USER MANUAL DCA15. Auto Aır Conditioner Controller Unit. Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17

Size: px
Start display at page:

Download "USER MANUAL DCA15. Auto Aır Conditioner Controller Unit. Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17"

Transcription

1 USER MANUAL DCA15 Auto Aır Conditioner Controller Unit Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17

2 INDEX 1) GENERAL DESCRIPTION 2) BEFORE USING THE DEVİCE 3) SAFETY PRECAUTIONS 4) INSTALLATION AND MOUNTING 5) ELECTRICAL CONNECTION 6) TEMPERATURE CONTROL 7) KEYS FUNCTION 8) PARAMETERS 9) SPECIFICATIONS

3 1-) GENERAL DESCRIPTION DCA15 is a Air Conditioner controller unit for vehicles and after-market automotive applications. The controller unit has three steps fan output, one A/C output and one flap output. A/C set temperature can be adjusted in parameters menu. Fans, flap and A/C can be turned on by front panel buttons.. 2-) BEFORE USING THE DEVICE This manual should be kept near the device and should be paid attention to the instructions for easy and quick reference. This device shall not be used for purposes different from those described hereunder. It cannot be used as a safety device. Check application limits before using the device. 3-) SAFETY PRECAUTIONS Check the supply voltage correct, before connecting the device. Do not expose the device to water or moisture. Use the device only within the operating limits avoiding sudden temperature changes with atmospheric humidity to prevent formation of condensation. Warning: Disconnect any electrical connections before any kind of maintanance The probes should be mounted upwards due to casual liquid infiltration. Device plastic case should never be opened. In case of failure or faulty operation, please send the device to the distributor with detailed description of fault. Consider the maximum current which can be applied to each relay (See Specifications). Ensure that the wires for probes, loads and the power supply are seperated and far enough from each other, without crossing and intertwining. In case of applications in industrial environments, the use of mains filter in parallel with inductive loads would be useful.

4 4-) INSTALLATION AND MOUNTING The device should be mounted on vertical panel in a 29mm x 71mm panel cut and fixed using the special bracket supplied. Avoid places subject to strong vibrations, corrosive gases, excessive dirt or humidity.

5 5-) ELECTRICAL CONNECTION The device is provided with screw terminal block to connect cables with a cross section up to 2,5mm 2. Before connecting cables, make sure the power supply complies with the device s requirements. Do not exceed the maximum current allowed on the relay and in case of heavier loads use a suitable external relay. The probes should be mounted upwards due to casual liquid infiltration. It is recommended to place the thermostat probe away from air streams to correctly measure the average room temperature. Place the defrost termination probe among the evaporator fins, in the coldest place, where the most ice is formed, far from heaters or from the warmest place during defrost, to prevent premature defrost termination.

6 6-) TEMPERATURE CONTROL Temperature control method is ON/OFF control with hysteresis: if the temperature measured goes below SET value the compressor is turned off, and then when the temperature measured reaches the value SET plus r0 (hysteresis - differential) the compressor is started again.

7 . 7-) KEY FUNCTIONS A/C : Turns on and off A/C. If A/C is ON, Fan1 is always ON. A/C SET temperature can be adjusted in parameters menu. A/C SET temperature is controlled dependind on internal temperature. FAN: Steps up fan stage with each press, in turn of (if A/C is ON) or (if A/C is OFF). At the first Fan stage, only one Fan LED lits. At the second Fan stage, two FAN LEDs lit. At the third Fan stage, three Fan LEDs lit. EXT: FLAP: UP: If pressed, the external temperature can be displayed for 3 seconds. Turns on and off FLAP output, with each press. Increments parameters value DOWN: Decrements parameters value 8-) PARAMETERS PARAMETERS: Par.: St Internal Temperature SET Value Description: Range: Default: Lo up HY Minimum working SET value Low limit value for SET value change. Maximum working SET value. Up limit value for SET value change. Temperature differantial between Compressor turn on and turn off. (Hysteresis - Differantial) Compressor will cut out at SET value and will cut in again at SET value + r0 (Hysteresis Differantial) Reset to Factory Defaults -40,0 o C ~ 150,0 o C -40, 0 o C -40,0 o C ~ 150,0 o C 150,0 o C 0,1 ~ 20,0 2,0 rfac If this parameter is changed to 1 and exited from menü, all parameters changed to factory default values and saved. This way, in case of 0: No 1: Yes 0 parameter conflict, you can change parameters from the factory default values.

