INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C.

Size: px
Start display at page:

Download "INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C."

Transcription

1 INSTRUCTION MANUAL FILE: IM_ _Rev_B DATE: LOAD MANAGER P A battery protector for vehicles with equipment that Is operated with the engine not running MODEL# INPUT: 12 Volts D.C. MODEL# INPUT: 24 Volts D.C. 3 YEAR WARRANTY

2 INTRODUCTION The model LOAD MANAGER P is designed to disconnect loads when the battery voltage drops below a certain threshold. In addition a "Shutdown Timer" is provided so that the load is disconnected 1 to 2 hours after the engine is shutdown. This provides the ideal control for the computer or radio in police cars, rescue vehicles, command vehicles or any application where these devices might be used with the engine not running. If the operator forgets to shut down the computer or radio, the battery is protected, as the Load Manager P will turn off the power before the battery is drained. 12VDC Operation: The factory pre-set voltage for shutdown is 11.0 volts, but can be potentiometer adjusted up to volts. The factory pre-set shutdown time is 1 hour (when engine is not running). This time can also be potentiometer adjusted up to 2 hours. 24VDC Operation: The factory pre-set voltage for shutdown is 22.0 volts, but can be potentiometer adjusted from to volts. The factory pre-set shutdown time is 1 hour (when engine is not running). This time can also be potentiometer adjusted up to 2 hours. Shutdown Timer: Enabled (factory default) when diode CR4 is installed on Printed Circuit Board Assembly (refer to Figure 3). Disabling the Shutdown Timer by removing CR4 will allow load power supply regardless of engine running/not running status. The load will, however, still be managed as a function of vehicle battery voltage per voltage shutdown described above. The Load Manager Model Number will be followed by "DIS" if the Shutdown Timer is disabled at the factory per customer order.

3 PRINCIPLES OF OPERATION The Load Manager P is basically a low voltage disconnect which removes power from the load when the voltage sensed drops below the preset threshold of 11.0 volts for 12VDC operation and 22.0 volts for 24VDC operation. A starter override is provided to prevent disabling the load while the engine is cranking. This eliminates re-booting the computer if cranking the engine drops the battery voltage below the threshold. When the device detects that the engine is not running a timer is started. After the set time has elapsed the load will be deenergized. If during the timing cycle, the battery voltage drops below its set point, the load will be immediately deenergized. Starting the engine at any time during the timing cycle will reset the timer. A block diagram appears in figure 1. FACTORY ADJUSTED TO 1 HOUR TIME PRE-SET ADJUST TRIMMER TRUE IF T > TSp AND ENGINE IS OFF ENGINE OFF SENSOR TIMER 1 HOUR TO 2 HOURS STARTER SWITCH ON TRUE WHILE ENGINE IS CRANKING V Bat VOLTAGE PRE-SET ADJUST TRIMMER VOLTAGE DETECTOR TRUE IF V < V Bat Sp POWER RELAY IF THIS LINE IS TRUE, THEN THE POWER RELAY IS ENERGIZED Figure 1 BLOCK DIAGRAM, LOAD MANAGER P

4 INSTALLATION WIRING: Figure 2 illustrates the wiring of the Load Manager P. Wire the unit using the wire gauges shown in figure 2. #12 AWG, RED NO #12 AWG, ORANGE RADIO & COMPUTER LOADS - C SIZE FUSE FOR 25% HIGHER THAN ACTUAL LOAD #12 AWG, BLACK FROM 12 or 24 VOLT BATTERY #20 AWG, RED #20 AWG, BLACK FROM STARTER SWITCH (0PTIONAL) #20 AWG, YELLOW Figure 2 INSTALLATION WIRING, LOAD MANAGER P ALIGNMENT: Refer to Figure 3 for all component locations and measurement points. 12VDC Operation: R102 is normally set maximum counter-clockwise for an 11.0 volt threshold. R102 can be adjusted in a clockwise direction to obtain a higher threshold voltage. Maximum clockwise is volts. 24VDC Operation: R102 is normally set approximately 70% of full counter-clockwise for a 22.0 volt threshold. R102 can be adjusted in a clockwise direction to obtain a higher threshold voltage. Maximum clockwise is volts, maximum counterclockwise is 21.25VDC. R103 is normally set maximum counter-clockwise for a 1-hour time threshold. R103 can be adjusted in a clockwise direction to obtain a longer time threshold. Maximum clockwise is 2 hours.

