AUTO EJECT WP AUTOMATIC POWER LINE DISCONNECT AUTOMATIC EJECTORS. Section 7: Automatic Ejector Systems

Size: px
Start display at page:

Download "AUTO EJECT WP AUTOMATIC POWER LINE DISCONNECT AUTOMATIC EJECTORS. Section 7: Automatic Ejector Systems"

Transcription

1

2 AUTOMATIC EJECTORS v, 15amp NEMA 5-15P 12v, 250v, 15amp NEMA 6-15P 120v, 20amp NEMA 5-20P AUTO EJECT WP AUTOMATIC POWER LINE DISCONNECT CONNECTORS Highly reliable, industrial grade connectors, specially selected to function reliably with the Auto Ejects are provided with each unit. The Dynamic Disconnect is a coupling device wired between an Auto Eject and the vehicle and serves to only connect the A.C. power after the plug has been inserted into the Auto Eject. Upon vehicle startup the Dynamic Disconnect opens the load circuit before ejecting the plug. By providing the time delays on both application and removal of power, no arcing can occur at the connector. Note A.C.power must be present at the shore line connector in order to operate the Dynamic Disconnect ENCLOSURE The enclosure is fabricated from aluminum and contains a cutout and captive fasteners to mate with the Auto Eject mounting screws. Providing protection from road dirt and damage, this unit is suggested for all Auto Eject installations in which the mechanism is exposed to the elements or subject to damage. Outline Drawing: 012 OPTIONAL RETRACTILE CORD The retractile cord is a #12 or 14AWG, 3 conductor cord with an extended length of 20 ft. The Auto Eject connector may be installed at the other end to make this the ideal power input cable. The Auto Eject WP is a power input connector designed to be mounted in the side of a vehicle to permit connecting a 12 Volt D.C., 120 Volt A.C. or 250 Volt A.C. shore line. It comes with a weatherproof cover. The cover is spring loaded to close, preventing water from entering when the shore line is not connected. A solenoid wired to the vehicle s starter or dynamic disconnect is energized when the engine is started. This instantaneously drives the plug from the receptacle. This simple reliable device eliminates forever the broken cables which result when drivers forget to remove the shore line before driving away. The Auto Eject, is new and improved and now contains solid connector pins for longer life. Power output connections are made via a screw terminal strip to permit the installer to easily connect any length of wire. Model # Item Connector WP-120 Auto Eject 15 Amp 120V, 15 Amps WP-012 Auto Eject 15 Amp 12VDC, 250V 15A WP-120 Auto Eject 20 Amp 120V, 20 Amps CP Enclosure Dynamic Disconnect D-14 Retactile Cord 14 Awg D-12 Retractile Cord 12 Awg WEATHERPROOF COVERS AVAILABLE IN RED, WHITE, GRAY, BLUE, SILVER, GOLD, BLACK &YELLOW. SPECIFY COLOR WHEN ORDERING AUTO EJECT. WHEN NOT SPECIFIED, YELLOW COVER WILL BE SUPPLIED. AUTO EJECTS SUPPLIED COMPLETE WITH MATING CONNECTOR.UNITS ALSO AVAILABLE FOR 24 & 42 VOLT ELECTRICAL SYSTEMS. REBUILDING KITS AVAILABLE. Outline Drawing: 011 Warranty: 2 Years TOLL FREE

3 AUTOMATIC EJECTORS SUPER AUTO EJECT DELUXE AUTOMATIC POWER LINE DISCONNECT 120v, 15amp NEMA 5-15P 12v, 250v, 15amp NEMA 6-15P 120v, 20amp NEMA 5-20P CONNECTORS Highly reliable, industrial grade connectors, specially selected to function reliably with the Auto Ejects are provided with each unit. RUBBER CONNECTOR PROTECTOR The protector covers the plug with 1/8" rubber to protect it from impact damage. Nearby vehicles and equipment are also protected. RETRACTILE CORD The retractile cord is a #12 or 14AWG, 3 conductor cord with an extended length of 20 ft. The Auto Eject connector may be installed at the other end to make this the ideal power input cable. COLORS WEATHERPROOF COVERS AVAILABLE IN RED,WHITE, GRAY, BLUE, BLACK & YELLOW SPECIFY COLOR WHEN ORDERING AUTO EJECT. WHEN NOT SPECIFIED, YELLOW COVER WILL BE SUPPLIED. AUTO EJECTS SUPPLIED COMPLETE WITH MATING CONNEC- TOR. UNITS ALSO AVAILABLE FOR 24 & 42 VOLT ELECTRICAL SYSTEMS UPON REQUEST. The Super Auto Eject is a completely sealed automatic power line disconnect. This prevents contamination of the mechanism by road dirt and insures long reliable life even when mounted in the most severe environment. A novel internal switch arrangement closes and opens the 120 volt A.C. circuit after the mating connector is inserted and before the connector is ejected. This eliminates arcing at the connector contacts and assures long contact life. As with all Auto Ejects, the Super Auto Eject is connected to the starter circuit so that ejection occurs when the engine is cranked. BACK WIRE option For installation areas that need the wires to come from the rear of the Auto Eject. Just add -BW to the end of the part number when ordering. Model # Item Connector Super Auto Eject 15 Amp 120 volts AC 15 Amps DC Super Auto Eject 15 Amp 12 VDC, 250VAC 15 Amps Super Auto Eject 20 Amp 120 volts AC 20 Amps D-14 Retractile Cord 14 Awg D-12 Retractile Cord 12 Awg Rubber connector protector REBUILDING KITS AVAILABLE. Outline Drawing: 019 Warranty: 2 Years 49 TOLL FREE

