1 HEATING COMPONENTS COMBINATION SINGLE STAGE DUAL GAS VALVE, REDUNDANT REPLACES MANY POPULAR BRANDS P465 SLOW OPENING SINGLE STAGE LP KIT INCLUDED QUICK CONNECT TERMINALS INLET AND OUTLET PRESSURE TAPS OFF-PILOT-ON PROGRAMMED LIGHTING SEQUENCE FOR STANDING PILOT APPLICATION PILOT COMPRESSION FITTING FOR 1/4 INCH O.D. TUBING FOR USE WITH GAS TYPE CAPACITY PRESS. SIZE NAT. L.P BTU s IN. W.C. 1/2 x 3/4 YES YES* P * *LP kit is included. REPLACES: Single and Dual valve standing pilot controls with rated capacity on natural gas at 130,000 BTU/HR. HONEYWELL: V800 & VR800 WHITE-RODGERS: 36C03-300, 36C03-330, 36C & 36C ITT GENERAL: B57RA68, B57RF68, B57RH161, B59R02 & B59R06 ROBERTSHAW: , & STEVECO:
2 COMBINATION GAS CONTROLS HEATING COMPONENTS P467 MANUAL MAIN AND PILOT GAS SHUTOFF PILOT GAS OUTLET WITH ADJUSTMENT OUTLET GAS PRESSURE TAP AUTO PILOT SHUTOFF AND PRESSURE REGULATION AS NOTED CAPACITY: 240,000 BTU s PRESSURE SET AT: 125M SIZE PRESS USE WITH 100% REG. NAT. L.P. SHUTOFF 1/2 x 3/4 YES YES - NO EF53CK185 1/2 x 3/4 YES YES YES YES EF680006* 1/2 x 1/2 YES YES - NO EF53CK198 1/2 x 1/2 NO - YES YES EF53CK208 1/2 x 1/2 YES YES - YES EF53CK205 P468 SIZE PRESS REG. USE WITH NAT. L.P. MANUAL MAIN AND PILOT GAS SHUTOFF PILOT GAS OUTLET WITH ADJUSTMENT OUTLET GAS PRESSURE TAP AUTO PILOT SHUTOFF AND PRESSURE REGULATION AS NOTED PRESSURE SET AT: 3.5 C& 150M EF33CB M EF53CK248 CAPACITY 1000 BTU s 100% SHUT- OFF 1/2 x 1/2 YES YES NO EF33CB181 3/4 x 3/4 YES - YES 486 YES EF53CK248 *Kit contains EF53CK188 VALVE, Blankoff plate for converting to LP gas applications and 3/4 to 1/2 reducer bushing. Slow Opening P469 MANUAL MAIN AND PILOT GAS SHUTOFF NATURAL GAS PILOT OUTLET WITH ADJUSTMENT OUTLET GAS PRESSURE TAP HEAT MOTOR GIVES TIME DELAY SIZE 1/2 x 3/4, HAS PRESSURE REGULATOR, USE WITH NATURAL GAS, PRESSURE SET AT. CAPACITY: 164,000 BTU s NON 100% SHUTOFF INCLUDES 3/4 x 1/2 REDUCER BUSHING : EF53CK198 COMBINATION DUAL VALVE GAS CONTROLS P470 DUAL MAIN ELECTRIC VALVES - REDUNDANT MANUAL MAIN GAS SHUTOFF OUTLET GAS PRESSURE TAP (EF32CW183) INLET & OUTLET GAS PRESSURE TAPS (EF32CW190) PILOT GAS ADJUSTMENT. I.I.D. SYSTEM APPLICABLE PICK AND HOLD OPERATION. SIZE USE w/ CAPACITY PRESS. (TYPE GAS) 1000 BTU s SET AT 1/2 x 3/4 NAT M EF32CWI83* 1/2 x 3/4 NAT EF32CWI90 333
3 HEATING COMPONENTS COMBINATION DUAL VALVE GAS CONTROLS P471 SINGLE STAGE - REDUNDANT SLOW OPENING PILOT GAS ADJUSTMENT SIZE USE WITH CAPACITY PRESS. IN. W.C. NAT. L.P BTU s 1/2 x 3/4 YES EF32CB212 P474 SINGLE STAGE - REDUNDANT USE WITH G67 ELECTRONIC IGNITION SIZE USE WITH CAPACITY PRESS. NAT. L. P BTU s IN. W.C. 1/2 x 3/4 YES EF33CZ213 P472 DUAL MAIN ELECTRIC VALVES - REDUNDANT I.I.D. SYSTEM APPLICABLE OUTLET GAS PRESSURE TAP SOLENOID COILS EASILY REPLACED NATURAL GAS SIZE 1/2 x 3/4 PRESSURE SET AT: 125M CAPACITY 200,000 BTU s : EF33CZ206 SIMILAR MODELS TO RCD EF33CZ206 WITH SLIGHT CHANGES: SIZE 1/2 x 1/2 CAPACITY 179,000 BTU s : EF33CZ209 SOLENOID COILS COVERED IGNITER MOUNTS NEXT TO COILS : EF33CZ210 P473 DUAL MAIN ELECTRIC VALVES - REDUNDANT MANUAL MAIN GAS SHUTOFF ADJUSTABLE PILOT GAS FLOW OUTLET GAS PRESSURE TAP NATURAL GAS I.I.D. SYSTEM APPLICABLE P475 DUAL MAIN ELECTRIC VALVES - REDUNDANT MANUAL MAIN GAS SHUTOFF I.I.D. SYSTEM APPLICABLE PILOT GAS ADJUSTMENT OUTLET GAS PRESSURE TAP NATURAL GAS SIZE CAPACITY PRESS BTU s SET AT 1/2 x 3/ EF NOTE: Package includes EF32CB210 valve and 3/4 to 1/2 reducer bushing. SIZE CAPACITY PRESS BTU s SET AT SYSTEM 1/2 x 1/ M I.I.D. EF32CB195 3/4 x 3/ M I.I.D. EF34CW245 *Special pilot porting for zip tube ignition.. 334
4 HEATING COMPONENTS COMBINATION TWO STAGE GAS CONTROLS P476 PRE-SELECTED FIRST STAGE FIRING RATE ADJUSTABLE HIGH FIRE RATE MANUAL MAIN GAS SHUTOFF PILOT GAS ADJUSTMENT OUTLET GAS PRESSURE TAP USE CAPACITY PRESS. 100% SIZE WITH 1000 IN. W.C. SHUT- NAT. L.P. BTU s LO HI OFF 1/2 x 1/2 - YES NO EF33CW186 3/4 x 3/4 YES NO EF /4 x 3/4 YES YES EF34CW245 P478 DUAL MAIN ELECTRIC VALVES - REDUNDANT PRE-SELECTED FIRST STAGE FIRING RATE MANUAL MAIN GAS SHUTOFF PILOT GAS ADJUSTMENT OUTLET GAS PRESSURE TAP I.I.D. SYSTEM APPLICABLE PRESS. SIZE USE WITH CAPACITY IN. W.C BTU s NAT. L.P. LO Hi 3/4 x 3/4 YES EF33CB265 1/2 x 1/2 - YES EF33CB209 3/4 x 3/4 YES EF33CB265 3/4 x 3/4 - YES EF33CB268 P477 INTERNAL PRESSURE SWITCH DUAL MAIN ELECTRIC VALVES - REDUNDANT PRE-SELECTED FIRST STAGE FIRING RATE MANUAL MAIN GAS SHUTOFF PILOT GAS ADJUSTMENT OUTLET GAS PRESSURE TAP I.I.D. SYSTEM APPLICABLE PRESS. SIZE USE WITH CAPACITY IN. W.C BTU s NAT. L.P. LO HI 3/4 x 3/4 - YES EF33CW289 P479 DUAL MAIN ELECTRIC VALVES - REDUNDANT PRE-SELECTED FIRST STAGE FIRING RATE MANUAL MAIN GAS SHUTOFF OUTLET GAS PRESSURE TAP I.I.D. SYSTEM APPLICABLE PRESS. SIZE USE WITH CAPACITY IN. W.C BTU s NAT. L.P. LO Hi 1/2 x 3/4 YES EF33CZ255 1/2 x 3/4 - YES EF33CZ256 P471 P681-VR8345M Universal Electronic Ignition Gas Valve CONTROL INCLUDES MANUAL VALVE, TWO AUTOMATIC OPERA- TORS, PRESSURE REGULATORS, PILOT ADJUSTMENT, PILOT PLUG AND IGNITION ADAPTER. HIGHEST CAPACITY (415,000 BTU MAX. REG., NG) OF ANY ELEC- TRONIC IGNITION VALVE IN THE INDUSTRY. REPLACES VIRTUALLY ANY IP, HIS, OR DSI GAS CONTROL. FOR USE WITH NATURAL OR MANU- FACTURED GAS OR LP GAS. HONEYWELL : VR8345M4302. P660-VR83A Continuous Pilot Dual Automatic Valve Combination Gas Controls CONTROLS INCLUDE SAFETY SHUTOFF, MANUAL VALVE, TWO AUTOMATIC OPERA- TORS, PRESSURE REGULATOR AND PILOT ADJUSTMENT. REPLACES OVER 95 PERCENT OF THE STANDING PILOT GAS VALVES; MAXIMUM CAPACITY RATING IS 150% OF THE COM- PETITIVE VALVES. MEETS 1979 ANSI STANDARDS FOR REDUNDANCY IN GAS VALVE OPERATION. PART NUMBER P660-VR83A3500 P660-VR83A3518 P660-VR83A4508 P660-VR83A4516 HONEYWELL PART NUMBER VR8300A3500 VR8300A3518 VR8300A4508 VR8300A
5 BURNER IGNITION SYSTEMS P4318 HEATING COMPONENTS P660-Y8610U Universal Retrofit Intermittent Pilot Gas Burner Ignition System COMBINES THE MOST UNIVERSAL IGNITION CONTROLS (S8610 IP MODULE & VR8304M GAS VALVE) INTO THE MOST CAPABLE RETROFIT KIT AVAILABLE. SINGLE-ROD OR DUAL-ROD IGNITION AND SENSING SIMPLIFIES INSTALLATION WITH ONLY ONE LEAD TO WIRE. SOPHISTICATED LOCKOUT TIMING ELIMINATES NUISANCE LOCKOUTS. HONEYWELL : Y8610U3003. P660-Y8610F Retrofit Intermittent Pilot Gas Burner Ignition System Y8610F KITS ARE FOR USE WITH NATURAL GAS ONLY: CONTINUE TRIAL FOR IGNITION UNTIL THE PILOT LIGHTS OR THE SYSTEM IS SHUT DOWN MANUALLY. COMPLETE KIT FOR CONVERTING STANDING PILOT TO INTERMITTENT PILOT. NOT 100% SHUTOFF ON PILOT FLAME LOSS; IDEAL FOR MOST NATURAL GAS SYSTEMS. HONEYWELL : Y8610F5003. SMARTVALVE SYSTEM P682-SV9501M SmartValve System COMBINES GAS FLOW AND ELECTRONIC INTERMITTENT PILOT SEQUENCING FUNCTIONS INTO A SINGLE UNIT. SUITABLE FOR A WIDE RANGE OF GAS-FIRED APPLIANCES INCLUDING RESIDEN- TIAL FURNACES, ROOFTOP FURNACES, RESIDENTIAL BOILERS, UNIT HEATERS, INFRARED HEATERS, AND SPACE HEATERS. HONEYWELL : SV9501M2528. P
