1 METAL SEPARATOR Mesep Extractor Manual (English) Mesep Extractor, Version
2 Table of Contents 1. General Instructions on using the manual 3 2. Area of Utilisation and Qualifications Intended use Improper use Owner/operator s duty of care 5 3. General Safety Information Explanation concerning utilised safety symbols Fundamental safety measures 6 4. Instructions references for the metal separator Assembly instructions Operating instructions Metal separator s interference protection 9 5. Technical Data Technical Description Ring detector and evaluation electronics Cyclone and separating unit Sensitivity of the ring detector Product Effects bothersome product properties Transportation Safety Information for transit and assembly Assembly Instructions Assembly Electric connections Commissioning Maintenance General maintenance Cleaning Anti-wear plate (optional) Regular inspections Faults and Causes of Errors Spare Parts Annex 28 2
3 1. General 1.1. Instructions on using the manual This manual is valid for the Mesep Extractor Manufacturer: Pulsotronic-Anlagentechnik GmbH Neue Schichtstr Niederdorf Tel.: (+49) / Fax: (+49) / Issue date of documentation: August 2007, Version 0701 This manual contains all the information that is of relevance for the operation. Before commencing with work for the first time using the metal detector, this User Manual should be read and understood by all the persons who are authorized to work on and with the metal separator. Special stress should be placed on the Safety Information. The User Manual is a component of the metal separator and must always be available for the reference of the authorized circle of people. Chapters of this manual should never be removed from the manual at any time. Replace a missing manual or missing pages, especially the Safety Information chapter immediately if lost. Note: Pulsotronic does not grant an implied guarantee for the customary quality and suitability for a specific utilisation purpose. This documentation contains copyright protected information. It may not be copied, reproduced, translated or collected on data carriers, in whole or in part, without obtaining prior permission of Pulsotronic. This documentation is not subject to the updating services of Pulsotronic. Modifications in this documentation as well as all rights are reserved. 3
4 2. Area of Utilisation and Qualifications 2.1. Intended use The Mesep Extractor is integrated in the vacuum feed line just in front of the material intake. Please ensure that the metal separator is not permitted to warm up more than 50 C. The Mesep Extractor eliminates the detected metal particles at various or varying flow speeds, without having to be adjusted for this purpose. Note: The Mesep Extractor removes metal contaminants out of pourable, dry material column, which are drawn through the conveyor system and into the by means of vacuum, via a flap. The Messep Extractor was developed to protect plastic injection moulding machines, extruders or peripherals against metal contamination of all kinds. A small quantity of the good material is also discharged during the separating process, although the reliable removal of metal is in the foreground and a slight loss of material is technically unavoidable. It is necessary to observe a few marginal and usage conditions in order that the device will function reliably. This manual will deal with these points. Thus, reading this manual is absolutely mandatory to ensure a trouble-free operation. The maximum response sensitivity to metals is subject to technical and physical limits (see chapter on Technical Data). The Mesep Extractor is not suitable for removing metal from materials that fall freely or inside conveyor lines that are pressurized. The Mesep Extractor can be used to minimize damages due to metal contamination. Regular inspections of the devices is absolutely mandatory as components are involved, which could malfunction due to external influences or wear, in spite of the latest technology Improper use The Mesep Extractor metal separator is not intended for any other type of use than those indicated in 2. Area of Utilisation and Qualifications; anything else is considered an improper use! Please note that the following is forbidden: Removal or modification of the safety devices Using the metal separator for an unapproved use Converting the metal separator without Pulsotronic s permission in order to use it for another purpose. Bear in mind that you may be considered the manufacturer of the metal separator after such a conversion, along with all the consequences that are involved! 4
5 2.3. Owner/operator s duty of care The Mesep Extractor Metal Separator has been designed and constructed according to harmonized standards. Thus, it complies with the latest technology and ensures the highest possible degree of safety. This safety can only be achieved in operational practice if all the measures for this have been undertaken. Planning these measures and controlling their implementation belongs to the owner/operator s duty of care. The owner/operator must especially safeguard the following in particular: that the metal separator is only used for the intended purpose, (see 2.1, Intended Use ); that the metal separator is only operated when it is in a perfectly functioning condition and that the safety equipment in particular is examined at regular intervals to ensure it is functioning properly that the Operating Manual is available at all times and is in good legible condition that only adequately qualified and authorized staff may operate, service and repair the metal separator that the personnel must be trained on all matters of occupational safety and environmental protection before starting to work with it for the first time and must be familiar with the Operating Manual and especially the Safety references contained therein that none of the safety and warning information that has been attached to the machine is removed and that it remains legible 5
6 3. General Safety Information 3.1. Explanation concerning utilised safety symbols The following safety symbols are used in the Operating Manual concerned here. These symbols are mainly intended to draw the reader s attention to the text appearing beside the safety reference. Danger! This symbol indicates that there are dangers for life and limb. Danger! This symbol indicates that there are dangers for life and limb due to electrical voltage Fundamental safety measures 6 Do not reach into the openings on the metal separator. Mechanical forces are created after switching on the pneumatically operated points, which could cause injuries. Always disconnect the device from the compressed air and voltage supply before performing any maintenance work. Please ensure that no one can re-connect the compressed air or voltage supply before the work is completed. Never put the metal separator into operation without the safety equipment required on the factory side. These include the safety grates over the moving parts in particular. Immediately discontinue the operation if the safety equipment is not functioning properly or is damaged. If technical malfunctions occur during operation due to wear or fatigue, rectify these immediately. Set out a sufficient number of regular maintenance intervals. Always observe the safety information which is located on the unit itself. It can help to avoid dangers. Do not remove this information under any circumstances. Do not put the metal separator into operation if you: have not been briefed completely by the owner/operator, or have not read this Operating Manual in full, or
7 have not completely understood this Operating Manual. Operating errors can result in serious personal or property damages. Danger! Avoid touching the electronic circuit board. Disconnect the unit from the supply voltage and the compressed air supply before connecting the electronics to other peripherals. You will avoid unintended electrical short circuits as a result of this. It is necessary to ensure that static charges dissipate before any possible work commences. 7
