1 EE462 Electric Machines PROJECT REPORT VARIABLE SPEED DC MOTOR DRIVE Done By: ID# NAME SEC# Tel# Al-Hajjaj, Muhammad Done for: Dr. M. Abido Due date 21 May

2 TABLE OF CONTENTS 1.0 DC MOTOR THEORY Torque Generator Action in a Motor DC Motor Theory Summary TYPES OF DC MOTORS DC DRIVE FUNDAMENTALS DC MOTORS TYPICAL ADJUSTMENTS DC DRIVES - PRINCIPLES OF OPERATION DC MOTOR CONTROL CHARACTERISTICS TYPES OF VARIABLE SPEED DC DRIVES RECOMMENDATIONS CONCLUSIONS REFERENCES 46 2

3 1.0 DC MOTOR THEORY: Inducing a Force on a Conductor. There are two conditions which are necessary to produce a force on a conductor: i. The conductor must be carrying current. ii. The conductor must be within a magnetic field. When these two conditions exist, a force will be applied to the conductor, which will attempt to move the conductor in a direction perpendicular to the magnetic field. This is the basic theory by which all DC motors operate. Theory of Operation (Figure 1), Left-Hand Rule for Current-Carrying Conductors Every current-carrying conductor has a magnetic field around it. The direction of this magnetic field may be found by using the left-hand rule for currentcarrying conductors. When the thumb points in the direction of current flow, the fingers will point in the direction of the magnetic field produced, as shown in Figure 1. If a current-carrying conductor is placed in a magnetic field, the combined fields will be similar to those shown in Figure 2. The direction of current flow through the conductor is indicated with an "x" or a " ". The "x" indicates the current flow is away from the reader, or into the page. The " " indicates the current flow is towards the reader, or out of the page. Figure 1: Left-Hand Rule for Current-Carrying Conductors 3

4 Figure 2: Current-Carrying Conductor in a Magnetic Field Above the conductor on the left, the field caused by the conductor is in the opposite direction of the main field, and therefore, opposes the main field. Below the conductor on the left, the field caused by the conductor is in the same direction as the main field, and therefore, aids the main field. The net result is that above the conductor the main field is weakened, or flux density is decreased; below the conductor the field is strengthened, or flux density is increased. A force is developed on the conductor that moves the conductor in the direction of the weakened field (upward). Above the conductor on the right, the field caused by the conductor is in the same direction as the main field, and therefore, aids the main field. Below the conductor on the right, the field caused by the conductor is in the opposite direction of the main field, and therefore, opposes the main field. The net result is that above the conductor the field is strengthened, or flux density is increased, and below the conductor, the field is weakened, or flux density is decreased. A force is developed on the conductor that moves the conductor in the direction of the weakened field (downward). In a DC motor, the conductor will be formed in a loop such that two parts of the conductor are in the magnetic field at the same time, as shown in Figure 3. This combines the effects of both conductors to distort the main magnetic field and produce a force on each part of the conductor. When the conductor is placed on a rotor, the force exerted on the conductors will cause the rotor to rotate clockwise, as shown on Figure 3. You can think of these magnetic lines of force as rubber bands that are always trying to shorten themselves. The lines of force above the 4

5 conductor exert a downward force due to the magnetic lines of force trying to straighten themselves. Figure 3: Motor Action The above explanation of how a force is developed is convenient; however, it is somewhat artificial. It is based on a fundamental principle of physics which may be stated as follows: "A current-carrying conductor in a magnetic field tends to move at right angles to that field." Another important way to show the relationship between the current-carrying conductor, magnetic field, and motion, is the right-hand rule for motors, as shown in Figure 4. Figure 4: Right hand rule for motors 5

6 The right-hand rule for motors shows the direction in which a current-carrying conductor moves in a magnetic field. When the forefinger is pointed in the direction of the magnetic field lines, and the center finger is pointed in the direction of current flow, the thumb will point in the direction of force (motion). 1.1 Torque Torque is defined as that force which tends to produce and maintain rotation. The function of torque in a DC motor is to provide the mechanical output or drive the piece of equipment that the DC motor is attached to. When a voltage is applied to a motor, current will flow through the field winding, establishing a magnetic field. Current will also flow through the armature winding, from the negative brush to the positive brush as shown in Figure 5. Since the armature is a current- carrying conductor in a magnetic field, the conductor has a force exerted on it, tending to move it at right angles to that field. Using the left-hand rule for current- carrying conductors, you will see that the magnetic field on one side is strengthened at the bottom, while it is weakened on the other side. Using the right-hand rule for motors, we can see that there is a force exerted on the armature which tends to turn the armature in the counter-clockwise direction. The sum of the forces, in pounds, multiplied by the radius of the armature, in feet, is equal to the torque developed by the motor in pound-feet (1b - ft). It is evident from Figure 5 that if the armature current was reversed, but the field was the same, torque would be developed in the opposite direction. Likewise, if the field polarities were reversed and the armature remained the same, torque would also be developed in the opposite direction. The force that is developed on a conductor of a motor armature is due to the combined action of the magnetic fields. The force developed is directly proportional to the strength of the main field flux and the strength of the field around the armature conductor. As we know, the field strength around each armature conductor depends on the amount of current flowing through the armature conductor. 6

7 Figure 5: Armature Current in a Basic DC Motor T = KFI a Where T = torque, lb-ft, K = a constant depending on physical size of motor, F = field flux, number of lines of force per pole I a = armature current 1.2 Generator Action in a Motor A generator action is developed in every (CEMF) motor. When a conductor cuts lines of force, an EMF is induced in that conductor. Current to start the armature turning will flow in the direction determined by the applied DC power source. After rotation starts, the conductor cuts lines of force. By applying the left-hand rule for generators, the EMF that is induced in the armature will produce a current in the opposite direction. The induced EMF, as a result of motor operation, is called counter electromotive force, or CEMF, as illustrated in Figure 6. 7

8 Figure 6: Counter electromotive Force (CEMF) 1.3 DC Motor Theory Summary There are two conditions necessary to produce a force on a conductor: - i. The conductor must be carrying current. ii. The conductor must be within a magnetic field. The right-hand rule for motors states that when the forefinger is pointed in the direction of the magnetic field lines, and the center finger is pointed in the direction of current flow, the thumb will point in the direction of motion. The function of torque in a DC motor is to provide the mechanical output to drive the piece of equipment that the DC motor is attached to. Torque is developed in a DC motor by the armature (current-carrying conductor) being present in the motor field (magnetic field). CEMF is developed in a DC motor by the armature (conductor) rotating (relative motion) in the field of the motor (magnetic field). The function of the voltage that is developed in a DC motor (CEMF) opposes the applied voltage and results in the lowering of armature current. The speed of a DC motor may be changed by using resistors to vary the field current and, therefore, the field strength. 1.4 TYPES OF DC MOTORS There are three basic types of dc motors: (1) Series motors. (2) Shunt motors, and (3) compound motors. They differ largely in the method in which their field and armature coils are connected. 8

9 Series DC Motor In the series motor, the field windings, consisting of a relatively few turns of heavy wire, are connected in series with the armature winding. The same current flowing through the field winding also flows through the armature winding. Any increase in current, therefore, strengthens the magnetism of both the field and the armature. Because of the low resistance in the windings, the series motor is able to draw a large current in starting. This starting current, in passing through both the field and armature windings, produces a high starting torque, which is the series motor's principal advantage. The speed of a series motor is dependent upon the load. Any change in load is accompanied by a substantial change in speed. A series motor will run at high speed when it has a light load and at low speed with a heavy load. If the load is removed entirely, the motor may operate at such a high speed that the armature will fly apart. If high starting torque is needed under heavy load conditions, series motors have many applications. Series motors are often used in aircraft as engine starters and for raising and lowering landing gears, cowl flaps, and wing flaps. Shunt DC Motor In the shunt motor the field winding is connected in parallel or in shunt with the armature winding. The resistance in the field winding is high. Since the field winding is connected directly across the power supply, the current through the field is constant. The field current does not vary with motor speed, as in the series 9

10 motor and, therefore, the torque of the shunt motor will vary only with the current through the armature. The torque developed at starting is less than that developed by a series motor of equal size. The speed of the shunt motor varies very little with changes in load. When all loads are removed, it assumes a speed slightly higher than the loaded speed. This motor is particularly suitable for use when constant speed is desired and when high starting torque is not needed. Compound DC Motor The compound motor is a combination of the series and shunt motors. There are two windings in the field: a shunt winding and a series winding. The shunt winding is composed of many turns of fine wire and is connected in parallel with the armature winding. The series winding consists of a few turns of large wire and is connected in series with the armature winding. The starting torque is higher than in the shunt motor but lower than in the series motor. Variation of speed with load is less than in a series wound motor but greater than in a shunt motor. The compound motor is used whenever the combined characteristics of the series and shunt motors are desired. Like the compound generator, the compound motor has both series and shunt field windings. The series winding may either aid the shunt wind (cumulative compound) or oppose the shunt winding (differential compound). The starting and load characteristics of the cumulative compound motor are somewhere between those of the series and those of the shunt motor. 10

11 Because of the series field, the cumulative compound motor has a higher starting torque than a shunt motor. Cumulative compound motors are used in driving machines which are subject to sudden changes in load. They are also used where a high starting torque is desired, but a series motor cannot be used easily. In the differential compound motor, an increase in load creates an increase in current and a decrease in total flux in this type of motor. These two tend to offset each other and the result is a practically constant speed. However, since an increase in load tends to decrease the field strength, the speed characteristic becomes unstable. Rarely is this type of motor used in aircraft systems. Counter E.M.F. The armature resistance of a small, 28 volt dc motor is extremely low, about 0.1 ohms. When the armature is connected across the 28 volt source, current through the armature will apparently be This high valve of current flow is not only impracticable but also unreasonable, especially when the current drain, during normal operation of a motor, is found to be about 4 amperes. This is because the current through a motor armature during operation is determined by more factors than ohmic resistance. When the armature in a motor rotates in a magnetic field, a voltage is induced in its windings. This voltage is called the back or counter e.m.f. (electromotive force) and is opposite in direction to the voltage applied to the motor from the external source. Counter e.m.f. opposes the current which causes the armature to rotate. The current flowing through the armature, therefore, decreases as the counter e.m.f. increases. The faster the armature rotates, the greater the counter e.m.f. For this reason, a motor connected to a battery may draw a fairly high current on starting, but as the armature speed increases, the current flowing through the armature decreases. At rated speed, the counter e.m.f. may be only a few volts less than the battery voltage. Then, if the load on the motor is increased, the motor will slow down, less counter e.m.f. will be generated, and the current drawn from the external source will increase. In a shunt motor, the counter e.m.f. affects only the current in the armature, since the field is connected in parallel across the power source. As the motor slows down and the counter e.m.f. decreases, more current flows through the armature, but the magnetism in the field is unchanged. When the series motor slows down, the counter e.m.f. decreases and more current flows 11

