Series ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc.

Similar documents
Space Saving Vacuum Ejector/Vacuum Pump System

Compact Vacuum Ejector

Space Saving Vacuum Ejector / Vacuum Pump System

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

Vacuum Equipment. Application. Series

Ejector Valve Unit Series ZYY/ZYX

Vacuum Unit Vacuum Ejector Vacuum Pump System RoHS Energy saving ejector Air consumption % reduction More efficient eject

Energy saving ejector

Vacuum Ejector with Solid State Timer

Vacuum Ejector. Series ZM

Large Size Vacuum Module:

Nozzle diameter: ø0.5, ø0.7, ø1.0, ø1.2. Features

Terminal Block Box (Spring Type) SY3000/5000/7000 Series

Energysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in)

Compact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms

Vacuum Ejector. Series ZM Applications

Large Size Vacuum Module: Ejector System/Vacuum Pump System. Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0

3 Port Solenoid Valve

Compact Vacuum Unit. 46 g Single unit weight. New RoHS. 17% reduced 21% Ejector/Vacuum Pump System. 10 mm mm mm.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Vacuum Ejector. Adaptable for manifold application

How to Order. 0.5 mmø 0.7 mmø mmø mmø mmø mmø mmø. Maximum vacuum pressure S L. 88 kpa 48 kpa. SUP.

Vacuum / Release Unit

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K. Note 6)

5 Port Solenoid Valve

5 Port Solenoid Valve

Series SYJ300/500/700

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

MULTISTAGE MICRO EJECTORS

Large Size Vacuum Module:

Specifications. Fluid Ambient and fluid temperature ( C)

Vacuum Module. Series ZX. Ejector System/Vacuum Pump System

Rubber seal 3 Port Pilot Solenoid Valve. Specifications. Fluid Operating pressure range MPa. Internal pilot

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted

5 Port Solenoid Valve

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

ISO Standard Solenoid Valve. Series VQ7-6/7-8. (Size 1) (Size 2) Conforms to ISO Standard 5599/I

Series VQ Port Solenoid Valve

3 Port Solenoid Valve

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Large Size Vacuum Module:

Series ZM Applications

Pilot Operated 2 Port Solenoid Valve for Dry Air

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

2 position single 2 position double. 3 position Ambient and fluid temperature ( C) Note 1) 3 position Max. operating

Series VQZ1000/2000/3000 Single Unit

Vacuum pump system type

3 Port Solenoid Valve

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

5 Port Solenoid Valve

5 Port Solenoid Valve: Base Mounted Metal Seal/Rubber Seal. High speed & Long life. (Metal seal, with light and surge suppressor) 100 million cycles

How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K

Air Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Vacuum Release Valve with Restrictor

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Blanking. External Vacuum spec. (V) Standard pilot spec. (R) Vacuum spec. (V) Standard

2.26 S OLENOID VALVES S ERIES VQ1000

Series ZM Applications

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

Example. U side. Stations SY5000

Pilot Operated 2 Port Solenoid Valve for Dry Air

How to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

VQ1000. How to Order Manifold. Kit type

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Series VP3145/3165/3185

Series VP3145/3165/3185

4/5 Port Solenoid Valve

3 Port Air Operated Valve

External vacuum controller

Series ZM Applications

4/5 Port Solenoid Valve

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

2-Color Display High-Precision Digital Pressure Switch

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Power Consumption. 4/5 Port Solenoid Valve. Series SYJ3000/5000/7000. With Power Saving Circuit

I N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications

3 Port Solenoid Valve

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Vacuum ejector and vacuum unit model series variations

3 Port Solenoid Valve

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

4 Port Solenoid Valve

5 Port Solenoid Valve

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Related vacuum products

3 Port Solenoid Valve Direct Operated Poppet Type

Transcription:

Compact acuum Ejector Series Body width mm, Weight9 g (Single unit with vacuum pressure switch and suction filter) Conventional 21.mm mm One-touch fitting ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Digital vacuum pressure switch With LED display Series ariations Series Nozzle diameter mm Release valve acuum pressure switch Suction filter 7 1 ø0. ø0.7 ø1.0 N.C. N.O. Latching N.C. 1 NN output and analog output 1 N output and analog output 2 NN outputs 2 N outputs Filtration 30 µm 13-9-1

Compact acuum Ejector Series Ejector unit How to Order 1 07 1U K1 L D31 C Nozzle nominal size 0 07 1U 3M Ejector exhaust Solenoid valve combination (Refer to Table (1).) Symbol K1 K2 J1 J2 Q1 Q2 ø0. ø0.7 ø1.0 Silencer for single unit Silencer for manifold N.C. N.O. N.C. N.O. Latching positive common Latching positive common ilot valve (Refer to Table (1).) Standard type (1 W for DC) Note) Y DC low wattage type (0. W) L LO G Release valve N.C. N.C. None None N.C. None Note) In the case of the manifold type or when single unit valves are aligned closely with each other, avoid energization lasting more than 3 days. oltage (Refer to Table (1).) 1 2 3 4 0 AC 200 AC 1 AC 220 AC 24 DC 12 DC Electrical entry L plug connector, With 0.3 m lead wire With light/surge voltage suppressor L plug connector, Without connector With light/surge voltage suppressor Grommet, With 0.3 m lead wire (Not available for latching and AC types.) acuum switch electrical entry Manual override Non-locking push type Latching: ush-lock type B Locking slotted type C CL CN Check valve None K With check valve Note) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used. Warning q Cannot be used for vacuum retention. w Use a release valve. (Without a release valve, the work piece may not be released.) Connector type Lead wire length: 0. m Connector type Lead wire length: 3 m Connector type Without connector acuum pressure switch suction filter F only 1 NN output and analog output, D31 suction filter 2 NN outputs, D32 suction filter 1 N output and analog output, D1 suction filter 2 N outputs, D2 suction filter Only the type manual override is available with a latching type supply valve. In such cases, the supply valve and release valve come with a lock. Table (1) Combination of solenoid valve, pilot valve and power supply voltage q w e r t y u i Solenoid valve combination symbol K1 K1 K2 J1 J1 J2 Q1 Q2 ilot valve symbol Y Y AC 0 Combinations (1) to (8) in the above table are the only possible options. 13-9-2 Applicable power supply voltage AC 200 AC 1 AC 220 DC 24 DC 12

How to Order Compact acuum Ejector Series Manifold Z1 08 B S B Nozzle nominal size ø0. ø0.7 ø1.0 Manifold Ordering Example Number of stations Note) 01 1 station 02 2 station...... 08 8 station Note) Number of stations varies according to nozzle nominal size during simultaneous operation. Maximum number of stations in simultaneous operation Maximum number of stations in simultaneous operation 8 Stations Stations 4 Stations Z8-BSB 1 pc. 3M-K1YL-D31C 4 pcs. (Stations 1 to 4) 13M-K1YL-D31C 4 pcs. (Stations to 8) The stations are sequentially numbered. When viewed from the side of the vacuum ports, the far left station is designated as station 1. Left acuum port ka MODE SET1 SET2 ka MODE SET1 SET2 ka MODE SET1 SET2 ka MODE SET1 SET2 3M-K1YL-D31C ka MODE SET1 SET2 ka MODE SET1 SET2 ka MODE SET1 SET2 1 2 3 4 7 8 ka MODE SET1 SET2 13M-K1YL-D31C Right ilot exhaust port location B Both sides Exhaust S Silencer (Both sides) Supply port location B Both sides Flow Characteristics/Exhaust Characteristics Exhaust Characteristics Maximum vacuum pressure (ka) Maximum vacuum pressure (ka) -0 Maximum vacuum pressure 20 1 Air consumption Maximum suction flow Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) 0 0.1 0.2 0.3 0.4 0. 0. 0 2 4 8 Supply pressure (Ma) Suction flow (l/min(anr)) 7 Exhaust Characteristics -0 Maximum vacuum pressure Air consumption Maximum suction flow 0 0.1 0.2 0.3 0.4 0. 0. Supply pressure (Ma) 30 20 Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) 1 Exhaust Characteristics Flow Characteristics Maximum vacuum pressure (ka) Maximum vacuum pressure (ka) -0 7 Flow Characteristics -0 0 1 Suction flow (l/min(anr)) 1 Flow Characteristics ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Maximum vacuum pressure (ka) -0 Maximum vacuum pressure Air consumption Maximum suction flow 0 0 40 30 20 Maximum suction flow (l/min(anr)) Air consumption (l/min(anr)) Maximum vacuum pressure (ka) -0 0 0.1 0.2 0.3 0.4 0. 0. Supply pressure (Ma) 0 1 20 2 Suction flow (l/min(anr)) 13-9-3

