1 Issue 2.2 Mar 2017 MC200CAB/4 Integral Version Industrial & Commercial Heating Systems. Setting Instructions WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Reset from Lockout is by a switched Neutral GB & IE H E A T I N G / / V E N T I L A T I O N / / A I R C O N D I T I O N I N G

2 Se ng Instruc ons CONTENTS Section Page 1 General 2 2 Engineer Controls 3 3 Temperature Sensors 5 4 Outputs 6 5 Handover 6 6 Terminal Locations 6 7 Terminal Specifications 7 8 Short List of Parts 7 1 General 1.1. Sensor Sensor Options The MC200 fitted into the heater has an integral sensor however the following options are available if deemed necessary. 1) The integral sensor may be removed and replaced by either a room type remote sensor or duct type remote sensor. Both are available from Powrmatic Ltd. Alternative types must not be used. 2) A second sensor by be used in addition to the integral sensor in which case the controlling temperature will be an average of the two measured values. 3) A switch may be used in addition to the integral sensor or a single remote sensor. This could, for example, allow additional control of the heating depending on whether a loading bay door is open or closed. Fitting Additional Sensor or Switch Room Type Sensor The sensor should be sited no further than 100m from the main unit. Siting of the sensor is important in that it must be fitted where the temperature will be generally representative of the area to be heated. It should be installed 1.7m above floor level and away from draughty areas or areas subjected to direct heat from sunlight, radiators etc. The sensor MUST NOT be sited in areas of high electromagnetic fields, i.e. distribution boards, transformers or heavy duty supply cables. Fixing Remove cover and offer the sensor base plate up to the intended mounting position and mark two fixing holes. Fix sensor base plate to the wall. Complete wiring and refix the cover. Room and Duct Type Sensors WARNING - SENSOR WIRING Sensor cable must be screened two core and a minimum of 0.6mm² if solid and 7 x 0.2mm² if multistrand. The screen must be grounded only at the MC200. Wiring for the temperature sensor MUST BE RUN SEPARATELY and apart from ALL other wiring. Failure to regard this instruction may cause the MC200 to malfunction and may render it faulty. Under no circumstances must voltage be applied to the sensor connections - see Section 9 regarding alternative sensor inputs. Switch Wiring Wiring between Terminals Com & SEN2 and a switch can be completed in ordinary 2 core cable e.g. 7 x 0.2mm² multistrand Basic MC200 settings For information on the basic MC200 settings e.g. Date, Time, Key Pad Layout, Time Switch Programming etc refer to the MC200 Users Instructions supplied with this unit. Page 2 MC200/V4 Integral Version - Se ngs Instruc ons Issue 2.2 Mar 2017

3 2 Engineer Controls The engineer menu is enabled by entering the engineer pass-code at the Password menu option. In order to ensure that the engineer code and the user code are always distinct, the engineer code is a 3-digit number and one asterisk. See label on the reverse of the terminal cover. Once the engineer code has been correctly entered no user or engineer codes will be required for a period of 1 hour. An additional menu option then becomes visible and pressing will lead to the engineer s sub-menu. Press or to move through the options. At any point, press X to exit from the engineer sub-menu back to the User menu. Many of the Engineer settings are determined by the installed equipment however others will be to the end users preferences. The latter should be left at default settings if there is no end user when the control is being commissioned. If the Users menu is password protected the Engineer code permits access to both the Engineer menu and the User menu Engineer Settings Burner type (On/Off, High-Low, Modulating) Defines the type of controlled burner. Burner High Rating (kw) Defines the high heat input (in kw) of the controlled burner for cost calculations. Burner Low Rating (kw) Defines the Low heat input (in kw) of the controlled burner for cost calculations. Note: This menu item only appears when Hi/Lo burner type has been selected. Test Burners Facilitates direct testing of the controlled burner(s) irrespective of current control settings, times etc. High-Low differential ( C) Sets the temperature difference between the Hi and Lo stages of Hi/Lo burners Note: This menu item only appears when Hi/Lo burner type has been selected. Modulation offset ( C) Sets the temperature at which the 0-10V signal will be 10V and the burner will be at High Fire. Note: This menu item only appears when Modulating burner type has been selected. Auto reset (On/Off) Sets whether the control will complete an automatic reset of lockout, If lockout signal is not removed by a manual reset the MC200 will initiate an automatic reset 30 minutes after the lockout signal and then once every 24hrs. Reset Time (1 second, 3 seconds, 5 seconds) Sets how long the lockout reset terminal is connected to neutral when the reset button is pressed. Sensor 2 Function (Not Used, Remote, Close = off, Close = on, Open = off, Open = on) Sets the function of sensor 2 input Trim Temperature ( C) A temperature offset can be entered here to adjust the displayed temperature to agree with the sensor temperature. Range of adjustment -5 C to +5 C Set User Temperature minimum ( C) Sets the minimum temperature that the User can select. Default 15 C, can be reduced to 10 C. Set User Temperature maximum ( C) Sets the maximum temperature that the User can select. Default 30 C, can be increased to 60 C. Temp Adjust ( C) Sets C that User can temporarily adjust the current set point up or down. Default 3 C, Range is 0.5 C to 30 C. Constant Fan (Off/Auto/Const/On) Sets the mode of Fan operation between OFF (For Summer operation - fan only operates when Fan button is pressed and will remain on until Fan button is pressed again or until midnight), Auto (fan runs at dictate of fan thermostat on heater), Const (fan runs continuously when timer is in Heat On state), or ON (fan runs 24/7). Default setting is OFF Frost/Setback (On/Off) Sets frost protection/night setback to active or inactive. Hysteresis ( C) Switching differential band. Default 0.5 C, can be increased to 5 C. On the default setting, the heat demand will switch on & off at 0.5 of the target temperature. i.e. target temperature is 20 C, the heater will turn OFF at 20.5 C and turn back ON again once the temperature falls below 19.5 C. If the Hysteresis is set to for example 3 C and the target temperature is 20 C, the heating will turn OFF at 20.5 C and turn back ON again once the temperature has fallen below 17.0 C. (-3 of target temperature). Setback Temperature ( C) Sets the frost protection/night setback temperature value. Optimum Start (On/Off) Sets whether Optimum Start is active Optimum Stop ( C) Sets the Optimum Stop temperature Service Date Allows a service date to be set Lockout Log Displays the most recent lockout time and date Clear Lockout Log If lockout log is not cleared newer events will over-write older ones. Restore Defaults Resets all parameters to factory default settings. NOTE: This action returns the unit to the main screen and also clears the Engineers password. MC200/V4 Integral Version - Se ngs Instruc ons Issue 2.2 Mar 2017 Page 3

