How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K. Note 6)
|
|
- Junior Young
- 5 years ago
- Views:
Transcription
1 Vacuum Unit RoHS Series 25A-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25A-ZK2 A 12 K 5 A 08 25A-ZK2 A q w e r t y u i Remains blank when option is not selected. q System/ody type System ody type Exhaust type A Silencer exhaust e Combination of supply valve and release valve Supply valve Release valve ote 5) K.C..C. Supply valve Release valve Ejector system Single unit Port exhaust Port size of exhaust port: ø8 (Metric) J R.C. Self-holding release valve linked ote 4).C. w ominal nozzle size System ominal size Ejector system ote 2) ø0.7 ø1.0 ø1.2 ø1.5 ote 2) Standard supply pressure for nozzle size 07 to 12 is 0.35 MPa, 15 is 0.4 MPa Manifold type is not available. ote 6) r Rated voltage Voltage 5 24 VDC 6 12 VDC 0 When e is ote 6) Rated voltage for the supply and release valve Only non-locking type is available for the manual override for K, J, R. ote 4) Self-holding type maintains vacuum by instantaneous energization (20 ms or more). Stopping the vacuum turns on the release valve. (signal to stop vacuum not needed) ote 5) When the digital pressure switch for vacuum with energy saving function is selected for t, select K for e Combination of supply valve and release valve. t Pressure sensor/digital pressure switch for vacuum specifications Pressure range Type Specifications [kpa] P T A C D E F H J K Q R S Pressure sensor Digital pressure switch for vacuum Digital pressure switch for vacuum with energy saving function ote 9) 0 to to 100 P 2 outputs 0 to 101 PP 2 outputs P 2 outputs 100 to 100 PP 2 outputs 100 to 100 Analog output 1 to 5 V Analog output 1 to 5 V P 1 output PP 1 output Unit selection function ote 7) SI unit only ote 8) Unit selection function ote 7) SI unit only ote 8) Unit selection function ote 7) SI unit only ote 8) Unit selection function ote 7) SI unit only ote 8) Unit selection function ote 7) SI unit only ote 8) Unit selection function ote 7) SI unit only ote 8) Pressure sensor Digital pressure switch for vacuum Digital pressure switch for vacuum with energy saving function Without pressure sensor/ Digital pressure switch for vacuum 115 ote 7) Unit selection function is not available in Japan due to new measurement law. ote 8) Fixed unit: kpa ote 9) When K, Q, R or S is selected, select K for e Combination of supply valve and release valve. Select W or 3 for y.
2 y Supply valve/release valve/digital pressure switch for vacuum connector specifications Type efor supply valve/release valve ote 10) tead wire with Connector type ead wire with connector ote 11) u Vacuum (V) port ote 16) connector for pressure switch/ sensor ote 13) 06 Metric size ote 14) type plug connector Port size ø6 One-touch fitting V ø8 One-touch fitting ote 12) ote 14) ote 16) Supply port size of single unit: ø6 ote 11) ote 15) Connector assembly ZK2 V W 3 ote 12) W With lead wire for switch with energy saving function 1 on-valve (without supply/release valve) When is selected for e Applicable valve type ote 15) ote 14) For double Red lack D With individual release pressure Use when supply pressure for vacuum release which pressure supply (PD) port type ote 18) is different from the ejector supply pressure is requested. J Vacuum break flow adjustment needle Round lock nut type Thicker than standard hexagon type. More suitable for hand tightening. Round lock nut improves operability when port exhaust type is used. K Vacuum break flow adjustment needle Screwdriver operation type Slotted type improves fine adjustment performance when port exhaust type is used. W With exhaust interference prevention valve ote 19), 20), 21) When ejectors are operated individually, exhausted air may flow backward from the V port of ejectors that are OFF. Exhaust interference prevention valve prevents back flow. ote) Refer to the WE catalog or the est Pneumatics o. 4 when mounting single unit to DI rail. q w e r t y u Single Unit and Options ote 22) lack Function/Application Use when a single unit is mounted to the floor in With one bracket for mounting a single unit an upright position is requested. (The part number for ordering only a bracket is ZK2-K1-A. olt (Mounting screw is nuts are included.) attached.) White Red P Type 300 mm 600 mm 1000 mm 2000 mm 3000 mm When is selected for both e and t (without supply/release valve, without switch, pressure sensor) Without option For single i Optional specifications/functions/applications ote 17) ead wire length Valve type K/R W (With supply valve and release valve) Valve type J S (Supply valve only) ote 10) Solenoid valve with light/surge voltage suppressor ote 11) Standard lead wire length for solenoid valve is 300 mm. ote 12) For lead wire lengths other than standard, select 1 or 3, and order the connector assembly desired. (Refer to the table on the right.) ote 13) Standard lead wire length for pressure sensor is 3 m. Standard lead wire length with connector for vacuum pressure switch and the lead wire length for switch with energy saving function