1 S86 M Quality System QMI is ccredited by: ISO 900 ertified utch ouncil for ccreditation Models 0/000 Regulators ata Sheet vailable Models 0 Series low pressure models have a maximum inlet pressure of and offer outlet pressures ranging from." w.c. to. 000 Series high pressure models allow a maximum inlet pressure of and outlet pressures ranging from. to. The 0 Series can be ordered as Full Relief, Partial Relief or No Relief Regulator as shown in the table. 000 Series Regulators are nonrelieving. oth models are available with Overpressure Shutoff, Underpressure Shutoff and monitor capabilities. Low Pres. Model imensions Numbers escription *E Standard Regulator.7" ".7" 6" 0." M Standard Monitor Regulator.7" ".7" 6" 0." 8 Partial Internal Relief Regulator.7" ".7" 6" 0." 8 Full apacity Internal Relief Regulator.7" ".7" 6" 0." 8 Underpressure Shutoff.7" ".7" 6" 0." 8 Underpressure Shutoff with Partial Internal Relief.7" ".7" 6" 0." 8 Underpressure Shutoff with Full Internal Relief.7" ".7" 6" 0." 8 Overpressure Shutoff with Partial Internal Relief.7" ".6" 9.87" 0." 8 Overpressure Shutoff with Full apacity Internal Relief.7" ".6" 9.87" 0." 8 Overpressure and Underpressure Shutoff with Partial Internal Relief.7" ".6" 9.87" 0." 8 Overpressure and Underpressure Shutoff with Full apacity Internal Relief.7" ".6" 9.87" 0." 88 Overpressure Shutoff.7" ".6" 9.87" 0." 88M Overpressure Shutoff with Monitor.7" ".6" 9.87" 0." 89 Overpressure and Underpressure Shutoff.7" ".6" 9.87" 0." High Pres. Model imensions Numbers escription *E 00 Standard Regulator 8.9" ".7" 6" 0." 00M Standard Monitor Regulator 8.9" ".7" 6" 0." 0 Underpressure Shutoff 8.9" ".7" 6" 0." 08 Overpressure Shutoff 8.9" ".6" 9.87" 0." 08M Overpressure Shutoff with Monitor 8.9" ".6" 9.87" 0." 09 Overpressure and Underpressure Shutoff 8.9" ".6" 9.87" 0." * 0" flange valve head is an option; contact Sales Office for information. Low Pressure High Pressure E apacity information can be found in ulletin S 8. E

2 merican Meter Regulator ssembly Positions Valve Head Position Valve Head Position STNR STNR STNR STNR Valve Head Position Valve Head Position STNR STNR OPSO Shutoff Springs " to 8" W P07 Red/Purple PSI to PSI 7007P076 Red/rown PSI to PSI 7007P077 Purple PSI to PSI 7007P078 Orange/Yellow PSI to 8 PSI 7007P079 Orange/Green * 8 PSI to PSI 7007P078 Orange/Yellow * PSI to 0 PSI 7007P079 Orange/Green * To achieve these ranges, reducing ring 766P00 must be used. Regulator ssembly Number VLVE HE POSITION * VLVE HE POSITION OPSO VENT POSITION ** ** ** * FOR MOELS USING OPSO ONLY. ** UNLESS OTHERWISE SPEIFIE, VLVE HE POSITION "" WILL E SUPPLIE. Regulator Springs." to 6" W.. 7P07 Red." to 8" W.. 7P08 Orange 8." to " W.. 7P09 Yellow." to 8" W.. 7P00 Green PSI to PSI 7P0 lue. PSI to. PSI 7P06 rown/lue PSI to PSI 7P0 rown/green PSI to PSI 7P0 lack/green Ordering Information Model number: See vailable Models table on front. onnection size: -/" screwed, " screwed, " flanged. Orifice size: /", /8", /", /8", /", 7/8", ", -/" Spring range: See Regulator Springs table. OPSO spring range, if required: See OPSO Shutoff Springs table. Regulator orientation: See above. MERIN METER 0 Welsh Road uilding One Horsham, P 90- U.S.. Phone: /8-0 Fax: /8-890 NIN METER 7 erry Road, West Milton, Ontario L9T X6 anada Phone: 90/878-6 Fax: 90/ Printed in U.S.. ore 0 /99

3 -/" Series 0 apacity ata SFH Gas 0. Specific Gravity 7P07." to 6" w.c. Set: 6" w.c. roop: " w.c. Max. ompound: " w.c. 7P09 8." to " w.c. Set: " w.c. roop: " w.c. 7P00." to 8" w.c. Set: roop: 6" w.c. 7P0 to Set: roop: 0.6,0,0, /,900,0,0,,000 0,80,0,,0,0, 70,70,0,80,0,0,0 700,0,0,900,700,700,00,70,0,0,0,0,,900,0,0,00,00,0,900,0,00,00,,0,700,,0,0,0,900,,700,,0,000,0,90,0,000 7,00 6,00 6,,0,0,000,0 0 7,0 6,0 6,000,000,0,000,0 9, 7,900 7,00 6,00,0,80,900 9,0 7,0 7,00 6,0,00,80,900 9,00 8,700 7,00 6,0,0,0 0 9,0 8,0 7,0 6,0,0,00,70, 9,000 7,700,900,80,0 0,700 8,900 8,,0,0,0 0,0 9,00 7,00,0,0,000 9,0 7,0,0 9,0 9,0,80,0 8,0 8,0,0,0,0,0,000 6,,0 7,0 9,0,900,0,0 6,0 8, 9,00,0,00,00,00 6,00 7,0 9,000,0,0,0, 6,00 7,0,,700,,0,0,0 6,00 70,00,0,900,0,000,80,0 0 0,0,,0,00,70,000,700,0 8,00 7,0 9,0,700,0,00,0 6,0 9,0,0,, 6, 7,0 8,0,0,900,00,0,900 6,0 7,00,000,0,,00 6,00 700,000,0,0,0,700,0,000,900,00,0, 9,00 8,,0,700,00, 9,0,0,0,700,0 9,00 7,00,0,0,00 9,0 7,,0,900,00 9,0,0,0 9,0,,0,700 8,00,000,0,700 8, 6,0,900,00,0,000,0 6,60,0,700,,00,000 7,00,0,900,0,0,0,70 900,000 9,0 8, 6,0,900,0 0,000 9,00 7,0,900,700,900,0 0,000 8,700 7,0 6,00,700,900,000 9,70 8,700 7,0 6,0,0,900,700,0 0,000 9,00 7,0,0,0 0,900,0,900 0,0 9,00 7,0,700,00,00,0,0 9,0,0,0,0,80,0, 9,00 6,000,0,0,900,700 0,900 7,,0,00,80,0 7,,0 6,0 6,000,00 9,0,700 9,0 8,00 7,00,000 9,0,0 6,000,0 8,900 7,700,0,0,0 8,0 8,0,,0,900,900,0 70 7,0,0,000,000,00,0 0,0,0,0,700,,00,00 0,000 7,900 9,700 6,0 8, 6,0 8,,0,0,0,0,000,0,0,00 0 9,00 7,0,0 9,70 6,00 7,0 6,00 7,0,0 6,000,00,0,000,80,0,00, 0,0 0,0,0,0 9,0 9,0,0,900 6,000,700 0,00 0,00,000,000 8,0 9,0 7,00 8,700,000,900 6,00,900,900 8,0,0 7,00 7,00,700 8,900,900,00,00 0,80 6,00,700 7,00 8, 6,000,00 0,0 6,00,700 7,00 8, -/" " 7/8" /" /8" /" /8" /",00,0,0,0,0,0,0 0 7P06 7,00,0,000,700,0,00,00 8,6 7,0 6,0,0,0,000,0. to. 9,090 8,0 6,0 6,700,0 Set:. 0,0 8,700 8,0 8,,900,0,0 roop: 0.,00,0 9,700 6,900,0,,00,0, 0, 7,0,0,0,700,00 9,0,0 0,00 6,0 7,00 For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line P08." to 8" w.c. Set: 7" roop: " Max. ompound: " w.c. 7P09 8." to " w.c. Set: " roop: " w.c. 7P0 to Set: roop: 0. 7P0 to Set: roop: ontact your merican Meter representative for inlet pressures above.

