KE2 Parts & Accessories

Size: px
Start display at page:

Download "KE2 Parts & Accessories"

Transcription

1 Bulletin B.9.1 July 2014 KE2 Therm Solutions Providing Advanced Energy Saving Technology for Commercial Refrigeration and AC Systems.

2 Page 2 Alphabetical Listing of Parts & Accessories Product Name Description Part Number(s) Page Number Additional Literature Buzzer For use with the KE2 Evaporator Efficiency and KE2 Controlled Environment NA Buzzer/Light For use with the KE2 Evaporator Efficiency and KE2 Controlled Environment NA Door Switch Solid aluminum housing, for use with the KE2 Low Temp + Defrost, KE2 Evaporator Efficiency and KE2 Controlled Environment NA Ethernet Adaptor Kit For use with the KE2 Evaporator Efficiency and KE2 Controlled Environment NA Ethernet Cable CAT5e Shielded Ethernet Cable with Connectors 50 ft ft NA Ethernet Cable - Bulk CAT5e Shielded Ethernet Cable - Bulk 1,000 ft NA Ethernet - CAT5e RJ-45 Plug For use with CAT5e shielded solid STP cable 50 micron - 50 pack NA Flag Quick Disconnect Insulated, AWG - 50 pack NA Fuses - 1/2 Amp 250V, 0.5A Time Delay Glass; Replacement fuses for the KE2 Evap and KE2 Controlled Environment - 5 pack NA Fuses - 3 Amp 250V, 3.0A Fast Acting Ceramic; Replacement fuses for the KE2 Terminal Board - 5 pack NA Fuses - 12 Amp 250V, 12A Time Delay Ceramic; Replacement fuses for the KE2 Terminal Board - 5 pack NA Fuses - 20 Amp 250V, 20A Fast Acting Ceramic; Replacement fuses for the KE2 Terminal Board - 5 pack NA KE2 SmartGate Pre-configured 10-port router B.5.2, Q.5.24, Q.5.25 KE2 Terminal Board Simplifies installation of the KE2 Evaporator Efficiency, KE2 Controlled Environment and KE2 Low Temp + Defrost Q.1.30 KE2 WiFi Service Tool Service tool for KE2 Evaporator Efficiency and KE2 Controlled Environment Q.5.26 KE2 Wire Harness For wiring the KE2 Evap, KE2 Controlled Environment and KE2 Low Temp; 9-wire, color coded 25 ft ft Q.1.21 Mounting Box Simplifies installation of the KE2 Evap and KE2 Controlled Environment; Q.1.21 Pressure Transducer 0 to 150 psia 10 ft ; 40 ft NA Pressure Transducer 0 to 300 psia 10ft NA Sensor - Humidity For use with the KE2 Controlled Environment, 40 ft. leads N.1.3, Q.1.23 Sensor - Temperature Temperature sensor - NTC Thermistor Assembly 10 ft ; 40 ft N.7.1 Sensor Mount for Air Sensor (20) pack Q.1.3 Switch 8-port 8-port Ethernet switch Q.5.2 Switch 16-port Industrial 16-port Ethernet switch NA Temperature Sensor Clip with Spring - 3/8 Coil sensor mount NA Temperature Sensor Clip with Spring - 1/2 Coil sensor mount NA Temperature Sensor Clip with Spring - 5/8 Coil sensor mount NA

3 Page 3 25 Wire Harness pn Wire Harness pn The wire harness simplifies installation of the KE2 Evaporator Efficiency (KE2 Evap), KE2 Controlled Environment, and the KE2 Low Temp + Defrost controllers by providing color coded wires with connectors that correspond to the controller s inputs. This speeds installation by reducing on site wire preparation time by over 3/4 hour, and eliminates the need to stock multiple wire gauges, colors and connectors. The stranded wires used in the harness are flexible, making them easier to pull and route, and the wire harness is kept from tangling by a cable tie at each end. The wires are 25 or 40 from cable tie to cable tie, making the overall harness approximately a foot longer. Additionally, on return visits, the wiring is standardized, so there is no question about which wire goes to what. Defrost Heat orange w. black stripe 12 AWG flag connectors black w. orange stripe (L1) 12 AWG flag connectors Fans blue w. black stripe 14 AWG flag connectors black w. blue stripe (L1) 14 AWG flag connectors LLS/Compressor black w. yellow stripe (L1) Yellow w. black stripe Power black (L1) white (L2 or neutral) Ground green Function Color Gauge Wire Ends Power black with white stripe L1 16 AWG stripped and retained Power white with red stripe L2/neutral 16 AWG stripped and retained Ground green 16 AWG stripped and retained Defrost Heat orange with black stripe 12 AWG flag connectors Defrost Heat black with orange stripe L1 12 AWG flag connectors Fans blue with black stripe 14 AWG flag connectors Fans black with blue stripe L1 14 AWG flag connectors LLS/Compressor yellow with black stripe 16 AWG stripped and retained LLS/Compressor black with yellow stripe L1 16 AWG stripped and retained

