INSTRUCTION MANUAL HEAVY DUTY TYPE PNEUMATIC CYLINDER 10A-2V2 (K2) SERIES
|
|
- Nathan Mitchell
- 5 years ago
- Views:
Transcription
1 No: 08-T064 INSTRUCTION MANUAL HEAVY DUTY TYPE PNEUMATIC CYLINDER 10A-2V2 (K2) SERIES <<For safe use of product>> Wrong operation of the product may result in unavailability of exhibition of full performance of the product or lead to a serious accident. To prevent occurrence of an accident, be sure to read the Instruction Manual of the product carefully to completely understand the contents given therein before operating the product. Those described as precautions are items to which your careful attention has to be paid. Operators or products may be injured or damaged, unless these precautions are strictly observed. Accordingly, be sure to operate the product in strict conformance with the instructions given therein. If you find any unclear point, contact us. TAIYO, LTD Kitaeguchi, Higashiyodogawa-ku Osaka JAPAN URL:
2 No: 08-T064 LIST OF CONTENT 1. FOR SAFE USE PRES FOR OPERATION OF PNEUMATIC CYLINDERS... 4 PRES ON RELATED LEGISLATION... 4 PRES ON RELATED DESIGN... 4 PRES ON SELECTION... 4 PRES ON AIR PRESSURE SOURCE... 5 PRES ON OPERATING ENVIRONMENT... 5 PRES ON INSTALLATION... 6 PRES ON PIPING... 6 PRES ON LUBRICATION... 7 PRES ON TRIAL OPERATION AND ADJUSTMENT... 7 PRES ON MAINTENANCE AND INSPECTION... 7 PRES ON STORAGE... 8 PRES ON SCRAPING INSTRUCTIONS FOR USE... 9 ENVIRONMENTAL CONDITIONS... 9 MOUNTING... 9 MOUNTING OF ROD END IN THE CASE OF FIXED TYPE MOUNTING OF CYLINDER...10 OPERATION PIPING OTHER NOTES MAINTENANCE (MAINTENANCE AND INSPECTION) PRE FOR OPERATION OF SWITCHES PRES ON DESIGN AND SELECTION PRES ON MOUNTING AND ADJUSTMENT PRES ON WIRING PRES ON OPERATING ENVIRONMENT PRES ON MAINTENANCE HOW TO ADJUST THE SWITCH DETECTING POSITION PRE FOR OPERATION OF VALVES PRES ON DESIGN AND SELECTION PRES ON AIR PRESSURE SOURCE PRES ON INSTALLATION PRES ON LUBRICATION PRES ON TRIAL OPERATION PRES ON MAINTENANCE... 21
3 1. FOR SAFE USE Cautionary descriptions given here are for correct use of the products and for prevention of hazard on you and other people in vicinity and damage with equipment. These descriptions are divided into three items of DANGER, and depending on the severity of hazard or damage and level of imminence. All bear important descriptions pertaining to safety. Strictly observe the instructions in addition to those of ISO4414*1), JISB8370*2) and other safety rules. DANGER : : : Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which could result in death or serious injury, if the equipment is operated wrongly. Indicates a potentially hazardous situation which may result in injury and machine damage, if the equipment is operated wrongly. *1) ISO4414: Pneumatic Fluid Power - Recommendations for the application of equipment to transmission control systems. *2) JISB8370: General Rules of Pneumatic System. 3/21 For decision of conformity of pneumatic equipment, the designer of a pneumatic system or a person deciding the specifications is requested to render judgment. Since pneumatic equipment is used in many kind of situation, the decision for adaptability of system is depended on the designer or a person deciding the specifications to judge by the result of analysis and testing report if necessary. The guarantee of the performance and security which expected is up to the responsibility of the person who decides the adaptability of system. Construct the system with consideration of the possibility of machinery trouble by checking up the details specifications through latest product catalog and others documents. Operators with sufficient knowledge and experiences should operate the equipment. Compressed air, if handled wrongly, will cause a hazard. Personnel with sufficient knowledge and experiences only are requested to assemble, operate or maintain machines and devices which use pneumatic equipment. Do not handle the machines and devices or remove the equipment until safety is confirmed. 1) Inspect or service the machines and devices after making sure of measures taken securely for prevention of drop of driven bodies and out-of-control run of them. 2) Remove the equipment after making sure of the safety measures mentioned above duly taken and exhausting compressed air in the system. 3) When restarting the machines and devices, make sure of a measure taken for prevention of protrusion in advance. Use the product in environment conforming to the specifications. You are requested to be sure to inform us in advance, when you intend to use the product outdoors or for applications likely to have large effects on people and properties and requiring safety in particular such as atomic energy, railways, aircraft, rolling stocks, medical equipment, equipment to be in touch with beverage and foodstuff, amusement equipment, emergency shut-off devices, press safety devices, brake circuits and safety equipment.
4 2. Precautions for Operation of Pneumatic Cylinders Precautions on related legislation 4/21 When using a compressor that the rated discharge pressure is over 5Mpa, or an air pressure that is supplied from an air tank over 1Mpa are covered in High Pressure Gas Safety Law. When using a single gas such as Nitrogen, using a container of over 1Mpa as an air pressure source is also covered in High Pressure Gas Safety Law. Precautions on related design General purpose pneumatic cylinder DC7 series is designed to be used in an air system only. If working with fluid other than air, an accident or trouble may be caused. An air cylinder may jump out at a speed higher than expected, if its mechanical sliding area is disordered. Design the cylinder so that the machine may operate smoothly and the cylinder may not damage persons or machines. Fit a protective cover when the cylinder or driven body is likely to cause a hazard to persons. When required frequency of operation is high or the cylinder is mounted on a place exposed too much vibration, adopt a fastening method not to allow the fixed area or connection of the cylinder to loosen. Take safety measures with power failure and possible trouble with the power source taken into consideration. Conduct design so the motions of the cylinder may not cause damages to persons and machines and devices at the occasion of emergency stop, systems error or restarting. Precautions on selection This cylinder is designed to be used in an industrial compressed air system only. Confirm the specifications and do not use out of the range of specifications. Use the cylinder in a proper working pressure within the pressure range. Do not apply exceeded pressure that over the upper limit of working pressure range. Use the cylinder in a proper temperature environment within the working temperature range. Confirm the temperature is within this range even when the cylinder is heated by radiant heat or heat transfer. Supply an air pressure to the cylinder that commensurate with the loads. If the supply pressure is minimized, it may cause instable operation. In the case of an air cylinder, accurate interim stopping accuracy such as that of a hydraulic cylinder cannot be obtained because of compressibility of air.