4 " Series 0 apacity ata SFH Gas 0. Specific Gravity For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO 7P07,00,0,00,0,00 /,0,0,900,000,0 00, 900,0,000,0,0,900,0,60,0." to 6" w.c. 8,900 6,0,,0,0,00,,0 Set: 6" w.c.,00 0,000 7,00,00,000,900, roop: " w.c. 6,00,000 0,0 8,0 6,00,0,000,60 Max. ompound: " w.c. 6,00 6,000 0,0 9,000 6,0,000,90 0 9,000,700,700,0,0,0 0,00,000 7,700,900 7,00 9,0,80,0,80 8,0 For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO 7P08,900,0,0,700,0,0 /,0,,00,0,000,0 00,00 70,0,0,0,700,0,0,0." to 8" w.c. 6,000,000,0,00, Set: 7" w.c.,000 0,000,000,000,900,000 roop: " w.c.,700, ,0 6,00,0,000,0 Max. ompound: " w.c. 7,00 6,000,000 9,000 6,0,000,900 9,00 0 9,000,00,000 7,0,0,00,000 0,0,00 7,0,900 7,00 9,0,0,0,0 8,0 For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO 7P09,0,,700,00,00,0,700,700,0,0,000 70,00 7,00,700,000,0,000 8." to " w.c. 7, 6,0,0,000,0,000 Set: " w.c.,000,0 0,00 8, 6,00,0,900,0 roop: " w.c. 9,000 6,000,000 0,0,0,0,900 0,0 7,900 0,0,000 7,0 0,000,0 7,0,0,700 9,000,0,00,0,0,700 8,00 For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO 7P09,700,00,0,,0,000,0, 900,0 70, 6,000,0,00,0,00,700,0,0 8." to " w.c. 0,0 7,0 6,00,0,0,0,00,0,000 Set: " w.c. 9,000,,0 0 9,0 7,0,0,000,0,0 roop: " w.c. 9,000 6,0,0 0,000 7,900,00,700, ,700,0 9,00 7,00,0,00 7,0,000 9,0,0,0,00,0 7,0 9,000,0,700 8, For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line. 8 ontact your merican Meter representative for inlet pressures above.

5 " Series 0 apacity ata SFH Gas 0. Specific Gravity For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO 0,000,00 7,700,0,0 6,900 0,900, ,0 0,0,000 7,00,000 7,900 0,00,000,000, 6,00 8,0 0,00,000,700 6, 7,0 0,0,0 7,0,0,700,0,0 6,700 9,0,0,,0,900,0,0,0,700,0 8,0 For Models With lue Holder Without OPSO For Models With Silver Holder Without OPSO For Models With Silver Holder With OPSO For Models With Red Holder With OPSO 7,0 6,000,0,00,0,0,0,0,000, 0,0 8, ,0 7,0,900,00,0,0,,0,0 0,0 7,0,0,700,900 9,,0 0,00 9,00 7,00,0,00 6,0, 9,0,0,0 7,0,00 6,700,0 7,00 9,000,0,0,0 8,0 For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO,0,0,900,00,700,00,0,00 0 9,000 7,0 6,0 0 6,00,0,,900,,0, 0,0 9,0 9,000 6,0,0,000,,0,0,00 0,00 8,0,00,0 9,0 7,00,00, 0,0 7,0,,0,700,700 7,0,000 9,00 6,0,00,700,900,0,0 8,900,0 8,0, 9,,0,0,0 6,0 8,00 For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO, 7,0 0,0,0,0,0 0,00,00,00,000 6,0 8,0,0 0 0,000,000 6,0 8, 0,0,0,000,000 6,0 8, 0,0,0,0,0 0,000 9,0,0,0 0,000 9,0,0,00,0,0 6,000 8,0 0,900,0 70,0,0,00,900,0 6,00 7,00 8, For Models With lue Holder Without OPSO For Models With Silver Holder With OPSO For Models With Silver Holder Without OPSO For Models With Red Holder With OPSO 6,0, 0,,000,0,,00,00,0 8,0 7,0,,0,000,0,000 9,00 0 8,700 8,700 6,00,0,0,00,,0,, 8,0 7,0,000,900,0,0,000 9,00 6,00,00,00 8,900,900,00 6,00,700 7,00 8, 7P00." to 8" w.c. Set: roop: 6" w.c. 7P0 to Set: roop: 0. 7P06. to. Set:. roop: 0. 7P0 to Set: roop: 0.6 7P0 to Set: roop: For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line. 9 ontact your merican Meter representative for inlet pressures above.

