[-]GTA. Parts List. CATALOG TAB - Downflow/Horizontal Gas Furnaces. Series A Sizes Downflow/Horizontal Furnace

Size: px
Start display at page:

Download "[-]GTA. Parts List. CATALOG TAB - Downflow/Horizontal Gas Furnaces. Series A Sizes Downflow/Horizontal Furnace"

Transcription

1 [-]GTA Parts List Downflow/Horizontal Furnace Series A Sizes Published August 2002 Form Number CATALOG TAB - Downflow/Horizontal Gas Furnaces

2 TABLE OF CONTENTS Notes Model Number Explanation Page 2 Page 3 Serial Number Explanation Page 3 Exploded View Page 4 Parts Page 5 Burner Page 6 Gas Controls Page 7 Ordering Instructions: ORDERING, STOCKING AND NOTE EXPLANATIONS When ordering a replacement part, be sure to read all notes and symbol notations on the parts list. In some cases, it is necessary to determine the unit style number and/or serial number in addition to the model number before selecting a replacement part. When ordering painted cabinet parts, the order must specify unit model number, serial number, and paint color. Also, your order can be processed more rapidly if you show the part number and description. Once the product is out of current production, price and availability will vary. Replacement Parts Stocking Information: As a general rule, most parts are in stock or have a short order period as long as the product is in current production. Once the product is out of current production price and availability will vary. Note Explanation: = This part is not shown in exploded view. [no picture] dna = Does not apply Page 2 of 8

3 [-] G T A E M A E S (1) (2) (3) (4) (5) (6) (7) (8) (9) (1) TRADEBRAND IDENTIFICATION (6) BLOWER DESIGNATION M = 11 x 7 (2) MODEL R = 11 x 10 G = GAS FURNACE Y = 12 x 7 (3) TYPE Z = 12 x 11 T = Downflow/Horizontal Condensing (4) DESIGN SERIES (7) VARIATIONS A = Standard (5) HEATING INPUT DESIGNATION B = Wide Cabinet Electric Ignition NOX MODEL NUMBER EXPLANATION Iut BTU/HR 04E 04N = 45,000 (8) HEATING & COOLING DESIGNATION 06E 06N = 60,000 E = CFM 07E 07N = 75,000 G = CFM 09E 09N = 90,000 J = CFM 10E 10N = 105,000 12E 12N = 120,000 (9) FUEL DESIGNATION SERIAL NUMBER EXPLANATION B = Canadian Furnace - Natural Gas S = U.S. Furnace - Natural Gas D G 5 D F (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (1) TYPE OF GAS CONTROL USED ON UNIT (4) HEATING ELEMENT DG = W/R 36E w/utec w/remote Sensor 7 = Stainless Steel DH = W/R 36E w/hw S9201 E-2001 w/remote Sensor DC = HW 8205H w/hw S9201 E-2001 w/remote Sensor (5) SPECIAL AREA REQUIREMENT DF = HW 8205H w/utec w/remote Sensor 0 = No Area Requirement EH = HW 8205H w/jci G961DAJ-2401 w/remote Sensor & PSE Spark Ignitor EJ = HW 8205H w/utec w/remote Sensor & PSE Spark Ignitor (6) MOTOR HORSEPOWER EK = WR 36E w/jci 6961 DAJ-2401 w/remote Sensor & PSE Spk Igntr 2 = 1/2 HP Motor EL = WR 36E w/utec w/remote Sensor & PSE Spark Ignitor 7 = 3/4 HP Motor (2) LIMIT CONTROL (7) PLANT 1 = WATSCO LIMIT CONTROL. F = Fort Smith, AR 5 = T.O.D. LIMIT CONTROL. (8) WEEK (3) BLOWER D = Direct Drive (9) YEAR (10) PRODUCTION NUMBER: Starts with and runs through Page 3 of 8

