VIESMANN. Installation instructions VITOTROL 100. for contractors. Vitotrol 100 Type UTDB
|
|
- Benjamin Chapman
- 6 years ago
- Views:
Transcription
1 Installation instructions for contractors VIESMNN Vitotrol 100 Type UTD Room temperature controller with digital time switch Part no: , VITOTROL 100 7/2009
2 Safety instructions Please follow these safety instructions closely to prevent accidents and material losses. Safety instructions explained Danger This symbol warns against the risk of injury. Note Details identified by the word "Note" contain additional information. Target group Working on the system Isolate the system from the power supply and check that it is no longer 'live', e.g. by removing a separate fuse or by means of a mains isolator. Safeguard the system against unauthorised reconnection. When using gas as fuel, also close the main gas shut-off valve and safeguard against unauthorised reopening. These instructions are exclusively designed for qualified personnel. Work on gas appliances must only be carried out by a qualified gas fitter. Work on electrical equipment must only be carried out by a qualified electrician. Regulations Observe the following when working on this system all legal instructions regarding the prevention of accidents, all legal instructions regarding environmental protection, the ode of Practice of relevant trade associations, all current safety regulations as defined by DIN, EN, DVGW, TRGI, TRF, VDE and all locally applicable standards. 2
3 Index Preparing for installation Installation location... 4 Installation sequence Opening the Vitotrol Fitting the wall mounting base... 5 Electrical connection to the control unit... 6 onnection at the control unit with plug lh... 7 onnection at the control unit with terminal "X1"... 8 onnection at the control unit with plug gh... 9 onnection at the control unit with plug a-d... 9 onnection at the control unit with plug "N2" onnection at the control unit with terminal "X3" onnection at the control unit with terminal strip Electrical connection at the pump/mixer onnecting the heating circuit pump onnecting the mixer motor Replacing a control unit RT or clock thermostat F ssembling the Vitotrol ommissioning Specification
4 Installation location Installation in the main living room on an internal wall opposite radiators pprox. 1.5 m from the floor Not near windows and doors Not on shelves or in recesses Not near heat sources (radiators, direct sunlight, fireplace, TV set etc.) Do not install further controllers in this main living room. Open any thermostatic radiator valves fully. 4
5 Opening the Vitotrol Fitting the wall mounting base Power is supplied by batteries (see chapter "Specification"). For the connection to the control unit, see the following chapter. 5
6 Fitting the wall mounting base (cont.) Electrical connection to the control unit Note Press cables flat into the base. 6
7 Electrical connection to the control unit (cont.) onnection at the control unit with plug lh Recommended connecting cable 2-core cable with a cross-section of 1.5 mm for 230 V~ 96 N? L 1 Vitotrol 100, type UTD Plug lh to the control unit Remove the jumper when making this connection onnection at the external extension H4 X4.3 X4.2 X4.1 24V- X2.2 X2.1 X V~ N? L 1 96 Vitotrol 100, type UTD 7
8 Electrical connection to the control unit (cont.) External extension H4 for Vitopend and Vitodens Plug lh to the control unit Recommended connecting cable 2-core cable with a cross-section of 0.75 mm² for low voltage onnection at the control unit with terminal "X1" X1 1 L N Vitotrol 100, type UTD Terminals "X1" on the control unit The Vitotrol 100 switches the heating circuit pump or the burner. Remove the jumper when making this connection Recommended connecting cable 2-core cable with a cross-section of 1.5 mm for 230 V~ 8