8 4. Instructions references for the metal separator Trouble-free and safe operation of the Mesep Extractor Metal Separator is only possible, if the following points are observed Assembly instructions Fastening must be performed in such a way that none of the screws or other fastening materials can become loose unintentionally. The device may not be dismantled for assembly. The assembly must be carried out as a complete unit. No welding current may be allowed to flow through the housing on the metal separator under any circumstances! This would permanently destroy the metal separator! IMPORTANT INFORMATION The devices are not 100% airtight due to production-related reasons. Therefore, a very slight loss of air can be expected (approx. 17mbar at 16m/sec. air velocity). Thus, the suction-type conveyor system should have sufficient capacity reserves to compensate for this loss, so that the conveying of material is not affected and sufficient material can be conveyed to the machines. The losing of compressed air cannot be heard acoustically (no hissing noises). The escaping air involved is minimal. All the devices are checked to ensure they are sufficiently leakproof before leaving the factory. An impairment in the system has occurred in some cases if several devices were assembled simultaneously. Thus, it is necessary to clarify this prior to the installation of more than five devices at one time, to prevent any difficulties. Connection Instructions Ensure the mains voltage is the proper one. Installation and connections may only be performed by trained staff. Observe the installation requirements for erecting and operating electrical plant (VDE 0100). Never carry out any work when the metal separator is switched on! Carry out all protective measures for persons and machinery in accordance with the circumstances and regulations. Take the capacities of the output contacts into consideration. The metal separator must be well grounded (avoid star-shaped earth circuits, shortest link to main earth) Operating instructions The metal separator should remain switched on at all times. That way, the electronic circuits have the longest service life. 8
9 4.3. Metal separator s interference protection The metal separator s power input is protected against parasitic induction by the factory. Even higher operational safety and additional protection against functional faults is achieved through the following measures: Use of line filters, if the mains voltage is affected by switching on other large consumers (compensation systems, welding devices, HF furnaces, electromagnetic valves, etc.) Protective circuitry for inductive loads (solenoids, gates, electromagnets) as a result of RC elements. High voltage peaks can result from shutting off inductive loads. These high voltage impulses are short-circuited by the RC elements. 9
10 5. Technical Data Item designation Mesep Extractor 38, 45, 50 (with 50 mm ring) Mesep Extractor 55, 60, 65, 70 (with 70 mm ring) Operating voltage Power consumption 230 V / 50 Hz or 115 V / 60 Hz < 40 Watt Admissible operating temperature 0 C - 50 C Admissible product temperature Max. 60 C (with compressed air cooling max. 100 C) Weight Adjustable sensitivity (Max.) About 32 kg Mesep Extractor Fe in centre of ring FE- St37 Mesep Extractor FE-St Fe in centre of ring Material throughput Type-dependent l/h, depending on complete conveyor system and conveyed material Sensitivity setting Operating pressure Parts touching media Relay contacts Using potentiometer 4-6 bar filtered, free of water and oil Paper-based laminate and stainless steel Metal detection (floating changeover contact 250V/5A) Paintwork - housing RAL 5005 Measurements 450 mm * 450 mm * 300 mm 10
11 6. Technical Description This chapter provides information on the configuration and way in which your metal separator operates. The Mesep Extractor Metal Separator consists of three main functional units: o Ring detector / Chapter 6.1. o Evaluation electronics / Chapter 6.1. o Cyclone and separating unit / Chapter Ring detector and evaluation electronics The toroid s metal detector operates using an analog evaluation principal, which is briefly explained below. A high frequency electromagnetic alternating field is produced in a ring sensor by means of an oscillator. If a metal piece or electrically conductible materials fall through the ring sensor, eddy currents are produced inside it. These remove the energy from the electromagnetic field. This energy loss causes dampening of the oscillator, which in turn reduces the signal amplitude. The size of the dampening is a measure for the size of the metal piece and has a direct relationship with the magnetic and electric properties of the metal particle: Large metal particles draw more energy from the field than small metal particles. Magnetic metals (e.g. steel) draw more energy from the field than non-magnetic metals (e.g. aluminium). This measuring principle is suitable for all types of metal and makes it possible to detect metal participles within product or in non-metallic packaging. The examined products are not affected or changed in any way by this kind of measuring. The threshold value, the size from which metal is detected, is set using a potentiometer. Once this value is exceeded, the device trips an electrical impulse. A flap is addressed with this impulse in metal separators by means of the evaluation electronics and the metal particle is then discharged into the flow of rejects Cyclone and separating unit The conveyor system sucks the material through the metal separator. There, it passes the metal sensor first, and then flows through a cyclone and subsequently leaves the device via a separating filter. If metal is detected, this separating filter opens, in order to discard the metal foreign matter. A slight quantity of the good material is also discharged in the process. Compressed air is blown into the cyclone through the ring at the same time; this removes 11
12 any such metal pieces that might have continued to remain behind the ring. This blowout effect also cleans the entire cyclone, the separating filter and the ring detector at the same time. The separating filter independently folds back into the original position and the conveying continues. The conveyed material enters the upper part of the cyclone tangentially. The flow speed forces the material into a spiral motion, which is directed in a downward direction. As a result of the combined effect with the blown in compressed air, the material spiral breaks down inside the cyclone and the drops out (approx one handful of material). And precisely this causes the independence of various flow speeds within the system. Automatic adapting to the material speed. The electronic metal detection within the sensor occurs with practically no time delay. On the other hand, there is a delay in the separating mechanism, which requires a certain time (even if it brief) to flip from position 1 to position 2. The result is that metal particles that are travelling quickly penetrate quite far into the cyclone after they are detected, before the separating filter has responded fully. A slow flow causes the exact opposite to occur. As everything is separated out of the cyclone, it makes no difference whether the material is right at the top of the cyclone or already inside the separating filter or somewhere in between; it will be separated regardless Sensitivity of the ring detector In the event that the ring detector reacts to the product effects (see Chapter Product Effects 6.4), it is necessary to reduce the sensitivity. The sensitivity is set on the ring detector using a potentiometer. The door on the housing is opened for this purpose. The ring detector is located at the top left. A potentiometer, which is secured by a retaining screw to prevent unintentional repositioning, is located there. Loosen the little slotted retaining screw. You can now change the sensitivity as follows: Turning to the left up to the potentiometer limit stop causes the sensitivity to be reduced. Turning to the right up to the potentiometer limit stop causes the sensitivity to be increased. Once you reach the limit stop, please do not try to use force to turn the potentiometer any further. The potentiometer will break off and will be permanently damaged, and the complete device will malfunction. 12