is 2 m. ote 14) Select, 1, when the pressure sensor (P, T) is selected for t Pressure sensor/digital pressure switch for vacuum specifications. Since only grommet type is available for the pressure sensor, sensor without lead wire cannot be selected. ote 15) Select when no vacuum pressure switch, pressure sensor, or vacuum pressure switch with connector without lead wire is used. A i D J K 5 K A J 6 to to ZK2 12 R ote 22) When J or is selected for e Combination of Supply Valve and Release Valve, D, J or K cannot be selected for i Optional Specifications/Functions/Applications. For options not in the table, please contact SMC. racket PD port Vacuum break flow adjustment needle Vacuum break flow adjustment needle Exhaust interference prevention valve ote 17) When more than one option is selected, list the option symbols in an alphabetical order. Example) -J ote 18) Use One-touch fittings or barb fittings with O.D. ø8 or less for piping. (Recommended fitting: KQ2S23-M3) ote 19) To prevent backflow of the exhaust air, not for holding vacuum. This option does not completely stop the backflow of the exhaust air. Select port exhaust type depending on purpose. ote 20) When J is selected for e Combination of supply valve and release valve and W (exhaust interference prevention valve type) is selected for i Optional specifications/functions/applications, install a release valve or vacuum breaker. ote 21) When K, Q, R, or S is selected for t Pressure sensor/digital pressure switch for vacuum specifications, the exhaust interference prevention valve is provided. So, it is not necessary to select W. Specifications and dimensions for the 25A-series are the same as standard products. 116 Electric Fluid Control Detection Fittings/Flow Air Filters/Pressure Clean Air Preparation Vacuum Rotary Control Control Air Filters Air rippers PV: Air pressure supply port/port for vacuum source (Vacuum pump) PS: Pilot pressure supply port PD: Individual release pressure supply port V: Vacuum port EXH: Exhaust port PE: Pilot pressure exhaust port Related Directional Products Air Cylinders Control Valves 25A-ZK2 Auto Vacuum Unit Series
3 Series 25A-ZK2 Replacement Parts/How to Order Vacuum pressure switch assembly 25A ZK2 ZS E A M A q w e r q Rated pressure range and function E 0 to 101 kpa Vacuum pressure switch F 100 to 100 kpa Pressure switch with V 100 to 100 kpa energy saving function w Output specifications A P PP e Unit specifications Unit selection function M SI unit only ote 2) Unit selection function is not available in Japan due to measurement law. ote 2) Fixed unit: kpa r ead wire with connector With lead wire Open collector 2 outputs Open collector 1 output When q is E or F For vacuum pressure switch, ead wire with connector (ength 2 m) When q is V For switch with energy saving function, ead wire with connector (ength 2 m) ead wire with connector for vacuum pressure switch (When individual lead wire is necessary, order with the part number below.) ead wire with connector for vacuum pressure switch ZS 39 5 ead wire with connector for switch with energy saving function ZK2 W A 20 A Pressure sensor assembly ZK2 1 3 Output specifications A P open collector PP open collector 25A PS 1 A Rated pressure range and specifications 0 to 101 kpa, Output: 1 to 5 V, Accuracy: ±2% F.S. or less 100 to 100 kpa, Output: 1 to 5 V, Accuracy: ±2% F.S. or less 117
4 Auto Electric Fluid Control Detection Fittings/Flow Control Air Filters/Pressure Control Clean Air Filters Air Preparation Vacuum Air rippers Rotary Related Products Air Cylinders Directional Control Valves 118
5 Space Saving Vacuum Ejector Series 25A-ZQ [Option] ote) CE-compliant: For DC only. How to Order Ejector Unit 25A ZQ1 05 1U K1 5 EA q w e r t y u i o!0!1!2!3!4 Series compatible with secondary batteries q ozzle nominal size w Exhaust type ø0.5 ø0.7 ø1.0 1U 3M With silencer for single unit With silencer for manifold e Solenoid valve combination (Refer to Table (1).) K1 K2 J1 J2 Q1 Q2 1 2 Table (1) Combination of Solenoid Valve, Pilot Valve and Power Supply Voltage Combination no. q w e r t y u i o!0 Supply valve ormally open ormally open atching positive common atching positive common atching negative common atching negative common Solenoid valve combination symbol K1 K1 K2 J1 J1 J2 Q1 Q2 1 2 Pilot valve symbol Vacuum release valve In cases when K2 or J2 (supply valve normally open) is selected for the solenoid valve combination, when vacuum is stopped for long periods of time (10 minutes or more), do not continue to energize the supply valve, and shut off the air supply. 100 AC Applicable power supply voltage (V) 200 AC r Pilot valve (Refer to Table (1).) 110 AC Combinations q to!0 in the above table are the only possible options. ote 2) Standard (DC: 1 W) ote 2) DC low wattage type (0.5 W) ote 2) Avoid energizing the solenoid valve for long periods of time. (Refer to Design and Selection on Specific Product Precautions.) 220 AC 24 DC 12 DC t Solenoid valve rated voltage (Refer to Table (1).) VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC CE-compliant CE-compliant products are not available for 1, 2, 3 and
