Section F Air Atomizing Spray Nozzles

Size: px
Start display at page:

Download "Section F Air Atomizing Spray Nozzles"

Transcription

1 Section F tomizing Overview If your application requires air atomizing nozzles, you ll find information on the largest selection in the industry available in this section. hoose from dozens of nozzle bodies, assemblies and spray set-ups to get the precise performance you require. atomizing nozzles require a single air source for the atomizing air. Some versions, equipped with a cylinder for automatic operation or clean-out and shut-off needles, may require an additional air line. Fluid lines are required for all models. The fluid line can be pressurized or supplied using a siphon- or gravityfed configuration. It is recommended that air and fluid lines are equipped with the proper filters, regulators and valves. atomizing nozzles require spray set-ups. Each set-up consists of an air cap and fluid cap and some may also include O-rings and retainer caps. You can select from a wide assortment of capacities, spray patterns and pressure- or siphon-fed set-ups. Product Range: 1/J and 1/J Series nozzles are available in many configurations and operate at standard flow rates. Ranges from: 0. to.1 at psi (2.0 to 2 l/h at 2. bar). Variable spray nozzles provide independent control of liquid, atomizing air and fan air pressure for fine tuning of flow rate, drop size, spray distribution and coverage. 1/2J Series nozzles offer the same features and benefits as 1/J and 1/J Series but operate at higher capacities. Ranges from:.2 to 2 at psi ( to l/h at 2. bar). 1J Series nozzles offer the highest flow rates available. Ranges from: 1 to 0 at psi ( to l/h at 2. bar). dditional information can be found in Section G, utomatic and in Section K, Special Purpose. tomizing Table of ontents asic Information s F Features... F 1/J and 1/J Series Overview/Nozzle odies/nozzle ssemblies F Pressure s, Internal Mix F Pressure s, External Mix... F1 Pressure s, Internal Mix, High Transfer Efficiency (HTE)... F1 Siphon/Gravity-Fed s, External Mix... F2 1/JJ ompact Series Overview F2 Nozzle odies/nozzle ssemblies F2 Pressure s, Internal Mix F2 Pressure s, External Mix, High apacity F1 Pressure s, Internal Mix, Efficient F Siphon/Gravity-Fed s, External Mix... F Variable Series Variable... F Pressure s, External Mix... F 1/2J Series Nozzle odies/nozzle ssemblies F Pressure s, Internal Mix F Pressure s, External Mix... F Siphon/Gravity-Fed s, External Mix... F tomizing atomizing caps 1J Series Nozzle odies/nozzle ssemblies F0 Pressure s, Internal Mix F1 Pressure s, External Mix... F Siphon/Gravity-Fed s, External Mix... F Special Purpose Jet Fogger... F ripsafe Jet Fogger... F Humidification and Units F Humidification System omponents F tomizing ccessories... F1 Phone spray, FX 1---spray F1

2 tomizing tomizing Optimization Tips Reduce installation time by using split-eyelet connectors on both the air and fluid lines. Split-eyelet connectors only require a hole drilled into the pipe, eliminating the need for cutting, threading and brazing operations. To eliminate the unintentional release of non-atomized liquid, use a check valve to shut down liquid flow if no air pressure is detected. Use air atomizing nozzles with clean-out needles to eliminate clogging and ensure optimum performance. Use strainers and air filters to ensure optimum performance. If positive shut-off is required, use rip Free set-ups with JU nozzles. Use a heat jacket with VU/VMU variable spray nozzles to keep viscous liquids warm and transferable. When adjusting air pressure with internal mix nozzles, do not exceed recommended values as it may result in choking liquid flow. Increasing liquid flow can also choke air flow. For optimal control of your air atomizing spray system, the use of an utojet System helps conserve liquid usage and reduces scrap by monitoring and automatically adjusting spray pattern, flow rate, drop size, liquid pressure and atomizing air pressure. utojet ontrollers and Systems atomizing nozzles with clean-out needles Heat jackets nozzles Hot fluid flow channel ut out view of heat jacket showing unique flow channel Phone spray, FX 1---spray F2

3 s, asic Information Liquid can be supplied to the nozzle under pressure or it can be supplied through a liquid siphon or gravity-feed. Pressure s Siphon/Gravity-Fed s Liquid is supplied to the nozzle under pressure. and liquid can be externally or internally mixed to produce a completely atomized spray. 1/J and 1/J Series Pages F F1 1/2J Series Pages F F 1J Series Pages F0 F2 ompact 1/JJ Series Pages F2 F Variable 1/V Series Pages F F2 New High Transfer Efficiency (HTE) external mix air atomizing set-ups recently introduced for 1/J Series. Pages F1 F Liquid is supplied via liquid siphon or is gravity-fed. esigned to draw liquid through the feed line into the air flow where it is atomized. 1/J and 1/J Series Pages F2 F ompact 1/JJ Series Pages F F 1/2J Series Page 1J Series Page tomizing 1/JN air atomizing nozzle pressure regulator with gauge shut-off valve filter inlet Liquid inlet Liquid shut-off valve pressure regulator with gauge 1/JN air atomizing nozzle Siphon tube Siphon height shut-off valve filter inlet Liquid pressure regulator with gauge TW liquid strainer Liquid container Phone spray, FX 1---spray F

4 Features, asic Information tomizing Features Each series is available with a pressure spray set-up or siphon spray set-up. Each set-up provides a specific spray pattern with a specific capacity and spray coverage range performance. set-ups are interchangeable for each nozzle series. Round spray: Extended full cone round spray pattern. Wide angle round spray: Hollow cone-type, wide angle round spray pattern. circular spray: Hollow cone-type circular spray pattern. Flat spray: Extended flat or sheet-type spray pattern. eflected flat spray: Extended flat or sheet-type spray diverted away from the axis of the inlet connection. Each spray set-up consists of an air cap and fluid cap. For more information request ata Sheets 1 and 1-1. tomization ontrol Features chieved by adjusting the air and liquid pressure in the spray set-up. Obtaining finer atomization is accomplished by increasing the air pressure and/or lowering the liquid pressure, resulting in a high ratio of air flow rate to liquid flow rate. External mix with pressure set-ups: Flat and round spray patterns. cap Fluid cap Internal Mix Features Liquid and air are mixed internally to produce a completely atomized spray. Liquid and gas streams are not independent and a change in air flow will affect the liquid flow. Internal mix uses pressure set-ups and is available with the following spray patterns: circular spray. eflected flat spray. Elliptical spray. Flat spray. Round spray. Wide angle round spray. External Mix Features Liquid and air streams are mixed outside of the nozzle. and liquid flow can be controlled independently. Effective for higher viscosity liquids and abrasive suspensions. External mix can use siphon set-ups or pressure set-ups. When a siphon set-up is used, a round spray pattern is produced. When a pressure set-up is used, a flat spray pattern is produced. Internal mix with pressure set-ups: Round spray patterns Internal mix with pressure set-ups: Flat spray patterns External mix with siphon set-ups: Round spray patterns External mix with pressure set-ups: Flat spray patterns Phone spray, FX 1---spray F

5 Overview/Nozzle odies/nozzle ssemblies, 1/J and 1/J Series 1/J and 1/J Series air atomizing 1/J, 1/J set-up for HTE Plug P 1/JN, 1/JN 1 2 set-up Shut-off needle assembly 1/JO, 1/JO 10 1/J, 10 1/J Retainer ring P 2. cap. Fluid cap. Fluid cap gasket P. Nozzle body P1. ack seal gasket P set-up for rip Free lean-out needle assembly 2 Shut-off/clean-out needle assembly 1 tomizing 1/JU rip Free 1 2 Shut-off/clean-out needle assembly Features and enefits The basic J Series nozzle assembly consists of a body and a spray set-up. Various assemblies can be added to provide shut-off and clean-out functions. 1/J and 1/J bodies have liquid and air feeds at opposite ends of the body. odies are provided with a removable plug so other needle assemblies may be added in the future. JN features a manual shut-off needle that enables the flow of liquid to the nozzle to be stopped. JO features a clean-out needle that is activated manually. The needle slides through the liquid orifice to clear obstructions. Ideal for intermittent spraying applications when liquid can dry in the orifice between uses. 10 combines the features of JN and JO offering a combination shut-off/clean-out needle. Phone spray, FX 1---spray F

6 Nozzle odies/nozzle ssemblies, 1/J and 1/J Series tomizing 1/J, 1/J 1/" and 1/" NPT or SPT Optimization Tips See page F2 for optimization tips. 1/JN, 1/JN 1/" and 1/" NPT or SPT with shut-off needle 1/JO, 1/JO 1/" or 1/" NPT or SPT with clean-out needle See lso ccessories line filters pressure regulators Liquid pressure regulators 10-1/J, 1/J 1/" or 1/" NPT or SPT with shut-off/clean-out needle Pressure gauges Solenoid valves Strainers s Ordering Info Nozzle odies Electroless Nickelplated rass ode Nozzle Type J JN JO 10 (none) l l l l Stainless Steel SS l l l l Lucite * LU l s Lucite* LU l Electroless Nickelplated rass ap and Stainless Steel SSR l l l l Stainless Steel SS l l l l *May not be available for all spray set-ups listed. Other materials available upon request. omplete Nozzle ssembly Nozzle ody* *Includes retainer and gasket. 1/ JN SS SUF SS l l l l l Inlet onn. Nozzle ody ssembly Type ode ode SPT connections require the addition of a prior to the nozzle body inlet connection. To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: 0-SS. To order air cap only, use air cap number (shown in performance data charts) and material code: -SS. To order spray nozzle without set-up, use inlet connection, nozzle body and material code: 1/JN-SS. Only SUF l To order spray set-up only, use spray set-up number and material code: SUF-SS. SS l ode Phone spray, FX 1---spray F

7 Nozzle odies/nozzle ssemblies, 1/J and 1/J Series Features and enefits 1/JF features a built-in liquid strainer. 1/JFN features built-in liquid strainer and liquid shut-off needle. J features the center lines of the air and liquid inlet entering in the back of the nozzle and parallel to the spray projection axis. J features air and liquid inlet connections entering the nozzle at 0 to spray projection axis. JN features air and liquid inlet connections entering the nozzle at 0 to spray projection axis and a shut-off needle. 1/-2J dual spray assembly features two opposing spray set-ups with the air and liquid inlet connections perpendicular to the spray axis. The multiple swivel spray assembly features each spray set-up mounted on its own swivel body. One or two bodies may be used and each can be rotated to the desired position. Swivel bodies are locked in place by a stainless steel lock screw that runs vertical through the assembly. 2-1/J miniature assembly body is only 1/2" ( mm) thick with a 1-/2" (2 mm) by 1-1/" (2 mm) rectangular face. The tip of the nozzle projects from the face a maximum of 1-/1" ( mm) depending upon the spray set-up used. 1/JJ features a steam jacket around the nozzle body for spraying liquids that are too viscous to spray at room temperature. With Strainer ack onnect Top Inlet Top Inlet 1/JF and 1/JFN 1/" NPT or SPT (F) air inlet connection 1/" NPT or SPT (F) liquid inlet connection 1/J and 1/J 1/" or 1/" NPT or SPT (F) inlet connection 1/J, 1/JN 1/J, 1/JN 1/" or 1/" NPT or SPT (F) inlet connection 1/-2J 1/" NPT or SPT (F) inlet connection tomizing Swivel Miniature Optimization Tips See page F2 for optimization tips. See lso 1/" NPT or SPT (F) air and liquid inlet connection Steam Jacket 1/JJ 1/" NPT or SPT (F) inlet/outlet connection 2-1/J 1/" NPT or SPT (F) air and liquid inlet connection ccessories line filters pressure regulators Liquid pressure regulators Strainers For J, request ata Sheets, and 1 For J and JN, request ata Sheets and -1 For 1/-2J dual spray assembly, request ata Sheet For multiple swivel spray assembly, request ata Sheet For 2-1/J, request ata Sheet 2 Pressure gauges Solenoid valves For 1/JJ, request ata Sheets and 1 Phone spray, FX 1---spray F

