1 AHEAD OF THE FLOW NIBCO Press System Bronze Ball Valves Two-Piece Body Full Port Bronze Trim Blowout-Proof Stem Dezincification Resistant Revised 1/6/ PSI/17.2 Bar Non-Shock Cold Working Pressure 250 F Maximum Operating Temperature CONFORMS TO MSS SP-110 MATERIAL LIST Specification Part 1. Body Bronze ASTM B584 Alloy C Body End Bronze ASTM B584 Alloy C Press End Adapter (2) Wrot Copper ASTM B75 Alloy C Ball Brass ASTM B16 Alloy C36000 or ASTM B283 Alloy C37700 (Chrome/Nickel Plated) 5. Seat Ring (2) Reinforced PTFE 6. Boss seal o-ring (2) EPDM 7. O-Ring (2) EPDM 8. Packing PTFE 9. Pack Gland Brass ASTM B16 Alloy C Stem Silicon Bronze ASTM B371 Alloy C69430 or ASTM B371 Alloy C Handle Nut Zinc Plated Steel 12. Thrust Washer Reinforced PTFE 13. Handle Assembly Zinc Plated Steel with Plastisol Coating PC Press x Press Female End DIMENSIONS WEIGHTS Dimensions SIZE A B C D E Weight In. mm. In. mm. In. mm. In. mm. In. mm. In. mm. Lbs. Kg. 1/ / / / NIBCO Press System ball valves are designed to meet MSS SP-110 with the exception of the end connection. Ball valves are down-rated from 600 PSI CWP to 250 PSI CWP to match the Press System. Male and female press-to-connect ends are new technology not yet covered in the current edition of this specification. PC P x P Handle Options: Stainless Steel Lever NIB-Seal Locking lever Stainless Steel Locking Lever Memory stop Extended lever w/ memory stop Round Wing Horizontal and vertical chain NIBCO INC. WORLD HEADQUARTERS 1516 MIDDLEBURY ST. ELKHART, IN USA PH: TECH SERVICES PH: FAX: INTERNATIONAL OFFICE PH: FAX:

2 AHEAD OF THE FLOW Class 125 Bronze Ring Check Valves Inline Lift Type Resilient Discs Spring Actuated Revised 7/3/2012 Dezincification Resistant 125 PSI/8.6 Bar Saturated Steam to 353 F/178 C (PTFE Disc) 250 PSI/17.2 Bar Non-Shock Cold Working Pressure MATERIAL LIST Specification Part 1. Body Bronze ASTM B 584 Alloy C Stem Stainless Steel ASTM A 582 Alloy C Spring 316 Stainless Steel 4. Disc Holder Stainless Steel Type Disc Water, Oil or Gas (Buna-N) Steam (PTFE) (Y) 6. Seat Screw Stainless Steel ASTM A 276 Alloy S Body End Bronze ASTM B 584 Alloy C84400 T-480 Threaded S-480 Solder DIMENSIONS WEIGHTS QUANTITIES Dimensions Size A B C T-480 S-480 Master In. mm. In. mm. In. mm. In. mm. Lbs. mm. Lbs. Kg. Ctn. Qty. ³ ₈ ¹ ₂ ³ ₄ ¹ ₄ ¹ ₂ Ordering: The T-480 and S-480 both have standard Buna-N Discs. Also available with PTFE (Y) Discs; specify T-480-Y or S-480-Y. ³ ₈" thru 2" require ¹ ₂ pound pressure to open. T-480-Y (PTFE Disc) NPT x NPT S-480-Y (PTFE Disc) C x C NIBCO Check Valves may be installed in both horizontal and vertical lines with upward flow or in any intermediate position. u For detailed Operating Pressure, refer to Pressure Temperature Chart on page 113. Warning Do Not Use For Reciprocating Air Compressor Service. 36 NIBCO INC. WORLD HEADQUARTERS 1516 MIDDLEBURY ST. ELKHART, IN USA PH: TECH SERVICES PH: FAX: INTERNATIONAL OFFICE PH: FAX:

3 LMR PLUS Electric Fire Pump Controllers Electrical Wiring Schematic FD30 Across-the-Line May 2011 Electrical Wiring Schematic LMR PLUS REMOTE START DELUGE VALVE (REMOVE JUMPER IF USED) PUMP START LOW SUCTION LOW ROOM TEMPERATURE INTERLOCK ON INPUT #1 INPUT #2 INPUT #3 INPUT #4 INPUT #5 INPUT #6 INPUT #7 INPUT #8 INPUT #9 CUSTOMER INPUTS OPTION RELAY #1 (2 SETS FORM-C) OPTION RELAY #5 (2 SETS FORM-C) OPTION RELAY #2 (2 SETS FORM-C) OPTION RELAY #6 (2 SETS FORM-C) OPTION RELAY #3 (2 SETS FORM-C) OPTION RELAY #7 (2 SETS FORM-C) OPTION RELAY #4 (2 SETS FORM-C) OPTION RELAY #8 (2 SETS FORM-C) COMMON ALARM (NORMALLY ENERGIZED) COMMON ALARM (NORMALLY ENERGIZED) PHASE FAILURE (NORMALLY ENERGIZED) PHASE FAILURE (NORMALLY ENERGIZED) PHASE REVERSAL PHASE REVERSAL ALARM CONTACTS INTERNAL CONNECTIONS FUTURE #1 FUTURE #1 PUMP RUN PUMP RUN N. Y. C. APPROVED ES K/D For more information visit:

4

5 LMR PLUS Electric Fire Pump Controllers Field Connections FD30 Across-the-Line September 2013 Field Connections Line Terminals (Incoming Cables) Load Terminals (To Motor) External Inputs * Qty. & Cable Sizes Max HP (1)#14-1/0 PER Ø (CU/AL) (1)#14-2/0 (CU/AL) (1)#4-4/0 PER Ø (CU) (1)#4-350MCM (CU/AL) (1)#3-350MCM PER Ø (CU/AL) (1)#4-350MCM (CU/AL) (2)3/0-250MCM PER Ø (CU/AL) (2)1/0-750MCM (CU/AL) (2) MCM PER Ø (CU/AL) (2)1/0-750MCM (CU/AL) * Coils available: 380V-50Hz, 380V-60Hz, 415V-50Hz, 415V-60Hz. Max HP Line Terminals on Main Isolation Switch (Incoming Cables) LINE VOLTAGE Load Terminals (To Motor) Line Voltage Qty and Cable Sizes Single Run Double Run Alarm / Relay Outputs LMR Service Entrance GND. LUG Qty. & Cable Sizes (1) #14 - #8 PER (CU/AL) (2) #14 - #8 PER (CU/AL) (1) #14 - #1 PER (CU/AL) (2) #14 - #2 PER (CU/AL) (1) #8-3/0 PER (CU/AL) (2) #8-2/0 PER (CU/AL) (1) #2-750MCM PER (CU/AL) (2) 1/0-250MCM PER (CU/AL) (1) 1/0-500MCM PER (CU/AL) (2) 1/0-500MCM PER (CU/AL) For ambient temperatures above 30C (86F), the temperature rating of motor conductors is recommended to be a minimum of 90C (194F) For Proper Cable Size Refer to National Electrical Code NFPA-70 PLUS COMMON ALARM (NORMALLY ENERGIZED) COMMON ALARM (NORMALLY ENERGIZED) PHASE FAILURE (NORMALLY ENERGIZED) PHASE FAILURE (NORMALLY ENERGIZED) PHASE REVERSAL PHASE REVERSAL ALARM CONTACTS FUTURE #1 FUTURE #1 PUMP RUN PUMP RUN NOTE: 1. MOTOR CONNECTIONS VARY, PLEASE REFER TO SPECIFIC MOTOR CONNECTION DIAGRAM. 2. PLEASE OBSERVE PROPER PHASE ROTATION, A,B,C-L1,L2,L3 AS CONTROLLER IS PHASE SENSITIVE. 3. CABLE SIZE TO BE 125% OF FULL LOAD CURRENT. REFER TO WIRE SIZE TABLE IN NFPA 70. N. Y. C. APPROVED ES K/E For more information visit:

6 Must Be Installed Per Applicable Code and Manufacturers Recommendations 3A13357H01 3A13357H01 START STOP LMR PLUS Electric Fire Pump Controllers Dimensions FD30 Across-the-Line July 2011 Dimensions Standard Enclosure - Type NEMA 2, 3R, 4, 4X, 12 LMR PLUS [317] [721] [564] [254] [1270] [1219] [1524] 5.25 [133] 2.63 [67] Ø1.75 [Ø44] [305] 6.00 [152] [267] PIPING ENTRANCE 1/4" NPT - FEMALE 5.00 [127] PIPING ENTRANCE 1/2" NPT - FEMALE 6 Dimensions in inches and [millimeters]. 1 - START PUSHBUTTON 2 - STOP PUSHBUTTON 3 - MAIN POWER SWITCH 4 - MSH (EMERGENCY START HANDLE) 1.12 [28] 5 - MAIN LMR PLUS DISPLAY 6 - RECOMMENDED CABLE ACCESS (BOTTOM ONLY) [337] 4.24 [108] 1.14 [29] 3.32 [84] 2.09 [53] 8.42 [214] Motor Hp Line Voltage V V * V V * Coils Available: 380V-50Hz, 380V-60Hz, 415V-50Hz, 415V-60Hz Withstand Rating Standard Intermediate High 100, , , (81) V 25, ,000 Approx. Weight Lbs. (Kg) N. Y. C. APPROVED SEISMIC QUALIFIED U.B.C and C.B.C NOTES: 1. All enclosures finished in FirePump red. 2. Cable Entrance bottom only. 3. Standard Enclosure type NEMA 2. MD K/C For more information visit:

7 Must Be Installed Per Applicable Code and Manufacturers Recommendations LMR PLUS Electric Fire Pump Controllers Main Display Main Display - LMR Plus Fire Pump Controllers June 2011 Main Display LMR PLUS SILENCE ALARM MOTOR TEST POWER ON PUMP RUNNING LOCAL START REMOTE START DELUGE VALVE EMERGENCY START INTERLOCK ON LOW PRESSURE AUTO SHUTDOWN ENABLED PHASE REVERSAL PHASE FAILURE FAIL TO START UNDERVOLTAGE OVERVOLTAGE LOW ROOM TEMPERATURE LOCKED ROTOR TRIP LOW SUCTION PRESSURE SOURCE 2 DISCONNECTED LMRPLUS DATA PRINT LAMP TEST MENU RESET SAVE/EXIT ACK NOTES: 1. Refer to the LMR Plus technical manual for detail and setup information, as well as programming and custom labelling for Programmable LED # 1 and Programmable LED # 2. N. Y. C. APPROVED SEISMIC QUALIFIED U.B.C and C.B.C NOTE: As of January 1, All Limited Service Controllers will not carry FM Approval. MD K/D For more information visit:

8 DIFFERENTIAL PRESSURE Multi-Sense Model 231 Wet-to-Wet, Differential, Multi-Configurable Pressure Transducer NOTE: Setra quality standards are based on AN- SI-Z The calibration of this product is NIST traceable. U.S. Patent nos ; DESCRIPTION Setra s Model 231 Multi-Sense Wet-to-Wet differential pressure transducer all-inclusive design provides users with field accessible ranging, choice of output and field zeroing. Choose from three configurable pressure transducers: 5 up to 50 psid, 10 up to 100 psid, or 25 up to 250 psid. Each Model 231 has 4 unidirectional and 4 bidirectional switch selectable pressure ranges and can be reconfigured in the field for 0-5 VDC, 1-5 VDC, VDC, or 4 to 20 ma output. The Model 231 jumper selectable port swap feature eliminates costly replumbing if the pressure transducer is improperly installed or replaced. An optional LCD display is available for on-site indication of line and differential pressure. SPECIFICATIONS FEATURES Field Selectable Output - True 4 to 20 ma, 0 to 5, 1 to 5, and 0 to 10 VDC Field Selectable Pressure Ranges Field Accessible Push-Button Zero and Remote Zero Dual Sensors Optional 3- or 5-Valve Manifold Hinged Cover Field Selectable Port Swap Optional LCD Display All Cast Aluminum, NEMA4 Rated Housing CE and RoHS Compliant APPLICATIONS Energy Management Systems Process Control Systems Flow Measurement of Various Gases or Liquids Liquid Level Measurement of Pressurized Vessels Pressure Drop Across Filters Electrical Data (Voltage) Performance Data Environmental Data Circuit 3-Wire Accuracy RSS 1 (at constant temp.) Operating 3 Temperature F ( C) -4 to +185 (-20 to -85) Excitation 15 to 30 VDC/18 to 30 VAC (Reverse Excitation Protected) Pressure Ranges A, B, C ±1.0% FS Storage Temperature F ( C) -4 to +185 (-20 to +85) Output 4 0 to 5 VDC, 0 to 10 VDC, 1 to 5 VDC Pressure Ranges D ±2.0% FS Vibration 10g from 50Hz to 2000 Hz Output Impedance 30 Ohms Pressure Ranges Shock 200g Circuit Consumption 8 ma (typ.) at 5 VDC, 8 ma (typ) at 10 VDC40 ma (typ.) at VAC A B C D Max. Line Pressure Physical Description MS Case Die Cast Aluminum, Powder Coated Electrical Data (Current) MS Pressure Fittings 1/8-18 NPT Internal Curcuit 2-wire (Reverse Excitation Protected) MS Electrical Connection 1/2 in. Conduit Output 5 4 to 20 ma Pressure Media Size 4.0 x 6 x 2 in. (102 x 152 x 51 mm) External Load Min. Supply Voltage (VDC) 0 to 250 Ohms x (Resistance of reciever plus line). Liquids or Gases Compatible with 17-4 PH Stainless Steel Note: Hydrogen not recommended for use with 17-4 PH stainless steel 1 RSS of Non-Linearity, Hysteresis, and Non-Repeatability. 2 Units calibrated at nominal 70 F. Maximum thermal error computed from this datum. 3 Operating temperature limits of the electronics only. Pressure media temperatures may be considerably higher or lower. 4 Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater. 5 Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load. Specifications subject to change without notice. Weight Sensor Vacity Volume Max. Supply Voltage (VDC) (Resistance of reciever plus line). Thermal Effects lb 0.2 cc Compensated Range F ( C) +32 to +130 (0 to +54) Zero/Span Shift %FS/100 F (50 C) 2.0 (1.8) Warm-up Shift Response Time Proof Pressure <0.12% FS 1 to 5 sec. (selectable) Burst Pressure 15 x Full Scale (50 psi), 10 x Full Scale (75 x 150 psi), 8 x Full Scale (250 psi) 1 Phone: Fax: setra.com 2013 Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc. 2 x Full Scale