8 DCA15 DCA25 9-) SPECIFICATIONS Temperature Sensor In-Vehicle Probe NTC NTC Digital Inputs * * Plug-in socket connection Yes Yes Power Supply: Digital Outputs: Case: Protection Class: Power Consumption: Weight: Mounting: Working Temperature: Storage Temperature: Ambient Relative Humidity: 10 ~ 30 VDC 7 pcs. 700mA (Max.) 118mm X 55mm X 22mm IP65 (Front) 3,5VA (Max.) 0,10 kg (Approximately boxed) 107mm x 43mm horizontally panel cut-out 0 o C ~ +60,0 o C -25 o C ~ +60,0 o C %20 ~ %85 (Without condensing) *: 700mA DIGITAL OUTPUTS FOR A/C, FAN OR DEFROST CONTROL Adress: Maltepe mah. Eski Çırpıcı Yolu Sok. No:3B, NEF12 B Blok Merter, Zeytinburnu/İSTANBUL Factory: Kayı mah. Muratlı Cad. No:389/8 Süleymanpaşa/TEKİRDAĞ Tel: Fax: Mail: info@drcelektronik.com

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue. Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor

More information

DESCRIPTION AND OPERATION

DESCRIPTION AND OPERATION Page 1 of 10 DESCRIPTION AND OPERATION AIR DELIVERY DESCRIPTION AND OPERATION The air delivery description and operation is divided into five areas: HVAC Control Components Air Speed Air Delivery Recirculation

More information

37. FATC (FULL AUTO TEMP. CONTROL) CIRCUIT 6810

37. FATC (FULL AUTO TEMP. CONTROL) CIRCUIT 6810 5156 6810 37. FATC (FULL AUTO TEMP. CONTROL) CIRCUIT 6810 1) CONDENSOR FAN, AIR MIX MOTOR, SUN SENSOR, WATER TEMP SENSOR A. CONNECTOR INFORMATION 6810 5157 Connector Number (Pin Number, Color) Connecting

More information

Inductive Proximity Sensor

Inductive Proximity Sensor ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-110020(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Inductive Proximity Sensor E2Q3 Square

More information

PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233

PSK203/PSK223/PSK233. Digital Thermostats for Low Temperature Refrigerating Units 1 GETTING STARTED PSK203 PSK223 PSK233 September 2012 / Bulletin 100-50-6.2 PSK203/PSK223/PSK233 Digital Thermostats f Low Temperature Refrigerating Units INSTALLATION OPERATING INSTRUCTIONS 1 GETTING STARTED 1.1 Imptant Read these instructions

More information

MC200CAB/4 Integral Version

MC200CAB/4 Integral Version Issue 2.2 Mar 2017 MC200CAB/4 Integral Version Industrial & Commercial Heating Systems. www.powrmatic.co.uk Setting Instructions WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Reset from Lockout is

More information

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

Before performing symptom troubleshooting, check for power train DTCs (see GENERAL TROUBLESHOOTING INFORMATION ).

Before performing symptom troubleshooting, check for power train DTCs (see GENERAL TROUBLESHOOTING INFORMATION ). 2003 Honda Civic 1.7L Eng LX Component AC PRESSURE SENSOR A/C Pressure Switch Circuit Troubleshooting NOTE: Do not use this troubleshooting procedure if any of the following items are operative; condenser

More information

Indoor air quality sensor.