9 Electrical connection to the control unit (cont.) onnection at the control unit with plug gh Recommended connecting cable 2-core cable with a cross-section of 1.5 mm for 230 V~ 56 N L LRLS Vitotrol 100, type UTD Plug gh to the control unit Remove the jumper when making this connection onnection at the control unit with plug a-d The Vitotrol 100 switches the heating circuit pump or the burner. Recommended connecting cable 2-core cable with a cross-section of 0.75 mm² for low voltage 103 Vitotrol 100, type UTD Plug a-d to the control unit Remove the jumper when making this connection 9
10 Electrical connection to the control unit (cont.) onnection at the control unit with plug "N2" N 2? L N 1 L N Vitotrol 100, type UTD Plug "N2" at the control unit Remove the jumper when making this connection Recommended connecting cable 2-core cable with a cross-section of 1.5 mm for 230 V~ onnection at the control unit with terminal "X3" X Vitotrol 100, type UTD The Vitotrol 100 switches the heating circuit pump or the burner. 10 Terminals "X3" on the control unit Recommended connecting cable 2-core cable with a cross-section of 0.75 mm² for low voltage
11 Electrical connection to the control unit (cont.) onnection at the control unit with terminal strip Vitotrol 100, type UTD Terminal strip inside the control unit Subject to function, remove jumper : Terminals 4 and 5: The Vitotrol 100 switches the heating circuit pump. Terminals 9 and 10: The Vitotrol 100 switches the burner. Remove the jumper when making this connection Recommended connecting cable 2-core cable with a cross-section of 1.5 mm² Note There is no frost protection when the burner is switched OFF. 11
12 Electrical connection at the pump/mixer onnecting the heating circuit pump The Vitotrol 100 controls the room temperature by starting and stopping the heating circuit pump. G L1 N PE F E D M 1~ Vitotrol 100, type UTD The contact setting corresponds to heating circuit pump "OFF" Heating circuit pump Danger Incorrect core termination can cause severe injuries and damage to the equipment. Take care not to interchange wires "L1" and "N". D Fuse, 6 E Main isolator F Fuse, max. 16 G Power supply 230 V~ Note The supply cable to the Vitotrol 100 must additionally be protected with a 6 fuse. Recommended connecting cable 2-core cable with a cross-section of 1.5 mm² for 230 V 12
13 Electrical connection at the pump/mixer (cont.) onnecting the mixer motor The Vitotrol 100 controls the room temperature by opening and closing the mixer. L1 G N PE F E D X X1 M 1~ Vitotrol 100, type UTD The contact position corresponds to mixer "lose" Mixer motor hange the rotational direction of the mixer motor, if required: Re-plugging the socket strip from plugin strip X1 to X2 or Rotating the plug by 180 Danger Incorrect core termination can cause severe injuries and damage to the equipment. Take care not to interchange wires "L1" and "N". D Fuse, 6 E Main isolator F Fuse, max. 16 G Power supply 230 V~ Recommended connecting cable 2-core cable with a cross-section of 1.5 mm for 230 V~ Note The supply cable to the Vitotrol 100 must additionally be protected with a 6 fuse. 13
14 Replacing a control unit RT or clock thermostat F Upon heat demand, the contact switches from "" to "". onnection of the components to be switched at contacts "" and "". L1 N M 1~ N L1 M 1~ ontrol unit RT or lock thermostat F omponents to be switched Vitotrol 100, type UTD omponents to be switched 14
15 ssembling the Vitotrol
16 ommissioning 1. Open flap. 2. Use a pointed object to press reset. 3. Select language with v/v. 4. onfirm with OK. 5. Set current time and date with v/ V. 6. onfirm with OK. 16
17 Specification Rated voltage 3 V attery LR 6/ Rated breaking capacity of the zero volt contact max. 6(1), 230 V~ min. 1 m, 5 V mbient temperature during operation 0 to 40 during storage and transport -25 to 65 IP rating IP 20 Protection class II Terminals suitable for the following cables solid, single core cables up to 2.5 mm² flexible cables up to 2.5 mm² 17
18 18
19 19
20 Printed on environmentally friendly, chlorine-free bleached paper 20 Viessmann Werke GmbH&o KG D llendorf Telephone: Fax: Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, G Telephone: Fax: info-uk@viessmann.com Subject to technical modifications.