12 through the field and the armature, thereby strengthening their magnetic fields. Because of these characteristics, it is more difficult to stall a series motor than a shunt motor. Types of Duty Electric motors are called upon to operate under various conditions. Some motors are used for intermittent operation; others operate continuously. Motors built for intermittent duty can be operated for short periods only and, then, must be allowed to cool before being operated again. If such a motor is operated for long periods under full load, the motor will be overheated. Motors built for continuous duty may be operated at rated power for long periods. Reversing Motor Direction By reversing the direction of current flow in either the armature or the field windings, the direction of a motor's rotation may be reversed. This will reverse the magnetism of either the armature or the magnetic field in which the armature rotates. If the wires connecting the motor to an external source are interchanged, the direction of rotation will not be reversed, since changing these wires reverses the magnetism of both field and armature and leaves the torque in the same direction as before. One method for reversing direction of rotation employs two field windings wound in opposite directions on the same pole. This type of motor is called a split field motor. The single pole, double throw switch makes it possible to direct current through either of the two windings. When the switch is placed in the lower position, current flows through the lower field winding, creating a north pole at the lower field winding and at the lower pole piece, and a south pole at the upper pole piece. When the switch is placed in the upper position, current flows through the upper field winding, the magnetism of the field is reversed, and the armature rotates in the opposite direction. Some split field motors are built with two separate field windings wound on alternate poles. The armature in such a motor, a four pole reversible motor, rotates in one direction when current flows through the windings of one set of opposite pole pieces, and in the opposite direction when current flows through the other set of windings. Another method of direction reversal, called the switch method, employs a double pole, double throw switch which changes the direction of current flow in either the armature or the field. In the illustration of the switch method. Current direction may be reversed through the field but not through the armature. When the switch is thrown to the "up" position, current flows through the field winding to establish 12

13 a north pole at the right side of the motor and a south pole at the left side of the motor. When the switch is thrown to the "down" position, this polarity is reversed and the armature rotates in the opposite direction. Motor Speed Motor speed can be controlled by varying the current in the field windings. When the amount of current flowing through the field windings is increased, the field strength increases, but the motor slows down since a greater amount of counter e.m.f. is generated in the armature windings. When the field current is decreased, the field strength decreases, and the motor speeds up because the counter e.m.f. is reduced. A motor in which speed can be controlled is called a variable speed motor. It may be either a shunt or series motor. In the shunt motor, speed is controlled by a rheostat in series with the field windings. The speed depends on the amount of current which flows through the rheostat to the field windings. To increase the motor speed, the resistance in the rheostat is increased, which decreases the field current. As a result, there is a decrease in the strength of the magnetic field and in the counter e.m.f. This momentarily increases the armature current and the torque. The motor will then automatically speed up until the counter e.m.f. increases and causes the armature current to decrease to its former value. When this occurs, the motor will operate at a higher fixed speed than before. To decrease the motor speed, the resistance of the rheostat is decreased. More current flows through the field windings and increases the strength of the field; then, the counter e.m.f. increases momentarily and decreases the armature current. As a result, the torque decreases and the motor slow down until the counter e.m.f. decreases to its former value; then the motor operates at a lower fixed speed than before. The rheostat speed control is connected either in parallel or in series with the motor field, or in parallel with the armature. When the rheostat is set for maximum resistance, the motor speed is increased in the parallel armature connection by a decrease in current. When the rheostat resistance is maximum in the series connection, motor speed is reduced by a reduction in voltage across the motor. For above normal speed operation, the rheostat is in parallel with the series field. Part of the series field current is bypassed and the motor speeds up. Energy Losses in DC Motors Losses occur when electrical energy is converted to mechanical energy (in the motor), or mechanical energy is converted to electrical energy (in the generator). 13

14 For the machine to be efficient, these losses must be kept to a minimum. Some losses are electrical, others are mechanical. Electrical losses are classified as copper losses and iron losses; mechanical losses occur in overcoming the friction of various parts of the machine. Copper losses occur when electrons are forced through the copper windings of the armature and the field. These losses are proportional to the square of the current. They are sometimes called I²R losses, since they are due to the power dissipated in the form of heat in the resistance of the field and armature windings. Iron losses are subdivided in hysteresis and eddy current losses. Hysteresis losses are caused by the armature revolving in an alternating magnetic field. It, therefore, becomes magnetized first in one direction and then in the other. The residual magnetism of the iron or steel of which the armature is made causes these losses. Since the field magnets are always magnetized in one direction (DC field), they have no hysteresis losses. Eddy current losses occur because the iron core of the armature is a conductor revolving in a magnetic field. This sets up an e.m.f. across portions of the core, causing currents to flow within the core. These currents heat the core and, if they become excessive, may damage the windings. As far as the output is concerned, the power consumed by eddy currents is a loss. To reduce eddy currents to a minimum, a laminated core usually is used. A laminated core is made of thin sheets of iron electrically insulated from each other. The insulation between laminations reduces eddy currents, because it is "transverse" to the direction in which these currents tend to flow. However, it has no effect on the magnetic circuit. The thinner the laminations, the more effectively this method reduces eddy current losses. Inspection and Maintenance of DC Motors Use the following procedures to make inspection and maintenance checks: 1. Check the operation of the unit driven by the motor in accordance with the instructions covering the specific installation. 2. Check all wiring, connections, terminals, fuses, and switches for general condition and security. 3. Keep motors clean and mounting bolts tight. 14

15 4. Check brushes for condition, length, and spring tension. Minimum brush lengths, correct spring tension, and procedures for replacing brushes are given in the applicable manufacturer's instructions. 5. Inspect commutator for cleanness, pitting, scoring, roughness, corrosion or burning. Check for high mica (if the copper wears down below the mica, the mica will insulate the brushes from the commutator). Clean dirty commutators with a cloth moistened with the recommended cleaning solvent. Polish rough or corroded commutators with fine sandpaper (000 or finer) and blow out with compressed air. Never use emery paper since it contains metallic particles which may cause shorts. Replace the motor if the commutator is burned, badly pitted, grooved, or worn to the extent that the mica insulation is flush with the commutator surface. 6. Inspect all exposed wiring for evidence of overheating. Replace the motor if the insulation on leads or windings is burned, cracked, or brittle. 7. Lubricate only if called for by the manufacturer's instructions covering the motor. Most motors used in today's airplanes require no lubrication between overhauls. 8. Adjust and lubricate the gearbox, or unit which the motor drives, in accordance with the applicable manufacturer's instructions covering the unit. When trouble develops in a dc motor system, check first to determine the source of the trouble. Replace the motor only when the trouble is due to a defect in the motor itself. In most cases, the failure of a motor to operate is caused by a defect in the external electrical circuit, or by mechanical failure in the mechanism driven by the motor. Check the external electrical circuit for loose or dirty connections and for improper connection of wiring. Look for open circuits, grounds, and shorts by following the applicable manufacturer's circuit testing procedure. If the fuse is not blown, failure of the motor to operate is usually due to an open circuit. A blown fuse usually indicates an accidental ground or short circuit. The chattering of the relay switch which controls the motor is usually caused by a low battery. When the battery is low, the open circuit voltage of the battery is sufficient to close the relay, but with the heavy current draw of the motor, the voltage drops below the level required to hold the relay closed. When the relay opens, the voltage in the battery increases enough to close the relay again. This cycle repeats and causes chattering, which is very harmful to the relay switch, due to the heavy current causing an arc which will burn the contacts. 15

16 Check the unit driven by the motor for failure of the unit or drive mechanism. If the motor has failed as a result of a failure in the driven unit, the fault must be corrected before installing a new motor. If it has been determined that the fault is in the motor itself (by checking for correct voltage at the motor terminals and for failure of the driven unit), inspect the commutator and brushes. A dirty commutator or defective or binding brushes may result in poor contact between brushes and commutator. Clean the commutator, brushes, and brush holders with a cloth moistened with the recommended cleaning solvent. If brushes are damaged or worn to the specified minimum length, install new brushes in accordance with the applicable manufacturer's instructions covering the motor. If the motor still fails to operate, replace it with a serviceable motor. 16

17 2.0 DC DRIVE FUNDAMENTALS UNDERSTANDING DC DRIVES DC motors have been available for nearly 100 years. In fact the first electric motors were designed and built for operation from direct current power. AC motors are now and will of course remain the basic prime movers for the fixed speed requirements of industry. Their basic simplicity, dependability and ruggedness make AC motors the natural choice for the vast majority of industrial drive applications. Then where do DC drives fit into the industrial drive picture of the future? In order to supply the answer, it is necessary to examine some of the basic characteristics obtainable from DC motors and their associated solid state controls. 1. Wide speed range. 2. Good speed regulation. 3. Compact size and light weight (relative to mechanical variable speed). 4. Ease of control. 5. Low maintenance. 6. Low cost. In order to realize how a DC drive has the capability to provide the above characteristics, the DC drive has to be analyzed as two elements that make up the package. These two elements are of course the motor and the control. (The "control" is more accurately called the "regulator"). 2.1 DC MOTORS Basic DC motors as used on nearly all packaged drives have a very simple performance characteristic the shaft turns at a speed almost directly proportional to the voltage applied to the armature. Figure 1 shows a typical voltage/speed curve for a motor operating from a 115 volt control. 17

