MOUNTED BEARING UNITS

Size: px
Start display at page:

Download "MOUNTED BEARING UNITS"

Transcription

1 MOUNTED ERING UNIT NIPPON PILLOW LOCK CO., LTD. CT.NO.

2 fyhbea rin NIPPON PILLOW LOCK CO., LTD. g HED OFFICE om s.c Hirao Mihara-ku akai Osaka - Japan TEL: +--- FX: info@fyhbearings.com INTERNTIONL DIVIION exports@fyh.co.jp FYH ERING UNIT U INC. FYH Drive Huntley, Illinois 4, U TEL: FX: sales@fyhusa.com DOMETIC RNCHE IN JPN Tokyo Nagoya apporo Fukuoka Hiroshima Kase uilding - F --4 Katsushima hinagawa Tokyo 4- Japan TEL: +--- FX: tokyo@fyh.co.jp -- Niban tsuta-ku Nagoya ichi 4- Japan TEL: +--- FX: nagoya@fyh.co.jp sapporo@fyh.co.jp kyusyu@fyh.co.jp fukuyama@fyh.co.jp

3 Mounted earing Units (contents) Technical ection Technical ection Pillow lock Units 4-olt Flange Units Oval Flange Units 4-olt Flange Cartridge Units LL ERING UNIT tamped teel Flange Units Take-Up Units Cartridge Units Hanger Units all earing Inserts PHERICL ROLLER ERING UNIT Parts and ccessories Technical ection pherical Roller earing Units Parts and ccessories Technical ection ppendix Table ppendix Table

4 Contents Technical ection tructure and Features LL ERING UNIT trength of Housings. tructure.... Features... election Guide. election Guide.... High / Low Temperature eries.... Corrosion Resistant eries....4 ir Handing eries.... Dust Resistant Units... Models. Model List.... Models and Features... 4 Rating Life of earings 4. asic Rating Life and asic Load Rating.. 4. Calculation of Rating Life Grease Life... earing Load. Loads pplied to earings.... Distribution of earing Load.... Dynamic Equivalent Load....4 asic tatic Load Rating and tatic Equivalent Load.... Example of pplied Calculation... 4 llowable Rotating peed. llowable Rotating peed Rotational peed djustment Due to haft Fit... 4 Operating Temperature and earing pecifications. Operating Temperature Range trength of Cast Iron Housings trength of Ductile Cast Iron Housings trength of tamped teel Housings trength of tainless teel Housings trength of Die-cast Housings tatic Rupture trength of Plastic Housings.. Design of haft and ase. Design of haft.... Mounting ase Design.... Dowel Pins for ccurate Unit Mounting... Nomenclature... ccuracy and Internal Clearance. ccuracy of earings.... ccuracy of Housings.... Internal earing Clearance... Materials. earing Material.... Housing Material.... Materials of Parts and ccessories... Performance. earing Friction Torque.... earing Temperature Increase... 4 Handling 4. Installation Test Run Inspection Periodic Inspection upply of Grease Replacing earings.... Operating Temperature and Internal Clearance of earings... 4

5 Unit Dimensional Table Dimensional Tables for all earing Units... Pillow lock Units Pillow lock Units... Thick Pillow lock Units... Tapped-ase Pillow lock Units... High-ase Pillow lock Units... 4 Narrow Inner Ring earing Pillow lock Units... Light Pillow lock Units... Compact Pillow lock Units... Corrosion Resistant eries Pillow lock Units... 4 tamped teel Pillow lock Units... 4-olt Flange Units 4-olt Flange Units... quare Piloted 4-olt Flange Units... Narrow Inner Ring earing 4-olt Flange Units... 4 Corrosion Resistant eries 4-olt Flange Units... Oval Flange Units -olt Flange Units... 4 djustable -olt Flange Units olt Flange Units... Narrow Inner Ring earing -olt Flange Units... Light -olt Flange Units... Light -olt Flange Units... Compact -olt Flange Units... 4 Corrosion Resistant eries -olt Flange Units... Corrosion Resistant eries -olt Flange Units olt Flange Cartridge Units 4-olt Flange Cartridge Units... Narrow Inner Ring earing 4-olt Flange Cartridge Units... Corrosion Resistant eries 4-olt Flange Cartridge Units... 4 Take-Up Units Take-Up Units... 4 Narrow lot Take-Up Units... Corrosion Resistant eries Take-Up Units... ection teel Frame Take-Up Units... Channel teel Frame Take-Up Units... teel Plate Frame Take-Up Units... 4 Other Units Cartridge Units... Hanger Units... 4 all earing Inserts Cylindrical bore (with set screws)... tainless steel series Cylindrical bore (with set screws)... 4 Cylindrical bore (with eccentric locking collar)... Cylindrical bore (with concentric locking collar)... Cylindrical bore (with concentric locking collar) Cylindrical O. D Tapered bore (with adapter)... Cylindrical bore (with set screws) Cylindrical O. D.... Cylindrical bore (with eccentric locking collar) Cylindrical O. D Cylindrical bore... earing dapter... Parts and ccessories Parts and ccessories. Part No. of teel Plate Covers.... Part No. of Cast Iron Covers... tamped teel Flange Units tamped teel -olt Flange Cartridge Units... tamped teel -olt Flange Units...

6 Contents PHERICL ROLLER ERING UNIT pherical Roller earing Units (contents)... tructure and Features. tructure.... Features... Models. Model List.... Models and Features... Nomenclature... 4 Engineering Information... Installation Guide. Precautions Preparation Installation....4 Lubrication... Dimensional Tables for pherical Roller earing Units... ppendix Table ppendix Table (contents)... implified Chart of all earing Unit Combinations... Tightening Torques of Housings and Cast Iron Cover Mounting olts... Tightening Torques of Inner Rings and Eccentric Locking Collar et crews... 4 Tightening Torques of dapter Lock Nuts (reference)... Machining Dimensions of Holes of Housing Dowel Pins... Dimensional Tolerances of hafts... 4 Dimensional Tolerances of Housing ores... asic Tolerance Values... I Unit Conversion Charts... Inch-meter Conversion Chart... Hardness Conversion Chart... Viscosity Conversion Chart... Mechanical Properties of Metal Materials (reference)... 4 Hexagon ocket Head Cap crews (abstract from JI )... 4 Hexagon Head olts (abstract from JI )... Hexagon Head Nuts (abstract from JI )... all earing Units Interchange Guide... pherical Roller earing Units Interchange Guide... The contents of this catalogue are subject to change without prior notice. Every possible effort has been made to ensure that the data listed in this catalog is correct. However, we can not assume responsibility for any errors or omissions. ll rights reserved.

7 tructure and Features FYH all earing Units are manufactured to exacting standards comprising of grease sealed deep groove ball bearings and housings in various forms. elf-aligning units allow for easy installation and are supplied with grease fittings in order to facilitate quick and convenient re-lubrication.. tructure FYH all earing Units are constructed of high carbon chromium bearing steel and have precision honed raceways and riveted steel cages (Fig..). Grease fitting Grease hole linger Outer ring with spherical outside surface Double lip Floack seal all and cage ullet Point set screw Wide inner ring Extra olid base cast iron housing Fig.. tructure of ball bearing units (representative example). Features FYH all earing Units have many features and are available in various models. wide selection of mounted units is offered to fit virtually any application. upreme load capacity and accuracy FYH all earing Units feature an internal structure identical to single row deep groove ball bearings and can bear significant radial load, as well as a great deal of axial load in both directions. The hardened steel balls exhibit a high degree of roundness and the races are highly polished to accoodate a smooth ride at a wide range of speeds. This design allows the bearing unit to self-adjust for shaft deviation and reduce abnormal bearing load. Therefore, the original rated life of the bearing can be guaranteed. ince the spherical outside surface of the bearing is precision ground and the spherical bore of the housing is machined by a boring machine with great accuracy, optimal fitting of the bearing and the housing can be obtained, as well as superior aligning performance. The allowable aligning angle of standard ball bearing units is º, while units with covers is º. Rational self-aligning mechanism and optimal fit FYH all earing Units have the special ability to self-align inside the housing because of the spherical shape of the outer diameter of the bearing insert and the concave shape of the inner diameter of the housing into which it fits. ligning angle ligning angle Fig.. llowable aligning angle of ball bearing units

8 tructure and Features uperior sealing performance FYH all earing Units efficiently prevent grease from leaking out of the interior of the bearing, and perform extremely well at keeping contaminates, such as dust and water, from entering. This is achieved by installing the seal to the outer ring of the bearing and installing the slinger to the inner ring of the bearing. The Floack seal to be used in the standard FYH all earing units will contribute to the long life of the bearing. It consists of a double-lip seal which is stamped into place in the outer ring of the bearing to reduce the possibility of being pushed out from over-lubrication. The first seal makes contact with the inside of the slinger which provides the first line of defense against contamination. The next seal makes contact with the inner ring to provide another level of contamination resistance. n additional level of protection exists in the extra non-contact inward facing lip which allows grease to flow back towards the balls and raceways during operation thereby improving lubrication performance and extending bearing life. llowable rotating speed is the same as the previous seal design while providing more than four times better protection. 4 imple lubrication FYH all earing Units are tapped to accept a grease fitting which is also supplied with every mounted unit. earings are pre-lubricated at the factory and do not require additional grease upon installation. When operating in excessively moist, dusty, or hot environments, it is recoended that grease be supplied at regular intervals. If appropriately maintained, the rated life of the bearing can be extended. FYH Lithium earing Grease to be sealed in early bearing grease use are manufactured to accoodate a wide range of operating conditions. FYH Lithium earing Grease can be mixed with of former FYH earing grease as it will improve performance, corrosion resistance, loading capability, and promote longer bearing life. The grease fittings that are supplied with FYH mounted units include - for smaller units and PT for larger units. dditional styles are available upon request. FYH Lithium earing Grease is also available in automatic lubricators. Floack eal Fig.. ealing mechanism of ball bearing units

9 Highly rigid and rugged cast iron housings FYH all earing Unit housings are designed so that they are optimized for reduction of deformation due to centralization of stress and load. Only the best material is selected to be cast by a highly advanced technique or press working technique, depending on the housing. ince any abnormal load on the bearing is eliminated by the housing, the life of the bearing can be extended. Granular material baking finish coating (powder coating) helps resist corrosion and protect the surface of the housing for an extended period of time. FYH original solid base pillow block housings seat better and produce a more stable mounting configuration that significantly reduces vibration. The support ribs have been eliminated to make more room for mounting bolts and washers, yet these housings are more than % stronger than before while also reducing housing weight. The new housing downward destruction strength means that the inserts break before the housings. eries and models FYH all earing Units are available in various series and models. Reliability of machinery or equipment, used together with these units, can be improved by selecting and using units optimal for the application and operating conditions. $High / Low Temperature eries $Corrosion Resistant eries tainless Units Plastic Units Nickel plated Units $ir Handling eries & earing Units NU-LOC Units $Dust Resistant Units Triple lip seal inserts Felt seal inserts $Dirt Resistant Units Tight Triple lip seal inserts Units with Covers imple installation and handling FYH all earing Units interchange with many different models and can be bolted to machinery without any modification. The exact amount of clearance is allowed between the bore and the shaft to allow a perfect fit. Therefore, FYH all earing Units do not require any additional lubrication or seal installation. s a result, handling and downtime can be drastically reduced. Four different locking mechanisms are available: $Tougher casting eries Ductile iron housing $Compact and lightweight eries mall die cast Units Lightweight casting Units tamped Units () et crew () Eccentric Locking Collar () Tapered dapter (4) Concentric Collar Mounting the bearing to the shaft can be executed easily and securely by adopting any of these methods.

10 election Guide election Guide. election Guide. elect the housing style that best suits your application. P - PILLOW LOCK P - TPPED-E PH - HIGH-E LP - LIGHT IP - THICK PP - TMPED TEEL F - 4-OLT FLNGE F - QURE PILOTED FL - -OLT FLNGE LF - LIGHT PFL - TMPED TEEL F - DJUTLE F - -OLT FLNGE FC - 4-OLT FLNGE CRTRIDGE T - TKE-UP C - CRTRIDGE H - HNGER. elect the shaft size and duty that is needed for your application. U - FROM MM TO MM ORE & - FROM MM & TO 4 MM & -/ ORE UC - FROM MM & TO 4 MM ORE N - FROM MM & TO MM & ORE NC - FROM MM & TO MM & -/ ORE UK - FROM MM & TO MM ORE

11 . Do you need to customize the bearing for your application? elect TNDRD as the default. TEMP - DK - F TO 4 F (- C TO C), DK -4 F TO F (-4 C TO C), DK -4 F TO 44 F (- C TO C) WH DOWN - TINLE TEEL UNIT, PLTIC HOUING UNIT, IR HNDLING - IR HNDLING FIT UNIT, NON CONTCT EL DUT - L TRIPLE LIP EL, COVER DIRT - LT TIGHT TRIPLE LIP EL, COVER 4. elect the locking style type for your insert. UC - ETCREW LOCK N - ECCENTRIC COLLR LOCK NC - CONCENTRIC COLLR LOCK UK - DPTER LEEVE LOCK. YOUR UNIT election application is available for download in the mobile device.

12 election Guide TEMP. High / Low Temperature eries (suffix codes - High temperature: DK & DK, Low temperature: DK) For applications that require bearing units to be used at a higher or lower temperature range than our standard models FYH offers several options. For high temperature units that require lubrication please specify DK as a suffix to the standard part number. For high temperature units that do not require lubrication specify DK. The DK insert uses a fluoro-grease that allows for excellent heat resistance and operation with minimal maintenance. pecifications for the high temperature and low temperature units are shown in Table.. Category uffix code Table. pecifications of High / Low Temperature eries pecifications of High / Low Temperature eries Operating temperature range Grease eal rubber material earing internal clearance (ºC) (ºF) UC type UK type tandard - to 4 to FYH Lithium earing Grease (lithium complex) Nitrile CN C Cold resistant DK to to 4 HM (lithium) ilicone CN C Heat resistant DK 4 to 4 to U-RET EDM- (diurea) ilicone C4 C Heat resistant DK to 4 to 44 Demnum L- (f luorinated grease) ilicone C4 C pecifications of Extreme High Temperature eries Operating eal earing internal uffix Category temperature range Grease rubber clearance code (ºC) (ºF) material UC type UK type Heat resistant DP4Y to 4 to Demnum L- (fluorinated grease) - C4 - Extreme heat resistant Y to 4 to 4 olid graphite lubricant - pecial - Operating temperature ºC Over Incl. ubstantially clean ( months) not necessary year months months weeks week Table. Grease chedule of all earing Units Grease schedule of ball bearing units Grease Intervals Excessive dust ( months) year 4 months months weeks days days Excessive dust and moisture ( month) 4 months month weeks days days day earing used (Low temperature DK) ) tandard bearing High temperature DK Grease supplied HM FYH Lithium - earing Grease U-RET EDM- Note ) Greasing intervals in parentheses are applicable to low temperature grease (DK). Remark Greasing intervals shown in this table are applicable to a unit operated for to hours per day. If the time of operation is greater than this range, then a more frequent greasing interval must be specified. For example, if the unit is operated to hours per day, then the greasing interval must be twice as frequent.

13 .. Rotational speed adjustment due to shaft fit marginal degree of clearance is typically used to facilitate easy installation of a bearing to a shaft. The amount of clearance between the bearing and shaft must be factored in to determine the maximum allowable rotational speed, and as rotational speed is increased, the amount of clearance must be decreased. Table. shows the factor that must be used to correct the allowable rotational speed. The maximum rotational speed is determined by multiplying the speed found in Table. by the factors below. Table. Fitting factor of ball bearing units f c (recoended) Type of ball bearing units Heat resistant type (uffix code: DK) Cold resistant type (uffix code: DK) Fitting factor f c haft tolerance range class h, j j h h h h.... Operating temperature range The operating temperature of a ball bearing unit depends on the type of grease, the material of the seal, and the internal clearance of the bearing. FYH all earing Units are available in high temperature (DK, DK) and low temperature (DK) series, in addition to the standard models, to allow selection of the correct bearing for your operational temperature (see Table.). The correct unit must be chosen for the desired temperature range, and it is equally important to use the appropriate grease according to the specified schedule...4 Operating temperature and internal clearance of bearings When bearings are operated in a high ambient temperature environment, or when the operating temperature is high because of rotational speed, differential expansion rates occur within the bearing components. This causes higher friction, grease breakdown, and eventual seizure. If the temperature difference between the inner and outer ring is known, or can be approximated, then the following Formula (.) may be applied. Under these conditions, decrease in the internal clearance must be calculated, and the internal clearance of bearing needs to be selected properly... Correction of basic load rating due to temperature If a ball bearing unit is used at a relatively high temperature the physical composition of the bearing material is changed leading to decreased hardness. This decreased hardness leads to the basic dynamic load rating being reduced. Once the structure of the bearing material has been changed, it will remain this way for the life of the unit, even when it returns to room temperature. When using a ball bearing unit at ºC or more, the basic load rating must be corrected by multiplying the basic dynamic load rating shown in the dimensional table by the temperature factor shown in Table.4. Table.4 Temperature factor earing temperature, ºC Temperature factor... t = α De t (.) Whereas, t: Decrease in the internal clearance of bearings depending on the difference in the temperatures of the bearing inner ring and the bearing outer ring can be found by formula, α: Line expansion factor of bearing steel,. De: Raceway dia. of bearing outer ring, Diameter series, X De. D Diameter series De. D D: Nominal bearing outer dia., t: Difference in temperatures of bearing inner ring and outer ring, ºC If a ball bearing unit is used in a high temperature environment, an abnormal load will result due to thermal expansion of the shaft. This must be compensated for by allowing free movement of one side of the shaft. (ee Design of shaft and base ) CERMIC LL UNIT Y: Ceramic balls with stainless units Y: Ceramic balls with a solid self-lubricating lubricant Ceramic all Units features Reduced maintenance costs Green bearings Independent operation Low friction High stress resistance Non-conductive

14 election Guide. Corrosion Resistant eries The Corrosion Resistant eries is available in a wide array of sizes and styles, and units may be customized with a number of different specialized options to accoodate virtually any application. Federal compliance can be assured with FYH earing Units. WH DOWN TINLE INERT PLTED INERT RING LL CGE GREE EL LINGER NTI-ROTTION PIN tainless steel (U 44C equivalent) U 44C U4 H FOOD GRDE (FD /UD) NR U4 U4 ET CREW U4 VILLE IZE X - X, 4 - CLERNCE C RING LL CGE GREE EL LINGER NTI-ROTTION PIN UJ + (zinc plated + trivalent chromate treatment) UJ NYLON H FOOD GRDE (FD /UD) NR PCC + (zinc plated + trivalent chromate treatment) U4 ET CREW CM4 + (zinc plated + trivalent chromate treatment) VILLE IZE 4 - CLERNCE C VP VF VFL VP H, H Z Thermoplastic Housings tainless teel Housings Nickel Plated Housings Thermoplastic Polyester Lost Wax Casting (U4 or equivalent) Cast Iron + Nickel Plating

15 IR HNDLING.4 ir Handing eries Units for HVC and air handling (suffix code:, ) all bearing units for blowers must meet the demands of high speed rotation, low vibration, low noise, and decreased temperature output. To meet these performance needs FYH produces the and series with tighter bore tolerances. uses non-contact seals as well as an improved machining accuracy to cut down on heat, noise, and vibration. Table. pecifications of air handling units IR HNDLING TNDRD ir Handling Fit % Noise Check P The anti-rotation pin IR HNDLING NON CONTCT EL ir Handling Fit % Noise Check P C P K The anti-rotation pin Internal bearing clearance is defined as the allowable space between the rolling elements and the raceways. C is smaller clearance than the standard, and it reduces the noise and vibration in high speed applications. P is the suffix code that designates smaller bore tolerance which allows for a tighter fit with the shaft. This, in turn, reduces vibration and noise and dramatically increases bearing life. Non contact lip seal is available for the lighter torque.

16 election Guide.4. Features of the air handring units The air handling unit is manufactured with original fitting called the air handling fit which exists in the middle with fitting H which can be assembled more easily than a standard fit J. In addition, J fit the standard is fit that there is not the need for the anti-rotation pin, but can be very secure in high speed applications by adding the anti-rotation pin. and bearings are sound tested in order to make sure the noise level is low enough to be suitable for high speed applications such as blowers..4. Feature of air handring specification for blowers () Dimensional tolerances of shafts for blowers (used with set screw bearings) For bearings used in blowers (suffix code: ), a C internal ball clearance is recoended to reduce vibration and noise during operation. Therefore, the shaft tolerance classes shown in Table. are recoended for bearings with set screws. Refer to (. Internal bearing clearance ) Details of the internal C ball clearance. Table. Dimensional tolerance of shaft used for bearings (set screw type) for blowers unit: μm haft dia. () Dimensional tolerance of shaft h Over Incl. Max. Min. Max. Min j () Tolerance of inner rings of specification P is the suffix code that designates smaller bore tolerance which allows for a tighter fit with the shaft. This, in turn, reduces vibration and noise and dramatically increases bearing life. Nominal bearing bore dia. d () Table. Tolerance and tolerance values of inner rings of P suffix (unit: μm) Variation of tolerance of average bore dia. in plane dmp Unequal bore dia. in plane Vdsp Radial runout of inner ring Over Incl. Max. Min. Max. Max Kia Nominal bearing bore dia. d () Table. Tolerance and tolerance values of inner rings of IO standard (unit: μm) Variation of tolerance of average bore dia. in plane dmp Unequal bore dia. in plane Vdsp Radial runout of inner ring Over Incl. Max. Min. Max. Max Kia 4

17 DUT DIRT. Dust Resistant Units The FYH Dust Resistant Units consists of a variety of supplemental sealing options that function extremely well in the exclusion of foreign matter. These options can work well by themselves or in combination with each other. From food processing and agricultural to wash-down and mining and aggregate, the FYH Dust From food processing and agricultural to wash-down and mining and aggregate, the FYH Dust Resistant Units can stand up to the toughest contamination challenges. Triple-Lip eals (suffix code: L) The L seal consists of a stamped steel shield with a molded NR try-ply seal affixed to the inner portion of the shield, all of which is attached to the outer ring of the bearing. The triple-lip seal is excellent for resisting all types of contamination and is appropriate for low to moderate speeds. Tight Triple-Lip eals (suffix code: LT) The LT Triple-Lip seal fits tighter than the standard L seal. The rotating torque of the LT seal is approximately double that of the standard L seal, and it is appropriate where contamination or moisture are very high and rotating speeds are very low.

18 election Guide tamped steel and cast iron covers are available in open or closed versions in a complete range of sizes. They are easy to install and they offer great resistance to wet and dry contaminates, and shocks and heats. Covers protect the entire bearing insert from contamination and they also help to provide a safer working environment. tamped teel Open Covers Cast Iron Open Covers CKIDE GURD The nitrile rubber shields can be mounted on the backside of two and four bolt flange units and the equipment it is bolted onto. The backside guard protects your bearings from dust and moisture and help lead to longer bearing life in applications where this can be an issue. The nitrile rubber on the steel plate come without a drain slot and is designed for dust protection. ome applications where this product could be used include: aggregate applications, fertilizer spreaders, salt spreaders and agricultural applications where dirt can reach the backside of bearing units. The nitrile rubber on the 4 stainless steel plate with the drain slot is designed to protect your bearing units in applications that are exposed to moisture and where moisture or water build up can create issues. These backside guards can be utilized in food and beverage applications where they are being washed down as well as pharmaceutical applications. The stainless steel core is perfect for situations where regular steel can rust quickly.

19 ORIGINL DEIGNED ET CREW ULLET POINT The innovative FYH ullet Point set screw is a one piece ball point set screw which is designed to expand the threads of the screw as the point of the screw contacts the surface of the shaft.the resulting force creates superior holding power especially where vibration is present. Other set screws have larger contact areas with sharp edges at the point of the screw to bite into the shaft. However, these sharp edges damage more easily from vibration which creates a gap between the point of the set screw and the shaft. Once this gap is established, the set screw will begin to loosen. When the ullet Point set screw is tightened, the original shape of the point causes the threads of the screw to expand up to and beyond the elastic limit to achieve the maximum possible holding power. The thickness of the point is also designed to expand easily. This specialized design drastically reduces the potential for damage to both the set screw and shaft from normal use or for severe vibration, shock load, and high speed. Tightening Torque Expands Outward HFT CONTCT TRUE Concentric-LOC The FYH NU-LOC bearing grips the shaft more uniformly, which allows for degrees of equalized locking contact. Compared to set screw bearings, the roundness of the ball path on the NU-LOC bearings results in better operation and longer life. NU-LOC concentric locking collars are designed to prevent shafting from becoming marred or burred. single standard hex head cap screw can be tightened quickly and easily, and NU-LOC bearings can replace either setscrew or eccentric locking collar inserts. NU-LOC concentric locking collar with a single cap screw provides excellent holding power. The collar is installed over the slotted inner ring on the shaft concentrically. Quick & Easy Installation with a single hex cap screw. NU-LOC s standard tolerance specification is designed for air handring applications, and the greater roundness of the ball path enable the use of smaller internal ball clearance. The bore tolerance is also smaller since NU-LOC has the degrees of equalized locking contact. NU-LOC is not only good for the air handring applications, but great for the other applications as well.

20 Models Models. Model List Table. and Table. shows the models of FYH all earing Units and ball bearing inserts. Table. FYH all earing Units models Model Pillow lock Units 4-olt Flange Units Oval Flange Units Type earing bore dia. urface (fixing to shaft) Model code haft dia. (inch) () min. max. min. max. Dimension table () Pillow lock Units with set screws UCP 4 4 P. with eccentric locking collar NP / P. NP-E / / P. NPK / P. with concentric locking collar NCP / P.4 Tapered bore (with adapter) UKP 4 P. () Thick Pillow lock Units with set screws UCIP P. Tapered bore (with adapter) UKIP 4 P.4 () Tapped-ase Pillow lock Units with set screws UCP P. UCPN / P. with concentric locking collar NCP P. NCPN / P. (4) High-ase Pillow lock Units with set screws UCPH P.4 () Narrow Inner Ring earing Pillow lock Units with set screws P-RKP 4 P. with eccentric locking collar P-FP / P. with set screws PN-RKP / P. with eccentric locking collar PN-FP / P. () Light Pillow lock Units with set screws LP 4 P. with eccentric locking collar LP / 4 P. () Compact Pillow lock Units with set screws UP P. () Corrosion Resistant eries Pillow lock Units with set screws UCP-H / P.4 UCP-H / 4 P. UP- P. UCVP- P. UCVP-E P. UCVPN-E / P.4 () tamped teel Pillow lock Units with set screws PP P. with eccentric locking collar PP P. () 4-olt Flange Units with set screws UCF 4 4 P. UCF-E / P.44 with eccentric locking collar NNF / P.4 with concentric locking collar NCF / P. NCF-E / P. Tapered bore (with adapter) UKF 4 P.4 () quare Piloted 4-olt Flange Units with set screws UCF 4 4 P. Tapered bore (with adapter) UKF 4 P. () Narrow Inner Ring earing 4-olt Flange Units with set screws F-RKP 4 P.4 with eccentric locking collar F-FP / P.4 (4) Corrosion Resistant eries 4-olt Flange Units with set screws UCF-H / P. UCF-EH / P. UCVF- / 4 P. UCVF-E / 4 P. () -olt Flange Units with set screws UCFL 4 P.4 UCFL-E P. with eccentric locking collar NNFL / P.4 with concentric locking collar NCFL / P. NCFL-E / P. Tapered bore (with adapter) UKFL 4 P. () djustable -olt Flange Units with set screws UCF / P.4 () -olt Flange Units with set screws UCF P. (4) Narrow Inner Ring earing -olt Flange Units with set screws FL-RKP 4 P. with eccentric locking collar FL-FP / P. () Light -olt Flange Units with set screws TFD-H4RKP / P. with eccentric locking collar TFD-FH4P / P. () Light -olt Flange Units with set screws LF / P. with eccentric locking collar LF / P. () Compact -olt Flange Units with set screws UFL P.4 () Corrosion Resistant eries -olt Flange Units with set screws UCFL-H P. UCFL-EH P. UFL- P. UCVFL- / 4 P. UCVFL-E / 4 P.4 () Corrosion Resistant eries -olt Flange Units with set screws UCVF-E / P.

21 Model 4 4-olt Flange Cartridge Units tamped teel Flange Units Type Table. FYH all earing Units models (continued) earing bore dia. urface (fixing to shaft) Model code haft dia. (inch) () min. max. min. max. Dimension table () 4-olt Flange Cartridge Units with set screws UCFC 4 P. UCFCX-E 4 P. UCFCF / P.4 with concentric locking collar NCFC / P. Tapered bore (with adapter) UKFC P. () Narrow Inner Ring earing 4-olt Flange with set screws FC-RKP 4 P. Cartridge Units with eccentric locking collar FC-FP / P. () Corrosion Resistant eries 4-olt Flange Cartridge Units with set screws UCFC-H / 4 P.4 () tamped teel -olt Flange Cartridge Units with set screws PF / P. with eccentric locking collar PF / P. () tamped teel -olt Flange Units with set screws PFL / P. with eccentric locking collar PFL / P. Take-Up Units () Take-Up Units with set screws UCT 4 4 P.4 UCT-E / P.4 with eccentric locking collar NT-E / P. with concentric locking collar NCT / P. NCT-E / P.4 Tapered bore (with adapter) UKT 4 P. () Narrow lot Take-Up Units with set screws UCTR / P. () Corrosion Resistant eries Take-Up Units with set screws UCT-H P. UCT-EH P.4 (4) ection teel Frame Take-Up Units with set screws UCTH P. () Channel teel Frame Take-Up Units with set screws UCTL 4 P. UCTU 4 P. () teel Plate Frame Take-Up Units with set screws PTH P.4 NPTH P. Other Units () Cartridge Units with set screws UCC 4 4 P. Tapered bore (with adapter) UKC 4 P. () Hanger Units with set screws UCH P.4 Table. earing insert models Model all earing Inserts Type earing bore dia. urface (fixing to shaft) Model code haft dia. (inch) () min. max. min. max. Dimension table () UC inserts with set screws UC 4 4 P. UC inserts (tainless steel) UC- / P.4 () UK inserts Tapered bore (with adapter) UK 4 P. () NC inserts with concentric locking collar NC / P. (4) N inserts with eccentric locking collar N P. () inserts (Lightweight) with set screws 4 P. -RKP 4 P. () inserts (Lightweight) with eccentric locking collar / 4 P. -F / P. () U inserts. mall size with set screws U P. U inserts. mall size (tainless steel) U- P.4 () Cylindrical O.D. (with lubricating mechanism amd snap ring) with set screws ER / P. with concentric locking collar ERC / P.4 () Cylindrical O.D. with set screws R / 4 P. () tandard Cylindrical bore C 4 P. () Cylindrical O.D. with set screws -RK 4 P.4 with eccentric locking collar -F / P.4 () dapter HX P.

22 Models TNDRD Pillow lock Units. Models and Features FYH all earing Units are available in a variety of styles and sizes. Models and features of the all earing Units are shown below. Note ) Descriptions of codes for units with covers are shown in the table below. (coon to all the models) Diameter series Code Descriptions C, CD tamped steel plate cover type FC, FCD Cast iron cover type X C, CD From X to X: tamped steel plate cover type X and X: Cast iron cover type C, CD Cast iron cover type Pillow lock Units UCP NP-E NCP NP NPK UKP+H UCP is a pillow block unit with a rigid cast iron housing and two specially designed set screws in the inner-ring spaced at degrees for maximum holding power and reliability for a wide variety of applications and operating conditions. Duty: tandard, Medium, Heavy NP is a pillow block unit with an eccentric locking collar insert that provides a very secure grip to the shaft that becomes even more secure during continued operation. It is specifically used for singledirection/non-reversing rotation. Duty: tandard, Heavy NCP is a pillow block unit with a specially designed concentric locking collar that provides degrees of shaft contact. It produces a more concentric lock on the shaft compared to other locking styles and it functions very well for high speed applications. Duty: tandard UKP is a pillow block unit with a tapered-bore bearing insert that utilizes an adapter sleeve assembly to produce a highly concentric and secure lock on the shaft to reduce slippage and fretting corrosion even under adverse conditions. Duty: tandard, Medium, Heavy UCP-C, CD UKP-C, CD UCP-FC, FCD UKP-FC, FCD Thick Pillow lock Units UCIP UKIP+H UCIP is a pillow block unit with a highly rigid and rugged casting for particularly demanding applications. The two bolt holes are round for more accurate positioning and the strength ratings of the housing are substantially improved over standard pillow block housings. UK style is also available. Duty: tandard, Heavy

23 Tapped-ase Pillow lock Units UCP and UCPN are tapped-base pillow blocks with threaded bolt holes in the bottom of the housings. They are ideal for exact unit positioning and limited space applications. They are available in both inch and metric bolt-hole dimensions. N, NC & UK style are also available. Duty: tandard UCP UCPN NCP NCPN 4 High-ase Pillow lock Units UCPH is a pedestal pillow block unit with an exceptionally high mounting base. It is ideal for applications where a shouldered shaft could create interference with the mounting surface when using a standard pillow block unit. Duty: tandard UCPH Narrow Inner Ring earing Pillow lock Units P-RKP P-FP P-RKP is a lightweight bearing mounted pillow block unit which is ideal for limited space applications and light to moderate duty applications. P-FP with eccentric locking collar style is also available. PN-RKP is a lightweight bearing mounted tapped-base pillow block unit which is ideal for limited space applications and light to moderate duty applications. PN-FP with eccentric locking collar style is also available. Duty: tandard PN-RKP PN-FP

24 Models ( Pillow lock Units) Light Pillow lock Units LP is a compact and lightweight pillow block unit which is ideal for limited space applications and light to moderate duty applications. LP with eccentric locking collar style is also available. Duty: Light LP LP Compact Pillow lock Units UP is a light duty pillow block unit that is part of the Clean eries. It has a zinc-alloy housing for a high level of corrosion resistance and it is capable of accepting end covers to increase contamination resistance. Duty: Light UP UP-C, CD Corrosion Resistant eries Pillow lock Units UCP-H UCP-H UCVPN-E tamped teel Pillow lock Units PP UP- UCVP- UCVP-E PP UCP is a pillow block unit that is made entirely out of stainless steel components for the highest level of corrosion resistance for a mounted bearing unit. It is also pre-filled with food grade grease for food processing applications. Duty: tandard UP- is a light duty stainless pillow block unit that is part of the Clean eries. It has a stainless housing for a high level of corrosion resistance and it is capable of accepting end covers to increase contamination resistance. Duty: Light UCP is a tapped-base pillow block unit with threaded bolt holes in the bottom of the housings. It is made entirely out of stainless steel components for the highest level of corrosion resistance for a mounted bearing unit. It is ideal for exact unit positioning and limited space applications. It is also pre-filled with food grade grease for food processing applications. Duty: tandard UCVP and UCVPN is a pillow block unit with a corrosion resistant thermoplastic housing and the option of either a stainless steel bearing insert or a zinc chromate plated bearing insert. oth bearing inserts offer a high level of corrosion resistance and they are factory lubricated with food grade grease. Duty: tandard PP is a pillow block unit with a lightweight and compact stamped steel housing for light to moderate duty applications. PP with eccentric locking collar style is also available. Duty: Light

25 4-olt Flange Units 4-olt Flange Units UCF UCF-E NCF NCF-E quare Piloted 4-olt Flange Units NNF UKF+H UCF is a four-bolt flange unit with a rigid cast iron housing and two specially designed set screws in the inner-ring spaced at degrees for maximum holding power and reliability for a wide variety of applications and operating conditions. UK style is also available. Duty: tandard, Medium, Heavy NNF is a four-bolt flange unit with an eccentric locking collar insert that provides a very secure grip to the shaft that becomes even more secure during continued operation. It is specifically used for single-direction/non-reversing rotation. Duty: tandard NCF is a four-bolt flange unit with a specially designed concentric locking collar that provides degrees of shaft contact. It produces a more concentric lock on the shaft compared to other locking styles and it functions very well for high speed applications. Duty: tandard UCF is a piloted four-bolt flange unit available with a heavy duty bearing insert for a demanding operating environment. The pilot on the back of the housing allows for precise mounting where necessary. UK style is also available. Duty: Heavy UCF UKF+H Narrow Inner Ring earing 4-olt Flange Units F-RKP is a lightweight bearing mounted four-bolt Flange units which is ideal for limited space applications and light to moderate duty applications. F-FP with eccentric locking collar style is also available. Duty: tandard F-RKP F-FP 4 Corrosion Resistant eries 4-olt Flange Units UCF-H UCF-EH UCVF- UCVF-E UCF is a four-bolt flange unit that is made entirely out of stainless steel components for the highest level of corrosion resistance for a mounted bearing unit. It is also pre-filled with food grade grease for food processing applications. UCVF is a four-bolt flange unit with a corrosion resistant thermoplastic housing and the option of either a stainless steel bearing insert or a zinc chromate plated bearing insert. oth bearing inserts offer a high level of corrosion resistance and they are factory lubricated with food grade grease. Duty: tandard

26 Models Oval Flange Units -olt Flange Units UCFL UCFL-E NCFL NCFL-E NNFL UKFL+H UCFL is a two-bolt flange unit with a rigid cast iron housing and two specially designed set screws in the inner-ring spaced at degrees for maximum holding power and reliability for a wide variety of applications and operating conditions. UK style is also available. Duty: tandard, Medium, Heavy NNFL is a two-bolt flange unit with an eccentric locking collar insert that provides a very secure grip to the shaft that becomes even more secure during continued operation. It is specifically used for single-direction/non-reversing rotation. Duty: tandard NCFL is a two-bolt flange unit with a specially designed concentric locking collar that provides degrees of shaft contact. It produces a more concentric lock on the shaft compared to other locking styles and it functions very well for high speed applications. Duty: tandard djustable -olt Flange Units UCF UCF is an adjustable two-bolt flange unit with a rigid cast iron housing and two specially designed set screws in the inner-ring spaced at degrees for maximum holding power and reliability for a wide variety of applications and operating conditions. Duty: tandard -olt Flange Units UCF are three-bolt flange brackets with rigid cast iron housings and two specially designed set screws in the innerring spaced at degrees for maximum holding power and reliability for a wide variety of applications and operating conditions. They are available in both inch and metric bolt-hole dimensions. Duty: tandard UCF 4 Narrow Inner Ring earing -olt Flange Units FL-RKP is a lightweight bearing mounted two-bolt Flange units which is ideal for limited space applications and light to moderate duty applications. FL-FP with eccentric locking collar style is also available. Duty: tandard FL-RKP FL-FP 4

27 Light -olt Flange Units TFD is a compact and lightweight three-bolt flange unit with square bolt holes for carriage bolts and a ductile iron housing for added strength. It is ideal for limited space applications and light to moderate duty applications. with ductile iron housing Duty: Light TFD-H4RKP TFD-FH4P Light -olt Flange Units LF is a compact and lightweight two-bolt flange unit which is ideal for limited space applications and light to moderate duty applications. LF with eccentric locking collar style is also available. Duty: Light LF LF Compact -olt Flange Units UFL is a light duty two-bolt flange unit that is part of the Clean eries. It has a zinc-alloy housing for a high level of corrosion resistance and it is capable of accepting end covers to increase contamination resistance. Duty: Light UFL UFL-C, D Corrosion Resistant eries -olt Flange Units UCFL-H UCFL-EH UCVFL- UCVFL-E UFL- UCFL is a two-bolt flange unit that is made entirely out of stainless steel components for the highest level of corrosion resistance for a mounted bearing unit. It is also pre-filled with food grade grease for food processing applications. Duty: tandard UFL- is a light duty stainless two-bolt flange unit that is part of the Clean eries. It has a stainless housing for a high level of corrosion resistance and it is capable of accepting end covers to increase contamination resistance. Duty: Light UCVFL is a two-bolt flange unit with a corrosion resistant thermoplastic housing and the option of either a stainless steel bearing insert or a zinc chromate plated bearing insert. oth bearing inserts offer a high level of corrosion resistance and they are factory lubricated with food grade grease. Duty: tandard

28 Models ( Oval Flange Units) Corrosion Resistant eries -olt Flange Units UCVF is a three-bolt flange unit that is made entirely out of stainless steel components for the highest level of corrosion resistance for a mounted bearing unit. It is also pre-filled with food grade grease for food processing applications. Duty: tandard UCVF-E 4 4-olt Flange Cartridge Units 4-olt Flange Cartridge Units UCFC UCFCX-E UCFCF NCFC UCFC is piloted flange cartridge units with rigid cast iron housings and two specially designed set screws in the inner-ring spaced at degrees for maximum holding power and reliability for a wide variety of applications and operating conditions. The pilot on the back of the housing allows for precise mounting where necessary. UK, N styles are also available. Duty: tandard, Medium NCFC is a piloted flange cartridge unit with a specially designed concentric locking collar that provides degrees of shaft contact. It produces a more concentric lock on the shaft compared to other locking styles and it functions very well for high speed. Duty: tandard UKFC+H Narrow Inner Ring earing 4-olt Flange Cartridge Units FC-RKP is a lightweight bearing mounted 4-olt Flange Cartridge Units which is ideal for limited space applications and light to moderate duty applications. FC-FP with eccentric locking collar style is also available. Duty: tandard FC-RKP FC-FP Corrosion Resistant eries 4-olt Flange Cartridge Units UCFC is a four-olt Flange Cartridge Units that is made entirely out of stainless steel components for the highest level of corrosion resistance for a mounted bearing unit. It is also pre-filled with food grade grease for food processing applications. Duty: tandard UCFC-H

29 tamped teel Plate Flange Units tamped teel -olt Flange Cartridge Units PF is a round three-bolt flange unit with a lightweight and compact stamped steel housing for light to moderate duty applications. PF with eccentric locking collar style is also available. Duty: Light PF PF tamped teel -olt Flange Units PFL is a two-bolt flange unit with a lightweight and compact stamped steel housing for light to moderate duty applications. PFL with eccentric locking collar style is also available. Duty: Light PFL PFL Take-Up Units Take-Up Units UCT UCT-E NCT NCT-E NT-E UKT+H UCT is a wide-slot take-up unit suitable for use in a side-mount take-up frame. It has a rigid cast iron housing and two specially designed set screws in the inner-ring spaced at degrees for maximum holding power and reliability for a wide variety of applications and operating conditions. UK style is also available. Duty: tandard, Medium, Heavy NT is a wide-slot take-up unit with an eccentric locking collar insert that provides a very secure grip to the shaft that becomes even more secure during continued operation. It is specifically used for single-direction/non-reversing rotation. Duty: tandard NCT is a wide-slot take-up unit with a specially designed concentric locking collar that provides degrees of shaft contact. It produces a more concentric lock on the shaft compared to other locking styles and it functions very well for high speed applications. Duty: tandard UCTR is a narrow slot take up unit. It has a rigid cast iron housing and two specially designed set screws in the inner-ring spaced at degrees for maximum holding power and reliability for a wide variety of applications and operating conditions. Duty: tandard UCTR

30 Models ( Take-Up Units) Corrosion Resistant eries Take-Up Units UCT is a wide-slot take-up unit that is made entirely out of stainless steel components for the highest level of corrosion resistance for a mounted bearing unit. It is also pre-filled with food grade grease for food processing applications. Duty: tandard UCT-H UCT-EH ection teel Frame Take-Up Units UCTH is atake-up unit with section a steel frame. Duty: tandard UCTH 4 Channel teel Frame Take-Up Units UCTL teel Plate Frame Take-Up Units PTH UCTU NPTH UCTL is a Take-Up unit with a channel steel frame. Duty: tandard UCTU is a Take-Up unit with a channel steel frame. Duty: tandard, Heavy PTH is a Take-Up unit with a steel plate frame. Duty: tandard NPTH is a Take-Up unit with a steel plate frame. Duty: tandard Other Units Cartridge Units UCC Hanger Units UCH UKC+H UCC is a cartridge unit with two specially designed set screws in the inner-ring spaced at degrees for maximum holding power and reliability for a wide variety of applications and operating conditions. The cartridge housing allows for precise shaft mounting and expansion capability where necessary. UK, N, NC styles are also available. Duty: tandard, Medium, Heavy UCH is a hanger unit with a threaded-base for simple installation on a threaded pipe mounting configuration. It has two specially designed set screws in the inner-ring spaced at degrees for maximum holding power and reliability for a wide variety of applications and operating conditions. Duty: tandard

31 all earing Inserts UC inserts with set screws UC (X, ) tandard type UC (X, ) L Triple-lip seal type UC- tainless steel series Duty: tandard, Medium, Heavy Duty: tandard UC UC-L This deep grooved ball bearing insert with rubber seal and metal slinger comes pre-lubricated with FYH grease. This insert incorporates a wide inner ring design with FYH ullet Point setscrews as a standard, at degrees apart to affix the insert to the shafting. The setscrew locking design with wide inner ring is the most coon insert and can be used in a wide variety of applications. The spherical O.D. of the insert has both a grease groove as well as grease holes to re-lubricate the insert when needed. The UC insert can be ordered with a triple lip seal by using a L designation in the suffix. UC- UK inserts The UC- series incorporates the same design and dimensions as a standard UC insert but is constructed of grade stainless steel for wash down and other corrosive environments. These inserts come with food grade grease as a standard, and a primary used in food, pharmaceutical, fertilizer and demanding applications. with adapter UK (X, ) tandard type UK () L Triple-lip seal type Duty: tandard, Medium, Heavy UK UK+H This deep grooved ball bearing insert with rubber seal and metal slinger comes pre-lubricated with FYH grease. The UK series incorporates a tapered inner ring and uses corresponding adaptors to determine the bore size and affix it to the shaft. The UK series is perfect for applications where shock load can damage other locking devices. The tapered bore with adaptor provides true degree shaft contact that runs the entire length of the inner ring. The spherical O.D. has a grease groove and grease holes for relubrication. The insert and adaptor come as two separate items and must be ordered separately. The insert is also available in a triple lip design by adding the L designation to the suffix. UK-L NC inserts UK-L+H with concentric locking collar NC Duty: tandard NC The FYH NU-LOC bearing features a concentric locking collar that allows for degrees of locking contact. This deep groove ball bearing insert uses a grooved inner ring with a collar that incorporates a hex screw that is tightened to squeeze equally against the inner ring. The NU-LOC insert has a spherical O.D. and has grease grooves and grease holes for re-lubricating. The roundness of the ball path created by the NU-LOC bearing results in better operation and longer life. The collar is designed to prevent shaft marring and burring that can occur with other locking options.