4 EXPLODED VIEW [-]GTA Page 4 of 8

5 NO. MODEL [-]GTA [-]GTA [-]GTA [-]GTA [-]GTA [-]GTA [-]GTA HEATING CAPACITY BLOWER DESIGNATION M M M Y Z Z R VARIATION A A A B A A A HEAT/COOL DESIGNATION E E E G J J J PANELS & SHEET METAL PARTS 1 JACKET AS AS AS AS AS AS AS TOP PLATE AE AE AE AE AE AE AE BLOWER/FILTER DOOR AS AS AS AS AS AS AS BURNER DOOR AS AS AS AS AS AS AS PLUG BUTTON MOUNTING CONTROL PLATE AE AE AE AE AE AE AE JUNCTION BOX AE AE AE AE AE AE AE INLET AIR CHASE ASSEMBLY AS AS AS AS AS AS AS PIPE ASSEMBLY ROLLOUT SWITCH BRKT AE AE AE AE AE AE AE PVC VANE PVC WIND VANE (2 1/2") WATER TRAP MOUNT BRKT AE AE AE AE AE AE AE CONNECTOR/TRANSITION JUNCTION BOX COVER AE AE AE AE AE AE AE DOOR ANGLE AS AS AS AS AS AS AS ELECTRIC GROUP 12 PRESSURE SWITCH DOOR SWITCH - Push Button LIMIT CONTROL LIMIT CONTROL (exposed) LIMIT CONTROL w/heater LIMIT CONTROL TRANSFORMER w/fuse CAPACITOR INDUCER MOTOR BLOWER GROUP 21 BLOWER ASSEMBLY AS AS AS AS AS AS AS HOUSING AS AS AS AS AS AS AS MOTOR CAPACITOR MOTOR MOUNT LEG (4) AE AE AE AE AE AE AE WHEEL HEAT EXCHANGER GROUP 27 HEAT EXCHANGER AS AS AS AS AS AS AS HEAT EXCHANGER BRKT AE AE AE AE AE AE AE HEAT EXCHANGER BRKT AE AE AE AE AE AE AE FILTER GROUP 30 FILTER - PLASTIC FILTER RACK AE AE AE AE AE AE AE Page 5 of 8

6 NO. MODEL [-]GTA [-]GTA [-]GTA [-]GTA [-]GTA [-]GTA [-]GTA HEATING CAPACITY BLOWER DESIGNATION M M M Y Z Z R VARIATION A A A B A A A HEAT/COOL DESIGNATION E E E G J J J BURNER / MANIFOLD GROUP [BEFORE 5/1/99] 33 BURNERS (3) (4) (5) (5) (6) (7) (8) 34 BURNER SUPPORT AE AE AE AE AE AE AE BURNER SUPPORT BRKT AE AE AE AE AE AE AE MANIFOLD w/o ORIFICE AS AS AS AS AS AS AS BURNER ORIFICE (Natural) listed below: U.S. MODELS ' & CANADIAN MODELS ' ELEVATION CANADIAN MODELS LP CONVERSION KITS listed below: U.S. MODELS ' Only FP-02 FP-02 FP-02 FP-02 FP-02 FP-02 FP-02 U.S. MODELS 8000' & Above Only FP-03 FP-03 FP-03 FP-03 FP-03 FP-03 FP-03 CANADIAN MODELS ' Only FP-05 FP-05 FP-05 FP-05 FP-05 FP-05 FP-05 BURNER / MANIFOLD GROUP [AFTER 5/1/99] 32 BURNER ASSEMBLY AS AS AS AS AS AS AS NOX BURNER INSERTS AE AE AE AE AE AE AE NOX RETAINING BRKT AE AE AE AE AE AE AE BURNERS AS AS AS AS AS AS AS BURNER SUPPORT AE AE AE AE AE AE AE BURNER SUPPORT BRKT AE AE AE AE AE AE AE DIRECT SPARK IGNITER BRKT AE AE AE AE AE AE AE MANIFOLD w/o ORIFICE AS AS AS AS AS AS AS BURNER ORIFICE (Natural) listed below: U.S. MODELS ' & CANADIAN MODELS ' ELEVATION CANADIAN MODELS LP CONVERSION KITS listed below: U.S. MODELS ' Only FP-02 FP-02 FP-02 FP-02 FP-02 FP-02 FP-02 U.S. MODELS 8000' & Above Only FP-03 FP-03 FP-03 FP-03 FP-03 FP-03 FP-03 CANADIAN MODELS ' Only FP-05 FP-05 FP-05 FP-05 FP-05 FP-05 FP-05 Page 6 of 8

