Spartan Controls Millennium Compressor Control Panel Operating Philosophy

Size: px
Start display at page:

Download "Spartan Controls Millennium Compressor Control Panel Operating Philosophy"

Transcription

1 Project: Stock Revision 1 Page 1 Spartan Controls Millennium Compressor Control Panel Operating Philosophy Location: Stock Customer references: Vendor: Vendor document: Spartan Controls Ltd. Operating Philosophy Vendor project: Revision 0 1 Date September 23, 2004 June 2, 2006 Check PM AMB Review DOCUMENT ACCEPTANCE & APPROVAL Certification of acceptance and approval of Revision 0 of this document. Customer name signature: Date: Spartan Controls Ltd. signature: Date: Spartan Controls Ltd. without the prior consent of the Quality Manager of Spartan Controls.

2 Project: Stock Revision 1 Page 2 CUSTOMER SERVICES NETWORK Customer Millennium Operating Philosophy Revision 1 Spartan Controls Ltd. Company Confidential This document is the private property of Spartan Controls Ltd. and must be returned upon request. No part of this document shall be reproduced in any form and distributed outside the Customer Services Network without expressed written consent of Spartan Controls Ltd..

3 Project: Stock Revision 1 Page 3 TABLE OF CONTENTS 1. INTRODUCTION General Standard Base System Optional Functionality START-UP / SHUTDOWN SEQUENCING Compressor Cooldown Stop Alarm Stop (Optional) Engine / Compressor Shutdown Panel Emergency Shutdown (ESD) MANUAL LOADING CONTROL Manual Bypass Valve Control Manual Speed Control Manual Suction Valve Control AUTOMATIC LOADING CONTROL Automatic Speed Control Suction Discharge Automatic Bypass Valve Control Suction Discharge Automatic Suction Control Controlled Unload Blowdown Valve Control COMPRESSOR ROD LOAD CALCUATIONS LOW CLASS P DISCHARGE LOGIC MISCELLANEOUS Password Protection Verify Discrete Input / Outputs Service Mode... 19

4 Project: Stock Revision 1 Page Test Mode Run Time Hours Speed Output Actuator Adjustments MODBUS COMMUNICATIONS Local / Remote Mode APPENDIX A Input/Output List APPENDIX B Definitions... 21

5 Project: Stock Revision 1 Page 5 1. INTRODUCTION 1.1 General This document outlines the Millennium compressor control panel operating philosophy for Bidell Equipment Inc. A Millennium control system will be programmed to safely start, stop, and automatically sequence a two-stage four-cylinder reciprocating compressor with a gas engine driver. The automatic sequence has been designed based on practices and recommendations from Bidell Equipment Inc for control of a Caterpillar 3412 TA LE gas engine driver, and an Arial JGJ-4 reciprocating compressor. The display/control/communications control module (Head) contains the processing power in the form of a single board computer with support board, Vacuum Fluorescent Display (VFD), (which is a dot matrix alpha-numeric display in a 4 line by 20 character format), and 16 button keypad. The VFD displays first-in shutdowns, an alarm history, sequencing messages, and all process real-time data. A separate pushbutton mounted on the side of the panel is provided for ESD (Emergency Shutdown). This document covers both the standard base system, and several options summarized in the next sections. 1.2 Standard Base System The base system control logic functionality is listed below. These are covered in greater detail in later sections. Lube oil pump control (prelube and postlube) Engine Startup Cooldown stop sequencing Compressor shutdown logic Low class P discharge logic Rod load calculations Speed control Bypass control Suction valve control 1.3 Optional Functionality The optional system control logic functions are listed below. These are covered in greater detail in later sections. References to these control options throughout the philosophy are only valid if the options have been selected. Blowdown valve control

6 Project: Stock Revision 1 Page 6 2. START-UP / SHUTDOWN SEQUENCING The setpoint, and timer parameters discussed in this section can be accessed from the setpoint screens. Please refer to the project IO list document for setpoint / timer values, and locations. The operator must ensure that all shutdowns have been cleared before a start can be attempted. This may be confirmed by viewing the Millennium display. Once all shutdowns have been cleared, a STANDBY message is displayed on the MAIN screen. The ESD relay will energize, all other relays will remain off (Blowdown will operate as required), and the Speed control will output the WARMUP RPM setting. The Bypass Valve output will be at 0%. If the Suction Valve control is in AUTO, the Suction Pressure will be maintained at the START PRS setting. If the control is in MAN, the operator can control the output using the MAN OUT setting. Table 2-1 describes the start-up sequencing in detail. Table 2-1: Start-Up Sequencing Item Step Description 1 Press RUN/STOP key. Initiates a start attempt. When the RUN/STOP button is pressed the Speed output is set to WARMUP RPM and the Bypass Valve will fully open to 0.0%. The Suction Valve output will be in control. Each step through the start sequence will be displayed on the HOME front display screen on the ST: status line. When a shutdown occurs the status will change to SHUTDOWN. The Event display will flash the Alarm Summary screen for details. 2 Prelube The Lube relay will energize and the PERMISS DLY timer will start. The controller will monitor both compressor and engine oil permissive settings. If the compressor permissive pressure is not reached at the expiration of the PERMISS DLY timer, the controller will signal COMP OIL PERM FAIL. The Lube relay will turn off, and the controller will wait for a RESET. The RUN/STOP button will have to be pushed to attempt another start. If the engine permissive pressure is not reached at the expiration of the PERMISS DLY timer, the controller will signal ENGINE OIL PERM FAIL. The Lube relay will turn off, and the controller will wait for a RESET. The RUN/STOP button will have to be pushed to attempt another start. When both permissives are met, the PERMISS DLY timer will zero, and the PRELUBE DLY timer will start. The unit will continue prelubing for the

7 Project: Stock Revision 1 Page 7 duration of the PRELUBE DLY timer. 3 Engine Start Following the completion of the PRELUBE DLY timer, the Lube relay will deenergize and the crank sequence will initiate. The Ignition and Crank relays will energize. If the engine RPM does not rise above 0 rpm at any time during the first crank attempt, the controller will assume a problem with the unit and a FAIL TO CRANK shutdown will occur. The CRANK DLY and PURGE DLY timers will start. The display will change to CRANKING. The Crank relay will remain on for the duration of the CRANK DLY or until the engine RPM rises above the CRANK DIS (crank disconnect) RPM. When the PURGE DLY expires, the Fuel Valve relay will energize. If the speed does not reach the CRANK DIS RPM before the CRANK DLY timer expires the Crank, Ignition, and Fuel Valve relays will deenergize and the REST DLY timer will start. The display will change to RESTING. When the REST DLY timer expires, the Crank and Ignition relays will energize, the Fuel Valve relay will energize after the PURGE DLY, and the crank attempt counter will increase by 1. If the engine does not start when the actual crank attempts is equal to the CRANK ATTEMPTS setpoint the controller will signal a FAIL TO START fault. This fault must be RESET, and a new start attempt made. NOTE: If the crank RPM falls below 50 rpm, after it has been above 50 RPM, the Crank relay will de-energize and the REST DLY timer will start. The display will change to RESTING. When the REST DLY timer expires the Crank relay will energize and the crank sequence will be repeated. 4 Warm-up When the engine RPM rises above the CRANK DIS RPM, the crank sequence will finish and the display will change to WARMUP. Automatic loading of the unit is not permitted until the system has warmed up. The internal Run Hours will begin accumulating. The Class B1 and B2 timers will begin counting. When the timers expire the Class B1 and B2 faults will be armed. The Status relay will energize at the expiration of the Class B1 timer. The WARMUP DLY timer is started. The Engine Jacket Water Temperature, and Compressor Oil Temperature permissives are monitored. After a 15 second delay the Suction Valve control setpoint will begin to ramp from the START PRS setting to the MAINT SUC setting (if the Suction Valve output is in AUTO) using the SUC STEP P, and ST RAMP TIME settings (adjustable from the SUCTION CNTL screen). If the engine RPM falls 50 RPM below the CRANK DIS RPM a LOSS OF SPEED SIGNAL fault will occur immediately. The UNDERSPEED shutdown (Class C) will be armed when the engine RPM rises above the UNDERSPEED setpoint. When the WARMUP DLY timer expires and the temperature permissives are met the display will change to READY TO LOAD. The Speed output will increase to the IDLE RPM using the speed control manual settings.