32 Models ( all earing Inserts) 4 N inserts with eccentric locking collar N Duty: tandard, Heavy N This deep grooved ball bearing insert with rubber seal and metal slinger comes pre-lubricated with FYH grease. This insert incorporates a wide inner ring design with an eccentric locking collar for securing the insert to the shafting. The insert has grease holes and a grease groove on the outer ring for re-lubrication. The spherical O.D. allows this insert to be installed in a wide range of housings. When the insert is affixed to the shaft, the eccentric collars elliptical shape meshes with the elliptical surface of the inner ring. The turning of the inner ring locks the shafting in place and a setscrew is tightened to keep it from slipping. inserts with set screws Duty: Light -RKP This is a deep grooved ball bearing insert with spherical O.D. comes from the factory pre-lubricated with FYH grease. This bearing can be ordered in either re-lube style or sealed for life. The re-lube style has a grease groove and grease holes on the O.D. while the lubed for life does not. The series has the same load ratings as a UC bearing but has a narrow inner ring, and uses a one piece seal and slinger design rather than a separate seal and slinger. This insert affixes to the shafting using two set screws at degrees apart. To order this same bearing with a cylindrical O.D. use the designation. inserts with eccentric locking collar, -F Duty: Light -F This deep grooved ball bearing unit with spherical O.D. is the same as the type insert, but uses an eccentric locking collar for affixing to the shafting. This insert comes from the factory pre-lubricated with FYH grease. This bearing can be ordered in either re-lube style or sealed for life. The re-lube style has a grease groove and grease holes on the O.D. while the lubed for life does not. This series also has a re-lube backside style. The backside re-lube is designated by an F in the suffix to be compatible with others in the industry. When the insert is affixed to the shaft, the eccentric collars elliptical shape meshes with the elliptical surface of the inner ring. The turning of the inner ring locks the shafting in place and a setscrew is tightened to keep it from slipping. To order this same bearing with a cylindrical O.D us the designation. -FP

33 U inserts (mall size) with set screws U tandard type U- tainless steel Duty: Light U U- This deep groove ball bearing insert is intended for very light loads and is used in light duty conveying applications as part of our Clean eries. This bearing has a spherical O.D. and comes pre-lubricated from the factory. These inserts have a spherical O.D. with a wider inner ring and have no grease groove or grease holes for re-lubrication. Two setscrews at degrees apart affix this insert to the shafting. The U- bearing is constructed of stainless steel material and is used as part of our stainless Clean eries. The stainless material is superior in corrosion resistance compared to the normal clean series insert. ER inserts ER ERC with set screws, cylindrical O.D. lubricating mechanism, locating snap ring and snap ring groove ER, ERC Duty: tandard This deep groove ball bearing insert with a rubber seal and metal slinger come pre-lubricated with FYH grease. The ER series has a cylindrical O.D. with grease groove and grease holes outer ring for re-lubrication. The ER series uses two FYH ullet Point type setscrews at degrees apart to affix it to the shafting. The ER bearings have a snap ring on the outer ring to help make locating the bearing a simple task during installation. ERC with NU-LOC concentric locking collar style is also available. R inserts with set screws, cylindrical O.D. R Duty: tandard R This deep groove ball bearing insert with a rubber seal and metal slinger come pre-lubricated with FYH grease. The R series has a cylindrical O.D and has the same dimensions as the ER series but does not have a snap ring for locating or a grease groove and grease holes for re-lubrication. The R series uses two FYH ullet Point type setscrews at degrees apart to affix it to the shafting.

34 Models ( all earing Inserts) C inserts C Duty: Light The C series is a non-extending inner ring insert with a spherical outer-diameter which allows it to be mounted in a traditional housing. The bore tolerance is more precise than typical mounted bearings so press-fit shaft mounting can be accomplished. C, inserts with set screws, cylindrical O.D., -F Duty: Light The and insert series both have a cylindrical outer diameter for press-fit mounting directly into component machinery. They are not self-aligning or capable of being mounted into traditional housings. -RK -F dapter dapter HX The HX adapter series are for use in the tapered-bore UK series. Proper assembly of adapter sleeves can create excellent holding power on the shaft. HX

35 4 Rating Life of earings When ball bearing units are installed and operated on a piece of machinery eventually a failure will occur. The period of operation until the unit cannot be used due to failure is called the bearing life. earing failure is caused by two main reasons. The first is fatigue of bearing material, and the second is lubricant degradation. The life is figured on whichever fails first. Proper bearing lubrication will eliminate grease degradation and allow full bearing life to be achieved. If the bearing units are run without replenishment of the grease the bearing life will have to be factored by either the grease life or the bearing life. During installation, care must be taken not to damage the bearing. Proper bearing maintenance and lubrication will ensure long bearing life. 4. asic Rating Life and asic Load Rating 4.. asic rating life When a bearing is rotated under load the raceways and the rolling elements are continuously exposed to load. Damage, such as scaling (flaking or peeling), eventually appears on the material, and the total rotating frequency until the damage appears is called the fatigue limit of the bearing. Fatigue limit of the bearing can vary greatly even if the bearings have the same structure, dimensions, materials, machining methods, and are operated under the same conditions. To account for this variation, a group of the same bearings operating under the same conditions are tested, and the total rotating frequency of % of the bearings operating with no damage due to rotating fatigue (% reliability) is called the basic load rating. 4.. asic load rating Dynamic ratings are determined by placing a pure radial load on a radial bearing or by placing a central axial load on a thrust bearing. The dynamic rating is the load that the bearing will withstand for one million cycles before failure of the bearing. These ratings are referred to as the basic dynamic radial load rating (Cr) or the basic dynamic axial load rating (Ca). These values are indicated in the catalog as the basic dynamic radial load rating (Cr), and the value is shown in the dimensional table. 4. Calculation of Rating Life The relationship between the basic rating life, the basic dynamic load rating, and the dynamic equivalent load of the ball bearing is indicated in Formula (4.). If the ball bearing unit is being used at a fixed rotating speed, the life is indicated as time. This is shown in Formula (4.). (Total rotating frequency) (Time) L = Cr Pr Whereas, L: asic rating life, rotations Lh: asic rating life, hr Cr: asic dynamic load rating, N Pr: Dynamic equivalent load, N (see earing load ) n: Rotating speed, min (4.) Cr Lh = (4.) n Pr Calculation of the basic rating life using the life factor ( f h) and the speed factor ( f n) in Formula (4.) are shown below. Lh = f h (4.) Life factor f h = f n peed factor f n = Cr Pr n / = (.n) (4.4) / (4.) Values of f n, f h and Lh can be found using the nomogram of Fig. 4.. [all bearing] peed f n n ,,,,, Rating life f h Lh 4,,,,,,,,, Fig. 4. Relation between basic rating life (Lh) and rotating speed (n), speed factor ( f n), and life factor ( f h)

36 4 Rating Life of earings 4.. Correction of basic load rating due to temperature If a ball bearing unit is used at a relatively high temperature the physical composition of the bearing material is changed leading to decreased hardness. This decreased hardness leads to the basic dynamic load rating being reduced. Once the structure of the bearing material has been changed, it will remain this way for the life of the unit, even when it returns to room temperature. When using a ball bearing unit at ºC or more, the basic load rating must be corrected by multiplying the basic dynamic load rating shown in the dimensional table by the temperature factor shown in Table 4.. Table 4. Temperature factor earing temperature, ºC Temperature factor Corrected rating life The basic L rating life shown in Formula (4.) is the fatigue life of a bearing with % reliability however; there are circumstances where bearings need greater reliability. The bearing life may be extended by using special materials. Other conditions, including lubrication, may influence the bearing life. The corrected rating life is found by taking the basic rating life and taking the factors in Formula (4.) into consideration. Lna = a a a L (4.) Whereas, Lna: Corrected rating life, rotations earing characteristics and operating conditions are taken into consideration with reliability n% (breakage probability) L: asic load rating, rotations Life with % reliability a: Reliability factor... see () a: earing characterization factor... see () a: Operating condition factor... see () () Reliability factor a Table 4. shows the values used when a corrected bearing life that has less than a % breakage probability is necessary. Table 4. Reliability factor a Reliability, % Lna a La La. L4a. La.44 La. La. () earing characterization factor a The material make-up of a bearing can have an affect on its basic rating life. Factors that can influence the bearing include bearing material (type of steel), production procedures, and bearing design. earing characterization is shown as factor a. FYH ball bearing inserts use high quality vacuum degassed bearing steel as standard material, and this material allows for a longer rating life. For FYH ball bearing units, the bearing characterization factor a is (a = ). When bearings with special materials are used for a longer fatigue limit the characterization factor can be shown as a being greater than (a > ). () Operating condition factor a Operating conditions may directly influence the life of the bearing (especially proper or improper lubrication). The basic rating life should be corrected using the operating condition factor a. If lubrication is being maintained the factor a =. If excellent re-lubrication practices are being maintained the factor a > should be applied. If any of the following operating conditions are applicable the condition should be applied as a <. () Kinematic viscosity of lubricant during operation is low: all bearing: /s or less, Roller bearing: /s or less () Rotating speed is low: dmn:, or less Note: dm (Pitch dia. of ball set in ) n (Rotating speed) () Foreign matters are mixed in lubricant Even if the bearing characterization factor is improved i.e., a >, the life of the bearing must still be down-rated if the combination, a a >. 4

37 4.. Required lifetime of bearings t some point, the economical nature of a ball bearing begins to decline. The operating conditions, type of bearing used, and type of machine the bearing is used on all influence the operational life of the bearing. The required lifetime of the ball bearing is shown in Table 4.. Table 4. Required life time of ball bearing units (reference) Operating conditions Operated in short periods or intermittently Operated for several minutes or hours at a time, but less than hours per day Constantly operated for hours or longer per day or operated continuously for long periods Operated continuously for 4 hours, no fault is allowed Machines used Home electric appliances, electric tools, agricultural machinery, hoist, etc. Factory motor, ordinary gearing, etc. General machinery, blowers, etc. Power plants, mine drainage facility, etc. Required life time, hrs 4,,,,,,,, 4. Grease Life The grease life for ball bearing units is influenced by: the level of the load, rotating speed of the bearing, and the operating temperature. The grease life for ball bearing units being used under appropriate operating conditions can be found by the formula shown below. log L =. 4.4 dmn. (.. dmn) T Pr Cr. (4.) Whereas, L: Grease life, hr dm: Pitch dia. of ball set, (D + d) dm = D: Nominal bearing outer dia., d: Nominal bearing bore dia. n: Rotating speed of bearing, min Pr: Dynamic equivalent radial load, N (see earing load ) Cr: asic dynamic radial load rating of bearing, N T: Operating temperature of bearing, ºC pplicable conditions for the Formula (4.) are shown below. ) Operating temperature of bearing: T C To be applied if the following condition is satisfied: T If T is smaller than (T < ), following condition should be applied: T =. If T is larger than (T > ), contact FYH. ) Rotating speed of bearing: dmn To be applied if the following condition is satisfied: dmn 4 If dmn is smaller than. 4 (dmn <. 4 ), following condition should be applied: dmn =. 4 If dmn is larger than 4 (dmn > 4 ), contact FYH. ) Load condition of bearing: To be applied if the following condition is satisfied: Pr Cr. Pr Cr Pr Cr If is smaller than. ( <.), Pr Cr following condition should be applied: =. Pr Cr Pr Cr Pr Cr If is larger than. ( >.), contact FYH. Reference figure of grease life obtained by the Formula (4.) is shown in Fig. 4..

38 4 Rating Life of earings earing Load () earing load Pr Grease life L (hr),,,, Cr =.. Operating temperature T = C Loads that are applied to bearings come from a variety of sources. In addition to the primary load, other resultant loads include the weight of complementary objects including shafting, gears, pulleys, torsion from chain and belts, and so on. hock or dynamic load can also be derived from these sources. In many cases, these loads cannot be determined by a simple or single calculation; and since these loads often fluctuate in intensity, it is difficult to determine the exact magnitude of them prior to actual lab or field measurements on the machinery in question. However, in order to approximate the loads involved prior to putting a machine into operation, the technique shown below should be used. This technique uses multiplication factors that have been determined empirically from sample measurements taken on actual machines in operation. Rotating speed dmn ( 4 ). Loads pplied to earings () earing load Pr Grease life L (hr),,,, Cr =. Operating temperature T = C.. Load factor Even if the static radial load and the axial load can be accurately calculated, the actual loads are generally greater than the calculated figures. This is due to the presence of vibration and shock load during actual machine operation. To find the loads actually applied to a bearing, multiply the values determined for the static load by the following load factors. F = f w Fc (.). Rotating speed dmn ( 4 ) Whereas, F: Load actually applied to bearing, N Fc: Theoretically calculated load, N f w: Load factor (see Table.) () earing load Pr Grease life L (hr),,,, Cr =.. Operating temperature T = C Table. Load factor f w Operating conditions pplications f w Virtually no vibration or Electric machines. impact and instruments Ordinary operation (light impact) Great vibration and impact gricultural machines and blower Construction machines and grinders. Rotating speed dmn ( 4 ) Fig. 4. Relation of grease life to bearing load, rotating speed, and operating temperature (reference)

39 .. Loads from belts or chain drives The load calculated for the bearing is equal to the tensile load of the belt. However, this load must be multiplied by the load factor ( f w), which accounts for vibration and impact of the machine and a belt factor ( f b), which accounts for the vibration and impact generated through the belt. When calculating loads for a chain drive, use the same factor ( f b) as used for belt drives. Fb = M f w f b Dp. W = f w f b (.) Dp n Whereas, Fb: Load actually applied to pulley shaft or sprocket shaft, N M: Torque applied to pulley or sprocket, mn m W: Transmitted power, kw Dp: Pitch circle dia. of pulley or sprocket, n: Rotating speed, min f w: Load factor (see Table.) f b: elt factor (see Table.) Table. elt factor f b elt type f b Toothed belt. V belt. Flat belt (with tension pulley). Flat belt 4 Chain.... Load of gear transmissions Gear transmissions have a load in the tangential direction (Kt), a load in the radial direction (Kr), and an axial load (Ka). Different types of gears are calculated differently. The following is a sample of a calculation for an ordinary spur gear arrangement. flat spur gear will not support an axial load. Whereas, Kt: Load applied to gear in tangential direction (tangential line force), N Kr: Load applied to gear in radius direction (separating force), N Kg: ynthetic load applied to gear, N M: Torque applied to gear, mn m Dp: Pitch circle dia. of gear, W: Transmission power, kw n: Rotating speed, min α: Pressure angle of gear, º Note that the actual gear load must be found by multiplying the theoretical load by the load factor ( f w) obtained by taking into consideration the vibration and impact loads generated while the machine is in operation. The gear factor ( f g) is determined by taking into consideration the accuracy of machining and the finish of the gears. Fg = f w f g Kg (.) Whereas, Fg: Load actually applied to gear, N Kg: Theoretical synthetic load applied to gear, N f w: Load factor (see Table.) f g: Gear factor (see Table.) Table. Gear factor f g Gear type f g Precision gear. ( both pitch error and tooth profi le error should be. or less) Ordinary gear.. ( both pitch error and tooth profi le error should be. or less) () Load applied to gear in tangential direction (tangential line force) M Kt = = Dp. W Dpn (.) () Load applied to gear in radius direction (separating force) Kr = Kt tan α (.4) () ynthetic load applied to gear Kg = Kt + Kr = Kt secα (.)

40 earing Load. Distribution of earing Load Table.4 Radial load factor (X) and axial load factor (Y) In order to determine the radial load distribution to each bearing attached to a shaft, use the procedure shown below. Use the load factors shown in Table. to account for vibration and impact. standard radial ball bearing bears an axial load component in addition to the radial component. The total vectored load can be calculated by taking the square root of the sum of the squares of each load as shown in the previous calculation. l l F l l l l F F f Fa Fa / Fr e Fa / Fr > e e Cr X Y X Y F F l F = l F (.) l F = l F (.) F Remarks. Cr (basic static radial load rating) and f (factor) are shown in the dimensional tables.. If f Fa / Cr does not conform to the table above, fi nd by interpolation. Fig.. Distribution of load to bearings. Dynamic Equivalent Load In many cases, a bearing is exposed to the combined vector load of both radial and axial load components. It may also be used under more severe conditions such as vibration and shock load. In this case, a direct comparison to the dynamic load rating is not appropriate. In such a case, find the load equivalent to a direct radial load only and compare this with the basic dynamic load rating. The converted virtual load is called dynamic equivalent load (P)... Calculation of dynamic equivalent load The dynamic equivalent radial load (Pr) of a bearing that bears radial and axial loads as well as vibration and impact is found by the following formula. Pr = XFr + YFa (.) Whereas, Pr: Dynamic equivalent radial load, N Fr: Radial load, N Fa: xial load, N X: Radial load factor (see Table.4) Y: xial load factor (see Table.4)

41 .. verage dynamic equivalent load in the case of fluctuating loads If the level or direction of the load applied to a bearing is fluctuating, it is necessary to find the average dynamic equivalent load to calculate the bearing life. Table. shows the method of finding the average dynamic equivalent load under various types of fluctuating conditions. (4) ine curve fluctuation (upper half of sine curve) P P max P m Table. Calculation of average dynamic equivalent load in case of fluctuated load Σn it i () Graduated fluctuation Pm =. Pmax (.) P P Pm = p P P m P n n t n t n nt n P p nt + P p nt + + Pn p nntn nt + nt + + nntn (.) () Monotone fluctuation Whereas, Pm: verage dynamic equivalent load, N P: Dynamic equivalent load actuating for t hours at rotating speed of n, N P: Dynamic equivalent load actuating for t hours at rotating speed of n, N Pn: Dynamic equivalent load actuating for tn hours at rotating speed of nn, N Pmin: Minimum dynamic equivalent load, N Pmax: Maximum dynamic equivalent load, N Σniti: Total rotating frequency for t to ti hours P P m P max.4 asic tatic Load Rating and tatic Equivalent Load.4. asic static load rating Pm = Pmin + Pmax P min Σn it i (.) () ine curve fluctuation P P m Σn it i P max If a bearing is exposed to excessive static or impact load even when running at low rotational speed, partial permanent deformation occurs to the contact surface of the raceways of the bearing. The amount of permanent deformation increases with increased loads, and at some point, the bearing will no longer rotate smoothly. The basic static load rating of a bearing is the static load that generates the calculated contact stresses shown below at the center of the contact surfaces of the raceways. () elf aligning ball bearings... 4, MPa () Other ball bearings (mounted ball bearings included)... 4, MPa () Roller bearings... 4, MPa The total permanent deformation that occurs to the raceways and the balls under the above critical contact stresses is. times the diameter of the ball. In ball bearing units, this is indicated as the basic static radial load rating (Cr) and these values are shown in the dimensional tables. Pm =. Pmax (.)

42 earing Load.4. tatic equivalent loads tatic equivalent load is the equivalent of the combined (vectored) load converted to the equivalent direct radial load. The term static refers to no rotation or very little rotation. tatic equivalent radial load (Pr) can be calculated by using the formula below.. Example of pplied Calculation Example Distributing load Find the load applied to the bearing and bearing, if the radial load F (F =. kn) and F (F = 4. kn) are applied. Pr =. Fr +. Fa (.4) (.) Pr = Fr Whereas, Pr: tatic equivalent radial load, N Fr: Radial load, N Fa: xial load, N, F F.4. afety factor The static equivalent load that can be withstood by a bearing, in addition to the above considerations, is sometimes dependent upon unforeseen conditions in the operating environment. Therefore, a safety factor is always built in to insure success in the application. Cr f s = (.) Pr Whereas, f s: afety factor (see Table.) Cr: asic static radial load rating, N Pr: tatic equivalent radial load, N Table. afety factor f s (recoended) Operating conditions f s (Min.) High rotating accuracy is required eing rotated Ordinary operating conditions Impact. Not always being Ordinary operating. rotated sometimes oscillated conditions Impact, unevenly distributed load () Find the radial load F applied to the bearing by F, with Formula (.) and Formula (.). F =. =. (kn) In a similar manner, find the radial load F applied to the bearing by F. F =, 4. =. (kn) Remark: Negative load is the upward load. Radial load F applied to the bearing : F = F + F =. + (.) =. (kn) () In a similar manner to (), find the radial load F applied to the bearing. F =. =. (kn) F =, 4. =. (kn) F = F + F =. +. =. (kn) 4

43 Example Calculating load by V-belt transmission Find the load applied to the bearing and bearing when the shaft is driven by the V-belt, transmission power W is. kw (W =. kw), rotating speed n is min (n = min ), effective diameter of pulley Dp is (Dp = )., 4 () Find the load actually applied to the pulley shaft Fb with Formula (.). From Table., load factor f w is. ( f w =.), and the belt factor f b is. ( f b =.), from Table.. Fb =. W Dp n f w f b.. =.. = 4. (kn) () Find the load actually applied to the bearing and bearing (F and F) with Formulas (.) and (.). F = 4, 4. =. (kn) Example 4 Calculating bearing life Under the conditions shown in Example, find the bearing life Lh when a bearing is used for a blower with a rotating speed n,, min. () elect the load factor f w is. ( f w =.) from Table., and find the bearing load Pr. Pr = f w F =.. =. (kn) () The dynamic radial load rating of UCPJ (bearing UC), Cr, is. kn (Cr =. kn), and calculate the bearing life Lh with the Formula (4.). Cr Lh = = n Pr,, (hr).. () Calculate bearing life Lh with the nomogram shown in Fig. 4.. When the rotating speed n is, min (n =, min ), rotating factor f n is. ( f n =.). Next, find the life factor f h by speed factor f n, dynamic radial load rating of bearing Cr, and the bearing load Pr. Cr. Life factor f h = f n =. =.4. Pr From life factor f h, bearing life Lh, hours. F =, 4. =. (kn) Example Calculating dynamic equivalent radial load Find the dynamic equivalent radial load Pr when the radial load Fr,. kn (Fr =. kn), and the axial load Fa,. kn, (Fa =. kn) are applied to the pillow type unit UCPJ (bearing UC). () Find the radial load factor (X) and the axial load factor (Y) with using the static radial load rating Cr of UCPJ (bearing UC),. kn (Cr =. kn), and Table.4. Find the solutions of the following formulas: f Fa.. = =.4, e =.4 Cr. Fa. = =. > e (.4) Fr. Therefore, X =., Y =. () Find the dynamic equivalent radial load Pr with Formula (.). Pr = XFr + YFa = =. (kn) Example electing ball bearing units If a bearing is operated under the following conditions, select the flange type unit (UCF) with at least two years (, hours) or longer rating life: rotating speed of shaft n is, min (n =, min ), and radial load Fr is kn (Fr = kn). The radial load Fr includes the load factor and gear factor. () From the nomogram shown in Fig. 4., when life time Lh is, hr (Lh =, hr), life factor f h can be found as. ( f h.), and speed factor f n can be found as. ( f n.) when the rotating speed n is, min (n =, min ). f h Dynamic radial load rating Cr = Fr = f n. (kn).. () Find the flange type unit that meets the following condition: dynamic radial load rating Cr is. kn (Cr =. kn). For the series. UCFJ (dynamic radial load rating Cr is 4.4 kn (Cr = 4.4 kn)) can be selected. 4

44 earing Load Example electing pillow type units for low speed If a bearing is used for a dolly under the following conditions, select the pillow type unit (UCP) with, hours rating life: radial load Fr is kn (Fr = kn), and rotating speed is min. () Find the required dynamic radial load rating Cr with using Formulas (4.4) and (4.). peed factor f n = (.n) /p = (. ) /. Life factor f h = Lh /p, / =. f h Dynamic radial load rating Cr = Pr = f n. (kn).. () From Table., define safe factor f s as ( f s = ), and find the static radial load rating of bearing required Cr. Cr = f s Pr = = 4 (kn) Example Calculating grease life Find the grease life for pillow type unit UCP4J (bearing UC4) under the following conditions: radial load Fr is kn (Fr = kn), and rotating speed n is min (n = min ). Note that the radial load Fr includes load factor and belt factor. Operating temperature of the bearing should be 4 ºC. Find the grease life L using Formula (4.). log L =. 4.4 Pr dmn.. Cr (.. dmn) T = (... 4 ) = 4.4 L 4, (hr) () The unit is used for a dolly, and vibration or impact may occur. Thus, select UCPJ (Cr = 4. kn, Cr = 4. kn). Example Calculating bearing life in high temperature applications Find the bearing life if the heat resistant pillow type unit (UCPDK) is operated under the following conditions: operating temperature is ºC, radial load Fr is 4 kn (Fr = 4 kn), and the rotating speed n is min (n = min ). Note that the radial load Fr includes load factor and gear factor. () From Table 4., find the dynamic load rating Cr in the case that a bearing is used at ºC. Cr =.4. = 4. (kn) Find the bearing life Lh using Formula (4.). Lh = n Cr Pr, (hr) 4. = 4 Example Calculating life of bearing units in case of non-lubrication Find the life of a bearing unit in the case that it is operated under the conditions shown in Example, but without lubrication. () Find the rating life of bearings Lh using Formula (4.). Lh = n Cr Pr. = 4, (hr) () Compare the grease life L shown in Example to the rating life of bearings Lh. Then, grease life L is shorter than the bearing rating life. Therefore, life of a bearing unit should be the same as the grease life L, 4, hours (L = 4, hours). () If a bearing unit is operated at ºC, grease is degraded faster, and it cannot be used without lubrication. upply grease at intervals specified in Table 4.4. () If the shaft experiences axial expansion due to heat, install a fixed bearing unit on one end of the assembly and install floating bearing unit on the other side that allows the shaft to move freely through the bore of the bearing. More information is offered in ection. (see Design of shaft and base ). 4

45 Table. () Radial Load/peed Chart Normal Duty Unit : lbf llowable Radial Load at Various RPM HFT IZE L hours RPM (min - ) / / / / / / / / / / haded area non-contact seal is used. If the bearing with set screws is exposed to a heavy load (Pr / Cr >.), vibration, or heavy inpact, use a tighter shaft tolerance than normal. 4

46 earing Load Table. () Radial Load/peed Chart 44 Medium Duty Unit : lbf llowable Radial Load at Various RPM HFT IZE L hours RPM (min - ) / / / / / / / / haded area non-contact seal is used. If the bearing with set screws is exposed to a heavy load (Pr / Cr >.), vibration, or heavy inpact, use a tighter shaft tolerance than normal.

47 Table. () Radial Load/peed Chart Heavy Duty Unit : lbf llowable Radial Load at Various RPM llowable Radial Load at Various RPM HFT L RPM (min - ) HFT L RPM (min - ) IZE hours 4 4 IZE hours / / / haded area non-contact seal is used. -/ If the bearing with set screws is exposed to a heavy load (Pr / Cr >.), vibration, or heavy inpact, use a tighter shaft tolerance than normal. all earing Life Calculations The relationship between the basic rating life, the basic dynamic load rating, and the dynamic equivalent load of the ball bearing is indicated in Formula. If the ball bearing unit is being used at a fixed rotating speed, the life is indicated as time. This is shown in Formula... asic Rating Life rotations Rated Life (hr) asic Dynamic Load Rating (kn) Dynamic equivalent Load (kn) peed (min-¹) asic Loads (lbf) IZE Dynamic Load (Cr) tatic Load (Cr) UC 4 UC 4 UC 4 UC4 4 UC UC 4 4 UC 4 UC 4 4 UC 4 UC 4 UC UC 4 UC UC4 UC UC UC UC asic Loads (lbf) IZE Dynamic Load (Cr) tatic Load (Cr) UC 4 4 UC UC 44 UC 4 UC UC UC UC 4 4 UC 4 UC4 4 4 UC 4 UC UC UC 4 UC 44 UC UC UC 4 4 UC4 4 4 UC 4 UC asic Loads (lbf) IZE Dynamic Load (Cr) tatic Load (Cr) UCX 4 4 UCX 4 UCX 4 4 UCX 4 UCX 4 UCX UCX 4 UCX UCX UCX4 UCX UCX UCX UCX 4 4 UCX 4

48 llowable Rotating peed llowable Rotating peed. llowable Rotating peed The rotational speed of a bearing is limited by the temperature increase, mainly due to friction. When the bearing reaches the speed limits shown below, it will seize if operated continuously at these levels. The limiting rotational speed is the maximum speed at which the bearing can be safely operated continuously. These allowable rotational speeds of a ball bearing unit are dependent upon the dimensions of the bearing, type of seal, and the fit of the bearing inner ring to the shaft. Table. shows the standard allowable rotating speeds of ball bearing units. Table. llowable rotating speed of ball bearing units (standard value) ore dia. code UC type bearing, UC- type bearing, UK type bearing, NC type bearing, N type bearing, ER, R type bearing tandard type, heat resistant (DK), cold resistant type (DK) tandard blowers (), Heatresistant (DK) Triple lip seal type (L) Non contact seal (K), Non contact seal for blowers () type bearing type bearing Unit: min U type bearing U- type bearing Diameter series ) Diameter series ) Diameter series ) Diameter Diameter series ) series ) X X X,,,,,,,,,,,,,,,,, 4,,,,,, 4, 4,,,,4,, 4, 4,,,,4,, 4,,,,,4,,,,,,,, 4, 4,,,,, 4 4, 4, 4,,,,,4 4 4,,,,,,,,,,4,,, 4 4,,,,,, ,,, 4,,, ,,,,,, 44 4,,,,,, 4,,,4,,, 4,,4,,,,4 4,4,,,4,,,,,,,,, 4, 4,,,,4 Remarks. llowable rotating speed of the units with covers is % of the value shown in the table above.. If a bearing unit is used with an excessively loose fi t, allowable rotating speed must be corrected by multiplying it by the fitting factor f c shown in Table... The basic bearing size number consists of the duty code (, X, or ) followed by the inner ring size code (,, 4, etc.) 4

49 . Rotational peed djustment Due to haft Fit marginal degree of clearance is typically used to facilitate easy installation of a bearing to a shaft. The amount of clearance between the bearing and shaft must be factored in to determine the maximum allowable rotational speed, and as rotational speed is increased, the amount of clearance must be decreased. Table. shows the factor that must be used to correct the allowable rotational speed. The maximum rotational speed is determined by multiplying the speed found in Table. by the factors below. This table includes the multiplying factors for set screw bearings as well as bearings with adapters and eccentric locking collars. Due to the characteristics of bearings with adapters, a loose fit, h or h, is acceptable. earings with eccentric locking collars function optimally with less clearance and therefore, an h or j fit is recoended to achieve the maximum allowable speed. Table. Fitting factor of ball bearing units f c (recoended) Fitting factor f c Type of ball haft tolerance range class bearing units h, j j h h h h With set screws tandard type... L type (uffix code: L). Heat resistant type (uffi x code: DK). Cold resistant type (uffi x code: DK). For high speed (uffix code: K).. For blower (uffix code: ).. With adapters With eccentric locking collar NU concentric locking collar Operating Temperature and earing pecifications. Operating Temperature Range The operating temperature of a ball bearing unit depends on the type of grease, the material of the seal, and the internal clearance of the bearing. FYH all earing Units are available in high temperature (DK, DK) and low temperature (DK) series, in addition to the standard models, to allow selection of the correct bearing for your operational temperature (see Table.). The correct unit must be chosen for the desired temperature range, and it is equally important to use the appropriate grease according to the specified schedule.. Operating Temperature and Internal Clearance of earings When bearings are operated in a high ambient temperature environment, or when the operating temperature is high because of rotational speed, differential expansion rates occur within the bearing components. This causes higher friction, grease breakdown, and eventual seizure. If the temperature difference between the inner and outer ring is known, or can be approximated, then the following Formula (.) may be applied. Under these conditions, decrease in the internal clearance must be calculated, and the internal clearance of bearing needs to be selected properly. t = α De t (.) Whereas, t: Decrease in the internal clearance of bearings depending on the difference in the temperatures of the bearing inner ring and the bearing outer ring can be found by formula, α: Line expansion factor of bearing steel,. De: Raceway dia. of bearing outer ring, Diameter series, X De. D Diameter series De. D D: Nominal bearing outer dia., t: Difference in temperatures of bearing inner ring and outer ring, ºC If a ball bearing unit is used in a high temperature environment, an abnormal load will result due to thermal expansion of the shaft. This must be compensated for by allowing free movement of one side of the shaft. (ee Design of haft and ase ) 4

50 trength of Housings trength of Housings FYH bearings can withstand very high loads due to the use of only high quality material and excellent design. However, when high static or impact loads are encountered, the load capacity of the bearing must be determined. The housing design is such that it can withstand loads from any angle; however the bearing is strongest with a direct downward load through the base of the unit. For loads in other directions, the allowable load must be determined specifically for the direction in question. Rigidity of the base and flatness of the mounting surface also influence the housing strength. The equipment designer or installer must examine and perform calculations for the complete supporting structure of the bearing.. trength of Cast Iron Housings lthough gray cast iron has many superior characteristics, it may fail under impact loads, particularly in a low temperature environment. Table. shows the applicable design safety factors for gray cast iron. Fig.. to. show the static rupture strength of the various housing types. Table. afety factor of gray cast iron products (recoended) Property of load afety factor of gray cast iron tatic load 4 With vibration With impact. trength of Ductile Cast Iron Housings The high-strength ductile cast iron series has the same shape and dimensions as the standard gray cast iron series, but is acceptable in environments where highstrength is required. Table. shows safety factors of the load on ductile cast iron housings, and tables. to. show the approximate rupture strength of pillow type, flange type, and take-up type housings. Table. afety factor of ductile cast iron (recoended) Property of load afety factor of ductile cast iron tatic load With vibration With impact tatic rupture strength kn 4 4 P P P P P P P Direction Direction C Direction Direction D Direction E Housing No. Remarks The graph value Direction of is a reference value. tatic rupture strength kn tatic rupture strength kn 4 PX PX,,4,, 4 P PX, D C PX PX P PX Housing No. D C E PX4 PX PXPX Direction Direction C Direction Direction D Direction E Direction Direction C Direction Direction D Direction E 4 Fig.. P P P P P P Housing No. tatic rupture strength of pillow type housing (P)

51 D C E tatic rupture strength kn IP Direction Direction C Direction Direction D Direction E tatic rupture strength kn,4,, 4 IP Direction Direction C Direction Direction D Direction E IP IP IP IP IP IP IP IP IP IP IP IP Housing No. Housing No. Fig.. tatic rupture strength of thick pillow type housings (IP) C E C E P Direction PH Direction tatic rupture strength kn 4 4 Direction C Direction Direction E tatic rupture strength kn 4 4 Direction Direction C Direction E P4 P P Housing No. P PH4 PH PH Housing No. PH Fig.. tatic rupture strength of tapped base pillow type housings (P) Fig..4 tatic rupture strength of High-ase pillow type housings (PH) 4

52 trength of Housings E E tatic rupture strength kn F Direction Direction E tatic rupture strength kn 4 4 FL Direction Direction E F4 F F F Housing No. F F FL4 FL FL FL Housing No. FL tatic rupture strength kn FX Direction Direction E tatic rupture strength kn 4 FLX Direction E Direction FX FX FX FX4 Housing No. FX FLX FLX FLX FLX FLX FLX Housing No. tatic rupture strength kn,4,, 4 F F F F F Housing No. F F Direction Direction E Fig.. tatic rupture strength of square flange type housings (F) tatic rupture strength kn FL FL FL FL FL FL FL Direction Direction E Housing No. Fig.. tatic rupture strength of oval flange type housings (FL)

53 P, PX, D C E tatic rupture strength kn 4 4 TX T T tatic rupture strength kn 4 PH4 Direction Direction C Direction Direction D Direction E Q4 Q Q Q Q Q Housing No. Q Q PH4 PH4 PH4 PH4 PH4 PH4 Housing No. Fig.. tatic rupture strength of take-up type housings (T), PXH4 Direction tatic rupture strength kn 4 Direction C Direction Direction D Direction E PXH4 PXH4 PXH4 PX4H4 Housing No. PXH4 tatic rupture strength kn Fig..,,,, PH4 PH4 PH4 PH4 PH4 PH4 PH4 Housing No. Direction Direction C Direction Direction D Direction E tatic rupture strength of ductile cast iron pillow type housings (PH4)

54 trength of Housings E E tatic rupture strength kn 4 FH4 Direction Direction E tatic rupture strength kn FLH4 Direction Direction E F4H4 FH4 FH4 FH4 Housing No. FH4 FL4H4 FLH4 FLH4 FLH4 Housing No. FLH4 tatic rupture strength kn 4 4 FXH4 Direction Direction E tatic rupture strength kn 4 FLXH4 Direction E Direction FXH4 FXH4 FXH4 FX4H4 Housing No. FXH4 FLXH4 FLXH4 Housing No. FLXH4 tatic rupture strength kn,,,, FH4 FH4 FH4 FH4 FH4 FH4 FH4 Housing No. Fig.. tatic rupture strength of ductile cast iron square flange type housings (FH4) Direction Direction E tatic rupture strength kn, 4 Fig.. FLH4 FLH4 FLH4 FLH4 Housing No. FLH4 FLH4 FLH4 Direction Direction E tatic rupture strength of ductile cast iron oval flange type housings (FLH4)

55 tatic rupture strength kn 4 TXH4 TH4 TH4 Q4 Q Q Q Q Q Q Q Housing No. Fig.. tatic rupture strength of ductile cast iron take-up type housings (TH4)

56 trength of Housings. trength of tamped teel Housings The precisely formed stamped steel housing is very rigid, but it is not as strong as cast iron or cast steel housings. Therefore, it will not support loads to the maximum rating of the bearing itself and must be down-rated per Table.. Table. llowable load of steel plate housings (recoended). trength of Die-cast Housings The clean series housing is made of die-cast zinc alloy, but the zinc alloy material is not as strong as cast iron or cast steel. Table. shows safety factors for die-cast zinc alloy, and Fig.. and. show the basic values of the static rupture strength of the die-cast zinc alloy housing. Table. afety factor of zinc alloy die-cast products Load direction Radial xial llowable load of stamped steel housings pprox. / of basic dynamic radial load rating of bearing (Cr) pprox. / of basic dynamic radial load rating of bearing (Cr) Property of load afety factor of die-cast products tatic load With vibration With impact.4 trength of tainless teel Housings FYH supplies stainless steel housings (P-H, P-H, F- H, FL-H, T-H, P, FL). Table.4 shows the safety factors for stainless steel products. s for the basic values of the static rupture strength of P-H, P-H, F-H, FL-H, T-H, FC- H type housings, apply P of Fig.., P of Fig.., F of Fig.., FL of Fig.. and T of Fig... s for the basic values of the static rupture strength of FC-H housings, apply F of Fig... For the basic values of the static rupture strength of the P and FL type housings, see P~P of Fig.. and FL~FL of Fig.. and multiply them by. respectively. Table.4 afety factor of stainless steel products tatic rupture strength kn P C E Direction Direction C Direction E Property of load afety factor of stainless steel products tatic load With vibration With impact P P P4 P Housing No. Fig.. tatic rupture strength of clean housings (P) E FL tatic rupture strength kn Direction Direction E FL FL FL4 Housing No. FL Fig.. tatic rupture strength of clean housings (FL) 4

57 . tatic Rupture trength of Plastic Housings E C E D tatic rupture strength kn 4 4 VP Direction Direction C Direction Direction E VP4 VP VP VP VP Housing No. Fig..4 tatic rupture strength of plastic housings (VP) tatic rupture strength kn 4 4 VFL VFL4 VFL VFL VFL Housing No. VFL Direction Direction Direction D Direction E Fig. tatic rupture strength of plastic housings (VFL) Note: The fi gure shows the average static rupture strength of housings. The correct safety factor should be considered to properly account for combined load in various directions at room temperature ( ºC ± ºC). E tatic rupture strength kn VF Direction 4 4 Direction E VF4 VF VF VF VF Housing No. Fig.. tatic rupture strength of plastic housings (VF)

58 Design of haft and ase Design of haft and ase. Design of haft For optimal performance of a ball bearing unit, and for maintenance-free operation for an extended period of time, proper shaft selection is very important. The shaft should be straight, of sufficient tensile strength, and free of burrs and scratches... Dimensional accuracy of shaft () Dimensional tolerance of shaft used for set screw bearings For bearings with set screws, a relatively looser class of fit makes assembly easier and is perfectly acceptable at low operating speeds. The clearance between the bore of the bearing and the shaft must be decreased as the rotational speed is increased. Table. shows the guidelines for the tolerance class for the rotational speed of bearings with set screws. If the bearing with set screws is exposed to a heavy load (Pr / Cr >.), vibration, or heavy impact, use a tighter shaft tolerance than normal. Table. shows the tolerances for tight fits. Table. shows the recoended roundness and cylindricity for shafting. Table. Dimensional tolerance of shaft used for cylindrical bore bearing with set screws (recoended) (clearance fit or intermediate fit) Unit: μm haft dia. Dimensional tolerance of shaft () j h h h Over Incl. Max. Min. Max. Min. Max. Min. Max. Min pplicable rotating speed dn ) Over, Over,, incl., Over,, incl., Note ) dn = d (bearing bore dia., ) n (rotating speed, min ) Incl., Table. Dimensional tolerance of shaft used for cylindrical bore bearing with set screws (recoended) (intermediate fitting or tight fitting) Table. Recoended accuracy of shaft used for ball bearing units Unit: μm Unit: μm haft dia. Dimensional tolerance of shaft () k k m Over Incl. Max. Min. Max. Min. Max. Min haft dia. () Over Incl. Tolerance of shaft roundness and cylindricity (max.)

59 () Dimensional tolerance of shaft used with tapered bore bearings ince tapered bore bearings are fixed to the shaft with an adapter, a looser fit is allowable since the adapter sleeve provides excellent concentricity. This makes mounting of the bearing to the shaft much easier. Table.4 shows the dimensional tolerance of the shaft used with tapered bore bearings (with adapters). Table.4 Dimensional tolerance of shaft used for tapered bore bearings (with adapters) (recoended) Unit: μm haft dia. Dimensional tolerance of shaft () h h Over Incl. Max. Min. Max. Min () Dimensional tolerance of shaft with eccentric locking collar Eccentric locking collar bearings have greater clearance (more eccentricity) between the shaft and the bore of the bearing when installed. Therefore, the shaft tolerances must be tighter (h or j) to reduce the clearance (eccentricity). The same clearance fits are recoended as with blower bearings as shown in Table... (4) Dimensional tolerance of shaft used for concentric locking collar Regarding the shaft used for concentric locking collar bearings, the same clearance (h or j) fits are recoended as with air handling bearings as shown in Table.... Dimensions of shouldered shafts When using a set screw or eccentric locking collar bearing that is exposed to a high axial load, excessive vibration, or impact, a shouldered shaft may be used. The inner ring of the bearing is then tightened in place with a locknut, if the shaft is threaded, or with a locking ring otherwise. However, if after mounted units used a shouldered shafts, between the inner ring end face and shouldered shafts, on clearances of or more is recoended. Table. shows the shoulder diameter and the fillet radius of the shouldered shaft. Table. Recoended shoulder diameter and fillet radius of a shouldered shaft ore dia. code Nominal bearing bore dia. d a houlder dia. da r a Diameter eries ) Diameter eries ) UC, UCX UC Fillet roundness radius ra (max.) houlder dia. da Fillet roundness radius ra (max.) The basic bearing size number consists of the duty code (, X, or ) followed by the inner ring size code (,, 4, etc.)

60 Design of haft and ase.. High temperature applications In general, two bearing units are used per shaft. If the distance between the bearings is small, or if the temperature change of the shaft is small, both bearings may be fixed in position. However, if the distance between the bearings is large and the shaft is exposed to heat, then only one bearing should be fixed and the opposing bearing must be free to float in the axial direction. This is because shaft expansion due to temperature change of the shaft causes a high axial load and can cause failure of fixed bearings. The amount of shaft expansion due to temperature change may be calculated by using Formula (.). = α t l (.) Whereas, : Expansion of shaft, α: Linear expansion coefficient of shaft in the case of ordinary steel, ~ t: Temperature increase, ºC l: Installation distance of unit, Proper installation procedures for a shaft exposed to temperature changes are shown below. () Installation with a dog point set screw on the free side To accoodate shaft expansion in the axial direction, the bearing must be installed so that the shaft can move freely through the bore in either axial direction. To accomplish this, the shaft must be grooved for a full dog point set screw (suffix code: G). This should be done on the free side only. The dog point screw allows free movement in the axial direction and provides force to rotate the bearing in the radial direction. Fig.. shows an example of the structure of a bearing with a key groove on the shaft and a full dog point set screw. Table. shows the dimensions of the key groove for the full dog point set screw. Note that the full dog point set screw in the image is also capped so that it may be tightened against the bearing, not the shaft. full dog point set screw with a jam nut will also work to achieve this function. The tolerance class of the shaft to be used is h. If the temperature of the shaft is higher than that of the bearing, then a looser fit tolerance class is specified. When using this method to allow for free expansion, there is the possibility of fretting between the shaft and the inner race. In order to prevent fretting, a high temperature grease must be applied to the inner ring of the bearing and the shaft prior to installation. Full dog point set screw Fig.. Use on free side with full dog point set screw Table. Dimensions of key groove for full dog point set screw (use on free side) J K Full dog point set screw Nominal size of set screw Dimensions of key groove pplicable nominal bearing code () J K UC UCX UC M. 4 X, M XX M.. XX, M. XX 4 M4. X, M. X M. 4 M., llowable tolerance of key groove dimension K (Recoended value: ~+.)

61 () Installation of cartridge type units on the free side If the rotational speed is high or if the bearing is exposed to high vibration, the cartridge type unit is recoended on the free side. In this case, the housing of the cartridge unit is free to move axially within the mounting bore and the bearing insert is rigidly attached to the shaft. Fig.. shows the required structure for the cartridge type unit on the free side... Mounting cartridge type units in high temperature applications Cartridge units are designed to fit into an accurately bored cylindrical opening in the mounting base. Under ordinary operating conditions, H is an adequate choice for the tolerance class of the cylindrically bored hole. In instances where both the bearing and the shaft are heated during operation, select G as the tolerance class of the cylindrical bore. If the bearing is exposed to excessive vibration or impact, then an even tighter tolerance class must be specified. Table. shows the dimensional requirements for the cylindrical bore. Table. Dimensional tolerance of cylindrical bore for mounting cartridge type units (recoended values) Unit: μm Fig.. Use of cartridge type units on free side If, in addition to the expansion of the shaft, the ball bearing itself is exposed to heat, then a calculation of the decrease in internal clearances of the bearing must be made. The appropriate bearing internal clearance must be specified. (see Operating temperature and bearing specifications ).. Mounting ase Design.. Rigidity of base and flatness of mounting urface If rigidity of the base on which a ball bearing unit is to be mounted is not sufficient, or if the flatness of the mounting surface is poor, then vibration or abnormal noise may occur during operation. This may lead to premature bearing failure since the strength of the housing is diminished from improper support. The mounting surface must be accurately machined to eliminate deformation of the housing. Fig.. shows the recoended values for flatness of the mounting surface on which the ball bearing unit is to be installed. Nominal bore dia. of cylindrical bore () Dimensional tolerance of cylindrical bore H G Over Incl. Max. Min. Max. Min Installation of take-up units take-up unit is positioned between two guide rails and enables linear adjustment by means of the threaded rod and bolt. Table. shows the dimensions of the guide rail, adjuster bolt, and fixed nut. L L Max.: L /, Fig.. Flatness of mounting surface of base (recoended value)

62 Design of haft and ase Table. Dimensions relative to installation of take-up type units (recoended values) r H H r±. φd Tapered pin Nominal bearing code T4 T T T Dimensions of guide rail r Hr H (Reference) Dimensions of adjuster bolt and round nut d D 4 4 T T T 4 4 T 4 T T T4 T 4 T 4 4 T 4 4 TX TX 4 TX TX TX 4 4 TX 4 TX TX TX TX4 4 TX 4 TX TX 4 4 Remark This table is also applicable to stainless steel housings. Dimensions of adjuster Nominal Dimensions of guide rail bolt and round nut bearing code H r Hr d D (Reference) T T 4 T 4 T 4 4 T T 4 T 4 T 4 T T4 4 4 T 4 T 4 4 T T T 4 T T 4 4 T 44 T4 4 T 4 T 4 4. Dowel Pins for ccurate Unit Mounting The pillow type, square flange type, and oval flange type housings all have a dowel pin seat on the mounting base. If accurate positioning of the housing is required, then the bottom of the housing may be drilled for dowel pins which fit into corresponding holes in the mounting surface. The dimensions for the hole and pin sizes can be found in ppendix table in the back of the catalog.