7 GAS CONTROLS The Gas Controls listed below are specific to the [-]GTA Furnace NO DESCRIPTION DC DF DG DH 37 GAS VALVE INTEGRATED FURNACE CONTROL FLAME SENSOR dna dna NO DESCRIPTION EH EJ EK EL 37 GAS VALVE INTEGRATED FURNACE CONTROL IGNITOR IGNITOR - DIRECT SPARK IGNITOR BRACKET AE AE AE AE BRACKET - DIRECT SPARK AE AE AE AE IGNITOR SHIELD AE AE AE AE WIRE HARNESS (prior 8/01/98) AS AS AS AS WIRE HARNESS (after 8/01/98) AS AS AS AS WIRE HARNESS (prior 8/30/97) WIRE HARNESS (prior 4/27/02) WIRE HARNESS (after 4/27/02) (Twist-Lock) of 8

8 Printed in U.S.A. Air Conditioning Division P.O. Box Fort Smith, AR August R-01

[-]GPJ. CATALOG TAB - Gas Furnaces

[-]GPJ. CATALOG TAB - Gas Furnaces [-]GPJ PARTS LIST Upflow/Horizontal Gas Furnace SIZES: 05-15 SERIES: J Publication Date: January, 2003 Form No: 92-21650-48-02 CATALOG TAB - Gas Furnaces TABLE OF CONTENTS Notes Model Number Explanation

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. R801T-MSA,MXA Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/.pdf for the current revision. 80% Gas Furnaces Table of Contents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. Parts List 0-July-20 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. 9% Gas Furnaces Table of Contents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. R801S-MSA,MXA Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/.pdf for the current revision. 80% Gas Furnaces Table of Contents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. R801S-MSA,MXA Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/.pdf for the current revision. 80% Gas Furnaces Table of Contents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. 90% Gas Furnaces Table of Contents odel xplanation...................................................................................................................

More information

[-]CHL. Parts List Multiflex Cased or Uncased. (R-410A) Indoor Coils Series L Sizes CATALOG TAB - Indoor Coils

[-]CHL. Parts List Multiflex Cased or Uncased. (R-410A) Indoor Coils Series L Sizes CATALOG TAB - Indoor Coils [-]CHL Parts List Multiflex Cased or Uncased (R-410A) Indoor Coils Series L Sizes 24-61 Published September 2002 Form Number 92-24326-23-00 CATALOG TAB - Indoor Coils TABLE OF CONTENTS Notes Model Number

More information

ROBD. Oil Furnaces. Parts List 14-April-2011

ROBD. Oil Furnaces. Parts List 14-April-2011 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Oil Furnaces Table of Contents Model Explanation...................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List 16-anuary-2017 This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-.pdf for the current revision. 90% Gas Furnaces Table of Contents odel xplanation...................................................................................................................

More information

ROBF. Oil Furnaces. Parts List 14-April-2011

ROBF. Oil Furnaces. Parts List 14-April-2011 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. Oil Furnaces Table of Contents Model Explanation...................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. 80% Gas Furnaces - 2 Stage Table of Contents odel Explanation...................................................................................................................