18 From the above curve you can see that with 9 volts applied to the armature, this motor would be operating at Point 1 and turn at approximately 175 RPM. Similarly with 45 volts applied, the motor would be operating at Point 2 on the curve or 875 RPM. With 90 volts applied, the motor would reach its full speed of 1750 RPM at point 3. From this example a general statement can be made that DC motors have "no load" characteristics that are nearly a perfect match for the curve indicated in Figure 1. However, when operated at a fixed applied voltage but a gradually increasing torque load, they exhibit a speed droop as indicated in Figure 2. This speed droop is very similar to what would occur if an automobile accelerator pedal was held in a fixed position with the car running on level ground. Upon starting up an incline where more driving torque would be needed, the car would slow down to a speed related to the steepness of the hill. In a real situation, the driver would respond by depressing the accelerator pedal to compensate for the speed loss to maintain a nearly constant speed up the incline. 18

19 In the DC drive a similar type of "compensation" is employed in the control to assist in maintaining a nearly constant speed under varying load (torque) conditions. The measurement of this tendency to slow down is called Regulation and is calculated with the following equation: % Regulation = No Load Speed - Full Load Speed No Load Speed X 100 In DC drives the regulation is generally expressed as a percentage of motor base speed. If the control (regulator) did not have the capability of responding to and compensating for changing motor loads, regulation of typical motors might be as follows: HP % MOTOR % MOTOR HP REGULATION REGULATION 1/ / / / One other very important characteristic of a DC motor should be noted. Armature amperage is almost directly proportional to output torque regardless of speed. This characteristic is shown by Figure 3. Point 1 indicates that a small fixed amount of current is required to turn the motor even when there is no output torque. This is due to the friction of the bearings, electrical losses in the motor materials and load imposed by the air in the motor (wind age). 19

20 Beyond Point 1 through Point 2 and 3, the current increases in direct proportion to the torque required by the load. From this discussion and Figure 3 a general statement can be made that for PM and Shunt Wound motors load torque determines armature amperage. In summary, two general statements can be made relative to DC motor performance. 1. Motor Speed is primarily determined by Applied Armature Voltage. 2. Motor Torque is controlled by Armature Current (amperes). Understanding these two concepts of DC motors provides the key to understanding total drive performance. REGULATORS (CONTROLS) The control provides two basic functions: 1. It rectifies AC power converting it to DC for the DC motor. 2. It controls the DC output voltage and amperage in response to various control and feedback signals thereby regulating the motor's performance, both in speed and torque. RECTIFYING FUNCTION The basic rectifying function of the control is accomplished by a combination of power semiconductors (Silicon Controlled Rectifiers and Diodes) that make up the "power bridge" assembly. 20

21 REGULATING FUNCTION The regulating function is provided by a relatively simple electronic circuit that monitors a number of inputs and sums these signals to produce a so called "error" signal. This error signal is processed and transformed into precisely timed pulses (bursts of electrical energy). These pulses are applied to the gates of the SCR's in the power bridge thereby regulating the power output to the DC motor. For most purposes it is not necessary to understand the electronic details of the regulator, however, in order to appreciate the regulator function it is good to understand some of the input signals that are required to give the regulator its capabilities, these are shown diagrammatically in Figure 4. The AC to DC power flow is a relatively simple straight through process with the power being converted from AC to DC by the action of the solid state power devices that form the power bridge assembly. The input and feedback signals need to be studied in more detail. SET POINT INPUT In most packaged drives this signal is derived from a closely regulated fixed voltage source applied to a potentiometer. 10 volts is a very common reference. The potentiometer has the capability of accepting the fixed voltage and dividing it down to any value of from, for example, 10 to zero volts, depending on where it is 21

22 set. A 10 volt input to the regulator from the speed adjustment control (potentiometer) corresponds to maximum motor speed and zero volts correspond to zero speed. Similarly any speed between zero and maximum can be obtained by adjusting the speed control to the appropriate setting. SPEED FEEDBACK INFORMATION In order to "close the loop" and control motor speed accurately it is necessary to provide the control with a feedback signal related to motor speed. The standard method of doing this in a simple control is by monitoring the armature voltage and feeding it back into the regulator for comparison with the input "set point" signal. When armature voltage becomes high, relative to the set point, established by the speed potentiometer setting, an "error" is detected and the output voltage from the power bridge is reduced to lower the motor's speed back to the "set point". Similarly when the armature voltage drops an error of opposite polarity is sensed and the control output voltage is automatically increased in an attempt to reestablish the desired speed. The "Armature Voltage Feedback System" which is standard in most packaged drives is generally called a "Voltage Regulated Drive". A second and more accurate method of obtaining the motor speed feedback information is called "Tachometer Feedback". In this case the speed feedback signal is obtained from a motor mounted tachometer. The output of this tachometer is directly related to the speed of the motor. Using Tachometer Feedback generally gives a drive improved regulation characteristics. When "Tachometer Feedback" is used the drive is referred to as a "Speed Regulated Drive". Most controls are capable of being modified to accept tachometer signals for operation in the tachometer feedback mode. In some newer high performance "digital drives" the feedback can come from a motor mounted encoder that feeds back voltage pulses at a rate related to motor speed. These (counts) are processed digitally being compared to the "set point" and error signals are produced to regulate the armature voltage and speed. CURRENT FEEDBACK The second source of feedback information is obtained by monitoring the motor armature current. As discussed previously, this is an accurate indication of the torque required by the load. 22

23 The current feedback signal is used for two purposes: 1. As positive feedback to eliminate the speed droop that occurs with increased torque load on the motor. It accomplishes this by making a slight corrective increase in armature voltage as the armature current increases. 2. As negative feedback with a "threshold" type of control that limits the current to a value that will protect the power semiconductors from damage. By making this function adjustable it can be used to control the maximum torque the motor can deliver to the load. The current limiting action of most controls is adjustable and is usually called "Current Limit" or "Torque Limit". In summary, the Regulator accomplishes two basic functions: 1. It converts the alternating Current to Direct Current. 2. It regulates the armature voltage and current to control the speed and torque of the DC Motor. 2.2 TYPICAL ADJUSTMENTS In addition to the normal external adjustment such as the speed potentiometer. There are a number of common internal adjustments that are used on simple small analog type SCR Drives (Silicon Controlled Rectifier Drive). Some of these adjustments are as follows: Minimum Speed Maximum Speed Current Limit (Torque Limit). IR Compensation Acceleration Time. Deceleration Time The following is a description of the function that these individual adjustments serve and their typical use. MINIMUM SPEED In most cases when the control is initially installed the speed potentiometer can be turned down to its lowest point and the output voltage from the control will go to zero causing the motor to stop. There are many situations where this is not desirable. For example there are some machines that want to be kept running at a minimum speed and accelerated up to operating speed as necessary. There is also a possibility that an operator may use the speed potentiometer to stop the motor to work on the machine. This can be a dangerous situation since the motor has only 23

24 been brought to a stop by zeroing the input signal voltage. A more desirable situation is when the motor is stopped by opening the circuit to the motor or power to the control using the on/off switch. By adjusting the minimum speed up to some point where the motor continues to run even with the speed potentiometer set to its lowest point, the operator must shut the control off to stop the motor. This adds a little safety into the system. The typical minimum speed adjustment is from 0 to 30% of motor base speed. MAXIMUM SPEED The maximum speed adjustment sets the maximum speed attainable either by raising the input signal to its maximum point or turning the potentiometer to the maximum point. For example on a typical DC motor the rated speed of the motor might 1750 RPM but the control might be capable of running it up to 1850 or 1900 RPM. In some cases it's desirable to limit the motor (and machine speed) to something less than would be available at this maximum setting. The maximum adjustment allows this to be done. By turning the internal potentiometer to a lower point the maximum output voltage from the control is limited. This limits the maximum speed available from the motor. In typical controls such as our BC140 the range of adjustment on the maximum speed is from 50 to 110% of motor base speed. CURRENT LIMIT One very nice feature of electronic speed controls is that the current going to the motor is constantly monitored by the control. As mentioned previously, the current drawn by the armature of the DC motor is related to the torque that is required by the load. Since this monitoring and control is available an adjustment is provided in the control that limits the output current to a maximum value. This function can be used to set a threshold point that will cause the motor to stall rather than putting out an excessive amount of torque. This capability gives the motor/control combination the ability to prevent damage that might otherwise occur if higher values of torque were available. This is handy on machines that might become jammed or otherwise stalled. It can also be used where the control is operating a device such as the center winder where the important thing becomes torque rather than the speed. In this case the current limit is set and the speed goes up or down to hold the tension 0 the material being wound. The current limit is normally factory set at 150% of the motor's rated current. This allows the motor to produce enough torque to start and accelerate the load and yet will not let the current (and torque) exceed 150% of its rated value when running. The range of adjustment is typically from 0 to 200% of the motor rated current. 24

25 IR COMPENSATION IR compensation is a method used to adjust for the droop in a motor's speed due to armature resistance. As mentioned previously, IR compensation is positive feedback that causes the control output voltage to rise slightly with increasing output current. This will help stabilize the motor's speed from a no load to full load condition. If the motor happens to be driving a load where the torque is constant or nearly so, then this adjustment is usually unnecessary. However, if the motor is driving a load with a widely fluctuating torque requirement, and speed regulation is critical, then IR compensation can be adjusted to stabilize the speed from the light load to full load condition. One caution is that when IR compensation is adjusted too high it results in an increasing speed characteristic. This means that as the load is applied the motor is actually going to be forced to run faster. When this happens it increases the voltage and current to the motor which in turn increases the motor speed further. If this adjustment is set too high an unstable "hunting" or oscillating condition occurs that is undesirable. ACCELERATION TIME The Acceleration Time adjustment performs the function that is indicated by its name. It will extend or shorten the amount of time for the motor to go from zero speed up to the set speed. It also regulates the time it takes to change speeds from one setting (say 50%) to another setting (perhaps 100%). So this setting has the ability to moderate the acceleration rate on the drive. A couple notes are important: if an acceleration time that is too rapid is called for "acceleration time" will be overridden by the current limit. Acceleration will only occur at a rate that is allowed by the amount of current the control passes through to the motor. Also important to note is that on most small controls the acceleration time is not linear. What this means is that a change of 50 RPM may occur more rapidly when the motor is at low speed than it does when the motor is approaching the set point speed. This is important to know but usually not critical on simple applications where these drives are used. DECELERATION TIME This is an adjustment that allows loads to be slowed over an extended period of time. For example, if power is removed from the motor and the load stops in 3 seconds, then the decal time adjustment would allow you' to increase that time and "power down" the load over a period of 4, 5, 6 or more seconds. Note: On a conventional simple DC drive it will not allow for the shortening of the time below the "coast to rest" time. 25