6 -/" Series 000 apacity ata SFH Gas 0. Specific Gravity " Series 000 apacity ata SFH Gas 0. Specific Gravity 7P00 / to Set: roop: 6" w.c. 7P0 to -/ Set: -/ roop: / 7P0 -/ to Set: roop: 7P0 to 0 Set: 0 roop: 7P0 0 to Set: roop: ll Models With lue Holder,900,0,0,000,900,900,000 0,700 7,00 6,0,700,,00,900,000,00 8,700 7,0 6,0,900, ,,900 0,0 7,0 6,00,,0,00 0,0 7,900 7,900 7,60,0,700,0 7,00,00 9,900 8,0,00,700,0,00,70 0,000 9,00,00 0 8, 0,0 6,0,00,0,00,0 0, 9,000,700,0, 9,0,700,0,0,900,00 0,0 7,,0 9,00,0 7,,0 6,0 6,00 9,0,0 6,0 9,0,0 8,00,0,900,,900,000 7,00,900 7,00 ll Models With lue Holder 6,0,000,0,0,0,0, ,00,0,900,0,0,00, ,00 8,0 7,0 6,00,0,,700,0 0,0 0,00 8,0 6,0,0,0,700,0,0 0,0 9,0 8,0 7,0,00,0,0 9,,700,700 9,000 7,00,00,0,0,00,00 0,000 8,900 6,0,0,00 0 7,0,0 0,0 9,00 6,0,0,00 6,00,0,000,0 9,000,700,0,00, 8,900,700,0 7,700,000,000 0,900 7,,0 9,0 6,700, 7,,0 8,0 7,00,700 9,0,0 6,000 9,0,0 6,0,,900,,900,00 7,00,0 7,00 ll Models With lue Holder 0,0 6,0 6,00,0,000,0,0 0,700 9,00 7,00 6,00,0,0,0,0,0, 9,000 8,0 6,700,00,00,0 6,0,000 0,0 8,0 6,700,000,00,0 6,0,00,00 0,700 8,0,000,00 0 6,700,0,00 8,700 6,0,000,00 8,0,000,0,0 9,00,00,0 8,900,00 9,000,00,0 9,00 7,00,900,0 6,700,0 9,0,700,0 6,700,0 9,000,0 9,00,0 6,000 9,00,0 9,000,900,900,00 7,00,0 7,00 ll Models With lue Holder 0,000 8,0 6,0,000,000,0 0,700 8,700 7,0 6,00,000,700,0,000 9,0 8,0 6,0,0, 0,0 0, 8,0 6,700,000, 6,,0 9,700 7,700,00,0 7,700,000,0 9,0 7,0,00,0 7,0,000 0,000 6,0,0 9,0,700 9,00 6,0,0 7,0,0 9,,0 8,0,0 9,,0 7,0,700,900 7,0,700,900,00 7,00,0 7,00 ll Models With lue Holder,900 0,00 7,0,900,000,,0 0,900,000 8,900 7,00 6,000,,0,0,900,0 9,0 7,0,900,0 7,0,0 9,700 7,,900,0 7,900,0,000 0,000 6,0,0 9,00,00,000 9,00 6,0,0 8,0,0 9,,0 8,0 9,,0 9,00,700,900 7,0,700,900 7,00 7,00 For optimum performance, regulator should be operated above solid line. For UPSO Models, use only above dashed line. 0 ontact your merican Meter representative for inlet pressures above.

MKII SERVICE REGULATOR

MKII SERVICE REGULATOR ¾" / 1" J125 MKII Example illustrated is a J125S4 version with USS Over Pressure Slam Shut option. Inlet Pressures up to 8.6 Bar The MKII Jeavons J125 service regulator is fitted with an improved lever

More information

F200 Pilot Operated Pressure Regulator

F200 Pilot Operated Pressure Regulator F00 Pilot Operated Pressure Regulator External or Internal Pressure Registration Minimize Sudden ownstream Load Change Ideal for Fix Factor Billing Quick Response Time / High ccuracy The F00 series is

More information

CS800 Series Commercial/Industrial Pressure Reducing Regulators

CS800 Series Commercial/Industrial Pressure Reducing Regulators Bulletin 71.1 D103140X012 CS800 Series April 2018 CS800 Series Commercial/Industrial Pressure Reducing Regulators P1235 P1234 Type CS800 REGULATOR Type CS800IQ with High Capacity Relief P1521 P1692 TYPe

More information

2010B. Available Materials Aluminum Carbon Steel Stainless Steel Ductile Iron Special Materials on Application

2010B. Available Materials Aluminum Carbon Steel Stainless Steel Ductile Iron Special Materials on Application OVER EQUIPMENT VRE 0 / 00 Series PRESSURE N VUUM RELIEF VLVE The 0/00 protects tanks from damage or deformation, and minimizes emissions to the environment, as well as loss of product due to evaporation.

More information

P200 Pressure Regulator

P200 Pressure Regulator P200 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P202 has internal relief valve for overpressure protection The P200 series pressure regulator is a manual, direct acting,

More information

CP400 Series Commercial/Industrial Pressure Loaded Pressure Reducing Regulators

CP400 Series Commercial/Industrial Pressure Loaded Pressure Reducing Regulators CP400 Series Commercial/Industrial Pressure Loaded Pressure Reducing Regulators September 2014 P1182 typical type cp400 regulator P1522 P1410 Typical type CP403 Regulator WITH INTEGRAL TRUE-MONITOR PROTECTION

More information

P200 Pressure Regulator

P200 Pressure Regulator P200 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P202 has internal relief valve for overpressure protection The P200 series pressure regulator is a manual, direct acting,

More information

P200 Pressure Regulator

P200 Pressure Regulator P200 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P202 has internal relief valve for overpressure protection The P200 series pressure regulator is a manual, direct acting,

More information

T200 Pressure Regulator

T200 Pressure Regulator T200 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges T202 has internal relief valve for overpressure protection The T200 series pressure regulator is a manual, direct acting,

More information

Performance Literature for J125 Gas Pressure Regulators 1½ and 2 Sizes. Catalogue

Performance Literature for J125 Gas Pressure Regulators 1½ and 2 Sizes. Catalogue Catalogue and Performance Literature for J125 Gas Pressure Regulators 1½ and 2 Sizes Catalogue General Information Regulating Capacity Capacity Figures 1½ size Capacity Figures 2 size CS2503D DS2501B DS2502B

More information

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C

The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C ulletin 617 Rev. Model R ommercial Riser Riser Manifold for ommercial pplications ulletin 617 Rev. vailable Sizes/Pressure Ratings: 1 1 / 2 (40mm) and 2 (50mm) Threaded - 250 psi (17,2 bar) Working Pressure

More information

F300 Pressure Regulator

F300 Pressure Regulator F300 Pressure Regulator Minimize Sudden Downstream Load Change Wide Pressure Ranges P302 has Internal Relief Valve for Overpressure Protection Ideal for Fix Factor Billing The F300 series pilot operated