4 2.2. Engineer Settings Menu flow chart At the normal display screen press Back to access the Password screen Password **** The first * will be pulsing. Press - or + to enter 5. Press to go to the next digit and repeat until the password is entered. Press and the screen will show VALID. Press Back. Note: If - or + is pressed when the last * is pulsing it is not possible to enter *. Press (the display will show Password FAIL), press X and then Back to restart the entry process. Back Engineer menu Press to access Engineers menu. Burner: On-Off Default Setting: On - Off Set to: Press - or + to toggle through modes. Discard (X) or save ( ) changes. BurnerHi 0120 kw The first digit will be pulsing. Press - or + to set this digit to agree with first digit of burner maximum input rating (in kw). Press to go to the next digit and repeat until input rating is entered. Press. If the burner type has been set to High-Low press and the next screen will allow entry of the burner minimum input rating. BurnerLo 0120 kw Only present if a Hi/Lo burner is selected. The first digit will be pulsing. Press - or + to set this digit to agree with first digit of burner minimum input rating (in kw). Press to go to the next digit and repeat until input rating is entered. Press. Burner Test Press to test the burner. Pressing - or + will toggle between modes. Available modes are determined by the type of burner entered. For modulating burners the 0-10V out put can be changed in 1V steps. Press X to exit. Mod Offset 6.0 C Default Setting: 6.0 C Set to: Only present if a modulating burner is selected. Press - or + to decrease or increase the value. Discard (X) or save ( ) changes. Auto Reset OFF Default Setting: OFF Set to: Press - or + to toggle through modes (ON, OFF). Discard (X) or save ( ) changes. Reset time 1 sec Default Setting: 1 Set to: Press - or + to toggle through available times (1, 3, 5secs). Discard (X) or save ( ) changes. Snsr2: Not used Default Setting: Not used Set to: Press - or + to toggle through available options (Not Used, Remote, Close = off, Close = on, Open = off, Open = on). Discard (X) or save ) changes. Trim temp +0.0 C Default Setting: +0.0 C Set to: Press - or + to decrease or increase the value (-5 to +5 C). Discard (X) or save ( ) changes. User TempMin 15.0 Default Setting: 15.0 C Set to: Press - or + to decrease or increase the value (10 to 20 C). Discard (X) or save ( ) changes. Page 4 MC200/V4 Integral Version - Se ngs Instruc ons Issue 2.2 Mar 2017

5 User TempMax 30.0 Default Setting: 30.0 C Set to: Press - or + to decrease or increase the value (20 to 60 C). Discard (X) or save ( ) changes. Temp Adjust 3.0 Default Setting: 3.0 C Set to: Press - or + to decrease or increase the value (0.5 to 6 C). Discard (X) or save ( ) changes. ConstFan: Auto Default Setting: OFF Set to: Press - or + to toggle through modes (Auto, Const, On, Off). Discard (X) or save ( ) changes. Frost/setback OFF Default Setting: OFF Set to: Press - or + to toggle through modes (OFF, ON). Discard (X) or save ( ) changes. SetbackTemp 5.0 Default Setting: 5.0 C Set to: Press - or + to decrease or increase the value (1 C to 15 C). Discard (X) or save ( ) changes. Hysteresis 0.5 C Default Setting: 0.5 C Set to: Press - or + to decrease or increase the value (0.5 C to 5 C). Discard (X) or save ( ) changes. OptimumStart OFF Default Setting: OFF Set to: Press - or + to toggle through modes (OFF, ON). Discard (X) or save ( ) changes. Opt Stop 3.0 C Default Setting: 0.0 C Set to: Press - or + to decrease or increase the value (0.5 C to 6.0 C). Discard (X) or save ( ) changes. Service date Press OK to enter a service date. Pressing - or + will decrease or increase the pulsing digits. Press or to select figure to change, figure will pulse. Discard (X) or save ( ) changes. Lockout Log Press to view lock out log. Press or to clear log. Press or X as required. Restore Defaults Warning: This action is immediate and cannot be reversed. Press to restore defaults. Note: This action returns the unit to the main screen and also clears the Engineers password. MC200/V4 Integral Version - Se ngs Instruc ons Issue 2.2 Mar 2017 Page 5