26 ADJUSTMENT SUMMARY The ability to adjust these six adjustments gives great flexibility to the typical inexpensive DC drive. In most cases the factory preset settings are adequate and need not be changed, but on other applications it may be desirable to tailor the characteristics of the control to the specific application. Many of these adjustments are available in other types of controls, such as variable frequency drives. 2.3 DC DRIVES - PRINCIPLES OF OPERATION DC drives, because of their simplicity, ease of application, reliability and favorable cost have long been a backbone of industrial applications. A typical adjustable speed drive using a silicon controller rectifier (SCR) power conversion' section, common for this type unit, is shown in Figure 2. The SCR, (also termed a thyristor) converts the fixed voltage alternating current (AC) of the power source to an adjustable voltage, controlled direct current (DC) output which is applied to the armature of a DC motor. SCR's provide a controllable power output by "phase angle control", so called because the firing angle (a point in time where the SCR is triggered into conduction) is synchronized with the phase rotation of the AC power source. If the device is triggered early in half cycle, maximum power is delivered to the motor; late triggering in the half cycle provides minimum power, as illustrated by Figure 3. The effect is similar to a very high speed switch, capable of being turned on and "conducted" off at an infinite number of points within each half cycle. This occurs at a rate of 60 times a second on a 60 Hz line, to deliver a precise amount of power to the motor. The efficiency of this form of power control is extremely high since a very small amount of triggering energy can enable the SCR (Silicon Controlled Rectifier) to control a great deal of output power. 26

27 2.4 DC MOTOR CONTROL CHARACTERISTICS A shunt-wound motor is a direct-current motor in which the field windings and the armature may be connected in parallel across a constant-voltage supply. In adjustable speed applications, the field is connected across a constant-voltage supply and the armature is connected across an independent adjustable-voltage supply. Permanent magnet motors have similar control characteristics but differ primarily by their integral permanent magnet field excitation. The speed (N) of a DC motor is proportional to its armature voltage; the torque (T) is proportional to armature current, and the two quantities are independent, as illustrated in Figure 5. CONSTANT TORQUE APPLICATIONS Armature voltage controlled DC drives are constant torque drives. They are capable of providing rated torque at any speed between zero and the base (rated) speed of the motor as shown by Figure 6. Horsepower varies in direct proportion to speed, and 100% rated horsepower is developed only at 100% rated motor speed with rated torque. CONSTANT HORSEPOWER APPLICATIONS Armature Controlled DC Drives - Certain applications require constant horsepower over a specified speed range. The screened area, under the horsepower curve in Figure 6, illustrates the limits of constant horsepower operation for armature controlled DC drives. As an example, the motor could provide constant horsepower between 50% speed and 100% speed, or a 2:1 range. However, the 50% speed point coincides with the 50% horsepower point. Any constant horsepower application may be easily calculated by multiplying the desired horsepower by the ratio of the speed range over which horsepower must remain constant. If 5 HP is required over a 2:1 range, an armature only controlled drive rated for 10 (5 x 2) horsepower would be required. Table 3 provides a convenient listing of horsepower output at various operating speeds for constant torque drives. 27

28 Field Controlled DC Drives - Another characteristic of a shunt-wound DC motor is that a reduction in field voltage to less than the design rating will result in an increase in speed for a given armature voltage. It is important to note, however, that this results in a higher armature current for a given motor load. A simple method of accomplishing this is by inserting a resistor in series with the field voltage source. This may be useful for trimming to an ideal motor speed for the application. An optional, more sophisticated method uses a variable voltage field source as shown by Figure 6. This provides coordinated automatic armature and field voltage control for extended speed range and constant HP applications. The motor is armature voltage controlled for constant torquevariable HP operation to base speed where it is transferred to field control for constant HP-variable torque operation to motor maximum speed. 2.5 TYPES OF DC DRIVES SIMOREG 6RA24 Siemens Variable Speed DC Drive Description & Standard Features SIMOREG Drive Controller The Siemens Motor Regulator (SIMOREG) is a state of the art, microprocessor based DC drive controller. This drive controller converts a three-phase, 50/60 Hz supply voltage into six pulse adjustable voltage to operate a DC motor. Output armature voltage varies directly with speed reference to provide constant torque operation from zero speed to base speed. Above base speed, the motor shunt field current may be decreased to further increase speed and provide a constant horsepower output up to maximum speed. The SIMOREG drive controller is designed to provide precise motor speed control over a wide range of machine parameters and load conditions. This software based controller will serve well as a packaged drive or as part of a drive system. Horsepower ranges include 1-250HP at 230VAC, HP at 460VAC input and 1500HP and higher at 600/650V AC input. All HP ratings are available as regenerative or non-regenerative drive controllers. Listed below are standard features, a partial list of adjustments, display parameters, service conditions, 28

29 diagnostics, and protection features. Consult the Technical Information Section for additional information. Standard Features The SIMOREG drive controller includes the following standard features: (Refer to the Technical Information Section for additional details.) Designed to meet the requirements of NEMA, IEEE, NEC, UL Listed and CSA Certified through 510A. 6 Pulse SCR (Silicon Controlled Rectifier) Bridge Microprocessor Control Board with 16 bit 38 MHz high performance multitasking microprocessor User interface keypad and digital display Power and interface control board Individual pulse transformers per SCR R/C snubbers across each SCR Current transformers for current regulator feedback Run/Ready light Plug-in wiring harness between boards Shunt field excitation circuitry with field current loss protection and field economizing circuit Terminal blocks for incoming/outgoing wiring connections Wire markers Fully rated contactor High speed AC power fuses 460/230: 115V AC control power Protection Tachometer loss and over speed Field current loss 12t motor overload Instantaneous over current Line tolerance monitoring Phase sequence monitoring Phase loss dv/dt Protection on the SCR's SCR type high speed AC line fuses DC output fuse on regenerative units Heat sink thermostat on fan cooled units Isolated electronics Diagnostics There are more than 120 diagnostic messages for troubleshooting, including fault and warning indication and memory retention of the last four faults. Some of the diagnostics include: Line voltage out of tolerance Line frequency unstable/out of tolerance Phase loss Motor stalled SCR failure detection and identification Loss of speed or voltage feedback Current overload EEPROM/Microprocessor malfunctions Quick Stop 29

30 transformer Power supply transformer Digitally fired burst type SCR gate pulses 1400PRV rated thyristors are standard Built-in AID converter accepts external reference sources Digital and analog tachometer generator feedback Serial communication via RS232 or RS485 serial ports General purpose P-I-D loop for additional regulation modes Freely programmable blocks for mathematical functions Software programming package to aid in start up Peer to Peer Link Tachometer to Voltage Feedback switching Four layer parameter 5 Binary and analog outputs Adjustments Priority access code protection Minimum speed Maximum speed Linear acceleration Linear deceleration S-Curve rounding Jog and thread speed presets Current limit Tapered current limit IR compensation for voltage feedback drives Motor armature current rating Motor field current rating Self turning routine automatically adjusts each SIMOREG drive controller to 8 Channel data storage Standard Displays include: Speed reference Operating speed Current reference Actual current Gating angle CEMF Armature voltage CEMF/Speed RMS AC phase to phase voltage All parameter set points Torque direction Operating time Field current reference Service Conditions 0-40 C Ambient Altitude: 3300 feet above sea level without derating (1000 meters) 95% Relative humidity (noncondensing) AC line voltage tolerance + 10%, -5% Frequency tolerance 48 to 62 Hz Data Subject to Change without Notice 30

31 optimum performance upon command Over speed with tachometer feedback CEMF crossover voltage (for field weakened speed ranges) (a) SIMOREG 6RA70 Siemens DC Master Variable Speed DC Drive Description & Base Drive Catalog Numbers Description & Base Drive Catalog Numbers Features Design and Mode of Operation o SIMOREG 6RA70 Converters o Parameterization Devices o Software Structure o Closed-Loop Functions in Armature Circuit o Closed-Loop Functions in Field Circuit o Optimization Run o Monitoring and Diagnosis o Functions of Inputs and Outputs o Safety Shutdown (E-STOP) o Serial Interface (i) Description Base Drive Description Series 6RA70 SIMOREG DC MASTER base drive converters are complete drive assemblies ready to be installed and operated. They include a 3-phase armature converter, single-phase field converter, main contactor, protective semiconductor fuses, control power transformer, and power / control terminals. Base drive converters are fully digital, compact units which supply the armature and field of variable speed DC drives with rated armature currents from 15A to 1660A. The motor field circuit can be supplied with DC currents of up to 40A (current levels depend on the armature rated current). 31

32 General Information Series 6RA70 SIMOREG DC MASTER Converters are characterized by their compact, space-saving construction. Their compact design makes them particularly easy to service and maintain since individual components are readily accessible. The electronics box contains the basic electronic circuitry as well as any supplementary option boards. All SIMOREG DC MASTER Units are equipped with a PMU simple operator panel mounted in the converter door. The panel consists of a five-digit, sevensegment display, three LED's as status indicators and three parameterization keys. The PMU also features connector X300 with an USS interface in accordance with the RS232 or RS485 standard. The panel provides all the facilities for making adjustments or settings and displaying measured values required to start-up the converter. The OP1 S optional converter operator panel can be mounted directly in the converter door or externally, e.g., in the cubicle door. When mounted remotely, the OP1 S can be connected to the converter with cables up to 5 meters (15 feet) length. Cable up to 200 meter (600 feet) in length can be used if a separate 5 VDC power supply is available. The OP1 S connects to the SIMOREG through connector X300 using the RS485 interface. The OP1 S can be installed as an economic alternative to conventional door mounted metering devices (Le. voltmeters, ammeters, and speed indicator). The OP1 S features a liquid crystal display with 4 x 16 characters for displaying parameter names in plain text. English, German, French, Spanish and Italian can be selected as the display languages. In addition the OP1 S can store parameter sets for easy downloading to other drives. The converter can also be parameterized on a standard PC with appropriate software connected to the serial interface on the basic unit. This PC interface is used during start-up, for maintenance during shutdown and for diagnosis in operation. Furthermore, converter software upgrades can be loaded through this interface for storage in flash memory. On single-quadrant converters, a fully controlled three-phase bridge supplies the armature. On four-quadrant converters, two fully controlled three-phase bridges are connected in an inverse-parallel connection to allow both positive and negative armature current. For the field converter, a single-phase, half-controlled 2-pulse bridge supplies the motor shunt field. 32