More information

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm)

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm) RP Series Regulators Introduction The RP Series regulators are direct-operated with non-balanced trim. Normally they are fitted with a built-in filter. They are produced in the following versions: Types

More information

Series 100 Slam Shut Valve

Series 100 Slam Shut Valve IMP 8775 Series 00 Slam Shut Valve Sizes ", ", 4" Installation & Maintenance Instructions Read carefully and follow all instructions shipped with this regulator. The incorrect installation of this equipment

More information

P600 Pressure Regulator

P600 Pressure Regulator P600 Pressure Regulator The BelGAS P600 series is a direct operated, pressure reducing regulator that can be used as a pressure loaded regulator, switching valve, or monitoring regulator. Available with

More information

Type FL Pressure Reducing Regulators

Type FL Pressure Reducing Regulators ulletin 71.2 D103067X012 Type FL January 2017 Type FL Pressure Reducing Regulators Features No tmospheric leed Eliminates nuisance and wasteful bleed gas to atmosphere by utilizing a self-contained control

More information

D I V I S I O N O F M A R S H B E L L O F R A M

D I V I S I O N O F M A R S H B E L L O F R A M PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil

More information

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications Bulletin 71.1 D103087X012 Type HSR December 2017 Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications High Capacity Compact Design P1524_1 High Capacity Internal

More information

P99 Pressure Reducing Regulator

P99 Pressure Reducing Regulator P99 Pressure Reducing Regulator Applications City / District gate operation Commercial buildings Boilers, furnace, oven Plant air service Features 5 Pilot choices for low to extra high pressure Up to 1,000

More information

SINGLE ACTING TELESCOPIC

SINGLE ACTING TELESCOPIC SINGLE TING TELESOPI RM is pleased to offer a full line of standard telescopic designs for your equipment. These designs are pre-engineered using in stock material and internal components for quick order

More information

T205 Series Tank Blanketing Regulators

T205 Series Tank Blanketing Regulators Bulletin 74.1 D103747X012 T205 Series June 2018 T205 Series Tank Blanketing Regulators Figure 1. Type T205 Tank Blanketing Regulator Contents Features... 1 Introduction.... 1 Specifications... 2 Principle

More information

P95H Regulator Applications P95H Part Matrix Specifi cations Materials of Construction P95H Flow Coeffi cients Wide Open Coeffi cients

P95H Regulator Applications P95H Part Matrix Specifi cations Materials of Construction P95H Flow Coeffi cients Wide Open Coeffi cients PH Regulator Large Capacity Working Media Include ir, Steam and Liquids ll Vents are Tapped The PH is a direct operating pressure reducing regulator with large capacity. Ideally suited for uses in oil

More information

Zurn Wilkins Fire Protection Series. Backflow Preventers, Pressure Regulating Valves, and Water Control Products for Fire Sprinkler Applications

Zurn Wilkins Fire Protection Series. Backflow Preventers, Pressure Regulating Valves, and Water Control Products for Fire Sprinkler Applications Zurn Wilkins ire Protection Series ackflow Preventers, Pressure Regulating Valves, and Water ontrol Products for ire Sprinkler pplications Zurn Wilkins ire Protection Series Zurn Wilkins fire protection

More information

T205 Series Tank Blanketing Regulators

T205 Series Tank Blanketing Regulators T205 Series Tank Blanketing Regulators Bulletin 74.1:T205 September 2013 Figure 1. Type T205 Tank Blanketing Regulator Contents Features...1 Introduction...2 Specifi cations...2 Principle of Operation...2

More information

BULLETIN SEPTEMBER 2009 BOS OFFSET DISC RESILIENT- SEATED BUTTERFLY VALVES TECHNICAL SPECIFICATIONS

BULLETIN SEPTEMBER 2009 BOS OFFSET DISC RESILIENT- SEATED BUTTERFLY VALVES TECHNICAL SPECIFICATIONS ULLETIN 46.00-2 SEPTEMER 2009 OS OFFSET IS RESILIENT- SETE UTTERFLY VLVES TEHNIL SPEIFITIONS Materials of onstruction 2 s (50-) 8 9 7 Wafer and Lugged esign 10 3 Wafer ody Lugged ody 6 5 4 1 2 2 s (50-)

More information

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 2520VQSV10* ***** ******* 20* M 2492 S. Released

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 2520VQSV10* ***** ******* 20* M 2492 S. Released Service ata Vickers Vane Pumps Vane Type Triple Pump (F3) 2520VQSV10* ***** ******* 20* Released 08 01 95 M 2492 S 10 SE rated capacity (V10 cover end cartridge) USgpm Rotor Vane Kit Ring Pin Pin olt olt

More information

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 4525VQSV10* ***** ******* 20* Released M 2496 S

Vickers. Service Data. Vane Pumps. Vane Type Triple Pump (F3) 4525VQSV10* ***** ******* 20* Released M 2496 S Service ata Vickers Vane Pumps Vane Type Triple Pump (F3) 4525VQSV10* ***** ******* 20* Released 08 01 95 M 2496 S 10 SE rated capacity (V10 cover end cartridge) USgpm Rotor Vane Kit Ring Pin Pin olt olt

More information

Aluminumcase Dry Test Meters DTM-200A and DTM-325 Repair Parts

Aluminumcase Dry Test Meters DTM-200A and DTM-325 Repair Parts A C E D RPL-7800. DTM-00A and DTM- Meters Aluminumcase Dry Test Meters DTM-00A and DTM- Repair Parts DTM-00A DTM- www.americanmeter.com AMC Quality System QMI is Accredited by: C R E D I T ISO 900 Certified

More information

4-Way, 5-Port, 2 & 3-Position Solenoid and Remote Pilot 1/2" & 3/4" Ports. Technical & Service Data. Pneumatic

4-Way, 5-Port, 2 & 3-Position Solenoid and Remote Pilot 1/2 & 3/4 Ports. Technical & Service Data. Pneumatic atalog VL-UTO-/US (Revised 6/0/0) pplication & Model Selection S utomotive Subbase Valves -Way, -ort, & -osition Solenoid and Remote ilot /" & /" orts pplication ual pressure or diverter valve operation

More information

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM FRM Medium Pressure Regulator Medium pressure regulator Type FRM Direct acting pressure regulator with adjustable setpoint springs and modular mounted safety shutoff valve (SAV) In compliance with EN 334

More information

Low Voltage Fuses AFaC and BaC types

Low Voltage Fuses AFaC and BaC types Fa and a types Fa and a type currentlimiting fuses 600V /, 3 400 mps escription The Fa and a type have an excellent current-limiting performance with an interrupting capacity as high as 100k at 600V /.

