1 Important Information TPN 3 Phase Extension Boxes This unit must be installed by a qualified competent person in compliance with current requirements for Electrical Installations (IEE Wiring regulations Seventeenth Edition: BS7671).! Ensure that all power supplying this equipment is switched OFF before working on or inside the unit.! Confirm the power is off with an appropriately rated volt-sensing device.! Make sure all devices, covers and doors are replaced and secured before switching the power supply back on to the unit.! Remove the gland plates prior to slotting or cutting for cable entries to avoid ingress of swarf & other debris.! The user guide must be available for future reference after installation and testing. Failure to follow these instructions could result in serious injury or death Models Available: TPNEB Empty Expansion Box TPNA16W 16 Way Type A Modular Service Box TPNMM Multi-Function Meter Box All models can be mounted to the top or the bottom of a TPN distribution board although as standard the TPNMM and the TPNEB come ready to mount to the underside and the TPNA16W to the top of the TPN distribution board You Will Need: n Pozidrive PZ2 n Long Reach Pozidrive n Hammer n Adjustable Screwdriver Dimensions n Hole Punch/Jigsaw For More Information sales@europacomponents.com Page 1 of 2 EDS
2 Quality Components at Competitive Prices Fitting Instructions: n First mount and screw the TPN distribution board to the wall, leaving enough room below or above to site the enclosure, as per the instructions that come with the TPN three phase board. n Remove the inner mounting plate of the extension box and leave to one side. n Remove the gland plate, top or bottom depending where the extension box is to be sited, and screw the box to the main board using the 5 Pozidrive screws supplied. The wall holes can now be marked up ready for drilling. n When the extension box is securely fixed to the wall the gland plate that was removed form the TPN main board can now be fit to the bottom of the extension box using the existing Pozidrive screws. The gland plate should be drilled or punched to suit cable entries before fitting, making sure to protect the assembly from swarf and dust. TPNEB TPN16WAY TPNMM Additional Instructions For The Meter Panel TPNMM: n When removing the lid take care to remove the cable plugs from the rear of the meter ensuring that a note is made of which way they are needed to be when re-assembling. Safely store the front panel in a safe place taking care not damage the front of the meter. Remove the earth strap from the case and remove the assembled back plate so that the TPNMM can be secured to the distribution board and wall as per the instructions above. n The main phase cables have to pass through each current transformer (one phase per transformer) before being terminated into the TPN distribution panel, the neutral is wired directly to the neutral connection in the TPN board. n A three phase and neutral control voltage is required, which must be wired to the 10 x 38 fuse holder fitted with 1 amp fuses (Europa part number 16011). Carefully fit the plugs on to the meter checking that all connections are tight and screw the lid on. n The meter will already have been set up to function with the TPN three phase board. Further meter instructions can be found separately. For More Information sales@europacomponents.com Page 2 of 2 EDS
3 Technical Data: TPNMM Three Phase Board Meter Instructions: The meter has already been programmed and is ready to use, but should the meter need to be re-programmed in order to add other features then the following process should be followed. Before a setting can be changed the meter has to be entered into programme mode. Display Meaning Display Meaning Code pur Code Input chag Change Code ser clt.e Energy Clearance disp Display -Sn- Instrument Address Signal Input Communication n.8.1 Data Bite 8, Stop Bite 1, No. Check n33 3 Wire 3 Phase E.8.1 Data Bite 8, Stop Bite 1, Even Parity n34 3 Wire 4 Phase o.8.1 Data Bite 8, Stop Bite 1, Odd Parity ner Network Baud Rate -pr- Voltage Ratio -Cr- Current Ratio Data Format F Frequency EPt Positive Active Power E9t Positive Reactive Power To Enable Changes To Meter Follow This Programming Sequence: SET Display Line At Start Up: This chooses what is displayed when the meter is first switched on. As default it is the single phase voltage. SEr SEr disp SEr disp 0101 Default Display ting 1-7: 0001 = Volts 0003 = Amps 0002 = 3 Phase Volts 0004 = Kw 0005 = Frequency 0006 = Ept 0007 = Eqt Press return twice. The first digit of the bottom box will be flashing. Use the side arrow to move to next digit. Use up arrow to change digit in sequence. Enter Press return twice. (only) Display should now read code in top line. Lines two and three should be blank. Clear Energy Display (Reset): SEr SEr clre SEr clre Clears display. Press set button three times, energy will be reset to zero. Page 1 of 2 EDS
4 Technical Data: TPNMM Voltage and Current Transformer Ratios: SEr ner ner n3.3 = 3 Wire 3 Phase n3.4 = 3 Wire 4 Phase - Factory setting n3.4 Or 3.3 Via the up arrow. Press return twice. -Pr- -Pr- Voltage Ratio Factory setting 0001 For 3 Phase Up To 460V Network ting: -Cr- -Cr Current Transformer 150A = 0030 Current Transformer 200A = 0040 Press return twice Current Ratio Number of meters = 0001 SEr -Sn- -Sn o.8.1 n.8.1 E.8.1 Page 2 of 2 EDS
5 Page 1 of 1 EDS Technical Data: Wiring Schematic TPNMM
Dycon D2430 EN54-4 Fire Alarm Power Supply Series
Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product
More informationINFRESCO-S-4kW X20034 Issue: 7
INFRESCO-S-4kW X20034 Issue: 7 User Manual Date: 17/01/17 Page: 1 of 7 KEY FEATURES Extends lamp Life. Ideal for controlling up to 2 x 2kW lamps. Soft-start/zero-voltage switch-off. Low-cost. Easy to install.
More informationAE012 Enclosure for E5x Series Energy Meters With Swing Panel Kit Product Overview
RoHS Compliant Pictured with the E5x meter installed. E5x meter and enclosure are purchased separately. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationInstruction Bulletin. Jockey Pump Controller
Instruction Bulletin Jockey Pump Controller Installation Start Up Service This instruction bulletin is a guide for personnel involved with maintenance, engineering and approval of Fire Pump equipment and
More informationINFRESCO 2KW VARIABLE CONTROLLER Issue 3
X20018 INFRESCO 2KW VARIABLE CONTROLLER Issue 3 infresco User Manual Date 19/08/14 Page 1 of 6 KEY FEATURES Soft Start up to 30% extended life of Lamp Variable Control Ability to find comfort level Simple
More informationProduct Overview. Product Identification. Amps One CT Two CTs Three CTs
AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationX20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES
X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16 Page 1 of 9 KEY FEATURES Energy saving:- o Only provides heat when people are present. Extends lamp life. Temperature sensor:- o Lamps inhibited
More informationHE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual
HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual Page 1 of 10 CONTENTS 1. GENERAL...2 2. POWER REQUIREMENTS...2 2.1 HE-PSU(4.0) Input/Output Electrical Ratings...2
More informationQuick Start Guide TS 910
Quick Start Guide TS 910 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer is responsible
More informationEnclosure for AMP1 Series Energy Meters with Swing Panel Kit
GE Industrial Solutions DET-809 Installation Instructions AMP1N4 Enclosure for AMP1 Series Energy Meters with Swing Panel Kit Safety FCC PART 15 INFORMATION NOTE: This equipment has been tested by the
More informationDiesel Engine Shutdown System
Diesel Engine Shutdown System Models CSX-300, 310 CSX-301, 311 Typical applications Marine engine safety Petrochemical industry safety Vacuum trucks Cranes - both engines Land drilling rigs Offshore equipment
More informationLED Downlight Ceiling Fixtures
ED Downlight Ceiling Fixtures Every attempt has been made to ensure that this documentation is as accurate and up-to-date as possible. However, Vertical Express assumes no liability for consequences, directly
More informationQuick Start Guide TS 910 & TS 920
Quick Start Guide TS 910 & TS 920 DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationGuidance to Installers of Viridian EV Charging Stations
Guidance to Installers of Viridian EV Charging Stations Iss 6 - Jul 2016 Page 2 of 9 This guide is intended to instruct in the proper installation of a Viridian EV Charging Station. Please note that when
More informationDycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD
Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain
More informationPowerLogic High Density Metering System 4-Meter Enclosure Installation Guide
PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment
More informationINSTALLATION & MAINTENANCE MANUAL HBL
INSTALLATI & MAINTENANCE MANUAL HBL series 230V 50Hz IP 65 122 1 GENERAL INSTRUCTIS These instructions should be read carefully and retained after installation by the end user for future reference and
More informationADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW
ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationInstallation Guide Rollerdor RD55 Econ Roller Garage Door
Installation Guide Rollerdor RD55 Econ Roller Garage Door 1 Finished door Rollerdor RD55 Econ Roller Garage Door CHECKLIST & COMPONENTS EQUIPMENT REQUIRED 2 x Step ladders or hop ups Spirit level Tape
More informationTable of Contents General Information Specifications Dimensions Programming Instructions Installation Parts List Input Devices
b Table of Contents General Information 1 Features...1 Specifications 1 Visi-Tach Model Number Description...2 Dimensions 3 Programming Instructions 4 Programming the VT-3........4 Programming the VT-3U...9
More informationNON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT
Model No. PEL00581 NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT 1 Please read these instructions carefully before starting installation and retain for future reference. The centre page
More informationLOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA
LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution
More informationCellwatch Electrical Installation
Tech20081110-1-1 Cellwatch Electrical Installation Critical Distances...2 Typical Layout...3 Typical ibmu Placement...4 Typical Control Unit Placement...5 Physical Mounting and Location - General...6 CU
More informationSMX Lumi-Hub Installation Guide
SMX Lumi-Hub SMX Lumi-Hub Installation Guide 85mm (3.35in) 70mm (2.76in) 85mm (3.35in) 70mm (2.76in) 151mm (5.94in) Lid Removed 53mm (2.09in) Tools Required Small Flat-Blade Screwdriver Large Screwdriver
More informationRE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW
Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No
More informationECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES
ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES TECHNICAL AND INSTALLATION DOCUMENTATION STOKVIS ENERGY SYSTEMS UNIT 34 CENTRAL PARK ESTATE 34 CENTRAL PARK ESTATE WEST
More informationControl Box Wiring For PRSstandard Tool
888-680-4466 ShopBotTools.com Control Box Wiring For PRSstandard Tool Copyright 2018 ShopBot Tools, Inc. page 1 Table of Contents Introduction...5 Installation...5 Powering the PRSstandard Control Box...5
More informationJEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market
1 888-323-8755 www.nwlifts.com JEEVES Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market This manual will cover the installation procedure step-by-step. The installation of this dumbwaiter
More information331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH
331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing
More informationACC Series Power Conditioner OPERATION & INSTALLATION MANUAL
ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide
More informationElectric Stone Hearth Oven
Beech Electric Oven Manual_R5.doc Page 1 of 12 2012-05-08 (C) Electric Stone Hearth Oven The Beech Ovens electric Stone Hearth oven has been developed to include an in-floor electric element and a smooth
More informationControl Box Wiring For PRSstandard Tool
888-680-4466 ShopBotTools.com Control Box Wiring For PRSstandard Tool Copyright 2017 ShopBot Tools, Inc. page 1 Copyright 2017 ShopBot Tools, Inc. page 2 Table of Contents Introduction...5 Installation...5
More informationUSER MANUAL PNEUMATIC TIME DELAY SWITCH
USER MANUAL PNEUMATIC TIME DELAY SWITCH TS40 & TS41 IP20 IMPORTANT NOTICE! This device should be installed by a qualified electrician in accordance with the latest edition of the IEE Wiring Regulations
More informationREVISION HISTORY REVISION HISTORY