VIESMANN. Installation instructions VITOSOL-F. for contractors
Installation instructions for contractors VIESMANN Vitosol-F Type SV and SH Flat-plate collector for installation on supports and wall mounting VITOSOL-F 9/2010 Dispose after installation. Safety instructions
More informationVIESMANN. Installation instructions VITOFLAME 300. for contractors
Installation instructions for contractors VIESMANN Vitoflame 300 Type VHG III Pressure-jet oil burner for the Vitorondens 200-T, 67.6 to 107.3 kw VITOFLAME 300 2/2012 Dispose after installation. Safety
More informationVIESMANN VITOTRANS 100 Plate heat exchanger
VIESMANN VITOTRANS 100 Plate heat exchanger Datasheet Part numbers and prices: see pricelist VITOTRANS 100 Type PWT For transfer stations from heat supply networks, for system separation in heating systems
More informationVIESMANN. Installation instructions VITOSOL 200. for heating engineers. Vitosol 200 Type SD2 Direct flow vacuum tube collector
Installation instructions for heating engineers VIESMANN Vitosol 200 Type SD2 Direct flow vacuum tube collector VITOSOL 200 5/2005 Dispose after installation. Safety instructions Please follow these safety
More informationVIESMANN. Installation instructions VITOSOL 300-T. for contractors. Vitosol 300-T Type SP3A Vacuum tube collector based on the heat pipe principle
Installation instructions for contractors VIESMANN Vitosol 300-T Type SP3A Vacuum tube collector based on the heat pipe principle VITOSOL 300-T 9/2009 Dispose after installation. Safety instructions Please
More informationVIESMANN. Installation instructions VITOSOL 200-T. for contractors. Vitosol 200-T Type SP2 Vacuum tube collector based on the heat pipe principle
Installation instructions for contractors VIESMANN Vitosol 200-T Type SP2 Vacuum tube collector based on the heat pipe principle VITOSOL 200-T 6/2010 Dispose after installation. Safety instructions Please
More informationVIESMANN VITODENS 222-F
VISMNN VITONS 222- atasheet or part no. and prices: see pricelist VITONS 222- Type 2T as condensing storage combi boiler, 3.2 to 35. kw for natural gas and LP VITONS 222- Type 2S as condensing storage
More informationVIESMANN. VITOMAX 100-HS High pressure steam boiler Steam output 1.0 to 6.4 t/h. Datasheet. VITOMAX 100-HS Type M33A. Part no. and prices on request
VIESMANN VITOMAX 100-HS High pressure steam boiler Steam output 1.0 to 6.4 t/h Datasheet Part no. and prices on request VITOMAX 100-HS Type M33A Oil/gas high pressure steam boiler Compliant with the requirements
More informationVIESMANN. Datasheet Part no.: see pricelist, price upon request Not suitable for sizing the boiler. For this, see the separate technical guide.
VIESMANN VITOMAX 200 HW Hot water boilers for permissible flow temperatures in excess of 120 C Three-pass boiler Combustion output 4.0 to 18.2 MW Datasheet Part no.: see pricelist, price upon request Not
More informationFor commissioning, maintenance and function checks of solar thermal systems Part no
Operating instructions Solar service case For commissioning, maintenance and function checks of solar thermal systems Part no. 7248 299 Contents of the case A Compass B Information labels C Service labels
More informationVIESMANN VITORONDENS 200-T Oil Unit condensing boilers 20.2 to kw
VISMANN VITORONDNS 200-T Oil Unit condensing boilers 20.2 to 107. kw Datasheet Part no. and prices: see pricelist VITORONDNS 200-T Type BR2A 20.2 to 5.7 kw Cast iron low temperature oil boiler with condensing
More informationFAST-STAT. Model 3000 Installation Instructions. Application. Troubleshooting not operating. Before Installing This Product. Sender Installation
Model Installation Instructions Application The Model is designed to add additional control wiring between the thermostat and indoor unit or between the indoor unit and outdoor unit. Before Installing
More informationWilo-Control SC-Fire Jockey
Pioneering for You Wilo-Control SC-Fire Jockey de en fr Einbau- und Betriebsanleitung Installation and operating instructions Notice de montage et de mise en service nl Inbouw- en bedieningsvoorschriften
More informationInstallation Instructions. Vitosol 100. Vitosol 100 Type w 2.5 Flat collector for flat roofs and freestanding installation Part No.
