PF/PFQ. High amperage plugs & receptacles. Features and Ratings p. 128 PF/PFQ A p. 129 PF/PFQ Lugs p. 131 Spare parts p. 133 Dimensions p.
|
|
- Valerie Richards
- 6 years ago
- Views:
Transcription
1 Features and Ratings p. 128 PF/PFQ A p. 129 PF/PFQ Lugs p. 131 Spare parts p. 133 Dimensions p. 134 High amperage plugs & receptacles Watch the PF video and other product videos at meltric.com/video PF and PFQ Series plugs and receptacles are engineered for use in high amperage applications where routine plug insertion and high reliability are required. They are ideal for power supply applications in mining, petroleum platform, ship to shore, power generation system, shipyard and other similar harsh environments. Main Advantages u Durable in harsh environments u Safety features provide maximum protection u Easy plug insertion and removal PFQ300 devices are differentiated from similarly rated PF300 devices in their smaller size, lighter weight and additional pilot contacts. 127
2 Product Features Operating Instructions Auxiliary Pilot Contacts Provided for use with control circuits. They close after and open before the phase contacts. Mechanical Locking System Ensures safety and watertightness. Mechanical lock secures the inlet to the receptacle and engages the pilot contacts. PF devices are preferred for the ease of operation relative to pin and sleeve devices. 1 2 Casing Epoxy/powder coated aluminum material offers great resistance to harsh environments. Silver Pressure Contacts Silver material and self-cleaning action provides maximum conductivity and performance in dirty and corrosive conditions. Safety Shutter Protects recessed female contacts and inhibits user access to live parts. Insert the plug into the receptacle this is done with little resistance relative to competitive devices. General Ratings Amperage Voltage + Frequency Environmental 300 to 600A 1000 VAC*, 1000 VDC Max Hz IP66/IP67 Listings Category UL CSA Plugs and Receptacles UL 1682* C22.2 No * * Listings only apply to 300A and 400A devices at or less. Twist plug approximately 30 clockwise to engage the phase contacts and make unit watertight. 3 HIGH AMPACITY Temperature min -40 F/max 140 F * 600 VAC max for PFQ devices. + UL listings do not apply above 600 VAC and 250 VDC. Highlighted Feature TO LOAD A B C PF/PFQ INLET/PLUG MALE PILOT CONTACTS JUMPER 2 PILOT CONTACTS TO COMPLETE CIRCUIT NOTE: ROTATE RECEPTACLE LOCKING CAM TO ENGAGE PILOTS PF/PFQ RECEPTACLE/ CONNECTOR FEMALE PILOT CONTACTS PHASE PILOT CIRCUIT Line diagram of typical PF pilot control circuit For multiple devices in a parallel circuit, contact factory for example control circuit diagrams. A B C Pilot Contacts CONTACTOR OR BREAKER WITH UNDER VOLTAGE TRIP COIL LINE PILOT CIRCUIT POWER SWITCH ETC. Category PF PFQ # Contacts 4 8 Pilot Amperage 10A standard duty 240VAC Interlocking Type Mechanical Mechanical Terminal Type Screw Solder/crimp Notes: The mechanical locking of the plug to the receptacle via the rotation of a cam, closes the pilot contacts. Failure to use a pilot/relay system can create an electrical shock hazard. 4 Turning the mechanical lock secures the inlet to the receptacle and engages the pilot contacts which energize the circuit. 5 To disconnect, turn mechanical lock to disengage pilot contacts and de-energize the circuit. Twist plug 30 counterclockwise to disengage the phase contacts, withdraw plug. 128