4 AUTOMATIC EJECTORS SUPER 30 AUTO EJECT 30 AMP DELUXE AUTOMATIC POWER LINE DISCONNECT TOTALLY AUTOMATIC OPERATION, NO PUSH BUTTON AUTOMATIC PLUG DETECTOR AUTOMATIC ANTI-ARC DEVICE BUILT-IN NO ARCING OF CONNECTOR MOUNTING PLATE INCLUDED CONNECTORS Highly reliable, industrial grade connectors, specially selected to function reliably with the Auto Ejects are provided with each unit. 30 AMPS 30 AMP CONNECTOR The new Super 30 Auto Eject is a completely sealed automatic power line disconnect. This prevents contamination of the mechanism by road dirt and ensures long reliable life even when mounted in the most severe environment. A novel plug detector closes and opens the 120 volt A.C. circuit after the mating connector is inserted and before the connector is ejected. This eliminates arcing at the connector contacts and assures long contact life. As with all Auto Ejects, the Super 30 Auto Eject is connected to the starter circuit so that ejection occurs when the engine is cranked. BACK WIRE option For installation areas that need the wires to come from the rear of the Auto Eject. Just add -BW to the end of the part number when ordering. COLORS WEATHERPROOF COVERS AVAILABLE IN BLUE,YELLOW, RED, WHITE, GRAY SPECIFY COLOR WHEN ORDERING AUTO EJECT. WHEN NOT SPECIFIED, YELLOW(120V) OR BLUE(250V) COVER WILL BE SUPPLIED. MODEL # ITEM CONNECTOR OPERATING SUPER 30 AUTO EJECT 3PIN 120 volts 12 volts SUPER 30 AUTO EJECT 3PIN 250 volts 12 volts SUPER 30 AUTO EJECT 4PIN 250 volts 12 volts SUPER 30 AUTO EJECT 3PIN 120 volts 24 volts SUPER 30 AUTO EJECT 3PIN 250 volts 24 volts SUPER 30 AUTO EJECT 4PIN 250 volts 24 volts CON-3P PIN CONNECTOR 120 volts CON-3P PIN CONNECTOR 250 volts CON-4P PIN CONNECTOR 250 volts AUTO EJECTS SUPPLIED COMPLETE WITH MATING CONNECTOR, COVER AND MOUNTING PLATE. Outline Drawing: 025 Warranty: 2 Years 51 TOLL FREE

5 WEATHERPROOF COVERS Used With: WP Auto Eject, Wiring Kits, Receptacles WEATHERPROOF COVERS Used With: Super 15 & 20 Auto Eject, and Air Eject WP Adapter kit Used With: Super 30 Auto Eject MODEL 091-3XX MODEL XX MODEL XX Weatherproof covers M ode l N umbe r C olor U se d With N ote s 091-3RD RED W P Auto Eject 091-3YW YELLOW W P Auto Eject Standard color 091-3BL BLUE W P Auto Eject 091-3WH WHITE WP Auto Eject 091-3BLK BLACK W P Auto Eject 091-3GY GRAY W P Auto Eject 091-3SL SILVER W P Auto Eject Display purposes only 091-3GL GOLD W P Auto Eject Display purposes only RD RED Super Auto Eject 15, YW YELLOW Super Auto Eject 15,20 Standard color BL BLUE Super Auto Eject 15, W H W HITE Super Auto Eject 15, BLK BLACK Super Auto Eject 15, GY GRAY Super Auto Eject 15, RD RED Super Auto Eject YW YELLOW Super Auto Eject 30 Standard color for 120v BL BLUE Super Auto Eject 30 Standard color for 250v W H W HITE Super Auto Eject GY GRAY Super Auto Eject 30 NAMEPLATES These nameplates are designed to be installed on the weatherproof covers MODEL # NAMEPLATE TYPE OF COVER 091-NP-01 AIR EJECT 091-3XX 091-NP-02 AIR COMPRESSOR 091-3XX 091-NP-03 BATTERY CHARGER 091-3XX 091-NP-04 BLOCK HEATER 091-3XX 091-NP-05 BATTERY CHARGER, BLOCK HEATER 091-3XX 091-NP-06 BATTERY CHARGER, AIR COMPRESSOR 091-3XX 091-NP-07 B. CHARGER, AIR COMP., B. HEATER 091-3XX 091-NP-KIT ALL NAMEPLATES 091-3XX NP-01 AIR EJECT XX NP-02 AIR COMPRESSOR XX NP-03 BATTERY CHARGER XX NP-04 BLOCK HEATER XX NP-05 BATTERY CHARGER, BLOCK HEATER XX NP-06 BATTERY CHARGER, AIR COMPRESSOR XX NP-07 B. CHARGER, AIR COMP., B. HEATER XX NP-KIT ALL NAMEPLATES XX XX 091-3XX 55 TOLL FREE