13 The potentiometer has a visible scale between 1 and 10. The set value should be recorded and controlled at regular intervals. That is the only way to determine whether or not someone has altered the setting. At delivery, the potentiometer is set to Level 8. NOTE: For detection accuracy, it is irrelevant, whether metal parts are covered by material or not. Non-magnetic metals affect the magnet field of the ring spool less intensely than magnetic ones. Thus, you should expect to use a reduced responsiveness for these metals. Sensitivity Iron Stainless steel Mesep Extractor 38, 45, 50 (with 50 mm ring) 0.6 mm 2.0 mm Mesep Extractor 55, 60, 65, 70 (with 70 mm ring) 1.0 mm 2.5 mm 6.4. Product Effects bothersome product properties This chapter explains: what is understood by the term product effect ; why the metal separator reacts to a product effect. This knowledge will help you to use the best possible setting for the metal separator in order to avoid any spurious releases. What is understood by the term product effect? The metal separator reacts to magnetism and electric conductivity. Because of this, electrically conductive substances, as is the case with metal, will affect the measuring field. This results in a test signal for the electronics, similar to what occurs when metal is reported. This is referred to as a negative influence on the magnetic field due to product effects. The result of the product effect is a metal report by the metal separator, although in reality, the product is metal-free. Please keep in mind, for example, how salt changes the conductivity of water. The electric resistance of distilled water is infinitely high, provided the water is pure distilled water. Distilled water does not contain any salts or minerals. Dissolved salt changes the electric resistance to such an extent that the solution is electrically conductive. Similarly, some plastics have conductive properties due to the admixing of materials. Raw materials are more or less electrically conductive. Components such as: Salt Sugar Minerals Moisture Carbons (plastic granulate died black) cause the materials to be more or less conductive. The magnetic field is continuous affected as a result. Although there are no metal particles in the examined material, the metal separator may still report metal. The results are unnecessary rejects. The product effect takes on a characteristic value for every material. The achievable sensitivity in practice is dependent on how well a potentially existing product effect can be compensated by the metal separator. The Mesep Extractor of this model has no product effect fade-out (compensation) possibilities. Frequently, however, reducing the sensitivity is all that is required to avoid 13
14 this bothersome effect. The achievable sensitivity however in metal detection systems with integrated product effect compensation is considerably higher. (Please ask our head office for product group M-Pulse or Digital+ Extractor). Suppressing product effects in the Mesep Extractor : A product effect can only be suppressed to a certain extent in the Mesep Extractor by reducing the responsiveness (see Chapter 6.3.). Note: The intensity of the product effect is proportional to the material throughput. As a result of this, reducing the material throughput with critical materials can also bring about a reduction in the bothersome effects. 14
15 7. Transportation 7.1. Safety Information for transit and assembly Danger! To avoid machine damages or life-threatening injuries during transit and the installation of the metal separator, please observe the following points absolutely: Transit and assembly work may only be carried out by qualified persons under observation of the safety instructions. Take the following weights into consideration when selecting suitable load-bearing equipment: Metal separator, depending on size and model, to 32 kg approx. Protruding, sharp edges can result in injuries due to cuts. Suspended loads can fall down resulting in mortal danger; never walk or stand underneath suspended loads! Parts that are loosely lying on top of each other can slip and fall down. Also read the chapter entitled "General Safety Information". 15
16 8. Assembly Instructions 8.1. Assembly The sturdy housing on the Mesep Extractor metal separator has four fastening brackets, which make wall assembly simple and fast. It is also conceivable that the unit could be used on a mobile rack. The setup location should be chosen in such a way that there is sufficient space for performing service work and so that it is possible to open the upper inspection flap and the housing door. The metal separator must be assembly horizontally to ensure it functions in a trouble-free manner. The other two axes must be arranged vertically. The unit will not operate in a horizontal position. In principle, the Mesep Extractor and the conveyor system must be switched off when the following system is connected. 1. Opening of the existing suction-type conveyor line 2. The material feed (incoming line) is connected to the left inlet socket on the Mesep Extractor by means of a plastic hose or metal tube. It is necessary to ensure this connection is leakproof, to avoid any loss of pressure. 16
17 Inlet socket 3. The material feed (incoming line) is connected to the left inlet socket on the Mesep Extractor by means of a plastic hose or metal tube. It is necessary to ensure this connection is leakproof, to avoid any loss of pressure. Discharge socket 17
18 4. The reject material chute on the Mesep Extractor situated on the bottom of the housing is connected to a collection container or a similar system by means of a hose or tube. 5. Mount the metal separator in such a way that it will suffer as little as possible shaking when in operation. Slight vibrations do not affect the separator. A metal alarm can be triggered though through a hard knock. 18
19 8.2. Electric connections 1 + Red 2 R Black 3 A White 4 - Blue 5 Solenoid valve 6 Flap Ring-Pulsor 7 Optional: solenoid valve Poti. A 8 Voltage and compressed air monitoring Poti. B S1 F L1 N Explanation of individual connections: 11/12: Optional compressed air monitoring (not standardly configured) An optional sensor can be connected here, which monitors the level of the compressed air. 16/17: Test key / Metal simulation Tests can also be triggered via an external floating contact, which is connected in parallel. 18/19: Output: 24 V DC/100 ma Permanent signal, for a signal lamp suitable as an equipment-on indicator 24/25/26: Only optionally equipped with changeover contact 250V/5A Break contact on 25 and 26 Make contact on 24 and 25 19
20 This is used for monitoring the voltage or the compressed air Changeover(N.O./N.C.) contacts 250 V/5 A 27/28: Closer contact 250V +/- 5A Shut when metal is ejected L1/N: Mains feed (230 VAC / 50 Hz or 115 VAC / 60 Hz) A: For setting the flap holding time in Eject metal position of 4 sec. Left limit stop sec. Right limit stop Exits 27/28 are also connected for the time the flap is open in Eject metal position. B: Setting the blow-off time of the cyclone with compressed air (preset at the factory) F1: Mains fuse: 230 VAC 0.25A time-lag fuse 115 VAC 0.5 time-lag fuse S1 Mains changeover switch for selling operating voltage 20
21 9. Commissioning Commissioning is very simple. However, check the following points once again: Inspect all the hose / pipe connections to make sure they are tight. Make sure that the threshold values for the supply voltage and compressed air have been observed. Observe the safety information and assembly instructions Close the door and the inspection hatch and ensure that no one can open the device when it is in operation. After a brief moment, you will be able to hear the flap switch into the good position Then re-start the material conveyor If the device reacts too frequently, refer back to the information in the Product Effects chapter and adapt the sensitivity to the material you are conveying. Re-setting of the sensitivity may be required after a material changeover, if the material properties have changed greatly or the device reacts too frequently. In most cases, too frequent switching is the result of conductive admixtures in the plastics. Adapting the sensitivity (responsiveness) may be required then. Place your confidence in the units and investigate the causes if the units sift frequently. With many applications, we have found that you may not get any metal report for days on end. Then, suddenly the device reacts several times in succession for an extended period of time. If this is the case, do not reduce the sensitivity immediately, but look for metals in the rejects and if you are successful, look for the causes. If there is metal in the plastic granulate due to broken off granulating milling knife pieces, then these will be distributed through a specific smaller volume of granulate. Maybe you just caught an octabine with material containing many of these little pieces and the metal detector reacts much more frequently because of the poor quality of this batch of material. Only reduce the sensitivity if you are really sure that the frequent switching occurrences are due to product effects. Granulate, which is highly contaminated with metal will result in the fact that the metal separators discharge a great deal of material (depending on the sensitivity level that is 21