4 Page 4 Mounting Box pn 20687* Constructed of 40 mil embossed aluminum, the box measures 12.3 x 6.4 x 2.0 inches and includes the necessary hardware to mount the box and controller. When installing the KE2 Evaporator Efficiency or KE2 Controlled Environment, the mounting box provides a stationary location to attach conduit, allowing the controller to be secured for easy installation and service. The box is sized to accommodate the controller s wiring, providing space for storing the service loops. Constructed of stamped aluminum, the box blends into the refrigeration environment, providing a clean appearance to the finished install. *Included in the Ultimate Install Kit, pn Mounting Box shown in photo with Wire Harness and KE2 Evaporator Efficiency controller KE2 Terminal Board pn Matches the wiring needs of the KE2 Evap, KE2 Low Temp + Defrost, and the KE2 Controlled Environment, the KE2 Terminal Board, makes installing KE2 Therm controllers one step closer to foolproof. KE2 Terminal Board standardizes the wiring for every install, and the board is marked with well known symbols for the fan, heaters, and LLS, making future diagnostics instantly recognizable. Additionally, the built in fuse on the terminal board protects every relay on the controller from power surges, and once a component failure is identified, the controller can be up and running quickly. *Included with the KE2 Evaporator Efficiency and KE2 Controlled Environment KE2 Terminal Board shown with the Wire Harness Door Switch pn Specifically designed for rugged high traffic installations. The reed switch is hermetically sealed with a PVC shock absorber enclosed within a solid aluminum housing. Installation wires are protected in a 24 stainless steel armored cable. The magnet is mounted on an adjustable L shaped bracket for greater flexibility, universal mounting, and greater pulling power. Contact - 22AWG 24 Leads Contact Rating - 10 VA Contact Type -Normally Open Max. Carry Current - 2 Amp Max. Switching Current -.5 Amp Breakdown Voltage VDC Operating Gap - 2 Temperature Range - 32 F to 120 F (0 C to 49 C) Humidity Sensor pn The humidity sensor comes pre-configured and pre-wired with a 40 foot lead. Installers should not open the watertight housing and make adjustments without consulting KE2 Therm Technical Support. If the sensor must be located more than 40 feet from the controller, the cable may be extended to 100 feet using18/3 stranded, shielded cable.

5 Page 5 Buzzer pn mm, 25 ma audible (80dB at 10 cm) buzzer annunciator. 120VAC/DC Buzzer & Light pn mm, 25 ma audible (80dB at 10 cm) buzzer annunciator with non-replaceable LED indicator. 120VAC/DC Fuses (sold in 5 packs - part number is for 5 pack) 1/2 Amp pn V, Time Delay Glass - for electronics protection 3 Amp pn V, Fast Acting Ceramic; for LLS/Compressor 12 Amp pn V, Time Delay Ceramic; for Fans 20 Amp pn V, Fast Acting Ceramic; for Defrost Heaters Flag Quick Disconnects - 50 pk. pn Insulated, AWG Ideal for connections with limited space. Pressure Transducer - 0 to 150 psia 10 ft. lead pn ft. lead pn Pressure Transducer - 0 to 300 psia 10 ft. lead pn Temperature Sensor - 10 ft. lead pn Temperature Sensor - 40 ft. lead pn K Ω NTC at 77 F Operating range -60 F to 150 F Quick response and precise thermal tracking IP68 moisture protection 10,000 freeze/thaw thermal cycles Sensor Mount for Air Sensor pn Replacement mounts for the air sensor. Holds the air sensor at the desired 8-10 distance from the evaporator. Sensor Coil Clip - 3/8 circuit tube pn Sensor Coil Clip - 1/2 circuit tube pn Sensor Coil Clip - 5/8 circuit tube pn For applications with evaporator fins that have wider spacing. Rather than pressing the fins together to hold the sensor bulb, the bulb inserts in the spring, which is then clipped on to the evaporator circuit tube. Sensor sold separately.

6 Page 6 Network Switches When multiple controllers are attached to a KE2 Switch, once bonded, the KE2 Switch forms the foundation of a local Refrigeration Network. This local Refrigeration Network facilitates communications between controllers, plus provides a path for communications to the Internet. The controllers are linked via an Ethernet cable to the KE2 Switch. Benefits of KE2 Switch Communication: Air Sensor - If one controller in the Refrigeration Network experiences a temperature sensor error, the controllers will send the impaired controller either the average temperature or the highest temperature in the space, allowing the controller to continue operating until it can be serviced. pressure may be shared if errors are detected. When sharing pressures, the lowest pressure is used to ensure liquid doesn t return to the compressor. Defrost Cycles - Coordinating defrost cycles is also extremely important. Depending on the type of defrost method selected, the KE2 Evaporator Efficiency will modify the sequence of operation to maximize the system operation. In addition to communicating with each other, the controllers can be connected to the Internet. This provides many extra features such as; remote real time status monitoring, set point adjustments, and alert message notifications. Suction Pressure - Similar to the sensor reading, suction Network Switch - 8 port pn Specifications Construction sturdy metal case Interface 8 x 10/100/1000Mbps Auto-MDIX RJ-45 ports Standards IEEE Base-T IEEE 802.3u 100Base-TX IEEE 802.3ab 1000Base-T IEEE 802.3x Flow Controller Network Media Ethernet: CAT. 3,4,5 up to 100m Fast Ethernet: CAT. 5 up to 100m Gigabit Ethernet: 2000Mbps (full-duplex) Switch Fabric 16 Gbps forwarding capacity Diagnostic LEDS Power, Link/AST, Speed Specifications Network Switch - 16 port pn Specifications Construction sturdy metal case Interface 16 x 10/100/1000Mbps Auto-MDIX RJ-45 ports Standards IIEEE Base-T IEEE 802.3u 100Base-TX IEEE 802.3ab 1000Base-T IEEE 802.3x Flow Control IEEE 802.3az Energy Efficient Ethernet Network Media Ethernet: Cat. 5 up to 100m Fast Ethernet: Cat. 5 and 5e up to 100m Gigabit Ethernet: Cat. 5e and 6 up to 100m Switch Fabric Power, Link/ACT, 100Mbps, 1000Mbps Diagnostic LEDS Power, Link/AST, Speed