Indoor air quality sensor. Indoor air quality sensor. Options and Accessories, Installation manual Ref.: N-40175_EN 1107 Index Index 1 Indoor air quality sensor... 1 1.1 General Information... 2 1.2 General measurements... 2 1.3

More information

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL. High Load Relay for Smart Junction Box TL RELAYS High heat-resistant type: Sealed Pin in Paste compliant type: Flux tight New 14.4.7 11.433 1.3 FEATURES Large capacity switching

More information

THR1 THR2 THR3 THV1 THV2 THV3

THR1 THR2 THR3 THV1 THV2 THV3 Thermostats THV THR THERMOSTATS Compact Thermostat for DIN 35 mm. rail mounting. Based on bimetallic junction, provides high capacity NO or NC contact. Two versions available: THVx NO Contact Typically

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor E2Q3 Square Proximity Sensor Terminal housing Integrated short circuit and reverse polarity protection Output function programmable by wiring Active face positioning: Y-axis

More information

B-RAD Select USER MANUAL TABLE OF CONTENTS

B-RAD Select USER MANUAL TABLE OF CONTENTS TABLE OF CONTENTS TABLE OF CONTENTS... 1 MANUAL REVISION HISTORY... 2 IMPORTANT SAFETY NOTICE... 3 1.0 General Information... 5 1.1 System Components... 5 1.2 Specifications... 5 1.2.1 Torque Ranges...

More information

PRELIMINARY UNIT OPERATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15

PRELIMINARY UNIT OPERATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15 UNIT OPERATION Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15 UNIT OPERATION Table of content Introduction...3 Operation principle...4 Cab command description...5

More information

Accessories. Series REC

Accessories. Series REC Accessories Series REC 5-7-9 ACCESSORIES REC Series RBA BAF RBE CV3 PC3 SRE PSD CSA GIU TPA O. REC 5 REC 5-6 - 5BT11 5BT6 1CO71 1CO73 1SE96 5PR 1KR6 5SU137 5TE1 REC 5-12 5BT12 5BT122 5BT121 1CO71 1CO73

More information

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE W.CHRISTIE (INDUSTRIAL) LTD CHRISTIE HOUSE, MEADOWBANK ROAD, ROTHERHAM, SOUTH YORKSHIRE, S61 2NF, UK T: +44(0)1709 550088 F: +44(0)1709 550030 E:

More information

Ventilation in balance

Ventilation in balance Ventilation in balance AIRLINQ - DIGITAL BMS PARAMETERS FOR BACNET TM /IP. BACNET TM MS/TP BASIC INFORMATION The present document is only valid for air handling units with firmware version 6. or newer.

More information

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number ST48-WHUV.12 PID controller Order number 935.15 Wiring diagram Product description This micro-processed controller serves for temperature control at high measuring accuracy. Beside resistance sensors and

More information

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES RELIABLE SOLUTIONS in POWER ELECTRONICS RDAT SERIES Power Management Instruments BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES BATTERY CHARGER / DC RECTIFIER RDA / RDAT AUTOMATION

More information

EVD-ice FOR PS SERIES

EVD-ice FOR PS SERIES THE PERFECT COMBINATION EVD-ice FOR PS SERIES EVD-ice Electronic Valve Driver Technology World First: PS Series fitted with EVD-ice HX-514-2 AUS THE PERFECT COMBINATION FROM HOT TO COLD. RUNNING EFFICIENTLY

More information

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE 012945A0 040906 1 MAIN FEATURES Power supply 230V~ ±10% 50Hz Backlit alphanumeric LCD display Management of 5 output

More information

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and pushbutton setpoint adjustment. Additional options include pushbutton override, fan

More information

GEPA. ARG-24 Series Battery Charger & Battery Group. User Guide

GEPA. ARG-24 Series Battery Charger & Battery Group. User Guide GEPA ARG-24 Series Battery Charger & Battery Group User Guide Contents 1. General... 1 2. Features... 2 3. Montage & Wiring... 3 3.1. Montage... 3 3.2. Wiring... 4 4. Usage... 5 4.1. Interface... 5 4.1.1.

