WARNING. Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill. Components: AWG (0.82mm) Wire-UL Approved

Size: px
Start display at page:

Download "WARNING. Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill. Components: AWG (0.82mm) Wire-UL Approved"

Transcription

1 Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill Components: 1. 1 AWG (0.2mm) Wire-UL Approved *Under certain conditions, a heavier gauge wire may be necessary. 2. General LED PS-60W V Power Supply (Advance 60W or W) 3. AgiLight SignRayz LED Modules 4. Power-Limited Tray Cable - UL Listed 5. #6 or # (M3 or M4) screws or 1/ inch (3.2mm) rivets AWG ( mm) wire connectors or 22-1 AWG ( mm) wire nuts, IDC connectors or butt splices connectors, Cable ties-ul Approved WARNING RISK OF ELECTRICAL SHOCK Turn OFF power before before perfoming any any maintenance.

2 Module Installation 1. Remove all debris from the inside of the channel and clean inside of channel with denatured alcohol. Allow alcohol to dry before proceeding. 2. Place modules in sign according to layout. Cut product accordingly. *Product may be cut in between modules 3. To adhere the product to letter back, remove liner from tape and firmly press LED modules in place. Repeat process for the rest of layout. or 4. Screws, rivets or silicone may also be used to attach LED modules to letter back if mechanical fasteners are required or desired. *Use #6(M3) or #(M4) hexagonal or pan head metal screws or 1/ inch (3.2mm) rivets. 5. Drill an access hole near the beginning of the LED module and fit with an insulating for feeding supply wire to the product. *Access hole should be approximately ¼ inch (6.4mm) in diameter, minimum.

3 6. Remove debris from inside of channel and clean inside of channel. LED Module Wiring Instructions 1. Use an appropriate wire connectors to cover the ends of exposed wires not being used as a connection point. 2. To connect (splice) wires, use an in-line (IDC) connector or a twiston wire connector. Wires: Black (-) White/Color (+) SignRayz TM Series Input Voltage: VDC 1AWG leads Positive + (white/color) Negative - (black) General LED 60W Power Supply PS-60W V DC output: 1AWG leads Positive + (red) Negative - (black) 3. Connect the power supply to the product via the access hole in the letter back. *Use the proper gauge wire for connecting power supply to product. *Must use approved power supply: General LED PS-60W V. *All electrical connections should be made within the channel letter. *Do not overload the power supply. *The grounding and bonding of the LED Driver must be done in accordance with ordnance National Electric Code (NEC) Article 600. *Follow all National Electric Codes (NEC) and local codes.

4 Power Supply Wiring Instructions AC INPUT (3*AWG #1) DC OUTPUT (2*AWG #1) 1. AC Input wires: Black=Line, White=Neutral, Green=Ground DC Output wires: Black=Negative (-), Red=Positive (+) *Have a licensed electrician make connections to primary (AC) input. *Per NEC 200 Articles through , secondary class 2 cables do not require conduit when installing. *Seal all wall penetrations with silicone to avoid intrusion of water. Mounting Tabs Mounting Tabs 2. For mounting purposes, there are mounting tabs on either end of the power supply with several different positions to aide in ease of mounting. Power Supply Load Chart STANDARD (ft) Model W 35W 60W LS-BASE-XXX-GX LS-CORE-XXX-GX LS-APEX-XXX-GX LS-APX3-XXX-GX METRIC (m) W W W Wire Gauge Chart Wire Gauge (AWG) MAXIMUM DISTANCE* STANDARD (ft) METRIC (m) *Distance from power supply to load (at full capacity) LS-LITE-XXX-GX LS-COLOR-Reds,BL,GR-GX LS-COLOR-OR,YE-GX LS-CLR3-RR-GX LS-CLR3-YE-GX LS-MINI-XX-GX Series Parallel 40.2 LS-3MIN-XX-GX Series Parallel LS-CORE-XXX-G LS-APEX-XXX-G