9 DIMENSIONS R Multi-Sense Model 231 Wet-to-Wet, Differential, Multi-Configurable Pressure Transducer WIRING DIFFERENTIAL PRESSURE DC/AC Power Supply Controller Voltage Relay /8 NPTF High Low Wire - Voltage Output 0 to 5 VDC 0 to 10 VDC 1 to 5 VDC Remote Zero 1/2 Conduit Opening DC Power Supply + Controller Current (4-20 ma) Relay Wire - Current Output 4 to 20 ma Remote Zero IN MM 2013 Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc. Phone: Fax: setra.com 2

10 DIFFERENTIAL PRESSURE Multi-Sense Model 231 Wet-to-Wet, Differential, Multi-Configurable Pressure Transducer DIMENSIONS (3-Valve Manifold Assembly) 3-Valve Manifold Assembly Description (Order as Pressure Code Fitting "3V".) Manifold Block Valves (3) Valve type Brass V1 for connection to +port V2 for connection to -port V3 for equalizing pressure 90 Degree On/Off Process Connections 1/4-18 NPT Internal Thread MODEL 230 DIFFERENTIAL PRESSURE TRANSDUCER V3 SHUNT VALVES V1 V1 V2 V2 SHUT OFF VALVES HIGH PROCESS CONNECTION 1/4'' NPT LOW PROCESS CONNEC- TION 1/4'' NPT For differential pressure measurements at high line pressure (250 psig max), it is recommended that the pressure sensor be installed with a valve in each line, plus a shunt valve across the high and low (reference) pressure ports as shown DIMENSIONS (5-Valve Manifold Assembly) 5-Valve Manifold Assembly Description (Order as Pressure Code Fitting 5V.) Manifold Block Valves (5) Valve Type Process Connection Brass V1 for connection to ±port V2 for connection to -port V3 for equalizing pressure V4 for connection to external gauge or alternate plumbing configuration V5 for connection to external gauge or alternate plumbing configuration 90 Degree On/Off 1/4-18 NPT Internal Thread V6 V7 Model 230 Differential Pressure Transducer SHUNT VALVE V4 V1 High Process Connection 1/4 NPT V3 V2 V5 Low Process Connection 1/4 NPT SHUT OFF VALVES Low Process/Commission 1/4 NPT Connection Phone: Fax: setra.com 2013 Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc.

11 INSTALLATION Valve A 1 High Multi-Sense Model 231 Wet-to-Wet, Differential, Multi-Configurable Pressure Transducer High Pressure Remote Sensor Pipe Model 231 Valve A = High Side Valve Valve B = Low Side Valve 1. Valves not included. Low Pressure Remote Sensor Pipe Valve B 1 Low DIFFERENTIAL PRESSURE PRESSURE RANGE CODE SELECTOR (IMPORTANT: READ BEFORE ORDERING) Examine the pressure application and determine what is the Highest System Line Pressure. Determine what is the Differential Pressure being measured. Find the MAX. Line Pressure in the table on the right that is > to your Highest System Line Pressure. Verify that your DP falls within the selectable ranges in that row. Follow that row to the left and select that range code. Example: Highest System Line Pressure: Differential Pressure Measured: Max Line Pressure to System Line Pressure: Select Range Code: Range Code 125 psig 50 psid 250 psid (50 psid DP falls within ranges in this row) MS3 A B C D Max. Line Pressure MS MS MS ORDERING INFORMATION G Model Range Code Pressure Connection Display 231G = 231G See Table 1 Below Std. 2F 1/8-18 NPT female (Standard) Sensor (Conduit Version) Table 1. Range Specification* RANGE CODE UNIDIRECTIONAL PRESSURE RANGES BIDIRECTIONAL PRESSURE RANGES MS1 5, 10, 25, 50 psid ±5, ±10, ±25, ±50 psid MS2 10, 20, 50, 100 psid ±10, ±20, ±50, ±100 psid MS3 25, 50, 125, 250 psid ±25, ±50, ±125, ±250 psid *Note: Maximum line pressure is maximum range of pressure ordered. Std. N No Display Opt. 3V 3-V Manifold assembled w/ Model 231 Opt. D LCD Display Opt. 5V 5-V Manifold assembled w/ Model 231 Ordering Example: 231GMS12FD = Model 231, 5 PSID up to 50 PSID, 1/8 NPT Female Fitting, and LCD Display 31GMS13VN= Model 231, 0 to 5 psid up to 50 PSI, 3-Valve Manifold, and No LCD Display SSP231 Rev.D 05/21/ Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc. Phone: Fax: setra.com 4