6 ACCESSORIES Model 5278C Model 5678C Model 5378C RECEPTACLE, 120V 15AMP This 120 volt male power inlet receptacle is for those installations in which power is brought to the vehicle but an Auto Eject is not desired. Model 5-15P-H CONNECTOR, 120V 15AMP This 120 volt connector may be used with either an Auto Eject or the 5278C receptacle. DC CONNECTOR RECEPTACLE, 12V 15AMP This 12 volt male power inlet receptacle is for those installations in which power is brought to the vehicle but an Auto Eject is not desired. Model 6-15P-H CONNECTOR, 12V 15AMP This 12 volt connector may be used with either an Auto Eject or the 5678C receptacle. RECEPTACLE, 120V 20AMP This 120 volt male power inlet receptacle is for those installations in which power is brought to the vehicle but an Auto Eject is not desired. Model 5-20P-H CONNECTOR, 120V 20AMP This 120 volt connector may be used with either an Auto Eject or the 5378C receptacle. AC CONNECTOR Section 8: Manual Receptacles and Accessories Model This 3 conductor, 15 ampere, twist lock connector is moisture resistant and provides a connection that cannot be accidentally interchanged with any of the standard A.C. connectors. Ideally suited for coupling D.C. to portable equipment. Model WPR-1 This kit contains a 20 amp, 120VAC power input receptacle, weatherproof cover, plastic water tight enclosure and a liquid tight connector for wire diameter min to max. 57 TOLL FREE

AUTO EJECT WP MODEL #: WP-012 MODEL #: WP-120 MODEL #: WP-120 AUTOMATIC SHORELINE DISCONNECT INSTRUCTION MANUAL

AUTO EJECT WP MODEL #: WP-012 MODEL #: WP-120 MODEL #: WP-120 AUTOMATIC SHORELINE DISCONNECT INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO EJECT WP AUTOMATIC SHORELINE DISCONNECT MODEL #: 091-18WP-012 MODEL #: 091-18WP-120 MODEL #: 091-20WP-120 File: IM_091-18wp_reve.indd Rev: E Revised By: SO Date: 09-22-2015 092

More information

Kussmaul Electronics, 170 Cherry Avenue, West Sayville, NY Ph: , Fax: ,

Kussmaul Electronics, 170 Cherry Avenue, West Sayville, NY Ph: , Fax: , 2018 Domestic List - Catalog 121 002-3595-0 Bus Bar - BB-2/8-2 Studs/8 Screws $ 69.50 002-3595-2 Bus Bar - BB-2-2 Studs $ 44.00 002-3595-5 Bus Bar - BB-5-5 Studs $ 80.60 002-3595-8 Bus Bar - BB-8-8 Studs

More information

2018 Domestic Price List - Catalog 121. Section 1 - Battery Chargers and Battery Savers

2018 Domestic Price List - Catalog 121. Section 1 - Battery Chargers and Battery Savers 2018 Domestic List - Catalog 121 Section 1 - Battery Chargers and Battery Savers 5 445-4290-5 LPC 7 Charger $ 255.00 6 091-200-12 LPC 40, w/bar Graph Display $ 936.50 6 091-200-12-194 LPC 40, w/status

More information

Section 1 - Battery Chargers and Battery Savers

Section 1 - Battery Chargers and Battery Savers 2017 Domestic List - Catalog 120 Section 1 - Battery Chargers and Battery Savers 5 445-4290-5 LPC 7 Charger $ 248.30 6 091-200-12 LPC 40, w/bar Graph Display $ 922.60 6 091-200-12-194 LPC 40, w/status

More information

1967 to s 1967, Kussmaul Engineering is born. In 1975, the first Kussmaul Battery Charger is introduced.