More information

F200 Pilot Operated Pressure Regulator

F200 Pilot Operated Pressure Regulator F200 Pilot Operated Pressure Regulator External or Internal Pressure Registration Minimize Sudden Downstream Load Change Ideal for Fix Factor Billing Quick Response Time / High ccuracy The F200 series

More information

cs200 series commercial / Industrial pressure reducing regulators

cs200 series commercial / Industrial pressure reducing regulators November 2013 cs200 series commercial / Industrial pressure reducing regulators P1188 Figure 1. Typical CS200 Series Pressure Reducing Regulator Features and Benefits Wide Range of Body Sizes and End Connections

More information

Agilent Aluminum Block Valves - Series 26 NW 16 - NW 40 ISO-KF Flange

Agilent Aluminum Block Valves - Series 26 NW 16 - NW 40 ISO-KF Flange gilent lock Valves - Series 26 - ISO-KF Flange ata sheet gilent Valves by Thank you for choosing gilent Valves by VT. With the combination of these two well-known names in the Vacuum industry, we are confident

More information

B-34 Series Regulator Parts List. Effective June 2002

B-34 Series Regulator Parts List. Effective June 2002 B-34 Series Regulator Parts List Effective June 2002 B-34N Reference Schematics B-34R Reference Schematics 2 Note: See Reference Schematics B-34 Series Service Regulators (Models N,R, M, D, IMN, IMR, IMRV,

More information

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM FRM Medium Pressure Regulator Medium pressure regulator Type FRM Direct acting pressure regulator with adjustable setpoint springs and modular mounted safety shutoff valve (SAV) In compliance with EN 334

More information

Cipriani Harrison Valves Corp.

Cipriani Harrison Valves Corp. pplication Sanitary ball valves are used in stainless steel piping systems for isolation, either manually or automatically operated. The full port design with zero flow restriction makes it an optimum

More information

1 Cylinder. 1 - Cylinder Type 3 - Cylinder Capacity 4 - Cylinder Stroke. 2 - Cylinder Options. Cylinder Accessories

1 Cylinder. 1 - Cylinder Type 3 - Cylinder Capacity 4 - Cylinder Stroke. 2 - Cylinder Options. Cylinder Accessories 1 Type 30 06 T 2 3 4 5 apacity Stroke Options ode 1 - Type 3 - apacity 4 - Stroke ydraulic 2 - Options L LN LN P P T U U U ULN S/ - ollow ole / - eneral Purpose / - ollow ole / - igh Tonnage S/ - lat ody

More information

VB2, VB3 Ball Valve/Actuator Assemblies

VB2, VB3 Ball Valve/Actuator Assemblies V2, V all Valve/ctuator ssemblies TURS PROUT T V2 V V2 ll Models Sizes from 1/2 in. to 2 in. with internal nominal pipe thread (NPT) connections. qual Percentage flow characteristics. ield configurable

More information

627 Series Pressure Reducing Regulators

627 Series Pressure Reducing Regulators 627 Series Pressure Reducing Regulators Introduction The 627 Series direct-operated reducing regulators (Figure 1) are for low and high systems. These regulators can be used with natural gas, air, or a

More information

197C. Valve Group. Series Farris Engineering Pressure Relief Valves

197C. Valve Group. Series Farris Engineering Pressure Relief Valves 97 Valve Group Series 700 Farris Engineering Pressure Relief Valves Numbering System Selecting and specifying Farris pressure relief valves is simple using the numbering system that follows. Each digit

More information

Safety Shut-off Valve SL/SID/RSL

Safety Shut-off Valve SL/SID/RSL Safety Shut-off Valve SL/SID/RSL High accuracy shut-off Low pressure loss Operating temperature up to -30 C Easy maintenance DVGW-approval Applications They are designed for transmission and distribution

More information

Winslow Lube Oil Full-Flow Type 1 Filter Service Instructions

Winslow Lube Oil Full-Flow Type 1 Filter Service Instructions Vent Plug (NPT) Winslow Lube Oil ull-low Type 1 ilter Service Instructions Parts List Part escription Part over ssembly and lamp Housing rain Plug ilter lement omponent Kit See Ordering Information on

More information

Single-Seat Valves For the Sanitary Industries

Single-Seat Valves For the Sanitary Industries www.swagelok.com Single-Seat s For the Sanitary Industries Stainless steel construction Shutoff, divert, modulating, and specialty valves 1/2 to 4 sizes Kwik-lamp and tube butt weld end connections 3-

More information

Piston Accumulators Series Catalog HY /US

Piston Accumulators Series Catalog HY /US Series 3000 Series 3000 Heavy uty Service with 3000 PSI Operating Pressure 2" thru 12" ores with Over 50 Standard apacities Patented V-O-ring Piston Seals Serviceable Threaded End onstruction Five Standard

More information

3/2 ^ % Features. Construction. Electrical

3/2 ^ % Features. Construction. Electrical 4 Pilot Operated Spool Valves xplosionproof Solenoid Valves 316L odies 1/4" NPT 3/2 SRIS 364 eatures Ideal for oil and gas control panel applications rop-in replacement design - compatible with most existing

More information

Feed Pumps FZP / MFZP

Feed Pumps FZP / MFZP eed Pumps ZP / MZP Symbol General The feed pump from the ZP series is a vane pump for the low-pressure range with constant flow rate. Product eatures l irect drive pump no bell housing or coupling required

More information

VG4000 Series. High-Capacity/High-Closeoff Electric Zone Valves

VG4000 Series. High-Capacity/High-Closeoff Electric Zone Valves Product ulletin VG000 Issue ate 11/01/01 VG000 Series High-apacity/High-loseoff Electric Zone Valves VG000 Series High-apacity/High-loseoff Electric Zone Valves are designed to regulate the flow of water

More information

Winslow Lube Oil By-Pass Type 1 Filter Service Instructions

Winslow Lube Oil By-Pass Type 1 Filter Service Instructions Vent Plug (NPT) Winslow Lube Oil y-pass Type 1 ilter Service Instructions Parts List Part escription Part over ssembly and lamp Housing rain Plug ilter lement omponent Kit See Ordering Information on Page

More information

ROTORK FAIRCHILD MODEL T7500 LOW PRESSURE TRANSDUCER Installation, Operation and Maintenance Instructions