6 SINGLE FUNCTION GAS CONTROLS HEATING COMPONENTS P480 FAST ACTING SOLENOID NATURAL AND L.P. GASES HIGH CAPACITY 1/4 IN. ELECTRICAL QUICK CONNECTS P486 MAIN LINE GAS VALVE SERVICE FAST ACTING SOLENOID NATURAL AND L.P. GASES HIGH CAPACITY 30 ELECTRICAL LEADS (EXCEPT EF11CW182) PILOT SWITCH RECEPTACLE, EXCEPT-. RCD : EF11CW182 PILOT VALVES SIZE BTU s COIL PER HOUR VOLTS 1/2 x 1/2 329, EF11CW042* 1/2 x 1/2 329, EF11CW044 *Contains (2) 1/2 x 1/4, (2) 1/4 x 1/8 and (2) 1/2 x 3/8 reducer bushings. Contains (2) 1/2 x 1/4 and (2) 1/4 x 1/8 reducer bushings. SIZE BTU s PER HOUR COIL VOLTS 1/2 x 1/2 340, EF11CW042* 1/2 x 1/2 340, EF11WH025 1/2 x 1/2 329, EF11CW032 3/4 x 3/4 500, EF11WK025 3/4 x 3/4 500, EF11WK115 *Contains (2) 1/2 x 1/4, (2) 1/4 x 1/8 and (2) 1/2 x 3/8 reducer bushings. Contains (2) 1/2 x 1/4 and (2) 1/4 x 1/8 reducer bushings. MANUAL GAS SHUTOFF VALVE P482 FIG. A P483 FIG. B ALUMINUM BODY 1/8 NPT PILOT CONNECTION PILOT SHUTOFF VALVE CONNECTIONS: 1/8 NPT x 1/4 COMPRESSION COUPLING FIG. SIZE (NPT) PILOT CONN. OVERALL LENGTH HEIGHT A 1/2 x 1/2 Both Plugged EV44CK047 B 3/4 x 3/4 One Plugged EV44CK052 P487 TYPE BODY Right Angle Aluminum EV43CR
7 GAS VALVE ACCESSORIES GAS PRESSURE REGULATOR HEATING COMPONENTS REGULATOR IS 5 PSI TO 4 INCHES WC. P488 VENDOR PIPE SIZE (IN.) INPUT CAPACITY NATURAL GAS (BTUH) NOTE: Pressure set at 3 inches wc.; however, serviceman should always check calibration at time of installation. GAS VALVE CONVERTERS/KITS Maxitrol 1/2 RV52 1/2 262,000 EF Maxitrol 3/4 RV53 3/4 687,750 EF P489 REGULATOR AND GASKET SET USED TO CONVERT ROBERT- SHAW VH700 & 700 MODEL GAS VALVES FROM REGULATED NATURAL GAS TO REGULATED L.P. GAS MFG. : : CONVERTS JOHNSON CONTROL GAS VALVES FROM NATURAL GAS TO REGULATED L.P. GAS MODELS WITH TOP ADJUSTED REGULATORS: G60 - MFG : Y71GF : EF39AB009 G : EF39AB010 MODELS WITH BOTTOM ADJUSTED REGULATORS: G96 & G : EF39AB011 HONEYWELL VALVES WITH V5306, VR8200 OR VR8204 PRESSURE REGULATORS CAN BE CONVERTED FOR REG- ULATED L.P. GAS SERVICE BY USING THESE KITS. COM- PLETE REGULATOR NEED NOT BE CHANGED. V MFG.: : VR8200, VR MGF. : : P490 EF39AB001 EF39ZW025 P493 BUSHING P492 SPRING COLOR SIZE RED 3.3 x.30 CONVERTS NOM. 3.5 NAT. TO NOM. 11.0" L.P. PLAIN 3.0 x.30 CONVERTS NOM LP. TO NOM. 3.5" NAT. HONEYWELL STEP OPENING REGULATOR FOR CONVER- SION OF RCD EF33CY254 VALVE FROM NATURAL GAS SERVICE TO REGULATED L.P. GAS (11.0- W.C./4.5- W.C.) MFG. : V5307A117 : 58GP REGULATOR SPRING CON- VERTS W-R MODEL 36C & 36E GAS VALVE FROM NATURAL GAS TO REGULATED L.P. GAS MFG. : : EF39ZWO23 RCD 646 & 647 VALVE CON- VERSIONS /2 x 3/4 NPT FACE BUSHING USE TO ADAPT 3/4 NPT PORTED GAS VALVES FOR USE WHERE 1/2 NPT PIPING AND MANIFOLDS ARE PROVIDED P494 : CA57AP
8 ORIFICES MAIN BURNER ORIFICES P495 DRILL SIZE DRILL SIZE 3/8 ACROSS FLATS, 11/32 x 32 NST,.31 LONG 38 (.101) LH32DB (.089) LH32DB (.093) LH32DB (.059) LH32DB (.055) LH32DB054 7/16 ACROSS FLATS, 1/8 x 27 NPT,.50 LONG 53 (.059) LH32DB (0.55) LH32DB (.067) LH32DB (.057) LH32DB (.098) LH32DB (.082) LH32DB (.086) LH32DB (.046) LH32DB (.052) LH32DB (.093) LH32DB (.089) LH32DB (.081) LH32DB208 9/16 ACROSS FLATS, 1/4 x 18 NPT, 5/8 LONG 54 (.055) LH32JB (.096) LH32JB (.059) LH32JB (.101) LH32JB (.063) LH32JB (.106) LH32JB (.093) LH32JB093 P496 DRILL SIZE F DRILL SIZE 7/16 ACROSS FLATS, 1/8 x 27 NPT, 7/8 LONG, DIA (0.52) LH32EB (.082) LH32EB081 P500 DRILL SIZE RCD DRILL SIZE 9/16 ACROSS FLATS, 1/4 x 18 NPT, 7/8 LONG 52 (.063) LH32RQBG31 35 (.110) LH32RQ110 7/16 ACROSS FLATS, 1/8 27 NPT, 7/8 LONG 56 (.046) LH32JB (.052) LH32JB (.089) LH32JB (.055) LH32JB (.096) LH32JB (.059) 68459C53 40 (.098) LH32JB (.078) LH32JB (.104) LH32JB104 P501 DRILL SIZE I DRILL SIZE 9/16 ACROSS FLATS, 1/4 x 18 NPT, 7/8 LONG, 495 DIA. 65 (.035) LH32RF (.082) LH32RF (.046) LH32RF (.086) LH32RF (.052) LH32RF (.096) LH32RF (.055) LH32RF (.101) LH32RF (.070) LH32RF (.113) LH32RF (.073) LH32RF (.116) LH32RF116 PILOT ORIFICES WHITE-RODGERS HONEYWELL GENERAL CONTROLS P497 P498 P499 BDP ORIFICE PART TYPE SIZE MARKING GAS WHITE-RODGERS USED WITH E SERIES PILOTS U LP LH39WD U LP LH39WD U NAT LH39WD OU NAT LH39WD020 BDP USED WITH 732, 733, 734 and 740 PILOTS.017 BRIGHT NAT LH39JN001 HONEYWELL USED WITH Q308, Q314, Q345 PILOTS.010 BLACK LP LH32RMO BRIGHT NAT LH32RMO BBR12 LP LH32AN BBR14 NAT LH32AN014 P502 P503 ROBERTSHAW PENN P504 ORIFICE PART TYPE SIZE MARKING GAS GENERAL CONTROLS USED WITH 26T PILOTS LP LH32DB001 ROBERTSHAW USED WITH 2CH PILOTS.010 LP10 LP LH32DB002 ORIFICE PART TYPE SIZE MARKING GAS DIM. PENN USED WITH J SERIES PILOTS LP 39/64 LH32RN LP 1-1/32 LH32RN LP 1-9/64 LH39GB NAT 39/64 LH39GB NAT 39/64 LH39GB
9 FAN, LIMIT CONTROLS LIMIT CONTROLS P505 MANUAL RESET FOR LINE OR LOW VOLTAGE CIRCUIT DIFFERENTIAL LIMIT 25 F NON-ADJUSTABLE SETTINGS ELEMENT LENGTH: 3" SWITCH TEMP. SETTING ( F) TYPE OPENS CLOSES SPST HH12AD204 P507 TEMP SETTING: ADJ (HH127ZA008) (HH680400) ADJ (HH12ZA011)(HH680405) DIFFERENTIAL: 30 F SWITCH: SPST ELEMENT LENGTH 3-3/8 HH12ZA008 3 HH /8 HH HH FAN CONTROLS KNURLED SHAFTS FOR ADJUSTMENT OF TEMPERATURE SETTING AND DIFFERENTIAL SLOTTED FOR TWO SCREW MOUNTING SWITCH TYPE: SPST P506 TEMP SETTING: FAN OFF - ADJ. 80 F-120 F FAN DIFFERENTIAL: ADJ. 20 F-50 F ELEMENT LENGTH 7 HH12AB140 3 HH12AB141 P508 QUICK CONNECT TERMINALS 24-VOLT FAN ASSIST HEATER TUBE CONSTRUCTION FOR STRENGTH SLOTTED FOR 2 SCREW MOUNTING SWITCH TYPE: SPST ADJUSTABLE FAN SETTINGS TEMP. SETTING: FAN OFF - ADJ. 80 F F FAN DIFFERENTIAL: 30 F ELEMENT LENGTH: 1-1/4" : HH12HA070 TOTALINE COMBINATION FAN, LIMIT CONTROLS MANUAL FAN SWITCH INDIVIDUAL FAN AND LIMIT SWITCHES HELICAL BI-METAL FOR PRECISE SETTING SPST SWITCH ADJUSTABLE SETTINGS DIFFERENTIAL: LIMIT- 25 F TEMPERATURE SETTING: FAN OFF/ON - ADJ. 90 F-135 F (P ,0002) - ADJ. 90 F-130 F (P ) LIMIT OPENS - ADJ. 100 F-250 F (P ,0002) - ADJ. 100 F-220 F (P ) ELEMENT ELEMENT LENGTH LENGTH 8 P P P P