More information

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS PCT plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS Ver. DESCRIPTION The PCT plus is a pressure controller for refrigeration plants that require control in their suction and discharge stages. With

More information

Temperature Controller OVATION 214 User's Guide

Temperature Controller OVATION 214 User's Guide Temperature Controller User's Guide Read this guide carefully before using the controller. 890-00045 rev.00 TABLE OF CONTENTS Page TABLE OF CONTENTS... 2 PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE

More information

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY EB RELAYS (AEB) (1A type) FEATURES Compact and high capacity using double contacts in series and permanent magnet installed. (1,A/3 times)

More information

Digital Room Thermostats with Touch Screen LCD

Digital Room Thermostats with Touch Screen LCD TC40 Touch Series Digital Room Thermostats with Touch Screen LCD Revision Date February 22, 2013 Features Wall-mount Display Control to match any decor Extra large easy-to-read Liquid Crystal Display (LCD),

More information

REFRIGERATED CONTAINERS

REFRIGERATED CONTAINERS REFRIGERATED CONTAINERS 2018 Founded in 1958, Öztiryakiler (Ozti) is a leading Turkish manufacturer of Commercial Catering Equipment and Defense Industry Logistic Support Systems. The company manufactures

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

Ventilation in balance

Ventilation in balance Ventilation in balance AIRLINQ - DIGITAL BMS PARAMETERS FOR MODBUS RTU RS485 BASIC INFORMATION The present document is only valid for air handling units with firmware version 6. or newer. The firmware

More information

Braking Unit for Frequency Inverter Serie 3CV V 18,5 bis 55kW

Braking Unit for Frequency Inverter Serie 3CV V 18,5 bis 55kW User manual Braking Unit for Frequency Inverter Serie 3CV 380 480V 18,5 bis 55kW PETER electronic GmbH & Co. KG, Bruckäcker 9, D-92348 Berg Tel. (09189) 4147-0, Fax (09189) 4147-47 email: mail@peter-electronic.com

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor

More information

CX-SERIES ADVANCED BATTERY CHARGER

CX-SERIES ADVANCED BATTERY CHARGER CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...

More information

FULL AUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

FULL AUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM SECTION 7D FULL AUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM FATC (Full Automatic Temperature Control) is full automatic heater and airconditioning system that detects

More information

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA 1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous

More information

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur Valor 1000W Series Instruction Manual Serie Valor 1000W Manual de Instrucciones Série Valor 1000W Guide de I utilisateur Serie Valor 1000W Bedienungsanleitung Serie Valor 1000W Manuale d instruzioni OHAUS

More information

Visit us at

Visit us at testo 810 Instruction manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Short manual testo 810 13 Short manual testo 810 Protection

More information

Module 4: Climate Control

Module 4: Climate Control ÂÂ ÂÂ Air-Conditioning Electronic Control Unit (ECU) Â Controlling Cabin Air Temperature Servo Motors Electric Servo Motors ÂÂ Air-Conditioning Electronic Control Unit (ECU) Automatic Climate Control Sensors

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

AEL.TF.16 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS

AEL.TF.16 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS AEL.TF.16 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS 0120 TS EN ISO 9001 CONTENTS Part Name Page No 0. Introduction 1 1. Introduction Technical Specifications of

More information

WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY Instruction Manual HBDF MK2 Defrost Sensor For automatic defrosting of evaporators Simple Setup, only two parameters and execution of a zero/start point during start-up. instruction manual - HBDF mk2 defrost

More information

PCT-3001 plus. Display LCD

PCT-3001 plus. Display LCD PCT3 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS DESCRIPTION Pressure controller for refrigeration systems capable to control suction (compressors) and discharge (fans) pressures. It is possible