33 The armature and field converters can operate with AC line frequencies from 45 to 65 Hz. If required for a specific application, the frequency of the armature and field AC supplies can be different. The armature converter 3 phase AC supply is phase insensitive however on base drives rated 1180 and 1660 amperes, the 3 phase cooling fan must be connected to get the proper direction of rotation. The power section cooling system is monitored by means of temperature sensors. The power section for the armature and field converters is constructed of isolated thyristor modules for converters rated from 15A to 850A at 460V AG-line voltage. The heat sink in this case is electrically isolated and at ground potential. On converters rated 1180 and 1660 amperes at 460 VAC, the power section for the armature circuit is constructed using disk thyristors and the heat sinks are at line voltage potential. The housing and terminal covers on power connections provide protection against accidental contact for operators working in the vicinity. All connecting terminals are accessible from the front. All open and closed-loop drive control and communication functions are performed by two powerful microprocessors. Drive control functions are implemented in the software as program modules that can be "wired up" and changed by parameters. Rated DC Current: The rating plate of the converter module has 3 rated currents listed on it. The first two are IEG ratings and have no bearing on the base drive rating. The third rating is the US (NEMA) rating which the base drive rating is derived from. The US (NEMA) rated current allows operation at rated current followed by an overload of 150% for 60 seconds in a 45 G ambient. The overload can be applied no sooner than every 10 minutes. Base drives are designed using the US rating which means that fuses, contactors, and terminal blocks are sized for the rated US (NEMA) current. The IEG class I rating is the maximum current the power module can supply continuously with no overload. Because an overload is not possible the class I rated current is higher than the US rating. The IEG class I rating cannot be used with base drives because the base drive fuses, contactors, and terminal blocks will be overloaded. The microprocessor calculates the current 12t value of the power section cyclically to ensure that the thyristors are not damaged in overload operation. 33

34 Base Drive Catalog Numbers US RATING (Amps DC) 1-QUAD TYPE (Catalog No.) 4-QUAD TYPE (Catalog No.) 15 6RA7013-2FS22-0 6RA7013-2FV RA7018-2FS22-0 6RA7018-2FV RA7025-2FS22-0 6RA7025-2FV RA7030-2FS22-0 6RA7030-2FV RA7072-2FS22-0 6RA7072-2FV RA7075-2FS22-0 6RA7075-2FV RA7077-2FS22-0 6RA7077-2FV RA7082-2FS22-0 6RA7082-2FV RA7083-2FS22-0 6RA7083-2FV RA7087-2FS22-0 6RA7087-2FV RA7091-2FS22-0 6RA7091-2FV RA7094-2FS22-0 6RA7094-2FV Hp DC DRIVE The drive system will consist of one ADC/750 VDC six pulse drive cabinet. The power converter, SCR (Silicon Controlled Rectifier) heat sink bridges and High Horsepower command modules (6RA70) are manufactured by Siemens. Siemens control and firing technology is applied for superior operation of SCR gating, current, speed and monitoring of motor drive. Overload current limit is 150% for 1 min. every 10 min. The following features are included: One - modified Nema 12, two door cabinet. Mild steel construction measuring (90"x78"x30"). Paint is factory standard, ANSI 61 Gray. One Amp. Molded Case Switches mounted w/ through the door manual switch handle (pad lockable). One ADC 1-Quadrant SCR bridge assembly. 34

35 SCR AC line fusing. One - cabinet air cooling and filtration package. One - 85 ADC, single phase, Siemens field module and transformer. Customer supplied encoder feedback speed control as per customer drawings. One - main motor blower circuit V Max. Three digital meters for the following: Armature Amps, Armature Volts and Field Amps. Meters are mounted in the Master drive cabinet door. Siemens door mounted programming and fault indication keypad. Door mounted Hand/Off/Auto selector switch. Copper pad bus areas for incoming and out going AC/DC power connections. OPTIONAL ISOLATION TRANSFORMER (1) 1500 KVA with the following specifications: Primary Voltage 25 KV, 60 Hertz, 3 phase Delta, 1500 KVA Secondary Voltage 600/347 Wye, 1500 KVA Aluminum windings, 150 Deg. C rise, 220 Deg. C Insulation K-Factor 9 Nema 1 enclosure, floor mount 3000Hp DC DRIVE The drive system will consist of two ADC / 750 VDC six pulse drive cabinet sections. The power converter SCR (Silicon Controlled Rectifier) heat sink bridges are manufactured by Joliet Technologies and are fitted with Siemens High Horsepower command modules (6RA70). Siemens control and firing technology is applied for superior operation of SCR gating, current, speed and monitoring of motor drive. Each of the 2400 ADC sections work together by load sharing the high current demand. The drives will be designated as Master / Slave. By supplying each section with a single isolation transformer with two outputs Delta & Wye, we can minimize the harmonic distortions caused by SCR type converter drive systems. The overload current limit rating is 150% for 1 min. every 10 min. The following features are included: Two - two door, modified Nema 12 cabinets, Mild steel construction measuring (90"x78"x30"). Paint is factory standard, ANSI 61 Gray. 35

36 Two Amp. Molded Case Switches mounted w/ through the door manual switch handle (pad lockable). Two ADC 1-Quadrant SCR bridge assemblies. Two Sets - SCR AC line fusing. Two - cabinet air cooling and filtration packages. Two - Siemens High HP command modules. One - 85 ADC/single phase, Siemens field module and transformer. Customer supplied encoder feedback speed control as per customer drawings. One main motor blower circuit V Max. Three digital meters for the following: Armature Amps, Armature Volts and Field Amps. Meters are mounted in the Master drive cabinet door. Siemens door mounted programming and fault indication keypad. Door mounted Hand/Off/Auto selector switch. Copper pad bus areas for incoming and out going AC/DC power connections. DCS 400 Digital DC Converter 20 to 1000A DC Introducing the world's most competitive DC package 36

37 ABB has developed a user-friendly drive system package (DCS 400, DMI Motor) to meet the demands of machine builders. Our aim is to offer the best combination of reliable products at the most affordable price, backed by on-time delivery, good partnership and fast response to inquiries. At the heart of the drive package is the DCS a new generation of DC drives specifically designed to meet the ever-changing needs of machine builders. "Total ease of use" was the foundation of this drive's development. The result is a drive that is: as easy to handle as an analog drive yet incorporates all of the features of a digital drive. easy to design into machine equipment, with just the right amount of features. easy to install and set-up, even by those without special drives experience. Small Design The DCS 400's compact design brings substantial space savings to machine builders, allowing them to integrate more accessories within the same space. Existing DC drives are easily replaced with the DCS 400. At only in (270 mm) wide, and with all the power cabling located at the base of the drive rather than the side, two DCS 400 units can be installed inside the Technical Features Digital 6-pulse converter Hp ( kw) 20 to 1000 A DC Input Voltage from 230 to 500 V, 50/60 Hz Nonregenerative & regenerative drives available IGBT - field supply for field weakening is included Supply Voltages Power and VAC, 3- Field: phase Input Hz Frequency: Converter Fan: 115/230 VAC, singlephase Control 115/230 VAC, singlephase Power: Control I/O Digital Inputs: Eight (8), 24 VDC Digital Four (4), 24 VDC Outputs: One (1) relay Analog Inputs: Two (2), ±10 VDC, 12 bit Analog Two (2), ±10 VDC, 12 Outputs: bit Power Spectrum, 2Q, Non- Regenerative Module Type Armature Current Range (A) Field Current (A) kw HP 20, 45, 65, 12 to 10 to A1 0.1 to 6 90, A2 180, to 104 to 100 to 37

38 same in (600 mm) cabinet. The field supply, including the fuse and choke, are integrated into the DCS 400, further contributing to its small size and simplicity of design. No need for a field voltage adaptation transformer to match the line supply voltage with that of the motor. The DCS 400 uses fewer components, leading to both smaller size and greater reliability. A3 A4 315, 405, , 740, to 183 to 175 to to 354 to 350 to Power Spectrum, 4Q, Regenerative Module Type A1 Armature Current Range (A) 25, 50, 75, 100, 140 A2 200, 260 A3 A4 350, 450, , 820, 1000 Field Current (A) kw HP 13 to 10 to 0.1 to to 104 to 100 to to 182 to 200 to to 354 to 400 to Fieldbus Adapters Multiple serial communication options allow integration with higher level control systems. The total integrated package for machine builders DC Converters DCS pulse converters offer accurate torque and speed control in the low power range. Simplicity of operation is a hallmark of the drive. DC Motors ABB's family of DC motors offer a compact, modular design, combined with low vibration and noise levels as well as high output and energy efficiency. Speed Feedback A variety of speed feedback devices can be used with PowerPack and are standard features of the DCS

39 The user is guided through the commissioning procedure by following simple steps that are outlined by the alpha-numeric control panel. An alternative to the control panel is ABB's PC-based program, Drive Window Light, used for guided on-line commissioning, including: Parameter setting Reference display and feedback values Trending On-line help files 39

40 The easiest drive to install... (b) Reduced Wiring By fully integrating the field supply, ABB's engineers have been able to patent a design with three wires in and four wires out, reducing wiring and requiring less installation time. Fast and Easy Installation ABB's DCS 400 cuts costs and installation time by incorporating the following features: A simple, step-by-step installation guide Bottom plate cable entry, providing rapid and easy access to power terminals Easy to access I/O connection points via bottom cover plate The drive's ability to operate directly on any worldwide voltage from V, 50/60 Hz main, V aux. 40

41 The fastest drive to commission... (c) Commissioning Wizard The DCS 400 is the first digital drive which can be commissioned without special knowledge of drives. More importantly, the commissioning and start-up time is dramatically faster than that of other DC drives. The wizard uses either the drive's control panel or ABB's commissioning tool, Drive Window Light, which is based on RS232 communications using a standard plug (see illustration above). Once the motor and process data have been entered into the drive, the user is guided through commissioning using the self-tuning functions for armature current, speed, flux and field current. No additional documentation or hardware is needed to commission the DCS 400. Application macros that require setting only a few user-selectable parameters make the commissioning of specific applications easier compared to the several hundred parameters that must be set with other DC drives. Module Type A1 A2 A3 Height in (mm) 12-1/2 (310) 12-1/2 (310) 15-3/4 (400) A4 23 (580) Depth in (mm) 8 (200) 10-3/4 (270) 12-1/2 (310) 13-3/4 (345) Width in (mm) 10-3/4 (270) 10-3/4 (270) 10-3/4 (270) 10-3/4 (270) 41