3 PF/PFQ 300A - 600A High Ampacity Plugs & Receptacles UL/CSA Ratings Max Amperage & Voltage PF = 600A, 1000 VAC*, 250 VDC PFQ = 300A, 600 VAC, 250 VDC Current Interruption Capability Not for current interrupting Temperature Range Min -40 F/Max 140 F See pg 234 for temps below -15 F. Wiring Capacity PFQ = 2 AWG to 600 MCM PF = 2 AWG to 600 MCM Receptacle/Cap (female) 300A Don t forget to add installation accessories to your order PFQ shown Inlet/Cap (male) 300A PFQ shown North American UL/CSA Configurations # # Voltage Polarity Voltage Polarity PFQ300** PF300 PFQ300** PF300 Applicable Standards UL 1682*, CSA 182.1* * Listings apply only to 300A & 400A devices at or less 1P+N+G P+N+G P+G P+N+G P+N+G P+N+G P+G P+N+G P+G P+G PF/PFQ devices are not intended for connection or disconnection under load. To prevent live making or breaking electrical interlocking is required. 3P+N+G P+G P+N+G P+G P+N+G P+G P+N+G P+G P+N+G P+N+G Main Options Receptacle Recept # - 48 with no cap ** PFQ300 devices are differentiated from similarly rated PF300 devices in their smaller size, lighter weight and different pilot contacts. For international configurations and ratings (IEC,CE) visit meltric.com/international-catalog or contact customer service at Receptacle/Cap (female) 400A/600A Inlet/Cap (male) 400A/600A Receptacle with Recept # lockout hole Inlet with Inlet # - 48 no cap Inlet with Inlet # lockout hole Notes: Metal caps are provided as standard with male and female devices. Heat shrink wrap is provided with each inlet and receptacle to provide insulation between terminals. Lugs are not included. The PF and PFQ contacts utilize bolt-on lug type wire terminals, which require a compression lug with a 9/16 or 5/8 hole. The angled handle requires straight lugs; the straight handle requires 90 lugs. 129 # # Voltage Polarity Voltage Polarity PF400 PF600 PF400 PF600 1P+N+G P+N+G P+G P+N+G P+G P+N+G P+G P+N+G P+G P+N+G For applications above 400A, please consult factory regarding NEC recommended conductor sizing. North American UL/CSA Configurations 1P+N+G P+N+G P+G P+N+G P+G P+N+G P+G P+N+G P+G P+N+G For international configurations and ratings (IEC,CE) visit meltric.com/international-catalog or contact customer service at
4 Installation Accessories PF/PFQ Handles PF shown Standard Clamp shown Inlet/Receptacle Metal Straight Metal 90 Angled Handle Handle PFQ A013-XXX 47-3A913-XXX PF A013-XXX 49-3A913-XXX PF A013-XXX 49-4A913-XXX PF A013-XXX 49-6A913-XXX Junction Boxes Standard Clamp + XXX (Suffix #) Cable Range or XXX (Suffix #) Notes: NPT Adapter NPT -N NPT -N NPT -N NPT For available cord grips, see pgs Accessory Spotlight NPT Adapter Inlet/Receptacle Hub Metal Junction s Box PFQ300 See table MB40PFQ-XX PF300 See table MB40-XX PF400 See table MB40-XX PF600 See table MB40-XX Hub s XX (Suffix #) Fitting NPT NPT NPT NPT NPT NPT Adapter Straight or Angled Handle Cord Grip w/mesh (not provided) A NPT adapter accessory allows the user to connect a third party cord grip to the PF/PFQ handle. Miscellaneous Accessories PF shown Highlighted Feature Bolt-on Lug (not included) Angled Lug Straight Lug HIGH AMPACITY Inlet/Receptacle Inlet Receptacle Metal Cap Metal Cap PFQ A A925 PF A A925 PF A A925 PF A A925 Weights PF PFQ Inlet 15 lbs 9 lbs Receptacle 25 lbs 12 lbs Angled Handle 15 lbs 12 lbs Straight Handle 10 lbs 10 lbs Junction Box 45 lbs 45 lbs Cap 3 lbs 3 lbs Order Example A typical order should include an inlet part number, a receptacle part number AND the matching handles, angles or other required accessories. (Lugs are not included.) Male Inlet with Handle (Plug) A The PF and PFQ contacts utilize bolt-on lug type wire terminals, which require a compression lug with a 9/16 or 5/8 hole. The angled handle requires straight lugs; the straight handle requires 90 lugs. Lugs are not included. See following page. Female Receptacle w/junction Box MB