63 Nomenclature Nomenclature of FYH all earing Units conform to JI, and comprise the bearing unit model code (comprising bearing model code and housing model code), diameter series code, bore diameter. code, accessory code, and special code. UC P J L UK P J CD + HX UC F J L FD DK G Housing special code (Table.) earing special code (Table.) ccessory code (Table.) Fitting code (Table.) ore dia. code (Table.4) Diameter series code (Table.) Housing model code (Table.) earing model code (Table.) earing No.: Housing No.: earing No.: UK+HX Housing No.: PJE teel plate cover No.: (Open type) C-x4 (Closed type) D- earing No.: Housing No.: Cast iron cover No.: UCL PJ UCLDKG FJE (Closed type) FD Remark The above code shows an example of nomenclature structure. It may depend on the bearing unit model. Table. earing model code Table. Housing model code (continued) earing model code UC UC- UK N NC U -F U- ER ERC R -F Housing model code P IP P PN PH LP P P-H P-H Details with set screws with set screws (stainless steel series) Tapered bore with adapter sleeve with eccentric locking collar with concentric locking collar with set screws (lightweight type) with set screws (clean series) with eccentric locking collar (lightweight type) with eccentric locking collar, Lubricating mechanism (lightweight type) with set screws (stainless steel series) with set screws, cylindrical O.D., Lubricating mechanism, snap ring with concentric locking collar, cylindrical O.D., Lubricating mechanism, snap ring with set screws, cylindrical O.D. with set screws, cylindrical O.D. with eccentric locking collar, cylindrical O.D. (lightweight type) Table. Housing model code Details Pillow type Thick pillow type Tapped-ase pillow Tapped-ase pillow High-ase pillow type Lightweight pillow type Pillow type (clean series) Pillow type (stainless steel series) Tapped-ase pillow (stainless steel series) Housing model code VP VPN P PP F NF FL F F FC FCF F FL TFD-H4 LF F-H FL-H FL FC PF PFL VF VFL VF T TR T-H TH TL TU PTH NPTH Details Pillow type (thermoplastic series) Tapped-ase pillow (thermoplastic series) Pillow type (stainless steel series) tamped steel pillow type quare four-bolt flange type quare four-bolt flange type Oval two-bolt flange type djustable oval two-bolt flange type Three-bolt flange type Round flange cartridge type Round flange cartridge type quare four-bolt cartridge fl ange type Oval two-bolt flange type (clean series) Three-bolt flange type (Ductile cast iron) Lightweight oval two-bolt flange type quare four-bolt flange type (stainless steel series) Oval two-bolt flange type (stainless steel series) Oval two-bolt flange type (stainless steel series) Round flange cartridge type (stainless steel series) tamped steel plate round three-bolt flange type tamped steel plate oval two-bolt flange type quare four-bolt flange type (thermoplastic series) Oval two-bolt flange type (thermoplastic series) Three-bolt flange type (thermoplastic series) Take-up type Narrow slot Take-up type Take-up type (stainless steel series) ection steel frame take-up type Light channel steel frame take-up type Channel steel frame take-up type teel plate frame take-up type teel plate frame take-up type

64 Nomenclature Table. Housing model code (continued) Table. earing special code Housing model code C H ore dia. code Cartridge type Hanger type Table. Diameter series code Details Diameter series code Details mall size light duty Normal duty X Medium duty Heavy duty Table.4 ore dia. code Details Nominal bearing bore dia. Nominal bearing bore dia. Nominal bearing bore dia. Nominal bearing bore dia. Nominal bearing bore dia. 4 and above Fitting code J H K ccessory code C ) D ) FC FD L (ore dia. code) = Nominal bearing bore dia. () (bore dia. code) / = nominal bearing bore dia. (inch) (in this case, / = inch =. ) s for the bore dia. inch series bearing. Table. Fitting code Details Tolerance class of spherical bore of the housing is J (not shown where the spherical bore diameter exceeds ) Tolerance class of spherical bore of the housing is H Tolerance class of spherical bore of the housing is K Table. ccessory code Details Cover, open type Cover, closed type Cast iron cover, open type Cast iron cover, closed type Triple-lip seal type Note ) tandard specifications of codes C and D are as shown below., XX...teel plate cover XX,...Cast iron cover Item earing special code Details Grease D U-RET EDM- D HM D Demnum L- et G4 Cone point crew G Capped full dog point eal K ilicone rubber K Non-contact type ealing P Without seal, slinger Device P4 Without seal Others ir handling fi t,% noise check, the anti-rotation pin For blower (seal: K, inner clearance and bearing accuracy are specially controlled) tainless steel bearing Plated bearing (for corrosionresistance) Item Grease Fitting Thread ore dia. Grease Fitting Thread ore Position Table. Housing special code Housing special code Details PT tube thread PF tube thread PT tube thread 4 PF tube thread NPT tube thread Right Left 4º º oth right and left Machining E Machined for stamped cover E Cast iron cover mounting groove (diameter series, X, ) E4 Non-lubricating type Housing material H tainless steel cast steel model (C) H4 Ductile iron (FCD4-) H Rolled steel for general purpose (4) H tainless steel cast steel model (C4) Grease Fitting urface treatment N type (.º) N C type (º) Z Nickel plated housing

65 ccuracy and Internal Clearance ccuracy of a ball bearing unit is specified in JI (ball bearings for ball bearing units) and JI (housings for ball bearing units). FYH produces products conforming to these standards.. ccuracy of earings Table. to Table.4 shows the accuracy of a ball bearings for ball bearing units. all bearings for blowers (special code:, ) are produced with greater accuracy than standard models (see Table.). Table. shows the tolerance limitations of inner rings for cylindrical bore bearings. Table. Tolerances and tolerance values of outer rings of ball bearings inserts Nominal bearing outer dia. D () Variation of tolerance of average outer dia. Dm Unit: μm Radial runout of outer ring Kea Over Incl. Max. Min. Max. 4 4 C C C C C C C φd φd φd φd φd φd φd UC UK N NC -RKP U C C C C C C C φd φd φd φd φd φd φd -F ER ERC R -F Nominal bearing bore dia. d () Table. Tolerances and tolerance values of inner rings of ball bearings for ball bearing units Variation of tolerance of average bore dia. in plane Unequal bore dia. in plane Variation of tolerance of eccentricity on eccentric surface of inner ring and eccentric locking collar Variation of tolerance of inner ring width Unit: μm Radial runout of inner ring dmp Vdsp Hs s Kia Over Incl. Max. Min. Max. Max. Min. Max. Min. Max

66 ccuracy and Internal Clearance Table. Variation of tolerances and tolerance values of tapered bore on bearing with tapered bore Table.4 Tolerances and tolerance values of inner rings of C ball bearings dmp dmp C α φ (d + dmp) α φ (d + dmp) φd C Theoretical tapered bore Tapered bore with variation of tolerance of average bore dia. in plane Unit: μm Nominal bearing bore dia. d, dmp dmp dmp Vdsp ) Over Incl. Max. Min. Max. Min. Max Nominal bearing bore dia. d () Variation of tolerance of average bore dia. in plane dmp Unequal average bore dia. in plane Vdsp Unit: μm Radial runout of inner ring Over Incl. Max. Min. Max. Max.... Kia Note ) To be applied to all the radial planes of tapered bore Remarks. pplicable range pplicable to tapered bore of inner ring of tapered bore radial bearing that standard value of taper ratio is.. mount code d: tandard diameter at theoretical large end of tapered bore tandard diameter d = d + dmp: Variation of tolerance of average bore diameter in plane at theoretical small end of tapered bore dmp: Variation of tolerance of average bore diameter in plane at theoretical large end of tapered bore Vdsp: Unequal bore diameter in plane : Nominal inner ring width α: of nominal taper angle of tapered bore α = º '.4" =. 4º =.4 4 rad 4

67 Table. Tolerance limitations for radius dimensions for the inner ring of cylindrical bore bearings r (Minimum) earing bore diameter surface (xial direction) ide of inner ring (Radial direction) : r (Min.) : r (Max.) r (Min.) r (Max.) Radial direction xial direction Remark Though accurate profile of chamfered surface is not specified, the profile on the axial plane should not exceed the virtual arc of radius r (minimum) that contacts with the side of inner ring and the bearing bore diameter surface.. ccuracy of Housings This section details the tolerance specifications of the inner diameter of the spherical bore of FYH housings. These values determine how tight or how loose the bearing fits inside the housing. Table. shows the tolerance of the diameter of the spherical bore of housings. tandard tolerance for mounted units, between the outer diameter of the bearing and the inner diameter of the housing, is a class J intermediate fit. class H tolerance allows greater clearance for applications where minor shaft alignment constantly occurs or in environments where higher temperatures can cause thermal expansion. n anti-rotation pin on the outer ring of the bearing is supplied with these units to prevent the outer ring of the bearing from spinning inside the housing. class K tolerance allows less clearance and is recoended to prevent the outer ring of the bearing from rotating inside the housing. Fig.. shows examples of housing dimensions relative to installation position with tolerance values. Table. llowance of spherical bore diameter of housings φd a Nominal dia. of spherical bore Da () Tolerance class H Variation of tolerance of spherical bore dia. Dam Tolerance class J Variation of tolerance of spherical bore dia. Dam Unit: μm Tolerance class K Variation of tolerance of spherical bore dia. Dam Over Incl. Max. Min. Max. Min. Max. Min Remark FYH selects J, H, or K depending on the applications.

68 ccuracy and Internal Clearance Fig.. Dimensions relative to installation of housings with tolerances and tolerance values (representative example) Pillow type housings Take-up type housings X H H φ N H Frame for take-up type units J J J Flange type housings J 4φ N φ X M J Cartridge type housings Y J φh 4φ N φ X M Y Table. shows ordinary dimensional tolerance of cut or cast portions not specified in this catalog. φh J Table. Ordinary dimensional tolerance not specified respectively Remark Respective tolerances and tolerance values for housings are shown in dimensional tables. Item tandard code Class Cutting JI 4 Medium Casting of cast iron JI 4 Ordinary Casting of cast steel JI 4 Ordinary

69 . Internal earing Clearance Internal bearing clearance is defined as the allowable space between the bearing balls and the raceways. The degree of internal clearance, referred to as operation clearance, greatly influences operational life of the bearing as well as characteristics of heat, noise, and vibration. If the clearance is exceptionally tight between the shaft and the inner ring of the bearing then expansion of the inner ring must be taken into consideration and the correct ball clearance should be selected. Transmission heat from the shaft is also a factor to consider when determining the correct amount of ball clearance (see Operating temperature and bearing specifications ). Table. shows the internal clearance applicable to specific operating conditions and Table. shows the available options for internal clearance. Table. Internal clearance applicable to specific operating conditions Type pplicable internal clearance earing with cylindrical bore earing with tapered bore tandard type CN C NC CN tainless steel type C Heat resistant type (suffi x code: DK) C4 C Heat resistant type (suffi x code: DK) C4 C Cold resistant type (suffi x code: DK) CN C High speed type (suffi x code: K) CN C For blower (suffi x code: ) CN C For high speed blower (suffi x code: ) C C Remark For bearings with suffi x codes, as those indicated above, the clearance is implied and not indicated in the part number. Table. vailable options for internal clearance Unit: μm Nominal bearing Internal clearance bore dia. d () C CN GN C C4 C Over Incl. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Min. Max Remarks. Radial internal clearance in this table conforms to JI (ball bearing inserts).. Increase in radial internal clearance generated by measured load conforms to the table below. maller correction of C clearance is applicable to the minimum clearance, while larger correction is applicable to the maximum clearance. Unit: μm Nominal bearing bore dia. d () Measured load Correction of clearance Over Incl. N C CN GN, C C4 C

70 Materials Materials. earing Material all bearing inserts are comprised of inner and outer rings, balls, and steel ball cages all of which are made from the highest quality of bearing steel. These bearings possess the following features. () High elastic limit to resist strong opposing force () High rolling fatigue strength to allow for heavy loads () uperior hardness (4) uperior wear resistance () uperior toughness against impact and shock loads () uperior precision of dimensional tolerances High carbon chrome bearing steel is utilized for the bearing components as specified in JI (Japanese Industrial tandards). To increase reliability and reduce contamination within the material, a vacuum degassing process is executed to reduce non-metallic elements and any oxygen in the steel. fter the bearing is assembled it is heat tempered and quenched until the hardness reaches HRC. Table. shows the chemical components of high carbon chrome bearing steel. tainless steel bearing inserts (suffix: ) utilize superior corrosion resistant JI certified stainless steel. Riveted steel ball cages are made of JI certified cold rolled steel which is shown in Table... Housing Material FYH housings are made primarily of gray cast iron, and stamped steel. Gray cast iron is the most popular choice for mounted units because of its optimal characteristics of vibration absorption, high strength, and excellent heat dissipation. Table. shows the mechanical properties of gray cast iron (FC). Nodular graphite cast iron, or ductile iron, (FCD4- of JI G ) provides a good combination of rigidity and fracture resistance, and it is suitable where heavy vibration or impact forces are present. Housings for units within the Clean eries are available in die-cast zinc alloy as well as stainless steel. Housing material for stamped steel units consists of thick gauge cold rolled sheet steel and steel strip. Table.4 to. show the mechanical properties of these housing materials. Table. Chemical components of high carbon chrome bearing steel (JI G 4) Code UJ UJ Chemical components (%) C i Mn P Cr Mo or less or less or less or less or less. Table. Chemical components of cold rolled steel and steel strip (PCC) (JI G 4) Code PCC PCD Table. Chemical components (%) C i Mn P Ni Cr. or less. or less. or less. or less Mechanical properties of gray cast iron (FC). or less.4 or less. or less.4 or less Type code FC Tensile strength N/ or more Hardness H or less

71 Table.4 Mechanical properties of cast carbon steel products (JI G ) Type code Yielding point or bearing force N/ Thickness of steel incl. Over incl. 4 Over 4 Tensile strength N/ Thickness of steel Tensile test piece Elongation % ending angle ending property Inside dia. Test piece 4 4 or more or more or more 4 Over, max. Over, 4 max. Over 4 No. No. No.4 or more or more or more º. times of thickness No. Table. Code Mechanical properties of zinc alloy die-cast (ZDC) (JI H ) (Reference) Tensile strength Impact N/ % N m/cm H ZDC 4 Table. Type code C C 4 Mechanical properties of stainless cast steel products (C, C 4) (JI G ) earing force Tensile strength Elongation Hardness Elongation Hardness N/ N/ % H or more or more 44 or more 44 or more or more or more or less or less Correspondence standards C : IO GXCrNi, TM CF- (II 4) C 4: IO GXCrNiMo, TM CF-M (II ) Table. Mechanical properties of cold rolled sheet steel and steel strip (PCC) (JI G 4) Type code Tensile strength Elongation N/ % PCC or more 4 or more PCD or more or more Table. Mechanical properties of ductile cast iron (FCD4-) (JI G ) Type code Tensile strength Elongation N/ % FCD 4 or more or more. Materials of Parts and ccessories Table. shows materials of parts and accessories of a ball bearing unit. Table. Materials of parts and accessories of ball bearing units Designations Materials Code eal (standard type) eal (heat resistant, cold resistant) linger (flinger) tainless steel slinger (flinger) teel plate cover tainless steel plate cover Cast iron cover Hexagon socket set screw tainless steel hexagon socket set screw dapter sleeve for bearing Lock nut for bearing Washer for bearing Locking collar Grease fi tting tandard code Nitrile rubber NR ilicone rubber VMQ Cold rolled steel plate and steel strip Cold rolled stainless steel plate and steel strip Cold rolled steel plate and steel strip Cold rolled stainless steel plate and steel strip Gray cast iron products Chrome molybdenum steel PCC JI G 4 U4-CP, U4-C JI G 4 PCD JI G 4 U4-CP, U4-C JI G 4 FC JI G CM4 JI G 4 tainless bar steel U4 JI G 4 Mechanical structural carbon steel Mechanical structural carbon steel Cold rolled steel plate and steel strip Mechanical structural carbon steel Copper and copper alloy rod C JI G 4 C JI G 4 PCC JI G 4 C JI G 4 UM4L JI G 44

72 Performance Performance. earing Friction Torque earing friction torque is the conglomeration of the rolling friction between the balls with the inner and outer rings, the sliding friction between the balls and the cage, the agitating resistance of lubricants, and the friction resistance of the seals. The specific amount of friction torque is influenced by the particular bearing model, dimensions, bearing load, rotating speed, and lubricating conditions. earings with triple-lip seals and open cover seals will have greater friction torque and overall greater friction resistance. Friction torque for bearings can be found by the formulas below. M = Mp + Mk (.) d Mp = l P (.) Whereas, M: Friction torque of bearing, mn m M p : Friction torque of sections changed by load, mn m M k : Friction torque of sections changed by rotating speed, mn m l: Friction coefficient (. to.) P: Load applied to bearings, N d: Nominal bearing bore dia., Note that the agitating resistance of lubricants and the friction resistance of the seals are difficult to calculate since the resistance fluctuates with speed. Fig.. shows the result of measurement of friction torque of the typical ball bearing unit.. earing Temperature Increase The increase in temperature of the bearing is represented as heat energy created from friction torque in the bearing during operation. The temperature of the bearing during operation increases in proportion to the amount of friction torque, and friction torque increases in proportion to the increase in bearing load. The increase in temperature of the bearing depends on the heating value generated by friction in the bearing and the amount of heat discharged from the bearing and housing in which it is mounted. Therefore, the temperature level of the bearing is influenced by the environmental conditions of the location in which the bearing unit is installed (quality of heat radiation environment). The operating temperature of the bearing unit increases gradually after startup of operation and reaches the maximum level after one or two hours if no abnormalities occur. Then it decreases slightly and enters a steady state (see Fig..). If the operating conditions are not changed, bearing temperature will remain virtually constant, and measurement of the temperature and assumption of the bearing status are enabled. Increase in temperature ºC Pillow type unit UCPJ Rotating speed:, min Radial load kn Radial load kn Friction torque mn á m 4 UC UC UC4 t startup,,,, Rotating speed, min Fig.. Example of measurement result of ball bearing units Operating period hr Fig.. Example of temperature measurement during operation of pillow type units Increase in temperature during operation of the bearing depends on the type of seal used in the bearing as well as friction torque. Increase in temperature of triple-lip bearings (suffix code: L) is greater than that of the standard single lip model, and that of the non-contact seal (suffix code: K, ) is lower than the standard single lip model. earings for blowers and other high-speed applications are equipped with non-contact seals, with grease or oil, for high-speed operation as well as reduction of heat, vibration, and noise.

73 4 Handling 4. Installation Table 4. et screws of ball bearings for units 4.. Installation of setscrew units When installing setscrew units, it is important to tighten the setscrews to the shaft with the specified torque. When the clearance between the inner ring and the shaft is small, then grind the surface of the shaft where the setscrew contacts and make a flat base (Fig. 4.). It helps you to take the shaft out of the inner ring. Fig. 4. Flat seat provided for shaft If the unit is exposed to great load or excessive vibration, another option is to use a shouldered shaft and tighten the inner ring of the bearing with a shaft nut. (Fig. 4.) For dimensions of the shouldered shaft, see Design of shaft and base. houldered shaft haft nut Fig. 4. Example of installation with a shouldered shaft and shaft nut FYH earings are available with a variety of set screw options including Double Point and ullet Point set screws which provide a secure fit to the shaft. dditional styles of setscrews are also available to meet a range of purposes and operating conditions (see Table 4.). Designations (code) ullet Point ULLET POINT Double Point (G) Cone Point (G4) Capped Full Dog Point (G) Details The tip of the FYH ullet Point setscrew has a ball shape, and it is designed to fi rmly grip the shaft by expanding its threads outward against the threads of the inner ring of the bearing as it is tightened. When shock or vibration are problems, the ullet Point setscrew can remain affi xed to the shaft longer than other set screw styles including double point, ball point, or others. The cone point at the center of the screw, combined with the round point at the outer edge, provide excellent shaft contact and greatly reduced fi tting error. This style is also available with a nylon fi lm fused to the thread surface to prevent the screw from loosening during operation. The cone point setscrew has a º angle and fi ts a drilled cone seat in the shaft. It allows correct positioning on the shaft and prevents shaft movement in an axial direction. (Fig4.) The capped full dog point setscrew fi ts into the keyed groove in the shaft and allows for expansion and contraction of the shaft. It tightens to the inner ring of the bearing (not the shaft) to allow the shaft to fl oat within the bore of the bearing. When correct positioning is required, make a drilled cone base on the shaft, and tighten the shaft, using a cone point set screw (Fig. 4.). Fig. 4. Drilled seat provided for shaft

74 4 Handling Contact FYH for additional set screw styles. hown below are installation procedures for bearing units with setscrews. () Inspect the unit to ensure that the rigidity of the base, flatness of the mounting surface, and tolerance of the shaft meet the required standards. Check the shaft for bends, burrs, and other flaws. () Make sure that the set screws are retracted far enough so that they do not contact the shaft as the bearing is installed. () Fit the bearing unit onto the shaft and slide it to the specified position. In order to secure a tight fit, press-fit the bearing unit to the shaft with a press, cold-fit by cooling the shaft, or shrink-fit the bearing unit by warming it with an air bath ( ºC or less). void striking the bearing with a haer to press-fit the bearing to the shaft. If you give a strong impact to the side surface of the inner ring, the both slinger moves, and it may cause a problem. (4) lign the bearing unit to the specified position on the base and affix it with washers and bolts. (Fig. 4.4). Use a torque wrench to tighten the bolts to the housing to the specified torque setting. For mounting bolt torque specifications, see ppendix table in the back of the catalog. () Finally, turn the shaft by hand and make sure that it rotates without any problems. 4.. Installation of adapter style units dapter units, comprised of an adapter sleeve, locknut, and washer, can be installed into environments where they are exposed to excessive vibration and impact. It is of great importance that these units are properly mounted. If the locknut is not properly tightened, the sleeve may be loose which could lead to slippage and wear on the shaft or bearing. Conversely, if the locknut is over-tightened, the inner ring of the bearing can expand and reduce internal ball clearance which could cause excessive heat and premature failure. Installation procedures for adapter style bearings are shown below. () Inspect the unit to ensure that the rigidity of the base, flatness of the mounting surface, and tolerance of the shaft meet the required standards. Check the shaft for bends, burrs, and other flaws. () lide the adapter sleeve onto the shaft where the bearing unit will be installed. If the sleeve is too tight, place a screwdriver in the slotted portion of the sleeve and expand the slot to open the sleeve. () lide the bearing unit over the shaft and onto the adapter sleeve, then place a cylindrical reinforcing ring against the inner ring of the front side of the bearing. eat the adapter sleeve by lightly tapping all around the backside of the sleeve (Fig. 4.). Reinforcing plate Fig. 4.4 Installation of setscrew units () Tighten both of the setscrews on the inner ring to the specified torque setting (Fig. 4.). For setscrew torque specifications, see ppendix table in the back of the catalog. Fig. 4. Fitting adapter sleeve to bearing with tapered bore (4) ttach the lock washer so that the tab fits into the slot in the sleeve, and, making sure the tapered side is facing the bearing, tighten the locknut on the sleeve by hand. () lign the bearing unit to the specified position on the base and affix it with washers, and bolts. Use a torque wrench to tighten the bolts to the housing to the specified torque setting. For mounting bolt torque specifications, see ppendix table in the back of the catalog. () Use a torque wrench to tighten the locknut to the correct specification (Fig. 4.). For locknut torque specifications, see ppendix table 4 in the back of the catalog. Fig. 4. Tightening of set screws () Turn the shaft by hand and tighten the setscrews of all other bearings on the same shaft to the specified torque setting.

75 ince the rotating force of the shaft increases the tightening force of the eccentric ring to the shaft, the unit with eccentric locking collar allows secure fixing of the bearing (Fig. 4.). Fig. 4. Tightening locknut () For pillow block housings, loosen the mounting bolts and adjust the unit axially while rotating the shaft by hand. Then re-tighten the mounting bolts to the correct specification. () For flange block housings, the position of the unit must be in the correct axial position in relation to the shaft, so take extra care to properly align them before completing installation. () end one of the tabs on the washer so that it fits into one of the slots on the locknut (Fig. 4.). Fig. 4. all bearing units with eccentric locking collar Installation procedures for eccentric locking collar style bearings are shown below. () Inspect the unit to ensure that the rigidity of the base, flatness of the mounting surface, and tolerance of the shaft meet the required standards. Check the shaft for bends, burrs, and other flaws. () lide the bearing unit onto the shaft, and place it at the specified mounting position. () lign the bearing unit to the specified position on the base and affix it with washers, and bolts. (Fig. 4.4). Use a torque wrench to tighten the bolts to the housing to the specified torque setting. For mounting bolt torque specifications, see ppendix table in the back of this catalog. (4) Fit the eccentric section of the inner ring of the bearing to the eccentric recessed section of the eccentric locking collar, and rotate the collar in the direction of shaft rotation. Then, tighten the setscrew on the eccentric locking collar to the specified torque setting (Fig. 4.). Fig. 4. ending claw of washer (Locking locknut) () Finally, turn the shaft by hand and make sure that it rotates without any problems. 4.. Installation of units with eccentric locking collars Eccentric locking collar bearings provide another option for shaft locking. ince the rotating force of the shaft increases the tightening force of the eccentric ring to the shaft, this style of bearing allows a secure grip to the shaft. Fig. 4. Installing eccentric locking collar

76 4 Handling (4) The NU-LOC collar is tightened by a hexagon head bolt to a specified torque setting in order to apply the correct amount of force to the inner ring o the bearing. (Fig. 4.) Regarding tightening torque for set screws or hexagon head bolts, see ppendix Table in the back of this catalog. Pack grease Fig 4. Installation of NU-LOC units () Rotate the shaft by hand and then install the next eccentric locking collar unit to the shaft. () Finally, turn the shaft by hand and make sure that it rotates without any problems Installing units with covers Covers for ball bearing units are available in two types, steel plate and cast iron. Install both the covers at last after installation of the bearing and housing is complete. Procedures for installation of the ball bearing units with covers are shown below. () pply grease all around the seal lip of the cover, and pack the internal space of the cover with grease (approximately / to of the space capacity) (Fig. 4.). Fig. 4. Packing grease in internal space of seal lip of covers () Make sure that the bearing unit is securely fixed to the shaft and mounting base. () lide the cover over the shaft to the grove in the housing and lightly press it into place. (4) For stamped steel covers, use a plastic mallet to prevent deformation, and evenly tap all around the periphery of the cover to install it to the housing (Fig. 4.). To remove the stamped steel cover, put a screwdriver into the groove on the periphery of the cover and slightly pry it. Fig. 4. Installing steel plate covers 4

77 (4) When installing a cast iron cover, fit the cover to the cover groove of the housing, and affix it with the supplied bolts. For the tightening torque of the cast iron cover mounting bolts, see the ppendix table at the end of this catalog. () Install another cover to the housing in a similar manner. () Check for abnormality of the installed cover. () Finally, turn the shaft by hand, and check for abnormality in the bearing. 4. Test Run Inspection fter installation of the ball bearing unit is complete, execute the test run inspection to ensure that it was done properly. The test run inspection should be executed by following the procedures below. () Turn the shaft by hand and make sure that the bearing rotates smoothly. If there is any resistance, vibration, excessive rotational torque, or uneven rotation, the bearing is judged to be faulty. () Execute a powered run with no load and at low speed, and check for abnormal noise and vibration. () Execute a powered run under normal operating conditions and check for abnormal noise, vibration, and temperature increase. Table 4. shows the main faults that may occur during the test run inspection of the ball bearing unit and causes. Table 4. Main causes of bearing failure during test runs and their causes Faults Excessive torque, uneven rotating torque bnormal noise, abnormal vibration bnormal temperature increase Causes () Faulty installation, causes preload on bearing () Inappropriate handling or installation, leading to interference of seal with slinger () Excessive tightening of locknut (adapter) causing too small internal clearance of bearing () Improper tightening of set screws or of mounting bolts () Excessively large internal clearance of bearings () ent shaft, or shouldered shaft may be machined eccentrically (4) haft tolerance chosen improperly () Mounting base not rigid or flat () Too small internal clearance of bearing () Faulty installation, causes preload on bearing () Load too great (4) llowable rotational speed exceeded () Mounting base not rigid or flat () Inappropriate handling or installation, leading to interference of seal with slinger 4. Periodic Inspection FYH all earing Units do not need to be inspected as frequently as lower quality bearings. However, it is good practice to set up an inspection schedule for even these high quality bearings. ince a ball bearing unit cannot be disassembled for inspection of the internal status of components, the external appearance of the bearing must be inspected to give tell-tale signs of the status and expected life of the bearing. The following characteristics must be checked per the inspection schedule that is established for a particular application. () Overall appearance () Loose set screws or mounting bolts () Noise from vibration (4) Temperature of the bearing housing or the inner ring () Grease supply interval and quantity of grease injected into the bearing (either too much or too little grease can be detrimental to the life of the bearing) Table 4. shows the main faults that are usually found during periodic inspections and their causes. If any fault is found in a ball bearing unit during an inspection, then iediate action must be taken to correct the situation and prevent deterioration of the bearing components. If serious damage has already occurred to the bearing unit, then the bearing unit must be replaced iediately to prevent damage to other machine components. Table 4. Faults Excessive torque bnormal noise, abnormal vibration bnormal temperature increase Main faults found during periodic inspection and their causes Causes () Degraded grease () Interference of seal with slinger due to excessive supply of grease () Deformation of slinger causing interference with seal (4) High load due to shaft expansion () Improper tightening of set screws locknut (adapter) or of mounting bolts () Wear on inner ring of bearing or shaft due to creep or fretting () Ingress of foreign matter (dirt) into bearing (4) Damage to cage or ball surfaces due to rolling fatigue () Indentation on raceway surface or ball surface due to excessive load () Warped or bent shaft () Degraded grease () Interference of seal with slinger due to excessive supply of grease () Deformation of slinger causing interference with seal (4) Looseness of setscrew, eccentric locking collar or adapter lock nut for tapered bore bearings () Load due to shaft expansion () Damage to cage or ball surfaces due to rolling fatigue

78 4 Handling 4.4 upply of Grease FYH all earing units are supplied with high quality FYH Lithium earing grease and seals. Therefore, under clean operating conditions, light loads, low speeds, and low temperatures the bearing may be used with no further lubrication. However, under harsher operating conditions and environments, the grease will deteriorate much more rapidly. This would include environments exposed to dust, moisture, or higher operating temperatures. In such cases, a re-greasing schedule must be established to prevent premature failure of the bearing. The life of the bearing can be greatly extended by proper attention to the re-greasing schedule and by supplying the proper amount of grease. Please note that too much grease can be detrimental as well as too little grease Grease life and supply intervals The grease life of a bearing unit can be found using Formula (4.) in page. The re-greasing schedule should be set at to / of the grease life found by the calculation shown above; however this may be adjusted for particularly demanding environments or conditions. In addition, some environments may be unusually dirty or wet, and these conditions may be exacerbated by higher temperatures. Under such harsh conditions, a more frequent re-greasing schedule will extend the life of the bearing. Under normal operating conditions, adhere to the guidelines outlined in Table. in page mount of grease The amount of grease initially supplied in a new FYH all earing Unit is approximately to % of the internal space capacity of the bearing. If the bearing is over greased, the agitation of the grease causes internal friction and heating of the bearing. The first sign of failure will be excessive grease finding its way to the outside of the bearing. DO NOT exceed the initial greasing amount. Table 4.4 shows the recoended amount of grease to be used for re-greasing FYH bearings. In a severely dusty or wet environments, the amount of grease may be as much as doubled if operating speeds are low. Table 4.4 mount of recoended grease for ball bearing units ore dia. code... Greasing amount, g Diameter eries ) UC UCX UC The basic bearing size number consists of the duty code (, X, or ) followed by the inner ring size code (,, 4, etc.) Note:. Table 4.4 applies to UK units as well.. For greasing triple-lip (L) type bearings, use times the amount of grease recoended in the table.. Values shown in the table are applicable to standard grease (density:. g/ml). If a compatible grease of another specific gravity is used, then the proper conversion must be made to insure that the recoended volume is put into the bearing.

79 4.4. Types of grease supplied Many different types of grease are available for use in ball bearings. However, if a non-compatible grease is used, particularly a non-lithium based grease, then performance may be drastically reduced. Only use the grease recoended in Table. (page ) to assure optimum performance of your bearings. If another grease is used in an emergency situation, for instance, please assure that this grease is compatible, with a lithium base, at the minimum. If it is difficult to access the standard straight type grease fitting with a grease gun,.º and º angled fittings are available as an option. ee the images below of these grease fittings. Contact FYH for more information. Type Type (.º) Type C (º) Relubricating the unit at the specified interval Note Fig. 4.4 which shows the grease fitting, grease groove and grease holes for relubrication of the unit. upplying grease Fig. 4. Types of grease fittings for ball bearing units When using a centralized automatic lubrication system, with ball bearings, it is important to use softer grease than normal. The grease should be specified with a worked penetration number between and. This is NLGI grade or. Piping from the lubricating system must be sized so that the specified volume of grease is supplied. Piping must be connected to the threaded hole on the ball bearing unit. This is either - tapered threads for units up to and including ring size, or PT (PT) for ball bearing units with a ring size and larger. If the piping size used is larger than the threaded hole in the ball bearing unit, then the appropriate reducing coupling (or street elbow) must be used to fit the threaded hole. Fig. 4. shows the body of a pipe reducer. When using an automatic centralized lubrication system, it is imperative to assure that the correct volume of grease is supplied to each individual bearing as specified in Table 4.4. The total amount of grease is a multiple of the number of bearings being supplied by the central lubrication system. Fig. 4.4 upplying grease to ball bearing units () Clean the grease fitting and the area around it to prevent dirt and foreign material from entering the unit. () Clean the grease gun and pack clean grease. () Grease the unit with the recoended amount of grease. When lubricating the ball bearing unit, slowly turn the shaft with your hand. This allows the fresh grease to be uniformly distributed inside the unit. Fig. 4. Reducing coupling for centralized lubrication systems

80 4 Handling 4. Replacing earings If a bearing insert needs to be replaced, it is not always necessary to replace the housing if the housing is intact. fter carefully inspecting the housing to ensure that it is not damaged, simply insert a new bearing into the old housing. Replacement procedures for a bearing insert are listed below. () Remove the complete bearing unit from the shaft and mounting base. () crew in the set screws so that the head of each set screw does not protrude outside the outer diameter of the inner ring. Otherwise, the head of the set screw may damage the bearing seat inside the housing. () Use a bar or pipe to rotate the bearing º until the bearing is horizontal. (4) Remove the bearing insert from the housing via the loading slot in the back of the housing. Reverse the above procedure to put in a new bearing insert. Ensure that the set screws are screwed in before proceeding with the replacement.

81 Dimensional Tables for all earing Units

82 Dimensional Tables for all earing Units (contents) Pillow lock Units Pillow lock Units UCP (d ~ 4)... NP (d ~ )... NP-E (d / ~ /)... NPK (d ~ )... NCP (d ~ )... 4 UKP (d ~ )... Thick Pillow lock Units UCIP (d 4 ~ 4)... UKIP (d ~ )... 4 Tapped-ase Pillow lock Units UCP (d ~ )... UCPN (d ~ )... NCP (d ~ )... NCPN (d ~ )... High-ase Pillow lock Units UCPH (d ~ )... 4 Narrow Inner Ring earing Pillow lock Units P-RKP (d ~ 4)... P-FP (d ~ )... PN-RKP (d ~ )... PN-FP (d ~ )... Light Pillow lock Units LP (d ~ 4)... LP (d ~ 4)... Compact Pillow lock Units UP (d ~ )... Corrosion Resistant eries Pillow lock Units UCP-H (d ~ )... 4 UCP-H (d ~ 4)... UP- (d ~ )... UCVP- (d ~ )... UCVP-E (d ~ )... UCVPN-E (d ~ )... 4 tamped teel Pillow lock Units PP (d ~ )... PP (d ~ )... 4-olt Flange Units 4-olt Flange Units UCF (d ~ 4)... UCF-E (d ~ ) NNF (d ~ )... 4 NCF (d ~ )... NCF-E (d ~ )... UKF (d ~ )... 4 quare Piloted 4-olt Flange Units UCF (d ~ 4)... UKF (d ~ )... Narrow Inner Ring earing 4-olt Flange Units F-RKP (d ~ 4)... 4 F-FP (d ~ )... 4 Corrosion Resistant eries 4-olt Flange Units UCF-H (d ~ )... UCF-EH (d ~ )... UCVF- (d ~ 4)... UCVF-E (d ~ 4)... Oval Flange Units -olt Flange Units UCFL (d ~ )... 4 UCFL-E (d ~ )... NNFL (d ~ )... 4 NCFL (d ~ )... NCFL-E (d ~ )... UKFL (d ~ )... djustable -olt Flange Units UCF (d ~ ) olt Flange Units UCF (d ~ )... Narrow Inner Ring earing -olt Flange Units FL-RKP (d ~ 4)... FL-FP (d ~ )... Light -olt Flange Units TFD-H4RKP (d ~ )... TFD-FH4P (d ~ )... Light -olt Flange Units LF (d ~ )... LF (d ~ )... Compact -olt Flange Units UFL (d ~ )... 4 Corrosion Resistant eries -olt Flange Units UCFL-H (d ~ )... UCFL-EH (d ~ )... UFL- (d ~ )... UCVFL- (d ~ 4)... UCVFL-E (d ~ 4)... 4 Corrosion Resistant eries -olt Flange Units UCVF-E (d ~ )...

83 4 4-olt Flange Cartridge Units 4-olt Flange Cartridge Units UCFC (d ~ )... UCFCX-E (d ~ )... UCFCF (d ~ )... 4 NCFC (d ~ )... UKFC (d ~ )... Narrow Inner Ring earing 4-olt Flange Cartridge Units FC-RKP (d ~ 4)... FC-FP (d ~ )... Corrosion Resistant eries 4-olt Flange Cartridge Units UCFC-H (d ~ 4)... 4 tamped teel Flange Units tamped teel -olt Flange Cartridge Units PF (d ~ )... PF (d ~ )... tamped teel -olt Flange Units PFL (d ~ )... PFL (d ~ )... Take-Up Units Take-Up Units UCT (d ~ 4)... 4 UCT-E (d ~ )... 4 NT-E (d ~ )... NCT (d ~ )... NCT-E (d ~ )... 4 UKT (d ~ )... Narrow lot Take-Up Units UCTR (d ~ )... Corrosion Resistant eries Take-Up Units UCT-H (d ~ )... UCT-EH (d ~ )... 4 ection teel Frame Take-Up Units UCTH (d ~ )... Channel teel Frame Take-Up Units UCTL (d ~ 4)... UCTU (d 4 ~ )... teel Plate Frame Take-Up Units PTH (d ~ )... 4 NPTH (d ~ )... Other Units Cartridge Units UCC (d ~ 4)... UKC (d ~ )... Hanger Units UCH (d ~ )... 4 all earing Inserts Cylindrical bore (with set screws) UC,, -RKP, U (d ~ 4)... tainless steel series Cylindrical bore (with set screws) UC-, U- (d ~ )... 4 Cylindrical bore (with eccentric locking collar), -F, N (d ~ )... Cylindrical bore (with concentric locking collar) NC (d ~ )... Cylindrical bore (with concentric locking collar) Cylindrical O. D. ERC (d ~ )... 4 Tapered bore (with adapter) UK (d ~ )... Cylindrical bore (with set screws) Cylindrical O. D. ER, R (d ~ )... Cylindrical bore (with set screws) Cylindrical O. D. -RK (d ~ )... 4 Cylindrical bore (with eccentric locking collar) Cylindrical O. D. -FP (d ~ )... 4 Cylindrical bore C (d ~ 4)... earing dapter HX (d ~ )...

84 Pillow lock Units UCP Cylindrical bore (with set screws) d ~ (4) N N UCP UCPX, With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs P~P PX~PX P~P ±. P~P PX~PX P~P ±. PX P~P ±. Forms and dimensions of Hc of P4JE and PJE (housing with cast iron cover) are shown below. H P4JE Hc = PJE Hc = H H c H L J L haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn inch inch inch Open Type One ide Open Type One ide d H L J N N H H L kg Cr Cr f Closed Type s kg Closed Type c kg 4 4 /. / / / / / / / /. / / / 4. /. / 4 / /. 4 / / / / / 4 / / / / / / / / / / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ / 4 / 4 / M M M M4 M4 M4 M4 M4 M4 M4 M4 M4 M M4 M4 M UCP UCP- UCP UCP- UCP UCP4- UCP4 UCP-4 UCP- UCP UCP- UCPX UCPX- UCP UCP- UCP- UCP UCP- UCP- UCPX UCPX- UCPX- P P4 P PX P P PX UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UCX UCX- UC UC- UC- UC UC- UC- UCX UCX- UCX UCPC UCPC UCPC UCP4C UCPC UCPXC UCPC UCPXC UCPCD UCPCD UCPCD UCP4CD UCPCD UCPXCD UCPCD UCPXCD / UCP4FC UCPFC UCPC UCPFC UCP4FCD UCPFCD UCPCD UCPFCD UCP P UC.... UCPC UCPCD. UCP- UCP- UCP- UCP UCP- UCPX- UCPX UCPX- P PX UC- UC- UC- UC UC- UCX- UCX UCX UCPC UCPXC UCPCD UCPXCD.. UCPFC UCPFCD UCP P UC..4.. UCPC UCPCD. UCP-4 UCP- UCP UCPX-4 UCPX UCP-4 UCP UCP- UCP- UCP- UCP UCPX- UCPX- UCPX P PX P P PX UC-4 UC- UC UCX-4 UCX UC-4 UC UC- UC- UC- UC UCX- UCX- UCX UCPC UCPXC UCPC UCPXC UCPCD UCPXCD UCPCD UCPXCD UCPFC UCPC UCPFC UCPFCD UCPCD UCPFCD. s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UCPJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Representative examples of the forms of housing are indicated.. Housings of nodular graphite cast iron are also available. / /

85 Pillow lock Units UCP Cylindrical bore (with set screws) d (4) ~ () N N UCP UCPX, With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs P~P PX~PX P~P ±. P~P PX~PX P~P ±. PX P~P ±. Forms and dimensions of Hc of P4JE and PJE (housing with cast iron cover) are shown below. H P4JE Hc = PJE Hc = H H c H L J L haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn inch inch inch Open Type One ide Open Type One ide d H L J N N H H L kg Cr Cr f Closed Type s kg Closed Type c kg /. / / / / / / / / / / 4 / 4 4 / / / / / / / / 4 / / 4 / / 4 / / / / 4 / / / / 4 / 4 / 4 4 / / / / / / / 4 / / 4 / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ / M M M M M M M M M M M M M M M M M M UCP- UCP UCP- UCP- UCP UCP- UCPX- UCPX UCPX- P P PX UC- UC UC- UC- UC UC- UCX- UCX UCX UCPC UCPXC UCPCD UCPXCD UCPC UCPFC UCPCD UCPFCD UCP P UC.... UCPC UCPCD 4. UCP- UCP-4 UCP UCP- UCPX UCPX- UCPX- UCP- UCP UCP- UCP- UCP UCP- UCP- UCPX UCPX- UCP UCP- UCP-4 UCP UCPX-4 UCPX UCP-4 UCP UCP4-44 UCP4 UCPX4-44 UCPX4 UCP4-44 UCP4 UCP-4 UCP UCP-4 UCPX-4 UCPX UCPX-4 P PX P P PX P P PX P P4 PX4 P4 P PX UC- UC-4 UC UC- UCX UCX- UCX- UC- UC UC- UC- UC UC- UC- UCX UCX- UC UC- UC-4 UC UCX-4 UCX UC-4 UC UC4-44 UC4 UCX4-44 UCX4 UC4-44 UC4 UC-4 UC UC-4 UCX-4 UCX UCX UCPC UCPXC UCPC UCPXC UCPC UCPXC UCP4C UCPX4C UCPC UCPXC UCPCD UCPXCD UCPCD UCPXCD UCPCD UCPXCD UCP4CD UCPX4CD UCPCD UCPXCD UCPFC UCPC UCPFC UCPC UCPFC UCPC UCP4FC UCP4C UCPFC UCPFCD UCPCD UCPFCD UCPCD UCPFCD UCPCD UCP4FCD UCP4CD UCPFCD. s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UCPJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Representative examples of the forms of housing are indicated.. Housings of nodular graphite cast iron are also available / /

86 Pillow lock Units UCP Cylindrical bore (with set screws) d () ~ 4 N N UCP UCPX, With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs P~P PX~PX P~P ±. P~P PX~PX P~P ±. PX P~P ±. Forms and dimensions of Hc of P4JE and PJE (housing with cast iron cover) are shown below. H P4JE Hc = PJE Hc = H H c H L J L haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn inch inch inch Open Type One ide Open Type One ide d H L J N N H H L kg Cr Cr f Closed Type s kg Closed Type c kg / / / / 4 / / / 4 / / / 4 / 4 / / / / / / / / / / / / 4 / 4 / 4 / 4 / 4 / 4 4 / 4 4 / / 4 4 / 4 / / 4 / 4 4 / 4 / 4 4 / / / 4 4 / 4 / 4 / 4 / 4 4 / / / M M M M M M M M M M M M M M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ UCP-4 UCP UCP-4 UCP- UCP P P UC-4 UC UC-4 UC- UC UCPC UCPCD 4. UCPC UCPFC UCPCD UCPFCD UCPX PX UCX UCPXC UCPXCD 4 /. UCP P UC... UCPC UCPCD /.4 UCP- UCP UCPX UCPX- P PX UC- UC UCX UCX UCPC UCPXC UCPCD UCPXCD 4 / 4.. UCPFC UCPFCD UCP P UC... UCPC UCPCD 4. UCP- UCP P UC- UC UCPC UCPCD 4. UCPFC UCPFCD UCPX PX UCX UCPXC UCPXC. UCP- UCP P UC- UC.. 4. UCPC UCPCD UCP P UC.. UCPC UCPCD. UCPX UCPX- UCPX-4 UCP UCP- UCP-4 PX P UCX UCX- UCX-4 UC UC- UC UCPXC UCPC UCPXCD UCPCD UCP P UC. 4. UCPC UCPCD 4. UCP P UC 44.. UCPC UCPCD. UCP4 P4 UC4.4. UCP4C UCP4CD 4. UCP P UC. 4. UCPC UCPCD 4 / 4. UCP P UC. 4. UCPC UCPCD. s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UCPJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Representative examples of the forms of housing are indicated.. Housings of nodular graphite cast iron are also available / /

87 Pillow lock Units NP Cylindrical bore (with eccentric locking collar) d ~ Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs P~P ±. P~P ±. N H N H H L J L haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J N N H H L Cr Cr f kg 4 4 /. / / / / / / / / / /. /. / / /. 4 / 4 4 / / / / / / / / / / / / / / 4 4 / 4 / 4 / / 4 4 / / / / Remarks. In Part No. of unit, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... ~ M M M M4 M4 M4 M4 M M M M M M NP NP- NP NP- NP NP4- NP4 NP-4 NP- NP NP- NP- NP NP- NP- NP- NP- NP- NP NP- NP-4 NP- NP NP- NP- NP- NP NP- NP- NP NP- NP- NP-4 NP NP- NP- NP NP- NP- NP-4 NP NP4-44 NP4 NP-4 NP P P4 P P P P P P P P P P4 P N N- N N- N N4- N4 N-4 N- N N- N- N N- N- N- N- N- N N- N-4 N- N N- N- N- N N- N- N N- N- N-4 N N- N- N N- N- N-4 N N4-44 N4 N-4 N s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : NPJL, NL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Representative examples of the forms of housing are indicated.. Housings of nodular graphite cast iron are also available.