FILTER CONTROLLER REVISION HISTORY Filter Flush Controller forms part of the Netafim range of filtration controllers all designed to make filteration more reliable and economical.. Contact any of the Netafim
More informationGenerator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit
Instruction Sheet 10 2004 Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit 541 0810 GENERAL INFORMATION This kit contains one Control Communications Module (CCM-G) with
More information- Wiring Brochure Mixing Expansion Module 440
- Wiring Brochure Mixing Expansion Module 440 W 440 12/08 1 Information Brochure Choose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More informationEXI LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION
INTRODUCTION The range brings all the benefits of an LED source to our popular EXI range of Exit Sign luminaires. This luminaire range offers significant energy savings and minimal maintenance compared to
More informationLED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR
INTRODUCTION The LED AC Driverless Floodlights with PIR include a hanging / mounting bracket and a 100cm cable. SPECIFICATION LED 800-4000lm IP65 180-240V IK07 6000K 50Hz >80 Ra 10W- 50W Dimensions: FLAC10BPIR:
More informationSingle gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting,
Single gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting, heating and ventilation loads up to 10A installation
More informationCHECKLIST & COMPONENTS
Eclipse Compact www.rollershuttercompany.com Tel 0800 6444121 55mm Roller Garage Doors CHECKLIST & COMPONENTS EQUIPMENT REQUIRED 2 x Step ladders or hop ups Spirit level Tape measure Power drill 10mm A/F
More informationSieve Shaker 200mm/300mm - 8/12 inch SV003
Sieve Shaker 200mm/300mm - 8/12 inch SV003 CONTENTS Introduction Specification Installation Controls Operation Maintenance Spares and Accessories 1 Introduction The unique action of this Sieve Shaker (Fig
More informationELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102
INSTALLATION INSTRUCTION ELECTRIC HEAT ACCESSORY 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL-15 CONTENTS GENERAL...2 NOTES, CAUTIONS AND WARNINGS........... 2 REFERENCE...2
More informationAUTOMATIC SPRINKLER TIMER
AUTOMATIC SPRINKLER TIMER Owner s Manual PRT-4 / PRT-6 For use with standard 24 VAC automatic sprinkler valves. These timers are designed for use in any 110 VAC /60 Hz ±10% AC outlet (240 VAC, 50 HZ for
More informationTHX & TIX Lumi-Hub Installation Guide
THX & TIX Lumi-Hub THX & TIX Lumi-Hub Installation Guide 110mm (4.33in) 90mm (3.54in) 110mm (4.33in) 90mm (3.54in) 177mm (6.96in) Lid Removed 65mm (2.56in) Tools Required Small Flat-Blade Screwdriver Large
More information825-P Modular Protection System for motors Specification Guide
Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection
More information- Wiring Brochure Universal Reset Module 422e
- Wiring Brochure Universal Reset Module 422e W 422e 01/08 1 Information Brochure hoose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in
More informationSDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual
SDM320D / SDM320A DIN Rail Single Phase Two Wire Energy Meter with S0 Pulse Output (Four modular) User Manual ------------------- 1.1 Safety instruction 1.2 Introductions 1.3 Performance criteria 1.4 Specifications
More informationCovers All 430, 440, 441 and CJ Series Advanced Security Systems.
INSTALL GUIDE Covers All 430, 440, 441 and CJ Series Advanced Security Systems www.ultrastarters.com Technical Support: 866-698-5872 ext 0 support@ultrastarters.com FCC/ID Notice This device complies with
More information24V 3A EN54 Ancillary Power Supply
24V 3A EN54 Ancillary Power Supply Normal supply - green light on Fault condition - call Engineer Control relay - activated 3A Power Supply C-TEC Manufactured in England by C-Tec EN 54-4 : 1997 INSTALLATION
More informationOPERATOR S MANUAL HWH COMPUTER-CONTROLLED 2000 SERIES LEVELING SYSTEM. FEATURING: Single Step Touch Panel Control Air Leveling
OPERATOR S MANUAL HWH COMPUTER-CONTROLLED 000 SERIES LEVELING SYSTEM R HWH CORPORATION R FEATURING: Single Step Touch Panel Control Air Leveling HWH COMPUTERIZED LEVELING LEVEL AIR EXCESS SLOPE MODE DUMP
More informationThis page intentionally left blank.