More information

Part # Features & Applications Specifications Cross Reference

Part # Features & Applications Specifications Cross Reference Solid State Controls 24-ICM450 24-ICM400 Fully Programmable - with LCD diagnostic display. Easy to configure - simple 7-step push-button setup. Easy to customize - set points, variables and features are

More information

HERZ Electronic room thermostat analog and digital

HERZ Electronic room thermostat analog and digital Dimension in mm 3 F799 11-3 F799 14 HERZ Electronic room thermostat analog and digital Data sheet for F799, Issue 0317 3 F799 15 3 F799 18 Mounting plate Page 1 Technical data 3 F799 11-14 3 F799 15-18

More information

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary drops up to % of rated. Wide-range AC-activated coil that handles 1 to 1 or to

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION Sensor INSTRUCTI MANUAL Head Separated Digital Sensor Controller DPC-1 Series MJE-DPC1 No.7-98V Thank you very much for using SUNX products. Please read this Instruction Manual carefully and thoroughly

More information

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down DC-DC Converter has a digitally adjustable output in 0.2V increments. This

More information

STRA-24 for chilled beams

STRA-24 for chilled beams STRA- Installation and commissioning manual STRA- for chilled beams STRA- is the room controller for the pressure independent (Pi) and constant air volume chilled beams. It is possible to set different

More information

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES Article Text ARTICLE BEGINNING 1993 AIR CONDITIONING & HEAT A/C General Diagnostic Procedures Diagnosis is an important first step in A/C system servicing. To save time and effort, systems should be carefully

More information

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication

More information

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used

More information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION... CONTENTS 1. INTRODUCTION...... 1 2. SAFTY INSTRUCTION.......... 2 3. CABLE CONNECTION.......... 4 4. SYSTEM DESCRIPTION............ 5 5. INVERTER OPERATION... 11 6. TROUBLE SHOOTING GUIDE....... 16 7.

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL

SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Instruction Manual SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.14 (August, 215) 1. Caution 3. Terminal Assignment Model SWA-2441 Model SWA-2451 This controller is intended to

More information

EFFICIENT SLEEPER COMFORT. Volvo s Battery-powered Parking Cooler Option

EFFICIENT SLEEPER COMFORT. Volvo s Battery-powered Parking Cooler Option EFFICIENT SLEEPER COMFORT Volvo s Battery-powered Parking Cooler Option Cooling comfort and anti-idle value. Most environmentally-friendly and efficient solution for sleeper comfort Overnight comfort without

More information

Differential Pressure Sensor

Differential Pressure Sensor Differential Pressure Sensor "Cube" Type Differential Pressure Sensor with LED Display Offers High Precision Sensing 31 (1.) x 3 (1.18) x 3 (1.18) mm compact-cube style saves mounting space Easy-to-read

More information

3.10 Air Conditioning (A/C) Contents

3.10 Air Conditioning (A/C) Contents 3.10 Air Conditioning (A/C) Contents 3.10 Model 208 as of M.Y. 1998 Diagnosis Page Function Test................................... 11/1 Reading Actual Values............................ 12/1 Version Code...................................

More information

HWP Protection Board

HWP Protection Board February 2009 HWP Protection Board Features and Operation This board provides the system protection features necessary to keep our HWP (Water Sourced Heat Pump) units safe in the instances when they are

More information

ASSEMBLY INSTRUCTIONS ZONE MODULE 2 1 THERMOSTAT DESCRIPTION POWER SUPPLY AIRZONE CONTROLLER

ASSEMBLY INSTRUCTIONS ZONE MODULE 2 1 THERMOSTAT DESCRIPTION POWER SUPPLY AIRZONE CONTROLLER ZONE MODULE 2 1 ASSEMBLY INSTRUCTIONS AIRZONE CONTROLLER THERMOSTAT DESCRIPTION The Touch Thermostat, is the access panel for the installer to configure the Zone Module, and also, for the user to change