5 VOLTAGE ADJUST, R102, 12VDC MAX CCW = 11 VOLTS (NORMAL) MAX CW = VOLTS VOLTAGE ADJUST, R102, 24VDC MAX CCW = VOLTS MAX CW = VOLTS 70% MAX CCW = 22.0 VOLTS (NORMAL) Shutdown Timer Enable Diode A3 R3 C1 U1 CR4 C3 R4 C2 TIME ADJUSTMENT R103 MAX. CCW = 1 HOUR (NORMAL) MAX. CW = 2 HOURS A1 Q1 C8 R1 VOLTS R102 R5 A2 R8 R103 U2 TIME R101 V REF C11 U3 R7 R2 R9 C10 C13 C6 B CR1 C9 RUN Q2 C5 R11 S1 TEST K1 C12 CR3 C7 R6 CR2 KUSSMAUL ELECTRONICS A4 R10 R12 J1 Figure 3 ALIGNMENT & PROGRAMMING, LOAD MANAGER P

6 SPECIFICATION AND OUTLINE Temperature Environment: 0 to 50 deg C. Main Input Power: Input Current: Load Output Power: 12VDC Battery, [24VDC Battery] 90 [40] milliamperes, relay ON 9 [5] milliamperes, relay OFF 30 amperes maximum. 30 Amperes maximum] Low Voltage Dropout of Load: 11.0 to volts (potentiometer adjustable, Factory set for 11 volts). [21.25 to volts (potentiometer adjustable, Factory set for 22.0 volts)] Load Power Restoration Voltage:.5 [.75] volt higher than the Low Voltage dropout of load. Time Dropout of Load: Starter Inhibit: Weight: 1 to 2 hours (potentiometer adjustable, factory set for 1 hour). The Load will not drop out due to low voltage while the engine is being started. 0.5 lbs /16" DIA , OUTLINE, LOAD MANAGER P

7 INSTALLATION RECORD & WARRANTY Date Installed Installed By Vehicle Identification Vehicle Owner WARRANTY All products of Kussmaul Electronics Company Inc. are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects that become apparent in normal use within 3 years from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid. Kussmaul Electronics Company, Inc. shall have no liability for damages of any kind to associated equipment arising from the installation and /or use of the Kussmaul Electronics Company, Inc. products. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others.

AUTO ISOLATOR I AN AUTOMATIC LOSSLESS BATTERY ISOLATOR FOR DUAL BATTERY SYSTEMS

AUTO ISOLATOR I AN AUTOMATIC LOSSLESS BATTERY ISOLATOR FOR DUAL BATTERY SYSTEMS INSTRUCTION MANUAL AUTO ISOLATOR I AN AUTOMATIC LOSSLESS ISOLATOR FOR DUAL SYSTEMS MODEL #: 091-139-2-12 VOLTAGE: 12 VDC OUTPUT: 12 VOLTS, 3 AMPS PARALLELING : 200 AMPS File: IM-091-139-2-12 Rev: revc

More information

INSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

INSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. FILE: 091-84.pmd DATE: 9-21-07 INSTRUCTION MANUAL AUTO THROTTLE 1 MODEL #091-84 AN AUTOMATIC HIGH IDLE CONTROLLER 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. 170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796

More information

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL INSTRUCTION MANUAL FILE: 091-106-150-XX-120 DATE: 10-2-2009 REV: A INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 MODEL # 091-106-150-XX-120 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. 170

More information

DUAL 12 Volt-10 Amp AUTOMATIC BATTERY CHARGER

DUAL 12 Volt-10 Amp AUTOMATIC BATTERY CHARGER FILE: 091-145 DATE: 01-02-02 INSTRUCTION MANUAL DUAL 12 Volt-10 Amp AUTOMATIC BATTERY CHARGER MODEL #091-145 INPUT: 120 Volts, 50/60 Hz AC OUTPUT 1: 12 Volts, DC, Isolated OUTPUT 2: 12 Volts, DC, Isolated

More information

AUTO PUMP STATUS CENTER

AUTO PUMP STATUS CENTER INSTRUCTION MANUAL AUTO PUMP STATUS CENTER VOLTAGE & PRESSURE MODEL #: 091-198-12-PP File: IM_091-198-12-PP_revD.indd Rev: D Revised By: MFG/PSS Date: 1-30-2015 3 YEAR WARRANTY scan using your mobile device

More information

INSTRUCTION MANUAL AUTO CHARGE MODEL # OUTPUT: 15 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

INSTRUCTION MANUAL AUTO CHARGE MODEL # OUTPUT: 15 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. File: 091-56-12 rev b.pmd Rev: B, Date: 4-1-10 INSTRUCTION MANUAL AUTO CHARGE 1000 AUTOMATIC BATTERY CHARGER MODEL #091-56-12 INPUT :115 volt, 50/60 Hz, 3.5 amps OUTPUT: 15 AMPERES 3 YEAR WARRANTY KUSSMAUL