More information

[-][-]AH DESIGN C. Parts List Electric Furnace/ Air Handler Sizes 14-24

[-][-]AH DESIGN C. Parts List Electric Furnace/ Air Handler Sizes 14-24 [-][-]AH DESIGN C Parts List Electric Furnace/ Air Handler Sizes 14-24 First Production Date June 2001 Published August 2001 PS Form Number 92-21619-79-00 CATALOG TAB - Air Handler Notes Model Number Explanation

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-.pdf for the current revision. Package Gas-Electric - Commercial Table of Contents Model

More information

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL

More information

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace RGTK- Series 92% A.F.U.E. or Above 60-120 kbtu with Dual Comfort Control A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Rheem Classic Plus Series Downflow Gas Furnace

Rheem Classic Plus Series Downflow Gas Furnace Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

Table of Contents GF801U Series

Table of Contents GF801U Series FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-485 REV. 5 Supersedes Form No. G11-485 Rev. 4 GAS FURNACES RGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace RGPT- Series 80% A.F.U.E. Input Rates 50-125 kbtu ENER UIDE Annual Fuel Utilization Efficiency

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. 80% Gas Furnaces - 2 Stage Table of Contents odel xplanation...................................................................................................................

More information

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces

More information

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. ) FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42800-.pdf for the current revision. 80% Gas Furnaces - 2 Stage Table of Contents odel Explanation...................................................................................................................

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

REPAIR PARTS. Tubular Gas Furnaces GDT, GMT, GMTH

REPAIR PARTS. Tubular Gas Furnaces GDT, GMT, GMTH REPAIR PARTS Tubular Gas Furnaces GDT, GMT, GMTH GDT045-3A GDT070-3A GDT090-4A GDT5-5A GMT045-3A GMT070-3A GMT070-4A GMT090-3A GMT090-4A GMT090-5A GMT5-5A GMT140-5A GMTH045-3A GMTH070-4A GMTH090-5A Goodman

More information

Rheem Classic Series Downflow Gas Furnace

Rheem Classic Series Downflow Gas Furnace Gas Furnaces Rheem Classic Series Downflow Gas Furnace R801S (Downflow) Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department

More information

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE FORM NO. G22-448 REV. 10 Supersedes Form No. G22-448 Rev. 9 GAS FURNACES UGPH- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace THIS MODEL Air Gas Furnaces Rheem Classic Series Upflow/Horizontal Gas Furnace R801S- (Upflow/Horizontal) Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE

More information

G95V Series Gas-Fired 95% 2-Stage High Efficiency (Condensing) Multi-Positional Furnace w/ ECM Circulator

G95V Series Gas-Fired 95% 2-Stage High Efficiency (Condensing) Multi-Positional Furnace w/ ECM Circulator 5/23/07 G95V Service Parts 1 Key No. Description Cabinet Group Top Panel Left Side Panel Assembly Right Side Panel Assembly Rear Panel Blower Division Panel Assembly,,, Base Panel,, Upper Front Door Panel,

More information

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G22-485 REV. 4 Supersedes Form No. G22-485 Rev. 3 GAS FURNACES UGPN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization

More information

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G11-486 REV. 3 Supersedes Form No. G11-486 Rev. 2 GAS FURNACES RGPP- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel

More information

Rheem Value Series Downflow Gas Furnace

Rheem Value Series Downflow Gas Furnace THIS MODEL 80.0% 78% 82% 88% 97% Air Gas Furnaces Rheem Value Series Downflow Gas Furnace RGLS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE MID A.F.U.E.

More information

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-547-1000 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KH 55 thru 285 44 3 4 43 2 47 46

More information

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace Gas Furnaces Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace U802V Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev V

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev V Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 615-889-8900 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Armor Condensing Water Heater AW 151 thru 801 41 4 10 38

More information

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity

More information

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace R802P- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev W

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev W Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Armor Condensing Water Heater AW 151 thru 801 41 4 10 38

More information

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B

Replacement Parts List. Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & _ _Rev B Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KHB 055 thru 285 Series 100 & 101

More information

UPFLOW/ HORIZONTAL GAS FURNACE

UPFLOW/ HORIZONTAL GAS FURNACE FORM NO. GFJ-542 UPFLOW/ HORIZONTAL GAS FURNACE Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark Ignition for reliability and longevity