42 4.0 RECOMMENDATIONS A new generation of variable speed drives: The Hanover Messe saw the launch of the new generation of Emotron AB variable speed drives, which have grown in terms of function but reduced in size, with a new application focus The Hannover Messe saw the launch of the new generation of Emotron AB variable speed drives, which have grown in terms of function but reduced in size. At the same time the company presented its new strategy of focusing on selected applications. This allows cutting edge knowledge and products adapted to specific needs. The new Emotron FDU is developed for applications such as pumps, fans, compressors and blowers, while Emotron VFX is adapted for dynamic applications such as cranes, crushers and mixers. Increased functionality in a smaller format. The Emotron new variable speed drives, FDU and VFX in the ,500 kw output range, offer efficient, reliable and user-friendly control. Among the new features are. * An integrated shaft power monitor that detects deviations from normal operation over the whole speed range. This prevents unplanned downtime and allows preventive action before energy is lost or equipment damaged. * New compact I/O boards allow connection of up to four options, for example communication, pump control and crane control. Virtual connection of logic functions, comparators and timers means that more options can be used. Different logical functions can be combined without cables or external I/Os. * Integrated temperature control offers more efficient motor protection and extends equipment lifetime. PTC and PT100 sensors can be connected for motor protection and process feedback without transmitters. 42

43 Encoder can be connected for more accurate speed control in dynamic applications. * Operating parameters are set in selectable process units, which make monitoring simpler and safer. The control panel is removable and can easily be moved between variable speed drives to copy settings. * The installation is simple and cost effective due to IP54 enclosure and extremely compact format even for high outputs. Liquid cooling is available as an option, which saves space and energy because air conditioning is not required. 43

44 5.0 CONCLUSIONS DC drives consist of an SCR (Silicon Controlled Rectifier) bridge, which converts incoming three or singlephase AC volts to DC volts. During this conversion process DC drives then can regulate speed, torque, voltage and current conditions of the DC motor. This is ideal for industrial processes such as tube mills, extruders, mixers, paper machines and various other controlled applications. Joliet Technologies can provide several DC Drives from different reputable manufactures. Packages can vary from Onsite Retrofits to custom multi drive cabinets. 44

Baldor Motor Basics Part 11

Baldor Motor Basics Part 11 Baldor Motor Basics Part 11 Explosion-Proof Motors in Division 2 Areas and DC Drive Fundamentals Edward Cowern, P.E. We have found that one of the most confusing things about explosion-proof requirements

More information

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL 3.1 Introduction Almost every mechanical movement that we see around us is accomplished by an electric motor. Electric machines are a means of converting

More information

CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS

CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS Objective Describe the necessary conditions for motor and generator operation. Calculate the force on a conductor carrying current in the presence of the

More information

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors 1. What are the two main parts of a three-phase motor? Stator and Rotor 2. Which part of a three-phase squirrel-cage induction motor is a

More information

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS MANTECH ELECTRONICS Stepper Motors Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS TYPES OF STEPPING MOTORS 1. VARIABLE RELUCTANCE 2. PERMANENT MAGNET 3. HYBRID MOTOR WINDINGS

More information

UNIT I D.C. MACHINES PART A. 3. What are factors on which hysteresis loss? It depends on magnetic flux density, frequency & volume of the material.

UNIT I D.C. MACHINES PART A. 3. What are factors on which hysteresis loss? It depends on magnetic flux density, frequency & volume of the material. EE6352-ELECTRICAL ENGINEERING AND INSTRUMENTATION UNIT I D.C. MACHINES PART A 1. What is prime mover? The basic source of mechanical power which drives the armature of the generator is called prime mover.

More information

AC Motors vs DC Motors. DC Motors. DC Motor Classification ... Prof. Dr. M. Zahurul Haq

AC Motors vs DC Motors. DC Motors. DC Motor Classification ... Prof. Dr. M. Zahurul Haq AC Motors vs DC Motors DC Motors Prof. Dr. M. Zahurul Haq http://teacher.buet.ac.bd/zahurul/ Department of Mechanical Engineering Bangladesh University of Engineering & Technology ME 6401: Advanced Mechatronics

More information

INTRODUCTION Principle

INTRODUCTION Principle DC Generators INTRODUCTION A generator is a machine that converts mechanical energy into electrical energy by using the principle of magnetic induction. Principle Whenever a conductor is moved within a

More information

UNIT 2. INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES. General Objective

UNIT 2. INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES. General Objective DC GENERATOR (Part 1) E2063/ Unit 2/ 1 UNIT 2 INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES General Objective : To apply the basic principle of DC generator, construction principle and types of DC generator.

More information

BELT-DRIVEN ALTERNATORS

BELT-DRIVEN ALTERNATORS CHAPTER 13 BELT-DRIVEN ALTERNATORS INTRODUCTION A generator is a machine that converts mechanical energy into electrical energy using the principle of magnetic induction. This principle is based on the

More information

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

1/6 through 5 HP Adjustable Speed, DC Motor Controllers 1/6 through 5 HP Adjustable Speed, DC Motor Controllers 1/6-5 HP 115 or 230 V, Single Phase - Reconnectable Four Quadrant Regenerative Selectable Deadband AC Line Starting DC Tachometer Feedback Run Contact

More information

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual Electronic Motor Brake Type G Instructions and Setup Manual Table of Contents Table of Contents Electronic Motor Brake Type G... 1 1. INTRODUCTION... 2 2. DESCRIPTION AND APPLICATIONS... 2 3. SAFETY NOTES...

More information

Principles of Electrical Engineering

Principles of Electrical Engineering D.C GENERATORS Principle of operation of D.C machines, types of D.C Generators, e.m.f equation of D.C Generator, O.C.C of a D.C Shunt Generator, Load characteristics of D.C.Generators GENERATOR PRINCIPLE:

More information

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION 1. What is meant by drive and electric drive? Machines employed for motion control are called drives and may employ any one of the prime movers for

More information

EE6352-ELECTRICAL ENGINEERING AND INSTRUMENTATION UNIT I D.C. MACHINES PART A

EE6352-ELECTRICAL ENGINEERING AND INSTRUMENTATION UNIT I D.C. MACHINES PART A EE6352-ELECTRICAL ENGINEERING AND INSTRUMENTATION 1. What is prime mover? UNIT I D.C. MACHINES PART A The basic source of mechanical power which drives the armature of the generator is called prime mover.

More information

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2 RCP200 Series Motor Controls Instruction Manual Model RCP202-000 Model RCP205-000 Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2 You ve just purchased the best! Congratulations! You ve just purchased

More information

Historical Development

Historical Development TOPIC 3 DC MACHINES DC Machines 2 Historical Development Direct current (DC) motor is one of the first machines devised to convert electrical power into mechanical power. Its origin can be traced to the

More information

DC Motor and Generator Theory By

DC Motor and Generator Theory By DC Principles Study Unit DC Motor and Generator Theory By Robert Cecci iii Preview DC motors and generators are widely used in industrial applications. Both motors and generators are devices that produce

More information

2006 MINI Cooper S GENINFO Starting - Overview - MINI

2006 MINI Cooper S GENINFO Starting - Overview - MINI MINI STARTING SYSTEM * PLEASE READ THIS FIRST * 2002-07 GENINFO Starting - Overview - MINI For information on starter removal and installation, see the following articles. For Cooper, see STARTER WITH

More information

Electrical Machines-I (EE-241) For S.E (EE)

Electrical Machines-I (EE-241) For S.E (EE) PRACTICAL WORK BOOK For Academic Session 2013 Electrical Machines-I (EE-241) For S.E (EE) Name: Roll Number: Class: Batch: Department : Semester/Term: NED University of Engineer ing & Technology Electrical

More information

MaxPak Plus Analog DC V S Drive

MaxPak Plus Analog DC V S Drive Three-Phase 3-600 HP non-regenerative and 5-150 HP regenerative drives Designed to accommodate a wide range of industrial requirements, the DC V S Drive has been widely applied worldwide. Selected ratings

More information

Application Note CTAN #127

Application Note CTAN #127 Application Note CTAN #127 Guidelines and Considerations for Common Bus Connection of AC Drives An important advantage of AC drives with a fixed DC is the ability to connect the es together so that energy

More information

2. Draw the speed-torque characteristics of dc shunt motor and series motor. (May2013) (May 2014)

2. Draw the speed-torque characteristics of dc shunt motor and series motor. (May2013) (May 2014) UNIT 2 - DRIVE MOTOR CHARACTERISTICS PART A 1. What is meant by mechanical characteristics? A curve is drawn between speed-torque. This characteristic is called mechanical characteristics. 2. Draw the

More information

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved DRM TM DRM-HP TM Electronic Dynamo Regulator INSTRUCTION MANUAL COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved INTRODUCTION The Clover Systems DRM is a state-of-the art all-electronic voltage and current

More information

CONTROL FEATURES AVAILABLE OPTIONS

CONTROL FEATURES AVAILABLE OPTIONS Vari Speed A2000 TABLE OF CONTENTS Control Features Options Application Data Operating Condition s Control Ratings Chart Mounting Dimensions Installation and Wiring Typical Wiring Diagram Schematic (Block

More information

Temperature Controllers

Temperature Controllers Controllers SCR Power Controllers Introduction to Silicon Controlled Rectifier (SCR) Power Controllers Features and Benefits of SCRs High reliability Because the SCR power controller is a solid-state device,

More information

Temperature Controllers

Temperature Controllers SCR Power Controllers Introduction to Silicon Controlled Rectifier (SCR) Power Controllers Features and Benefits of SCRs High reliability Because the SCR power controller is a solid-state device, it provides

More information

DC Series Motors by Thomas E. Kissell Industrial Electronics, Second Edition, Prentice Hall PTR