5 Transformer Box Installation (for PS-60W V) 1. Determine desired location for the box. 2. Attach the box to the substrate. Screw through the middle and lower channels. (When used in a wet location, attach box to substrate using screws with rubber gasketed heads.) * The Transformer box is to be attached in all applications with the 13/16 holes always facing down. 3. Using the maximum ½ long self-tapping screw, attach the transformer* to the raised platform. * See transformer manufacturer s specification for clearances. 4. The bottom of the box has 3 standard 13/16 diameter holes and 2 pilot holes for additional 13/16 holes. 5. Use the middle back 13/16 hole. Attach your metal conduit nipple from the safety disconnect switch box. It is important that the primary (0 VAC) wires be separated from the secondary (DC) circuit wires as much as possible. Make all the 0 VAC splices in the safety disconnect box. No excess 0 VAC wiring should be in the transformer box. * Keep all secondary wiring as far away from the primary wiring as possible. ** Remember that this location is a dry/damp area. Use the appropriate conduit and strain relief products. 6. Use the included # x ½ machine screw as the grounding lug. This lug can be attached to the box either with the threads and two Green nuts facing the inside of the box or so they face outside the box. The hole in the bottom of the box between the two 13/16 holes is for the attachment of the grounding lug. Attach the grounding wires from the LED letters to the box (if grounding of the letters is required). Place the faceplate on the box, push up under the lip and secure with self-drilling screws to the box.

6 All LED modules are OFF or some of the LED modules are not illuminated No power to input of power supply Check AC input to power supply for proper connection, input voltage and/or check circuit breaker. Wrong voltage power supply Ensure proper power supply is used for input voltage at site. Bad/Loose connections Check wire connection(s) at the primary and secondary sides of the power supply for improper termination(s) or short circuits. Properly terminate or replace the wire connection(s) if needed. LED modules connected in reverse polarity Check that the white or colored wire (+) of the LED modules are connected to the positive red wire (+) of the power supply and the black wire (-) of the LED strip is connected to the negative black wire (-) of the power supply. Hot spots and/or shadows Power supply or power supplywires may be blocking light. Check that the power supply is not obscuring the modules. Adjust the wires or wire connectors to ensure they do not obscure any of the LEDs. Entire section does not light or lights intermittently Bad/Loose/Improper connections Check the wire connection on the secondary side of the power supply. A bad connection or a reversed polarity connection will cause the modules to not light. Power supplies spaced too close together Ensure proper spacing demands of General LED class 2 power supply. *Only 2 power supplies approved for installation in a standard neon transformer box. One module does not light, but all others in the sign light LED module may be defective or damaged SignRayz are wired in parallel so that if one module fails, it will not cause the entire sign or leg to fail. If one module does not light, it may be replaced by splicing in a new one.

7 LEDs flicker or appear dim Power supply may not be loaded properly with LED modules. Power supply may be damaged or defective. Power supply may be under loaded or overloaded with LED modules. Adjust loads on power supply so each load is appropriate for the power supply. Refer to the load chart for proper loading of the power supply. Possible malfunction of the power supply. May need to replace power supply, please contact an AgiLight Customer Service Representative General LED, Inc Arion Parkway, Ste 10 San Antonio, TX 7216 United States of America General LED Power Supply The maximum case temperature shall not exceed ºC when used in end product. These products are intended to be connected to a max. 20 A branch circuit. These products are intended for use in dry and damp location. The maximum leakage current measured from the metal enclosure is 0.76 ma. This needs to be considered if the end product is cord and plug connected. SignRayz TM Series SignRayz are only suitable for connection to a circuit from a class 2 power source. SignRayz have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited supplies. SignRayz are suitable for wet, damp or dry locations. SignRayz are not required to be enclosed or protected from weather. SignRayz is a volt system with a 5amp max load when connected to a UL Recognized (UYMR2) Class 2 supply.