5 PF/PFQ 300A - 600A High Ampacity Plugs & Receptacles Straight Barrel Lugs MELTRIC recommends using lugs with tangs that do not exceed 1 3/4. Lugs are not included with PF/PFQ devices - order separately PFLUG4 PFLUG3 PFLUG2 PFLUG1 PFLUG10 PFLUG20 PFLUG30 PFLUG40 PFLUG250 PFLUG300 PFLUG350 PFLUG400 PFLUG500 PFLUG600 PFLUG650 4 AWG 3 AWG 2 AWG 1 AWG 1/0 AWG 2/0 AWG 3/0 AWG 4/0 AWG 250kcmil 300kcmil 350kcmil 400kcmil 500kcmil 600kcmil 650kcmil Application Note Installation Accessory: Angled Handle Straight Barrel Lugs are utilized on PF/ PFQ devices along with angled handles. Typical wiring of a PF male inlet for angled handle applications. Note: Apply heat shrink over lugs at terminals (supplied but not shown). 131
6 90 Bent Lugs MELTRIC recommends using lugs with tangs that do not exceed 1 3/4. Lugs are not included with PF/PFQ devices - order separately Application Note PFLUG AWG PFLUG3-90 PFLUG AWG 2 AWG Installation Accessory: Straight Handle PFLUG AWG PFLUG /0 AWG PFLUG /0 AWG PFLUG /0 AWG PFLUG /0 AWG PFLUG kcmil PFLUG kcmil PFLUG kcmil PFLUG PFLUG PFLUG kcmil 500kcmil 600kcmil 90 Bent Lugs are utilized on PF/PFQ devices along with straight handles. HIGH AMPACITY Typical wiring of a PF male inlet for straight handle applications. Note: Apply heat shrink over lugs at terminals (supplied but not shown). 132
PF/PFQ. High amperage plugs & receptacles. Features and Ratings p. 132 PF/PFQ A p. 133 PF/PFQ Lugs p. 135 Spare parts p. 137 Dimensions p.
Features and Ratings p. 132 PF/PFQ 300-600A p. 133 PF/PFQ Lugs p. 135 Spare parts p. 137 Dimensions p. 138 High amperage plugs & receptacles PF and PFQ Series plugs and receptacles are engineered for use
More informationNFPA 70E 68! & CSA Z462
DB Switch-Rated plug and receptacle Main Advantages u Switch & Hp rated u 100 ka short circuit rated* u IP67 environmental ratings u Up to 4 auxiliary contacts u Durable metal construction * See note under
More informationSwitch rated plugs and receptacles with nema 4X protection
DSn Features and Ratings p. 24 DSN20 p. 25 DSN30 p. 27 DSN60 p. 29 Spare parts p. 31 Dimensions p. 33 23 Switch rated plugs and receptacles with nema 4X protection DSN Series products are switch and hp
More informationRobust construction and high amperage capabilities
DR Features and Ratings p. 94 DR30 p. 95 DR50 p. 97 DR100 p. 99 DR150 p. 101 DR 250 p. 103 DR400 p. 105 Spare parts p. 107 Dimensions p. 109 Robust construction and high amperage capabilities DR series
More informationDSN. Switch-rated plug and receptacle with Type 4X protection
DSN Features and Ratings p. 24 DSN20 p. 25 DSN30 p. 27 DSN60 p. 29 DSN150 p. 31 Spare parts p. 33 Dimensions p. 35 Switch-rated plug and receptacle with Type 4X protection DSN Series products are switch
More informationSwitch rated plugs and receptacles
DS Features and Ratings p. 36 DS20 p. 37 DS30 p. 39 DS60 p. 41 DS100C p. 43 DS100 p. 45 DS200 p. 47 Spare parts p. 49 Dimensions p. 51 35 Switch rated plugs and receptacles DS Series Decontactors provide
More informationRobust construction and high amperage capabilities
DR Features and Ratings p. 130 DR30 p. 131 DR50 p. 133 DR100 p. 135 DR150 p. 137 DR 250 p. 139 Spare parts p. 141 Dimensions p. 143 Robust construction and high amperage capabilities 129 DR series plugs
More informationDS Switch-Rated. plug and receptacle. Main Advantages. DS100 p. 48 DS200 p. 50 Spare parts p. 52 Dimensions p. 54
DS SwitchRated plug and receptacle Main Advantages u Switch & Hp rated (AC only) u 65 ka to 100 ka short circuit rated* u Up to 6 auxiliary contacts u Amperage ratings up to 200A u Metal or Poly construction
More informationHEAVY-DUTY PLUGS & SOCKETS
HEAVY-DUTY PLUGS & SOCKETS 315 A/400 A/500 A/600 A Up to 600 A/1 000 V Automatic IP66/IP67 water-and dust-tight Mechanical and electrical interlocking Up to 6 auxiliary and 2 pilot contacts Marine aluminum
More information315 A / 400 A / 500 A / 600 A
