Compact acuum Ejector Series Body width mm, Weight9 g (Single unit with vacuum pressure switch and suction filter) Conventional 21.mm mm One-touch fitting ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Digital vacuum pressure switch With LED display Series ariations Series Nozzle diameter mm Release valve acuum pressure switch Suction filter 7 1 ø0. ø0.7 ø1.0 N.C. N.O. Latching N.C. 1 NN output and analog output 1 N output and analog output 2 NN outputs 2 N outputs Filtration 30 µm 13-9-1
Compact acuum Ejector Series Ejector unit How to Order 1 07 1U K1 L D31 C Nozzle nominal size 0 07 1U 3M Ejector exhaust Solenoid valve combination (Refer to Table (1).) Symbol K1 K2 J1 J2 Q1 Q2 ø0. ø0.7 ø1.0 Silencer for single unit Silencer for manifold N.C. N.O. N.C. N.O. Latching positive common Latching positive common ilot valve (Refer to Table (1).) Standard type (1 W for DC) Note) Y DC low wattage type (0. W) L LO G Release valve N.C. N.C. None None N.C. None Note) In the case of the manifold type or when single unit valves are aligned closely with each other, avoid energization lasting more than 3 days. oltage (Refer to Table (1).) 1 2 3 4 0 AC 200 AC 1 AC 220 AC 24 DC 12 DC Electrical entry L plug connector, With 0.3 m lead wire With light/surge voltage suppressor L plug connector, Without connector With light/surge voltage suppressor Grommet, With 0.3 m lead wire (Not available for latching and AC types.) acuum switch electrical entry Manual override Non-locking push type Latching: ush-lock type B Locking slotted type C CL CN Check valve None K With check valve Note) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used. Warning q Cannot be used for vacuum retention. w Use a release valve. (Without a release valve, the work piece may not be released.) Connector type Lead wire length: 0. m Connector type Lead wire length: 3 m Connector type Without connector acuum pressure switch suction filter F only 1 NN output and analog output, D31 suction filter 2 NN outputs, D32 suction filter 1 N output and analog output, D1 suction filter 2 N outputs, D2 suction filter Only the type manual override is available with a latching type supply valve. In such cases, the supply valve and release valve come with a lock. Table (1) Combination of solenoid valve, pilot valve and power supply voltage q w e r t y u i Solenoid valve combination symbol K1 K1 K2 J1 J1 J2 Q1 Q2 ilot valve symbol Y Y AC 0 Combinations (1) to (8) in the above table are the only possible options. 13-9-2 Applicable power supply voltage AC 200 AC 1 AC 220 DC 24 DC 12
How to Order Compact acuum Ejector Series Manifold Z1 08 B S B Nozzle nominal size ø0. ø0.7 ø1.0 Manifold Ordering Example Number of stations Note) 01 1 station 02 2 station...... 08 8 station Note) Number of stations varies according to nozzle nominal size during simultaneous operation. Maximum number of stations in simultaneous operation Maximum number of stations in simultaneous operation 8 Stations Stations 4 Stations Z8-BSB 1 pc. 3M-K1YL-D31C 4 pcs. (Stations 1 to 4) 13M-K1YL-D31C 4 pcs. (Stations to 8) The stations are sequentially numbered. When viewed from the side of the vacuum ports, the far left station is designated as station 1. Left acuum port ka MODE SET1 SET2 ka MODE SET1 SET2 ka MODE SET1 SET2 ka MODE SET1 SET2 3M-K1YL-D31C ka MODE SET1 SET2 ka MODE SET1 SET2 ka MODE SET1 SET2 1 2 3 4 7 8 ka MODE SET1 SET2 13M-K1YL-D31C Right ilot exhaust port location B Both sides Exhaust S Silencer (Both sides) Supply port location B Both sides Flow Characteristics/Exhaust Characteristics Exhaust Characteristics Maximum vacuum pressure (ka) Maximum vacuum pressure (ka) -0 Maximum vacuum pressure 20 1 Air consumption Maximum suction flow Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) 0 0.1 0.2 0.3 0.4 0. 0. 0 2 4 8 Supply pressure (Ma) Suction flow (l/min(anr)) 7 Exhaust Characteristics -0 Maximum vacuum pressure Air consumption Maximum suction flow 0 0.1 0.2 0.3 0.4 0. 0. Supply pressure (Ma) 30 20 Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) 1 Exhaust Characteristics Flow Characteristics Maximum vacuum pressure (ka) Maximum vacuum pressure (ka) -0 7 Flow Characteristics -0 0 1 Suction flow (l/min(anr)) 1 Flow Characteristics ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Maximum vacuum pressure (ka) -0 Maximum vacuum pressure Air consumption Maximum suction flow 0 0 40 30 20 Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) Maximum vacuum pressure (ka) -0 0 0.1 0.2 0.3 0.4 0. 0. Supply pressure (Ma) 0 1 20 2 Suction flow (l/min(anr)) 13-9-3