More information

Legat-65. Voltage Stabilizer Technical Certificate. NOVATEK-ELECTRO LTD Research-and-Manufacture Company

Legat-65. Voltage Stabilizer Technical Certificate.   NOVATEK-ELECTRO LTD Research-and-Manufacture Company NOVATEK-ELECTRO LTD Research-and-Manufacture Company Legat-65 Voltage Stabilizer Technical Certificate www.novatek-electro.com 1. Application Legat-65 single-phase voltage stabilizer, hereinafter referred

More information

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy otor Controllers AC Semiconductor otor Controller Type RSHP Flexy Soft starting and stopping of 3-phase squirrel cage motors Low surge and vibration-free starting User-selected ramping profiles Integral

More information

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0 Products Tde Macno User s Manual BRAKING UNIT Cod. MP00401E00 V_1.0 SUMMARY 1 GENERAL DESCRIPTION... 2 2 USE LIMITATIONS... 2 2.1 Climatic Class... 2 2.2 Resistance To Chemically Active Substances...

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

Power Controller. (see note 1) 10 sec

Power Controller. (see note 1) 10 sec Power Controller Single-phase Models EUN Series AC Power Controller with Phase-control System Allows Precise Temperature Control Models with Base-up and Soft-start Functions Available EH Series Phase Control

More information

¼ to 1HP Chiller Service Manual

¼ to 1HP Chiller Service Manual ¼ to 1HP Chiller Service Manual Before performing any service to the unit, reset the controller to its default settings. It is our experience that many problems can be resolved by doing so. See Sec. 3.1

More information

Differential pressure sensor

Differential pressure sensor s 1 916 QBM3x20-.. QBM3x20-..D Differential pressure sensor for air and non-aggressive gases QBM3020-.. QBM3120-.. High degree of measuring accuracy Adjustable characteristic curve (pressure-linear or

More information

AC drive has detected too high a Check loading

AC drive has detected too high a Check loading Fault code Fault Name Fault type Default Possible Cause Remedy 1 Over Current Fault AC drive has detected too high a Check loading current (>4*IH) in the motor cable: Check motor Sudden heavy load increase

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

Fan Coil Thermostat. Specification & Installation instructions TFC54F3X1. Technical Data

Fan Coil Thermostat. Specification & Installation instructions TFC54F3X1. Technical Data Fan Coil Thermostat Feature: Selectable analog & digital output Selectable fan speed contact Selectable Fahrenheit or Celsius scale Manual Night Set Back override (programmable) Multi level lockable access

More information

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend Power Controllers GPX Refer to Safety Precautions (page 0). Single-phase Models EUN Series AC Power Controllers with Phase-control System Allow Precise Temperature Control Models with Base-up and Soft-start

More information

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus: 1.0 Introduction: This probe is designed to provide an additional help to automotive technicians in trouble shooting of electrical circuits problems in the car. Apart from using the normal multi tester,

More information

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL Temperature Controller TC5+2V4SA Plus USER'S MANUAL NOTICE Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information contained in it is however subject

More information

LEAB Voltage converter

LEAB Voltage converter Product Specification Idavägen 11 352 46 Växjö Tel +46 470 72 74 95 Fax +46 470 72 74 99 www.primepower.se LEAB Voltage converter 0037195 General description This LEAB Voltage conditioner is designed for

More information

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9. SED2 with Conventional Bypass Options Important Note: VD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

KE2 Parts & Accessories

KE2 Parts & Accessories Bulletin B.9.1 July 2014 KE2 Therm Solutions Providing Advanced Energy Saving Technology for Commercial Refrigeration and AC Systems. Page 2 Alphabetical Listing of Parts & Accessories Product Name Description

More information

DT304. Digital Temperature Logger INSTRUCTION MANUAL

DT304. Digital Temperature Logger INSTRUCTION MANUAL Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com DT304 INSTRUCTION MANUAL Digital Temperature Logger TABLE OF CONTENTS Introduction..........................................1