8 Project: Stock Revision 1 Page Compressor Cooldown Stop The unit can be loaded by changing the first line of the HOME front display to LOAD. If the HOME page is not displayed, the HOME key can be repeatedly pressed until the page appears. Pressing the RUN/STOP button of the Millennium controller initiates a cooldown stop sequence. The Bypass Valve will begin ramping to 0% using the manual open bypass settings. When the Bypass Valve position falls below the BYP P THR DWN (bypass position for throttle down) setting, the Speed control output will begin ramping the engine RPM to the Min RPM setting using the manual speed control settings. When the Bypass Valve is at 0% and the speed control is at Min RPM, the Speed control will decrease to the Warmup RPM setting. The status display will change to COOLDOWN. The COOLDOWN DLY timer will begin counting. The unit can be forced into an immediate stop by pressing the TIMER 0 key. When the COOLDOWN DLY timer expires: - The Fuel Valve relay will de-energize. - The IGN KILL DLY timer is started. - All Class B faults are locked out. - The internal Run Hours stop counting. - The Status relay will de-energize. - The Suction Pressure will be controlled to the START PRS setting. - When the IGN KILL DLY timer expires the Ignition relay will de-energize, and the Lube relay will energize for the duration of the POSTLUBE DLY. The display will change to POSTLUBING. - When the postlube cycle is complete, the display will change to STANDBY, and the unit will be ready for a start attempt. NOTE: If the unit is restarted while the unit is postlubing, the postlube sequence will stop and the start sequence will begin.

9 Project: Stock Revision 1 Page Alarm Stop (Optional) An ALARM STOP is initiated when a parameter reaches an alarm setpoint. The unit will complete a cooldown stop. The cooldown stop will help reduce engine maintenance, rather than an always initiating an immediate stoppage. The display will change to SHUTDOWN. The FAULT SNAPSHOT page will record the values of the process parameters. The 4-line fault message will appear in the display. The Bypass Valve will begin ramping to 0% using the manual bypass settings. When the Bypass Valve position falls below the BYP P THR DWN (bypass position for throttle down) setting, the Speed control output will begin reducing the engine RPM to the Min RPM setting using the manual speed control settings. When the Bypass Valve is at 0% and the Speed control is at Min RPM, the speed control will decrease to the WARMUP RPM setting. The COOLDOWN DLY timer will begin counting. The unit can be forced into an immediate stop by pressing the TIMER 0 key. When the COOLDOWN DLY expires: - The Fuel Valve relay will de-energize. - The IGN KILL DLY timer is started. - All Class B faults are locked out. - The internal Run Hours stop counting. - The Status relay will de-energize. - The Suction Valve will close completely (0%). - When the IGN KILL DLY timer expires the Ignition relay will de-energize, and the Lube relay will energize for the duration of the POSTLUBE DLY. The unit must be reset to change the status to STANDBY, to allow another start attempt. NOTE: If the unit is restarted while the unit is postlubing, the postlube sequence will stop and the start sequence will begin. The Alarm Stop option can be disabled by changing the COOLDOWN SELECT option to NO (N) on the MISC CAL setpoints screen.

10 Project: Stock Revision 1 Page Engine / Compressor Shutdown A SHUTDOWN is initiated if a discrete shutdown switch trips, an analog shutdown setpoint is exceeded, or an analog input sensor fails. This is deemed a point at which catastrophic damage can occur, and the unit must be stopped immediately. The display will change to SHUTDOWN. The FAULT SNAPSHOT page will record the values of the process parameters. The 4-line fault message will appear in the display. The Suction Valve and, Bypass Valve outputs will immediately ramp to 0%. The Speed output will ramp to the WARMUP RPM setting. When a shutdown occurs: - The Fuel Valve relay will de-energize. - The IGN KILL DLY timer is started. - All Class B faults are locked out. - The internal Run Hours stop counting. - The Status relay will de-energize. - The Suction Valve will close completely (0%). - When the IGN KILL DLY timer expires the Ignition relay will de-energize, and the Lube relay will energize for the duration of the POSTLUBE DLY. The unit must be reset to change the status to STANDBY, to allow another start attempt. When the unit is reset the Suction Valve will start controlling to the START PRS setting. NOTE: If the unit is restarted while the unit is postlubing, the postlube sequence will stop and the start sequence will begin. NOTE: If the fault condition is not cleared, and the RESET button is pushed the FAULT SNAPSHOT page will be overwritten. 2.4 Panel Emergency Shutdown (ESD) An ESD fault is initiated by pressing the ESD pushbutton mounted on the control panel, opening the Remote ESD discrete input contact, or through Modbus. When an ESD fault occurs: The Fuel and Ignition relays will de-energize. The Bypass valve will open. The Suction Valve will close completely (0%). The Blowdown valve will open to completely de-pressurize the unit The ESD relay will de-energize. No compressor postlube cycle is performed.

11 Project: Stock Revision 1 Page MANUAL LOADING CONTROL 3.1 Manual Bypass Valve Control Manual Bypass Valve control is only permitted when the unit has started, automatic loading control has been initiated, and the engine speed has exceeded the engine MIN RPM. When the unit is in the LOADED state, the Bypass Valve analog output can be placed in manual mode from the BYPASS CONTROL screen. In manual mode the operator can select the desired bypass position using the keypad and changing the MANUAL OUT setting. The output can only be changed between 0 and 100%. The Bypass Valve output will ramp to the entered value using the OPEN % or CLOSE % settings every second. If the AUTO/MAN button is toggled back and forth the MC controller will track the auto setting so a bumpless transfer will occur. The OPEN % and CLOSE % settings can be adjusted on the MANUAL CONTROL setpoint screen (Login Access Level 4). 3.2 Manual Speed Control The Speed analog output can be placed in manual mode from the SPEED CONTROL screen. In manual mode the operator can select the desired engine RPM using the keypad and changing the MANUAL OUT setting. The RPM can only be changed between the MIN RPM and MAX RPM settings. The Speed output will ramp to the value using the INC RPM or DEC RPM settings every second. If the AUTO/MAN button is toggled back and forth the MC controller will track the auto setting so a bumpless transfer will occur. The INC RPM and DEC RPM settings can be adjusted on the MANUAL CONTROL setpoint screen (Login Access Level 4). 3.3 Manual Suction Valve Control In manual mode the operator can select the desired Suction Valve position using the keypad and changing the MANUAL OUT setting from the SUCTION CONTROL screen. This is only permitted when the controller is not in a shutdown condition. The Suction Valve can only be changed between the 0 and 100%. The output will ramp to the entered value using the OPEN % or CLOSE % settings every second. The MC controller will track the auto setting so a bumpless transfer will occur. The Suction Valve control can be placed in AUTO/MAN independent of the speed/bypass control. The OPEN % and CLOSE % settings can be adjusted on the MANUAL CONTROL setpoint screen (Login Access Level 4).