Sel fencl osedshark MeterAssem bl y ForRet r of i tmet ersol ut i ons Ex t endsswi t chgearcapabi l i t y Pr ewi r edandconf i gur ed El i mi nat eswi r i ngandi ns t al l at i oner r or s This page intentionally
More informationBMS RS-485 Card/Box Quick Guide Applicable for hybrid inverter 3KW-10KW
Thank you for purchasing RS485 card/box. This manual contains instructions and warnings that should be followed during the installation, operating and storage of the card. Please keep this manual for further
More informationTRAC-Station BT Installation Instructions
TRAC-Station BT Installation Instructions P/N 10103024P1 November 2011 2011 UTC Fire & Security. All rights reserved. Introduction This is the Supra TRAC-Station BT Installation Instructions. Read these
More informationTurn your excess solar into hot water. Installation Instructions - GREEN CATCH
Installation Instructions - GREEN CATCH IMPORTANT: This product must be installed by a licensed electrician. This product must be installed According to the AS3000 Australian Wiring Standards. Inside the
More informationAutomatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit
Instruction Sheet 10-2004 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch.
More informationTable 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm.
float switches Mechanical Float Switch Mechanically activated float switches offer a reliable low current control for dewatering applications. How It Works The mechanical float switch control will turn
More informationUser Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring
User Manual JS-ICON 624 ARCH Dimmer Rack JOHNSON SYSTEMS INC. Spring 2007 2002161 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS [1] Description: Tow Hitch Wire Harness Kit [2] Application: Nissan Rogue Note: Tow Harness application is limited to specific vehicle option packages that include tow harness
More informationIECEx Certificate of Conformity
Certificate of Conformity: IECEx BAS 07.0033X http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/9e9052... Page 1 of 4 18/06/2008 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL
More informationElectric Range installation manual
Electric Range installation manual This manual is made with 100% recycled paper. imagine the possibilities ENGLISH Thank you for purchasing this Samsung product. To receive more complete service, please
More informationSINGLE DUCT TERMINAL UNITS
www.igcaire.com SINGLE DUCT TERMINAL UNITS Direct Digital Control, Pressure Independent FEATURES 22 Gauge Galvanized Steel Casing Construction with a 20 Gauge Casing Option that Provides Strength and Product
More informationModel LA 4100 Time Delay OFF Controller
ISIMET LA Series Model LA 4100 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller operates as a single output controller where the application
More informationTechnical Specificaions. kwh Energy Meter
Technical Specificaions of kwh Energy Meter (SPK300) Class 1.0S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com
More informationPIL0478 ISSUE 01/ 07/16
ISSUE 01/ 07/16 PIL0478 ZAFIR G9 CEILING FITTING PIL0478 ISSUE 01/ 07/16 PART C PART E PART 21 SELV 1 1.B 1 3.1 3.3 3.4 3.5 3.6, 3.8 3.10 3.12 3.14 3.16 3.17 3.18 3.19 3.19 ATTENTION! THE TABLE BELOW
More informationSOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V
SOLAR LIGHTING CONTROLLER OPERATOR S MANUAL SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V 10A / 12V 10A / 24V 20A / 12V 20A / 24V 1098 Washington Crossing Road Washington Crossing,
More information- Wiring Brochure Universal Reset Module 422
- Wiring Brochure Universal Reset Module 422 W 422 03/09 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 Rough-in Wiring Rough-in
More informationCentrifuge Operator / Service Manual
3000 Centrifuge Centrifuge Operator / Service Manual cat.# 26230 & 26231 The Q-sep 3000 centrifuge complies with all requirements of UL standard 3101 20, Can/CSA C22.2 No. 1010.1, and Can/CSA C22.2 No.