PF HEAVY-DUTY PLUGS & SOCKETS 315 A / 400 A / 500 A / 600 A UP TO 600 A / 1000 V AUTOMATIC WATER- AND DUST-TIGHT MECHANICAL AND ELECTRICAL INTERLOCKING UP TO 6 AUXILIARY AND 2 PILOT CONTACTS Big equipment
More informationINDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com
More informationWastewater Solutions
Wastewater Solutions Featuring Meltric s Switch-Rated Plugs, Receptacles and Electrical Connectors meltric.com A company of MARECHAL ELECTRIC GROUP Meltric DECONTACTOR TM Series Plugs & Receptacles Decontactors
More informationWastewater Solutions. DECONTACTOR TM Series. Featuring Meltric s. Switch Rated Plugs, Receptacles and Electrical Connectors
Wastewater Solutions Featuring Meltric s DECONTACTOR TM Series Switch Rated Plugs, Receptacles and Electrical Connectors Meltric DECONTACTOR TM Series Plugs & Receptacles Decontactors are a combination
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationNATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number
More informationTaxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description
More informationARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 ARL2042 Receptacle Cooper Crouse-Hinds Catalog Number Manufacturer Description Weight per unit Product Category Descriptions
More informationBenefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine
eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use
More informationInstruction Sheet for Powertite Plug, Connector and Receptacle
330087 Instruction Sheet for Powertite Plug, Connector and Receptacle Powertite 200 Amp Pin & Sleeve Receptacles, Cable Connectors and Plugs: NEMA 4X. 600 Volt AC, 250 Volt DC. Wire Recess Diameter:.687.
More informationPIN & SLEEVE DEVICES
PIN & SLEEVE DEVICES line of industrial plugs and sockets are manufactured by ABL Sursum, a company well known in Europe for its quality electrical products. This major manufacturer combines the elements
More informationArktite Heavy Duty Circuit Breaking Plugs and Connectors
Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
P Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors, cellular relay stations, and similar apparatus. Ideal for use
More informationACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number ACP1034CD Manufacturer Appleton/Oz Gedney
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas
1P Arktite Heavy Duty Circuit Breaking s and s Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically operated
More informationDuraGard Waterproof Connections
In this section... DuraGard Waterproof Connections DuraGard Overview...54 57 20 Amp...58 59 30 Amp...60 61 50 Amp...62 63 60 Amp...64 Accessories...65 66 Safety Interlocks...67 Dimensions...68 Engineering
More informationACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC) Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
1P Arktite Heavy Duty Circuit Breaking s and Receptacles Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically
More informationReceptacles & Wall Boxes
Receptacles & Wall Boxes with Integral Circuit Protection MELTRIC s receptacle/wall box combinations with integral circuit protection combine the safety of a MELTRIC DSN series switch-rated receptacle
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically
More informationDuraGard Waterproof Connections
In this section... DuraGard Waterproof Connections DuraGard Overview...54 57 20 Amp...58 59 30 Amp...60 61 50 Amp...62 63 60 Amp...64 Accessories...65 66 Safety Interlocks...67 Dimensions...68 Engineering
More informationQuick Connection Panel (QCP) Installation Guide
Quick Connection Panel (QCP) Installation Guide DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read this document first. The installer is responsible for compliance with National Electrical
More informationCam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.