DC Series Motors by Thomas E. Kissell Industrial Electronics, Second Edition, Prentice Hall PTR Site Help Search NI Developer Zone DC Series Motors by Thomas E. Kissell Industrial Electronics, Second Edition, Prentice Hall PTR Back to Document Table of Contents: Series Motor Diagram Series Motor

More information

Note 8. Electric Actuators

Note 8. Electric Actuators Note 8 Electric Actuators Department of Mechanical Engineering, University Of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada 1 1. Introduction In a typical closed-loop, or feedback, control

More information

three different ways, so it is important to be aware of how flow is to be specified

three different ways, so it is important to be aware of how flow is to be specified Flow-control valves Flow-control valves include simple s to sophisticated closed-loop electrohydraulic valves that automatically adjust to variations in pressure and temperature. The purpose of flow control

More information

QUASAR KIT No THYRISTOR - TRIAC TESTER

QUASAR KIT No THYRISTOR - TRIAC TESTER QUASAR KIT No. 1087 THYRISTOR - TRIAC TESTER GENERAL DESCRIPTION With this new kit Quasar Kit offers you a very useful instrument for your bench that will help you to test THYRISTORS and TRIACS. These

More information

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date: CSDA Best Practice Title: Hi-Cycle Concrete Cutting Equipment Issue No: CSDA-BP-010 : Oct 1, 2010 Revised : Introduction Hi-cycle/high frequency concrete cutting equipment has become more prevalent in

More information

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN Form 1254 BRAKETRON Electronic Motor Brake Instructions SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN TABLE OF CONTENTS SECTION TITLE PAGE I. Introduction 1 II. Specifications 1 III. Principles

More information

PI Electrical Equipment - Course PI 30.2 MOTORS

PI Electrical Equipment - Course PI 30.2 MOTORS Electrical Equipment - Course PI 30.2 MOTORS OBJECTIVES On completion of this module the student will be able to: 1. Briefly explain, in writing, "shaft rotation" as an interaction of stator and rotor

More information

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible DC Drives Flexible & Powerful single-phase DC drives provide a complete family solution from the compact Series 2120 chassis drive to the powerful Series 2230 and it s feature rich application specific

More information

2014 ELECTRICAL TECHNOLOGY

2014 ELECTRICAL TECHNOLOGY SET - 1 II B. Tech I Semester Regular Examinations, March 2014 ELECTRICAL TECHNOLOGY (Com. to ECE, EIE, BME) Time: 3 hours Max. Marks: 75 Answer any FIVE Questions All Questions carry Equal Marks ~~~~~~~~~~~~~~~~~~~~~~~~~~

More information

Introduction to Closed-Loop Control Overview

Introduction to Closed-Loop Control Overview CLC1 Introduction to Closed-Loop Control Overview DC Motor Drive - Simplified Block Diagram Speed Set Point (Reference) PS Com + Summing Point PS Com + Gain Operational Amplifier Error Signal Firing Circuit

More information

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved DRM TM DRM-HP TM Electronic Dynamo Regulator INSTRUCTION MANUAL COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved INTRODUCTION The Clover Systems DRM is a state-of-the art all-electronic voltage and current

More information

INDUCTANCE FM CHAPTER 6

INDUCTANCE FM CHAPTER 6 CHAPTER 6 INDUCTANCE INTRODUCTION The study of inductance is a very challenging but rewarding segment of electricity. It is challenging because at first it seems that new concepts are being introduced.

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

ANTI-LOCK BRAKES. Section 9. Fundamental ABS Systems. ABS System Diagram

ANTI-LOCK BRAKES. Section 9. Fundamental ABS Systems. ABS System Diagram ANTI-LOCK BRAKES Fundamental ABS Systems Toyota Antilock Brake Systems (ABS) are integrated with the conventional braking system. They use a computer controlled actuator unit, between the brake master

More information

SERVICE SHOP NOTES. Use ohmmeter to check the resistance between the leads.

SERVICE SHOP NOTES. Use ohmmeter to check the resistance between the leads. SERVICE SHOP NOTES LIMA MAC SELF VOLTAGE REGULATED GENERATORS Troubleshooting Tips Symptom: Engine bogs down or stalls even at no load. Problem: Main stator has one or more taps wound or connected incorrectly.

More information

Fincor Series 2230 MKII/2240

Fincor Series 2230 MKII/2240 Fincor Series 2230 MKII/ Fincor Series 2200 regenerative drives are ideal for your more demanding applications. They feature flexibility with ratings up to 5 horsepower. The Series 2230 MKII offers new

More information

AIR COOLED RECTIFIER SPECIFICATION S-50-A

AIR COOLED RECTIFIER SPECIFICATION S-50-A SPECIFICATIONS AIR COOLED RECTIFIER Spec50a1 5JAN1999 SPECIFICATION S-50-A HIGH VOLTAGE SINGLE TRANSFORMER AIR COOLED RECTIFIER Standard output power range: 250 to 600 volts at 100 to 1,200 amperes TECHNICAL

More information

Introduction: Electromagnetism:

Introduction: Electromagnetism: This model of both an AC and DC electric motor is easy to assemble and disassemble. The model can also be used to demonstrate both permanent and electromagnetic motors. Everything comes packed in its own

More information

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Chapter 8 Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Article 430 of the NEC covers application and installation of

More information

Question 2: Around the bar magnet draw its magnetic fields. Answer:

Question 2: Around the bar magnet draw its magnetic fields. Answer: Chapter 13: Magnetic Effects of Electric Current Question 1: What is the reason behind the compass needle is deflected when it is brought close to the bar magnet? Compass needles work as a small bar magnet;

More information

DC MOTORS DC Motors DC Motor is a Machine which converts Electrical energy into Mechanical energy. Dc motors are used in steel plants, paper mills, textile mills, cranes, printing presses, Electrical locomotives

More information

Lower-Loss Technology

Lower-Loss Technology Lower-Loss Technology FOR A STEPPING MOTOR Yasuo Sato (From the Fall 28 Technical Conference of the SMMA. Reprinted with permission of the Small Motor & Motion Association.) Management Summary The demand

More information

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER XXXX H02 GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER XXXX CONTROL OR REGULATION OF ELECTRIC MOTORS, GENERATORS, OR DYNAMO-ELECTRIC CONVERTERS; CONTROLLING TRANSFORMERS, REACTORS OR CHOKE

More information

Model 2500 Horsepower Computer System User Manual

Model 2500 Horsepower Computer System User Manual Model 2500 Horsepower Computer System User Manual Manufacturered by: Ries Labs, Inc. 2275 Raven Road Farina, IL 62838 Phone: (618) 238-1400 email: admin@rieslabs.com Table of Contents Description ----------------------------------------------------------------

More information

ELECTRICAL MAINTENANCE

ELECTRICAL MAINTENANCE ELECTRICAL MAINTENANCE II PRACTICAL JOURNAL DATA 1 EXPERIMENT NO. 1 AIM: TO FIND VOLTAGE RATIO OF A GIVEN TRANSFORMER. CIRCUIT DIAGRAM: OBSERVATION TABLE: Sr.No. 1 2 3 4 Primary Voltage (V 1 ) Secondary

More information

Principles of iers (intelligent

Principles of iers (intelligent Principles of iers (intelligent Energy Recovery System) Chapter 4 Table of Contents............... 4 1 Principles of the iers....................................... 4 2 Enabling Intelligent Energy Recovery

More information

Ch 4 Motor Control Devices

Ch 4 Motor Control Devices Ch 4 Motor Control Devices Part 1 Manually Operated Switches 1. List three examples of primary motor control devices. (P 66) Answer: Motor contactor, starter, and controller or anything that control the

More information

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601) Instruction and Operation Manual valid for art.-no.: 10091 F-TA-05/C-ISO (start at modification No. 1601) valid for art.-no.: 10092 F-TA-05/C-Sh (start at modification No. 1601) CAUTION: As with any form

More information

1. Anti-lock Brake System (ABS)

1. Anti-lock Brake System (ABS) W1860BE.book Page 2 Tuesday, January 28, 2003 11:01 PM 1. Anti-lock Brake System () A: FEATURE The 5.3i type used in the Impreza has a hydraulic control unit, an control module, a valve relay and a motor

More information

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual Graham TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual Vari Speed S1000 Instruction Manual TABLE OF CONTENTS Introduction 4 Unit Features 5 Operating Conditions 6 Specifications 7 Ratings

More information

Step Motor Lower-Loss Technology An Update

Step Motor Lower-Loss Technology An Update Step Motor Lower-Loss Technology An Update Yatsuo Sato, Oriental Motor Management Summary The demand for stepping motors with high efficiency and low losses has been increasing right along with the existing

More information

Electric Motor Controls BOMA Pre-Quiz

Electric Motor Controls BOMA Pre-Quiz Electric Motor Controls BOMA Pre-Quiz Name: 1. How does a U.P.S. (uninterruptable power supply) work? A. AC rectified to DC batteries then inverted to AC B. Batteries generate DC power C. Generator, batteries,

More information

Application Note : Comparative Motor Technologies

Application Note : Comparative Motor Technologies Application Note : Comparative Motor Technologies Air Motor and Cylinders Air Actuators use compressed air to move a piston for linear motion or turn a turbine for rotary motion. Responsiveness, speed

More information

About this Troubleshooting Document

About this Troubleshooting Document About this Troubleshooting Document This document lists the error codes that exist within the Precor software hierarchy. Each section will include a description of the error code being displayed and the

More information

Today s lecture: Generators Eddy Currents Self Inductance Energy Stored in a Magnetic Field

Today s lecture: Generators Eddy Currents Self Inductance Energy Stored in a Magnetic Field PHYSICS 1B Today s lecture: Generators Eddy Currents Self Inductance Energy Stored in a Magnetic Field PHYSICS 1B Lenz's Law Generators Electric generators take in energy by work and transfer it out by

More information

A Practical Guide to Free Energy Devices

A Practical Guide to Free Energy Devices A Practical Guide to Free Energy Devices Part PatD20: Last updated: 26th September 2006 Author: Patrick J. Kelly This patent covers a device which is claimed to have a greater output power than the input

More information

Single-Phase AC Induction Squirrel Cage Motors. Permanent Magnet Series Wound Shunt Wound Compound Wound Squirrel Cage. Induction.