88 Pillow lock Units NP-E Cylindrical bore (with eccentric locking collar) d / ~ / inch N Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs PE~PE ±. PE~PE ±. H N H H L J L haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J N N H H L Cr Cr f kg / / / / / / / / /.4 /. / 4. / / 4 / 4 / / 4 / / / / / / / 4 44 / 4.. /. / /. / /. / / / / 4 / Remarks. In Part No. of unit, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... ~ M4 M4 M4 M M M M M M NP-E PE N-.... NP-E PE N NP-4E PE N NP-E PE N NP-E PE N-... NP-E PE N NP-E PE N-.... NP4-4E P4E N NP-4E PE N s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : NPJEL, NL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Representative examples of the forms of housing are indicated.. Housings of nodular graphite cast iron are also available.

89 Pillow lock Units NPK Cylindrical bore (with eccentric locking collar) d ~ N Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs PK4~PK ±. PK~PK ±. N H H H L J L haft Dia Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J N N H H L Cr Cr f kg 4 4 / / / / / / / / /. /. /. / 4 / 4. /.4 /. /. /. / / 4. 4 / / / / / 4 / 4 / 4 / 4 / 4 / 4 / 4.. / 4 / 4 Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -Rc... ~ / 4 / / 4 / / / / NPK NPK- NPK NPK- NPK NPK4- NPK4 NPK-4 NPK- NPK NPK- NPK- NPK NPK- NPK- NPK- NPK- NPK- NPK NPK- NPK-4 NPK- NPK NPK- NPK- NPK- NPK NPK- NPK- NPK NPK- NPK- NPK-4 NPK NPK- NPK- NPK NPK- NPK- NPK-4 NPK PK4 PK PK PK PK PK PK PK PK PK N N- N N- N N4- N4 N-4 N- N N- N- N N- N- N- N- N- N N- N-4 N- N N- N- N- N N- N- N N- N- N-4 N N- N- N N- N- N-4 N For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated.. Housings of nodular graphite cast iron are also available.

90 Pillow lock Units NCP Cylindrical bore (with concentric locking collar) d ~ N Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs P4~P ±. P~P ±. N H H H L J L haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J N N H H L d Cr Cr f kg 4 4 / / /. /. / / 4. / 4. 4 / 4 /.. /.. /. 4 / / / / / / / / / / / 4 4 / 4 / 4 / 4 4 / / / /. /. / Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R... ~ / 4. /. /. /. /. /.4 / / M M M4 M4 M4 M4 M4 M4 M M M M M NCP4- NCP4 NCP-4 NCP- NCP NCP- NCP- NCP NCP- NCP- P4 P P NC4- NC4 NC-4 NC- NC NC- NC- NC NC- NC NCP- P NC NCP- NCP NCP- NCP-4 NCP P P NC- NC NC- NC-4 NC NCP- P NC NCP- NCP- NCP NCP- NCP NCP- P P NC- NC- NC NC- NC NC NCP- P NC NCP NCP- P NC NC NCP- P NC NCP NCP- P NC NC For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated. 4

91 Pillow lock Units UKP Tapered bore (with adapter) d ~ () N N UKP UKPX, With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs P~P PX~PX P~P ±. P~P PX~PX P~P ±. PX P~P ±. Forms and dimensions of Hc of PJE (housing with cast iron cover) are shown below. H PJE Hc = H H c H L J L haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn inch inch inch Open Type One ide Open Type One ide d H L J N N H H L kg Cr Cr f Closed Type s kg Closed Type c kg 4 4 / / / 4. /. 4 / / / / 4 4 / / / / 4 4 / / / / / / / / / / / / / / 4 / / 4 / 4 / / / / / 4 / 4 / 4 / 4 / 4 / 4 Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ / 4 4 / / / M M4 M4 M4 M4 M4 M4 M4 M4 M4 M M4 M4 M M M M M M M UKP P UK UKPX PX UKX UKP P UK UKP P UK UKPX PX UKX UKP P UK UKP P UK UKPX PX UKX UKP P UK UKP P UK UKPX PX UKX UKP P UK UKP P UK UKPX PX UKX UKP P UK UKP P UK UKPX PX UKX UKP P UK UKP P UK UKPX PX UKX HEX HX HEX HX HEX HX HX HEX HX HEX HX HEX HX HX HX HX HX HX HEX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HEX HX HEX HX HEX HX HEX HX HX HX HEX HX HX HEX UKPC UKPXC UKPC UKPXC UKPC UKPXC UKPC UKPXC UKPC UKPXC UKPC UKPXC UKPC UKPXC UKPCD UKPXCD UKPCD UKPXCD UKPCD UKPXCD UKPCD UKPXCD UKPCD UKPXCD UKPCD UKPXCD UKPCD UKPXCD / UKPFC UKPC UKPFC UKPC UKPFC UKPC UKPFC UKPC UKPFC UKPC UKPFC UKPC UKPFC UKPFCD UKPCD UKPFCD UKPCD UKPFCD UKPCD UKPFCD UKPCD UKPFCD UKPCD UKPFCD UKPCD UKPFCD. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKPJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (or L) follows the Part No. of unit or bearing.. For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Representative examples of the forms of housing are indicated.. Housings of nodular graphite cast iron are also available. / 4 /

92 Pillow lock Units UKP Tapered bore (with adapter) d () ~ () N N UKP UKPX, With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs P~P PX~PX P~P ±. P~P PX~PX P~P ±. PX P~P ±. Forms and dimensions of Hc of PJE (housing with cast iron cover) are shown below. H PJE Hc = H H c H L J L haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn inch inch inch Open Type One ide Open Type One ide d H L J N N H H L kg Cr Cr f Closed Type s kg Closed Type c kg / / 4 / / / / / 4 / 4 / / / / / / / / / / / / 4 / / 4 / / 4 / 4 4 / 4 4 / / / / 4 4 / 4 / / 4 / 4 4 / / / 4 / / / 4 / 4 4 / 4 / 4 / 4 / 4 4 / / / / / / / / / / / / M M M M M M M M M M M M M M M M M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ UKP P UK UKP P UK UKPX PX UKX UKP P UK UKP P UK UKPX PX UKX UKP P UK UKP P UK UKPX PX UKX UKP P UK UKP P UK UKPX PX UKX UKP P UK UKP P UK UKPX PX UKX UKP P UK HX HX HEX HX HX HX HX HX HX HEX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HEX HX HEX HX HEX HX HEX HX HX HEX HX HEX HX HEX UKPC UKPXC UKPC UKPXC UKPC UKPXC UKPC UKPXC UKPC UKPXC UKPCD UKPXCD UKPCD UKPXCD UKPCD UKPXCD UKPCD UKPXCD UKPCD UKPXCD / 4 / UKPC UKPFC UKPC UKPFC UKPC UKPFC UKPC UKPFC UKPC UKPFC UKPC UKPCD UKPFCD UKPCD UKPFCD UKPCD UKPFCD UKPCD UKPFCD UKPCD UKPFCD UKPCD UKP P UK HX UKPC UKPCD 4. UKPFC UKPFCD. UKPX PX UKX HX UKPXC UKPXCD.4 UKP P UK HX. 4. UKPC UKPCD. UKP P UK UKPX PX UKX HEX HX HEX HX UKPC UKPXC UKPCD UKPXCD. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKPJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (or L) follows the Part No. of unit or bearing.. For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Representative examples of the forms of housing are indicated.. Housings of nodular graphite cast iron are also available / 4 / / /

93 Pillow lock Units UKP Tapered bore (with adapter) d () ~ N N UKP UKPX, With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs P~P PX~PX P~P ±. P~P PX~PX P~P ±. PX P~P ±. Forms and dimensions of Hc of PJE (housing with cast iron cover) are shown below. H PJE Hc = H H c H L J L haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn inch inch inch Open Type One ide Open Type One ide d H L J N N H H L kg Cr Cr f Closed Type s kg Closed Type c kg / / / 4 / 4 / 4 / 4 / 4 / 4 / / / M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ UKP P UK UKP P UK HEX HX HX HEX UKPC UKPC UKPCD UKPCD UKP4 P4 UK4 H4.. UKP4C UKP4CD. UKP P UK HE H.. 4. UKPC UKPCD UKP P UK H. 4. UKPC UKPCD. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKPJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (or L) follows the Part No. of unit or bearing.. For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Representative examples of the forms of housing are indicated.. Housings of nodular graphite cast iron are also available. 4 4 / 4...

94 Thick Pillow lock Units UCIP Cylindrical bore (with set screws) d 4 ~ 4 With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs), variations of tolerance of distance between centers of bolt holes (Js) and variations of tolerance of bolt hole diameter (Ns) Housing No. Hs Js Ns IP~IP ±. ±. ±. IP~IP IP~IP ±. ±. IP~IP ±. ±. H H -φn H J L haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn inch inch inch Open Type One ide Open Type One ide d H L J N H H kg Cr Cr f Closed Type s kg Closed Type c kg 4 4 / / / / / 4 4 / 4 4 / 4 4 / / / 4 4 / 4 4 / 4 4 / / / / 4 4 / / / / / / 4 / / / 4 / / / M M M M M M M M M M M M M M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... ~, ~ UCIP-4 UCIP- UCIP UCIP- UCIP- UCIP- UCIP UCIP- UCIP- UCIP UCIP- UCIP- UCIP-4 UCIP UCIP- UCIP- UCIP UCIP- UCIP- UCIP-4 UCIP UCIP-4 UCIP UCIP4-44 UCIP4 UCIP-4 UCIP UCIP-4 IP IP IP IP IP IP IP IP4 IP UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC- UC- UC-4 UC UC- UC- UC UC- UC- UC-4 UC UC-4 UC UC4-44 UC4 UC-4 UC UC UCIPC UCIPC UCIPC UCIPC UCIPC UCIPC UCIPCD UCIPCD UCIPCD UCIPCD UCIPCD UCIPCD UCIPFC UCIPFC UCIPFC UCIPFC UCIPFC UCIPFC UCIPC UCIP4C UCIPC UCIPFCD UCIPFCD UCIPFCD UCIPFCD UCIPFCD UCIPFCD UCIPCD UCIP4CD UCIPCD UCIP IP UC... UCIPC UCIPCD /. UCIP IP UC... UCIPC UCIPCD 4. UCIP- UCIP IP UC- UC.. 4. UCIPC UCIPCD UCIP IP UC.. UCIPC UCIPCD. UCIP UCIP- UCIP-4 IP UC UC- UC UCIP IP UC.4. UCIPC UCIPCD. UCIP4 IP4 UC4.. UCIP4C UCIP4CD. UCIP IP UC. 4. UCIPC UCIPCD 4 /. UCIP IP UC. 4. UCIPC UCIPCD UCIPC. s for the triple seal type product, suffix code L follows the Part No. of unit or bearing. (Example of Part No. : UCIPJL, UCL) 4. s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available. UCIPCD / /

95 Thick Pillow lock Units UKIP Tapered bore (with adapter) d ~ With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs), variations of tolerance of distance between centers of bolt holes (Js) and variations of tolerance of bolt hole diameter (Ns) Housing No. Hs Js Ns IP~IP ±. ±. ±. IP~IP IP~IP ±. ±. IP~IP ±. ±. H H -φn H J L haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn inch inch inch Open Type One ide Open Type One ide d H L J N H H kg Cr Cr f Closed Type s kg Closed Type c kg / 4 / 4 / 4 4 / 4 4 / 4 4 / / / 4 4 / / / / / / 4 / / / 4 / / / 4 4 / 4 / / / / / / M M M M M M M M M M M M M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... ~, ~ UKIP IP UK UKIP IP UK UKIP IP UK UKIP IP UK UKIP IP UK UKIP IP UK UKIP IP UK UKIP IP UK UKIP IP UK UKIP IP UK HEX HX HX HEX HX HEX HX HX HX HEX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HX HEX UKIPC UKIPC UKIPC UKIPC UKIPC UKIPC UKIPCD UKIPCD UKIPCD UKIPCD UKIPCD UKIPCD UKIPFC UKIPFC UKIPFC UKIPFC UKIPFC UKIPFC UKIPC UKIPC UKIPC UKIPC UKIPFCD UKIPFCD UKIPFCD UKIPFCD UKIPFCD UKIPFCD UKIPCD UKIPCD UKIPCD UKIPCD UKIP IP UK HX. 4. UKIPC UKIPCD. UKIP IP UK UKIP IP UK UKIP IP UK HEX HX HEX HX HX HEX UKIPC UKIPC UKIPC UKIPCD UKIPCD UKIPCD UKIP4 IP4 UK4 H4.. UKIP4C UKIP4CD. UKIP IP UK HE H.. 4. UKIPC UKIPCD UKIP IP UK H. 4. UKIPC UKIPCD 4. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKIPJ + HX, UK + HX) 4. s for the triple seal type product, suffix code L follows the Part No. of unit or bearing. (Example of Part No. : UKIPJL + HX, UKL + HX). For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Housings of nodular graphite cast iron are also available / / / /

96 Tapped-ase Pillow lock Units UCP Cylindrical bore (with set screws) d ~ Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. Hs Js P4~P ±. ±. H H H L J L -N haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn d H L J N H H L Cr Cr f kg 4 4 / / / / / / / /. /. / / / 4 / / 4 / M. M. M4 M4 / 4 M4 M4 4 4 M / 4 4 / 4 / / / UCP UCP- UCP UCP- UCP UCP4- UCP4 UCP-4 UCP- UCP UCP- UCP- UCP UCP- UCP- UCP- UCP- UCP- UCP UCP- UCP-4 UCP- UCP UCP- UCP- UCP- UCP UCP- UCP- UCP UCP- P4 P P P P P UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC- Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is --UNF.. s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows Part No. of unit or bearing. (Example of Part No. : UCPJL, UCL) P s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Tapered bore (with adapter) type products are also available. (Example of Part No. : UKPJ + HX, UK + HX). Housings of nodular graphite cast iron are also available.

97 Tapped-ase Pillow lock Units UCPN Cylindrical bore (with set screws) d ~ Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. Hs Js PN4~PN ±. ±. H H H L J L -N haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn d H L J N H H L Cr Cr f kg / / / / /. /. / / UNC -UNC /-4UNC -UNC 4. / UCPN4- UCPN4 UCPN-4 UCPN- UCPN UCPN- UCPN- UCPN UCPN- UCPN- UCPN- UCPN- UCPN- UCPN UCPN- PN4 PN PN PN UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is --UNF.. s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows Part No. of unit or bearing. (Example of Part No. : UCPNJL, UCL) s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Tapered bore (with adapter) type products are also available. (Example of Part No. : UKPNJ + HX, UK + HX). Housings of nodular graphite cast iron are also available.

98 Tapped-ase Pillow lock Units NCP Cylindrical bore (with concentric locking collar) d ~ Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. Hs Js P4~P ±. ±. H H H L J L -N haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn 4 4 d H L J N H H L d Cr Cr f kg / / /. /. / / 4. / / 4. /. / 4 / / 4 4 / M. M. M4 M4 M4 / 4 M4 M4 M4 4 4 M / 4 4 / / / /. / / 4. /. /. /. /. /.4 Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is --UNF.. s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4 / 4 / / 4.. NCP4- NCP4 NCP-4 NCP- NCP NCP- NCP- NCP NCP- NCP- P4 P P NC4- NC4 NC-4 NC- NC NC- NC- NC NC- NC NCP- P NC NCP- NCP NCP- NCP-4 NCP P P NC- NC NC- NC-4 NC NCP- P NC NCP- NCP- NCP NCP- NCP NCP- P P NC- NC- NC NC- NC NC

99 Tapped-ase Pillow lock Units NCPN Cylindrical bore (with concentric locking collar) d ~ Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. Hs Js PN4~PN ±. ±. H H H L J L -N haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn d H L J N H H L d Cr Cr f kg / / /. /. / / 4. / UNC 4 -UNC /-4UNC -UNC -UNC Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is --UNF.. s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. / 4 4. /. / / 4. /. /. /. NCPN4- NCPN4 NCPN-4 NCPN- NCPN NCPN- NCPN- NCPN NCPN- NCPN- PN4 PN PN NC4- NC4 NC-4 NC- NC NC- NC- NC NC- NC NCPN- PN NC NCPN- NCPN NCPN- PN NC- NC NC-..4..

100 High-ase Pillow lock Units UCPH Cylindrical bore (with set screws) d ~ Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs PH4~PH ±. H N H N H L J L haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J N N H H L Cr Cr f kg 4 4 / / / / / / / 4 / / 4 / / / / / / 4 / M M M4 M4 M4 M4 UCPH UCPH- UCPH UCPH- UCPH UCPH4- UCPH4 UCPH-4 UCPH- UCPH UCPH- UCPH- UCPH UCPH- UCPH- UCPH- UCPH- UCPH- UCPH UCPH- UCPH-4 UCPH- UCPH UCPH- UCPH- UCPH- UCPH UCPH- UCPH- UCPH UCPH- PH4 PH PH PH PH PH UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC- Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is --UNF.. s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows Part No. of unit or bearing. (Example of Part No. : UCPHJL, UCL) /...4 M PH s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Tapered bore (with adapter) type products are also available. (Example of Part No. : UKPHJ + HX, UK + HX) 4

101 Narrow Inner Ring earing Pillow lock Units P-RKP Cylindrical bore (with set screws) d ~ P-FP Cylindrical bore (with eccentric locking collar) Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs P4~P ±. P ±. N N H N H N H H H H P-RKP P-FP P-RKP L J L P-FP L J L haft Dia. Dimensions olt Unit earing Unit earing Housing asic Factor Mass inch inch ize No. No. No. No. No. Load Ratings kn kg inch P-RKP P-FP Cr Cr f P-RKP P-FP d H L J N N H H L / /.4... P4-RKP 4-RKP P4-FP 4-FP.. P M P4RKP 4RKP P4FP 4FP.. P-4RKP -4RKP P-4FP -4FP.. / / P-RKP -RKP P-FP -FP.. P M P-RKP -RKP P-FP -FP.. PRKP RKP PFP FP / / / / / / / / / / / / / / / / 4 4 / 4 / 4 Remarks. In Part No. of unit, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R M4 M4 M4 M4 M M P-RKP P-RKP P-RKP PRKP P-RKP P-RKP P-RKP PRKP P-4RKP PRKP -RKP -RKP -RKP RKP -RKP -RKP -RKP RKP -4RKP RKP P-FP P-FP P-FP PFP P-FP P-FP P-FP P-FP PFP P-4FP P-FP PFP P-FP P-FP P-FP PFP P-FP P-FP PFP P-FP P-4FP P-FP PFP -FP -FP -FP FP -FP -FP -FP -FP FP -4FP -FP FP -FP -FP -FP FP -FP -FP FP -FP -4FP -FP FP P... P..4. P.. 4. P P P For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated.. Housings of nodular graphite cast iron are also available

102 Narrow Inner Ring earing Pillow lock Units PN-RKP Cylindrical bore (with set screws) d ~ PN-FP Cylindrical bore (with eccentric locking collar) Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. Hs Js PN4~PN ±. ±. H H H H H H PN-RKP PN-FP PN-RKP L J L -N PN-FP L J L -N haft Dia. Dimensions Unit earing Unit earing Housing asic Factor Mass inch inch No. No. No. No. No. Load Ratings kn kg PN-RKP PN-FP Cr Cr f PN-RKP PN-FP d H L J N H H L / / / / /. /. / / UNC -UNC /-4UNC -UNC 4. Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is --UNF. / PN4-RKP PN4RKP PN-4RKP PN-RKP PN-RKP PNRKP PN-RKP PN-RKP PN-RKP PNRKP PN-RKP PN-RKP PN-RKP PNRKP 4-RKP 4RKP -4RKP -RKP -RKP RKP -RKP -RKP -RKP RKP -RKP -RKP -RKP RKP PN4-FP PN4FP PN-4FP PN-FP PN-FP PNFP PN-FP PN-FP PN-FP PNFP PN-FP PN-FP PN-FP PN-FP PNFP 4-FP 4FP -4FP -FP -FP FP -FP -FP -FP FP -FP -FP -FP -FP FP PN4... PN 4... PN... PN..4.. s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Housings of nodular graphite cast iron are also available

103 Light Pillow lock Units LP Cylindrical bore (with set screws) d ~ 4 LP Cylindrical bore (with eccentric locking collar) Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs LP~LP ±. N N H H LP LP LP H L J L LP haft Dia. Dimensions olt Unit earing Unit earing Housing asic Factor Mass inch inch ize No. No. No. No. No. Load Ratings kn kg inch LP LP Cr Cr f LP LP d H L J N N H H L LP LP / 4 / /... LP- - LP- - LP LP LP M LP- - LP- - LP LP 4 / / / / / /. /. / / / / / 4 4 / / / 4 / 4 / 4 / / Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). llowable load to housing in radial direction is approximately half of basic load rating of bearing, Cr (when safety factor is 4).. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. / 4 / M M M M M LP4- LP4 LP-4 LP- LP LP- LP- LP LP- LP- LP- LP- LP LP- LP-4 LP LP4- LP4 LP-4 LP- LP LP- LP- LP LP- LP- LP- LP- LP- LP LP- LP-4 LP- LP LP LP LP..... LP LP

104 Compact Pillow lock Units UP Cylindrical bore (with set screws) d ~ With Through Type Cover With One ide ealed Cover Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. Hs Js P~P ±. ±. H H -φ N H L J L haft Dia. Dimensions olt tandard asic Factor With Rubber Coated Cover inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn inch inch Open Type One ide d H L J N H H L kg Cr Cr f Closed Type s kg 4 / 4 / 4 / 4 4 / 4 4 / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. / M M M M / M / M M UP P U UPC UPCD. UP P U...4. UPC UPCD. UP P U.... UPC UPCD. UP P U UPC UPCD /. UP4 P4 U UP4C UP4CD. UP P U UPC UPCD 4 /. UP P U UPC UPCD 44.4

105 Corrosion Resistant eries Pillow lock Units UCP-H Cylindrical bore (with set screws) d ~ With Pressed tainless teel Cover Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs PH~PH ±. PH~PH ±. N N H H H L J L haft Dia. Dimensions olt tandard asic Factor With Pressed tainless teel Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn inch inch Open Type One ide d H L J N N H H L kg Cr Cr f Closed Type s kg 4 4 /. / / / / / / / / / /. /. / / / 4 4 / / / / 4 / / / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is are shown below. --UNFN... X~ -RN... ~. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. / / / 4 / 4 / / / 4 4 / 4 4 / M M M M4 M4 M4 M4 M M M UCPXH UCP-XH UCPXH UCP-XH UCPXH UCP4-H UCP4H UCP-4H UCP-H UCPH UCP-H UCP-H UCPH UCP-H UCP-H UCP-H UCP-H UCP-H UCPH UCP-H UCP-4H UCP-H UCPH UCP-H UCP-H UCP-H UCPH UCP-H UCP-H UCPH UCP-H UCP-H UCP-4H UCPH UCP-H UCP-H UCPH UCP-H UCP-H PH P4H PH PH PH PH PH PH PH PH UCX UC-X UCX UC-X UCX UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC- UC- UC-4 UC UC- UC- UC UC- UC UCP4HC UCP4HCD UCPHC UCPHC UCPHC UCPHC UCPHC UCPHC UCPHC UCPHC UCPHCD UCPHCD UCPHCD UCPHCD UCPHCD UCPHCD UCPHCD UCPHCD 4 4 /

106 Corrosion Resistant eries Pillow lock Units UCP-H Cylindrical bore (with set screws) d ~ 4 With Pressed tainless teel Cover Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. Hs Js PH~PH ±. ±. H H H H L J L -N haft Dia. Dimensions tandard asic Factor With Pressed tainless teel Cover inch inch Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn inch Open Type One ide d H L J N H H H L kg Cr Cr f Closed Type s kg 4 /. / / / / / /. /. / / 4. / 4 / / / / / / 4 M. M. M. M4 M4 / 4 M4 / 4 / 4 / UCPXH UCP-XH UCPXH UCP-XH UCPXH UCP4-H UCP4H UCP-4H UCP-H UCPH UCP-H UCP-H UCPH UCP-H UCP-H UCP-H UCP-H UCP-H UCPH UCP-H UCP-4H UCP-H UCPH Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. / PH P4H PH PH PH PH UCX UC-X UCX UC-X UCX UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UCP4HC UCPHC UCPHC UCPHC UCPHC UCP4HCD UCPHCD UCPHCD UCPHCD UCPHCD 4 4 /.4....

107 Corrosion Resistant eries Pillow lock Units UP- Cylindrical bore (with set screws) d ~ With Through Type Cover With One ide ealed Cover Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. Hs Js P~P ±. ±. H H -φn H L J L haft Dia. Dimensions olt tandard asic Factor With Rubber Coated Cover inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn inch inch Open Type One ide d H L J N H H L kg Cr Cr f Closed Type s kg 4 / 4 / 4 / 4 / / / / / 4. / /. / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. M M M M / M / M M UP P U.... UPC UPCD. UP P U UPC UPCD. UP P U UPC UPCD. UP P U UPC UPCD /.4 UP4 P4 U UP4C UP4CD. UP P U UPC UPCD 4 /. UP P U UPC UPCD 44.4

108 Corrosion Resistant eries Pillow lock Units UCVP- Cylindrical bore (with set screws) d ~ N Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs VP4~VP ±. VP~VP ±. N H H H L J L haft Dia. Dimensions olt tandard asic Factor With Plastic Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn inch inch Open Type One ide d H L J N N H H kg Cr Cr f Closed Type s kg 4 4 / / / / / / / /. /. / / / / / 4 / / / 4 / 4 / 4 / 4 / 4 / 4. /... / / M M M M M M4 M4 UCVP4- UCVP4 UCVP-4 UCVP- UCVP UCVP- UCVP- UCVP UCVP- UCVP- UCVP- UCVP- UCVP- UCVP UCVP- UCVP-4 UCVP- UCVP UCVP- UCVP- UCVP- UCVP UCVP- UCVP- UCVP UCVP- Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. VP4 VP VP VP VP VP VP UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC UCVP4-C UCVP4C UCVP-4C UCVP-C UCVPC UCVP-C UCVP-C UCVPC UCVP-C UCVP-C UCVP-C UCVP-C UCVP-C UCVPC UCVP-C UCVP-4C UCVP-C UCVPC UCVP-C UCVP-C UCVP-C UCVPC UCVP-C UCVP-C UCVPC UCVP-C UCVP4-CD UCVP4CD UCVP-4CD UCVP-CD UCVPCD UCVP-CD UCVP-CD UCVPCD UCVP-CD UCVP-CD UCVP-CD UCVP-CD UCVP-CD UCVPCD UCVP-CD UCVP-4CD UCVP-CD UCVPCD UCVP-CD UCVP-CD UCVP-CD UCVPCD UCVP-CD UCVP-CD UCVPCD UCVP-CD. /

109 Corrosion Resistant eries Pillow lock Units UCVP-E Cylindrical bore (with set screws) d ~ N Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) Housing No. Hs VP4E~VPE ±. VPE~VPE ±. N H H H L J L haft Dia. Dimensions olt tandard asic Factor With Plastic Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn inch inch Open Type One ide d H L J N N H H kg Cr Cr f Closed Type s kg 4 4 / / / / / / / /. /. / / / / / 4 / / / 4 / 4 / 4 / 4 / 4 / 4. /... / / M M M M M M4 M4 UCVP4-E UCVP4E UCVP-4E UCVP-E UCVPE UCVP-E UCVP-E UCVPE UCVP-E UCVP-E UCVP-E UCVP-E UCVP-E UCVPE UCVP-E UCVP-4E UCVP-E UCVPE UCVP-E UCVP-E UCVP-E UCVPE UCVP-E UCVP-E UCVPE UCVP-E Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. VP4E VPE VPE VPE VPE VPE VPE UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC UCVP4-EC UCVP4EC UCVP-4EC UCVP-EC UCVPEC UCVP-EC UCVP-EC UCVPEC UCVP-EC UCVP-EC UCVP-EC UCVP-EC UCVP-EC UCVPEC UCVP-EC UCVP-4EC UCVP-EC UCVPEC UCVP-EC UCVP-EC UCVP-EC UCVPEC UCVP-EC UCVP-EC UCVPEC UCVP-EC UCVP4-ECD UCVP4ECD UCVP-4ECD UCVP-ECD UCVPECD UCVP-ECD UCVP-ECD UCVPCD UCVP-ECD UCVP-ECD UCVP-ECD UCVP-ECD UCVP-ECD UCVPECD UCVP-ECD UCVP-4ECD UCVP-ECD UCVPECD UCVP-ECD UCVP-ECD UCVP-ECD UCVPECD UCVP-ECD UCVP-ECD UCVPECD UCVP-ECD. /

110 Corrosion Resistant eries Pillow lock Units UCVPN-E Cylindrical bore (with set screws) d ~ H H H J L -N haft Dia. Dimensions tandard asic Factor With Plastic Cover inch inch Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn inch Open Type One ide d H L J N H H kg Cr Cr f Closed Type s kg / / / / /. /. / /. / UNC -UNC /-4UNC -UNC / UCVPN4-E UCVPN4E UCVPN-4E UCVPN-E UCVPNE UCVPN-E UCVPN-E UCVPNE UCVPN-E UCVPN-E UCVPN-E UCVPN-E UCVPN-E UCVPNE UCVPN-E Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. VPN4E VPNE VPNE VPNE UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC UCVPN4-EC UCVPN4EC UCVPN-4EC UCVPN-EC UCVPNEC UCVPN-EC UCVPN-EC UCVPNEC UCVPN-EC UCVPN-EC UCVPN-EC UCVPN-EC UCVPN-EC UCVPNEC UCVPN-EC UCVPN4-ECD UCVPN4ECD UCVPN-4ECD UCVPN-ECD UCVPNECD UCVPN-ECD UCVPN-ECD UCVPNCD UCVPN-ECD UCVPN-ECD UCVPN-ECD UCVPN-ECD UCVPN-ECD UCVPNECD UCVPN-ECD

111 tamped teel Pillow lock Units PP Cylindrical bore (with set screws) d ~ PP Cylindrical bore (with eccentric locking collar) Variations of tolerance of distance between centers of bolt holes (Js) and variations of tolerance of bolt hole diameter (Ns) Housing No. Js Ns PP~PP ±.4 ±. H -φ N H H J L PP PP PP PP haft Dia Dimensions olt Unit earing Unit earing Housing asic Factor Mass inch inch ize No. No. No. No. No. Load Ratings kn kg inch PP PP Cr Cr f PP PP d H L J N H H PP PP 4... PP- - PP- - / PP PP PP M PP- - PP- - PP PP / / Remark.4. / For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit / M M M PP4- PP4 4-4 PP-4-4 PP- - PP PP- - PP- - PP PP- - PP- - PP4- PP4 4-4 PP-4-4 PP- - PP PP- - PP- - PP PP- - PP- - PP PP PP....4.

112 4-olt Flange Units UCF Cylindrical bore (with set screws) d ~ (4) 4-φN L J With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F4~F FX~FX F~F ±.. F~F FX~FX F~F ±. L J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4~F FX~FX F~F ±. FX F~F ±. haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch d L J N kg Cr Cr f s kg c kg 4 4 / / / / / / / / / / 4. / / 4 4 / 4 / 4 / / / / 4 / 4 / / / 4. / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ / 4 /. / M M M M4 M M4 M4 / M M4 M M4 M M M4 M UCF UCF- UCF UCF- UCF UCF4- UCF4 UCF-4 UCF- UCF UCF- UCFX UCFX- UCF UCF- UCF- UCF UCF- UCF- UCFX UCFX- UCFX- F4 F FX F F FX UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UCX UCX- UC UC- UC- UC UC- UC- UCX UCX- UCX UCFC UCFC UCFC UCF4C UCFC UCFXC UCFC UCFXC UCFD UCFD UCFD UCF4D UCFD UCFXD UCFD UCFXD / UCF4FC UCFFC UCFC UCFFC UCF4FD UCFFD UCFD UCFFD UCF F UC.... UCFC UCFD /. UCF- UCF- UCF- UCF UCF- UCFX- UCFX UCFX- F FX UC- UC- UC- UC UC- UCX- UCX UCX UCFC UCFXC UCFD UCFXD 4. / /.. UCFFC UCFFD UCF F UC..4.. UCFC UCFD 4. UCF-4 UCF- UCF UCFX-4 UCFX UCF-4 UCF UCF- UCF- UCF- UCF UCFX- UCFX- UCFX F FX F F FX UC-4 UC- UC UCX-4 UCX UC-4 UC UC- UC- UC- UC UCX- UCX- UCX UCFC UCFXC UCFC UCFXC UCFD UCFXD UCFD UCFXD... /..4.. UCFFC UCFC UCFFC UCFFD UCFD UCFFD. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCFJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available / /

113 4-olt Flange Units UCF Cylindrical bore (with set screws) d (4) ~ () 4-φN L J With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F4~F FX~FX F~F ±.. F~F FX~FX F~F ±. L J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4~F FX~FX F~F ±. FX F~F ±. haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch d L J N kg Cr Cr f s kg c kg 4 / / 4 / / / / / / / / / / / 44 / / 4 / 4 / 4 / / 4 / / / / 4 / /.4... /..4 /.4. / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ / 4 4 / M M4 M M M M M M M M M M M M M M M M UCF- UCF UCF- UCF- UCF UCF- UCFX- UCFX UCFX- F F FX UC- UC UC- UC- UC UC- UCX- UCX UCX UCFC UCFXC UCFD UCFXD 4 /.. UCFC UCFFC UCFD UCFFD UCF F UC.... UCFC UCFD. UCF- UCF-4 UCF UCF- UCFX UCFX- UCFX- UCF- UCF UCF- UCF- UCF UCF- UCF- UCFX UCFX- UCF UCF- UCF-4 UCF UCFX-4 UCFX UCF-4 UCF UCF4-44 UCF4 UCFX4-44 UCFX4 UCF4-44 UCF4 UCF-4 UCF UCF-4 UCFX-4 UCFX UCFX-4 F FX F F FX F F FX F F4 FX4 F4 F FX UC- UC-4 UC UC- UCX UCX- UCX- UC- UC UC- UC- UC UC- UC- UCX UCX- UC UC- UC-4 UC UCX-4 UCX UC-4 UC UC4-44 UC4 UCX4-44 UCX4 UC4-44 UC4 UC-4 UC UC-4 UCX-4 UCX UCX UCFC UCFXC UCFC UCFXC UCFC UCFXC UCF4C UCFX4C UCFC UCFXC UCFD UCFXD UCFD UCFXD UCFD UCFXD UCF4D UCFX4D UCFD UCFXD / UCFFC UCFC UCFFC UCFC UCFFC UCFC UCF4FC UCF4C UCFFC UCFFD UCFD UCFFD UCFD UCFFD UCFD UCF4FD UCF4D UCFFD / / / /. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCFJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available

114 4-olt Flange Units UCF Cylindrical bore (with set screws) d () ~ 4 4-φN L J With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F4~F FX~FX F~F ±.. F~F FX~FX F~F ±. L J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4~F FX~FX F~F ±. FX F~F ±. haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch d L J N kg Cr Cr f s kg c kg / / / 4 / / 4 / 4 / 4 / 4 4 / 4 4 / 4 4 / 4 / / 4 / / 4 / / / 4 / / 4 / 4 / / 4 / / / / 4 / / / /.. /.. /. 4 /. / M M M M M M M M M M M M M M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ UCF-4 UCF UCF-4 UCF- UCF F F UC-4 UC UC-4 UC- UC UCFC UCFD.. UCFC UCFFC UCFD UCFFD UCFX FX UCX UCFXC UCFXD. /.4 UCF F UC... UCFC UCFD 4 4. UCF- UCF UCFX UCFX- F FX UC- UC UCX UCX UCFC UCFXC UCFD UCFXD UCFFC UCFFD UCF F UC... UCFC UCFD 4. UCF- UCF F UC- UC UCFC UCFD. 4.4 UCFFC UCFFD UCFX FX UCX UCFXC UCFXC 4 4. UCF- UCF F UC- UC.. 4. UCF F UC.. UCFC UCFD 4. UCFX UCFX- UCFX-4 UCF UCF- UCF-4 FX F UCX UCX- UCX-4 UC UC- UC UCF F UC. 4. UCFC UCFD 4 /. UCF F UC.. UCFC UCFD 4 / 4. UCF4 F4 UC4 4.. UCF4C UCF4D. UCF F UC. 4. UCFC UCFD. UCF F UC.4 4. UCFC UCFD / UCFC UCFXC UCFC UCFD UCFXD UCFD. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCFJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available. 4 4 / 4 / 4 4 / 4 /

115 4-olt Flange Units UCF-E Cylindrical bore (with set screws) d ~ 4-φN L J Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F4E~FE FXE~FXE ±.. FE~FE FXE~FXE ±. L J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4E~FE FXE~FXE ±. haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d L J N Cr Cr f kg 4 4 / / / / / / / / / / / 4 4. / / 4 4 / 4 / 4 / / 4. / / 4 / 4 / 4 / / /. /. / Remarks. In Part No. of unit, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X -R... ~, X~X / / / / / UCFE UCF-E UCFE UCF-E UCFE UCF4-E UCF4E UCF-4E UCF-E UCFE UCF-E UCFXE UCFX-E UCF-E UCFE UCF-E UCF-E UCFXE UCFX-E UCFX-E UCF-E UCF-E UCF-E UCFE UCF-E UCFX-E UCFXE UCFX-E UCF-4E UCF-E UCFE UCFX-4E UCFXE UCF-E UCF-E UCF-E UCFE UCFX-E UCFX-E UCFXE UCF-E UCF-E UCFE UCF-E UCFX-E UCFXE UCFX-E F4E FE FXE FE FXE FE FXE FE FXE FE FXE FE FXE UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UCX UCX- UC- UC UC- UC- UCX UCX- UCX- UC- UC- UC- UC UC- UCX- UCX UCX- UC-4 UC- UC UCX-4 UCX UC- UC- UC- UC UCX- UCX- UCX UC- UC- UC UC- UCX- UCX UCX s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCFEJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available. 44 4

116 4-olt Flange Units UCF-E Cylindrical bore (with set screws) d ~ 4-φN L J Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F4E~FE FXE~FXE ±.. FE~FE FXE~FXE ±. L J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4E~FE FXE~FXE ±. haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d L J N Cr Cr f kg / / / / / / / / 4 / 4 / / 4 / 4 4 / 4 / / / / 4 / 4 / 4 4 / 4 4 / 4 4 / 4 / 4 / / Remarks. In Part No. of unit, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X -R... ~, X~X / / / / / / / UCF-E UCF-4E UCFE UCF-E UCFXE UCFX-E UCFX-E UCF-E UCFE UCF-E UCF-E UCFXE UCFX-E UCF-4E UCFE UCFX-4E UCFXE UCF4-44E UCF4E UCFX4-44E UCFX4E UCF-4E UCFE UCF-4E UCFX-4E UCFXE UCFX-4E UCF-E UCFE FE FXE FE FXE FE FXE F4E FX4E FE FXE FE UC- UC-4 UC UC- UCX UCX- UCX- UC- UC UC- UC- UCX UCX- UC-4 UC UCX-4 UCX UC4-44 UC4 UCX4-44 UCX4 UC-4 UC UC-4 UCX-4 UCX UCX-4 UC- UC / UCFXE FXE UCX / / UCF-E UCFE UCFXE UCFX-E FE FXE UC- UC UCX UCX s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCFEJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available. 4 4

117 4-olt Flange Units NNF Cylindrical bore (with eccentric locking collar) d ~ 4-φN L J Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X NF4~NF ±.. NF~NF ±. L J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns NF4~NF ±. haft Dia Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d L J N Cr Cr f kg 4 4 / / / / / / / / / /. / / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... ~. / 4 / /. / / / / / / NNF NNF- NNF NNF- NNF NNF4- NNF4 NNF-4 NNF- NNF NNF- NNF- NNF NNF- NNF- NNF- NNF- NNF- NNF NNF- NNF-4 NNF- NNF NNF- NNF- NNF- NNF NNF- NNF- NNF NNF- NNF- NNF-4 NNF NNF- NNF- NNF NNF- NNF- NF4 NF NF NF NF NF NF NF NF N N- N N- N N4- N4 N-4 N- N N- N- N N- N- N- N- N- N N- N-4 N- N N- N- N- N N- N- N N- N- N-4 N N- N- N N- N For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Housings of nodular graphite cast iron are also available. 4 4

118 4-olt Flange Units NCF Cylindrical bore (with concentric locking collar) d ~ 4-φN L J Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F4~F ±.. F~F ±. L J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4~F ±. haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d L J N d Cr Cr f kg 4 4 / / 4 4 / 4 / / 4 / /. / 4 4 / 4 / 4 / / / 4 / /. / Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R... ~ 44. / 4. /. /. /. /. /.4 / / M M M / M / M M4 M4 M4 M4 M M M M NCF4- NCF4 NCF-4 NCF- NCF NCF- NCF- NCF NCF- NCF- F4 F F NC4- NC4 NC-4 NC- NC NC- NC- NC NC- NC NCF- F NC NCF- NCF NCF- NCF-4 NCF F F NC- NC NC- NC-4 NC NCF- F NC NCF- NCF- NCF NCF- NCF NCF- F F NC- NC- NC NC- NC NC NCF- F NC NCF NCF- F NC NC NCF- F NC NCF NCF- F NC NC For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated.

119 4-olt Flange Units NCF-E Cylindrical bore (with concentric locking collar) d ~ 4-φN L J Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F4E~FE ±.. FE~FE ±. L J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4E~FE ±. haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d L J N d Cr Cr f kg 4 4 / / 4 4 / 4 / / 4 / /. / 4 4 / 4 / 4 / / / / 4 / /. / Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R... ~ 44. / 4. /. /. /. /. /.4 / / / NCF4-E NCF4E NCF-4E NCF-E NCFE NCF-E NCF-E NCFE NCF-E NCF-E F4E FE FE NC4- NC4 NC-4 NC- NC NC- NC- NC NC- NC / NCF-E FE NC / NCF-E NCFE NCF-E NCF-4E NCFE FE FE NC- NC NC- NC-4 NC NCF-E FE NC NCF-E NCF-E NCFE NCF-E NCFE NCF-E FE FE NC- NC- NC NC- NC NC NCF-E FE NC NCFE NCF-E FE NC NC NCF-E FE NC NCFE NCF-E FE NC NC For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated.

120 4-olt Flange Units UKF Tapered bore (with adapter) d ~ () 4-φN L J With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F~F FX~FX F~F ±.. F~F FX~FX F~F ±. e L J e e Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F~F FX~FX F~F ±. FX F~F ±. haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch de d L J N kg Cr Cr f s kg c kg (min.) / / HEX. UKF F UK 4... M HX. UKFC UKFD 4.. UKFFC UKFFD 4 /. 4 / 4 / / HEX. UKFX FX UKX.... M HX. UKFXC UKFXD HEX.4 UKF F UK.... M4 HX.4 UKFC UKFD / HX. UKFC UKFD 44. UKF F UK.... UKFFC UKFFD.. M HEX. 4 / HX. UKFXC UKFXD 4 UKFX FX UKX..4. / M4 HEX HX. UKFC UKFD UKF F UK... /. 4 M4 HEX. 4 / / / HX. UKF F UK M HX. UKFC UKFD 4 /. UKFFC UKFFD. 4 / / HX. UKFX FX UKX M4 HX. UKFXC UKFXD. /. / / / HX. UKF F UK M HX. UKFC UKFD 4. HEX. UKF F UK HX / 4 / 4 / 4 / 4 44 / / 4 / / 4 / 4 4. / / / 4 / 4 / 4 Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~. 4. / / / 4 / 4 / / 4 4 M4 M M M4 M M M4 M M M M UKFX FX UKX UKF F UK UKF F UK UKFX FX UKX UKF F UK UKF F UK UKFX FX UKX UKF F UK UKF F UK UKFX FX UKX HX HEX HX HX HEX HX HX HEX HX HEX HX HEX HX HEX HX HEX HX HEX HX HX HX HEX HX HX HEX UKFC UKFXC UKFC UKFXC UKFC UKFXC UKFC UKFXC UKFD UKFXD UKFD UKFXD UKFD UKFXD UKFD UKFXD / / UKFFC UKFC UKFFC UKFC UKFFC UKFC UKFFC UKFFD UKFD UKFFD UKFD UKFFD UKFD UKFFD /. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKFJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UKFJL + HX, UKL + HX). For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Housings of nodular graphite cast iron are also available

121 4-olt Flange Units UKF Tapered bore (with adapter) d () ~ () 4-φN L J With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F~F FX~FX F~F ±.. F~F FX~FX F~F ±. e L J e e Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F~F FX~FX F~F ±. FX F~F ±. haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch de d L J N kg Cr Cr f s kg c kg (min.) / / / / 4 / 4 / 4 / / 4 / / / / 4 / / 4 / / / / / 4 / 4 / / 4 / 4 / / 4 / / / 4 / 4 4 / 4 4 / 4 / / /.. / /. / / / / / / / / / / / / / M M M M M M M M M M M M M M M M M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ UKF F UK UKF F UK UKFX FX UKX UKF F UK UKF F UK UKFX FX UKX UKF F UK UKF F UK UKFX FX UKX UKF F UK UKF F UK UKFX FX UKX UKF F UK UKF F UK UKFX FX UKX UKF F UK HX HX HEX HX HX HX HX HX HX HEX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HEX HX HEX HX HEX HX HEX HX HX HEX HX HEX HX HEX UKFC UKFXC UKFC UKFXC UKFC UKFXC UKFC UKFXC UKFC UKFXC UKFD UKFXD UKFD UKFXD UKFD UKFXD UKFD UKFXD UKFD UKFXD / UKFC UKFFC UKFC UKFFC UKFC UKFFC UKFC UKFFC UKFC UKFFC UKFC UKFD UKFFD UKFD UKFFD UKFD UKFFD UKFD UKFFD UKFD UKFFD UKFD UKF F UK HX UKFC UKFD. 4.4 UKFFC UKFFD 4 /. UKFX FX UKX HX UKFXC UKFXD 4 4. UKF F UK HX. 4. UKFC UKFD 4 /. UKF F UK UKFX FX UKX HEX HX HEX HX UKFC UKFXC UKFD UKFXD. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKFJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UKFJL + HX, UKL + HX). For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Housings of nodular graphite cast iron are also available. 4 4 / / / 4 / 4 /

122 4-olt Flange Units UKF Tapered bore (with adapter) d () ~ 4-φN L J With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F~F FX~FX F~F ±.. F~F FX~FX F~F ±. e L J e e Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F~F FX~FX F~F ±. FX F~F ±. haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch de d L J N kg Cr Cr f s kg c kg (min.) / 4 / / HEX.4 UKF F UK M HX.4 UKFC UKFD HX. UKFC UKFD 4 UKF F UK. / M HEX. 4 / 4 / / M UKF4 F4 UK4 H4 4.. UKF4C UKF4D. 4 4 / / 4 HE. UKF F UK M H. UKFC UKFD. 4 / M UKF F UK H UKFC UKFD /. Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKFJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UKFJL + HX, UKL + HX). For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Housings of nodular graphite cast iron are also available.