Installation Instructions Vitosol 100 Type w 2.5 Flat collector for flat roofs and freestanding installation Part No. 3001 970 Vitosol 100 8/99 Safety instructions This hazard symbol precedes all important
More information- Wiring Brochure Universal Reset Module 422e
- Wiring Brochure Universal Reset Module 422e W 422e 01/08 1 Information Brochure hoose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in
More informationINTELLIGENT SOLAR MODULE ISM 1
INTELLIGENT SOLAR MODULE ISM 1 INSTALLATION & USER INSTRUCTIONS FOR USE WITH THE FOLLOWING APPLIANCES AND ACCESSORIES: CDI SYSTEM OILER FITTED WITH OPTIONAL INTEGRAL DIVERTER VALVE FR110 PROGRAMMALE ROOM
More informationInstallation manual portable distributors
EN Installation manual portable distributors EN 60003206 Issue 11.2016 15/11/2016 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2 Intended
More informationMAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS
MAKING MODERN LIVING POSSIBLE UniLynx Indoor Installation Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 Installation Sequence 2 Important
More informationGEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds
Venetian blind motor: GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds DE FR ES IT Original-Montage- und Betriebsanleitung Original assembly and operating instructions Notice
More informationTLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual
RESOL TLR2 Mounting Connection Handling Fault localization *48001550* 48001550 TLR2 Thanks for buying a RESOL product. Read this manual carefully to get the best perfomance from this unit. B Manual www.resol.de
More informationInstallation manual wall-mounted distributor
EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2
More informationOperatingmanual. Mehrsprachige Anleitung unter Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING.
Operatingmanual Mehrsprachige Anleitung unter www.benning.de Multilingual manuals at TRITEST pro TRITEST pro D F 8 9 J 1 2 3 6 7 4 5 TRITEST pro T.-Nr: 10115280.01 Stand: 10-2014 10/ 2014 TRITEST pro Operating
More informationOperating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN
Operating instructions Rotary actuators M135 M140 M150 M180 June 2012 / 118614 / EN General information General information Proof of amendment Copyright Subject to alterations Manufacturer Version Date
More information- Wiring Brochure Universal Reset Module 422
- Wiring Brochure Universal Reset Module 422 W 422 03/09 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More informationRESOL SBS 1000 * * Connection Operation
RESOL SBS 1000 Connection Operation FlowCon SBS 1000 A www.resol.de *48003820* 48003820 Thank you for buying this RESOL product. Please read this manual carefully to get the best performance from this
More informationVIESMANN. Product parameters Product range Datasheet
VIESMANN Product parameters Product range 2013 Datasheet Productspecific parameters for calculating the energy efficiency requirement in building regulations Part L1 and L2 11/2013 Product parameters Introduction:
More informationInstruction Manual for Globe Price Computing Scale Models GS30 and GS30T
Model GS30 Model #: Serial #: Model GS30T NTEP Approved Meets NIST Handbook 44 Criteria Legal for Trade Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T For Service on Your Scale:
More informationRO Automatic trailer coupling. Repair instructions. 5KPVM02000 Towing Hitch Automatic Rockinger RO244A
utomatic trailer coupling Repair instructions 5KPVM02000 Towing Hitch utomatic Rockinger RO244 5KPVM02010 Towing Hitch utomatic Rockinger foot operated RO244L Contents 1 General Validity and application
More informationInstallation and Operating Instructions Electric Vibrators HV/VFL Series
Installation and Operating Instructions Electric Vibrators HV/VFL Series Original Instruction Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 463081 Telefax +49 821 463084
More informationInstruction Manual. Sewage lifting station compli 300
Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803
More informationSolar Controller SUNGO S
OPERATING INSTRUCTIONS, Issue SW1201/ 2.01/ HW2.4 Solar Controller SUNGO S Wagner& Co Figure 1 Solar Controller SUNGO S. The benefits at a glance Large display to indicate temperature, balance values and
More information8.50 Kampmann Equestrian Solarium Perfect Enhances the Vital Functions and the Immune System Table of Contents.