5 5/21 Zero leak of an air cylinder and air valve is not guaranteed. Do not use the cylinder in environments or for applications where leak of air from a cylinder or valve poses a problem. Be sure to calculate the cylinder buckling. The strength in the case that the piston rod is regarded as a long column, the buckling strength, cannot be enhanced by adopting highly tension-proof steel or heat treatment. When buckling occurs to a cylinder, the cylinder rod may be bent, causing malfunctions or serious accidents. If cylinders are used in the places under unfavorable conditions, where are subjected to wind, rain, and dusts, the piston rod especially needs to be protected. When selecting the boots, consider the environment conditions and temperature. If the boots are provided, the length of extended cylinder rod is changed. Be sure to check the dimension drawing. The volume of boots will change by move of piston rod, and therefore there is a window for air flow (with filter) in the boots, through which small foreign matters of liquid and particle might be entered with air flow. In such a case the boots does not work. Boots type and resistible temperature Code Name Material Resistible temperature J Nylon tarpaulin Vinyl-coated nylon cloth 80ºC JN Chloroprene Nylon cloth coated with chloroprene 100ºC JK Conex Silicon-coated Conex cloth 200ºC Note 1. Remember that the resistible temperatures in the table above are for the boots, not for the cylinder. 2. Conex is the registered trademark of Teijin Ltd. 3. Neoprene, the older name of chloroprene, is the registered trademark of DuPont-Showa Denko Co., Ltd. Thus, we have adopted general name, chloroprene. Precautions on air pressure source Use clean compressed air. Air containing chemicals or corrosive gas will cause break or malfunction of the cylinder. Mount an air filter to remove foreign matter in compressed air. Set an after-cooler, air dryer or air filter to remove drain in compressed air. Precautions on operating environment Do not use the cylinder in environment under corrosive gas or a place exposed to splash of corrosive chemicals or solutions. For cylinder material, see the catalog. Attach a cover to the piston rod in a much dusty place or a place exposed to water drops or oil drops. It is dangerous that the strength of material may be decreased by corrosive in a salty atmosphere. Be
6 6/21 sure to use a cylinder with corrosion proof or corrosion resistant material in such kind environment. In the case of use in the places where splashed with solvent, cutting oil and coolant may deteriorate the quality of seal parts and may cause air leakage at the early stage. Be sure to check the adaptability of packing material. Precautions on installation Be sure to couple the rod with the rod axial center adjusted to the rod moving direction. Otherwise, the bush and rod surfaces, tube inner surface and packing will be worn out or broken. When a cylinder is mounted with fixed (Foot type or Flange type), we recommend using the floating joint with self-aligning function. Do not bump things against the cylinder tube, piston rod, etc. to scratch them. Scratched sliding area will cause wear of packing. For the mounting of cylinders, use bolts of the specified size, and fix with the bolts of the strength class. And, be sure to fix the bolt by using a tool that can get an adequate clamping torque. Install an external stopper to the mounting base when using foot type mounting to prevent direct application of impact. Apply grease to rotary areas of trunnion accessories and clevis accessories to prevent seizure. If the boots are provided, conduct mounting with care not to twist the boots Precautions on piping Flush the piping sufficiently to remove foreign matters. Be careful so that no seal tape or sealing material may enter the pipe. When wrapping a seal tape around threaded area of the piping or joint, wrap the tape leaving 1 to 2 threads at the end as untapped. Conduct the piping work in conformance with the regulations of the applicable country. Proper torque for piping When fastening a joint, tighten the joint to the torque shown below. Connecting thread Proper tightening torque (Nm) Connecting thread Proper tightening torque (Nm) Rc 1/8 7 to 9 Rc 1/2 28 to 30 Rc 1/4 12 to 14 Rc 3/4 60 to 65 Rc 3/8 22 to 24 Rc 1 70 to 75
7 Precautions on lubrication 7/21 Use the lubricating oil of Turbine Oil Class 1 ISO VG32 or equivalent. Do not use a spindle oil or machine oil, since they will shorten the life of seals to cause malfunction of the equipment. Be sure to continue lubrication to the last, once started. Stop of lubrication on the way will cause malfunction of the equipment due to loss of initial lubrication. Precautions on trial operation and adjustment When starting up a device, increase the supply pressure from a low pressure gradually to check that the device operates smoothly. Be sure to attach a speed controller on the cylinder to adjust setting speed from the low speed side gradually. The cylinder with pneumatic cushion is adjusted to the intermediate speed position before shipment. Adjust the cushion needle position from the low speed side gradually according to the operating condition. If energy higher than the capacity of the pneumatic cushion should apply, collision of the cover with the piston will take place in some cases, resulting in damage with the machine or device. Check whether there is any abnormal motion, noise or friction heating during the trial run of cylinder. If any abnormality is found, do not use the equipment until specified countermeasures are taken. Precautions on maintenance and inspection To remove or disassemble equipment, take measures for prevention of drop of components and run out of control of the equipment, exhaust compressed air in the system, and make sure of safety in advance. There still may be residual pressure even when the supply pressure is exhausted depending on the working circuit. Remember to exhaust the compressed air completely before removing the cylinder for disassembling. Drain the pneumatic system periodically. Check the pneumatic equipment periodically. If any abnormality is found, do not use the equipment until specified countermeasures are taken. Before disassembling a cylinder, the operator has to completely understanding the inner structure by structural drawing or assembly drawing. To disassembling a single acting cylinder which built-in with spring, be careful that the spring may jump out. Before disassembling, make sure in advance that the inner structure and the spring force.
8 Precautions on storage 8/21 Consider following points under storage of product. 1. Become rusty 2. Permanent stress of packing Store the product as followings. 1. Store the product in a cold and dark place (37ºC max.) protected from direct sunlight and moisture in position 30cm above the floor level. 2. Transportation causes a hazard, if collapse of cargo should take place due to excessive vibration. Further, parts may be damaged due to excessive vibration. Precautions on scraping Disassemble cylinders, sort the disassembled components by material (iron, copper, aluminum, resin, rubber, waste oil, etc.), and then, dispose them. Piston rods are hard chrome plated. When disposing them, consult with a disposal company. Dispose resin base and rubber base components as nonflammable wastes.