ROTORK FAIRCHILD MODEL T7500 LOW PRESSURE TRANSDUCER Installation, Operation and Maintenance Instructions ROTORK FIRHIL MOEL T7500 LOW PRESSURE TRNSUER Installation, Operation and Maintenance Instructions Introduction The T7500 series low pressure transducer is a precision low pressure electropneumatic transducer

More information

From the Hyson family of higher force gas springs

From the Hyson family of higher force gas springs rom the Hyson family of higher force gas springs Same force and diameter as T3 Series S-4 (7/16-20) port for use with standard full size hoses ive sizes from 1000 to 9500 Up to 21,400 lbs. contact force

More information

Stainless Steel The Next Generation of Backflow

Stainless Steel The Next Generation of Backflow Stainless Steel The Next Generation of Backflow Zurn Wilkins Stainless Steel Backflow Preventer Superior Quality, Technologically dvanced 3L grade stainless steel body available in grooved or flanged end

More information

627 Series Pressure Reducing Regulators

627 Series Pressure Reducing Regulators 627 Series Pressure Reducing Regulators Introduction The 627 Series direct-operated pressure reducing regulators (Figure 1) are for low and high pressure systems. These regulators can be used with natural

More information

627 Series Pressure Reducing Regulators

627 Series Pressure Reducing Regulators 627 Series Pressure Reducing Regulators Introduction The 627 Series direct-operated pressure reducing regulators (Figure 1) are for low and high-pressure systems. These regulators can be used with natural

More information

SRB Series. UL Recognized CSA Certified VDE Approved* Specifications. SRB Series. Power Inlet Filters & Power Entry Modules

SRB Series. UL Recognized CSA Certified VDE Approved* Specifications. SRB Series. Power Inlet Filters & Power Entry Modules orcom Product Guide atalog: 161 Issue ate: 6.11 Minimum epth, ost-effective Shielded Power Inlet Filter SR Series UL Recognized S ertified V pproved* SRP SRS8 SR1 SR2 SR Series Smallest depth orcom RFI

More information

Now Available in Black Zinc Nickel

Now Available in Black Zinc Nickel 847/848 Series Power Supply up to 63 Now vailable in lack Zinc Nickel The 847/848 bayonet Series has been especially designed for light and harsh environment. Its physical characteristics and performances

More information

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications March 2013 Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications High Capacity Compact Design High Capacity Internal Relief TYPE HSR ANGLE BODY Globe Bodies Angle

More information

503 Series Solenoid Pilot Actuated Valves

503 Series Solenoid Pilot Actuated Valves Solenoid Pilot ctuated Valves Offered by: Specialists in Valves, ontrols, Pneumatics, Fluid Measurement Phone: (203) 261-6711 www.okcautomation.com 5 Ported, 2 and 3 position, 4-way, Spool & Sleeve and

More information

Bike Bollard R-7904 (RSA)

Bike Bollard R-7904 (RSA) ike ollard R-0 (RS) General escription: The R-0 ike ollard offers versatile design and functionality. ike-locking arms are bolted internally to applications. R-0 ike ollards are made from carbon steel

More information

Piston Accumulators Series Catalog HY /US Page

Piston Accumulators Series Catalog HY /US Page Page Series 5000 Series 5000 Piston ccumulators Heavy uty Service with 5000 PSI Operating Pressure 2" thru 9" ores with Over 30 Standard apacities Patented V-O-ring Piston Seals Serviceable Threaded End

More information

Solenoid Pilot Actuated Valves

Solenoid Pilot Actuated Valves Solenoid Pilot ctuated Valves 02 Series irectional ontrol Valve www.asco.com Table of ontents 02 Series Features and enefits Performance ata How to Order Sandwich Option Kit 9 Speed ontrol Kit 9 Shut

More information

Hydraulic Systems Hydraulic Clamping

Hydraulic Systems Hydraulic Clamping ydraulic Systems 19. 1 ydraulic lamping Page ydraulic lamping Page 1-21-4 1-21-51 1-21-72 1-211-2 1-211-4 1-211-52 1-211-54 1-212-4 19.2-19.3 3-1-S-475 3-1--475 19.6 52-Series 19.3 3-1-S-11 19.7 3-1--11

More information

Flat Fan Nozzles. Flat Fan nozzles can be used fo washing, rinsing and surface treatments including high pressure nozzles used at up to 200 bar.

Flat Fan Nozzles. Flat Fan nozzles can be used fo washing, rinsing and surface treatments including high pressure nozzles used at up to 200 bar. vailable in a wide range of spray angles and flows. Liquid is forced through an oval or eliptical orifice to form a sheet of spray that breaks into ligaments and then droplets or is atomised by impacting

More information

,, WY VLVS Way Valves - Side ntry Product index... p. - Way Valves - ottom ntry Product index... p. Way Valves - ottom ntry Product index...p. ontents

,, WY VLVS Way Valves - Side ntry Product index... p. - Way Valves - ottom ntry Product index... p. Way Valves - ottom ntry Product index...p. ontents MTRI,, WY VLVS 6P/6P SRIS ,, WY VLVS Way Valves - Side ntry Product index... p. - Way Valves - ottom ntry Product index... p. Way Valves - ottom ntry Product index...p. ontents Introduction... Page - Product

More information

SRG LPG Liquid Service/Offtake Valve Type /

SRG LPG Liquid Service/Offtake Valve Type / SRG LPG Liquid Service/Offtake Valve Type 480-426 / 480-427 Inlet Connection Outlet Connection Width across flats ¾ NPT 1 ¼ NPT M26x1,814 36 mm 46 mm Product Description: The SRG type 480 liquid service

More information

Section F Air Atomizing Spray Nozzles

Section F Air Atomizing Spray Nozzles Section F tomizing Overview If your application requires air atomizing nozzles, you ll find information on the largest selection in the industry available in this section. hoose from dozens of nozzle bodies,

More information

Model ZW204 Non-Modulating Float Valve

Model ZW204 Non-Modulating Float Valve Model Z04 Non-Modulating loat Valve pplication The Zurn ilkins Model Z04 Non-Modulating loat Operated ontrol Valve is designed to be either fully open or fully closed in response to the position of the

More information

Lab Specialty Products Technical Information TECHNICAL INFORMATION WEIGHTS & DIMENSIONS

Lab Specialty Products Technical Information TECHNICAL INFORMATION WEIGHTS & DIMENSIONS Lab Specialty Products Technical Information TECHNICL INFORMTION WEIGHTS & DIMENSIONS Contact Spears for any Information not found. Page 569 Lab Ball s Sample Engineering Specification ll thermoplastic