6 3 Temperature Sensors Options are Default internal sensor Terminals Sen1 & Com Remote sensor Terminals Sen1 & Com Internal + Remote Terminals Sen1, Com & In2 Remote + Remote Terminals Sen1, Com & In2 The remote sensor may be either room or duct type. The second sensor input (Terminals Com & In2) can also accept a volt free switch input i.e. a volt free switch is connected across Terminals Com & In2 to facilitate additional functions as below Sensor terminal options are (It is assumed that Sensor 1 is always fitted) 1) In2: Not used The sensor 2 terminals are ignored 2) In2: Remote A temperature sensor is connected 3) In2: Close = off A switch is fitted. When it closes, heating goes off 4) In2: Close = on A switch is fitted. When it closes, heating goes on 5) In2: Open = off A switch is fitted. When it opens, heating goes off 6) In2: Open = on A switch is fitted. When it opens, heating goes on Heating will be overridden by the switch operation during programmed heating times. Heating control returns to normal when the switch reverts, or when the programmed control period ends. The switched control does not occur while heating is turned on due to manual override in non-programmed times, and does not occur during the manually-selected extension time at the end of a programmed control period. If heating has been manually overridden to be off during a programmed heating period, the switched control cannot bring on the heating. The Heat on option means that heat will be turned fully on by the switch. For high-low burners, the high and low relays will be on, and for modulating burners, the control output will be 10v. Cost logging operates as usual. During these switch control periods the burn time is recorded at the maximum rate. If the sensor goes open-circuit (if either of the sensors goes open-circuit where two are fitted), the Fault LED will flash. The LCD display will show sensor failed. NOTE: The earlier MC100 sensor cannot be used with the MC200/V3 and the MC200/V3 sensor cannot be used with the MC Outputs 4.1. Single burner When configured for a single burner heater, the Low heat relay (Terminal Heat Lo ) operates when the sensor temperature is below the set temperature Two-stage When configured for a two-stage burner heater, the Low heat relay (Terminal Heat Lo ) operates when the sensor temperature is below the set temperature i.e. as ON/OFF. The High heat relay (Terminals Heat In Hi and Heat Out Hi ) operates when the sensor temperature is below the set temperature by more than the number of degrees set in the Hi/Lo differential parameter to switch from low fire to high fire e.g. If the set temperatures is 18 C and the Hi/Lo differential is set to 4 C the high heat relay will operate at <14 C. The Low Level relay remains operated while the High heat relay is operated Modulating The 0-10Vdc output stays at zero and the Low heat relay (Terminal Heat Lo ) will remain de-energized while the sensor temperature is at or above the set temperature. Below the set temperature, the Low heat relay (Terminal Heat Lo ) will operate and the modulating output voltage (Terminals 0-10v+ and 0-10v-) increases, reaching 10v when the sensor temperature falls to the threshold set i.e 0V at low fire, 10V at High Fire. 5 Handover Demonstrate the setting up and operation of the control to the end user. Leave the User Instructions with the end user. Page 6 MC200/V4 Integral Version - Se ngs Instruc ons Issue 2.2 Mar 2017

7 6 Terminal Locations 6.1. Front View 6.2. Rear View SEN1 COM SEN2 V+ 0V NOTE: first group of terminals are ¼ tabs at the rear of the printed circuit board behind the facia plate panel 7 Terminal Layout Terminal Type Function RESET Output ( 3 ) Burner lockout reset LOCKOUT Input ( 3 ) Burner lockout indication N Input Electrical Supply E Earth Electrical Supply L Input (230V~) Electrical Supply FAN Out Output (230V~) Fan relay contact HEAT Lo Input (Volt free 2 ) Heat/Lo relay contact HEAT Lo Out Output (230V 4 or Volt free 2 MC200/4 ) Heat/Lo relay contact HEAT Hi In Input (Volt free 2 Fuelsaver ) Heat Hi relay contact HEAT Hi Out Output (Volt free 2 ) Heat Hi relay contact Sen1 Input (no voltage 1 ) Connection for prime sensor (not polarity sensitive) COM Input (no voltage 1 ) Common connection for sensors and/or auxiliary switch Sen 2 Input (no voltage 1 ) Connection for 2nd sensor (averaging) or for auxiliary switch V + Output Positive rail of 0-10V modulating control voltage 0V Output Negative rail of 0-10V modulating control voltage Notes: 1 - Voltage must not be applied to the sensor terminals. If a switch is fitted across COM and IN 2 it must be volt free. 2 - If an output voltage is required (230V, 24V, 10V etc) the appropriate voltage must be applied to the corresponding input terminal. 3 - Not used on CPx heaters. 4 - Mains output voltage direct from board unless link is cut for volt free applications (refer note.2). 8 Short List of Parts RESET LOCK OUT N E L FAN out HEAT Lo In HEAT Lo out HEAT Hi HEAT HI Sen 1 COM Sen v+ 0-10v- MC200/V4 Integral Version - Se ngs Instruc ons Issue 2.2 Mar 2017 Page 7