10 FAN, LIMIT CONTROLS P510 WITH FAN ASSIST HEATER TO PREVENT NUISANCE FAN STARTING INDIVIDUAL SENSING ELEMENTS BI-METAL ACTUATED SWITCH TYPE: SPST TEMP SETTING: FAN OFF - ADJ. 90 F-120 F LIMIT OPENS - SEE CHART BELOW DIFFERENTIAL: FAN - 80 F, EXCEPT HH12KA250 WHICH IS 50 F LIMIT - 30 F ELEMENT LENGTH: 7 (EXCEPT HH12ZW125 WHICH IS 5 ) TEMP. SETTING SETTINGS LIMIT OPENS ( F) ADJUSTABLE 250 FAN HH12KA FAN HH12KD ADJ. FAN, LIMIT HH12KD021* ADJ. FAN, LIMIT HH12KD022** 220 FAN HH12KD FAN HH12KD FAN HH12KD FAN HH12ZW125 *With Shield. **Without Shield. IDEAL FOR PLENUM MOUNTING INDIVIDUAL ELEMENTS AND SWITCHES ELEMENTS MAY BE REPOSITIONED PROVIDED WITH COVER P511 SWITCH TYPE: SPST TEMP SETTING:FAN ON - 70 F-150 F LIMIT OPENS F-250 F DIFFERENTIAL:FAN - 15 F-55 F LIMIT - 20 F SETTINGS ADJUSTABLE: FAN, LIMIT ELEMENT LENGTH (IN.) 9 HH12PZ008 P512 SLOTTED FOR 2 SCREW MOUNTING RIGID TUBE CONSTURCTION 24 VOLT FAN ASSIST HEATER QUICK CONNECT ELECTRICAL TERMINALS SWITCH TYPE: SPST *TEMP SETTING: FAN OFF - ADJ. 80 F-120 F LIMIT OPENS - SEE CHART BELOW DIFFERENTIAL: FAN - 35 F; LIMIT - 40 F TEMP. SETTING SETTINGS LIMIT OPENS ( F) ADJUSTABLE /4 HH COMBINATION FAN, LIMIT CONTROLS INDIVIDUAL FAN AND LIMIT SWITCHES HELICAL BI-METAL FOR PRECISE SETTING SPST SWITCH ADJUSTABLE SETTINGS DIFFERENTIAL: LIMIT -25 TEMPERATURE SETTING: FAN OFF/ON -ADJ. 90 F-135 F (HH12AT005,008) -ADJ. 90 F-130 F (HH12AT015) LIMIT OPENS -ADJ. 100 F-250 F (HH12AT005,008) -ADJ. 100 F-220 F (HH12AT015) TEMPERATURE SETTING: FAN ON - 20 TO 90 SECONDS AFTER FAN ASSIST HEATER ENERGIZED (HH12AT016) FAN OFF - ADJ. 100 F LIMIT OPENS - ADJ. 150 F-250 F P509 ELEMENT ELEMENT LENGTH LENGTH 5 HH12AT HH12AT015 8 HH12AT008 8 HH12AT
11 FAN, LIMIT CONTROLS COMBINATION FAN, LIMIT CONTROLS (cont) P509 P232-L4064B Fan and Limit Control FAST RESPONSE BIMETAL ELEMENT WITH LARGER SURFACE AREA ALLOWS FASTER ROTATION DURING TEMPERATURE CHANGE RESPONSE. FASTER TEMPERATURE CHANGE RECOGNITION FOR SAFER OPERATION. WIDER OPENING STEEL SURROUNDING BIMETAL ELEMENT ALLOWS HOT GAS PENETRATION FOR FASTER TEMPERATURE SENSING AND IMPROVED TEMPERATURE TRACKING. TOTALINE HONEYWELL PART NUMBER PART NUMBER DESCRIPTION P232-L4064B-11 L4064B2210 Fan & Limit 11-1/2 P232-L4064B-8 L4064B2228 Fan & Limit, 8 P232-L4064B-5 L4064B2236 Fan & Limit, 5 SWITCH - COMBINATION FAN AND LIMIT P510 ELEMENT LENGTH SWITCH CLOSES ADJ. FAN RANGE ( F) SWITCH OPENS ADJ. FAN RANGE ( F) SWITCH CLOSES ADJ. FAN RANGE ( F) SWITCH OPENS ADJ. FAN RANGE ( F) FIXED 230 FIXED 30 FIXED HH FIXED 200 FIXED 30 FIXED HH FIXED 240 FIXED 30 FIXED HH FIXED FIXED HH
12 FAN SWITCH - INSERTION TYPE FAN, LIMIT CONTROLS KNURLED SHAFTS FOR ADJUSTMENT OF TEMPERATURE SETTING AND DIFFERENTIAL SLOTTED FOR TWO SCREW MOUNTING. P506 ELEMENT LENGTH SWITCH CLOSES ADJUSTABLE FAN RANGE ( F) SWITCH OPENS ADJUSTABLE FAN RANGE ( F) SWITCH TYPE FIXED SPST L4068E SPST HH FIXED SPST HH SPST HH FIXED SPDT HH FAN LIMIT SWITCH - INSERTION TYPE ELEMENT LENGTH SWITCH CLOSES ADJUSTABLE FAN RANGE ( F) SWITCH OPENS ADJUSTABLE FAN RANGE ( F) SWITCH TYPE FIXED 10 FIXED SPDT HH FIXED 30 FIXED SPDT HH FIXED 30 FIXED SPDT HH FIXED 30 FIXED SPDT HH FIXED 30 FIXED SPDT HH11KT FIXED 40 FIXED SPST HH12ZB FIXED 30 FIXED SPST HH12ZA FIXED 40 FIXED SPST HH12ZA169 P
13 IGNITION SYSTEMS PILOT BURNERS P513 The 2H or 2CH Pilot has SPDT switch action for use with 11 volt glow coil systems. PILOT STYLE GAS ORIFICE SIZE 2H w/coil NAT..021 LH H w/o COIL NAT..021 LH The 734 model pilot burner is for use with a 30 MV thermocouple in standing pilot applications. Snap in or threaded thermocouples may be used. P517 P518 LH33JZ053 is a differential expansion pilot equipped with a 2 lead SPST switch for use with glow coil or spark ignition. PILOT ORIFICE STYLE SIZE 732C.017 LH33JZ053 Differential expansion pilot equipped with a 3 lead SPDT switch for use with glow coil or spark ignition. Molex connector included. PILOT ORIFICE STYLE SIZE 740A.017 LH P514 GAS ORIFICE SIZE NAT..017 LH31JZ022 Model E28 pilot burner is for assembly with LH33WZ506 electrode and HH71PD001 sensor. Spark igniter LH33WZ059 and pilot orifice LH39WD020 must be ordered separately. NATURAL GAS P519 MODEL NO. 2CH This LH31RB015 model pilot burner is used in standing pilot applications. 2 pilot orifices are provided. One for natural gas is installed in the burner. The extra one is for use with L.P. gas. GAS ORIFICE SIZE NAT..016 L.P..010 LH31RB015 P515 P516 PILOT ORIFICE STYLE SIZE E LH31WZ507 The following J style pilot burners are for use with LH33CM600 spark igniter. Burners come with spark electrode and high tension lead and insulating boot attached. Sensor LH33CM018 and spark generator LH33CZ007 required. P520 MODEL NO. Q345 P313A The Q345 pilot burner includes pilot orifice, spark electrode and flame ground. This burner is for use with Honeywell S86 spark module. Converts to LP gas with LH32RM015 pilot orifice. GAS ORIFICE SIZE NAT..018 LH HOOD LEAD ORIFICE POSITION* LENGTH SIZE LH LH31CM017 ST LH31CM023 ST LH , LH660003** LH ST LH31CM300 *Angle of hood as viewed from electrode LH-Left Hand, ST-Straight. ** Includes LH31CM021 Nat. gas burner and LH32RN009 orifice for L.P. conversion. P524 P524B Q314A pilot burner is a nonaerated type with.018 orifice for use with natural gas LH
14 IGNITION SYSTEMS PILOT BURNERS The E25 and E27 model pilot burners are for use with LH31WM001 Igniter and HH71PD001 Sensor. LH33WM001 Igniter must be used with HT01AW024 Ignition Transformer. Q314A pilot burner is a non-aerated type with.018 orifice for use with natural gas. Pilot orifice LH39WD020 not furnished. P524 NATURAL GAS P521 ORIFICE SIZE:.020 MODEL NUMBER E25 (LH) E27 (RH) LH31WF038 LH31WF039 P524B : LH31AC013 P524A : LH31AC015 IGNITERS P522 This solid state igniter features push on high tension lead connector. Igniter provides continuous spark until pilot flame is established. 24 volt system. Replaces: LH33EP030, LH33WZ502. IGNITER MODEL: 990 VOLTS FUNCTION 24 NON-100% LOCKOUT LH33WZ MIN. 100% LOCKOUT LH33WZ MIN. 100% LOCKOUT w/20 SEC. PILOT GAS PREPURGE LH33WZ513 P523 This igniter provides intermittent pilot burner ignition. S86E provides continuous trial for ignition. S86G and S86H provides safe lockout if pilot does not ignite in 90 second trial for ignition period, System volts IGNITER COMPATIBLE MODEL H-W VALVE S86E 844,8440 LH S86H ALL I.I.D. VALVES LH S86F ALL I.I.D. VALVES LH P525 IGNITER MODEL:G60 P526 : LH33CM600 IGNITER MODEL:G67 : LH33CZ003 Use these igniters with the J style pilot burners. Igniters are suitable for panel mounting. The LH33CM600 may be mounted directly on Penn valves EF33CZ206 and 209. The LH33CZ003 can be mounted on Penn valve EF33CZ210 by removing mounting bracket. The LH33CM018 sensor and RM sensor cable are required. 24 volt system. Universal Intermittent Pilot Module Provides ignition sequence, flame rectification and safety shutoff for intermittent pilot central furnaces and heating appliances. For use with single rod or dual rod/remote sense applications. For use with natural or LP gas. Replaces over 300 existing IP modules including Honeywell, Robertshaw, Penn Johnson, Fenwal and others. : P691-S8610U P