1.26 1.45 8.50 Kampmann Equestrian Solarium Perfect Table of Contents Table of Contents 1.26 1.46 1. Correct and Proper Use.......................................... 3 1.1 Personal Qualification 1.2 Limits
More informationOperating Instructions
Operating Instructions BE2700 Brinkmann Immersions pumps of the series TA/STA/TAL/SAL901... 1303 Contents 1 General...1 2 Safety...2 3 Transport and storage...2 4 Description of product and accessories...2
More informationOperating instructions Flow monitors SI / / 2010
Operating instructions Flow monitors SI5004 UK 704339 / 02 08 / 2010 Contents 1 Safety instructions 3 2 Functions and features 4 2.1 Application area 4 2.2 Operating principle flow monitoring 4 3 Installation
More informationGEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds
Motor for Venetian blinds: GEIGER GJ56.. AIR (GJ56.. F03) for Venetian blinds DE FR ES IT Original-Montage- und Betriebsanleitung Original assembly and operating instructions Notice originale de montage
More informationCM707 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET
CM707 PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET The CM707 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It can be used
More informationCompact System NRGS 11-2 NRGS Original Installation Instructions English
Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive
More informationGEIGER-GJ56.. For Venetian blinds and exterior blinds
Venetian blind motor: GEIGER-GJ56.. For Venetian blinds and exterior blinds DE FR ES IT Original-Montage- und Betriebsanleitung Original installation and operating instructions XXX Manuel d utilisation
More informationOperating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50
Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50 AK-Ex with electric actuator II 2G c II TX II 2D c II T 80 C AK-Ex with pneumatic actuator II 2G c IIB TX
More informationDeltaSol AX * *
DeltaSol X Differtial temperature controller Manual for the specialised craftsman Installation Operation Functions and options Troubleshooting *48000250* 48000250 Thank you for buying this RESOL product.
More informationDeltaSol AX. RESOL DeltaSol AX * * Mounting Connection Operation Application examples. manual
RESOL DeltaSol AX Mounting Connection Operation Application examples DeltaSol AX *48000250* 48000250 Thank you for buying a RESOL product. Please read this manual carefully in order to put this controller
More informationInstallation Instructions for direct line voltage connection / Basic / SubstiTUBE Value Advanced ST8-HV / ST8-HB / ST8-HA
www.osram.com/substitube Installation Instructions for retrofitting a and direct line voltage connection Value Advanced ST8-HV / ST8-HB / ST8-HA / Basic / 1. Installation options 1. Installation options
More informationECONOMISER SERIES E2T USER MANUAL
TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014
More informationSafety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.
27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety....
More informationOperating instruction and technical description
Operating instruction and technical description EV Simulator for charging devices with charging plug / charging coupler / charging cable type 1 and type 2 as service case Photo: EV simulator/tester with
More informationDigital Room THERMOSTAT for Model No. RT300
Instruction Manual Sales +44 (0) 8700 766900 Technical +44 (0) 8700 766902 Salus Controls plc Enterprise Park, Bala Gwynedd, LL23 7NL Regional offices, England & Scotland. Web: www.salus-tech.com Email:
More informationManual. BlueSolar Grid Inverter 1500 / / / / / 230
Manual EN BlueSolar Grid Inverter 1500 / 230 2000 / 230 2800 / 230 4000 / 230 5000 / 230 Before you start This manual contains important information regarding installation and safe operation of this unit.