22 set) and that the machines receive too little material. In that case, the strongly contaminated material should be cleaned through a separate metal collector first and then returned to production. Strongly contaminated material will cause the entire production sequence to malfunction from a certain degree onwards. There is a high degree of probability that continuous production will no longer be possible then. 22
23 10. Maintenance General maintenance The metal separator is a sensitive test device. The assembly and operation are described in this Operating Manual. Normally, the metal separator will work safely and reliably without requiring any further adjustments to be carried out after commissioning. It is however largely dependent on the conditions of use, and whether and when parts of the metal separator have to be replaced or if any setting adjustments are necessary. The paper-based laminate tube and the separating filter should be examined for wear at regular intervals in any case. During the processing of fibreglass reinforced materials or strong abrasive materials, this maintenance interval should be shortened. The exact maintenance intervals can be assessed better during the course of operation. Carry out daily or weekly checks at the beginning. The walls of the brown paper-based laminate tube can become especially thin due to strong abrasion. The paper-based laminate tube should be replaced before abrasion results in the formation of a hole. The highly sensitive ring spool (toroid) body protects against damages. If this instruction is not observed, the ring detector may be permanently damaged and will need to be completely replaced Cleaning The Mesep Extractor metal detector practically cleans itself as it blows compressed air into the cyclone every time metal is ejected. If a thorough cleaning should be necessary anyway, then proceed as follows: * Stop conveying material * Switch off metal detector and disconnect compressed air. Have all the safety instructions been observed? * Open housing roof on metal detector and open front flap. Clean cyclone with air. The metal detector is a sensitive test device. The assembly and operation are described in this Operating Manual. Normally, the metal separator will work safely and reliably without requiring any further adjustments after commissioning. It is however largely dependent on the conditions of use, and whether and when parts of the metal separator have to be replaced or if any setting adjustments are necessary. 23
24 The paper-based laminate tube should be examined for wear at regular intervals in any case. During the processing of fibreglass reinforced materials or strong abrasive materials, this maintenance interval should be shortened. The exact maintenance intervals can be assessed better during the course of operation. Weekly inspections should be carried out initially. The walls of the paper-based laminate tube and the cyclone become especially thin due to strong abrasion. Replace the paper-based laminate tube early enough before abrasion results in the formation of a hole. The highly sensitive ring spool (toroid) body protects against damages. Permanent damage to the ring detector is possible if this instruction is not observed; this will mean that it has to be replaced completely. Re-setting the sensitivity (responsiveness) may be necessary when changing from one bulk material to another. This might be necessary, for example, when switching from an undyed material to one that is dyed black, enriched with carbon black, if you experience an increase in the amount of material discharged because of metal contamination. (also see Chapter 6.3.) Anti-wear plate (optional) With fibreglass reinforced materials, we recommend using anti-wear plates. Fibreglass leads to a faster wear of the cyclone to a greater or lesser extent. When wear is well advanced, larger metal pieces can also break off and get into the production or the unit can loose its function. The plates are intended as sacrificial plates and clearly reduce the wear of the high quality cyclone, thereby helping to keep the maintenance costs as low as possible. This solution was designed so that the plates can be replaced quickly and easily as required with a few easy steps. The constant abrasion of the sacrificial plates in itself is not detectable with the most sensitive metal detection systems, as it distributes itself in the form of abrasion dust through tons of material. Thus, this is a type of wear that is always found throughout the entire conveyor system and is technology related. Replacing the plates must always occur before any larger pieces can break off. If no fibreglass reinforced or non-abrasive material is conveyed, the use of such plates is not absolutely mandatory. A retrofitting of such anti-wearing plates is possible at any time, even for the older devices. Please ask at our Head Office about such accessories Regular inspections Regular inspections on the devices are absolutely mandatory in spite of the high quality of the components involved, which could malfunction due to external influences or wear. An inspection of the separator must be carried out weekly and after maintenance stops or carrying out any repair work. In the event that malfunctions do occur, these must be rectified immediately, otherwise the machines or products, which are protected by the metal separator, will have to be taken out of operation. All the devices have a Test key on the left side of the housing. This test key can also be triggered by an external button connected in parallel. A metal signal is triggered after 24
25 pressing the button and the unit discharges material. The function of the unit can be tested in this way within a few seconds. We recommend testing the Mesep Extractor metal detector regularly with a predefined piece of test metal and recording the test results in a log book. At this time, we would also like to refer to our range of accessories, with a multitude of suitable standards test spheres. The test metal piece should consist of a sphere with the tiniest diameter that can be displayed. For test purposes, the spheres traverse through the metal separator together with the product and one observes, whether a metal signal follows. The test plan sets out when the metal separator is to be inspected, and by whom. For example: The shift electrician is to test the metal separator with the test metal piece one hour after the beginning of every shift. The test result is then recorded along with the date, time and signature in the log book. Example: Test sphere 1.5 mm FE detected, 24. August 2007, 08.30, signed J H Jones. In the event of a defect in the toroid or the electronics, repairs are only possible at the factory. The toroid is completed encapsulated with synthetic resin and is manufactured and tested in a complex process. The spool is then connected to the electronics. A series of function tests follow over several days. The units are only approved and shipped out once all the test results are successful. Repairs are therefore not possible on site. We would be pleased to provide you with a replacement unit following prior arrangements for the interim period. We have special tools at our factory with which we carry out adjustments and assembly work on the individual part in the Mesep Extractor metal detector. Only then can we guarantee the units will function perfectly upon leaving our factory. All the warranty entitlements become null and void if the user has personally tampered with the unit. If you notice any damages or faults on the units, let us carry out the inspection and repairs at the factory. Repairs frequently appear to be very simple at first glance, but fundamental things can be overlooked. Years of experience and technical patents are embodied in the units, which make them so high quality and reliable. This will save you consequential damages due to improperly carried out repairs or maintenance work. 25