8 Nozzle odies/nozzle ssemblies, 1/J and 1/J Series tomizing Features and enefits multiple spray assembly (cluster type) features five spray set-ups located on the faces of the assembly or four set-ups located on the side faces. 2J is a dual spray assembly with opposing spray set-ups perpendicular to opposing air and liquid inlets. Thin wall adapters add an adapter locknut and gasket to P thick wall adapters to provide secure mounting in thin walls and include P locknut and P20- gasket. Thick wall adapters replace retainer rings on nozzle assemblies and fit into threaded wall openings, holding the nozzle securely in place. 1/JLN and 1/JLO feature a screw mount with /2" ( mm) diameter mounting holes. Standard 1/" ( mm) screws hold the body to the wall with a gasket providing the seal. The 1/JLN features a shut-off needle and the 1/JLO features a clean-out needle. 0 Series hand-held air atomizing spray guns feature lightweight aluminum construction and a comfortable, easy-to-operate design. Extensions are available in up to " (1 cm) lengths. luster Type Twin Thin Walls Thick Walls 1/" NPT or SPT (F) air and liquid inlet connection 2J 1/" NPT or SPT (F) inlet connection vailable for 1/J and 1/J assemblies 1/J and 1/J with /" NPT or SPT (M) adapter connection Screw Mount Optimization Tips See page F2 for optimization tips. 1/" NPT or SPT (F) air and liquid inlet connection 0 Hand-held spray gun 1/" NPT or SPT (F) inlet connection See lso ccessories line filters pressure regulators Pressure gauges Solenoid valves Liquid pressure regulators Strainers For multiple spray assembly, request ata Sheet For 2J, request ata Sheets and For thin wall adapters, request ata Sheet For thick wall adapters, request ata Sheets, 00 and 2 For 1/JLN and 1/JLO, request ata Sheet 0 For 0 Series hand-held air atomizing spray guns, request ata Sheets 0J, 0JN, 0JMO, 0JN-1, 0JJ, 0JJN and 0JJNTK Phone spray, FX 1---spray F

9 Pressure s, Internal Mix, 1/J and 1/J Series s Round spray air caps produce a narrow, full cone round spray pattern Features and enefits For round spray pattern, angle is maintained throughout distance. eyond, the spray becomes turbulent and will project out to distance. When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. cap Fluid cap Round spray pattern Performance ata retainer ring and gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. retainer ring gasket tomizing Round SU 0 Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure dd F to part number for rip Free set-ups. Example: SUF. * 2 Liquid* imensions ngle ( ) 1 1-1/2 1-1/2 (ft.) -1/2-1/2 Phone spray, FX 1---spray F

10 Pressure s, Internal Mix, 1/J and 1/J Series tomizing Performance ata Round SU 0 1 Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * 2 Liquid* imensions ngle ( ) (ft.) 1 1 SU / /2 SU SU SU dd F to part number for rip Free set-ups. Example: SUF. Phone spray, FX 1---spray F

11 Pressure s, Internal Mix, 1/J and 1/J Series s Features and enefits Wide angle round spray and circular spray air caps produce hollow cone, wide angle round spray and circular spray patterns. Performance ata Wide ngle Round SU1 SU2 SU For wide angle round spray, dimensions, and are the pattern widths at distances from the nozzle. The total distance of spray projection from the nozzle to the maximum dispersal point is represented by. When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. Wide angle round spray pattern retainer ring and gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. " (1 cm) " (2 cm) 1" ( cm) cap Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure dd F to part number for rip Free set-ups. Example: SUF. retainer ring * 2 Fluid cap Liquid* gasket imensions -1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2 (ft.) -1/2-1/2-1/2-1/2-1/2-1/2 1-1/2-1/2-1/2-1/2-1/2-1/2-1/ /2 1-1/2-1/2 tomizing Phone spray, FX 1---spray F

12 Pressure s, Internal Mix, 1/J and 1/J Series tomizing Performance ata Wide ngle Round SU Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * Liquid* imensions -1/2-1/2-1/2-1/2-1/2-1/2-1/2 1 1 (ft.) 1 2 SU /2-1/2-1/2-1/2-1/2-1/2-1/2-1/ SU /2-1/2-1/2-1/ / / dd F to part number for rip Free set-ups. Example: SUF. ircular SU H Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure dd F to part number for rip Free set-ups. Example: SUF. circular spray pattern Phone spray, FX 1---spray F

13 Pressure s, Internal Mix, 1/J and 1/J Series s Flat spray and deflected flat spray air caps produce flat or deflected flat spray patterns. Features and enefits For flat spray pattern, dimensions, and are the pattern widths at distances from the nozzle. The total distance of spray projection from the nozzle to the maximum dispersal point is represented by. When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. cap Fluid cap Performance ata Flat SU SU SUN Flat spray pattern " (1 cm) " (2 cm) 1" ( cm) retainer ring and gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure dd F to part number for rip Free set-ups. Example: SUF. retainer ring * Liquid* imensions 1 1-1/ gasket (ft.) -1/2-1/2-1/2-1/2 1 tomizing Phone spray, FX 1---spray F

14 Pressure s, Internal Mix, 1/J and 1/J Series tomizing Performance ata Flat SU SUN2 SU2 SU2 SU Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure dd F to part number for rip Free set-ups. Example: SUF. * Liquid* imensions (ft.) -1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2 1 1 eflected Flat SU2E Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure dd F to part number for rip Free set-ups. Example: SUF. eflected flat spray pattern Phone spray, FX 1---spray F

15 Pressure s, External Mix, 1/J and 1/J Series s External mix air caps produce a flat spray pattern. Features and enefits tomization can be controlled by varying the air pressure without changing liquid flow rates with external mix set-ups. For flat spray, dimensions, and are the pattern widths at distances from the nozzle. The total distance of spray projection from the nozzle to the maximum dispersal point is represented by. When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. The liquid and compressed air or gas are mixed externally to produce a completely atomized spray. cap Fluid cap Performance ata Flat spray pattern " (1 cm) " (2 cm) 1" ( cm) retainer ring gasket retainer ring and gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. tomizing Flat (External Mix) Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * Liquid* imensions (ft.) SUE /2-1/2-1/2-1/2-1/2-1/2 dd F to part number for rip Free set-ups. Example: SUF. Phone spray, FX 1---spray F1

16 Pressure s, External Mix, 1/J and 1/J Series tomizing Performance ata Flat (External Mix) SUE1 1 - Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * 1 1 Liquid* imensions 1-1/ /2 (ft.) -1/2-1/ /2-1/2-1/2 SUE /2-1/2-1/ /2 SUE / / / /2 SUE /2-1/2-1/2-1/2-1/2-1/ /2 SUE / /2 dd F to part number for rip Free set-ups. Example: SUF. Phone spray, FX 1---spray F1

17 Pressure s, External Mix, 1/J and 1/J Series Performance ata Flat (External Mix) Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * Liquid* imensions (ft.) /2-1/ /2 SUE /2-1/2-1/2-1/ /2-1/ /2-1/2-1/2 1 SUE / tomizing /2-1/ /2-1/2 SUE /2-1/2-1/2-1/2-1/ /2-1/ SUE2 SUE /2-1/ dd F to part number for rip Free set-ups. Example: SUF. Phone spray, FX 1---spray F1

18 Pressure s, External Mix, 1/J and 1/J Series tomizing Performance ata Flat (External Mix) SUE Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * Liquid* imensions -1/2-1/2-1/2-1/2-1/2-1/2 1-1/ /2 1 (ft.) -1/2 1-1/2 SUE /2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/ /2 1 SUE /2-1/2-1/2-1/ / SUE /2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/ dd F to part number for rip Free set-ups. Example: SUF. Phone spray, FX 1---spray F1

19 Pressure s, External Mix, High Transfer Efficiency (HTE), 1/J Series Features and enefits new air cap design enables the use of lower air pressures to achieve the same spray performance as conventional external mix set-ups. Flat spray pattern HTE set-ups operate at pressures as low as psi (0. bar). large air chamber directly feeds the air exit orifices. esign provides high liquid transfer efficiency, minimal air loss, and minimal misting. consumption is reduced and maximum spray coverage on the target is achieved. See also Section G, utomatic s Round spray pattern " (1 cm) " (2 cm) 1" ( cm) " (1 cm) " (2 cm) 1" ( cm) retainer ring and gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. HTE air cap produces a flat spray and a round spray. Performance ata tomizing Flat (External Mix) SU-HTE SU-HTEE SU-HTEF PF20 LP2- PF0 LP2- PF1 LP2- Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure dd F to part number for rip Free set-ups. Example: SU-HTE-F. The operating pressures and flow rates are based on spraying water and air at room temperature. djustments may need to be made to accommodate other liquids with different characteristics. * Liquid* imensions -1/2-1/2-1/2-1/2-1/2-1/2-1/2 1-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/ Phone spray, FX 1---spray F1

20 Pressure s, External Mix, High Transfer Efficiency (HTE), 1/J Series tomizing Performance ata Flat (External Mix) SU-HTE1 SU-HTE1 SU-HTE1E SU-HTE1F SU-HTE2 SU-HTE2E PF LP- PF20 LP- PF0 LP- PF1 LP- PF20 LP2-0 PF0 LP2-0 Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure dd F to part number for rip Free set-ups. Example: SU-HTE-F. The operating pressures and flow rates are based on spraying water and air at room temperature. djustments may need to be made to accommodate other liquids with different characteristics. * Liquid* imensions -1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2 1-1/2-1/2-1/2-1/2-1/2 1-1/2-1/2-1/2-1/2-1/2-1/2-1/2 1-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2 1-1/2-1/2 1-1/2-1/ /2-1/2-1/2 1-1/2-1/2-1/ Phone spray, FX 1---spray F

21 Pressure s, External Mix, High Transfer Efficiency (HTE), 1/J Series Performance ata Flat (External Mix) Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure 1 * Liquid* imensions SU-HTE2F PF1 LP /2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/ SU-HTE SU-HTE PF LP1- PF20 LP / tomizing SU-HTEE PF0 LP /2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/ SU-HTEF PF1 LP /2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/ dd F to part number for rip Free set-ups. Example: SU-HTE-F. The operating pressures and flow rates are based on spraying water and air at room temperature. djustments may need to be made to accommodate other liquids with different characteristics. Phone spray, FX 1---spray F

22 Pressure s, External Mix, High Transfer Efficiency (HTE), 1/J Series tomizing Performance ata Round (External Mix) SU-HTE1 SU-HTE1 SU-HTE1 PF20 LP- PF0 LP- PF1 LP- Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure dd F to part number for rip Free set-ups. Example: SU-HTE-F. The operating pressures and flow rates are based on spraying water and air at room temperature. djustments may need to be made to accommodate other liquids with different characteristics. * Liquid* imensions 1-1/ /2 1-1/ / / /2 2-1/2-1/2-1/2-1/2 2-1/2 2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/ Ordering Info Nozzle ody* omplete Nozzle ssembly 1/ J SS SU-HTE SS l l l l l Inlet onn. Nozzle ode Number ode Only HTE SS l l Number ode SPT connections require the addition of a prior to the nozzle body inlet connection. *To order fluid cap only, use fluid cap number (shown in performance data charts and material code). To order air cap only, use air cap number (shown in performance data charts and material code). To order spray nozzle without set-up, use inlet connection, nozzle body and material code. To order rip Free set-ups, add F after set-up number: SU-HTE-F SS. Phone spray, FX 1---spray F

23 Siphon/Gravity-Fed s, External Mix, 1/J and 1/J Series s Round spray and flat spray air caps produce round spray and flat spray patterns. Features and enefits For round and flat sprays, angle is maintained throughout distance. eyond, the spray becomes turbulent and will project out to distance. When using a siphon or gravity-fed liquid system, the liquid is supplied by either a liquid siphon or a gravity-feed. esigned to draw liquid through the feed line into the air flow where it is atomized. Round spray pattern retainer ring and gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Refer to page F for Siphon/Gravity-Fed s diagram. Performance ata Flat tomizing tomizing apacity Gravity Head Liquid apacity (gallons per hour)* Siphon Height 1 * imensions at " Siphon Height (ft.) SUF /2-1/2-1/ SUF /2-1/2-1/2-1/2-1/2 1-1/ /2 1 1 SUF /2-1/2-1/2-1/2 SUF /2-1/2-1/2-1/2-1/2 Phone spray, FX 1---spray F2

24 Siphon/Gravity-Fed s, External Mix, 1/J and 1/J Series tomizing Performance ata Round SU1 SU1 1 0 tomizing apacity Gravity Head Liquid apacity (gallons per hour)* Siphon Height * imensions at " Siphon Height ngle ( ) (ft.) -1/2-1/2-1/2-1/2-1/2 SU SU SU SU Phone spray, FX 1---spray F

25 Overview, 1/JJ ompact Series 1/JJ Series air atomizing set-up 1/JJ 1 2 set-up 1/JJO lean-out needle assembly 1 1/JJN Retainer ring P2 2. cap. Fluid cap. O-ring 1-2/00. Nozzle body P1. Nozzle body P. ack Seal Gasket 2-U Shut-off needle assembly for rip Free 1/JJU rip Free Shut-off/clean-out needle assembly tomizing pplying lubricant to form presses in steel drum manufacturing. Phone spray, FX 1---spray F2