Single-Phase AC Induction Squirrel Cage Motors. Permanent Magnet Series Wound Shunt Wound Compound Wound Squirrel Cage. Induction. FAN ENGINEERING Information and Recommendations for the Engineer Twin City Fan FE-1100 Single-Phase AC Induction Squirrel Cage Motors Introduction It is with the electric motor where a method of converting

More information

A6Z OPERATING MANUAL

A6Z OPERATING MANUAL A6Z OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty.p.

More information

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR Velimir Nedic Thomas A. Lipo Wisconsin Power Electronic Research Center University of Wisconsin Madison

More information

Experiment 3. The Direct Current Motor Part II OBJECTIVE. To locate the neutral brush position. To learn the basic motor wiring connections.

Experiment 3. The Direct Current Motor Part II OBJECTIVE. To locate the neutral brush position. To learn the basic motor wiring connections. Experiment 3 The Direct Current Motor Part II OBJECTIVE To locate the neutral brush position. To learn the basic motor wiring connections. To observe the operating characteristics of series and shunt connected

More information

IT 318 SUPPLEMENTARY MATERIAL CHAPTER 4

IT 318 SUPPLEMENTARY MATERIAL CHAPTER 4 IT 318 SUPPLEMENTARY MATERIAL CHAPTER 4 Electric Motors V. 2013 BARRY M. LUNT Brigham Young University Table of Contents Chapter 4: Electric Motors... 2 Overview... 2 4-1 Commutation... 2 4-2 Stepper Motors...

More information

ELEN 236 DC Motors 1 DC Motors

ELEN 236 DC Motors 1 DC Motors ELEN 236 DC Motors 1 DC Motors Pictures source: http://hyperphysics.phy-astr.gsu.edu/hbase/magnetic/mothow.html#c1 1 2 3 Some DC Motor Terms: 1. rotor: The movable part of the DC motor 2. armature: The

More information

ECET 211 Electric Machines & Controls Lecture 5-1 Electric Motors. Lecture 5-1 Electric Motors

ECET 211 Electric Machines & Controls Lecture 5-1 Electric Motors. Lecture 5-1 Electric Motors ECET 211 Electric Machines & Controls Lecture 5-1 Electric Motors (1 of 4) Text Book: Chapter 5 Electric Motors, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015.

More information

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines Department of Electrical Engineering Lecture Introduction to Electrical Machines 1 In this Lecture Induction motors and synchronous machines are introduced Production of rotating magnetic field Three-phase

More information

Step Motor. Mechatronics Device Report Yisheng Zhang 04/02/03. What Is A Step Motor?

Step Motor. Mechatronics Device Report Yisheng Zhang 04/02/03. What Is A Step Motor? Step Motor What is a Step Motor? How Do They Work? Basic Types: Variable Reluctance, Permanent Magnet, Hybrid Where Are They Used? How Are They Controlled? How To Select A Step Motor and Driver Types of

More information

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved DR310 TM Electronic Dynamo Regulator INSTRUCTION MANUAL COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved INTRODUCTION The Clover Systems DR310 is an allelectronic voltage and current regulator for dynamos

More information

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc.

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR CLASSIFICATION. 2010, The McGraw-Hill Companies, Inc. Chapter 2 MOTOR CLASSIFICATION 1 In general, motors are classified according to the type of power used (AC or DC) and the motor's principle of operation. AC DC Motor Family Tree 2 DC MOTOR CONNECTIONS

More information

A Practical Guide to Free Energy Devices

A Practical Guide to Free Energy Devices A Practical Guide to Free Energy Devices Part PatD11: Last updated: 3rd February 2006 Author: Patrick J. Kelly Electrical power is frequently generated by spinning the shaft of a generator which has some

More information

ALTERNATOR - CHRYSLER 40/90-AMP & 50/120 AMP

ALTERNATOR - CHRYSLER 40/90-AMP & 50/120 AMP ALTERNATOR - CHRYSLER 40/90-AMP & 50/120 AMP 1988 Chrysler LeBaron Convert/Coupe 1988 ELECTRICAL Chrysler Motors 40/90 & 50/120 Amp Alternators FWD Models DESCRIPTION The charging system consists of an

More information

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR TECHNICAL MANUAL MODEL DVR 2000 AND DVR 2000C FIGURE 1 - FRONT AND REAR VIEW OF VOLTAGE REGULATOR...4 SECTION 1- INTRODUCTION...5 GENERAL DESCRIPTION...5 SPECIFICATIONS...5

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012 SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

Synchronous Motor Drives

Synchronous Motor Drives UNIT V SYNCHRONOUS MOTOR DRIVES 5.1 Introduction Synchronous motor is an AC motor which rotates at synchronous speed at all loads. Construction of the stator of synchronous motor is similar to the stator

More information

Pre-lab Questions: Please review chapters 19 and 20 of your textbook

Pre-lab Questions: Please review chapters 19 and 20 of your textbook Introduction Magnetism and electricity are closely related. Moving charges make magnetic fields. Wires carrying electrical current in a part of space where there is a magnetic field experience a force.

More information

Application Notes. Calculating Mechanical Power Requirements. P rot = T x W

Application Notes. Calculating Mechanical Power Requirements. P rot = T x W Application Notes Motor Calculations Calculating Mechanical Power Requirements Torque - Speed Curves Numerical Calculation Sample Calculation Thermal Calculations Motor Data Sheet Analysis Search Site

More information

The Effect of DC Machine Adjustment on Loop Unbalance

The Effect of DC Machine Adjustment on Loop Unbalance The Effect of DC Machine Adjustment on Loop Unbalance WMEA, Edmonton, Alberta, Canada June 11-13, 13, 2008 Rich Hall Morgan AM&T Jim Shackelford Peabody Energy Technical Contributor Jason Conrad GE Canada

More information

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number: INSTRUCTION MANUAL FOR VOLTAGE REGULATOR Model: APR 125-5 Part Number: 9 1688 00 100 Publication Number: 9 1688 00 990 Revision H: 07/2001 CONTENTS SECTION 1 GENERAL INFORMATION...1-1 DESCRIPTION... 1-1

More information

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad - 500 043 MECHANICAL ENGINEERING ASSIGNMENT Name : Electrical and Electronics Engineering Code : A40203 Class : II B. Tech I Semester Branch :

More information

Features IN THIS CHAPTER

Features IN THIS CHAPTER CHAPTER THREE 3Special Features IN THIS CHAPTER Motor Braking Regeneration Solutions Sharing the Power Bus: V Bus+ and V Bus- Current Foldback (I T Limit) Front Panel Test Points Resolver Alignment ➂ Special

More information

1 THE WOLVERTON SYSTEM OF TRAIN LIGHTING.

1 THE WOLVERTON SYSTEM OF TRAIN LIGHTING. 1 THE WOLVERTON SYSTEM OF TRAIN LIGHTING. The Wolverton equipment is a single battery system utilising a plain shunt wound dynamo. The dynamo is controlled by an automatic field regulator which senses

More information

MAGNETIC EFFECTS OF ELECTRIC CURRENT

MAGNETIC EFFECTS OF ELECTRIC CURRENT MAGNETIC EFFECTS OF ELECTRIC CURRENT It is observed that when a compass is brought near a current carrying conductor the needle of compass gets deflected because of flow of electricity. This shows that

More information

Technical Explanation for Inverters

Technical Explanation for Inverters CSM_Inverter_TG_E_1_2 Introduction What Is an Inverter? An inverter controls the frequency of power supplied to an AC motor to control the rotation speed of the motor. Without an inverter, the AC motor

More information

A3Z OPERATING MANUAL

A3Z OPERATING MANUAL A3Z OPERATING MANUAL TABLE OF CONTENTS Introduction... p. 2 Features... p. 2 Description... p. 3 Theory of Operation... p. 3 Installation... p. 4 Electrical Connections... p. 5 Options... p. 6 Warranty...

More information

SPH3U UNIVERSITY PHYSICS

SPH3U UNIVERSITY PHYSICS SPH3U UNIVERSITY PHYSICS ELECTRICITY & MAGNETISM L (P.599-604) The large-scale production of electrical energy that we have today is possible because of electromagnetic induction. The electric generator,

More information

ALTERNATOR - BOSCH 35/75-AMP & 40/90-AMP

ALTERNATOR - BOSCH 35/75-AMP & 40/90-AMP ALTERNATOR - BOSCH 35/75-AMP & 40/90-AMP 1988 Chrysler LeBaron Convert/Coupe 1988 ALTERNATORS & REGULATORS Chrysler Motors - Bosch 35/75 & 40/90 Amp Alternator All Models DESCRIPTION The charging system

More information

DIVISION 7 GENERATORS AND MOTORS

DIVISION 7 GENERATORS AND MOTORS DIVISION 7 GENERATORS AND MOTORS Principles, Characteristics, and Management of DC Generators (Dynamos).................................... 7.1 Principles, Characteristics, and Management of AC Generators

More information

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED 1. ENCLOSURE REQUIRED If the OC1 control is furnished as an open-chassis unit (standard), mount control in an enclosure 12 x 10 x 5 or larger and mount enclosure where room temperature does not exceed

More information

Electrical Machines -II

Electrical Machines -II Objective Type Questions: 1. Basically induction machine was invented by (a) Thomas Alva Edison (b) Fleming (c) Nikola Tesla (d) Michel Faraday Electrical Machines -II 2. What will be the amplitude and

More information

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS TJ STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS page DESCRIPTION AND OPERATION STARTER MOTOR... 2 STARTER RELAY... 3 STARTING SYSTEM... 1 DIAGNOSIS AND TESTING STARTER MOTOR... 8 STARTER MOTOR NOISE

More information

Application Information

Application Information Moog Components Group manufactures a comprehensive line of brush-type and brushless motors, as well as brushless controllers. The purpose of this document is to provide a guide for the selection and application

More information

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR 33 CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR 3.1 INTRODUCTION This chapter presents the design of frameless Limited Angle Brushless Torque motor. The armature is wound with toroidal

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

Exhaust System Bypass Valves and Exhaust Valve Bypass Controller

Exhaust System Bypass Valves and Exhaust Valve Bypass Controller Exhaust System Bypass Valves and Exhaust Valve Bypass Controller Basic Primer on Exhaust System Flow Velocity and Backpressure The information about exhaust system theory was obtained from research on

More information

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / / Non-Regen Drives Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor.

More information