15 IGNITERS P527 IGNITION SYSTEMS Solid state igniter creates the ignition voltage required to ignite pilot gas. Provides automatic relight if pilot flame is extinguished while thermostat is calling for heat. Igniter model P531 Solid state igniter for use with glow coils used on 732 and 740 pilot burner. Igniter cycles glow coil and regulates coil voltage to increase coil life. System volts IGNITER MODEL 870 LH33JZ050 PRIMARY POWER CONNECTIONS VOLTS PRIMARY SECONDARY 25 1/4 Q.C. 1/4 Q.C LEADS SPARK PLUG OR 1/4 Q.C. LH33WZ059 NOTE: For use with LH31WZ507 pilot burner and LH33WZ506 electrode. HH71PD001 used as flame sensor and pilot switch. Use with J style pilot. Panel mount. 24 volt. 100% lockout, 120 sec. nominal trial for ignition, with 4 second pilot gas prepurge. MODEL: G770 : LH33CZ007 P1210 The SX611 Ignition Module generates a high-voltage spark and provides a continuous trial for pilot ignition. The SX611 will also automatically try to re-establish the pilot flame should it be extinguished while the thermostat is calling for heat. IGNITER MODEL SX611 LH33EP040 P532 HOT SURFACE IGNITER Designed for use with LH or 013 flame sensor. NORTON MODEL: 271 : LH33ZS004 P534 Universal Hot Surface Ignition Module P4317 Provides easy field-replacement of a wide range of hot surface ignition modules by Honeywell, Robertshaw and White Rodgers. Single rod or remote dual rod rectification type flame sensing. LED signals system lockout, weak flame signal or internal error. Selectable number of ignition trials (1 or 3). Selectable length of trial for ignition (4 or 7 seconds). : P691-S910U P
16 IGNITION SYSTEMS ELECTRODES P535 P536 This electrode is designed for mounting on pilot burner LH31WZ507. Spark igniter LH33WZ505 and flame sensor HH71PD001 are required for complete ignition system. MODEL NO.: 760 : LH33WZ506 Designed specifically for use with LH68005 and LH33JZ053 pilot burners. Locating tabs and locking screw provide accurate location for required spark gap. Spike connection replaces quick connect style. MODEL NO.: AM11 : LH GLOW COILS P538 This is the replacement ignition coil for the 2H pilot burner supplied in the LH68006 pile package. Use with 48DA resistance wire package. PILOT STYLE: 2H NOM. VOLTS: 10 : LH39JZ051 This igniter coil assembly is used with pilot burners LH68005 and LH33JZ053 glow coil voltage source must be limited to maximum of 11 volts. PILOT STYLE: 740 NOM. VOLTS: 10 P539 : LH39JZ020 P537 This sensor is required for use with the LH33CM600 spark igniter. It is designed for mounting on the Penn J style pilot burners. MODEL NO.: Y75 : LH33CM018 This igniter is designed for use with transformer HT01BD024. Refer to appliance manufacturer s instructions for mounting. PILOT STYLE: J NOM. VOLTS: 2.5 Provided with mounting clip. 60 leads with 5/64 thick insulation. P543 : HH79CZ036 WHITE-RODGERS MODEL NO: : LH33EW058 P540 FLAME SENSOR Sensor is designed for use with LH33ZS004 Hot Surface Igniter. MODEL NO.: CE6 : 80 FURNACE USE LH FURNACE USE LH P
17 IGNITION SYSTEMS THERMOCOUPLES TOTALINE THERMOCOUPLE KIT P466 * FOR 30 MILLIVOLT CONTROLS * ADAPTERS TO FIT MOST PILOT BURNERS * INSTALLATION INSTRUCTIONS ON PACKAGE With only three adapter fittings this thermocouple will service most pilot burners old or new, while the selection of lengths assures you of competitive pricing. LENGTH 24 P P P P Most pilot burner applications can be serviced with this thermocouple replacement kit. Thermocouple has nominal 30 millivolt rating and comes with instructions. UNIVERSAL THERMOCOUPLE P671-Q340A Universal Thermocouple REPLACES ALMOST ANY 30 mv THERMOCOUPLE. AVERAGE OPERATING LIFE OF TEN YEARS. BOTTOM LOCK DESIGN ALLOWS FOR ONE HAND INSTALLATION. UNIVERSAL ADAPTER MAKES THIS THE TWO-TO-ONE INSTALLER-PREFERRED THERMOCOUPLE IN INDEPENDENT HVAC SURVEY. PART NUMBER HONEYWELL PART NUMBER DESCRIPTION P671-Q340A-18 A340A1066 Thermocouple 18 P671-Q340A-24 Q340A1074 Thermocouple 24 P671-Q340A-30 Q340A1082 Thermocouple 30 P671-Q340A-36 Q340A1090 Thermocouple 36 P671-Q340A-48 Q340A1108 Thermocouple 48 PILOT SAFETY SWITCHES P544 This auto reset, mercury filled, SPDT pilot switch is used with glow coil and spark ignition systems. Check unit manufacturer s parts list for matching pilot burners. MODEL NO.: 3049 SOLID STATE LOCKOUT TIMER 30 SECOND TRIAL FOR IGNITION MAY BE RESET AFTER 30 SEC. 24 VOLT INPUT MODEL NO.: 990l141 : HH72CH003 TERM. CONN. BULB MOUNTING STYLE CAPIL. LENGTH 1/4 Q.C. LOCKNUT 30 HH71PD001 1/45 Q.C. C RING 30 HH71PD024 P545 This 100% shut-off pilot switch is for use with a nominal 30MV thermocouple. On pilot flame failure, pilot gas and power to main valve are shut off until pilot is manually re-established. MODEL NO.: L62CC TUBE SIZE: 1/4 O.D. : HH71MB066 P548 P547 This auto reset, SPDT pilot switch is used with a nominal 30MV thermocouple. Electrical connections are enclosed. Mount upright in box or on panel. Lighting pilot automatically closes switch. MODEL NO.: L61LL : HH71CC150 Manual reset pilot control which shuts off gas to pilot and main burners when pilot flame fails. Includes pilot gas filter. Use with nominal 30MV thermocouple. MODEL NO.: C591A TUBE SIZE: 1/4 O.D. : EF53FB020 P
18 IGNITION SYSTEMS IGNITION SYSTEM ACCESSORIES RESISTORS LOW PRESSURE SWITCH P550 RESISTANCE WIRE OHMS RESIST- WATTS ANCE 4 20 HT21AU HT21AU D5 Resistors and resistance wire are required on some units to reduce the voltage to ignition glow coils. Refer to unit installation and service instructions. P554 COMBUSTION BLOWER ASSEMBLY RATING PRESS. SETTING 1 AMP 2 WC HK02LB005 1 AMP 6 WC HK02LB018 These low pressure switches are used in ignition circuits to interrupt power when gas pressure is low or gas service to unit is shut down. Switch has 1/8 NPT connection on underside. OHMS LENGTH PER FT DA P551 This package contains stainless resistance wire used in reducing the 24 volt power source to nominal 9-11 volts required on some glow coil igniters. Instruction sheet included. IGNITION LEADS P552 HIGH VOLTAGE IGNITION LEAD Silicone insulated wire for ignition systems where high temperature, moisture resistant ignition lead is required on outdoor equipment. END WIRE CONNECTIONS LENGTH SPK. PLUG/RING TERM MA SPARK PLUG 24 B Q.C./PIN TERM DD NONE QUICK CONNECT 24 RM P CFM MAX. 230 VOLT 1/10 H.P. PSC MOTOR 3450 RPM : 48DA P553 PENN SENSOR LEAD SILICONE-INSULATED COPPER CONDUCTOR FOR USE WITH LH33CM600 SPARK MODULE QUICK CONNECTS Q.C. Q.C. PENN LENGTH TYPE INSULATED NO. STRAIGHT YES Y57JH27 27 RM ST./FLAG NO Y57HJ EGB CFM MAX. 230 VOLT 1/80 H.P SHADED POLE MOTOR 3200 RPM : LA25UZ