Series Specifications Ejector Model Nozzle nominal diameter mm ø Maximum suction flow l/min(anr) Air consumption l/min(anr) Maximum vacuum pressure 0. 14 7 0.7 23 80 ka 1 1.0 22 4 Supply pressure range 0.3 Ma to 0. Ma Supply pressure Operating temperature range 0.3 Ma 0.43 Ma to 0 C Weight Single unit Note 1) 9 Switch and suction filter End plate assembly for manifold g 9 g 122 g Note 1) Including a 0.3 m connector for the supply and release valves. Including a 0.3 m connector for the supply and release valves and a 0. m connector for the switch. Calculation of weight for the manifold type (Single unit weight) x (Number of stations) + (Weight of end plate assembly for manifold) Example) Switch + 8 stations with suction filter 9 g x 8 + 122 g = 994 g Supply alve and Release alve Type (Refer to How to Order for solenoid Model valves on page 13-9-.) Fluid Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Lubrication Manual override Rated coil voltage ower consumption (current value) Electrical entry DC 0 AC 1 AC 200 AC 220 AC Standard type Q1- Normally closed type Low wattage type (0. W) Q1Y- Air, Inert gas 0. Ma 0.3 Ma to 0 C Not required Latching type Q1L- Normally open type 1-Q120- Non-locking push type / Lock type (tool type) ush-lock type Non-locking push type / Lock type (tool type) 12, 24 DC, 0, 1, 200, 220 AC 12, 24 DC 1 W 0. W 1 W 0. A ( ma) 0. A ( ma) 1.0 A ( ma) 1.1 A ( ma) 0. A ( ma) 0. A (.9 ma) 1.2 A ( ma) 1.3 A (.9 ma) Grommet L plug connector Grommet L plug connector With light/surge L plug connector With light/surge (With light/surge voltage suppressor) voltage suppressor ( voltage suppressor) acuum ressure Switch Model Refer to How to Order for vacuum pressure switches on page 13-9-. ( ) Rated pressure range Set pressure range Withstand pressure Fluid ower supply voltage Current consumption Ambient temperature range Ambient humidity range Withstand voltage Insulation resistance Switch output Maximum load current Maximum applied voltage Residual voltage Response time Hysteresis Display Display accuracy Output indicator light Analog output Note) Output voltage Linearity 1S-D31--AS 1S-D1--AS 1S-D32--AS 1S-D2--AS 0 to 0 ka 0 to 99 ka 0.2 Ma Air/Non-corrosive metal/non-combustible gas 12 to 24 DC ±% 3 ma or less [with power supply voltage of 24 DC and switch output ON (with no load)] to 0 C (with no freezing or condensation) 3 to 8 %RH in operation and saving (with no condensation) 00 AC for 1 min 0 MΩ or more (between live parts and pressure port at 00 DC) 1 NN output and analog output 1 N output and analog output 2 NN outputs 2 N outputs 80 ma (per output) 30 (for NN output) NN output: or less (at 80 ma inrush), N output: 1.2 or less (at 80 ma discharge) 2 ms or less 0 to 1% F.S. or less (adjustable) 2% F.S. or less (fixed) 0 to 1% F.S. or less (adjustable) 2% F.S. or less (fixed) 2-digit red LED ±3 %F.S. ±2 digits Lights up when output is ON (red LED). Lights up when output is ON (red for OUT1 and green for OUT2) (Only applicable to D31 and D.1) 1 to ±2.% F.S. or less ±0. F.S. or less 13-9-4
Compact acuum Ejector Series Construction Single unit Manifold t e r y o w q Component arts No. Description Material No. q w e r oppet valve assembly Nozzle Diffuser Release flow adjustment needle Aluminum Aluminum Aluminum t y u i o Solenoid valve Y L ilot valve Standard type (1W) DC low wattage type (0. W) Not available for AC type Latching positive common Actuation 1 Normally closed 1 Q1 2 0 u i Rated coil voltage 1 2 3 4 Q1 1 0 L How to Order L 0 AC 200 AC 1 AC 220 AC 24 DC 12 DC Replacement arts Description Material art no. Solenoid valve Filter element Sound absorbing material 1 (single unit) acuum pressure switch Sound absorbing material 2 (manifold) F F F Refer to How to Order below XT34--001-AS XT34--004 Refer to How to Order below XT34--003 Check valve K None With check valve Note) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used. Warning q Cannot be used for vacuum retention. w Use a release valve. (Without a release valve, the workpiece may not be released.) acuum pressure switch 1S D 31 C AS ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Actuation 2 Normally open Rated coil voltage 24 DC 12 DC ilot valve Standard type (1W) Electrical entry L plug connector L With 0.3 m lead wire L plug connector LO Without connector Grommet G With 0.3 m lead wire (Not available for latching and AC types.) Note) Mounting screws are attached. 31 32 1 2 Manual override Non-locking push type Latching: ush-lock type B Locking: Slotted type Note) Only the "" type is available with a latching type. Switch specifications 1 NN output and analog output 2 NN outputs 1 N output and analog output 2 N outputs Electrical entry Connector type C Lead wire length: 0. m Connector type CL Lead wire length: 3 m CN Without connector Note) Mounting screws are attached. 13-9-
