1 T835 Installation. 1.2 Rack Wiring. 1.1 Rack Mounting
|
|
- Melissa Oliver
- 5 years ago
- Views:
Transcription
1 M0-00 T Installation F. T Installation. Rack Mounting The T receiver is designed for use in a standard mm rack frame using a Tait T00 Series II guide. The guide is securely mounted to the rack frame with front and rear retaining screws, and the T is secured into the guide with two front panel mounting screws. Figure. shows a standard, double module guide which can also be fitted with an optional backplane PCB to locate and mate the rear D-range connector(s). For more information on available guide kits, refer to the T00 Ancillary Equipment Service Manual or your nearest Tait Dealer or Subsidiary.. Rack Wiring The D-range input and output connections are shown in Figure. and Figure.. Ensure that the cables are not subjected to any stresses due to tight bends or incorrect lengths. Make sure the RF coax cable to the N-type connector is free from sharp bends or twists. If access to the rear of the rack frame is restricted, the cable should be long enough to allow the chassis to be fully withdrawn from the guide. A rear mounted N-type connector is used for RF input on the T, while all DC, audio and control connections are via the rear mounted D-range connector, D-range (PL00). An additional rear D-range connector (T ) can be fitted when remote multichannel operation, or additional control or low frequency lines are required (refer to Figure.). Figure. T Double Guide Kit Can be configured as Audio by internal link resistors if required. Refer to Part I. Front Panel Mounting Holes Aperture For RF Figure. T D-Range Wiring - Rear View Slots For D-Range Optional Backplane PCB Mounts On Rear Of Guide Front Panel Mounting Hole Figure. T Chassis Open drain type; capable of sinking.ma via kω; V max. = V ds RX DISABLE CTCSS DISABLE CH_SLCT SERIAL COM AUX-OUT 0 AUX-OUT AUX-OUT 0 CH_SLCT 0 CH_SLCT CH_SLCT CH_SLCT CH_SLCT CH_SLCT CH_SLCT GND Figure. T D-Range Wiring - Rear View (standard T kit) Space For Optional (D-Range ) (D-Range ) Figure. above shows the standard pin allocations for the T auxiliary D-range kit. A T00-0 auxiliary D-range kit is also available for special applications requiring custom internal wiring. Copyright TEL 0/0/
2 F. T Installation M0-00. Power Supply If a power supply other than an appropriate Tait model is used, ensure that it is capable of providing enough current to drive the T00 system and is also free from excessive ripple or noise. The system should be protected by the use of appropriately rated fuses in the power supply. It is particularly important when the prime power source is a battery that fuses be employed in all supply lines.. Reverse Polarity Protection A shunt diode is fitted to all T receivers for protection against connection to a power supply of incorrect polarity. A fuse must be fitted in the power supply line for the diode to provide effective protection. 0/0/ Copyright TEL
3 M0-00 T/ Installation F. T/ Installation. Rack Mounting The T transmitter and T exciter are designed for use in a standard mm rack frame using a Tait T00 Series II guide. The guide is securely mounted to the rack frame with front and rear retaining screws, and the T/ is secured into the guide with two front panel mounting screws. Figure. shows a standard, double module guide which can also be fitted with an optional backplane PCB to locate and mate the rear D-range connector(s). For more information on available guide kits, refer to the T00 Ancillary Equipment Service Manual or your nearest Tait Dealer or Subsidiary. A rear mounted N-type connector is used for RF output on the T/, while all DC, audio and control connections are via the rear mounted D-range connector, D-range (PL00). An additional rear D-range connector (T ) can be fitted when remote multichannel operation, or additional control or low frequency lines are required (refer to Figure.). Front Panel Mounting Holes Figure. T Double Guide Kit Aperture For RF. Rack Wiring The D-range input and output connections are shown in Figure. and Figure.. Ensure that the cables are not subjected to any stresses due to tight bends or incorrect lengths. Make sure the RF coax cable to the N-type connector is free from sharp bends or twists. If access to the rear of the rack frame is restricted, the cable should be long enough to allow the chassis to be fully withdrawn from the guide. Sensitivity: -0dBm 0. to V DC Short together for +.V Line I/P normal operation High isolation keying option: Line I/P to 0V DC 0 To key PA, open Opto Key + Line I/P collector Line I/P Opto Key - Tx Enable External/auxiliary To key transmitter: Tx Key audio processing Audio high impedance <0.V = key Serial Com Can be configured as Gnd CTCSS Audio by internal link resistors link resistors if