26 Nozzle odies/nozzle ssemblies, 1/JJ ompact Series tomizing Features and enefits Nozzle assembly consists of a body and spray set-up. Various assemblies can be added to provide shut-off or clean-out functions. 1/JJ has liquid and air feeds at opposite ends of the body. 1/JJN features a manual shut-off needle that enables the flow of liquid to be stopped. 1/JJO features a clean-out needle that is activated manually. Needle slides through the liquid orifice to clear obstructions. Ideal for intermittent spraying applications when liquid can dry in the orifice between uses. Optimization Tips See page F2 for optimization tips. See lso ccessories line filters pressure regulators Liquid pressure regulators Pressure gauges Solenoid valves Strainers 1/JJ 1/JJN 1/JJO 1/" NPT or SPT 1/" NPT or SPT with 1/" NPT or SPT with shut-off needle clean-out needle s Ordering Info Nozzle odies Electroless Nickelplated rass ode Nozzle Type JJ JJN JJO (none) l l l Stainless Steel SS l l l s Electroless Nickelplated rass ap and Stainless Steel SSR l l l Stainless Steel SS l l l omplete Nozzle ssembly Nozzle ody* 1/ JJN SS SUJ SS l l l l l Inlet onn. Nozzle ody ssembly Type ode *Includes retainer and gasket. ode SPT connections require the addition of a prior to the nozzle body inlet connection. To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: J0-SS. To order air cap only, use air cap number (shown in performance data charts) and material code: J1-SS. To order spray nozzle without set-up, use inlet connection, nozzle body and material code: 1/JJN-SS. Only SUJ SS l l ode To order spray set-up only, use spray set-up number and material code: SU-SS. Phone spray, FX 1---spray F2

27 Pressure s, Internal Mix, 1/JJ ompact Series s Features and enefits For round spray pattern, angle is maintained throughout distance. eyond, the spray becomes turbulent and will project out to distance. When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. Round spray and circular spray air caps produce full cone round spray; air caps used in spray set-up SUJ produce circular spray pattern. Round spray pattern 2 retainer ring and 1-2/00 O-ring must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Performance ata Round Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * Liquid* imensions ngle ( ) (ft.) tomizing SUJ J0 J /2 1-1/2-1/2-1/2 SUJ J0 J Phone spray, FX 1---spray F2

28 Pressure s, Internal Mix, 1/JJ ompact Series tomizing Performance ata Round SUJ J20 J1 Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * 2 Liquid* imensions ngle ( ) /2 (ft.) /2 SUJ J0 J SUJ J0 J ircular SUJ J0 J H Use only with 1/JJU automatic air atomizing nozzles. Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure circular spray pattern Phone spray, FX 1---spray F2

29 Pressure s, Internal Mix, 1/JJ ompact Series s Wide angle round and flat spray air caps produce hollow cone type, wide angle round spray and flat spray patterns. Features and enefits For wide angle round and flat sprays, dimensions, and are the pattern widths at distances from the nozzle. The total distance of spray projection from the nozzle to the maximum dispersal point is represented by. When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. Wide angle round spray pattern 2 retainer ring and 1-2/00 O-ring must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. " (1 cm) " (2 cm) 1" ( cm) Performance ata Wide ngle Round SUJ1 SUJ2 SUJ2 SUJ2 SUJ J0 J---0 J0 J1---0 J0 J1---0 J0 J J0 J1--- Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * Liquid* imensions -1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/ /2-1/2-1/ /2-1/2 (ft.) -1/2-1/2 1-1/2-1/2-1/2 1-1/2-1/ tomizing Phone spray, FX 1---spray F2

30 Pressure s, Internal Mix, 1/JJ ompact Series tomizing Performance ata Flat SUJ J0 J2 Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * 1 0 Liquid* imensions 1 1-1/ (ft.) -1/2-1/2 SUJ J20 J /2-1/2 SUJ J20 J /2-1/2-1/2 SUJ2 J0 J /2-1/2 SUJ2 J0 J /2-1/2-1/2 Phone spray, FX 1---spray F

31 Pressure s, External Mix, High apacity, 1/JJ ompact Series Features and enefits Offers an increased ability to atomize viscous fluids and allows for greater capacities of finely atomized sprays. Simple, one-piece, low-profile design permits larger air passage. More air can be brought in to atomize the liquid stream. tomization can be controlled by varying the air pressure without changing liquid flow rates. When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. s External mix air caps produce a flat spray pattern. Performance ata Flat (External Mix) SUJE1-0 SUJE1-0 SUJE1-0 SUJE-0 SUJE-0 PFJ1 PJ-0 PFJ0 PJ-0 PFJ20 PJ-0 PFJ0 PJ-0 PFJ0 PJ-0 Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure Flat spray pattern The liquid and compressed air or gas are mixed externally to produce a completely atomized spray. SUJE Series is both compact and air efficient. Offered in three spray angles 0, and 0. SUJE Series features lower spray velocity for improved transfer and reduced misting and is ideal for applications where space is limited. Very efficient use of air results in reduced air consumption costs and noise levels. Simple four-part assembly allows easy installation and maintenance. " (1 cm) " (2 cm) 1" ( cm) P2 retainer ring and P1-2/00-VI O-ring must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. The adapter is used with all 1/JJ nozzle bodies and automatic spray guns with extensions, but not on 1/JJU spray guns without extensions. Please contact your sales engineer. ngle 0 tomizing Phone spray, FX 1---spray F1

32 Pressure s, External Mix, High apacity, 1/JJ ompact Series tomizing Performance ata Flat (External Mix) SUJE1- SUJE1- SUJE1- SUJE- SUJE- SUJE1-0 SUJE1-0 SUJE1-0 SUJE-0 SUJE-0 PFJ1 PJ00- PFJ0 PJ00- PFJ20 PJ00- PFJ0 PJ- PFJ0 PJ- PFJ1 PJ0-0 PFJ0 PJ0-0 PFJ20 PJ0-0 PFJ0 PJ-0 PFJ0 PJ-0 Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure ngle 0 Phone spray, FX 1---spray F2

33 Pressure s, Internal Mix, Efficient, 1/JJ ompact Series s Elliptical spray pattern Internal mix air caps produce an elliptical spray pattern. Performance ata Elliptical / Efficient (Internal Mix) SUJ0 SUJ1 PFJ2 PJ PFJ PJ2-0 Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure imensions 1 2 * Liquid* ngle ( ) tomizing Tabulation is based on spraying air and water at room temperature under laboratory conditions. Phone spray, FX 1---spray F

34 Siphon/Gravity-Fed s, External Mix, 1/JJ ompact Series tomizing s Round spray air caps produce a full cone round spray pattern. Features and enefits For round spray pattern, angle is maintained throughout distance. eyond, the spray becomes turbulent and will project out to distance. When using a siphon or gravity-fed liquid system, the liquid is supplied by either a liquid siphon or a gravity-feed. esigned to draw liquid through the feed line into the air flow where it is atomized. Round spray pattern 2 retainer ring and 1-2/00 O-ring must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Performance ata Round SUJ1 SUJ1 SUJ2 SUJ2 SUJ SUJ SUJ J1 J J0 J J0 J0 J20 J0 J20 J- J0 J1 J0 J1 tomizing apacity Gravity Head Liquid apacity (gallons per hour)* Siphon Height SUJ SUJ SUJ SUJ SUJ SUJ SUJ * imensions at " Siphon Height ngle ( ) (ft.) -1/2-1/2-1/2-1/2-1/ Phone spray, FX 1---spray F

35 Siphon/Gravity-Fed s, External Mix, 1/JJ ompact Series s Features and enefits For flat spray pattern, dimensions, and are the pattern widths at distances from the nozzle. Total distance of spray projection from the nozzle to the maximum dispersal point is represented by. Flat spray air caps produce a flat spray pattern. Flat spray pattern " (1 cm) " (2 cm) 1" ( cm) Performance ata Flat tomizing apacity Gravity Head Liquid apacity (gallons per hour)* Siphon Height 1 * imensions at " Siphon Height (ft.) tomizing SUJF1 J20 J /2-1/2-1/ SUJF2 J J /2-1/2-1/2-1/2-1/2 1-1/ /2 1 1 SUJF J0 J /2-1/2-1/2-1/2 SUJF J0 J /2-1/2-1/2-1/2-1/2 Phone spray, FX 1---spray F

36 Overview/Nozzle odies/nozzle ssemblies, VU and VMU Series tomizing 1/V 1/VN 1/VO Variable Series air atomizing nozzles set-up 1 2 Plug -001-SS Shut-off needle assembly SS lean-out needle assembly 1/VNO 1. ap ring 2-1-SS 2. cap. Fluid cap. Nozzle body SS. Washer U Shut-off/clean-out needle assembly 1/VU Features and enefits The V, VU and VMU variable spray nozzles provide uniform spray distribution, even when spraying viscous liquids. Independent control of liquid, atomizing air, and fan air pressures is possible for fine-tuning of flow rate, drop size, spray distribution and coverage. an be set and re-set in seconds, simplifying application changes. Independent air atomizing line can be adjusted to vary spray drop size without affecting liquid flow rates. dditional inlet/outlet port allows for liquid recirculation that effectively maintains the flow of viscous liquids. V offers continuous operation and consists of a body, spray set-up and plug. VN features a manual shut-off needle that enables the flow of the liquid to be stopped. VO features a clean-out needle that clears the liquid orifice of obstructions when activated manually. VNO combines the features of the VN and VO, offering a combination shut-off/clean-out needle. VU offers automatic operation with a built-in shut-off/clean-out needle. VUPM has the same operating features as the VU, but offers the convenience of a mounting plate. VMU allows for individual adjustment of the atomizing air, fan air and liquid flows and offers modular components to accommodate a wide range of spray applications. Mounting Kit SS uses clamps to mount V nozzles. Mounting Kit -002-SS uses rods to mount V nozzles. Optimization Tips See page F2 for optimization tips. See lso ccessories line filters pressure regulators Liquid pressure regulators Pressure gauges Solenoid valves Strainers Phone spray, FX 1---spray F

37 Nozzle odies/nozzle ssemblies, VU and VMU Series VMU V VN VO 1/" NPT or SPT with shut-off/clean-out needle VNO 1/" NPT or SPT 1/" NPT or SPT with 1/" NPT or SPT with shut-off needle clean-out needle Mounting Kits VU 1/" NPT or SPT with shut-off/clean-out needle VUPM lamp mounting kits s Rod mounting kits 1/" NPT or SPT tomizing 1/" NPT or SPT ode Nozzle Type VMU V VN VO VNO VU VUPM Stainless Steel SS l l l l l l Stainless Steel/luminum SS l 1 Stainless Steel l /s Stainless Steel SS l l l l l l Other materials available upon request. Ordering Info omplete Nozzle ssembly Nozzle ody* 1/ V SS SUV SS l l l l l Inlet onn. Nozzle ody ssembly Type ode ode *Includes retainer and gasket. SPT connections require the addition of a prior to the nozzle body inlet connection. To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: VF1-SS. To order air cap only, use air cap number (shown in performance data charts) and material code: V2--SS. To order spray nozzle without set-up, use inlet connection, nozzle body, and material code: 1/V-SS. Order mounting kits separately: SS. Only SUV SS l l ode To order spray set-up only, use spray set-up number and material code: SUV-SS. Phone spray, FX 1---spray F

38 Pressure s, External Mix, VMU Series tomizing Performance ata VMU SUVM SUVM VMF1 VM2- VMF0 VM acity* apacity tomizing Fan Liquid apacity* ap tom..0.0 Water overage at Indicated istance from Nozzle Fan Pressure Phone spray, FX 1---spray F

39 Pressure s, External Mix, VMU Series Performance ata VMU acity* apacity tomizing Fan Liquid apacity* ap. tom. Water overage at Indicated istance from Nozzle Fan Pressure 0 SUVM SUVM1 VMF20 VM2- VMF VM tomizing SUVM1 VMF VM Phone spray, FX 1---spray F

40 Pressure s, External Mix, VMU Series tomizing Performance ata VMU SUVM SUVM VMF0 VM- VMF0 VM acity* apacity tomizing Fan Liquid apacity* ap tom..0.0 Water overage at Indicated istance from Nozzle Fan Pressure Phone spray, FX 1---spray F