19 IGNITION SYSTEMS OIL BURNER COMPONENTS OIL PUMPS P555 SUNSTRAND COMPACT SIZE 5/16 DIA. SHAFT INTEGRAL BLEED FITTING FOR EASY START UP PUMP STAGES PUMP RPM SUNSTRAND HH HH HH HH WEBSTER HH HH HH HH OIL BURNER IGNITION TRANSFORMER P556 WEBSTER COMPACT SIZE 5/16 DIA. SHAFT INTEGRAL BLEED FITTING FOR EASY START UP 115 VOLT 10,000 VOLT SECONDARY 23 MA PRIMARY CONTROLS PROVIDES NON-RECYCLING CONTROL OF AN INTERMITTENT IGNITION OIL BURNER SYSTEM SOLID STATE FLAME SENSING CIRCUIT MOUNTS ON STANDARD 4 x 4 BOX 45 SECOND SAFETY SWITCH TIMING MANUAL RESET REQUIRED P559 AFTER SAFETY SHUTDOWN USE WITH HH79AY060 CAD CELL INTEGRAL TRANSFORMER SUPPLIES 24V POWER TO CONTROL CIRCUIT MODEL NO: R8184G : HH11AZ070 SOLID STATE FLAME SENSING CIRCUIT MOUNTS ON STANDARD 4 x 4 BOX 45 SECOND SAFETY SWITCH TIMING USE WITH HH79AY060 CAD CELL MANUAL RESET REQUIRED P560 AFTER SAFETY SHUTDOWN INTEGRAL 40VA TRANSFORMER PROVIDES CONTROL OF AN INTERMITTENT IGNITION OIL BURNER AND POWER FOR A LOW VOLTAGE COOLING CONTROL CIRCUIT EXTRA Y AND G CONNECTIONS FOR COOLING MODEL NO: R8184M : HH11AZ067 P557 BASE MOUNTING WIDTH LENGTH CENTERS 4-7/16 5-7/16 3-1/4 x 4-1/4 HT08BR /8 5-5/16 3-1/2 x 2-3/4 HT08BR116 COUPLINGS P561 STACK MOUNTED MANUAL RESET FOR USE WITH 2 OR 3 WIRE CONTROL MANUAL TRIP SAFETY SWITCH INTERRUPTED IGNITION MODEL NO: RA117A : HH11AZ040 P558 ENDS LENGTH 1/2 x 5/16 4-1/4 58HH P1208 FAST RESPONSE TIME EASY MOUNTING FOR ACCURATE SIGHTING EASY REPLACEMENT OF PLUG IN CELL CAD CELL HERMETICALLY SEALED MODEL NO: C554 :
20 OIL BURNER COMPONENTS PRIMARY CONTROLS IGNITION SYSTEMS P691-R7184 Interrupted Electronic Oil Primary P691-R818RG Protectorelay/Oil Burner Control P4322 COMPATIBLE WITH HYDRONIC AND FORCED AIR APPLICATIONS. AVAILABLE IN 15 AND 30-SECOND LOCKOUT TIMES. SAFE START CHECK. STATUS INDICATOR LIGHT MONITORS BURNER FLAME STATUS AND SYSTEM LOCKOUT. USES PROVEN FLAME DETECTION AND MONITORING SYSTEMS. OPTIONAL DELAY ON VALVE, BLOWER OFF DELAY MODELS. P4324 PRIMARY CONTROL OPERATES THE OIL BURNER, OIL VALVE, AND IGNITION TRANSFORMER IN A RESPONSE FOR A CALL FOR HEAT FROM THE THERMOSTAT. LOCKOUT INDICATION LIGHTS REDUCE UNNECES- SARY SERVICE CALLS. TAMPER RESISTANT, RUSTPROOF, SCRATCH RESISTANT COVER. HIGHEST PERFORMANCE AND RELIABILITY MAKE IT THE PREFERENCE OF ORIGINAL EQUIPMENT MANUFACTURERS. PART NUMBER HONEYWELL PART NUMBER DESCRIPTION P691-R7184A-P R7184A1026 Interrupted Electronic Oil Primary P691-R7184A-SS R7184A1042 Interrupted Electronic Oil Primary P691-R7184U R7184U1012 Universal Interrupted Electronic Oil Primary P691-R8484G R8184G4009 Protectorelay/Oil Burner Control SOLID-STATE OIL IGNITER P691-S7184A Solid State Oil Igniter THE SOLID STATE OIL IGNITER IS A LINE VOLTAGE IGNITER FOR RESIDENTIAL OIL FIRED BURNERS, FORCED AIR FURNACES, BOILERS, AND WATER HEATERS. MOUNTS ON BURNER HOUSING. DIAGNOSTIC LED INDICATES WHEN THE IGNITER HAS BEEN ENERGIZED. IGNITER CAN BE USED IN AN INTERMITTENT (CONTINUOUS) OR INTERRUPTED MODE OF OPERATION. PART HONEYWELL DESCRIPTION NUMBER PART NUMBER P691-S7184A S7184A1023 Solid State Oil Igniter P
Pilot Burners. Universal Pilot Burners A /08/12
24/08/12 A124-1 Universal Universal Fit - This pilot burner offers adjustable mounting options, flexible hood orientations and the accessories needed for replacement Universal fittings and compact size
More informationPilot Burners. Universal Pilot Burners A /08/12
24/08/12 A124-1 Universal Universal Fit - This pilot burner offers adjustable mounting options, flexible hood orientations and the accessories needed for replacement Universal fittings and compact size
More information36C and 36D Gas Control Product Information
6C and 6D Gas Control Product Information The 6C and 6D combination gas control valves are compact multifunction controls designed to meet requirements for use with Standing Pilot systems and all types
More information36H Gas Control Product Information
Single Stage 36H Two Stage 36H 36H Gas Control Product Information The 36H combination gas control valve is a versatile multifunction control designed to meet the requirements for use with intermittent
More informationRESIDENTIAL ELECTRONIC IGNITION SYSTEMS
Service Application Manual SAM Chapter 630-153 Section 12 RESIDENTIAL ELECTRONIC IGNITION SYSTEMS by Marcus G. Metoyer, Jr., CMS INTRODUCTION The information contained in this publication is generic in
More informationFS-EC4 GSW / John Woods Power Vented Water Heater: FS-GSW1 Lochinvar Boilers
16/12/16 A36 - OEM Direct Replacement Replaces OEM Part Number Carrier: LH33CM018 Penn-Johnson: Y75AS-1 Robertshaw: 10-682 FS-BL3 Evcon/York: 2845-3111 FS-EC4 GSW / John Woods Power Vented Water Heater:
More informationGAS. PFG Section & Base Assembly
PFG Section & Base Assembly 254 Current Service Parts Service Parts Catalog/February 2007 PFG Boiler Parts List Series 1 through 7 Fig # Part Description Series # Price A 312-804-405 Left Hand End Section,
More informationGEMINI GAS CONTROL PRODUCT INFORMATION
GEMINI GAS CONTROL PRODUCT INFORMATION The Gemini (6G) combination gas control valve is a versatile multifunction control designed to meet the requirements for use with non-piloted intermittent ignition
More informationX4 Installation and Operation Manual - POWER FLAME INCORPORATED
7.13.2 Set the burner s combustion air inlet damper to the approximate setting as shown in this manual for the desired firing rate. Also, verify that the correct main orifice is installed in the main orifice
More informationSERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL
SERIES 35-72 120 VAC Microprocessor Based Direct Spark Ignition Control 35.72.03 FEATURES Two Mounting Configurations Open Board With Stand-Off's - saves space and cost Potted - protection for washdown
More informationPT-M90 Automatic Full-Sequence Modulation Gas Control System
PT-M90 PT-M90 Automatic Full-Sequence Modulation Gas Control System PT-M90 Module System Illustration Pucada.Tech M901-0316 Gas Valve (PT-V1C-with step motor) A Profile Dimension: Length(84mm) * Width(40mm)
More informationCGa - Series 1 & 2 Section Assembly Parts