PDX and PX Retrofit Series

PDX and PX Retrofit Series UNIQUE LIGHTING SOLUTIONS PDX and PX Retrofit Series PDX1-1-12-XX PX1-1-12-X-X-XX-65 RETROFIT INSTALLATION GUIDE PDX and PX Series Retrofit WARNING -Retrofit installation must only be performed by a licensed

More information

Installation Instructions: HYPERION R-Lite SYSTEM

Installation Instructions: HYPERION R-Lite SYSTEM Installation Instructions: HYPERION R-Lite SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read

More information

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM Installation Instructions: ACCENT HIGH OUTPUT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS

More information

SloanLED THINLED. Constant Current. Installation Guide

SloanLED THINLED. Constant Current. Installation Guide SloanLED THINLED Constant Current Installation Guide Product covered in this guide: ThinLED CC: Part Number Description 701228-18-A Amber ThinLED Constant Current 701228-18-B Blue ThinLED Constant Current

More information

Installation Instructions: ACCENT SYSTEM

Installation Instructions: ACCENT SYSTEM Installation Instructions: ACCENT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read this entire

More information

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide Installation Guide Volt Tetra minimax LED Lighting System GEMMRD-W, GEMMGL-W, GEMMBL-W BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSMENT RISK OF ELECTRIC SHOCK Turn

More information

LumaFilm Light Emitter Installation Instructions

LumaFilm Light Emitter Installation Instructions LumaFilm Light Emitter Installation Instructions (Supplement) These Instructions are intended to be used as an installation guide to be completed by, or under the direction of a qualified electricians

More information

Technical Installation Manual

Technical Installation Manual Lighting Step and Aisle Safety Lighting Technical Installation Manual 1 Contents Page 3 Tools required 4 Installation detail & planning 5 Adhesives, silicone & crimps 6 General cinema layout 7 Basic wiring

More information

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product. Tetra Contour LS LED Lighting System GEXNLBL-1, GEXNLGL-1, GEXNLRD-1, GEXNL65-1, GEXNL32-1 Installation Guide 24 Volt BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT

More information

Assembly Instructions Retrofitting

Assembly Instructions Retrofitting Assembly Instructions Retrofitting These instructions are for replacing existing lighting fixtures or systems with our new, higher efficiency TLS, drivers and controls. www.tls-lumisign.com 514-858-6556

More information

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming CONSTANT VOLTAGE POWER SUPPLIES CONSTANT VOLTAGE New dimming drivers are compatible with most wall dimmers for 10-100% light control. For non-dimming applications or for use with AL-PWM-6A, use LED-DR

More information

MASTERsine Inverter PXA Series Installation Guide

MASTERsine Inverter PXA Series Installation Guide Backup Power System Expert TM MASTERsine Inverter PXA Series Installation Guide Important Safety Instructions IMPORTANT: Read and save this Installation Guide for future reference. This chapter contains

More information

2 4 L R I G I D L E D L E D S I M U L AT E D N E O N I N S TA L L AT I O N G U I D E MANUAL FOR 48 SYSTEM ADVANCE POWER SUPPLY ONLY!

2 4 L R I G I D L E D L E D S I M U L AT E D N E O N I N S TA L L AT I O N G U I D E MANUAL FOR 48 SYSTEM ADVANCE POWER SUPPLY ONLY! R I G I D L E D L A S E R T M / L E O N L E D S I M U L AT E D N E O N T M 2 4 L I N S TA L L AT I O N G U I D E MANUAL FOR 48 SYSTEM ADVANCE POWER SUPPLY ONLY! 185-1976 Philips Advance 100W 24V LOW VOLTAGE

More information

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light installation Manual English Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified

More information

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable. 5 YEAR SYSTEM WARRANTY 5 YEAR SYSTEM WARRANTY COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL Exterior Cutout TILE Exterior TILE Jumper Cable T-Cable End Cap Cable Clamp Power Supply Control Module Waterproof

More information

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12) 0 Edge Lighting. All Rights Reserved. 78 W. Fullerton Ave Chicago, IL 606 Tel: 77-770-9 Fax: 77-9-6 www.edgelighting.com info@edgelighting.com Installation Instructions for Port Round & Square LED PORT-RD-ST-SA

More information

Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON

Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON LLI-N2.9W Prior to installation, please confirm that you have the required system components listed below. LED Neon Flow Extrusions/Lens (Optional)

More information

LED LINEAR INSTALLATION GUIDE RED 20L VER /13/

LED LINEAR INSTALLATION GUIDE RED 20L VER /13/ LED LINEAR INSTALLATION GUIDE RED 20L VER. 1.0 3/13/17 918.622.4978 www.lektroninc.com sales@lektroninc.com GETTING STARTED CONTENTS Following these few simple steps will ensure a successful installation