12 Project: Stock Revision 1 Page AUTOMATIC LOADING CONTROL When a READY TO LOAD status is displayed the LOAD state can be selected. From the HOME screen the STATE line must be selected. Press the SETUP ENTER key. Press the UP ARROW key. This will change the STATE to LOAD. Press the SETUP ENTER key. The Speed control will ramp up to the engine MIN RPM. Once the speed reaches the MIN RPM, the Speed and Bypass outputs will be in Automatic control. 4.1 Automatic Speed Control The lowest output signal from either the Suction or Discharge Speed Control is sent to the Speed Control output Suction If the Suction Pressure is above the MAINT SUC + SUC PRS DB (deadband), the Speed control will increase by the INC RPM value at the UPDATE(ms) rate in an attempt to reduce the pressure. If the Suction Pressure is below the MAINT SUC - SUC PRS DB, the Speed control will decrease by the DEC RPM value at the UPDATE(ms) rate in an attempt to increase the pressure. When the Suction Pressure is within the deadband of the pressure setpoint no output change will occur. The SUC PRS DB, INC RPM, DEC RPM (Login Access Level 4), and UPDATE(ms) (Login Access Level 3) parameters can be adjusted from the SPD CTRL-SUC setpoint screen. The current Auto Mode (SUCTION/DISCHARGE) is also displayed on this screen. The MAINT SUC setting can be adjusted from the SPEED CONTROL front display screen (Login Access Level 5) Discharge If the Discharge Pressure is above the MAINT DIS + DIS PRS DB (deadband), the Speed control will decrease by the DEC RPM value at the UPDATE(ms) rate in an attempt to reduce the pressure. If the Discharge Pressure is below the MAINT DIS DIS PRS DB, the Speed control will increase by the INC RPM value at the UPDATE(ms) rate in an attempt to increase the pressure. When the Discharge Pressure is within the deadband of the pressure setpoint no output change will occur.

13 Project: Stock Revision 1 Page 13 The DIS PRS DB, INC RPM, DEC RPM (Login Access Level 4), and UPDATE(ms) (Login Access Level 3) parameters can be adjusted from the SPD CTRL-DIS setpoint screen. The current Auto Mode (SUCTION/DISCHARGE) is also displayed on this screen. The MAINT DIS setting can be adjusted from the SPEED CONTROL front display screen (Login Access Level 5). 4.2 Automatic Bypass Valve Control The lowest output signal from either the Suction or Discharge Bypass PID is sent to the Bypass Control output Suction If the Suction Pressure is above the MAINT SUC + SUC PRS DB (deadband), the Bypass control will increase (closing valve) in an attempt to reduce the pressure. If the Suction Pressure is below the MAINT SUC - SUC PRS DB, the Bypass control will decrease (opening valve). When the Suction Pressure is within the deadband of the pressure setpoint no output change will occur. The MAINT SUC setting can be adjusted from the BYPASS CONTROL front display screen (Login Access Level 5). The BYP CTRL-SUC setpoint screen contains the following parameters and displays: SUC PRS DB: Deadband - No output change when pressure is within the range of MAINT SUC +/- SUC PRS DB. (Login Access Level 4) PROP COEF: Proportional Coefficient * (Login Access Level 3) INT COEF: Integral Coefficient * (Login Access Level 3) DERV COEF: Derivative Coefficient * (Login Access Level 3) PID UPDATE(ms): Update * - (Login Access Level 3) P I D Display of the Proportional / Integral / Derivative weights. E LE Display of the PID error / Last PID error. BYPASS OUT: Display of Bypass output percentage. S1 SUC PRS: Display of the current Suction Pressure. AUTO MODE: Display of the current loop in control of the valve (Suction/Discharge). * Refer to Appendix B for detailed descriptions.

14 Project: Stock Revision 1 Page Gain Multiplier If the Suction Pressure falls below the SUC BYP THR (suction bypass threshold) setting it may be due to a condition where the Bypass Valve cannot react fast enough to avoid a low-pressure shutdown ( pigging for example). An additional gain multiplier (BYP GAIN MULT) is used to open the valve faster when the pressure is below this threshold. The SUC BYP THR, and BYP GAIN MULT settings can be adjusted from the MISC SETTINGS setpoint screen (Login Access Level 3) Discharge If the Discharge Pressure rises above the MAINT DISC + DIS PRS DB, the Bypass control will decrease (opening valve) in an attempt to reduce the pressure. If the Discharge Pressure is below the MAINT DIS - DIS PRS DB, the Bypass control will increase (closing valve). When the Discharge Pressure is within the deadband of the pressure setpoint no output change will occur. The MAINT DIS setting can be adjusted from the BYPASS CONTROL front display screen (Login Access Level 5). The BYP CTRL-DIS setpoint screen contains the following parameters and displays: DIS PRS DB: Deadband - No output change when pressure is within the range of MAINT DIS +/- DIS PRS DB. (Login Access Level 4) PROP COEF: Proportional Coefficient * (Login Access Level 3) INT COEF: Integral Coefficient * (Login Access Level 3) DERV COEF: Derivative Coefficient * (Login Access Level 3) PID UPDATE(ms): Update * - (Login Access Level 3) P I D Display of the Proportional / Integral / Derivative weights. E LE Display of the PID error / Last PID error. BYPASS OUT: Display of Bypass output percentage. DIS PRS: Display of the current Discharge Pressure. AUTO MODE: Display of the current loop in control of the valve (Suction/Discharge). * Refer to Appendix B for detailed descriptions.

15 Project: Stock Revision 1 Page Automatic Suction Control The MC controller will control the Suction Valve output based on a pressure setpoint. If the suction pressure is above the setpoint, the valve will close. If the suction pressure is below the setpoint, the valve will open. When the Suction Pressure is within the deadband of the pressure setpoint, no output change will occur. When the unit is in AUTO and at a STANDBY condition, the Suction Pressure will be controlled to the START PRS setting. This setting is lower than the normal loaded Suction Pressure. This will ensure that a minimum load is applied during the engine start sequence. Fifteen seconds after the CRANK DIS RPM has been reached, the Suction Pressure setpoint will start ramping to the MAINT SUC setpoint using two settings: suction step pressure (SUC STEP P) and start ramp time (ST RAMP TIME). The suction step pressure is the amount of pressure increase that will be added to the current suction pressure setpoint. This increase will occur every time the start ramp time expires. The pressure will be controlled to the MAINT SUC PRS until the unit is stopped manually or a shutdown occurs. When a shutdown occurs the Suction Valve will close completely to 0%, until the condition is reset. The control will then restart using the START PRS setting. The MAINT SUC, and START PRS settings can be adjusted from the SUCTION CONTROL front display screen (Login Access Level 5). The SUCTION CNTL setpoint screen contains the following parameters, and displays: SUC PRS DB: Deadband - No output change when pressure is within the range of MAINT SUC +/- SUC PRS DB. (Login Access Level 4) PROP COEF: Proportional Coefficient * (Login Access Level 3) INT COEF: Integral Coefficient * (Login Access Level 3) DERV COEF: Derivative Coefficient * (Login Access Level 3) PID UPDATE(ms): Update * - (Login Access Level 3) P I D Display of the Proportional / Integral / Derivative weights. E LE Display of the PID error / Last PID error. SUCTION OUT: Display of Suction output percentage. S1 SUC PRS: Display of the current Suction Pressure. SUC STEP P: Setpoint ramp step size. (Login Access Level 3) ST RAMP TIME: Time between setpoint ramp steps. (Login Access Level 3) * Refer to Appendix B for detailed descriptions.