9 Temperature 3. Instructions for use Environmental conditions Use cylinders only within the allowable working temperature range. Otherwise, troubles below may occur. 1. When cylinders are used at the temperature lower than the lower limit of the working temperature range: Brittle fracture due to lowered stretch of cylinder material Air leak due to lowered elasticity of packing 2. When cylinders are used at the temperature higher than the upper limit of the working temperature range: Rust-proof measures Damage due to lowered strength of cylinder material Damaged packing Galling due to thermal expansion in the slipping part 9/21 The use and storage of cylinders in the places where are highly humid, or are splashed with water or sea water require the consideration of rust-proof and anticorrosion measures. In such a case, contact us. Installation location 1. Use cylinders only indoors. 2. Avoid the use in the places where are subjected to dusts and vibrations. DO NOT use them under the environmental conditions shown below. The use under these conditions requires the protection of the rod part, rust-proof measures, review of part material, magnetic shield, and vibration proof measures. If any countermeasure required for the cylinder side, contact us. Working environmental conditions Sands, dusts, soil, chips, welder spatter, etc. Rain, water, sea water, oil, chemicals, etc. Direct sunlight (ozone), humidity, etc. High temperature, low temperature, freezing, etc. Highly magnetic field Vibrations Mounting For the mounting of cylinders, use bolts of the specified size, and fix with the bolts of the strength class. In the case of the rotary type, use pins of the specified size. Otherwise, screws may be loosened or damaged due to cylinder driving force or its reaction force. When a cylinder is mounted with fixed, the performance of the cylinder largely depends on the hardness of the mounting material. Therefore, insufficient hardness of mounting material may lead to a warp in mounting material due to the driving force of the cylinder and the disordered piston rod and bush, causing premature wear and the damaged thread of the piston rod. Use the mounting material with sufficient hardness.
10 (LA, LB, FA, FB types) Mounting of rod end in the case of fixed type 10/21 The movement direction of articles moved by a cylinder must be always aligned with the axis center of the piston rod movement. If the axis center is run out, premature wear of the bush, baking or galling of the cylinder tube may occur. To check the run out of the axis center, be sure to measure the core deviation of mounting part of the article at the position where the piston rod is fully ejected, and align the core. Then, connect the cylinder with the article. Mounting of cylinder Consider the following points when mounting cylinders. We cannot take responsibility for malfunctions due to wrong cylinder mounting. In the case of fixed type 1. LA, LB type To mount LA and LB types, fix the attachments with clamping bolts. However, remember that this procedure is not perfect for the move in the axial direction when a load is applied. Therefore, install the stopper to the mounting base, as shown in the figures below.
11 2. FA, FB types 11/21 Fix cylinders as shown in the figures below. In the case of rotary type For the cylinder of which mounting part moves inside a plane, be sure to connect the connection fittings of the rod end with pins, so that the mounting part can move inside the plane. For the plane and rectangular direction, perform centering similarly to the fixed type. Be sure to apply lubricant to the bearing part of the connection fittings. DO NOT use floating joints for rod end attachments. 1. CA, CC, CB, CD type attachments Use pins of the size specified in this catalogue. In the case of a long stroke (1000 mm or longer), avoid horizontal mounting. Otherwise, a lateral load is applied to the bush part due to the weight of the cylinder, causing uneven abrasion, substantially shorter service life, or galling. 2. TA, TC type attachment Mount counterpart attachments at a right angle so that they are vertical with the trunnion boss. If they are mounted slantingly, uneven abrasion may occur in the boss bearing area, causing a substantially shorter service life.
12 12/21 Leave a minimum space between trunnion and counterpart attachments. And, to avoid bending moment boss bearing must be always aligned with the axis center of the pin. Conformation of air supply Operation 1. Confirm the cooler and dryer are working properly when those devices are connected. 2. Drain the pneumatic system periodically. Conformation of working pressure range 1. Table below shows the working pressure range. Confirm the pressure is within this range even when the pressure fluctuates greatly. Cylinder type Standard Valve set Working pressure range 0.05 to 1.0Mpa (Double-rod : 0.1 to 1.0MPa) 0.17 to 0.7Mpa 2. When starting up a device, increase the supply pressure from a low pressure gradually to check that the device operates smoothly. Conformation of working temperature range Table below shows the working temperature range. Confirm the temperature is within this range even when the cylinder is heated by radiant heat or heat transfer. Cylinder type Standard Valve set Working temperature range -10 to +70ºC (But do not use when frozen) +5 to +50ºC Adjustment of cushion valve Adjust the cushion valve as followings. Even if the cushion is adjusted when delivery, the change of damping effect of cushion will occurs depend on the speed and load of cylinder. 1. Loosen the cushion lock nut with a spanner. 2. Turn the cushion valve only with an Allen wrench. a) Turn clockwise: the cushion stroke speed decreases. b) Turn counterclockwise: the cushion stroke speed increases. 3. After the adjustment of the cushion valve is complete, fix the cushion valve with an Allen wrench, and clench the cushion lock nut.
13 13/21 Allowable shock absorbed range of cushioning The cushioning mechanism decreases piston speed by applying back-pressure in the interval of about 20mm from stroke end (interval length varies depending on bore). Therefore, beware of the mechanism s limitations, shown in the graph at right. Adjustment of cylinder speed Maximum cylinder operating speed is 700mm/sec. If this speed is exceeded, the rod gland and seals will rear rapidly and the shock at stroke end will increase. The result is shortened cylinder life time and susceptibility to malfunction. If cylinder speed is too low, the result will be sticking, slipping and unstable operation. Cylinder speed varies depending on pipe diameter, air pressure, flow rate and load, and therefore must be adjusted to suit the intended use. Adjustment is normally done using a speed control valve, but this is not always enough, and other factors may have to be considered (air pressure, load etc.). Piping Take sufficient care to avoid dusts and chips of pipes in the piping. When piping, avoid any air accumulation in pipes. When connecting with a rubber hose, do not bend it with the bending radius smaller than the specified level. Be sure to perform piping flushing. After flushing is complete, connect to the cylinder. Otherwise, the cylinder may be malfunctioned or leak may occur due to dusts in the piping. Other notes When welding near a cylinder, it may be subjected with spatters. Protect the cylinder rod to avoid spatters. When welding during mounting, take sufficient care to avoid an electric current in the cylinder. Any electric current in the cylinder may lead to arcs between the rod and bush or between the piston and tube, causing the damaged cylinder parts. We recommend using JIS K class (equivalent of additive free turbine oil ISO VG32 for lubrication. The packing may be distended depending on the class of oil, and may trigger the oil leak. Be sure to continue lubrication to the last, once started. Stop of lubrication on the way will cause malfunction of the equipment due to loss of initial lubrication. If the inclusion grease is cleaned out, it may cause the early abrasion and seizing.