Series Specifications Ejector Model Nozzle nominal diameter mm ø Maximum suction flow l/min(anr) Air consumption l/min(anr) Maximum vacuum pressure 0. 14 7 0.7 23 80 ka 1 1.0 22 4 Supply pressure range 0.3 Ma to 0. Ma Supply pressure Operating temperature range 0.3 Ma 0.43 Ma to 0 C Weight Single unit Note 1) 9 Switch and suction filter End plate assembly for manifold g 9 g 122 g Note 1) Including a 0.3 m connector for the supply and release valves. Including a 0.3 m connector for the supply and release valves and a 0. m connector for the switch. Calculation of weight for the manifold type (Single unit weight) x (Number of stations) + (Weight of end plate assembly for manifold) Example) Switch + 8 stations with suction filter 9 g x 8 + 122 g = 994 g Supply alve and Release alve Type (Refer to How to Order for solenoid Model valves on page 13-9-.) Fluid Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Lubrication Manual override Rated coil voltage ower consumption (current value) Electrical entry DC 0 AC 1 AC 200 AC 220 AC Standard type Q1- Normally closed type Low wattage type (0. W) Q1Y- Air, Inert gas 0. Ma 0.3 Ma to 0 C Not required Latching type Q1L- Normally open type 1-Q120- Non-locking push type / Lock type (tool type) ush-lock type Non-locking push type / Lock type (tool type) 12, 24 DC, 0, 1, 200, 220 AC 12, 24 DC 1 W 0. W 1 W 0. A ( ma) 0. A ( ma) 1.0 A ( ma) 1.1 A ( ma) 0. A ( ma) 0. A (.9 ma) 1.2 A ( ma) 1.3 A (.9 ma) Grommet L plug connector Grommet L plug connector With light/surge L plug connector With light/surge (With light/surge voltage suppressor) voltage suppressor ( voltage suppressor) acuum ressure Switch Model Refer to How to Order for vacuum pressure switches on page 13-9-. ( ) Rated pressure range Set pressure range Withstand pressure Fluid ower supply voltage Current consumption Ambient temperature range Ambient humidity range Withstand voltage Insulation resistance Switch output Maximum load current Maximum applied voltage Residual voltage Response time Hysteresis Display Display accuracy Output indicator light Analog output Note) Output voltage Linearity 1S-D31--AS 1S-D1--AS 1S-D32--AS 1S-D2--AS 0 to 0 ka 0 to 99 ka 0.2 Ma Air/Non-corrosive metal/non-combustible gas 12 to 24 DC ±% 3 ma or less [with power supply voltage of 24 DC and switch output ON (with no load)] to 0 C (with no freezing or condensation) 3 to 8 %RH in operation and saving (with no condensation) 00 AC for 1 min 0 MΩ or more (between live parts and pressure port at 00 DC) 1 NN output and analog output 1 N output and analog output 2 NN outputs 2 N outputs 80 ma (per output) 30 (for NN output) NN output: or less (at 80 ma inrush), N output: 1.2 or less (at 80 ma discharge) 2 ms or less 0 to 1% F.S. or less (adjustable) 2% F.S. or less (fixed) 0 to 1% F.S. or less (adjustable) 2% F.S. or less (fixed) 2-digit red LED ±3 %F.S. ±2 digits Lights up when output is ON (red LED). Lights up when output is ON (red for OUT1 and green for OUT2) (Only applicable to D31 and D.1) 1 to ±2.% F.S. or less ±0. F.S. or less 13-9-4