More informationCM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET
CM707 (UK Version) PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET The CM707 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It
More informationSection 1.0 Warnings Section 2.0. Section 3.0. Section 4.0. MCD3000 Inside Delta Connection Kits. Contents
Section 1.0 Warnings... 2 Section 2.0 Description 2.1 Overview... 3 2.2 Inside delta ratings... 3 2.3 Isolation... 3 2.4 Supply voltage... 3 Contents Section 3.0 Section 4.0 Kit Installation 3.1 Overview...
More informationOPERATING INSTRUCTIONS
Conveyor Belt Misalignment Switch Type MRS 001 Device Identification No.: 91.055 301.001 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national
More informationOPERATING INSTRUCTIONS
Emergency Cord Switch Type PRS Device identification No.: 91.054 033.001, /.101 and /.201 OPERATING INSTRUCTIONS 2 CE Sign and Conformity The device meets the requirements of the valid European and national
More informationOPERATING INSTRUCTIONS
Emergency Cord Switch Type LRS 004 Device identification no.: 93.046 690.004 OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations.
More informationThese operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800
Original instructions Operating Instructions for May 2010 Electric Internal Vibrators BA No. 1092E Series NCX and NCZ These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ
More informationEasy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH
STANDBY POWER FURNACE SWITCH Easy/Tran TF Congratulations on your purchase of the Reliance Controls Easy/Tran TF furnace transfer switch. Reliance has been manufacturing transfer switches and equipment
More informationSafety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15
17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas
More informationD58 Series Brake Instructions
D58 Series Brake Instructions 4740 W. Electric Avenue Milwaukee, WI 53219 414/672-7830 FAX 414/672-5354 www. dingsbrakes.com Safety information 2 Safety information 2.1 Persons responsible for the safety
More informationInstruction Manual for Globe Price Computing Scale Models GS30 and GS30T
Model GS30 Model #: Serial #: Model GS30T NTEP Approved Meets NIST Handbook 44 Criteria Legal for Trade Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T For Service on Your Scale:
More informationGEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply
Venetian blind motor: GEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply DE FR ES IT Original-Montage- und Betriebsanleitung Original assembly and operating
More informationGEIGER-SOLIDline* GEIGER-Touch (GU45..M) for rolling shutters, awnings and screens. Bedienungsanleitung. Operating Instructions. Manuel d utilisation
Tubular motor: GEIGER-SOLIDline* Motor control: GEIGER-Touch (GU45..M) for rolling shutters, awnings and screens DE Bedienungsanleitung Operating Instructions FR Manuel d utilisation ES Manual de instrucciones
More informationOperating instructions Flow monitors SI6600 SI6700 SI /02 01/2011
Operating instructions Flow monitors SI6600 SI6700 SI6800 UK 704680/02 01/2011 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 3 3 Functions and features 4 3.1 Application
More informationDA/CL 74C Gear Motor and PCB
/L 74 Gear Motor and P Technical User Guide English: For other language variants of this document we refer to: Español: Para otras variantes del idioma de este documento, visite: Français: Pour les versions
More informationWireless Digital Room Thermostat with Night Set-Back
Wireless Digital Room Thermostat with Night Set-Back Model: TRT047N Installation & Operating Instructions 1. General Information These instructions should be read carefully and retained for further reference
More informationOPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13
OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13 v1.5 07.07.2011 Table of contents 1. Safety measures... 2 2. Phase spin direction test... 3 3. Motor shaft spin direction (using
More informationMicro Diaphragm Gas Sampling Pumps
Operating and Installation Instructions Micro Diaphragm Gas Sampling Pumps Type range: NMP 03 KP DC-B1 NMP 03 KP DC-S NMP 03 KP DC-B3 NMP 03 KP DC-M NMP 03 KP DC-L You have selected a high-quality KNF
More informationModule B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN
Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN 05-2018 ELECTRIC DEVICE UNDER VOLTAGE! Before any action related to the power supply (cables connection, device
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies
Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain
More informationEN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3
EN Operating manual Motorised zone valve Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 This manual ensures safe and efficient use of the 3PV2 or 3PV8 force-actuated three-way valve with spring-loaded return
More informationGEIGER-SoftPerfection (GR45..E03) for rolling shutters with stoppers and anti-lift device
Tubular Motor: GEIGER-MODULARline Motor Control: GEIGER-SoftPerfection (GR45..E03) for rolling shutters with stoppers and anti-lift device DE FR ES IT Bedienungsanleitung Operating Instructions Manuel
More informationSolar Thermal Energy Flat & Tube Panel Standard Kits Installation Overview
Solar Thermal Energy Flat & Tube Panel Standard Kits Installation Overview Viessmann As a world leader in heating technology, Viessmann has 30 years experience in renewable energy systems and there are
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies
Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...