More information

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace R802V- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization

More information

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces THIS MODEL 78% 82% 88% 92.0% 97% Air Gas Furnaces Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces RGPQ- Series 80% A.F.U.E. Models with Input Rates from 45-105 kbtu (U.S. & Canadian Models)

More information

GY8S UPFLOW/HORIZONTAL (80%) NATURAL GAS FURNACES (STYLE C, see back ) INCLUDING LO-NOX (LY8S Models)

GY8S UPFLOW/HORIZONTAL (80%) NATURAL GAS FURNACES (STYLE C, see back ) INCLUDING LO-NOX (LY8S Models) www.source1parts.com HVAC SERVICE PARTS GY8S UPFLOW/HORIZONTAL (80%) NATURAL GAS FURNACES (STYLE C, see back ) INCLUDING LO-NOX (LY8S Models) Supersedes: 035-20836-001 Rev. C (1106) 035-20836-001 Rev.

More information

Figure 1-1(d) Tft Installation Kit

Figure 1-1(d) Tft Installation Kit TRINITY TFT60-399 PARTS LIST For a list of parts that corresponds to the item numbers in the callouts, refer to Table 1-1. Note that some item numbers may appear more than once in the parts list depending

More information

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES FORM NO. G66-495 Supersedes Form No. P66-765 Rev. 3 80PS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80% A.F.U.E. UPF/ HORIZONTAL GAS FURNACES The WeatherKing line of upflow/horizontal

More information

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-100 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev E

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev E Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-547-1000 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KH 55 thru 285 44 3 4 43 2 47 46

More information

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1 TZ80MSS (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42806-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................

More information

REPLACEMENT PARTS LIST. M1 Series

REPLACEMENT PARTS LIST. M1 Series REPLACEMENT PARTS LIST M Series Model MG(*) Item Description MGH MG(B,C,D) 056 070 077 090 056 070 077 090 Louvered Door (White) 9007 9007 9007 9007 9007 9007 9007 9007 Coil Door (White) 9009 9009 9009

More information

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev. 1 UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ 7 Segment LED all units Direct Spark

More information

Save This Manual For Future Reference

Save This Manual For Future Reference Save This Manual For Future Reference Models H8UH5050BC H8UH5075BC H8UH500F4C H8UH55J0C H8UH5J0C MUF050WC MUF075WC MUF00WC MUF5W5C MUFW5C HLHTRC HL8HTRC HL5HTRC HLH4TRC HL4H5TRC International Comfort Products,

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 5 Supersedes Form No. G66-478 Rev. 4 80PJ SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing

More information

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) FORM NO. G66-542 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features

More information

Replacement Parts List

Replacement Parts List 100275093_2000534000_Rev H Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Noble Boiler & Combi NKB 080-150

More information

80% A.F.U.E. DOWNFLOW GAS FURNACES

80% A.F.U.E. DOWNFLOW GAS FURNACES FORM NO. G66-496 REV. 5 Supersedes Form No. G66-496 Rev. 4 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The

More information

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) FORM NO. G66-544 REV. 4 Supersedes Form No. G66-536 Rev. 3 W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. ) UPFLOW/ HORIZONTAL GAS FURNACES Features 80% residential

More information

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES FORM NO. G66-478 REV. 1 Supersedes Form No. G66-478 Rev. 0 80 PLUS A.F.U.E. UPF/HORIZONTAL GAS FURNACES Features The WeatherKing line of upflow/horizontal gas furnaces are designed for utility rooms, closets,

More information

13PJA. Heat Pumps. Parts List 20-July-2015

13PJA. Heat Pumps. Parts List 20-July-2015 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42803-.pdf for the current revision. Heat Pumps Table of Contents Model Explanation...................................................................................................................