123 quare Piloted 4-olt Flange Units UCF Cylindrical bore (with set screws) d ~ 4 φh 4 4-φ N L J L J φh With Cast Iron Cover 4 C Variations of tolerance of spigot joint outside diameter (Hs), variations of tolerance of distance from mounting surface to center of spherical bore (s), tolerance of position of bolt hole (X), and tolerance of circumferential runout of spigot joint (Y) Housing No. Hs s X Y F.4 F~F ±....4 F~F F~F F4~F F~F F4~F.. ~F. ±. F~..4. Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F~ ±. F~ ±. haft Dia. Dimensions olt tandard asic Factor With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d L H J N 4 kg Cr Cr f c kg 4 4 / 4 4 / / / / / / / / / / / / / / 4 4 / / 4 / / / / / / / 4 / / / 4 / 4 / / 4 / 4 / / 4 4 / M4 M4 M M M M M M M M M M M M M M M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... ~ UCF UCF- F UC UC UCFC UCFD UCF F UC.... UCFC UCFD. UCF F UC..4.. UCFC UCFD. UCF-4 UCF UCF- UCF F F UC-4 UC UC- UC UCFC UCFC UCFD UCFD UCF F UC.... UCFC UCFD. UCF- UCF UCF- UCF UCF- UCF-4 UCF UCF4-44 UCF4 UCF-4 UCF UCF-4 F F F F4 F UC- UC UC- UC UC- UC-4 UC UC4-44 UC4 UC-4 UC UC UCFC UCFC UCFC UCF4C UCFC UCFD UCFD UCFD UCF4D UCFD UCF F UC... UCFC UCFD /. UCF F UC... UCFC UCFD /. UCF- UCF F UC- UC.. 4. UCFC UCFD UCF F UC 4.. UCFC UCFD 4. UCF UCF- UCF-4 F UC UC- UC UCFC UCFD UCF F UC. 4. UCFC UCFD. UCF F UC.. UCFC UCFD 4.4 UCF4 F4 UC4.. UCF4C UCF4D.4 UCF F UC. 4. UCFC UCFD 4. UCF F UC UCFC UCFD 4 4 / / s for the triple seal type product, suffix code L follows the Part No. of unit or bearing. (Example of Part No. : UCFJL, UCL) 4. The dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available..

124 quare Piloted 4-olt Flange Units UKF Tapered bore (with adapter) d ~ φh 4 4-φ N L J L J φh With Cast Iron Cover 4 C Variations of tolerance of spigot joint outside diameter (Hs), variations of tolerance of distance from mounting surface to center of spherical bore (s), tolerance of position of bolt hole (X), and tolerance of circumferential runout of spigot joint (Y) Housing No. Hs s X Y F.4 F~F ±....4 F~F F~F F~F F~F F4~F.. ~F. ±. F~..4. Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F~ ±. F~ ±. haft Dia. Dimensions olt tandard asic Factor With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass No. No. No. No. kn Open Type Closed Type inch inch d L H J N 4 kg Cr Cr f c kg / / / / / / / / / / / 4 4 / / 4 / / / / / / / 4 / / / 4 / /. / / / / 4 / 4 / / / / / M4 M4 M M M M M M M M M M M M M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... ~ UKF F UK UKF F UK UKF F UK UKF F UK UKF F UK UKF F UK UKF F UK UKF F UK UKF F UK UKF F UK UKF F UK UKF F UK HEX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HX HEX UKFC UKFC UKFC UKFC UKFC UKFC UKFC UKFC UKFC UKFC UKFC UKFC UKFD UKFD UKFD UKFD UKFD UKFD UKFD UKFD UKFD UKFD UKFD UKFD UKF F UK HX.4 4. UKFC UKFD. UKF F UK UKF F UK UKF F UK HEX HX HEX HX HX HEX UKFC UKFC UKFC UKFD UKFD UKFD UKF4 F4 UK4 H4.. UKF4C UKF4D. UKF F UK HE H.. 4. UKFC UKFD UKF F UK H UKFC UKFD. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKFJ + HX, UK + HX) 4. s for the triple seal type product, suffix code L follows the Part No. of unit or bearing. (Example of Part No. : UKFJL + HX, UKL + HX). For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Housings of nodular graphite cast iron are also available / / / /

125 Narrow Inner Ring earing 4-olt Flange Units F-RKP Cylindrical bore (with set screws) d ~ F-FP Cylindrical bore (with eccentric locking collar) 4-φN L J 4-φN L J Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F4~F ±.. F ±. L J L J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4~F ±. F-RKP F-FP F-RKP F-FP haft Dia. Dimensions olt Unit earing Unit earing Housing asic Factor Mass inch inch ize No. No. No. No. No. Load Ratings kn kg inch F-RKP F-FP Cr Cr f F-RKP F-FP d L J N /.4... F4-RKP 4-RKP F4-FP 4-FP F M F4RKP 4RKP F4FP 4FP F-4RKP -4RKP F-4FP -4FP. / / /.... F-RKP -RKP F-FP -FP. F M F-RKP -RKP F-FP -FP. FRKP RKP FFP FP. 4 4 / / / / / / / / 4 / Remarks. In Part No. of unit, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R M / M M4 M4 M4 M F-RKP F-RKP F-RKP FRKP F-RKP F-RKP F-RKP FRKP F-4RKP FRKP -RKP -RKP -RKP RKP -RKP -RKP -RKP RKP -4RKP RKP F-FP F-FP F-FP FFP F-FP F-FP F-FP F-FP FFP F-4FP F-FP FFP F-FP F-FP F-FP FFP F-FP F-FP FFP F-FP F-4FP F-FP FFP -FP -FP -FP FP -FP -FP -FP -FP FP -4FP -FP FP -FP -FP -FP FP -FP -FP FP -FP -4FP -FP FP F..... F..4. F For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Housings of nodular graphite cast iron are also available F F F

126 Corrosion Resistant eries 4-olt Flange Units UCF-H Cylindrical bore (with set screws) d ~ 4-φN L J With Pressed tainless teel Cover Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F4H~H ±.. FH~H ±. L J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4H~H ±. haft Dia. Dimensions olt tandard asic Factor With Pressed tainless teel Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d L J N kg Cr Cr f s kg 4 4 / / / / / / / / / / 4 / / 4 / /. 4. / M M M / M M4 M4 M4 M UCF4-H UCF4H UCF-4H UCF-H UCFH UCF-H UCF-H UCFH UCF-H UCF-H UCF-H UCF-H UCF-H UCFH UCF-H UCF-4H UCF-H UCFH UCF-H UCF-H UCF-H UCFH UCF-H UCF-H UCFH UCF-H UCF-H UCF-4H UCFH UCF-H UCF-H UCFH UCF-H UCF-H Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is are shown below. --UNFN... 4~ -RN... ~. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit M F4H FH FH FH FH FH FH FH FH UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC- UC- UC-4 UC UC- UC- UC UC- UC UCF4HC UCFHC UCFHC UCFHC UCFHC UCFHC UCFHC UCFHC UCFHC UCF4HD UCFHD UCFHD UCFHD UCFHD UCFHD UCFHD UCFHD UCFHD / / /

127 Corrosion Resistant eries 4-olt Flange Units UCF-EH Cylindrical bore (with set screws) d ~ 4-φN L J With Pressed tainless teel Cover Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X F4EH~EH ±.. FEH~EH ±. L J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4EH~EH ±. haft Dia. Dimensions olt tandard asic Factor With Pressed tainless teel Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d L J N kg Cr Cr f s kg 4 4 / / / / / / / / / / 4 / / / 4 / /. 4. / / / UCF4-EH UCF4EH UCF-4EH UCF-EH UCFEH UCF-EH UCF-EH UCFEH UCF-EH UCF-EH UCF-EH UCF-EH UCF-EH UCFEH UCF-EH UCF-4EH UCF-EH UCFEH UCF-EH UCF-EH UCF-EH UCFEH UCF-EH UCF-EH UCFEH UCF-EH UCF-EH UCF-4EH UCFEH UCF-EH UCF-EH UCFEH UCF-EH UCF-EH Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is are shown below. --UNFN... 4~ -RN... ~. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit F4EH FEH FEH FEH FEH FEH FEH FEH FEH UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC- UC- UC-4 UC UC- UC- UC UC- UC UCF4EHC UCFEHC UCFEHC UCFEHC UCFEHC UCFEHC UCFEHC UCFEHC UCFEHC UCF4EHD UCFEHD UCFEHD UCFEHD UCFEHD UCFEHD UCFEHD UCFEHD UCFEHD / / /

128 Corrosion Resistant eries 4-olt Flange Units UCVF- Cylindrical bore (with set screws) d ~ 4 4-φN L J Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X VF4~VF ±.. L J haft Dia. Dimensions olt tandard asic Factor With Plastic Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d L J N kg Cr Cr f s kg 4 / / / / / /.. 4 / / / 4.4. / /. / M M M M M UCVF4- UCVF4 UCVF-4 UCVF- UCVF UCVF- UCVF- UCVF UCVF- UCVF- UCVF- UCVF- UCVF- UCVF UCVF- UCVF-4 UCVF- UCVF Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. VF4 VF VF VF VF UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UCVF4-C UCVF4C UCVF-4C UCVF-C UCVFC UCVF-C UCVF-C UCVFC UCVF-C UCVF-C UCVF-C UCVF-C UCVF-C UCVFC UCVF-C UCVF-4C UCVF-C UCVFC UCVF4-D UCVF4D UCVF-4D UCVF-D UCVFD UCVF-D UCVF-D UCVFD UCVF-D UCVF-D UCVF-D UCVF-D UCVF-D UCVFD UCVF-D UCVF-4D UCVF-D UCVFD

129 Corrosion Resistant eries 4-olt Flange Units UCVF-E Cylindrical bore (with set screws) d ~ 4 4-φN L J Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X VF4E~VFE ±.. L J haft Dia. Dimensions olt tandard asic Factor With Plastic Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d L J N kg Cr Cr f s kg 4 / / / / / /.. 4 / / / 4.4. / /. / M / M / M M UCVF4-E UCVF4E UCVF-4E UCVF-E UCVFE UCVF-E UCVF-E UCVFE UCVF-E UCVF-E UCVF-E UCVF-E UCVF-E UCVFE UCVF-E UCVF-4E UCVF-E UCVFE Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit M VF4E VFE VFE VFE VFE UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UCVF4-EC UCVF4EC UCVF-4EC UCVF-EC UCVFEC UCVF-EC UCVF-EC UCVFEC UCVF-EC UCVF-EC UCVF-EC UCVF-EC UCVF-EC UCVFEC UCVF-EC UCVF-4EC UCVF-EC UCVFEC UCVF4-ED UCVF4ED UCVF-4ED UCVF-ED UCVFED UCVF-ED UCVF-ED UCVFED UCVF-ED UCVF-ED UCVF-ED UCVF-ED UCVF-ED UCVFED UCVF-ED UCVF-4ED UCVF-ED UCVFED /.....

130 -olt Flange Units UCFL Cylindrical bore (with set screws) d ~ (4) With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X FL4~FL FLX~FLX FL~FL ±.. FL~FL FL~FL4 ±. -φn L Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FL4~FL FLX~FLX FL~FL ±. FL~FL4 ±. Forms and dimensions of Lc of FL4JE and FLJE (housing with cast iron cover) are shown below. J H L c FL4JE Lc = FLJE Lc = haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch d H L J N kg Cr Cr f s kg c kg / / / / / / / 4 / / 4 / 4 / / / / / 4 / / /. / / 4 4 / 4 / 4 / / / / 4 / 4 / 4 / 4 / / / 4. / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X, ~4 / 4 /. / M M4 M M M4 M4 M M4 M4 M M4 M4 M M M4 UCFL UCFL- UCFL UCFL- UCFL UCFL4- UCFL4 UCFL-4 UCFL- UCFL UCFL- UCFLX UCFLX- UCFL UCFL- UCFL- UCFL UCFL- UCFL- UCFLX UCFLX- UCFLX- FL4 FL FLX FL FL FLX UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UCX UCX- UC UC- UC- UC UC- UC- UCX UCX- UCX UCFLC UCFLC UCFLC UCFL4C UCFLC UCFLXC UCFLC UCFLXC UCFLD UCFLD UCFLD UCFL4D UCFLD UCFLXD UCFLD UCFLXD / UCFL4FC UCFLFC UCFLC UCFLFC UCFL4FD UCFLFD UCFLD UCFLFD UCFL FL UC.... UCFLC UCFLD /. UCFL- UCFL- UCFL- UCFL UCFL- UCFLX- UCFLX UCFLX- FL FLX UC- UC- UC- UC UC- UCX- UCX UCX UCFLC UCFLXC UCFLD UCFLXD 4. / /.. UCFLFC UCFLFD UCFL FL UC..4.. UCFLC UCFLD 4. UCFL-4 UCFL- UCFL UCFLX-4 UCFLX UCFL-4 UCFL UCFL- UCFL- UCFL- UCFL UCFLX- UCFLX- UCFLX FL FLX FL FL FLX UC-4 UC- UC UCX-4 UCX UC-4 UC UC- UC- UC- UC UCX- UCX- UCX UCFLC UCFLXC UCFLC UCFLXC UCFLD UCFLXD UCFLD UCFLXD... /....4 UCFLFC UCFLC UCFLFC UCFLFD UCFLD UCFLFD. s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UCFLJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available / /

131 -olt Flange Units UCFL Cylindrical bore (with set screws) d (4) ~ () With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X FL4~FL FLX~FLX FL~FL ±.. FL~FL FL~FL4 ±. -φn L Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FL4~FL FLX~FLX FL~FL ±. FL~FL4 ±. Forms and dimensions of Lc of FL4JE and FLJE (housing with cast iron cover) are shown below. J H L c FL4JE Lc = FLJE Lc = haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch d H L J N kg Cr Cr f s kg c kg 4 / / / / / / / 4 / 4 / / / / / 4 / / / / / 44 / / 4 / 4 4 / 4 / / / / / / / /.4. /. /.4 /.. /. / M M M M M M M M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X, ~4 M M M M M M M UCFL- UCFL UCFL- UCFL- UCFL UCFL- UCFLX- UCFLX UCFLX- FL FL FLX UC- UC UC- UC- UC UC- UCX- UCX UCX UCFLC UCFLXC UCFLD UCFLXD 4 /.. UCFLC UCFLFC UCFLD UCFLFD UCFL FL UC UCFLC UCFLD. UCFL- UCFL-4 UCFL UCFL- UCFL- UCFL UCFL- UCFL- UCFL UCFL- UCFL- UCFL UCFL- UCFL-4 UCFL UCFL-4 UCFL UCFL4-44 UCFL4 UCFL4-44 UCFL4 UCFL-4 UCFL UCFL-4 UCFL-4 UCFL UCFL-4 UCFL- UCFL FL FL FL FL FL FL FL4 FL4 FL FL FL UC- UC-4 UC UC- UC- UC UC- UC- UC UC- UC- UC UC- UC-4 UC UC-4 UC UC4-44 UC4 UC4-44 UC4 UC-4 UC UC-4 UC-4 UC UC-4 UC- UC UCFLC UCFLC UCFLC UCFL4C UCFLC UCFLC UCFLD UCFLD UCFLD UCFL4D UCFLD UCFLD / UCFLFC UCFLC UCFLFC UCFLC UCFLFC UCFLC UCFL4FC UCFL4C UCFLFC UCFLC UCFLFC UCFLFD UCFLD UCFLFD UCFLD UCFLFD UCFLD UCFL4FD UCFL4D UCFLFD UCFLD UCFLFD UCFL FL UC UCFLC UCFLD 4. UCFL- UCFL FL UC- UC UCFLC UCFLD.. UCFLFC UCFLFD UCFL FL UC... UCFLC UCFLD 4. UCFL- UCFL FL UC- UC UCFLC UCFLD. 4. UCFLFC UCFLFD s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UCFLJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available. / / / / 4 / 4 / 4 4 /

132 -olt Flange Units UCFL Cylindrical bore (with set screws) d () ~ With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X FL4~FL FLX~FLX FL~FL ±.. FL~FL FL~FL4 ±. -φn L Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FL4~FL FLX~FLX FL~FL ±. FL~FL4 ±. Forms and dimensions of Lc of FL4JE and FLJE (housing with cast iron cover) are shown below. J H L c FL4JE Lc = FLJE Lc = haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch d H L J N kg Cr Cr f s kg c kg / 4 / 4 / 44 4 / / 4 / / 4 / / / M M M M M4 Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X, ~4 UCFL- UCFL FL UC- UC.. 4. UCFLC UCFLD UCFL FL UC 4.. UCFLC UCFLD 4. UCFL UCFL- UCFL-4 FL UC UC- UC UCFL FL UC.. UCFLC UCFLD 4 /. UCFL4 FL4 UC4.. UCFL4C UCFL4D.4 UCFLC UCFLD. s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UCFLJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available. 4 4 /..

133 -olt Flange Units UCFL-E Cylindrical bore (with set screws) d ~ Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X FLE~FLE ±.. FLE~FLE ±. L -φn Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FLE~FLE ±. J H haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J N Cr Cr f kg / / / / / / / / / / / 4 / 4 / / / / / /.. / 4 / 4 / / / / / 4 / 4 4 / 4 /. / /. 4. / Remarks. In Part No. of unit, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... ~ / / / / / / / / / UCFLE UCFL-E UCFLE UCFL-E UCFLE UCFL4-E UCFL4E UCFL-4E UCFL-E UCFLE UCFL-E UCFL-E UCFLE UCFL-E UCFL-E UCFL-E UCFL-E UCFL-E UCFLE UCFL-E UCFL-4E UCFL-E UCFLE UCFL-E UCFL-E UCFL-E UCFLE UCFL-E UCFL-E UCFLE UCFL-E UCFL-E UCFL-4E UCFLE UCFL-E UCFL-E UCFLE UCFL-E UCFL-E UCFL-4E UCFLE UCFL4-44E UCFL4E UCFL-4E UCFLE UCFL-4E FLE FL4E FLE FLE FLE FLE FLE FLE FLE FLE FLE FL4E FLE UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC- UC- UC-4 UC UC- UC- UC UC- UC- UC-4 UC UC4-44 UC4 UC-4 UC UC s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UCFLEJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available.

134 -olt Flange Units UCFL-E Cylindrical bore (with set screws) d ~ Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X FLE~FLE ±.. FLE~FLE ±. L -φn Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FLE~FLE ±. J H haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J N Cr Cr f kg / Remarks. In Part No. of unit, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... ~ / / UCFL-E UCFLE UCFL-E UCFLE FLE FLE UC- UC UC- UC s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UCFLEJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available.

135 -olt Flange Units NNFL Cylindrical bore (with eccentric locking collar) d ~ Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X NFL4~NFL ±.. NFL ±. L -φn Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns NFL4~NFL ±. J H haft Dia Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J N Cr Cr f kg 4 4 / / / / / / / / 4 / / 4 / 4 / / /. / / 4. Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... / / 4 / 4 / 4 / 4. / 4 / /. / / / / / NNFL NNFL- NNFL NNFL- NNFL NNFL4- NNFL4 NNFL-4 NNFL- NNFL NNFL- NNFL- NNFL NNFL- NNFL- NNFL- NNFL- NNFL- NNFL NNFL- NNFL-4 NNFL- NNFL NNFL- NNFL- NNFL- NNFL NNFL- NNFL- NNFL NNFL- NNFL- NNFL-4 NNFL NNFL- NFL4 NFL NFL NFL NFL NFL NFL NFL N N- N N- N N4- N4 N-4 N- N N- N- N N- N- N- N- N- N N- N-4 N- N N- N- N- N N- N- N N- N- N-4 N N For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Housings of nodular graphite cast iron are also available. 4

136 -olt Flange Units NCFL Cylindrical bore (with concentric locking collar) d ~ Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X FL4~FL ±.. FL~FL ±. L -φn Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FL4~FL ±. J H haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J N d Cr Cr f kg / / / / 4 / / / / 4 / / 4 / / / / 4 4 / 4 / 4 / / 4 4 / / 4 / 4 / / 4 / /. / Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R... ~ / 4. /. /. /. /. /.4 / / M M4 M4 M4 M4 M4 M M M M M M M NCFL4- NCFL4 NCFL-4 NCFL- NCFL NCFL- NCFL- NCFL NCFL- NCFL- FL4 FL FL NC4- NC4 NC-4 NC- NC NC- NC- NC NC- NC NCFL- FL NC NCFL- NCFL NCFL- NCFL-4 NCFL FL FL NC- NC NC- NC-4 NC NCFL- FL NC NCFL- NCFL- NCFL NCFL- NCFL NCFL- FL FL NC- NC- NC NC- NC NC NCFL- FL NC NCFL NCFL- FL NC NC NCFL- FL NC NCFL NCFL- FL NC NC For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated.

137 -olt Flange Units NCFL-E Cylindrical bore (with concentric locking collar) d ~ Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X FL4E~FLE ±.. FLE~FLE ±. L -φn Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FL4E~FLE ±. J H haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J N d Cr Cr f kg / / / / 4 / / / / 4 / / 4 / / / / 4 4 / 4 / 4 / / / / 4 / 4 / / 4 / /. / Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R... ~ / 4. /. /. /. /. /.4 / / / NCFL4-E NCFL4E NCFL-4E NCFL-E NCFLE NCFL-E NCFL-E NCFLE NCFL-E NCFL-E FL4E FLE FLE NC4- NC4 NC-4 NC- NC NC- NC- NC NC- NC / NCFL-E FLE NC / / NCFL-E NCFLE NCFL-E NCFL-4E NCFLE FLE FLE NC- NC NC- NC-4 NC NCFL-E FLE NC NCFL-E NCFL-E NCFLE NCFL-E NCFLE NCFL-E FLE FLE NC- NC- NC NC- NC NC / NCFL-E FLE NC / NCFLE NCFL-E FLE NC NC / NCFL-E FLE NC / NCFLE NCFL-E FLE NC NC For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated.

138 -olt Flange Units UKFL Tapered bore (with adapter) d ~ With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X FL~FL FLX~FLX FL~FL ±.. FL~FL FL~FL4 ±. e L -φn e e Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FL~FL FLX~FLX FL~FL ±. FL~FL4 ±. Forms and dimensions of Lc of FLJE (housing with cast iron cover) are shown below. J H L c FLJE Lc = haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch de d H L J N kg Cr Cr f s kg c kg (min.) / / / HEX. UKFL FL UK 4... M4 HX. UKFLC UKFLD 4.. UKFLFC UKFLFD 4 /. / / 4 4 / / HEX. UKFLX FLX UKX M HX. UKFLXC UKFLXD HEX. UKFL FL UK.... M HX. UKFLC UKFLD 4.4 / 4 4 / HX. UKFLC UKFLD 44. UKFL FL UK.... UKFLFC UKFLFD. 4. M4 HEX. / HX. UKFLXC UKFLXD 4 UKFLX FLX UKX..4. / M4 HEX. 4 HX. UKFLC UKFLD UKFL FL UK... /. 4 4 M HEX. / / / HX. UKFL FL UK M4 HX. UKFLC UKFLD 4 /. UKFLFC UKFLFD. 4 4 / / HX. UKFLX FLX UKX M4 HX. UKFLXC UKFLXD. /. / / HX. UKFL FL UK M HX. UKFLC UKFLD 4.4 HEX. UKFL FL UK HX / / / / 4 / 4 / / / 4 / 4 / 4 44 / / 4 / / / 4 4 / 4 / 4 / 4 4. / / / 4 / 4 / 4 Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X, ~4 /. 4 / / / 4 / 4 / / 4 M4 M4 M M M4 M M M M M M UKFLX FLX UKX UKFL FL UK UKFL FL UK UKFLX FLX UKX UKFL FL UK UKFL FL UK UKFLX FLX UKX UKFL FL UK UKFL FL UK UKFL FL UK HX HEX HX HX HEX HX HX HEX HX HEX HX HEX HX HEX HX HEX HX HEX HX HX HX HEX HX HX HEX UKFLC UKFLXC UKFLC UKFLXC UKFLC UKFLXC UKFLC UKFLD UKFLXD UKFLD UKFLXD UKFLD UKFLXD UKFLD... 4 / / UKFLFC UKFLC UKFLFC UKFLC UKFLFC UKFLC UKFLFC UKFLC UKFLFD UKFLD UKFLFD UKFLD UKFLFD UKFLD UKFLFD UKFLD. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKFLJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UKFLJL + HX, UKL + HX). For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Housings of nodular graphite cast iron are also available / /

139 -olt Flange Units UKFL Tapered bore (with adapter) d ~ With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X FL~FL FLX~FLX FL~FL ±.. FL~FL FL~FL4 ±. e L -φn e e Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FL~FL FLX~FLX FL~FL ±. FL~FL4 ±. Forms and dimensions of Lc of FLJE (housing with cast iron cover) are shown below. J H L c FLJE Lc = haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch de d H L J N kg Cr Cr f s kg c kg (min.) / HX 4. UKFL FL UK M HX 4. UKFLC UKFLD. 4. UKFLFC UKFLFD 4. / / HX. UKFL FL UK.... M HX. UKFLC UKFLD. / / HEX. UKFL FL UK HX UKFLC UKFLD M /. UKFLFC UKFLFD /. HX. HEX. / / UKFL FL UK HX.... UKFLC UKFLD 4 4. M /. HX. / / HEX. UKFL FL UK M HX. UKFLC UKFLD.. UKFLFC UKFLFD. / / HEX.4 UKFL FL UK... M HX.4 UKFLC UKFLD 4 /. / HEX. UKFL FL UK M HX. UKFLC UKFLD.. UKFLFC UKFLFD 4 /.4 / / HEX. UKFL FL UK... M HX. UKFLC UKFLD 4. 4 HX. UKFLC UKFLD. UKFL FL UK UKFLFC UKFLFD M HEX. 4 / / 4 HX. UKFLC UKFLD 4 UKFL FL UK M HEX. / 4 / / / / / 4 / 4 4 / / 4 / /. 4 4 / 4. / M M M M M M4 Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X, ~4 UKFL FL UK HX UKFLC UKFLD. 4. UKFLFC UKFLFD 4 /. UKFL FL UK HX. 4. UKFLC UKFLD 4 /. UKFL FL UK UKFL FL UK UKFL FL UK HEX HX HEX HX HX HEX UKFLC UKFLC UKFLC UKFLD UKFLD UKFLD UKFL4 FL4 UK4 H4.. UKFL4C UKFL4D.. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKFLJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UKFLJL + HX, UKL + HX). For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Housings of nodular graphite cast iron are also available /...

140 djustable -olt Flange Units UCF Cylindrical bore (with set screws) d ~ H Variations of tolerance of distance from mounting surface to center of spherical bore (s) Housing No. s F4~F ±. F ±. L L N N φn Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4~F ±. J haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J N N N L Cr Cr f kg 4 4 / / / / / / / / 4 4 / 4 / / / / / 4 / / 4 / 4 / / 4 / / / 4 / 4 / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... 4 / / / 4 4 / / 4 / 4 / 4 / / / 4 44 /. / / M M M / M / M M4 M4 M4 UCF UCF- UCF UCF- UCF UCF4- UCF4 UCF-4 UCF- UCF UCF- UCF- UCF UCF- UCF- UCF- UCF- UCF- UCF UCF- UCF-4 UCF- UCF UCF- UCF- UCF- UCF UCF- UCF- UCF UCF- UCF- UCF-4 UCF UCF- F4 F F F F F F F UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC- UC- UC-4 UC UC s for triple seal type product (from to are the double seal type products), suffix code L (or L) follows Part No. of unit or bearing. (Example of Part No. : UCFJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Tapered bore (with adapter) type products are also available. (Example of Part No. : UKFJ + HX, UK + HX) 4

141 -olt Flange Units UCF Cylindrical bore (with set screws) d ~ L Variations of tolerance of distance from mounting surface to center of spherical bore (s), variations of tolerance of distance between centers of bolt holes (Js, Js), variations of tolerance of distance between both grooves (Hs) Housing No. s Js Js Hs F4~F ±. H H J H -φn Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns F4~F ±. J L haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d H L J J N H H L Cr Cr f kg 4 4 / / / / / / / 4 4 / / / / / 4 / 4 / 4. / / /.. / 4 4 / 4 4 / / 4 / 4 / / / / / 4 / / / / / / / M / M / M / M M M UCF UCF- UCF UCF- UCF UCF4- UCF4 UCF-4 UCF- UCF UCF- UCF- UCF UCF- UCF- UCF- UCF- UCF- UCF UCF- UCF-4 UCF- UCF UCF- UCF- UCF- UCF UCF- UCF- UCF UCF- Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fitting is --UNF.. s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows Part No. of unit or bearing. (Example of Part No. : UCFJL, UCL) /....4 M F4 F F F F F F UC.4 UC- UC. UC-... UC. UC4- UC4. UC-4 UC- UC UC- UC- UC UC-.... UC- UC- UC- UC UC UC- UC-4 UC UC UC- UC- UC UC UC- UC- UC UC- 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Tapered bore (with adapter) type products are also available. (Example of Part No. : UKFJ + HX, UK + HX)

142 Narrow Inner Ring earing -olt Flange Units FL-RKP Cylindrical bore (with set screws) d ~ FL-FP Cylindrical bore (with eccentric locking collar) -φn -φn Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X FL4~FL ±.. FL ±. L L Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FL4~FL ±. J H J H FL-RKP FL-FP FL-RKP FL-FP haft Dia. Dimensions olt Unit earing Unit earing Housing asic Factor Mass inch inch ize No. No. No. No. No. Load Ratings kn kg inch FL-RKP FL-FP Cr Cr f FL-RKP FL-FP d H L J N 4 / /.4... FL4-RKP 4-RKP FL4-FP 4-FP FL M FL4RKP 4RKP FL4FP 4FP FL-4RKP -4RKP FL-4FP -4FP / / /.... FL-RKP -RKP FL-FP -FP FL M4 FL-RKP -RKP FL-FP -FP FLRKP RKP FLFP FP 4 4 / / / / / / / / 4 / 4 / / 4 / / 4 Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R... / 4 / M4 M4 M4 M M M FL-RKP FL-RKP FL-RKP FLRKP FL-RKP FL-RKP FL-RKP FLRKP FL-4RKP FLRKP -RKP -RKP -RKP RKP -RKP -RKP -RKP RKP -4RKP RKP FL-FP FL-FP FL-FP FLFP FL-FP FL-FP FL-FP FL-FP FLFP FL-4FP FL-FP FLFP FL-FP FL-FP FL-FP FLFP FL-FP FL-FP FLFP FL-FP FL-4FP FL-FP FLFP -FP -FP -FP FP -FP -FP -FP -FP FP -4FP -FP FP -FP -FP -FP FP -FP -FP FP -FP -4FP -FP FP FL..... FL..4. FL For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Housings of nodular graphite cast iron are also available FL FL FL

143 Light -olt Flange Units TFD-H4RKP Cylindrical bore (with set screws) d ~ TFD-FH4P Cylindrical bore (with eccentric locking collar) N N N N H H H J H J L L TFD-H4RKP TFD-FH4P TFD-H4RKP TFD-FH4P haft Dia. Dimensions olt Unit earing Unit earing Housing asic Factor Mass inch inch ize No. No. No. No. No. Load Ratings kn kg inch TFD TFD TFD TFD Cr Cr f TFD TFD d H L J N H TFDH4RKP RKP TFDFH4P FP / / TFD-H4RKP -RKP TFD-FH4P -FP.... TFDH4RKP RKP TFDFH4P FP TFDH TFD-H4RKP -RKP TFD-FH4P -FP TFDH4RKP RKP TFDFH4P FP / / / / /.. 4 /. 4 / /. /.4. /. / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fitting is --UNF.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. /.. / / / TFD4-H4RKP TFD4H4RKP 4-RKP 4RKP TFD-4H4RKP -4RKP TFD-H4RKP -RKP TFDH4RKP RKP TFD-H4RKP -RKP TFD-H4RKP -RKP TFDH4RKP RKP TFD-H4RKP -RKP TFD-H4RKP -RKP TFD-H4RKP -RKP TFD-H4RKP -RKP TFDH4RKP RKP TFD-H4RKP -RKP TFD4-FH4P TFD4FH4P TFD-4FH4P TFD-FH4P TFDFH4P TFD-FH4P TFD-FH4P TFDFH4P TFD-FH4P TFD-FH4P TFD-FH4P TFD-FH4P TFD-FH4P TFDFH4P TFD-FH4P 4-FP 4FP TFD4H FP -FP FP TFDH FP -FP FP -FP TFDH FP -FP -FP -FP TFDH FP -FP

144 Light -olt Flange Units LF Cylindrical bore (with set screws) d ~ LF Cylindrical bore (with eccentric locking collar) Variations of tolerance of distance from mounting surface to center of spherical bore (s) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. s Js LF~LF ±. ±. L -φn Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns LF~LF ±. LF LF LF J H haft Dia. Dimensions olt Unit earing Unit earing Housing asic Factor Mass inch inch ize No. No. No. No. No. Load Ratings kn kg inch LF LF Cr Cr f LF LF d H L J N LF LF / / /... LF- - LF- - LF LF LF M LF- - LF- - LF LF / / / / 4 / 4 / 4. / 4 /. /. / / / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). llowable load to housing in radial direction is approximately half of basic load rating of bearing, Cr (when safety factor is 4).. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit /. 4 / / / M / M M M LF4- LF4 LF-4 LF- LF LF- LF- LF LF- LF- LF- LF- LF LF LF4- LF4 LF-4 LF- LF LF- LF- LF LF- LF- LF- LF- LF- LF LF LF LF LF LF..... LF..4...

145 Compact -olt Flange Units UFL Cylindrical bore (with set screws) d ~ L -φn With Through Type Cover With One ide ealed Cover Variations of tolerance of distance from mounting surface to center of spherical bore (s) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. s Js FL ±. ±. FL~FL Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FL ±. FL~FL J H haft Dia. Dimensions olt tandard asic Factor With Rubber Coated Cover inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d H L J N kg Cr Cr f s kg 4 4 / 4 / 4. / / / / 4. / /. / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. No. M4 M M M M / M / M M UFL FL U....4 UFL FL U UFLC UFLD. /. UFL FL U...4. UFLC UFLD. /. UFL FL U.... UFLC UFLD. UFL FL U UFLC UFLD. /. UFL4 FL4 U UFL4C UFL4D /. UFL FL U UFLC UFLD. UFL FL U UFLC UFLD. 4

146 Corrosion Resistant eries -olt Flange Units UCFL-H Cylindrical bore (with set screws) d ~ With Pressed tainless teel Cover Variations of tolerance of distance from mounting surface to center of spherical bore (s) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. s Js FLH~FLH ±. ±. L -φn Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FLH~FLH ±. J H haft Dia. Dimensions olt tandard asic Factor With Pressed tainless teel Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d H L J N kg Cr Cr f s kg / / / / / / / / / 4 / / / 4 / 4 / / 4. 4 / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. / / 4 4 /. / / M M M4 M4 M4 M4 M M UCFLXH UCFL-XH UCFLXH UCFL-XH UCFLXH UCFL4-H UCFL4H UCFL-4H UCFL-H UCFLH UCFL-H UCFL-H UCFLH UCFL-H UCFL-H UCFL-H UCFL-H UCFL-H UCFLH UCFL-H UCFL-4H UCFL-H UCFLH UCFL-H UCFL-H UCFL-H UCFLH UCFL-H UCFL-H UCFLH UCFL-H FLH FL4H FLH FLH FLH FLH FLH FLH UCX UC-X UCX UC-X UCX UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC UCFL4HC UCFLHC UCFLHC UCFLHC UCFLHC UCFLHC UCFLHC UCFL4HD UCFLHD UCFLHD UCFLHD UCFLHD UCFLHD UCFLHD / / /

147 Corrosion Resistant eries -olt Flange Units UCFL-EH Cylindrical bore (with set screws) d ~ With Pressed tainless teel Cover Variations of tolerance of distance from mounting surface to center of spherical bore (s) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. s Js FLEH~FLEH ±. ±. L -φn Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FLEH~FLEH ±. J H haft Dia. Dimensions olt tandard asic Factor With Pressed tainless teel Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d H L J N kg Cr Cr f s kg / / / / / / / / / 4 / / / 4 / 4 / / 4. 4 / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. / / 4 4 /. / / / / / / UCFLXEH UCFL-XEH UCFLXEH UCFL-XEH UCFLXEH UCFL4-EH UCFL4EH UCFL-4EH UCFL-EH UCFLEH UCFL-EH UCFL-EH UCFLEH UCFL-EH UCFL-EH UCFL-EH UCFL-EH UCFL-EH UCFLEH UCFL-EH UCFL-4EH UCFL-EH UCFLEH UCFL-EH UCFL-EH UCFL-EH UCFLEH UCFL-EH UCFL-EH UCFLEH UCFL-EH FLEH FL4EH FLEH FLEH FLEH FLEH FLEH FLEH UCX UC-X UCX UC-X UCX UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC UCFL4EHC UCFLEHC UCFLEHC UCFLEHC UCFLEHC UCFLEHC UCFLEHC UCFL4EHD UCFLEHD UCFLEHD UCFLEHD UCFLEHD UCFLEHD UCFLEHD / / /

148 Corrosion Resistant eries -olt Flange Units UFL- Cylindrical bore (with set screws) d ~ With Through Type Cover With One ide ealed Cover Variations of tolerance of distance from mounting surface to center of spherical bore (s) and variations of tolerance of distance between centers of bolt holes (Js) Housing No. s Js FL~FL ±. ±. L -φn Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FL~FL ±. J H haft Dia. Dimensions olt tandard asic Factor With Rubber Coated Cover inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d H L J N kg Cr Cr f s kg / / /. / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. M M M M / M / M M UFL FL U.... UFLC UFLD. /. UFL FL U UFLC UFLD. /. UFL FL U UFLC UFLD. UFL FL U UFLC UFLD. /. UFL4 FL4 U UFL4C UFL4D /. UFL FL U UFLC UFLD. UFL FL U UFLC UFLD.

149 Corrosion Resistant eries -olt Flange Units UCVFL- Cylindrical bore (with set screws) d ~ 4 Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X VFL4~VFL ±.. -φn L J H haft Dia. Dimensions olt tandard asic Factor With Plastic Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d H L J N kg Cr Cr f s kg 4 4 / / / / / / / 4 4 / / /.. / / / / 4.4. / / M M M / M M UCVFL4- UCVFL4 UCVFL-4 UCVFL- UCVFL UCVFL- UCVFL- UCVFL UCVFL- UCVFL- UCVFL- UCVFL- UCVFL- UCVFL UCVFL- UCVFL-4 UCVFL- UCVFL Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. VFL4 VFL VFL VFL VFL UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UCVFL4-C UCVFL4C UCVFL-4C UCVFL-C UCVFLC UCVFL-C UCVFL-C UCVFLC UCVFL-C UCVFL-C UCVFL-C UCVFL-C UCVFL-C UCVFLC UCVFL-C UCVFL-4C UCVFL-C UCVFLC UCVFL4-D UCVFL4D UCVFL-4D UCVFL-D UCVFLD UCVFL-D UCVFL-D UCVFLD UCVFL-D UCVFL-D UCVFL-D UCVFL-D UCVFL-D UCVFLD UCVFL-D UCVFL-4D UCVFL-D UCVFLED

150 Corrosion Resistant eries -olt Flange Units UCVFL-E Cylindrical bore (with set screws) d ~ 4 Variations of tolerance of distance from mounting surface to center of spherical bore (s) and tolerance of position of bolt hole (X) Housing No. s X VFL4E~VFLE ±.. -φn L J H haft Dia. Dimensions olt tandard asic Factor With Plastic Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d H L J N kg Cr Cr f s kg 4 4 / / / / / / / 4 4 / / /.. / / / / 4.4. / / M / M / M M M UCVFL4-E UCVFL4E UCVFL-4E UCVFL-E UCVFLE UCVFL-E UCVFL-E UCVFLE UCVFL-E UCVFL-E UCVFL-E UCVFL-E UCVFL-E UCVFLE UCVFL-E UCVFL-4E UCVFL-E UCVFLE Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. VFL4E VFLE VFLE VFLE VFLE UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UCVFL4-EC UCVFL4EC UCVFL-4EC UCVFL-EC UCVFLEC UCVFL-EC UCVFL-EC UCVFLEC UCVFL-EC UCVFL-EC UCVFL-EC UCVFL-EC UCVFL-EC UCVFLEC UCVFL-EC UCVFL-4EC UCVFL-EC UCVFLEC UCVFL4-ED UCVFL4ED UCVFL-4ED UCVFL-ED UCVFLED UCVFL-ED UCVFL-ED UCVFLED UCVFL-ED UCVFL-ED UCVFL-ED UCVFL-ED UCVFL-ED UCVFLED UCVFL-ED UCVFL-4ED UCVFL-ED UCVFLED

151 Corrosion Resistant eries -olt Flange Units UCVF-E Cylindrical bore (with set screws) d ~ L H H J -φn J haft Dia. Dimensions olt tandard asic Factor With Plastic Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d H L J J N H kg Cr Cr f s kg 4 / / / / 4 / / / 4. / 4 /.4. /.4 / / M M M M UCVF4-E UCVF4E UCVF-4E UCVF-E UCVFE UCVF-E UCVF-E UCVFE UCVF-E UCVF-E UCVF-E UCVF-E UCVF-E UCVFE UCVF-E Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. VF4E VFE VFE VFE UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC UCVF4-EC UCVF4EC UCVF-4EC UCVF-EC UCVFEC UCVF-EC UCVF-EC UCVFEC UCVF-EC UCVF-EC UCVF-EC UCVF-EC UCVF-EC UCVFEC UCVF-EC UCVF4-ED UCVF4ED UCVF-4ED UCVF-ED UCVFED UCVF-ED UCVF-ED UCVFCD UCVF-ED UCVF-ED UCVF-ED UCVF-ED UCVF-ED UCVFED UCVF-ED /.4..

152 4-olt Flange Cartridge Units UCFC Cylindrical bore (with set screws) d ~ φh L J 4-φN With Pressed teel Cover φh With Cast Iron Cover φh Variations of tolerance of spigot joint outside diameter (Hs), variations of tolerance of distance from mounting surface to center of spherical bore (s), tolerance of position of bolt hole (X), and tolerance of circumferential runout of spigot joint (Y) Housing No. Hs s X Y FC4~FC FCX.4 ±... FC~FC FCX~FCX.4 FC~FC FCX~FCX.. ±. FC FCX~FCX FCX..4 Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FC4~FC FCX~FCX ±. 4 J 4 4 C haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch d L H J J N 4 kg Cr Cr f s kg c kg 4 4 / / / / / / / / / 4 / / / / / / /.. /. 4. / /. / / 4. Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X -R... ~, X~X / / / / /. / / /. /... /.4 / / M M / M M M / M M / M M M4 / M M4 / M UCFC UCFC- UCFC UCFC- UCFC UCFC4- UCFC4 UCFC-4 UCFC- UCFC UCFC- UCFCX UCFCX- UCFC- UCFC UCFC- UCFC- UCFCX UCFCX- UCFCX- UCFC- UCFC- UCFC- UCFC UCFC- UCFCX- UCFCX UCFCX- UCFC-4 UCFC- UCFC UCFCX-4 UCFCX UCFC- UCFC- UCFC- UCFC UCFCX- UCFCX- UCFCX UCFC- UCFC- UCFC UCFC- UCFCX- UCFCX UCFCX- FC4 FC FCX FC FCX FC FCX FC FCX FC FCX FC FCX UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UCX UCX- UC- UC UC- UC- UCX UCX- UCX- UC- UC- UC- UC UC- UCX- UCX UCX- UC-4 UC- UC UCX-4 UCX UC- UC- UC- UC UCX- UCX- UCX UC- UC- UC UC- UCX- UCX UCX UCFCC UCFCC UCFCC UCFC4C UCFCC UCFCXC UCFCC UCFCXC UCFCC UCFCXC UCFCC UCFCXC UCFCC UCFCXC UCFCC UCFCXC UCFCD UCFCD UCFCD UCFC4D UCFCD UCFCXD UCFCD UCFCXD UCFCD UCFCXD UCFCD UCFCXD UCFCD UCFCXD UCFCD UCFCXD / / UCFC4FC UCFCFC UCFCFC UCFCFC UCFCFC UCFCFC UCFCFC UCFC4FD UCFCFD UCFCFD UCFCFD UCFCFD UCFCFD UCFCFD. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCFCJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available /

153 4-olt Flange Cartridge Units UCFC Cylindrical bore (with set screws) d ~ φh L J 4-φN With Pressed teel Cover φh With Cast Iron Cover φh Variations of tolerance of spigot joint outside diameter (Hs), variations of tolerance of distance from mounting surface to center of spherical bore (s), tolerance of position of bolt hole (X), and tolerance of circumferential runout of spigot joint (Y) Housing No. Hs s X Y FC4~FC FCX.4 ±... FC~FC FCX~FCX.4 FC~FC FCX~FCX.. ±. FC FCX~FCX FCX..4 Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FC4~FC FCX~FCX ±. 4 J 4 4 C haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch d L H J J N 4 kg Cr Cr f s kg c kg / / / / / 4 / 4 / / / / /.4. / 4. / 4 / / / / / 4 / / / / / /. /.4.4 /.... /..... / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X -R... ~, X~X. 4. M M4 M M4 M M4 M M M M M M M M M M M UCFC- UCFC-4 UCFC UCFC- UCFCX UCFCX- UCFCX- UCFC- UCFC UCFC- UCFC- UCFCX UCFCX- UCFC-4 UCFC UCFCX-4 UCFCX UCFC4-44 UCFC4 UCFCX4-44 UCFCX4 UCFC-4 UCFC UCFC-4 UCFCX-4 UCFCX UCFCX-4 UCFC- UCFC FC FCX FC FCX FC FCX FC4 FCX4 FC FCX FC UC- UC-4 UC UC- UCX UCX- UCX- UC- UC UC- UC- UCX UCX- UC-4 UC UCX-4 UCX UC4-44 UC4 UCX4-44 UCX4 UC-4 UC UC-4 UCX-4 UCX UCX-4 UC- UC UCFCC UCFCXC UCFCC UCFCXC UCFCC UCFCXC UCFC4C UCFCX4C UCFCC UCFCXC UCFCC UCFCD UCFCXD UCFCD UCFCXD UCFCD UCFCXD UCFC4D UCFCX4D UCFCD UCFCXD UCFCD / UCFCFC UCFCFC UCFCFC UCFC4FC UCFCFC UCFCFC UCFCFD UCFCFD UCFCFD UCFC4FD UCFCFD UCFCFD UCFCX FCX UCX UCFCXC UCFCXD.. UCFC- UCFC UCFCX UCFCX- UCFC- UCFC FC FCX FC UC- UC UCX UCX- UC- UC UCFCC UCFCXC UCFCC UCFCD UCFCXD UCFCD 4... / /... UCFCFC UCFCFC UCFCFD UCFCFD UCFCX FCX UCX UCFCXC UCFCXC.4 UCFCX UCFCX- UCFCX-4 FCX UCX UCX- UCX UCFCXC UCFCXD. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCFCJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available.. 4 / 4 /

154 4-olt Flange Cartridge Units UCFCX-E Cylindrical bore (with set screws) d ~ φh L J 4-φN Variations of tolerance of spigot joint outside diameter (Hs), variations of tolerance of distance from mounting surface to center of spherical bore (s), tolerance of position of bolt hole (X), and tolerance of circumferential runout of spigot joint (Y) Housing No. Hs s X Y FCXE.4 ±... FCXE~FCXE.4 FCXE~FCXE.. ±. FCXE~FCXE. FCXE.4 Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FCXE~FCXE ±. 4 J haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d L H J J N 4 Cr Cr f kg / 4 4 / 4 / / / 4 4 / / / / / 4. / / / 4 / / / / 4. / /. / /.4 /.. /... / Remarks. In Part No. of unit, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... X~X -R... X~X / M M M M / M / M M4 M4 M M M M M M UCFCXE UCFCX-E UCFCXE UCFCX-E UCFCX-E UCFCX-E UCFCXE UCFCX-E UCFCX-4E UCFCXE UCFCX-E UCFCX-E UCFCXE UCFCX-E UCFCXE UCFCX-E UCFCXE UCFCX-E UCFCX-4E UCFCXE UCFCX4-44E UCFCX4E UCFCX-4E UCFCXE UCFCX-4E FCXE FCXE FCXE FCXE FCXE FCXE FCXE FCXE FCX4E FCXE UCX UCX- UCX UCX- UCX- UCX- UCX UCX- UCX-4 UCX UCX- UCX- UCX UCX- UCX UCX- UCX UCX- UCX-4 UCX UCX4-44 UCX4 UCX-4 UCX UCX UCFCXE FCXE UCX UCFCXE UCFCX-E FCXE UCX UCX UCFCXE FCXE UCX UCFCXE UCFCX-E UCFCX-4E FCXE UCX UCX- UCX s for the triple seal type product, suffix code L follows the Part No. of unit or bearing. (Example of Part No. : UCFCXEL, UCXL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available.