More informationDifferential Pressure Control Valve
Differential Pressure Control Valve www.ballorex.com 2 Table of contents Chapter Ballorex Delta DHC DN 15-150 1. Safety instructions 4 1.1 Rules/regulations 4 1.2 Intended use 5 1.3 Initial operation 5
More informationSolar Thermal. Grant Solar Pump Station Installation & Servicing Instructions
Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant
More informationSolar Controller SUNGO S
OPERATING INSTRUCTIONS, Issue 1201/2.4 Solar Controller SUNGO S Wagner& Co Figure 1 Solar Controller SUNGO S The benefits at a glance Large illuminated display to indicate temperature, balance values and
More informationLEAD ACID BATTERY CHARGER
LEAD ACID BATTERY CHARGER MODEL NO: LA4 & LA6 OPERATION & MAINTENANCE INSTRUCTIONS LS1214 INTRODUCTION Thank you for purchasing this CLARKE Battery Charger. Please read this manual thoroughly, before attempting
More informationOperating and Installation Instructions Diaphragm Vacuum Pumps and Compressors
Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected
More informationNEW EFD fuse disconnector
NEW EFD fuse disconnector More space for finger to open fuse carrier Advantages of cylindrical fuse disconnector EFD ompliance with IE 60947-1, IE 60947-3, UL 4248-1, UL 4248-4, UL 4248-8, UL 486E and
More informationInstallation and Start-up Guide. ACS-BRK Brake Units
Installation and Start-up Guide ACS-BRK Brake Units ACS-BRK Brake Units Installation and Start-up Guide 3AFY 61514309 REV C EN Effective: 16.09.2002 2002 ABB Oy. Safety Warning! All electrical installation
More informationCONTROL AND PROTECTION PANEL FOR TRACTOR-PUMP CTR-087/0N THE TRACTOR/PUMP IS STOPPED WHEN THERE ARE ANOMALIES (VIA ELECTROMAGNET) CONCERNING:
CONTROL AND PROTECTION PANEL FOR TRACTOR-PUMP TYPE CTR-087/0N INSTRUCTION AND USER MANUAL NEVER USE THE DEVICE WHEN THE TRACTOR IS IN MOVEMENT THE TRACTOR/PUMP IS STOPPED WHEN THERE ARE ANOMALIES (VIA
More informationOperating instructions
SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature Differential Controller inputs, 1 output These operating instructions are part of the product. Read these
More informationMINI-MASTERZONE ZONING SYSTEM. MMP2 For Plug-In Damper Motors. Installation and Operating Instructions. 2 Zones. Controlling Your Comfort Room by Room
MINI-MASTEZONE ZONING SYSTEM MMP2 For Plug-In Damper Motors 2 Zones Installation and Operating Instructions ontrolling Your omfort oom by oom MINI-MASTEZONE ZONING SYSTEM MMP2 Features System Mode Indicator
More informationBelt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS
Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS 2 CE-Sign and Conformity The device meets the requirements of the valid European and national regulations. Conformity has been
More informationProduct Overview. Product Identification. Amps One CT Two CTs Three CTs
AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationFLUDEX - thermal switching equipment. Operating instructions BA en 04/2012. FLENDER couplings
FLUDEX - thermal switching equipment Operating instructions FLENDER couplings FLUDEX - thermal switching equipment Application Operation Fitting 1 2 3 Component description 4 Operating instructions Translation
More informationHEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N
HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N OPERATING & MAINTENANCE INSTRUCTIONS 1206 SPECIFICATIONS Supply Voltage 230 Max Charge (Amps) 60 (cont) Max Boost (Amps) 400 Boost/Charge (Volts)
More informationSUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS
SUBMERSIBLE PUMP Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS 0107 1 HIPPO 2 240 Volt and 110 Volt models Thank you for purchasing this Clarke Hippo 2 Pump. Before attempting to operate this
More informationRS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to
RS-3 PRO RS-1007 PRO CAT IV Analog Clamp meter Series Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com RS-3 PRO RS-1007 PRO CAT IV Analog Clampmeter Series English
More informationDocumentation. RM-BV4 Micro DP. Filter control
Documentation RM-BV4 Micro DP Filter control Contents 1 Safety instructions... 3 2 Device description... 3 3 Installation... 4 4 Installation... 5 4.1 Connection of the differential pressure measuring
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More informationUV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10
our name is our principle UV- TECHNOLOGY Technical Documentation ELC N6 / ELC N8 / ELC N10 GB eta plus electronic gmbh Lauterstraße 29, D-72622 Nürtingen, Telefon +49 (0) 70 22-60 02-80, Fax +49 (0) 70
More informationUser Manual Rittal PMC UPS 6kVA
User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...
More informationWMZ RESOL WMZ * * Mounting Connection Operation. Manual
RESOL WMZ Mounting Connection Operation *48003121* 48003121 WMZ Thank you for buying this RESOL product. Read this manual carefully to get the best perfomance from this unit en Manual www.resol.com Safety
More informationSMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL
SMC BATTERY CHARGER SMC 1 INDEX 1 INDEX... 1 2 INTRODUCTION... 2 2.1 INTRODUCTION AND REFERENCES... 2 2.2 GLOSSARY... 2 2.3 DATA LABEL... 2 2.4 HOW TO USE THE USER'S MANUAL... 2 2.5 RESPONSIBILITY DISCLAIMER...
More informationOperating Instructions
Operating Instructions Repair Light > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4 6 Transport, Storage and Disposal...6
More informationOperating Instructions
16 1 Independent & Unauthorized Changes and Spare Parts Alterations and changes to actuators are only possible, i.e. permitted under express permission from the company airpower Europe GmbH. These conditions
More informationChapter. Installation and. In this Chapter...
Chapter Installation and 2 Wiring In this Chapter... Ambient Conditions...2 2 Installation Considerations...2 2 Mounting Instructions...2 3 Controller and Panel Cutout Dimensions...2 4 Safety Information...2
More informationOperating Instruction for Downlights
Operating Instruction for Downlights Type: ES_T4_1027_SILVER/ ES_T5_1027_WHITE/ ES_T6_1017_SILVER/ ES_T7_1017_WHITE/ ES_T8_1047_SILVER/ ES_T9_2019_WHITE/ ES_T10_1044_SILVER Index 1. General safety information...
More informationSINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS
SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions
More informationREX/REX F/REX K/REX K F REX DUAL/REX DUAL F
TECHNICAL MANUAL REX/REX F/REX K/REX K F REX DUAL/REX DUAL F PRESSURISED STEEL BOILERS INDEX 1 GENERAL WARNINGS... 4 2 TECHNICAL SPECIFICATIONS... 5 2.1 REX/REX K/REX F/REX K F 7-130 BOILER... 5 2.2 REX/REX
More informationLM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to
LM-100 LM-120 Light Meters Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com LM-100 / LM-120 Light Meters English Users Manual LM100_Rev002 2008 Amprobe Test Tools.
More informationINFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT
INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT This Information Sheet provides guidance on how to carry out User Checks, Formal Visual Inspections and combined Inspection and Tests on portable
More information