7 Page 7 KE2 SmartGate pn The KE2 SmartGate is the heart of the Refrigeration Network. It provides the KE2 Evaporator Efficiency controller with the ability to communicate easily and immediately both locally and remotely. Although KE2 Therm does not require special equipment for communication with our devices, many users have requested a pre-configured solution to simplify the creation of the Refrigeration Network. Using feedback from many field installations, KE2 Therm s engineers have created the KE2 SmartGate. The KE2 SmartGate natively provides the user with a powerful tool designed to simplify any installation from a basic single controller to the most advanced multi-controller setup. The onboard set of tools are fully supported by KE2 Therm s Technical Support team to make the installation even smoother. Locally it provides wired or wireless access to the controllers without special configurations of the user s PC. Pre-configured - eliminates the need to configure the network Industrial grade - increased speed and durability Provides 9 LAN ports - reduces the need for a switch Not an IT guy...not a problem! Specifications CPU Memory Ethernet Wireless Expansion USB POE Antenna Gain TX Power 600MHz 128MB Gigabit Ports 5 10/100 Ports B/G/N Fixed Gigabit Ethernet SFP cage MicroUSB (powered) ETH1 (8-28v DC) 4dbi 30dBmDH Additional Features Supports single mode and multi mode CP Server and Client VPN Server and Client IPv4 and IPv6 Reset Button Reset Jumper RJ-45 Serial Port LCD Panel Temperature Sensor Voltage Sensor General Features Commercial Grade LAN Ports 9 Gigabit Support Serial Console POE (Power Over Ethernet) Shielded Ports Fiber Supports KE2 - EZVPN Wired and Wireless Models Supports > 20 Devices Enterprise Ready Temp Range Humidity Range -30 F(-35 C) to 150 F (+65 C) Max. 90% (non-condensing)

8 Page 8 KE2 WiFi Service Tool pn KE2 WiFi Service Tool is the simplest, most cost effective, way to access the KE2 Evaporator Efficiency s or KE2 Controlled Environment s Graphical User Interface (GUI) web pages of the controller. When connected to the controller, the service tool creates nearly instant wireless access to the web pages on the controller. Users may connect their cellphones, tablets, or laptop computers to the unsecured wireless network. Ethernet Adaptor Kit pn Provides easy access to the Ethernet port on the backside of the controller. Once the adaptor is connected there is no need to remove the controller from the mounting screws to access the Ethernet connection on return visits. Ethernet Cable Commercial /industrial temperature range CAT5e Shielded Ethernet cable. Shielding helps prevent noise interference with communications, while the expanded temperature range rating keeps the cable from becoming rigid and damaged over time. CAT5e Shielded Ethernet Cable - 50 ft. pn CAT5e Shielded Ethernet Cable ft. pn Shielded RJ-45 connections are attached CAT5e Shielded Ethernet Cable - Bulk 1000 ft. pn Does not include RJ-45 connections - see part number sold separately. Shielded Ethernet CAT5e RJ-45 Plugs - 50 pk pn High quality, shielded RJ-45 connections help prevent noise from interfering during communications. For use with CAT5e shielded solid STP cable 50 micron. KE2 Therm Solutions, Inc. 209 Lange Drive. Washington, MO

indoor access point MIMO New Series

indoor access point MIMO New Series MIMO New Series Dual Band 2x2 MIMO 802.11ac/a/b/g/n Versatile Indoor Access Point 710MHz CPU / 2x GE Port / 802.11ac Wave 2 Model: MMN428HV KEY FEATURES Qualcomm Atheros IPQ4028 Quad-core ARM cortex-a7

More information

MIMO Zen Series. Dual Band 2x2 MIMO ac/b/g/n Enterprise Indoor Access Point 560MHz CPU / 2.4GHz at 300Mbps / 5GHz at 867Mbps

MIMO Zen Series. Dual Band 2x2 MIMO ac/b/g/n Enterprise Indoor Access Point 560MHz CPU / 2.4GHz at 300Mbps / 5GHz at 867Mbps MIMO Zen Series Dual Band 2x2 MIMO 802.11ac/b/g/n Enterprise Indoor Access Point 560MHz CPU / at 300Mbps / at 867Mbps Model: MMZ344 KEY FEATURES Qualcomm Atheros 560MHz Processor AR9344 IEEE 802.11ac/a/b/g/n

More information

MIMO Zen Series. Dual Band 3x3 MIMO ac/b/g/n High Bandwidth Indoor Access Point 700MHz CPU / 2.4GHz at 450Mbps / 5GHz at 1300Mbps