Series Dimensions Type K1 11U-K1- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) 3 30. (74.9) Lead wire length (approx. 0.3 m) (49.) (Grommet type) (3.1) 13.1 32 17. 23 33 2 2.8 4-ø3. Mounting Bracket A (standard) Release valve 7 Release flow adjusting screw acuum pressure switch 7.3.9 71.9 ka MODE SET HYS acuum port ( port) (M x ) Circuit 11U-K1- D F DK Note 1) The above dimensions are for 11U-K1 -DC. In the case of 11U-K1-F, the overall length is 87.2. Dimensions marked with are those after bracket A is mounted. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the Type J1 11U-J1- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) Circuit (3.1) (AC type) 3. (3.1) 11U-J1- D F Bracket A (standard) 7 acuum pressure switch.9 71.9 Note 1) The above dimensions are for 11U-J1 L-DC. In the case of 11U-J1-F, the overall length is 87.2. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the ka MODE SET HYS acuum port ( port) (M x ) 13-9-
Compact acuum Ejector Series Dimensions Type K2 11U-K2- Release flow adjusting screw ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) Circuit 11U-K2- (8.4) F D DK 2.8 Bracket A (standard) 87.2 Release valve 7.3 acuum port ( port) (M x ) Note 1) The above dimensions are for 11U-K2 L-F. In the case of 11U-K2-D, the overall length is 7. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Type J2 11U-J2- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) (8.4) Bracket A (standard) 87.2 acuum port ( port) (M x ) Note 1) The above dimensions are for 11U-J2 L-F. In the case of 11U-J2-D, the overall length is 7. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the Circuit 11U-J2- F D 13-9-7
A A Series Dimensions Type Q1 11U-Q1- Release flow adjusting screw ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) (3.1) 3. B 0 Bracket A (standard) Release acuum pressure switch valve 2.8 7 7.3.9 71.9 ka MODE SET HYS acuum port ( port) (M x ) Circuit 11U-Q1- D F DK Note 1) The above dimensions are for 11U-G1 L-DC. In the case of 11U-Q1-F, the overall length is 87.2. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the Type Q2 11U-Q2- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) (3.1) 3. 0 B Bracket A (standard) 7 acuum pressure switch.9 71.9 ka MOD E S E T HYS acuum port ( port) (M x ) Circuit 11U-Q2- D F Note 1) The above dimensions are for 11U-G2 L-DC. In the case of 11U-G2-F, the overall length is 87.2. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the 13-9-8
Compact acuum Ejector Series Dimensions Manifold type Z1-BSB 13M-- Supply port 2-ø3. ( Note 1) ) L2 (3.) (0.1) L1. 13 (itch) = 8 ( Note 1) ) 3 Attached washer 3. 2-R1.7 ilot exhaust port ( port) (One-touch fitting for applicable tubing diameter of ø4, piping not required) Common air supply port ( port) (One-touch fitting for applicable tubing diameter of ø8) 2.8 7 Release valve Release flow adjusting screw acuum pressure switch Attached washer (72.4).2 ka MO DE SET HYS ka MO DE SET HYS ka MO DE SET HYS ka MO DE SET HYS ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Dimensions n L1 L2 1 2 2 2 3 2 3 4 2 4 72 9 8. 82 7 92 28.8 7 8 2 81 n: Number of stations (mm) 8 9 112 7 8. 9 21 acuum port ( port) (M x ) Note 1) The above dimensions are for Z1-BSB. 13M-K L-DC. In the case of 13M--F, the overall length is 87.2. Dimensions marked with " " are those after the attached square bracket is mounted. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of ports are determined assuming the use of the Series KJ onetouch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalogue to confirm the sizes of the fittings to be used. Circuit 13M-K1-D 13M-K2-DK 13M-J1-F 13M-Q1-FK 13-9-9
Series Manifold Exploded iew 3 4 b 4 b view 2 a a Component arts No. q w e r t y Description Hexagon socket head cap screw End block R End block L Ejector assembly Ejector body gasket for manifold Exhaust block gasket art no. Refer to How to Order. 1R-1-BSB-AS 1L-1-BSB-AS 13M-- Note) -3-00 -3-009 Note) Refer to page 13-9- for detailed description of How to Order. 1 How to Order Hexagon Socket Head Cap Screw XT34 4 0 0 Number of stations 0 1 station 0 2 station 12 8 station Working rocedure Disassembly Loosen and remove the hexagon socket head cap bolts q. Assembly 1. Install the ejector body gasket for manifold t into the gasket groove of each ejector assembly r. Install the exhaust block gasket y around the projected part. 2. Install the exhaust block gasket y around the projected part of the end block R w. 3. Install the ejector body gasket for manifold t into the gasket groove of the end block L e. 4. Align the ejector assemblies r, end block (R) w, and end block (L) e using positioning pins (at the two a positions) and fasten with a hexagon socket head cap bolts q (2 pcs.) (with a tightening torque of 0. Nm±0.0 Nm). 13-9-