16 Project: Stock Revision 1 Page Controlled Unload A controlled unload can be initiated from the Home front display screen. The Bypass Valve will start ramping open to 0% using the manual output settings. The Speed control will remain in its current position until the Bypass Valve is open to the BYP P THR DWN position (bypass position for throttle down). The Speed control will then start decreasing to MIN RPM using the manual DEC RPM settings. When the Bypass Valve is at 0% and the Speed output is at MIN RPM, the Speed output will be reduced to the IDLE RPM. The unit will run in this position until a reload, or a stop is initiated. When a stop is requested, the controller will reduce the RPM to the Warmup RPM setting. The Cooldown Timer will start and the controller will initiate a stop after the timer expires. The BYP P THR DWN setting can be adjusted from the MISC SETTINGS setpoint screen (Login Access Level 3). 4.5 Blowdown Valve Control The MC controller is equipped with automatic blowdown logic. If the Suction Pressure is above the BD VLV OPEN setpoint, the Blowdown Valve output will deenergize to open the valve, and reduce the pressure. When the Suction Pressure falls below the BD VLV CLS setpoint the Blowdown Valve output will energize to close the valve. The logic is only active when the MC is in the STANDBY or SHUTDOWN condition. If the unit is started while in the BLOWDOWN state, the relay will energize, and the start sequence will begin. The BD VLV OPEN/CLS settings can be adjusted from the MISC SETTINGS setpoint screen (Login Access Level 3). 5. COMPRESSOR ROD LOAD CALCUATIONS Compressor stage differential pressure alarm/shutdown calculations are based on the specific cylinder characteristic curves. The rod-loading calculations are based on the compressor suction and discharge pressures, in conjunction with a Rod-Loading formula. When doing calculations for stage 2, and stage 3 (as applicable) the previous stages discharge value will be used as the setpoint value for PS.

17 Project: Stock Revision 1 Page LOW CLASS P DISCHARGE LOGIC Low class P discharge logic is provided for each compressor discharge stage. A CLASS P Timer will start once the Bypass Valve reaches the BYP POS P LK preset position. The Class P functions are armed once the CLASS P Timer expires. The shutdown will disarm when the Bypass Valve position falls below the BYP POS P LK preset position. The CLASS P Timer, and BYP POS P LK setting can be adjusted from the TIMERS setpoint screen (Login Access Level 3).

18 Project: Stock Revision 1 Page MISCELLANEOUS 7.1 Password Protection The parameters that are adjustable from the screens are grouped into different access levels. A login code is required to access each level. Login level (5) is the default level. The Login entry is located in the SETUP MENU screen. To Login with a higherlevel code, the cursor must be placed on the Login line, and then the SETUP ENTER key must be pressed. The cursor will move over the zero displayed on the right side of that line. A level pass-code can now be entered. There are four access levels ranging from level (4), the lowest privilege level up to level (1), the highest privilege level. Level (1) - called the Administrator level. Complete access. The Project, and or Application can be deleted, outputs can be forced off and on, a Remote Debugger can be run, the administrator menu is available, and the real time clock can be set. Level (2) access to input calibrations, and SERVICE MODE forcing of outputs. Level (3) access to settings that could cause improper operation of the machine. Level (4) - access to settings that will not cause improper operation of the machinery. All login levels have a common timer that starts to count down after each key press. If there are no key presses for the length of the Inactive/AutoLogout Delay, then the Login level will revert to the base Login level (5).

19 Project: Stock Revision 1 Page Verify Discrete Input / Outputs The open (0) or closed (X) status of each discrete input, and the off (0) or on (X) status of each discrete output can be viewed from the HMI INPUTS front display screen. 7.3 Service Mode The unit is equipped with a SERVICE MODE. The technician can use this mode to force relay outputs and analog outputs to ensure proper operation of connected devices. When the unit is in a STANDBY or SHUTDOWN state press the FN key, confirm Fn Key Activated is displayed, and then press the TEST key. When the timeout expires the unit will switch back to STANDBY or SHUTDOWN mode. All relay outputs will turn off when in the SERVICE MODE. When the service mode is exited normal panel operation will start. Login level (2) is required to enter this mode. Note: The ESD relay will be de-energized when in the SERVICE MODE. 7.4 Test Mode The unit is equipped with a TEST mode for testing discrete input functionality. Analog values are not normally tested, due to the ability to read the actual value of the parameter. Pressing the TEST key activates the TEST mode. The preferred display page is D-3 as the test timer and status can be observed. When a switch is faulted, a 4-line alarm message will appear. No parameters are logged in the snapshot page or the EVENT history. 7.5 Run Time Hours The engine Run Time Hours can be viewed from the HMI HOME screen. Run Time Hours can be reset on the RPM SETTINGS setpoint screen. 7.6 Speed Output Actuator Adjustments The THR OUT MIN, and THR OUT MAX settings can be used to match the controller output to the resulting engine speed. The THR OUT MIN is the RPM value when 4mA is applied, and the THR OUT MAX is the RPM value when 20mA is applied. Some extrapolation may be required if 4mA is lower than the actual minimum speed output, or if maximum speed is achieved with less than 20mA. The THR OUT MIN, and THR OUT MAX settings can be adjusted from the MISC CAL setpoint screen (Login Access Level 2).

20 Project: Stock Revision 1 Page MODBUS COMMUNICATIONS This panel will be provided with MODBUS functionality. The following points will be available for read-only access: All Analog Input Readings All Analog Output Values (percent) Speed Output (RPM) Reading All Thermocouple Input Readings All Discrete Input Open/Closed Status All Discrete Output On/Off Status Engine Run Time Hours Alarm and Shutdown Event Codes The following points will be available for read/write access: Remote Start Remote Stop Remote Reset Remote Engine Maximum Load Speed Setpoint Remote PID Control Setpoints Load / Unload Alarm / Shutdown setpoints Note: A complete address list will be provided in the Event List and Modbus Map document for this project. 8.1 Local / Remote Mode The Local and Remote Stop, Start and Reset commands are active at all times.

21 Project: Stock Revision 1 Page 21 APPENDIX A Input/Output List See project I/O list provided separately. APPENDIX B Definitions Table B-1: Alarm/Shutdown Classification, and PID Definitions Class Class A Class B1 Class B2 Class C Class P Prop Coef Int Coef Derv Coef PID Update (ms) Description Class A alarm/shutdown functions are always enabled. All Class A shutdowns must be cleared before the unit can be started. Examples: Engine Oil Level, Cylinder Discharge Temperature Class B1 alarm/shutdown functions are disabled until the B1 Timer expires. Examples: Low Comp Oil Pressure Class B2 alarm/shutdown functions are disabled until the B2 Timer expires. Examples: Compressor Rod Reversal Class C alarm/shutdown functions are disabled until the unit is running. Class C functions are then individually monitored. When a Class C function becomes healthy it is enabled, and will cause an alarm/shutdown if it then goes unhealthy. Class P alarm/shutdown are armed once the bypass valve reaches a preset position and a P timer expires. The shutdown will disarm when the bypass valve position falls below the preset position. The Proportional coefficient for the PID loop. This is a multiplier for the error (PV minus setpoint) and will determine how the error will directly affect the amount of change in output. Too low a number here will result in sluggish action of the PID loop. Too high a number here will result in overshoot and oscillation of the PID loop. The Integral coefficient for the PID loop. This is a multiplier for the amount of time the error (PV minus setpoint) has been above or below setpoint. The more time that passes before the loop reaches its setpoint, will directly affect the amount of change in output. Use this number to balance out overshoot caused by the Proportional part of the PID loop. Too low a number here will take out the Integral part of control of the PID loop. Too high a number here will result in oscillation of the PID loop. The Derivative coefficient for the PID loop. This is a multiplier for how fast the error (PV minus setpoint) is changing. The faster the PV or setpoint changes will directly affect the amount of change in output. Use this number to catch spikes in pressure. Too low a number here will take out the Derivative part of control of the PID loop. Too high a number here will result in oscillation of the PID loop. Set the delay in milliseconds for the PID loop calculation to allow the PV readings to update and stabilize to the changing conditions caused by the PID loop. Too fast an update time will result in oscillation of the PID loop. Too slow an update time will result in a sluggish PID loop.