1967 to s 1967, Kussmaul Engineering is born. In 1975, the first Kussmaul Battery Charger is introduced. 1967 to 2018 1960-1970 s 1967, Kussmaul Engineering is born. In 1975, the first Kussmaul Battery Charger is introduced. 1980-1990 s In 1985, the first Auto & Air Ejects were developed. 1990 s, the first

More information

SUPER 30 AUTO EJECT 30 AMP MODEL #: AUTOMATIC SHORE LINE DISCONNECT INSTRUCTION MANUAL

SUPER 30 AUTO EJECT 30 AMP MODEL #: AUTOMATIC SHORE LINE DISCONNECT INSTRUCTION MANUAL INSTRUCTION MANUAL SUPER 30 AUTO EJECT AUTOMATIC SHORE LINE DISCONNECT MODEL #: 091-159-30-120 30 AMP File: IM_091-159-30-120_revH.innd Rev: H Revised By: SO Date: 10-15-2015 2 YEAR WARRANTY scan using

More information

SUPER 30 AUTO EJECT -AE

SUPER 30 AUTO EJECT -AE INSTRUCTION MANUAL SUPER 30 AUTO EJECT -AE AUTOMATIC AIR-ELECTRIC SHORELINE DISCONNECT MODEL #: 091-169-30-120 30 Amps Max, 120 Volt Max, 175 PSI Max File: IM_091-169-30-120_reva.indd Rev: B Revised By:

More information

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly Part #: EPO-25A The Larson Electronics EPO-25A explosion proof power outlet provides a durable and secure weatherproof power connection

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Arktite Heavy Duty Circuit Breaking Plugs and Connectors Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.

More information

Instruction Sheet for Powertite Plug, Connector and Receptacle

Instruction Sheet for Powertite Plug, Connector and Receptacle 330087 Instruction Sheet for Powertite Plug, Connector and Receptacle Powertite 200 Amp Pin & Sleeve Receptacles, Cable Connectors and Plugs: NEMA 4X. 600 Volt AC, 250 Volt DC. Wire Recess Diameter:.687.

More information

AUTO REEL -AS MODEL #: AS AUTOMATIC CORD REEL WITH AUTO SAFE INSTRUCTION MANUAL

AUTO REEL -AS MODEL #: AS AUTOMATIC CORD REEL WITH AUTO SAFE INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO REEL -AS AUTOMATIC CORD REEL WITH AUTO SAFE MODEL #: 091-220-20-120-AS INPUT: 120 Volts, 50/60 Hz, 20 Amps File: IM_091-220-20-120-AS_revA.indd Rev: A Revised By: JM Date: 06-09-2015

More information

AE Series Pin and Sleeve Plugs, Connectors and Receptacles Weatherproof 600 Vac, 250 Vdc. Pressure Wire Terminals.

AE Series Pin and Sleeve Plugs, Connectors and Receptacles Weatherproof 600 Vac, 250 Vdc. Pressure Wire Terminals. AE Series Pin and Sleeve Plugs, Connectors and Receptacles 600 Vac, 250 Vdc. Pressure Wire Terminals. Applications Designed to supply power to portable or fixed electrical equipment such as: Welders Generators

More information

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 APJ10487 100 Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac Cooper Crouse-Hinds Catalog Number Manufacturer Description

More information

Plugs and Receptacles: Hazardous Location

Plugs and Receptacles: Hazardous Location U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Plugs and Receptacles Plugs and Receptacles: Hazardous Location Applications Locations where receptacles are used with stationary or portable

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

!!!!! !!!!!!! !!!!! ! 16VAC input voltage, 13.5VDC output voltage BRANCHES COUNTRYWIDE

!!!!! !!!!!!! !!!!! ! 16VAC input voltage, 13.5VDC output voltage BRANCHES COUNTRYWIDE REGAL ELECTRONIC SECURITY EQUIPMENT SUPPLIERS SUPPLY UNITS PS61 Power Supply 1A 13.5VDC SP 1 Amp Output voltage 13.5VDC Grey epoxy coated finish Input voltage 220VAC - 50Hz Fuse and lightning protection

More information

Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere

Instructions for Installation, Operation and Maintenance of: WSRD Interlocked Receptacles 30, 60 & 100 Ampere 331114-1 INSTRUCTION SHEET Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere Read instructions carefully and with full understanding for safe

More information

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Applications Locations where receptacles are used with stationary or portable electrically operated devices such as: Lighting systems Conveyors

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt. Thermwire Freeze Protection Heating Cable Selection Guide Thermwire - Wrap Pipe Freeze Protection Heating Cable Thermwire - Wrap Pre-Assembled Pipe Freeze Protection Heating Cable with Attached Cord &

More information

SUPER AUTO EJECT AUTOMATIC SHORELINE DISCONNECT 3 YEARS WARRANTY. Assembled in the UK by LUDO McGURK TRANSPORT EQUIPMENT LTD WILMSLOW - U.K.