14 14/21 Do not use when frozen. If operating when frozen, the packing may be fractured or scrapped at the slide part. Do not too turning counterclockwise to loosen the cushion valve. It may be blasted off by the air pressure. Maintenance (maintenance and inspection) To use cylinders without an accident for a long time, daily and regular inspections are required. 1) Daily inspection For the daily inspection, check the points described below. (1) Check that the cylinder set bolts and nuts are not loosened. (2) Check that the working conditions are normal. (3) Check that there is no external leakage. (4) Check that there is no abnormality in other parts of the cylinder (tie rod, flange, etc.) 2) Regular inspection (disassembly inspection) Decide the interval of the regular inspection depending on the working conditions and requirement, and perform according to the decided schedule. It is recommended to perform it once a year. Replace packing and gasket with fresh ones at regular inspections. Do not use packing which have been stored for two years or more. Notes on fitting of valve seals Valve seals must be fit in the specified direction and sequence. Wrong fitting direction and sequence will lead to the damaged packing, causing oil leak.
15 4. Precaution for Operation of Switches Precautions on design and selection 15/21 Use the cylinder within the specified operating ranges. Use at load current, voltage, temperature, impact and others in excess of specifications will cause rupture or malfunction of the cylinder. When inductive load such as relay and solenoids is connected, be sure to set a contact protective circuit, since surge voltage is generated. When switch wiring extends over a long distance, switch contact may be broken by inrush current. Be sure to set a contact protective circuit. Series connection of switches with indicating lamps will cause voltage drop due to indicating lamp internal resistance. Further, load may not operate, even if the switch operates. In the case of 2-wire type non-contact switch, current (leak current) to actuate the internal circuit is flowing into the load, even if the switch is in the OFF position. In the case of parallel connection in particular, check the load working current. The switch is actuated by the magnet incorporated in the cylinder. In the case of excessive access, magnetic forces on both sides interfere with each other to cause malfunction of the switch. Further, do not use the switch in an environment of strong magnetic field, since the switch may malfunction in such an environment. When the switch is used in an interlock circuit requiring high reliability, set a mechanical protective function to provide for a possible trouble, or adopt the double interlock system such as installation of a sensor in addition to the cylinder switch. As to detection on the way of piston stroke, be careful of responsibility of the load. When the piston speed is high, it is possible that the load cannot follow operation of the piston. Work out design with space required for maintenance and inspection taken into consideration. Precautions on mounting and adjustment Do not drop or throw a switch. The inside of a switch may be damaged. Do not hold the switch lead wire to carry the cylinder. The inside of a lead wire may be broken. Fix the switch securely while strictly observing the specified tightening torque for screws. Application of excessive tightening torque may break the switch. Set the switch at the center of the working range. If the switch is used at the end of the working range, detection may be unstable.
16 Precautions on wiring 16/21 Do not connect the switch directly to a power source. All switched must have the required load (relay, sequencer, etc.) installed between them and the power source. Check the wiring for insulation properties. If there is a short, the switch may break instantaneously due to over current. Avoid use of wiring commonly for the motive power sources or high-voltage cable. The switch may malfunction due to noises. Be careful so that repetitive bending or pulling force may not apply to the lead wire. Otherwise, the lead wire will be broken. Be careful of wrong wiring. Connect according to the color of a lead wire. Precautions on operating environment DANGER Never use the switch in an ambience of explosive gas. The switch is not explosion-proof. When the switch is used in an ambience of explosive gas, the switch may cause an explosion hazard. Be fully careful never to use the switch in an ambience of explosive gas. Do not use the switch where a magnetic field is generated. Malfunction of the switch or demagnetization of the magnet in the cylinder may be caused. Do not use the switch in an environment where it is exposed to splashing of water at all times. The switch conforms to IEC Standard IP67, but imperfect insulation may be caused in some cases, if it is exposed to continuous splashing of water. Do not use the switch in an environment where it is exposed to oil such as cutting oil or chemicals. Do not use the switch in an environment where it is exposed to excessive impact. In the case of a contact switch, the contact may malfunction, resulting in instantaneous output of a signal. Do not use the switch in an environment where there is a noise generation source. If there is a large noise generating equipment (such as electromagnetic lifter, high frequency induction furnace and motor) in vicinity of the non-contact switch, deterioration or break of the switch internal circuit element may be caused. Take counter-measures against noise at the generation source. Also, be careful not mix or touch the line with other lines.
17 17/21 Avoid accumulation or access of magnetic substances. Much deposit of chips or weld spatters around the switch with deprives the cylinder of the magnetic force in some cases, resulting in malfunction of the switch. Even if the operating temperature is within the specified range, the switch internal parts may be affected adversely, if abrupt temperature change should take place. Precautions on maintenance Retightening the switch mounting screws as needed. At that time, check and switch mounting position and conduct readjustment, if necessary. Check the lead wire for damage. If the lead wire cover is damaged, imperfect insulation or break in wiring may result. In such a case, replace the switch or the lead wire promptly.
18 18/21 How to adjust the switch detecting position. 1. Loosen the two set screws with an Allen wrench, and move them along with the tie rod. 2. Adjust the detecting position (for the 2-LED type, the position that the green lamp lights up) 2 to 5 mm (about half of the working range is appropriate) before the required position that the switch indicator lamp starts to light up (ON). Then, gently hold the top of the switch so that the cylinder tube contacts the detecting face of the switch, and clamp the set screw with the appropriate clamp torque. Note) Inappropriate clamp torque may cause the off center of the switch position. 3. The indicator lamp lights up when the switch is set to the ON position. 4. Switches can be mounted to any of four tie rods and on the most suitable position depending on the mounting space of the cylinder and wiring method. 5. Mount a switch to the most suitable position to detect the stroke end with the Switch mounting dimension (dimension UX). 1. Loosen the two set screws with an Allen wrench, and move them along with the tie rod. 2. Adjust the detecting position (for the 2-LED type, the position that the green lamp lights up) 2 to 5 mm (about half of the working range is appropriate) before the required position that the switch indicator lamp starts to light up (ON). Then, gently hold the top of the switch so that the cylinder tube contacts the detecting face of the switch, and clamp the set screw with the appropriate clamp torque. Note) Inappropriate clamp torque may cause the off center of the switch position. 3. The indicator lamp lights up when the switch is set to the ON position. (The lamp lights out when the switch is set to ON position for SR405 type.) 4. Switches can be mounted to any of four tie rods and on the most suitable position depending on the mounting space of the cylinder and wiring method. 5. Mount a switch to the most suitable position to detect the stroke end with the Switch mounting dimension (dimension UX).