More information

KG7T (E and N Series)

KG7T (E and N Series) TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas

More information

B No. Notes COOLING CAPACITY 072 HEATING CAPACITY

B No. Notes COOLING CAPACITY 072 HEATING CAPACITY MOEL OOLING APAITY 10 13 HEAT EXHANGER, URNER/MANIFOL 45 Stk Main Limit - (ondenser ulkhead) E - Electric 47-23610-19 47-23610-19 45 Stk Main Limit - (ondenser ulkhead) X - NOX 47-23610-19 47-23610-19

More information

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE

15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.

More information

FG7T (E and N Series)

FG7T (E and N Series) TECHNICAL SPECIFICATIONS FG7T (E and N Series), Smartlite Two Stage, Fixed Speed ECM, High Efficiency Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency

More information

KG7S (A and K Series)

KG7S (A and K Series) TECHNICAL SPECIFICATIONS KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 80+ AFUE Input 45,000-126,000 Btuh The high efficiency gas furnace may be installed

More information

MPSH03CG-H05CG(D)

MPSH03CG-H05CG(D) H03-H05() Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807-H03-H05()

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED GAS/ELECTRIC Models: WG-A WG-B WG-C W0G-A W0G-B W0G-C W6G-A W6G-B W6G-C Contents Description Page Cabinet Components Exploded View... Usage List... Usage List... Functional

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS KG7S (C and L Series) High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92. AFUE Input 38,000-20,000 Btuh

More information

Contents. Burner Components. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Contents. Burner Components. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED GAS/ELECTRIC MODELS: W2G-A W2G-B W2G-C W8G-A W8G-B W8G-C W60G-A W60G-B W60G-C General Notes Contents Revised and/or additional pages may be issued from time to time.

More information

Contents. Burner Components. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Contents. Burner Components. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506 REPLACEMENT PARTS MANUAL WALL MOUNTED GAS/ELECTRIC MODELS: WG2-A WG2-B WG2-C WG82-A WG82-B WG8-C WG602-A WG602-B WG60-C General Notes Contents Revised and/or additional pages may be issued from time to

More information

H-Series Low NOx INDUCED DRAFT HEATER REPLACEMENT PARTS. Parts Diagram. H e a t i n g

H-Series Low NOx INDUCED DRAFT HEATER REPLACEMENT PARTS. Parts Diagram. H e a t i n g Parts Diagram H-Series Low NOx INDUCED DRAFT 1 2 3 39 5 38 4 40 6 41 22 8 3 31 30 23 34 33 32 29 24 35 2 28 36 159 H-Series Low NOx INDUCED DRAFT Parts Listing 1 HAXJKT1150 Jacket Top Assembly 150 5 HAXWHA000

More information

Replacement Parts List. Armor Condensing Water Heater. AW 150 thru 800

Replacement Parts List. Armor Condensing Water Heater. AW 150 thru 800 AW-RP_100160820_2000000353_Rev Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 6-889-8900 Fax: 6-882-2918 parts_team@lochinvar.com www.lochinvar.com Armor Condensing Water Heater

More information

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS GUH 95 Series Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency upflow gas

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL MOUNTED GAS/ELECTRIC WG-A WG-B WG-C Models: W8G-A W8G-B W8G-C W60G-A W60G-B W60G-C Contents Description Page Cabinet Components Exploded View... Usage List... Usage List...

More information

FG7S (C and L Series)

FG7S (C and L Series) TECHNICAL SPECIFICATIONS FG7S (C and L Series) High Efficiency/Direct Vent or Non Direct Vent Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 92.1 AFUE Input 38,000-120,000

More information

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN A951E PRODUCT SPECIFICATIONS SINGLE STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A951E-100 (10/2018) CONTROLS Single stage gas valve Durable silicon nitride ignitor Self diagnostics saves

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See  for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-805-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-800-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................

More information

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger Single Stage - High Efficiency (Constant Torque) Motor 95% Gas Furnaces Features and Benefits CONFIGURATIONS Upflow / Horizontal Downflow 95G1-E Form No. D95G1-E-100 (10/2011) HEAT EXCHANGER DESIGN Aluminized

More information

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE FORM NO. A962E-100 (04/2018) CONTROLS Two stage gas valve Integrated ignition and fan control System Sentry control retains

More information

This parts list is current as of the above revision date. See for the current revision.