required. if required Power supply, -ve earth Refer to Part I. External CTCSS input: khz (00mV rms) Figure. T/ D-Range Wiring - Rear View Slots For D-Range Optional Backplane PCB Mounts On Rear Of Guide Front Panel Mounting Hole Figure. T/ Chassis Open drain type; capable of sinking.ma via kω; V max. = V ds TX RELAY DRV CTCSS DISABLE CH_SLCT SERIAL COM AUX-OUT 0 AUX-OUT AUX-OUT 0 CH_SLCT 0 CH_SLCT CH_SLCT CH_SLCT CH_SLCT CH_SLCT CH_SLCT GND Figure. T/ D-Range Wiring - Rear View (standard T kit) Space For Optional (D-Range ) (D-Range ) Figure. above shows the standard pin allocations for the T auxiliary D-range kit. A T00-0 auxiliary D-range kit is also available for special applications requiring custom internal wiring. Copyright TEL 0/0/
4 F. T/ Installation M0-00. Power Supply If a power supply other than an appropriate Tait model is used, ensure that it is capable of providing enough current to drive the T00 system and is also free from excessive ripple or noise. The system should be protected by the use of appropriately rated fuses in the power supply. It is particularly important when the prime power source is a battery that fuses be employed in all supply lines.. Reverse Polarity Protection A shunt diode is fitted to all T transmitters and T exciters for protection against connection to a power supply of incorrect polarity. A fuse must be fitted in the power supply line for the diode to provide effective protection. 0/0/ Copyright TEL
5 M0-00 T/ Installation F. T/ Installation Top Rail. Rack Mounting RF Output The T and T PAs are designed for use in a standard mm rack frame using Tait T00 Series II guide rails. The guide rails are securely mounted to the rack frame with front and rear retaining screws, and the PA is secured into the guide with two (T) or four (T) front panel mounting screws. Figure. shows the standard, double width guide designed for use with the T, while Figure. shows how the PA can be latched in the extended position. For more information on available guide kits, refer to the T00 Ancillary Equipment Service Manual or your nearest Tait Dealer or Subsidiary. The PA rear panel has three connectors: a BNC for RF input (from an adjacent T exciter), an N-type for RF output and a D-range for all DC, audio and control connections (refer to Figure. and Figure.). Caution: If you require continuous operation of the T, leave the rack module position immediately adjacent to the finned heatsink empty. There should be adequate airflow over the fins at all times. Extra airflow can be provided by fitting an auxiliary fan kit such as the T (refer to the T00 Ancillary Equipment Service Manual or your nearest Tait Dealer or Subsidiary for more details). RF Input D-range Bottom Rail Figure. PA In Latched Position You will need appropriate extension leads if you wish to carry out any adjustment procedures with the PA withdrawn from the rack in the latched position. Alternatively, disconnect and withdraw the PA and reconnect it behind the rack. Rack Mounting Holes Figure. T PA Guide Kit. Rack Wiring Front Panel Mounting Holes The D-range input and output connections are shown in Figure.. Ensure that the cables are not subjected to any stresses due to tight bends or incorrect lengths. Rack Mounting Holes Make sure the RF coax cables to the N-type and BNC connectors are free from sharp bends or twists. If access to the rear of the rack frame is restricted, the cables should be long enough to allow the chassis to be fully withdrawn from the guide. Figure. T Chassis BNC Connector D-Range Connector 0. to V DC Pull low to enable alarm outputs +.V Tx Key Gnd 0 Forward Power Alarm Reverse Power Alarm Forward Power Metering Reverse Power Metering Normally low, float on alarm conditions. 00mA sink capability. Will drive a coil meter Power supply, -ve earth BNC Connector D-Range Connector Figure. T Chassis Figure. T/ D-Range Wiring - Rear View Copyright TEL 0/0/
6 F. T/ Installation M0-00. Power Supply If a power supply other than an appropriate Tait model is used, ensure that it is capable of providing enough current to drive the T00 system and is also free from excessive ripple or noise. The system should be protected by the use of appropriately rated fuses in the power supply. It is particularly important when the prime power source is a battery that fuses be employed in all supply lines. Caution: Connect the power supply directly to the PA, and not via connector blocks. This will avoid overheating of connector blocks that are not of the correct current rating.. Reverse Polarity Protection A shunt diode is fitted to all T/ PAs for protection against connection to a power supply of incorrect polarity. A fuse must be fitted in the power supply line for the diode to provide effective protection. 0/0/ Copyright TEL
LAN Power Supply Module.