12

13

14

15 Type 1005P, XUL Fire Protection Sprinkler Service Gauge Triple Scale Dials NOW Available FEATURES Underwriters Laboratory listed and Factory Mutual approved Corrosion-resistant ABS case Heat-resistant polycarbonate push-in window Patented PowerFlex movement with polyester segment True Zero indication, a unique safety feature Ashcroft fire protection sprinkler gauges are Underwriters Laboratory listed and Factory Mutual approved for fire protection sprinkler service. The case material on Type 1005P, XUL gauges is ABS. The psi pressure range is used on wet systems where water is available to the sprinkler heads. The 0-80 retard to 250 psi pressure range is used on dry systems where the lines are filled with air pressure until system activation. The psi gauge is available for systems requiring higher pressures. Due to global demands for fire protection sprinkler gauges, Ashcroft offers UL listed, triple scale (bar, kpa, psi) dial gauges. The patented PowerFlex movement with polyester segment is designed to provide unequalled shock and vibration resistance resulting in superior performance and extended gauge life. True Zero indication, a standard feature on these gauges, reduces the potential risk of installing a damaged gauge on your equipment. PRODUCT SPECIFICATIONS Ashcroft Model No.: 1005P, XUL Accuracy: ASME B Grade B (±3-2-3% of span) Size: 3 1 /2 Case: ABS (Polycarbonate blend) Ring: None Window: Polycarbonate, push-in Dial: Black figures on white background Pointer: Black, aluminum Bourdon tube: C shaped bronze Movement: Patented PowerFlex with polyester segment Socket: Brass Restrictor: None Connection: 1 4 NPT lower Ranges: Single, dual or triple scale psi (water) 0-80 retard to 250 psi (air) psi Operating temperature: 40 F to 150 F; 40 C to 65 C UL 393 Listed, UL of Canada Listed and FM approved. Equivalent (single or dual scale) metric scales are available OPTIONAL FEATURES Customized dials Other UL listed ranges on application Black Rubber Gauge Boot Shown with Optional Rubber Boot HOW TO ORDER (Typical example) 35 W 1005 P H 02L XUL 300# Dial Size: 3 1 /2 Movement: Patented PowerFlex Case Type Number: 1005P Case Material: ABS Socket Material: Brass Connection Size/Location: 1 /4 NPT Lower Listing: UL listed, FM approved Range: 0/300 psi BULLETIN CSG-3 All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft Inc /14 Ashcroft Inc., 250 East Main Street, Stratford, CT USA Tel: Fax: info@ashcroft.com

16 Type 1005P, XUL Fire Protection Sprinkler Service Gauge DIMENSIONS A B D C G 1/4 NPT E SIZE/TYPE A B C D E G Weight oz 1005P, XUL (94) (29) (69) (92) (11.9) (14.2) kg BULLETIN CSG-3 All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft Inc /14 Ashcroft Inc., 250 East Main Street, Stratford, CT USA Tel: Fax: info@ashcroft.com

17 Fire Pump Controllers 1-1 Features LMR Plus Electric Fire Pump Controllers Typical Specifications 1. Approvals A. The Fire Pump Controller shall meet the requirements of the latest edition of NFPA 20 and shall be listed by [Underwriters Laboratories (UL)]and approved by [Factory Mutual Research (FM)] [Canadian Standards Association (CSA)] [New York Department of Buildings (NYSB)] and carry the CE marking for fire pump service. 2. Starting Type A. The controller shall be of the combined manual and automatic type designed for [Full Voltage Starting] [Part Winding Starting] [Primary Resistor Starting] [Autotransformer Starting] [Wye-Delta (Star-Delta) Open Transition Starting] [Wye-Delta (Star-Delta) Closed Transition Starting] [Solid State Soft Start Starting] 3. Ratings A. The Controller shall have a withstand rating of 100,000 RMS symmetrical [208V] [240V] [380V] [400V] [415V] [480V] 600VAC]. 4. Construction A. The controller shall include a motor rated combination isolating switch and circuit breaker, mechanically interlocked and operated with a single externally mounted handle. B. The isolating switch shall be rated to disconnect the motor load. C. The isolating switch/circuit breaker combination shall be mechanically interlocked such that the enclosure door cannot be opened when the handle is in the on position except by a tool operated defeater mechanism. D. The controller manufacturer shall manufacture the contactor, isolating switch, circuit breaker, pushbuttons, and enclosures. Brand-labeled components will not be accepted. 5. Enclosure A. The controller shall be housed in a NEMA Type 2 (IEC IP11) drip-proof, powder baked finish, freestanding enclosure. B. Optional Enclosures: 1. NEMA 3R (IEC IP14) rain-tight enclosure. 2. NEMA 4 (IEC IP66) watertight enclosure. 3. NEMA 4X (IEC IP66) watertight 304 stainless steel enclosure. 4. NEMA 4X (IEC IP66) watertight 316 stainless steel enclosure. 5. NEMA 4X (IEC IP66) watertight corrosion resistant enclosure. 6. NEMA 12 (IEC IP52) dust-tight enclosure. 6. Microprocessor Control A. The controller shall come complete with a 4 line by 40 character LCD display mounted on a panel opening in the front door. The LCD display shall indicate the following: 1. Main screen displaying system pressure, threephase voltage and amperage readings, system frequency, date, and time. 2. Set point review screen displaying the programmed pressure start and stop points, and weekly test time. 3. Controller statistics screen, including: a. Powered Time b. Motor Run Time c. Number of Calls to Start d. Number of Starts e. Last Motor Start Time f. Last Motor Run Time g. Last Low Pressure Start h. Minimum System Voltage i. Maximum System Voltage j. Minimum System Frequency k. Maximum System Frequency l. Minimum System Pressure m. Maximum System Pressure n. Last System Startup o. Last Phase Failure p. Last Phase Reversal q. Last Locked Rotor Trip r. Maximum Run Current s. Last Locked Rotor Current 4. Controller diagnostics screen, including: a. Date & Time b. Firmware Version c. Shop Order Number d. Customer Order Number e. Transformer Output Voltage f. Current Transformer Outputs g. Pressure Transducer Calibrated Settings h. Input Status i. Output Status 5. Display last messages screen that will display up to 10,000 alarms/messages stored in the controllers' memory. 6. Display up to ten (10) custom messages of up to 100 characters each, which will continually scroll across the fourth line of the display. 7. Remaining time left on active timers. B. The controller shall be supplied with ten (10) green status LED s for the following: 1. Power On 2. Pump Running 3. Local Start 4. Remote Start 5. Deluge Valve 6. Emergency Start July 2011 For more information visit: PS K/E