This parts list is current as of the above revision date. See   for the current revision. Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-801-.pdf for the current revision. Condensing Units Table of Contents Model Explanation...................................................................................................................

More information

Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency

Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency Gas Furnaces PRODUCT SPECIFICATIONS INSTALLATION OPTIONS A vailable in Upflow/Horizontal and Counterflow models 80% AFUE 44,000 to 32,000 Btuh Input.5 to 5 Tons Add-On Cooling HEAT EXCHANGER A luminized

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE COMFORT 95 DIRECT OR NON---DIRECT VENT 4 --- WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct

More information

KG7T (C and L Series)

KG7T (C and L Series) TECHNICAL SPECIFICATIONS KG7T (C and L Series) Two Stage, Fixed Speed ECM, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The high efficiency

More information

XR8 SERIES GAS & ELECTRIC ROTATING RACK CONVECTION OVENS REPLACEMENT PARTS LIST

XR8 SERIES GAS & ELECTRIC ROTATING RACK CONVECTION OVENS REPLACEMENT PARTS LIST XR SERIES GAS & ELECTRIC ROTATING RACK CONVECTION OVENS REPLACEMENT PARTS LIST EFFECTIVE JUNE, 202 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event

More information

Rheem Value Series Upflow/Horizontal Gas Furnace

Rheem Value Series Upflow/Horizontal Gas Furnace THIS MODEL Gas Furnaces Rheem Value Series Upflow/Horizontal Gas Furnace RGPS- Series 80% A.F.U.E. Input Rates 50-150 kbtu ENER UIDE Annual Fuel Utilization Efficiency - AFUE 80.0% MID HIGH 78% 82% 88%

More information

Power Direct Vent PDV T Model

Power Direct Vent PDV T Model REPLACEMENT PARTS LIST Power Direct Vent PDV T Model Includes Hydrojet Sediment Reduction System Effective: January, 2012 ECO 7731 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING REPLACEMENT

More information

TSTAT0101SC Recommended (sold separately)

TSTAT0101SC Recommended (sold separately) Up to 96% AFUE, Communicating, Two Stage Gas Furnace EASIER TO SELL Up to 96% AFUE, all models, all positions California NOx approved All Models have earned the ENERGY STAR Two stage heating operation

More information

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input TECHNICAL SPECIFICATIONS VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38,000-120,000 Btuh Input The high efficiency upflow

More information

15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS

15B SERIES II. Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.

More information

Comfort Pack Archived Part Lists PARTS LISTS

Comfort Pack Archived Part Lists PARTS LISTS Comfort Pack Archived Part Lists PARTS LISTS CPGXX38-X Description 14208336 Natural Gas Orifice - 38 14208343 LP Gas Conversion Kit - 38 14208329 Heat Exchanger Assembly - 38 14208332 Full Burner Body

More information

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized

More information

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE Heating Input: 40,000 100,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...4 Airflow Data...5 Wiring Diagram...7 Accessories...8

More information

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER 96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR FORM NO. 96G1E-100 (04/2018) VENTING Designed certified for direct (2-pipe) and non direct (1-pipe) applications Easily vented with PVC pipe

More information

XR8 SERIES. Effective june 12, 2015

XR8 SERIES. Effective june 12, 2015 XR8 SERIES gas & ELECTRIC ROTATING RACK convection ovens REPLACEMENT PARTS LIST Effective june 2, 20 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event

More information

Section 6. Parts Data CABINET GROUP

Section 6. Parts Data CABINET GROUP 31 Section 6 Parts Data CABINET GROUP * 9960-256-027 Door Assy., Loading Complete-Alm... 2 * 9960-256-026 Door Assy., Loading Complete-Wht... 2 * 9960-256-030 Door Assy., Loading Complete-SS... 2 1 9960-255-008

More information