More information

AUTO CHARGE 1200 PUMP PLUS

AUTO CHARGE 1200 PUMP PLUS FILE: 091-193-12.pmd REV: B REVISED BY: MFG DATE: 2-14-2011 INSTRUCTION MANUAL AUTO CHARGE 1200 PUMP PLUS AUTOMATIC BATTERY CHARGER MODEL #091-9-1200 INPUT: 115 volt, 50/60 Hz, 10 amps OUTPUT: 40 AMPERES

More information

BATTERY SAVER LR HO with USB LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS

BATTERY SAVER LR HO with USB LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS FILE: IM_091-195-12-USB_revB1 REVISED BY: PSS DATE: 06-28-2013 INSTRUCTION MANUAL BATTERY SAVER LR HO with USB LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS MODEL #091-195-12-USB

More information

SUPER AUTO EJECT DELUXE COVER WITH DIGITAL DISPLAY

SUPER AUTO EJECT DELUXE COVER WITH DIGITAL DISPLAY INSTRUCTION MANUAL SUPER AUTO EJECT DELUXE COVER WITH DIGITAL DISPLAY MODEL #: 091-55-194X-XXX 194: 40A, 194A: 15A, 194B: 20A, 194C: 80A File: IM_091-55-194X-XXX Rev: A Revised By: PSS/JRN Date: 1-15-2018

More information

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER INSTRUCTION MANUAL FILE: IM_091-120-XX-XX-(XXX)(XX)_revA.P65 REV: A REVISED BY: PSS DATE: 07-19-13 AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER R MODEL #091-120-XX-XX-(XXX)(XX) 3 YEAR WARRANTY 170 Cherry

More information

AUTO CHARGE LPC SERIES

AUTO CHARGE LPC SERIES INSTRUCTION MANUAL FILE: IM_091-206-12_revB REV: B REVISED BY: THN DATE: 09-17-2012 AUTO CHARGE LPC SERIES MODEL #091-206-12 LPC STANDARD DISPLAY INPUT: 115 volt, 50/60 Hz, 13 amps OUTPUT: 80 AMPERES 3

More information

AUTO EJECT WP MODEL #: WP-012 MODEL #: WP-120 MODEL #: WP-120 AUTOMATIC SHORELINE DISCONNECT INSTRUCTION MANUAL

AUTO EJECT WP MODEL #: WP-012 MODEL #: WP-120 MODEL #: WP-120 AUTOMATIC SHORELINE DISCONNECT INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO EJECT WP AUTOMATIC SHORELINE DISCONNECT MODEL #: 091-18WP-012 MODEL #: 091-18WP-120 MODEL #: 091-20WP-120 File: IM_091-18wp_reve.indd Rev: E Revised By: SO Date: 09-22-2015 092

More information

INSTRUCTION MANUAL REMOTE OUTPUT: 40 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

INSTRUCTION MANUAL REMOTE OUTPUT: 40 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. FILE: 091-53-12-REMOTE rev g.pmd REV: G 04-01-10 MFG INSTRUCTION MANUAL AUTO CHARGE 1200 REMOTE AUTOMATIC BATTERY CHARGER MODEL #091-53-12-REMOTE INPUT :115 volt, 50/60 Hz, 10 amps OUTPUT: 40 AMPERES 3

More information

AUTO PUMP 12V MODEL #: V 12 VOLT DC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. INPUT: Volts DC, 11 Amps OUTPUT: 100 PSI Max

AUTO PUMP 12V MODEL #: V 12 VOLT DC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. INPUT: Volts DC, 11 Amps OUTPUT: 100 PSI Max INSTRUCTION MANUAL AUTO PUMP 12V 12 VOLT DC AIR COMPRESSOR SYSTEM MODEL #: 091-9-12V INPUT: 10-15 Volts DC, 11 Amps OUTPUT: 100 PSI Max File: IM_091-9-12v_revC1.indd Rev: C1 Revised By: PSS/JRN Date: 08-16-2017

More information

AUTO CHARGE 11HO PIM AUTOMATIC BATTERY CHARGER

AUTO CHARGE 11HO PIM AUTOMATIC BATTERY CHARGER BOOK# 091-11HO-PIM-1 INSTRUCTION MANUAL AUTO CHARGE 11HO PIM AUTOMATIC CHARGER MODEL #091-11HO-PIM NOTE : This charger is designed for vehicles with dual batteries and negative ground. INPUT :115 volts,

More information

AUTO-PUMP 12V HP-VER FOR VERTICAL MOUNT ONLY MODEL #: V-HP-VER 12VDC HIGH OUTPUT AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL

AUTO-PUMP 12V HP-VER FOR VERTICAL MOUNT ONLY MODEL #: V-HP-VER 12VDC HIGH OUTPUT AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO-PUMP 12V HP-VER 12VDC HIGH OUTPUT AIR COMPRESSOR SYSTEM FOR VERTICAL MOUNT ONLY MODEL #: 091-9-12V-HP-VER INPUT :10-15 volt, 11 amp OUTPUT :125 PSI MAXIMUM File: 091-9-12V-HP-VER_revA

More information

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL PUMP PLUS 2000 PLC AUTOMATIC DUAL OUTPUT BATTERY CHARGER Supplied with Dual Bar Graph Display MODEL #: 091-237-12-PP INPUT: 120 Volt, 60 Hz, 3.5 Amps OUTPUT BATTERY 1 and 2: 15 or 18

More information

INSTRUCTION MANUAL MODEL # NOTE : This charger is designed for vehicles with dual batteries and negative ground.

INSTRUCTION MANUAL MODEL # NOTE : This charger is designed for vehicles with dual batteries and negative ground. INSTRUCTION MANUAL FILE: 091-9-2000.P65 DATE: 4-23-2000 REV. A AUTO CHARGE 2000 PUMP-PLUS AIR COMPRESSOR / BATTERY CHARGER MODEL #091-9-2000 NOTE : This charger is designed for vehicles with dual batteries

More information

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO CHARGE 12 HO AUTOMATIC SINGLE OUTPUT BATTERY CHARGER MODEL #: 091-170-6 MODEL #: 091-170-12 MODEL #: 091-170-24 File: IM_091-170-xx_revd.indd Rev: D Revised By: MFG Date: 10-23-2013

More information

SUPER 30 AUTO EJECT 30 AMP MODEL #: AUTOMATIC SHORE LINE DISCONNECT INSTRUCTION MANUAL

SUPER 30 AUTO EJECT 30 AMP MODEL #: AUTOMATIC SHORE LINE DISCONNECT INSTRUCTION MANUAL INSTRUCTION MANUAL SUPER 30 AUTO EJECT AUTOMATIC SHORE LINE DISCONNECT MODEL #: 091-159-30-120 30 AMP File: IM_091-159-30-120_revH.innd Rev: H Revised By: SO Date: 10-15-2015 2 YEAR WARRANTY scan using

More information

AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER

AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER File: 091-165-12-DV_revD.PDF Rev: D, Date: 02-25-16 INSTRUCTION MANUAL AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER MODEL #091-165-12-DV INPUT: 115 or 230VAC, 50/60Hz OUTPUT: 13.2VDC (nom.), 12 Amperes

More information

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL PUMP PLUS 1000 PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-215-12-PP INPUT: 120 Volt, 60 Hz, 3.5 Amps OUTPUT BATTERY 1 and 2: 15

More information

INSTRUCTION MANUAL ENGINE IDLER MODEL # VOLTGAE MONITOR MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

INSTRUCTION MANUAL ENGINE IDLER MODEL # VOLTGAE MONITOR MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. FILE: 091-84.P65 date: 06-02-99 INSTRUCTION MANUAL ENGINE IDLER MODULE PART OF A HIGH IDLE SYSTEM ENGINE IDLER MODEL #091-84-005 VOLTGAE MONITOR MODEL #091-84-004 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO.,

More information

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY INSTRUCTION MANUAL AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM MODEL #: #:091-9B-1 091-9B-1 INPUT :120 volt, 50/60 Hz, 1.8 AMPS OUTPUT: 100 PSI MAXIMUM File: 091-9B-1_revA1_GEN3 Rev: A1 Revised By:PSS/JRN

More information

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax: INSTRUCTION MANUAL AUTO CHARGE DUAL AUTOMATIC DUAL OUTPUT BATTERY CHARGER MODEL #: 091-145-12 INPUT: 120 Volt, 50/60 Hz, 3.5 Amps OUTPUT BAT 1: 10 Amps OUTPUT BAT 2: 10 Amps File: IM_091-145-12_revb.indd

More information

AUTO CHARGE 12HO-PIM AUTOMATIC BATTERY CHARGER

AUTO CHARGE 12HO-PIM AUTOMATIC BATTERY CHARGER BOOK# 091-12HO-1 INSTRUCTION MANUAL AUTO CHARGE 12HO-PIM AUTOMATIC BATTERY CHARGER MODEL #091-12HO-PIM NOTE : This charger is designed for vehicles with a single battery system INPUT :115 volt, 50/60 Hz,

More information

AUTO REEL -AS MODEL #: AS AUTOMATIC CORD REEL WITH AUTO SAFE INSTRUCTION MANUAL

AUTO REEL -AS MODEL #: AS AUTOMATIC CORD REEL WITH AUTO SAFE INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO REEL -AS AUTOMATIC CORD REEL WITH AUTO SAFE MODEL #: 091-220-20-120-AS INPUT: 120 Volts, 50/60 Hz, 20 Amps File: IM_091-220-20-120-AS_revA.indd Rev: A Revised By: JM Date: 06-09-2015