6 Space Saving Vacuum Ejector Series 25A-ZQ y Electrical entry O -type plug connector, with 0.3 m lead wire, with light/surge voltage suppressor -type plug connector, without connector, with light/surge voltage suppressor ote 4) u Manual override Directional Control Valves on-locking push type atching type: Push-locking type ocking type (Q1/Q2/1/2: ot applicable) ote 4) atching type supply valve: Available in only. In this case, the supply valve and release valve come with a push-locking type. Air Cylinders Related Products Rotary rommet, with 0.3 m lead wire (atching/ac type: ot applicable) Air rippers ote 5) i Vacuum pressure switch suction filter EA E EC EE FA F FC FE F 0 to 101 kpa/p open collector 2 outputs, with suction filter 0 to 101 kpa/pp open collector 2 outputs, with suction filter 0 to 101 kpa/p open collector 1 output + analog voltage, with suction filter 0 to 101 kpa/pp open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/p open collector 2 outputs, with suction filter 100 to 100 kpa/pp open collector 2 outputs, with suction filter 100 to 100 kpa/p open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/pp open collector 1 output + analog voltage, with suction filter Suction filter only ote 5) The filter included in this product is of an simple type, and will become clogged quickly in environments with high quantities of dust or particulates. Please make additional use of an air suction filter of the ZFA, ZF or ZFC series. Warning The filter case of this suction filter is made of nylon. Contact with alcohol or similar chemicals may cause it to be damaged. Also, do not use the filter when these chemicals are present in the atmosphere. ote 8)!1 Check valve K With check valve ote 8) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used. However, depending on usage conditions, it does not always suppress air overflow to the desired extent. During usage, please inspect thoroughly with actual machine. Also, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejector s exhaust unit. Warning q Cannot be used for vacuum retention. w Use a release valve. (Without a release valve, a workpiece may not be released.)!2 Fitting (V port) 0!3 Fitting (P port) 0 Applicable tubing O.D. Without fitting (M5 x 0.8) Applicable tubing O.D. Object spec. Without port Manifold Without fitting (M5 x 0.8) Single unit o Vacuum pressure switch unit specifications!0 Vacuum pressure switch lead wire specifications!4 CE-compliant CE-compliant Specifications and dimensions for the 25A-series are the same as standard products. M P ote 6) With unit switching function ote 7) Fixed SI unit ote 6) With unit switching function (Initial value psi) ote 6) Under the ew Measurement aw, sales of switches with the unit switching function are not allowed for use in Japan. ote 7) Fixed unit: kpa Without connector ead wire with connector (ead wire length 2 m) With connector cover Q ote) CE-compliant: For DC only. 120 Vacuum Air Preparation Clean Air Filters Air Filters/Pressure Control Fittings/Flow Control Detection Fluid Control Electric Auto
7 Series 25A-ZQ How to Order 25A ZZQ1 07 S C Manifold umber of stations ote) 01 1 station 02 2 stations Specifications and dimensions for the 25A-series are the same as standard products stations ote) umber of stations varies according to nozzle nominal size during simultaneous operation. Maximum umber of Stations in Simultaneous Operation ozzle Maximum number nominal of stations in simultaneous size operation ø0.5 8 stations ø0.7 6 stations ø1.0 4 stations Air pressure supply (P) port position oth sides S Exhaust With silencers (oth sides) Vacuum release pressure supply port (PD port) (Release pressure is supplied from the P port.) Provided C (Air can be alternatively supplied from the P port.) 121
8 Space Saving Vacuum Ejector Series 25A-ZQ How to Order Solenoid valve Actuation 1 25A ZQ1-VQ A ZQ1-VQ Actuation 2 ormally open Pilot valve Standard (1 W) Pilot valve Solenoid valve rated voltage 5 24 VDC 6 12 VDC Standard (DC: 1 W) DC low wattage type (0.5 W) AC type: ot applicable atching positive common atching negative common Manual override ote) Solenoid valve rated voltage VAC (50/60 Hz) VAC (50/60 Hz) VAC (50/60 Hz) VAC (50/60 Hz) 5 24 VDC 6 12 VDC on-locking push type atching type: Push-locking type ocking type ote) atching type: Available in only Electrical entry ote) -type plug connector, with 0.3 m lead wire -type plug connector, O without connector rommet, with 0.3 m lead wire (atching/ac type: ot applicable) ote) Mounting screws are attached. Directional Control Valves Air Cylinders Related Products Rotary Air rippers Vacuum Vacuum pressure switch EA E EC EE FA F FC FE 25A ZQ1-ZS Vacuum pressure switch specifications 0 to 101 kpa/p open collector 2 outputs, with suction filter 0 to 101 kpa/pp open collector 2 outputs, with suction filter 0 to 101 kpa/p open collector 1 output + analog voltage, with suction filter 0 to 101 kpa/pp open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/p open collector 2 outputs, with