26 11. Faults and Causes of Errors Frequent causes for malfunctions are incorrect settings or a lack of care with connections. Please isolate the cause of the fault using the following table. Frequently the malfunction is caused by a minor detail. If all attempts remain unsuccessful, jot down the unit number (can be found on the type plate, which is blued onto the frame) and get in touch with us. Observation Cause Remedy Irregular, very frequent metal reports. Device trips again and again after detecting metal Ejections whenever there are strong vibration/jarring Metal reports at same time as inductive or capacitive consumer switches. No metal report, although metal falling through ring detector. Check installation site: Loose screws? Sensitivity level too high on metal separator. Product effects? Severe metal contamination Excessive pressure on pneumatics causing strong vibration/jarring Strong impacts or vibrations/jarring Missing interference suppression on external components. Sensitivity setting too low Test object too small Check screws to ensure they are properly fastened Reduce sensitivity Possible black granulate, conductive product properties for material Check rejects again for metal contamination Test compressed air level bar Install pressure reducer Minimise cause of impacts See 4.2, Connection Information and 4.4, Metal separator s interference protection. Increase sensitivity Test another test object Malfunction in ring Malfunction - flap Dirty ring Large piece of metal got caught in ring Sticking or stiff flap Clean ring Malfunction compressed air No equipment-on indicator Compressed air failure or pressure too low No mains voltage Fine-wire fuse (0.5 A or 0.25 A time-lag) tripped Check compressed air 4-6 bar Check mains voltage Replace fuse What happens if the fault cannot be rectified? See Annex 13 re contacting Pulsotronic. 26
27 12. Spare Parts Solenoid valve for cleaning cyclone Flap Cellular rubber seal 1 m Funnel (cyclone) Connection neck f 38 mm Connection neck f 45 mm Connection neck f 50 mm Sheath tube for ring detector to Sheath tube for ring detector to Electronic circuit board 230/115 V
28 13. Annex In the event of technical questions, please speak to the Customer Service department or Technical Sales at Head Office. Contact: Tel.: (+49) / Switchboard Fax: (+49) / Switchboard Internet: Mail: info@pulsotronic-anlagentechnik.de 28
29 Ø10 (4x) Ø Ø Ø110 29
User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)
User Guide Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC) version 04/2013 Content General Information 3 Warning 3 Scope of Supply 3 Overview 3 General safety details 4 Intended use 4
More informationSwing Piston Compressors and Vacuum Pumps
Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation
More informationMETAL SEPARATOR QUICKTRON 03 R
METAL SEPARATOR Version 08/13 DETECTION OF ALL TYPES OF METALS FERROUS STAINLESS STEEL ALUMINUM COPPER BRASS... RELIABLE DETECTION OF FREE OR ENCAPSULATED CONTAMINANTS. FRAME MOUNTED METAL SEPARATOR FOR
More informationAppendix: Safety and application notes for... 15
Contents Safety... 2 Warnings... 2 Symbols used in this manual... 2 Operator s safety... 2 Avoid filter module damage... 2 DC-link resonance... 2 Description... 3 Description... 3 Ordering numbers, 380-415
More informationAssembly and Maintenance Manual Type ASNU
Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx
More informationOperating and Installation Instructions Swing Piston Compressors and Vacuum Pumps
Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps UNPK04DC Pressure UNPK04DCB Pressure UNPK04DC Vacuum UNPK04DCB Vacuum KNF Neuberger, Inc 2 Black Forest Rd Trenton, NJ
More informationITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa
5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,
More informationDUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS
4080 SE International Way. Suite B110, Milwaukie, OR 97222 (503) 654-0867 Fax: (503) 654-4671 email: ftech@filtertechnologyltd.com www.filtertechnologyltd.com DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE)
More informationOperating manual. Custom made gearboxes
Operating manual Custom made gearboxes DSS-Nr. 100389549 DSS-Rev. 001 Datum 16.01.2018 Contents Contents 1 General information 3 1.1 Using the operating manual 3 1.2 Warnings in this operating manual 4
More informationVBK 2596/12E/RSF. Thickness and Width Gauge for Strip and Profile. Operating- & Service Instructions. (with lateral guide rollers)
Thickness and Width Gauge for Strip and Profile (with lateral guide rollers) VBK 2596/12E/RSF Operating- & Service Instructions erstellt am 5.2.1998 freigegeben am Bemerkungen Rev.01 Seiten:16 Name: Rietdorf
More informationBowl feeder WV401-1 / Translation of operating and installation instructions
Bowl feeder WV401-1 / 402-1 Translation of operating and installation instructions Copyright by Afag GmbH This operation instruction applies to: Bowl feeder WV401-1 Bowl feeder WV402-1 Type 230 V / 50
More informationCRS-D Powder Coating Booth with Reverse Jet Cleaning System
Operating Instructions CRS-D Powder Coating Booth with Reverse Jet Cleaning System CRS-D (J) 27 1 1 1 2 2 2 4 4 4 3 3 3 CRS-D Booth with Reverse Jet Cleaning System 1 10 2 3 9 12 11 11 1 Exhaust air unit
More informationINSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z
INSTRUCTION MANUAL I/P Converter DSG BXXY3Z DSG BXXY4Z Revision 2.0 3.626 016136 en Page 1/15 Should you have any questions concerning the I/P converter, please contact the Service Department of the Product
More informationOperating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA
5.52.714.00.1.0 Edition 03.2004 GB Operating and Maintenance Manual for HADEF overhead crane as jointed crane TA Subject to changes. 1 HADEF Table of Contents 1 General Page 3 2 Product description Page
More informationOperating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN
Operating instructions Rotary actuators M135 M140 M150 M180 June 2012 / 118614 / EN General information General information Proof of amendment Copyright Subject to alterations Manufacturer Version Date
More informationAssembly and Maintenance Manual Type AS
Assembly and Maintenance Manual Type AS Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_AS.docx
More informationBasic Electrical Parameters of Reed Switch Products
REED SWITCH CHARACTERISTICS MEDER electronic Basic Electrical Parameters of Reed Switch Products Pull-In (PI) is described as that point where the contacts close. Using a magnet, it is usually measured
More informationBasic Electrical Parameters of Reed Switch Products
REED SWITCH CHARACTERISTICS Basic Electrical Parameters of Reed Switch Products MEDER electronic Pull-In (PI) is described as that point where the contacts close. Using a magnet, it is usually measured
More informationPURE SINE WAVE DC TO AC POWER INVERTER
PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read
More informationToothed belt axis ELGC-TB-KF. Operating instruction [ ]
Toothed belt axis ELGC-TB-KF en Operating instruction 8068220 2017-02 [8068222] Original instructions Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which can
More informationSheet Separator & Pneumatically sheet separator,
User Manual Sheet Separator & Pneumatically sheet separator, Series TxSx HSS Suitable for separating oiled steel sheets or steel sheets that stick together The descriptions and pictures in this manual,
More informationBraking Devices BR 230/ Assembly- and Commissioning Instructions
electronic Braking Devices BR 230/400-10...400 Assembly- and Commissioning Instructions Quality is our Drive. BR 230/400-10...400 1 as per 04/10 11600.10001 Table of Contents Page 1. Safety notes 3 2.