8 8 Short List of Parts Item Powrmatic Part # Complete unit MC200CAB/4 Internal sensor bead Remote sensor (air temperature) Black bulb sensor (radiant temperature) Duct Sensor Set up instructional videos now available on our website/youtube:- More information is available from our web site on:- HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax: Every effort is made to ensure accuracy at time of going to press. However as part of our policy of continued product improvement, we reserve the right to alter specification without prior notice. Page 8 MC200/V4 Integral Version - Se ngs Instruc ons Issue 2.2 Mar 2017

ECONOMISER SERIES E2T USER MANUAL

ECONOMISER SERIES E2T USER MANUAL TURBO S.R.L. Electronic Control Systems for Dust Collectors e-mail: info@turbocontrols.it web: www.turbocontrols.it TEL. ++39 (0)362 574024 FAX ++39 (0)362 574092 ECONOMISER SERIES E2T USER MANUAL 24/06/2014

More information

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient

More information

PROPORTIONAL BAND ZERO ENERGY BAND DEFINITION S1 S2

PROPORTIONAL BAND ZERO ENERGY BAND DEFINITION S1 S2 Honeywell T0C INDIVIDUAL ROOM TEMPERATURE CONTROLLER INSTALLATION GUIDE Cover removal Mounting T0C 00-00 R Wiring T0C.mm (max) Remote Temperature Sensor Screen wire 0 Connect screen wire to terminal or

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02

OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02 OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02 1. INTRODUCTION 2. SAFETY INSTRUCTIONS 3. SPECIFICATION 4. OPERATING INSTRUCTIONS AND CONTROL FUNCTIONS 5. SET UP PROCEDURE 6. CONNECTIONS

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

SE8300 Series Installation Guide 24 Vac Low Voltage

SE8300 Series Installation Guide 24 Vac Low Voltage Installation Guide 24 Vac Voltage mercial and Hotel/Lodging HVAC Fan Coil Applications CONTENTS Installation 2 Configurable BI/UI Universal Inputs Overview 3 Setup Screen Display 3 Terminal Identification

More information

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down DC-DC Converter has a digitally adjustable output in 0.2V increments. This

More information

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide Introduction: Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide The NCC-002 is capable of controlling two stages of progressive nitrous and fuel. If the NCC-002 is configured only for nitrous,

More information

Installation Instructions & Users Manual

Installation Instructions & Users Manual Installation Instructions & Users Manual UTILITY/ BUILDING INPUT 120 VAC ( OPTION) 15-20A N L CONTROL BOARD G SECURITY LIGHTING POWER SUPPLY (OPTION) CHARGER- POWER SUPPLY ASSBY XFMR (OPTION) CBM MODEL

More information

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

Deep Sea Electronics Plc

Deep Sea Electronics Plc Deep Sea Electronics Plc 5120 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL Author: Anthony Manton Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH England Tel: +44 (0) 1723

More information

Quick Setup Guide for IntelliAg Model YP Air Pro

Quick Setup Guide for IntelliAg Model YP Air Pro STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference

More information

REVISION HISTORY REVISION HISTORY

REVISION HISTORY REVISION HISTORY FILTER CONTROLLER REVISION HISTORY Filter Flush Controller forms part of the Netafim range of filtration controllers all designed to make filteration more reliable and economical.. Contact any of the Netafim

More information

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72

USER GUIDE Digital Thermostat GUIDE D UTILISATION Thermostat digital Bedienungsanleitung Termostato digital 50-72 BT D-01 1 2 USER GUIDE GB Digital Thermostat 4-25 GUIDE D UTILISATION F Thermostat digital 26-49 Bedienungsanleitung D Termostato digital 50-72 GUÍA DE USUARIO ES Termostato digital 74-97 GUIA DO UTILIZADOR

More information

CM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM707 (UK Version) PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET The CM707 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It

More information

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets Art. nr. 40200261 OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets WHISPERPOWER BV Kelvinlaan 82 9207 JB Drachten Netherlands Tel.: +31-512-571550 Fax.: +31-512-571599

More information

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine Introduction An ISO 9001:2008 Registered Company ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown 2014-2016 Isuzu NPR 6.0L Gasoline Engine Contact InterMotive for additional vehicle applications

More information

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features Product Guide ALC-PRM-VFC Ceiling Mounted Photocell Overview The ALC-PRM-VFC photocell will turn lighting on when the ambient light falls below a preset level. The lighting will then be turned off when

More information

M440 MOTOR PROTECTION, EARTH FAULT LOCKOUT & MANAGEMENT RELAY VERSION 3.5 NINGI SERVICES (PTY) LTD

M440 MOTOR PROTECTION, EARTH FAULT LOCKOUT & MANAGEMENT RELAY VERSION 3.5 NINGI SERVICES (PTY) LTD M440 MOTOR PROTECTION, EARTH FAULT LOCKOUT & MANAGEMENT RELAY VERSION 3.5 NINGI SERVICES (PTY) LTD TOLL FREE 0800 000 400 TEL 013 692 3372 FAX 013 692 3392 CELL 082 556 7682 1 Presenting the UM440U Motor

More information

Modulating Furnace Information. Warning on Meter Setting - Read First!