suction filter 100 to 100 kpa/pp open collector 2 outputs, with suction filter 100 to 100 kpa/p open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/pp open collector 1 output + analog voltage, with suction filter Vacuum pressure switch unit specifications With unit switching function ote 2) M Fixed SI unit With unit switching function P (Initial value psi) Under the ew Measurement aw, sales of switches with the unit switching function are not allowed for use in Japan. ote 2) Fixed unit: kpa Vacuum pressure switch lead wire specifications Without connector ead wire with connector (lead wire length 2 m) With connector cover Check valve K With check valve A Fitting (V port) Applicable tubing O.D. 0 Without fitting (M5 x 0.8) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used, but it is incapable of completely preventing overflow. During usage, please inspect thoroughly with actual machine. Also, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejector s exhaust unit. Warning q Cannot be used for vacuum retention. w Use a vacuum release valve. (Without a vacuum release valve, the workpiece may not be released.) ead wire with ote connector part no. ead wire length 2 m ZS-39-5 (With connector cover) Air Preparation Clean Air Filters Air Filters/Pressure Control Fittings/Flow Control Detection Fluid Control Electric Specifications and dimensions for the 25A-series are the same as standard products. Auto 122
9 Space Saving Vacuum Pump System Series 25A-ZQ [Option] ote) CE-compliant: For DC only. How to Order Vacuum pump unit 25A ZQ1000 U K1 5 Series compatible q w e r t y u i o!0!1!2 with secondary batteries q ody type EA U M For single unit For manifold w Solenoid valve combination (Refer to Table (1).) K1 K2 J1 J2 Q1 Q2 1 2 Supply valve ormally open ormally open atching positive common atching positive common atching negative common atching negative common Vacuum release valve The air in the adsorption section of this product is not released to the atmosphere at the vacuum suspension state. As for K1, K2, Q1 and 1, use the vacuum release valve when a workpiece is detached. Concerning J1, J2, Q2 and 2, devise the circuit for the vacuum release additionally when a workpiece is detached. In cases when K2 or J2 (supply valve normally open) is selected for the solenoid valve combination, when vacuum is stopped for long periods of time (10 minutes or more), do not continue to energize the supply valve, and shut off the air supply. e Pilot valve (Refer to Table (1).) r Solenoid valve rated voltage (Refer to Table (1).) ote 2) Standard (DC: 1 W) DC low wattage type (0.5 W) ote 2) VAC (50/60 Hz) CE-compliant ote 2) Avoid energizing the solenoid VAC (50/60 Hz) valve for long periods of time VAC (50/60 Hz) (Refer to Specific Product VAC (50/60 Hz) Precautions; Caution on Design and Selection.) 5 24 VDC 6 12 VDC CE-compliant products are not available for 1, 2, 3 and 4. Table (1) Combination of Solenoid Valve, Pilot Valve and Rated Voltage Combination Solenoid valve Pilot valve no. combination symbol symbol 100 AC 200 AC q w e r t y u i o!0 K1 K1 K2 J1 J1 J2 Q1 Q2 1 2 Combinations q to!0 in the above table are the only possible options. 123 Applicable power supply voltage (V) 110 AC 220 AC 24 DC 12 DC
10 Space Saving Vacuum Pump System Series 25A-ZQ t Electrical entry O -type plug connector, with 0.3 m lead wire, with light/surge voltage suppressor Directional Control Valves -type plug connector, without connector, with light/surge voltage suppressor ote 4) y Manual override on-locking push type atching type: Push-locking type ocking type (Q1/Q2/1/2: ot applicable) ote 4) atching type supply valve: Available in only. In this case, the supply valve and release valve come with a push-locking type. Air Cylinders Related Products Rotary rommet, with 0.3 m lead wire (atching/ac type: ot applicable) Air rippers ote 5) u Vacuum pressure switch suction filter EA E EC EE FA F FC FE F 0 to 101 kpa/p open collector 2 outputs, with suction filter 0 to 101 kpa/pp open collector 2 outputs, with suction filter 0 to 101 kpa/p open collector 1 output + analog voltage, with suction filter 0 to 101 kpa/pp open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/p open collector 2 outputs, with suction filter 100 to 100 kpa/pp open collector 2 outputs, with suction filter 100 to 100 kpa/p open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/pp open collector 1 output + analog voltage, with suction filter Suction filter only ote 5) The filter included in this product is of an simple type, and will become clogged quickly in environments with high quantities of dust or particulates. Please make additional use of an air suction filter of the ZFA, ZF or ZFC series. Warning The filter case of this suction filter is made of nylon. Contact with alcohol or similar chemicals may cause it to be damaged. Also, do not use the filter when these chemicals are present in the atmosphere.!0 Fitting (V port) 0 ote 8) Applicable tubing O.D. Without fitting (M5 x 0.8) ote 8)!1 Fitting (PS / PV port) 0 Applicable tubing O.D. Without