MIMO Zen Series. Dual Band 3x3 MIMO ac/b/g/n High Bandwidth Indoor Access Point 700MHz CPU / 2.4GHz at 450Mbps / 5GHz at 1300Mbps MIMO Zen Series Dual Band 3x3 MIMO 802.11ac/b/g/n High Bandwidth Indoor Access Point 700MHz CPU / at 450Mbps / at 1300Mbps Model: MMZ558 KEY FEATURES Qualcomm Atheros 700MHz Processor QCA9558 IEEE 802.11ac/a/b/g/n

More information

PRELIMINARY COMPEX SYSTEMS

PRELIMINARY COMPEX SYSTEMS MIMO Junior Series Dual Band 2x2 MIMO /b/g/n Long Range Outdoor Access Point 2x2 at 300Mbps / 2x2 at 867Mbps (Wave-2) Specifications Chipset System Memory NOR Flash Antenna Interface Reset Button LED Power

More information

PRELIMINARY COMPEX SYSTEMS

PRELIMINARY COMPEX SYSTEMS Dual Band 2x2 MIMO /b/g/n High Bandwidth Indoor Access Point at 300Mbps / at 867Mbps (Wave-2) Specifications Chipset System Memory NOR Flash Antenna Interface Reset Button LED Power Over Ethernet Board

More information

MIMO Zen Series. Dual Band 3x3 MIMO ac/b/g/n High Bandwidth Indoor Access Point 775MHz CPU / 2.4GHz at 450Mbps / 5GHz at 1300Mbps (Wave-2)

MIMO Zen Series. Dual Band 3x3 MIMO ac/b/g/n High Bandwidth Indoor Access Point 775MHz CPU / 2.4GHz at 450Mbps / 5GHz at 1300Mbps (Wave-2) MIMO Zen Series Dual Band 3x3 MIMO 802.11ac/b/g/n High Bandwidth Indoor Access Point 775MHz CPU / at 450Mbps / at 1300Mbps (Wave-2) Model: 3x3 MMZ563 KEY FEATURES Qualcomm Atheros 775MHz Processor QCA9563

More information

MIMO Zen Series. Dual Band 3x3 MIMO ac/b/g/n High Bandwidth Indoor Access Point 700MHz CPU / 2.4GHz at 450Mbps / 5GHz at 1300Mbps

MIMO Zen Series. Dual Band 3x3 MIMO ac/b/g/n High Bandwidth Indoor Access Point 700MHz CPU / 2.4GHz at 450Mbps / 5GHz at 1300Mbps MIMO Zen Series Dual Band 3x3 MIMO 802.11ac/b/g/n High Bandwidth Indoor Access Point 700MHz CPU / at 450Mbps / at 1300Mbps Model: MMZ558 KEY FEATURES Qualcomm Atheros 700MHz Processor QCA9558 IEEE 802.11ac/a/b/g/n

More information

IEDA524-H / IEDA520DTB DIGITAL MICROPHONE STATION. Installation Instructions

IEDA524-H / IEDA520DTB DIGITAL MICROPHONE STATION. Installation Instructions IEDA524-H / IED0520DTB DIGITAL MICROPHONE STATION Installation Instructions REV: 12-12 DOC: 369B INSTALLATION INSTRUCTIONS INTRODUCTION Description The IED 524 digital microphone station is a 4-button

More information

QUANTUM LX CONTROL PANEL

QUANTUM LX CONTROL PANEL Form E90-020 SPC (APR 2006) File: EQUIPMENT MANUAL - Section 90 Replaces: E90-020 SPC (JUN 2005) Dist: 1, 1a, 1b, 1c, 4a, 4b, 4c QUANTUM LX CONTROL PANEL The most technologically advanced screw compressor

More information

outdoor access point Multi Point Station Series

outdoor access point Multi Point Station Series Multi Point Station Series Dual Band 2x2 MIMO 802.11ac/b/g/n Long Range Outdoor Access Point 560MHz CPU / 300Mbps / 867Mbps Model: MPS344 KEY FEATURES Qualcomm Atheros 560MHz Processor AR9344 IEEE 802.11ac/a/b/g/n

More information

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING: WARNING: www.altronicinc.com DEVIATION DEVIATION FROM THESE FROM INSTRUCTIONS THESE INSTRUCTIONS MAY LEAD MAY TO LEAD IMPROPER TO IMPROPER OP- ERATION OF ENGINE THE MACHINE

More information

Multi Point Station Series

Multi Point Station Series Multi Point Station Series Dual Band 2x2 MIMO 802.11ac/b/g/n Long Range Outdoor Access Point 560MHz CPU / 300Mbps / 867Mbps Model: MPS344 KEY FEATURES Qualcomm Atheros 560MHz Processor AR9344 IEEE 802.11ac/a/b/g/n

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS Date of last update: Apr-15 Ref: D7.8.4/0112-0415/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS CoreSense Diagnostics for Stream Refrigeration Compressors...