22 Project: Stock Revision 1 Page 22 PLEASE APPROVE AND RETURN. Comments: Approved by: Approval date: END DOCUMENT

Reciprocating Equipment Manager Operations Manual AIR / FUEL RATIO AND GOVERNOR CONTROL

Reciprocating Equipment Manager Operations Manual AIR / FUEL RATIO AND GOVERNOR CONTROL REMVue Reciprocating Equipment Manager Operations Manual AIR / FUEL RATIO AND GOVERNOR CONTROL REMVue 500/AS OPERATIONS MANUAL Version 3 April 16, 2007 DISCLAIMER This document is designed to provide information

More information

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING AUGUST, 2004 REV.A CURTIS TOLEDO OPERATOR S MANUAL SUPPLEMENT AF Series Compressors VS models with VFD WARNING Personal injury and/or equipment damage will result by failing to pay attention to the vital

More information

MATRIX LLC LEVEL CONTROL PANEL

MATRIX LLC LEVEL CONTROL PANEL MATRIX LLC LEVEL CONTROL PANEL Installation Operation Maintenance Manual 1-26-09 REV-0.3 1 INDEX Introduction. 3 Product Configurations..... 4 I/O Descriptions. 8 Operation o Intercooler, Accumulator,

More information

Hitachi Screw Point List and Startup Sequence

Hitachi Screw Point List and Startup Sequence Micro Control Systems APPLICATION NOTE APP-008 Hitachi Screw Point List and Startup Sequence Revision History Date Author Description 1/16/98 RCT Initial App note (draft copy) 3/12/98 RCT Released 3/13/98

More information

MAGPOWR Spyder-Plus-S1 Tension Control

MAGPOWR Spyder-Plus-S1 Tension Control MAGPOWR TENSION CONTROL MAGPOWR Spyder-Plus-S1 Tension Control Instruction Manual Figure 1 EN MI 850A351 1 A COPYRIGHT All of the information herein is the exclusive proprietary property of Maxcess International,

More information

Product Manual (Revision A, 8/2015) Original Instructions. ProAct II Digital Speed Control System. Technical Supplement

Product Manual (Revision A, 8/2015) Original Instructions. ProAct II Digital Speed Control System. Technical Supplement Product Manual 36060 (Revision A, 8/2015) Original Instructions ProAct II Digital Speed Control System Technical Supplement DEFINITIONS This is the safety alert symbol. It is used to alert you to potential

More information

Flight Systems. Replacement for KASSEC DESCRIPTION

Flight Systems.   Replacement for KASSEC DESCRIPTION DESCRIPTION The is a universal generator controller that will start, stop, and provide engine protection for most generators. Universal replacement for both the 90353 and 90354 KASSEC Compatible with most

More information

MODEL MCL-3212 SPEEDOMETER/TACHOMETER for 2012 up Dyna and Softail with 4 gauge

MODEL MCL-3212 SPEEDOMETER/TACHOMETER for 2012 up Dyna and Softail with 4 gauge MODEL MCL-3212 SPEEDOMETER/TACHOMETER for 2012 up Dyna and Softail with 4 gauge IMPORTANT NOTE! This gauge has an odometer preset option that is only available one time in the first 100 miles (160km) of

More information

Vission 20/20 micro-controller. Operation and service manual

Vission 20/20 micro-controller. Operation and service manual Vission 20/20 micro-controller Operation and service manual Section Title Table of Contents Section Number How To Use This Manual...TOC-8 Section 1 Operational Flow Charts Requirements to Start Compressor...1-1

More information

Supersedes CL2 (512) Form CL2 (615) STARTUP CHECKLIST PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT NO:

Supersedes CL2 (512) Form CL2 (615) STARTUP CHECKLIST PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT NO: YMC 2 - MOD A STARTUP CHECKLIST Supersedes 160.78-CL2 (512) Form 160.78-CL2 (615) STARTUP CHECKLIST CUSTOMER: JOB NAME: ADDRESS: LOCATION: PHONE: CUSTOMER ORDER NO: JCI TEL NO: JCI ORDER NO: JCI CONTRACT

More information

Control Panel. Operation and Service Manual

Control Panel. Operation and Service Manual Control Panel Operation and Service Manual 1 2 Important Note Before applying power to the control panel, all wiring to the panel should be per NEC. Specifically check for proper voltage and that the neutral

More information

MODEL MCL /8 SPEEDOMETER/TACHOMETER for 2004 up

MODEL MCL /8 SPEEDOMETER/TACHOMETER for 2004 up MODEL MCL-3204 3-3/8 SPEEDOMETER/TACHOMETER for 2004 up IMPORTANT NOTE! This gauge has an odometer preset option that is only available one time in the first 100 miles (160km) of operation. See Odometer

More information

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list OPERATOR'S MANUAL Automatic Genset Controller, AGC-4 Display readings Push-button functions handling Log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com

More information

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951

More information

Setup Tabs. Basic Setup: Advanced Setup:

Setup Tabs. Basic Setup: Advanced Setup: Setup Tabs Basic Setup: Password This option sets a password that MUST be entered to re-enter the system. Note: ProEFI can NOT get you into the calibration if you lose this password. You will have to reflash

More information

CPW Current Programmed Winder for the 890. Application Handbook. Copyright 2005 by Parker SSD Drives, Inc.

CPW Current Programmed Winder for the 890. Application Handbook. Copyright 2005 by Parker SSD Drives, Inc. CPW Current Programmed Winder for the 890. Application Handbook Copyright 2005 by Parker SSD Drives, Inc. All rights strictly reserved. No part of this document may be stored in a retrieval system, or

More information

FRICK QUANTUM HD COMPRESSOR CONTROL PANEL

FRICK QUANTUM HD COMPRESSOR CONTROL PANEL Operation Form 090.040-O (AUG 2014) File: SERVICE MANUAL - Section 90 Replaces: 090.040-O (JUNE 2013) Dist: 3, 3a, 3b, 3c FRICK QUANTUM HD COMPRESSOR CONTROL PANEL Version 10.16 CURRENT DESIGN AUGUST 2014

More information

Be2K-Plus AMF panel control wiring --

Be2K-Plus AMF panel control wiring -- Be2K-Plus OEM's Manual V200 - August - 014 page 1 Be2K-Plus AMF panel control wiring -- Consult Section 17.0 for software upgrades & revisions The information in this document may be subject to change

More information

Generator Sets Controller 210. Operation Manual. Ver1.0

Generator Sets Controller 210. Operation Manual. Ver1.0 Generator Sets Controller 210 Operation Manual Ver1.0 Note This information could include technical inaccuracies or typographical error. Manufacturer may make improvements and/or changes in the product(s)

More information

PowerCommand 2100 digital generator set control

PowerCommand 2100 digital generator set control Specification sheet PowerCommand 2100 digital generator set control Description The PowerCommand 2100 control is a microprocessor-based generator set monitoring, metering and control system. The control