SUPER AUTO EJECT AUTOMATIC SHORELINE DISCONNECT 3 YEARS WARRANTY. Assembled in the UK by LUDO McGURK TRANSPORT EQUIPMENT LTD WILMSLOW - U.K. INSTALLATION GUIDE AND MANUAL SUPER AUTO EJECT AUTOMATIC SHORELINE DISCONNECT 3 YEARS WARRANTY Assembled in the UK by LUDO McGURK TRANSPORT EQUIPMENT LTD WILMSLOW - U.K. A KUSSMAUL ELECTRONICS CO., INC.PRODUCT

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas 1P Arktite Heavy Duty Circuit Breaking s and s Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically operated

More information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number

More information

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC 9419 E US HWY 175, Kemp, TX 75143 Phone: 1 8003696671 Fax: 903.498.3364 Email: sales@larsonelectronics.com Explosion Proof Receptacle Integral Circuit Breaker Class 2 Division 1 30 Amp 480VAC Part #: EPO3W4P30AICB

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

STRAIGHT BLADE PLUGS & CONNECTORS

STRAIGHT BLADE PLUGS & CONNECTORS STRAIGHT BLADE PLUGS & CONNECTORS Quick-thread assembly screws and cord-grip screws come backed-out, ready-to-wire. See-through, thermoplastic terminal chamber for clear view of terminals and wire connections.

More information

AUTO CHARGE LPC SERIES

AUTO CHARGE LPC SERIES INSTRUCTION MANUAL FILE: IM_091-206-12_revB REV: B REVISED BY: THN DATE: 09-17-2012 AUTO CHARGE LPC SERIES MODEL #091-206-12 LPC STANDARD DISPLAY INPUT: 115 volt, 50/60 Hz, 13 amps OUTPUT: 80 AMPERES 3

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1P Arktite Heavy Duty Circuit Breaking s and Receptacles Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically

More information

Marine Products 100 Ampere, 125/250 Volt and 3ØY 120/208 Volt Ship-to-Shore Cable Sets

Marine Products 100 Ampere, 125/250 Volt and 3ØY 120/208 Volt Ship-to-Shore Cable Sets 100 Ampere, 125/250 Volt and 3ØY 120/208 Volt Ship-to-Shore Cable Sets Hubbell Marine was the first to offer 100 amp marine grade devices that are considered second to none. Hubbell developed the standard

More information

3SE03 North American Limit Switches

3SE03 North American Limit Switches General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

HBE 24 SCREW & CRIMP TERMINATED INSERTS

HBE 24 SCREW & CRIMP TERMINATED INSERTS 1 HBE 24 SCREW & CRIMP TERMINATED INSERTS SCREW TERMINATED View from Cable Side CRIMP TERMINATED Panel Cut-Out Contacts Sold Separately These inserts fit in the HBE 24 Series Housings which are on the

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

AUTO CHARGE AMPS DELUXE AUTOMATIC BATTERY CHARGER. Section 1: Single Battery Systems

AUTO CHARGE AMPS DELUXE AUTOMATIC BATTERY CHARGER. Section 1: Single Battery Systems DELUXE AUTOMATIC BATTERY CHARGER Section 1: Single Battery Systems 10 AUTO CHARGE 1000 SINGLE BATTERY SYSTEM AUTOMATIC BATTERY CHARGER & POWER SUPPLY 10 ELEMENT, WATERPROOF BAR GRAPH DISPLAY 18 AMPS TOTAL

More information

Dry Contact Closure Interface

Dry Contact Closure Interface Dry Contact Closure Interface Overview LuXout Shades Dry Contact Closure Contact closure interfaces allows integration of the Automation systems throughout the house. The contact closure interface communicates

More information

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number ACP1034CD Manufacturer Appleton/Oz Gedney

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

RMP SERIES INFORMATION GUIDE

RMP SERIES INFORMATION GUIDE RMP SERIES INFORMATION GUIDE DESCRIPTION & DESIGN FEATURES Applications RMP series connectors can be used wherever high amperage connection of AC or DC power is required. Typical applications are the connection

More information

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed Arktite Circuit Breaking CPS Application: CPS receptacles, angle and straight types, and CPP plugs are used: with portable electrically operated devices such as motor-generator sets, compressors, conveyors,