port Without fitting (M5 x 0.8) Part no. Object spec. Manifold Single unit i Vacuum pressure switch unit specifications M P ote 6) With unit switching function ote 7) Fixed SI unit ote 6) With unit switching function (Initial value psi) ote 6) Under the ew Measurement aw, sales of switches with the unit switching function are not allowed for use in Japan. ote 7) Fixed unit: kpa o Vacuum pressure switch lead wire specifications Without connector ead wire with connector (ead wire length 2 m) With connector cover Vacuum Air Preparation Clean Air Filters Air Filters/Pressure Control Fittings/Flow Control Detection!2 CE-compliant Q CE-compliant ote) CE-compliant: For DC only. ote 8) For filter only (Without vacuum pressure switch) When neither V port fitting nor PS/PV port fitting are needed, enter nothing or 00 in the dotted line How to Order. Fluid Control Electric Specifications and dimensions for the 25A-series are the same as standard products. 124 Auto
11 Series 25A-ZQ How to Order 25A Manifold ZZQ umber of stations 01 1 station 02 2 stations 08 8 stations Vacuum pressure supply port (PV port) Port location (Refer to Table (1).) R eft side Right side Table (1) Air Pressure Supply Port ocation on the Manifold Manifold PD port Port location (eft side) R (Right side) (eft side) C R (Right side) PS ote) eft PV PD Right PS PV ote) PD ote) The position of each port is shown as right and left sides viewed from the front side of the vacuum port. Release pressure is commonly supplied from the PS port. PS: Pilot pressure supply port, PV: Vacuum pressure supply port, PD: Release pressure supply port C Release pressure supply port (PD port) (Release pressure is supplied from the PS port.) Provided (Air can be alternatively supplied from the PS port.) Specifications and dimensions for the 25A-series are the same as standard products. 125
12 Space Saving Vacuum Pump System Series 25A-ZQ How to Order Solenoid valve 25A 25A Actuation 1 ZQ1 VQ ZQ1 VQ Actuation 2 ormally open Pilot valve Standard (1 W) Pilot valve Solenoid valve rated voltage 5 24 VDC 6 12 VDC Standard (DC: 1 W) DC low wattage type (0.5 W) AC type: ot applicable atching positive common atching negative common Manual override ote) Solenoid valve rated voltage VAC (50/60 Hz) VAC (50/60 Hz) VAC (50/60 Hz) VAC (50/60 Hz) 5 24 VDC 6 12 VDC on-locking push type atching type: Push-locking type ocking type ote) atching type: Available in only Electrical entry ote) -type plug connector, with 0.3 m lead wire -type plug connector, O without connector rommet, with 0.3 m lead wire (atching/ac type: ot applicable) ote) Mounting screws are attached. Directional Control Valves Air Cylinders Related Products Rotary Air rippers Vacuum Vacuum pressure switch EA E EC EE FA F FC FE 25A ZQ1 ZS Vacuum pressure switch specifications 0 to 101 kpa/p open collector 2 outputs, with suction filter 0 to 101 kpa/pp open collector 2 outputs, with suction filter 0 to 101 kpa/p open collector 1 output + analog voltage, with suction filter 0 to 101 kpa/pp open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/p open collector 2 outputs, with suction filter 100 to 100 kpa/pp open collector 2 outputs, with suction filter 100 to 100 kpa/p open collector 1 output + analog voltage, with suction filter 100 to 100 kpa/pp open collector 1 output + analog voltage, with suction filter Vacuum pressure switch unit specifications With unit switching function ote 2) M Fixed SI unit With unit switching function P (Initial value psi) Under the ew Measurement aw, sales of switches with the unit switching function are not allowed for use in Japan. ote 2) Fixed unit: kpa Vacuum pressure switch lead wire specifications Without connector ead wire with connector (ead wire length 2 m) With connector cover Check valve K With check valve A Fitting (V port) Applicable tubing O.D. 0 Without fitting (M5 x 0.8) The check valve has a function to prevent the exhaust air from the silencer overflowing to the vacuum port side when a manifold is used, but it is incapable of completely preventing overflow. During usage, please inspect thoroughly with actual machine. Also, in order to completely prevent the overflow of exhaust air, leave plenty of space between the check valve unit and adjacent ejector to avoid interference from the ejector s exhaust unit. Warning q Cannot be used for vacuum retention. w Use a vacuum release valve. (Without a vacuum release valve, the workpiece may not be released.) ead wire with ote connector part no. ead wire length 2 m ZS-39-5 (With connector cover) Air Preparation Clean Air Filters Air Filters/Pressure Control Fittings/Flow Control Detection Fluid Control Electric Specifications and dimensions for the 25A-series are the same as standard products. Auto 126
How to Order Single Unit 25A-ZK2 A 12 N 0 N N 08. e Combination of supply valve Note 3) and release valve. Note 5) K
Vacuum Unit RoHS Series 25-ZK2 How to Order Single Unit Ejector System (with Valve) Ejector System (without Valve) 25-ZK2 12 K 5 08 25-ZK2 12 0 08 q w e r t y u i Remains blank when option is not selected.