19 5. Precaution for Operation of Valves Precautions on design and selection 19/21 DANGER Do not use other than as a valve for press in the press machine or for control of clutch brake. There is no monitoring system or security system installed in the general solenoid valve. An accident of operators and damage of equipment may be occurred when getting trouble. Never use the valve in an ambience of explosive gas. The valve is not explosion-proof. When the valve is used in an ambience of explosive gas, it may cause an explosion hazard. Be fully careful never to use the valve in an ambience of explosive gas. Be sure to use within the specifications range that show in the catalog. Be sure to handle the product with completely understanding of JIS symbols and the operating principles. There is differ of valve performance depends on the operating principles when pressuring compressed air, applying current or stopping the air and current. Do not use the cylinder in environment under corrosive gas or a place exposed to splash of corrosive chemicals or solutions. Be sure to cover the valve with a cover or panel, etc. if using the valve in an environment where it is exposed to splashing of water, cutting oil or chemicals. Take measures of using DIN socket drip-proof valve, if it is exposed to splashing of water. There will be heated over ambient temperature by the current condition of the solenoid valve. Be sure to take measures of cooling down the temperature within working temperature range if the valve is installed next to any panel or box and manifolds, etc. The pilot type valve will not be switched until the pilot pressure is to reach the designated pressure. The spring returned type valve or 3 positions valve that holding by spring force at normal position (the position when there is no control signal.) will be caused an accident of operators and damage of product when the supply pressure is lower than the working pressure range at the period of switching. The actuator may move rapidly caused by the drop-out back pressure, when exhaust center valve is switched from normal position. To prevent occurrence of an accident of operators and products, be sure to handle carefully under safety ensuring. If the solenoid valve is operated by the programmable controller, and if there is a CR circuit for contact protect, the leak current of output should be set at 5% less of holding current. Otherwise the valve may be malfunctioned even when turned off. Be sure to set a contact protective circuit, since surge voltage is generated when the solenoid valve is turned off. Otherwise, the connect point of control device may be damaged. (Simultaneously, the solenoid will be also protected from the external surge voltage.)
20 Do not input two control signals to the detent type or 3 position type valve. 20/21 When operate the actuator at intermediate stop position by using closed center type valve, malfunctioning may be caused by the compressibility of air that inside the piping between valve and actuator. And also, if there is any leak at the actuator, piping or fitting and valve, the intermediate position will not hold for long period. We recommend installing also a mechanical intermediate stop holding when the valve is used as load holding. Precautions on air pressure source Infiltration of moisture in compressed air into the cylinder as drain may cause a trouble. Take sufficient measures such as setting of filter of 40 µm max to strictly control the moisture. In the case of occurrence of oil mist, use a mist separator to prevent infiltration of oil mist into the cylinder. Precautions on installation To remove or disassemble valve and wiring of solenoid, take measures for run out of control of the equipment, and exhaust compressed air in the system, and make sure of safety in advance. Precautions on lubrication Lubrication is not required. But, when conducting lubrication, perform spray lubrication using a lubricator. Use the lubricating oil of Turbine Oil Class 1 ISO VG32. Do not use a spindle oil or machine oil, since they will shorten the life of seals to cause malfunction of the equipment. Be sure to continue lubrication to the last, once started. Stop of lubrication on the way will cause malfunction of the equipment due to loss of initial lubrication. As to the lubricating oil, use lubricating oils specified by MSDS. Precautions on trial operation Do not operate the manual button at the time other than switching the solenoid valve without turn on the solenoid in the case such as trial operation. The lock must be released after the operation in the case of button with lock.
21 21/21 Return the actuator to the original position after the operation in the case of detent type valve. Otherwise, the actuator may be malfunctioned. Do not operate two manual buttons simultaneously in the case of detent type and 3 position type valve. Precautions on maintenance Check whether the valve is operating properly once per month (30days) even when operate infrequently.
INSTRUCTION MANUAL HEAVY DUTY TYPE PNEUMATIC CYLINDER 10A-2 (R) SERIES
No: 08-T063 INSTRUCTION MANUAL HEAVY DUTY TYPE PNEUMATIC CYLINDER 10A-2 (R) SERIES Wrong operation of the product may result in unavailability of exhibition of full performance
More informationDisassembly / Reassembly Procedure
08-T059 Disassembly / Reassembly Procedure HEAVY DUTY TYPE PNEUMATIC CYLINDER 10A-3 SERIES Failure to observe the instructions given in this manual could cause this equipment
More informationRotary Actuators Precautions 1 Be sure to read this before handling.
Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures or temperatures, etc.,
More informationDoc. no.ck1*-om0066p. PRODUCT NAME Clamp Cylinder. MODEL / Series / Product Number
Doc. no.ck1*-om0066p PRODUCT NAME Clamp Cylinder MODEL / Series / Product Number CK1*40&63-**Z CKG1*40&63-**Z-** CKP1*40&63-**Z-** Contents Safety Instructions P2 1. Specifications P4 1-1. Specifications
More informationMagnetic Field Resistant 2-color Indication Type Solid State Auto Switch
PRODUCT NAME Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch MODEL / Series / Product Number D-P3DW(A) * Series Contents Safety Instructions 2 Model Indication Method 8 Names and
More informationITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa
5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,
More informationLow Torque Rotary Joint
Low Torque Rotary Joint Series MQR Metal Seal Type K Long service life billion rotations MQR : billion rotations MQR : 0. billion rotations MQR : 0. billion rotations MQR8 : 0. billion rotations MQR: 0.