More information

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices. 5 YEAR WARRANTY 5 YEAR WARRANTY COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS E354088 LISTED AC E354088 58VDC E354088 E354088 5 5 YEAR WARRANTY 5 YEAR WARRANTY E354088 Caution: Observe precautions for

More information

INSTRUCTIONS. Power Panel. Installation Instructions

INSTRUCTIONS. Power Panel. Installation Instructions Overview LuXout Shade 18 Output - For use with LuXout Shades NOTICE: This power supply is built-in fan on/off control circuit. Fan automatically works according to working temperature. SHOCK HAZARD Risk

More information

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual Combiner Box Installation & Operations Manual SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual TABLE OF CONTENTS Notices and Safety Precautions Pages 1-2 Combiner

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC1-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

RibbonFlex Pro LED Accent Lighting White LED Tape Light. Welcome to RibbonFlex Pro LED Tape Lighting. Notes:

RibbonFlex Pro LED Accent Lighting White LED Tape Light. Welcome to RibbonFlex Pro LED Tape Lighting. Notes: RibbonFlex Pro LED Accent Lighting White LED Tape Light 30 White LEDs per meter (9 LEDs per foot) Model # RF3528030 rev 01.14 Welcome to RibbonFlex Pro LED Tape Lighting Ultra thin and flexible, RibbonFlex

More information

Dry Contact Closure Interface

Dry Contact Closure Interface Dry Contact Closure Interface Overview LuXout Shades Dry Contact Closure Contact closure interfaces allows integration of the Automation systems throughout the house. The contact closure interface communicates

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

STREET WRAP INSTALLATION GUIDE

STREET WRAP INSTALLATION GUIDE STREET WRAP INSTALLATION GUIDE www.p-led.com 325.227.4577 W warranty 5 P 5 L GETTING STARTED Following these few simple steps will ensure a successful installation each time. Read all instructions, before

More information

SloanLED LEDStripe Installation Guide SloanLED (888) 747-4LED

SloanLED LEDStripe Installation Guide SloanLED (888) 747-4LED SloanLED LEDStripe Installation Guide SloanLED (888) 747-4LED www.sloanled.com WI-09-237 Rev. J P/N 701202 3.15.06 SloanLED Page 1 of 22 Scope: This procedure is designed to aid in the installation of

More information

Installation and Construction Notes for EVSE4

Installation and Construction Notes for EVSE4 Installation and Construction Notes for EVSE4 You need to read and understand this if you want to build an EVSE that will be safe and need to pass a building inspectors review. Before beginning this process

More information

P-LED.com (325) INSTALLATION GUIDE

P-LED.com (325) INSTALLATION GUIDE P-LED.com (325) 227.4577 INSTALLATION GUIDE GETTING STARTED CONTENTS Page 2 Mounting Bracket Layout Page 3 Installing Street Wrap into Mounting Brackets Page 4 How to Wire RGB Page 5 Custom Cut to Fit

More information

G2.1 RETROFIT LED LIGHTING

G2.1 RETROFIT LED LIGHTING INSTALLATION INSTRUCTIONS FOR CHEVRON CANOPY: G2.1 RETROFIT LED LIGHTING Please review site plans before proceeding. Contact LSI Graphic Solutions Plus Customer Service at 1-(800) 678-2001 for installation

More information

LED LINEAR AMBER 20L INSTALLATION GUIDE /01/16 VER. 1.0 CERTIFIED SAFETY US CA

LED LINEAR AMBER 20L INSTALLATION GUIDE /01/16 VER. 1.0 CERTIFIED SAFETY US CA LED LINEAR AMBER 20L INSTALLATION GUIDE VER. 1.0 9/01/16 www.lektroninc.com 918.622.4978 CERTIFIED SAFETY US CA GETTING STARTED CONTENTS Following these few simple steps will ensure a successful installation

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST The following checklist is an outline of the general requirements found in the 1999 National Electrical Code (NEC) Article 690 for Photovoltaic (PV) Power