Revision 1.1 Sept. 2002 1 Contents Model 3000 / Access 4000 LAN Power Supply Module. Standard: P/N: 995050 Enhanced: P/N: 995050ENH INSTALLATION MANUAL Overview... 1 System Requirements and Reporting...
More informationFeatures. Description. Table of Contents
Features Very low profile Very high efficiency (typically 90%) Single and dual output versions Input voltages from 24V to 110VDC nominal voltages from 5V to 48VDC -40 C to +71 C operation without de-rating
More informationMclennan Servo Supplies Ltd. Bipolar Stepper Motor Translator User Handbook PM546
Mclennan Servo Supplies Ltd. Bipolar Stepper Motor Translator User Handbook PM546 Mclennan Servo Supplies Ltd. Telephone: 01276 26146 Yorktown Industrial Estate FAX: 01276 23452 22 Doman Road Camberley
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationSorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes
Sorensen XG 1700 Series 1700 W 1700 Watt, 1U Programmable DC Power Supplies 6 600 V Industry Leading Power Density Up to 1700 Watts in 1U Standard Digital Interfaces USB&RS232/485 LXI Ethernet and Isolated
More informationHILLSTONE DC LOAD BANK
OPERATING MANUAL for HILLSTONE DC LOAD BANK Type ref. HLD 240 480 100 Serial No. M36771 ISSUE 1 1 CONTENTS Introduction page 3 Safety Considerations page 3 Connecting procedure page 4 Operating instructions
More information3.5 Amp Bi-polar stepper motor drive MSE570 Evo 2
3.5 Amp Bi-polar stepper motor drive MSE57 Evo 2 Features Bi-polar drive with pre-set drive currents up to 3.5 Amps per phase Increased operating voltage up to 48 V ½ step drive option for improved damping
More informationEPS/ELA-Series User Manual EPS/ELA 250W
EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...
More informationCONTROLLER DIMENSIONS
Integral Circuits, LLC. LT50A WIRING AND INSTALLATION: (Preliminary) CONTROLLER DIMENSIONS V M M- V- SPEAKERS P4 P3 MU PORTS P2 P P9 P5 P0 P6 AUX. HORN/BELL SPARE and VLTG. SENSE AUX. FUSE/TEMP SENSE RADIO
More information& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL
72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com
More informationProfessional Wireless Products
Page 1 of 6 093115 Communications Power Supply and Battery Management Controller Page 2 of 6 1.0 Introduction The 093115 is a 13.8 volt 15amp transformer isolated switch mode down converter designed to
More informationVC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL
1. INTRODUCTION VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down 24V to 12V DC-DC Converter has a programmable 12.0 to 15.0V output in
More informationDycon D2430 EN54-4 Fire Alarm Power Supply Series
Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product
More informationMODEL ELC-12/40-CVM-D BATTERY CHARGER
NATIONAL RAILWAY SUPPLY MODEL ELC-12/40-CVM-D BATTERY CHARGER Installing, Operating and Service Instructions for the ELC-12/40-CVM-D Solid State Charger PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING
More informationMPS14 Rack Mount Power Supply
MPS14 Rack Mount Power Supply USER GUIDE Publication AP3898 Limited One Year Warranty This product has been manufactured in the UK by ALLEN & HEATH and is warranted to be free from defects in materials
More informationVC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL
1. INTRODUCTION VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL This MCU controlled Step Down DC-DC Converter has a digitally adjustable output in 0.2V increments. This
More informationSTATIC DAYLIGHT PAR 575 VF
STATIC LIGHT COMPANY LIMITED Unit 11, Meridian Business Park Fleming Road WALTHAM ABBEY EN9 3BZ www.staticlightcompany.com info@staticlightcompany.com TEL +44 (0) 1992 766 766 THIS INFORMATION IS DESIGNED
More informationXLR Energy Storage Module
Technical Note 19 XLR Energy Storage Module XLR Energy Storage Module Safety The XLR 48 V module contains stored energy of 54 watt-hours and can discharge up to 97 amps if short circuited. Only personnel
More informationMaintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C