Modulating Furnace Information. Warning on Meter Setting - Read First! Modulating Furnace Information Pressure Transducer Pressure DC Volts 0.00" 0.25 0.20" 0.63 0.25" 0.72 0.30" 0.82 0.35" 0.91 0.40" 1.00 0.45" 1.09 0.50" 1.19 0.55" 1.28 0.60" 1.38 0.65" 1.47 0.70" 1.56

More information

CM707 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM707 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM707 PROGRAMMABLE THERMOSTAT PRODUCT SPECIFICATION SHEET The CM707 thermostat is designed to provide automatic time and temperature control of heating systems in villas and apartments. It can be used

More information

Section 3 Technical Information

Section 3 Technical Information Section 3 Technical Information In this Module: Engine identification Modes of operation Battery charging and heat manage operation Service and repair procedures Maintenance requirements Engine Identification

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power. Technical Information Double Oven Dual Fuel Range JDR8895AAB/S/W Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.

More information

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Sheet 1 of 5 Order Number Serial Number PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Issue Date Level B 27/05/1999 Initial issue. Summary of changes Due to RMS continuous product improvement policy

More information

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL SMARTGEN ELECTRONICS Smartgen Electronic Equipment Co., Ltd No.12 Dongqing Street Zhengzhou Henan Province P.R.China Tel : (0086)-371-67992951

More information

LCD EWP /FAN DIGITAL CONTROLLER Installation Instructions

LCD EWP /FAN DIGITAL CONTROLLER Installation Instructions 77 Taras Avenue P.O. Box 363 Altona North Vic 3025 Australia Phone: +61(0)3 9369 1234 Fax: +61(0)3 9369 3456 Email: info@daviescraig.com.au Web: www.daviescraig.com.au LCD EWP /FAN DIGITAL CONTROLLER Installation

More information

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology HGM1780 Automatic Genset Controller USER MANUAL Smartgen Technology Smartgen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou Henan Province P. R. China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951

More information

Rally computer 3 Rally computer 3.GPS *

Rally computer 3 Rally computer 3.GPS * Rally computer 3 Rally computer 3.GPS * User manual. Installation and configuration instructions. (with links to video instructions online at : www.rallycomputer.com ) * Content marked applies only to

More information

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER Cautions WARNING: EXPLOSION HAZARD- -DO NOT SERVICE UNLESS AREA IS KNOWN TO BE NON- HAZARDOUS -DO NOT OPEN WHEN ENERGIZED EXPLOSION HAZARD- -SUBSTITUTION

More information

Electric Stone Hearth Oven

Electric Stone Hearth Oven Beech Electric Oven Manual_R5.doc Page 1 of 12 2012-05-08 (C) Electric Stone Hearth Oven The Beech Ovens electric Stone Hearth oven has been developed to include an in-floor electric element and a smooth

More information

Generator Start Control Module

Generator Start Control Module Generator Start Control Module Part# GSCM-mini-i ATKINSON ELECTRONICS, INC. 14 West Vine Street Murray, Utah 84107 Contact cbdsales@atkinsonel.com for the proper hookup diagram. Please include the generator

More information

SPEEDRIVE INSTRUCTIONS MANUAL

SPEEDRIVE INSTRUCTIONS MANUAL EN SPEEDRIVE INSTRUCTIONS MANUAL Safety warning. The following symbols shown beside a paragraph represent danger warnings associated to the failure to comply with the corresponding instructions. DANGER!

More information

TC62D Installation Instructions

TC62D Installation Instructions TC62D Installation Instructions January 2007 This TC62D has a return water low temperature limit option. Using the low limit precludes using a room sensor because both sensors plug into the same port.

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power. Technical Information Gas Slide-In Range JGS8750ADB/S/W JGS8850ADB/Q/S/W Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this

More information

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007) Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions

More information

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#3

Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) r#3 Operators Manual SUREFIRE II Single Phase PDI - SLR (24VDC, 115VAC & 230VAC) 36412 r#3 Contents Precautions & Symbols...2 Manufacturer s Statement...2 General...2 Features...2 Operation...3-4 Technical

More information

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro STEP 1: Pre-Programming Preparation: The Quick Guide assumes the Virtual Terminal, Master Switch, Working Set Master, Working Set Member, and all sensors have been connected and properly installed. Reference

More information

Vission 20/20 micro-controller. Operation and service manual

Vission 20/20 micro-controller. Operation and service manual Vission 20/20 micro-controller Operation and service manual Section Title Table of Contents Section Number How To Use This Manual...TOC-8 Section 1 Operational Flow Charts Requirements to Start Compressor...1-1

More information

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic Smartgen Electronic Equipment Co., Ltd No.28 Jinsuo Road Zhengzhou Henan Province P.R.China Tel: 0086-371-67988888/67981888 0086-371-67991553/67992951/67992952

More information

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,

More information

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches MiG2 TIME SWITCHES 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches The MiG2 series of timers are programmable 365-day time-switches, incorporating: Multiple switching times per day Single and block

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide Factory Packaged Controls OE377-26-00058 (AAON Part No. V12090) MODGAS-X Controller Table of Contents GENERAL INFORMATION... 3 Overview...3 Features...3 INSTALLATION & WIRING... 4 Supply Air Temperature

More information

MODEL MVX-2011 TANK MOUNT SPEEDOMETER/TACHOMETER

MODEL MVX-2011 TANK MOUNT SPEEDOMETER/TACHOMETER MODEL MVX-2011 TANK MOUNT SPEEDOMETER/TACHOMETER Wiring Diagram The MVX-2011 gauges will work on 2011-up Softail models with 5 gauges or 2012-up Dyna models with 5 gauges. It is a direct plug in on these

More information

TIMER INTERFACE USER MANUAL

TIMER INTERFACE USER MANUAL TIMER INTERFACE USER MANUAL Premium Efficiency Two-Speed Motor with Integrated Timer Formerly A. O. Smith Electrical Products Company A Regal Beloit Company COPYRIGHT Copyright 2011, Regal Beloit EPC,

More information

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications An ISO 9001:2008 Registered Company Idle Timer Controller - ITC515-A 2015-2018 Ford Transit Contact InterMotive for additional vehicle applications Overview The ITC515-A system will shut off gas or diesel

More information

Only use if safe to do so and at your own risk.