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC) 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit

More information

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use

More information

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate All Power Pedestals Must Meet the Following: Part I. General: 1.1 General Requirements- A.) Shall be tested and certified

More information

SUPER AUTO EJECT DELUXE COVER WITH DIGITAL DISPLAY

SUPER AUTO EJECT DELUXE COVER WITH DIGITAL DISPLAY INSTRUCTION MANUAL SUPER AUTO EJECT DELUXE COVER WITH DIGITAL DISPLAY MODEL #: 091-55-194X-XXX 194: 40A, 194A: 15A, 194B: 20A, 194C: 80A File: IM_091-55-194X-XXX Rev: A Revised By: PSS/JRN Date: 1-15-2018

More information

VIBRATION SELECTION GUIDE

VIBRATION SELECTION GUIDE INDUSTRIAL PRODUCTS DIVISION VIBRATION SELECTION GUIDE Industrial Products Division Robertshaw Industrial Products Division 1602 Mustang Drive Maryville, TN 37801 Telephone: (865) 981-3100 Fax: (865) 981-3168

More information

Basic Kiln Repair Seminar - Topics. Basic Kiln Repair Seminar - Kiln Components. Basic Kiln Repair Seminar - Available Power

Basic Kiln Repair Seminar - Topics. Basic Kiln Repair Seminar - Kiln Components. Basic Kiln Repair Seminar - Available Power Topics Kiln Components Kiln Components Available Power Cord Sets, Plugs, Receptacles Electrical Controllers Thermocouples Temperature Profiles Test Equipment Wiring Diagrams Practical Troubleshooting Digital

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically operated devices

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable

More information

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 ARL2042 Receptacle Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Descriptions

More information

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components

More information

LPT50BRD (8x11x3 Enclosure)

LPT50BRD (8x11x3 Enclosure) LPT50BRD (8x11x3 Enclosure) TROUBLESHOOTING AND REPAIR MANUAL ALL REPAIRS SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN The LPT50BRD is a field repairable switch. Warranty covers defective parts only.

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles P Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically

More information

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007

PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls. Instruction Sheet PA October 2007 Instruction Sheet PA-00281 October 2007 PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls PS1 Single High and Low Pressure & PS2 Dual Pressure Refrigeration Controls THE FLEXIBLE

More information

HP20 Series. Utilizes a Small #20 Size Shell Accommodates Up to 646 MCM Cable Patents Pending

HP20 Series. Utilizes a Small #20 Size Shell Accommodates Up to 646 MCM Cable Patents Pending HP20 Series Utilizes a Small #20 Size Shell Accommodates Up to 646 MCM Cable Patents Pending RigPower s mission is to create new industry standards in industrial electrical connectors by combining appropriate

More information

THE SUPER 16 AUTO EJECT

THE SUPER 16 AUTO EJECT INSTALLATION GUIDE AND MANUAL 091-182 SUPER 16 AUTO-EJECT THE SUPER 16 AUTO EJECT AUTOMATIC SHORE LINE DISCONNECT 3 YEAR WARRANTY Assembled and Distributed in Europe by LUDO McGURK TRANSPORT EQUIPMENT

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

ELECTRICAL SYSTEM RP-7

ELECTRICAL SYSTEM RP-7 ELECTRICAL SYSTEM RP-7 This section of the manual does not include integral electrical components of the engine. Refer to section Engine RP-1 for details. This section of the manual is divided into three

More information

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity Cam-Lok connectors are the industry standard Cam-Lok

More information

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class

More information

SECTION SECTION. EATON 2014 Arrow Hart Buyers Guide

SECTION SECTION.     EATON 2014 Arrow Hart Buyers Guide F SECTION SECTION 1 EATON 2014 Arrow Hart Buyers Guide FSECTION Cam-lok Single Pole Connectivity Table of contents Product selector guide F-3 NEMA rating system F-4 F-series F-5 E1010 F-6 E1012 F-7 F-series

More information

STRAIGHT BLADE PLUGS & CONNECTORS

STRAIGHT BLADE PLUGS & CONNECTORS STRAIGHT BLADE PLUGS & CONNECTORS Quick-thread assembly screws and cord-grip screws come backed-out, ready-to-wire. See-through, thermoplastic terminal chamber for clear view of terminals and wire connections.

More information

Description. Order TECHNICAL SPECIFICATIONS

Description. Order TECHNICAL SPECIFICATIONS SEMIAUTOMATIC WIRE FEEDERS Semiautomatic, Constant Speed Wire Feeders The are semiautomatic constant speed wire feeders that provide dependable performance and reliable operation, making them ideal for

More information

PF/PFQ. High amperage plugs & receptacles. Features and Ratings p. 132 PF/PFQ A p. 133 PF/PFQ Lugs p. 135 Spare parts p. 137 Dimensions p.