More information

Intelligent DC UPS Module

Intelligent DC UPS Module Intelligent DC UPS Module 12V/9~36V DC Input, 12V DC Output Uninterruptible Power Supply Module with Diagnostics VESA or VESA mounting 9-36V input through terminal or power jack, or 12V through power jack

More information

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry

More information

Illustrated Parts Guide DSD EDGE 120VAC. Page 1 of 32

Illustrated Parts Guide DSD EDGE 120VAC. Page 1 of 32 Illustrated Parts Guide DSD EDGE 120VAC Illustrated Parts Guide Page 1 of 32 This document is designed to provide a quick reference to the major replacement parts and components for the DSD EDGE. Parts

More information

LaserJet 1300 series printer

LaserJet 1300 series printer Electronic Accessories Cable (Interface) HP Parts Reference Guide 8120-8485 Universal Serial Bus (USB) interface cable - Type 'A' connector to type 'B' connector, 1.8m (6.0 ft) long 8121-0712 Universal

More information

C6502A HP IEEE 1284 parallel printer port module - Plugs into the LIO module slot - Comes standard with the LaserJet 1300 series printers

C6502A HP IEEE 1284 parallel printer port module - Plugs into the LIO module slot - Comes standard with the LaserJet 1300 series printers Electronic Accessories Cable (Interface) 8120-8485 Universal Serial Bus (USB) interface cable - Type 'A' connector to type 'B' connector, 1.8m (6.0 ft) long 8121-0712 Universal serial bus (USB) interface

More information

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS DIFFERENTIAL TEMPERATURE CONTROLLERS MAIN FEATURES - Microprocessor programed specifically for optimal performance of WARM AIR systems - Large easy-to-read 40 character (x0) backlit LCD display showing

More information

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4 QUICK START GUIDE FOR ACCESS CONTROL BOARDS DX Series Four Door TCP/IP Web Server Controller Model: ACP-DXEL Table of Contents 0- Introduction 0 - Overview 0. - Package Contents 0. - Installation Requirements

More information

accessory guide Indoor AP Accessories Compatible Products Description Picture Kit Contents

accessory guide Indoor AP Accessories Compatible Products Description Picture Kit Contents Indoor AP Compatible Products Description Picture Kit Contents 902-0100-0000 ZoneFlex 7982 ZoneFlex R700 Multipurpose mounting bracket for 7982 supports mounting to hard wall, ceiling, electrical outlet

More information

KE2 Low Temp+Defrost (pn 20903) Quick Start Guide

KE2 Low Temp+Defrost (pn 20903) Quick Start Guide KE2 Low Temp+Defrost (pn 20903) Q.1.29 November 2014 This reference should remain on site with the installed KE2 Low Temp + Defrost controller. B C A I J D E F G H Parts List The following parts are included

More information

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED CONDENSING REMOTE SYSTEMS UNITS 50hz HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM 3.6 to 16.0 kw (12 200 to 54 700 Btuh) HS18 Bulletin

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before

More information

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS DIFFERENTIAL TEMPERATURE CONTROLLERS MAIN FEATURES - PV POWERED from 0 V to VDC with smart power management at very low PV power levels, A must, for soft FAN start & smooth controller operation - Microprocessor

More information

Uninterruptible Power Supplies

Uninterruptible Power Supplies SDU Series, Direct Current Uninterruptible Power Supply (DC UPS) System The SDU DIN Rail DC UPS is an advanced uninterruptible power system that combines an industry leading design with a wide operational

More information

Visit our web site at AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS

Visit our web site at   AMR LS-3000, LS-3010 & LS-3020 BELT SLIP/SEQUENCE CONTROL INSTALLATION AND SETUP INSTRUCTIONS AMR INC. DESIGN & MANUFACTURING FOR MINING WORLDWIDE P.O. BOX 234, ROCKY GAP, VA 24366 PHONE (276)928-1712 FAX (276)928-1814 Email sales@americanmineresearch.com Visit our web site at www.americanmineresearch.com

More information

KE2 Temp + Defrost (pn 20611) Installation Manual

KE2 Temp + Defrost (pn 20611) Installation Manual Q.1.20 February 2013 (pn 20611) Installation Manual This reference should remain on site with the installed controller. B E A C F D What s in the Kit - Parts List The following parts are included in the

More information

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA ENGINEERING DATA ENGINEERING DATA MATCHED REMOTE SYSTEMS 50hz HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw (60 200 to 222 500 Btuh) HS17 Bulletin #490001 November 1995 Supersedes August 1994 HS17-1353

More information

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors Unidrive M600 High performance drive for induction and sensorless permanent magnet motors 0.75 kw - 2.8 MW Heavy Duty (1.0 hp - 4,200 hp) 200 V 400 V 575 V 690 V Unidrive M600 features Easy click-in keypad

More information

Part # Features & Applications Specifications Cross Reference

Part # Features & Applications Specifications Cross Reference Solid State Controls 24-ICM450 24-ICM400 Fully Programmable - with LCD diagnostic display. Easy to configure - simple 7-step push-button setup. Easy to customize - set points, variables and features are

More information

LUI / LUO. Condensing Units

LUI / LUO. Condensing Units UI / UO Condensing Units Standard Construction Cabinet: The rugged cabinet is constructed of heavy gauge, mill galvanized steel. Easily removable top and personnel screen are provided for convenient component

More information

- Wiring Brochure tn4 Gateway 483

- Wiring Brochure tn4 Gateway 483 - Wiring Brochure Gateway 483 W 483 03/10 1 Infmation Brochure Application Brochure Choose controls to match application Design your mechanical applications 2 3 Rough-in Wiring Rough-in 4 Wiring Brochure