More information9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard
9200 Revenue Meter This document applies to 9200 meters with firmware version 205 or greater, and explains how to set up and seal the meter for revenue functionality. Revenue meters provide power measurements
More informationSymmetra PX kw 208 V. Installation 01/
Symmetra PX 10 40 kw 208 V Installation 01/2016 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries SAS referred to
More informationi RANGE HYDROPATH Technology The home of
i RANGE HYDROPATH Technology The home of Input Voltage 87-240V AC Input Frequency 47-63 Hz Material Specifications Main unit: Anodised Aluminium End plates: UL V-0 rated polycarbonate Water and Dust Protection
More informationmygrid Installation Notes
mygrid Introduction mygrid kits provide an easy to install, compliant, Solar Hybrid (On-Grid) or Off-Grid battery system. These installation notes outline all the processes required to effectively install
More informationD-FORCE1500PV GARAGE DOOR OPENER
D-FORCE1500PV GARAGE DOOR OPENER WARNING: IT IS VITAL FOR THE SAFETY OF ALL PERSONS INSTALLING AND USING THIS OPENER TO FOLLOW THE INSTALLATION INSTRUCTIONS AND SAFETY WARNINGS. FAILURE TO COMPLY MAY RESULT
More informationAquiTron. AT-PIR-SOV Water Shut-Off System INSTALLATION INSTRUCTIONS
AquiTron Water Shut-Off System INSTALLATION INSTRUCTIONS System Please read these instructions carefully and keep them in a safe place (preferably close to the module) for future reference. These instructions
More informationSure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards
049-289 Sure-Lites Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. WARNING Risk of Fire/Electric Shock If not qualified, consult an electrician. WARNING Risk
More informationSafety Lampholders and Pendants
Safety Lampholders and Pendants Safety products are designed to make life easy for you. When the lamp is removed from the lamp holder body the power is automatically disconnected at the contacts - ensuring
More informationYour Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)
Your Guide to the Installation, Care and maintenance of PERFORMA Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027) Pegler Limited, St Catherine s Avenue, Doncaster DN4 8DF Telephone
More informationADVANCED PID TROUBLESHOOTING
ADVANCED PID TROUBLESHOOTING August 29, 2016 A KEY POINT If the drive is telling you something via a Fault, then the problem is probably not the drive. The drive is recognizing a fault and telling you
More informationModel LA 4400 Time Delay OFF Controller
ISIMET LA Series Model LA 4400 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller with integral 24-hr. programmable time clock operates
More informationTemperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A
Temperature Control Panel Wiring Diagram Model: ISPA-0-P-5A Shift Controls, Inc. Installed Options: TC Jack Panel Connector Interlock Relay, RLY- 5A Power Cord www.shift-controls.com support@shift-controls.com
More information1.Safe testing IMPORTANT:
Electricity is dangerous and can cause injury and death. Always treat it with the greatest of respect and care. If you are not quite sure how to proceed, then stop, take advice from a qualified person.