PF/PFQ. High amperage plugs & receptacles. Features and Ratings p. 132 PF/PFQ A p. 133 PF/PFQ Lugs p. 135 Spare parts p. 137 Dimensions p. Features and Ratings p. 132 PF/PFQ 300-600A p. 133 PF/PFQ Lugs p. 135 Spare parts p. 137 Dimensions p. 138 High amperage plugs & receptacles PF and PFQ Series plugs and receptacles are engineered for use

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically operated devices

More information

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2. CONVEYOR COMPONENTS COMPANY 130 Seltzer Road, PO Box 167 Croswell, MI 48422 USA PHONE: (810) 679-4211 TOLL FREE (800) 233-3233 FAX: (810) 679-4510 Email: info@conveyorcomponents.com http://www.conveyorcomponents.com

More information

CLEAN POWER TM CPS Series Operator s Manual

CLEAN POWER TM CPS Series Operator s Manual 12 Test Equipment CLEAN POWER TM CPS Series Operator s Manual Power Supply / Maintenance Charger for 12 Volt Systems The CPS series of power supplies / maintenance chargers are the ultimate in supplying

More information

50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET

50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET R 50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET Transfer Relay Delay 00-00803-400 Dual Input Genset INDUSTRIAL CONTROL EQUIPMENT TYPE 1 Shore Power Rating: 120/240VAC 60HZ 1 Phase 50A/Pole Generator

More information

Arrow Hart industrial grade power lock plugs, connectors and receptacles

Arrow Hart industrial grade power lock plugs, connectors and receptacles Arrow Hart industrial grade power lock plugs, connectors and s Description 2-pole, 3-wire grounding 3-pole, 3-wire non-grounding 3-pole, 4-wire grounding 20A, 125V/AC; 20A, 250V/DC; 30A, 480V/AC; 30A,

More information

VWSQ SERIES 30 AMP INTERLOCKED SWITCH RECEPTACLES

VWSQ SERIES 30 AMP INTERLOCKED SWITCH RECEPTACLES INSTALLATION, OPERATION & MAINTENANCE DATA SHEET VWSQ SERIES 30 AMP INTERLOCKED SWITCH RECEPTACLES VWSQ SERIES INTERLOCKED SWITCHED RECEPTACLES TO BE USED IN ENCLOSURE TYPES 3, 4 & 4X VWSQ SERIES 30 AMP

More information

LPT50BRD (8x8x4 Enclosure)

LPT50BRD (8x8x4 Enclosure) LPT50BRD (8x8x4 Enclosure) TROUBLESHOOTING AND REPAIR MANUAL ALL REPAIRS SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN The LPT50BRD is a field repairable switch. Warranty covers defective parts only.

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

LN-8. Semiautomatic Wire Feeder LINCOLN ELECTRIC

LN-8. Semiautomatic Wire Feeder LINCOLN ELECTRIC LN-8 Semiautomatic Wire Feeder LN-8 WIRE FEEDER LN-8 shown with DC-600 power source, K1524-1 universal wire reel stand, K1557-1 swivel platform and a Magnum 400 gun and cable assembly. The LN-8 is a semiautomatic

More information

Weather Protective Devices

Weather Protective Devices Weather Protective Devices N Industrial Specification Grade Receptacle Covers N-1, N-2 Weather Protective Devices N-3 Power-Lock Receptacles and Flanged Inlets with Weather Protective Lift Lids N-4 50

More information

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL LPC 20 LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-207-12 INPUT: 120 Volt, 50/60 Hz, 7 Amps OUTPUT: 20 Amps File:

More information

Single pole connectors

Single pole connectors Cam-Lok J-Series E1016 receptacles Cable Size #6 AWG 250 MCM 600V AC/DC, Up to 400A Continuous NEMA 3R J-Series E1016, elastomeric, threaded stud Double cam principle provides a positive, vibration-proof

More information

Amphenol 67 and 165 Series Miniaturized Standard Connectors

Amphenol 67 and 165 Series Miniaturized Standard Connectors Amphenol 67 and 165 Series Miniaturized Standard Connectors 12-023-6 Amphenol Table of Contents Page No. Amphenol 67 Series Minni E General Information, Design Characteristics, Customer Options.........................

More information

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C.

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C. INSTRUCTION MANUAL FILE: IM_091-141_Rev_B DATE: 10-02-03 LOAD MANAGER P A battery protector for vehicles with equipment that Is operated with the engine not running MODEL# 091-141 INPUT: 12 Volts D.C.