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated DC-4 SEQUENCE OVERFIRE DRAFT CONTROL SYSTEM OPERATING AND MAINTENANCE MANUAL THE POWER TO MANAGE ENERGY 2001 South 21 st Street, Parsons, Kansas 67357 Telephone 620-421-0480, Fax

More information

MPC-20 Engine Controller Operations Manual

MPC-20 Engine Controller Operations Manual Software Release 2.8.10043 MPC-20 Engine Controller Operations Manual *Approved by CSA for non-hazardous locations (Group Safety Publication EIC 61010-1) Products covered in this document comply with European

More information

Application Note. First trip test. A circuit breaker spends most of its lifetime conducting current without any

Application Note. First trip test. A circuit breaker spends most of its lifetime conducting current without any Application Note First trip test A circuit breaker spends most of its lifetime conducting current without any operation. Once the protective relay detects a problem, the breaker that was idle for maybe

More information

DSEULTRA DSE6000 Quick Start Guide Document Number

DSEULTRA DSE6000 Quick Start Guide Document Number n DSEULTRA DSE6000 Quick Start Guide Document Number 057-102 Author : John Ruddock Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723 890099 Sales

More information

Alternative Fuel Engine Control Unit

Alternative Fuel Engine Control Unit 1999 Chevrolet/Geo Cavalier (CNG) Alternative Fuel Engine Control Unit Table 1: AF ECU Function Parameters The (AF ECU) controls alternative fuel engine operation. The control unit monitors various engine

More information

Overvoltage Suppression F7 Drive Software Technical Manual

Overvoltage Suppression F7 Drive Software Technical Manual Overvoltage Suppression F7 Drive Software Technical Manual Software Number: VSF11015X, Drive Models: CIMR-F7UXXXXXX-062, CIMR-F7U40750F-145. Document Number: TM.F7SW.062, Date: 09/17/2010, Rev: 10-09 This

More information

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II Document No.: LMSII_V100_OM Page 1 of 8 LMS II Document No.: LMSII_V100_OM Page 2 of 8 1. Operation: When the wet well level rises above the on level set point, the lead pump will start after an adjustable

More information

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL SMARTGEN ELECTRONICS Smartgen Electronic Equipment Co., Ltd No.12 Dongqing Street Zhengzhou Henan Province P.R.China Tel : (0086)-371-67992951

More information

Vission 20/20 micro-controller. Operation and service manual Version 2.6

Vission 20/20 micro-controller. Operation and service manual Version 2.6 Vission 20/20 micro-controller Operation and service manual Version 2.6 Important Message READ CAREFULLY BEFORE OPERATING YOUR COMPRESSOR. The following instructions have been prepared to assist in operation

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc

More information

Paralleling Equipment

Paralleling Equipment Paralleling Equipment PowerCommand Model 300 Digital Master Control Description The PowerCommand TM Digital MasterControl is a microprocessor-based paralleling system component, designed to directly interface

More information

MPC-10 Engine Controller Operations Manual

MPC-10 Engine Controller Operations Manual MPC-10 Engine Controller Operations Manual To see this manual in Spanish, German, French or Italian, please go to www.fwmurphy.com/mpc10 Software Release 2.08.10073.00 *Approved by CSA for non-hazardous

More information

TYPICAL CONFIGURATIONS SD700 Pump Control Macro single VSD with Jockey Pump

TYPICAL CONFIGURATIONS SD700 Pump Control Macro single VSD with Jockey Pump Pump Control Macro single VSD with Jockey Pump Created: M.Duncan Reviewed: B.Sheridan Position: Sales & Marketing Director Position: Technical Director Date: 17/06/09 Date: 19/06/09 1 Pump control macro

More information

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75 Cascade CD101 Auto-Start Controller Installation and Operations Manual 00-02-0594 2018-02-15 Sections 40 & 75 In order to consistently bring you the highest quality, full featured products, we reserve

More information

KELSEY CENTRIFUGAL JIG (KCJ) PILOT PLANT FUNCTIONAL SPECIFICATION

KELSEY CENTRIFUGAL JIG (KCJ) PILOT PLANT FUNCTIONAL SPECIFICATION KELSEY CENTRIFUGAL JIG (KCJ) PILOT PLANT FUNCTIONAL SPECIFICATION MT Project Number: 82040 Revision Date Revision Description BY APPROVED A 04/08/09 Issued for Internal Review TJ AF B 05/03/10 Revised

More information

PowerView PV380-R2 Mechanical Configuration

PowerView PV380-R2 Mechanical Configuration PowerView PV380-R2 Mechanical Configuration Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical safety directive

More information

CALIBRATION PROCEDURE FOR THE ALLEN-BRADLEY PLC TEMPERATURE CONTROLLER:

CALIBRATION PROCEDURE FOR THE ALLEN-BRADLEY PLC TEMPERATURE CONTROLLER: CALIBRATION PROCEDURE FOR THE ALLEN-BRADLEY PLC TEMPERATURE CONTROLLER: Note: The following procedure utilizes an Omega Model CL23A Digital Calibrator/Thermometer. If an equivalent calibrator/thermometer

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

Te 803 Electronic Controller. Service, Operation & Technical Information Manual Te 803 Electronic Controller Service, Operation & Technical Information Manual WARNING! Technical descriptions and data given in this document are accurate, to the best of our knowledge, but can be subject

More information

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,

More information

ICL Three Pump Controller

ICL Three Pump Controller ICL Three Pump Controller Pump Operation The number of pumps that the program controls can be selected by enabling only the ones that are currently installed and in service. The enable/disable setting

More information

REV 1.7 PROFIRE 2100 MANUAL BURNER MANAGEMENT SYSTEM

REV 1.7 PROFIRE 2100 MANUAL BURNER MANAGEMENT SYSTEM REV 1.7 PROFIRE 2100 MANUAL BURNER MANAGEMENT SYSTEM WARNING THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS 1, DIVISION 2, GROUPS ABCD OR NON-HAZARDOUS LOCATIONS ONLY. WARNING: EXPLOSION HAZARD DO NOT DISCONNECT

More information

CENTRIFEEDER ELECTRONICS

CENTRIFEEDER ELECTRONICS CENTRIFEEDER ELECTRONICS FOR USE WITH CENTRIFEEDER with Integrated Vibratory Control REV 08/13 ADDENDUM VERSION 6.22 SOFTWARE Copyright 2011 Eastern Instrument Laboratories, Inc. All Rights Reserved. TABLE

More information

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION... CONTENT 1. SUMMARY...4 2. PERFORMANCE AND CHARACTERISTICS...4 3. SPECIFICATION...5 4. OPERATION...6 4.1. DISPLAY PANEL...6 4.2. LCD ICON INSTRUCTION...7 4.3. DISPLAY INSTRUCTIONS...7 4.4. DISPLAY DESCRIPTION...8

More information

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016 PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS v1.1 Revised Table of Contents 1 Common Alarms and Warnings... 1 2 Common Issues... 6 2.1 Communication problems... 6 2.1.1 Controller communication

More information

Pacesetter. Pacesetter Plus. Installation and Operations Manual

Pacesetter. Pacesetter Plus. Installation and Operations Manual Pacesetter Pacesetter Plus Installation and Operations Manual v1.7.x 10/10/2014 Modbus is a trademark of Modicon Inc. Pacesetter/ Pacesetter Plus Installation and Operations Manual Copyright 2014 Extreme

More information

Issue 2.0 December EPAS Midi User Manual EPAS35

Issue 2.0 December EPAS Midi User Manual EPAS35 Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started

More information

TG350 User Manual. Manual Revision: Min. FW Revision: Date Released: 09/01/ DYNAGEN Technologies Inc

TG350 User Manual. Manual Revision: Min. FW Revision: Date Released: 09/01/ DYNAGEN Technologies Inc TG350 User Manual Manual Revision: 1.4.0 Min. FW Revision: 1.42.01 Date Released: 09/01/2014 Table of Contents 1 Introduction 1.1 Specifications... 3 2 Installation 2.1 Terminal s... 6 2.2 Typical Wiring...