More information3-Way Ball Valve Type 23H
Serial No. H-V062-E-4 contents 3-Way Ball Valve Type 23H User s Manual (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instruction for transportation,
More informationPneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure,
Pneumatic components (Electro pneumatic Regulator) Safety Precautions Read this before starting use. Please refer to Intro 43 for general details on the pneumatic components, and to " Precautions" in this
More informationTwo Hand Control Valve
Two Hand Control Valve Series n output is available through synchronized, twohanded operation (within 0.5 s)! Conforming to EN574 RoHS (Interchangeable with XT92-67 ) Example of a basic circuit diagram
More informationDiaphragm Valve Type 14 Pneumatic Model Type AV
ASAHI AV Valves Serial No. H A015 E 1 Diaphragm Valve Type 14 Pneumatic Model Type AV User s Manual (1) General operating instructions Contents (2) General instructions for transportation, unpacking and
More informationButterfly Valve Type 58 (PDCPD)
Serial No. H-V074-E Butterfly Valve Type 58 (PDCPD) 700mm (28 ) User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General
More informationSeries variation. Auxiliary valve. Quick exhaust, and circuit switchover valves, etc. are available. Port size (Rc) Page. Model Product appearance
Series variation Quick exhaust, and circuit switchover valves, etc. are available Model Product appearance Model no. Port size (Rc) Page 4 dia. dia. M /8 /4 /8 / /4 /4 / QEV-A Quick exhaust valve QEV-8A
More informationDiaphragm Valves Type 15
Serial No. H-V031-E-8 Diaphragm Valves Type 15 User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for
More informationButterfly Valve Type 57P
Butterfly Valve Type 57P Contents Lever Type: 50-200 mm (2-8 ) Body Material: CPVC Gear Type: 50-200mm (2-8 ) Body Material: CPVC (1) Be sure to read the following warranty clauses of our product 1 (2)
More informationGATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1
Serial No. H-V011-E-12 GATE VALVES Type P (Standard: Plug) Type S (Soft Seal) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions
More informationROD SLIDERS INDEX ACTUATORS GENERAL CATALOG. Characteristics 779. Handling Instructions, and Precautions 783
Presenting our CAD drawing data catalog ACTUATORS GENERAL CATALOG ROD SLIDERS INDEX Characteristics 779 Handling Instructions, and Precautions 783 Standard Cylinders Specifications 785 Order 78 Dimensions
More informationSolid State Auto Switch D-M9#A#
PRODUCT NAME Solid State Auto Switch MODEL / Series / Product Number D-M9#A# Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 10 Summary of Product parts 10 Definition
More informationInstallation,Operation and Maintenance Manual H-V016-E-10. Serial No. 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1
Serial No. H-V016-E-10 Gauge Valve 目次 ( ページ ) 1. Be sure to read the following warranty clauses of our product 1 2. General operating instructions 2 User s Manual 3. General instructions for transportation,
More informationSoft Start-up Valve. AV2000/3000/4000/5000 Series
Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off
More informationLow Torque Rotary Joint
Low Torque Rotary Joint MQR Series Metal Seal Type Long service life billion rotations MQR : billion rotations MQR : 0. billion rotations MQR : 0. billion rotations MQR8 : 0. billion rotations MQR: 0.
More informationOperation Manual. Document No.: KE KITZ EKSR Series Spring Return Type Electric Actuators. For KITZ Ball Valves
Document No.: KE-4041-00 Operation Manual KITZ EKSR Series Spring Return Type Electric Actuators For KITZ Ball Valves Thank you for choosing KITZ products. For safe and trouble-free function and performance
More informationSeries AV2000/3000/4000/5000
Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU
More informationNo.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1
No.EX -OME0016-A PRODUCT NAME SI unit MODEL / Series / Product Number EX140-SDN1 Table of Contents 1. Safety instructions 2 2. Specifications 7 2-1. General specifications 7 2-2. Electrical ant network
More informationACTUATORS GENERAL CATALOG
CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG ROTARY ACTUATORS PISTON TYPE SERIES CONTENTS Features 1223 Specifications 1224 Inner Construction, Major Parts and Materials 1226 Order
More informationDoc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number
Doc. no. Coolant valve PRODUCT NAME VNC/VNH Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions
More informationTECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES
TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS "" includes all sensors that detect the presence of a metallic object approaching the sensing face or near the sensing face without mechanical contact.
More informationDiaphragm Valve Type 72
Serial No. H-V001-E-8 Diaphragm Valve Type 72 User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for
More informationButterfly Valves ASAHI AV VALVES
Serial No. H-V030-E-8 Butterfly Valves Type 56: 400mm (16 ) Body: PP, PVDF Type 75: 450-600mm (18-24 ) Body: PP, PVDF Type 56D: 400mm (16 ) Body: PDCPD Type 75D: 450-600 mm (18-24 ) Body: PDCPD Contents
More informationAir Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) User s manual. Air Release Valve. Air Release Valve for Water
Serial No. H-V035-E-3 Air Release Valve (PDCPD) Air Release Valve for Water (PDCPD + Epoxy Resin Coating) Contents (page) User s manual () Be sure to read the following warranty clauses of our product
More informationSpeed Controller High Flow
http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Speed Control Valve for High Speed Cylinder High Flow Speed Control Valve for Actuator. High Flow Type with Same Size as. Suitable for
More informationINSTRUCTION MANUAL FOR
SM-50701-A/1 INSTRUCTION MANUAL FOR High vacuum air-operated valve AVB **7 Before using this product, thoroughly read this instruction manual. In particular, read the safety precautions carefully. After
More informationHigh Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series
Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating
More informationLock unit MWB*32&100-UT-* MWB*32&100TN-UT-* MWB*32&100TF-UT-*
Doc. no.mwb*-om0078q PRODUCT NAME Lock unit MODEL / Series / Product Number MWB*32&100-UT-* MWB*32&100TN-UT-* MWB*32&100TF-UT-* Contents Safety Instructions P. 3 1. Product Specifications P. 5 1-1. Lock
More informationSolid State Auto Switch
PRODUCT NAME Solid State Auto Switch MODEL / Series / Product Number D-M9## D-M9#W# Contents Safety Instructions 2 Model Indication and How to Order 9 Summary of Product parts 10 Definition and terminology
More informationTechnical information for LFU20-Z07-3A-X2
Technical information for LFU20-Z07-3A-X2 Ultrasonic flow sensor and flow controller Applications: closed-loop flow control. Also requires fluid regulator (separate part) Ultrasonic flow sensor IN18796_LFU
More informationcontents (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 User s Manual
Serial No. H-V003-E-12 contents 3-Way Ball Valve Type 23 User s Manual (1) Be sure to read following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instruction for transportation,
More informationDoc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number
Doc. no. Process valve PRODUCT NAME VNA Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Design
More informationExhaust Throttle (Needle) Valve ET
http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Exhaust Throttle (Needle) Valve Exhaust Throttle (Needle) Valve ET 494 Exhaust Throttle (Needle) Valve with Silencer. Directly Connectable
More informationVacuum pump system type
type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated
More informationCoolant valve. SGC/SGH Series
Doc. no. PRODUCT NAME Coolant valve MODEL / Series / Product Number SGC/SGH Series Contents Safety Instructions ------------------------------------------------------------------------------------- 2,3
More informationBalancing Unit BBS Series
Lightly supporting heavy objects just with air Balancing Unit BBS Series Balancing Unit BBS Series CC-960A Move objects weighing up to 200 kg effortlessly! Balancing Unit BBS-A
More informationFree position locking flat and compact cylinder UFCD Series
Space-saving cylinder ensures safety during work in power failures or accidents. Free position locking flat and compact cylinder UFCD Series Free position locking flat and compact cylinder UFCD Series
More informationDiaphragm Valve Type 14 Pneumatic Actuated Type AV
Serial No. H-A015-E-7 Contents (1) Be sure to read the following warranty clauses of our product 1 Diaphragm Valve Type 14 Pneumatic Actuated Type AV (2) General operating instructions 2 (3) General instructions
More informationKV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)
CAT.1101E-S www.sym1.com KV series Innovatively detachable Manifold Block (DIN Rail Mounting) Smart Solenoid Valve (Plug-in type, D-SUB multi-connector ) Compact size with large flow capacity Exceedingly
More informationDoc. no.cm2*-om0064p. PRODUCT NAME Air cylinder. MODEL / Series / Product Number
Doc. no.cm2*-om0064p PRODUCT NAME Air cylinder MODEL / Series / Product Number C*M2**-*Z C*M2**-*Z-XC85 C*M2**-*Z-X446 Contents Safety Instructions P2 1. Specifications P4 1-1. Specifications 2. Installation
More informationEX Series. Electric Actuators for Ball and Butterfly Valves
EX Series Electric Actuators for Ball and Butterfly Valves Next-Generation Electric Actuator Realization of Upgraded General-Purpose Actuators The modularization and adoption of the common parts have brought
More informationOPERATION MANUAL. Diaphragm Pump. TD/TD2 Series TD-08, 15, 20/TD2-25. Introduction
Mechatronics Group OPERATION MANUAL Diaphragm Pump TD/TD2 Series TD-08, 15, 20/TD2-25 Thank you for purchasing Diaphragm Pump. Introduction This operation manual describes how to ensure safe and prolonged
More informationHigh Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series
Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating
More informationAdded 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model
Blow Gun Series 20% reduction in power consumption with the SMC Blow gun + S coupler + Coil tube 10% reduction with the Blow gun () only RoHS With cover Extension nozzle Added mm and 150 mm lengths Pressure
More informationDiaphragm Valve Type 14 Pneumatic Actuated Type AP. User s Manual. Contents H-A065-E. Serial No.
