE PARTICLE COUNTING

FIRST FOR PORTABLE PARTICLE COUNTING FIRST FOR PORTABLE PARTICLE COUNTING FS9V2-RH & FS9V2-RH-HP - particulate and relative humidity monitoring The FS9V2-RH Particle Pal displays live cleanliness readings for particulate (ISO/NAS/SAE) and

More information

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description PIECAL 322 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 322-1 you can check & calibrate all your thermocouple instruments and measure thermocouple

More information

UNIVERSAL Flow Meters

UNIVERSAL Flow Meters MAX FLOW SIZES FROM 500 TO 1500 GPM (2000 TO 5600 LPM) MAX LIQUID PRESSURE 300 PSIG (20.69 BAR) XHF SERIES UNIVERSAL Flow Meters An Extra-Large Vane Style For Liquids NIST Traceable Calibration Certificate

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS LC pressure and temperature compensated flowmeter easy and cost effective installation of the senor no pressure loss caused by the sensor no moving parts, i.e.

More information

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments

Time Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments Time Electronics Calibration, Test and Measurement Portable Process and Pressure Calibration Instruments Calibrators Simulators Sources Pumps Gauges www.timeelectronics.com Loop & Temperature Calibration

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES INLINE VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

TELEDYNE HASTINGS INSTRUMENTS

TELEDYNE HASTINGS INSTRUMENTS TELEDYNE HASTINGS INSTRUMENTS MODELS HFM-D-3 & 305 HFC-D-3 & 307 FEATURES Flows from 0-25 slm (N2 Equivalent) up to 0-2500 slm (N2 Equivalent) Accuracy in Nitrogen (0.2% of Full scale + 0.5% of Reading)

More information

SensoControl Diagnostic Equipment

SensoControl Diagnostic Equipment SensoControl Diagnostic Equipment Together, We Can Measure and Record Critical Data A Wise Investment An ounce of prevention Diagnosing a problem before it occurs should be your primary objective. Whether

More information

A1 Commercial Grade Meters

A1 Commercial Grade Meters A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like

More information

Signet 2551 Magmeter Flow Sensor

Signet 2551 Magmeter Flow Sensor Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No

More information

Model FVP General Specification. Flanged Vortex Plate. Product Features

Model FVP General Specification. Flanged Vortex Plate. Product Features Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from

More information

2100 Turbine Flow Sensor

2100 Turbine Flow Sensor 200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

TECHNICAL SPECIFICATIONS. Measuring Accuracy ±2% of full scale. Repeatability ±0.5% of full scale

TECHNICAL SPECIFICATIONS. Measuring Accuracy ±2% of full scale. Repeatability ±0.5% of full scale TECHNICAL SPECIFICATIONS Measuring Accuracy ±2% of full scale Repeatability ±0.5% of full scale Flow Measuring Range 1/2 porting: 0.5 15 GPM (2 60 LPM) 3/4 1 porting: 1.5 50 GPM (60 200 LPM) Turn Down

More information

VELOCICALC MULTI-FUNCTION VENTILATION METER MODEL 9565

VELOCICALC MULTI-FUNCTION VENTILATION METER MODEL 9565 VELOCICALC MULTI-FUNCTION VENTILATION METER MODEL 9565 The VelociCalc Model 9565 series are portable handheld Multi-Function Ventilation Test Instruments featuring a menu-driven user interface for easy

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS COMMERCIAL GRADE METERS Look for the silver label! Look for the silver label! COMMERCIAL GRADE METERS Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters

More information

Low Profile DC Power Supply with Zero Voltage Soft Switching

Low Profile DC Power Supply with Zero Voltage Soft Switching Sorensen XFR Series Low Profile DC Power Supply with Zero Voltage Soft Switching Analog programming Zero voltage soft switching Constant voltage or constant current operation with automatic crossover and

More information

Model DFX Doppler ultrasonic flow meter

Model DFX Doppler ultrasonic flow meter Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Model DFX Doppler ultrasonic flow meter Features Badger

More information

QUANTUM LX CONTROL PANEL

QUANTUM LX CONTROL PANEL Form E90-020 SPC (APR 2006) File: EQUIPMENT MANUAL - Section 90 Replaces: E90-020 SPC (JUN 2005) Dist: 1, 1a, 1b, 1c, 4a, 4b, 4c QUANTUM LX CONTROL PANEL The most technologically advanced screw compressor

More information

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used

More information

Flow meters, Flow switches and Flow transmitters

Flow meters, Flow switches and Flow transmitters MAX FLOW SIZES FROM 10 TO 160 GPM (60 TO 600 LPM) MAX LIQUID PRESSURE 300 PSI (20.69 BAR) MN SERIES MAX LIQUID PRESSURE 500 PSI (34.48 BAR) MM SERIES MAX LIQUID PRESSURE 2000 PSI (137.93 BAR) MH SERIES

More information

Model HRDT High Resolution Digital Telemetry Rotary Torque Transducer

Model HRDT High Resolution Digital Telemetry Rotary Torque Transducer Model HRDT High Resolution Digital Telemetry Rotary Torque Transducer Capacities from 250 to 10K Nm (2,200 to 88,500 lb-in) Full 18-bit useable resolution (24 bit internal) 2,000 fully processed results

More information

Weatherproof Tubular Slip Ring Assembly

Weatherproof Tubular Slip Ring Assembly Weatherproof Tubular Slip Ring Assembly Model B8-4.3W 8 circuit weatherproof slip ring Compact design Mounts on shafts up to 4.3 [109.2 mm] in diameter Permanently lubricated bearings Rugged stainless

More information

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics Model 322 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 322 you can check & calibrate all your thermocouple instruments and measure thermocouple

More information

Simple to use portable hydraulic testers...