Cam-Lok Single Pole Connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok Single Pole Connectivity Cam-Lok connectors are the industry standard Cam-Lok
More informationAPJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 APJ10487 100 Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac Cooper Crouse-Hinds Catalog Number Manufacturer Description
More information20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!
COMPACT AND WATERTIGHT DECONTACTOR 20 A / 32 A / 63 A AUTOMATIC ip66/ip67 water- and dust-tight sealing AC-22 and ac-23 breaking capacity Impact-resistant GRP casing With sizes from 20 to 63 A, DSN decontactors
More informationWashdown Industrial/Light Marine UniGuard
Safety, Performance and Durability in a Snap! Beverage Plants Construction Sites Food Processing Marine and Shipboard Pulp and Paper Mills Chemical Plants Extensive Product Family Safe and reliable, portable
More informationEPOXY POWDER COATED COPPER FREE ALUMINUM
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AJA510 Alum MTG Unilet Appleton/Oz Gedney Catalog Number Manufacturer Description Weight per unit Product Category Features
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically operated devices
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically operated devices
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically
More informationPlugs, Receptacles & Connectors
Plgs, Receptacles & Connectors for the Aviation Indstry Featring: Switch-Rated Plgs & Receptacles with DECONTACTOR Technology Switch-Rated High Amp Mltipin meltric.com A company of MARECHAL ELECTRIC GROUP
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Applications: Arktite circuit breaking plugs and receptacles are used: To supply power to portable electrically
More informationArktite Plugs, Receptacles, and Connectors
Arktite Plugs, Receptacles, and Connectors Arktite Plugs, Receptacles, and Connectors THE COOPER CROUSE-HINDS STANDARD Put a century of standard-setting experience to work for you. For more than a century,
More informationOne piece neoprene protective sleeve seals wiring area from dirt, grit and moisture.
Quik-Loc Connectors 600 Volt Standard Applications: Drills Shuttle cars Conveyors Power distribution Slusher hoists Motors Heavy equipment Ship-to-shore power Features: Corrosion-resistant - molded neoprene
More informationElectrical Wiring Practices
Chapter 2 Electrical Wiring Practices and Diagrams MElec-Ch2-1 Overview Safety Standards Wiring Considerations Wire Terminations Coaxial Cable Wiring Installations Wiring Diagrams MElec-Ch2-2 Safety Lethal
More informationCam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions.