CGa - Series & Section Assembly Parts 0 Part Description Mfr. Mfr. s Part Boiler -0-0 End Section, Left Hand, Cast # -0- End Section, Right Hand, Cast # -0- Intermediate Section, Cast #, -- -- Replacement
More informationCoil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationMT3270 & MT3255 SERIES CONVEYOR OVEN REPLACEMENT PARTS LIST
APRIL 1999 MT3270 & MT3255 SERIES CONVEYOR OVEN REPLACEMENT PARTS LIST MT3255 A Division of G.S. Blodgett Corporation Superseding All Previous s Lists. The Company reserves the right to make substitution
More informationBG1600M Intermittent Pilot Ignition Control
Installation Instructions Issue Date March, 00 BG600M Intermittent Pilot Ignition Control Application The BG600M Intermittent Pilot Ignition Control is a safety control designed for indirect burner ignition
More informationControls and Orifices Pilots
Pilots Robertshaw Pilot Ignition System Eliminates continuous burning pilot. Allows gas to flow/pilot to light only when thermostat calls for heat. Manual reset model has thermal lockout switch. Small
More informationHE, HEII and VHE Section and Base Assembly
HE, HEII and Section and Base Assembly 68 Discontinued Service s HE, HEII and Section and Base Assembly GAS s not listed below are obsolete and no longer available. s listed below may become obsolete.
More informationBGH2UNCNTRLHT-01 Universal Hot Surface Ignition Control
Installation Instructions BGH Issue Date vember 9, 2017 BGH2UNCNTRLHT-01 Universal Hot Surface Ignition Control Application The BASO Gas Products BGH2UNCNTRLHT-01 Universal Series Hot Surface Ignition
More informationMANUFACTURERS INDEX, SECTION 7
7 Controls MANUFACTURERS INDEX, SECTION 7 HONEYWELL............................................... 7-1 7-54 JOHNSON CONTROLS...................................... 7-55 7-66 7 Controls MAXITROL..............................................
More informationG23 Bulletin # September 1998 Supersedes June 1995
ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion
More informationGAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign
3450 RPM Motor, squirrel cage blower, panel with 2 lights (power and main fuel) and control switch Gas electric pilot and gas ignition transformer Leakage test cock, pilot cock and main gas cock Pilot
More informationE Series CE Approved Intermittent Pilot Ignition Control
Installation Instructions Issue Date January 11, 2013 E Series CE Approved Intermittent Pilot Ignition Control Application The E Series CE Approved Intermittent Pilot Ignition Control is a safety control
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationG821L/G822L Series Integrated Function Direct Spark Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G821L/G822L Issue Date 1199 G821L/G822L Series Integrated Function Direct Spark Ignition Controls
More informationIMPORTANT: When ordering parts, please provide the model, gas type and serial number of the oven The identification plate is located on the left side
MT3870 & MT3855G SERIES CONVEYOR OVEN REPLACEMENT PARTS LIST EFFECTIVE SEPTEMBER 6, 2001 BLODGETT OVEN COMPANY, 50 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 860-3700 (800) 331-5842
More informationCoil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationZEPHAIRE G MECHANICAL & SOLID STATE CONTROLS GAS CONVECTION OVENS REPLACEMENT PARTS LIST
ZEPHAIRE G MECHANICAL & SOLID STATE CONTROLS GAS CONVECTION OVENS REPLACEMENT PARTS LIST EFFECTIVE JULY 19, 2005 BLODGETT OVEN COMPANY, 44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802)
More informationProduct Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat
PG8MVA PG8JVA 4 --- WAY MULTIPOISE INDUCED---COMBUSTION GAS FURNACE INPUT CAPACITIES: 70,000 thru 135,000 Btuh SERIES A Product Data multipoise design, through -the-furnace downflow venting, 13 different
More informationWestinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975
Replacement Parts List No. 055227900 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 300 Vintage 0,, 2, 3, 4, 5 Last Manufactured: 975 To find your Daikin Applied parts distributor, call
More informationWestinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975
Replacement Parts List No. 055227700 Revision A 03/2003 Westinghouse Rooftop Heating and Cooling IK 180 Vintage 0, 1, 2, 3, 4 Last Manufactured: 1975 To find your Daikin Applied parts distributor, call
More informationG76x Direct Spark Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G76x Issue Date 0400 G76x Direct Spark Ignition Controls Figure 1: G76x Direct Spark Ignition
More informationTECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence
The Universal TM gas LowNOx series water heaters contain an electronic spark ignition system. The heater is connected to a 120VAC power source required by the transformer. The transformer steps down the
More informationSolid state ignition Beckett CleanCut fuel pump with oil valve Air tube 2-3/4" UL recognized. Beckett Burner Chart
Your One Stop Shop for Parts 115 / 230 Volt Oil Burners.4 to 3 GPH firing rate 6-1/4" Blower fan 115V and 230V 3450 RPM Pump/blower motor Solid state ignition CleanCut fuel pump with oil valve Air tube
More informationORDERING INFORMATION SPECIFICATIONS APPLICATION
ORDERING INFORMATION UNIVERSAL MODELS The ordering part number for the universal model is 82UNIVERSAL. The 82UNIVERSAL comes with remote flame sense active. For internal flame sense, the supplied universal
More informationDFG-50 GAS CONVECTION OVEN REPLACEMENT PARTS LIST
DFG-50 GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL 19, 2012 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are
More informationAll repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change
110 Parts To Your Door Repair Parts Trade Price List (R-16) Effective June 1, 2016 Stock Code Trade Price Jacket Assembly 1 Front Door Panel 2 Front Jacket, Support 3 Cover Door 4 Inner Front Panel 5 Rating
More informationIMPORTANT: When ordering parts, please provide the model, gas type and serial number of the oven The identification plate is located on the back of th
MG3270 & MG-32 CONVEYOR OVEN REPLACEMENT PARTS LIST EFFECTIVE SEPTEMBER 13, 2001 BLODGETT OVEN COMPANY, 50 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone: (802) 860-3700 (800) 331-5842 Fax: (802)
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Product Bulletin Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve The G196 Series valves use the reliable valve body and magnetic operators from
More informationDEXEN INDUSTRIES Inc. GENERAL CATALOG. DEXEN INDUSTRIES Inc.