Simple to use portable hydraulic testers... Simple to use portable hydraulic testers... An easy to use range of portable testers for field and workshop testing of hydraulic systems. The Webster range of testers have been designed to meet the needs

More information

JUMO dtrans p20 DELTA

JUMO dtrans p20 DELTA Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision

More information

M Series. Feature rich flow meter and switch with in-line. flow

M Series. Feature rich flow meter and switch with in-line. flow Features Wide flow rangeability Outstanding accuracy State-of-the-art electronics - high reliability 4-20 ma, 0-10 VDC, or pulse output Visual indication Adjustable flow switch - built in Small footprint

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology zfa01 Global Filtration Technology 157 Why on-site fluid analysis? Certification of fluid cleanliness levels Immediate and accurate results Early warning tool to help prevent catastrophic failures in critical

More information

Before first operating the equipment read the whole of these instructions. Safety may be impaired if they are not followed.

Before first operating the equipment read the whole of these instructions. Safety may be impaired if they are not followed. CT/LT Turbine Flow Meters User Manual CT/LT Durchflussturbinen Bedienungsanleitung Manuel d utilisation des débitmètres à turbine CT/LT Manual de usuario para los caudalímetros de turbina serie CT/LT www.webtec.com

More information

PIECAL 520B & 521B Thermocouple Source Operating Instructions

PIECAL 520B & 521B Thermocouple Source Operating Instructions PIECAL 520B & 521B Thermocouple Source Operating Instructions (Shown without optional boot) Product Description Easy to use With the PIECAL 520B/521B you can check & calibrate all your thermocouple instruments.

More information

VHS... Screw Flow Meter

VHS... Screw Flow Meter Member of the Group VHS... Screw Flow Meter The normal transmitter with block plug already has a push pull output to serve all NPN or PNP Inputs. It supplies a square wave signal. Those transducers are

More information

Flow meters, Flow switches and Flow transmitters

Flow meters, Flow switches and Flow transmitters MAX FLOW SIZES FROM 0.5 TO 20 GPM (2 TO 75 LPM) MAX LIQUID PRESSURE 300 PSI (20.69 BAR) SN SERIES MAX LIQUID PRESSURE 500 PSI (34.48 BAR) SM SERIES MAX LIQUID PRESSURE 2000 PSI (137.93 BAR) SH SERIES Flow

More information

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters AST44LP Intrinsically Safe Low Transducers / Transmitters Class I Division 1 Groups C, D IS with Approved Barrier OVERVIEW The AST44LP is a stainless steel pressure transducer with a wide variety of options.

More information

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4 18 NPT - 24VDC ma - NPN - M12 Characteristics Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC - 4..20 ma - NPN - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short

More information

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12 Characteristics Pressure sensors XMLR 400bar - G 1/4-24VDC - 0..10 V - NPN - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short name

More information

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Pressure measurements can easily be taken any time, anywhere. RoHS Compact and lightweight Portable type with a lightweight of only about 00 g (unit 50 g, battery 50 g) can also be held

More information

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PRESSURE TRANSDUCERS. Specifications. Individual Specifications 00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need

More information

Model 422 Automated Thermocouple Calibrator Operating Instructions. Product Description

Model 422 Automated Thermocouple Calibrator Operating Instructions. Product Description Model 422 Automated Thermocouple Calibrator Operating Instructions Product Description Easy to use With the PIECAL 422 you can check & calibrate all your thermocouple instruments and measure thermocouple

More information

MS4525 SPECIFICATIONS

MS4525 SPECIFICATIONS SPECIFICATIONS PCB Mounted Pressure Transducers Amplified Ratiometric Analog Output Differential, Gage, Absolute, Compound, & Vacuum Temperature Compensated 3.3 or 5.0 Vdc Supply Voltage The MS4525 is

More information

Pressure sensor for liquid and gaseous media QBE620-P...

Pressure sensor for liquid and gaseous media QBE620-P... 1 904 Pressure sensor for liquid and gaseous media QBE620-P... Pressure sensor for the measurement of positive pressure in HVAC applications. Piezo-resistive system of measurement DC 0...10 V output signal

More information

PROHOOD AIR CAPTURE HOOD MODEL PH731

PROHOOD AIR CAPTURE HOOD MODEL PH731 PROHOOD AIR CAPTURE HOOD MODEL PH731 The PH731 ProHood Capture Hood is a multipurpose electronic air balancing instrument primarily used for efficiently taking direct air volume readings at diffusers and

More information

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port.