155 4-olt Flange Cartridge Units UCFCF Cylindrical bore (with set screws) d ~ φh L J 4-φN Variations of tolerance of spigot joint outside diameter (Hs), variations of tolerance of distance from mounting surface to center of spherical bore (s), tolerance of position of bolt hole (X), and tolerance of circumferential runout of spigot joint (Y) Housing No. Hs s X Y FCF~FCF.4 ±... FCF~FCF.4 FCF. ±.. Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FCF~FCF ±. 4 J haft Dia. Dimensions olt tandard asic Factor inch inch ize Unit Housing earing Mass Load Ratings inch No. No. No. kn d L H J J N 4 kg Cr Cr f 4 4 / / / / / / / / / /.. Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... / / / M / M / M / M M M M4 UCFCF-4 UCFCF- UCFCF UCFCF- UCFCF- UCFCF UCFCF- UCFCF- UCFCF- UCFCF- UCFCF- UCFCF UCFCF- UCFCF-4 UCFCF- UCFCF UCFCF- UCFCF- UCFCF- UCFCF UCFCF- UCFCF- UCFCF UCFCF- UCFCF- UCFCF-4 UCFCF UCFCF- FCF FCF FCF FCF FCF FCF FCF UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC- UC- UC-4 UC UC s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCFCFJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available. 4

156 4-olt Flange Cartridge Units NCFC Cylindrical bore (with concentric locking collar) d ~ φh L J 4-φN Variations of tolerance of spigot joint outside diameter (Hs), variations of tolerance of distance from mounting surface to center of spherical bore (s), tolerance of position of bolt hole (X), and tolerance of circumferential runout of spigot joint (Y) Housing No. Hs s X Y FC4~FC.4 ±... FC~FC.4 FC~FC. ±.. Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FC4~FC ±. 4 J haft Dia. Dimensions olt Unit Housing earing asic Factor Mass inch inch ize No. No. No. Load Ratings inch kn d L H J J N 4 d Cr Cr f kg 4 4 / / / 4 4 / / / 4 / / / / / / / / / /... /. / /. / / / / 4 / / / /... / /. / Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R... ~ / 4. /. /. /. /. /.4 / / M M M / M / M / M M4 M4 M4 M M M M NCFC4- NCFC4 NCFC-4 NCFC- NCFC NCFC- NCFC- NCFC NCFC- NCFC- FC4 FC FC NC4- NC4 NC-4 NC- NC NC- NC- NC NC- NC NCFC- FC NC NCFC- NCFC NCFC- NCFC-4 NCFC FC FC NC- NC NC- NC-4 NC NCFC- FC NC NCFC- NCFC- NCFC NCFC- NCFC NCFC- FC FC NC- NC- NC NC- NC NC NCFC- FC NC NCFC NCFC- FC NC NC NCFC- FC NC NCFC NCFC- FC NC NC For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated.

157 4-olt Flange Cartridge Units UKFC Tapered bore (with adapter) d ~ φh L J 4-φN With Pressed teel Cover φh With Cast Iron Cover φh Variations of tolerance of spigot joint outside diameter (Hs), variations of tolerance of distance from mounting surface to center of spherical bore (s), tolerance of position of bolt hole (X), and tolerance of circumferential runout of spigot joint (Y) Housing No. Hs s X Y FC~FC FCX.4 ±... FC~FC FCX~FCX.4 FC~FC FCX~FCX.. ±. FC FCX~FCX FCX..4 Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FC4~FC FCX~FCX ±. 4 J 4 4 C haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch d L H J J N 4 kg Cr Cr f s kg c kg / 4 / / 4 / / / / 4. /. 4. / / / 4. / / / / / 4 4 / /. / / / /... /. /. / /. 4 / 4 / 4 / 4 / 4 / / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X -R... ~, X~X / / 4 / /. 4 / / M / M M M / M M / M M M4 / M M4 / M M M4 M M4 M M4 M M UKFC FC UK UKFCX FCX UKX UKFC FC UK UKFCX FCX UKX UKFC FC UK UKFCX FCX UKX UKFC FC UK UKFCX FCX UKX UKFC FC UK UKFCX FCX UKX UKFC FC UK UKFCX FCX UKX UKFC FC UK UKFCX FCX UKX UKFC FC UK UKFCX FCX UKX UKFC FC UK UKFCX FCX UKX UKFC FC UK UKFCX FCX UKX HEX HX HEX HX HX HEX HX HEX HX HX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HEX HX HEX HX HX HX HEX HX HX HEX HX HX HX HX HEX HX HX HEX HX HX HEX HX HEX HX UKFCC UKFCXC UKFCC UKFCXC UKFCC UKFCXC UKFCC UKFCXC UKFCC UKFCXC UKFCC UKFCXC UKFCC UKFCXC UKFCC UKFCXC UKFCC UKFCXC UKFCC UKFCXC UKFCD UKFCXD UKFCD UKFCXD UKFCD UKFCXD UKFCD UKFCXD UKFCD UKFCXD UKFCD UKFCXD UKFCD UKFCXD UKFCD UKFCXD UKFCD UKFCXD UKFCD UKFCXD / / / UKFCFC UKFCFC UKFCFC UKFCFC UKFCFC UKFCFC UKFCFC UKFCFC UKFCFC UKFCFC UKFCFD UKFCFD UKFCFD UKFCFD UKFCFD UKFCFD UKFCFD UKFCFD UKFCFD UKFCFD. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKFCJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UKFCJL + HX, UKL + HX). For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Housings of nodular graphite cast iron are also available /

158 4-olt Flange Cartridge Units UKFC Tapered bore (with adapter) d ~ φh L J 4-φN With Pressed teel Cover φh With Cast Iron Cover φh Variations of tolerance of spigot joint outside diameter (Hs), variations of tolerance of distance from mounting surface to center of spherical bore (s), tolerance of position of bolt hole (X), and tolerance of circumferential runout of spigot joint (Y) Housing No. Hs s X Y FC~FC FCX.4 ±... FC~FC FCX~FCX.4 FC~FC FCX~FCX.. ±. FC FCX~FCX FCX..4 Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FC4~FC FCX~FCX ±. 4 J 4 4 C haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn Open Type Closed Type inch Open Type Closed Type inch inch d L H J J N 4 kg Cr Cr f s kg c kg / 4 / / / / / 4 4. / /. / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X -R... ~, X~X M M M M M M M UKFC FC UK UKFCX FCX UKX UKFC FC UK UKFCX FCX UKX HEX HX HEX HX HX HEX HX HEX UKFCC UKFCXC UKFCC UKFCXC UKFCD UKFCXD UKFCD UKFCXD / / UKFCFC UKFCFC UKFCFD UKFCFD UKFC FC UK HX UKFCC UKFCD.. UKFCFC UKFCFD 4. UKFCX FCX UKX HX UKFCXC UKFCXD. UKFCX FCX UKX HEX HX UKFCXC UKFCXD. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKFCJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UKFCJL + HX, UKL + HX). For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Housings of nodular graphite cast iron are also available. / 4 /...

159 Narrow Inner Ring earing 4-olt Flange Cartridge Units FC-RKP Cylindrical bore (with set screws) d ~ FC-FP Cylindrical bore (with eccentric locking collar) φh L J 4-φN φh L J 4-φN Variations of tolerance of spigot joint outside diameter (Hs), variations of tolerance of distance from mounting surface to center of spherical bore (s), tolerance of position of bolt hole (X), and tolerance of circumferential runout of spigot joint (Y) Housing No. Hs s X Y FC4~FC.4 ±... FC~FC.4 FC. ±.. FC-RKP FC-FP 4 FC-RKP J 4 FC-FP J Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns FC4~FC ±. haft Dia. Dimensions olt Unit earing Unit earing Housing asic Factor Mass inch inch ize No. No. No. No. No. Load Ratings kn kg inch FC-RKP FC-FP Cr Cr f FC-RKP FC-FP d L J J N H 4 /.44 / /.4... FC4-RKP 4-RKP FC4-FP 4-FP FC M FC4RKP 4RKP FC4FP 4FP FC-4RKP -4RKP FC-4FP -4FP / 4. / /.... FC-RKP -RKP FC-FP -FP FC M FC-RKP -RKP FC-FP -FP FCRKP RKP FCFP FP 4 4 / / / / / / / 4 / 4 / / 4 4 /. / Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R... / / / / / / M / M / M M4 M4 M FC-RKP FC-RKP FC-RKP FCRKP FC-RKP FC-RKP FC-RKP FCRKP FC-4RKP FCRKP -RKP -RKP -RKP RKP -RKP -RKP -RKP RKP -4RKP RKP FC-FP FC-FP FC-FP FCFP FC-FP FC-FP FC-FP FC-FP FCFP FC-4FP FC-FP FCFP FC-FP FC-FP FC-FP FCFP FC-FP FC-FP FCFP FC-FP FC-4FP FC-FP FCFP -FP -FP -FP FP -FP -FP -FP -FP FP -4FP -FP FP -FP -FP -FP FP -FP -FP FP -FP -4FP -FP FP FC..... FC..4. FC For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated FC FC FC

160 Corrosion Resistant eries 4-olt Flange Cartridge Units UCFC-H Cylindrical bore (with set screws) d ~ 4 4-φN Variations of tolerance of spigot joint outside diameter (Hs) Housing No. Hs FC4H~FCH.4 FCH~FCH.4 φh L J φh 4 J 4 haft Dia. Dimensions olt tandard asic Factor With Pressed tainless teel Cover inch inch ize Unit Housing earing Mass Load Ratings Unit No. Dimension Mass No. No. No. kn Open Type Closed Type inch inch d L H J J N 4 kg Cr Cr f s kg 4 / / / / / / 4 4 / / / / / /. /.. / M M M / M UCFC4-H UCFC4H UCFC-4H UCFC-H UCFCH UCFC-H UCFC-H UCFCH UCFC-H UCFC-H UCFC-H UCFC-H UCFC-H UCFCH UCFC-H UCFC-4H UCFC-H UCFCH Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. / / M FC4H FCH FCH FCH FCH UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UCFC4HC UCFCHC UCFCHC UCFCHC UCFCHC UCFC4HD UCFCHD UCFCHD UCFCHD UCFCHD /

161 tamped teel -olt Flange Cartridge Units PF Cylindrical bore (with set screws) d ~ PF Cylindrical bore (with eccentric locking collar) φh H J N N φh Variations of tolerance of distance between centers of bolt holes (Js) Housing No. Js PF~PF ±.4 Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns PF~PF ±. PF PF PF haft Dia Dimensions olt Unit earing Unit earing Housing asic Factor Mass inch inch ize No. No. No. No. No. Load Ratings kn kg inch PF PF Cr Cr f PF PF d H J N H PF PF / / /... PF- - PF- - PF PF M PF- - PF- - PF PF PF /..4. / PF4-4- PF M PF4 4 PF4 4 PF PF-4-4 PF-4-4 /... / PF- - PF M PF PF PF PF- - PF- - PF- - PF- - 4 / / /... PF PF /... M PF- - PF- - PF..... PF- - PF- - PF- - PF- - / 4 / / / /...4 PF- - PF- - PF M PF PF PF / PF- - PF- - Note ) H is the minimum size of the mounting hole. Remark For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. PF

162 tamped teel -olt Flange Units PFL Cylindrical bore (with set screws) d ~ PFL Cylindrical bore (with eccentric locking collar) φh L N N φh Variations of tolerance of distance between centers of bolt holes (Js) Housing No. Js PFL~PFL ±.4 Variations of tolerance of bolt hole diameter (Ns) Housing No. Ns PFL~PFL ±. J H PFL PFL PFL PFL haft Dia Dimensions olt Unit earing Unit earing Housing asic Factor Mass inch inch ize No. No. No. No. No. Load Ratings kn kg inch PFL PFL Cr Cr f PFL PFL d H L J N H PFL PFL / / / /... PFL- - PFL- - PFL PFL M PFL- - PFL- - PFL PFL PFL /..4. / PFL4-4- PFL M PFL4 4 PFL4 4 PFL PFL-4-4 PFL-4-4 /... / PFL- - PFL M PFL PFL PFL PFL- - PFL- - PFL- - PFL- - 4 / / / /... PFL PFL / 4... M PFL- - PFL- - PFL PFL- - PFL- - PFL- - PFL- - / 4 / / / / /...4 PFL- - PFL- - PFL M PFL PFL PFL / PFL- - PFL- - Note ) H is the minimum size of the mounting hole. Remark For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.

163 Take-Up Units UCT Cylindrical bore (with set screws) d ~ (4) L With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T4~T TX~TX T~T +.. T~T TX~TX T~T. T~T +... T4~T.. H H H N φn H H Form and dimensions of Lc of T4JE and TJE (housing with cast iron cover) are shown below. L N L c T4JE Lc = TJE Lc = L L haft Dia. Dimensions tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn inch inch Open Type One ide Open Type One ide d H H H L L L L N N N kg Cr Cr f Closed Type s kg Closed Type c kg / / / / / / / 4 / 4 4 / 4 / 4 / / 4 / / 4 4 / / 4 / / / / / / 4 4 / / 4 / 4 / 4 / 4 / / / / / 4 / / / 4 / / 4 / 4 4 / 4 / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ 44 4 / / 4 / UCT UCT- UCT UCT- UCT UCT4- UCT4 UCT-4 UCT- UCT UCT- UCTX UCTX- UCT UCT- UCT- UCT UCT- UCT- UCTX UCTX- UCTX- T4 T TX T T TX UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UCX UCX- UC UC- UC- UC UC- UC- UCX UCX- UCX UCTC UCTC UCTC UCT4C UCTC UCTXC UCTC UCTXC UCTCD UCTCD UCTCD UCT4CD UCTCD UCTXCD UCTCD UCTXCD / UCT4FC UCTFC UCTC UCTFC UCT4FCD UCTFCD UCTCD UCTFCD UCT T UC.... UCTC UCTCD.4 UCT- UCT- UCT- UCT UCT- UCTX- UCTX UCTX- T TX UC- UC- UC- UC UC- UCX- UCX UCX UCTC UCTXC UCTCD UCTXCD.. UCTFC UCTFCD UCT T UC..4.. UCTC UCTCD. UCT-4 UCT- UCT UCTX-4 UCTX UCT-4 UCT UCT- UCT- UCT- UCT UCTX- UCTX- UCTX T TX T T TX UC-4 UC- UC UCX-4 UCX UC-4 UC UC- UC- UC- UC UCX- UCX- UCX UCTC UCTXC UCTC UCTXC UCTCD UCTXCD UCTCD UCTXCD UCTFC UCTC UCTFC UCTFCD UCTCD UCTFCD. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCTJL, UCL) 4. s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available. / /

164 Take-Up Units UCT Cylindrical bore (with set screws) d (4) ~ () L With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T4~T TX~TX T~T +.. T~T TX~TX T~T. T~T +... T4~T.. H H H N φn H H Form and dimensions of Lc of T4JE and TJE (housing with cast iron cover) are shown below. L N L c T4JE Lc = TJE Lc = L L haft Dia. Dimensions tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn inch inch Open Type One ide Open Type One ide d H H H L L L L N N N kg Cr Cr f Closed Type s kg Closed Type c kg 4 4 / / 4 / / / / / / / / / 4 4 / / / 4 4 / 4 4 / 4 4 / / / / / / / / / / / / / / / / / / 4 / 4 / 4 / / 4 4 / 4 / 4 / / 4 4 / / / / / / / 4 / / / 4 / 4 / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ 4 4 / / UCT- UCT UCT- UCT- UCT UCT- UCTX- UCTX UCTX- T T TX UC- UC UC- UC- UC UC- UCX- UCX UCX UCTC UCTXC UCTCD UCTXCD UCTC UCTFC UCTCD UCTFCD UCT T UC UCTC UCTCD 4. UCT- UCT-4 UCT UCT- UCTX UCTX- UCTX- UCT- UCT UCT- UCT- UCT UCT- UCT- UCTX UCTX- UCT UCT- UCT-4 UCT UCTX-4 UCTX UCT-4 UCT UCT4-44 UCT4 UCTX4-44 UCTX4 UCT4-44 UCT4 UCT-4 UCT UCT-4 UCTX-4 UCTX UCTX-4 T TX T T TX T T TX T T4 TX4 T4 T TX UC- UC-4 UC UC- UCX UCX- UCX- UC- UC UC- UC- UC UC- UC- UCX UCX- UC UC- UC-4 UC UCX-4 UCX UC-4 UC UC4-44 UC4 UCX4-44 UCX4 UC4-44 UC4 UC-4 UC UC-4 UCX-4 UCX UCX UCTC UCTXC UCTC UCTXC UCTC UCTXC UCT4C UCTX4C UCTC UCTXC UCTCD UCTXCD UCTCD UCTXCD UCTCD UCTXCD UCT4CD UCTX4CD UCTCD UCTXCD UCTFC UCTC UCTFC UCTC UCTFC UCTC UCT4FC UCT4C UCTFC UCTFCD UCTCD UCTFCD UCTCD UCTFCD UCTCD UCT4FCD UCT4CD UCTFCD. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCTJL, UCL) 4. s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available / /

165 Take-Up Units UCT Cylindrical bore (with set screws) d () ~ 4 L With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T4~T TX~TX T~T +.. T~T TX~TX T~T. T~T +... T4~T.. H H H N φn H H Form and dimensions of Lc of T4JE and TJE (housing with cast iron cover) are shown below. L N L c T4JE Lc = TJE Lc = L L haft Dia. Dimensions tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch Unit Housing earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. kn inch inch Open Type One ide Open Type One ide d H H H L L L L N N N kg Cr Cr f Closed Type s kg Closed Type c kg / 4 / / / / / / 4 / / / 4 / / 4 4 / / / / 4 4 / / / / 4 4 / 4 / 4 4 / / / / / / / / / / / 4 / / / / / 4 4 / 4 / / / 4 / 4 / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ UCT-4 UCT UCT-4 UCT- UCT T T UC-4 UC UC-4 UC- UC UCTC UCTCD 4. UCTC UCTFC UCTCD UCTFCD UCTX TX UCX UCTXC UCTXCD 4 /. UCT T UC... UCTC UCTCD /. UCT- UCT UCTX UCTX- T TX UC- UC.. UCX. UCX UCTC UCTXC UCTCD UCTXCD 4 / 4.. UCTFC UCTFCD UCT T UC... UCTC UCTCD 4. UCT- UCT T UC- UC.. 4. UCTC UCTCD UCT T UC 4.. UCTC UCTCD. UCT UCT- UCT-4 T UC UC- UC UCT T UC. 4. UCTC UCTCD 4. UCT T UC.. UCTC UCTCD 4. UCT4 T4 UC UCT4C UCT4CD. UCT T UC. 4. UCTC UCTCD 4 /.4 UCT T UC. 4. UCTC UCTCD UCTC UCTCD. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCTJL, UCL) 4. s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available /

166 Take-Up Units UCT-E Cylindrical bore (with set screws) d ~ L Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T4E~TE TE~TE TXE~TXE TXE~TXE H H H N φn L N L L haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn d H H H L L L L N N N Cr Cr f kg 4 4 / / / / / / / / 4 / 4 / 4 / / 4 / / / / 4 / /. /. /. /. /. /. / / / 4 / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ / 4 / 4 / 4 / / / / / / 4 / 4 4 / 4 / 4 / 4 / 4 / 4 / UCTE UCT-E UCTE UCT-E UCTE UCT4-E UCT4E UCT-4E UCT-E UCTE UCT-E UCTXE UCTX-E UCT-E UCTE UCT-E UCT-E UCTXE UCTX-E UCTX-E UCT-E UCT-E UCT-E UCTE UCT-E UCTX-E UCTXE UCTX-E UCT-4E UCT-E UCTE UCTX-4E UCTXE UCT-E UCT-E UCT-E UCTE UCTX-E UCTX-E UCTXE UCT-E UCT-E UCTE UCT-E UCTX-E UCTXE UCTX-E UC. UC- UC. T4E UC-... UC. UC4- UC4. UC-4 TE UC- UC UC- TXE UCX UCX UC- TE UC UC-.... UC- UCX TXE UCX UCX- UC- UC- TE UC UC UC- UCX- TXE UCX UCX- UC-4 TE UC UC TXE UCX-4 UCX UC- TE UC- UC UC UCX- TXE UCX UCX UC- TE UC- UC UC- UCX- TXE UCX UCX-. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCTEL, UCL) 4. s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available. 4 4

167 Take-Up Units UCT-E Cylindrical bore (with set screws) d ~ L Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T4E~TE TE~TE TXE~TXE TXE~TXE H H H N φn L N L L haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn d H H H L L L L N N N Cr Cr f kg / / / / / / / / / / / / / / / / / / / 4 / 4 / / / / / / / / / / / /. /. /. /. /. /. / / / / 4 / 4 / 4 / 4 4 / 4 / 4 / / / / / / / / / / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~ UCT-E UCT-4E UCTE UCT-E UCTXE UCTX-E UCTX-E UCT-E UCTE UCT-E UCT-E UCTXE UCTX-E UCT-4E UCTE UCTX-4E UCTXE UCT4-44E UCT4E UCTX4-44E UCTX4E UCT-4E UCTE UCT-4E UCTX-4E UCTXE UCTX-4E UCT-E UCTE TE TXE TE TXE TE TXE T4E TX4E TE TXE TE UC- UC-4 UC UC- UCX UCX- UCX- UC- UC UC- UC- UCX UCX- UC-4 UC UCX-4 UCX UC4-44 UC4 UCX4-44 UCX4 UC-4 UC UC-4 UCX-4 UCX UCX-4 UC- UC UCTXE TXE UCX UCT-E UCTE UCTXE UCTX-E TE UC- UC TXE UCX UCX s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCTEL, UCL) 4. s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Housings of nodular graphite cast iron are also available. 4 4

168 Take-Up Units NT-E Cylindrical bore (with eccentric locking collar) d ~ L Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T4E~TE TE~TE H H H N φn L N L L haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn d H H H L L L L N N N Cr Cr f kg 4 4 / / / / / / / / / / 4 / 4 / /.... /. /. /. / / / / / / / 4 / / 4 44 / / / / /. /. / / 4 / 4 / / 4 / 4 / / / 4 / 4 / 4 Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R... ~ / / / / 4 / 4 / NTE NT-E NTE NT-E NTE NT4-E NT4E NT-4E NT-E NTE NT-E NT-E NTE NT-E NT-E NT-E NT-E NT-E NTE NT-E NT-4E NT-E NTE NT-E NT-E NT-E NTE NT-E NT-E NTE NT-E NT-E NT-4E NTE NT-E NT-E NTE NT-E NT-E NT-4E NTE NT4-44E NT4E NT-4E NTE T4E TE TE TE TE TE TE TE TE TE T4E TE N N- N N- N N4- N4 N-4 N- N N- N- N N- N- N- N- N- N N- N-4 N- N N- N- N- N N- N- N N- N- N-4 N N- N- N N- N- N-4 N N4-44 N4 N-4 N For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated.

169 Take-Up Units NCT Cylindrical bore (with concentric locking collar) d ~ L Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T4~T T~T H H H N φn L N L L haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn d H H H L L L L N N N d Cr Cr f kg 4 4 / / / / 4 / 4 / / 4 / / 4 4 / 4 4 / 4 / / 4 / / / / 4 / 4 / / / / / / 4 / 4 / 4 / 4 / Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R... ~ / 4 / 4 / 4 / /. / / 4. /. /. /. /. /.4 / / NCT4- NCT4 NCT-4 NCT- NCT NCT- NCT- NCT NCT- NCT- T4 T T NC4- NC4 NC-4 NC- NC NC- NC- NC NC- NC NCT- T NC NCT- NCT NCT- NCT-4 NCT T T NC- NC NC- NC-4 NC NCT- T NC NCT- NCT- NCT NCT- NCT NCT- T T NC- NC- NC NC- NC NC NCT- T NC NCT NCT- T NC NC NCT- T NC NCT NCT- T NC NC For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated.

170 Take-Up Units NCT-E Cylindrical bore (with concentric locking collar) d ~ L Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T4E~TE TE~TE H H H N φn L N L L haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn d H H H L L L L N N N d Cr Cr f kg 4 4 / / / / 4 / 4 / / 4 / / 4 4 / 4 4 / /. /. /. /. / / / / / / 4 / / / / 4 / 4 / / / / / / 4 / 4 / 4 / 4 / Remarks. In Part No. of unit, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... 4~ -R... ~ / 4 / 4 / 4 / /. / / 4. /. /. /. /. /.4 / / NCT4-E NCT4E NCT-4E NCT-E NCTE NCT-E NCT-E NCTE NCT-E NCT-E T4E TE TE NC4- NC4 NC-4 NC- NC NC- NC- NC NC- NC NCT-E TE NC NCT-E NCTE NCT-E NCT-4E NCTE TE TE NC- NC NC- NC-4 NC NCT-E TE NC NCT-E NCT-E NCTE NCT-E NCTE NCT-E TE TE NC- NC- NC NC- NC NC NCT-E TE NC NCTE NCT-E TE NC NC NCT-E TE NC NCTE NCT-E TE NC NC For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Representative examples of the forms of housing are indicated. 4

171 Take-Up Units UKT Tapered bore (with adapter) d ~ L With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T~T TX~TX T~T +.. T~T TX~TX T~T. T~T +... T4~T.. H H H N φn H H Form and dimension of Lc of TJE (housing with cast iron cover) are shown below. L c TJE Lc = L N L L haft Dia. Dimensions tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn inch inch Open Type One ide Open Type One ide d H H H L L L L N N N kg Cr Cr f Closed Type s kg Closed Type c kg / 4 4 / 4 / 4 / 4 / 4 / / 4 / / / 4 4 / / / 4 4 / / / 4 4 / / 4 / 4 / 4 / / / / / 4 / / / 4 4 / 4 4 / 4 / / 4 / / / 4 / 4 4 / 4 / 4 / 4 / 4 4 / 4 / 4 / 4 / 4 / / 4 / 4 / 4 / 4 / 4 / 4 / / / UKT T UK UKTX TX UKX UKT T UK UKT T UK UKTX TX UKX UKT T UK UKT T UK UKTX TX UKX UKT T UK UKT T UK UKTX TX UKX UKT T UK UKT T UK UKTX TX UKX UKT T UK UKT T UK UKTX TX UKX UKT T UK UKT T UK UKTX TX UKX UKT T UK Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKTJ + HX, UK + HX) HEX HX HEX HX HEX HX HX HEX HX HEX HX HEX HX HX HX HX HX HX HEX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HEX HX HEX HX HEX HX HEX HX HX HX HEX HX HX HEX HX HX HEX UKTC UKTXC UKTC UKTXC UKTC UKTXC UKTC UKTXC UKTC UKTXC UKTC UKTXC UKTC UKTXC UKTCD UKTXCD UKTCD UKTXCD UKTCD UKTXCD UKTCD UKTXCD UKTCD UKTXCD UKTCD UKTXCD UKTCD UKTXCD / UKTFC UKTC UKTFC UKTC UKTFC UKTC UKTFC UKTC UKTFC UKTC UKTFC UKTC UKTFC UKTC UKTFCD UKTCD UKTFCD UKTCD UKTFCD UKTCD UKTFCD UKTCD UKTFCD UKTCD UKTFCD UKTCD UKTFCD UKTCD 4. s for the triple seal type product ( is the double seal type product), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UKTJL + HX, UKL + HX). For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Housings of nodular graphite cast iron are also available. 4 / 4 /

172 Take-Up Units UKT Tapered bore (with adapter) d ~ L With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T~T TX~TX T~T +.. T~T TX~TX T~T. T~T +... T4~T.. H H H N φn H H Form and dimension of Lc of TJE (housing with cast iron cover) are shown below. L c TJE Lc = L N L L haft Dia. Dimensions tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch Unit Housing earing dapter Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. No. No. kn inch inch Open Type One ide Open Type One ide d H H H L L L L N N N kg Cr Cr f Closed Type s kg Closed Type c kg / / / / / 4 / / / / 4 4 / / 4 / / / / / / / 4 / / / / 4 4 / / 4 / 4 / 4 / 4 / / / / / / 4 4 / / / / / / / / / / / / 4 4 / / / / / / / / / / / / / 4 4 / 4 / 4 4 / / 4 4 / 4 / / / / / / / / / / / / UKT T UK UKTX TX UKX UKT T UK UKT T UK UKTX TX UKX UKT T UK UKT T UK UKTX TX UKX UKT T UK UKT T UK UKTX TX UKX UKT T UK UKT T UK UKTX TX UKX UKT T UK HX HX HX HX HX HX HEX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HEX HX HEX HX HEX HX HEX HX HX HEX HX HEX HX HEX UKTC UKTXC UKTC UKTXC UKTC UKTXC UKTC UKTXC UKTC UKTXC UKTCD UKTXCD UKTCD UKTXCD UKTCD UKTXCD UKTCD UKTXCD UKTCD UKTXCD / 4 / UKTFC UKTC UKTFC UKTC UKTFC UKTC UKTFC UKTC UKTFC UKTC UKTFCD UKTCD UKTFCD UKTCD UKTFCD UKTCD UKTFCD UKTCD UKTFCD UKTCD UKT T UK HX. 4. UKTC UKTCD. UKT T UK UKT T UK UKT T UK HEX HX HEX HX HX HEX UKTC UKTC UKTC UKTCD UKTCD UKTCD UKT4 T4 UK4 H4 4.. UKT4C UKT4CD. UKT T UK Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~, X~X, ~. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKTJ + HX, UK + HX) HE H.. 4. UKTC UKTCD UKT T UK H. 4. UKTC UKTCD 4. s for the triple seal type product ( is the double seal type product), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UKTJL + HX, UKL + HX). For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Housings of nodular graphite cast iron are also available / 4 / / /

173 Take-Up Units UCTR Cylindrical bore (with set screws) d ~ L Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X TR~TR +... H H φn N L L haft Dia. Dimensions tandard asic Factor Mass inch inch Unit Housing earing Load Ratings No. No. No. kn d H H L L L N N Cr Cr f kg / / / /... / / / / / / 4 / UCTR-4 UCTR- UCTR UCTR- UCTR- UCTR UCTR- UCTR- UCTR- UCTR- UCTR- UCTR UCTR- TR TR TR Remarks. Part No. of applicable grease fittings are shown below. --UNF... ~. s for the triple seal type product (from is the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCTRJL, UCL). s for the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4. Housings of nodular graphite cast iron are also available. UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC

174 Corrosion Resistant eries Take-Up Units UCT-H Cylindrical bore (with set screws) d ~ L With Pressed tainless teel Cover Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T4H~H +... HH H N φn H L N L L haft Dia. Dimensions Unit Housing earing asic Factor Mass With Pressed tainless teel Cover inch inch No. No. No. Load Ratings Unit No. Dimension Mass kn inch Open Type One ide d H H H L L L L N N N Cr Cr f kg Closed Type s kg 4 4 / / / / / / / / 4 / 4 / / 4 / 4 / 4 4 / 4 4 / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4 / 4 / / / / / / 4 / / 4 / UCT4-H UCT4H UCT-4H UCT-H UCTH UCT-H UCT-H UCTH UCT-H UCT-H UCT-H UCT-H UCT-H UCTH UCT-H UCT-4H UCT-H UCTH UCT-H UCT-H UCT-H UCTH UCT-H UCT-H UCTH UCT-H T4H TH TH TH TH TH TH UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC-4 UC UC- UC- UC- UC UC- UC- UC UC UCT4HC UCTHC UCTHC UCTHC UCTHC UCTHC UCTHC UCT4HCD UCTHCD UCTHCD UCTHCD UCTHCD UCTHCD UCTHCD /

175 Corrosion Resistant eries Take-Up Units UCT-EH Cylindrical bore (with set screws) d ~ L With Pressed tainless teel Cover Variations of tolerance of groove width (s), variations of tolerance of distance between both grooves (Hs), and tolerance of syetry of both groove sides (X) Housing No. s Hs X T4EH~EH +... HH H N φn H L N L L haft Dia. Dimensions Unit Housing earing asic Factor Mass With Pressed tainless teel Cover inch inch No. No. No. Load Ratings Unit No. Dimension Mass kn inch Open Type One ide d H H H L L L L N N N Cr Cr f kg Closed Type s kg 4 4 / / / / / / / / 4 / /. /. / / 4 / 4 / 4 4 / / 4 4 / / / Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of the applicable grease fitting is --UNFN.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. 4 / 4 / / / / / / 4 / / 4 / UCT4-EH UCT4EH UCT-4EH UCT-EH UCTEH UCT-EH UCT-EH UCTEH UCT-EH UCT-EH UCT-EH UCT-EH UCT-EH UCTEH UCT-EH UCT-4EH UCT-EH UCTEH UCT-EH UCT-EH UCT-EH UCTEH UCT-EH UCT-EH UCTEH UCT-EH T4EH TEH TEH TEH TEH TEH TEH UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC-4 UC UC- UC- UC- UC UC- UC- UC UC UCT4EHC UCTEHC UCTEHC UCTEHC UCTEHC UCTEHC UCTEHC UCT4EHCD UCTEHCD UCTEHCD UCTEHCD UCTEHCD UCTEHCD UCTEHCD /

176 ection teel Frame Take-Up Units UCTH Cylindrical bore (with set screws) d ~ T L T With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance between centers of bolt holes (Js, Js) Nominal unit code Js Js UCTH~UCTH ±. ±. H J -φn J L J J haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover inch inch ize Unit earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. kn inch inch inch Open Type One ide Open Type One ide d H L L J J J N T T kg Cr Cr f Closed Type s kg Closed Type c kg 4 4 / / / / / / / / / / / / 4 4 / 4 / / / / / / / 4 / 4 / 4 / / / / 4 / 4 / / / / 4 / / / 4 4 / 4 4 / 4 / /. /.. / M M M M M M / M / M UCTH- UCTH-- UCTH- UCTH-- UCTH- UCTH4-- UCTH4- UCTH-4- UCTH-- UCTH- UCTH-- UCTH-- UCTH- UCTH-- UCTH-- UCTH-- UCTH-- UCTH-- UCTH- UCTH-- UCTH-4- UCTH-- UCTH- UCTH-- UCTH-- UCTH-- UCTH- UCTH-- UCTH-- UCTH- UCTH-- UCTH-- UCTH-4- UCTH- UCTH-- UCTH-- UCTH- UCTH-- UCTH-- UCTH-4- UCTH- Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... ~. s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UCTHJL-, UCL) / 4 / 4 / / M / M UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC UC- UC- UC- UC UC UC-4. UC UC. UC-.4 UC-.4 UC UC.4 UC-. UC-. UC UC-. UC-. UC-4. UC UC-. UC-.4 UC.4 UC-.4 UC-.4 UC-4 UC UCTHC- UCTHCD- UCTHC- UCTHCD- UCTHC- UCTHCD- UCTH4C- UCTH4CD- UCTHC- UCTHCD- UCTHC- UCTHCD- UCTHC- UCTHCD- UCTHC- UCTHC- UCTHCD- UCTHCD- UCTHC- UCTHCD- UCTHC- UCTHCD- UCTHC- UCTHCD- UCTHC- UCTHCD / If heavy load (Pr /Cr >.), vibration, or impact occurs, contact with FYH.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. Tapered bore (with adapter) type products are also available. (Example of Part No. : UKTHJ- + HX, UK + HX) UCTH4FC- UCTHFC- UCTHFC- UCTHFC- UCTHFC- UCTHFC- UCTHFC- UCTHFC- UCTHFC- UCTHFC- UCTH4FCD- UCTHFCD- UCTHFCD- UCTHFCD- UCTHFCD- UCTHFCD- UCTHFCD- UCTHFCD- UCTHFCD- UCTHFCD- 4 4 / / /

177 Channel teel Frame Take-Up Units UCTL Cylindrical bore (with set screws) d ~ 4 With Pressed teel Cover With Cast Iron Cover C Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) and variations of tolerance of distance between centers of bolt holes (Js) Nominal unit code Hs Js UCTL4~ ±. ± UCTL, ±. H H H -φn 4 4 T T M T J L haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover ize Unit earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. kn Open Type One ide Open Type One ide d H H H L J N T T kg Cr Cr f Closed Type s kg Closed Type c kg M M M M M M M M M M M M M M M M M M M M M M M M UCTL4- UCTL4- UCTL4- UCTL4-4 UCTL- UCTL- UCTL- UCTL-4 UCTL- UCTL- UCTL- UCTL-4 UCTL- UCTL- UCTL- UCTL-4 UCTL- UCTL- UCTL- UCTL-4 UCTL- UCTL- UCTL- UCTL-4 UC4 UC4 UC4 UC4 UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter codes. (ee Table. in P..). Part No. of applicable grease fittings is C--UNF.. s for the triple seal type product (4 and are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UCTLJL-, UCL) 4. The unit should be mounted so that load is applied to the frame mounting surface vertically and downward UCTL4C- UCTL4C- UCTL4C- UCTL4C-4 UCTL4CD- UCTL4CD- UCTL4CD- UCTL4CD UCTLC- UCTLCD UCTLC- UCTLCD UCTLC- UCTLCD UCTLC-4 UCTLCD UCTLC- UCTLCD-. UCTLFC- UCTLFCD-... UCTLC- UCTLCD-. UCTLFC- UCTLFCD-... UCTLC- UCTLCD-. UCTLFC- UCTLFCD-... UCTLC-4 UCTLCD-4. UCTLFC-4 UCTLFCD UCTLC- UCTLCD-. UCTLFC- UCTLFCD-..4. UCTLC- UCTLCD-. UCTLFC- UCTLFCD-..4. UCTLC- UCTLCD-. UCTLFC- UCTLFCD-..4. UCTLC-4 UCTLCD-4 UCTLFC-4 UCTLFCD UCTLC- UCTLCD-. UCTLFC- UCTLFCD UCTLC- UCTLCD-. UCTLFC- UCTLFCD UCTLC- UCTLCD- UCTLFC- UCTLFCD UCTLC-4 UCTLCD-4. UCTLFC-4 UCTLFCD UCTLC- UCTLCD-. UCTLFC- UCTLFCD UCTLC- UCTLCD-. UCTLFC- UCTLFCD UCTLC- UCTLCD-. UCTLFC- UCTLFCD UCTLC-4 UCTLCD-4 UCTLFC-4 UCTLFCD-4. If heavy load (Pr /Cr >.), vibration, or impact occurs, contact with FYH.. Tapered bore (with adapter) type bearing units are also available. (Example of Part No. : UKTLJ- + HX, UK + HX). If frame parts need to be corrosion resistant, contact with FYH.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit

178 Channel teel Frame Take-Up Units UCTU Cylindrical bore (with set screws) d 4 ~ With Pressed teel Cover With Cast Iron Cover C With Cast Iron Cover C Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) and variations of tolerance of distance between centers of bolt holes (Js) Nominal unit code Hs Js UCTU~ UCTU~ ± ±. UCTU~ ±. H H -φn H H 4-φN H H T T M T J L 4 M T T T J L 4 UCTU UCTU haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover ize Unit earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. kn Open Type One ide Open Type One ide d H H H L J N T T kg Cr Cr f Closed Type s kg Closed Type c kg ,,,,,,,,,,,,,,,,, 4,4,4,4,4,,,,,,,,,,,,,4,,,,,,,,,,,,,,,,,,,,,,,,,, 4,4,4,4, M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. C--UNF... ~ C-R...,, ~. s for the triple seal type product, suffix code L follows the Part No. of unit or bearing. (Example of Part No. : UCTUJL-, UCL) UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU4- UCTU4- UCTU4- UCTU4- UCTU4- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC UC4 UC4 UC4 UC4 UC4 UC UC UC UC UC UC UC UC UC UC UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUFC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTU4C- UCTU4C- UCTU4C- UCTU4C- UCTU4C- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUFCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTU4CD- UCTU4CD- UCTU4CD- UCTU4CD- UCTU4CD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- 4. The unit should be mounted so that load is applied to the frame mounting surface vertically and downward.. If heavy load (Pr /Cr >.), vibration, or impact occurs, contact with FYH.. Tapered bore (with adapter) type bearing units are also available. (Example of Part No. : UKTUJ- + HX, UK + HX). If frame parts need to be corrosion resistant, contact with FYH.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit

179 Channel teel Frame Take-Up Units UCTU Cylindrical bore (with set screws) d ~ With Pressed teel Cover With Cast Iron Cover C With Cast Iron Cover C Variations of tolerance of distance from mounting bottom to center of spherical bore (Hs) and variations of tolerance of distance between centers of bolt holes (Js) Nominal unit code Hs Js UCTU~ UCTU~ ± ±. UCTU~ ±. H H -φn H H 4-φN H H T T M T J L 4 M T T T J L 4 UCTU UCTU haft Dia. Dimensions olt tandard asic Factor With Pressed teel Cover With Cast Iron Cover ize Unit earing Mass Load Ratings Unit No. Dimension Mass Unit No. Dimension Mass No. No. kn Open Type One ide Open Type One ide d H H H L J N T T kg Cr Cr f Closed Type s kg Closed Type c kg,,,,,4,,,,,4,,,,,,,, M M M M M M M M M M Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. C--UNF... ~ C-R...,, ~. s for the triple seal type product, suffix code L follows the Part No. of unit or bearing. (Example of Part No. : UCTUJL-, UCL) UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UCTU- UC UC UC UC UC UC UC UC UC UC UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUC- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- UCTUCD- 4. The unit should be mounted so that load is applied to the frame mounting surface vertically and downward.. If heavy load (Pr /Cr >.), vibration, or impact occurs, contact with FYH.. Tapered bore (with adapter) type bearing units are also available. (Example of Part No. : UKTUJ- + HX, UK + HX). If frame parts need to be corrosion resistant, contact with FYH.. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit

180 teel Plate Frame Take-Up Units PTH Cylindrical bore (with set screws) d ~ L T T Variations of tolerance of distance between centers of bolt holes (Js, Js) Nominal unit code Js Js PTH~PTH ±. ±. H J J J J L -φn haft Dia. Dimensions olt Unit earing asic Factor Mass inch ize No. No. Load Ratings inch kn d H L L J J J N T T Cr Cr f kg / / / / / / / / / / /. /. /.. /.4 Remarks. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. If heavy load (Pr /Cr >.), vibration, or impact occurs, contact with FYH / M / M / M / M / M PTH PTH PTH PTH PTH

181 teel Plate Frame Take-Up Units NPTH Cylindrical bore (with set screws) d ~ J T L J T Variations of tolerance of distance between centers of bolt holes (Js, Js) Nominal unit code Js Js NPTH~NPTH ±. ±. H H J 4-φN L haft Dia. Dimensions olt Unit earing asic Factor Mass inch ize No. No. Load Ratings inch kn d H H L L J J J N T T Cr Cr f kg / / / 4 4 / / / / / / 4 / / / / 4 / 4 / / / / / /..... / / / / / / / /.... /..... / 4. Remarks. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.. If heavy load (Pr /Cr >.), vibration, or impact occurs, contact with FYH. / / M / M / M / M / M NPTH NPTH NPTH NPTH NPTH

182 Cartridge Units UCC Cylindrical bore (with set screws) d ~ (4) r r φh d (4) ~ Variations of tolerance of outside diameter (Hs), variations of tolerance of width (s), and tolerance of circumferential runout of outside diameter (Y) Housing No. Hs s Y C4~C. C~C CX~CX C~C ±... CX~CX C~C C~C CX~CX C~C4.4 C~C. C.4 C~C ±...4 C4~C. haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn 4 4 d H r Cr Cr f kg / / / / / / / / 4. / / / 4 / UCC UCC- UCC UCC- UCC UCC4- UCC4 UCC-4 UCC- UCC UCC- UCCX UCCX- UCC UCC- UCC- UCC UCC- UCC- UCCX UCCX- UCCX- C4 C CX C C CX UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UCX UCX- UC UC- UC- UC UC- UC- UCX UCX- UCX UCC C UC.... UCC- UCC- UCC- UCC UCC- UCCX- UCCX UCCX- C CX UC- UC- UC- UC UC- UCX- UCX UCX UCC C UC.4... UCC-4 UCC- UCC UCCX-4 UCCX UCC-4 UCC UCC- UCC- UCC- UCC C CX C C UC-4 UC- UC UCX-4 UCX UC-4 UC UC- UC- UC- UC Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCCJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit. haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn 4 d H r Cr Cr f kg / 4.4. / 4.4 / / / / / /. /. 4.. / / UCCX- UCCX- UCCX UCC- UCC UCC- UCC- UCC UCC- UCCX- UCCX UCCX- CX C C CX UCX- UCX- UCX UC- UC UC- UC- UC UC- UCX- UCX UCX UCC C UC.... UCC- UCC-4 UCC UCC- UCCX UCCX- UCCX- UCC- UCC UCC- UCC- UCC UCC- UCC- UCCX UCCX- UCC UCC- UCC-4 UCC UCC-4 UCC UCC4-44 UCC4 UCC-4 UCC UCC-4 C CX C C CX C C C C4 C UC- UC-4 UC UC- UCX UCX- UCX- UC- UC UC- UC- UC UC- UC- UCX UCX- UC UC- UC-4 UC UC-4 UC UC4-44 UC4 UC-4 UC UC UCC C UC... UCC C UC... Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCCJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.

183 Cartridge Units UCC Cylindrical bore (with set screws) d ~ 4 r r φh Variations of tolerance of outside diameter (Hs), variations of tolerance of width (s), and tolerance of circumferential runout of outside diameter (Y) Housing No. Hs s Y C4~C. C~C CX~CX C~C ±... CX~CX C~C C~C CX~CX C~C4.4 C~C. C.4 C~C ±...4 C4~C. haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn d H r Cr Cr f kg / / / UCC- UCC C UC- UC 4.. UCC C UC.. UCC UCC- UCC-4 C UC UC- UC UCC C UC 4.. UCC C UC.. UCC4 C4 UC4.. UCC C UC UCC C UC 4.. Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~. s for the triple seal type product (from to are the double seal type products), suffix code L (L) follows the Part No. of unit or bearing. (Example of Part No. : UCCJL, UCL) 4. For the dimensions and forms of applicable bearings, see the dimensional tables of ball bearing for unit.