Only use if safe to do so and at your own risk. This product may not be suitable or safe for road usage. The owner accepts ALL responsibility for its use and installation. The product must not be used if malfunction occurs, a suspected malfunction occurs

More information

POWERLINE 2000 Energy Management System TM

POWERLINE 2000 Energy Management System TM Display Panel TM The PowerLine 00 EMS is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed in the standard main distribution

More information

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB TB6980/TB7980 1. Introduction The TB6980/TB7980 digital thermostats provide proportional plus integral individual space temperature control in zoned commercial HVAC systems such as hydronic and pressure

More information

CODE MODEL TYPE PRESS GW 605 T80

CODE MODEL TYPE PRESS GW 605 T80 Installation, use and maintenance instructions Pressure jet burner CODE MODEL TYPE 3473784 PRESS GW 605 T80 291 (2) - 08/2012 Thermal power 107 / 178-350 kw - 92.000 / 153.000-301.000 kcal/h Output 9/15-30

More information

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL AUTOMATIC FILTERS, INC. 67 S. LA CIENEGA BLVD. LOS ANGELES, CA 90034 30 839 88 800 336 94 FAX 30 839 6878 www.tekleen.com info@tekleen.com Tekleen GB6 & GB7 USERS MANUAL GB6 & GB7 USERS MANUAL AUTOMATIC

More information

Installation and Maintenancee Manual

Installation and Maintenancee Manual Installation and Maintenancee Manual Commercial Boom Gate Operator Model: GDS BOOM 4 and 6 A.B.N. 62 059 806 405 Nov 2013 Section No: CONTENTS Page Number: 1 Safety Precautions 3 2 Specifications 4 3 Mechanical

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power. Technical Information Double Oven Electric Range MER6549BAQ/W MER6769BAQ/W Due to possibility of personal injury or property damage, always contact an authorized technician to service or repair this unit.

More information

PULSE-8: MASTER PULSATION CONTROL

PULSE-8: MASTER PULSATION CONTROL PULSE-8: CONTROL Version - February 2006 For Software Version V1.02 Part Number - 39-0020 CONTROL: INDEX GOOD PRACTICE: Mains Supply. A separate mains supply and earth running directly from the consumer

More information

FOLLOW THE ARROWS. Alspa MV1000 Variable speed drive TEL: INSTALLATION QUICK START PROGRAMMING. FIRMWARE VERSION: 1.

FOLLOW THE ARROWS. Alspa MV1000 Variable speed drive TEL: INSTALLATION QUICK START PROGRAMMING. FIRMWARE VERSION: 1. FOLLOW THE ARROWS INSTALLATION DIAGSTICS SUPPORT Nos. QUICK START PROGRAMMING. FIRMWARE VERSION: 1.31 TE: User must adhere to all SAFETY AND OPERATING INSTRUCTIONS for DRIVE CONVERTERS, detailed on the

More information

CONTROLLER DIAGNOSTIC GUIDE

CONTROLLER DIAGNOSTIC GUIDE Proprietary tice: This document contains proprietary information which not to be reproduced, transferred, to other documents, disclosed to others, used for manufacturing or any other purpose without the

More information

INSTALLATION/OPERATING INSTRUCTIONS MCP

INSTALLATION/OPERATING INSTRUCTIONS MCP INSTALLATION/OPERATING INSTRUCTIONS MCP Modulating Digital Set Point Control with Boiler Output and External Activation Temperature Range -30 to 250 F (-35 to 120 C) Pressure Ranges 0-30, 0-100, 0-200PSI

More information

Generator Start Control Module

Generator Start Control Module Generator Start Control Module Part# GSCM-mini-o ATKINSON ELECTRONICS, INC. 14 West Vine Street Murray, Utah 84107 Contact cbdsales@atkinsonel.com for the proper hookup diagram. Please include the generator

More information

EXCELSIOR-HENDERSON MOTORCYCLE MANUFACTURING COMPANY 805 HANLON DRIVE BELLE PLAINE, MINNESOTA TELE: /FAX:

EXCELSIOR-HENDERSON MOTORCYCLE MANUFACTURING COMPANY 805 HANLON DRIVE BELLE PLAINE, MINNESOTA TELE: /FAX: All text, photographs, and illustrations in this handbook are based on the most current product information available at the time of publication. Product improvements or other changes may result in differences

More information

Installation Instructions

Installation Instructions F20/F25 Installation Instructions PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED Installation Precautions: Roll down window to avoid locking keys in vehicle during installation Avoid mounting components