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

INSTALLATION MANUAL. Melink Corporation (513) Revision

INSTALLATION MANUAL. Melink Corporation (513) Revision INSTALLATION MANUAL Revision 130711 Table of Contents Step Installation Contractor Page 1 Install System Controller Electrical 4 2 Install Variable Frequency Drive Electrical 6 3 Install Touchpad Mechanical

More information

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY WARNING Risk of fire or electrical shock. LED retrofit installations require knowledge of luminaire electrical systems. If not qualified,

More information

METERING REQUIREMENTS

METERING REQUIREMENTS METERING REQUIREMENTS KUA will not accept a non-securable service trough entrance. That is, all enclosed conductors prior to the meter (line side) will be securable by and accessible to KUA personnel only.

More information

channel damage the internal components and the weight may break the internal wiring or flexible strip.

channel damage the internal components and the weight may break the internal wiring or flexible strip. YOU MAY NEED End cap Power adaptor Connector pin Splicing pin Connector Silicone glue Pliers Power converter Converter + surge protector Heat shrink Aluminium channel Heat gun NT cutter IMPORTANT NOTES

More information

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: 20180126 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency

More information

Stik Families GENERAL PURPOSE RETROFIT SIGN CONVERSION FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS

Stik Families GENERAL PURPOSE RETROFIT SIGN CONVERSION FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS Stik Families Qwik Stik, Street Stik, Slim Stik, Tap Out Stik Product Retrofit Guide WARNING Installation must only be performed by a licensed electrician. To prevent death, injury or damage to property

More information

COOLEDGE TILE EXTERIOR INSTALLATION INSTRUCTIONS FIT-2. Caution: Observe precautions for handling electrostatic sensitive devices.

COOLEDGE TILE EXTERIOR INSTALLATION INSTRUCTIONS FIT-2. Caution: Observe precautions for handling electrostatic sensitive devices. 5 YEAR SYSTEM WARRANTY 5 YEAR SYSTEM WARRANTY COOLEDGE TILE EXTERIOR INSTALLATION INSTRUCTIONS FIT-4 FIT-3 FIT-2 TILE EXTERIOR FIT-1 POWER SUPPLY AC T-CABLE END CAP CONTROL MODULE CONNECTOR CAP Caution:

More information

INSTALLATION INSTRUCTIONS DOCUMENT REVISION : /17/2014

INSTALLATION INSTRUCTIONS DOCUMENT REVISION : /17/2014 INSTALLATION INSTRUCTIONS DOCUMENT REVISION : 1.0 10/17/2014 LPF COMPONENT LIST LPF W/ WIRE & GROMMET ( 1 ) M6 X 20MM SCREW ( 2 )* LPF DRIVER BOX ( 1 ) REVERSE CIRCUIT WIRE ( 1 ).25 THICK LICENSE PLATE

More information

LIGHTNING PROTECTION UNIT (LPU)

LIGHTNING PROTECTION UNIT (LPU) LIGHTNING PROTECTION UNIT (LPU) Photovoltaic Lightning Protection Device Installation and Operation Manual SPECIALTY CONCEPTS, INC. 8954 Mason Ave. Chatsworth, CA 91311 USA MODELS COVERED: LPU-50, LPU-150,

More information

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 16 1 AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Section Contents 1. Installing a mounting bracket and light

More information

M-3025CB-AV Fuel Pump

M-3025CB-AV Fuel Pump SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...

More information

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST The following checklist is an outline of the general requirements found in the 2005 National Electrical Code (NEC) Article 690 for Photovoltaic

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC-1 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND

More information

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS 99-24283-I001 Table of Contents 1. 24V LED Approved Drivers 5 1.1. 24V LED Driver (60-19910-0002).. 5 2. Optimax Radiant 24V LED Lighting. 6 2.1. OP30 6 2.2.