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port. Control Valves & Valve Accessories PNEUMADYNE, INC. Catalog 00 Phone 76-559-077 Fax 76-559-0547 Features Single stem design Compact size Four input options Numerous porting configurations Fully ported

More information

Continental Hydraulics Installation Manual CEM-AA-A

Continental Hydraulics Installation Manual CEM-AA-A Continental Hydraulics Installation Manual CEM-AA-A Description: This power amplifier drives either single or dual solenoid proportional valve coils up to 2.6A. It is suitable to control current to proportional

More information

Differential Pressure and Flow meters Accessories for the Media Series

Differential Pressure and Flow meters Accessories for the Media Series Differential Pressure and Flow meters Accessories for the Media Series 7 8 9 10 11 6 12 Media 5 Media 6 Media 05 1 5 2 4 Media 4 3 Selection and application These accessories upgrade the devices of the

More information

A1 Commercial Grade Meters

A1 Commercial Grade Meters A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like

More information

Vortex Plate. Model VP General Specification. Product Features

Vortex Plate. Model VP General Specification. Product Features Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Heavy Duty & Maintenance Free Design C&C Machined from one piece of solid stainless steel Absolutely NO o-rings or seals

More information

Types E2 and D2. Types Q and L. Including products with: Digital Precision Pressure Gauges

Types E2 and D2. Types Q and L. Including products with: Digital Precision Pressure Gauges JJ Types E-Ex and D-Ex JJ Types E2 and D2 JJ Type J JJ Type P JJ Types Q and L Including products with: Digital Precision Pressure Gauges DS_Digital_Precision_Pressure_gauges 01/2016 Digital precision

More information

Thermo Scientific Gilmont

Thermo Scientific Gilmont Direct Reading Laboratory Flowmeters Instruments Wide selection of flow ranges measure air from 0.02 ml/min to 137 LPM or water from 0.0002 ml/min to 4.1 LPM Excellent chemical compatibility with glass

More information

PX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid

PX409 Series. mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to psid Micro-Machined Silicon Transducers wet/dry differential mv/v, 0 to 5 or 0 to 10 Vdc, or 4 to 20 ma Outputs Uni-Directional Ranges 0-10 inh2o to 0-1000 psid PX409 Series Standard U 5-Point NIST Traceable

More information

Variable Area Flow Meters and Flow Switches. Easy-to-Use and Reliable Flow Measurement.

Variable Area Flow Meters and Flow Switches. Easy-to-Use and Reliable Flow Measurement. Variable Area and Flow Switches Easy-to-Use and Reliable Flow Measurement. Variable Area and Flow Switches The Hedland product line features over 15,000 inline, variable area flow meters to measure oil,

More information

INSTRUMENTATION & CONTROL

INSTRUMENTATION & CONTROL Irrigation Controller.................... 172 Window Controller.................... 174 Water Meter Controller.................. 176 Digital Level Switch.................... 177 Filtration Controller Set..................

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

SATRON VTe pressure transmitter

SATRON VTe pressure transmitter SATRON VTe pressure transmitter belongs to the series V-transmitters which will have both analog and smart properties. SATRON VTe is used for 0-4 kpa...0-00 MPa ranges. The transmitter communicates in

More information

F-2600 SERIES INLINE VORTEX FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER F-2600 SERIES ININE VORTEX FOW METER APPICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260 C)

More information

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Mid-West Instrument. Series 700 Wet/Wet Installation and Operating Instructions. Differential Pressure Transmitter Mid-West Instrument IM_700/A Series 700 "Wet/Wet" Installation and Operating Instructions Differential Pressure Transmitter 6500 Dobry Dr. Sterling Heights, MI USA Toll Free: 800-648-5778 Ph 586-254-6500

More information

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM Honeywell Zephyr TM Analog Airflow Sensors HAF Series High Accuracy ±50 SCCM to ±750 SCCM Honeywell Zephyr TM Analog Airflow Sensors HAF Series - High Accuracy Honeywell Zephyr HAF Series sensors provide

More information

Flow meters, Flow switches and Flow transmitters

Flow meters, Flow switches and Flow transmitters MAX FLOW SIZES FROM 10 TO 160 GPM (60 TO 600 LPM) MAX LIQUID PRESSURE 300 PSI (20.69 BAR) MN SERIES MAX LIQUID PRESSURE 500 PSI (34.48 BAR) MM SERIES MAX LIQUID PRESSURE 2000 PSI (137.93 BAR) MH SERIES

More information

SPG-DIGI. Operating Instruction. Please read carefully before use!

SPG-DIGI. Operating Instruction. Please read carefully before use! WALTER STAUFFENBERG GMBH & CO.KG Im Ehrenfeld 4 D-58791 Werdohl Postfach 1745 D-58777 Werdohl Germany Tel.: +49 (0) 2392 / 916-0 Fax: +49 (0) 2392 / 2505 E-Mail: sales@stauff.com Internet: www.stauff.com

More information