Compact acuum Ejector Series Construction Single unit Manifold t e r y o w q Component arts No. Description Material No. q w e r oppet valve assembly Nozzle Diffuser Release flow adjustment needle Aluminum Aluminum Aluminum t y u i o Solenoid valve Y L ilot valve Standard type (1W) DC low wattage type (0. W) Not available for AC type Latching positive common Actuation 1 Normally closed 1 Q1 2 0 u i Rated coil voltage 1 2 3 4 Q1 1 0 L How to Order L 0 AC 200 AC 1 AC 220 AC 24 DC 12 DC Replacement arts Description Material art no. Solenoid valve Filter element Sound absorbing material 1 (single unit) acuum pressure switch Sound absorbing material 2 (manifold) F F F Refer to How to Order below XT34--001-AS XT34--004 Refer to How to Order below XT34--003 Check valve K None With check valve Note) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used. Warning q Cannot be used for vacuum retention. w Use a release valve. (Without a release valve, the workpiece may not be released.) acuum pressure switch 1S D 31 C AS ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Actuation 2 Normally open Rated coil voltage 24 DC 12 DC ilot valve Standard type (1W) Electrical entry L plug connector L With 0.3 m lead wire L plug connector LO Without connector Grommet G With 0.3 m lead wire (Not available for latching and AC types.) Note) Mounting screws are attached. 31 32 1 2 Manual override Non-locking push type Latching: ush-lock type B Locking: Slotted type Note) Only the "" type is available with a latching type. Switch specifications 1 NN output and analog output 2 NN outputs 1 N output and analog output 2 N outputs Electrical entry Connector type C Lead wire length: 0. m Connector type CL Lead wire length: 3 m CN Without connector Note) Mounting screws are attached. 13-9-

Series Dimensions Type K1 11U-K1- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) 3 30. (74.9) Lead wire length (approx. 0.3 m) (49.) (Grommet type) (3.1) 13.1 32 17. 23 33 2 2.8 4-ø3. Mounting Bracket A (standard) Release valve 7 Release flow adjusting screw acuum pressure switch 7.3.9 71.9 ka MODE SET HYS acuum port ( port) (M x ) Circuit 11U-K1- D F DK Note 1) The above dimensions are for 11U-K1 -DC. In the case of 11U-K1-F, the overall length is 87.2. Dimensions marked with are those after bracket A is mounted. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the Type J1 11U-J1- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) Circuit (3.1) (AC type) 3. (3.1) 11U-J1- D F Bracket A (standard) 7 acuum pressure switch.9 71.9 Note 1) The above dimensions are for 11U-J1 L-DC. In the case of 11U-J1-F, the overall length is 87.2. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the ka MODE SET HYS acuum port ( port) (M x ) 13-9-

Compact acuum Ejector Series Dimensions Type K2 11U-K2- Release flow adjusting screw ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) Circuit 11U-K2- (8.4) F D DK 2.8 Bracket A (standard) 87.2 Release valve 7.3 acuum port ( port) (M x ) Note 1) The above dimensions are for 11U-K2 L-F. In the case of 11U-K2-D, the overall length is 7. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Type J2 11U-J2- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) (8.4) Bracket A (standard) 87.2 acuum port ( port) (M x ) Note 1) The above dimensions are for 11U-J2 L-F. In the case of 11U-J2-D, the overall length is 7. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the Circuit 11U-J2- F D 13-9-7