More information

NUTP7-LED (Amber Finish) NUTP7-WLED (White Finish) 24V LED Tape Light Roll. Source: 24W Watts Per Foot CRI. 24V LED Tape Light Roll

NUTP7-LED (Amber Finish) NUTP7-WLED (White Finish) 24V LED Tape Light Roll. Source: 24W Watts Per Foot CRI. 24V LED Tape Light Roll ILLUMINATING THE FUTURE...SINCE 1989 NUTP7-LED (Amber Finish) NUTP7-WLED (White Finish) 24V LED Tape Light Roll PRODUCT DESCRIPTION Nora s very low profile, energy efficient LED tape is only 7/16" wide

More information

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present TOMMY GATE OWNER'S / OPERATOR'S MANUAL 650 Series 650 LB Capacity 650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present Installing the Base Plate 1. Examine the interior

More information

Sensor Activated Lavatory Faucet Installation, Operation & Service Instructions Model Numbers Tools & Materials Need Help?

Sensor Activated Lavatory Faucet Installation, Operation & Service Instructions Model Numbers Tools & Materials Need Help? Ultra-Sense Sensor Activated Lavatory Faucet S-6080-AC-12V-SSUP S-6080-ACM-12V-SSUP Installation, Operation & Service Instructions Model Numbers S-6080-AC-12V-SSUP Single supply sensor faucet and AC wall

More information

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903) ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX 75568 (903) 897-0737 fax (903) 897-0740 Pedestal Starter-Disconnect Pedestal Starter Controller Installation Instructions

More information

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions. Models beginning with MO, MK, 7B, 6S, 6F or 5B The Mini Meter Product Description Technical Specifications Installation Instructions February 28 th, 2013 1. Product Description...2 1.1 General Description...2

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND

More information

install o IIVIPORTANT - Savethese -&WARNING - -&WARNING - This appliance must -&WARNING - Before beginning the Mode_s PB970, PB975

install o IIVIPORTANT - Savethese -&WARNING - -&WARNING - This appliance must -&WARNING - Before beginning the Mode_s PB970, PB975 install m ctric Ran Mode_s PB970, PB975 I[_ Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com I BEFORE YOU BEGIN Read these instructions completely and carefully. o IIVIPORTANT

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND

More information

Hummer H up A Hummer H3T up A. 3-5 Hours INSTALLATION GUIDE INSTALLATION TIME SKILL LEVEL.

Hummer H up A Hummer H3T up A. 3-5 Hours INSTALLATION GUIDE INSTALLATION TIME SKILL LEVEL. INSTALLATION GUIDE APPLICATION MODEL YR PART # Hummer H3 2006 - up 5116-01A Hummer H3T 2009 - up 5116-01A INSTALLATION TIME 3-5 Hours Professional installation recommended SKILL LEVEL 1 2 3 = Experienced

More information

TD3 Series UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE TD3-1-UN-65 TD3-3-UN-65

TD3 Series UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE TD3-1-UN-65 TD3-3-UN-65 TD3-1-UN-65 TD3-3-UN-65 RETROFIT INSTALLATION GUIDE UNIQUE LIGHTING SOLUTIONS WARNING Retrofit instaation must ony be performed by a icensed eectrician. To prevent death, injury or damage to property this

More information

LED STRIP LIGHTING KIT EUKT04 WW30

LED STRIP LIGHTING KIT EUKT04 WW30 LED STRIP LIGHTING KIT EUKT04 WW30 This kit comes complete with everything you will need to light up your project. It includes a deluxe LED dimmer controller, a mated AC/DC power supply, 16 4 of LED strip

More information

8300 Series Installation Guidelines

8300 Series Installation Guidelines 1-800-443-4859 8300 Series Installation Guidelines WARNING: RISK OF ELECTRICAL SHOCK OR BURNS. THIS CONVERTER ASSEMBLY SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN OR CERTIFIED RV TECHNICIAN. IMPROPER

More information

INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES)

INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES) LIFT CORPORATION Sht. 1 of 22 DSG# M-16-32 Rev. - Date: 12/13/16 INSTRUCTIONS, (FORD) SUPER DUTY INSTALLATION KIT (C2 PICKUP LIFTGATES) FORD SUPER DUTY F-250, F-350 & F-450 PICKUP TRUCKS, 2017 MODEL KIT

More information

LED REVEALS - INSTALLATION INSTRUCTIONS

LED REVEALS - INSTALLATION INSTRUCTIONS SEPTEMBER 2017 PAGE 1 Fry Reglet s Reveals are designed to be installed in conventional drywall construction and will accommodate board thickness. Standard installation is quick and easy similar to the