41 Pressure s, External Mix, VU Series s Features and enefits Fan air tomized liquid Fan air External mix with fan air: flat spray pattern Without fan air: round spray pattern. Performance ata The dimensions, and of the flat spray pattern are controlled by the combination of fan air pressure and atomizing air pressure. The liquid flow rate is constant and not affected by the air pressure. Flat spray pattern " (1 cm) " (2 cm) 1" ( cm) 2-1-SS cap ring and U must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. VU SUV SUV SUV VF1 V2- VF0 V2- VF20 V acity* tomizing Fan Liquid apacity* ap tom overage (inches) at Indicated istance from Nozzle Since the pressures of the air and liquid lines are independently controlled, any combination of these air and liquid pressures can be used. The total air capacity is the sum of the atomizing air and the fan air. For instance, for atomizing air at psi and fan air at psi, the total is equal to.. for a total of.. t 0 psi fan air pressure the spray forms a round spray pattern. Request ata Sheets M-V, M-V and M-V. set-ups are interchangeable, but each set-up uses a different needle size. Water Fan Pressure tomizing Phone spray, FX 1---spray F1

42 Pressure s, External Mix, VU Series tomizing Performance ata VU SUV1 SUV1 SUV SUV VF V- VF V- VF0 V2- VF0 V acity* tomizing Fan Liquid apacity* ap tom Water overage (inches) at Indicated istance from Nozzle Fan Pressure Since the pressures of the air and liquid lines are independently controlled, any combination of these air and liquid pressures can be used. The total air capacity is the sum of the atomizing air and the fan air. For instance, for atomizing air at psi and fan air at psi, the total is equal to.. for a total of.. t 0 psi fan air pressure the spray forms a round spray pattern. Request ata Sheets M-V1, M-V1, M-V and M-V. set-ups are interchangeable, but each set-up uses a different needle size. Phone spray, FX 1---spray F2

43 Nozzle odies/nozzle ssemblies, 1/2J Series 1/2J 1/2J Series air atomizing nozzles 1/2J Plug P10 set-up 1/2JN 1/2" NPT or SPT 1/2JN 1/2JO Retainer ring P10 2. cap. Fluid cap. Fluid cap gasket P1. Nozzle body P101 Shut-off needle assembly lean-out needle assembly 2 1/2" NPT or SPT with shut-off needle 1/2JO 1/2" NPT or SPT with clean-out needle Features and enefits 1/2J air atomizing series ranges in capacity from.1 to (1. to l/h). The nozzles are available with shut-off and clean-out needles. 1/2J body has liquid and air feeds at opposite ends of the body and is provided with a removable plug so other needle assemblies may be added in the future. 1/2JN features a manual shut-off needle that enables the flow of liquid to be stopped. 1/2JO features a clean-out needle that is activated manually. The needle slides through the liquid orifice to clear obstructions. Ideal for intermittent spraying applications when liquid can dry in the orifice between uses. tomizing Optimization Tips See page F2 for optimization tips. See lso ccessories line filters pressure regulators Liquid pressure regulators Pressure gauges Solenoid valves Strainers s Ordering Info Nozzle odies ode Nozzle Type J JN JO Nickel-plated rass (none) l l l Stainless Steel SS l l l s Nickel-plated rass and Stainless Steel SSR l l l Stainless Steel SS l l l omplete Nozzle ssembly Nozzle ody* 1/2 JN SS SU SS l l l l l Inlet onn. Nozzle ody ssembly Type ode ode *Includes retainer and gasket. SPT connections require the addition of a prior to the nozzle body inlet connection. To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: 20-SS. To order air cap only, use air cap number (shown in performance data charts) and material code: Only SU SS l l ode To order spray set-up only, use spray set-up and material code: SU-SS. Phone spray, FX 1---spray F

44 Nozzle odies/nozzle ssemblies, 1/2J Series tomizing Features and enefits J features the center lines of the air and liquid inlet entering in the back of the nozzle and parallel to the spray projection axis. 1/2JJ features a steam jacket around the nozzle body for spraying liquids that are too viscous to spray at room temperature. 2J is a dual spray assembly with opposing spray set-ups perpendicular to opposing air and liquid inlets. Thick wall adapters replace retainer rings on nozzle assemblies and fit into threaded wall openings holding the nozzle securely in place. Optimization Tips See page F2 for optimization tips. See lso ccessories line filters pressure regulators Pressure gauges Solenoid valves Liquid pressure regulators Strainers For J, request ata Sheets, and 1 For 1/2JJ, request ata Sheets and 1 For 2J, request ata Sheets and For thick wall adapters, request ata Sheets, 00 and 2 ack onnect Steam Jacket Twin Thick Walls 1/2" NPT or SPT (F) inlet connection /" NPT or SPT (F) steam inlet/outlet connection 1/2" NPT or SPT (F) air and liquid inlet connection 1/2" NPT or SPT (F) inlet connection Please refer to data sheets 1/2J air atomizing nozzle 1/2J air atomizing nozzle used to spray seasoned cooking oil onto corn snacks. Phone spray, FX 1---spray F

45 Pressure s, Internal Mix, 1/2J Series s Features and enefits For wide angle round, round, circular and flat sprays, dimensions, and are the pattern widths at distances from the nozzle. The total distance of spray projection from the nozzle to the maximum dispersal point is represented by. When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. Wide angle round, round, flat and circular spray air caps produce wide angle round hollow cone spray, round hollow cone spray, flat spray and circular spray patterns. Performance ata 1 gasket must be ordered separately from the spray set-up, but is included in the standard nozzle assembly. Please contact your sales engineer. " (2 cm) 1" ( cm) 2" ( cm) cap Fluid cap 10 retainer ring 1 gasket tomizing Flat SU SU Pattern Flat Flat Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * 2 Liquid* imensions (ft.) Phone spray, FX 1---spray F

46 Pressure s, Internal Mix, 1/2J Series tomizing Performance ata Wide ngle Round and Round SU SU SU SU SU2 SU Pattern Wide ngle Round Wide ngle Round Wide ngle Round Wide ngle Round Round Round Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * Liquid* imensions -1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/2-1/ /2 1-1/ / / /2 1-1/2 1-1/ /2-1/2-1/2-1/2 2-1/2 2-1/ /2 2-1/2 2-1/2 2-1/ / (ft.) Phone spray, FX 1---spray F

47 Pressure s, External Mix, 1/2J Series s Flat spray air caps produce a flat spray pattern. Features and enefits The dimensions, and are the pattern widths at distances from the nozzle. The total distance of spray projection from the nozzle to the maximum dispersal point is represented by. SUE and SU0 are pressure set-ups using pressurized liquids. In SU0, the air and liquid mix internally, while in SUE, they mix externally. SU0 is a siphon set-up with the air and siphoned liquid mixing externally. cap Fluid cap Flat spray pattern Performance ata " (2 cm) 1" ( cm) 2" ( cm) 10 retainer ring 1 gasket 10 retainer ring and 1 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. tomizing Flat (External Mix) SUE 20 Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure * Liquid* 1 imensions -1/2-1/2-1/2 1-1/2-1/2 1-1/ /2-1/2 2 2 (ft.) Phone spray, FX 1---spray F

48 Pressure s, External Mix, 1/2J Series tomizing Performance ata ircular SU H Liquid apacity (gallons per hour)* and acity (standard cubic feet per minute)* Liquid Pressure circular spray pattern Odor control at a compost facility using air atomizing nozzles. Phone spray, FX 1---spray F

49 Siphon/Gravity-Fed s, External Mix, 1/2J Series s cap Fluid cap Round spray siphon air caps produce a round spray pattern. Round spray pattern " (2 cm) 1" ( cm) 2" ( cm) 10 retainer ring 10 retainer ring and 1 gasket must be ordered separately from the spray set-up, but are included in the standard nozzle assembly. Please contact your sales engineer. Refer to page F for Siphon/Gravity-Fed Liquid s diagram. 1 gasket Performance ata Round Siphon s SU0 20 tomizing apacity Gravity Head Liquid apacity (gallons per hour)* Siphon Height * imensions at " Siphon Height -1/2-1/2-1/2-1/2-1/2-1/2-1/2 (ft.) tomizing Phone spray, FX 1---spray F

50 Nozzle odies/nozzle ssemblies, 1J Series tomizing 1J 1JN 1J Series air atomizing set-up Retainer ring P 2. cap. Fluid cap. Nozzle body P Plug P10 Shut-off needle assembly 1J 1JN Features and enefits 1" NPT or SPT (F) 1" NPT or SPT (F) with shut-off needle Range in capacity from to 1 (1 to l/h). vailable with a shut-off needle. 1J features liquid and air feeds at opposite ends of the body and are provided with a removable plug so other needle assemblies may be added in the future. 1JN features a manual shut-off needle that enables the flow of liquid to be stopped. Optimization Tips See lso See page F2 for optimization tips. s ccessories line filters pressure regulators Liquid pressure regulators Ordering Info Pressure gauges Solenoid valves Strainers Nozzle odies ode Nozzle Type Nickel-plated rass (none) l l Stainless Steel SS l l s Nickel-plated rass and Stainless Steel J JN SSR l l Stainless Steel SS l l omplete Nozzle ssembly Nozzle ody* *Includes retainer and gasket. 1 JN SS SU1 SS l l l l l Inlet onn. Nozzle ody ssembly Type ode ode SPT connections require the addition of a prior to the nozzle body inlet connection. To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: 00-SS. To order air cap only, use air cap number (shown in performance data charts) and material code: SS. To order spray nozzle without set-up, use inlet connection, nozzle body and material code: 1JN-SS. Only SU1 l SS l ode To order spray set-up only, use spray set-up number and material code: SU1-SS. Phone spray, FX 1---spray F0

51 Pressure s, Internal Mix, 1J Series s Wide angle round, round, and flat spray air caps produce hollow cone, wide angle round spray, round and flat spray patterns. Features and enefits For wide angle round, round and flat sprays, dimensions, and are the pattern widths at distances from the nozzle. The total distance of spray projection from the nozzle to the maximum dispersal point is represented by. When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. The liquid and compressed air or gas are mixed internally to produce a completely atomized spray. cap Fluid cap Performance ata " ( cm) " ( cm) " (2 cm) retainer ring must be ordered separately from the spray set-up, but is included in the standard nozzle assembly. Please contact your sales engineer. retainer ring tomizing Wide ngle Round SU Pattern Wide ngle Round Liquid apacity (gallons per minute)* and acity (standard cubic feet per minute)* Liquid Pressure gpm gpm gpm gpm gpm * Liquid* imensions (ft.) Phone spray, FX 1---spray F1

52 Pressure s, Internal Mix, 1J Series tomizing Performance ata Round and Flat SU SU12 SU Pattern Round Round Flat Liquid apacity (gallons per minute)* and acity (standard cubic feet per minute)* Liquid Pressure gpm gpm gpm gpm gpm * Liquid* imensions (ft.) Phone spray, FX 1---spray F2

53 Pressure and Siphon/Gravity-Fed s, External Mix, 1J Series s Flat spray and round spray air caps produce a flat spray pattern and the siphon air caps produce a round spray pattern. Features and enefits For flat spray, dimensions, and are the pattern widths at distances from the nozzle. The total distance of spray projection from the nozzle to the maximum dispersal point is represented by. When using a pressure-fed liquid system, the liquid is supplied to the nozzle under pressure. The liquid and compressed air or gas are mixed externally to produce a completely atomized spray. For round spray, dimensions, and are the pattern widths at distances from the nozzle. The total distance of spray projection from the nozzle to the maximum dispersal point is represented by. When using a siphon or gravity-fed liquid system, the liquid is supplied by either a liquid siphon or a gravity-feed. esigned to draw liquid through the feed line into the air flow where it is atomized. cap Fluid cap Performance ata Flat spray pattern " ( cm) " ( cm) " (2 cm) 1 retainer ring 1 retainer ring must be ordered separately from the spray set-up, but is included in the standard nozzle assembly. Please contact your sales engineer. tomizing Flat (External Mix) SUE1 20 Pattern Flat Liquid apacity (gallons per minute)* and acity (standard cubic feet per minute)* Liquid Pressure 1 gpm Siphon s Round SU gpm gpm gpm tomizing apacity Refer to page F for Siphon/Gravity-Fed Liquid s. Gravity Head Liquid apacity (gallons per minute)* gpm Siphon Height imensions Phone spray, FX 1---spray F * 0 0 * 0 0 Liquid* 1 2 imensions at " Siphon Height (ft.) (ft.) 2