More information

OPERATING INSTRUCTIONS ECON-M

OPERATING INSTRUCTIONS ECON-M OPERATING INSTRUCTIONS ECON-M INDEX 1.0 Introduction 2.0 Salient features, Protection & Supervision 3.0 Display/ Front Panel 4.0 Switches Description 5.0 LED Annunciations Description 6.0 Lamp Test 7.0

More information

Issue 2.0 December EPAS Midi User Manual EPAS35

Issue 2.0 December EPAS Midi User Manual EPAS35 Issue 2.0 December 2017 EPAS Midi EPAS35 CONTENTS 1 Introduction 4 1.1 What is EPAS Desktop Pro? 4 1.2 About This Manual 4 1.3 Typographical Conventions 5 1.4 Getting Technical Support 5 2 Getting Started

More information

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

User Manual. T6 Tachometer. Online:   Telephone: P.O. Box St. Petersburg, Florida 33736 User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power. Technical Information Double Oven Electric Range MER6555AAB/Q/W MER6751AAB/Q/S/W MER6755AAB/Q/S/W MER6775AAB/F/N/Q/S/W Due to possibility of personal injury or property damage, always contact an authorized

More information

320 to 327 M Series Low and Medium Voltage Motor Protection Relays

320 to 327 M Series Low and Medium Voltage Motor Protection Relays 1. Protection Features 320 to 327 M Series Low and Medium Voltage Motor Protection Relays INSTALLATION AND SETTING UP PROCEDURE Overloading (for both cyclic and sustained overload conditions) Start stall

More information

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE REV. ARS. WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE This device complies with Part 5 of the FCC rules. Operation is subject to the following conditions:. This device may not cause

More information

RDG160TU Commercial Thermostat

RDG160TU Commercial Thermostat Document No. 129-588 RDG160TU Commercial Thermostat Selecting Location Install the thermostat about 4 feet (120 cm) above the floor on an inside wall. Ensure that there is free airflow around the thermostat.

More information

SC SERIES SOLAR CONTROLLER USER MANUAL Ver 1.0

SC SERIES SOLAR CONTROLLER USER MANUAL Ver 1.0 SC SERIES SOLAR CONTROLLER USER MANUAL Ver 1.0 (for SC-2420, 2430, 2440, 2450, 2460,4840 and 4860) 1 2 Solar Controller SC series solar controller USER MANUAL Congratulations on choosing a ROC-SOLID SC

More information

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications An ISO 9001:2008 Registered Company System Operation Idle Timer Controller - ITC805 2013-2018 Freightliner MT45 Contact InterMotive for additional vehicle applications The ITC805 system shuts down idling

More information

Generator Start Control Module

Generator Start Control Module Generator Start Control Module Part# GSCM Rev C. Code Version: 5.13 ATKINSON ELECTRONICS, INC. 14 West Vine Street Murray, Utah 84107 Table of Contents Operations... 3 Specifications... 3 GSCM Wiring Diagram...

More information

ICON 2 1. FEATURES AND CHARACTEIRICS

ICON 2 1. FEATURES AND CHARACTEIRICS ICON 2 1. FEATURES AND CHARACTEIRICS High end Micro-controller(DSP) technology Wide range of auxiliary supply: 7V to 45Vdc. Low power Consumption : 200 ma @ 12 V DC. Alphanumeric 16X4 or 16X2 LCD display

More information

AUTOMATIC AND MANUAL TRANSMISSION MODELS* *MUST USE M SERIES REMOTE STARTER!

AUTOMATIC AND MANUAL TRANSMISSION MODELS* *MUST USE M SERIES REMOTE STARTER! REV.2011.7.22 80 SERIES Advanced Remote Starters & Vehicle Security Systems AUTOMATIC AND MANUAL TRANSMISSION MODELS* *MUST USE M SERIES REMOTE STARTER! WARING: NEVER USE AN AUTOMATIC TRANSMISSION STARTER

More information

TD320 Differential Temperature Controller For HVAC

TD320 Differential Temperature Controller For HVAC AUBER INSTRUMENTS Instruction Manual WWW.AUBERINS.COM TD320 Differential Controller F HVAC Version 1.2 (Oct, 2017) 1. Overview TD320 is a temperature controller f heating, ventilating, and air-conditioning

More information

OUTDOOR UNIT CONTROLLER (OUC)

OUTDOOR UNIT CONTROLLER (OUC) AUCKLAND temperzone Ltd 38 Tidal Road, Mangere, Auckland. Private Bag 93303, Otahuhu, N.Z. Phone 0-9-279 5250 Fax 0-9-275 5637 Email sales@temperzone.co.nz WELLINGTON Phone 0-4-569 3262 Fax 0-4-566 6249

More information

- Wiring Brochure Universal Reset Module 422e

- Wiring Brochure Universal Reset Module 422e - Wiring Brochure Universal Reset Module 422e W 422e 01/08 1 Information Brochure hoose controls to match application 2 Application Brochure Design your mechanical applications 3 Rough In Wiring Rough-in

More information

Signet Temperature Transmitter

Signet Temperature Transmitter Signet 80 Temperature English 80.090 80.090 Rev. G /0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

PARTS & SERVICE MANUAL

PARTS & SERVICE MANUAL PARTS & SERVICE MANUAL Impinger Low Profile Advantage Digital Series (Electric) International Models MODELS: Please note that the model numbering system changed March 2007. The chart below shows the old