More information

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO CHARGE 4000 LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER Unit supplied with this display MODEL #: 091-89-12 INPUT: 120 Volt, 50/60 Hz, 5 Amps OUTPUT: 45 Amps File:

More information

SUPER 30 AUTO EJECT -AE

SUPER 30 AUTO EJECT -AE INSTRUCTION MANUAL SUPER 30 AUTO EJECT -AE AUTOMATIC AIR-ELECTRIC SHORELINE DISCONNECT MODEL #: 091-169-30-120 30 Amps Max, 120 Volt Max, 175 PSI Max File: IM_091-169-30-120_reva.indd Rev: B Revised By:

More information

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax: INSTRUCTION MANUAL AUTO CHARGE 4000 AUTOMATIC DUAL OUTPUT BATTERY CHARGER MODEL #: 091-89-12 INPUT: 120 Volt, 50/60 Hz, 8 Amps OUTPUT BATTERY CHARGER: 40 Amps OUTPUT BATTERY SAVER: 5 Amps File: IM_091-89-12_reve.indd

More information

BATTERY SAVER LOW RIPPLE HO

BATTERY SAVER LOW RIPPLE HO INSTRUCTION MANUAL BATTERY SAVER LOW RIPPLE HO LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS MODEL #: 091-195-12 INPUT: 120 Volt, 50/60 Hz, 4.5 Amps RMS OUTPUT: 13.2 Volts DC,

More information

INSTRUCTION MANUAL CAUTION

INSTRUCTION MANUAL CAUTION FILE: IM_091-128-12E-40-115 Rev B., 2-16-2006 INSTRUCTION MANUAL AUTO CHARGE ODY q AUTOMATIC BATTERY CHARGER MODEL #091-128-12E-40-115 for ODYSSEY AGM BATTERIES CAUTION This charger is calibrated to the

More information

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO CHARGE D2 AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-74-12 INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY 1

More information

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL LPC 40 LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-200-12 INPUT: 120 Volt, 50/60 Hz, 5 Amps OUTPUT: 40

More information

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL LPC 20 LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-207-12 INPUT: 120 Volt, 50/60 Hz, 7 Amps OUTPUT: 20 Amps File:

More information

AUTO CHARGE D PUMP PLUS

AUTO CHARGE D PUMP PLUS INSTRUCTION MANUAL AUTO CHARGE D PUMP PLUS AUTOMATIC DUAL OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-9-DPP INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY:

More information

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO CHARGE 11 AUTOMATIC BATTERY CHARGER U.L. Configuration MODEL #: 091-11-XX NOTE : This charger is designed for vehicles with dual batteries and negative ground. CAUTION This unit

More information

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT: INSTRUCTION MANUAL AUTO-PUMP HP 240 VAC HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT: 220-240 Vac, 50 Hz, 1.3 Amps 230 Vac, 60 Hz, 1.2 Amps File: IM_091-9HP-220-RevB2.indd Rev: B2 Revised

More information

Power Distribution System User s Manual. Model: PDS-100

Power Distribution System User s Manual. Model: PDS-100 Power Distribution System User s Manual Model: PDS-0 Section Page Product Overview... 1 I) General Information... 2 II) Important Safety Information... 2 III) Installation... 3 A) Materials Provided...

More information

INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC MODEL #091-9B-220. INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY

INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC MODEL #091-9B-220. INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY BOOK# 091-9B-220 4-18-2002 INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC AIR COMPRESSOR SYSTEM MODEL #091-9B-220 INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY KUSSMAUL

More information

INSTRUCTION MANUAL ENGINE IDLER MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

INSTRUCTION MANUAL ENGINE IDLER MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. 10-19-96 INSTRUCTION MANUAL ENGINE IDLER MODULE PART OF A HIGH IDLE SYSTEM ENGINE IDLER MODEL #091-84-005 3 YEAR WARRANTY ELECTRONICS CO., INC. 170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796 TEL: in NY 631-567-0314

More information

PUMP PLUS 1200 MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PUMP PLUS 1200 MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL UM LUS 1200 AUTOMATIC SINGLE OUTUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-193-12 INUT: 120 Volt, 60 Hz, 10 Amps OUTUT: 40 Amps File: IM_091-193-12_revH.indd

More information

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER INSTRUCTION MANUAL FILE: 091-165-12 reve Rev: E, page 8 DATE: 7-02-15 AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER MODEL #091-165-12 NOTE : This charger is designed for vehicles with a single battery and negative