More information

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals. 8 SERIES /8 Ported Air Valves 1/ Ported Air Valves /8 & 1/ 1, 1A, 1B & 8 Series Note! Spring return & spring centered models NOT suitable for dry air service. Features & Way - Position. Way - &. operator

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center Newport Harbor Mate Dimensions Height: 14.50" (368.30 mm) Width: 10.50" (266.70 mm) Depth: 10.40" (264.16 mm) Newport Harbor Mate Utility Center Diagram 2.77" Approximate Weight: 11 lbs. (5.0 kg) 10.31"

More information

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles ENR Value Series Dead Front Interlocked Circuit Breaking s Cl. I, Div. & 2, roups B, C, D Cl. II, Div. & 2, roups F, Cl. III, 7BCD, 9F, 2 Dust-Ignitionproof Raintight et Locations ENP Plugs Applications:

More information

30A SMART ENERGY MANAGEMENT SYSTEM TM

30A SMART ENERGY MANAGEMENT SYSTEM TM 30 Amp EMS Display Panel P/N 00-00903-030 (Black) 30 Amp EMS Distribution Panel P/N 00-0091-000 CAUTION The 30A SMART EMS is a centralized power switching, fusing, and distribution center. Power from the

More information

Arktite Plugs, Receptacles, and Connectors

Arktite Plugs, Receptacles, and Connectors Arktite Plugs, Receptacles, and Connectors Arktite Plugs, Receptacles, and Connectors THE COOPER CROUSE-HINDS STANDARD Put a century of standard-setting experience to work for you. For more than a century,

More information

Sealed Sensor Connector (SSC) System

Sealed Sensor Connector (SSC) System Introduction Product Features Robust housing, glass filled PBT for high temperature applications Terminal Position Assurance (TPA) to assure proper position of contact in housing Damage protected internal

More information

Mizer Single Pump and Starter Box

Mizer Single Pump and Starter Box Mizer Single Pump and Starter Box Table of Contents Line Diagram... 2 Overview... 3 Booster Pump Specifications... 3 Water... 3 Electrical... 3 Models... 3 Mounting... 4 Electrical... 6 Motor Rotation...

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

3SE03 North American Limit Switches

3SE03 North American Limit Switches General Information Features Modular plug-in Prewired receptacle with pin connector Prewired cable Features UL Listed, CSA Certified. UL File: E47512 All Metal Captive Screws. Keyed, Four-Directional Head.

More information

PF/PFQ. High amperage plugs & receptacles. Features and Ratings p. 128 PF/PFQ A p. 129 PF/PFQ Lugs p. 131 Spare parts p. 133 Dimensions p.

PF/PFQ. High amperage plugs & receptacles. Features and Ratings p. 128 PF/PFQ A p. 129 PF/PFQ Lugs p. 131 Spare parts p. 133 Dimensions p. Features and Ratings p. 128 PF/PFQ 300-600A p. 129 PF/PFQ Lugs p. 131 Spare parts p. 133 Dimensions p. 134 High amperage plugs & receptacles Watch the PF video and other product videos at meltric.com/video

More information

The Quality of Light TM. MODEL: SSI-600-PDC Controller Operation Manual. Metaphase Technologies Inc. JAN-09

The Quality of Light TM. MODEL: SSI-600-PDC Controller Operation Manual. Metaphase Technologies Inc. JAN-09 The Quality of Light TM MODEL: SSI-600-PDC Controller Operation Manual For packaging purposes the line light and controller are shipped separately. The user must make the connection currently according

More information

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903) ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX 75568 (903) 897-0737 fax (903) 897-0740 Pedestal Starter-Disconnect Pedestal Starter Controller Installation Instructions

More information

Shore Power Adapter...3. Wiring Devices...9 G W NEMA 5-15/20R. 30A Power Cord...1 Shore Power Adapter...3. Y Adapter A Shore Power Inlet...

Shore Power Adapter...3. Wiring Devices...9 G W NEMA 5-15/20R. 30A Power Cord...1 Shore Power Adapter...3. Y Adapter A Shore Power Inlet... Conntek strives to produce only the highest quality cords and accessories on the market, and our Shore Power series is no different. eather resistant plugs / s, durable jacket materials, and numerous other

More information

POWERLINE 2000 Energy Management System TM

POWERLINE 2000 Energy Management System TM Display Panel TM The PowerLine 00 EMS is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed in the standard main distribution

More information

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,

More information

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. NEC EBR Receptacle:

More information

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions.

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions. Plugs & receptacles Cam-Lok single pole connectivity Cam-Lok Single pole connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok single pole connectivity

More information

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +

More information