More information

10AC DIPLOMAT SERIES RFC SYSTEMS

10AC DIPLOMAT SERIES RFC SYSTEMS 10AC DIPLOMAT SERIES CONDENSING UNITS RFC SYSTEMS 10.05 to 10.55 SEER *11,100 to 60,000 Btuh (3.3 to 17.6 ) 1 thru 5 Tons (3.5 to 17.6 ) *ARI and DOE Certified Ratings CONDENSING ENGINEERING UNITS DATA

More information

Typical Applications. Horizontal Installation

Typical Applications. Horizontal Installation ENGINEERING DATA COILS COIL UNITS CB19 AND CBH19 SERIES UP-FLOW, DOWN-FLOW AND HORIZONTAL COIL UNITS *12,600 to 65,500 Btuh (3.7 to 19.2 kw) Cooling Capacity 11,500 to 60,000 Btuh (3.4 to 17.6 kw) Heat

More information

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES Installation and Programming Manual Part: Building Network Interface Card 4100-6047 Product: 4100ES Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS- Follow the instructions in this installation

More information

SmartBob II SBR.1 A M1 H X X XX. Base. Mounting Plate. Cable. Heater. Probe

SmartBob II SBR.1 A M1 H X X XX. Base. Mounting Plate. Cable. Heater. Probe SmartBob II Base Mark X if none Sample Sample SBR.1 A 1 035 M1 H X X XX Cable Probe Mounting Plate Heater Cable Length (begin with 0 if less than 100 ft.) Entered in feet up to 150 feet Cable Type 1: C1

More information

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator. Technical Information and Diagnostic Guide for SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator. This guide will assist you in becoming more

More information

Switch Installation. Preparing for Installation. Warnings CHAPTER

Switch Installation. Preparing for Installation. Warnings CHAPTER CHAPTER This chapter describes how to start your switch and how to interpret the power-on self-test (POST) that ensures proper operation. It also describes how to install the switch. Read the topics and

More information

PowerCommand iwatch Wireless

PowerCommand iwatch Wireless PowerCommand iwatch Wireless Description The PowerCommand iwatch Wireless remote monitoring system provides a simple, inexpensive method for remotely monitoring gensets. The monitor communicates with a

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

NITE SSI Service Parts List NITE Tech Support Line #

NITE SSI Service Parts List NITE Tech Support Line # NITE SSI Service Parts List Changes in Red X = Obsolete P/N S = Supersedes in place of original P/N R = Replaced by P/N U = Use up and obsolete = Current/Original P/N Page 1 of 19 Product Description NITE

More information

KE2 Low Temp+Defrost (pn 20903) Quick Start Guide

KE2 Low Temp+Defrost (pn 20903) Quick Start Guide KE2 Low Temp+Defrost (pn 20903) Quick & Easy Remote Communication, Control & Alarming when used with the KE2 LDA Q.3.29 (Q.1.29) May 2017 This reference should remain on site with the installed KE2 Low

More information

Product Guide: Series III Pump Control Board Set (RoHS)

Product Guide: Series III Pump Control Board Set (RoHS) revised 04/08/10 Description: The Series III Pump Control Board Set provides motor drive and pump control for a wide assortment of pumps from Scientific Systems, Inc. The assembly consists of two circuit

More information

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY TECHNICAL SPECIFICATIONS GQ6SD Series Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units The GQ6 Series single packaged units are high efficiency self contained cooling and heating units that can

More information

CHP

CHP Packaged Unit Heat Pump CHP16-024-030-036-048-060 2-5 Ton Cooling 23,000-57,500 Btuh Heating 12,800-85,300 Btuh (5-25 kw) Optional Electric Heating FEATURES Designed for outdoor rooftop or ground level

More information

Gen INSTALLATION MANUAL

Gen INSTALLATION MANUAL Gen 2 INSTALLATION MANUAL READ THIS FIRST Installation of this system should be carried out by qualified persons familiar with the general installation of law enforcement electronics commonly installed

More information

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN Hardware Installation Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN Hardware Installation Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN February 2004 CNT-SVN02B-EN Tracer AH541

More information

PRELIMINARY COMPEX SYSTEMS

PRELIMINARY COMPEX SYSTEMS Multi-function IPQ4019 Embedded Board with on-board Wireless 710MHz CPU / 2x GE Port / Dual Band / 802.11ac Wave 2 Model: WPJ419 7A01 Specifications Chipset Reference Design System Memory NOR Flash Wireless

More information

ATevo SERIES BATTERY CHARGER

ATevo SERIES BATTERY CHARGER PRODUCT OVERVIEW NEXT GENERATION NEW FEATURES: Interactive LCD display Intelligent self diagnostics NERC Compliant ATevo Battery Charger is the next generation SCR-based utility battery charger. The innovative

More information

IVTM Installation Manual

IVTM Installation Manual Integrated Vehicle Tire Pressure Monitoring IVTM Installation Manual 2nd edition Copyright WABCO 2006 Vehicle Control Systems An American Standard Company The right of amendment is reserved Version 002/06.06(us)

More information

L5000 Plus. Installation & Setup Guide

L5000 Plus. Installation & Setup Guide L5000 Plus Page 1 of 16 JDE1945 IssB s1 May 2009 Contents Description Page Safety... 3 Installation Standards 4 Specification. 4 Installation Procedure Pump Box. 6 Auxiliary Pump Boxes... 7 Connecting