More informationSectional and Tilting Door Opener
Sectional and Tilting Door Opener Installation Instructions and User Guide 600 800 1000 S/N WARNING Please read the manual carefully before installation and use. The installation of your new door opener
More informationStarting up hydraulic systems
General / Installation A hydraulic system that operates economically, safely, and trouble-free requires careful planning, as well as proper installation and start-up. Conscientious maintenance has a considerable
More informationTRAIL-Control - Manufacturer -
Installation and Operating Instructions TRAIL-Control - Manufacturer - Release 03-2001 Müller Elektronik GmbH & Co. KG Franz-Kleine-Str. 18 33154 Salzkotten Datei: 302901-02_E(ME015488)_PDF.DOC Contents
More informationUser Manual Rittal PMC UPS 6kVA
User Manual Rittal PMC UPS 6kVA Germany Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Tel.: ++49-27 72-5 05-0 Fax: ++49-27 72-5 05-23 19 Internet: www.rittal.de 26 Contents 1. Introduction...
More informationOperating Instructions
Operating Instructions Ex UPS Combination of > 8265/5 GUBox control panel > 8316 battery box Contents 1 Contents 1 Contents 2 2 General Information 2 3 Safety Instructions 2 4 Conformity to standards 3
More informationPressure chlorine changeover unit C 7520
BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520
More informationOperating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:
Operating manual HDA eco Box 12/24V DC Automatic Dispenser Item No.: 110 500 900 Translation of the original operating manual Important! Copyright The operating manual is always to be read before commissioning
More informationSchmidt Mess- und Regeltechnik
Content 1. Preface 2 2. 3. 4. 5. 6. 7. 8. 9. Safety hints 2 Principle of operation 3 Installation 3 Electrical connection 4 Switch point adjustment 7 Maintenance 7 Fault finding hints 8 Specifications
More informationInstallation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator
Installation, Operating & Maintenance Instructions All-metal gate valve with compact or extended pneumatic actuator Series 48 DN 16 320 mm (I.D. ⅝" 12") This manual is valid for the following product ordering
More informationCompact System NRGS 11-2 NRGS Original Installation Instructions English
Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive
More informationInstallation and Operation Instructions. VAG ROTOP Portable Electric Drive
Installation and Operation Instructions VAG ROTOP Portable Electric Drive KAT-B 5551 Edition 1-01/2018 Content 1 General 3 1.1 Safety 3 1.2 Proper use 3 2 Transport and Storage 3 2.1 Transport 3 2.2 Storage
More informationUnit Protection System for Pumped-Storage Power Stations
Unit Protection System for Pumped-Storage Power Stations 1. Introduction In many power systems, pumped-storage power stations are used in addition to run-of-river power stations. These power stations serve
More informationGeneral Instructions and Inspection Instructions for Crane
General Instructions General Instructions and Inspection Instructions for Crane Distributed by Ergonomic Partners Sales@ErgonomicPartners.com www.ergonomicpartners.com Tel: 314-884-8884 EN R_(EN)/1 --
More informationSPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL
SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL MOTORTECH Tools & Test Equipment for Ignition Systems P/N 01.10.019 Rev. 01/2013 Copyright Copyright 2012 MOTORTECH GmbH. All rights reserved. Distribution
More informationWilo-Control SC-Fire Jockey
Pioneering for You Wilo-Control SC-Fire Jockey de en fr Einbau- und Betriebsanleitung Installation and operating instructions Notice de montage et de mise en service nl Inbouw- en bedieningsvoorschriften
More informationVIBRA MASCHINENFABRIK SCHULTHEIS
Page 1 of 7 Spare parts phone: 069 / 86 000 3-721 fax: 069 / 86 000 3-777 with Motor Vibrators or Electromagnetic Vibrators Operating Instructions Content Page 1 General technical information... 2 2 Installation...
More informationSafety Sensor CSS 180 Product Information
Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 CSS180CSS 180 PDF-M / EN 60947-5-3 EN 954-1 Control Category 4 IEC 61508, suitable for use in SIL 3 applications BG Type-Certification in
More informationSHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual
Electronic Motor Brake Type G Instructions and Setup Manual Table of Contents Table of Contents Electronic Motor Brake Type G... 1 1. INTRODUCTION... 2 2. DESCRIPTION AND APPLICATIONS... 2 3. SAFETY NOTES...
More informationLEVEL SWITCH WITH 1 FLOAT
RIL210 LEVEL SWITCH WITH 1 FLOAT LEVEL Immersion level controller with 1 or 2 control points It can be used for dirty liquids, water, petroleum, cutting oils, and tolerates the presence of metal and ferrous
More informationHST -LS Interlocking device (Translation of Original Manual)
Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image
More informationKEWTECH. KT56 digital multi function tester. Instruction manual
KEWTECH KT56 digital multi function tester Instruction manual Contents 1 Safety Notice 1 2 Features and Principles of Measurement 3 3 Introduction 6 4 Specifications 7 5 Instrument layout 9 6 Operating
More informationOperating Instructions
Dimensions UNS1000 Operating Instructions Level Switch Type UNS Dimensions UNS2000 1 Intended Applications... 2 2 Safety Instructions... 2 3 Standards... 3 4 Warranty/Guaranty... 3 5 Transport/Storage...