More information

Wiring the 2016 FRC Control System

Wiring the 2016 FRC Control System Wiring the 2016 FRC Control System This document details the wiring of a basic electronics board for bench-top testing. The images shown in this section reflect the setup for a Robot Control System using

More information

INTEGRID TRACK (120V) SPECIFICATIONS

INTEGRID TRACK (120V) SPECIFICATIONS INTEGRID TRACK (120V) SPECIFICATIONS GENERAL Integrid Track shall be a combination Track and main runner for mech - anically supporting suspended ceiling systems. Integrid Track shall allow fixtures to

More information

Troubleshooting Guide: 355 Lights (12V)

Troubleshooting Guide: 355 Lights (12V) Troubleshooting Guide: 355 Lights (12V) Contents Description Refer To: Troubleshooting - Troubleshooting Chart Adjustments / Repair Procedures Bulb Replacing the Bulb Fuse(s) Replacing the Fuse (Ceiling)

More information

Installation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System

Installation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System Installation and Operation Guide Tundra HD 2500 Power Inverter for the Webasto BlueCool Truck System www.tundrainternational.com www.techwebasto.com BCTSP0063A Table of Contents 1. Introduction 4 1.1 Disclaimer.................................................................................

More information

VR44-MU-xxx-8yy-xxxxA

VR44-MU-xxx-8yy-xxxxA 44 UNIVERSAL INPUT LINEAR LED RETROFIT KITS Suitable for 2 x 4 luminaires Suitable for use in retrofit rebate programs Kitted for ease of Installation with provided harness Universal Voltage with 0-0V

More information

NEC 2011 Code Changes

NEC 2011 Code Changes NEC 2011 Code Changes Articles 280.21-300.50 CHANGES FROM 2008 TO 2011 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1kV III. Connecting Surge Arresters 280.21 Connection

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit Instruction Sheet 10-2004 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch.

More information

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series) LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series) PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION SAFETY

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL Photovoltaic (PV) Residential Page 1 of 10 Revision Date: 07/18/2018 INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL INSPECTION CODE: 703 SCOPE: RESIDENTIAL APPLICABLE CODES: 2016 CBC, CRC, CPC,

More information

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS Ultra Performance LED Tube Installation Instructions Page 1 of 7 ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS These instructions do not purport to cover all details or variations in components

More information

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual Touch-Plate Lighting Controls ACES 3 & 6 Module System Manual A.C.E.S. Series ACES 3 & 6 MODULE PANELS System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323

More information

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present TOMMY GATE OWNER'S / OPERATOR'S MANUAL 650 Series 650 LB Capacity 650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present Installing the Base Plate 1. Examine the interior and exterior

More information

MODEL ELC-12/60-D BATTERY CHARGER

MODEL ELC-12/60-D BATTERY CHARGER *32198* NATIONAL RAILWAY SUPPLY Installing, Operating and Service Instructions for the 12/60 Solid State Charger MODEL ELC-12/60-D BATTERY CHARGER PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS

More information

Wiring the 2015 FRC Control System

Wiring the 2015 FRC Control System Wiring the 2015 FRC Control System This document details the wiring of a basic electronics board for bench-top testing. The images shown in this section reflect the setup for a Robot Control System using

More information

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of

More information

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by

More information

High Frequency SineWave Guardian TM

High Frequency SineWave Guardian TM High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation

More information

McDonalds Installation Guide

McDonalds Installation Guide McDonalds Installation Guide Canopy COD Installation CCOD ------------------------------------------------------------------------------------------------------ Metal Pedestal COD Installation MCOD Everbrite

More information

AccuPower AQU126B Installation Instructions

AccuPower AQU126B Installation Instructions Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU126B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC2-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS The original TOMMY GATE hydraulic lift Assembling the Auxiliary Battery Box 1. Remove the cover from the auxiliary battery box by removing the two nuts and

More information

Electric Range installation manual

Electric Range installation manual Electric Range installation manual This manual is made with 100% recycled paper. imagine the possibilities ENGLISH Thank you for purchasing this Samsung product. To receive more complete service, please