54 Fogger, Special Purpose tomizing 1/" NPT or SPT (F) threaded type QJ2 Split-eyelet type to clamp on 1/2", /", 1" pipe size Features and enefits produces high quality, cost-efficient dry fog. rops average fifteen microns in size and less. rop size is adjustable to meet specific industrial needs by changing the ratio of compressed air to water. Maintenance time is reduced because the built-in check valve, spray tip, and internal strainer are quickly serviced without tools. an use PV pipe and low-pressure air tubing. Tip has a relatively large clog-reducing orifice. QJ2 provides fast installation of the nozzle onto the liquid supply pipe no additional pipe fittings are required. Pipe cutting, threading and brazing are eliminated. Features a chemical-resistant, tight-fitting una-n seal to ensure leak-free performance. Ordering Info Specifications omplete Nozzle ssembly 1/ l l l Nozzle ody Inlet onn. Fluid Orifice ia. omplete Nozzle ssembly QJ2 / l l l Nozzle ody Pipe Size Fluid Orifice ia. SPT connections require the addition of a prior to the nozzle body inlet connection. Nozzle Inlet Jet Fogger Type 1/ To lamp On Pipe Size 1/2 Jet Fogger Type Fluid Orifice Orifice ia. Nom Fluid Orifice Orifice ia. Nom / QJ Humidification to reduce static charge in paint manufacturing plants. Phone spray, FX 1---spray F

55 Fogger, Special Purpose Performance ata, QJ2 Water Pressure Fluid Orifice 1 (.01" ia.) Pressure* , QJ2 Water Pressure Fluid Orifice (.0" ia.) Pressure* tomizing, QJ2 Water Pressure Fluid Orifice 2 (.02" ia.) Pressure* For applications with liquid pressures below psi (2 bar), request end cap sub-assembly 0--NY. In each line, figures in plain face indicate water atomized in (l/h) at psi (bar) water pressure. Figures in boldface indicate atomizing air in (Nl/min) at psi (bar) air pressure. Jet Fogger has a horizontal throwing distance of 1' (. m) and will expand to approximately ' (2. m) wide/' (. m) thick. 1. Values in blue area show optimum evaporation under normal room conditions, when center line of spray is ' (1. m) from the lower surface. 2. Values in red area can require up to ' ( m) for evaporation. Other values may be used where extended heat, higher air velocity exist or where slight surface wetting is permitted. Phone spray, FX 1---spray F

56 ripsafe Special Purpose Fogger, tomizing Features and enefits High-volume/high-efficiency air atomization. Produces an adjustable, high-quality dry fog without wetting with pressure-fed liquid. Ideal for large/open structures and areas with high air exchange rates. Operation is through a drip safe air-actuated liquid shut-off valve. utomatically prevents liquid from spraying until air pressure at the nozzle is sufficient for fine atomization. rip safe valve simplifies system construction and control while improving performance. Operates using normal water pressures found in municipal water systems, eliminating the need for expensive, high-pressure hydraulic pumps. requirements are met using an air compressor with a capacity range that is suitable for the application. Requires minimal maintenance. The flat spray tip has a large orifice that reduces clogging. set-up and built-in strainer are quickly removed by hand if cleaning is required. tip is brass; valve and body polymer. Operates at pressures up to 0 psi ( bar) with a minimum air pressure range of 2 to psi (1. to 2. bar). split-eyelet or saddle clamp version of the Jet Fogger (2 Series) is also available for quick and easy mounting to the liquid supply pipe. 2 2 Optimization Tips See page F2 for optimization tips. pplications 1/" NPT or SPT (F) Split-eyelet type to clamp on pipe 1/2" to 1" Evaporative cooling Fogging Humidification Insecticide spraying Plant propagation Specifications Nozzle Inlet onn. Jet Fogger Type 1/ 2 Fluid Orifice Orifice ia. Nom See lso ccessories line filters pressure regulators Liquid pressure regulators Pressure gauges Solenoid valves Strainers For and QJ2, request ata Sheets and 2 For 2 and 2, request ata Sheets and To lamp On Pipe Size 1/2 Jet Fogger Type Fluid Orifice Orifice ia. Nom / Phone spray, FX 1---spray F

57 ripsafe Special Purpose Fogger, Performance ata 2, 2 Water Pressure Fluid Orifice 1 (.01" ia.) Pressure* , 2 Water Pressure Fluid Orifice (.0" ia.) Pressure* , 2 Water Pressure Fluid Orifice 2 (.02" ia.) Pressure* In each line, figures in plain face indicate water atomized in (l/h) at psi (bar) water pressure. Figures in boldface indicate atomizing air in (Nl/min) at psi (bar) air pressure. 1. Values in blue area show optimum evaporation under normal room conditions, when center line of spray is ' (1. m) from the lower surface. 2. Values in red area can require up to ' ( m) for evaporation. Other values may be used where extended heat, higher air velocity exist or where slight surface wetting is permitted.. Jet Fogger has a horizontal throwing distance of 1' (. m) and will expand to approximately ' (2. m) wide/' (. m) thick. tomizing Ordering Info omplete Nozzle ssembly 2 1/ 1 l l l Nozzle ody Inlet onn. Fluid Orifice ia. omplete Nozzle ssembly 2 1/2 1 l l l Nozzle ody Pipe Size Fluid Orifice ia. SPT connections require the addition of a prior to the nozzle body inlet connection. Phone spray, FX 1---spray F

58 Humidification and Units tomizing Features and enefits ll equipment supplied for humidification systems except piping and wiring. 1/JH siphon air atomizing nozzles provide automatic, efficient humidity control with low installation and operating costs. operate either with compressed air drawing water from the float box by siphon action, or with water being delivered to the nozzle under pressure. Produces a fine atomized spray for rapid evaporation and efficient humidification. For information on siphon set-ups, see pages F2 to F. 1/JT pressure-fed air atomizing nozzles provide automatic, efficient humidity control with low installation and operating costs. Suitable for use in systems where water is under pressure. Have built-in strainers for air and water plus a ball check valve in the water line. Produces a fine atomized spray for rapid evaporation and efficient humidification. For information on pressure set-ups, see pages F to F. 0 humidification unit is a self-contained humidifier suitable for use with deionized water (I). Easy to install on a wall or for use in non-ducted applications. regulator and gauge, V air control solenoid and air line filter are included within the Humidification Unit. Wall-mounting bracket is also provided.. lbs. (. kg). For each spray set-up, water capacity ranges from 2. lbs./hr at psi (0. bar) air to. lbs./hr at psi ( bar) air. YMF MiniFogger III is ideal for humidification applications with limited space due to its compact design. vailable with a choice of one to four stainless steel spray nozzle set-ups with a wide variety of flow-rate sizes/droplet sizes and types. For each spray set-up, water capacity is 0.2 to 1.1 (1.0 to. l/h), and air capacity is to nl/min at. psi (.0 bar). an be placed in hard-to-reach spaces and can be easily installed on a header, on a wall or on a ceiling. 0. lbs. (2 g) for single spray set-up type; 0. lbs. (20 g) for multiple four set-up types. Height is." ( mm). The body, retainer cap, and tank are made of corrosionresistant polypropylene with stainless steel air and water connections. s are also compatible with deionized water. -00 provides a finely atomized spray without the use of compressed air. Produces a hollow cone spray pattern. Requires a minimum liquid pressure of psi (1 bar) to the nozzle. Maximum operating pressure of 00 psi ( bar). 1/JH 0 YMF -00 Siphon inlet connection 1/" NPT and SPT inlets 1/JT 1/" NPT or SPT (F) MiniFogger III 1/" NPT or SPT (F) air and liquid inlet connection 1/" NPT or SPT (F) misting nozzle Pressure-fed inlet connection 1/" NPT and SPT inlets Phone spray, FX 1---spray F

59 Humidification and Units Optimization Tips s See page F2 for optimization tips. See lso ccessories line filters pressure regulators Performance ata YMF MiniFogger III 0 psi Orifice iameter tomizing apacity Water apacity ata per Nozzle ( Pressure 0. MPa) Liquid apacity apacity Mean roplet Size (micron)* Pressure psi istance (ft.) SU2.N *Sauter Mean iameter 0.1 MPa = 1 bar Pressure gauges Solenoid valves Liquid pressure regulators Strainers For 1/JH siphon air atomizing nozzles, request ata Sheet 1 For 1/JT pressure-fed air atomizing nozzles, request ata Sheet For 0 humidification unit, request ata Sheet 0 For YMF MiniFogger III, request ata Sheet YMF -00 Liquid apacity Float box with float valve TW liquid strainer atomizing nozzle pipe assembly E Pipe hanger F filter G Pressure regulator with gauge H Solenoid valve I Switching relay J Humidistat Nozzle odies ode Nozzle Type JH JT 0 YMF rass (none) l Nickel-plated rass (none) l l Kynar KY l Stainless Steel SS l l /s Nickel-plated rass SSR l l Nickel-plated rass and Stainless Steel SSR l l Kynar KY l Stainless Steel SS l l l PTFE TEF l Ordering Info omplete Nozzle ssembly Nozzle ody* 1/ JH SS SU1 SS l l l l l Inlet onn. Nozzle ody ode *Includes retainer and gasket. ode SPT connections require the addition of a prior to the nozzle body inlet connection. To order spray set-up only, use spray set-up number and material code: SU1-SS. To order fluid cap only, use fluid cap number (shown in performance data charts) and material code: 1-SS. To order air cap only, use air cap number (shown in performance data charts) and material code: -SS. To order spray nozzle without set-up, use inlet connection, nozzle body and material code: 1/JH-SS. Humidification Unit YMF- l l Humidification Unit Type of s Humidification Unit 0 1 l l Humidification Unit Type Typical humidifying set-ups for siphon nozzles G F I H E J of s tomizing Phone spray, FX 1---spray F

60 Humidification System omponents tomizing Features and enefits 2-SE pipe assembly consists of straight and formed tubing with fittings, globe valve and split-eyelet connectors. Not assembled. - humidistat will respond to humidity levels in the range of % to % RH. Maximum operating temperature F (2 ). V ; 1V. Overall height " (1 cm). - switching relay has built-in transformer that supplies low-voltage current for humidistat circuit. 2-wire V control, V. Maximum temperature F ( ). 0 electric humidistat quick relative humidity L readouts from 1% to % with repeatability of ±%. Operating temperature range 2 F to 1 F (0 to 1 ). V ( or ). float valve used in 0 float box to shut off inlet flow at a preset water level. Made of S plastic, Stainless Steel, polypropylene with fiber washers and a brass nut. Optimization Tips See page F2 for optimization tips. 0 valve package is easy to install and use simply connect to existing air and fluid lines. The NEM type panel is completely sealed to eliminate moisture damage to components. Safety feature ensures there is no product damage due to unintentional water release. Stainless steel components available for use with deionized water. Separate atomizing and cylinder air lines with adjustable delay time assures liquid atomization. pipe hanger for proper spacing between air and liquid lines. Sizes fit 1/2" piping. Hanger is held by threaded rod and nuts (not included) for vertical adjustment. Made of cast aluminum. " ( cm) spacing. Use with 2-SE spray pipe assembly. See lso ccessories line filters pressure regulators Liquid pressure regulators Section L, ccessories Pressure gauges Solenoid valves Strainers For 2-SE pipe assembly, request ata Sheet 2-SE For 0 electrical humidistat, request ata Sheet SE pipe assembly Humidistat Switching relay Electric humidistat 0 0 Float valve Float box Valve package Pipe hanger Phone spray, FX 1---spray F

61 tomizing ccessories Features and enefits 1 pressure tank assembly meets SME oiler and Pressure Vessel ode requirements and OSH safety regulations. onstructed of Stainless Steel. ssembly includes a pressure regulator with gauge, SME coded pressure relief valve, air bleed valve and plug valves for air inlet and liquid outlet. Tanks are available in 1, 2, and gallon (.,., 1. and liter) capacities. The air inlet and liquid outlet have 1/" NPT (F) connections. The maximum working pressure is 1 psi at 0 F (. bar at ). The 1 features brass fittings and an EPR lid seal. 10 split-eyelet swivel union simplifies installation and maintenance of air atomizing nozzles and spray guns. onnector design reduces costs by eliminating cutting, threading, welding and brazing operations and adjustment of fittings, unions and nipples. Recommended pressure is up to 20 psi (1 bar) for liquid and air lines. Fits 1/2", /" or 1" pipe or similar O.. tube. 1/" NPT or SPT (M) outlet pipe connections. Nickel-plated brass with zinc-plated pipe clamps or all stainless steel construction. 2, 2 level switch kit indicates a low liquid level condition inside the pressure tank. Use standard 2 level switch with and gallon (1 and liter) pressure tank assemblies with external 1/" NPT (F) threads. Use 2 level switch with 1 and 2 gallon ( and liter) pressure tank assemblies with external 1/" NPT (F) threads. Features a U.L. listed float switch, quick disconnect and ' ( m) PV jacketed cable. vailable in brass with una-n float or all stainless steel. tank heater bands provide anywhere from F to F ( to ) heat gain depending upon the tank size and number of bands used. Silicone rubber construction with fiberglass mesh reinforcement for added strength, flexibility, and corrosion resistance. Features quick-release band clasp and built-in thermostat for temperature control. Two sizes fit " and " (2. and. mm) diameter tanks. push-in tube fittings provide fast and easy hook-up of air atomizing nozzles. urable nickel-plated brass construction includes una-n O-ring. Select from six configurations with 1/", 1/" or /" NPT (M) connections for 1/", /" and 1/2" O.. tubing. 2 ferrule-type tube fittings are intended for use when operating at higher pressures. The 1 Stainless Steel is of durable construction and can be easily taken apart for cleaning. Six configurations available with 1/", 1/" or /" NPT connections for 1/", /" and 1/2" O.. tubing. 1 and 2 strong, semi-rigid nylon tubes designed for use with fittings. brasion resistant and dimensionally stable tubing available in ', 2' and 0' (. m,. m and 1 m) lengths. Maximum working pressure is 20 psi (1 bar) at F to 0 F ( to ). 1 has 1/" O.. 2 has /" O.. tomizing Phone spray, FX 1---spray F1