More information

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version MD10 Engine Controller Installation and User Manual for the MD10 Engine Controller. Full Version File: MartinMD10rev1.4.doc May 16, 2002 2 READ MANUAL BEFORE INSTALLING UNIT Receipt of shipment and warranty

More information

DMC mA Positioner

DMC mA Positioner DMC-100 4-20mA Positioner TELEPHONE: +1-859-727-7890 TOLL FREE: +1-800-662-9424 FAX: +1-859-727-4070 E-MAIL: DVOGES@INDELAC.COM MROBINSON@INDELAC.COM TCAYWOOD@INDELAC.COM SHIPPING ADDRESS: 6810 POWERLINE

More information

MAXIGARD A2000 SPEED SWITCH. Introduction

MAXIGARD A2000 SPEED SWITCH. Introduction A107-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 MAXIGARD A2000 SPEED SWITCH Introduction The Maxigard A2000 Speed Switch is designed to monitor

More information

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website: BLHV, BLHV-1 High Voltage Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com #L010015 (714) 992-6990 fax: (714)

More information

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction A186-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED Introduction The MAXIGARD A1500

More information

THE SUPER 16 AUTO EJECT

THE SUPER 16 AUTO EJECT INSTALLATION GUIDE AND MANUAL 091-182 SUPER 16 AUTO-EJECT THE SUPER 16 AUTO EJECT AUTOMATIC SHORE LINE DISCONNECT 3 YEAR WARRANTY Assembled and Distributed in Europe by LUDO McGURK TRANSPORT EQUIPMENT

More information

MDCSL V, 30A

MDCSL V, 30A MDCSL100-050301 50V, 30A Sensorless Controller User s Guide A N A H E I M 4985 E. Landon Drive, Anaheim, CA 92807 e-mail: info@anaheimautomation.com A U T O M A T I O N (714) 992-6990 fax: (714) 992-0471

More information

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual Graham TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual Vari Speed S1000 Instruction Manual TABLE OF CONTENTS Introduction 4 Unit Features 5 Operating Conditions 6 Specifications 7 Ratings

More information

A5000GEC-24VDC ZERO SPEED SWITCH

A5000GEC-24VDC ZERO SPEED SWITCH A208-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 A5000GEC-24VDC ZERO SPEED SWITCH Introduction The MAXIGARD A5000GEC-24VDC is a zero speed switch

More information

Generator Start Control Module

Generator Start Control Module Generator Start Control Module Part# GSCM Rev C. Code Version: 5.13 ATKINSON ELECTRONICS, INC. 14 West Vine Street Murray, Utah 84107 Table of Contents Operations... 3 Specifications... 3 GSCM Wiring Diagram...

More information

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz. 1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz. 3. AMMETER/PERCENT OF LOAD: Displays the load on the generator in amps or in percentage.

More information

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2 CONVEYOR COMPONENTS COMPANY Division of Material Control, Inc. 130 Seltzer Road, PO Box 167 Croswell, MI 48422 USA PHONE: (810) 679-4211 TOLL FREE (800) 233-3233 FAX: (810) 679-4510 Email: info@conveyorcomponents.com

More information

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA MDC150-012301 12V, 30A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA BLD75-1 Bilevel Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website:

More information

SUPER AUTO EJECT AUTOMATIC SHORELINE DISCONNECT 3 YEARS WARRANTY. Assembled in the UK by LUDO McGURK TRANSPORT EQUIPMENT LTD WILMSLOW - U.K.

SUPER AUTO EJECT AUTOMATIC SHORELINE DISCONNECT 3 YEARS WARRANTY. Assembled in the UK by LUDO McGURK TRANSPORT EQUIPMENT LTD WILMSLOW - U.K. INSTALLATION GUIDE AND MANUAL SUPER AUTO EJECT AUTOMATIC SHORELINE DISCONNECT 3 YEARS WARRANTY Assembled in the UK by LUDO McGURK TRANSPORT EQUIPMENT LTD WILMSLOW - U.K. A KUSSMAUL ELECTRONICS CO., INC.PRODUCT

More information

DPS32001 and DPS32PS1

DPS32001 and DPS32PS1 DPS32001 and DPS32PS1 Driver Pack User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website: www.anaheimautomation.com

More information

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA MBDC050-024031-120V 110VAC Input Brush DC Controller User s Guide A N A H E I M A U T O M A T I O N 4985 East Landon Drive, Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)

More information

Manual Installation & Operation

Manual Installation & Operation Manual Installation & Operation Model: NCxxLxx 12A or 30A Solid State Solar Charging Regulator and 12A Load Controller. 231 Patent #: 5,642,030 Applies Page 1 Warnings When Installing, connect grounds,

More information

GENERATOR START CONTROL MODULE

GENERATOR START CONTROL MODULE GENERATOR START CONTROL MODULE Operating and Installation Instructions Many automatic control features: Automatic starting, load transfer & shutdown of gas/diesel generators, especially for off-grid uses