184 Cartridge Units UKC Tapered bore (with adapter) d ~ () r r φh d () ~ Variations of tolerance of outside diameter (Hs), variations of tolerance of width (s), and tolerance of circumferential runout of outside diameter (Y) Housing No. Hs s Y C. C~C CX~CX C~C ±... CX~CX C~C C~C CX~CX C~C4.4 C~C. C.4 C~C ±...4 C4~C. haft Dia. Dimensions Unit Housing earing asic Factor dapter Mass inch inch No. No. No. Load Ratings No. kn 4 4 d H r Cr Cr f kg / / / 4 / / 4 / 4 / 4 / 4 / 4 / 4 / / UKC C UK 4... UKCX CX UKX... UKC C UK... UKC C UK... UKCX CX UKX..4. UKC C UK... UKC C UK..4. UKCX CX UKX.. 4. UKC C UK.4.. UKC C UK.. 4. UKCX CX UKX UKC C UK UKC C UK UKCX CX UKX UKC C UK 4... UKC C UK UKCX CX UKX UKC C UK... UKC C UK UKCX CX UKX HEX HX HEX HX HEX HX HX HEX HX HEX HX HEX HX HX HX HX HX HX HEX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HEX HX HEX HX HEX HX HEX HX HX HX HEX HX HX HEX Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKCJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UKCJL + HX, UKL + HX). s for the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter haft Dia. Dimensions Unit Housing earing asic Factor dapter Mass inch inch No. No. No. Load Ratings No. kn d H r Cr Cr f kg / / / / / / / / / / / UKC C UK. 4.. UKC C UK UKCX CX UKX UKC C UK... UKC C UK UKC C UK... UKC C UK.. UKC C UK.. UKC C UK.. HX HX HEX HX HX HX HX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HX HEX UKC C UK 4. HX. UKC C UK. UKC C UK 4. UKC C UK. HEX HX HEX HX HX HEX UKC4 C4 UK4. H4. UKC C UK 4. HE H UKC C UK 4. H. Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~, X~X, ~ -R... ~. In Part No. of unit with adapters and bearing with adapters, Part No. of applicable adapter follow the Part No. shown in the dimensional tables. (Example of Part No. : UKCJ + HX, UK + HX) 4. s for the triple seal type product ( is the double seal type product), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UKCJL + HX, UKL + HX). s for the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter

185 Hanger Units UCH Cylindrical bore (with set screws) d ~ C H H H N L Note ) Dimensions N screw hole is apply JI (Taper Pipe Threads) standards. It can not apply to the Parallel Pipe Male Thread. lso, below shown the dimensions of Parallel Pipe Female Thread. Female Thread Thread Nominal of Thread Major Diameter Pitch Diameter Minor Diameter Number of Threads in.4 ( ) pply Male Thread D D D n Rp R Rp.4.. R Rp R Rp R haft Dia. Dimensions Unit Housing earing asic Factor Mass inch inch No. No. No. Load Ratings kn d H L H H N ) C Cr Cr f kg 4 4 / / / / / / / / / / / 4 / 4 / 4 / 4 / 4 / / / / 4 / 4 / 4 4 / Rp Rp Rp Rp Rp / Rp / Rp Rp Rp Rp Rp Rp Remarks. In Part No. of unit and units with covers, fitting codes follow bore diameter numbers. (ee Table. in P..). Part No. of applicable grease fittings are shown below. --UNF... ~ -R... ~..... UCH UCH- UCH UCH- UCH UCH4- UCH4 UCH-4 UCH- UCH UCH- UCH- UCH UCH- UCH- UCH- UCH- UCH- UCH UCH- UCH-4 UCH- UCH UCH- UCH- UCH- UCH UCH- UCH- UCH UCH- UCH- UCH-4 UCH UCH- UCH- UCH UCH- UCH- UCH-4 UCH UCH4-44 UCH4 UCH-4 UCH UCH-4 H4 H H H H H H H H H H4 H UC UC- UC UC- UC UC4- UC4 UC-4 UC- UC UC- UC- UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC- UC- UC-4 UC UC- UC- UC UC- UC- UC-4 UC UC4-44 UC4 UC-4 UC UC s for the triple seal type product (from to are the double seal type products), suffix code L (or L) follows the Part No. of unit or bearing. (Example of Part No. : UCHJL, UCL) 4. For the dimensions and forms of applicable bearings and adapters, see the dimensional tables of ball bearing for unit and adapter.. Tapered bore (with adapter) type products are also available. (Example of Part No. : UKHJ + HX, UK + HX) 4

186 all earing Inserts UC,, -RKP, U Cylindrical bore (with set screws) d ~ C C -º G C C -º G C -º G C C -º G C -º G φd r r φd r r r φd φd φd UC -RKP U UC UC-L -RKP U haft Dia. Dimensions asic Factor earing Dimensions et crew Mass inch Load Ratings No. rg. ore kn G d D C r (min.) tandard L Type C Cr Cr f inch inch inch inch inch inch inch inch inch kg U M U..4. M U..4. M M RKP M UC UCL M.. / Remarks. U type product is the clean series ball bearing for unit.. From UC to are the double seal type products (L) RKP UC- U RKP UC - -RKP UC- U RKP UC 4-4-RKP UC4- U4 4 4RKP UC4-4 -4RKP UC-4 - -RKP UC- U RKP UC UC UCX - -RKP UC- UC- UCX- - -RKP UC- UC-L UCL UC-L UCL UC4-L UC4L UC-4L UC-L UCL UCXL UC-L UCX-L UC-L M4. M. M. M. M4. M. M. M. M. M. M. M. M. M. M. M. M. M. M. No.-UNF No.-UNF -UNF No.-UNF No.-UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF

187 all earing Inserts UC,, -RKP, U Cylindrical bore (with set screws) d ~ 4 C C -º G C C -º G C -º G C C -º G C -º G φd r r φd r r r φd φd φd UC -RKP U UC UC-L -RKP U haft Dia. Dimensions asic Factor earing Dimensions et crew Mass inch Load Ratings No. rg. ore kn G d D C r (min.) tandard L Type C Cr Cr f inch inch inch inch inch inch inch inch inch kg U M. M RKP M UC UCL M UCX UC UCXL M M... / RKP UC- UCX- - -RKP UC- UCX- - -RKP UC- UC-L UCX-L UC-L UCX-L UC-L / UC- UC-L /-4UNF UNF RKP UNF UC- UC-L /-4UNF UCX- UCX-L /-4UNF. / RKP UC UCX UC - -RKP UC- UCX- -4-4RKP UC-4 UCX-4 UC-4 UCL UCXL UCL UC-L UCX-L UC-4L UCX-4L UC-4L / UC- UC-L /-4UNF RKP UC UCX UC UCL UCXL UCL M M M M M UC- UC-L /-4UNF. / UC- UC-L /-4UNF UCX- UCX-L UNF Remarks. U type product is the clean series ball bearing for unit.. From UC to are the double seal type products (L) UC- UCX- UC- UC-L UCX-L UC-L M. M. M M M M. M. -UNF -UNF -UNF /-4UNF -UNF -UNF -UNF /-4UNF -UNF -UNF /-4UNF -UNF -UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF -4UNF

188 all earing Inserts UC,, -RKP, U Cylindrical bore (with set screws) d 4 ~ () C C -º G C C -º G C -º G C C -º G C -º G φd r r φd r r r φd φd φd UC -RKP U UC UC-L -RKP U haft Dia. Dimensions asic Factor earing Dimensions et crew Mass inch Load Ratings No. rg. ore kn G d D C r (min.) tandard L Type C Cr Cr f inch inch inch inch inch inch inch inch inch kg UC UCX UC UCL UCXL UCL M M. M UC- UC-L UNF. / UC- UC-L UNF UCX- UCX-L UNF UC UCX UC UC- UCX- UC- UC- UCL UCXL UCL UC-L UCX-L UC-L UC-L UC-4 UC-4L UNF UC UCX UC UCL UCXL UCL M. M. M.... / UC- UCX- UC- UC-L UCX-L UC-L UCX- UCX-L UNF UC- UC-L UNF UC UCX UC UCL UCXL UCL M. M. M UC- UC-L UNF. / / Remarks. U type product is the clean series ball bearing for unit.. From UC to are the double seal type products (L) UC- UCX- UC- UC-4 UCX-4 UC-4 UC UCX UC UC4-44 UCX4-44 UC4-44 UC4 UCX4 UC4 UC-4 UCX-4 UC-4 UC UCX UC UC-4 UCX-4 UC-4 UC-L UCX-L UC-L UC-4L UCX-4L UC-4L UCL UCXL UCL UC4-44L UCX4-44L UC4-44L UC4L UCX4L UC4L UC-4L UCX-4L UC-4L UCL UCXL UCL UC-4L UCX-4L UC-4L M. M. M. M. M. M. M. M. M. M. M. M. M. M. M4. M. M. M4. M4. -4UNF -4UNF -4UNF -4UNF -4UNF -4UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF

189 all earing Inserts UC,, -RKP, U Cylindrical bore (with set screws) d () ~ 4 C C -º G C C -º G C -º G C C -º G C -º G φd r r φd r r r φd φd φd UC -RKP U UC UC-L -RKP U haft Dia. Dimensions asic Factor earing Dimensions et crew Mass inch Load Ratings No. rg. ore kn G d D C r (min.) tandard L Type C Cr Cr f inch inch inch inch inch inch inch inch inch kg UC- UC-L UNF UC UCX UC UCL UCXL UCL M. M. M UC- UC-L UNF UC UCX UC UCL UCXL UCL M. M. M..4.. / UCX- UCX-L UNF UC- UC-L UNF UC- UC-L M UC UCX UC UCL UCL M. M4. M UC UCL M UCX M UC UCL M.. / UCX UNF UC- UC-L M UCX UNF UC-4 UC-4L M Remarks. U type product is the clean series ball bearing for unit.. From UC to are the double seal type products (L) UC UC UC4 UC UC UCL UC4L UCL UCL M. M. M. M. M

190 all earing Inserts UC-, U- (tainless steel series) Cylindrical bore (with set screws) d ~ C C -º G C -º G r r φd φd UC- U- UC- U- haft Dia. Dimensions asic Factor earing Dimensions et crew Mass inch Load Ratings No. rg. ore kn G d D C r (min.) tandard C Cr Cr f inch inch inch inch inch inch inch inch kg U..4. M U UCX M. M UC-X M / / / / / / / / / Remark series product is the stainless steel series ball bearing for unit U UCX UC-X U UCX UC4- U4 UC4 UC-4 UC- U UC UC- UC- U UC UC- UC- UC- UC- UC- UC UC- UC-4 UC- UC UC- UC- UC- UC UC- UC- UC UC- UC- UC-4 UC UC- UC- UC UC- UC M4. M. M. M4. M. M. M. M. M. M. M. M. M. M. M. M. M. M. M M M M M M M M M M M M M M M M M. M. M. M. M. M. M. M

191 G φd C r -F G φd C C r -F N all earing Inserts φd C G C r N, -F, N Cylindrical bore (with eccentric locking collar) haft Dia Dimensions asic Factor earing Dimensions et crew Mass inch Load Ratings No. rg.ore kn d D C r (min.) Cr Cr f C d inch kg inch inch inch inch inch inch inch inch inch F N M. M. M F N UNF -UNF -UNF F N M. M. M N UNF -UNF F N M. M. M F N UNF -UNF -UNF F N M. M. M N UNF -UNF.. / F N UNF -UNF -UNF F N M. M. M F N UNF -UNF -UNF F N /-4UNF /-4UNF /-4UNF F N M M M..4.4 / F N- N /-4UNF /-4UNF /-4UNF /-4UNF F N /-4UNF /-4UNF /-4UNF F N /-4UNF /-4UNF /-4UNF... / F N /-4UNF /-4UNF /-4UNF... d ~ ()

192 all earing Inserts, -F, N Cylindrical bore (with eccentric locking collar) d () ~ C G C C G C C G φd r r φd φd r -F N -F N haft Dia Dimensions asic Factor earing Dimensions et crew Mass inch Load Ratings No. rg.ore kn d D C r (min.) C d Cr Cr f inch inch inch inch inch inch inch inch inch inch kg / / 4 / 4 / / / F N- F N - -F N- N- -4-4F N-4 N-4 - -F N- F N -F N- -F N- N- -F N- F N -F N- -F N- N- F N N- -F N- -4F N-4 F N -F N- N- N- N N M M M M M M M M M M M. M. M. /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF -4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF -4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF -4UNF /-4UNF -4UNF -4UNF -4UNF -4UNF -4UNF -4UNF -4UNF -4UNF -4UNF

193 all earing Inserts, -F, N Cylindrical bore (with eccentric locking collar) d ~ C G C C G C C G φd r r φd φd r -F N -F N haft Dia Dimensions asic Factor earing Dimensions et crew Mass inch Load Ratings No. rg.ore kn d D C r (min.) C d Cr Cr f inch inch inch inch inch inch inch inch inch inch kg N UNF N M..4 / / N4-44 N4 N4-4 N N-4 N M. M. -4UNF -UNF -4UNF -UNF

194 all earing Inserts NC Cylindrical bore (with concentric locking collar) d ~ C C φd r haft Dia. Dimensions asic Factor earing Collar Dimensions Cap crew Mass inch Load Ratings No. No. kn d D C r C d inch Cr Cr f inch inch inch inch inch inch inch inch inch kg NC4- UCL4 No.-UNC NC4 UCL4M M / / / NC-4 NC- NC NC- NC- NC NC- NC- UCL UCL UCLM UCL UCL UCLM UCL UCL NC- UCL No.-4UNC. NC- UCL No.-4UNC NC UCLM M.. NC- UCL No.-4UNC NC-4 UCL No.-4UNC NC UCLM M NC- UCL No.-4UNC. / NC- UCL No.-4UNC NC- UCL No.-4UNC. NC UCLM M. / NC- UCL -UNC NC UCLM M.4 NC- UCL -UNC NC- UCL UNC. NC UCLM M / NC- UCL -UNC NC- UCL /-UNC NC UCLM M NC- UCL /-UNC. / No.-UNC No.-UNC M4. No.-UNC No.-UNC M4. No.-UNC No.-UNC.4.

195 all earing Inserts ERC Cylindrical bore (with concentric locking collar) Cylindrical O. D. d ~ Cc r C f a r r φd φd haft Dia. Dimensions asic Factor earing Collar Dimensions Cap crew Mass inch Load Ratings No. No. kn d D C r r (min.) Cc a f d D inch Cr Cr f inch inch inch inch inch inch inch inch inch inch inch inch inch kg ERC4- UCL4 No.-UNC ERC4 UCL4M M / / / ERC-4 ERC- ERC ERC- ERC- ERC ERC- ERC- UCL UCL UCLM UCL UCL UCLM UCL UCL ERC- UCL No.-4UNC. ERC- UCL No.-4UNC ERC UCLM M.. ERC- UCL No.-4UNC ERC-4 UCL No.-4UNC ERC UCLM M ERC- UCL No.-4UNC. / ERC- UCL No.-4UNC ERC- UCL No.-4UNC. ERC UCLM M. / ERC- UCL -UNC ERC UCLM M. ERC- UCL -UNC ERC- UCL UNC. ERC UCLM M / ERC- UCL -UNC ERC- UCL /-UNC ERC UCLM M ERC- UCL /-UNC. / No.-UNC No.-UNC M4. No.-UNC No.-UNC M4. No.-UNC No.-UNC.4. 4

196 all earing Inserts UK Tapered bore (with adapter) d ~ () C C C C L φd φd Taper Taper UK UK+H UK UK-L dapter haft Dia. Dimensions asic Factor earing H eries dapter inch inch Load Ratings No. Mass dapter Dimensions Mass leeve kn kg No. inch No. d d D L C C Cr Cr f tandard L Type tandard L Type d kg HEX...4 EX 4... UK UKL HX X HEX...4 EX... UKX.. HX X HEX...4 EX... UK.4. HX X HX.4.. X... UK UKL... HEX 4 HEX..... HX.4.. X..4. UKX.4.. HEX 4 HEX HX.4.. X... UK HEX 4 HEX HX..4.4 X..4. UK UKL HX 4 X..... HX..4.4 X.. 4. UKX.. 4 HX 4 X UK UKL UK UKL UKX UK UKL UK UKL UKX UK UKL UK UKL UKX.... UK UKL UK UKL UKX. Remarks. In Part No. of unit with adapters, Part No. of applicable adapters follow the Part No. shown in the dimensional tables. (Example of Part No. : UK + HX, UKL + HX) HX HX HEX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HEX HX HEX HX HEX HX HEX HX HX HX HEX HX HX HEX X X EX X X EX X X EX X X EX X EX X EX X EX X EX X EX X X X EX X X EX. dapter series applicable to UK series UK... HX series UKL (or L)... HX series. UK is the double seal type product (L). 4. Inch bore diameter series adapters are also available (see the dimensional tables of adapters).

197 all earing Inserts UK Tapered bore (with adapter) d () ~ () C C C C L φd φd Taper Taper UK UK+H UK UK-L dapter haft Dia. Dimensions asic Factor earing H eries dapter inch inch Load Ratings No. Mass dapter Dimensions Mass leeve kn kg No. inch No. d d D L C C Cr Cr f tandard L Type tandard L Type d kg UK UKL UK UKL UKX.4... UK UKL UK UKL UKX.... UK UKL UK UKL UKX... UK UKL UK UKL UKX.4.. UK UKL UK UKL UKX... UK UKL.. HX HX HEX HX HX HX HX HX HX HEX HX HX HEX HX HX HEX HX HX HEX HX HEX HX HEX HX HEX HX HEX HX HEX HX HX HEX HX HEX HX HEX.. 4. UK UKL.. HX. 4.4 UKX. HX 4. UK UKL.. HX. UK UKL.. HX 4.4 UKX. Remarks. In Part No. of unit with adapters, Part No. of applicable adapters follow the Part No. shown in the dimensional tables. (Example of Part No. : UK + HX, UKL + HX) HEX HX X X EX X X X X X X EX X X EX X X EX X X EX X EX X EX X EX X EX X EX X X EX X EX X EX. X. X. X. X. EX X. dapter series applicable to UK series UK... HX series UKL (or L)... HX series. UK is the double seal type product (L). 4. Inch bore diameter series adapters are also available (see the dimensional tables of adapters).

198 all earing Inserts UK Tapered bore (with adapter) d () ~ C C C C L φd φd Taper Taper UK UK+H UK UK-L dapter haft Dia. Dimensions asic Factor earing H eries dapter inch inch Load Ratings No. Mass dapter Dimensions Mass leeve kn kg No. inch No. d d D L C C Cr Cr f tandard L Type tandard L Type d kg HEX... EX 4. UK UKL... 4 HX X UK UKL.. HX HEX. UK4 UK4L.. H4 4. UK UKL.. Remarks. In Part No. of unit with adapters, Part No. of applicable adapters follow the Part No. shown in the dimensional tables. (Example of Part No. : UK + HX, UKL + HX) HE H 4. UK UKL.. H X EX E.. dapter series applicable to UK series UK... HX series UKL (or L)... HX series. UK is the double seal type product (L). 4. Inch bore diameter series adapters are also available (see the dimensional tables of adapters).

199 all earing Inserts ER, R Cylindrical bore (with set screws), Cylindrical O. D. d ~ C C C f a r r -º G C r -º G φd r φd φd r ER R ER R haft Dia. Dimensions asic Factor earing Dimensions et crew Mass inch inch Load Ratings No. inch rg. ore kg kn G d D C r (min.) r (min.) Cr Cr f (ER) (R) Cc a f D inch (ER) (R) / / / / / / / / / ER ER- ER ER- ER ER4- ER4 ER-4 ER- ER ER- ER- ER ER- ER- ER- ER- ER- ER ER- ER-4 ER- ER ER- ER- ER- ER ER- ER- ER ER- ER- ER-4 ER ER- ER- ER ER- ER- R R- R R- R R4- R4 R-4 R- R R- R- R R- R- R- R- R- R R- R-4 R- R M. M. M. M. M. M. M M M M. M. M. -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF -UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF /-4UNF -4UNF -4UNF -4UNF -4UNF -4UNF -4UNF -4UNF -4UNF -4UNF

200 all earing Inserts -RK Cylindrical bore (with set screws) Cylindrical O. D. d ~ -FP Cylindrical bore (with eccentric locking collar) Cylindrical O. D. φd r r C -º G φd r C G -RK -FP -RK -FP 4 haft Dia. Dimensions asic Factor earing Dimensions et crew Mass inch Load Ratings No. rg. ore kn d D C r (min.) d C Cr f inch inch inch inch inch inch inch inch inch inch kg RK. 4. M FP M RK. 4. No.-UNF FP UNF RK. 4. M FP M RK.. 4. No.-UNF RK. 4. M FP M RK.. -UNF FP UNF RK.. M FP M RK UNF. / RK.... -UNF... / FP UNF RK.... M FP M RK.... -UNF FP UNF RK.. -UNF FP /-4UNF RK.. M FP M.4 / RK.. -UNF.. / FP /-4UNF RK.. -UNF FP /-4UNF RK... -UNF FP /-4UNF. / FP /-4UNF RK... -UNF FP /-4UNF RK... M FP M. / RK... -UNF.4.. / FP /-4UNF RK.4. /-4UNF FP /-4UNF. / FP /-4UNF RK.4. M FP M FP /-4UNF. / FP /-4UNF FP /-4UNF FP M FP /-4UNF. / FP /-4UNF FP M FP UNF FP UNF FP.4... M.. / FP UNF.

201 all earing Inserts C Cylindrical bore d ~ 4 C φd r haft Dia. Dimensions asic Factor earing Mass Load Ratings No. kn d D C r (min.) inch inch inch inch C Cr f kg C C C C C C.

202 earing dapter HX d ~ haft Dia. d Dimensions dapter leeve Lock Nut Washer Mass inch inch No. No. No. No. kg (H) (HE) (H) (H) d (H) (HE) (H) (H) (H) (HE) (H) (H) (H) (HE) (H) (H)...4 HX HEX X EX N N WX WX.. / HX HEX HX HX X EX X X N N WX WX....4 / HX HX X X N WX HX HEX X EX N N WX WX.. 4 /..4. HX HEX HX X EX X N N WX WX... 4 /..4. HX HEX HX HX X EX X X N N WX WX /..4. HX HEX HX HX X EX X X N N N WX WX WX HX HX X X N N WX WX.4. / HX HEX HX HX X EX X X N N N WX WX WX.... /.4.. HX HEX HX HX X EX X X N N WX WX.... / HX HEX HX X EX X N N WX WX...4 /.. 4. HX HEX HX X EX HX N N WX WX.4..4 / HX HEX HX X EX X N WX HX HEX X EX N N WX WX.. /... HX HEX HX X EX X N N WX WX HX HEX X EX N N WX WX / H4 HE4 H4 4 E4 4 N4 W4...

203 earing dapter HX d ~ haft Dia. d Dimensions dapter inch inch No. (H) (HE) (H) (H) d (H) (HE) (H) (H) leeve Lock Nut Washer Mass No. No. No. kg (H) (HE) (H) (H) (H) (HE) (H) (H) 4 4 / 4 / H H HE HE H H E E N N N W W W

204 Parts and ccessories Parts and ccessories. Part No. of teel Plate Covers Table. Part No. of steel plate cover for UC type bearing Table. Part No. of steel plate cover for UK type bearing earing No. haft dia. () teel plate cover No. Open type ealed type earing No. haft dia. () teel plate cover No. Open type ealed type UC C 4 D 4 UC C 4 D 4 UC C 4 D 4 UC4 C 4 D 4 UC C D UC C D UC C D UC 4 C 4 D UC 4 C 4 D UC C D UC C D UC C D UC C D UC4 C4 D4 UC C D UC C D UC C D UC C D UCX C D UCX C D UCX C D UCX 4 C 4 D UCX 4 C 4 D UCX C D UCX C D UCX C D UCX C4 D4 UCX4 C D UCX C D UCX C D UCX C D UK C D UK C D UK C D UK C D UK 4 C 4 D UK 4 C 4 D UK C D UK C D UK C D UK C D UK C D UK C D UK C D UKX C D UKX C D UKX C D UKX C D UKX 4 C 4 D UKX 4 C 4 D UKX C D UKX C D UKX C4 D4 UKX C D UKX C D UKX C D Remark In the Part No. of the steel plate covers for shouldered shaft, shaft diameter follows the basic code of the cover. For example, Part No. of the cover for a shaft with diameter for UC is C.

205 . Part No. of Cast Iron Covers Table. Part No. of cast iron cover for UC type bearing Table.4 Part No. of cast iron cover for UK type bearing earing No. haft dia. () Cast iron cover No. Open type Closed type Mounting bolt (reference) UC4 4FC 4FD M (4FC ) ) (4FD) ) (M4) UC FC FD M (FC ) ) (FD) ) (M4) UC FC FD M4 UC FC FD M4 UC 4 FC 4 FD UC 4 FC 4 FD UC FC FD M4 UC FC FD UC FC FD UC FC FD M4 UC4 4FC 4FD UC FC FD UC FC FD M UC FC FD UC FC FD UCX XC XD M (XC ) ) (XD) ) UCX XC XD (XC ) ) (XD) ) UC C D M4 UC C D UC C D UC 4 C 4 D M UC 4 C 4 D UC C D UC C D M UC C D UC C D UC4 4C 4D M UC C D UC C D UC C D M UC C D UC C D UC C D M UC C D UC C D UC4 4C 4D M UC C D M UC 4 C 4 D earing No. haft dia. () Cast iron cover No. Open type Closed type Mounting bolt (reference) UK FC FD M (FC ) ) (FD) ) (M4) UK FC FD M4 UK FC FD M4 UK FC FD UK 4 FC 4 FD UK 4 FC 4 FD M4 UK FC FD UK FC FD UK FC FD M4 UK FC FD UK FC FD M UK FC FD UK FC FD UKX XC XD M (XC ) ) (XD) ) UKX XC XD (XC ) ) (XD) ) UK C D M4 UK C D UK C D UK C D M UK 4 C 4 D UK 4 C 4 D UK C D M UK C D UK C D UK C D M UK C D UK C D M UK C D UK C D UK C D M UK C D UK4 4C 4D M UK C D M UK C D Note ) Items in parentheses are applicable to the pillow type (P), square four-bolt flange type (F), oval flange type (FL), and the take-up type (T) bearings, and can be mounted to housings with three hexagon socket head cap screws (use four to mount other items). ) Items in parentheses are applicable to the round flange cartridge type bearing (FC), and can be mounted to housings with three hexagon socket head cap screws (use four to mount other items). Remark In the nominal codes of the cast iron covers for shouldered shaft, shaft diameter follows the basic code of the cover. For example, Part No. of the cover for a shaft with diameter for UC is FC.

206 4

207 PHERICL ROLLER ERING UNIT Contents tructure and Features. tructure.... Features... Models. Model List.... Models and Features... Nomenclature... 4 Engineering Information... Installation Guide. Precautions...4. Preparation...4. Installation....4 Lubrication... Dimensional Tables for pherical Roller earing Units XP, ZP... d ~ 4 inch 4 ~ XEP, ZEP...4 d ~ 4 inch 4 ~ X4F, Z4F...4 d ~ 4 inch 4 ~ XE4F, ZE4F...44 d ~ 4 inch 4 ~ X4FC, Z4FC...4 d ~ 4 inch 4 ~ XT, ZT...4 d / ~ inch ~ X4P, Z4P... d / ~ 4 inch ~ XD4P, ZD4P... d / ~ 4 inch ~ X4, Z4...4 d ~ 4 inch 4 ~ XD4, ZD4... d / ~ 4 inch ~

208 tructure and Features tructure and Features. tructure More than sixty years of experience and innovation in the field of mounted ball bearing units has lead to the production of mounted spherical roller units that cater to a wide range of applications and industries. earing and housing production are accomplished entirely by FYH while utilizing only the highest quality materials available. Through meticulous design enhancements and careful material selection this heavy duty mounted roller series attains the designation of EXTR TOUGH.. Features FYH spherical roller bearing units have many features and are available in various models. wide selection of mounted units is offered to fit virtually any application. EXTR TOUGH elf-ligning Double Row pherical Roller earing Our original Triple Lip eal allows up to ± of misalignment Concentric Locking Collars and setscrews at Elongated olt Holes with Two and Four olt Pillow lock Housings One-Piece emi olid ase Ductile Iron Housing

209 Triple Lip eal ± elf ligning capability The triple-lip seal maintains positive contact with a special sealing ring at virtually any angle of shaft misalignment. Our new patent pending sealing design protects the bearing against a variety of wet and dry contaminants and dramatically improves bearing life. The ability to accoodate shaft expansion is also available. emi olid ase One piece ductile iron housings Positive seal contact is maintained during mis-alignment at any angle. Ductile iron housings are approximately twice as strong as cast iron, and the semi-solid base design provides an excellent mounting foundation and superior rigidity over competitive offerings. The standard housing material from FYH is ductile iron, and additional material options may also be available. Lubrication FYH Roller Grease is a calcium sulfonate complex thickened lubricating grease formulated in % synthetic hydrocarbon base oil. FYH Roller Grease has excellent low temperature and high temperature performance, and it provides excellent extreme pressure and anti-wear protection. FYH Roller Grease also provides excellent corrosion protection and water wash-out resistance. Grease temperature range: -4 to 4 F (-4 to C) FYH Roller Grease is also available in automatic lubricators. 4 Designed to Interchange with the Competition Units are designed to interchange with most spherical roller unit footprints. Elongated bolt holes are dimensioned to allow for a shortened or extended mounting pitch to accoodate practically any competitive tapered roller or spherical roller design. Convertible from Non-expansion to Expansion y simply moving a snap ring on the back of the unit the bearing can easily be converted from non-expansion to expansion or vice versa. This procedure can be easily performed in the field even after the unit has been mounted.

210 tructure and Features Locking tyle The patent pending Z-Lock is the first ever tapered bore locking collar system. Just tighten the cap screws properly and the specialized tapered bore collar provides extreme holding power on the shaft without causing any damage. This is a true degree locking mechanism. Disassembly is easily accomplished with two threaded holes in the collar for standard withdrawal dismounting. THE MOT REVOLUTIONRY LOCKING YTEM

211 Models. Model List Table. shows the models of FYH pherical Roller earing Units. Table. FYH pherical Roller earing Units models Model PHERICL ROLLER ERING UNIT PHERICL ROLLER ERING INERT Type haft dia. earing bore dia. urface Model Dimension (inch) () (fixing to shaft) code table min. max. min. max. () -olt ase Pillow lock Units with set screw collar lock XP 4 4 P. with Z-Lock ZP 4 4 P. () -olt ase Type E Pillow Units with set screw collar lock XEP 4 4 P.4 with Z-Lock ZEP 4 4 P.4 () 4-olt Flange Units with set screw collar lock X4F 4 4 P.4 with Z-Lock Z4F 4 4 P.4 (4) 4-olt Type E Flange Units with set screw collar lock XE4F 4 4 P.44 with Z-Lock ZE4F 4 4 P.44 () Flange Cartridge Units with set screw collar lock X4FC 4 4 P.4 with Z-Lock Z4FC 4 4 P.4 () Take-Up Units with set screw collar lock XT / P.4 with Z-Lock ZT / P.4 () 4-olt ase Pillow lock Units with set screw collar lock X4P / 4 P. with Z-Lock Z4P / 4 P. with set screw collar lock (both) XD4P / 4 P. with Z-Lock (both) ZD4P / 4 P. () X Inserts with set screw collar lock X 4 4 P.4 () Z Inserts with Z-Lock Z 4 4 P.4 () XD Inserts with set screw collar lock (both) XD / 4 P. (4) ZD Inserts with Z-Lock (both) ZD / 4 P.

212 Models. Models and Features PHERICL ROLLER ERING UNIT -olt ase Pillow lock Units XP XEP 4-olt Flange Units X4F XE4F Flange Cartridge Units X4FC ZP ZEP Z4F ZE4F Z4FC XP is a two-bolt pillow block unit with a setscrew locking insert system. This unit is equivalent to many of our competitors R style housings. XEP is with Type E mounting dimensions which has a footprint that can accoodate both a tapered roller unit and a spherical roller unit for most shaft sizes. ZP and ZEP have the same housing dimensions as the above styles but utilize our revolutionary Z-Lock concentric locking collar system. X4F is a four-bolt flange unit with set screw locking system. It has standard spherical roller unit mounting dimensions and a compact footprint for areas with limited space. XE4F has Type E mounting dimensions with the same footprint as a tapered roller unit. Z4F and ZE4F have the same housing dimensions as the above units but utilize our revolutionary Z-Lock concentric locking collar system. X4FC is a piloted flange cartridge unit with a setscrew locking insert system. Its pilot mounting dimensions are the same as the medium duty ball bearing units that allow for easy upgrades to a heavier duty series. The threaded withdrawal holes make for quick and easy dismounting. Z4FC carries as the same housing dimensions as the above unit but incorporate the revolutionary Z-Lock concentric locking collar system. 4 Take-Up Units XT is a take-up unit with set screw locking system. It has rail slots that are compatible with many industrial frame sizes. This unit can safely handle high belt tension and heavy shock loads. ZT has the same housing dimensions as the XT units but incorporates the revolutionary Z-Lock concentric locking collar system. XT ZT 4-olt ase Pillow lock Units X4P Z4P X4P is a four-bolt base pillow block unit with standard spherical roller bearing mounting dimensions. Four mounting bolt-holes create a firm and secure fit to the mounting surface. The ends of the housing are flat to allow for mounting inside of a fixed frame assembly. Z4P is the Z-lock equivalent of the X4P carrying the same housing dimensions but utilizing the revolutionary Z-Lock concentric locking collar system.

213 4-olt ase Pillow lock Units (Double Collar) XD4P ZD4P XD4P is the same as the X4P above but utilizes a double lock. This insert has a setscrew locking mechanism on both the front and back of the inner ring. This additional locking mechanism is helpful in applications where the bearing experiences some thrust loads on the inner ring that could cause a single locking unit to slip. ZD4P is the Z-lock equivalent of the XD4P carrying the same housing dimensions but utilizing the revolutionary Z-Lock concentric locking collar system. PHERICL ROLLER ERING INERT pherical Roller earing Inserts (ingle Collar) X Z X is a setscrew locking insert that utilizes the patented ullet Point setscrews at degrees apart to hold shafting firmly in place. This is the most economical type of R insert and can be utilized in a wide variety of industrial and agricultural applications. Z is a concentric locking insert that utilizes a tapered collar that allows for fast mounting while avoiding damage to shafting that a setscrew unit can cause. The tapered collar keeps the % true concentric holding power and does not remove any clearance in the insert by over tightening like the adaptor sleeve locking system can. The unit is tightened down using a hex wrench on the cap screws in a star pattern. The insert can be uninstalled by removing all cap screws and using two of them in the withdrawal holes to disengage the collar. pherical Roller earing Inserts (Double Collar) XD ZD XD is the same as the X above but utilizes a double lock. This insert has a setscrew locking mechanism on both the front and back of the inner ring. This additional locking mechanism is helpful in applications where the bearing experiences some thrust loads on the inner ring that could cause a single locking unit to slip. ZD is the same as the Z above but utilizes a double lock. This insert has a concentric tapered collar on both the front and back of the inner ring. This additional locking mechanism is helpful in applications where a bearing experiences some thrust loads on the inner ring that could cause a single locking unit to slip.

214 Nomenclature Nomenclature The nomenclature of a FYH pherical Roller Unit is comprised of the roller bearing unit model code which is made up using the bearing model code and the housing model code. This in combination with the diameter series code, bore diameter code, accessory code and any special code for individual applications determines the FYH pherical Roller Units part number. X EP 4 - F ** earing No. Housing No. X4- EP EXPNION Type ore ize (inch) Number of / of Inches (ex. = / ) ore ize (base) Metric type x of Number (ex. = ) eries code 4 pherical Roller Housing model code P - olt Pillow lock 4P 4 - olt Pillow lock 4F 4 - olt Flange 4FC Flange Cartridge T Take - Up EP - olt Pillow lock : TYPE E (inch) E4F 4 - olt Flange : TYPE E (inch) INERT- model code pherical Roller T Taper Roller INERT- Locking Type code X et crew Collar Lock XD et crew Collar Lock (Double Collar) Z Z - Lock Concentric Locking ystem 4 Engineering Information pherical Roller earing Life Calculations The relationship between the basic rating life, the basic dynamic load rating, and the dynamic equivalent load of the spherical roller bearing is indicated in Formula. If the spherical roller bearing unit is being used at a fixed rotating speed, the life is indicated as time. This is shown in Formula... Cr L = ( ) Pr Lh = L = Cr ( ) n n Pr L : asic Rating Life rotations Lh : Rated Life (hr) Cr : asic Dynamic Load Rating (lbf) Pr : Dynamic equivalent Load (lbf) n : peed (min ) asic Loads (lbf) ize Code Dynamic Cr tatic Cor X4 44 X X4 X4 X4 4 X4 4 4 X4 4 X4 ize Code Limiting peed for eals tandard Triple Lip eal Limiting peeds (dn=,) RPM Non Contact eal Limiting peeds (dn=,) RPM X4 X4 4 X4 X4 X4 X4 4 X4 44 X4

215 llowable Radial Load (lbf) at Various RPM haft ize / 4 / 4 / ize X4 X4 X4 / X4 / X4 / / X4 / X4 / X4 RPM L hours lue area: The tandard Triple Lip eal is used.. Green area: non-contact seal is used.

216 Installation Guide Installation Guide. Precautions Read the entire installation guide prior to beginning. earings are precision instruments and they must always be handled carefully to prevent damage. tore bearings in a cool and dry location, and always leave bearings in original packaging until ready for installation. earing life calculations should be performed prior to installation to ensure that the selected unit is acceptable for the application. The use of more than two bearings on a single shaft is not recoended. To maximize the life of the bearing avoid mis-alignment and pre-loading by carefully following these instructions. lways lock out the power source and adhere closely to industry safety standards before performing any work on the equipment.. Preparation The mounting surface and housing base must be clean, flat, and of sufficient thickness to support the weight of the entire assembly without deflecting or breaking. Make sure that the mounting surface is parallel to the plane of the shaft for pillow blocks, and perpendicular to the shaft for flanges and take-up units. FYH mounted bearings can accoodate up to ± degrees of mis-alignment, however longer bearing life can be achieved if mis-alignment can be minimized during installation. Check the shaft diameter and make sure that it is within tolerance as indicated in Table. Check that the shaft is straight, clean, and free of burrs or other imperfections. Use emery cloth or a fine file to smooth the surface as necessary. small amount of lubricant may be applied to both the shaft and the bore of the bearing; however lubricant should not be applied to the areas where the bearing locking mechanism contacts the shaft. To ensure adequate locking power between the bearing and shaft the hardness of the shaft should not exceed Rc 4. haft ize () h Table - haft Tolerance haft peed Greater Than % of Max RPM Rating h haft peed Less Than % of Max RPM Rating Over Incl. Max () Min () Max () Min () Converting units from fixed to expansion FYH mounted roller units are capable of operating in both a fixed or expansion configuration. efore bearing installation On the back side of the unit (opposite the housing markings), remove the bearing retaining ring located on the inner diameter of the housing and move it back to the groove on the outer position of the housing. lide the bearing insert rearward within the housing until it sits against the retaining ring that was just relocated. When ready for installation, slide the insert forward in the housing approximately one thirty-second of an inch ( ) and alternately tighten the set screws onto the shaft to the specified torque setting as shown in Table 4. fter bearing installation efore performing any work on the bearing, lock out the power source and allow the shaft and adjacent machinery to cool down to ambient temperature. Loosen the set screws or other locking mechanism to allow the shaft to move freely within the bore then follow the same procedures explained in the efore bearing installation section. 4

217 . Installation. lide the unit onto the shaft while holding the inner ring of the Table - Mounting olt Tightening Torque bearing. olt ize Tightening Torque Position the unit on the mounting surface so that the plane of inch N-m in-lbf ft-lbf the shaft is perpendicular to the face of the housing, and M 4 4 alternately tighten the mounting bolts to the specified torque M / as shown in Table. M Make sure to use bolts, washers, and nuts of sufficient strength M 4 and grade rating for the application. M 4 M. Check the final position of the shaft and alternately tighten the M 4 set screws of the non-expansion unit onto the shaft to the M specified torque setting as shown in Table. The set screws in M 44 4 the bearing on the opposite side of the shaft should line up with the set screws of the bearing that was installed first (ee Figure ). Expansion bearings should be installed only after the shaft and adjacent machinery has cooled down to the ambient temperature. fter positioning the expansion unit on the shaft slide the insert to the rearmost position within the housing until it seats against the retaining ring. Then slide the insert forward in the housing approximately one thirty second of an inch ( ) and alternately tighten the set screws onto the shaft to the specified torque setting as shown in Table. llowable shaft expansion and expansion calculation data can be found in Table 4 and Formula respectively.. Once installed, slowly rotate the bearing by hand to confirm that it turns smoothly and without resistance, vibration, or any other abnormalities. Table - et crew Tightening Torque Table 4 - llowable haft Expansion ize Code et crew ize N-m in-lbf ft-lbf ize Code inch X4 X4 /- UNF x 4. X4 X4 X4 X4 X4-4 UNF x. X4 X4 X4 X4 X4 X4 - UNF x. 4 X4 X4 X4 Formula Linear haft Expansion Figure et crews Lined Up in oth earings L = T D L : Expansion of shaft () : Linear expansion coefficient of shaft for ordinary steel (. x ) T : Temperature increase (ºC) D : Installation distance between bearing units () VIDEO ON INTLLTION Please scan the QR code with your mobile phone and watch an installation video. If you don t have the reader, get the QR Reader app at the app store. Or you can find it at our website as well.