62 tomizing ccessories tomizing 1 10 Pressure tank assembly Split-eyelet swivel union Optimization Tips 2 and 2 and 2 Level switch kit Tube fittings Tank heater bands See lso See page F2 for optimization tips. For 1 pressure tank assembly, request ata Sheet 1 For 10 split-eyelet swivel union, request ata Sheet 10 For 2, 2 level switch kit, request ata Sheet 2 and 2 For tank heater bands, request ata Sheet For, request ata Sheet For 2 ferrule-type tube fittings, request ata Sheet 2 For 1 and 2, request ata Sheets 1 and 2 Phone spray, FX 1---spray F2

CHEMICAL INJECTION PASSIVATING COATING STERILIZING FOGGING HUMIDIFYING MISTING COATING MOISTURIZING GAS COOLING LUBRICATING

CHEMICAL INJECTION PASSIVATING COATING STERILIZING FOGGING HUMIDIFYING MISTING COATING MOISTURIZING GAS COOLING LUBRICATING AIR SPRAY NOZZLES CHEMICAL INJECTION PASSIVATING COATING STERILIZING FOGGING HUMIDIFYING MISTING COATING MOISTURIZING GAS COOLING LUBRICATING C1 AIR NOZZLES INTRODUCTION LARGEST SELECTION OF NOZZLES IN

More information

Low Flow Air Atomizing

Low Flow Air Atomizing XA Low Flow Air Atomizing The XA nozzle system uses the energy in compressed air to produce highly atomized sprays at low flow rates. There are many interchangeable components that can be assembled to

More information

Low Flow Air Atomizing

Low Flow Air Atomizing XA Low Flow Atomizing TO ORDER: specify pipe size, body style, spray set-up #, hardware and mounting assemblies, and material. See page 78. 76 The XA nozzle system uses the energy in compressed air to

More information

Low Flow Air Atomizing

Low Flow Air Atomizing XA Low Flow Air Atomizing TO DER: specify pipe size, body style, spray set-up #, 76 The XA nozzle system uses the energy in compressed air to produce highly atomized sprays at low flow rates. There are

More information

Low Flow Air Atomizing

Low Flow Air Atomizing XA Low Flow Air Atomizing TO DER: specify pipe size, body style, spray set-up #, hardware and mounting assemblies, and material. See page 84. 82 The XA nozzle system uses the energy in compressed air to

More information

AIR ATOMISER NOZZLES. Vapro Series. VP Body 24. VPX/VPL Body

AIR ATOMISER NOZZLES. Vapro Series. VP Body 24. VPX/VPL Body AIR ATOMISER NOZZLES For applications where very fine droplets and low flow rates are required, the air atomiser range from Lurmark, including the VAPRO jet and ULTRA nozzles are the ideal choice. Air

More information

SPRAY CHARACTERISTICS Mist at low pressure; fog at high pressure Spray pattern: Cone-shaped Fog Flow rates: to l/min

SPRAY CHARACTERISTICS Mist at low pressure; fog at high pressure Spray pattern: Cone-shaped Fog Flow rates: to l/min MicroWhirl Fine tomization Outstanding atomization Rugged pinless design Drip-free performance 70 micron polypropylene filter Safety wire hole available Patented design Minimum operating pressure 7 Mist

More information

Hollow Cone Nozzles. Gas cooling Sulfur Burning dust control water aerating chemical Production Cooling m e t a l T r e a t i n g w A S H i n g

Hollow Cone Nozzles. Gas cooling Sulfur Burning dust control water aerating chemical Production Cooling m e t a l T r e a t i n g w A S H i n g Hollow one s Gas cooling ulfur urning dust control water aerating chemical Production ooling m e t a l T r e a t i n g w H i n g gas scrubbing brine spraying product degreasing D1 HOO ON NOZZ INTRODUTION

More information

Section E Fine Spray Nozzles

Section E Fine Spray Nozzles Section E Fine Spray s Overview Our fine spray hydraulic atomizing nozzles are available in two styles. Standard s: Traditional threaded nozzles made of metal. Quick-Connect s: Consisting of a nozzle body

More information

Hollow Cone Nozzles. Gas cooling Sulfur Burning dust control water aerating chemical Production Cooling m e t a l T r e a t i n g w A S H i n g

Hollow Cone Nozzles. Gas cooling Sulfur Burning dust control water aerating chemical Production Cooling m e t a l T r e a t i n g w A S H i n g Hollow one s Gas cooling ulfur urning dust control water aerating chemical Production ooling m e t a l T r e a t i n g w H i n g gas scrubbing brine spraying product degreasing D1 HOO NOZZ INTRODUTION

More information

TYPE AL AIR ATOMISING D.20

TYPE AL AIR ATOMISING D.20 SPRAY CHARACTERISTICS The Delavan AL air atomising series spray nozzles offer the user a wide variety of spray patterns, flow rates and atomisation. Unlike hydraulic or pressurised nozzles where the energy

More information

Model Model 815

Model Model 815 Model 600004 Model 600204 Model 85387 Model 600104 Model 815 ir line products and accessories ir couplers and nipples............................... 196 low guns, tire inflators and siphon sprayers.............

More information

AUTOMATIC SPRAY NOZZLES COATING DISPENSING GLAZING LAMINATING ROBOTIC APPLICATIONS MARKING FLAVORING HUMIDIFYING LUBRICATING MOISTURIZING

AUTOMATIC SPRAY NOZZLES COATING DISPENSING GLAZING LAMINATING ROBOTIC APPLICATIONS MARKING FLAVORING HUMIDIFYING LUBRICATING MOISTURIZING AUTOMATIC SPRAY NOZZLES COATING DISPENSING GLAZING LAMINATING ROBOTIC APPLICATIONS MARKING FLAVORING HUMIDIFYING LUBRICATING MOISTURIZING B1 AUTOMATIC NOZZLES INTRODUCTION INTRODUCTION If your application

More information

Atomizing Spray Nozzles All stainless steel construction for durability and corrosion resistance!

Atomizing Spray Nozzles All stainless steel construction for durability and corrosion resistance! Atomizing All stainless steel construction for durability and corrosion resistance! What Are Atomizing Nozzles? EXAIR s Atomizing atomize fluids (most commonly water) in a range of spray patterns for a

More information

NEW! NEW! Series 3100H HVLP AirSpray Gun HVLP 1 Qt. Cup Siphon Fed Guns Air Requirements: PSI

NEW! NEW! Series 3100H HVLP AirSpray Gun HVLP 1 Qt. Cup Siphon Fed Guns Air Requirements: PSI High Transfer Efficiency AQMD Compliant Ultra-Fine Atomization Precision Fan Control Easy-Clean Gun Body Built-In Cheater Valve Series 3100H HVLP AirSpray Gun HVLP 1 Qt. Cup Siphon Fed Guns Air Requirements:

More information

Section J Air Control Nozzles

Section J Air Control Nozzles Section J Overview Our extensive line of air control nozzles, used in drying and blowing applications, includes products that use regenerative blowers and products that require compressed air. WindJet

More information

JPL Series Air Atomizing Nozzles. Bulletin JPL99C

JPL Series Air Atomizing Nozzles. Bulletin JPL99C JPL Series Atomizing Nozzles Bulletin JPL99C JPL Series Atomizing Nozzles BEX JPL Atomizing Nozzles use compressed air (or gas) to produce an accurately controlled liquid dispersion in applications where

More information

ST/HM. Automatic Spray Gun SERIES FUSO SEIKI CO., LTD. Increased productivity and cost savings by using a lightweight, compact and powerful spray gun

ST/HM. Automatic Spray Gun SERIES FUSO SEIKI CO., LTD. Increased productivity and cost savings by using a lightweight, compact and powerful spray gun F U S O S E I K I C O., L T D Automatic Gun Increased productivity and cost savings by using a lightweight, compact and powerful spray gun ST/HM SERIES FUSO SEIKI CO., LTD. Catalog No. CG-98E-1 Application

More information

Atomizing Spray Nozzles

Atomizing Spray Nozzles Atomizing Atomizing Nozzles All stainless steel construction for durability and corrosion resistance! What Are Atomizing Nozzles? EXAIR s atomizing spray nozzles atomize fluids (most commonly water) in

More information

JPL Series Air Atomizing Nozzles. Bulletin JPL99C

JPL Series Air Atomizing Nozzles. Bulletin JPL99C JPL Series Air Atomizing Nozzles Bulletin JPL99C JPL Series Air Atomizing Spray Nozzles BEX JPL Air Atomizing Spray Nozzles use compressed air (or gas) to produce an accurately controlled liquid dispersion

More information

Leaders in precision application components, control system technology, and application data management.

Leaders in precision application components, control system technology, and application data management. Catalog 51-M Leaders in precision application components, control system technology, and application data management. www.teejet.com Table of Contents Selection Guide TeeJet Broadcast Nozzle Selection

More information

SV1217-SS SPRAY VALVE O P E R AT I N G M A N U A L

SV1217-SS SPRAY VALVE O P E R AT I N G M A N U A L SV1217-SS SPRAY VALVE O P E R AT I N G M A N U A L I&J FISNAR INC. 2003 GENERAL DESCRIPTION The SV1217-SS spray valve is operated by air pressure, providing precise deposit control for low to medium viscosity

More information

Pounds Per Square Inch (PSI)

Pounds Per Square Inch (PSI) Nozzle Size Selection Chart Determine the nozzle size by the pressure washer s GPM @ PSI (gallons per minute @ a specific pounds per square inch). If the nozzle size is too small, your equipment can be

More information

ACCESSORIES 204 ACCESSORIES

ACCESSORIES 204 ACCESSORIES ESSORIES E S S O R I E S rystal Fountains manufactures a select line of water feature accessories. From swivel units to help align spray nozzles to hydraulic fill valves, rystal Fountains manufactures

More information

Spray Nozzle. QuickJet and Systems/Components. Features and Benefits. Accessories

Spray Nozzle. QuickJet and Systems/Components. Features and Benefits. Accessories Efficient QuickJet and Systems are designed to save time in the cleaning and replacement of plugged or worn spray tips. Key feature overview for QuickJet Systems: Reduce maintenance downtime and costs

More information

AIR ASSISTED ATOMIZERS CTG AZ15 BR

AIR ASSISTED ATOMIZERS CTG AZ15 BR IR SSISTED TOMIZERS CTG Z15 BR INTRODUCTION INDEX Page INDEX Introduction - tomizing liquids and air assisted atomizers 1 Properties of an atomized spray 2 Ultrasonic atomizers 3 tomizers and accessories

More information

FRL/AirCare Air Controls & Accessories

FRL/AirCare Air Controls & Accessories FRL/irare ir ontrols & ccessories Lincoln Regulators, Filters & Lubricators well-planned compressed air system ensures minimum pressure loss in the system, and the removal of contaminants: water, compressor

More information

Instrument Ball Valves

Instrument Ball Valves www.swagelok.com Instrument all s 40 Series On-off, switching, and crossover flow paths Working pressures up to 3000 psig (206 bar) Temperatures from 50 to 150 (10 to 65 ) Low-temperature service option

More information

Pneumatic atomizing nozzles ViscoMist flat fan, external mix Series 176

Pneumatic atomizing nozzles ViscoMist flat fan, external mix Series 176 nozzles ViscoMist flat fan, external mix Versatile design with builtin pneumatic needle valve for liquid flow control and automatic clean-out. Three nozzle body configurations offer flexible tailoring