C Mobile Communications 13 AMPERE POWER SUPPLY 19A704647P1-P3 CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER
More informationINTECH Micro 2300-RTD6
INTECH Micro 2300-RTD6 6 Channel RTD Input Station Overview. The Intech Micro 2300 Series is a system of modular I/O Remote Stations, that add an even lower cost option to Intech s already extensive intelligent
More informationPPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM
PPS20 COMMUNICATIONS POWER SUPPLY AND BATTERY MANAGEMENT SYSTEM 2 Table of Contents Introduction:... 3 1.0: Operation Principles:... 3 1.1: Stand alone supply... 3 1.2: Backed up supply:... 3 1.3: Battery
More informationDycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD
Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain
More informationMaxi and Mini DC-DC Converter Evaluation Board
BRICK FAMILY USER GUIDE Maxi and Mini DC-DC Converter Evaluation Board Features...1 Introduction...2 Set Up + OUT, OUT...3 + S, S...3 Secondary Control (SC)...3 Primary Control (PC)...4 Parallel (PR)...4
More informationMODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM
MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...
More informationPREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.
EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL GLT.MAN-138 CONTENTS Introduction to the Premier Power Pack PSU... 2 Changes to EN54-4 (The Fire Alarm Equipment Power Supply Standard)... 3 Indications... 4
More informationDUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL
72-7570 DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL Table of Contents Specification 1 Safety 3 EMC 4 Installation 5 Connections 5 Operation 6 Maintenance 8 Specification General specifications
More informationCD3000S-1PH Thyristor Unit Heater Break version
USER S MANUAL Rev. 01/2007 CD3000S-1PH Thyristor Unit Heater Break version from 15A to 110A CD Automation S.r.l. Via Picasso 34/36-20025 Legnano (MI) ITALY Tel +39 0331 577479 Fax +39 0331 579479 E-Mail:
More informationATOTH-G Series BLDC Motor Controller. User s Manual
ATOTH-G Series BLDC Motor Controller User s Manual Contents Chapter One Summary...1 Chapter Two Main Features and Specifications.2 2.1 Basic Functions...2 2.2 Features... 5 2.3 Specifications...6 Chapter
More informationObserve all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.
Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary
More information2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE
2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to
More information8710 EN. Potentiometric Displacement Sensors. Models 8710, 8711
Potentiometric Displacement Sensors Models 8710, 8711 Code: Delivery: Warranty: 8710 EN ex stock 24 months Model 8711 Model 8710 Application Displacement sensors models 8710 and 8711 with resistance tracks
More information1. DBS series. Applications Manual
Applications Manual 1. 1.1 Pin configuration 1.2 Do's and Don'ts for module 1.2.1 Isolation 1.2.2 Mounting method 1.2.3 External input capacitor 1.2.4 Stress onto the pins 1.2.5 Cleaning 1.2.6 Soldering
More informationElectronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved
DRM TM DRM-HP TM Electronic Dynamo Regulator INSTRUCTION MANUAL COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved INTRODUCTION The Clover Systems DRM is a state-of-the art all-electronic voltage and current
More informationStereo Power Amplifier
4-569-998-12(1) Stereo Power Amplifier Operating Instructions GB For customers in the United States: The warranty for this product is included in this manual (page 12). Owner s Record The model and serial
More informationAWZ 110. AWZ 13,8V/1A/7Ah/LM
AWZ 110 v.1.3 AWZ 13,8V/1A/7Ah/LM Linear buffer power supply unit Grade 2. EN* Edition: 9 from 02.11.2017 Supercedes the edition: 8 from 23.01.2017 GREY POWER plus Features: EN50131-6 compliance, 1 2 grades
More informationOutput Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.