More information

HS22 Bulletin # November 1992 Supersedes September 1990

HS22 Bulletin # November 1992 Supersedes September 1990 ENGINEERING DATA CANADIAN EDITION FEATURES Application The HS22 series condensing units feature extra high efficiency with minimum operating sound levels. Units have seasonal energy efficiency ratings

More information

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 INTRODUCTION The Aquavar Intelligent Pump Controller from utilizes an all new Aquavar platform, and combines it with over 20 years of

More information

AT30 SERIES BATTERY CHARGER

AT30 SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO CONTROL & OPERATING

More information

R-4500 Rooftop Condenser (45,000 BTU) R-6160 Rooftop Condenser (24,000 BTU) RED DOT UNITS CONDENSERS

R-4500 Rooftop Condenser (45,000 BTU) R-6160 Rooftop Condenser (24,000 BTU) RED DOT UNITS CONDENSERS RED DOT UNITS R-4500 Rooftop (45,000 BTU) FIRETRUCKS CRASH & RESCUE VEHICLES DUAL EVAPORATORS The R-4500 offers amazing performance for a light weight dual fan power condenser. Its high capacity gives

More information

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

ZIP Economizer Fault Detection and Diagnostics (FDD) Table Fault Detection and Diagnostics (FDD) Table Fault Detection Problem Diagnostic ction (in addition to alarm stored / transmitted) Potential Cause C Fault Code OT sensor predetermined range O damper returns

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

TOP-MOUNT REFRIGERATOR. Frigidaire P.O. BOX 8020 CHARLOTTE, NC Model No. FFTR18G2Q

TOP-MOUNT REFRIGERATOR. Frigidaire P.O. BOX 8020 CHARLOTTE, NC Model No. FFTR18G2Q Product No. S1 W1 Series R134a R134a Color stainless white Volts 115V 115V Wiring Diagram A01475501 A01475501 Owner's Guide 807332458 807876505 Market North America North America Energy Guide 807332458

More information

SecureUPS On-Line 120V AC Output, 1300VA

SecureUPS On-Line 120V AC Output, 1300VA SecureUPS On-Line 120V AC Output, 1300VA Trusted Power Protection Solution for Intelligent Transportation Systems (ITS) Challenges Intelligent transportation systems (ITS) are using innovative traffic

More information

MIMOJunior MMJ543 WIRELESS 300Mbps OUTDOOR Access Point Built in 13dBi 5GHz DUAL POLARIZATION ANTENNA or 8dBi 2.4GHz DUAL POLARIZATION ANTENNA

MIMOJunior MMJ543 WIRELESS 300Mbps OUTDOOR Access Point Built in 13dBi 5GHz DUAL POLARIZATION ANTENNA or 8dBi 2.4GHz DUAL POLARIZATION ANTENNA product datasheet Package Solution MIMOJunior MMJ543 WIRELESS 300Mbps OUTDOOR Access Point Built in 13dBi 5GHz DUAL POLARIZATION ANTENNA or 8dBi 2.4GHz DUAL POLARIZATION ANTENNA Features MIPS 24K-family

More information

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine Introduction An ISO 9001:2008 Registered Company ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown 2014-2016 Isuzu NPR 6.0L Gasoline Engine Contact InterMotive for additional vehicle applications

More information

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate,

More information

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS 1 Catalog KM-MCD-0818A Replaces KM-CSA-101A, KM-DSA-101A, KM-MSA-1213A, KM-CSE-101A and KM-MSE-101A DSA, CSA, MSA, CSE, AND MSE SERIES MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS MEDIUM

More information

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

GUIDE SPECIFICATIONS CE Series Two Stage R-410A GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall

More information

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q6SD Series Single Packaged Heat Pump, Single Phase Q6SD-13 SEER, R-410A 2-5 Ton Units Cooling: 22,800 to 58,500 Btuh Heating: 22,800 to 58,500 Btuh The Q6 Series single packaged

More information

INTECH Micro 2300-RTD6

INTECH Micro 2300-RTD6 INTECH Micro 2300-RTD6 6 Channel RTD Input Station Overview. The Intech Micro 2300 Series is a system of modular I/O Remote Stations, that add an even lower cost option to Intech s already extensive intelligent

More information

POWERCOMMAND CLOUD REMOTE MONITORING SYSTEM

POWERCOMMAND CLOUD REMOTE MONITORING SYSTEM Specification sheet POWERCOMMAND CLOUD REMOTE MONITORING SYSTEM Cummins Digital Solutions will provide customers with the ability to manage their power system assets, globally Description The PowerCommand

More information

The Power Systems Industry Experts. Installation Instructions. PT100 Stationary Generator Monitoring System

The Power Systems Industry Experts. Installation Instructions. PT100 Stationary Generator Monitoring System The Power Systems Industry Experts Installation Instructions PT100 Stationary Generator Monitoring System PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLATION Planning the Installation The monitoring unit

More information

Installation and Operation Guide

Installation and Operation Guide Bus-Scan CR2 RF Installation and Operation Guide All Content and Information are Copyright 2018 Robotics Technologies, Inc. Features and Information are subject to change without notice. All Rights Reserved.