More informationSpace Saving Vacuum Ejector/Vacuum Pump System
Space Saving acuum Ejector/acuum ump System Series Current 21.6 mm mm Width mm [Option] Weight 9 g Single unit with vacuum pressure switch and suction filter ZK2 ZR Z Z ZM ZL -X267 ZU Ejector.2 ump System.118
More informationSpecialized Product. Fieldbus-compatible Vacuum Unit. Applicable to 6 types of communication networks. Applicable to 4-station/8-station manifolds
Contact our sales office for delivery dates and prices as this is a special model. P.G. information Fieldbus-compatible Vacuum Unit Features Applicable to 6 types of communication networks Applicable to
More informationSpace Saving Vacuum Ejector / Vacuum Pump System
CT.US0-1'-UK Space Saving acuum jector / acuum ump System Conventional ZX 21. mm mm ZQ Series ZQ Width mm Weight 9 g Single unit with vacuum pressure switch and suction filter jector ump System NW asy-to-use
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More informationCompact Vacuum Ejector
Compact acuum Ejector Series ZA Total length Total width 7.9 mm 9.9 mm Total height. mm Response time 0 ms Response time for up to 0 ka Nozzle diameter: ø0.7 iping: ø/ø. x 0 mm Able to install on the moving
More informationVacuum Release Valve with Restrictor
INFORMATION Series SY3/5 Plug-in Only for External Pilot Vacuum Release Valve with Vacuum suction and release can be controlled with a single valve! PE Pilot EH port Flow rate adjustment of release air
More informationBase Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer
Base Mounted Metal Seal/Rubber Seal VQ Built-in silencer, direct exhaust Space-saving profile All pilot valves are compactly mounted on one side. The space-saving design of mounting all fittings on one
More informationVacuum Ejector. Series ZM
Ejector Series All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More informationCompact Vacuum Unit Ejector/Vacuum Pump System. 46 g. New. 17% reduced 21% 10 mm mm mm. Series ZB. Response time of the valve: 5 ms
Compact acuum Unit Ejector/acuum Pump System New RoHS Quick response Compact/ Lightweight Response time of the : ms acuum response time: 8 ms (Shortened by %; Comparison with other SMC products) Conditions:
More informationCompact Vacuum Unit. 46 g Single unit weight. New RoHS. 17% reduced 21% Ejector/Vacuum Pump System. 10 mm mm mm.
Compact acuum Unit Ejector/acuum Pump System New RoHS Quick response Compact/ Lightweight Response time of the : ms acuum response time: 8 ms (Shortened by %; Comparison with other SMC products) Conditions:
More informationEnergysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in)
Compact acuum Unit Ejector/acuum Pump System Quick response Compact/ Lightweight Response time of the : 5 ms acuum response time: 28 ms (Shortened by 25%; Comparison with other SMC products) Conditions:
More informationSeries ZM Applications
Ejector Series ZM All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More informationQ1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.
Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus
More informationSeries ZQ. Compact Vacuum Ejector. One-touch fitting. Digital vacuum pressure switch With LED display. ZX ZR ZM ZH ZU ZL ZY ZQ ZF ZP ZCU AMJ Misc.
Compact acuum Ejector Series Body width mm, Weight9 g (Single unit with vacuum pressure switch and suction filter) Conventional 21.mm mm One-touch fitting ZR ZM ZH ZU ZL ZY ZF Z ZCU AMJ Misc. Digital vacuum
More informationEnergy saving ejector
acuum Unit ZK2 Series acuum acuum ump RoHS Energy saving ejector Digital pressure switch for vacuum with energy saving function cuts supply air when the pressure reached the desired vacuum. ir consumption
More informationSeries ZM Applications
Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More informationLarge Size Vacuum Module:
arge Size acuum Module: Ejector System/acuum ump System arge suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø., ø., ø.5, ø.8, ø2. acuum module suitable for handling
More information13 msec (at 500 mm )/18.5 msec (at 1000 mm )
Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without
More informationSeries ZM Applications
Ejector [Option] ll in One! Built-in suction filter and silencer ir supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) pressure switch (solid state, diaphragm)
More informationVacuum Ejector. Series ZM Applications
Ejector Series ZM All in One! Built-in suction filter and silencer Air supply valve for generating a vacuum release valve (equipped with a flow volume adjustment valve) switch (solid state, diaphragm)
More informationVacuum / Release Unit
Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow
More informationSpecifications. Fluid Ambient and fluid temperature ( C)
Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication
More informationVacuum Unit Vacuum Ejector Vacuum Pump System RoHS Energy saving ejector Air consumption % reduction More efficient eject
acuum Unit acuum Ejector acuum ump System New RoHS Energy saving ejector Digital pressure switch for vacuum with energy saving function cuts supply air when the pressure reached the desired vacuum. Air
More informationVacuum System Peripherals
Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control
More informationVacuum Module. Series ZX. Ejector System/Vacuum Pump System
Vacuum Module Series ZX Ejector System/Vacuum Pump System For electronic components and precision components up to 0 g Modular design Customized application function through selection of module components.