18 Fire Pump Controllers 1-2 Features LMR Plus Electric Fire Pump Controllers 7. Interlock On 8. Low Pressure 9. Auto Shutdown Enabled 10. Programmable LED #1 C. The controller shall be supplied with ten (10) red alarm LED s to indicate the following: 1. Phase Reversal 2. Phase Failure 3. Fail to Start 4. Undervoltage 5. Overvoltage 6. Low Room Temperature 7. Locked Rotor Trip 8. Low Suction Pressure 9. Source 2 Disconnected 10. Programmable LED #2 D. The microprocessor logic board shall be available with: 1. A USB port for transference of message history, controller status, diagnostics, and statistics and the ability to update firmware. 2. An optional Ethernet port for direct connection to a computer for data transfer. 3. An optional RS485 Serial port for communication to various external software programs. E. The controller shall be available with an embedded web page to allow viewing of the controllers' current status, data values, programmed set points, and history. F. A Fail-to-Start alarm shall occur if the motor controller sees less than 20% of the motor full load amps after an adjustable time delay of 1-90 seconds. G. Locked rotor protection shall be provided. After a trip condition and restoration of power, the LCD display shall indicate LOCKED ROTOR TRIP. H. A sequential start timer and weekly test timer shall be provided as standard. I. A restart time delay of two (2) seconds shall be provided to allow the residual voltage of the motor to decay prior to re-starting the motor. In the event that the pump motor continues to run after a request to stop, then the controller must display a fail to stop message to indicate this condition. J. Overvoltage (5-20%) and undervoltage (5-30%) sensing and alarming shall be provided as standard. K. The controller shall be supplied with interlock and shutdown circuits as standard. A flashing green LED shall indicate an interlock on condition. L. Where shutdown of the pump(s) due to low suction pressure is required, it shall be accomplished without the addition of a separate panel or enclosure. The LCD display shall indicate low suction shutdown. Resetting of the condition shall be automatic or manual as selected by the user. M. Means shall be provided to test the operation of all LED s to ensure their functionality. 7. Programming Menu A. The programming menu shall have the ability to enable an entry password. B. The programming menu shall be limited to two (2) levels of password protection. C. The controller shall have three (3) languages as a standard, English, French, and Spanish, with the ability to add a fourth language. D. The programming menu shall be grouped into 6 main menu headings as follows: 1. Regional Settings 2. Pressure Settings 3. Timer Values 4. Alarm Set points 5. Input/Output Menu 6. System Configuration (password protected) 8. Pressure Sensor A. A solid-state 4-20mA pressure sensor shall be provided. The pressure Start and Stop points shall be adjustable in increments of one (1) PSI. A low pressure pre-alarm, indicated with a flashing green LED, shall denote a potential pump starting condition and will remain lit once the pump has started to indicate the starting cause. 9. Custom Inputs/Outputs A. The controller shall come standard with nine (9) future inputs, two (2) future LED indicators, and one (1) future output, with the ability to add up to another 8 outputs via optional relay boards. B. The user shall be able to program the future inputs/outputs through the main programming menu. C. The inputs shall be selectable based on the following criteria: 1. User selected message or thirteen (13) predetermined messages. 2. Energize the common alarm relay when the input is received. 3. Link to a future relay and/or LED indicator. 4. Alarm latched until reset. 5. Normally open or closed input. 6. On-delay timer. D. The LED indicators shall be selectable based on the following criteria: 1. Indication based on a minimum of twelve (12) predetermined alarms or a custom input. E. The future relays shall be selectable based on the following criteria: 1. Output based on a minimum of twenty-seven (27) predetermined alarms, controller status or a custom input. 2. Latched until reset. 3. Energized under normal conditions. 4. On or off delay timer on the output. July 2011 For more information visit: PS K/E

19 Fire Pump Controllers 1-3 Features LMR Plus Electric Fire Pump Controllers 10. Alarm Relays A. All relays shall be of the plug-in type. An LED on the relay panel shall indicate the energized state of the relay. All relay contacts shall be 8A, 277VAC/30VDC. Two (2) sets of Form-C contacts shall be provided for each of the following: 1. Phase Reversal 2. Phase Failure 3. Common Alarm 4. Future #1 5. Pump Run. B. The Common Alarm and Phase Failure relays shall be energized under normal conditions. 11. Audible Alarm Buzzer An audible alarm buzzer, capable of being heard while the motor is operating, shall operate if Fail to Start, Hardware Malfunction or any Common Alarm condition exists. 12. Manufacturer A. The controller shall be of the LMR Plus type as manufactured by Eaton Corporation. July 2011 For more information visit: PS K/E

20 AHEAD OF THE FLOW Revised 7/3/2012 Class 125 Bronze Y-Strainers Screw-in Cap Tapped Cap w/ Blow-off Plug or Solid Cap 20 Mesh SS Screen or SS Perforated Screen 125 PSI/8.6 Bar Saturated Steam to 353 F/178 C 200 PSI/13.8 Bar Non-Shock Cold Working Pressure conforms to ANSI B (NPT) or B16.18 (solder) Part 1. Body MATERIAL LIST Specification Bronze ASTM B584 Alloy C84400 (Solder) Bronze ASTM B62 Alloy C83600 (Threaded) 2. Cap Bronze ASTM B62 Alloy C Gasket PTFE 4. Screen ASTM E Mesh Stainless Steel or ASTM E674 Perforated Stainless Steel 5. Plug Brass ASTM B16 Alloy C36000 or Bronze ASTM B584 Alloy C84400 End Connection Screen Cap S- Solder Mesh (STD.) A - Tapped Cap w/plug (STD.) T - Threaded Perforated B - Solid Cap T-221/222-A Threaded T-221/222-A Threaded S-221/222-A Solder DIMENSIONS WEIGHTS QUANTITIES Dimensions Size A B C D T-221 S-221 Master In. mm. In. mm. In. mm. In. mm. In. mm. Lbs. Kg. Lbs. Kg. Ctn. Qty. ¹ ₄ / ³ ₈ / ¹ ₂ / ³ ₄ / / ¹ ₄ / ¹ ₂ / ¹ ₂ / / T-221/222-B Threaded S-221/222-A Solder S-221/222-B Solder T-221/222-B Threaded S-221/222-B Solder NIBCO INC. WORLD HEADQUARTERS 1516 MIDDLEBURY ST. ELKHART, IN USA PH: TECH SERVICES PH: FAX: INTERNATIONAL OFFICE PH: FAX:

XT SERIES Jockey Pump Controllers Features

XT SERIES Jockey Pump Controllers Features XT SERIES Jockey Pump Controllers Features XT Series Jockey Pump Controllers March 2012 1-1 XT Power Controls The XT Series of Jockey Pump Controllers incorporate Eaton s XT Power Controls which are designed

More information

catalog C-NPS-1014 NIBCO Press System

catalog C-NPS-1014 NIBCO Press System catalog C-NPS-1014 ahead of the flow NIBCO Press System Business-to-Business Solutions Look to NIBCO for technology leadership. The velocity with which e-business evolves demands that new products and

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

Figure 1: WPR2 Dimensions and Hardware

Figure 1: WPR2 Dimensions and Hardware Installation and Operation Instructions WPR2 Series (Max. Line Pressure < 300 PSI) Wet to Wet Differential Pressure Ø0.200" 2.60" 4.47" 5.47" 5.28" 3.00" Precautions Figure 1: WPR2 Dimensions and Hardware

More information

CATALOG C-NPS-0812 AHEAD OF THE FLOW. NIBCO Press System

CATALOG C-NPS-0812 AHEAD OF THE FLOW. NIBCO Press System CATALOG C-NPS-0812 AHEAD OF THE FLOW NIBCO Press System Business-to-Business Solutions Look to NIBCO for technology leadership. The velocity with which e-business evolves demands that new products and

More information

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor! PRESSURE SENSORS PRESSURE PDP3 Series 0-2 32 PDP3 Series 0-10, 0-25 34 PG Gauge Series 36 PW Wet-Wet Series (Cable Version) 38 PW Wet-Wet Series (Conduit Version) 40 PW Series Ordering Guidance 42 Selectable

More information

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 16 Stainless Steel ball valve LED light gives continuous status indication IP67 weatherproof polyamide

More information

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT SERIES Features Direct mount Full Port 316 Stainless Steel ball valve 3-piece swing out body designed for easy maintenance

More information

SANITARY PRESSURE GAUGES

SANITARY PRESSURE GAUGES 117 SANITARY PRESSURE GAUGES Type 2030 Digital Sanitary Gauge...119 Type 1032, 2 1 /2, 3 1 /2 and 4 1 /2 Gauge...120 Type 1036 3 1 /2 Gauge w/type 1037 Sanitary Fitting...121 Type 1032, 2 Fractional Gauge...122

More information

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 16 Stainless Steel ball valve LED light gives continuous status indication IP67 weatherproof polyamide

More information

Valve Selection. 1. Function and service considerations

Valve Selection. 1. Function and service considerations 1. Function and service considerations Valve Selection Selection Valves serve the purpose of controlling the fluids in building services piping. Valves are produced in a variety of design types and materials.

More information

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Mid-West Instrument. Series 700 Wet/Wet Installation and Operating Instructions. Differential Pressure Transmitter Mid-West Instrument IM_700/A Series 700 "Wet/Wet" Installation and Operating Instructions Differential Pressure Transmitter 6500 Dobry Dr. Sterling Heights, MI USA Toll Free: 800-648-5778 Ph 586-254-6500

More information

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes SERIES Features Direct mount Full Port 16 Stainless Steel ball valve 2-piece ANSI Class 150 flanged body

More information

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A Mid-West Instrument BULLETIN NO.ELEC IM121/10A Replaces IM121/09A INSPECTION Model 121 Indicating Differential Pressure Switch / Transmitter Electrical: Installation and Operating Instructions Upon receipt

More information

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 240/11 (SUPERSEDES BULLETIN NO. 240/06) Mid-West Instrument Diaphragm Type Model 240 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Field wireable

More information

Installation and Operation Instructions DLP Series

Installation and Operation Instructions DLP Series Installation and Operation Instructions DLP Series PRECAUTIONS Figure 1: DLP Dimensions and Hardware REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT WIRING WITH THE POWER APPLIED. DO NOT ALLOW

More information

February, O & M Manual for EATON FDJ Series Jockey Pump Controllers. Instruction Booklet. For more information visit:

February, O & M Manual for EATON FDJ Series Jockey Pump Controllers. Instruction Booklet. For more information visit: February, 2009 O & M Manual for EATON FDJ Series Page 2 TABLE OF CONTENTS 1. INSTALLATION AND MOUNTING OF THE CONTROLLER...3 2. SYSTEM PRESSURE CONNECTIONS...3 3. ELECTRICAL CONNECTIONS...3 3.1 ELECTRICAL

More information

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter BULLETIN NO. 220/11 (SUPERSEDES BULLETIN NO. 220/06) Mid-West Instrument Piston Type Model 220 Hazardous Locations Indicating / Non-Indicating Differential Pressure Switch or Transmitter Low cost piston

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 230523 GENERAL DUTY VALVES FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 DEFINITIONS A. The following

More information

1100 Series Piston Type Differential Pressure Gauges

1100 Series Piston Type Differential Pressure Gauges 1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

Model 124 Filter Minder & Model 124

Model 124 Filter Minder & Model 124 Installation & Maintenance Instructions Model 124 Filter Minder & Model 124 Indicating Differential Pressure Switch / Transmitter Reading Office Cutbush Park, Danehill, Lower Earley, Reading, Berkshire.

More information

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7 Features User Accessible Memory for Test Configuration Management ±0.05% FS System Accuracy EU Throughput Rates of 500 Hz Auto-Negotiating 10/100 BaseT Ethernet with TCP & UDP Protocol Pressure Ranges

More information

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators VA-640GSX024P Datasheet Large Globe Actuators Overview The VA-640GSX024P Electronic valve actuators receive a 0 to 10 VDC or 4 to 20 ma control signal to proportionally control the valve. Applications

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen Measurement System with Air Blast Cleaner Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting

More information

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O Diaphragm Type Differential Pressure Gauge & Switch BULLETIN NO. 130/11 (SUPERSEDES BULLETIN NO. 130/02) is a rugged general purpose differential pressure gauge with a 4-1/2" round dial. Common Applications:

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.