More information

Spray Guns. Choice of Materials and Capacities

Spray Guns. Choice of Materials and Capacities For spot spraying, tree spraying, livestock spraying and power washing at pressures from 30 to 800 PSI. To operate spray gun, handle is rotated 360 from shutoff to maximum flow position. As handle is turned,

More information

RAZOR. RAZOR HVLP Spray Guns

RAZOR. RAZOR HVLP Spray Guns RAZOR RAZOR HVLP Spray Guns Provides generous material flow that helps you get the job done quickly Offers exceptional atomization rate Promotes a superior finish Proven effective for clear coat, base

More information

Pro Xpc. Auto. Automatic Electrostatic Air Spray Guns

Pro Xpc. Auto. Automatic Electrostatic Air Spray Guns Pro Xpc Auto Automatic Electrostatic Air Spray Guns Robot Friendly Graco understands you need to find a lighter, more compact spray gun with greater reach capability. We streamlined the Pro Xpc Auto so

More information

Available in aluminum only. SETTING C STRAIGHT STREAM SPRAY. Maximum Horizontal Throw

Available in aluminum only. SETTING C STRAIGHT STREAM SPRAY. Maximum Horizontal Throw Type 43L & 43H GunJet Spray Guns AA43 GunJet Designed and built for heavy-duty service. Stem extends through extension to valve seat located directly behind orifice disc for drip-free shutoff and instant

More information

TEEJET SWIVELS & 45 NOZZLES BODIES

TEEJET SWIVELS & 45 NOZZLES BODIES TEEJET SWIVELS & 45 NOZZLES BODIES 45 QUICKJET Poly construction Self aligning tip cap Accepts standard twist lock cap, tip & screen Max 125 PSI In MPT Out 5699 1/4" Twist Lock 45 Poly construction nozzle

More information

NOZZLETECH INC. INSTRUCTION MANUAL CEV10 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

NOZZLETECH INC. INSTRUCTION MANUAL CEV10 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA NOZZLETECH INC. 3208C EAST COLONIAL DRIVE ORLANDO, FL 32803 USA INSTRUCTION MANUAL CEV10 01/31/2013 NOZZLETECH CEV10 SERIES COMPACT ELECTRIC VALVES FOR SPRAYING ROUND PATTERNS WARNING: The fluid supply

More information

Optimize Performance and Simplify Installation

Optimize Performance and Simplify Installation ccessories F1 c c e s s o r i e s Introduction Optimize Performance and Simplify Installation Simplify Nozzle Mounting and Positioning Split-eyelet connectors djustable ball fittings djustable hoses and

More information

CJ Series Flat Spray Nozzles For Air & Saturated Steam CJ The following description will help to explain our Part Number/ Code in relation to the SPRAYTECH Spray Nozzle. EXAMPLE ORDERING. SPRAYTECH CJ

More information

CARCO ES-370 AKT Spray Gun The ES-370 AKT Automatic Spray Gun is a production spray gun designed to apply a wide range of marking fluids, including Carco pigmented and dye type marking fluids. CONNECTIONS:

More information

GUNJET NUMBER AA143-AL-*-10 A C A C

GUNJET NUMBER AA143-AL-*-10 A C A C For spot spraying, tree spraying, livestock spraying and power washing at pressures from 2 to 55 bar. To operate spray gun, handle is rotated 360 from shutoff to maximum flow position. As handle is turned,

More information

A GUIDE TO SPRAY TECHNOLOGY FOR THE PULP & PAPER INDUSTRY

A GUIDE TO SPRAY TECHNOLOGY FOR THE PULP & PAPER INDUSTRY A GUIDE TO SPRAY TECHNOLOGY FOR THE PULP & PAPER INDUSTRY COMPREHENSIVE SPRAY TECHNOLOGY SOLUTIONS FROM A SINGLE SOURCE WE LOOK FORWARD TO HELPING YOU OPTIMIZE YOUR OPERATIONS INVOLVING SPRAY TECHNOLOGY.

More information

AirPro Advanced Spraying Technology for Automotive, Metal, Wood, Waterborne, High Wear and Adhesive Applications

AirPro Advanced Spraying Technology for Automotive, Metal, Wood, Waterborne, High Wear and Adhesive Applications AirPro Advanced Spraying Technology for Automotive, Metal, Wood, Waterborne, High Wear and Adhesive Applications AirPro Air Spray Gun Advanced Spraying Technology Whether you are a custom shop or a high

More information

AUTOJET MODEL MODULAR SPRAY SYSTEM AUTOMATIC SPRAY CONTROL MADE SIMPLE

AUTOJET MODEL MODULAR SPRAY SYSTEM AUTOMATIC SPRAY CONTROL MADE SIMPLE AUTOJET MODEL 1550+ MODULAR SPRAY SYSTEM AUTOMATIC SPRAY CONTROL MADE SIMPLE AUTOJET MODEL 1550+ MODULAR SPRAY SYSTEM OPTIMIZES THE PERFORMANCE OF YOUR AUTOMATIC SPRAY NOZZLES BENEFITS Automatic on/off

More information

TUNGSTEN CARBIDE TIPS FOR HIGH-PRESSURE SPRAYING

TUNGSTEN CARBIDE TIPS FOR HIGH-PRESSURE SPRAYING TUNGSTEN CARBIDE TIPS FOR HIGH-PRESSURE SPRAYING TUNGSTEN CARBIDE TIPS SAVE ADHESIVES, COATINGS, PAINT, CHEMICALS & ELECTRICITY In high-pressure spraying applications, the high velocity of the liquid through

More information

INDUSTRIAL SPRAY NOZZLE GUN FOR GENERAL APPLICATIONS LIQUIDS. 143

INDUSTRIAL SPRAY NOZZLE GUN FOR GENERAL APPLICATIONS LIQUIDS.  143 8 INDUSTRIAL SPRAY NOZZLE GUN FOR GENERAL APPLICATIONS LIQUIDS www.charlandthermojet.com 143 T-70 SERIES INDUSTRIAL AUTOMATIC SPRAY NOZZLE GUN Ideal for many cleaning tasks in every kind of industrial

More information

Full cone nozzles. Axial-flow full cone nozzles

Full cone nozzles. Axial-flow full cone nozzles Absorption Chemical process engineering Chlorine precipitation Cleaning Cooling esuperheating ust control Fire protection Foam control Gas treatment ing onto mats in air washers ing over packings Surface

More information

Multiple Nozzle Body Assemblies for Dry Booms

Multiple Nozzle Body Assemblies for Dry Booms Multiple Nozzle Body Assemblies for Dry Booms QJ350 Compact Nozzle Body for Dry Booms n Compact design means easier mounting and less interference with boom structure. n Available with 3 or 5 spray positions

More information

Spray Guns. Trans-Tech, HVLP & Conventional Advanced Technologies for the optimal mix of performance, ergonomics & efficiency

Spray Guns. Trans-Tech, HVLP & Conventional Advanced Technologies for the optimal mix of performance, ergonomics & efficiency Spray Guns P E R F O R M A N C E S E R I E S AUTOMATIC MANUAL TOUCH-UP Trans-Tech, HVLP & Conventional Advanced Technologies for the optimal mix of performance, ergonomics & efficiency www.devilbiss.com

More information

Lances and nozzle headers

Lances and nozzle headers Sanitary Retractable Lances Standard Flanged Lances Tank Cleaning Lances STAMM Showers Pneumatic Atomizing Air Blowoff Quick Disconnect Flat Fan Plastic Specialty 141 Lances Custom fabricated for your

More information

TUNGSTEN CARBIDE TIPS FOR HIGH-PRESSURE SPRAYING

TUNGSTEN CARBIDE TIPS FOR HIGH-PRESSURE SPRAYING TUNGSTEN CRIDE TIPS FOR HIGH-PRESSURE SPRYING TUNGSTEN CRIDE TIPS SVE DHESIVES, COTINGS, PINT, CHEMICLS & ELECTRICITY In high-pressure spraying applications, the high velocity of the liquid through the

More information

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL Read this Instruction Manual carefully and understand it completely, basic precaution should be strictly followed to prevent the damage to the tool and injury

More information

3GR-FSE FUEL. Fuel Pump (High Pressure) Cold Start Fuel Injector *

3GR-FSE FUEL. Fuel Pump (High Pressure) Cold Start Fuel Injector * ENGINE EG 75 General This engine uses the D-4 (Direct injection 4-stroke gasoline engine) system. A (low pressure) fuel pump located inside the fuel tank pumps fuel to the high-pressure fuel pump located

More information

Airspray Technology. Concept and Theory Training

Airspray Technology. Concept and Theory Training Concept and Theory Training Table of Contents Introduction...1 Module Overview...1 How to Use This Module...1 Airspray Fundamentals...3 Learning Objectives...3 Airspray Atomization...3 Principal Parts

More information

Self-Acting Temperature Control Valve

Self-Acting Temperature Control Valve GLOE & NEELE Northeast ontrols Inc. Tel: 8454183435 Fax: 8455952471 www.dwyerstore.com Selfcting Temperature ontrol Valve Require No External Power Selfcting Temperature ontrol Valves require no external

More information

COMPACT REELS FOR BOOSTER HOSE To handle single 3/4" I.D. or 1" I.D. hose.

COMPACT REELS FOR BOOSTER HOSE To handle single 3/4 I.D. or 1 I.D. hose. OMPT RLS OR OOSTR OS To handle single 3/4" I.. or 1" I.. hose. hoose direct crank rewind (removable) or chain and sprocket drive powered by electric, hydraulic or compressed air motor. Power rewind supplied

More information

For Applications Demanding Precision and Efficiency, FloMax Nozzles Outperform All Others

For Applications Demanding Precision and Efficiency, FloMax Nozzles Outperform All Others Nozzles Control Analysis Fabrication FloMax Air Atomizing Nozzles Unique Atomization Process Provides Unmatched Efficiency in Gas Conditioning Operations For Applications Demanding Precision and Efficiency,

More information

Binks MACH 1SL HVLP SPRAY GUN Mach 1SLA (Adjustable Fluid Inlet) & Mach 1SLV (Vitreous)

Binks MACH 1SL HVLP SPRAY GUN Mach 1SLA (Adjustable Fluid Inlet) & Mach 1SLV (Vitreous) Binks MACH 1SL HVLP SPRAY GUN Mach 1SLA (Adjustable Inlet) & Mach 1SLV (Vitreous) The Binks MACH 1SL HVLP Gun is a top quality high performance air spray gun. You only have to pick it up to feel the difference.

More information

Section H Spray Guns. Table of Contents

Section H Spray Guns. Table of Contents Section H Overview You re sure to find a solution for your cleaning and rinsing needs in our comprehensive line of hand-held spray guns. Options range from a gentle spray to a high-impact solid stream.

More information

Parts and Accessories

Parts and Accessories Parts and Accessories For a full list of available pressure washer parts and accessories, visit www.landa.com. 1150 Davis Road, Suite J Elgin, IL 60123 (800) 788-8867 info@lorchem.com www.lorchem.com Hypro

More information

HANNAY REELS. Spray Hose Reels. The reel leader. Reels to handle hose for: Grounds Maintenance Pest Control Vehicle Maintenance Steam Cleaning

HANNAY REELS. Spray Hose Reels. The reel leader. Reels to handle hose for: Grounds Maintenance Pest Control Vehicle Maintenance Steam Cleaning Spray ose Reels NNY RLS The reel leader. Reels to handle hose for: rounds Maintenance Pest ontrol Vehicle Maintenance Steam leaning Lawn are Service Tree Spraying eneral Maintenance griculture -9450-S

More information

UNI-SPRAY - CLAMP-ON NOZZLE SELECTION GUIDE -

UNI-SPRAY - CLAMP-ON NOZZLE SELECTION GUIDE - UNI-SPRAY - CLAMP-ON NOZZLE SELECTION GUIDE - Uni-Spray Nozzles... are injection molded from custom blended polypropylene, a cost effective material that is corrosion and heat resistant and is impervious

More information

Shaft No. of Part # Old No. Model No. Housing Rotation dia Rollers Seals. NOTE: CI = Cast-Iron, N = Ni-Resist, SL = Silver Last

Shaft No. of Part # Old No. Model No. Housing Rotation dia Rollers Seals. NOTE: CI = Cast-Iron, N = Ni-Resist, SL = Silver Last Hypro Roller Pumps Ideal for farm sprayers, pest control and chemical application usage. Housings available in cast-iron, Ni-resist or silver series Self-priming operation; roller pumps should not be run

More information

Full cone nozzles.