FEATURES Industrial Standard 2" X 1" Package Wide 2:1 Input Voltage Range Fully Regulated Output Voltage High Efficiency up to 88% I/O Isolation 1500 VDC Operating Ambient Temp. Range -40 to 85 Overload
More informationSwitching DC Power Supply
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary
More informationTC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0
TC-500PD8 TC-500PD8 Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION Revision: 2.0 727,. Phillips Drive City of Industry. CA 91748. USA http:// www.xeal.com.tw TEL: 626-303-8885 FAX: 626-301-0588
More information150 WATT HEW SINGLE SERIES DC/DC CONVERTERS
Features Description The 4:1 Input Voltage 150 W single HEW Series of DC/DC converters provide precisely regulated dc outputs. The output voltage is fully isolated from the input, allowing the output to
More information32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide
32XR 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide RED ALARM LIGHT LEVEL CONTROLLER H-O-A SWITCHES HORN SILENCE INNER DOOR MOTOR STARTERS WITH INTERCHANGEABLE OVERLOAD MODULES
More informationMJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series
DC/DC 2W, Highest Power Density MINMAX MJWI2 Series MJWI2 SERIES DC/DC CONVERTER 2W, Highest Power Density FEATURES Smallest Encapsulated 2W! Package Size 1. x1. x.4 Ultra-wide 4:1 Input Range Very high
More informationA Caspian Technology Company all materials presented are trade mark and copyright protected by C.M.TECHNOLOGY Pty Ltd
PPS12 230v AC to 12 VDC POWER SUPPLY WITH BATTERY MANAGER OPTION 2 Table of Contents Introduction:... 3 1.0: Input Voltage:... 4 1.1: Mains Hold Up (missing mains cycles):... 4 1.2: Mains Input:... 4 1.3:
More informationKelly HPM High Power Full Bridge Permanent Magnet DC Motor Controller User s Manual
Kelly HPM High Power Full Bridge Permanent Magnet DC Motor Controller User s Manual HPM72601 HPM72801 HPM12401 HPM12601 HPM12801 HPM14301 HPM14501 HPM14701 Rev.3.4 Dec. 2016 Contents Chapter1 Introduction...
More informationPSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC
PSBSH 2012B v.1.2 PSBSH 13,8V/2A/7Ah/HERMETIC Buffer switch mode power supply unit, EN** Edition: 7 from 02.11.2017 Supercedes the edition: 6 from 08.06.2017 Features: DC 13,8V/2A uninterruptible power
More informationFilm-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.
Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema
More informationSOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series
H & C SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series OPERATION This power controller is designed to regulate a resistive load by switching the load on and off in
More information(typ.) (Range) ±18 330# 89 MPW MPW
DC/DC 30W, Single & Dual Output FEATURES 2 x 1.6 x 0.4 Metal Package Ultra-wide 4:1 Input Range Operating Temp. Range 40 C to 80 C Short Circuit Protection I/O-isolation 1500 VDC Input Filter meets EN
More informationXLM 62V Energy Storage Module
Technical Note 10406 XLM Energy Storage Module XLM 62V Energy Storage Module Introduction The XLM energy storage modules are self-contained energy storage devices comprised of twenty-three individual supercapacitor
More informationPSU EN54-4 Power Supplies
PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in
More informationMiniBMS V3 User Manual
MiniBMS V3 User Manual CleanPowerAuto LLC MiniBMS is a battery management system designed for LiFePo4 cells, used in Electric Vehicles. MiniBMS is designed to be reliable and cost effective solution; it
More informationBATTERY SAVER LOW RIPPLE HO
INSTRUCTION MANUAL BATTERY SAVER LOW RIPPLE HO LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS MODEL #: 091-195-12 INPUT: 120 Volt, 50/60 Hz, 4.5 Amps RMS OUTPUT: 13.2 Volts DC,
More informationDKG-114 MANUAL AND REMOTE START UNIT
DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional
More informationRU BMS Power Supply and Battery Management System Owners Guide