More information

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit:   Mid-West Instrument PISTON STYLE GAUGE For Installation and Operation Manuals Please Visit: www.midwestinstrument.com/literature Mid-West Instrument BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

SECTION INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

SECTION INSTRUMENTATION AND CONTROL DEVICES FOR HVAC PART 1 GENERAL 1.01 SECTION INCLUDES A. Air supply system. B. Thermostats. C. Humidistats. D. Control valves. E. Automatic dampers. F. Damper operators. G. Miscellaneous accessories. 1.02 RELATED REQUIREMENTS

More information

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PRESSURE TRANSDUCERS. Specifications. Individual Specifications 00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need

More information

PRESSURE BENCH OPERATING INSTRUCTIONS

PRESSURE BENCH OPERATING INSTRUCTIONS PRESSURE BENCH OPERATING INSTRUCTIONS Overview: The pressure bench system allows the user to apply a variety of calibrated pressures to a variety of high and low pressure transducers. In addition the system

More information

PISTON STYLE GAUGE. Mid-West Instrument

PISTON STYLE GAUGE. Mid-West Instrument PISTON STYLE GAUGE Mid-West Instrument 1 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 A low cost differential

More information

VSO Thermally Compensated Proportional Valve

VSO Thermally Compensated Proportional Valve 4 VSO Thermally Compensated Proportional Valve Typical Applications Gas Chromatography Mass Spectrometry Ventilators O 2 Concentrators/Conservers Anaesthesia Delivery & Monitors Pressure & Control Mass

More information

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PRESSURE TRANSDUCERS. Specifications. Individual Specifications GEMS COMPLIANT 00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 00 psi to 0-0,000 psi ranges (0- bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For

More information

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the

More information

Miniature Proportional Valve Thermally Compensated Proportional Valve. Physical Properties

Miniature Proportional Valve Thermally Compensated Proportional Valve. Physical Properties VSO Miniature Proportional Valve Thermally Compensated Proportional Valve Typical Applications Gas Chromatography Mass Spectrometry Ventilators O 2 Concentrators/Conservers Anaesthesia Delivery & Monitors

More information

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Installation The VDS-1000 combines either two (2) low voltage, high side or low side, switched outputs

More information

General Service Gauges

General Service Gauges Utility HVAC Diaphragm General Service Gauges The Weiss Series TL Gauges are intended for general service conditions, for pressure or vacuum on air, oil, water, gas or other mediums that do not attack

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

O.E.M GAUGES. For Installation and Operation Manuals Please Visit: Mid-West Instrument

O.E.M GAUGES. For Installation and Operation Manuals Please Visit:   Mid-West Instrument O.E.M GAUGES For Installation and Operation Manuals Please Visit: www.midwestinstrument.com/literature Mid-West Instrument Product Notes: BULLETIN NO. 126-127/11 (SUPERSEDES BULLETIN NO. 126-127/00) O.E.M

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

Hose Length Custom Length Supply Line Options Ball Valve w/ PT UBY Strainer w/ PT and BDV

Hose Length Custom Length Supply Line Options Ball Valve w/ PT UBY Strainer w/ PT and BDV Model AC Circuit Sentry Automatic Balance Hose Kits - Submittal Hose Kit Size Flow Range *MFR Qty. 1/2".33-14 5 3/4".33-14 11 3/4" 5-50 11 1".33-14 20 1" 5-50 20 1-1/4" 5-50 30 **1-1/2" 5-50 44 **1-1/2"

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH 331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing

More information

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment CLARK SOLUTIONS 400 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches 1,2 & 3 Switch output, Adjustable Ranges 30 Vac to 6000 PSI, -180 to 650 o F DESCRIPTION The 400 Series is a versatile family

More information

CATALOG C-NPS-0618 AHEAD OF THE FLOW NIBCO. Press System

CATALOG C-NPS-0618 AHEAD OF THE FLOW NIBCO. Press System CATALOG C-NPS-0618 AHEAD OF THE FLOW NIBCO Press System Business-to-Business Solutions Look to NIBCO for technology leadership. The velocity with which e-business evolves demands that new products and

More information

FIELD DEVICES CONTROLLERS

FIELD DEVICES CONTROLLERS FIELD DEVICES CONTROLLERS Product Specifications 43AP Pneumatic Indicating Controllers These instruments indicate and control pressure, temperature, vacuum, and differential pressure. They provide process

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

Pressure Instrument Testing Equipment

Pressure Instrument Testing Equipment Pressure Instrument Testing Equipment BULLETIN TE-1 A Halliburton Company A Durable, Portable Primary Standard Model 1305D Deadweight Tester The Ashcroft 1305D Deadweight Tester is an affordable, portable

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

COUNTER CLOCKWISE FOR CLARITY (SEE MANUAL FOR SPECIFIC WATER & DUST TIGHT AP LOCAL ELEMENT ENCLOSURE ROTA FLAT PARALLEL TO FLOW.

COUNTER CLOCKWISE FOR CLARITY (SEE MANUAL FOR SPECIFIC WATER & DUST TIGHT AP LOCAL ELEMENT ENCLOSURE ROTA FLAT PARALLEL TO FLOW. U-LENGTH HORIZ ORIENTA SHOWN ENCLOSURE MEETS WATER & DUST TIGHT AP (SEE MANUAL FOR SPECIFIC A LOCAL ELEMENT ENCLOSURE ROTA COUNTER CLOCKWISE FOR CLARITY 9.85 (250.2) 1" NPT X" 3.00 (76.2) LC OPTIONAL DISPLAY

More information

Model 550 Series Vibration Switches

Model 550 Series Vibration Switches OPERATION MANUAL Vibration Switches Includes: 550 550M 550-X 550M-X Page 2 SECTION TITLE PAGE 1. INTRODUCTION... 2 2. FEATURES... 3 3. WIRING... 4 4. ANALOG METER... 4 5. TESTING... 4 6. INSTALLATION...

More information

825-P Modular Protection System for motors Specification Guide

825-P Modular Protection System for motors Specification Guide Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection

More information

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

TEK-B AR 3110A. Differential Pressure Transmitter.   Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE Technology Solutions TEK-B AR 3110A Differential Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Bar 3110A Differential

More information

Type A-10 General Purpose Pressure Transmitter

Type A-10 General Purpose Pressure Transmitter General Purpose TRONIC > General Purpose > A-10 Type A-10 General Purpose Pressure Transmitter Standard Features Signal output: 4-20 ma 2-wire or 0-10 V 3-wire Supply voltage: 8-30 DC (14-30 VDC) Process

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Iron Check Valves Illustrated Index

Iron Check Valves Illustrated Index Iron Check Valves Illustrated Index Iron Body Swing Check Valve Bronze Mounted or All Iron 125 lb. SWP 200 lb. CWP Iron Body Swing Check Valve Bronze Mounted 250 lb. SWP 500 lb. CWP Iron Body Silent Check

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120 BULLETIN NO. 120/11 (SUPERSEDES BULLETIN NO. 120/02) Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the pressure drop across