Serial No. H-A065-E Diaphragm Valve Type 14 Pneumatic Actuated Type AP User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3)
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More informationDoc. No.VT307 -OMH0001-C. 3 Port Direct Operated Solenoid Valve PRODUCT NAME. VT307 Series MODEL/ Series
Doc. No. 3 Port Direct Operated Solenoid Valve PRODUCT NAME VT307 Series MODEL/ Series Contents Safety Instructions ------------------------------------------------------------------------------- 2,3 Precautions
More informationLow Torque Metal Seal Type Rotary Joint. MQR Series
Doc. No MQR****-OML0002-A. PRODUCT NAME Low Torque Metal Seal Type Rotary Joint MODEL / Series / Product Number MQR Series Contents 1. Contents P1 2. Model / Specifications P2~5 3. Safety Instructions
More informationOperation Manual. Model name. MRHQ Rotary Gripper. Part number / Series MRHQ10,16,20,25
Doc. no. MRHQ-OM00002-C Operation Manual Model name MRHQ Rotary Gripper Part number / Series MRHQ10,16,20,25 - Install and operate the product only after reading the Operation Manual carefully and understanding
More informationRotary Damper. Type 57: 40~350mm (1 1/2 ~14 ) Type 56: 400mm (16 ) Type 75: 450~600mm (18 ~24 ) Contents
Serial No. H-V038-E-8 Rotary Damper Type 57: 40~350mm (1 1/2 ~14 ) Type 56: 400mm (16 ) Type 75: 450~600mm (18 ~24 ) Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General
More informationDesign & Selection. Installation & Adjustment
U SM Series WRNING This product must not be used submerged in water, oil or powder, or where coolant, coolant fluid or swarf, etc., may come in contact. lways incorporate an interlock in the control circuit
More informationPressure Relief 3 Port Valve With Locking Holes
Doc. No. VH*-OMQ0023-B PRODUCT NAME Pressure Relief 3 Port Valve With Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~02A,B(-B,S)(-K,R,Z) VHS30-(F,N)02~03A,B(-B,S)(-K,R,Z) VHS40-(F,N)02~04A,B(-B,S)(-K,R,Z)
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More informationø20, ø32 ø50, ø63, ø80 How to Order Piping direction Flange side Nil Cylinder stroke 15mm 15 (RSH20) 20mm 20 (RSH32) 30 D L Cylinder stroke
Heavy Duty Stopper Cylinder Series RSH/RS1H ø, ø32 ø, ø63, ø How to Order Piping direction Flange side Nil Positional relationship of lever and port RSH Port Direction of transfer 32mm Bore size only 32
More informationSwing Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1
Serial No. H-V013-E-13 Swing Check Valve User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation,
More informationEX Series. Electric Actuators for Ball and Butterfly Valves
EX Series Electric Actuators for Ball and Butterfly Valves Next Generation Electrical Actuator Realization of Upgraded General-Purpose Actuators The modularization and the adoption of common parts have
More informationPush-In Fitting Type Quick Exhaust Valve
http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Valve Valve 482 Suitable for High-Speed Cylinder. Standard Valve is equipped with Silencer. Re-adjustment of exhaust
More informationConstant Flow Valves ASAHI AV VALVES H-V019-E-6. Contents. Serial No. User s Manual
Serial No. H-V019-E-6 Constant Flow Valves User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation
More informationLight weight clamp cylinder CAC-N32/40 Series Light weight position locking clamp cylinder UCAC-N32/40 Series
Helping lighten welding jigs and other tools Light weight clamp cylinder CAC-N32/40 Series Light weight position locking clamp cylinder UCAC-N32/40 Series New product Light weight clamp cylinder CAC-N
More informationBray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual
Bray/ VAAS Knife Gate Valve 760/762/765/766/767/768 Series Table of Contents Definition of Terms 1 Safety Instructions 1 Introduction 2 Unpacking 2 Storage 2 Installation 3 Commissioning 3 Cylinder-Operated
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response
More informationNo. MGP*-OM0047P-B PRODUCT NAME. Remodeled. MODEL / Series / Product Number. Series MGP-Z
No. MGP*-OM0047P-B PRODUCT NAME Remodeled MODEL / Series / Product Number Series MGP-Z Contents Safety Instructions 2 Product feature 4 1. How to Order 5 2. Model 5 3. Specifications 5 4. Standard strokes
More informationDoc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME:
Doc. No. IZ -OML0002-B OPERATION MANUAL PRODUCT NAME: MODEL: Ionizer IZN10 Series Read this operation manual carefully to understand before installation and operation. Pay extra attention on the clause
More informationTrimmer Auto Switch Series D- 7K/D-R K
CAT.ES0-180 B Trimmer Auto Switch Series D- K/D-R K Large work piece OUT1 and OUT are adjustable separately. OUT1 Trimmer OUT Trimmer OUT Medium work piece Small work piece Operating range of sensor (LED
More informationButterfly_Valve_Type57P
Butterfly Valve Type 57P Contents Lever Type: 40-200 mm (1 1/2-8 ) Body Material: PVC, PP, PVDF Lever Type: 50-200 mm (2-8 ) Body Material: CPVC Gear Type: 40-350mm (1 1/2-14 ) Body Material: PVC, PP,
More informationCO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080
CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are
More informationMechanical power cylinder
Attaining thrust equivalent to a hydraulic cylinder -- with air pressure alone! New product Mechanical power cylinder MCP Series Mechanical power cylinder MCP Series CC-958A 1 Realize high thrust at any
More informationAir Operated Valve Control Valve
Air Operated Valve Control Valve -1 Step 0 Type/Structure/Features Please refer to this for structure and feature of Air Operated Valve and Control Valve. Step 1 Selection Please look at the ID chart to
More informationSubmersible Mixed Flow/Axial Flow Pump Model SAM Model SPM
Instruction Manual Installation Manual Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM Thank you for your purchase of the Submersible Mixed Flow/Axial Flow Pump. Teral s Submersible Mixed Flow/Axial