RU2-4012- BMS Power Supply and Battery Management System Owners Guide (These instructions are intended for use by a technician familiar with electronic products) RU2-4012- BMS is a continuous duty power
More informationMiniBMS User Manual. Distributed version
MiniBMS User Manual Distributed version MiniBMS is a battery management system designed for LiFePo4 cells, used in Electric Vehicles. MiniBMS is designed to be reliable and cost effective solution; it
More informationG213V STEP MOTOR DRIVE REV 7: March 25, 2011
Thank you for purchasing the G213V drive. The G213V is part of Geckodrive s new generation of CPLD-based microstep drives. It has short-circuit protection for the motor outputs, over-voltage and under-voltage
More informationUSER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: 16 V Series: 48 V Series: BMOD0110 P016 B01 BMOD0165 P048 B06
USER MANUAL Maxwell Technologies Ultracapacitor Energy Storage Modules Models: 16 V Series: 48 V Series: BMOD0500 P016 B01 BMOD0165 P048 B01 BMOD0500 P016 B02 BMOD0110 P048 B01 BMOD0250 P016 B01 BMOD0083
More information2O3D3-19A REVB MOUNTING
Practice Section 1672 Issue 6, September 2014 MOUNTING ETL LISTED CONFORMS TO UL STD 60950-1 CONTENTS Multiple Patents Pending CLEI Code SOM2300C, CPR 204577 PAGE 1 INTRODUCTION... 2 1.1 Reason for Reissue...
More informationVariable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A
Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A Copyright Elenco Electronics, Inc. REV-D DC POWER SUPPLY 1 2 4 5 CURRENT VOLTAGE 13 3 6 C.C. C.V. 7 FINE COARSE FINE COARSE
More informationPID-1500 THERMOELECTRIC & RESISTIVE HEATER TEMPERATURE CONTROLLER INSTRUCTION MANUAL
LASER DIODE DRIVERS TEMPERATURE CONTROLLERS Simply Advanced Control for Your Cutting Edge Design PID-1500 THERMOELECTRIC & RESISTIVE HEATER TEMPERATURE CONTROLLER INSTRUCTION MANUAL P O Box 865, Bozeman,
More informationAC CURRENT ANALOG CLAMP-ON TESTER MODEL MCL-350 INSTRUCTION MANUAL
AC CURRENT ANALOG CLAMP-ON TESTER MODEL MCL-350 INSTRUCTION MANUAL Thank you very much for selecting our digital AC clamp-on tester. This model is complex instrument and employ a very reliable mechanical/electronic
More informationTECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00
TECHNICAL MANUAL EN Inverter / Charger Combi Combi SW 12V 1600VA Réf : PF.16088 Combi SW 24V 3800VA Réf : PF.16089 SAFETY PRECAUTIONS TO PREVENT ANY RISK OF ELECTRIC SHOCK OR FIRE, READ THIS MANUAL CAREFULLY
More informationMODEL ELC-12/60-D BATTERY CHARGER
*32198* NATIONAL RAILWAY SUPPLY Installing, Operating and Service Instructions for the 12/60 Solid State Charger MODEL ELC-12/60-D BATTERY CHARGER PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS
More informationInstallation, Operation and Maintenance Manual. EVC Controller (from February 2007)
Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions
More informationMAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -
MAKING MODERN LIVING POSSIBLE Quick Setup VLT FCM 300 Series Factory setting Motors type B14 & B34 mounting Reset (pushbutton) Start Jog Speed reference Fig. 1 - Reset to be closed short time for resetting
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Instruction Manual Model 1672 Triple Output Power Supply Contents Section Description Page No. CONTENTS 1 1 TEST INSTRUMENT
More informationNavigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares
Instruction replacement procedure INS/ANAINST/025 EN Rev. A Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares Kit references: flowcell, tundish, flowmeter,
More informationTECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +
TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 + 8 CABIN DOORS DESCRIPTION OF SWITCHES The unit may be programmed using the DIL switches on the front of the unit. If any change is made to any
More informationINSTRUCTIONS FOR USE
ROGOWSKI CURRENT TRANSDUCERS INSTRUCTIONS FOR USE RCTi and RCTi-3ph POWER ELECTRONIC MEASUREMENTS Ltd. Gloucester House, Wellington Street, Long Eaton, Nottingham, NG10 4HT, U.K. Tel: +44 115 946 9657