More informationINSTALLATION INSTRUCTIONS. Timer Features
TT-403 4/6c INSTALLATION INSTRUCTIONS Original Issue Date: /04 Model: RDT, HDT, and KSS-J Automatic Transfer Switches Market: ATS Subject: Programmable Exerciser Kits GM47597-KA, -KA, KA3, -KP, -KP, and
More informationInstallation Instructions for TLCFJCRUISERA Toyota Landcruiser FJ Cruiser 125lt Auxiliary Tank
Installation Instructions for TLCFJCRUISERA Toyota Landcruiser FJ Cruiser 125lt Auxiliary Tank This Auxiliary Fuel Tank fits up under the rear of the vehicle. The standard filler neck is replaced with
More informationBurden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM
Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0
More informationInstallation & Set Up Guide
Installation & Set Up Guide A fully automated pool and spa water leveling System Full Electrical Certification Inside & outside use (V99086) C-Tick Approval N11116 Index Page 1: Three Main Components Page
More informationGE Grid Solutions. Multilin Meter Enclosure. Instruction Manual. Manual P/N: A4 Manual Order Code: GEK C LISTED * A4*
GE Grid Solutions Multilin Meter Enclosure Instruction Manual Manual P/N: 1601-9215-A4 Manual Order Code: GEK-119545C *1601-9215-A4* LISTED Copyright 2017 GE Multilin Inc. All rights reserved. Multilin
More informationKENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO
BILL 1 MAINS POWER DISTRIBUTION 2-1 ITEM DESCRIPTION QTY UNIT RATE AMOUNT Supply, install, test, commission and set to work the following:- 1.01 Free-standing purpose made front access sub main switchboard
More informationOptimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version
Optimal Series Automatic Transfer Switch Installation and User Manual for the OPT2225 Automatic Transfer Switch Full Version File: OPT2225 Rev2.5.doc November, 2004 2 Thank You For Purchasing This DynaGen
More informationRichdel 300 SERIES MECHANICAL CONTROLLERS INSTALLATION AND OPERATING GUIDE FOR ALL MODELS
Richdel 300 SERIES MECHANICAL CONTROLLERS INSTALLATION AND OPERATING GUIDE FOR ALL MODELS INSTALLATION INSTRUCTIONS The 300 Series Controllers are operated by electric motors and require 24 volts AC current
More informationw w w. h d o n l i n e s h o p. d e CHROME FAN KIT GENERAL INSTALLATION -J04347 REV Kit Number Models Kit Contents
-J0447 REV. 008-08-05 CHROME FAN KIT GENERAL Kit Number 996-08 Models For model fitment information, see the P&A Retail Catalog or the Parts and Accessories section of www.harley-davidson.com (English
More informationATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions
to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They
More informationTECHNICAL DOCUMENT. PCNC Mill Enclosure Door Switch Kit. Installation
PCNC Mill Enclosure Door Switch Kit Product Identification: Enclosure Door Switch Kit (PN 35550) Purpose: This document details installation and use of the Enclosure Door Switch Kit on either a PCNC 770
More informationUser Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736
User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer
More informationCD100 Series. Operators Manual SINGLE COLUMN CARD DISPENSER
CD100 Series SINGLE COLUMN CARD DISPENSER Operators Manual Contents 1 Specifications...1 2 Installation...2 2.1 Unpacking and inspection...2 2.2 Installation...2 2.3 Electrical Connections...2 2.4 Initial
More informationJBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER
JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality
More information24 Hour Immersion Heater Time Controller
24 Hour Immersion Heater Time Controller Model: TS900N Installation & Operating Instructions 1 1. General Information These instructions should be read carefully and retained for further reference and
More informationCOUNTIS E22 Three-phase energy meter Direct - 80 A
Instruction manual COUNTIS E22 Three-phase energy meter Direct - 80 A EN www.socomec.com/ en/countis-e2x EN Contents 1. Documentation.... 3 2. Hazards and warnings... 4 2.1. Risk of electrocution, burns
More informationPORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0
PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0 MM September 21, 2012 TABLE OF CONTENTS Section Number DANGER INTRODUCTION AND TECHNICAL SPECIFICATIONS 1 CONTROL AND METERING DESCRIPTION 2 OPERATION
More informationBTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)
BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS) Programmable Automatic Transfer Switch Operation Manual Main Switch Rated Current 2P/3P/4P 250Amp 2P 400 Amp Main Switch Rated Voltage 690 Vac Taiwan Patent Number
More informationPREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.
EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL GLT.MAN-138 CONTENTS Introduction to the Premier Power Pack PSU... 2 Changes to EN54-4 (The Fire Alarm Equipment Power Supply Standard)... 3 Indications... 4
More information