More information

R627 High Flow Gas Regulator with Internal Relief

R627 High Flow Gas Regulator with Internal Relief High Flow Gas Regulator with Internal Relief The Relieving Regulator has an internal relief valve that provides protection against over pressurization. As output pressure builds up above the start-to-discharge

More information

Y690A Series Pressure Reducing Regulators

Y690A Series Pressure Reducing Regulators Instruction Manual Form 5463 Y690A Series April 1999 Y690A Series Pressure Reducing Regulators Introduction Scope of Manual This manual provides instructions for installation, startup, maintenance, and

More information

Smith Meter Truck Meter Packages Specifications

Smith Meter Truck Meter Packages Specifications Issue/Rev. 0.4 (8/12) P Meter Smith Meter Truck Meter Packages Specifications ulletin SS01095 TP (Ticket Printer) LN (Large Numeral ounter) Preset ounter Air Eliminator/ Strainer Faucet P Meter Smith Meter

More information

Instrument Ball Valves

Instrument Ball Valves www.swagelok.com Instrument all s 40 Series On-off, switching, and crossover flow paths Working pressures up to 3000 psig (206 bar) Temperatures from 50 to 150 (10 to 65 ) Low-temperature service option

More information

KEY FEATURES. Product Overview. Product Line Drawing

KEY FEATURES. Product Overview. Product Line Drawing Main Valves Options Model 106-C 106-PG-C Globe KEY FETURES Solves high pressure drop problems Controls variable flows & vibration Significantly reduces noise Self-contained actuators not required Customizable

More information

GTS, GTX and E-CLASS GAS TURBINE METERS SB

GTS, GTX and E-CLASS GAS TURBINE METERS SB GTS, GTX and E-CLASS GAS TURINE METERS S 4510.4 An American Pioneer In Gas Measurement Accuracy, repeatability, rangeability and flow range make gas turbine meters the preferred choice in an increasing

More information

Piston Accumulators Series Catalog /USA Page

Piston Accumulators Series Catalog /USA Page atalog 1630-7/US Page Piston ccumulators Series 5000 Series 5000 Piston ccumulators Heavy uty Service with 5000 PSI Operating Pressure 2" thru 9" ores with Over 30 Standard apacities Patented V-O-ring

More information

Oil Management. Temprite Oil Reservoirs. Model Maximum Working Pressure: 44.8 bar (650 PSI) RES7 Oil Reservoir for CO 2

Oil Management. Temprite Oil Reservoirs. Model Maximum Working Pressure: 44.8 bar (650 PSI) RES7 Oil Reservoir for CO 2 Temprite Oil Reservoirs Model 47154 Maximum Working Pressure: 44.8 bar (650 PSI) 47154 Part # Model # Oil onn. apacity apacity E Sight Glasses 90040000 47154 3/8" SE 4 Gal. 512 oz. 15 Liters 3.5 Gal. 448

More information

Type. Facts. Flanged Safety Relief Valves spring loaded TMetric + US Units. The-Safety-Valve.com

Type. Facts. Flanged Safety Relief Valves spring loaded TMetric + US Units. The-Safety-Valve.com ype 26 Flanged Safety Relief Valves spring loaded Metric + US Units Facts he-safety-valve.com ype 26 Orifice Selection charts 1 x 1 3L x 1 3 x 1 6 x 1 9 x 1 x 1 2 x 3 WCB 262.67X See 3 x 1 262.676X WC6

More information

T3T Series. From the Hyson family of higher force gas springs. Dynamic Solutions for a Global Market. Same force and diameter as T3 Series

T3T Series. From the Hyson family of higher force gas springs. Dynamic Solutions for a Global Market. Same force and diameter as T3 Series T3T Series rom the Hyson family of higher force gas springs Same force and diameter as T3 Series S-4 (7/16-20) port for use with standard full size hoses Uses T2 flange mounts ive sizes from 1000 to 9500

More information

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. KIA Amanti TOOLS REQUIRED:

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. KIA Amanti TOOLS REQUIRED: INSTLLTION INSTRUTIONS FOR PRT 99-7 PPLITIONS KI manti 007-008 99-7 KIT FETURES DIN Radio Provision ISO Mount Radio Provision KIT OMPONENTS ) Radio Housing ) ISO rackets ) Trim Plate TOOLS REQUIRED: Small

More information

Fisher D and DA Control Valves

Fisher D and DA Control Valves D and D Valves Product Bulletin Fisher D and D Control Valves Fisher D and D single port, high pressure valves are widely used in oil and gas production industries. These valves are especially useful for

More information

KTM MODEL NB / MB THREE-WAY BALL VALVES 2-SEATS (L-PORT) AND 4-SEATS (L AND T-PORT)

KTM MODEL NB / MB THREE-WAY BALL VALVES 2-SEATS (L-PORT) AND 4-SEATS (L AND T-PORT) KTM MODEL N / M THREE-WY LL VLVES 2-SETS (L-PORT) ND 4-SETS (L ND T-PORT) single KTM 3-way ball valve replaces several 2-way valves, saving valuable space and simplifying piping FETURES Positive alignment

More information

Carter Pressure Loss Compensator and Venturis. Model Model Model Model Model 64086

Carter Pressure Loss Compensator and Venturis. Model Model Model Model Model 64086 Carter Pressure Loss Compensator and Venturis Model 60559 Model 64088 Model 64085 Model 64193 Model 64086 esign Concepts Eaton s Carter product line includes Model 60559 Pressure Loss Compensator and a

More information

DIRECTIONAL CONTROL (LD) DIRECTIONAL AND FLOW CONTROL (LD) SOLENOID OPERATED DIRECTIONAL

DIRECTIONAL CONTROL (LD) DIRECTIONAL AND FLOW CONTROL (LD) SOLENOID OPERATED DIRECTIONAL Pu. EC-01 DIRECTIONL CONTROL (LD) DIRECTIONL ND FLOW CONTROL (LD) SOLENOID OPERTED DIRECTIONL CONTROL (LDS) RELIEF (L) / SOLENOID CONTROLLED RELIEF (LS) VLVES Up to 31.5 MPa (4570 PSI), 5500 L / min (1453

More information

Powers TM Controls RL 243 SW Switching Relay

Powers TM Controls RL 243 SW Switching Relay Powers TM ontrols RL 243 W witching ocument No. 155-040P25 RL 243-4 escription The Powers 243 W witching is a two-position, pilot-operated auxiliary device used for switching a common part from one pneumatic

More information

Pressure Control Valves. General Description. Specifications. Ordering Information

Pressure Control Valves. General Description. Specifications. Ordering Information Catalog HY14-3000/US Technical Information Control Valves Series RCP General escription Series RCP in-line pressure control valves are chiefly used as remote control valves. They limit system pressure

More information

LX Hand Pump Oil. hand pumps - anti-sludge, anti-rust additives. HF oil - good low temperature performance. Dimensions (in) Model No. A-64 A-65 1.