More informationSeries AV2000/3000/4000/5000
Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU
More informationVacuum Equipment. Application. Series
Equipment Series Application Page ejector In-line vacuum ejector Multistage ejector ejector with check valve Pad with check valve ejector for water soluble coolant removal ZH ZU ZL1/2 (Special order product)
More informationD-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector
Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),
More information3 Port Solenoid Valve Direct Operated Poppet Type
3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage
More information3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.
Port Solenoid Valve Series VQ 00 Unprecedented high speed, stable response, and extra-long service life. ON:.ms, OFF: ms, Dispension accuracy ±ms (With indicator light and surge voltage suppressor; supply
More informationLarge Size Vacuum Module:
Large Size acuum Module: System/acuum Pump System Large suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for handling
More informationSeries VP3145/3165/3185
Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to
More information2.26 S OLENOID VALVES S ERIES VQ1000
2.26 S OLENOID VALVES 5 PORT M ETAL S EAL/RUBBER S EAL U LTRA H IGH S PEED S OLENOID VALVE High Speed Response from new Solenoid Design. Long Life: Over 200 Million Cycles can be with Patent Pilot Valve
More information5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal
Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More information5 Port Solenoid Valve Direct Operated Poppet Type. Specifications
Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W
More informationSoft Start-up Valve. AV2000/3000/4000/5000 Series
Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationLarge Size Vacuum Module:
Large Size acuum Module: System/acuum Pump System Z Large suction flow rate, suitable when used with large size pads or multiple pads. Nozzle dia. ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for
More information3 Port Air Operated Valve
Port Air Operated Valve 00/500/00 Series RoHS 1555 00/500/00 Series Model Selection by Operating Conditions q Air Operated Valve: Single Unit Series Sonic conductance C [dm /(s bar)] Type of actuation
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More information3 Port Solenoid Valve
Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000
More informationI N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications
I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000
More informationHow to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications
For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More informationVQ1000. How to Order Manifold. Kit type
- - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold
More informationSingle Valve/Sub-plate Type IP67 Compliant 90-SV Series
Single Valve/Sub-plate Type IP7 Compliant -SV Series SV 00 W U aterial restriction Series -SV000 -SV000 Thread type c F G N NPT T NPTF A B SOL.a SOL.a Type of actuation position single (EA) (P)(EB) position
More informationSeries VP3145/3165/3185
Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes
More informationEjector Valve Unit Series ZYY/ZYX
Ejector Valve Unit Series ZYY/ZYX Series ZYY3 (Solenoid valve: SY3) Nozzle diameter: ø.7, ø1. Type S: Standard type L: Large flow type Ejectors and solenoid valves can be mounted on the same manifold.
More information10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection
Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection
More informationAir Suction Filter. Series ZF. Prevent from occurring vacuum equipment trouble due to dust from vacuum pad ZFA ZFB ZFC
Air Suction Filter Series ZF Prevent from occurring vacuum equipment trouble due to dust from vacuum pad Series ZFA ZF Universal joint type Features Long maintenance cycle type (Large filter surface) Adaptable
More informationLCD Readout Digital Pressure Switch
LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics The ZSE3/E3 series is to be discontinued. We recommend you consider using the Z/E10 series or the
More informationSeries 10-ZSE40A(F)/10-ISE40A
Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA
More informationManifold Specifications
Series 00 Manifold Specifications Manifold Specifications Model Manifold type P(SUP)/R(EXH) Valve stations A port porting specifications Port size For internal pilot For external pilot Location Direction
More informationOption. Nil. 02 to 24 B Note 2) K Note 3) N. Note 1) Cable/SI unit specifications
Series -SQ00 Port Solenoid Valve Plug-in Unit [Option] How to Order Manifold Electrical entry F kit D-sub connector kit P kit SSQ 08 FD Kit type Flat ribbon cable connector kit J kit Flat ribbon cable
More informationBody width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.