More informationApplication Note. First trip test. A circuit breaker spends most of its lifetime conducting current without any
Application Note First trip test A circuit breaker spends most of its lifetime conducting current without any operation. Once the protective relay detects a problem, the breaker that was idle for maybe
More informationTechnical Manual Electrical Power Supply System T4002
Technical Manual Electrical Power Supply System T400 MOZELT GmbH & Co. KG Please observe the following safety information and recommendations before start-up! Copyright: MOZELT GmbH & Co. KG, D-4769 Duisburg
More informationInstallation and Service Instructions (Translation of the Original Instructions) SV120. C _EN 11/2009 Rev.0
Installation and Service Instructions (Translation of the Original Instructions) SV20 Introduction Carefully read these Installation and Service Instructions prior to the installation and start of operation
More informationInstruction Manual. Harmonic Filter AHF 005/010. Drives Solutions
Harmonic Filter AHF 005/010 Instruction Manual Drives Solutions Contents Safety... 2 Warnings... 2 Symbols used in this manual... 2 Operator s safety... 2 Avoid filter module damage... 2 DC-link resonance...
More informationSafety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15
17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas
More informationTranslation of the Original operating instructions Lifting device Z 70 /...
Translation of the Original operating instructions Lifting device Z 70 /... Content 1. Lifting device / Correct use according to regulations 2. Basic principles 3. General information 4. Special remarks
More informationSUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2
SUBMERSIBLE WATER PUMP Model Nos. CSE400A Part No. 7231100 0917 iss 2 OPERATING & MAINTENANCE INSTRUCTIONS Thank you for purchasing this Clarke Submersible Pump. This highly efficient pump is designed
More informationBELT CONVEYOR CB/M5 Series
BELT CONVEYOR CB/M5 Series User and maintenance manual 1 DECLARATION OF CONFORMITY The company: Tel. +39-0444 450 620-451 520 Fax +39-0444 671 840 declares under its own responsibility that the machine
More informationCM3-E Operation Manual DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter
-E DOK-347E / Rev.:1.01 KH / October 1999 Portable 3 turbine check meter Contents 1 General Remarks... 1-1 1.1 About This Manual... 1-1 1.2 How to Use This Manual... 1-1 2 Approval... 2-1 2.1 Explosion
More informationInstallation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor
World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com
More informationSUBMERSIBLE WATER PUMPS
SUBMERSIBLE WATER PUMPS Model Nos. CS85S - CS85SA CS120S - CS120SA CS185S - CS185SA CS240S - CS240SA CS305S - CS305SA OPERATING & MAINTENANCE INSTRUCTIONS 1000 CONTENTS Warranty conditions... 3 Safety
More informationOil-free piston compressors KK and piston vacuum pumps KV
Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols
More informationEasySelect-Cup Manual Powder Gun
E Operating Instructions and Spare parts list EasySelect-Cup Manual Powder Gun EasySelect-Cup 27 28 EasySelect-Cup Table of Contents Safety rules EasySelect-Cup Manual Powder gun...........................................
More informationThe Discussion of this exercise covers the following points:
Exercise 2 Float Switch EXERCISE OBJECTIVE Learn the working principle of float switches and how to use the float switch, Model 46935. DISCUSSION OUTLINE The Discussion of this exercise covers the following
More informationSAFETY PRODUCTS. ASK-Series Safety Mat Product Manual
SAFETY PRODUCTS ASK-Series Safety Mat Product Manual 2TLC010047M0201_D ORIGINAL INSTRUCTIONS Read and understand this document Please read and understand this document before using the products. Please
More informationSECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E
SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE Comfort 800E/1000E WARNING Please read the manual carefully before installation and use. The installation of your new door opener
More informationFF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS
FF 20 INSTALLATION INSTRUCTIONS DIAPHRAGM PUMP FF 20 DCB-4 FF 20 DC-M Before operating the pump and the accessories, please read the Installation Instructions and safety precautions. Installation Instructions
More informationSpindle axis ELGC-BS-KF. Operating instructions [ ]
Spindle axis ELGC-BS-KF en Operating instructions 8067243 2017-01 [8067245] Original instructions Identification of hazards and instructions on how to prevent them: Danger Immediate dangers which can lead
More informationGL1200T Cut & Seal. (GL1200 Seal only)
GL INSTRUMENTS Technical Description & Operating Instructions Safe Seal Cut & Seal Welder for Filter Sacks GL1200T Cut & Seal (GL1200 Seal only) For industrial use only Important Safety & Operating Instructions
More informationBattery Power Inverters
Battery Power Inverters Renogy 500W 1000W 2000W Pure Sine Wave Inverter Manual 2775 E. Philadelphia St., Ontario, CA 91761 1-800-330-8678 1 Version 1.4 Important Safety Instructions Please save these instructions.
More informationInstallation manual wall-mounted distributor
EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2
More informationTC TC Operating instruction
TC 2060 - TC 3070 Operating instruction IMPORTANT SAFETY INSTRUCTIONS To guard against injury, basic safety precautions should be observed, including the following. 1) READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
More informationGL1200T Cut & Seal. (GL1200 Seal only)
GL INSTRUMENTS & Operating Instructions Safe Seal Cut & Seal Welder for Filter Sacks GL1200T Cut & Seal (GL1200 Seal only) For industrial use only Important Safety & Operating Instructions Please read
More informationExchange of rollers from the XTS-Mover
Service documentation for AT901-0050-0550 and AT9011-00x0-0550 Version: Date: 1.0 0.10.017 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1. Documentation issue
More informationTension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!
Tension Meter FT Series S C H M I D T c o n t r o l i n s t r u m e n t s Edition FT 03.E Model FT Instruction Manual Valid as of: 01.09.2011 Please keep the manual for future reference! Contents 1 Warranty
More informationH.S. MACHINERY RING COMPRESSORS
OPERATION & PARTS MANUAL Thank you for purchasing an H.S Machinery Limited Regenerative Blower. This product is manufactured under strict ISO-9001-2000 quality control guidelines to ensure your satisfaction.