More informationL5000 Plus. Installation & Setup Guide
L5000 Plus Page 1 of 16 JDE1945 IssB s1 May 2009 Contents Description Page Safety... 3 Installation Standards 4 Specification. 4 Installation Procedure Pump Box. 6 Auxiliary Pump Boxes... 7 Connecting
More informationREVISED ATM72 Auto Transfer Module
Capricorn Controls DA01ATM1-1 Data & Application Note Page 1 of 8 REVISED - - - ATM72 Auto Transfer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom
More informationSilver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise
Silver T E L E C O M V2.0 Aug 2008 Pb. Features IEEE802.3af compliant Small SIL package size - 56mm (L) x 4mm (H) Low output ripple and noise Input voltage range 36V to 57V Only one low cost external decoupling
More informationAstrosyn Guide to Building a UPS using Lawtronics Open PCB Chargers
Guide to Building a UPS using awtronics Open PCB Chargers awtronics Division, The Old Courthouse, New Rd Ave, Chatham, Kent, M4 6B, ngland Tel +44 (0) 1634 815175 Fax +44(0) 1634 826552 www.astrosyn.com
More informationElectronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved
DRM TM DRM-HP TM Electronic Dynamo Regulator INSTRUCTION MANUAL COPYRIGHT 2014 CLOVER SYSTEMS All Rights Reserved INTRODUCTION The Clover Systems DRM is a state-of-the art all-electronic voltage and current
More informationThe information in this chapter will enable you to: 90VAC to Low voltage fault below 85VAC
C H A P T E R ➅ Hardware Reference Chapter Objectives Environmental Specifications Drive Temperature Motor Temperature Humidity The information in this chapter will enable you to: Use this chapter as a
More informationTECHNICAL DATASHEET#TD1516AX 3 AMP SOLENOID DRIVER
TECHNICAL DATASHEET#TD1516AX 3 AMP SOLENOID DRIVER User Selectable V or ma Input Bipolar or Unipolar 0-3A Output Adjustable Dither and PWM Frequency PCB Board or Packaged in Metal Housing P/N: RSD-x-3A-y
More informationPioneer 321 MSR. 2/14 Antwerpsesteenweg Gent - Oostakker T +32 (0) F +32 (0)
GB Instruction manual 2/14 www.welda.be F +32 (0)9 355 92 01 0 1 INTRODUCTION... 4 2 FRONT PANEL... 4 3 REAR PANEL... 5 4 INSTALLATION... 6 4.1 UNIT ASSEMBLY... 6 4.2 CONNECTIONS TO THE ELECTRICAL MAINS
More informationK25000 & KD25000 Series
K25000 & KD25000 Series Fire Alarm Power Supplies Installation, Commissioning and Operating Manual Man-1128 Issue 14 January 2016 Man-1128_K25400_series_Power_Supply_Manual_14 Page 1 of 20 Section Page
More informationLS200 Series Instruction Manual
LS200 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage may lead to an electrical shock, damage to the unit
More informationInstruction Manual. Model Y5020. Current Shunt. P/N September 1979
Instruction Manual Model Y5020 Current Shunt P/N 516591 September 1979 INTRODUCTION The Model Y5020 is a precision, four-terminal, current shunt designed for use in calibrating ac/dc current sources in
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc
More informationAutoranging Industrial Multimeter
Owner's Manual Autoranging Industrial Multimeter Model No. 82005 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More informationPAF F280 SERIES Instruction Manual
PAF450 600F280ERIES PAF450 600F280 SERIES Instruction Manual Before using this product Be sure to take note of precautions and warnings indicated in this manual when using this product. Improper usage
More informationINSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B
INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES PBA20-12 PBA20-24 OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B68-0175-00 About Brands and Trademarks Our company and product names described
More informationInstruction Manual. P/N Suzuki GSXR1300 Hayabusa 6 Speed Plug & Play Adapter Harness
Instruction Manual P/N 30-3550 2002-2007 Suzuki GSXR1300 Hayabusa 6 Speed Plug & Play Adapter Harness OVERVIEW The 30-3550 AEM Infinity Adapter Kit was designed for the 2002 2007 Suzuki GSXR1300 Hayabusa.