More information

WirelessAIR Advanced Integrated Remote

WirelessAIR Advanced Integrated Remote Advanced Integrated Remote Gen 3 Kit 72000 Automatic Leveling Digital On-Board Compressor System MN-772 (021112) ECR 7233 INSTALLATION GUIDE For maximum effectiveness and safety, please read these instructions

More information

AT EVO SERIES BATTERY CHARGER

AT EVO SERIES BATTERY CHARGER STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation

More information

An ISO 9001:2008 Registered Company

An ISO 9001:2008 Registered Company An ISO 9001:2008 Registered Company CVC501-A HVAC & Fast Idle CAN Vehicle Controller CVC502-A HVAC Control without Fast Idle 2011-2016 Ford F250-F550 (CVC501/502-A) 2017 Ford F-250-F550 (B-CVC501/502-A)

More information

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized

More information

High Profile Evaporator

High Profile Evaporator PRODUCT DATA & INSTALLATION Bulletin K30-KHPE-PDI-3 Part # 1081588 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile orator Low & Medium Temperature Electric

More information

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel 18/10 AISI 304 both in- and outside. All the internal corners

More information

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet SOLAR SMART 12/24V 20Amp MPPT Solar Charge controller with Ethernet Embedded web pages, SNMP support, output port for external Relay board and GSM SMS unit port USER MANUAL PLEASE READ THIS MANUAL CAREFULLY

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: Dec., 2015 Version: 1.1 2 3 What s in the Box CONTENT 2 Screws & Anchors 2 Screwdriver 4 Diode Contents What s in the Box...2 Optional accessories...4

More information

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7 Features User Accessible Memory for Test Configuration Management ±0.05% FS System Accuracy EU Throughput Rates of 500 Hz Auto-Negotiating 10/100 BaseT Ethernet with TCP & UDP Protocol Pressure Ranges

More information

Orion BMS Purchasing Guide Rev. 1.2

Orion BMS Purchasing Guide Rev. 1.2 www.orionbms.com Orion BMS Purchasing Guide Rev. 1.2 Main Components... 2 Orion BMS Unit... 2 Current Sensor... 4 Thermistors... 5 CANdapter... 6 Wiring Harnesses... 7 Cell voltage tap wiring harnesses...

More information

SUPER DUTY THE AFFORDABLE SOLUTION 8685 Station Street, P.O. Box 90, Mentor, OH 44061-0090 USA P: +1-440-255-9333 F: +1-440-255-6427 E: solutions@lintern.com www.lintern.com SUPER DUTY CONDENSER TOTAL

More information

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic CONTENT 1. SUMMARY... 4 2. PERFORMANCE AND CHARACTERISTICS... 4 3. SPECIFICATIONS... 5 4. OPERATION... 6 5. PROTECTION...

More information

ELECTRICAL SYSTEM RP-7

ELECTRICAL SYSTEM RP-7 ELECTRICAL SYSTEM RP-7 This section of the manual does not include integral electrical components of the engine. Refer to section Engine RP-1 for details. This section of the manual is divided into three

More information

EcoNet and Flash Codes

EcoNet and Flash Codes The error codes below will be displayed at the EcoNet Control Center under Service window / Current Faults or in the Fault History and will be time & date stamped. VSODC (Variable Speed Outdoor Unit Control

More information

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications An ISO 9001:2008 Registered Company System Operation Idle Timer Controller - ITC805 2013-2018 Freightliner MT45 Contact InterMotive for additional vehicle applications The ITC805 system shuts down idling

More information

Low Profile Unit Cooler

Low Profile Unit Cooler Low Profile Unit Cooler Publication No. 100.13 January, 2004 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk -

More information

Electronic Refrigerator Diagnostics

Electronic Refrigerator Diagnostics Electronic Refrigerator Diagnostics IMPORTANT SAFETY NOTICE The information in this presentation is intended for use by individuals possessing adequate backgrounds of electrical, electronic, & mechanical

More information

Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN

Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN > > Used for small to medium Freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment

More information

High Profile Evaporator

High Profile Evaporator High Profile orator PRODUCT DATA & INSTALLATION Bulletin K30-KHPHG-PDI-3 Part # 1081591 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Low & Medium Hot Gas Defrost

More information

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004 U00X ULTRASONIC LEVEL SWITCH INSTALLATION AND OPERATIONS MANUAL Ultrasonic Liquid Level Switches For Non-Hazardous Locations For Models: U002, U003 & U004 READ THIS MANUAL PRIOR TO INSTALLATION This manual

More information

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS GP5RD Series Single Packaged Air Conditioner, Single Phase GP5RD-13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 60,000 Btuh The GP5 Series single packaged air conditioners

More information

LaserJet 2200d. HP Parts Reference Guide. 250 Sheet Feeder Assembly. 250 Sheet Feeder Drive. Bushing. Cable. Connector. Cover. Feed Assembly.

LaserJet 2200d. HP Parts Reference Guide. 250 Sheet Feeder Assembly. 250 Sheet Feeder Drive. Bushing. Cable. Connector. Cover. Feed Assembly. HP Parts Reference Guide www.hp.comgohpparts 250 Sheet Feeder Assembly Bushing 1 RB2-2895-000CN Shaft bushingretainer - Pickup roller support bushing on right side - Pickup Roller Right Side Support Bushing

More information