A A Series Dimensions Type Q1 11U-Q1- Release flow adjusting screw ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) (3.1) 3. B 0 Bracket A (standard) Release acuum pressure switch valve 2.8 7 7.3.9 71.9 ka MODE SET HYS acuum port ( port) (M x ) Circuit 11U-Q1- D F DK Note 1) The above dimensions are for 11U-G1 L-DC. In the case of 11U-Q1-F, the overall length is 87.2. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the Type Q2 11U-Q2- ilot exhaust port ( port) (M3 x 0., piping not required) Air supply port ( port) (M x ) (3.1) 3. 0 B Bracket A (standard) 7 acuum pressure switch.9 71.9 ka MOD E S E T HYS acuum port ( port) (M x ) Circuit 11U-Q2- D F Note 1) The above dimensions are for 11U-G2 L-DC. In the case of 11U-G2-F, the overall length is 87.2. The dimensions after bracket A is mounted are the same as those of the K1 type. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of, and ports are determined assuming the use of the Series dependant on their type and size. lease refer to the catalogue to confirm the 13-9-8

Compact acuum Ejector Series Dimensions Manifold type Z1-BSB 13M-- Supply port 2-ø3. ( Note 1) ) L2 (3.) (0.1) L1. 13 (itch) = 8 ( Note 1) ) 3 Attached washer 3. 2-R1.7 ilot exhaust port ( port) (One-touch fitting for applicable tubing diameter of ø4, piping not required) Common air supply port ( port) (One-touch fitting for applicable tubing diameter of ø8) 2.8 7 Release valve Release flow adjusting screw acuum pressure switch Attached washer (72.4).2 ka MO DE SET HYS ka MO DE SET HYS ka MO DE SET HYS ka MO DE SET HYS ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Dimensions n L1 L2 1 2 2 2 3 2 3 4 2 4 72 9 8. 82 7 92 28.8 7 8 2 81 n: Number of stations (mm) 8 9 112 7 8. 9 21 acuum port ( port) (M x ) Note 1) The above dimensions are for Z1-BSB. 13M-K L-DC. In the case of 13M--F, the overall length is 87.2. Dimensions marked with " " are those after the attached square bracket is mounted. Note 3) When the body is mounted, tighten with a torque of 0.±0.0 Nm. The pitches of ports are determined assuming the use of the Series KJ onetouch fittings. If used with other fittings, these may cause interference, dependant on their type and size. lease refer to the catalogue to confirm the sizes of the fittings to be used. Circuit 13M-K1-D 13M-K2-DK 13M-J1-F 13M-Q1-FK 13-9-9

Series Manifold Exploded iew 3 4 b 4 b view 2 a a Component arts No. q w e r t y Description Hexagon socket head cap screw End block R End block L Ejector assembly Ejector body gasket for manifold Exhaust block gasket art no. Refer to How to Order. 1R-1-BSB-AS 1L-1-BSB-AS 13M-- Note) -3-00 -3-009 Note) Refer to page 13-9- for detailed description of How to Order. 1 How to Order Hexagon Socket Head Cap Screw XT34 4 0 0 Number of stations 0 1 station 0 2 station 12 8 station Working rocedure Disassembly Loosen and remove the hexagon socket head cap bolts q. Assembly 1. Install the ejector body gasket for manifold t into the gasket groove of each ejector assembly r. Install the exhaust block gasket y around the projected part. 2. Install the exhaust block gasket y around the projected part of the end block R w. 3. Install the ejector body gasket for manifold t into the gasket groove of the end block L e. 4. Align the ejector assemblies r, end block (R) w, and end block (L) e using positioning pins (at the two a positions) and fasten with a hexagon socket head cap bolts q (2 pcs.) (with a tightening torque of 0. Nm±0.0 Nm). 13-9-