More informationHE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS
HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide (These instructions are intended for use by a technician familiar with electronic products) Integrated Smart Charger Integrated Low Voltage
More informationSignet Pressure Transmitter
Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents
More informationJRVCS2 TROUBLESHOOTING
JRVCS2 TROUBLESHOOTING This guide is made to ease troubleshooting the in-command system. It will cover the wiring code and where those wires are connected to the Body Control Module (BCM) and Display Commander
More informationBasic Characteristics Data
Basic Characteristics Data Basic Characteristics Data Model 1F 15F 2F 3F Circuit method Switching frequency [khz] Active filter 6 Forward converter 13 Active filter 6 Forward converter 13 Active filter
More informationEPM72 Engine Protection Module
Capricorn Controls DA01EPM1-1 Data & Application Note Page 1 of 8 EPM2 Engine Protection Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products All
More informationMounting an EX 8200 series Switch on a Rack or Cabinet Without Using a Mechanical Lift
Mounting an EX 8200 series Switch on a Rack or Cabinet Without Using a Mechanical Lift If you cannot use a mechanical lift to install the switch (the preferred method), you can install it manually. CAUTION:
More informationSDM72 Start on Demand Modules
Capricorn Controls DA04SDM72-2 Revised Design Page 1 of 6 SDM72 Start on Demand Modules Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products Application
More informationUSERS MANUAL MCD REMOTE OPERATOR
USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3
More informationOUTPUT VOLTAGE 5V MAX.INPUT CURRENT 16.0A 12V 7.0A 12V 12V 24V 35.0A 28V 48V 12V 15V 24V 28V 23.0A 48V 12V 15V 24V 28V 48V 11.5A
210W to Single Output Full Brick DC/DC Converters STANDARD FULL BRICK PACKAGE POWER DENSITY UP TO 5.53W/CM 3 EFFICIENCIES FROM 86-91% ACTIVE LOAD SHARING WIDE INPUT VOLTAGE RANGE ACTIVE LOAD SHARING REMOTE
More informationInstalling and Removing Power Supplies
Power Supply Overview, page 2 Installing Power Supplies, page 3 Removing Power Supplies, page 8 Finding the Serial Number, page 9 1 Power Supply Overview Power Supply Overview You can install two types
More informationBellMega BM-510. Operation Manual Ver: 1.0 Rev: 1
BellMega BM-510 Operation Manual Ver: 1.0 Rev: 1 CONTENTS Page Description 1 Operation 2 Safety 2 Charging 3 Service / Calibration 3 Specifications 4 Description The BellMega is a continuity tester for
More informationtwin engine two battery bank split charge system
twin two battery bank split charge system P2331 12 volt. P2331 part number. 12331-0 24 volt. P2341 part number. 12341-0 contactor current rating continuous... 0 amp @ mv / contact / 0 A start... 0 amp
More informationInstallation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies
Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies D1541 D1542 D1543 D1545 D1543-X-8 D1545-X-8 D1545-4BNC D154X Series 1A 2A 3A 5A 3A fitted with 8-way output splitter
More informationDC Distribution Panel User Guide # S
DC Distribution Panel User Guide # S2-61256-100 68-11926-100 Standard Limited Hardware Warranty LIMITED WARRANTY. Equipment manufactured by CTI Products, Inc. is warranted to be free from defects in material
More informationNoran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified
0322-03D Sept 02, 2010 Noran Tel FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified FEATURES 2 isolated groups (busses) of 5 GMT fuses each (20Amps/GMT position). Polarity
More information