DEXEN INDUSTRIES Inc. GENERAL CATALOG DEXEN INDUSTRIES Inc. 6003 GAS VALVES 6003-series gas valve is an effective and reliable gas valve for low-btu gas product and application. The product is most commonly
More informationG600 Series Replacement Intermittent Pilot Ignition Controls
Installation Instructions G600 Issue Date 0601 G600 Series ment Intermittent Pilot Ignition Controls Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing
More informationCrest Heating Boilers FBN(L)
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 59 IMG01113 52 65
More informationG861 Series Integrated Function. Direct Spark Ignition Control
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G861 Issue Date 0699 G861 Series Integrated Function Direct Spark Ignition Control Figure 1:
More informationINSTALLATION DATA 712 Series Pilot
INSTALLATION DATA 712 Series Pilot Ignition Systems (FLAME RECTIFICATION) LOCKOUT MODEL 712-005 712-006 712-008 712-009 NON-LOCKOUT MODELS 712-005 712-016 712-017 712-019 712-022 CSA DESIGN CERTIFIED TO
More informationQ35 Series Automatic Vent Damper System
Installation Sheets Manual 121 Energy Conservation and Miscellaneous Kits Section Q Technical Bulletin Q35 Issue Date 0999 Q35 Series Automatic Vent Damper System Figure 1: Q35 Automatic Vent Damper System
More informationSERIES VAC Microprocessor Based Direct Spark Ignition Control with Combustion Blower Relay FEATURES DESCRIPTION
SERIES 35-71 120 VAC Microprocessor Based Direct Spark Ignition Control with Combustion Blower Relay 35.71.02 FEATURES 3 Enclosure Configurations Case and Cover - dust and foreign object protection Open
More informationZEPHAIRE G GAS CONVECTION OVENS REPLACEMENT PARTS LIST
ZEPHAIRE G GAS CONVECTION OVENS REPLACEMENT PARTS LIST EFFECTIVE JANUARY 18, 2012 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationPrimary Controls. Chapter 11. Introduction. Functions of the primary control
Chapter 11 Introduction The safe, automatic operation of an oilheat system is dependent on the interaction between: The thermostat, which opens and closes a circuit based on temperature changes in the
More informationCGi Series 2 Section Assembly
CGi Series 2 Section Assembly 8 0 2 9 9 Current Service Parts CGi Series 2 Section Assembly Part Description Mfr. Mfr. s Part -0-80 End section, left hand, cast #2 Weil-McLain 2-0-82 End section, right
More informationSolid-state ignition Beckett CleanCut fuel pump with oil valve Air tube 2-3/4" UL-recognized
115V / 230V Oil Burners.4 to 3 GPH firing rate 6-1/4" blower fan 115V and 230V 3,450 RPM pump/blower motor Solid-state ignition Beckett CleanCut fuel pump with oil valve Air tube 2-3/4" UL-recognized 8.709-325.0
More informationSAVANNAH EI & DELUXE SYSTEM TROUBLE SHOOTING GUIDE
SAVANNAH EI & DELUXE SYSTEM TROUBLE SHOOTING GUIDE ***PLEASE MAKE SURE TO LEARN THE REMOTE TO THE SYSTEM (REFER TO PG 6) AND CHECK THE BATTERIES FIRST!!! (American Flame AF-4000 Series) Intermittent Pilot
More informationLow BTU Copper Brute TM II Series Models: BWCV0200 BWCV0300 BWCV0400
COMMERCIAL GAS REPLACEMENT PARTS LIST Low BTU Copper Brute TM II Series Models: BWCV0200 BWCV0300 BWCV0400 Effective: March, 2007 ECO 7206 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING
More informationEASY RADIANT WORKS BRAWN SIDE ROAD 22, RR2, WAINFLEET, ON L0S 1V0 PHONE FAX
EASY RADIANT WORKS 12288 BRAWN SIDE ROAD 22, RR2, WAINFLEET, ON L0S 1V0 PHONE 905-899-3473 FAX 905-899-2262 PARTS PRICE LIST January 1, 2011 PART # DESCRIPTION P-1010 AIRSWITCH - ANTUNES N/A #8333513001
More informationOIL BURNERS - 115V / 230V
OIL - 115V / 230V Ergnomically designed to be the most comfortable gun on the market..4 to 3 GPH firing rate 6-1/4" Blower Fan, 115V and 230V 3,450 RPM Pump / Blower Motor Solid-State Ignition Beckett
More informationG72x Series Direct Spark Ignition Controls
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G72x Issue Date 1299 G72x Series Direct Spark Ignition Controls Figure 1: G72x Direct Spark Ignition
More informationSERVICE MANUAL (INTERNATIONAL)
SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1433-000-E, 1434-000-E, 1456, 1457 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804
More informationEASY RADIANT WORKS BRAWN SIDE ROAD, WAINFLEET, ON L0S 1V0 PHONE FAX
EASY RADIANT WORKS 12288 BRAWN SIDE ROAD, WAINFLEET, ON L0S 1V0 PHONE 905-899-3473 FAX 905-899-2262 ILLUSTRATED PARTS LIST January 1, 2017 PART # DESCRIPTION P-1010 AIRSWITCH - ANTUNES N/A #8333513001
More informationUp to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL
N9MSE Product Specifications Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions, Up to 96% AFUE in downflow positions California NOx approved
More informationTable of Contents GF801U Series
FORM NO. GSC-520 GF801U SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES The Sure Comfort line of upflow/horizontal gas furnaces are designed
More informationburners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive.