More information

Murphy PowerCore MPC-20-R2 Engine Controller Operations Manual

Murphy PowerCore MPC-20-R2 Engine Controller Operations Manual Murphy PowerCore MPC-20-R2 Engine Controller Operations Manual *Approved by CSA for non-hazardous locations (Group Safety Publication EIC 61010-1, Third Edition) Products covered in this document comply

More information

INSTRUCTIONS FOR INSTALLING AND OPERATING THE UNIVERSAL AUTOSYNC MODEL ASPSS DUAL COMPRESSOR SEQUENCER CONSOLE S/N 1638 AND ABOVE

INSTRUCTIONS FOR INSTALLING AND OPERATING THE UNIVERSAL AUTOSYNC MODEL ASPSS DUAL COMPRESSOR SEQUENCER CONSOLE S/N 1638 AND ABOVE COMPRESSOR 1 EMERGENCY SHUTDOWN OFF POWER ON COMP LOADED COM PRESSOR OPERATING HOURS SYSTEM PRESSURE COMPRESSOR 2 EMERGENCY SHUTDOWN OFF POWER ON COMP LOADED COM PRESSOR OPERATING HOURS LEAD/LAG CONTROL

More information

Rev. 12/14/2001. PC-5500 PC-5750 Operation Manual

Rev. 12/14/2001. PC-5500 PC-5750 Operation Manual Rev. 12/14/2001 PC-5500 PC-5750 Operation Manual Operation Configuration Troubleshooting PC-5500 PC-5750 Custom Control Systems Inc. 2007 Beech Grove Place Utica, NY 13501 (315) 732-1990 www.customcontrolsystems.com

More information

INSTALLATION AND OPERATIONS MANUAL VERSION 3.1.2

INSTALLATION AND OPERATIONS MANUAL VERSION 3.1.2 INSTALLATION AND OPERATIONS MANUAL VERSION 3.1.2 This Manual is the intellectual property of Case Engineering inc. and is protected by U.S Copyright laws. You may not reproduce or alter this manual in

More information

Deep Sea Electronics Plc

Deep Sea Electronics Plc Deep Sea Electronics Plc 5120 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL Author: Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH England Tel: +44 (0) 1723

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5110 AUTOSTART CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44

More information

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951/67992952

More information

Water Specialist PR Control Valve Programming and Cover Drawing Manual

Water Specialist PR Control Valve Programming and Cover Drawing Manual Water Specialist PR Control Valve Programming and Cover Drawing Manual Page 2 PR Man u al PR Manual Page 3 Table of Contents PR Front Cover and Drive Assembly...4 OEM General Programming Instructions...5

More information

Be-K3 OEM s Manual --

Be-K3 OEM s Manual -- Be-K3 OEM's Manual V200 - July - 010 page 1 Be-K3 OEM s Manual -- Consult Section 17.0 for software upgrades & revisions The information in this document may be subject to change without notice. No part

More information

QUICK INSTALLATION GUIDE

QUICK INSTALLATION GUIDE MANUAL/AUTOMATIC T R A N S M I S S I O N 2 - B U T T O N R E M O T E S T A R T E R W I T H V I R T U A L T A C H S Y S T E M ( A S P R G - 1 0 0 0 C O M P A T I B L E ) QUICK INSTALLATION GUIDE Manual

More information

Dynamic Adjustment Procedure for 700-series Digital Controls. Application Note (Revision A,8/1998) Original Instructions

Dynamic Adjustment Procedure for 700-series Digital Controls. Application Note (Revision A,8/1998) Original Instructions Application Note 01304 (Revision A,8/1998) Original Instructions Dynamic Adjustment Procedure for 700-series Digital Controls (700, 701, 701A, 702, 705, 721, 723, 723PLUS, 828) General Precautions Read

More information

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599

More information

PowerCore MPC-10 Engine Controller & TEC-10 Panel Operations Manual

PowerCore MPC-10 Engine Controller & TEC-10 Panel Operations Manual PowerCore MPC-10 Engine Controller & TEC-10 Panel Operations Manual To see this manual in Spanish, German, French or Italian, please go to www.fwmurphy.com/mpc-10 www.fwmurphy.com/tec-10 In order to consistently

More information

Loadcell Tension Control

Loadcell Tension Control CORTEX INDUSTRIAL SYSTEM CONTROLLER Loadcell Tension Control Instruction Manual Model CORTEX-D00 Table of Contents 1. General Description... 2 2. Specifications... 3 2.1 Electrical... 3 2.2 Physical...

More information

DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual

DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual Document Number 057-152 Author : Paul Gibbons DSE3210 Configuration Suite Software Manual Issue 1 DSE3210 Configuration Suite Software

More information

TRIPS AND FAULT FINDING

TRIPS AND FAULT FINDING WWW.SDS.LTD.UK 0117 9381800 Trips and Fault Finding Chapter 6 6-1 TRIPS AND FAULT FINDING Trips What Happens when a Trip Occurs When a trip occurs, the drive s power stage is immediately disabled causing

More information

ANALOG CONTROL PANEL

ANALOG CONTROL PANEL ANALOG CONTROL PANEL 1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz. 3. Percent of Load: Displays percentage of load on the generator.

More information

Quick Start Guide TS 910

Quick Start Guide TS 910 Quick Start Guide TS 910 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer is responsible

More information

SmartPak Welding Controller WK-MPS-16 Constant Current

SmartPak Welding Controller WK-MPS-16 Constant Current SmartPak Welding Controller WK-MPS-16 Constant Current Features Latest state of the art ATMEL 8 bit microprocessor technology Synchronous digital welding control allows absolute precision Up to16 programmers

More information

ALiEn 2 ALiEn 2 Expert. Installation and Operations Manual

ALiEn 2 ALiEn 2 Expert. Installation and Operations Manual ALiEn 2 ALiEn 2 Expert Installation and Operations Manual v2.0.x 08/02/2016 Modbus is a trademark of Modicon Inc. ALiEn 2 /ALiEn 2 Expert Installation and Operations Manual Copyright 2016 Extreme Telematics

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE REV. ARS. WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This device may not cause

More information

FLY BY WIRE SETTINGS 31 August 2016

FLY BY WIRE SETTINGS 31 August 2016 FLY BY WIRE SETTINGS: Entries in red, except for charts (18 September 2014) GROUPS/OUTPUT FUNCTIONS/FBW: FBW Enabled: ENABLED FBW Control Frequency: 5000Hz (13Hz to 10000Hz) FBW Control Minimum Duty: -100%

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS www.altronicinc.com OPERATING INSTRUCTIONS DEVIATION FROM THESE INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE WARNING: PERSONAL INJURY TO OPERATORS OR OTHER NEARBY PERSONNEL. HYPERFUEL

More information

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic Smartgen Electronic Equipment Co., Ltd No.28 Jinsuo Road Zhengzhou Henan Province P.R.China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951/67992952

More information

DEEP SEA ELECTRONICS

DEEP SEA ELECTRONICS DEEP SEA ELECTRONICS DSE6010 MKII / DSE6020 MKII Configuration Suite PC Software Manual Document Number: 057-223 Author: Fady Atallah DSE6010 MKII / DSE6020 MKII Configuration Suite PC Software Manual