More informationLinear unit, pneumatic KHM 40
Translation of original operating manual Linear unit, pneumatic KHM 40 Assembly and Operating Manual Superior Clamping and Gripping Imprint Imprint Copyright: This manual remains the copyrighted property
More informationInstallation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM
Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5
More informationOperating instructions Solenoid interlock TKM/TKF. 1. About this document. Content
1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies
Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain
More informationOperating Instructions
Operating Instructions COMBIPHON SEWERIN Wir sichern Lebensqualität. GB 103411 Measurable success by Sewerin equipment You settled on a precision instrument. A good choice! Our equipment stands out for
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More informationElectronic Ballast EVG 2000-T
Electronic Ballast EVG 2000-T Operating Manual Table of contents 1 Description 1.1 Advantages of this ballast... 3 1.2 Functional principle... 3 1.3 Energization... 4 1.4 Visualization... 5 1.5 Indications
More informationSWINGDOOR Power Drive 1401
T-1182 e 4.06 Operating Instructions for automatic swing doors SWINGDOOR Power Drive 1401 Contents 1 About these Instructions 4 2 Safety 5 2.1 General Safety and Accident Prevention Instructions 5 2.2
More informationInstallation and Operating Instructions Electric Vibrators HV/VFL Series
Installation and Operating Instructions Electric Vibrators HV/VFL Series Original Instruction Würges Vibrationstechnik GmbH Daimlerstraße 9 D-86356 Neusäß Telephone +49 821 463081 Telefax +49 821 463084
More informationModel HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006
B R A N D Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com
More informationOperating Instructions Pedestrian Turnstile Type MPT 33
Operating Instructions Pedestrian Turnstile Type MPT 33 Contents 1. Delivery...2 2. Safety...2 3 Description and operation...3 4. Foundation...4-5 5. Assembly and installation...6-9 6. Electrical connection...10-11
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies
Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...
More informationInstallation and Operating Instructions. Magnetic band conveyer
Installation and Operating Instructions Magnetic band conveyer GB Table of contents Page 1 Description of machine and functions... 5 2 Danger and safety instructions... 6 2.1 General instructions... 6
More informationPOWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL
POWER PINNER CD HAND WELDER 7300 OPERATOR S MANUAL Copyright: April 7, 2014 Gripnail Corporation Revised: January 25, 2018 An Employee Owned Company 97 Dexter Road East Providence, Rhode Island 02914-2045
More informationCommissioning & Maintenance Instructions. for. COBRA linear stepping motors
Commissioning & Maintenance Instructions for COBRA linear stepping motors ACP&D Limited. 86 Rose Hill Road, Ashton-under-Lyne, Lancashire, OL6 8NS. Tel : +44 (0)161 343 1884 Fax: +44 (0)161 343 7773 e-mail:
More informationTable of Contents. AMO series quantitative pressured centralized lubricating system 1. Illustration of AMO motor driven lubricating system 1
Table of Contents AMO series quantitative pressured centralized lubricating system 1 Illustration of AMO motor driven lubricating system 1 AMO motor driven thin oil lubricating pump MO type pressured thin
More informationOperating instructions
Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future
More informationOPERATOR MANUAL Combo Belt Conveyor
1 OPERATOR MANUAL Combo Belt Conveyor Document No. 11-01, Rev., 0816 2 WARNINGS THIS CONVEYOR IS DESIGNED FOR A SPECIFIC APPLICATION. CHECK FRAME AND METAL BELT FOR DAMAGE DURING SHIPMENT. READ THE MANUAL
More informationFL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.
FL 10 INSTALLATION INSTRUCTIONS DIAPHRAGM PUMP FL 10 DC-P FL 10 AC Before operating the pump, please read the Installation Instructions and safety precautions. Installation Instructions FL 10 Table of
More informationOperators manual Bumpa 8 metre 110v Bumpa 10 metre 110v
Operators manual Bumpa 8 metre 110v Bumpa 10 metre 110v SAFETY RULES Mk3 Bumpa Conveyor Danger Failure to obey the instructions and safety rules in this manual will result in death or serious injury. Do
More informationPTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2
1-4009-EN PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2 The PTEX extruder pumps are pneumatically actuated pumps designed to deliver lubricant under pressure to lubrication
More informationBELT CONVEYOR PNL/4 Series User and maintenance manual
BELT CONVEYOR PNL/4 Series User and maintenance manual 1 DECLARATION OF CONFORMITY CE In conformity with the 2006/42/CE Machine Directives, Enclosure II, section A The company: VIRGINIO NASTRI S.r.l. Tel.
More informationHST-BL-2830MS & HST-BL-2830MS-USA
HST-BL-2830MS & HST-BL-2830MS-USA Release date: 02/2017 High - System - Technik Im Martelacker 12 D-79588 Efringen-Kirchen Phone 0 76 28-91 11-0 Fax 0 76 28-91 11-90 E-Mail: info@hs-technik.com Web: www.hs-technik.com
More informationInstruction Manual. Sewage lifting station compli 300
Instruction Manual Sewage lifting station compli 300 Safety instructions Areas of application Electrical connection Installation Servicing Technical data Appendix JUNG PUMPEN GmbH Industriestr. 4-6 33803
More informationOPERATIONS MANUAL LEVER CHAIN HOIST
OPERATIONS MANUAL LEVER CHAIN HOIST IMPORTANT SAFETY INFORMATION Please read, understand and follow all safety information contained in these instructions prior to the use of this hoist. Retain these instructions
More informationPorte 150 Users Manual Swing Gate Opener 24V DC
Porte 150 Users Manual Swing Gate Opener 24V DC for residential use only Signal Light Push-button Control Box 14 Contents 1. Important Safety Information 2. Product Description and Application 2.1 Application
More informationPositive Displacement Pump
www.conairgroup.com U S E R G U I D E UGC028-1105 Positive Displacement Pump Models PD 3. 5, 7.5, 10, 15 and 25 Corporate Office: 724.584.5500 l Instant Access 24/7 (Parts and Service): 800.458.1960 l
More informationPRODUCT OPERATING MANUAL
PRODUCT OPERATING MANUAL PANBLAST TM CS37 SUCTION BLAST CABINET Manual Number: ZVP PC 0069 00 SECTION 1. GENERAL INFORMATION 2. ASSEMBLY & INSTALLATION INSTRUCTIONS 3. OPERATING INSTRUCTIONS 4. MAINTENANCE
More information