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123 BULLETIN NO. 123/11 (SUPERSEDES BULLETIN NO. 123/03) Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the pressure drop across

More information

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device 2SGT Electronic Pressure Instrument Three Separate Functions in a Single Loop-Powered Device Switch Two Independent, Programmable SPST Solid State Relays Program switch open and close values in engineering

More information

Model FVP General Specification. Flanged Vortex Plate. Product Features

Model FVP General Specification. Flanged Vortex Plate. Product Features Flanged Vortex Plate Product Features Our Inline meters can measure Steam, Gases or Liquids. Measures two times lower than any other Vortex Meter. Heavy Duty & Maintenance Free Design C&C Machined from

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

ATevo SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. O.: C3700-L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3700-L 298-29, GODA-RO, GUPO-SI, GYEOGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124 BULLETIN NO. 124/12 (SUPERSEDES BULLETIN NO. 124/11) Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters A low cost differential pressure gauge for use in measuring the

More information

NV Direct Coupled Globe Valve Actuator

NV Direct Coupled Globe Valve Actuator 70396 Rev. C Non-spring return, on/off, floating point, proportional control NV Direct Coupled Globe Valve Actuator NV24-3 US NVD24-3 US NV24-MFT US NVD24-MFT US Application For on/off, floating point

More information

North American Automatic Manual Reset and Motorized Valves

North American Automatic Manual Reset and Motorized Valves Combustion North American Automatic Manual Reset and Motorized Valves 1516 Manual Reset 1517 Motorized 1516/1517 Automatic Oil Shutoff Valves Agency approvals: UL, FM, CSA Proof-of-Closure Switch High

More information

Signet 2551 Magmeter Flow Sensor

Signet 2551 Magmeter Flow Sensor Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No

More information

NETSIAN TECHNOLOGY VALVE SCHEDULE

NETSIAN TECHNOLOGY VALVE SCHEDULE NETSIAN TECHNOLOGY VALVE SCHEDULE JOB NAME: St. Joe's Hospital - Sonntag Academic Pavilion Date: 10-19-11 1911 CALC. Cv FLOW @ VALVE CAPACITY 14 1.4 ACTUAL PRESS. VALVE SIZE GPM or PSI PRESS VALVE DROP

More information

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a single phase, on-line, double conversion, solid state

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan. 57 574 4 574 573 57 57 57 57 1 571 47 474 4 474 473 47 47 47 47 1 471 56 567 7 565 565 37 374 74 374 7 373 37 37 37 37 1 371 467 6 467 465 465 7 74 4 74 73 7 7 7 7 7 71 71 36 367 7 365 365 6 67 7 65 65

More information

Instructions for Installation, Operation, Care and Maintenance

Instructions for Installation, Operation, Care and Maintenance Bulletin 59 Model DDX Deluge Valve (50 mm), ½ (65 mm), (80 mm), 76 mm, 4 (00 mm), 6 (50 mm), 65 mm & 8 (00 mm) Bulletin 59 Instructions for Installation, Operation, Care and Maintenance Wet Pilot Line,

More information

Bourdon Tube Pressure Switches

Bourdon Tube Pressure Switches DA /DS Bourdon Tube es Visible setpoint, adjustable deadband, snap action switch pressure ranges to 000 psi Weather-Proof Types DAW, DSW, DRW -/1 2-1/1 REAR MOUNTING FLANGE ().20 DIA. HOLES AT 120 ON -1/2

More information

Series Electric Actuators

Series Electric Actuators Electric Actuators Electric Actuators Series 44000 Electric Actuators ELECTRIC ACTUATORS With maintenance-free operation, the Crane 44000 electric actuator is ideal for small to medium diameter valves

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

IM K IM K. Instructions for Cutler-Hammer Jockey Pump Controllers

IM K IM K. Instructions for Cutler-Hammer Jockey Pump Controllers IM05805004K IM05805004K Instructions for Cutler-Hammer Jockey Pump Controllers IM05805004K Page i TABLE OF CONTENTS 1. INSTALLATION AND MOUNTING OF THE CONTROLLER... 1 2. SYSTEM PRESSURE CONNECTIONS...

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview Product Description The MediaGauge MG-MD is a multi-functional digital pressure gauge consisting of a media isolated piezoresistive pressure sensing element, signal conditioning circuitry for temperature

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Electronic Pressure Measurement WIKA Datasheet PSD-10 Applications Hydraulics and pneumatics Filter monitoring Pump control

More information

Hot Tap Insertion Vortex

Hot Tap Insertion Vortex Hot Tap Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 48 Heavy Duty & Maintenance Free Design

More information

Type A-10 General Purpose Pressure Transmitters

Type A-10 General Purpose Pressure Transmitters Type A-10 General Purpose Pressure Transmitters Applications Mechanical engineering Machine tools Process control and automation Hydraulics and pneumatics Pumps and compressors Special Features Pressure

More information

EVO AT SERIES BATTERY CHARGER

EVO AT SERIES BATTERY CHARGER EVO AT SERIES BATTERY CHARGER AT SERIES BATTERY CHARGER P R O D U C T PATENT PENDING hindlepowerinc.com 610-330-9000 Evo AT Series battery charger designed with YOU in mind. Evo AT Series battery charger

More information

Power Switching Devices

Power Switching Devices Watlow has manufactured solid state power controllers for over forty years. Watlow s is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier

More information

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951

More information

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications PART 1 GENERAL 1.1 SUMMARY A. This specification describes a stand-by, three-phase, solid state Lighting Inverter System

More information

FlowCon Energy FIT System

FlowCon Energy FIT System Energy FIT System Energy-Saving Pressure and Temperature Independent System 65-250 mm / 2 1/2-10 SPECIFICATIONS PICV valve: Static pressure: 4000 kpa / 580 psi Ambient temperature: -10 C to +50 C / +14

More information

SECTION (15110) - GENERAL DUTY VALVES FOR PLUMBING PIPING

SECTION (15110) - GENERAL DUTY VALVES FOR PLUMBING PIPING SECTION 22 05 23 (15110) - GENERAL DUTY VALVES FOR PLUMBING PIPING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Valves. B. Related Sections: 1.02 REFERENCES 1. Section 22 05 53 (15075) Identification

More information

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves.

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves. Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

P445 Series Electronic Lube Oil Control

P445 Series Electronic Lube Oil Control FANs 125, 121 s Section P Product/Technical Bulletin P445 Issue Date 0100 P445 Series Electronic Lube Oil The P445 Series Electronic Lube Oil is designed for use on refrigeration compressors equipped with

More information