More informationRotary Damper Pneumatic Actuated Type TA
Serial No. H-A030-E-4 Rotary Damper Pneumatic Actuated Type TA Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions
More informationInstruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake
ZJ-267A Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake Instruction Manual Table of Contents Cautions on Safety - - - - - - - - - - - - - - - - - 1 1. Cautions before use - -
More informationContents H-V034-E-12. Serial No. (page) (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2
Serial No. H-V034-E-12 Sediment strainer (Type Y) Contents (page) (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating instructions 2 (3) General instructions
More informationMULTI SLIDERS CONTENTS
CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG CONTENTS Features 923 Handling Instructions and Precautions 925 Specifications 929 Order Codes 930 Inner Construction 931 Dimensions 932
More informationHow to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11
Blow Gun RoHS How to Order VMG W Blow gun Standard type Series Resin body lever type W BU Piping entry Bottom Top Body color White ark blue Symbol Nil 3 4 3 3 4 3 3 33 34 Male High efficiency Low noise
More information[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:
Three-Piece ball valve EA-307 Series PED Category I, II EA-307 User Manual English Version [DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary.
More informationKing Of Valve Co.,Ltd.
Series variation Series Series Series variation SCP* SCP* U Variation Double acting lubrication type Double acting oil-free type, with switch Double acting Stroke adjustable type (Extended) Double acting
More informationConventional specification. External Pilot air specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.
Compact, yet keeps large capacity.» Limited space can be utilized. Standard.» SVR 10 series takes over the functions (Valve variations) of discontinued SVA 10 series. Pneumatic Symbols 5(R) 5(R) 5(R) 5(R)
More informationThrottle (Needle) Valve PP Series
http://www.pisco.co.jp CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Flow Control Valve for Clean Environment Throttle (Needle) Valve 466 Copper alloy free material Nongrease Clean-room
More informationSLIDE TABLES CONTENTS
CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG SLIDE TALES CONTENTS Features 979 Safety Precautions, Handling Instructions and Precautions 981 Specifications 985 Order Codes 986 Inner
More informationInstallation and Operational Instructions for ROBA-stop Holding Brake Type _._
Please read these Installation Instructions carefully and follow them accordingly! Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts. Contents:
More informationSI unit for AS-Interface EX250-SAS#
PRODUCT NAME SI unitfor AS-Interface MODEL / Series / Product Number EX250-SAS# Table of Contents Safety Instructions 2 Product Outline 8 Model Indication and How to Order 9 Summary of Product elements
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More informationDoc. No.VQ4000V-OMV0001. Solenoid Valve PRODUCT NAME. VQ4000/5000 (Pilot Valve V100) MODEL/ Series
Doc. No. Solenoid Valve PRODUCT NAME VQ4000/5000 (Pilot Valve V100) MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time
More informationDoc. No.VQ1000V-OMM0002-B. Solenoid Valve PRODUCT NAME. VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series
Doc. Solenoid Valve PRODUCT NAME VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions
More informationProduct series extended even more! Non-rotating Type. Offers 3 types of non-rotating operation types. push type cylinders. pull type cylinders
The Pen Cylinder s compactness and easy handling make production lines in a broad range of industries. new release with even lighter weight and more PEN CYLINDERS Product series extended even more! The
More informationSediment strainer (Type Y)
Installation,Operation and Maintenance Manual Serial No. H-V034-E-9 Sediment strainer (Type Y) Contents (1) Be sure to read the following warranty clauses of our product 1 User s Manual (2) General operating
More informationAir Catch Sensor ISA2
No.PS##-OMF0007-C PRODUCT NAME Air Catch Sensor MODEL / Series / Product Number ISA2 Table of Contents Safety Instructions 2 Model Indication and How to Order 11 Summary of Product parts 13 Definition
More information1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption
Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A
More informationINSTRUCTION MANUAL. NTN Bowl Feeder Type K10/K14/K16/K20. PMPH001E-f. Before use. Introduction. 1. Before Use. Contents
PMPH001E-f Before use Read this Instruction Manual thoroughly, and operate the machine correctly. INSTRUCTION MANUAL NTN Bowl Feeder Type K10/K14/K16/K20 Introduction Thank you for your purchase of the
More informationCompact direct acting precision regulator
direct acting precision Components preparation and pressure adjustment / unit CONTENTS Product introduction 6 Safety precautions 62 Discrete (RJB500) 624 Block manifold (MNRJB500) 626 Block configurations
More informationOperation Manual For KITZ B Series Pneumatic Valve Actuators
Operation Manual For KITZ B Series Pneumatic Valve Actuators Thank you for choosing KITZ products. For safe and trouble-free function and performance of the product, ensure to read and understand all items
More informationInstallation & Operation Manual
Installation & Operation Manual (I-TORK PDS Series Pneumatic Actuator) PDS-M0108/1010 74-6, Chun Ui-Dong, Won Mi-Gu, Bucheon, Kyoung Ki-Do, Korea Tel : 82-2-855-1365, 66 Fax : 82-2-855-1367 E-mail : roy75@i-tork.com
More informationDoc. No.VG300 -OMH0002-B. 3 Port Solenoid Valve PRODUCT NAME. VG342 Series MODEL/ Series
Doc. No. 3 Port Solenoid Valve PRODUCT NAME VG342 Series MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions on Design
More information