More information

Start-Up, Operation and Service Instructions

Start-Up, Operation and Service Instructions Article I. Krueger Proportional LineaHeat W/ Discharge Temperature Start-Up, Operation and Service Instructions SAFETY NOTE Air-handling equipment will provide safe and reliable service when operated within

More information

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

SERVICE MANUAL (DOMESTIC & INTERNATIONAL) SERVICE MANUAL (DOMESTIC & INTERNATIONAL) DUAL TECHNOLOGY FINISHER MODEL 1960 & 1980 SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Telephone:

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

4.2 Component Identification

4.2 Component Identification Digital Control Panels Deep Sea Electronics 5220 4.1 General 4.2 Component Identification 4.3 The YML5220 Controller 4.4 Description of Controls 4.5 Navigation 4.5.1 General Navigation 4.5.2 The Event

More information

Ion Technologies SUMPRO Battery Back-Up

Ion Technologies SUMPRO Battery Back-Up Page 1 of 6 Operation LCD Displays 1 2 3 NORMAL BATTERY BACKUP BATTERY CHARGING The unit is operating off of AC Line power and is functioning normally. ( - B indicates that Bump Down Mode is enabled).

More information

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL 5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL > Section DSE Model 5220 Automatic Mains Failure & Instrumentation System Operators Manual TABLE OF CONTENTS

More information

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE 012945A0 040906 1 MAIN FEATURES Power supply 230V~ ±10% 50Hz Backlit alphanumeric LCD display Management of 5 output

More information

Induction Power Supplies

Induction Power Supplies Induction Power Supplies 7.5kW; 135 400kHz 480V version (Integral Heat Station) User s Guide Model 7.5-135/400-3-480 SMD Control Brds Rev. D 5/08 Table of Contents 1. Specifications and features...3 2.

More information

Invertek. Battery Management Control System DC-SW-140 & DC-SW-140C DC-SW-70 & DC-SW-70C USER MANUAL

Invertek. Battery Management Control System DC-SW-140 & DC-SW-140C DC-SW-70 & DC-SW-70C USER MANUAL 利佳興業股份有限公司 RICH ELECTRIC CO.,LTD. Invertek Battery Management Control System DC-SW-140 & DC-SW-140C DC-SW-70 & DC-SW-70C USER MANUAL Rich Electric Co. DC-SW Battery Management Control System User Manual

More information

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL 1. INTRODUCTION VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down 24V to 12V DC-DC Converter has a programmable 12.0 to 15.0V output in

More information

DKG-109 AUTOMATIC MAINS FAILURE UNIT

DKG-109 AUTOMATIC MAINS FAILURE UNIT Tel: +90-216-466 84 60 Fax: +90-216 364 65 65 datakom@datakom.com.tr http://www.datakom.com.tr DKG-109 AUTOMATIC MAINS FAILURE UNIT FEATURES Automatic mains failure Engine control Generator protection

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750 An ISO 9001:2008 Registered Company Idle Timer Controller - A-ITC520-A 2009-2018 Ford E Series 2008-2016 Ford F250 - F550 2017-2018 Ford F250 - F550 (*B-ITC520-A) 2016-2018 F650/F750 *Uses the Ford 24-Pin

More information

USER MANUAL DCA15. Auto Aır Conditioner Controller Unit. Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17

USER MANUAL DCA15. Auto Aır Conditioner Controller Unit. Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17 USER MANUAL DCA15 Auto Aır Conditioner Controller Unit Elektrosan Elektronik Müh. San. Ve Tic. Ltd. ENG. DCA15 V01 03/17 INDEX 1) GENERAL DESCRIPTION 2) BEFORE USING THE DEVİCE 3) SAFETY PRECAUTIONS 4)

More information

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 FEATURES... 4 3 SPECIFICATION... 4 4 DISPLAY SYMBOL AND OPERATION... 5 5 ALARM... 7 6 PARAMETERS TABLE (ONLY

More information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power. Double Oven Electric Range Technical Information MER6765BA* Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit. Refer

More information

INSTALLATION INSTRUCTIONS T-59 SPACE TEMPERATURE SENSOR WITH OVERRIDE & SETPOINT ADJUSTMENT

INSTALLATION INSTRUCTIONS T-59 SPACE TEMPERATURE SENSOR WITH OVERRIDE & SETPOINT ADJUSTMENT INSTALLATION INSTRUCTIONS T-59 SPACE TEMPERATURE SENSOR WITH OVERRIDE & SETPOINT ADJUSTMENT COMPONENT LIST The Model T-59 Space Temperature Sensor with Override & Setpoint Adjustment consists of the following

More information

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures A419 Issue Date February 10, 2003 A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures The A419 series controls are single-stage, electronic temperature

More information

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No

More information

OPTI-Solar SC MPPT Series

OPTI-Solar SC MPPT Series www.opt i -sola r. c o m OPTI-Solar SC MPPT Series SOLAR CHARGE CONTROLLER SC-50 / SC-80 / SC-80X / SC-160X MPPT Installation and Operation Manual CONTENTS Introduction... Feature... Specification... Dimension...VII

More information

Application Guide Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1. Carlyle Controller Part No.

Application Guide Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1. Carlyle Controller Part No. Application Guide 575-012 Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1 Carlyle Controller Part No. 2BSB000928 1 General Description The PCM is part of Paragon Compressor

More information