LX Hand Pump Oil. hand pumps - anti-sludge, anti-rust additives. HF oil - good low temperature performance. Dimensions (in) Model No. A-64 A-65 1. Hydraulic Oil, Manifolds and Fittings Shown top to bottom: HF-, HF-, HF-2, LX-, 6, and FZ Enerpac System omponents HF Oil power pumps efficiency - prevents cavitation - anti-sludge, anti-rust, anti-foam

More information

Tension Brakes/Air Cooled

Tension Brakes/Air Cooled IST. UTORIZO Tension rakes/ir ooled MX (55) 53 63 23 31 Magnum rakes The Wichita Magnum rake sets new standards in performance, safety and serviceability. The Magnum is easy to apply and simple to service.

More information

TESTO ITC KORINNA 28mm Allargato LOAD SENSING MONOBLOCK DIRECTIONAL CONTROL VALVE

TESTO ITC KORINNA 28mm Allargato LOAD SENSING MONOBLOCK DIRECTIONAL CONTROL VALVE ESO IC KORINN 28mm llargato LOD SENSING MONOLOCK DIRECIONL CONROL VLVE Features Simple, compact and heavy duty designed 2 sections monoblock valve, for hydraulic systems with load sensing variable displacement

More information

Product Information / Order Code

Product Information / Order Code Product Information / Order ode Order odes eries and Type low onitoring ystem G - 0.04 - - 1 - V - X G Version 0,002... 2 l/min / 0.0005... 0.53 U GP 0.02 0,004... 4 l/min / 0.0011... 1.06 U GP 0.04 0,01...

More information

GCS GCS

GCS GCS ENGINEERING T PKGE GS / ELETRI GS16 024 030 036 048 060 GS20 036 048 060 2 to 5 Ton (7.0 to 17.3 ) FUE 80% SEER up to 12.70 Net apacity 23,200 to 59,000 tuh (6.8 to 17.3 ) Input Heating apacity 50,000

More information

GOVERNORS. Line Pressure Regulators Mod. Stab

GOVERNORS. Line Pressure Regulators Mod. Stab S Line Pressure Regulators Stab.300-310 Regulators Line Pressure Regulators Introduction Pietro Fiorentini self-operated pressure governors are designed and manufactured according to the latest international

More information

Toyota/Lexus A340E, A340F 00-LATER, V6 & V8 ZIP KIT

Toyota/Lexus A340E, A340F 00-LATER, V6 & V8 ZIP KIT Toyota/Lexus 40E, 40F 00-LTER, V6 & V8 ZIP KIT PRT NUMER 40-LTE-ZIP QUIK GUIDE NOTE: Type 4 EP-style valve body is shown. Parts will fit in the same locations in a throttle cable-style and Type EP-style

More information

Hand Crank & Brake Assembly. 12V 1 /3 hp Motor. See Page 128 for Reel Dimensions & Sizes. (lengths over 100' are spliced)

Hand Crank & Brake Assembly. 12V 1 /3 hp Motor. See Page 128 for Reel Dimensions & Sizes. (lengths over 100' are spliced) ooster The kron rass ooster Reel is designed to be light weight and extremely durable. There are more options than ever as these reels are available in multiple sizes, and in both electric and manual rewind.

More information

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S 16/26 SRIS O M P A T & S T A N A R M O U L A R A I R P R P A R A T I O N S Y S T M S WILKRSON FILTRS, RGULATORS AN LURIATORS R26 Regulator F26 Filter L26 Lubricator M16 oalescing Filter 6 Filter/Regulator

More information

Safety directional valves with spool position monitoring

Safety directional valves with spool position monitoring Table EY0100/E Safety directional valves with spool position monitoring Onoff, direct operated, conforming to Machine irective 2006/42/E certified by ody Spool Inductive proximity sensor FI Inductive position

More information

EEA & EEB Series. UL Recognized CSA Certified VDE Approved EEA2 / EEB2

EEA & EEB Series. UL Recognized CSA Certified VDE Approved EEA2 / EEB2 atalog: 16541 Issue ate: 6.11 Including the S/S and H/H Models ost-effective MI Power Inlet Filter UL Recognized S ertified V pproved 2 / 2 1 / 1 P / P Series ompact single stage MI filter with I 63-1

More information

OBSOLETE DOCUMENT. 95 Series Industrial Pressure Regulators. Bulletin 71.1:95.

OBSOLETE DOCUMENT. 95 Series Industrial Pressure Regulators. Bulletin 71.1:95. 95 Series Industrial Pressure Regulators W5091 / IL W1894-1 / IL TYPE 95LD TYPE 95L W6195 / IL Figure 1. 95 Series Pressure Reducing Regulators TYPE 95LD (FLNGED) www.emersonprocess.com/regulators ulletin

More information

Cord Connectors AMERICAN FITTINGS. Corporation. Specification Grade Alloy Steel, Aluminum, Stainless Made in the USA

Cord Connectors AMERICAN FITTINGS. Corporation. Specification Grade Alloy Steel, Aluminum, Stainless Made in the USA ord onnectors Specification Grade lloy Steel, luminum, Stainless Made in the US Why ren t Your ables Wearing the EST? STOP USING OUTTE OR ONNETORS N ONNET WITH THE EST! MFIO SPE-grade Strain Relief ord

More information

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN

MTD Silent Series MIXED FLOW IN-LINE DUCT FAN MT Silent Series MIX LOW IN-LIN UT N Mixed low In-Line uct an MT Silent Series MT Silent 100/2~200/2 MT Silent 250~315 Low profile Mixed-flow fans with sound- absorbent insulation. xtreme ly quiet. General

More information

PDE2611TCUK-ca Air Preparation. Miniature FRL series. Miniature FRL Series. Parker Hannifin Corporation Pneumatic Division - Europe

PDE2611TCUK-ca Air Preparation. Miniature FRL series. Miniature FRL Series. Parker Hannifin Corporation Pneumatic Division - Europe P26TUK-ca ir Preparation Miniature RL series Miniature RL Series 49 Parker Hannifin orporation Pneumatic ivision - urope P26TUK-ca ir Preparation Miniature RL series - /8", /4" asic /8" ody 4 ilters -

More information