Full cone nozzles. nozzles Absorption Chemical process engineering Chlorine precipitation Cleaning Cooling esuperheating ust control Fire protection Foam control as treatment ing onto mats in air washers ing over packings

More information

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX: TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: +353 66 7121911 FAX: +353 66 7124503 e-mail: sales@tillotson.ie HU SERIES SERVICE MANUAL INTRODUCTION To keep apace of new market

More information

NOZZLE TYPES AND CHARACTERISTICS

NOZZLE TYPES AND CHARACTERISTICS 95 NOZZLE TYPES AND CHARACTERISTICS Dennis w. Bintner Design Engineer Delavan Hanufacturing Company West Des Moines, Iowa The many varieties of herbicides on the market today, make the proper selection

More information

Shaft Adapter (5/8 to 3/4 ) NOTE CI = Cast Iron, N = Ni-Resist, SL = Silver Last. Series Series 7560

Shaft Adapter (5/8 to 3/4 ) NOTE CI = Cast Iron, N = Ni-Resist, SL = Silver Last. Series Series 7560 Your One Stop Shop for Parts Hypro Roller Pumps Ideal for Farm Sprayers, Pest Control and Chemical Application Usage. Housings available in Cast Iron, Ni-Resist or Silver Series Self priming operation;

More information

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico: MicroCoat System Operating Manual MC2 Series MC785, MC785-WF Spray Valves A NORDSON COMPANY US: 8-498-8865 UK: 8 585733 Mexico: 1-8-556-3484 Introduction The MicroCoat System provides precise lubrication

More information

HVLP Spray Guns HVLPR-5 5/06

HVLP Spray Guns HVLPR-5 5/06 HVLP Spray Guns HVLPR-5 5/06 HVLP Spray Guns Table of Contents About HVLP............................. 3 MACH 1 HVLP System Features and Benefits.................... 4 Standard Fluid and Air Nozzle Selection

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

Spray Equipment for Every Purpose Industrial Selection Guide

Spray Equipment for Every Purpose Industrial Selection Guide Spray Finishing Equipment Selection Guide A98-142R Spray Equipment for Every Purpose Industrial Selection Guide Choosing a Spray Outfit is as easy as 1 2 3! 1 Paint Usage Per Day Getting Paint to the Spray

More information

,, WY VLVS Way Valves - Side ntry Product index... p. - Way Valves - ottom ntry Product index... p. Way Valves - ottom ntry Product index...p. ontents

,, WY VLVS Way Valves - Side ntry Product index... p. - Way Valves - ottom ntry Product index... p. Way Valves - ottom ntry Product index...p. ontents MTRI,, WY VLVS 6P/6P SRIS ,, WY VLVS Way Valves - Side ntry Product index... p. - Way Valves - ottom ntry Product index... p. Way Valves - ottom ntry Product index...p. ontents Introduction... Page - Product

More information

Spring Return and Double Acting Pneumatic Quarter- Turn Actuators For Output Torques to 13,444 lb.in.

Spring Return and Double Acting Pneumatic Quarter- Turn Actuators For Output Torques to 13,444 lb.in. Spring Return and ouble cting Pneumatic Quarter- Turn ctuators For Output Torques to 13,444 lb.in. Features and benefits ompact rack and pinion design utilizes the whole piston area to develop output torque.

More information

Automotive Spray Gun Equipment Selection Guide

Automotive Spray Gun Equipment Selection Guide Automotive Spray Gun Equipment Selection Guide www.binks.com www.devilbiss.com 77-5920 Selecting The Right Equipment It s Critical to Use the Right Equipment for Each Application Using the right equipment

More information

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX: TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: +353 66 7121911 FAX: +353 66 7124503 e-mail: sales@tillotson.ie HS SERIES SERVICE MANUAL INTRODUCTION The demand for a miniature

More information

AutoJet Lubrication Systems

AutoJet Lubrication Systems AutoJet Lubrication Systems AutoJet Lubrication Systems AutoJet Lubrication Systems provide a highly efficient method of applying lubricants and corrosion protection fluids. In addition to lubricating

More information

Flow Controls & Accessories

Flow Controls & Accessories Flow ontrols & ccessories Section Flow ontrol Valves SPF Series...2 337 Series...3 3250 Series... 4-5 Right ngle Series... 6-9 Needle Valves SPN Series...10 338 Series...11 SP Series heck Valve...12 339

More information

RAINING DIVISION. Equipment Selection for the Painting Contractor

RAINING DIVISION. Equipment Selection for the Painting Contractor RAINING DIVISION Equipment Selection for the Painting Contractor 1. THE APPLICATION: Assuming that a spray process is selected as the best method for the application of a coating, then the selection of

More information

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX: TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: +353 66 7121911 FAX: +353 66 7124503 e-mail: sales@tillotson.ie SERIES SERVICE MANUAL INTRODUCTION The gasoline engine industry

More information

W94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection

W94. Specifications. Protection: Models Temperature Range Capillary Length Sensing Bulb Valve Body Selection Temperature Model W91 (No Indicating Dial) W94 (Temperature Indicating Dial) Service Water, Steam, Other Liquids Sizes 1/2 4 onnections Threaded, Union Ends, 125# FLG 250# FLG (optional) ody Material 1/2

More information

Quick-disconnect spray nozzles

Quick-disconnect spray nozzles ZIP-TIP Quick-disconnect spray nozzles + = ZIP-TIP BODY STNDRD O-RINGS ZIP-TIP TIP COMPETE UNIT BEX ZIP-TIP quick-disconnect spray nozzles are designed to allow fast and easy installation and removal of

More information

ADJUSTING PRESSURE USING THE BOOM NOZZLES OPERATION

ADJUSTING PRESSURE USING THE BOOM NOZZLES OPERATION 6. The pressure gauge is shipped in a parts bag. Thread the gauge into the tee fitting as shown on the exploded view drawing. Use a good quality thread sealant to prevent leaks. The in-line switch turns

More information

Binks Model 95 SPRAY GUN

Binks Model 95 SPRAY GUN Binks Model 95 SPRAY GUN Model 95 Signature Series Spray Gun This handheld gun is the premier spray gun in the Binks line. A combination of the three best industrial spray guns, Model 95 sets a new standard.

More information

Gun. Silver Plus. Lightweight, Rugged Design. Exclusive Needle Design. 2-Finger Trigger Design and Handle. Stainless Steel Fluid Tube

Gun. Silver Plus. Lightweight, Rugged Design. Exclusive Needle Design. 2-Finger Trigger Design and Handle. Stainless Steel Fluid Tube Silver Plus Gun The Silver Plus Airless Gun is known for its durability, long life, spraying performance and comfortable design. It is the preferred gun for high pressure applications. Lightweight, Rugged

More information

CASH VALVE B SERIES PRESSURE REGULATORS

CASH VALVE B SERIES PRESSURE REGULATORS Single seated, spring loaded, direct acting diaphragm-type pressure reducing and regulating valves for a broad range of services FEATURES Reduce high inlet pressures to lower outlet pressures within close

More information

Your Global Source for Today s Most Popular Solenoid Valves

Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves Your Global Source for Today s Most Popular Solenoid Valves lcon Solenoid Valves, a division of International

More information

SIMPLE INTERCTIVE DECK JETS S I M P L E I N T E R C T I V E N O Z Z L E S N o n - S e q u e n c i n g / C o n s t a n t F l o w While choreographed water features can be exciting, similar effects can be

More information

Low shear, low pulsation performance delivers superior finish quality

Low shear, low pulsation performance delivers superior finish quality TRITON 3:1 irculating Pumps TRITON 13HP 23375 & 233751 TRITON 38HP 23385 & 233816 Low shear, low pulsation performance delivers superior finish quality FETURES ND ENEFITS Low pulsation output provides

More information

Pneumatic rotary drive

Pneumatic rotary drive Pneumatic rotary drive Modular program for mounting of quarter turn valves such as ball valves and butterfly valves NMUR and ISO 5211 interfaces Position feedback (including Ex-Versions) Type 2051 can

More information

Carter Pressure Loss Compensator and Venturis. Model Model Model Model Model 64086

Carter Pressure Loss Compensator and Venturis. Model Model Model Model Model 64086 Carter Pressure Loss Compensator and Venturis Model 60559 Model 64088 Model 64085 Model 64193 Model 64086 esign Concepts Eaton s Carter product line includes Model 60559 Pressure Loss Compensator and a

More information

Right Angle Nozzle Assembly

Right Angle Nozzle Assembly Swirl- Air atomizing nozzle Features: Large internal passages with no vanes or cores assure unrestricted flow... Little chance for clogging No external struts or supports to interfere with spray pattern

More information

Binks Model 2001 AND 2001V SPRAY GUNS

Binks Model 2001 AND 2001V SPRAY GUNS Binks Model 2001 AND 2001V SPRAY GUNS 1 2 3 4 Your new Binks spray gun is exceptionally rugged in construction, and is built to stand up under hard, continuous use. However, like any other fine precision

More information

Carburetor Instructions

Carburetor Instructions Carburetor Instructions for HUDSON SUPER SIX ESSEX SIX CYLINDER Hudson Motor Car Co. DETROIT, U.S.A. Carburetor The carburetor is a device for metering correct amounts of fuel and air for the various

More information

Pounds Per Square Inch (PSI)

Pounds Per Square Inch (PSI) Nozzle Size Selection Chart Determine the nozzle size by the pressure washer s GPM @ PSI (gallons per minute @ a specific pounds per square inch). If the nozzle size is too small, your equipment can be

More information

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves MicroCoat System Operating Manual MC Series MC785M, MC785M-WF Spray Valves A NORDSON COMPANY Introduction The MicroCoat System provides precise lubrication control for metal stamping operations. The MC

More information

OPTIMIZE PERFORMANCE AND SIMPLIFY INSTALLATION

OPTIMIZE PERFORMANCE AND SIMPLIFY INSTALLATION ACCESSORIES G1 A C C E S S O R I E S INTRODUCTION OPTIMIZE PERFORMANCE AND SIMPIFY INSTAATION Clog Prevention iquid strainers Filtration assemblies Air line filters Ensure Proper Flow Control and Regulation

More information

MACH 1A HVLP (MACH 1AV HVLP) Automatic Airspray Gun

MACH 1A HVLP (MACH 1AV HVLP) Automatic Airspray Gun MACH 1A HVLP (MACH 1AV HVLP) Automatic Airspray Gun Your new Binks MACH 1A HVLP Automatic Spray Gun is exceptionally rugged in construction, and is built to stand up under hard, continuous use. However,

More information

OPTIMIZE PERFORMANCE AND SIMPLIFY INSTALLATION

OPTIMIZE PERFORMANCE AND SIMPLIFY INSTALLATION ACCESSORIES G1 A C C E S S O R I E S INTRODUCTION OPTIMIZE PERFORMANCE AND SIMPIFY INSTAATION Clog Prevention iquid strainers Filtration assemblies Air line filters Ensure Proper Flow Control and Regulation

More information

VG4000 Series. High-Capacity/High-Closeoff Electric Zone Valves

VG4000 Series. High-Capacity/High-Closeoff Electric Zone Valves Product ulletin VG000 Issue ate 11/01/01 VG000 Series High-apacity/High-loseoff Electric Zone Valves VG000 Series High-apacity/High-loseoff Electric Zone Valves are designed to regulate the flow of water

More information

Flat Fan Nozzles. Flat Fan nozzles can be used fo washing, rinsing and surface treatments including high pressure nozzles used at up to 200 bar.

Flat Fan Nozzles. Flat Fan nozzles can be used fo washing, rinsing and surface treatments including high pressure nozzles used at up to 200 bar. vailable in a wide range of spray angles and flows. Liquid is forced through an oval or eliptical orifice to form a sheet of spray that breaks into ligaments and then droplets or is atomised by impacting

More information

GREEN GARDE MODEL JD9-C - HIGH PRESSURE SPRAY GUN

GREEN GARDE MODEL JD9-C - HIGH PRESSURE SPRAY GUN GREEN GARDE MODEL JD9-C - HIGH PRESSURE SPRAY GUN Guns Spray 38500 Model JD9-C - 38500 The JD9 heavy-duty spray gun can help make your operation more effective and profitable. Check these advantages. Adjustable

More information

IRRIGATION SUPPLIES. Kifco Water Reels. CONSERV FS IS AN AUTHORIZED KIFCO DEALER Repair Parts Available

IRRIGATION SUPPLIES. Kifco Water Reels. CONSERV FS IS AN AUTHORIZED KIFCO DEALER Repair Parts Available Kifco Water Reels KIFCO: DESIGNED TO MAKE PORTABLE IRRIGATION EASY! Kifco Water-Reels are designed to make portable irrigation easy. The machines are simple to operate and provide efficient irrigation

More information