More information

PCT-3001 plus. Display LCD

PCT-3001 plus. Display LCD PCT3 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS DESCRIPTION Pressure controller for refrigeration systems capable to control suction (compressors) and discharge (fans) pressures. It is possible

More information

Product Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0

Product Manual. Part Number: MVP-193 Mefi-6 ECU Revision: 1.0 Product Manual Part Number: MVP-193 Mefi-6 ECU Revision: 1.0 Copyright Controls, Inc. P.O. Box 368 Sharon Center, OH 44274 Phone 330.239.4345 Fax 330.239.2845 www.controlsinc.com TABLE OF CONTENTS PRIOR

More information

GSC400 Series. Automatic Gen-Set Controller Manual. Revision 2.6

GSC400 Series. Automatic Gen-Set Controller Manual. Revision 2.6 GSC400 Series Automatic Gen-Set Controller Manual Revision 2.6 GSC400 Automatic Gen-Set Controller Installation and User Manual MAN-0076 Rev2.6, GSC400 User Manual.doc, May 2010 2 of 105 Thank You For

More information

INSTALLATION GUIDE. FCC ID NOTICE

INSTALLATION GUIDE.  FCC ID NOTICE REV.5 RS. ADVANCED REMOTE STARTER INSTALLATION GUIDE www.security.soundstream.com FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This

More information

iguard Digital Generator Set Controller Installation and Operations Manual Section 75

iguard Digital Generator Set Controller Installation and Operations Manual Section 75 iguard Digital Generator Set Controller Installation and Operations Manual 00-02-0522 09-24-12 Section 75 In order to consistently bring you the highest quality, full featured products, we reserve the

More information

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...

More information

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference

More information

4.2 Component Identification

4.2 Component Identification Digital Control Panels Deep Sea Electronics 5220 4.1 General 4.2 Component Identification 4.3 The YML5220 Controller 4.4 Description of Controls 4.5 Navigation 4.5.1 General Navigation 4.5.2 The Event

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC DEEP SEA ELECTRONICS PLC 703 AUTOMATIC START MODULE OPERATING INSTRUCTIONS Author:- John Ruddock 703 Operating Instructions Issue Beta1 25/08/2003 2:45 PM JR - 1 - >

More information

SCHNITZ MOTORSPORTS PNC-202, 2-STAGE PROGRESSIVE NITROUS CONTROLLER USER MANUAL AND INSTALLATION GUIDE NOS PULSE FREQUENCY

SCHNITZ MOTORSPORTS PNC-202, 2-STAGE PROGRESSIVE NITROUS CONTROLLER USER MANUAL AND INSTALLATION GUIDE NOS PULSE FREQUENCY SCHNITZ MOTORSPORTS PNC-202, 2-STAGE PROGRESSIVE NITROUS CONTROLLER USER MANUAL AND INSTALLATION GUIDE NOS #2, FUEL SOLENOID(GROUND) 1GA PURPLE, PAGE 14 NOS #2 NITROUS SOLENOID(GROUND) 1GA PURPLE, PAGE

More information

B-RAD Select USER MANUAL TABLE OF CONTENTS

B-RAD Select USER MANUAL TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...

More information

PowerCommand. GenSet Controls. Digital Paralleling Control

PowerCommand. GenSet Controls. Digital Paralleling Control GenSet Controls PowerCommand Digital Paralleling Control PowerCommand Operator Panel, including graphical display and analog AC metering. Description The PowerCommand Control (PCC 3200) is a microprocessor-based

More information

HSL-WI6 Ragsdale Bodymaker High Speed Logic Option User's Manual

HSL-WI6 Ragsdale Bodymaker High Speed Logic Option User's Manual HSL-WI6 Ragsdale Bodymaker High Speed Logic Option User's Manual Systems Engineering Associates, Inc. 14989 West 69th Avenue Arvada, Colorado 80007 U.S.A. Telephone: (303) 421-0484 Fax: (303) 421-8108

More information

Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical

Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical PowerView PV380-R2 Murphy Standard Configuration Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical safety

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Installation and Operating Manual. ActuCOM R8 IOM 8-18

Installation and Operating Manual. ActuCOM R8 IOM 8-18 Installation and Operating Manual Table of Contents 712 Trumbull Avenue Girard, Ohio 44420 1 General Information...4 1.1 Purpose and Scope...4 1.2 Audience...4 1.3 Intended Applications...4 1.4 Basic Control

More information

DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE

DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE STANDARD FEATURES Automatic and manual start Multi genset synchronization (up to 8 gensets) Multi genset load sharing (up to 8 gensets) Both

More information

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic CONTENT 1. SUMMARY... 4 2. PERFORMANCE AND CHARACTERISTICS... 4 3. SPECIFICATIONS... 5 4. OPERATION... 6 5. PROTECTION...

More information

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION

Installation, Operation, and Maintenance Manual CEMLINE CORPORATION $5.00 Installation, Operation, and Maintenance Manual CEMLINE CORPORATION CEM-TROL II Solid State Control Module and Electronic Control Valves P. O. Box 55, Cheswick, PA, 15024 Phone: (724) 274-5430 FAX

More information

HGM6310D/6320D AUTOMATIC GENERATOR MODULE USER MANUAL

HGM6310D/6320D AUTOMATIC GENERATOR MODULE USER MANUAL HGM6310D/6320D AUTOMATIC GENERATOR MODULE USER MANUAL SMARTGEN ELECTRONIC CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 6 4 OPERATION... 7 4.1 KEY FUNCTION... 7 4.2 AUTOMATIC

More information

EZ-TRAC Digital Tension Readout and Control

EZ-TRAC Digital Tension Readout and Control Magnetic Power Systems, Inc. 1626 Manufacturers Drive. Fenton, MO 63026 Tel: 636.343.5550 Fax: 636.326.0608 magpowr@magpowr.com INSTRUCTION MANUAL EZ-TRAC Digital Tension Readout and Control Table of Contents

More information

MaxxForce DT, 9, 10 ( )

MaxxForce DT, 9, 10 ( ) MaxxForce DT, 9, 10 (2007-2009) Overview: Idle Shutdown Timer (Non-CARB Certified Engines) NAV_IST_030711 Idle Shut Down Timer TABLE OF CONTENTS General Overview: Idle Shutdown Timer... 1 Description and

More information

NOTICE. Installation of MAM 8** can be performed only by professional technician

NOTICE. Installation of MAM 8** can be performed only by professional technician NOTICE Please read instruction manual before use Installation of MM 8** can be performed only by professional technician Installation of the MM controller needs to take into consideration heat dissipation

More information

AUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual

AUTO-EC-3-E-PLC Electric Filter Backwash Controller Operation & Maintenance Manual AUTOEC3EPLC Electric Filter Backwash Controller Operation & Maintenance Manual Contents Contents Controller Basics 3 Controller Components 4 Screen Flow Diagram Controller Functions 6 Installation 7 Warranty

More information

Operator s Series 300 Generator Paralleling System

Operator s Series 300 Generator Paralleling System Operator s Series 300 Manual Generator Paralleling System +Before reading please note the following: DANGER is used in this manual to warn of a hazardous situation which, if not avoided, will result in

More information

HGM9510 GENSET PARALLEL (WITH GENSET) UNIT USER MANUAL

HGM9510 GENSET PARALLEL (WITH GENSET) UNIT USER MANUAL HGM9510 GENSET PARALLEL (WITH GENSET) UNIT USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co., Ltd. No.

More information