Plugs & receptacles Cam-Lok single pole connectivity Cam-Lok Single pole connectivity The industry standard for reliable service under the most severe operating conditions. Cam-Lok single pole connectivity
More informationIEC 309 Plugs, Connectors, Receptacles, and Inlets
IEC 309 Plugs, Connectors, Receptacles, and Inlets Applications: Where complete protection against dirt, dust, and water jets is required In damp or corrosive locations In areas prone to vibration, hard
More informationPlugs and Receptacles: Hazardous Location
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Plugs and Receptacles Plugs and Receptacles: Hazardous Location Applications Locations where receptacles are used with stationary or portable
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors,
More informationU-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof
U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof Class I, Groups C, D Class I, Division 2, Group B Class I, Zone 1, Group IIB Class I, Zone 2, Group IIB +
More informationPlugs & Receptacles. PowerMate. drilling pin and sleeve connectors
s & Receptacles PowerMate drilling pin and sleeve connectors Safe. Reliable. Fast. Connections The ideal rig power connection solution Longer product life Reduced maintenance Enhanced safety Easy to install
More informationOTEC Transfer switch open transition
Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors,
More informationStandard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat
U-Line Factory Sealed 15 and 20 Amp Plugs and Receptacles V Applications Locations where receptacles are used with stationary or portable electrically operated devices such as: Lighting systems Conveyors
More informationMOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY
MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS hyconelec.co.za MARECHAL TECHNOLOGY SAFE AND RELIABLE ELECTRICAL CONNECTIONS FOR YOUR MOTORS. MARECHAL ELECTRIC offers a range of
More informationSample Installation: Fixed Power Source (Wall) to Remote/Portable Location
Industrial interlocked receptacles are available in 30 through 400. Switched receptacles have mechanical linkages for added safety. Safety features include: Plugs cannot be inserted unless power is safely
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationPowertite Series Pin and Sleeve Plugs, Connectors and Receptacles
Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles Applications Designed to supply power to portable or fixed electrical equipment such as motor generator units, welders, pumps, compressors,
More informationSolar Combiner Solutions
Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from
More informationReceptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Applications
More informationAdvAntAge SerieS Switch-rAted iec Pin And Sleeve
Wiring Device-Kellems AdvAntAge SerieS Switch-rAted iec Pin And Sleeve now AvAilAble in 30 & 60 AmP Highest Performing IEC Pin and Sleeve Connections for the Most Demanding Environments Hubbell s Pin and
More informationSECTION SECTION. EATON 2014 Arrow Hart Buyers Guide
F SECTION SECTION 1 EATON 2014 Arrow Hart Buyers Guide FSECTION Cam-lok Single Pole Connectivity Table of contents Product selector guide F-3 NEMA rating system F-4 F-series F-5 E1010 F-6 E1012 F-7 F-series
More information20A & 30A IEC 309 Watertight pin & sleeve devices
AH430R7W AH430C7W IP69K certified AH430P7W Product Description - North American 20A & 30A; 2-pole, 3-wire grounding; 3-pole, 4-wire grounding; 4-pole, 5-wire grounding Pin & sleeve plugs features & benefits
More information22AF 40AF AF 150AF 225AF 400AF 800AF
Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug
More informationSpring-loaded cover seats against neoprene gasket.
U-Line Factory Sealed 20 Amp Plugs and Receptacles Dead-Front Safety Construction. Choice of Aluminum or Thermoplastic Polyester Plug. Class I, Division 1 and 2 Groups B, C, D NEMA 3, 3R, 7BCD, 9FG Plugs
More informationD4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.
Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationHubbell Marine Isolation Transformers 15 kva and 25 kva Models
Shore Power System 15 kva and 25 kva Models Protects Sensitive Equipment on Board Virtually Eliminates Potential for In-Water Stray Current Can be wired per ABYC E-11 for either a Polarization or Isolation
More informationI-BFV.KIT Butterfly Valve Gear Operator Replacement
SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before
More informationHP20 Series. Utilizes a Small #20 Size Shell Accommodates Up to 646 MCM Cable Patents Pending
HP20 Series Utilizes a Small #20 Size Shell Accommodates Up to 646 MCM Cable Patents Pending RigPower s mission is to create new industry standards in industrial electrical connectors by combining appropriate
More informationInstalling Power Components
This chapter provides instructions on how to install and reinstall power components in the Cisco NCS 4016 chassis. It also covers connecting and disconnecting power and powering on the chassis. The Cisco
More informationSECTION SECTION SECTION EATON 2016 Arrow Hart Buyers Guide
F SECTION SECTION SECTION 1 EATON 2016 Arrow Hart Buyers Guide www.arrowhart.com /arrowhart FSECTION Cam-Lok Single Pole Connectivity Table of contents Product selector guide F-3 NEMA rating system F-4
More informationRussellstoll Pin & Sleeve Power Connectors
In this section... Russellstoll Pin & Sleeve Power Connectors Russellstoll Pin & Sleeve Power Connectors Overview/Application Guide... H-294 H-295 MaxGard Interconnection Systems... H-296 H-343 J-Line
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable
More informationPowerPact Circuit Breakers for Control Panel Disconnects Class 0611
Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical
More informationControl & Power, Inc
Way/ 2 and 3 Position Four ported valves are generally used to operate double-acting cylinders or actuators. They have four or five pipe connections, commonly called ports: One pressure inlet. Two cylinder
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationReceptacles & Wall Boxes with Integral Circuit Protection
product description New Product Announcement Issue date: 25 January 2012 Receptacles & Wall Boxes with Integral Circuit Protection Meltric s receptacle/wall box combinations with integral circuit protection
More informationPRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:
Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD
More informationEPIC. Pin & Sleeve Connectors PIN & SLEEVE CONNECTORS
PIN & SLEEVE CONNECTORS Reference Pin & Sleeve Overview 461 Pin & Sleeve Products Overview 462 CEE series, MULTIMAX series, ULYSSE series, ALUPRES series Pin & Sleeve Construction 464 MULTIMAX Installation
More informationTransfer switch OTEC and OTECSE open transition
Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They
More informationJOSLYN CLARK VACUUM CONTACTORS
COLTERLEC ELECTRICAL ENGINEERING PRODUCTS SECTION JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS 339 TM CONTENTS Joslyn Clark - New 300Amp, 1140 Volt Heavy Duty Mining Vacuum
More informationSWITCH-RATED = + Plugs & Receptacles THE MAIN DIFFERENCES. DECONTACTOR TM Technology. Switch and Hp Ratings. Short Circuit Ratings
SWITCH-RATED Plgs & Receptacles THE MAIN DIFFERENCES DECONTACTOR TM Technology Like most MELTRIC prodcts, Switch-Rated plgs and receptacles featre (see pgs 6-8) Spring-loaded btt contacts Silver-nickel
More informationUser s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual
User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationUser s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual
User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH
More informationThe Best Flexible Wire Replacement with ERIFLEX FLEXIBAR STANDARD and ERIFLEX FLEXIBAR SUMMUM
ERIFLEX FLEXIBAR The Best Flexible Wire Replacement with ERIFLEX FLEXIBAR STANDARD and ERIFLEX FLEXIBAR SUMMUM connections are made by punching directly through the laminates. No lugs to purchase, installation
More informationD2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in
More information3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...
Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp
More informationPORTS, MARINAS, SHIPYARDS & VESSELS
PORTS, MARINAS, SHIPYARDS & VESSELS INDUSTRIAL PLUGS & SOCKET-OUTLETS SAFE AND RELIABLE ELECTRICAL CONNECTIONS IDEALLY SUITED TO PORTS, MARINAS, SHIPYARDS & VESSELS MARECHAL ELECTRIC offers a range of
More informationReceptacles & Wall Boxes with Integral Circuit Protection
& Wall Boxes with Integral Circuit Protection MELTRIC s receptacle/wall box combinations with integral circuit protection combine the safety of a MELTRIC DSN series switch-rated receptacle with the convenience
More informationMAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators
MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return
More informationNumber Tube I.P.S. Rod Size or O.D. Range Cable H J W
TYPE GAR D-28 FENCE POST GROUNDING CONNECTOR For Parallel or 90 Copper Cable Connection To Rod or Pipe with the Same Connector High copper alloy ground connector for joining a range of cable, parallel
More informationPART A General Conductor Requirements
PART A General Conductor Requirements 6.1 Conductor Insulation Property Table 310.13 of the NEC provides information on conductor properties such as permitted use, maximum operating temperature, and other