218 Installation Guide.4 Lubrication Proper lubrication practices will greatly extend the life of the bearing. earings are factory lubricated with the proper amount and type of lubricant for most general purpose applications as well as many highly demanding operating environments, and except as recoended by FYH, no further lubrication is required upon installation. Lubrication tips: The factory standard lubricant is a Calcium ulfonate grease. lways use the same type of lubricant to avoid compatibility issues and other potential problems. When adding lubricant do so slowly and while the bearing is rotating until a small amount of lubricant can be seen coming out of the seals. t low speeds (below RPM) it is acceptable to completely fill the bearing with grease. t moderate to high speeds it is not advisable to completely fill the bearing with grease as it could lead to overheating and reduced bearing life. It is generally better to use less lubrication more frequently than more lubricant less often. If the unit will not be operated for an extended period of time extra lubricant should be added to prevent corrosion. If the unit has not been operated for an extended period of time fresh lubricant should be added prior to start-up. If the unit becomes too hot during operation from over-lubrication remove the grease fitting and operate the unit for approximately thirty minutes to allow excess grease to purge. ppropriate lubrication intervals can be determined by referring to Table ; however experience should largely determine the actual lubrication regimen for a particular application. Consult with an FYH representative for assistance. If a suitable Calcium ulfonate lubricant is not available for re-lubrication then the following compatible lubricants may also be used: arium Complex, Calcium tearate, Lithium Complex, Polyurea (hear table) The use of any other type of lubricant should be avoided to prevent compatibility issues with the Calcium ulfonate grease that is originally supplied. To find the proper lubrication interval in Table obtain the relevant percentage of max allowable RPM by referring to Table. Example: X4 with positive contact seals has a max RPM rating of. If the application has an RPM of then the percentage of max RPM is % ( =.). The amount of grease for replenishment can be found in Table. Table - Lubrication chedule Environment Clean to Moderately Dirty Clean to Moderately Dirty Temperature ( C) % of max allowable RPM Lubrication interval Under degrees Over degrees Dirty to Very Dirty From - to - % - % - % - % - % - % - % - % From three to eight months From one to three months From one week to one month Daily to once per week From two to six weeks From one week to one month Daily to once per week Daily to once per week

219 Table - Limiting peed for eals Table - Grease mount for Replenishment ize Code tandard Triple Lip eal Limiting Non Contact eal Limiting ize Code mount of Grease (grams) X4 X4 - X4 4 X4 - X4 X4 - X4 X4 - X4 X4 - X4 4 X4 - X4 44 X4 4-4 X4 X4 -

220 -olt ase Pillow lock Units XP Cylindrical bore (with set screw collar lock) d ~ 4 inch 4 ~ ZP Cylindrical bore (with Z-Lock) d ~ 4 inch 4 ~ N N N N H H H H H H J L J L haft Dia. Dimensions Unit earing Unit earing olt inch inch No. No. No. No. ize inch d H L J N N H H / 4 / 4 / / / / / / / / / 4 4 / / 4 / / / / 44 / / /... / XP4- XP4- XP4-4 XP4 XP4- XP4- XP4 XP4- XP4 XP4- XP4 XP4- XP4- XP4 XP4- XP4-4 XP4 XP44 XP4-4 XP4-44 XP4-4 XP4 XP4-4 XP4 XP4- XP4 XP4- XP4- XP4 XP4 XP4- XP4-4 X4- X4- X4-4 X4 X4- X4- X4 X4- X4 X4- X4 X4- X4- X4 X4- X4-4 X4 X44 X4-4 X4-44 X4-4 X4 X4-4 X4 X4- X4 X4- X4- X4 X4 X4- X4-4 ZP4- ZP4- ZP4-4 ZP4 ZP4- ZP4- ZP4 ZP4- ZP4 ZP4- ZP4 ZP4- ZP4- ZP4 ZP4- ZP4-4 ZP4 ZP44 ZP4-4 ZP4-44 ZP4-4 ZP4 ZP4-4 ZP4 ZP4- ZP4 ZP4- ZP4- ZP4 ZP4 ZP4- ZP4-4 Z4- Z4- Z4-4 Z4 Z4- Z4- Z4 Z4- Z4 Z4- Z4 Z4- Z4- Z4 Z4- Z4-4 Z4 Z44 Z4-4 Z4-44 Z4-4 Z4 Z4-4 Z4 Z4- Z4 Z4- Z4- Z4 Z4 Z4- Z4-4 M M M M M M M M

221 -olt ase Type E Pillow lock Units XEP Cylindrical bore (with set screw collar lock) d ~ 4 inch 4 ~ ZEP Cylindrical bore (with Z-Lock) d ~ 4 inch 4 ~ N N H N H N H H H H J L J L haft Dia. Dimensions Unit earing Unit earing olt inch inch No. No. No. No. ize inch d H L J N N H H / 4 / 4 / / / / / / / / 4 4 / / / / 4 / / / 4 / 4 44 / / /... / XEP4- XEP4- XEP4-4 XEP4 XEP4- XEP4- XEP4 XEP4- XEP4 XEP4- XEP4 XEP4- XEP4- XEP4 XEP4- XEP4-4 XEP4 XEP44 XEP4-4 XEP4-44 XEP4-4 XEP4 XEP4-4 XEP4 XEP4- XEP4 XEP4- XEP4- XEP4 XEP4 XEP4- XEP4-4 X4- X4- X4-4 X4 X4- X4- X4 X4- X4 X4- X4 X4- X4- X4 X4- X4-4 X4 X44 X4-4 X4-44 X4-4 X4 X4-4 X4 X4- X4 X4- X4- X4 X4 X4- X4-4 ZEP4- ZEP4- ZEP4-4 ZEP4 ZEP4- ZEP4- ZEP4 ZEP4- ZEP4 ZEP4- ZEP4 ZEP4- ZEP4- ZEP4 ZEP4- ZEP4-4 ZEP4 ZEP44 ZEP4-4 ZEP4-44 ZEP4-4 ZEP4 ZEP4-4 ZEP4 ZEP4- ZEP4 ZEP4- ZEP4- ZEP4 ZEP4 ZEP4- ZEP4-4 Z4- Z4- Z4-4 Z4 Z4- Z4- Z4 Z4- Z4 Z4- Z4 Z4- Z4- Z4 Z4- Z4-4 Z4 Z44 Z4-4 Z4-44 Z4-4 Z4 Z4-4 Z4 Z4- Z4 Z4- Z4- Z4 Z4 Z4- Z4-4 M M M M M M M M 4 4

222 4 - olt Flange Units X4F Cylindrical bore (with set screw collar lock) d ~ 4 inch 4 ~ L J 4-φN Z4F Cylindrical bore (with Z-Lock) d ~ 4 inch 4 ~ L J 4-φN L J L J haft Dia. Dimensions Unit earing Unit earing olt inch inch No. No. No. No. ize inch d L J N / 4 / 4 / / / / / / / 4 4 / /.. 4 / / / X4F4- X4F4- X4F4-4 X4F4 X4F4- X4F4- X4F4 X4F4- X4F4 X4F4- X4F4 X4F4- X4F4- X4F4 X4F4- X4F4-4 X4F4 X4F44 X4F4-4 X4F4-44 X4F4-4 X4F4 X4F4-4 X4F4 X4F4- X4F4 X4F4- X4F4- X4F4 X4F4 X4F4- X4F4-4 X4- X4- X4-4 X4 X4- X4- X4 X4- X4 X4- X4 X4- X4- X4 X4- X4-4 X4 X44 X4-4 X4-44 X4-4 X4 X4-4 X4 X4- X4 X4- X4- X4 X4 X4- X4-4 Z4F4- Z4F4- Z4F4-4 Z4F4 Z4F4- Z4F4- Z4F4 Z4F4- Z4F4 Z4F4- Z4F4 Z4F4- Z4F4- Z4F4 Z4F4- Z4F4-4 Z4F4 Z4F44 Z4F4-4 Z4F4-44 Z4F4-4 Z4F4 Z4F4-4 Z4F4 Z4F4- Z4F4 Z4F4- Z4F4- Z4F4 Z4F4 Z4F4- Z4F4-4 Z4- Z4- Z4-4 Z4 Z4- Z4- Z4 Z4- Z4 Z4- Z4 Z4- Z4- Z4 Z4- Z4-4 Z4 Z44 Z4-4 Z4-44 Z4-4 Z4 Z4-4 Z4 Z4- Z4 Z4- Z4- Z4 Z4 Z4- Z4-4 M M M M M M M M 4 4

223 4 - olt Type E Flange Units XE4F Cylindrical bore (with set screw collar lock) d ~ 4 inch 4 ~ L J 4-φN ZE4F Cylindrical bore (with Z-Lock) d ~ 4 inch 4 ~ L J 4-φN L J L J haft Dia. Dimensions Unit earing Unit earing olt inch inch No. No. No. No. ize inch d L J N / 4 / 4 / / / / / / / / / / / / / / 4 4. /... 4 /. 4 / / XE4F4- XE4F4- XE4F4-4 XE4F4 XE4F4- XE4F4- XE4F4 XE4F4- XE4F4 XE4F4- XE4F4 XE4F4- XE4F4- XE4F4 XE4F4- XE4F4-4 XE4F4 XE4F44 XE4F4-4 XE4F4-44 XE4F4-4 XE4F4 XE4F4-4 XE4F4 XE4F4- XE4F4 XE4F4- XE4F4- XE4F4 XE4F4 XE4F4- XE4F4-4 X4- X4- X4-4 X4 X4- X4- X4 X4- X4 X4- X4 X4- X4- X4 X4- X4-4 X4 X44 X4-4 X4-44 X4-4 X4 X4-4 X4 X4- X4 X4- X4- X4 X4 X4- X4-4 ZE4F4- ZE4F4- ZE4F4-4 ZE4F4 ZE4F4- ZE4F4- ZE4F4 ZE4F4- ZE4F4 ZE4F4- ZE4F4 ZE4F4- ZE4F4- ZE4F4 ZE4F4- ZE4F4-4 ZE4F4 ZE4F44 ZE4F4-4 ZE4F4-44 ZE4F4-4 ZE4F4 ZE4F4-4 ZE4F4 ZE4F4- ZE4F4 ZE4F4- ZE4F4- ZE4F4 ZE4F4 ZE4F4- ZE4F4-4 Z4- Z4- Z4-4 Z4 Z4- Z4- Z4 Z4- Z4 Z4- Z4 Z4- Z4- Z4 Z4- Z4-4 Z4 Z44 Z4-4 Z4-44 Z4-4 Z4 Z4-4 Z4 Z4- Z4 Z4- Z4- Z4 Z4 Z4- Z4-4 M M M M M M M M 44 4

224 Flange Cartridge Units X4FC Cylindrical bore (with set screw collar lock) d ~ 4 inch 4 ~ 4-φN -M Z4FC Cylindrical bore (with Z-Lock) d ~ 4 inch 4 ~ 4-φN -M φh L J φh L J J J C C haft Dia. Dimensions Unit earing Unit earing olt inch inch No. No. No. No. ize inch d L H J J N C M / 4 / 4 / / / / / / / / 4 / /..... / / 4 / 4 /.. / 4. / 4... / / UNC. /-4UNC. /-4UNC. -UNC /.4 -UNC 4. -UNC 4. -UNC 4 /. -UNC X4FC4- X4FC4- X4FC4-4 X4FC4 X4FC4- X4FC4- X4FC4 X4FC4- X4FC4 X4FC4- X4FC4 X4FC4- X4FC4- X4FC4 X4FC4- X4FC4-4 X4FC4 X4FC44 X4FC4-4 X4FC4-44 X4FC4-4 X4FC4 X4FC4-4 X4FC4 X4FC4- X4FC4 X4FC4- X4FC4- X4FC4 X4FC4 X4FC4- X4FC4-4 X4- X4- X4-4 X4 X4- X4- X4 X4- X4 X4- X4 X4- X4- X4 X4- X4-4 X4 X44 X4-4 X4-44 X4-4 X4 X4-4 X4 X4- X4 X4- X4- X4 X4 X4- X4-4 Z4FC4- Z4FC4- Z4FC4-4 Z4FC4 Z4FC4- Z4FC4- Z4FC4 Z4FC4- Z4FC4 Z4FC4- Z4FC4 Z4FC4- Z4FC4- Z4FC4 Z4FC4- Z4FC4-4 Z4FC4 Z4FC44 Z4FC4-4 Z4FC4-44 Z4FC4-4 Z4FC4 Z4FC4-4 Z4FC4 Z4FC4- Z4FC4 Z4FC4- Z4FC4- Z4FC4 Z4FC4 Z4FC4- Z4FC4-4 Z4- Z4- Z4-4 Z4 Z4- Z4- Z4 Z4- Z4 Z4- Z4 Z4- Z4- Z4 Z4- Z4-4 Z4 Z44 Z4-4 Z4-44 Z4-4 Z4 Z4-4 Z4 Z4- Z4 Z4- Z4- Z4 Z4 Z4- Z4-4 M M M M M M M M 4 4

225 Take - Up Units XT Cylindrical bore (with set screw collar lock) d / ~ inch ~ L ZT Cylindrical bore (with Z-Lock) d / ~ inch ~ L H H H N φn H H H N φn L N L N L L L L haft Dia. Dimensions Unit earing Unit earing inch inch No. No. No. No. d H H H L L L L N N N / / / / / / / / / /. /. / / 4 / / /. / / /. /.4.4 /. / /. /. /.. / / XT4- XT4 XT4- XT4 XT4- XT4- XT4 XT4- XT4-4 XT4 XT44 XT4-4 XT4-44 XT4-4 XT4 XT4-4 XT4 XT4- XT4 XT4- XT4- XT4 X4- X4 X4- X4 X4- X4- X4 X4- X4-4 X4 X44 X4-4 X4-44 X4-4 X4 X4-4 X4 X4- X4 X4- X4- X4 ZT4- ZT4 ZT4- ZT4 ZT4- ZT4- ZT4 ZT4- ZT4-4 ZT4 ZT44 ZT4-4 ZT4-44 ZT4-4 ZT4 ZT4-4 ZT4 ZT4- ZT4 ZT4- ZT4- ZT4 Z4- Z4 Z4- Z4 Z4- Z4- Z4 Z4- Z4-4 Z4 Z44 Z4-4 Z4-44 Z4-4 Z4 Z4-4 Z4 Z4- Z4 Z4- Z4- Z4 4 4

226 4-olt ase Pillow lock Units X4P Cylindrical bore (with set screw collar lock) d / ~ 4 inch ~ Z4P Cylindrical bore (with Z-Lock) d / ~ 4 inch ~ N N N N E E N H N H N N H H H H J L J L haft Dia. Dimensions Unit earing Unit earing olt inch inch No. No. No. No. ize inch d H L J N N E H H / / / / / / / 4 / 4 / / / 4 / X4P4 X4P4- X4P4-4 X4P4 X4P44 X4P4-4 X4P4-44 X4P4-4 X4P4 X4P4-4 X4P4 X4P4- X4P4 X4P4- X4P4- X4P4 X4P4 X4P4- X4P4-4 X4 X4- X4-4 X4 X44 X4-4 X4-44 X4-4 X4 X4-4 X4 X4- X4 X4- X4- X4 X4 X4- X4-4 Z4P4 Z4P4- Z4P4-4 Z4P4 Z4P44 Z4P4-4 Z4P4-44 Z4P4-4 Z4P4 Z4P4-4 Z4P4 Z4P4- Z4P4 Z4P4- Z4P4- Z4P4 Z4P4 Z4P4- Z4P4-4 Z4 Z4- Z4-4 Z4 Z44 Z4-4 Z4-44 Z4-4 Z4 Z4-4 Z4 Z4- Z4 Z4- Z4- Z4 Z4 Z4- Z4-4 M M M M

227 4-olt ase Pillow lock Units XD4P Cylindrical bore (with set screw collar lock) d / ~ 4 inch ~ ZD4P Cylindrical bore (with Z-Lock) d / ~ 4 inch ~ N N N N E E N H N H N N H H H H J L J L haft Dia. Dimensions Unit earing Unit earing olt inch inch No. No. No. No. ize inch d H L J N N E H H / / / / / / / 4 / 4 / / / 4 / XD4P4 XD4P4- XD4P4-4 XD4P4 XD4P44 XD4P4-4 XD4P4-44 XD4P4-4 XD4P4 XD4P4-4 XD4P4 XD4P4- XD4P4 XD4P4- XD4P4- XD4P4 XD4P4 XD4P4- XD4P4-4 XD4 XD4- XD4-4 XD4 XD44 XD4-4 XD4-44 XD4-4 XD4 XD4-4 XD4 XD4- XD4 XD4- XD4- XD4 XD4 XD4- XD4-4 ZD4P4 ZD4P4- ZD4P4-4 ZD4P4 ZD4P44 ZD4P4-4 ZD4P4-44 ZD4P4-4 ZD4P4 ZD4P4-4 ZD4P4 ZD4P4- ZD4P4 ZD4P4- ZD4P4- ZD4P4 ZD4P4 ZD4P4- ZD4P4-4 ZD4 ZD4- ZD4-4 ZD4 ZD44 ZD4-4 ZD4-44 ZD4-4 ZD4 ZD4-4 ZD4 ZD4- ZD4 ZD4- ZD4- ZD4 ZD4 ZD4- ZD4-4 M M M M

228 pherical Roller earing Inserts X4 Cylindrical bore (with set screw collar lock) d ~ 4 inch 4 ~ C Z4 Cylindrical bore (with Z-Lock) C XD4 Cylindrical bore (with set screw collar lock (both)) d / ~ 4 inch ~ C ZD4 Cylindrical bore (with Z-Lock (both)) C φd φd φd φd haft Dia. Dimensions earing earing inch inch No. No. d C D haft Dia. Dimensions earing earing inch inch No. No. d C D / 4 / 4 / / / / / / / 4 / 4 / 4 / / 4 / X4- X4- X4-4 X4 X4- X4- X4 X4- X4 X4- X4 X4- X4- X4 X4- X4-4 X4 X44 X4-4 X4-44 X4-4 X4 X4-4 X4 X4- X4 X4- X4- X4 X4 X4- X4-4 Z4- Z4- Z4-4 Z4 Z4- Z4- Z4 Z4- Z4 Z4- Z4 Z4- Z4- Z4 Z4- Z4-4 Z4 Z44 Z4-4 Z4-44 Z4-4 Z4 Z4-4 Z4 Z4- Z4 Z4- Z4- Z4 Z4 Z4- Z4-4 / / / / / / XD4 XD4- XD4-4 XD4 XD44 XD4-4 XD4-44 XD4-4 XD4 XD4-4 XD4 XD4- XD4 XD4- XD4- XD4 XD4 XD4- XD4-4 ZD4 ZD4- ZD4-4 ZD4 ZD44 ZD4-4 ZD4-44 ZD4-4 ZD4 ZD4-4 ZD4 ZD4- ZD4 ZD4- ZD4- ZD4 ZD4 ZD4- ZD4-4 4

229

General Bearings BALL BEARING UNITS

General Bearings BALL BEARING UNITS General earings LL ERING UNIT all earing Units (contents) Technical section tructure and features... Unit number... Types... 4 election of unit... Life of bearing... earing load... llowable rotational

More information

NU Concentric-LOC BALL BEARING UNITS

NU Concentric-LOC BALL BEARING UNITS NU Concentric-OC B BERING UNIT CTOG NO. EY INTTION HFT CONTCT TRUE CONCENTRIC OCK The FYH NU-OC bearing grips the shaft more uniformly, which allows degrees of equalized locking contact. The roundness

More information

MOLINE PRODUCT LINE -BOLT PILLOW BLOCK 4-BOLT PILLOW BLOCK 4-BOLT FLANGE PILOTED FLANGE TYPE E TAPERED ROLLER BEARINGS -Bolt Pillow Block: shaft sizes

MOLINE PRODUCT LINE -BOLT PILLOW BLOCK 4-BOLT PILLOW BLOCK 4-BOLT FLANGE PILOTED FLANGE TYPE E TAPERED ROLLER BEARINGS -Bolt Pillow Block: shaft sizes PRODUCT LINE MOLINE PRODUCT LINE -BOLT PILLOW BLOCK 4-BOLT PILLOW BLOCK 4-BOLT FLANGE PILOTED FLANGE TYPE E TAPERED ROLLER BEARINGS -Bolt Pillow Block: shaft sizes from, 5mm 90mm 4-Bolt Pillow Block: shaft

More information

UC-SERIES TIMKEN BALL BEARING HOUSED UNITS

UC-SERIES TIMKEN BALL BEARING HOUSED UNITS UC-SERIES TIMKEN BALL BEARING HOUSED UNITS UC-SERIES TIMKEN BALL BEARING HOUSED UNITS Introduction...3 Features...4 Housing Styles...5 Nomenclature...6 Technical Data...7 Installation...4 HOUSED UNIT TABLES

More information

Set screw mounted ball bearings

Set screw mounted ball bearings Features/Benefits For over 70 years, Dodge has been talking to mounted bearing users and listening to their needs. This experience lead to the design of the optimum mounted ball bearing. A state-of-the-art

More information

CONTENTS. Setscrew Ball Bearings

CONTENTS. Setscrew Ball Bearings CONTENTS Features / Benefits... B4-3 How to Order / Nomenclature... B4-5 Selection... B4-6 Selection/Dimensions Pillow Blocks SC - Normal Duty... B4-12 SCAH Air Handling Normal Duty... B4-16 SCB Normal

More information

FEATURES/BENEFITS. Setscrew Ball Bearings. DODGE End Covers

FEATURES/BENEFITS. Setscrew Ball Bearings. DODGE End Covers or over 70 years, DODGE has been talking to mounted bearing users and listening to their needs. This experience lead to the design of the optimum mounted ball bearing. A state-of-the-art facility was built

More information

SKF ball bearing units UC range. Japanese Industrial Standards compliant ball bearing units

SKF ball bearing units UC range. Japanese Industrial Standards compliant ball bearing units SKF ball bearing units UC range Japanese Industrial Standards compliant ball bearing units Solid design, solid benefits In order to meet the industry s demands of improved protection against contaminant

More information

Extreme Duty mounted ball bearings

Extreme Duty mounted ball bearings 3-2 ABB Mounted bearings Metric Features/Benefits The Dodge SC/SCMED Extreme Duty ball bearing offers extended life in the toughest industrial applications. Incorporating patented Dodge-only features such

More information

114 NOSE SEIKO CO.,LTD NOSE SEIKO CO.,LTD

114 NOSE SEIKO CO.,LTD NOSE SEIKO CO.,LTD 114 NOSE SEIKO CO.,LTD NOSE SEIKO CO.,LTD 115 and Part Code Applicable axis diameter Feature Part Code 5 ~ 3 General purpose cam follower with screwdriver groove on the stud head. Available with stainless

More information

Product Brochure. E-Z Kleen and Ultra Kleen ball bearings

Product Brochure. E-Z Kleen and Ultra Kleen ball bearings Product Brochure E-Z Kleen and Ultra Kleen ball bearings We provide motors, generators and mechanical power transmission products, services and expertise to save energy and improve customers, processes

More information

CONTENTS. D-LOK Ball Bearings

CONTENTS. D-LOK Ball Bearings CONTENTS Ball Bearings Features/Benefits.................................................. B5-2 How to Order/Nomenclature......................................... B5-4 Selection........................................................

More information

Bearing Handling. 15. Bearing Handling Bearing storage Installation

Bearing Handling. 15. Bearing Handling Bearing storage Installation 15. Bearing Handling Bearings are precision parts and, in order to preserve their accuracy and reliability, care must be exercised in their handling. In particular, bearing cleanliness must be maintained,

More information

DODGE E-Z KLEEN and ULTRa KLEEN BaLL BEaRiNGs

DODGE E-Z KLEEN and ULTRa KLEEN BaLL BEaRiNGs DODGE E-Z KLEEN and ULTRA KLEEN Ball Bearings DODGE E-Z KLEEN an d ULTRA KLEEN Ba l l Bear ings For over 125 years, the DODGE brand has been synonymous with the best the industry has to offer. Bearing

More information

Classification and Characteristics of Rolling Bearings

Classification and Characteristics of Rolling Bearings 1. Classification Characteristics of Rolling Beas 1.1 Rolling bea construction Most rolling consist of s with raceway (inner outer ), rolling elements (either balls or rollers) cage. The cage separates

More information

SNN SPLIT PLUMMER BLOCKS

SNN SPLIT PLUMMER BLOCKS SNN SPLIT PLUMMER BLOCKS SNN SPLIT PLUMMER BLOCKS FROM NSK The SNN split plummer block from NSK combines quality materials and design to maximize bearing performance. With features like serialized cap

More information

15. Bearing Handling Storage Fitting A-97

15. Bearing Handling Storage Fitting A-97 15. Bearing Handling Bearings are precision parts, and in order to preserve their accuracy and reliability, care must be exercised in their handling. In particular, bearing cleanliness must be maintained,

More information

CATALOG

CATALOG www.craft-bearings.com CATALOG The contents of this catalog are subjected to change without prior notice. Every possible effort has been made to ensure that the data here in is correct; however, CRAFT

More information

Marathon series corrosion resistant products

Marathon series corrosion resistant products Marathon series corrosion resistant products Contents 2 Introduction 6 End covers 8 Composite units 22 Stainless steel take-up frames 24 Cast stainless steel units 28 ZMaRC-coated insert bearings Stainless

More information

SPHERICAL ROLLER BEARING UNITS

SPHERICAL ROLLER BEARING UNITS SPERIC ROER ERIG UITS fyhbear i ng s.c om.0 CTOG O.b EXTR TOUG omenclature The nomenclature of a FY Spherical Roller Unit is comprised of the roller bearing unit model code which is made up using the bearing

More information

TIMKEN SNT SPLIT PLUMMER BLOCKS

TIMKEN SNT SPLIT PLUMMER BLOCKS TIMKEN SNT SPLIT PLUMMER BLOCKS TIMKEN SNT SPLIT PLUMMER BLOCKS 1 TABLE OF CONTENTS INTRODUCTION... 3 TIMKEN SNT SPLIT PLUMMER BLOCKS...4 SEAL OPTIONS AND DESCRIPTIONS...6 SEAL SELECTION AND CONFIGURATION

More information

Triple-Sealed Bearings for Bearing Units

Triple-Sealed Bearings for Bearing Units For New Technology Network corporation R Triple-Sealed Bearings for Bearing Units @ NTN Triple-Sealed Bearings for Bearing Units These reliable triple-sealed bearings are dustproof and waterproof. They

More information

CONTENTS. GRIP TIGHT Adapter Ball Bearings

CONTENTS. GRIP TIGHT Adapter Ball Bearings CONTENTS GRIP TIGHT Adapter Ball Bearings Features / Benefits.................................................... B2-2 How to Order / Nomenclature............................................ B2-4 Selection............................................................

More information

Split Pillow Block Housings & Accessories

Split Pillow Block Housings & Accessories Split Pillow Block Housings & Accessories TABLE OF CONTENTS How to Order and Seal Types for SNN. 2 How to Order and Seal Types for SAFD...3 Features and Benefits of SNN and SAFD. 4 Clearance Adjustment

More information

HOW TO ORDER/ NOMENCLATURE

HOW TO ORDER/ NOMENCLATURE HOW TO ORDER/ Setscrew Ball Bearings - Inch HOW TO ORDER There are two ways to specify DODGE Bearings. Most of the product offering have part numbers with listings shown throughout this catalog. Use of

More information

Installation Procedures

Installation Procedures For the precision ball and roller bearings supplied by MRC Bearings, skill and cleanliness while handling, mounting and dismounting are necessary to ensure satisfactory bearing performance. As precision

More information

Spherical Roller Bearings Units: Rexnord PT Select Series

Spherical Roller Bearings Units: Rexnord PT Select Series Spherical Roller earings Units: Rexnord PT Select Series Contents Page eatures and enefits 192 Nomenclature 193 Engineering 194 Dimensions Pillow locks 198 lange locks 202 Industries Served Aggregates

More information

INSTRUCTION MANUAL FOR DODGE SAF-XT & SAFS Pillow Blocks All Sizes 1 15 / 16 " through 10 1 / 2 " 2 and 4 Bolt Base

INSTRUCTION MANUAL FOR DODGE SAF-XT & SAFS Pillow Blocks All Sizes 1 15 / 16  through 10 1 / 2  2 and 4 Bolt Base INSTRUCTION MANUAL FOR DODGE SAF-XT & SAFS Pillow Blocks All Sizes 1 15 / 16 " through 10 1 / 2 " 2 and 4 Bolt Base WARNING: Because of the possible danger to person(s) or property from accidents which

More information

CYLINDRICAL ROLLER BEARING CATALOG TIMKEN SMALL BORE METRIC SEALS CATALOG

CYLINDRICAL ROLLER BEARING CATALOG TIMKEN SMALL BORE METRIC SEALS CATALOG CYLINDRICAL ROLLER BEARING CATALOG ABOUT THE TIMKEN COMPANY The leading authority on tapered roller bearings, Timken today applies its deep knowledge of metallurgy, tribology and mechanical power transmission

More information

CONTENTS. Speciality Tapered Products

CONTENTS. Speciality Tapered Products CONTENTS Products Features / Benefi ts Type C............................................................ B7-2 Special Duty, Hinged Cap............................................... B7-3 All Steel............................................................

More information

EPT Mounted Bearing Technical Support. Phone: FAX: Mounted Bearing Application Engineering

EPT Mounted Bearing Technical Support. Phone: FAX: Mounted Bearing Application Engineering ENGINEERING EPT Mounted Bearing Technical Support Browning Technical Services Phone: 606-564-2093 FAX: 606-564-2079 Mounted Bearing Application Phone: 219-465-2211 FAX: 219-465-2290 E-mail: browningbearing.eng@emerson-ept.com

More information

FEATURES/BENEFITS. Type E-Xtra DODGE Type E One Bearing, One Seal For Dusty or Damp Environments

FEATURES/BENEFITS. Type E-Xtra DODGE Type E One Bearing, One Seal For Dusty or Damp Environments Type E-Xtra DODGE Type E One Bearing, One Seal For Dusty or Damp Environments The Original DODGE Type E Bearing, Only Better New Dodge manufactured bearings increase load ratings 13-14% depending on size

More information

B L PRECISION BEARINGS RADIAL BALL & M O U N T E D U N IT CATALOG

B L PRECISION BEARINGS RADIAL BALL & M O U N T E D U N IT CATALOG Catalog No. 0810 Section 1 Deep Groove Ball Bearings Features.............................................2 6000 Series Radial Ball Bearings Extra Light Duty.......................................4 6200

More information

SPHERICAL ROLLER BEARING UNITS

SPHERICAL ROLLER BEARING UNITS SPHERICA ROER BEARING UNITS CATAOG NO.2020 EXTRA TOUGH 2 2 4 Nomenclature The nomenclature of a FYH Spherical Roller Unit is comprised of the roller bearing unit model code which is made up using the bearing

More information

CLASSIFICATION OF ROLLING-ELEMENT BEARINGS

CLASSIFICATION OF ROLLING-ELEMENT BEARINGS CLASSIFICATION OF ROLLING-ELEMENT BEARINGS Ball bearings can operate at higher speed in comparison to roller bearings because they have lower friction. In particular, the balls have less viscous resistance

More information

Product Brochure. Setscrew mounted ball bearings

Product Brochure. Setscrew mounted ball bearings Product Brochure Setscrew mounted ball bearings 2 ABB Motors and Generators Setscrew mounted ball bearings We provide motors, generators and mechanical power transmission products, services and expertise

More information

DODGE USN 500 and 600 Series Adapter Mount & 200 and 300 Series Direct Mount Plummer Blocks

DODGE USN 500 and 600 Series Adapter Mount & 200 and 300 Series Direct Mount Plummer Blocks DODGE USN 500 and 600 Series Adapter Mount & 200 and 300 Series Direct Mount Plummer Blocks These instructions should be read thoroughly before installation or operation. GENERAL INFORMATION WARNING: To

More information

Chapter 11 Rolling Contact Bearings

Chapter 11 Rolling Contact Bearings Chapter 11 Rolling Contact Bearings 1 2 Chapter Outline Bearing Types Bearing Life Bearing Load Life at Rated Reliability Bearing Survival: Reliability versus Life Relating Load, Life, and Reliability

More information

FUNCTION OF A BEARING

FUNCTION OF A BEARING Bearing FUNCTION OF A BEARING The main function of a rotating shaft is to transmit power from one end of the line to the other. It needs a good support to ensure stability and frictionless rotation. The

More information

BROWNING offers a broad and complete line of mounted roller bearing products to satisfy a large variety of rugged, industrial applications.

BROWNING offers a broad and complete line of mounted roller bearing products to satisfy a large variety of rugged, industrial applications. ROLLER BEARINGS Roller Bearing Family of Products BROWNING offers a broad and complete line of mounted roller bearing products to satisfy a large variety of rugged, industrial applications. Browning roller

More information

FAG Cylindrical Roller Bearings full complement Standards Basic designs Tolerances Bearing clearance

FAG Cylindrical Roller Bearings full complement Standards Basic designs Tolerances Bearing clearance FAG Cylindrical Roller earings full complement FAG Cylindrical Roller earings full complement Standards asic designs Tolerances earing clearance Full complement cylindrical roller bearings are suitable

More information

3. BEARING ARRANGEMENT DESIGN

3. BEARING ARRANGEMENT DESIGN 3. BEARING ARRANGEMENT DESIGN 3.1 GENERAL PRINCIPLES OF ROLLING BEARING ARRANGEMENT DESIGN Rotating shaft or another component arranged in rolling bearings is guided by them in radial as well as in axial

More information

Features And Benefits.IMPERIAL... B14-2.IMPERIAL-IP... B14-4.IMPERIAL-HD... B14-6 ISAF-HYD... B14-10.ISN / ISNX-HYD... B14-12

Features And Benefits.IMPERIAL... B14-2.IMPERIAL-IP... B14-4.IMPERIAL-HD... B14-6 ISAF-HYD... B14-10.ISN / ISNX-HYD... B14-12 CONTENTS - IP, ISAF and ISN Features And Benefits..................................................................... B14-2.-IP... B14-4.-HD... B14-6 ISAF-HYD...................................................................

More information

Plastic bearings that revolve around your needs.

Plastic bearings that revolve around your needs. NON-CORROSIVE n NON-MAGNETIC n LIGHTWEIGHT Plastic bearings that revolve around your needs. FROM MAGNUS MOBILITY SYSTEMS ISO 9001-2008 Certified Plastic bearings that revolve around your needs We go to

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION General Nomenclature Spherical Roller Bearings The spherical roller bearing is a combination radial and thrust bearing designed for taking misalignment under load When loads are heavy, alignment of housings

More information

ERX-TREME Cylindrical OD PN Gold Bearings. High Phosphorus Nickel Plated Outer Race with Tapered Land Race Profile. Land Riding Brass Retainer

ERX-TREME Cylindrical OD PN Gold Bearings. High Phosphorus Nickel Plated Outer Race with Tapered Land Race Profile. Land Riding Brass Retainer Sealmaster PN Gold Style Ball Bearings Sealmaster PN Gold bearings feature high phosphorus, electroless nickel coated steel with patented seal technology and tapered land outer race profile available in

More information

TIMKEN DEEP GROOVE BALL BEARINGS

TIMKEN DEEP GROOVE BALL BEARINGS TIMKEN DEEP GROOVE BALL BEARINGS DEEP GROOVE BALL BEARING CATALOG INDEX DEEP GROOVE BALL BEARINGS Deep Groove Ball Bearing Range...1 Bearing Size Range...1 Standard 6000 Series...2 Thin-Section 61000 Series...6

More information

Track Rollers/ Cam Followers

Track Rollers/ Cam Followers Track Rollers/ Cam Followers Page Nomenclature...................................... 460 Introduction....................................... 462 Identification....................................... 462

More information

CYLINDRICAL ROLLER BEARING CATALOG TIMKEN THRUST AND PLAIN BEARINGS CATALOG

CYLINDRICAL ROLLER BEARING CATALOG TIMKEN THRUST AND PLAIN BEARINGS CATALOG CYLINDRICL ROLLER BERING CTLOG TIMKEN THRUST ND PLIN BERINGS CTLOG Spherical Plain Bearings SPHERICL PLIN Overview: Timken s spherical plain bearings consist of a spherically ground inner ring housed in

More information

THE REX DESIGN REPLACEABLE BEARING

THE REX DESIGN REPLACEABLE BEARING Bearings Rexnord Roller Bearings (English-Inch) THE REX DESIGN EASY BEARING CLEARANCE ADJUSTMENT Can be field adjusted to meet application needs. REPLACEABLE BEARING Available in Normal Duty, Medium Duty,

More information

SPLIT MOUNTED HT750/H1000/NT600 INSTALLATION MANUAL

SPLIT MOUNTED HT750/H1000/NT600 INSTALLATION MANUAL 9/26/16 HIGH TEMP BEARINGS SPLIT MOUNTED HT750/H1000/NT600 INSTALLATION MANUAL www.hightempbearings.com HTB Split Mounted HT750/1000/NT600 Sleeve Bearings Installation HTB Manual REV A REV A Split Mounted

More information

TOUGH AND LONG LIFE (TL) SERIES SPHERICAL ROLLER BEARINGS

TOUGH AND LONG LIFE (TL) SERIES SPHERICAL ROLLER BEARINGS TOUGH AND LONG LIFE (TL) SERIES SPHERICAL ROLLER BEARINGS TOUGH PERFORMANCE IN HIGH TEMPERATURES. High temperature processing and manufacturing environments, such as those in the dryer section of paper

More information

FKL Bearings in Vibrating Screens

FKL Bearings in Vibrating Screens FKL Bearings in Vibrating Screens Bearings in Vibrating Screens: Vibrating screens are used for grading (i.e. separation of solid materials by grain size) of materials and other vibratory machinery such

More information

Linear Bushings and Shafts Inch Series

Linear Bushings and Shafts Inch Series Industrial Hydraulics Electric Drives and Controls Linear Motion and Assembly Technologies Pneumatics Service Automation Mobile Hydraulics Linear Bushings and s Inch Series The Drive and Control Company

More information

Axial-radial cylindrical roller bearings

Axial-radial cylindrical roller bearings Axial-radial cylindrical roller bearings Designs and variants.............. 320 Bearing data..................... 321 (Boundary dimensions, tolerances) Product table 5.1 Axial-radial cylindrical roller

More information

BROWNING TAPERED ROLLER BEARINGS 900/E920 SERIES. Tapered Roller Bearings PB900 PBE920 FEATURES/BENEFITS

BROWNING TAPERED ROLLER BEARINGS 900/E920 SERIES. Tapered Roller Bearings PB900 PBE920 FEATURES/BENEFITS Dimensionally Interchangable with most Type E s Allow for Combination Radial and Thrust Loads Eccentric Lock Collar PB900 Centrap Labyrinth Seal One Piece Ductile Iron Housing Elongated Bolt Holes to Facilitate

More information

DODGE USAF 200/300 Direct Mount Pillow Block Bearings

DODGE USAF 200/300 Direct Mount Pillow Block Bearings DODGE USAF 200/300 Direct Mount Pillow Block Bearings These instructions must be read thoroughly before installation or operation. This instruction manual was accurate at the time of printing. Please see

More information

What is BF? Tubes Sprockets Grooves Coatings & Platings Axles Axle Machining Bearings Roller Assembly Tapers Formed Tubes Special Features

What is BF? Tubes Sprockets Grooves Coatings & Platings Axles Axle Machining Bearings Roller Assembly Tapers Formed Tubes Special Features ROLLERmANUAL Table of Contents What is BF? Tubes Sprockets Grooves Coatings & Platings Axles Axle Machining Bearings Roller Assembly Tapers Formed Tubes Special Features Applications Questions to Ask 2

More information

Drawn cup needle roller bearings

Drawn cup needle roller bearings Drawn cup needle roller bearings Sealed drawn cup needle roller bearings... 78 Full complement drawn cup needle roller bearings... 79 3 Dimensions... 79 Tolerances... 79 Misalignment... 80 Cages... 80

More information

E1 Spherical Roller Bearings. The new standard for performance and operational reliability

E1 Spherical Roller Bearings. The new standard for performance and operational reliability E1 Spherical Roller Bearings The new standard for performance and operational reliability FAG s innovative E1 spherical roller bearing provides increased reliability, greater economic efficiency, and superior

More information

NTN Ball Screw Support Bearings

NTN Ball Screw Support Bearings Ball Screw Support Bearings 1. Ball Screw Support Bearings CONTENTS 1. Ball Screw Support Bearings q Angular contact thrust ball bearing A-BST w Duplex angular contact ball bearing HT 1 e Needle roller

More information

SKF insert bearing units UC range

SKF insert bearing units UC range SKF insert bearing units range SKF range, designed for JIS* equipment You need a robust and reliable insert bearing unit solution, one that s easy to install, simple to order and improves productivity.

More information

Spherical Roller Bearings Units: Rexnord PT Select Series

Spherical Roller Bearings Units: Rexnord PT Select Series Excerpt from Rexnord Bearings Catalog #BR101-100EN Spherical Roller Bearings Units: Rexnord PT Select Series Contents Page Features and Benefits 192 Nomenclature 193 Engineering 194 Dimensions Pillow Blocks

More information

NSK Standard Ball Screws High Speed SS Series

NSK Standard Ball Screws High Speed SS Series NSK Standard Ball Screws igh Speed SS Series NSK s high speed and low noise ball screws provide high-level performance for drive systems of industrial machines such as those used in manufacturing. standard

More information

Why bigger isn t always better: the case for thin section bearings

Why bigger isn t always better: the case for thin section bearings White Paper Why bigger isn t always better: the case for thin section bearings Richard Burgess, Les Miller and David VanLangevelde, Kaydon Bearings Typical applications Thin section bearings have proven

More information

Double-row ball bearings

Double-row ball bearings Double-row ball bearings Radial double-row ball bearings 262 Definition and capabilities 262 Series 262 Tolerances and clearances 262 Design criteria 263 Suffixes 263 Characteristics 264 Radial double-row

More information

Slide-Rite & Slide-Rite CR Gearbox

Slide-Rite & Slide-Rite CR Gearbox Gearboxes Gearbox and CR Gearbox Pages 2 through 7 Float-A-Shaft (FAS) Gearbox Pages 8 through 24 Visit www.tolomatic.com for the latest updates, CAD files and ordering. GEARBOXES www.tolomatic.com 1 GEARBOXES

More information

*複合型/B _*複合型/B /05/25 10:10 ページ 151 Complex Bearings

*複合型/B _*複合型/B /05/25 10:10 ページ 151 Complex Bearings Complex Bearings Complex bearings Complex Bearings complex bearing is comprised of a needle roller bearing of supporting radial load and a thrust bearing for supporting axial load which are assembled integrally.

More information

Guide units. For toolmaking, fixture manufacturing and machine engineering

Guide units. For toolmaking, fixture manufacturing and machine engineering Guide units For toolmaking, fixture manufacturing and machine engineering Guide units in compliance with DIN, ISO and STEINEL standards or according to your specifications Guide pillars Guide and pillar

More information

CONTENTS. IMPERIAL - IP, ISAF and ISN

CONTENTS. IMPERIAL - IP, ISAF and ISN CONTENTS IMPERIAL - IP, ISAF and ISN Features / Benefi ts IMPERIAL.......................................................... B10-3 IMPERIAL-E........................................................ B10-8

More information

Recommended Torque Setscrews D-LOK Mounting Bolts Recommended Torque Standard Ball Bearing Insert. EZ-KLEEN Recom. Torque. Recom.

Recommended Torque Setscrews D-LOK Mounting Bolts Recommended Torque Standard Ball Bearing Insert. EZ-KLEEN Recom. Torque. Recom. Bearing Reference ULTRA KLEEN E-Z KLEEN Extreme Duty Setscrew Ball Bearing GRIP TIGHT D-LOK Ball Bearing SELECTION Setscrew Ball Bearings Setscrew Key Hex Across Flats Recommended Setscrews D-LOK Mounting

More information

Vibrating Mechanism Bearings

Vibrating Mechanism Bearings Vibrating Mechanism Bearings Vibrating equipment represents some of the most demanding applications for anti-friction roller bearings. This type of equipment includes screens, vibrating finishing mills,

More information

Bearing retention and clearances

Bearing retention and clearances Bearing retention and clearances Bearing retention 9 Radial retention 9 Axial retention 91 Positioning of single bearing assemblies 91 Positioning of two bearing assemblies 92 Axial retention processes

More information

Dodge ISN mounted spherical roller bearings

Dodge ISN mounted spherical roller bearings Engineered for reliability and long life Easy to install and remove Factory sealed and greased Patented sealing system for extended life Patented integral adapter mounting and dismounting system No shaft

More information

POSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS. HeliFlow Industrial Series

POSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS. HeliFlow Industrial Series POSITIVE DISPLACEMENT LOWERS & VACUUM PUMPS HeliFlow Industrial Series It's all about... the HeliFlow The HeliFlow Series integrates proven experience with blower design and manufacturing techniques to

More information

HOW TO ORDER SPECIAL FINISHES

HOW TO ORDER SPECIAL FINISHES HOW TO ORDER There are two ways to specify DODGE Bearings. Most of the product offerings have part numbers with listings shown throughout this catalog. Use of part numbers ensures accurate order processing.

More information

CONTENTS. IMPERIALt. Impact Spanner Wrench. IMPERIAL Lockplate Kit... B Features / Benefits. IP Pillow Blocks Bolt

CONTENTS. IMPERIALt. Impact Spanner Wrench. IMPERIAL Lockplate Kit... B Features / Benefits. IP Pillow Blocks Bolt CONTENTS IMPERIALt Features / Benefits... B8--2 Nomenclature... B8--3 Selection... B8--6 Selection/Dimensions... B8--14 IP Pillow Blocks -- 2--Bolt IP Pillow Blocks -- 4--Bolt...... B8--14 B8--16 ISAF

More information

THE ORIGINAL SPLIT ROLLER BEARING. Visit CooperBearings.com

THE ORIGINAL SPLIT ROLLER BEARING. Visit CooperBearings.com OVERVIE W THE ORIGINAL SPLIT ROLLER BEARING Visit CooperBearings.com THE COMPANY Since inventing the split roller bearing in 1907, Cooper has become synonymous with the manufacture of quality, long-lasting

More information

BEARINGS FOR RAILWAY APPLICATIONS

BEARINGS FOR RAILWAY APPLICATIONS BEARINGS FOR RAILWAY APPLICATIONS BEARINGS FOR RAILWAY APPLICATIONS The railway industry is a promising field world-wide. ZKL therefore dedicates special attention to the bearings for rail vehicles. The

More information

Urethane. Ralphs-Pugh Urethane Products

Urethane. Ralphs-Pugh Urethane Products Ralphs-Pugh Products elastomers are unique because they combine many of the advantages of rigid plastics, metals and ceramics with the elasticity of rubber. resists abrasion and reduces the affects of

More information

Linear Bushing General Catalog

Linear Bushing General Catalog General Catalog A Technical Descriptions of the Products B Product Specifications (Separate) Features and Types... Features of the... Structure and features... Dedicated Shafts for Model LM... Standard

More information

High-Speed Precision Bearings

High-Speed Precision Bearings igh-peed Precision Bearings ROBUT eries ROBUT eries was developed using NK s material, evaluation, and analysis technologies to improve the performance of machine tools. Building on the new technologies

More information

THE ORIGINAL. SPLIT ROLLER BEARING Visit CooperBearings.com

THE ORIGINAL. SPLIT ROLLER BEARING Visit CooperBearings.com OVERVIE W THE ORIGINAL SPLIT ROLLER BEARING Visit CooperBearings.com THE COMPANY Since inventing the split roller bearing in 1907, Cooper has become synonymous with the manufacture of quality, long-lasting

More information

Instruction Manual for HSPA Take-Up Units

Instruction Manual for HSPA Take-Up Units Installation Instruction Manual for HSPA Take-Up Units Warning: To ensure the drive is not unexpectedly started, turn off and lockout the power source before proceeding. Failure to observe these precautions

More information

Cylindrical roller bearings

Cylindrical roller bearings Cylindrical roller bearings Cylindrical roller bearings are manufactured in a various range of constructive types and sizes, particularly single row cylindrical roller bearings but also two or more row

More information

Tapered Roller Bearings in X-life Design

Tapered Roller Bearings in X-life Design Tapered Roller Bearings in X-life Design Contents Design and safety guidelines Page Features X-life... 2 Operating temperature... 4 Cages... 4 Suffixes... 4 Compensation of angular misalignments... 4

More information

DryLin R Linear Plain Bearings, Fast and Quiet

DryLin R Linear Plain Bearings, Fast and Quiet +90º 40º +250º 100º Linear Plain Bearings, Fast and Quiet linear plain bearings, made from solid polymers, are dimensionally equivalent to standard ball bearings. They are made entirely of wear resistant

More information

Product Brochure. Dodge ISN bearings

Product Brochure. Dodge ISN bearings Product Brochure Dodge ISN bearings We provide motors, generators and mechanical power transmission products, services and expertise to save energy and improve customers, processes over the total lifecycle

More information

THE REX DESIGN. RUGGED HOUSING Standard material cast iron. Steel or ductile iron available on request.

THE REX DESIGN. RUGGED HOUSING Standard material cast iron. Steel or ductile iron available on request. THE REX DESIGN EASY BEARING CLEARANCE ADJUSTMENT can be field adjusted to meet application needs. REPLACEABLE BEARING Available in Normal Duty, Medium Duty, Heavy Duty and Adapter Sleeve mounting to suit

More information

Integral tapered roller bearings Series JK0S

Integral tapered roller bearings Series JK0S Integral tapered roller bearings Series JK0S Technical Product Information Features Features FAG integral tapered roller bearings JK0S are ready-to-fit, easily mounted units. The single row bearings are

More information

DODGE USAF 500 SERIES Pillow Blocks

DODGE USAF 500 SERIES Pillow Blocks INSTRUCTION MANUAL for ADAPTER MOUNTED DODGE USAF 500 SERIES Pillow Blocks WARNING: Because of the possible danger to person(s) or property from accidents which may result from the improper use of products,

More information

E920 Series Bearings. Locking Collars. Tapered Roller Bearing. Locking Collars. Rubber Contact Seal. Outer Race. One-Piece Cast Iron Housing

E920 Series Bearings. Locking Collars. Tapered Roller Bearing. Locking Collars. Rubber Contact Seal. Outer Race. One-Piece Cast Iron Housing rowning E920 Series Tapered Roller earing rowning 920 series mounted tapered roller bearings feature one-piece durable cast iron non-expansion housings with Type E mounting dimensions and limited misalignment.

More information

Crossed Roller Ways. Description of each series and Table of dimensions. Anti-Creep Cage Crossed Roller Way

Crossed Roller Ways. Description of each series and Table of dimensions. Anti-Creep Cage Crossed Roller Way Crossed Roller Ways Description of each series and Table of dimensions Crossed Roller Way Page - to -7 Anti-Creep Cage Crossed Roller Way Page - to - Crossed Roller Way Unit Page - to - In the table of

More information

SPLIT CYLINDRICAL ROLLER BEARINGS

SPLIT CYLINDRICAL ROLLER BEARINGS SPLIT CYLINDRICAL ROLLER BEARINGS PERFORMANCE SOLUTIONS RANGE OF HOUSINGS Engineered to perform Standard support with complete housing and bearing Flange support Take up tension unit complete with housing

More information

A Zy-Tech Global Industries Product

A Zy-Tech Global Industries Product A Zy-Tech Global Industries Product Worm & evel Gear Operators Another quality product from Zy-Tech Global Industries, Inc. Zy-Gear gear operators are designed for long lasting dependable service in oil

More information

F A / Co e. Shaft Tolerances Normal Shaft Size Commercial Recommended Shaft Tolerances Inches Shaft Tolerances Eccentric Lock Ball Bearings

F A / Co e. Shaft Tolerances Normal Shaft Size Commercial Recommended Shaft Tolerances Inches Shaft Tolerances Eccentric Lock Ball Bearings s Ball Take-Up Frames Engineering Part Number Index Keyword Index s DODGE mounted ball bearings are primarily designed for radial loading. However, they have the capacity to carry thrust loads and combined

More information

Inner block. Grease nipple. Fig.1 Structure of LM Guide Actuator Model KR

Inner block. Grease nipple. Fig.1 Structure of LM Guide Actuator Model KR LM Guide ctuator Model LM Guide + all Screw = Integral-structure ctuator Stopper Housing all screw Inner block Grease nipple Outer rail earing (supported side) Housing Stopper Double-row ball circuit earing

More information

Flanged housings FNL series

Flanged housings FNL series Flanged housings FNL series Bearing types Self-aligning ball bearings Spherical roller bearings CARB toroidal roller bearings Bearing dimension series 02, 22 FNL flanged housings are well-proven machine

More information

4 Self aligning ball bearings

4 Self aligning ball bearings Rolling bearings 4 Self aligning ball bearings Designs and variants... 538 Basic design bearings... 539 Bearings with an extended inner ring.. 540 Cages... 540 Sealing solutions... 540 Greases for sealed

More information

DryLin R Linear Plain Bearings, Fast and Quiet

DryLin R Linear Plain Bearings, Fast and Quiet +90º 40º +250º 100º Linear Plain Bearings, Fast and Quiet linear plain bearings, made from solid polymers, are dimensionally equivalent to standard ball bearings. They are made entirely of wear resistant

More information