More information

VMU048012LP8xxA 5.5 LP-LINEARHO DC MODULE, 480mA MAX CURRENT

VMU048012LP8xxA 5.5 LP-LINEARHO DC MODULE, 480mA MAX CURRENT 5.5 LP-LINEARHO DC MODULE, 480mA MAX CURRENT Low Profile design, no magnets Direct mount to luminaire housing Superior thermal performance than standard LinearHO Higher aluminum material density Extruded

More information

Terminator. DP Power Connection Kit INSTALLATION PROCEDURES

Terminator. DP Power Connection Kit INSTALLATION PROCEDURES Terminator TM DP Power Connection Kit For Power Connection, In-Line Splice Connection, T-Splice Connection, or End Termination Applications Receiving, Storing and Handling... 1. Inspect materials for damage

More information

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE Please read these instructions thoroughly before installing and operating the range. LDE3019ST LDE3017ST LDE3017SB LDE3017SW LDE3015ST LDE3015SB

More information

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires.

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires. MAGNETIC SUPPLY INSTALLATION SAFETY GUIDE Please read before installing. GENERAL This power supply is to be installed in accordance with Article 450 of the National Electric Code. The power supply must

More information

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge 200 Shadylane Drive Philipsburg, PA 16866 Phone: (814) 342-6205 Fax: (814) 342-4510 www.druckerdiagnostics.com Service Manual Model 642E Centrifuge MODEL 642E SERVICE MANUAL REV: Original Issue 1 CONTENTS

More information

HPNLS-HO. Installation Manual

HPNLS-HO. Installation Manual Installation Manual WARNING: Do not lift fixture by cables. This could result in permanent damage to both the fixture and the cables. Damage resulting from grasping cables and/or putting undue pressure

More information

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly. SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS (ELEC) This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1 Webinar 1 Electrical 2 1 Webinar Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock)

More information

INSTALLATION MANUAL. Thunderstone Manufacturing LLC 3400 West O Street Lincoln, NE (Fax)

INSTALLATION MANUAL. Thunderstone Manufacturing LLC 3400 West O Street Lincoln, NE (Fax) INSTALLATION MANUAL August 7 th 2018 43 /48 /50 2011 and Older Timpte STD/Split 36 Style Hopper Trailers with Roller Bearing Doors Kit #101533 for 96w & Kit #101534 for 102w Thunderstone Manufacturing

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I am inspecting a building addition. They have a 480V to

More information

VMU080030LP8xxA 22 LP-LINEARHO DC MODULE, 800mA MAX CURRENT

VMU080030LP8xxA 22 LP-LINEARHO DC MODULE, 800mA MAX CURRENT 22 LP-LINEARHO DC MODULE, 800mA MAX CURRENT Low Profile design, no magnets Direct mount to luminaire housing Superior thermal performance than standard LinearHO Higher aluminum material density Extruded

More information

JAZZ J400C (COLOR), J400AS (AUTO SYNC)

JAZZ J400C (COLOR), J400AS (AUTO SYNC) Fiberstars JAZZ J400C (COLOR), J400AS (AUTO SYNC) Owners Manual Fiberstars 44259 Nobel Drive Fremont, CA 94538 www.fiberstars.com Rev.E 08/04/04-1 - P/N 75-15046-PM CAREFULLY READ AND FOLLOW ALL SAFETY

More information

KI (14V) & KI (28V) R44

KI (14V) & KI (28V) R44 KI-228-1 (14V) & KI-228-2 (28V) R44 Radar Altimeter Installation Kit Instructions For B050 upper console only; includes parts for In-Console and Above-Console installations. NOTE Visit www.robinsonheli.com

More information

VMU140055LP8xxC 46 LP-LINEARHO DC MODULE, 1400mA MAX CURRENT

VMU140055LP8xxC 46 LP-LINEARHO DC MODULE, 1400mA MAX CURRENT 46 LP-LINEARHO DC MODULE, 1400mA MAX CURRENT Low Profile design, no magnets Direct mount to luminaire housing Superior thermal performance than standard LinearHO Higher aluminum material density Extruded

More information

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return

More information