More information

DPBHV001, DPZHV002. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

DPBHV001, DPZHV002. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website: DPBHV001, DPZHV002 High Voltage Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)

More information

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator Manufactured by NICE SpA INSTALLATION MANUAL 08/10 CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 3 Applications...... 4 Pre-Installation Checklist... 5

More information

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications An ISO 9001:2015 Registered Company ECO3-601/602 EcoStar III 2009-2019* Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications * In 2017-2018, the ignition switches on Chevy Express

More information

MBD Enhanced Step Motor Driver. User s Guide #L East Orangefair Lane, Anaheim, CA

MBD Enhanced Step Motor Driver. User s Guide #L East Orangefair Lane, Anaheim, CA MBD45021-75 Enhanced Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website:

More information

65E CONTROL SERIES CONTROLS. Instruction Manual. For DC Input Variable Speed Controls. P.0. Box W. 106th Street Zionsville, Indiana 46077

65E CONTROL SERIES CONTROLS. Instruction Manual. For DC Input Variable Speed Controls. P.0. Box W. 106th Street Zionsville, Indiana 46077 65E CONTROL SERIES CONTROLS Instruction Manual For DC Input Variable Speed Controls P.0. Box 10 5000 W. 106th Street Zionsville, Indiana 46077 Phone (317) 873-5211 Fax (317) 873105 www.dartcontrols.com

More information

DPD72001, DPD Unipolar Step Motor Driver. User s Guide E. Landon Drive Anaheim, CA

DPD72001, DPD Unipolar Step Motor Driver. User s Guide E. Landon Drive Anaheim, CA DPD72001, DPD72002 Unipolar Step Motor Driver User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL AUTOMATIC FILTERS, INC. 67 S. LA CIENEGA BLVD. LOS ANGELES, CA 90034 30 839 88 800 336 94 FAX 30 839 6878 www.tekleen.com info@tekleen.com Tekleen GB6 & GB7 USERS MANUAL GB6 & GB7 USERS MANUAL AUTOMATIC

More information

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control Phone 712.722.4135 groschopp.com 420 15th St NE, Sioux Center, IA 51250 Toll-Free 800.829.4135 Email sales@groschopp.com FAX 712.722.1445

More information

INSTALLATION GUIDE Table of Contents

INSTALLATION GUIDE Table of Contents CT-3100 Automatic transmission remote engine starter systems. What s included..2 INSTALLATION GUIDE Table of Contents Door lock toggle mode..... 4 Notice...2 Installation points to remember. 2 Features..2

More information

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity. INSTALLATION, OPERATION and MAINTENANCE MANUAL MODEL SCPF1 15, 25, 40 & 65 AMP SCR POWER CONTROLS UL/cUL FILE NUMBER E151547 CE See last page of manual for CE Declaration of Conformity. AMETEK HDR POWER

More information

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1 OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1 This instruction manual contains important information regarding the installation, operation, and troubleshooting of

More information

Generator Start Control Module

Generator Start Control Module Generator Start Control Module Part# GSCM-mini-o ATKINSON ELECTRONICS, INC. 14 West Vine Street Murray, Utah 84107 Contact cbdsales@atkinsonel.com for the proper hookup diagram. Please include the generator

More information

Generator Start Control Module

Generator Start Control Module Generator Start Control Module Part# GSCM-mini-i ATKINSON ELECTRONICS, INC. 14 West Vine Street Murray, Utah 84107 Contact cbdsales@atkinsonel.com for the proper hookup diagram. Please include the generator

More information

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA MDCKB1-120081 120VAC, 8A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

GENERATOR START CONTROL MODULE

GENERATOR START CONTROL MODULE GENERATOR START CONTROL MODULE Operating and Installation Instructions Many automatic control features: Automatic starting, load transfer & shutdown of gas/diesel generators, especially for off-grid uses

More information

VTC610 Series Voltage Converter. Installation & Operation Manual

VTC610 Series Voltage Converter. Installation & Operation Manual VTC610 Series Voltage Converter Installation & Operation Manual IMPORTANT SAFETY INSTRUCTIONS 1) SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for this voltage

More information

ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller.

ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller. ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller. Full Version File: ES52rev2.63.doc October 24, 2006 2 Thank You For Purchasing This DynaGen Product

More information

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA BLDPN30001 Series 30A Brushless DC Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317) 715B CONTROL SERIES CONTROLS Instruction Manual Line Voltage DC Brushless Motor Control LT715B (IM-715B-0100) P.O. Box 10 5000 W. 106th Street Zionsville, Indiana 46077 Phone (317) 873-5211 Fax (317) 873-1105

More information

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual UniTorq UTQ 1.5 6.4 Quarter-Turn Actuator Installation and Operation Manual Thank you for purchasing our UTQ 1.5-6.0 Electric Actuators Before installation or operation of the actuator carefully review

More information

This document describes:

This document describes: Thank you for purchasing this product from ERM. We appreciate your interest in our unique product line as we try to offer our customers an alternative to today s traditional products. This programmable

More information

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control Phone 712.722.4135 groschopp.com 420 15th St NE, Sioux Center, IA 51250 Toll-Free 800.829.4135 Email sales@groschopp.com FAX 712.722.1445

More information

400W Solar Charger Maximum Power Point Tracker

400W Solar Charger Maximum Power Point Tracker Page 1 of 8 This revolutionary maximum power point tracker solar charger was designed using the technology that won GSL Electronics the prestigious 2008 EDN Innovation award. A simple, compact and low

More information

Installation Instructions for the Lingenfelter Fan and Pump Manual Override Kit

Installation Instructions for the Lingenfelter Fan and Pump Manual Override Kit Installation Instructions for the Lingenfelter Fan and Pump Manual Override Kit PN: L300180000 v1.1 Lingenfelter Performance Engineering 1557 Winchester Road Decatur, IN 46733 (260) 724-2552 (260) 724-8761

More information

TM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060

TM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060 TM4500 Track Mounted Step Motor Driver User s Guide CE Certified and RoHS Compliant A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA MDCKB1-120081-01 110VAC, 8A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR MB-3688 120A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR User Manual Warning and Precautions MB-3688 is built with corrosion resistant material and the main electronic assembly is well sealed inside

More information

SAFTRONICS DF8 PLUS SERIES

SAFTRONICS DF8 PLUS SERIES DF8 PLUS SERIES ¼ to 5 HP Full Wave Regenerative Reversing SCR Speed Controls for DC Motors CAUTION Equipment is at possibly lethal AC line voltage when AC power is connected. Pressing the STOP pushbutton

More information

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC. USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT Galley Power LLC www.galleypower.com Table of Contents Safety Notice... 3 Disclaimer... 3 Safety Instructions... 4 1. Introduction... 5 1.1 Features and

More information

MBDC V, 10A Brush Controller. User s Guide East Landon Drive, Anaheim, CA

MBDC V, 10A Brush Controller. User s Guide East Landon Drive, Anaheim, CA MBDC050-050101 50V, 10A Brush Controller User s Guide A N A H E I M A U T O M A T I O N 4985 East Landon Drive, Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471 website:

More information

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02 SELECT DIAGNOSTIC GUIDE INST028 Doc 3.02 CONTENTS General Information...2 Select Call-Outs...3 Wire Diagram and Legend...4 Diagnostics...6 Excessive Voltage Drop Diagnostics...6 Static Diagnostics...7

More information

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com

More information

PRO REMOTE Series CAPACITANCE PROBE

PRO REMOTE Series CAPACITANCE PROBE Price $5.00 PRO REMOTE Series CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS GENERAL SPECIFICATIONS...3 1.0 INTRODUCTION...4 2.0 APPLICATIONS...4

More information

APOLLO Gate Operators, Inc.

APOLLO Gate Operators, Inc. APOLLO Gate Operators, Inc. Model BA12 12 VOLT DC BARRIER ARM OPERATOR INSTALLATION MANUAL 0707 CONTENTS IMPORTANT SAFETY INSTRUCTIONS... 3 Applications... 4 Pre-Installation Checklist... 5 Operator Installation...

More information

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT!

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT! Limited Warranty Statement GNU COMMANDO LINE WARRANTY STATEMENT GNU warrants this product to be free from defects in material and workmanship for a period of one (1) year from the date of sale to the original

More information

730 CONTROL SERIES. Instruction Manual CONTROLS. Low Voltage DC Brushless Control. Phone (317) Fax (317)

730 CONTROL SERIES. Instruction Manual CONTROLS. Low Voltage DC Brushless Control. Phone (317) Fax (317) 730 CONTROL SERIES CONTROLS Instruction Manual Low Voltage DC Brushless Control P.O. Box 10 5000 W. 106th Street Zionsville, Indiana 46077 Phone (317) 873-5211 Fax (317) 873-1105 www.dartcontrols.com LT117

More information

INSTALLATION & OWNER'S MANUAL

INSTALLATION & OWNER'S MANUAL INSTALLATION & OWNER'S MANUAL THE EAGLE POWER I BATTERY BACK UP PHONE (818) 764-6690 / TOLL FREE (800) 708-8848 PRE INSTALLATION INSTRUCTIONS BEFORE PROCEEDING WITH INSTALLATION READ THIS MANUAL THOROUGHLY

More information