LAST UPDATE 29/08/12 INSTALLATION INSTRUCTIONS v. 3 UNIT SPECIFICATIONS Main Gas Valve, Pilot Gas Valve Ionisation, Ignition and Flame Monitoring with Common Electrode or Remote Sensor Integrated Cyclic
More informationHigh Efficiency Furnaces
High Efficiency Furnaces Presented By 777 Education and Consulting, Inc. Lansing Michigan Instructor Marcus Butch Metoyer, Jr., CMS, MS, CGP 1 Instructor Bio. HVAC contractor/business owner 40+ years Technical
More information80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G66-495 Supersedes Form No. P66-765 Rev. 3 80PS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] 80% A.F.U.E. UPF/ HORIZONTAL GAS FURNACES The WeatherKing line of upflow/horizontal
More informationW801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )
FORM NO. G66-547 REV. 4 Supersedes Form No. G66-536 Rev. 3 DOWNF GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct spark ignition for reliability and longevity
More informationCooling Capacity CFM in. w.c. (125 Pa)
95.5% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 95.5% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationS8600B,C,H,M; S8610B,C,H,M; S8670D,E,J,K Intermittent Pilot Gas Ignition Control
S8600B,C,H,M; S8610B,C,H,M; S8670D,E,J,K Intermittent Pilot Gas Ignition Control APPLICATION The 8600 family of ignition controls provide ignition sequence, flame monitoring safety shutoff for intermittent
More informationW801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )
FORM NO. G66-549 REV. 3 Supersedes Form No. G66-536 Rev. 3 DOWNFLOW GAS FURNACE Features 80% residential Gas Furnace CSA certified 7 Segment LED all units Direct Spark Ignition System for reliability and
More informationDUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH
FORM NO. GSC-531 REV. 1 Supersedes Form No. GSC-488 Rev. 7 GF902D SERIES Models with Input Rates from 60 to 120 kbtu [17.58 to 35.17 kw] (All Models 92% A.F.U.E. or Above) TWO-STAGE DOWNFLOW/HORIZONTAL
More informationCooling Capacity CFM in. w.c. (125 Pa)
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationCooling Capacity CFM in. w.c. (125 Pa)
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE, all models all positions, California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More informationRheem Classic Plus Series Downflow Gas Furnace
Gas Furnaces Rheem Classic Plus Series Downflow Gas Furnace R801T Downflow Series 80% A.F.U.E. Input Rates 75-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
More informationJ Series Pilot Burners/Y90 Series Inlet Fittings
Product Bulletin Issue Date September 8, 2008 J Series Pilot Burners/Y90 Series Inlet Fittings J Series Pilot Burners/Y90 Series Inlet Fittings are used with Intermittent Pilot Ignition (IPI) and Standing
More information2500/2700 Series Gas Convection Oven
MARKET FORGE 2500/2700 Series Gas Convection Oven 2500/2700 Series Gas Convection Oven 2500 2700 2592 2792 Control Panel Assembly 1 99-4209 Control Panel Assembly Complete (Excluding Thermostat) 2 10-6307
More informationApplies to: Models F, B, FE, and BE with spark pilot
Form CP-F/B-GC (11/17) R8 Obsoletes Form CP-F/B-GC (Version A.2) Gas Conversion Kits and Instructions Applies to: Models F, B, FE, and BE with spark pilot NOTE: Units with standing (match - lit) pilots
More informationGF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)
FORM NO. GSC-515 GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models) TWO STAGE DOWNFLOW GAS FURNACES The Sure Comfort 2-Stage line of downflow gas furnaces
More informationRheem Classic Series Downflow Gas Furnace
Gas Furnaces Rheem Classic Series Downflow Gas Furnace R801S (Downflow) Series 80% A.F.U.E. Input Rates 50-150 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department
More informationSERVICE MANUAL (DOMESTIC)
SERVICE MANUAL (DOMESTIC) IMPINGER CONVEYOR OVENS IMPINGER II - ADVANTAGE SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Phone : (800)
More informationQ345A, Q3451, Q3481, Q348A, Q348B, Q362A, Q373A, Q381A and Q3452 Intermittent Pilot Burner/Igniter-Sensors
QA, Q, Q8, Q8A, Q8B, Q6A, QA, Q8A and Q Intermittent Pilot Burner/Igniter-Sensors FEATURES PRODUCT DATA QA Q,Q8 Q8A,B Q6A QA QA, Q8A, Q8B and QA Intermittent Pilot Burner/Igniter-Sensors are compatible
More informationSECTION 6 PARTS LIST
SECTION FIGURE NO. DESCRIPTION PAGE NO. -1 - - -4-5 - - -8-9 Oven Panels, Window and Legs Exploded Drawing Air Finger Exploded Drawing Control Panel Exploded Drawing Blower and Shroud Exploded Drawing
More informationTROUBLESHOOTING. 1. What is the model and serial number? If you don t know, how old is it? Give description.
TROUBLESHOOTING There is excellent literature on our website: heatec.com. Look under TEC-NOTE. You will find our newest heater manual. This is full of information (complete with great pictures) on our
More informationPARTS & SERVICE MANUAL
PARTS & SERVICE MANUAL Impinger Low Profile Advantage Digital Series (Electric) International Models MODELS: Please note that the model numbering system changed March 2007. The chart below shows the old
More informationSeries 20 Installation Instructions
Series 20 Installation Instructions Installation Instructions and field service checklist Read these instructions carefully. Failure to follow them could result in a fire or explosion causing property
More information(For serial numbers before w/ analog control)
SEQUENCE OF OPERATIONS (For serial numbers before 2038616 w/ analog control) MODEL 1154-000-EA NAT. GAS 230 VAC 50 HZ. 1 PHASE MODEL 1155-000-EA LP GAS 230 VAC 50 HZ. 1 PHASE POWER SUPPLY Electrical power
More informationCrest Heating Boilers FBN(L)
Replacement Parts List S & SERVICE DEMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 2500-6000 69 67 59 62 79 18 26 66 76
More informationReplacement Parts List
Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Copper-Fin II Boilers Water Heaters CH CF 992-2072 50 17
More informationN9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17
92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 92.1% AFUE all models in all positions California NOx approved Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized
More information80% A.F.U.E. DOWNFLOW GAS FURNACES
FORM NO. G66-496 REV. 5 Supersedes Form No. G66-496 Rev. 4 RGLS- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) 80% A.F.U.E. DOWNF GAS FURNACES The
More information15B SERIES II. Models 15B045FE 15B070FE 15B096FE 15B120FE 15B145FE 15B170FE 15B195FE 15B245FE 15B295FE
Models B0FE B00FE B0FE B0FE BFE B0FE BFE BFE BFE B SERIES II Cast Iron Gas Fired Boilers For Forced Hot Water REPAIR AND REPLACEMENT PARTS Ordering Instructions Order Parts through your nearest supplier.
More informationGAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES
FORM NO. G11-487 REV. 1 Supersedes Form No. G11-487 Rev. 8 GAS FURNACES RGLN- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) Annual Fuel Utilization
More informationJANDY HEATERS A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS
JANDY HEATERS Heaters H-58 A QUICK REFERENCE OF MOST COMMONLY REPLACED PARTS E-Z FIND CHART MARK V XE XE SERIES I SERIES I MILLIVOLT MILLIVOLT ELECTRONIC MILLIVOLT ELECTRONIC DM, DR EG ES, EC EPG EPS,
More information2013 MASTER PARTS LIST Effective: 2013-May-01 to 2014-Apr-30
2013 MASTER PARTS LIST Effective: 2013-May-01 to 2014-Apr-30 Table of Contents Parts Breakout 1.0 Trinity Lx150-800....................................... 1 Residential Lx150-400 Commercial Lx500-800 2.0
More informationZone Valves and Parts (Honeywell)
28/11/14 B49 Zone Valves - Two Way Fan Coil Zone Valves and Parts (Honeywell) Two-way Fan Coil Valve, the VU53 high pressure zone valves are used to control the flow of hot or chilled water in commercial
More informationSolstice and Solstice Supreme High Efficiency Gas Fryers SG/SSH Series Service Manual
Solstice and Solstice Supreme High Efficiency Gas Fryers SG/SSH Series Service Manual Notice In the event of problems or questions about your order, contact the Pitco Frialator factory at (603) 225-6684.
More informationac-500 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven
ac-00 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven REPLACEMENT PARTS LIST Effective june, 0 Superseding All Previous Parts Lists. The Company reserves the right to make
More informationTOTALINE PROTECTION CONTROLS
TOTALINE PROTECTION CONTROLS SOLID STATE HEAD PRESSURE CONTROL WITH OPTIONAL HEAT PUMP OVERRIDE Head Pressure Controls Temperature sensitive fan motor control which regulates head pressure at low ambients
More informationFeatures Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design
97311 The S&J 97311 Enclosed burner incinerates harmful emissions from waste gas streams. Typical applications include fermentation off gas piping systems such as anaerobic digesters or landfill gas. This
More informationProduct Data. that this product meets the S 95% AFUE S Two -stage operation
DIRECT VENT 4 -WAY MULTIPOISE CONDENSING GAS FURNACE 95% DOWNFLOW / HORIZONTAL ORIENTATIONS 93.5% UPFLOW ORIENTATION 95% Variable Speed Two -Stage Heating Furnace FLEXIBILITY S Supports two -stage cooling
More informationGAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES
FORM NO. G11-486 REV. 3 Supersedes Form No. G11-486 Rev. 2 GAS FURNACES RGPP- SERIES Models with Input Rates from 50,000 to 150,000 BTU/HR [15 to 44 kw] (U.S. & Canadian Models) ISO 9001:2000 Annual Fuel
More informationAC-500 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST
AC-00 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL 9, 0 Superseding All Previous Parts Lists. The Company reserves the right to
More informationCOS-8G & COS-8GDS COMBI OVENS BCS-G STEAMER CNV-8G CONVECTION OVEN REPLACEMENT PARTS LIST
COS-G & COS-GDS COMBI OVENS BCS-G STEAMER CNV-G CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL 0, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in
More informationDesign and Application Details
Model 400 OVENPAK Gas Page 2105 Design and Application Details OVENPAK s are nozzle-mixing gas burners for many industrial direct-fired applications where clean combustion and high turndown are required.
More informationLANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM
LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM Part 1. General 1.01 Description A. This section describes a candlestick flare system for the combustion of landfill gases. The flare system must be of
More information