High speed coil with stable response times ON: 4ms, OFF: 2ms, Dispersion accuracy: ±1ms (With light and surge voltage suppressor at a supply pressure of 0.5MPa, subject to clean, dry air) 4 Port Direct
More informationBase Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC
Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS3000 Model position 3 position
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible
More informationManifold Specifications
Specifications Specifications Base mounted VVFR-01 VVFR- VVFR-0 Wiring With terminal block With multi-connector With D-sub connector Grommet terminal DIN terminal Grommet Grommet terminal Conduit terminal
More information5 Port Solenoid Valve. High speed response type) Series. Body ported VQZ1 2 VQZ2 2 VQZ3 2 VQZ1 5 VQZ2 5 VQZ3 5. Base mounted
Metal Seal ort Solenoid Valve Series // Rubber Seal.. ower consumption:. W/. W Compact, High Flow Series Valve width (mm) (Standard) (High pressure type, High speed response type) ody ported ase mounted
More informationSeries SY3000/5000/7000
Type20P 5 Port Solenoid Valve ody Ported Manifold ar Stock Type/Flat Ribbon Cable Series SY3000/5000/7000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 5 20P 05 Manifold series 3 SY3000
More information2-Color Display High-Precision Digital Pressure Switch
2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts
More informationVacuum Ejector with Solid State Timer
Vacuum Ejector with Solid State Timer Incorporates solid state timer function for release valve control (Timer setting with PLC is unnecessary) Timing Chart OFF Suction command ON Suction output OFF ON
More informationMULTISTAGE MICRO EJECTORS
MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]
More informationSeries VQ Port Solenoid Valve
Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors
More informationMULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle
More informationLarge Size Vacuum Module: Ejector System/Vacuum Pump System. Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0
Large Size acuum Module: Ejector System/acuum Pump System Nozzle size (mm): ø1.0, ø1.3, ø1.5, ø1.8, ø2.0 acuum module suitable for handling workpieces of 0.5 to 5 kg. Z MJ 13-3-1 Large Size acuum Module:
More informationPower Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.
Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control
More information0.35 W (Without light)
Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model 2 position 3 position
More informationVacuum pump system type
type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated
More informationManual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry
Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body
More informationVacuum Pad with Ejector
IFORMTIO Vacuum ad with Ejector ad Diameter: ø63, ø8 RoHS Ejector and pad are integrated. Space saving and reduced piping labor! Bellows type with groove Two-stage ejector More efficient ejector Suction
More information3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.
3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118
More informationSeries SY3000/5000/7000
Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread
More information3 Port Solenoid Valve
Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly
More information5 Port Solenoid Valve
ort Solenoid Valve Metal Seal / Rubber Seal ower consumption:..w/..w ower consumption:. W/. W Compact, High Flow (Standard) (High pressure type, High speed response type) ody ported ase mounted Series
More informationExhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)
5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust
More informationManifold Specifications Stacking Type
Specifications Stacking Type Keeps environmental air clean from pilot exhaust Use of the VV5FS- manifold can exhaust intensively the pilot exhaust gas to the base side, and can prevent environmental aggravation
More information4 Port Solenoid Valve Cassette Type Manifold Rubber Seal
Port Solenoid Valve Cassette Type Manifold Rubber Seal 7.mm (SJ000) SJ000 SJ000 Can be mounted together. 0mm (SJ000) Connector connection New New cable type manifold is added! New Additional options are
More informationExample. U side. Stations SY5000
45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported Series VFS2000 Model 2 position 3
More informationNew Concept Connector Type Manifold
New Concept Connector Type Manifold Series /000/3000/000 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration.
More informationSeries SJ3A6. Vacuum Release Valve with Restrictor P.86 P.90. D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510
Vacuum Release Valve with Restrictor Series SJ3A6 SJ Plug-in Type Connector Connection P.86 D-sub Connector Flat Ribbon Cable PC Wiring Serial Wiring: EX180 Serial Wiring: EX510 Non Plug-in Type Individual
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationElectro-Pneumatic Regulator Electronic Vacuum Regulator
Electro-Pneumatic Regulator Electronic Vacuum Regulator New Stepless control of air pressure proportional to an electrical signal Added Fieldbus compliant specifications to Series ITV//! Reduced wiring
More informationHow to Order L B. Pilot type. Nil. U side D side. Stations 3 2 1
Port Solenoid Valve Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Non plug-in manifold 0 0 S 60 Stations stations 0 stations SUP/EXH
More information9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!
Digital Pressure Switch Series ZSE1(F)/ISE1 Low profile 26.1mm 9.8 mm 13.5 mm 53.4 mm Reduced in depth! (Actual size) RoHScompliant Vertical mounting space reduced to approx.! 1 2 Position Detection Switch
More information3 Port 3 Position Valve
Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ø15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option
Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable
More informationPlug Lead Unit: Flip Type
Series ody orted lug Lead Unit: Flip Type For details about certified products conforming to international standards, visit us at www.smcworld.com. 0 Series Kit/Electrical entry/cable length F kit (D-sub
More informationElectro-Pneumatic Regulators. Electronic Vacuum Regulators
Electro-Pneumatic Regulator Electronic Vacuum Regulator New Reduced wiring Applicable Fieldbus protocols Compact & light Weight: g Note ) (ITV) Power consumption: 4 W Note ) or less Electro-Pneumatic Regulators
More information2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions
-Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color
More informationFieldbus System (Output device for driving 5 port solenoid valves)
Fieldbus System (Output device for driving port solenoid valves) New Compact 8mm (ctual size) Space-saving Installation IP67 RoHS EtherNet/IP added! For units with D-sub connector, and when connected to
More information