More information

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00 TECHNICAL MANUAL EN Inverter / Charger Combi Combi SW 12V 1600VA Réf : PF.16088 Combi SW 24V 3800VA Réf : PF.16089 SAFETY PRECAUTIONS TO PREVENT ANY RISK OF ELECTRIC SHOCK OR FIRE, READ THIS MANUAL CAREFULLY

More information

SRT1000 Series THERMAL FLOWMETER

SRT1000 Series THERMAL FLOWMETER High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such

More information

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input) Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai- Ph: + Fax: E-mail: info@intechchennai.com Website: www.intechchennai.com Temperature Controllers ECS CSM_ECS_DS_E Simple Functi ons in

More information

BAPI-Stat 3 Room Sensor

BAPI-Stat 3 Room Sensor Overview and Identification The BAPI-Stat 3 is a multiple output transmitter for temperature and humidity with setpoint capability for both and occupied/unoccupied override switching. The large easy-to-read

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72 BT D-01 1 2 USER GUIDE GB Digital Thermostat 4-25 GUIDE D UTILISATION F Thermostat digital 26-49 Bedienungsanleitung D Termostato digital 50-72 GUÍA DE USUARIO ES Termostato digital 74-97 GUIA DO UTILIZADOR

More information

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified. ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified. Environmentally friendly Ultra Deep Freezer, -40 degree powered by Meditech Technology for safe storage. Stable Temperature Control Temperature is

More information

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C ELECTRIC POWER REGULATION STS converts 0 10 V signal to one time proportional and up to 3 contact. Each step must be identical in power. input output 1 2- number of steps 2 Vac, 1 VA 0 10 Vdc < 1 ma for

More information

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features Product Guide ALC-PRM-VFC Ceiling Mounted Photocell Overview The ALC-PRM-VFC photocell will turn lighting on when the ambient light falls below a preset level. The lighting will then be turned off when

More information

THE ALT AL ERNA RN T A OR

THE ALT AL ERNA RN T A OR THE ALTERNATOR Initial Voltage of the Battery (Engine Not Running) Charging Voltage for the Battery (Engine Running) Testing for Maximum Output of the Alternator Inspecting the Regulator Positive Side

More information

SafetyPAT Plus A B P/N:

SafetyPAT Plus A B P/N: SafetyPAT Plus A B C P/N:110401103864 Test Instrument Solutions SafetyPat Plus Instructions A.Features SafetyPat Plus The SafetyPat Plus is a handheld battery powered unit suitable for carrying out electrical

More information

Lumitester PD-20 Control Kit

Lumitester PD-20 Control Kit 日本語による取扱説明は 17 ページからとなります Lumitester PD-20 Control Kit Operation manual Thank you for purchasing the Lumitester PD-20 Control Kit. To use this kit safely and correctly, read this operation manual carefully

More information

EX3: stepper motor valve with safety embedded solenoid ON/OFF valve

EX3: stepper motor valve with safety embedded solenoid ON/OFF valve pag. 1 / 11 EX3: stepper motor valve with safety embedded solenoid ON/OFF valve The EX3 electronic expansion valve provides precise refrigerant flow control and optimizes system superheat. EX3 is the ideal

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Square Proximity Sensor Terminal housing Active face changeable to one of every five Easy to install and same mounting dimensions as a standard style electromechanical limit

More information

Condensation monitor

Condensation monitor QXA2101 QXA2100 Condensation monitor QXA2100 QXA2101 Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power. Can also be used with extension module AQX2000

More information

E2K-L. Liquid Level Sensor. Applications. Ordering Information

E2K-L. Liquid Level Sensor. Applications. Ordering Information Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom KCR1 Kiln Controller Handbook Issue: a b Date: 04Sep2008 05Sep2008 Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom Tel: 01782 535915 Tel:

More information